Historic District Review Board Meeting (Agenda Packet)
City of Beaufort · Beaufort County · meeting of May 14, 2025 · Agenda packets
Open the original document More from City of Beaufort
Text
Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.
MEETING AGENDA
The City of Beaufort
HISTORIC DISTRICT REVIEW BOARD
Wednesday, May 14, 2025, 2:00 P.M.
City Hall, Council Chambers, 2nd Floor – 1911 Boundary Street, Beaufort, SC
Please click the link below to access the webinar:
https://us02web.zoom.us/j/89760823279?pwd=DucPfYf73P7LshCar3VjadmgmKak2b.1
Password: 405196 Meeting ID: 897 6082 3279 Call in Phone #: 1+929 205 6099
STATEMENT OF MEDIA NOTIFICATION: “In accordance with South Carolina Code of Laws,
1976, Section 30-4-80(d), as amended, all local media were duly notified of the time, date, place, and agenda
of this meeting.”
Note: A project will not be reviewed if the applicant or representative is not present at the meeting.
I. Call to Order:
II. Review of Minutes:
A. April 9, 2025 Meeting Minutes
III. Applications
A. 1203 Bay Street (The Cuthbert House), PIN R120 004 000 771A 0000, awning replacement
Applicant: Chris Ramm, Owner
The applicant is requesting approval for replacement of a green canvas awning at the rear of The
Cuthbert House with a standing seam metal shed roof.
B. 1107 Prince Street, PIN R120 004 000 0503 0000, alterations, additions
Applicant: Benjie Morillo, Architect, Frederick + Frederick Architects
The applicant is requesting approval to partially demolish the existing structure, enclose the existing
porch and add a new screened porch and terrace .
IV. Discussion
V. Adjournment
1
Historic District Review Board
Meeting Minutes – April 9, 2025
CALL TO ORDER 0:18
A meeting of the Historic District Review Board was held in-person on Wednesday, April 9, 2025 at 2:00
pm.
ATTENDEES
Members in attendance: Mike Sutton (Chair), Eric Berman, (Vice-Chair), and Rita Wilson.
Member absent: Grady Woods
Member late: Kim Petrella
Staff in attendance: Curt Freese, Community Development Director, Christopher Klement, Community
Development Planner, III, Nick Navia, Community Development Planner, I, Meadors Architects, and Julie A.
Bachety, Community Development Administrative Assistant II.
REVIEW OF MINUTES OF MARCH 12, 2025 0:40
Motion: Ms. Wilson made a motion to approve the March 12, 2025 minutes as submitted. Mr. Berman
seconded the motion. The motion passed unanimously.
All Historic District Review Board Meeting minutes are recorded and can be found on the City’s website at
http://www.cityofbeaufort.org/AgendaCenter.
APPLICATIONS 1:15
A. 914 Newcastle Street, PIN R120 004 000 0279 0000, new construction
Applicant: Megan Chancellor Crumrine, Chancellor Design, LLC
The applicant is requesting approval for a single-family residential dwelling unit.
Christopher Klement presented the staff report.
Public Comment:
Lise Sundrla, Historic Beaufort Foundation (HBF), stated the Preservation Committee feels it is
2
an overscale structure, but they feel the breakup of the massing and scale were done very
successfully. The only thing HBF recommends is lowering the garage.
Fred Washington, Jr., resides at 804 West Street, has an interest in Washington Street Park
across the street which is going to be an active park with a pavilion that is under construction
now that will allow for parties, plays, and other gatherings. Something of this size is not normal
in the Northwest Quadrant. He is concerned with the drainage issues does not want it to
intrude into the park. He likes the idea of screening. He asked that the builders be sensitive to
those other activities and facilities that are in the area now.
Jeremiah Smith resides at 1107 West Street, said he lives 4 blocks from the area, and he brings
his kids to the park. He thinks the massing would be helpful to help define that the park is right
there. Our streets are so wide, so people go fast. This would help make our streets feel like
spaces. It’s only 59% lot coverage which is not a lot.
Public comment closed.
Motion: Mr. Berman made a motion to approve preliminary to the project as the staff
conditions are written with the following:
o Eliminate staff condition #1a;
o Staff recommendations 1b – 1e will be combined into a condition to review as a 9’1”2
roof in addition to the 6” reduction for the main structure that was proposed;
o Conquer with staff recommendations 2, 3, 4, and 5; and
o Eliminate staff condition #6.
Ms. Wilson seconded the motion. The motion passed unanimously.
B. 909 Washington Street, PIN R120 004 000 0304 0000, accessory dwelling unit 50:52
Applicant: Nicole Gilmore, owner
The applicant is requesting approval for a carriage house in the rear of the property.
Kim Petrella joined the meeting at this time.
Nick Navia presented the staff report.
Public Comment:
Lise Sundrla, Historic Beaufort Foundation (HBF), confirmed the applicant did clarify that it is
going to be stucco. The Preservation Committee felt comfortable with horizontal windows
versus the two over two that staff recommended. It’s a good plan.
Jeremiah Smith resides at 1107 West Street, spoke about the overall size and doesn’t think the
50% rule is a good one. For example, removing the rear porch doesn’t help anybody. No one
will know from the street, and they will have less outdoor space.
Fred Washington, Jr., resides at 804 West Street, owns property behind the proposed
development at 910 Greene Street which was given preliminary approval for an accessory
dwelling unit (ADU) and his two sisters that own the property on the right of the property at 905
3
Washington Street which also has an ADU. He is concerned with the sitting of the building itself,
and wants to make sure it’s not too close to the property. He asked if there would be any
screening specifically by his sisters’ property for privacy.
Public comment closed.
Motion: Mr. Berman made a motion to grant final approval with the following conditions based
on what are in the staff recommendations:
#1 - Windows will be one over one;
#2 - As stated;
#3 - As stated;
#4 - Wood or fiberglass windows as the applicant stated; and
#5 – Eliminate this condition and leave the footprint as is.
And whatever cutsheets or colors are not mentioned that those are to be provided to staff
for final approval.
Ms. Wilson seconded the motion.
Mr. Sutton clarified that for the applicant to get final, she will need to get the administrative
adjustment from staff, cut sheets on the windows and to look at the stucco finish to make sure
its cementitious stucco to match the existing building.
The motion passed unanimously.
C. 701 Greene Street, PIN R120 004 000 1042 0000, alterations 1:25:43
Applicant: Jeremiah Smith, Allison Ramsey Architects, Inc.
The applicant is requesting approval for a brick wall and hedge and a stair down from the
existing rear porch for access to the wall garden.
Christopher Klement presented the staff report.
Public Comment:
Lise Sundrla, Historic Beaufort Foundation (HBF), said overall the Preservation Committee are
in full support and the stairs on the rear porch work well.
Public comment closed.
Motion: Ms. Wilson made a motion to approve as presented. Mr. Berman seconded the
motion. The motion passed unanimously.
D. 602 Bladen Street, PIN R120 003 000 0215 0000, new construction 1:25:43
Applicant: Cooter Ramsey, Allison Ramsey Architects, Inc.
The applicant is requesting approval for a new-single dwelling unit.
Curt Freese presented the staff report.
4
Public Comment:
Lise Sundrla, Historic Beaufort Foundation (HBF), talked about the context of this structure,
which is not the core commercial district, it’s a neighborhood commercial district and has always
been a neighborhood commercial district. She referred to the 1924 Sandborn Map. Some
elements are conflicting with the design and make it confusing whether it is residential or is
commercial. It needs to follow from staff’s perspective, be more reflective of the mixed-use
commercial on the street in its design.
Public comment closed.
Motion: Ms. Petrella made a motion to the table project. No one seconded the motion because
Mr. Sutton said its “non debatable”. The motion passed unanimously.
ADJOURNMENT
2:31:50
Mr. Berman made a motion seconded by Ms. Wilson to adjourn. The meeting ended at 4:31 pm.
1203 BAY STREET
Request for replacement of awning over
rear door entrance – The Cuthbert
House Inn (Contributing, c. 1790)
Docusign Envelope ID: 8F2FEAF5-9090-4263-A77D-0089BE42C932
HISTORIC REVIEW APPLICATION
MAJOR REVIEW (HISTORIC REVIEW BOARD)
Community Development Department
1911 Boundary Street, Beaufort, South Carolina, 29902
p. (843) 525-7011 / f. (843) 986-5606
Email: development@cityofbeaufort.org / Website: www.cityofbeaufort.org
OFFICE USE ONLY: Date Filed: 4:30-25
4/300
CR
Application Fee:
see attached schedule
Application #: 28711
Zoning District: T4HN
HAS PROJECT ATTENDED HTRC MEETING? (REQUIRED)☑ YES ☐NO
IS PROJECT A CONTRIBUTING STRUCTURE? ✓
O ORNON-CONTRIBUTING STRUCTURE:
FOR A LIST OF CONTRIBUTING OR NON-CONTRIBUTING STRUCTURES, PLEASE SEE:
https://cityofbeaufort.org/350/Beaufort-County-Historic-Sites-Survey
APPLICABILITY FOR HISTORIC REVIEW BOARD: Major discretionary review board (HDRB) approval shall apply
to applications for Certification of Appropriateness per Section 9.10.2 for the following requests (please check all that apply):
☐New building(s) in Historic District
☐Changes to exterior materials of Contributing Structures
☐Additions to Contributing Structures
Non-similar roof replacement on Contributing Structures (roof with different materials)
☐Window replacements on Contributing Structures
Major changes to a Contributing or Non-contributing Site
Demolition
☑Other changes to exterior of Contributing Structures
SUBMITTAL REQUIREMENTS: All forms and information shall be submitted digitally + 5 hard copies of all documents. In
addition to a complete application form, applicants shall submit the required items according to the checklists on the subsequent page.
Pursuant to Section 6-29-1145 of the South Carolina Code of Laws, is this tract or parcel restricted by any recorded covenant
that is contrary to, conflicts with, or prohibits the activity described in this application? ☐Yes ☑ No
APPLICANT, PROPERTY, AND PROJECT INFORMATION:
Chris Ramm
APPLICANT NAME:
APPLICANT ADDRESS: 1203 Bay Street, Beaufort SC 29902
APPLICANT E-MAIL.chris.Ramm@TaylorCompanies.us APPLICANT PHONE NUMBER: 336-414-0606
APPLICANT TITLE: ☑ Homeowner Tenant Architect Engineer Developer
CITY OF BEAUFORT
HTRC – Pre-Design Application Meeting
1911 BOUNDARY STREET
BEAUFORT, SOUTH CAROLINA 29902
(843) 525-7011 FAX: (843) 986-5606
Meeting Summary
Date: 4/9/2025
Project Address: 1203 Bay Street
Project Narrative: Proposal to replace existing green canvas awning at rear with new matte
black metal awning, including sign lettering
Applicant: Chris Ramm
Synopsis of staff comments:
• Planning and Zoning:
o Provide full dimensions of existing awning so we can have a direct numbers
comparison between the old and new.
o Lettering on the awning turns it into signage. Will need to fill out a sign
application form.
Code Section 6.6.1.B (Canopy/Awning Signs):
1. Maximum Number: 1 per building frontage or tenant space, per
street frontage.
2. Must allow 8 feet clearance above sidewalk.
3. Shall not be placed above 2nd floor window sill or cornice of
building, whichever is higher.
4. May encroach over sidewalk area no closer than 18 inches from
curb.
5. Only the valance area of the awning/canopy may be used as a
message area. The valance shall be a maximum of 1 ft tall with
lettering a maximum of 9 inches tall. The valance shall be made of
the same material and shall be the same color as the
awning/canopy.
• Building Codes:
o Must meet 140 mph wind load
• Architecture:
• 1203 Bay Street (Cuthbert House Inn)
o T4-HN
o Contributing
o Request to replace existing green fabric awning with new black metal awning
o NPS Preservation Brief Number 44: The Use of Awnings on Historic Buildings;
Repair, Replacement, and New Design.
Where no awning currently exists, and there is no evidence of a past one,
it may still be possible to add an awning to a historic building without
altering distinctive features, damaging historic fabric or changing the
building's historic character. A new awning should be compatible with the
features and characteristics of a historic building, as well as with
neighboring buildings, or the historic district, if applicable. Historic
photographs of similar neighboring buildings with awnings can also be
helpful in choosing an appropriate installation. When selecting and
installing a new awning, a number of other factors should be considered:
shape, scale, massing, placement, signage, and color.
Generally, traditional shed awnings are appropriate for most historic
window, door, and storefronts installations. It is preferable (and in some
historic districts, required) that these awnings have free-hanging
valances, the flapping bottom pieces so characteristic of historic awnings.
Quarter-round awnings, modern mansard awnings, and other
contemporary commercial designs with distended, fixed valances have no
precedent in traditional awning design and are usually inappropriate for
historic buildings.
Historically, awnings were covered with canvas that was either solid in
color or painted with stripes…Weather-resistant acrylic fabrics such as
solution-dyed acrylic and acrylic-coated polyester-cotton approximate the
historic look of canvas coverings, yet afford a new level of durability,
color-fastness, and ease of use. Quality poly-cotton coverings may be
more appropriate in some cases because, like traditional awnings, the
colors and stripes are painted directly on the upper surface, while the
underside remains a pearl gray color.
As in the past, variety in awning color is an appropriate characteristic
when reintroducing awnings in historic districts. Since the 19th century,
awnings have featured a range of different stripe patterns and an
extensive color palette. These lively, even whimsical, designs embellished
building facades like a necktie or scarf does a suit. The vibrancy they lent
to city streets and neighborhoods is part of the history of these
environments and similar results can be achieved today as well.
o Recommendations:
Staff don’t support the proposed metal awning for the reasons above
unless there is historical evidence that such an awning once existed.
The proposed shape of the metal awning is not complimentary to the style
of the structure.
Staff are worried about the scale of the proposed metal awning and its fit
and interaction above the door and below the soffit line.
Staff recommend that the replacement awning be made of canvas on a
metal frame.
It is recommended that the awning be a shed type with a triangular section.
This shape is most appropriate to tuck in under the existing architectural
soffit and molding detail above the door and below the second floor.
It is recommended that the applicant consider a retractable version of the
awning so that it can be stored on nice days and not obstruct the
architectural details of the building.
• HBF:
o In agreement with Architectural comments.
1. Historic look requires fitting with the timeframe of the building
2. Awning is almost oriental in style – not appropriate for the
structure/district.
o Canvas awning is more appropriate.
o Awning is supposed to frame, not go beyond the opening/door/window.
o For longevity, consider a flat metal shed awning without the crimps. Would be
more appropriate for the structure.
Applicant’s Next Steps: 2 options: Make changes, we’ll review, be on same page for the HRB.
Or, schedule a meeting with the HRB.
Be advised that this letter is given as a courtesy to applicants and may not contain all project guidelines.
For a complete history of the meeting, please request the audio recording. Please refer to the Beaufort
Code for applicable sections. If there are any changes to the project, not discussed in this meeting, you
will need to return to a HTRC – Pre-Design meeting.
If you have any questions, feel free to call the Community Development Department at (843) 525-7014.
Thank you for your patience and cooperation during the review process.
Sincerely,
City of Beaufort Community Development
CITY OF BEAUFORT
HTRC – Pre-Design Application Meeting
1911 BOUNDARY STREET
BEAUFORT, SOUTH CAROLINA 29902
(843) 525-7011 FAX: (843) 986-5606
Meeting Summary
Date: 4/23/2025
Project Address: 1203 Bay Street
Project Narrative: Follow-up meeting/discussion on suitable alternatives for canvas awning
replacement at the rear of the “Cuthbert House Inn”
Applicant: Chris Ramm (Homeowner)
Synopsis of staff comments:
• Planning and Zoning:
o Contributing Structure (c. 1790)
o T4-HN
o Will require HRB review/approval, NOT Staff level
• Architecture:
o While staff still support a canvas awning, staff is supportive of option 1 with the
following comments:
Roof should mimic the existing standing seam roof shown on the left with
its simple mechanical lock and low profile flashings.
The elimination of exposed rafter tails is a positive
Awning shall be sized to frame the existing door.
Applicant to provide a simple sketch with dimensions.
Staff level approval once all items submitted.
• HBF: In agreement with Architecture
Applicant’s Next Steps: Provide requested documents, we’ll schedule for an HRB meeting.
Be advised that this letter is given as a courtesy to applicants and may not contain all project guidelines.
For a complete history of the meeting, please request the audio recording. Please refer to the Beaufort
Code for applicable sections. If there are any changes to the project, not discussed in this meeting, you
will need to return to a HTRC – Pre-Design meeting.
If you have any questions, feel free to call the Community Development Department at (843) 525-7014.
Thank you for your patience and cooperation during the review process.
Sincerely,
City of Beaufort Community Development
STAFF REPORT: Historic District Review Board (HRB)
1203 BAY STREET
DATE: May 14, 2025
Background: The applicant is proposing to replace the current green canvas awning over the rear entrance door
(84” wide) with a standing seam metal shed roof-style awning/door shelter. The roof will mimic the existing
standing-seam metal roof that covers the lower-level east side. The roof will also have a low-profile flashing and
will be sized to complement the width of the existing door.
GENERAL INFORMATION
Applicant: Chris Ramm (Owner)
Site Address / Tax PIN: 1203 Bay Street; R120 004 000 771A 0000
Applicant's Request: Applicant is requesting approval for replacement of a green canvas
awning at the rear of The Cuthbert Inn with a standing seam metal shed
roof. The new metal roof with be 5’-0” wide, 3’-0” tall, and 3’-4” deep.
Current Zoning: T4-HISTORIC NEIGHBORHOOD DISTRICT (T4-HN)
Contributing/Neighborhood Contributing – The John A. Cuthbert House (c. 1790)
Flood Zone/Base Flood Flood Zone X, Elevation: 19’-22’
Existing Trees No Specimen/Landmark trees are affected by this request.
ZONING DISTRICT INFORMATION
T4-HISTORIC NEIGHBORHOOD DISTRICT (T4-HN)
Lot Width at Setback: 40 ft. min. / (60 ft. min in the Point)
Minimum Lot Size: 4,000 sq. ft. (6,000 sq. ft. in The Point)
Max Lot Coverage: 55% of lot area (This percentage indicates maximum lot coverage by roofs;
total impervious coverage may be an additional 10%. Parcels may also be
subject to Section 8.3 - Stormwater)
Min. Frontage Build Out 75% max.
Front Setback Average Prevailing Setback on Block
Side Setback Corner: 5 ft min.; Interior: 6 ft min. (10 ft min. in The Point)
Rear Setback 15 ft min; from alley: 0 ft.
Building Height: 3 stories max. (primary); 2 stories / 30 ft. max. (accessory)
SURROUNDING ZONING, LAND USE AND REQUIRED BUFFERS
Adjacent Zoning Adjacent Land Uses Setbacks for Adjacent Zoning
/Buffer required if rezoned
North: T4-HN First Presbyterian Church (410
Church St.) N/A
South: T1 Beaufort Harbor N/A
East: T4-HN Historic, contributing structure
(1113 Craven St., c. 1815) N/A
West: T4-HN Historic, contributing structure
(1207 Bay St., c. 1800) N/A
2
Applicant has been to two (2) HTRC Meetings on April 9th and April 23rd 2025 and has presented two (2)
options for the canvas awning replacement: (1) a one-piece, manufactured metal awning structure, and (2) a
wood-framed awning with a standing-seam metal roof that matches the look at the neighbor’s property.
The applicant has been provided with the following comments in light of the presented alternatives:
Regarding Architectural Design and Preservation Standards (by Meadors Architects, Charleston):
1. General reference to NPS Preservation Brief No. 44 (The Use of Awnings on Historic Buildings):
o Where no awning currently exists, and there is no evidence of a past one, it may still be possible to add an
awning to a historic building without altering distinctive features, damaging historic fabric or changing
the building's historic character. A new awning should be compatible with the features and characteristics
of a historic building, as well as with neighboring buildings, or the historic district, if applicable. Historic
photographs of similar neighboring buildings with awnings can also be helpful in choosing an appropriate
installation. When selecting and installing a new awning, a number of other factors should be considered:
shape, scale, massing, placement, signage, and color.
o Generally, traditional shed awnings are appropriate for most historic window, door, and storefronts
installations. It is preferable (and in some historic districts, required) that these awnings have free-
hanging valances, the �lapping bottom pieces so characteristic of historic awnings. Quarter-round
awnings, modern mansard awnings, and other contemporary commercial designs with distended, �ixed
valances have no precedent in traditional awning design and are usually inappropriate for historic
buildings.
o Historically, awnings were covered with canvas that was either solid in color or painted with
stripes…Weather-resistant acrylic fabrics such as solution-dyed acrylic and acrylic-coated polyester-
cotton approximate the historic look of canvas coverings, yet afford a new level of durability, color-
fastness, and ease of use. Quality poly-cotton coverings may be more appropriate in some cases because,
like traditional awnings, the colors and stripes are painted directly on the upper surface, while the
underside remains a pearl gray color.
o As in the past, variety in awning color is an appropriate characteristic when reintroducing awnings in
historic districts. Since the 19th century, awnings have featured a range of different stripe patterns and an
extensive color palette. These lively, even whimsical, designs embellished building facades like a necktie or
scarf does a suit. The vibrancy they lent to city streets and neighborhoods is part of the history of these
environments and similar results can be achieved today as well.
2. Staff does not support the metal awning (alternative #1), as it is not complimentary to the architectural style of
The Cuthbert House (federal era). Also, architecture staff was not in support of the presented dimensions of the
metal awning, as it appeared overbearing in regard to the width and height of the rear entrance door.
3. Architecture staff recommended either replacement with a new canvas-awning or the use of a shed-type
awning with a triangular section (alternative #2), as this shape would be more appropriate in conjunction with
the existing architectural features, i.e. sof�it and molding above the door. However, the initially presented shed-
type roof included rafter tails that were not supported by staff.
Historic Beaufort Foundation (HBF) remarks:
A. Generally in agreement with architecture staff comments (Meadors – see above).
B. Moreover, HBF was initially more in support of a canvas-style awning replacement. However, HBF staff also
3
mentioned that a shed-style roof would provide more longevity than a canvas awning, but without the crimps.
Illustration of presented alternatives (#1 & #2) – however, as a outcome of the previous HTRC discussions,
applicant will proceed with approval request only for alternative #2 – option 1 (shed-roof style structure)
Present structure: Alternative #1 – Metal awning (will not be further pursued):
Alternative #2 – Shed-roof awning:
Option 1 - will be pursued for HRB approval Option 2 (will not be further pursued)
4
Summary regarding HTRC comments:
Item Applicant response(s) / meeting summaries
New awning must be able to withstand winds of
140+ mph
Applicant has acknowledged this requirement.
Replacement with new canvas awning – staff
supported
Not an option for the applicant (for longevity
reasons)
Replacement with metal awning - not supported
by staff & HBF
Applicant has agreed to dismiss this alternative
Replacement with shed-roof like awning (custom
built) – staff-recommends this alternative
without the rafter tails
a) Applicant is favorable to this alternative, as it
also matches similar shed-roof on neighbor’s
property (1207 Bay St.)
b) Applicant has submitted new option without
rafter tails (Option #1 to be further pursued for
approval)
New shed-roof awning to complement door
frame width (60”) and respect soffit & molding
above rear door & to resemble primary
architectural details of The Cuthbert House
The proposed shed-roof awning (60” x 40” x 36”)
will have a standing seam metal roof that mimics
the existing roof on the lower-level (east side) &
entrance of 1207 Bay St. (neighbor to west); also,
the roof will have a simple mechanical lock and low-
profile flashing. The awning will be sized to frame
the existing door.
Tree Removal Proposed:
No Specimen/Landmark trees are affected.
Surrounding Area:
This property, referred to as The John A. Cuthbert House (c. 1790), is considered one the most prominent and
recognized assets to the Beaufort Historic Landmark District. The immediate neighborhood along Bay Street,
which faces Beaufort Harbor and is one of the two major thoroughfares in historic Beaufort, is home to many
grandiose and well preserved historic homes, such as The Secession House (c. 1815; 1113 Craven St.), The Robert
Means House (c. 1800; 1207 Bay St.) and The Thomas Fuller House (c. 1786; 1211 Bay St.).
5
Determination of adequate historic integrity for New Construction, Infill, Additions and Demolition:
As per the Beaufort Preservation Manual (Chapter 5) and the Beaufort Development Code (Section 4.7), the
compatibility of new infill construction as well as major renovations within Beaufort Historic District is determined
in consideration with the following principles: 1. Location, 2. Design, 3. Setting, 4. Materials, 5. Workmanship,
6. Feeling and 7. Association. See detailed staff analysis and recommendations in table below.
4.7.2 Integrity Guidelines (as per Beaufort
Development Code)
Rationale
Present
Staff Analysis of Rationale
1. Location: This is the relationship between the
property and its historical context.
YES The Cuthbert House sits on Bay St. and thus
is highly visible from three sides (front
façade on Bay Street, east façade on Church
Street, and rear façade, also on Church
Street). The proposed design of the new
shed-roof awning complements the
architectural design of the house and
respects the historic context of the
surrounding area.
2. Design: This is the combination of elements
that create the feeling of a district or structure.
These elements include building patterns,
streetscapes, site elements, building size, mass
and scale, spatial relationships, and specific
architectural elements and details.
YES The proposed dimensions of the shed-roof
over the rear entrance door complement the
width of the door (5’-0”) and neither
obscure the molding and soffits of the
second floor above nor go against the
overall architectural design of the house and
its period.
3. Setting: This is the physical environment of a
property and should be evaluated on its context
as well as on the historical role the property has
played and continues to play. Important features
include topography, vegetation, man-made
features, and relationships between existing
structures and their surroundings.
YES The relationship between the existing
(architecture) of the house and the historic
setting of the neighborhood are well
respected by the proposed design, materials
and dimensions.
4. Materials: These are the physical elements
that make up a property or district.
YES See Above
5. Workmanship: This is the physical evidence
of the crafts of a particular culture or time
period. This particularly applies to rehabilitation
projects, but for new infill projects, workmanship
YES The proposed shed-roof awning will be
custom built, and all chosen materials will
be of high quality.
6
of surrounding structures should be considered
and respected.
6. Feeling: This is the property's expression of
the aesthetic or historic sense of a particular
period of time. This particularly applies to
rehabilitation projects, but for new infill projects,
the feeling of surrounding structures should be
considered and respected.
YES The proposed aesthetics respect and
promote the feeling in regard to historic
sense, composition and architecture.
7. Association: This is the direct link between an
important historic event or person and a
property.
YES The proposed shed-roof awning is in
keeping of the architectural integrity and
preservation standards and thus respects
the historic importance the Cuthbert House
has to the Beaufort Historic District.
FINDINGS AND RECOMMENDATIONS
Staff Recommendation: Staff recommends Final Approval for the proposed awning structure (Alternative
#2, Option 1), in that it satisfies the intent of the Beaufort Preservation Manual and requirements of the
Beaufort Code, for the following reasons:
1) The applicant has constructively followed staff recommendations in changing the initial design from a
metal awning construct to a more suitable shed roof that mimics the existing standing seam metal
roof on the left of the house, and which includes a simple mechanical lock, low-profile flashings, and
no exposed rafter tails.
2) The proposed shed-roof awning is well suited in respect to the dimension of the rear door width as
well as to the surrounding details (soffits, moldings) and overall architectural style of the house.
3) The shed-roof awning also complements very similar ones in the neighborhood, particularly at 1207
Bay Street.
Additionally, staff recommends provision of the following items in conjunction with Final Approval:
A. Applicant to provide architectural drawings including a roof plan, section, and details showing the
wall flashing, fascia, and brackets.
B. Applicant to submit a cutsheet for the metal roof, as well as the roof brackets if they are to be
premanufactured. The roof cutsheet should indicate the proposed color and seam profile.
C. Applicant to confirm if paint colors are to match that of the existing house.
1107 Prince Street
Partial Demolition &
Renovation/Addition of a ca. 1960
Noncontributing House
W
ilm
ington St
King St King St
Elton Ln
Monson St
Monson St
North St North St
Church St
Church St
Prince St
Duke St
Prince St
Washington St
Harrington St
Newcastle St
Harrington St
Newcastle St
Newcastle St
Harrington St
North St
Church St
Harrington St
King St
Newcastle St
Newcastle St
Newcastle St
Harrington St
King St
North St
Church St
King St
North St
Scott St
W
est St
King St
North St
Scott St
Charles St
King St
North StNorth St
W
est St
King St
Scott St
W
est St
Charles St
Charles St
Washington St
Duke St
W
est St
Scott St
Duke St
Washington St
Scott St
W
est St
Charles St
Prince St
Prince St
Crofut Ln
Duke St
Monson St
Prince St
Washington St
W
ilm
ington St
Monson St
Duke St
Bladen Ln
Monson St
W
ilm
ington St
W
ilm
ington St
Duke St
Monson St
Zoning Map
Road Classifications
STATE, PAVED
MUNICIPAL, PAVED
MUNICIPAL, UNPAVED
LiveParcels
HISTORIC DISTRICT-Preservation Heighborhood
HISTORIC DISTRICT-Conservation Neighborhood
Bladen Street Redevelopment District
Boundary Street Redevelopment District
Retail Overlay (Church & Green Street)
Retail Overlay
Zoning Districts
LEGACY PUD (LPUD)
T1
T3-S
T3-N
T4-HN
T4-N
T4-NA
T5-DC
T5-UC
T5-UC / RMX
RMX
IC
MH
LI
MR
5/7/2025, 9:59:06 AM
0 0.055 0.110.0275 mi
0 0.085 0.170.0425 km
1:2,257
Data supplied for you by Beaufort County Mapping and Applications, powered by Web AppBuilder for ArcGIS
Your Name Here
17
17
17
16
16
22
22
21
21
21
21
21
21
21
21
21
20
20
20
20
20
20
202020 20
20
20
2020 20
20
20
20
20
20
20
20
19
19
19
19
19
19 19 19
191919 19
1919
19
1919
19
19
19
19
19
18
18
18
18
18
18
18
18
18
18
18
18 1818
18
18
17
17
17
17
17
17
1717
17
16
20
20
20
19
19
19 19
19 18
18
18
18
18
18
18
18
18
18
18
18
18 18
18
18
17 1717
17
1717
17
17 17
17
17
17
17
17 17
17
17
17
17
1717
17
17
17
17
17
17
17
17
17
1717
17
17
16
1616
16
16
16
16
15
25
25
25
24
24
24
24
23
23
23 2323
23
23 23
23
23
23
23
23
2323 23
23232323
23
23
23
2323
23
23
23
2323
22
22
22 22
22
22
2222
22
22
22
22
22
22
22
2222 22
22
22
22
22
22
22
22
21
21 21
21
2121
21
21
21
21
21
2121
21
21
21
21
21
20
20
20
20
20
20
20
20
2020
20
2020
20 19
19 19
23
23
23
23
23
23
23
23
22
22
21
21
1817 17 171311
19 19
19
18
1818
18 18 18
18
18
18
18
18
18
17 17
1717
17
17
17
17 17
17
17
17
17
17
17
16
16
16
16
16
16 16
16
16
16
16 16
15
15
15
15
15
14
14
14
14
14
13
13
13
13
12
12
12
12
12
12
12
12
17
17
16
16
16
16
16
17161616
19
18
18
18
18 18
17
17
17 17
171717 17
17 17
17
1717
1717
17
17 17
17
17 1717 17 17 17
17 17
17 17
1717
17
17
17
17
17 17 17
17
17
17
17
17
17
17
1717
17
17
17
17
17
17
16
16
16
16
16 16
161616
16 16
16
16
1616
16
16
16
161515
15
21 19
22
22
2222 22
22 22
2222
21
21
212121 21
21
21
21
21 21
21
21
21
21
21
21
21
21
21
20
20
20
20
20
20
19
19
19
19
19
19
19
19
18
18
18 17
17
16
16
16
16
14 14
14
13
13
23
22
22 22
22
22
22
21
21
21
21
Prince St
Prince St
Prince St
Prince St
Duke St
Church St
Charles St
Charles St
Duke St Duke St
Duke St
Harrington St
Harrington St
Elevations Map
All Contours 2020
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
Road Classifications
STATE, PAVED
LiveParcels
Flood Zones
X
5/7/2025, 10:03:24 AM
0 0.025 0.050.0125 mi
0 0.04 0.080.02 km
1:1,128
Data supplied for you by Beaufort County Mapping and Applications, powered by Web AppBuilder for ArcGIS
Your Name Here
MAIN HOUSE
EXISTING FIRST FLOOR.......................1,224 S.F.
NEW FIRST FLOOR............................... 259 S.F.
TOTAL CONDITIONED...........................1,483 S.F.
NEW SCREENED PORCH.....................310 S.F.
NEW FRONT PORCH.............................254 S.F.
NEW BACK TERRACE...........................263 S.F.
SITE INFORMATION
TOTAL PERVIOUS AREA.......................8,008 S.F.
TOTAL IMPERVIOUS AREA...................2,047 S.F.
2024 All Rights ReservedC
1
A4.3
1
A4.1
1
A5.1
1
15.75'
A
1
1
GYPSUM WALLBOARD
(LARGE SCALE)
ACOUSTIC TILE
CARPET & PAD
GYPSUM WALL BOARD
(ELEVATION)
FLASHING, ETC
BRICK (ELEVATION)
HORIZONTAL SIDING
(ELEVATION)
ROOF SHINGLES
(ELEVATION)
WATERPROOFING, FELT,
CONTINUOUS
BLOCKING
ROUGH LUMBER
ROUGH LUMBEREARTH
GRAVEL
FINISH WOOD
INSULATION BATTS
RIGID INSULATION
PLYWOOD (LARGE SCALE)
PLYWOOD (SMALL SCALE)
CONCRETE
C.M.U.
BRICK
STEEL
DETAIL-NO.
SHEET-NO.
ENLARGED
DETAIL INDICATOR
SHEET-NO.
DETAIL-NO.
SECTION CUT INDICATOR
INTERIOR ELEVATION INDICATOR
WINDOW MARK
DOOR MARK
ELEVATION ABOVE MEAN SEA LEVEL
DETAIL-NO.
SHEET-NO.
OR OTHER SPECIFIED DATUM
WALL TYPE
REVISION NUMBER
Refrigerator
Roof Drain
Radius
Riser
Room
Roof Joist
Required
Revision
Reinforcing
Rough Opening
Sheet
Shelf
Schedule
Square Foot
Square
Specification
Similar
Solid Masonry Pier
Stainless Steel
Solid Core Wood
Telephone
Tread
Suspended
Steel
Top of Steel
Through
Threshold
Thick
Top of Plate
Typical
Top of Slab
Without
Wood
With
Vertical
Unless Otherwise Noted
Verify in Field
Vinyl Composition Tile
Top of Sheathing
Standard
Quanity
R.
Floor
Foot
FL.
F.D.
GA.
FT.
F.J.
Hose Bib
GYP.BD.
GALV.
H.M.
HCWD.
H.B.
Gauge
Hollow Metal
Gypsum Board
Galvanized
Floor Joist
Floor Drain
Hollow Core Wood
Height
Lavatory
Laminate
Kitchen
HGT.
HORIZ.
LAV.
LAM.
KIT.
Masonry
Light
Maximum
LT.
MAS.
MEMB.
MECH.
MAX.
Membrane
Mechanical
Horizontal
A.F.F.
ADJ.
ABV.
BD.
APPROX.
ANG.
ALT.
ALUM.
Board
Approximate
Angle
Alternate
Aluminum
Above Finish Floor
Adjacent
Above
BOT.
BSMT.
BM.
BLKG.
L
CLO.
CLG.
C.T.
C
CAB.
Closet
Ceiling
Ceramic Tile
Center Line
Cabinet
Bottom
Basement
Beam
Blocking
BuildingBLDG.
T.Minimum
MFR.
MET.
M.O.
MISC.
MIN.
N.I.C.
O.D.
O.C.
N.T.S.
Outside Diameter
On Center
Not To Scale
Not In Contract
Masonry Opening
Miscellaneous
Manufacturer
Optional
Plate
Precast
OPT.
OPNG.
PL.
P.LAM.
P.C.
Pair
Plywood
PR.
PLYWD.
P.S.I.
P.S.F.
P.T.
Pounds Per Square Inch
Pounds Per Square Foot
Pressure Treated
Plastic Laminate
Opening
CONC.
COL.
CMU.
C.O.
DIA.
D.F.
DTL.
DEPT.
CONT.
Dimension
Diameter
Drinking Fountain
Detail
Department
Continuous
Concrete
Column
Concrete Masonry Unit
Cased Opening
EA.
DWG.
DS.
DN.
EQUIP.
EQ.
EMER.
ELEC.
EL.
E.J.
Equipment
Equal
Emergency
Electrical
Elevation
Expansion Joint
Each
Drawing
Down Spout
Down
DIM.
Metal
CentimeterCM.
ExteriorEXT.
UON.
S.M.P.
REF.
W/O
WD.
W/
V.I.F.
VERT.
VCT.
TYP.
T.O.SL.
T.O.SH.
T.O.S.
T.O.P.
THRU.
THRES.
THK.
TEL.
SUSP.
STL.
STD.
S.S.
SQ.
SPEC.
SIM.
SHT.
SH.
SCWD.
SCHED.
R.O.
RM.
R.J.
REQD.
REV.
REINF.
R.D.
RAD.
QTY.
S.F.
Weight
Welded Wire Fabric
P.V.C. Polyvinyl Chloride
E.W.
EXIST.
Each Way
Existing
WWF
WT.
WaterproofingPainted WP.PTD.
SYMBOLS INDEX OF DRAWINGSSPECIFICATIONSABBREVIATIONS
MATERIALS
EXTERIOR ELEVATION INDICATOR
A5.1
1
SHEET-NO.
DETAIL-NO.
LOCATOR MAP BUILDING INFORMATION
3
24
Finished Room Over GarageFROG
NOT FOR
CONSTRUCTION
5/1/2025 11:45:28 AM
.0.0
TITLE SHEET
HRB
REVIEW
1107 Prince St. Beaufort, SC
05/01/2025
1107 PRINCE RENOVATION
1107 Prince St. Beaufort, SC
SCOPE NARRATIVE:
1. DEMOLISH, LEAVE FOUNDATION
2. ENCLOSE EXISTING SCREENED PORCH
3. EXTEND THE MAIN HOUSE FOOTPRINT AT THE FRONT
4. NEW SCREENED PORCH
5. NEW TERRACE
FUTURE SCOPE:
1. EXTEND THE MAIN HOUSE FOOTPRINT AT THE BACK
2. NEW CARRIAGE HOUSE
3. NEW COURTYARD AND COVERED WALKWAY
Sheet
Number Sheet Name
.0.0 TITLE SHEET
A1.0 SITE PLAN AN D EXISTING SURVEY
A2.1 FLOOR & FOUNDATION PLAN
A2.2 REFLECTED CEILING & ROOF PLAN
A3.1 EXTERIOR ELEVATIONS, WINDOW & DOOR SCHEDULES
A3.2 3D VIEWS
A4.1 BUILDING AND WALL SECTIONS
A4.2 DETAILS
E.1 FIRST FLOOR ELECTRICAL
A3.1
A3.1
A3.13
A3.1
1
2
4
20' - 0"
EXIST
ING HOUSE
AD
DITION
FUTURE
ADDITION
ENCLOSE
EX
IST
ING
PORCH
NEW
PO
RCH
NEW
TERRACE
NEW
SCREENED
PORCH
FUTURE
COURTYAR
D
FUTURE GARAGE
NEW DRIVEWAY
NEW DRIVEWAY
GATE
WALKWAY
ACCESSORY SETBACK
MAIN SETBACK
TREE PROTECTION
TREE PROTECTION
REMOVE TREE
PLANTATION MIX
ROCK BOX
ROCK BOX
RAIN
GARDEN
RAIN
GARDEN
PLANTATION
MIX
WALKWAY
/6 A1.0
/6 A1.0
DOWNSPOUT
/4 A1.0
/4 A1.0
HANDRAIL
HANDRAIL
SERVICE
YARD
15' - 0"
5' - 0"
5' - 0"
5' - 0"
10' - 0"
11' - 0"
FINISH GRADE
4" HEAVY DUTY STEEL EDGE
WITH 16" STAKES @ 32" O.C.
1-1/2" PLANTATION MIX
3" CHRUSH AND RUN BASE
GEOTEXTILE MEMBRANE
COMPACTED FILL
PLAN
SECTION
1' - 0"
1' - 0"
4x6 CYPRESS,
MITER CORNERS
2" BLACK RIVER
ROCKS
2" BLACK RIVER
ROCKS
RAIN CHAIN
GRADE
CATCH BASIN &
PIPE AS REQ'D
2' DEEP WELL-
DRAINING SOIL
CATCH BASIN &
PIPE AS REQ'D
3"-6" PONDING AREA
2"-3" ORGANIC MULCH LAYER
SHREDDED BARK
2' - 6" PLANT MEDIUM
50% COARSE SAND
25% COMPOST
25% TOPSOIL
GEOTEXTILE FABRIC
BERM (WHERE REQUIRED)
SEE LANDSCAPE PLAN
FOR RAIN GARDEN GRASSES,
SHRUBS AND TREES( WAX
MYRTLE, VIBURNUM, YAUPON
HOLLY, SWITCH & MUHLY
GRASS) .
2x4 TO RUN ALONG STRINGERS
STRINGER
1x SKIRT AND RISER
(PAINTED)
MITER PERIMETER
LANDING AS SPECIFIED
FOR 14" TREADS: 5/4x6 W/ 5/4X6 PERIMETER, SPACE BOARDS 1/4"
SEE STRUCTURAL
DWGS FOR FOOTING
SIZE & DETAILS
2x4 TO SPAN BTWN
STRINGERS - NOTCH
INTO STRINGERS
FOR 11" TREADS: 5/4x6 - RIPPED W/ 5/4X4 PERIMETER,
SPACE BOARDS 1/8"
3' - 5 1/2"10'-0" MAX.
2' - 0"3' - 6"
P.T. PINE OR WESTERN
RED CEDAR SPLIT RAIL
FENCE
EQEQ
2024 All Rights ReservedC
NOT FOR
CONSTRUCTION
5/1/2025 11:45:28 AM
A1.0SITE PLAN AND EXISTING SURVEY
HRB
REVIEW
1107 Prince St. Beaufort, SC
05/01/2025
1/8" = 1'-0"1 SITE PLAN
NOTE:
ALL SURVEY RELATED INFORMATION INDICATED IN THESE
DOCUMENTS, INCLUDING BUT NOT LIMITED TO ELEVATION
CONTOURS, TREE SIZE, SPECIES AND LOCATION, WERE
PROVIDED BY A THIRD PARTY LICENSED SURVEYOR.
ELEVATION CONTOURS ARE BASED ON NAVD88 DATUM. IT IS
THE BUILDERS RESPONSIBILITY TO CONSULT WITH A LICENSED
SURVEYOR FOR INSTALLATION OF A TEMPORARY ELEVATION
BENCHMARK FOR USE IN DETERMINING THE REQUIRED FLOOR
ELEVATIONS INDICATED IN THESE DOCUMENTS. NOTIFY
ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES BETWEEN
EXISTING SITE CONDITIONS AND THE INFORMATION PROVIDED
IN THESE DOCUMENTS.
N
1" = 1'-0"5 PLANTATION MIX SURFACE & BORDER
3/4" = 1'-0"6 RAIN CHAIN
1" = 1'-0"4 RAIN GARDEN DETAIL
1/2" = 1'-0"2 EXTERIOR WOOD STAIR
1" = 1'-0"3 TREE PROTECTION FENCE DETAIL
A3.1
A3.1
A3.1
3
A3.1
1
2
4
H.W.H.
BEDROOM
1
GREAT
ROOM
BEDROOM
2
BATH 1BATH 2
LAUNDRY/PANTRY
P.R.
OFFICE
SCREENED
PORCH
FRONT
PORCH
TERRACE
CLOSET
CLOSET
10' - 0"
10' - 0"
10' - 6"
16' - 1"
12' - 6 1/4"
13' - 4"
10' - 0"
14' - 4 3/4"
10' - 7 7/8"
DH2 DH1 DH1 DH2 DH2
DH1
DH1
DH1
01
DH1
DH1
11
08
0405
09
0607
10
1516
20
21
03 02
1
A4.1
2
A4.1
DH1
FURR UP
FLOOR TO
ALIGN WITH
EXISTING
INTERIOR
FLOOR
TIMBERTECH DECKING, TYP
TIMBERTECH
DECKING, TYP
ACOUSTICAL BATT INSULATION, TYP. ON INTERIOR WALLS
14' - 1"
24' - 6"
5' - 0 1/2"
4' - 9 1/2"
6' - 0"
8' - 4 5/8"
4' - 6 1/2" 2' - 1"
5' - 4"
8' - 7 1/2" 8' - 4 3/4" 8' - 4 3/4"
13
DH3
DH3
DH1
DH1
= EXISTING FOOTPRINT
OF CONDITIONED SPACE
1/4" / 12"
8' - 6" 9' - 3 1/2" 8' - 6"
1
A4.1
2
A4.1
FEILD VERIFY EXISTING
FOUNDATION CONDITION.
EXISTING PIERS ARE NOT SHOWN
ACCESS
GRIFFOLIN 20 MIL
REINFORCED VAPOR BARRIER
STRUCTURAL NOTES FOR PRELIMINARY
PRICING PURPOSES ONLY. FINAL
STRUCUTRAL ENGINEERING WILL BE
PROVIDED IN THE PERMIT SET.
GRIFFOLIN 20 MIL
REINFORCED VAPOR BARRIER
SEAL EXISTING CRAWL SPLACE
SEALED
CRAWL
SPLACE
LATTICE
16x16 PIERS
36x36 PIER FOOTINGS
BRICK ON 8" CMU WALL
36" CONTINUOUS FOOTING
4' - 0" 24' - 6"
8' - 0 3/4" 7' - 0" 5' - 11 1/4" 4' - 0"
10' - 6" 10' - 0"
10' - 0" 8' - 7 1/2" 8' - 4 3/4" 8' - 4 3/4" 14' - 1"
10' - 0"
49' - 6"
46' - 9 1/2"
ACCESS
FLUSH BRICK W/ EXISTING
EXISTING RAISED SLAB ON GRADE
= EXISTING
= NEW
CUT PATTERN
= EXISTING
= NEW
SURFACE PATTERN
PHASE LEGEND
2024 All Rights ReservedC
NOT FOR
CONSTRUCTION
5/1/2025 11:45:29 AM
A2.1FLOOR & FOUNDATION PLAN
HRB
REVIEW
1107 Prince St. Beaufort, SC
05/01/2025
1/4" = 1'-0"1 FIRST FLOOR
PRELIMINARY HVAC NOTES:
• MAIN HOUSE AIR HANDLER LOCATED IN ATTIC.
• MAIN HOUSE (1) 2.5 TON AHU
• (1) MAIN HOUSE DEHUMIDIFIER
• (1) MAIN HOUSE ERV
1/4" = 1'-0"2 FOUNDATION
Room Finish Schedule
Room Name
Finish Finish Countert
op Cabinets Shower/Tub surround CommentsFloor Base Wall Ceiling
BATH 1 TILE WOOD DRYWALL DRYWALL QUARTZ PAINTED TILE
BATH 2 TILE WOOD DRYWALL DRYWALL QUARTZ PAINTED TILE
BATH 3 TILE WOOD DRYWALL DRYWALL QUARTZ PAINTED TILE
BEDROOM 1 WOOD WOOD DRYWALL DRYWALL
BEDROOM 2 WOOD WOOD DRYWALL DRYWALL
BEDROOM 3 WOOD WOOD DRYWALL DRYWALL
COURTYARD PLANTATION MIX
FRONT PORCH TIMBERTECH T&G WOOD
GARAGE CLEAR EPOXY WOOD DRYWALL DENSGLASS
GREAT ROOM WOOD WOOD DRYWALL DRYWALL QUARTZ PAINTED
GUEST 3 LIVING WOOD WOOD DRYWALL DRYWALL QUARTZ PAINTED
LAUNDRY/PANTRY TILE WOOD DRYWALL DRYWALL PAINTED
OFFICE WOOD WOOD DRYWALL DRYWALL PAINTED
P.R. WOOD WOOD DRYWALL DRYWALL QUARTZ PAINTED
SCREENED PORCH TIMBERTECH T&G WOOD
TERRACE TIMBERTECH
1
A4.1
2
A4.1
BEDROOM
1
BATH 1
BATH 2
BEDROOM
2
GREAT
ROOM
OFFICE
P.R.
LAUNDRY/PANTRY
SCREENED
PORCH
9' - 11 1/2"
9' - 11 1/2"
9' - 11 1/2"
9' - 11 1/2"
8' - 4 3/4"
8' - 4 3/4"
9' - 11 1/2"
9' - 11 1/2"
9' - 11 1/2"
9' - 11 1/2"
9' - 11 1/2"
7" / 12" 7" / 12"
7" / 12" 7" / 12"
3" / 12"COLLAR TIES @
8'-0" O.C.
COLLAR TIES @
8'-0" O.C.
T&G CEILING
PAINTED
T&G CEILING
PAINTED
DRYWALL, TYP.
A3.1
A3.1
A3.1
3
1
2
7" / 12"7" / 12"
7" / 12" 7" / 12"
7" / 12" 7" / 12"
3" / 12"
VERIFY EXISTING
SLOPE & MATCH
1
A4.1
2
A4.1
HALF ROUND GUTTER
RAINCHAIN
RAINCHAIN
HALF ROUND GUTTER
DOWNSPOUT
ALL NEW METAL ROOF
DOWNSPOUT
2024 All Rights ReservedC
NOT FOR
CONSTRUCTION
5/1/2025 11:45:30 AM
A2.2REFLECTED CEILING & ROOF PLAN
HRB
REVIEW
1107 Prince St. Beaufort, SC
05/01/2025
1/4" = 1'-0"1 FIRST FLOOR
1/4" = 1'-0"2 ROOF PLAN
FIRST FLOOR
0"
GRADE
-2' - 0"
NEW ROOF
PLATE
10' - 0"
EXISTING ROOF
PLATE
8' - 0"
NEW TYP. WIN. & DOOR
8' - 0"
DH1DH101DH1DH1
1
A4.1
2
A4.1
DH1
HARDIE REVERSE BOARD &
BATTEN SIDING
METAL STANDING SEAM
FIRST FLOOR
0"
GRADE
-2' - 0"
NEW ROOF
PLATE
10' - 0"
EXISTING ROOF
PLATE
8' - 0"
2021
1
A4.1
2
A4.1
DH3 DH3 DH1 DH1
FIRST FLOOR
0"
GRADE
-2' - 0"
NEW ROOF
PLATE
10' - 0"
EXISTING ROOF
PLATE
8' - 0"
11
DH1
02 03
T1
T2
WINDOWS BEYOND
INSECT SCREEN ON 3x4 WOOD FRAME
FIRST FLOOR
0"
GRADE
-2' - 0"
NEW ROOF
PLATE
10' - 0"
EXISTING ROOF
PLATE
8' - 0"
DH2DH2
DH1DH1
DH2
2024 All Rights ReservedC
NOT FOR
CONSTRUCTION
5/1/2025 11:45:31 AM
A3.1EXTERIOR ELEVATIONS, WINDOW & DOOR SCHEDULES
HRB
REVIEW
1107 Prince St. Beaufort, SC
05/01/2025
1/4" = 1'-0"1 SOUTH ELEVATION
1/4" = 1'-0"2 NORTH ELEVATION
1/4" = 1'-0"3 EAST ELEVATION
1/4" = 1'-0"4 WEST ELEVATION
Window Schedule
Type Mark
Frame Size
Manufacturer Model Comments CountWidth Height
DH1 2' - 9 5/8" 5' - 8 7/8" Andersen Cor poration 400-Series T ilt-Wash Double Hung 10
DH2 2' - 7 5/8" 3' - 4 7/8" Andersen Cor poration 400-Series T ilt-Wash Double Hung 3
DH3 2' - 11 5/8" 5' - 0 7/8" Andersen Cor poration 400-Series T ilt-Wash Double Hung 2
T1 Andersen Corporation FLEXIFRAME SEE BUILDING SECTION FOR DIMENSIONS 1
T2 Andersen Corporation FLEXIFRAME SEE BUILDING SECTION FOR DIMENSIONS 1
Door Schedule
Door
Number
Unit Size
Elevation Manufacturer Model
Finish
Width Height Comments
01 3' - 4" 8' - 0" CUSTOM
02 5' - 11 1/4" 7' - 11 1/2" Anders en Corporation A-Series Gliding
03 5' - 11 1/4" 7' - 11 1/2" Anders en Corporation A-Series Gliding
04 3' - 0" 8' - 0"
05 3' - 0" 8' - 0"
06 2' - 6" 8' - 0"
07 3' - 0" 8' - 0"
08 4' - 0" 8' - 0"
09 4' - 0" 8' - 0"
10 3' - 0" 8' - 0"
11 3' - 0 1/8" 7' - 11 1/2" Andersen Corporation A-Series
13 2' - 6" 6' - 8"
15 2' - 6" 8' - 0"
16 2' - 6" 8' - 0"
20 3' - 3 3/4" 8' - 9"
21 3' - 3 5/8" 8' - 9"
ALL WINDOWS TO BE IMPACT RATED
ANDERSON 400 SERIES
FUTURE CARRIAGE HOUSE
FUTURE ADDITION
FUTURE CARRIAGE HOUSE
FUTURE ADDITION
= EXISTING
= NEW
CUT PATTERN
= EXISTING
= NEW
SURFACE PATTERN
PHASE LEGEND
2024 All Rights ReservedC
NOT FOR
CONSTRUCTION
5/1/2025 11:45:32 AM
A3.23D VIEWS
HRB
REVIEW
1107 Prince St. Beaufort, SC
05/01/2025
1 3D SOUTH EAST
2 3D NORTH WEST
FIRST FLOOR
0"
GRADE
-2' - 0"
NEW ROOF
PLATE
10' - 0"
EXISTING ROOF
PLATE
8' - 0"
BEDROOM
1BATH 1BATH 2BEDROOM
2OFFICE
FIRST FLOOR
0"
GRADE
-2' - 0"
NEW ROOF
PLATE
10' - 0"
EXISTING ROOF
PLATE
8' - 0"
GREAT
ROOM
A4.1
3
T2
T1
6' - 6 5/8"
5' - 11 1/4" 5' - 11 1/4"
3' - 7 3/4"
1' - 7 1/2"
7"
12"COLLAR TIES
FIRST FLOOR
0"
NEW ROOF
PLATE
10' - 0"
EXISTING ROOF
PLATE
8' - 0"
GRIFFOLIN 20 MIL REINFORCED
VAPOR BARRIER
CLOSED CELL FOAM
INSULATION R-19
EXISTING FOUNDATION
8x8 HOLLOW
COLUMN W/
THREADED ROD
BRICK TO MATCH
EXISTING
CMU PIERS
LATTICE
1x TRIM, ALIGN TO COLUMN
HARDIE SOFFIT, PAINTED
1x6" FASCIA, PAINTED
1x6 T&G CEILING
PAINTED
STANDING SEAM METAL ROOF
1/2" ZIP SYSTEM SHEATHING W/
BITUMINOUS SECONDARY
ROOF MEMBRANE
1/4" / 12"
REVERSE BOARD & BATTEN
SIDING, HARDIE SMOOTH FEILD,
TRUEXTERIOR AT CORNERS
FLASHING
1/4" GAP W/
INSECT SCREEN
TIMBERTECH DECKING
2x P.T. SILL PLATE
METAL TERMITE SHIELD W/ SILL
GASKET ON BOTH SIDES OF SHIELD
3/4" ADVANTECH FLOOR SHEATHING
FLOOR JOISTS PER STRUCTURAL
#30 ADJ, GUTTER
HANGER & 6" 1/2-
ROUND GUTTER
OPEN CELL FOAM
INSULATION R-30
1/2" DRYWALL
ROOF FRAMING AND
FRAMING TIES PER
STRUCTURAL
ENGINEER
1/4" GAP W/
INSECT SCREEN
1/2" ZIP SYSTEM
SHEATHING
ALL EXTERIOR TRIM TO
BE SMOOTH HARDIE OR
TRUEXTERIOR
2024 All Rights ReservedC
NOT FOR
CONSTRUCTION
5/1/2025 11:45:33 AM
A4.1BUILDING AND WALL SECTIONS
HRB
REVIEW
1107 Prince St. Beaufort, SC
05/01/2025
1/4" = 1'-0"1 Section 2
1/4" = 1'-0"2 Section 3
1" = 1'-0"3 Section 3 - Callout 1
1/8 IN GAP RECOMMENDED
@ PANEL EDGES
ZIP SYSTEM TAPE INSTALLED
OVER ALL JOINTS
OVERLAP TAPE MIN. OF
1 IN. @ ALL T-JOINTS
INSTALL ZIP SYSTEM TAPE OR
ADHESIVE BACKED FLASHING
FROM BOTTOM, SIDES, THEN TOP
TO ENSURE SHINGLE LAP OF
ADHESIVE BACKED FLASHING
2x6 STUDS
INSTALL SOLID BLOCKING
BTWN STUDS AS NEEDED
FOR REQ'D. EDGE NAILING
ENSURE TAPE @ CORNER IS POSITIONED FOR A
MIN. 1-IN. OF CONTACT ON GREEN OVERLAY
SURFACE ON BOTH PANELS. 6-IN. TAPE OR
MULTIPLE PIECES OF 3 3/4-IN. TAPE IS ACCEPTABLE.
1/8 IN. GAP RECOMMENDED
@ PANEL EDGES
ZIP SYSTEM TAPE INSTALLED
OVER ALL PANEL SEAMS
OVERLAP TAPE MIN. OF 1 IN.
@ ALL T-JOINTS
INSTALL BLOCKING BTWN
STUDS AS NEEDED FOR
REQ'D EDGE NAILING
2x6 STUDS, ADDITIONAL STUDS
MAY BE REQ'D TO FASTEN ZIP
SYSTEM @ CORNERS
SHIMS
WALL ASSEMBLY
ZIP SYSTEM SHEATHING
WOOD STUDS
CONTINUOUS PIECE OF
10" WIDE ZIP SYSTEM
STRETCH TAPE
ZIP SYSTEM TAPE OR ADHESIVE
BACKED FLASHING (MUST MEET
AC148 OR AAMA 711) SEALED
OVER WINDOW FLANGES AT
JAMBS
APPLY A CONTINUOUS BEAD
OF SEALANT AROUND THE
FULL PERIMETER OF THE
BACK SIDE (INTERIOR
SURFACE) OF THE WINDOW
MOUNTING FLANGE
THE BEAD OF SEALANT ON THE
MOUNTING FLANGE AT THE SILL
MUST HAVE AT LEAST 2 GAPS AT
LEAST 2 INCHES WIDE TO PERMIT
DRAINAGE. THE GAPS MUST BE
NO MORE THAN 4-FEET APART
INSIDE SURFACE OF
WINDOW FLANGE
SEALANT
WHEN USING ZIP SYSTEM TAPE, BUTYL OR 100% SILICONE SEALANTS ARE
ACCEPTABLE. DO NOT USE LATEX SEALANTS WITH ZIP SYSTEM TAPE. IF USING
ANOTHER FLASHING TAPE, FOLLOW THE FLASHING MANUFACTURER'S
RECOMMENDATION IN SELECTING A SEALANT COMPATIBLE WITH THE FLASHING.
JAMB FLANGE FLASHING
TAPE NOT TO EXTEND PAST
THE MID-POINT OF HEAD
FLANGE FLASHING TAPE
ZIP SYSTEM TAPE
INSTALLED WINDOW
WALL BEYOND
ROOF SHEATHING
ROOF MEMBRANE AS SPECIFIED
METAL ROOF
METAL FLASHING, KICK-OUT
@ CORNER & CONCEAL
UNDER SIDING
METAL BASE FLASHING
SEAL TOP OF FLASHING TO WALL SHEATHING
W/ ZIP SYSTEM FLASHING TAPE
INTERIOR
EXTERIOR
REFER TO ZIP SYSTEM
FLASHING AND RAINSCREEN @
WINDOW AND DOOR DETAILS
EXTERIOR TRIM
HISTORIC SILL (AZEK
AZM-6930)ALIGN BOARDS W/ WINDOWS
BOARD WIDTHS ABOVE AND
BELOW WINDOW TO HAVE
SIMILAR CUSTOM WIDTHS
AND SPACED EVENLY.
REFER TO EXT. ELEVATIONS
2x8 HARDIE TRIM
FLASHING
REVERSE BOARD &
BATTEN SIDING
DO NOT USE CAULK
BETWEEN HEAD
FLASHING AND SIDING
1x6 TRIM, PAINT, U.N.O.
3 1/2"
INTERIOR TRIM
1"
INTERIOR
EXTERIOR
1x4 TRIM, PAINT
TYPICAL
WINDOW JAMB
2024 All Rights ReservedC
NOT FOR
CONSTRUCTION
5/1/2025 11:45:33 AM
A4.2DETAILS
HRB
REVIEW
1107 Prince St. Beaufort, SC
05/01/2025
1/2" = 1'-0"1 ZIP SHEATHING @ TYP. PENETRATIONS
1/2" = 1'-0"2 ZIP SYSTEM SHEATHING @ CORNERS
3/4" = 1'-0"3 ZIP SYSTEM WINDOW FLASHING
1/2" = 1'-0"4 WALL TO METAL ROOF
3" = 1'-0"5 WINDOW AND DOOR DETAILS
J
J J
J
ERV
ELEC.
PANEL
E
SDSD
SD
SD
SD
OFFICE
BEDROOM
2
BATH 2 BATH 1
BEDROOM
1
GREAT
ROOM
SCREENED
PORCH
LAUNDRY/PANTRY
TV
GENERAL CONTRACTOR TO
SCHEDULE AN ELECTRICAL
WALKTHROUGH WITH
ELECTRICIAN, OWNERS, AND
ARCHITECT PRIOR TO ROUGH-IN
TV
TV
+114"
+114"
+80"
+80"
+80"
CEILING FAN
ELECTRIC METER
ELECTRIC PANEL
UTILITY LED
WALL MOUNTED LIGHT FIXTURE
EXHAUST FAN W/ LIGHT
CEILING MOUNTED LIGHT FIXTURE
MOUNTED @ SPECIFIED HEIGHT
DUPLEX ELECTRICAL OUTLET
220 VOLT ELECTRICAL OUTLET
ELECTRICAL WALL SWITCH
ELECTRICAL WALL SWITCH WITH
DIMMER (POLE, AS NOTED)
DUPLEX ELECTRICAL OUTLET
WEATHERPROOF OUTLET,
DUPLEX ELECTRICAL OUTLET
SMOKE DETECTOR, WIRED IN SERIES
DOOR CHIME BUTTON
INTERCOM
LIGHT FIXTURE
VACUUM OUTLET
DOOR CHIME
EXHAUST VENT (SEE SPECS.)
G.F.C.I.
SPLIT WIRED
QUADPLEX OUTLET
G.F.C.I. AS NOTED
JUNCTION BOX
3-WAY ELECTRICAL WALL SWITCH
FLUSH, FLOOR TYPE, ELEC.
OUTLET, (LOCATED BY OWNER)
GFI
WP
+42
TELEPHONE (SEE SPECS FOR BUNDLED
STRUCTURE WIRING REQUUIREMENTS)
TELEVISION (SEE SPECS FOR BUNDLED
STRUCTURE WIRING REQUUIREMENTS)
3 D
J
I
TV
CH
VO
SD
E
RECESSED CAN LIGHT
OCCUPANCY SENSOR (ERV)
EQEQ
3' - 8"
TYP. RECEPTACLE IN
BASEBOARD
TYP. LIGHT
SWITCH
3' - 6"
TYP. RECEPTACLE OVER
COUNTER W/ TILE
BACKSPLASH
+42
3' - 8"
TYP. RECEPTACLE OVER
COUNTER W/ 4"
BACKSPLASH
+44
6"
2024 All Rights ReservedC
NOT FOR
CONSTRUCTION
5/1/2025 11:45:34 AM
E.1
FIRST FLOOR ELECTRICAL
HRB
REVIEW
1107 Prince St. Beaufort, SC
05/01/2025
1/4" = 1'-0"1 FIRST FLOOR ELECTRICAL
1/4" = 1'-0"
ELECTRICAL SYMBOLS
1/2" = 1'-0"2 ELEC. FIXTURE DIAGRAM
Light Fixture Schedule
Fixture Tag Fixture Type Count Manufacturer Model Lamp Comments
C1 CEILING MOUNTED FIXTURE 4 3000 LED UTILITY LIGHT
C2 CEILING MOUNTED FIXTURE 1 PROVIDE D BY OWNER 3000 LED DINING CHANDELIER
F1 CEILING FAN 5 PROVIDED BY OWNER
R1 RECESSED CAN 17 NORA LIGHTING NHI OICD-48 3000 LED TYPICAL CAN LIGHT
R2 RECESSED CAN 2 NORA LIGHTING NHIOICD-48 3000 LED WET RATED
R5 RECESSED CAN 22 NORA LIGH TING 3000 LED SLOPED CEILING
S1 WALL MOUNTED 3 VISUAL COMFORT CRITTENDED MEDIUM 3000 LED TYPICAL EXTERIOR SCONCE
S2 WALL MOUNTED 3 3000 LED FLOOD LIGHTS
S3 WALL MOUNTED 3 PROVIDED BY OWNER 3000 LED TYPICAL BATHROOM SCONCE
T1 LED TAPE 2 WAC PRO+ / OUTDOOR PRO+ 3000 LED
ZE X H A U S T F A N 2
+114"
BEDROOM 1
BEDROOM 2
BEDROOM 3
BATH 1
BATH 2
LAUNDRY
KITCHEN
LIVING
SCREENED PORCH
DINING
FRONT
PORCH
BACK
TERRACE
DEMOLISH
(DASHED LINES, TYP.)
GENERAL CONTRACTOR TO
VERIFY THAT THE EXISTING
WALLS TO BE REMOVED ARE
NON LOAD BEARING PRIOR TO
DEMOLITION. COORDINATE W/
ARCHITECT OR ENGINEER
RAISE EXISTING ROOF STRUCTURE, SEE NEW ELEVATIONS
RAISE EXISTING ROOF STRUCTURE, SEE NEW ELEVATIONS
2024 All Rights ReservedC
NOT FOR
CONSTRUCTION
11/1/2024 10:36:30 AM
.D2.1DEMOLITION PLAN
PRICING
SET
1107 Prince St. Beaufort, SC
2024/11/01
1/4" = 1'-0"1 DEMOLITION PLAN2 EXISTING + DEMO 3D SOUTH EAST
3 EXISTING + DEMO 3D NORTH WEST
8538501-12: Medium One Light Outdoor Wall Lantern
Collection: Crittenden
Supplied with 6.5-inches of wire
For an eco-friendly lighting design, convert to LED bulbs to offer savingsand reduce energy
Designed for damp and wet environments allowing for direct watercontact
1-year manufacturer warranty
ENERGY STAR® Qualified
UPC #:785652002694
Finish: Black (12)
Dimensions:
Width: 10.0"
Height: 8.5"
Weight:1.6 lbs.
Extends:11.375'
Wire:6.5" (color;Black/White)
Mounting Proc.:Cap Nuts
Connection:Mounted To Box
Bulbs:
1 - Medium A19 75.0w Max. 120v Not included
Features:
Dark Sky friendly. Designed to emit no light above the 90°horizontal plane. Photometry unavailable.
Easily converts to LED with optional replacement lamps
Meets Title 24 energy efficiency standards
Title 24 compliant if used with Joint Appendix (JA8) approved lightbulbs listed in the California Energy Commission Appliancedatabase.
Material List:
1 Body - Aluminum - Black
Safety Listing:
Safety Listed for Wet Locations
Instruction Sheets:
English (8438501 8538501 8638501)Trilingual (English, Spanish, and French) (8438501 8538501 8638501)Trilingual (English, Spanish, and French) (990W8538501-CRI)
Backplate / Canopy Details:
Type Height / Length Width Depth Diameter Outlet Box Up Outlet Box Down
Back Plate 0.88 5.0 2.5
Shipping Information:
Package Type Product # QuantityUPC Length Width Height Cube Weight Frt. Class UPS Ship
Individual 8538501-12 1 785652002694 14.0 13.0 11.5 1.21 3.1 0 Yes
Master Pack 8538501-12 0 10785652002691 No
NJ Pallet 54 48.0 40.0 72.0 80.0 167.4 No
NV Pallet 54 48.0 40.0 72.0 80.0 167.4 No
Visual Comfort & Co. reserves the right to revise the design of components of any product due to parts availability or change in safety listing standards without assuming any obligation or
liability to modify any products previously manufactured and without notice. This literature depicts a product design that is the sole and exclusive property of Visual Comfort & Co.. In
compliance with U.S copyright and patent requirements, notification is hereby presented in this form that this literature, or the product it depicts, is not to be copied, altered or used in any
manner without the express written consent of, or contrary to the best interests of Visual Comfort & Co.
www.4mmetals.com
Hawk-Eye Home
Inspections, LLC
15 Sams Point Rd suite 204, Beaufort, SC 29907
Owner/operator:
Lenny Andrews
License #1025
(843) 575-4430
Inspector: Nick Thomson
License # 48847
Inspector: Ryan Goller
License #49250
Inspector: Seth Andrews
License #49620
Attention Realtors
If the sale or transaction of said buyer does not close or falls through then
this report is Not to be Shared with other potential buyers by agents or sellers
without written permission from Hawk-Eye Home Inspections, llc.
This report is nontransferable and is intended for the sole purpose of said (buyer/client) of this inspection.
This report may be shared with anyone within this transaction of this (buyer/client) only.
Hawk-Eye Home Inspections, LLC
15 Sams Point Rd suite 204
Beaufort, SC 29907
843-575-4430
Prepared by: Seth Andrews
Property Inspection Summary
1107 Prince St, Beaufort, SC 29902
Client
Name: Suzanne Previte
Phone: (412)480-5568 Email: previte64@gmail.com
Client's Agent
Name: Sellers Inspection Agency: N/A
Phone: Email:
Major Concern
Condition Deficiency
Exterior HVAC unit/condenser
Finding
HVAC system did not function when tested. The home appears to be heating from the emergency heat strip.
Recommend further evaluation and repair by a HVAC company.
Minor Repair
Roof Penetration, Venting and Flashing Deficiency
Roof
Finding
Rubber seal around the plumbing stacks on the roof shows deterioration and/or is cracked. This could allow water to
penetrate or leak into the attic area. Some cracks can be sealed with roof mastic or tar, while others are too large so the
boot vent will have to be replaced.
Finding
Damaged or missing roof shingles found on the ridge on the roof.
Finding
Improper flashing noted on the roof. Kick outs not installed at the end of the step flashing. This could allow water
behind the siding.
Kickout flashing, also known as diverter flashing, is a special type of flashing that diverts rainwater away from the
cladding and into the gutter. When installed properly, they provide excellent protection against the penetration of water
into the building envelope.
03/07/2024 Hawkeyehome.com 1 of 7
Siding / Wall Coverings Deficiency
Exterior
Finding
Dry rot/water damage found on the wood siding on the screen porch of the home.
Finding
Extensive dry rot/water damage found on the wood siding on the back of the home.
Finding
Dry rot/water damage found on the wood siding on the left side of the home.
Doors and Windows Deficiency
Exterior
Finding
Cracked or hole found in the window pane on the front bedroom of the home.
Finding
Dry rot/water damage found on the bottom of the door casing and/or trim on£the living room of the home.
Finding
Dry rot/water damage found on the exterior sill and/or trim sections of the window located on the kitchen.
Finding
Dry rot/water damage found on the bottom of the door casing and/or trim on£the back of the home.
Finding
Dry rot/water damage found on the exterior sill and/or trim sections of the window located on the left side of the home.
Trim and Eaves Deficiency
Exterior
Finding
Dry rot/water damage found on the soffit and or fascia boards (eaves) on the front porch of the home.
Finding
Dry rot/water damage found on the soffit and or fascia boards (eaves) on the right side of the home.
Finding
Dry rot/water damage found on the corner trim on the£back£corner of the home.
Finding
Dry rot/water damage found on the soffit (eaves) on the£left side of the home.£
Finding
Dry rot/water damage found on the fascia board (eave's) located on the£right side of the home above the roof line.
Windows Deficiency
Interior
Finding
Window track appeared to be broken and/or the springs are worn. Window would not stay in the up position when
tested in the follow areas:£back left bedroom .
1107 Prince St 2024030703
Minor Repair (continued)
03/07/2024 Hawkeyehome.com 2 of 7
Chimney Deficiency
Chimney
Finding
Chimney does not appear to meet today's construction standards. Recommend further evaluation and repair by
licensed builder.
Supply Lines Deficiency
Plumbing
Finding
Active leak noted on the supply line under the front bathroom.£
Waste Lines Deficiency
Plumbing
Finding
Improper reapair noted under the back bathroom sink. Caulk is not an acceptable repair for plumbing.
Water Heater Deficiency
Water Heater
Finding
Water heater did not have a drain pan installed under it. Recommend adding to prevent water damage if the water
heater leaks.
Finding
PVC pipe installed on the water heater pressure relief valve (P&T valve). PVC pipe is not rated for hot water. If the P&T
valve opens the pvc could melt or come apart and cause water damage. Recommend replacing line.
Distribution Deficiency
Exterior HVAC unit/condenser
Finding
HVAC ducts have come apart or been partially removed in the attic. Recommend a licensed HVAC company further
evaluate and determine if repair or replacement is needed.
Crawlspace Deficiency
Foundation
Finding
Water stains noted under the back right corner of the home. Moisture readings show an active leak. Recommend
further evaluation and repair by a licensed plumber.
Safety Concern
Porches, Patios and Decks Deficiency
Exterior
Finding
Handrail (guards) not present on the porches and or stairs. Porches, balconies, ramps, stairs, or raised floor surfaces
1107 Prince St 2024030703
Minor Repair (continued)
03/07/2024 Hawkeyehome.com 3 of 7
located more than 30 inches above grade are required to have guards that are not less than 36 inches in height.
GFCI and Arc Fault Outlets/breakers Deficiency
Electrical
Finding
GFCI outlets not installed in the kitchen. This was not a requirement on homes built before 1987. In 1987 GFCI outlets
are required in the kitchen with in 6 ft of a water source. In 1996 GFCI outlets are required throughout the kitchen. It is
still recommend to install for personal safety.
Smoke Detectors Deficiency
Electrical
Finding
Smoke detectors not installed in the home or not installed in the proper locations.
Water Heater Deficiency
Water Heater
Finding
Electrical disconnect box was not installed for the water heater. Todays construction requires a disconnect box if the
breaker box is not with in view of the water heater.
Condition Deficiency
Exterior HVAC unit/condenser
Finding
Loose conduit found on the electrical disconnect box for the exterior HVAC unit. Exposed electrical wires noted.
General Maintenance
Paint Deficiency
Exterior
Finding
Paint peeling on the exterior surfaces of the home. Chipping, sanding, priming, and painting may be needed. When
paint is peeling, the homeowner needs to properly strip and re-paint. You should always prime again before painting. In
most cases paint will peel off less than a year if not primed. If home was constructed prior to 1979 there is a possibility
of "Lead in the paint chips". Caution should be taken.
Storm Doors, Windows and Screens Deficiency
Exterior
Finding
Screen found torn on the screen porch.
Outlets, Switches and Fixtures Deficiency
Electrical
Finding
Light fixture is hanging by the wire in the£screen porch.
1107 Prince St 2024030703
Exterior (continued)
03/07/2024 Hawkeyehome.com 4 of 7
Plumbing Fixtures Deficiency
Plumbing
Finding
Hose bib faucet is missing a handle or has a broken handle on the home. Unable to test for proper function.
Waste Lines Deficiency
Plumbing
Finding
Active leak found on the drain line under the£kitchen sink.
Tub/Shower, Tub/Shower Walls, Flooring Deficiency
Bathrooms
Finding
Loose toilet noted in the front hall£bathroom. Recommend replacing wax ring in repair.
Condition Deficiency
Exterior HVAC unit/condenser
Finding
The insulation on the suction line to the condensor (exterior HVAC unit) is deteriorated/not installed. The suction line is
the line that connects the condensor to the airhandler (interior HVAC unit),
Ventilation Deficiency
Attic
Finding
Bathroom exhaust was not duct to exterior wall area in the attic. This could allow moisture to build up in the attic.
Foundation support and information Deficiency
Foundation
Finding
Missing or damaged foundation vents noted in several locations on the home. This could allow pest (rodents and
insects) access to the crawlspace.
Crawlspace Deficiency
Foundation
Finding
Excessive opening in the sub floor under the bathrooms. This could allow pest or rodents access.
Cosmetic Repair
Trim and Eaves Deficiency
Exterior
Finding
Dented/ damaged aluminum corner trim noted on several corners.
1107 Prince St 2024030703
General Maintenance (continued)
03/07/2024 Hawkeyehome.com 5 of 7
Walls and Ceilings Deficiency
Interior
Finding
Cosmetic cracks found in the ceiling and walls in several areas.£
Finding
Water stains found on the ceiling or wall throughout the home.£Moisture readings show leak to be an inactive leak (dry)
at the time of inspection.
Finding
Sheetrock has unfinished patch or repair and/or visible repairs located in several areas.
Floors Deficiency
Interior
Finding
Stained carpet found in the bedrooms.
Finding
Tears noted in the vinyl flooring in the kitchen.
Doors Deficiency
Interior
Finding
Doors appear to be delaminating in the back bedroom.
Finding
Pet damage noted to the door/door trim or wall in the back bedroom.
Tub/Shower, Tub/Shower Walls, Flooring Deficiency
Bathrooms
Finding
Cracks found in the bottom of the fiberglass tub/shower. It is not always possible to determine if the cracks are leaking
without putting weight on the damaged area. See crawlspace section for more findings.
Recommendation
Insect Infestation Deficiency
Site
Finding
Insect damage found in the crawlspace. Recommend consulting a pest control company and/or a licensed builder to
determine if repairs are needed.
Fireplace Deficiency
Fireplace
Finding
Soot and/or cresol build up found in the fireplace. Recommend cleaning by a certified chimney sweep.
1107 Prince St 2024030703
Cosmetic Repair (continued)
03/07/2024 Hawkeyehome.com 6 of 7
Crawlspace Deficiency
Foundation
Finding
Debris or old construction material noted in the crawlspace. Recommend removing to prevent attacting insect or pest.
Additional Information
Outlets, Switches and Fixtures Deficiency
Electrical
Finding
Open ground receptacles/outlets found throughout the home. Many are 3-prong outlets that have been upgraded from
2-prong outlets. This is common in older homes or homes with 2 wire ungrounded electrical wires. Recommend
consulting a licensed electrician on proper installation or upgrade.
Chimney Deficiency
Chimney
Finding
Water stain found on the interior of the chimney or side of the chimney (viewed from the attic). Moisture meter
indicated an inactive leak (dry) at the time of inspection.
Crawlspace Deficiency
Foundation
Finding
Water stains noted under the£laundry room£on the sub-floor or framing. Moisture readings show an in-active leak (dry)
at the time of inspection.
Finding
Water stains noted under the£right side of the home£on the sub-floor or framing. Moisture readings show an in-active
leak (dry) at the time of inspection.
1107 Prince St 2024030703
Recommendation (continued)
03/07/2024 Hawkeyehome.com 7 of 7
Hawk-Eye Home Inspections, LLC
15 Sams Point Rd suite 204
Beaufort, SC 29907
843-575-4430
Prepared by: Seth Andrews
Property Inspection Report
1107 Prince St, Beaufort, SC 29902
Client
Name: Suzanne Previte
Phone: (412)480-5568 Email: previte64@gmail.com
Property
Type: Single Family Est. Age: 1940 Main Entry: South
Occupancy: Heavily Occupied
The residence/home was heavily occupied. According to states standards of practice a residental home inspection is limited
to readily accessible area's. Heavily occupied homes have many area's that are obstructed from view and/or area's that are
not accessible for inspection. The cleanliness or lack of may hide defects/concerns in the home. Inspector does not list all the
area's that have not been inspected on a heavily occupied home.
Inspection
03/07/2024 Hawkeyehome.com 1 of 33
Number: 2024030703 Date: 03/07/2024 Arrival Time: 9:00 AM Departure Time: 11:00 AM
Est. Temperature: 60°F Weather: Cloudy Fee: 475.00 Payment Type: Venmo
Type: Full
Client's Agent
Name: Sellers Inspection Agency: N/A
Phone: Email:
Site
General Condition Satisfactory
State of Property: Below Average or
poor
Below Average or poor:
It is the inspectors opinion that the general condition of this home is "below average or poor". Inspector noted many
repairs and/or expensive repairs needed to bring this home up to an average condition. Inspector does not report all
deficiencies and or damage when a home is stated in "poor condition". Inspector may make a general reference or
group damage under one finding.
This report is intended as a general guide to help the client make his or her own evaluation of the property being
inspected.
The inspection is not intended to reflect the value of the premises, nor make any representation as to the advisability
of the purchase. The report expresses the personal opinion of the inspector, based upon his visual impressions of
the home that exist at the time of the inspection only. The inspection and reports are not intended to be technically
exhaustive, or imply that every component was inspected, or that every possible defect was discovered. No
disassembly of equipment, opening of walls, moving of furniture, appliances, or stored items, or excavation was
performed. All components and conditions which by nature of their location are concealed, camouflage, or difficult
to inspect are excluded from the report.
Systems, items and conditions which are not within the scope of the home inspection include, but are not limited to:
radon, formaldehyde, lead paint, asbestos, toxic or flammable material, other environmental hazards, pest
infestation, security and fire protection systems, household appliances, humidifiers, paint, wall paper and other
treatments to windows, recreational or playground equipment, underground storage tanks, energy efficiency
measurements, cooling equipment, internal or underground drainage or plumbing, any system which are shut down
or otherwise secured, water wells, zoning ordinances, concealed or private secured systems, heating system
accessories, solar heating system, irrigation systems, eater softener, central vacuum system, telephone, intercom,
cable TV systems, heating sensors, lightning arrestors, trees or plants, codes, ordinance statutes and covenants for
cosmetic or code conformity. Client understands that the above mentioned items are excluded from this inspection
and any comments about these systems on the conditions are informal only and do not represent a thorough
inspection.
The report/inspection is not intended to be a warranty or guarantee of the present or future adequacy or
performance of the structure, its systems, or their components. Any opinions expressed regarding adequacy,
capacity, or expected life of component are a general estimates based on information about similar components and
occasion wide variations are to be expected between such estimates and actual experience.
The inspection and report are performed and prepared for the sole and exclusive use and possession of client, home
inspector, and designated agents. No other person or entity may rely on this report issued pursuant to this
1107 Prince St 2024030703
03/07/2024 Hawkeyehome.com 2 of 33
agreement. The client further agrees that the inspector is liable only up to the cost of the inspection and only if there
has been a failure to follow the states standards of practice.
The pictures in this report are representative in nature. Pictures do not necessarily depict all damage of a given
deficiency. Photographs of all the observed damage/deficiency may not be included in this report.
Plot Elevation Satisfactory
Plot elevation is the slop of the land next to the home.£
Slope: Negative Front Retaining Walls: No
Negative Front:
This inspection is not intended to address or include any geological conditions or site stability information. For
information concerning these conditions, a geologist or soils engineer should be consulted. Any reference to grade
is limited to only areas around the exterior of the exposed areas of foundation or exterior walls. This inspection is
visual in nature and does not attempt to determine drainage performance of the site or the condition of any
underground piping, including municipal water and sewer service piping or septic systems. Decks and porches are
often built close to the ground, where no viewing or
access is possible. These areas as well as others too low to enter, or in some other manner not accessible, are
excluded from the inspection and are not addressed in the report. We routinely recommend that inquiry be made
with the seller about knowledge of any prior foundation or structural repairs.
Driveway Satisfactory
A driveway is a type of private road for local access to one or a small group of structures, and is owned and
maintained by an individual or group.
Type: Dirt
Sidewalks Satisfactory
A sidewalk, pavement, footpath, or footway, is a path along the side of a road. Usually constructed of concrete or
asphalt, it is designed for pedestrians. A sidewalk may accommodate moderate changes in grade and is normally
separated from the vehicular section by a curb.
Type: Dirt
Landscaping Satisfactory
Overgrown vegetation can limit the inspector's visibility for a thorough inspection as well as could cause
water/moisture damage to the wood surfaces of the home. Recommend keeping vegetation trimmed at least 3 feet
from the home.
Tree's in close proximity to the home could cause damage to roofs as well as foundations.
According to the states standards of practice excavation is not allowed. Inspector does not report if tree's are in
close proximity to the home. Inspector does not report root damage.
Insect Infestation Deficiency
Inspector does not provide a CL100 report or infestation report. Inspector will report insect damage if visible.
Status: Damage found
Damage found:
Recommendation
Insect damage found in the crawlspace. Recommend consulting a pest control company and/or a licensed builder to
1107 Prince St 2024030703
General Condition (continued) Satisfactory
03/07/2024 Hawkeyehome.com 3 of 33
determine if repairs are needed.
Roof
1107 Prince St 2024030703
Insect Infestation (continued) Deficiency
03/07/2024 Hawkeyehome.com 4 of 33
Construction Satisfactory
Style: Gable Skylights: No Roof was viewed/inspected from:
Walked
Gable:
Gabled roofs are the kind young children typically draw. They have two sloping sides that come together at a ridge,
creating end walls with a triangular extension, called a gable, at the top.
Walked:
Inspector was able to walk this roof for the inspection.
Material Satisfactory
The inspection of the roof is a visual inspection on the condition of the roofing material at the time of the inspection
only. When aging a roof it is based on the actual wear of the material, which may be different then the actual age
itself. The inspector does not offer a warranty or opinion on if the roof is leaking. Often it takes a prolong rain fall to
determine if the roof is absolutely water tight. When the report indicates that a roof is "satisfactory", that means it is
satisfactory for its age and general usefulness. A roof that is stated to be satisfactory may show evidence of past
leaks or may develop leaks. However, such a roof can be repaired and give generally satisfactory service within the
limits of its age.£
Viewing the shingles will not be able to determine the exact type or years selected by the installer. Shingles start
usually at a 15 year warranty and go up to 40 year warranty. Most shingles that have black streaks in them are the
algae protection starting to deteriorate. Some shingles do not have the protection in them at all. The inspector will
not be able to determine that during their inspection. These areas can be treated and cleaned off during the early
stages of deterioration.
Type: Composition Architectural
Shingle
Approximate Age: 15-20 years Layers: 1 layer
Composition Architectural Shingle:
Architectural roof shingle are a newer generation of high quality asphalt roofing product. The major benefit of this
shingle is its life span. The average architectural shingle can last 25 to 35 years.
1 layer:
Inspector noted 1 Layer or roof shingles on this home. This is normal construction practice.£
On the surface, a roof looks like a simple layering of tiles, shingles, or slate. But it is a complex system composed of
multiple layers of different materials designed to withstand forces of nature outside while helping you control
humidity and temperature levels inside.
Roof Penetration, Venting and Flashing Deficiency
Penetrations and venting: Plumbing
Stacks, Roof vents
Flashing: Visible
Plumbing Stacks:
Plumbing stacks are installed through the roof to allow sewage gas to escape into the air. All plumbing waste
fixtures (tubs/showers, sinks, toilets, etc.) use traps to prevent sewer gases from leaking into the house. Through
these traps, all fixtures are connected to waste lines. Plumbing stacks also allow air into the waste lines to allow
proper flow of discharge waste water.£
1107 Prince St 2024030703
Insect Infestation (continued) Deficiency
03/07/2024 Hawkeyehome.com 5 of 33
Visible:
Roof flashing was visible for inspection. Some areas may not have been visible do to roof shingles or siding.
Inspector only inspects visible areas.
Minor Repair
Rubber seal around the plumbing stacks on the roof shows deterioration and/or is cracked. This could allow water to
penetrate or leak into the attic area. Some cracks can be sealed with roof mastic or tar, while others are too large so the
boot vent will have to be replaced.
Minor Repair
Damaged or missing roof shingles found on the ridge on the roof.
Minor Repair
Improper flashing noted on the roof. Kick outs not installed at the end of the step flashing. This could allow water
behind the siding.
Kickout flashing, also known as diverter flashing, is a special type of flashing that diverts rainwater away from the
cladding and into the gutter. When installed properly, they provide excellent protection against the penetration of water
into the building envelope.
1107 Prince St 2024030703
Roof Penetration, Venting and Flashing (continued) Deficiency
03/07/2024 Hawkeyehome.com 6 of 33
Gutters and Downspouts Satisfactory
A gutter is a trough along the eaves to catch and carry off rainwater.The gutter carries the run-off water from the
roof to an opening, which then directs the water down the downspout. The downspout is usually found at a corner
of the house, although this isn’t always the case. At ground level, the downspout should have a bend or elbow,
which would carry the water away from the house.
Type: PVC Leaf guard: No
Structure
Dwelling Satisfactory
Type: Single Family Construction: Wood Frame
Single Family:
A house that is occupied by not more than one family or a detached building consisting of one dwelling unit that is
occupied or intended to be occupied as the home or residence of one family.
Wood Frame:
Wood frame construction means that the core structure of the home is built mostly of lumber/wood.
Exterior
Siding / Wall Coverings Deficiency
Siding or wall cladding is the protective material attached to the exterior side of a wall of a house or other building.
Type: OSB/Hardwood, Plywood (T-
111 siding), Aluminum
OSB/Hardwood:
OSB (Oriented Strand Board) siding is a wood panel manufactured with strands of wood layered for increase
strength. The strands are coated with a binder and bounded under heat and pressure. Hardboard siding is made
using fine grain saw dust and wood waste product combined with a resin under heat and pressure. These siding
products tend to buckle, deteriorate prematurely, delaminate, swell, and harbor fungus. Both materials are involved
with a class-action lawsuit (unsettled at this time). Recommend consulting the manufacturer. Additional information
is available on the internet.
Minor Repair
Dry rot/water damage found on the wood siding on the screen porch of the home.
1107 Prince St 2024030703
Roof Penetration, Venting and Flashing (continued) Deficiency
03/07/2024 Hawkeyehome.com 7 of 33
Minor Repair
Extensive dry rot/water damage found on the wood siding on the back of the home.
Minor Repair
Dry rot/water damage found on the wood siding on the left side of the home.
Doors and Windows Deficiency
A door is a hinged or otherwise movable barrier that allows ingress into and egress from an enclosure. The created
opening in the wall is a doorway or portal. A door's essential and primary purpose is to provide security by
controlling access to the doorway.
£
A window is an opening in a wall, door, or roof that allows the exchange of light and may also allow the passage of
sound and sometimes air.
1107 Prince St 2024030703
Siding / Wall Coverings (continued) Deficiency
03/07/2024 Hawkeyehome.com 8 of 33
Minor Repair
Cracked or hole found in the window pane on the front bedroom of the home.
Minor Repair
Dry rot/water damage found on the bottom of the door casing and/or trim on£the living room of the home.
Minor Repair
Dry rot/water damage found on the exterior sill and/or trim sections of the window located on the kitchen.
Minor Repair
Dry rot/water damage found on the bottom of the door casing and/or trim on£the back of the home.
1107 Prince St 2024030703
Doors and Windows (continued) Deficiency
03/07/2024 Hawkeyehome.com 9 of 33
Minor Repair
Dry rot/water damage found on the exterior sill and/or trim sections of the window located on the left side of the home.
Trim and Eaves Deficiency
The finish materials on the exterior of a building, such as moldings applied around openings (window trim, door
trim), siding, windows, exterior doors, attic vents, crawl space vents, shutters, etc. Also, the physical work of installing
these materials.
Cosmetic Repair
Dented/ damaged aluminum corner trim noted on several corners.
Minor Repair
Dry rot/water damage found on the soffit and or fascia boards (eaves) on the front porch of the home.
1107 Prince St 2024030703
Doors and Windows (continued) Deficiency
03/07/2024 Hawkeyehome.com 10 of 33
Minor Repair
Dry rot/water damage found on the soffit and or fascia boards (eaves) on the right side of the home.
Minor Repair
Dry rot/water damage found on the corner trim on the£back£corner of the home.
Minor Repair
Dry rot/water damage found on the soffit (eaves) on the£left side of the home.£
1107 Prince St 2024030703
Trim and Eaves (continued) Deficiency
03/07/2024 Hawkeyehome.com 11 of 33
Minor Repair
Dry rot/water damage found on the fascia board (eave's) located on the£right side of the home above the roof line.
Paint Deficiency
The inspector will inspect and report the observed condition of the paint on the exterior of the home.
General Maintenance
Paint peeling on the exterior surfaces of the home. Chipping, sanding, priming, and painting may be needed. When
paint is peeling, the homeowner needs to properly strip and re-paint. You should always prime again before painting. In
most cases paint will peel off less than a year if not primed. If home was constructed prior to 1979 there is a possibility
of "Lead in the paint chips". Caution should be taken.
Porches, Patios and Decks Deficiency
Inspector will inspect and report any defects on attached porches, decks and/or balconies.
Type: Concrete Steps: Brick
Concrete:
Concrete patios or porches are long lasting and hold up well to harsh weather extremes. Concrete can be poured,
colored, and stamped to replicate almost any type of stone or brick. Easy to clean and maintain.
Safety Concern
Handrail (guards) not present on the porches and or stairs. Porches, balconies, ramps, stairs, or raised floor surfaces
located more than 30 inches above grade are required to have guards that are not less than 36 inches in height.
1107 Prince St 2024030703
Trim and Eaves (continued) Deficiency
03/07/2024 Hawkeyehome.com 12 of 33
Storm Doors, Windows and Screens Deficiency
General Maintenance
Screen found torn on the screen porch.
Electrical
Incoming Service Satisfactory
Inspector will Identify and report the location of the incoming electrical service.
Most homes have an electrical service of between 100 to 200 amps. Amperage is a measurement of the volume of
electricity flowing through wires, and this measurement can vary between 30 amps in very old homes that have not
been updated to as much as 400 amps in a very large home with extensive electric heating systems
Size: 200 Amp Wire: #3 Incoming Service: Overhead left side
200 Amp:
Main Panel Satisfactory
Electrical panel is a component of an electricity supply system that divides an electrical power feed into subsidiary
circuits while providing a protective fuse or circuit breaker for each circuit in a common enclosure.£
The electrical panel should be properly marked for which circuit it covers, however an inspector cannot determine if
this legend is accurate during a normal home inspection. Recommend determining each validity of each breaker.
1107 Prince St 2024030703
Porches, Patios and Decks (continued) Deficiency
03/07/2024 Hawkeyehome.com 13 of 33
Inspector cannot be held liable for missing labeled breakers/fuses. Any rust or burned areas should be reviewed by a
licensed electrician for repairs.
£
Electrical panels should have a minimal clearance of 36 inches in front of the panel. Inspector will not be able to
access the panel with less then minimal clearance.£
£
£
£
£
Location: Bedroom Closet Type: Breakers Ground Wire: Unknown or not visible
Service Conductors Satisfactory
Service conductors are the conductors from the service point to the service disconnecting means. Note that these
service conductors only originate from the supplying utility side. "Service conductors" is a generic term and may
include service drops, service laterals, and service-entrance conductors
Main: Aluminum Branch Circuits: Copper
Aluminum:
Braided or stranded aluminum wiring is commonly used in SEC (service entrance cables). Aluminum wire is a good
conductor of electricity and less expensive then copper.£
£
Copper:
Copper wire is a single electrical conductor made of copper. It can be insulated or uninsulated. ... Copper wire and
cable is used in power generation, power transmission, power distribution, telecommunications, electronics circuitry,
and countless types of electrical equipment.
Outlets, Switches and Fixtures Deficiency
Inspector shall test a representative number of receptacles, switches, and installed light fixtures. Not all exterior light
will be tested. Some exterior light are on a£
Type of Outlets: 3 prong outlets
(open ground outlets)
Fixtures: Good
3 prong outlets (open ground outlets):
3 Prong with "open ground" outlets noted in this home. This is improper/unsafe installation of a three prong outlet.
The reason this is improper/unsafe is that although the outlet appears to be grounded, it is not. Plugging in a device
that requires a grounding conductor for safety creates a potentially unsafe condition. The third prong provides a
path to ground which the electric current travels. Most major appliances, such as refrigerator, computers, televisions,
etc... have three prong plugs, meaning they must be grounded through the outlet. Failure to provide a path to
ground could cause electrical shock and/or possible damage to the equipment. Three prong open ground outlets
are common in older homes. Many home owners like to change the outlet over from two prong outlets to avoid
using an adapter.
General Maintenance
Light fixture is hanging by the wire in the£screen porch.
1107 Prince St 2024030703
Main Panel (continued) Satisfactory
03/07/2024 Hawkeyehome.com 14 of 33
Additional Information
Open ground receptacles/outlets found throughout the home. Many are 3-prong outlets that have been upgraded from
2-prong outlets. This is common in older homes or homes with 2 wire ungrounded electrical wires. Recommend
consulting a licensed electrician on proper installation or upgrade.
GFCI and Arc Fault Outlets/breakers Deficiency
A ground fault circuit interrupter (GFCI) outlet is for protection against electrical shock in wet areas. It monitors the
amount of current flowing between the hot and neutral. If there is any imbalance, it trips the circuit. GFCI protection
should be installed in the bathrooms, kitchens, exterior of home, garage and within six feet of any water source.
Recommend testing monthly.
£
An arc-fault circuit interrupter (AFCI) also known as an arc-fault detection device is a circuit breaker that breaks the
circuit when it detects an electric arc in the circuit it protects to prevent electrical fires. An AFCI selectively
distinguishes between a harmless arc (incidental to normal operation of switches, plugs, and brushed motors), and a
potentially dangerous arc (that can occur, for example, in a lamp cord which has a broken conductor).
£
AFCI breakers have been required for circuits feeding electrical outlets in residential bedrooms by the electrical
codes of the United States since the beginning of the 21st century; the U.S. National Electrical Code has required
them to protect most residential outlets since 2014.
£
In the USA, arc faults are one of the leading causes for residential electrical fires. Each year in the United States, over
40,000 fires are attributed to home electrical wiring. These fires result in over 350 deaths and over 1,400 injuries each
year.
£
1107 Prince St 2024030703
Outlets, Switches and Fixtures (continued) Deficiency
03/07/2024 Hawkeyehome.com 15 of 33
Conventional circuit breakers only respond to overloads and short circuits, so they do not protect against arcing
conditions that produce erratic, and often reduced current. An AFCI is selective so that normal arcs do not cause it to
trip. The AFCI circuitry continuously monitors the current and discriminates between normal and unwanted arcing
conditions. Once detected, the AFCI opens its internal contacts, thus de-energizing the circuit and reducing the
potential for a fire to occur.
Safety Concern
GFCI outlets not installed in the kitchen. This was not a requirement on homes built before 1987. In 1987 GFCI outlets
are required in the kitchen with in 6 ft of a water source. In 1996 GFCI outlets are required throughout the kitchen. It is
still recommend to install for personal safety.
Smoke Detectors Deficiency
A smoke detector should be installed in every living quarter. In older homes smoke detectors are usually installed in
the hallways only. Recommend adding additional smoke detector if the home does not have one in every living
quarter. The inspector does not report the number of smoke detectors or if each living quarter has one.£
Because alarm sensors wear out, it is recommended to replace each alarm at least every 10 years. Also, alarms have
labels showing when they were made. If you don't see a label, the alarm is old and should be replaced. Most fire
departments will test and check the age of the smoke detector at no charge.
Recommend testing smoke detectors every six months.
Additional note:
If the smoke or carbon monoxide detector is or appears to be connected to an alarm or security company they will
not be tested by the home inspector.
Safety Concern
Smoke detectors not installed in the home or not installed in the proper locations.
Interior
Walls and Ceilings Deficiency
Inspector will report the observed condition.
Cosmetic Repair
Cosmetic cracks found in the ceiling and walls in several areas.£
1107 Prince St 2024030703
GFCI and Arc Fault Outlets/breakers (continued) Deficiency
03/07/2024 Hawkeyehome.com 16 of 33
Cosmetic Repair
Water stains found on the ceiling or wall throughout the home.£Moisture readings show leak to be an inactive leak (dry)
at the time of inspection.
Cosmetic Repair
Sheetrock has unfinished patch or repair and/or visible repairs located in several areas.
Floors Deficiency
Inspector will report the observed conditions of the floor.
Types: Carpet, Vinyl
Carpet:
Where Carpeting has been installed, the materials and condition of the floor underneath cannot be determined.
Cosmetic Repair
Stained carpet found in the bedrooms.
Cosmetic Repair
Tears noted in the vinyl flooring in the kitchen.
Windows Deficiency
Inspector will operate a representative number of windows and at least one window in each sleeping area and report
the observed conditions.
The inspector will not move furniture or owners possessions to access the windows.£
1107 Prince St 2024030703
Walls and Ceilings (continued) Deficiency
03/07/2024 Hawkeyehome.com 17 of 33
Type: Single Hung Frame: Wood Glass: Single Pane
Wood:
Wood windows offer the best insulative value, though they also require more upkeep than vinyl, wood-clad or
aluminum frames. Because of the potential for rot, they may not be the best choice for extremely humid or rainy
climates.
Single Pane:
Single-pane windows are made with a single layer of glass. They come in all of the same styles and materials that
double-pane windows do. Single-pane glass windows have no insulation, when you have only one pane of glass,
outside temperatures and noise will affect the inside of your building more easily.
Minor Repair
Window track appeared to be broken and/or the springs are worn. Window would not stay in the up position when
tested in the follow areas:£back left bedroom .
Doors Deficiency
Inspector shall operate all accessible doors and report the observed condition.
£
The inspector will not move furniture or owners possessions to access the doors.
Type: Solid
Cosmetic Repair
Doors appear to be delaminating in the back bedroom.
Cosmetic Repair
Pet damage noted to the door/door trim or wall in the back bedroom.
1107 Prince St 2024030703
Windows (continued) Deficiency
03/07/2024 Hawkeyehome.com 18 of 33
Environmental Satisfactory
The Inspector does not test, report, or inspect for types of mold, mildew, and/or moisture. On properties with stucco
exteriors it is recommend to have a moisture test.£
Inspector will recommend further testing or evaluation if there is visible signs of what would appear to be mold.
Mold: Not tested Lead paint: Not tested Radon: Not tested
Not tested:
Not tested:
Lead paint was used on homes prior to 1979. Recommend testing if this home was built before 1979 for personal
safety.
Fireplace
Fireplace Deficiency
Fire places that are blocked by personal items or if the inspector could not open the damper door to inspect would
have limited the inspection to the fire place area only. We recommend having this further evaluated by a
professional chimney sweep prior to use of fire place.
The inspector does not light a fire in the fireplace.
Type: Wood Stove Fire Logs: Not present
Recommendation
Soot and/or cresol build up found in the fireplace. Recommend cleaning by a certified chimney sweep.
1107 Prince St 2024030703
Doors (continued) Deficiency
03/07/2024 Hawkeyehome.com 19 of 33
Chimney
Chimney Deficiency
A chimney is an architectural ventilation structure made of masonry, clay or metal that isolates hot toxic exhaust
gases or smoke produced by a boiler, stove, furnace, incinerator or fireplace from human living areas
Chimneys are inspected visually by the inspector.£
It is recommended to have a yearly inspection and a chimney cleaning done every year as well, especially if they use
their fireplace on a regular basis. Other venting systems connected to furnaces and stoves should also be cleaned on
a regular basis to maintain safer operation.
Type: Masonry Liner: Metal Pipe Flashing: Aluminum
Minor Repair
Chimney does not appear to meet today's construction standards. Recommend further evaluation and repair by
licensed builder.
Additional Information
Water stain found on the interior of the chimney or side of the chimney (viewed from the attic). Moisture meter
indicated an inactive leak (dry) at the time of inspection.
Kitchen
Appliances Satisfactory
1107 Prince St 2024030703
Fireplace (continued) Deficiency
03/07/2024 Hawkeyehome.com 20 of 33
Only fixed appliances are inspected or tested. Any reference to a non fixed appliance is as a courtesy only. Inspector
will do a visual inspection of fixed appliances. Inspector will run a cycle on a dishwasher and inspect for leaks. The
garbage disposal will be tested.£
Limitations:
The inspector does not:
£ £ £1. Calibrate temperatures to determine if the oven heat temperature corresponds to the control setting.
£ £ £2. Determine the efficiency of any equipment.£
£ £ £3. Determine the remaining life of any equipment.£
£ ££
Type: Refrigerator, Range Hood
Refrigerator:
Refrigerators have a normal life of 15 to 20 years.
Stove Satisfactory
A stove is a device that burns fuel or uses electricity to generate heat inside or on top of the apparatus. It has seen
many developments over time and serves the main purpose of cooking food. There are many types of stoves, such
as the kitchen stove, the wood-burning stove or the coal stove
Ranges and ovens have a normal life of 15 to 20 years.
Stove Top: Electric Oven: Electric
Cabinets and Counter Tops Satisfactory
A cabinet is a case or cupboard with shelves and/or drawers for storing or displaying items. Some cabinets are stand
alone while others are built in to a wall or are attached to it like a medicine cabinet. Cabinets are typically made of
wood, coated steel, or synthetic materials.
A countertop, also counter top, counter, benchtop, worktop or kitchen bench, is a raised, firm, flat, and horizontal
surface. They are built for work in kitchens or other food preparation areas, bathrooms or lavatories, and workrooms
in general.
Inspector will report observed condition.
Cabinets: Wood Countertops: Formica/laminate
Formica/laminate:
Often associated with Formica and other cheap countertops that rose to popularity in the Fifties and Sixties, laminate
countertops are made from layers of plastic that are bonded to particleboard or kraft paper to create a strong solid
countertop surface
Flooring Satisfactory
Type: Vinyl
Plumbing
Water Supply Satisfactory
Water supply is the provision of water by public utilities, commercial organisations, community endeavors or by
1107 Prince St 2024030703
Appliances (continued) Satisfactory
03/07/2024 Hawkeyehome.com 21 of 33
individuals, usually via a system of pumps and pipes. Public water supply systems are crucial to properly functioning
societies. These systems are what supply drinking water to populations around the globe.
Type: Public Main Shutoff: In Meter Box Meter Location: Front Yard
Public:
This home was noted as "public" for the water supply. Public water supply is defined as a system that provides water
via piping or other constructed conveyances to the public for human consumption.
Supply Lines Deficiency
A supply line, also known as a water supply line is a metal or plastic water line that helps transfer water from the
main line to essential home fixtures, including showers, sinks, and toilets
Type: Copper, Galvanized, Pex
plumbing
Minor Repair
Active leak noted on the supply line under the front bathroom.£
Water Pressure and drainage Satisfactory
Water pressure typically from city water supply systems are from 40 PSI to 70 PSI. On Well systems, especially older
wells the PSI is between 20 -40 PSI. In some cases this can be raised if the well pump can handle the increase.
Plumbing Fixtures Deficiency
Outdoor faucets are conventional cold water supply valves, typically. During the winter months, the water supply
should be shut off by another valve in the building interior to prevent freezing. There are freeze protection external
covers available at local home improvement stores.
General Maintenance
Hose bib faucet is missing a handle or has a broken handle on the home. Unable to test for proper function.
1107 Prince St 2024030703
Water Supply (continued) Satisfactory
03/07/2024 Hawkeyehome.com 22 of 33
Washer and Dryer area Satisfactory
Wash machines and dryers are not tested as part of the home inspection. Only fixed appliances are tested/inspected.
Most washer and dryers have an average life of 15 years. A dryer must be vented to the exterior of the home to
prevent excessive moisture and lint in the home or crawlspace. Lint is considered a fire safety concern.
Location: Closet
Waste system Satisfactory
It is the opinion of the home inspector based on above ground visual evidence on the type of waste system.
Generally if a clean out is in the back yard it is assumed to be on a septic tank. If it is in the front yard it would
appear to be on city sewage. It is up to the client to confirm what type of waste system home is on.
Drain lines on the Washer Machine location are not inspected or tested for clogs during the inspection. Advise that
you monitor your first few loads of laundry after connection has been made. Sometimes these lines are partially
clogged and allow the water to flow just over the top of the pipe, which allows the water to run down the inside of
the wall. This can cause damage to the structure of the home over long periods of time if neglected.
Type: Unknown
Unknown:
If there is no visible evidence of a sewage system inspector will report as unknown.
Waste Lines Deficiency
Clogs often develop at traps because the tight corners tend to collect foreign material. Traps should be arranged so
that they can be removed easily to clear obstructions. These are common spots for obstructions. The waste line
outside the house is also vulnerable to tree roots. Where the pipe has not been seriously damaged, a plumber's
snake may clear a blockage.
Drain lines on the Washer Machine location are not inspected or tested for clogs during the inspection. Advise that
you monitor your first few loads of laundry after connection has been made. Sometimes these lines are partially
clogged and allow the water to flow just over the top of the pipe, which allows the water to run down the inside of
the wall. This can cause damage to the structure of the home over long periods of time if neglected.
Type: PVC, Cast Iron
PVC:
Should have a long dependable life. Easy to repair. Caustic chemicals could dissolve or damage the plastic.
General Maintenance
Active leak found on the drain line under the£kitchen sink.
1107 Prince St 2024030703
Plumbing Fixtures (continued) Deficiency
03/07/2024 Hawkeyehome.com 23 of 33
Minor Repair
Improper reapair noted under the back bathroom sink. Caulk is not an acceptable repair for plumbing.
Water Heater
Water Heater Deficiency
The life expectancy of a water heater is typically twelve to fifteen years. Gas water heaters heat faster than electrical
water heaters giving a quicker recovery time. Thermostats control the water temperature. Most water heaters are set
at 125 degrees. To save energy and avoid burns, 115 to 125 degrees is a recommended setting. If water temperature
exceeds 130 degrees inspector will write it up.
The temperature/pressure relief valve lets water escape if the temperature or pressure is too high. This valve should
be connected to a tube which discharges 6 to 12 inches above floor level so hot water won't be sprayed on to
anyone nearby. The tube discharge should be duct to the exterior of the home.
Type: Electric Approximate Size: 38 Gallons Approximate Age: 3-5 Years (2019)
Location: Closet
Minor Repair
Water heater did not have a drain pan installed under it. Recommend adding to prevent water damage if the water
heater leaks.
1107 Prince St 2024030703
Waste Lines (continued) Deficiency
03/07/2024 Hawkeyehome.com 24 of 33
Minor Repair
PVC pipe installed on the water heater pressure relief valve (P&T valve). PVC pipe is not rated for hot water. If the P&T
valve opens the pvc could melt or come apart and cause water damage. Recommend replacing line.
Safety Concern
Electrical disconnect box was not installed for the water heater. Todays construction requires a disconnect box if the
breaker box is not with in view of the water heater.
Bathrooms
Location, Type, Ventilation Satisfactory
Location: Front Hallway Type: Full Ventilation: Exhaust Fan
Tub/Shower, Tub/Shower Walls, Flooring Deficiency
1107 Prince St 2024030703
Water Heater (continued) Deficiency
03/07/2024 Hawkeyehome.com 25 of 33
Tub/Shower: Tub/Shower Tub/Shower Walls: Fiberglass Flooring: vinyl
vinyl:
Sheet vinyl flooring is vinyl flooring that comes in large, continuous, flexible sheets. A vinyl sheet floor is completely
impermeable to water, unlike vinyl floor tile, which comes in stiff tiles, and vinyl planks, which come in interlocking
strips
General Maintenance
Loose toilet noted in the front hall£bathroom. Recommend replacing wax ring in repair.
Cosmetic Repair
Cracks found in the bottom of the fiberglass tub/shower. It is not always possible to determine if the cracks are leaking
without putting weight on the damaged area. See crawlspace section for more findings.
Bathrooms #2
Location, Type, Ventilation Satisfactory
Location: Back Hallway Type: Full Ventilation: Exhaust Fan
Tub/Shower, Tub/Shower Walls, Flooring Satisfactory
Tub/Shower: Tub/Shower Tub/Shower Walls: Fiberglass Flooring: vinyl
vinyl:
Sheet vinyl flooring is vinyl flooring that comes in large, continuous, flexible sheets. A vinyl sheet floor is completely
impermeable to water, unlike vinyl floor tile, which comes in stiff tiles, and vinyl planks, which come in interlocking
strips
Interior HVAC unit Airhandler/furnace
Make & Model#, Location and Type Satisfactory
Make: Rudd/Rheem Model Number: Unknown Location: Attic
Type: Split system (gas furnace/heat
pump)
Split system (gas furnace/heat pump):
A furnace is an appliance in your home that heats the space through the circulation of hot air.£
Natural gas or propane is ignited in the burner. The flames heat up a metal heat exchanger and exhaust out of the
1107 Prince St 2024030703
Tub/Shower, Tub/Shower Walls, Flooring (continued) Deficiency
03/07/2024 Hawkeyehome.com 26 of 33
flue. The heat exchanger transfers its heat to the incoming air. The furnace's blower forces the heated air into the
ductwork and distributes it throughout the home.
A heat pump is a device that transfers thermal energy from a heat source to a heat sink. Most heat pumps are split
system (one coil on the interior and one on the outside of the home). Heat pumps are one of the most efficient
systems to heat and cool a home. Heat pumps use refrigeration instead of fuel combustion to heat and cool. When a
heat pump is used in heating, it uses the same basic refrigeration-type cycle as in air conditioning, but releases the
heat into the home instead of the surrounding environment. In this use, heat pumps draw heat from the cooler
external air. Reversible heat pumps are designed to work in either direction, in order to provide heating or cooling to
the internal space. They operate by changing which coil is the condenser and which is the evaporator coil. Most units
have a normal life of 10 to 12 years. Units should be serviced at least once a year. Air flow is more critical with heat
pumps than other type of HVAC systems. The filters should be changed every thirty days. Inspector performs a visual
inspection of the units only. No disassembly of equipment or diagnostic of equipment is allowed by states standards
of practice. It is always recommended to have a licensed HVAC company further evaluate units (especially if unit is
over 10 years of age). Heating systems is not tested if the outside air temperature is above 85 degree's Fahrenheit at
the time of the inspection, or if the cooling system was already on and running. Switching between heating and
cooling cycle could damage internal parts. It is common for mold and/or mildew growth (black growth) on HVAC
units in the attic, crawlspace, or closets. It is not possible to determine if or the type of mold/mildew or dust without
further testing. Inspector only report if black growth appears excessive at the time of inspection.
Fuel Source, Approximate Size and Age Satisfactory
Fuel Source: Gas Approximate Size: Rating not
available
Approximate Age: Unknown
Gas:
Gas fired furnaces have a normal life of 15-20 years.
Condition Satisfactory
tested: Not Tested
Exterior HVAC unit/condenser
Make & Model#, Location and Type Satisfactory
Make: Rudd Model Number: Unknown Location: Left-side of Home
Type: Heat Pump
Heat Pump:
When the heat pump is working to cool your home, the duct and fans bring the warm air in the home to the
compressor unit. The compressor unit then uses the same gas evaporation/compression process it uses to heat the
home, but in reverse (removes the heat from the home). Heat pumps are one of the most efficient ways to cool and
heat a home. Heat pumps use a refrigeration instead of fuel combustion to heat and cool, and because heat pumps
can extract warm air to heat your home from temperatures as low as 30 degrees (f). Heat pumps work on the
principle that heat exists even when temperatures are cool. Most heat pumps are split systems (one coil inside and
one coil outside). When the heat pump is functioning as a heater, the air outside the home is used to evaporate a
refrigerant in the outdoor coil. In this process, heat from the outside air is extracted as it evaporates the liquid
refrigerant in the coil, converting the liquid refrigerant into a warm gas. The gas is then compressed and is
1107 Prince St 2024030703
Make & Model#, Location and Type (continued) Satisfactory
03/07/2024 Hawkeyehome.com 27 of 33
transferred from the outside coil to the indoor coil. Once indoors, the gas is condensed which releases heat in the
process, and the heat is distributed through the house using fans built into the air handler through duct work.
Outside units have a normal life of 6-10 years. Heat pumps should be serviced at least once a year. Adequate airflow
is more critical than with other forced air systems; the filter should be kept clean. It is not advisable to shut off
supply grills to rooms except as required to balance heat and cooling. Units older than 10 years should be evaluated
by a licensed HVAC company. A home inspector is not allowed by standards of practice to run diagnostics on any
equipment.
Approximate Size and Age Satisfactory
The approximate size is given in "Tons". A ton is approximately 12000 BTU's per hour. Each ton of BTU can cover on
an average of 600 to 800 square foot. The inspection does not cover areas that require the removal of panels.
According to the states standards of practice "No disassembly of equipment or activating of equipment is allowed".
The cooling system is not tested unless the outside air temperature has been above 65 degree's for the past 24
hours. The inspector may not test the cooling system if the heating system is already in the "on" position at the time
of inspection. Switching between the heat and cooling cycle in a short period of time can damage the units. The
average life of a HVAC system is 10 to 15 years. Some units close to the coast or in high temperature regions may
have a short life span (8-10 years). It is always recommended to have a licensed HVAC company inspect the system.
The inspector cannot run a diagnostic test and only performs a visual inspection.
Approximate size: Placard not legible Approximate Age: Unknown
Placard not legible:
Unknown:
Life expectancy is typically ten to fifteen years, in moderate climates and eight to ten years in hot climates.
Distribution Deficiency
Type: Ductwork Filter: Disposable
Ductwork:
Air ducts, or HVAC ductwork, or AC ducts, are conduits that supply warm or cool air to heat, ventilate, and cool each
room. Air ducts are connected to the HVAC unit which filters then heats or cools your home's air before sending it
off.
Disposable:
Disposable Air filters should be replaced once every 30-60 days to provide proper air circulation throughout the
house. Also do not block furniture in front of returns. If you have only one return location in the home. Closing of
bedroom doors does not allow the air to circulate in those rooms.
Minor Repair
HVAC ducts have come apart or been partially removed in the attic. Recommend a licensed HVAC company further
evaluate and determine if repair or replacement is needed.
1107 Prince St 2024030703
Make & Model#, Location and Type (continued) Satisfactory
03/07/2024 Hawkeyehome.com 28 of 33
Condition Deficiency
Tested: Not Tested
Safety Concern
Loose conduit found on the electrical disconnect box for the exterior HVAC unit. Exposed electrical wires noted.
General Maintenance
The insulation on the suction line to the condensor (exterior HVAC unit) is deteriorated/not installed. The suction line is
the line that connects the condensor to the airhandler (interior HVAC unit),
Major Concern
HVAC system did not function when tested. The home appears to be heating from the emergency heat strip.
Recommend further evaluation and repair by a HVAC company.
1107 Prince St 2024030703
Distribution (continued) Deficiency
03/07/2024 Hawkeyehome.com 29 of 33
Attic
Location, Access and Inspection Method Satisfactory
Location: Bedroom Access: Scuttle Hole Inspection Method: Walked
Walked:
Interior Roof and Frame Satisfactory
Additional Notes
Water stains found on the interior side of the attic roof sheathing. Moisture readings indicated an inactive leak or dry at
the time of inspection.
Ventilation Deficiency
Types: Gable End Louvers
Gable End Louvers:
A gable vent is typically found on the end of a house, over the garage. A gable is the portion of a house that comes
to a peak. Many homes will have multiple gables and some have multiple gable vents.
General Maintenance
Bathroom exhaust was not duct to exterior wall area in the attic. This could allow moisture to build up in the attic.
Insulation Satisfactory
Type: Cellulose/Fiberglass Average Depth: 10-16 Inches Approximate R-Value: R-30
Cellulose/Fiberglass:
R-30:
Foundation
Foundation type Satisfactory
1107 Prince St 2024030703
Condition (continued) Deficiency
03/07/2024 Hawkeyehome.com 30 of 33
Type: Crawlspace Floor: Dirt
Crawlspace:
According to the states standards of practice the under-floor crawlspace will not be entered if the area is less than
24 inches of vertical clearance between components and the ground or have an access opening smaller than 16
inches by 24 inches. Area will be considered not accessible.
The inspection of the crawlspace is of the area's that are exposed or accessible only. The inspector will not remove
insulation, stored items, or debris. The inspection of the crawlspace is for visible damage to the visible material and
structural components. Any damage covered by the insulation is considered covered and concealed.££
Foundation support and information Deficiency
Foundation Walls and Vents:
Cement block, Brick
Foundation Support: Brick piers Foundation Insulation: None
General Maintenance
Missing or damaged foundation vents noted in several locations on the home. This could allow pest (rodents and
insects) access to the crawlspace.
Crawlspace Deficiency
A crawl space is essentially a hollow area under the floors of some homes between the ground and the first floor. It's
usually roughly 1 foot to 3 feet high—just high enough for someone to enter by crawling, as its name implies (low
ceilings!).
Entrance: Back of Home Accessibility: Readily Accessible Inspection Method: Crawled
Minor Repair
Water stains noted under the back right corner of the home. Moisture readings show an active leak. Recommend
further evaluation and repair by a licensed plumber.
1107 Prince St 2024030703
Foundation type (continued) Satisfactory
03/07/2024 Hawkeyehome.com 31 of 33
General Maintenance
Excessive opening in the sub floor under the bathrooms. This could allow pest or rodents access.
Recommendation
Debris or old construction material noted in the crawlspace. Recommend removing to prevent attacting insect or pest.
Additional Information
Water stains noted under the£laundry room£on the sub-floor or framing. Moisture readings show an in-active leak (dry)
at the time of inspection.
1107 Prince St 2024030703
Crawlspace (continued) Deficiency
03/07/2024 Hawkeyehome.com 32 of 33
Additional Information
Water stains noted under the£right side of the home£on the sub-floor or framing. Moisture readings show an in-active
leak (dry) at the time of inspection.
Additional Notes
Multiple visible repairs noted in the crawlspace. This is common in older homes. Inspector does not grade the quaility of
the repair. Recommend consulting present owner on these repairs.
1107 Prince St 2024030703
Crawlspace (continued) Deficiency
03/07/2024 Hawkeyehome.com 33 of 33
+DZN(\H+RPH,QVSHFWLRQV//&
5HDO(VWDWH+RPH,QVSHFWLRQ$JUHHPHQW
6DPV3RLQW5GVXLWH%HDXIRUW6&
(PDLOWROHQQ\#KDZNH\HKRPHFRP
3URSHUW\WREHLQVSHFWHGBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB
&OLHQW
V1DPHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB
3KRQH1XPEHUBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB
0DLOLQJ$GGUHVVBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB
&LW\BBBBBBBBBBBBBBBBBBBBBBBBBBBB6WDWHBBBBBBBBBBBBBBBBBB=LS&RGHBBBBBBBBBBBBBBBBBBBBBBB
(PDLODGGUHVVBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB
5HDOWRUQDPHDQGSKRQHQXPEHUBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB
$WWRUQH\/DZ)LUPBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB$SSUR[LPDWH&ORVLQJ'DWHBBBBBBBBBBBBBBBB
7KLVDJUHHPHQWLVPDGHEHWZHHQDQGHQWHUHGLQWRE\+DZN(\H+RPH,QVSHFWLRQV//&KHUHLQDIWHUUHIHUUHGWRDV
³,QVSHFWRU´DQGWKHDERYHPHQWLRQHGFXVWRPHUVKHUHLQDIWHUUHIHUUHGWRDV³&OLHQW´
,QFRQVLGHUDWLRQRIWKHSURPLVHDQGWHUPVRIWKLVDJUHHPHQW,QVSHFWRUDQG&OLHQWDJUHHDVIROORZV
,QVSHFWRUVKDOOSHUIRUPDKRPHLQVSHFWLRQVHWIRUWKE\WKH 6WDWH
V6WDQGDUGVRI3UDFWLFH RQWKHSURSHUW\DERYHDV
DJUHHG &OLHQW XQGHUVWDQGV WKDW D KRPH LQVSHFWLRQ ³DV VHW E\ WKH VWDWHV VWDQGDUGV RI SUDFWLFH´ DW LVVXH KHUHLQ LV D
YLVXDO REVHUYDWLRQ ZLWK OLPLWHG XVH RI PHFKDQLFDO LQVWUXPHQW DQG RI UHDGLO\ DFFHVVLEOH DUHDV RI WKH EXLOGLQJ
DFFRUGLQJWRWKH6WDWH
V6WDQGDUGVRI3UDFWLFH7KHLQVSHFWLRQ LVLQWHQGHGDVDJHQHUDOJXLGHWRKHOSWKH&OLHQWPDNH
KLVKHUWKHLURZQHYDOXDWLRQRIWKHRYHUDOOFRQGLWLRQRIWKHKR PH7KHLQVSHFWLRQH[SUHVVHVWKHSURIHVVLRQDORSLQLRQ
RI WKH LQVSHFWRU DW WKH WLPH RI LQVSHFWLRQ RQO\ DQG H[SUHVVHV QR ZDUUDQW\ RU JXDUDQWHH DJDLQVW GHIHFWV LQ WKH
VWUXFWXUH,QVSHFWRUGRHVQRWJUDGHTXDOLW\RIFRQVWUXFWLRQRU UHSRUWDOOQRUPDOZHDUDQGWHDULVVXHV0DMRU0LQRU
DQG 6DIHW\ FRQFHUQV VKRXOG EH IXUWKHU HYDOXDWHG E\ D OLFHQVHG SURIHVVLRQDO VWUXFWXUDO HQJLQHHU DQGRU D OLFHQVHG
UHVLGHQWLDOEXLOGHU
&OLHQWXQGHUVWDQGVWKDWWKLVLV127DQ(QJLQHHU
VLQVSHFWLRQUHSRUWQRUDQ(QYLURQPHQWDO+D]DUGRXV WR+HDOWKRU
6DIHW\LQVSHFWLRQUHSRUW7KHUHSRUWWKDWZLOOEHSUHSDUHGE\W KH,QVSHFWRULV 127DFRPSOLDQFHFRGHLQVSHFWLRQRU
FHUWLILFDWLRQ LQVSHFWLRQ RU FHUWLILFDWLRQ IRU SDVW RU SUHVHQW JRYHUQPHQW FRGHV RU UHJXODWLRQV RI DQ\ NLQG 7KLV
LQVSHFWLRQLVQRWLQWHQGHGWREHWHFKQLFDOO\H[KDXVWLYH7KLVL QVSHFWLRQGRHVQRWLQDQ\ZD\UHSUHVHQWDFRPPHUFLDO
LQVSHFWLRQ RU DQ LQVSHFWLRQ WR TXDOLI\ IRU FRPPHUFLDO SXUSRVHV 7KH ,QVSHFWRU GRHV QRW WHVW UHSRUW RU LQVSHFW IRU
W\SHV RI PROG PLOGHZ DQGRU PRLVWXUH RQ SURSHUWLHV ZLWK VWXFFR H[WHULRUV LW LV UHFRPPHQG WR KDYH D PRLVWXUH
WHVW 7KLV LQVSHFWLRQ GRHV QRW LQFOXGH RXWEXLOGLQJV RU VKHGV 7KLV LQVSHFWLRQ GRHV QRW LQFOXGH VLWH HQKDQFHPHQWV
SRROV ORZ YROWDJH OLJKWLQJ DQG LUULJDWLRQ V\VWHPV $ PRUH FRPSUHKHQ VLYH LQVSHFWLRQ PD\ EH DYDLODEOH E\
HQJLQHHULQJILUPVRURWKHUFRPSDQLHV7KLVLQVSHFWLRQLVLQWHQGHGWRILQGYLVLEOHGDPDJHWRWKHSURSHUW\
3DJHRI
,QWBBBBBBBBBBBBSEP
SEP
1107 Prince Street Beaufort, SC
Suzanne Previte
4124805568
1206 Oakridge Road
McDonald PA 15057
previte64@gmail.com
n/a
n/a n/a
/,0,7$7,212)/,$%,/,7<
$VKHOGE\WKH6XSUHPH&RXUWRI6RXWK&DUROLQDLQ *ODGGHQY%R\NLQ6& ,WLVXQGHUVWRRG
DQGDJUHHGWKDWVKRXOG,QVSHFWRUEHIRXQGOLDEOHIRUDQ\ORVVR UGDPDJHVUHVXOWLQJIURPDIDLOXUHWRSHUIRUPDQ\RI
LWVREOLJDWLRQVSXUVXDQWWRDQ\DVSHFWRIWKHLQVSHFWLRQRUWKL VDJUHHPHQWLQFOXGLQJEXWQRWOLPLWHGWRQHJOLJHQFH
EUHDFKRIFRQWUDFWRURWKHUZLVHWKHOLDELOLW\RIWKH,QVSHFWR UDQGRUDJHQWVRUHPSOR\HHVVKDOOEHOLPLWHGWRDVXP
HTXDOWRWKHDPRXQWRIWKHIHHSDLGE\WKH&OLHQWIRUWKLVLQVSHFWLRQDQGUHSRUW
& OLH QWDJU HHVDQGD FNQ RZOH GJHVWKD WWKHP HQ WLR QHGVXPLVWKHVROHDQGH[ FO XVLYHU HPH G\RIW KH& OLHQ W& OL HQW
IXUWKHUDJUHHVWRSD\DOOOHJDOH[SHQVHVDWWRUQH\
VIHHVDQGUHDVRQDEOHFRPSHQVDWLRQIRUWKHORVVRIWLPHWKDWPD\EH
LQFXUUHGE\,QVSHFWRUDVDUHVXOWRIDQ\OHJDODFWLRQE\WKH&OLHQWZKHUHWKH&OLHQWVHHNVWRUHFRYHUDQ\DPRXQWPRUH
WKDQWKHVXPHTXDOWRWKHDPRXQWRIWKHIHHVSDLGE\WKH&OLHQWIRUWKLVLQVSHFWLRQDQGUHSRUW
7KLUG3DUW\,QGHPQLILFDWLRQ 7KLVLQVSHFWLRQDQGUHSRUWLVQRWLQWHQGHGIRUWKHXVHRUEHQ HILWRIDQ\RQHRWKHU
WKDQWKH&OLHQWOLVWHGDERYHDQG&OLHQWDJUHHVWKDWKHVKHZLOOQRWSURYLGHWKHLQVSHFWLRQUHSRUWRUDQ\UHVXOWVRIWKH
LQVSHFWLRQ WR DQ\ SDUW\ 1R WKLUGSDUW\ VKDOO KDYH DQ\ ULJKW DULVLQJ IURP WKH LQVSHFWLRQ RU WKLV UHSRUW ,Q
FRQVLGHUDWLRQIRUWKH,QVSHFWLRQ&RPSDQ\ IXUQLVKLQJ WKH UHSRUW &OLHQW VKDOOLQGHPQLI\ DQG KROG WKH,QVSHFWLRQ
&RPSDQ\DQGLQVSHFWRUVKDUPOHVVIRUDQ\FODLPVGHPDQGVRUFRVWVDVDUHVXOWRIDQ\WKLUGSDUW\GHPDQGRUFODLP
DULVLQJRXWRIWKHLQVSHFWLRQRUWKHUHSRUW
',6&29(5<2)352%/(067KH&OLHQWDJUHHVWRQRWLI\,QVSHFWLRQ&RPSDQ\LQZULWLQJRI DQ\FRPSODLQWVRU
LWHPVLQTXHVWLRQZLWKLQIRXUWHHQGD\VRIGLVFRYHU\DQGWR DOORZWKH,QVSHFWLRQ&RPSDQ\DQGWKH,QVSHFWRU
DFFHVVWRWKHSURSHUW\WRHYDOXDWHWKHVHLWHPVEHIRUHFRUUHFWLYHDFWLRQLVWDNHQ,PPHGLDWHUHSDLUVKRXOGEHPDGHLQ
OLIHWKUHDWHQLQJVLWXDWLRQV,QRWKHUWKDQOLIHWKUHDWHQLQJVLW XDWLRQV&OLHQWIDLOXUHWRSHUPLWWKH,QVSHFWLRQ&RPSDQ\
WRUHLQVSHFWWKHLWHPVLQLVVXHVKDOOPHDQWKH&OLHQWKDVZDLYH GDQ\FODLPDJDLQVWWKH,QVSHFWLRQ&RPSDQ\DQG
LQVSHFWRUVZLWK UHVSHFWWR WKDW LWHP,I RULJLQDO FRQGLWLRQ VWUXFWXUH FRPSRQHQW XQLW RU HOHPHQW KDVFKDQJHG
UHPRYHGZRUNHGRQHWFHWHUDIURPWKHRULJLQDOGDWHWLPHRILQV SHFWLRQWKDWFKDQJHVWKH,QVSHFWRU¶VRULJLQDOYLVXDO
LQVSHFWLRQYLHZYRLGVDQ\FODLPVPDGHLQWKDWVSHFLILFDUHDORFDWLRQFRPSRQHQWXQLWRUVWUXFWXUH,QQRHYHQWVKDOO
DQ\DFWLRQEHEURXJKWDJDLQVWWKH,QVSHFWLRQ&RPSDQ\RU,QVSHFW RUVIRUDEUHDFKRIWKLV$JUHHPHQWDWDQ\WLPH
EH\RQGVL[PRQWKVDIWHUWKHGDWHRIWKHLQVSHFWLRQDQGWKLV$JUHHPHQW
&OLHQWDJUHHVIRUWKH,QVSHFWRUWRUHOHDVHWKHLQVSHFWLRQUHSRU WDQGDQ\DQGDOOELOOLQJDFWLYLW\DVVRFLDWHGZLWKWKH
LQVSHFWLRQ WR DQ\ UHDO HVWDWH DJHQF\ DQG RU DWWRUQH\ WKDW LV SDUWLFLSDWLQJ LQ WKH SXUFKDVHVDOH RI WKH LQVSHFWHG
SURSHUW\
&OLHQWXQGHUVWDQGVWKH )HHVDUHQRWFRQWLQJHQWRQWKHILQDOVDOHRIWKHKRPH ,QWKHHYHQWWKHKRPH
GRHVQRWFORVHDQGRUSD\PHQWLV PLVVHGDWFORVLQJ WKDWWKH &OLHQWLVUHVSRQVLEOHIRUDOOIHHVGXHDQGSD\PHQW
ZLOOEHPDGHIXOOZLWKLQWKLUW\GD\V ,ISD\PHQWLVQRWUHFHLYHGZLWKLQWKLUW\GD\VRIWKHLQVS HFWLRQRU
FORVLQJGDWHDODWHIHHRI SHUPRQWKZLOOEHDVVHVVHG IRUHDFKPRQWKSHULRGDIWHUWKHGDWHRIWKHRULJLQDO
FORVLQJDQGRUWKHGDWHWKHLQVSHFWLRQUHSRUWZDVSURYLGHGWRWKH&OLHQW
%\VLJQLQJEHORZWKHSDUWLHVDFNQRZOHGJHWKDWWKH\KDYHKDGWK HRSSRUWXQLW\WRUHDGERWKSDJHVRIWKLVFRQWUDFW
WKDW&OLHQWZLOOUHDGWKHUHSRUWDQGDOOGLVFODLPHUVDWWDFKHGZLWKWKHUHSRUWEHIRUHSXUFKDVLQJWKHSURSHUW\WKDW&OLHQW
XQGHUVWDQGVWKHWHUPVDQGFRQGLWLRQVKHUHLQDQGWKDW&OLHQWDJUHHVWREHERXQGE\WKHVHWHUPVDQGFRQGLWLRQVDQGWR
SD\WKHLQVSHFWLRQIHH
,WLVWKHFOLHQWVUHVSRQVLELOLW\WRPDNHVXUHDFRS\RIWKHLQYRLFHLVVXEPLWWHGWRWKHDWWRUQH\LISD\LQJWKURXJK
FORVLQJ
$FFHSWDQFHDQGXQGHUVWDQGLQJRIWKLVDJUHHPHQWDUHKHUHE\DFNQRZOHGJHG
&OLHQW6LJQDWXUHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB
'DWHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB
3DJHRI
Suzanne E Previte (Mar 1, 2024 11:55 EST)
Suzanne E Previte
Mar 1, 2024
!" #$%&"#
' "()$%")*
+
,
- !.#!!./"01234##5,6&!.7-,
9
9#
"
-
:"#$%&"#
' "()$%")*
+
;5;,
-
<
4(*
0
=;5;,
&<$:"<
4(*
=;5;,
<
4(*
> &<
==;5;,
-
:"> &<
'<
4(*
+
-
==;5;,,
<
*
==;5;,
CITY OF BEAUFORT
HTRC – Pre-Design Application Meeting
1911 BOUNDARY STREET
BEAUFORT, SOUTH CAROLINA 29902
(843) 525-7011 FAX: (843) 986-5606
Meeting Summary
Date: 9/11/2024
Project Address: 1107 Prince St
Project Narrative: Proposed renovations, additions, & future ADU
Applicant: Benjie Morillo with Frederick + Frederick Architects
Synopsis of staff comments:
• Planning and zoning:
o Need to obtain a curb cut from SCDOT
o ADU design approval ideally to be submitted with the property
• Transportation:
• Fire:
• Building Codes:
o All setbacks seem to be met
o Flood zone X
• Architecture:
o Zoned T4-N
o Non-contributing, circa 1960
o Provide the pervious and impervious coverage information
o Staff supports proposed changes and additions
o Pay attention to Beaufort Code Section 4.7 for seven integrities for infill.
o Staff supports proposal to raise roof by 2 but concerned with how this impacts the
scale of the portion that faces the street. Could the roof pitch be steeper with plate
height minimally changing?
o Staff does not support the use of the transom window as they are not typical of
Beaufort Historic District. Staff supports window sizes being slightly larger than
typical to create a differentiated yet compatible aesthetic. Possibly keep windows
similar in scale on the front elevation and switch to larger windows down the
sides and rear.
o Since the existing windows are 6/6, can a different configuration other than 1/1 be
used? Maybe 2/2?
o Consider the cladding material as it wraps the building. There may be moments
where the cladding changes at intersections of old and new.
o Recommend adding simple cap and base to all columns
• HBF:
o 1960’s building, still in shape and form to the district and neighborhood
o Agree with staff architects on not having transom over the windows
o Suggest trying to stick to the original form of the 1960’s design
o Important to differentiate the original form from the additions
o 2/2 windows are preferred by HBF on the existing structure
Applicant’s Next Steps: Submit by last Friday of October. Need final submittals and any
revisions.
Be advised that this letter is given as a courtesy to applicants and may not contain all project guidelines.
For a complete history of the meeting, please request the audio recording. Please refer to the Beaufort
Code for applicable sections. If there are any changes to the project, not discussed in this meeting, you
will need to return to a HTRC – Pre-Design meeting.
If you have any questions, feel free to call the Community Development Department at (843) 525-7014.
Thank you for your patience and cooperation during the review process.
Sincerely,
City of Beaufort Community Development
STAFF REPORT: Historic District Review Board (HRB)
1107 PRINCE STREET
DATE: May 14, 2025
GENERAL INFORMATION
Applicant: Benjie Morillo (Architect)
Site Address / Tax PIN: 1107 Prince Street; R120 004 000 0503 0000
Applicant's Request: Applicant is requesting final approval to partially demolish the existing
structure, enclose the existing screen porch, extend the main house
footprint at the front towards Prince Street, and add a new screened
porch and terrace.
Current Zoning: T4-NEIGHBORHOOD DISTRICT (T4-N)
Contributing/Neighborhood Noncontributing – Northwest Quadrant (ca. 1960)
Flood Zone/Base Flood Flood Zone X, Elevation: 17’-18’
Existing Trees No Specimen/Landmark trees are affected by this request.
ZONING DISTRICT INFORMATION
T4-HISTORIC NEIGHBORHOOD DISTRICT (T4-HN)
Lot Width at Setback: N/A
Minimum Lot Size: N/A
Max Lot Coverage: 70% of lot area (This percentage indicates maximum lot coverage by roofs;
total impervious coverage may be an additional 10%. Parcels may also be
subject to Section 8.3 - Stormwater)
Min. Frontage Build Out 60% min; 85% max
Front Setback 0 ft -15 ft
Side Setback Corner: 0 ft – 10 ft; Interior: 5 ft min., 0 ft if attached
Rear Setback 10 ft min; from alley: 0 ft.
Building Height: Primary: 4 stories max; 3.5 stories max in & fronting Historic District &
interior lots along Allison Rd
Accessory: 2 stories / 30 ft max
SURROUNDING ZONING, LAND USE AND REQUIRED BUFFERS
Adjacent Zoning Adjacent Land Uses Setbacks for Adjacent Zoning
/Buffer required if rezoned
North: T4-HN 1106 Duke St (SFH, contributing,
ca. 1920)
1108 Duke St (SFH,
noncontributing, ca. 1945)
N/A
South: T1 St. Helena’s Anglican Church &
Cemetery (600 Newcastle St) N/A
East: T4-N Grand Army of the Republic Hall
(706 Newcastle St, ca. 1896) N/A
West: T4-N House of God Church (1109 Prince
St., noncontributing, ca. 1900) N/A
2
Background: The applicant is proposing major changes and a partial demolition to 1107 Prince Street. The
existing house is a 1-story frame dwelling, ca. 1960, sitting on a 10,055 sqft lot (0.231 acres). The changes include
enclosing the existing screen porch, extending the main house footprint at the front, a new screened porch, and a
new terrace. Applicant has been to one (1) HTRC Meeting on September 11th, 2024, and received overall
positive comments in support of the project.
Tree Removal Proposed:
No Specimen/Landmark trees are affected. A single 10-inch laurel oak is proposed to be removed as it lies within
the footprint of the driveway. Laurel Oaks are never considered specimen or landmark trees, regardless of size.
Roughly 15 other trees are proposed to be preserved and remain on site.
Surrounding Area:
This property lies within the Northwest Quadrant neighborhood of the Historic District. While this property itself
is classified as noncontributing, many of the surrounding properties are classified as contributing structures. With
the cemetery immediately to the south, and the multitude of churches all within a single block, this immediate area
of Prince Street is of no doubt significant importance to the district.
Determination of adequate historic integrity for New Construction, Infill, Additions and Demolition:
As per the Beaufort Preservation Manual (Chapter 5) and the Beaufort Development Code (Section 4.7), the
compatibility of new infill construction as well as major renovations within Beaufort Historic District is determined
in consideration with the following principles: 1. Location, 2. Design, 3. Setting, 4. Materials, 5. Workmanship,
6. Feeling and 7. Association. See detailed staff analysis and recommendations in table below.
4.7.2 Integrity Guidelines (as per Beaufort
Development Code)
Rationale
Present
Staff Analysis of Rationale
1. Location: This is the relationship between the
property and its historical context.
YES 1107 Prince Street is in an area of the
Northwest Quadrant that features many
cemeteries and churches. The proposed
renovations respect the sensitive historic
context of the area, and do not detract or
pull influence or attention away from the
more prominent structures and sites in the
immediate area.
3
2. Design: This is the combination of elements
that create the feeling of a district or structure.
These elements include building patterns,
streetscapes, site elements, building size, mass
and scale, spatial relationships, and specific
architectural elements and details.
YES The proposed design of the renovation
maintains the overall feeling of the
Northwest Quadrant. The newly renovated
house will not alter the streetscape, nearby
site elements, or the spatial relationship
with nearby buildings.
3. Setting: This is the physical environment of a
property and should be evaluated on its context
as well as on the historical role the property has
played and continues to play. Important features
include topography, vegetation, man-made
features, and relationships between existing
structures and their surroundings.
YES The relationship between the house and the
historic setting of the neighborhood are well
respected by the proposed design, materials
and dimensions.
4. Materials: These are the physical elements
that make up a property or district.
YES The proposed materials are all acceptable
within the Historic District for a
noncontributing structure.
5. Workmanship: This is the physical evidence
of the crafts of a particular culture or time
period. This particularly applies to rehabilitation
projects, but for new infill projects, workmanship
of surrounding structures should be considered
and respected.
YES The proposed renovation respects the
workmanship of the existing house as well
as the surrounding structures.
6. Feeling: This is the property's expression of
the aesthetic or historic sense of a particular
period of time. This particularly applies to
rehabilitation projects, but for new infill projects,
the feeling of surrounding structures should be
considered and respected.
YES The proposed aesthetics respect the feeling
of surrounding structures, and promotes the
feeling in regard to historic sense,
composition and architecture.
7. Association: This is the direct link between an
important historic event or person and a
property.
YES The proposed renovation is in keeping of the
architectural integrity and preservation
standards and thus respects the historic
importance the house has to the Beaufort
Historic District.
4
FINDINGS AND RECOMMENDATIONS
Staff Recommendation: Staff recommends Final Approval for the proposed renovation + partial
demolition, in that it satisfies the intent of the Beaufort Preservation Manual and requirements of the
Beaufort Code, with the following recommendations:
1. Applicant to note that all windows and doors must have external grilles with internal spacer bars.
2. Staff recommends the applicant add one or two windows on the west façade at Bedroom 1 to
break up the continuous stretch of blank wall. Staff would be supportive of either of the window
sizes already shown on the west façade.
Source: City of Beaufort website. First collected Nov 8, 2026.