BOA-24 -40, 550/552 Brushwood Dr. (City)
The applicant (JMJ Homes, LLC) is requesting a variance from
the front setback requirements outlined in the Sumter West
Planned Development Ordinance (Ordnance # 2857, PD-00-08,
Revision 26) in order to allow for single-family attached
structure (consisting of 2 dwelling units) to be established +/-
24.37 ft. from the front property line. The Sumter West
Planned Development Ordinance requires a 25 ft. front building
setback on this property. Planned Developments in general are
authorized by Article 3.p: Planned Development (PD) District of
the City of Sumter Zoning & Development Standards
Ordinance. The property is located at 550/552 Brushwood Dr.,
is zoned Planned Development (PD), and is identified as TMS#
185-00-01-186.
2
Sumter City-County
Zoning Board of Appeals
December 11, 2024
BOA- 24-40, 550/552 Brushwood Dr. ( City)
I. THE REQUEST
Applicant: JMJ Homes, LLC
Status of the Applicant: Property Owner
Request: Variance to front setback requirements for a new single -family
attached residential structure.
City Council Ward: Ward 5
Location: 550/552 Brushwood Dr.
Present Use/Zoning: Residential (Under Construction) / Planned Development (PD)
Tax Map Reference: 185-00-01-186
II. B ACKGROUND
The applicant is requesting a variance to
the front setback requirements outlined in
the Planned Development Ordinance for
Sumter West. Sumter West is a mixed use
Planned Development originally
established in 2000.
The subject property is shown in red on
the location map to the right and is
located on the west side of Brushwood
Dr. at a midblock location between the
intersections of Brushwood
Dr./Constitution Dr. and Brushwood Dr./
Declaration Blvd.
In 2019, City Council adopted a revised Planned Development Ordinance for Sumter West to
allow for townhome ( two-unit single-family attached) lots to be established in certain areas of
the Planned Development designated as neighborhood commercial. This revised Ordinance
3
included specific development standards for townhome construction in this area, including a
required 25 ft. front building setback.
Figure 1: Sumter West PD Concept Plan
Figure 2: Approved Neighborhood Commercial Townhome Area
4
Building permits were issued for the c onstruction of the townhome structure, containing 2
separate dwelling units, on March 6, 2024. Issued permits contained information on basic
development standards, including required building setback requirements and approved plans .
The primary building permits issued for this project are attached to this report as Exhibit 1.
Since the development is a townhome, a property line is set along the shared common wall
be
tween the units. The property line is established after construction is underway once a firm
location for the shared wall is established. Based on the plat submitted to split the lot, it was
discovered that the structure encroached into the front setback by 0.63 ft. at the point closest to
the front property line. The plat submitted was prepared by Andersen Land Surveying (Job#
24225), is dated November 1, 2024, and is attached to this report as Exhibit 2. The applicant is
requesting variance approval, citing the street curvature as a primary hardship, to resolve the
setback encroachment.
Figure 3: Plat Showing Front Setback Encroachment
5
Site Photo: Front View of Townhome Structure From Brushwood Dr.
Ordinance Requirements:
City Ordinance# 2857 (PD-008, Revision 26) – Section I.B.vii – Townhouse Development
within the Commercial Area (Brushwood & Constitution Drives)
vii. Townhouse Development within the Commercial Area (Brushwood & Constitution Drives) – A maximum
of 56 units in 28 structures.
a. Setbacks:
i. Front – 25 ft.
ii. Si des – 8 ft. with an option of 5 ft. on side of choice. If the townhouse structure
is deeded separately a 0 ft. setbacks line shall be allowed on the shared interior
property line.
iii. Rear – 20 ft.
b. Maximum Height – 35 ft.
The Request:
The applicant is requesting is requesting a variance from the front setback requirements outlined
in the Sumter West Planned Development Ordinance (Ordnance # 2857, PD-008, Revision 26)
in order to allow for single -family attached structure (consisting of 2 dwelling units) to be
established +/- 24.37 ft. from the front property line. The Sumter West Planned Development
Ordinance requires a 25 ft. front building setback on this property. Planned Developments in
general are authorized by Article 3.p: Planned Development (PD) District of the City of Sumter Zoning
& Development Standards Ordinance.
6
III. FOUR PART TEST
In order to grant the requested variance, the request must meet all parts of a State-mandated four-
part test. When reviewing a variance request, the Board may not grant a variance that would do
the following:
• Allow the establishment of a use not otherwise permitted in a zoning district;
• Extend physically a nonconforming use of land;
• Change zoning district boundaries shown on the Sumter City- County Official Zoning
Map.
The fact a property may be utilized more profitably should a variance be granted shall not be
considered grounds for approving a variance request. In granting a variance, the Board may
attach to it such conditions regarding location, character, or other features of the proposed
building, structure, or use as the Board may consider advisable to promote the public health,
safety, or general welfare.
Staff Review:
1) There are extraordinary and exceptional conditions pertaining to the particular piece of
property.
The property is located at 550/552 Brushwood Dr. and is part of the approved neighborhood
commercial townhome area of the Sumter West Planned Development. The property
received building permit approval for the construction of a 2-unit townhome structure. Prior
to completion of the structure, the property is to be subdivided along the shared wall between
the 2 units. The plat submitted to subdivide the property shows a front setback encroachment
of 0.63 ft. at the closest point. The property has frontage along a moderately curved section
of Brushwood Dr.
2) These conditions do not generally apply to other property in the vicinity.
As it relates to a request for a front setback variance, the property generally shares similar
characteristics as other approved neighborhood c ommercial area townhome lots. Staff notes
that there is a slight curvature along Brushwood Dr. right -of-way where the subject property
sits. This is not a characteristic shared by a majority of the aforementioned townhome lots.
All such lots are subject to the 25 ft. front setback requirement.
3) Because of these conditions, the application of the ordinance to the particular piece of
property would effectively prohibit or unreasonably restrict the utilization of the property.
The situation prevents the applicant from receiving zoning final inspection approvals
necessary to receive a Certificate of Occupancy.
7
4) The authorization of a variance will not be of substantial detriment to adjacent property or
to the public good, and the granting of the variance will not harm the character of the
district.
The amount of setback variance (0.63 ft.) being requested is minor and approval is not
anticipated to result in substantial determinant to adjacent property or the public good.
Additionally, approval is not anticipated to harm the character of the neighborhood
commercial townhome area with the Sumter West Planned Development.
IV. STAFF RECOMMENDATION
The purpose of regulating structure setbacks is to ensure compatibility , ensure minimum open
space around a structure, facilitate safe access, and avoid negatively impacting surrounding
properties. Deviations from the Ordinance specified requirements should be carefully weighed.
Staff recommends no additional approval conditions if t
he BOA makes the necessary findings to
the approve this request.
V. DRAF
T MOTIONS FOR BOA-24-40
1. I move the Zoning Board of Appeals approve BOA-24-40, subject to the findings of fact
and conclusions developed by the BZA and so stated:
2. I
move the Zoning Board of Appeals deny BOA-24-40, subject to the following findings
of fact and conclusions:
3.
I move the Zoning Board of Appeals enter an alternative motion for BOA-24-40.
VI. BOARD OF APPEALS – December 11, 2024
Exhibit 1
Exhibit 2
Source: City of Sumter website. First collected Nov 7, 2026.