1. 95 Green Street (COFA-08-24-019275): A request Glenda Mikulak Roberts (Applicant and
Owner) for review of a Certificate of Appropriateness - HD to construct a new 2-story house of
approximately 1,987 SF at 95 Green Street, in the OId Town Bluffton Historic District and
zoned Neighborhood General-HD. This is a second Concept Plan review. (Staff - Charlotte
Moore)
VI. DISCUSSION
VII. ADJOURNMENT
NEXT MEETING DATE: Monday, March 2 , 2026
Page 1
Town of Bluffton, SC Historic Preservation Review Committee Meeting Agenda February 23, 2026
“FOIA Compliance – Public notification of this meeting has been published and posted in compliance
with the Freedom of Information Act and the Town of Bluffton policies.”
In accordance with the requirements of Title II of the Americans with Disabilities Act of 1990 ("ADA"), the
Town of Bluffton will not discriminate against qualified individuals with disabilities on the basis of
disability in its services, programs, or activities. The Town of Bluffton Council Chambers are ADA
compatible. Auditory accommodations are available. Any person requiring further accommodation
should contact the Town of Bluffton ADA Coordinator at 843.706.4500 or
adacoordinator@townofbluffton.com as soon as possible but no later than 48 hours before the
scheduled event.
Executive Session – The public body may vote to go into executive session for any item identified for
action on the agenda.
*Please note that each member of the public may speak at one public comment session and a form must
be filled out and given to the Town Clerk. To submit a public comment online, please click here:
https://www.townofbluffton.sc.gov/FormCenter/Town-15/Public-Comment-60
Public comment is limited to 3 minutes per speaker.
Page 2
Page 1 of 3
Growth Management Comments
1) Square Footage: The main house is shown as 1,987SF. This does not include the
half-story square footage which is identified as an unfinished loft. The loft square
footage must be included in the overall square footage even if it is not heated.
2) Sections: Label all materials and dimensions on all wall sections.
3) First Floor and Porch Height: Finished floor height must be a minimum of 3’-0”
above the average adjacent sidewalk grade (UDO Sec. 5.15.5.F.1.c.) and the porch
must be at least 30-0” above the average grade (UDO Sec. 5.15.6.E.5). Because they
are lower (2’-0” and 1’-7”, respectively), the Green Street elevation seems awkward.
Piers are just 1’-2” in height. Railings and handrails are unnecessary at this height;
consider removing.
4) Front Porch Columns: Six columns seem excessive, especially with a width of one
foot.
5) Chimney: The chimney is disproportionately large for the scale of the main
residence. Decrease the width and consider applying two smaller bishop’s caps
instead of a single, large bishop cap. the chimney cap must not be visible from the
street. (UDO Sec. 5.15.6.E.8)
6) Building Walls: Gables on left elevation show the rear gable with board and batten
and the right gable with horizontal lap siding. Change the left gable to match the right
gable.
7) Trim: Some trim details are identified as Azek and others are “Hardie Plank or Azek”.
Azek is not an approved material in the UDO and will require a determination by HPC
(UDO Sec. 5.15.6.G.3). Where details state “Hardie Plank or Azek”, specify one
material.
Page 3
Section V. Item # 1.
Page 2 of 3
8) Windows: Window material has not been identified. The application references
“clad.” The window schedule includes the manufacturer’s name and window names,
but materials aren’t identified (UDO Sec. 5.15.6.I.) Additionally, certain windows are
fixed, which is not a permitted configuration (e.g., middle dormer window on the front
elevation; the window above the living plant wall is unclear). There are also two long
windows on both sides of the French door on the left elevation which are fixed.
9) Doors: Doors are identified as “clad” but material is not provided. Update door
schedule to reflect a material permitted by UDO 5.15.6.I.2.b.
10) Roof: Roofing materials are currently labelled as “varies”. The application notes that
“fiberglass shingles” are proposed, yet standing seam metal is also proposed for the
shed roof at the porch and the dormers. Revise to accurately reflect roofing material
based on a permitted material in UDO Section 5.15.6.J.2.
11) Skirting & Underpinning: Skirting is proposed but the application shows “n/a” for
material, configuration, and dimensions. Label materials and dimensions on plans
and update application when resubmitting. Material and placement must be
consistent with UDO Sec. 5.15.6.O.
12) Soffit: Add soffit configuration on wall section (sheet 1/A4.2). Soffits should be
beaded or v-groove tongue & groove (UDO Sec. 5.15.6.P.5). Preliminary application
states “n/a” for soffit details.
13) Pavers: Provide manufacturer cut sheet for proposed tabby pavers.
14) Final Submission: The drawings must be revised for the Final Plan submission to the
HPC. With the Final Plan, provide a written response to these comments, as well as
all items noted in the COFA application checklist. Include dimensions and materials
for all building elements. Systems information is unnecessary. The Final Plan will not
be scheduled for the HPC until such time as a complete application is provided.
HPRC Comments
1) Sections: Clarify which part of the main residence is being depicted in Typical Wall
Section 2.
2) Porches: On the front elevation, bring the header on the right side of the porch down
to be even with the left elevation header or bring the entire porch roof down. The
current conformation makes it look too tall.
3) Walls: The rear elevation wall is too flat and should have some relief, rather than one
long, straight wall.
4) Windows: a) Elongate the front elevation window (pantry window) to match the
dimensions of the laundry/entry room window. b) The windows underneath the
gables on the front elevation are too small for the space. Consider adding shutters or
Page 4
Section V. Item # 1.
Page 3 of 3
replacing them with double windows; and, c) Consider adding another window on the
rear elevation to break up blank wall.
Page 5
Section V. Item # 1.
Source: Town of Bluffton website. First collected Nov 7, 2026.