Design Review Board (DRB) — Agenda Packet
City of Spartanburg · Spartanburg County · Boards and Commissions · meeting of Jan 2, 2024 · Agenda packets
Open the original document More from City of Spartanburg
Text
Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.
The City of Spartanburg
Design Review Board
City of Spartanburg | Design Review Board Agenda 1
AGENDA
January 2, 2024, at 6:00 P.M.
Spartanburg County Council Chambers
366 N. Church Street – Spartanburg, SC 29303
(
Please Note: Items as they appear on the Docket may or may not be considered in the order as they are
presented. The Chairman will announce any changes after the roll call).
I. Call to Order.
II. Roll Call.
III. F
reedom of Information Act Compliance – Public notification of the Design Review Board meeting
ha
s been published, posted and mailed in compliance with the Freedom of Information Act and the
requirements of the City of Spartanburg Zoning Ordinance
IV. Approval of Agenda.
V. D
isposition of the Minutes of December 5, 2023, meeting.
VI. Old Business: None.
VII. New Business:
DRB-23-020-00009 – The Design Review Board (DRB) has received a request for Preliminary
conceptual approval of the buildings form, massing, and placement on the site for the Oakland
Avenue Townhomes Development located at 214 and 218 Oakland Avenue (Tax Map Sheet: 7-
12-07-118.00 and 7-12-07-117.00). Owner/Applicant: Roy Smalls / Agent: Zedekiah
H
eydenburg, Site Design Inc.
V
III. Staff Announcements:
I
X. Adjournment.
For more information, please call Martin L. Livingston, Jr., AICP, CPM, Community Development Director at
(864) 58
0-5323 or by email at planning@cityofspartanburg.org.
Page 1 of 37
DRB – Meeting Minutes – 2023-12-05
Page 1 of 6
Meeting Minutes of the Design Review Board (DRB)
Tuesday, December 5, 2023, at 5:30 PM
City Council Chambers
The Design Review Board (DRB) on Tuesday, December 5, 2023, at 5:30pm. The following
Board Members were in attendance: Lauren Rogers, Tori Wallace-Babcock, Lucy Lynch,
Alexander Newman, and Lukas Hauser. Representing the City of Spartanburg’s Planning
Department was Martin Livingston, Community Development Director; Nan Zhou, Planner
II; and Tia Keitt, Planner II.
Roll Call:
Ms. Rogers: Lauren Rogers
Ms. Babcock: Tori Wallace-Babcock
Mr. Newman: Alexander Newman
Ms. Lynch: Lucy Lynch
Mr. Hauser: Lukas Hauser
Ms. Lynch: Per the Freedom of Information Act, public notice of this meeting has been
published, posted and mailed in compliance with the Freedom of Information Act and the
requirements of the City of Spartanburg Zoning Ordinance. We have one item on the agenda for
new business and no old business.
Approval of Agenda
On a motion by Ms. Rogers and second by Mr. Newman, the agenda was approved by a
vote of 5 to 0.
Ms. Rogers: Motion to approve.
Mr. Newman: Second
Ms. Lynch: All in favor of approving the amended agenda say aye?
Attendees: Aye.
Ms. Lynch: Okay so the amended agenda is approved. Minutes from October 3rd meeting?
Approval of Meeting Minutes for November 7, 2023
On a motion by Ms. Rogers and second by Mr. Hauser, the minutes was approved by a
vote of 5 to 0.
Ms. Rogers: Motion to approve minutes from November 7, meeting.
Ms. Rogers: Second
Ms. Lynch: All in favor of approving the minutes of the November meeting?
Attendees: Aye.
Old Business: None.
Page 2 of 37
DRB – Meeting Minutes – 2023-12-05
Page 2 of 6
New Business:
DRB-23-020-00008 – The Design Review Board (DRB) has received a request for Full and
Final Approval for the proposed Spartanburg County Public Library – Headquarters
Expansion and Planetarium located in the DT Zone (Civic District) at 151 S. Church Street
(Tax Map Sheet: 7-12-21-074.00). Owner: Spartanburg County Library / Applicant: Adam
Flynn and Sarah Stevens, McMillan Pazdan Smith.
GENERAL PROJECT OVERVIEW
The proposed civic building expansion project is on a 4.99 acre parcel at the corner of Broad
Street and South Church Street.
AUTHORITY
This project is zoned Civic. Formal design review and approval by the Design Review Board is
required.
Because of the unique characteristics of the Civic/Landmark Building, it shall be subject to
Design Review in accordance with Section 2.4. As part of this review process, the applicant may
request modifications from the applicable district standards. However, all such modifications
shall otherwise conform to the general principles for Civic/Landmark buildings below:
• If indicated on the Downtown Master Plan, they must comply with the recommendations
therein.
• They should be sited to terminate a street vista whenever possible and must incorporate
appropriate prominent features, designs, and entrances to celebrate a visual termination.
• They should incorporate detailing and materials that are authentic to the intended style.
• A pedestrian plaza, courtyard, or similar landscaped area may be substituted for a
required building frontage and minimum setback line.
• Building entrances for civic buildings may be raised above the street elevation and
accessed via a monumental stair.
• They should respect the character of the fronting streets through the provision of a
pedestrian-friendly orientation including clear entrances from the street and permeable
street walls with adequate windows (no blank walls).
Preliminary Review was issued on August 1, 2023 with the following conditions:
• Resolution of the streetscape along Broad Street
• Presentation of design suggestions to mitigate the blank wall condition along Broad
Street
DETERMINATION OF COMPLETENESS
• Application complete
EXCEPTIONS
• 3.3.2.a Front Building Setback – Maximum setback of 6 ft – Setbacks range from 7 ft 9 in
to 35 ft
o Approval Granted Previously
Page 3 of 37
DRB – Meeting Minutes – 2023-12-05
Page 3 of 6
• 6.4.4.a Minimize Blank Walls – Expanses of blank walls may not exceed 20 feet in
length – Proposed blank wall along Broad Street is 28 ft
o Conditional Approval Granted Previously Subject to Design Alternatives – See
Commentary
• 6.4.4.c Transparency Zone – Glazing (transparent windows or doors) must extend at least
60% of the total façade width – Proposed glazing along Broad Street is less than 60%
(primarily due to the 28 ft blank wall)
o Approval Previously Granted
• 8.1 Streetscape – Minimum 12 ft zone with trees in wells / preferred 16 ft zone
o Modification Requested
CODE REVIEW
A. Use Standards: The proposed use is permitted by right.
B. District Standards:
• 3.3.1 Lot Configuration: Compliant
• 3.3.2 Primary Building Standards: Maximum setback of 6 ft is proposed to be
exceeded
• 3.3.4 Building Height: Compliant
• 3.3.5 Permitted Parking Location: Not applicable
• 3.3.6 Building Frontage: Shopfront - permitted
C. General Standards:
o 4.1 Civic/Landmark Buildings:
• If indicated on the Downtown Master Plan, they must comply with the
recommendations therein. – Compliant
• They should be sited to terminate a street vista whenever possible and must
incorporate appropriate prominent features, designs, and entrances to celebrate
a visual termination. – Compliant
• They should incorporate detailing and materials that are authentic to the
intended style. – Compliant
• A pedestrian plaza, courtyard, or similar landscaped area may be substituted
for a required building frontage and minimum setback line. – Compliant
• Building entrances for civic buildings may be raised above the street elevation
and accessed via a monumental stair. – Compliant
• They should respect the character of the fronting streets through the provision
of a pedestrian-friendly orientation including clear entrances from the street
and permeable street walls with adequate windows (no blank walls). –
Conditional Exception Granted
D. Lot/Site Standards:
o 5.1.1 Lot Frontage: All lots must front on a street, square, or common open
space. Compliant
Page 4 of 37
DRB – Meeting Minutes – 2023-12-05
Page 4 of 6
o 5.1.2 Corner Lots: Buildings located at street intersections must place the main
building, or part of the building, at the corner. Compliant
o 5.1.3 Pedestrian Entries from Frontage Line: Buildings must have their
principal pedestrian entrances on a frontage line. Compliant
E. Utilities and Trash Containment:
• 5.2.1 Underground Utilities: Compliance presumed
• 5.2.2 Solid Waste Storage Areas: Compliance presumed
• 5.2.3 Mechanical and Utility Equipment: Compliant
F. Building Standards:
• 6.1.1 General Design Principles - Connectivity: Exception Conditionally
Granted
• 6.1.1 General Design Principles - Downtown Should be Urban: Compliant
• 6.1.5 General Design Principles - Put People First: Streetscapes should be
composed of wide sidewalks for walking, seating, public art, and landscaping.
Exception required - see additional comments
• 6.2 Required Building Design Standards:
o 6.2.1 Architectural Style: Compliant
o 6.2.2 Compatibility: Compliant
o 6.2.3 Proportions: Compliant
o 6.2.4 Wall Materials: Compliant
o 6.2.5 Façade Treatment: Compliant
o 6.2.6 Building Entrances: Compliant
• 6.4 Specific Building Design Standards for Mixed-Use and Commercial
Buildings in D-T5
o 6.4.1 Roof and Eaves: Compliant
o 6.4.2 Canopies/Awnings: Compliant
o 6.4.3 Encroachments: Compliant
o 6.4.4 Ground Level Detailing
▪ a. Minimize Blank Walls: Expanses of blank walls may not
exceed 20 feet in length. (A “blank wall” is a facade that does not
contain transparent windows or doors.) - Exception required - see
additional comments
▪ c. Transparency Zone: Glazing must extend from the corner of
the front facade for a depth equal to 60% of the length of the
building Exception granted
o 6.4.5 Materials: Compliant
Page 5 of 37
DRB – Meeting Minutes – 2023-12-05
Page 5 of 6
G. Parking:
• Not Applicable
H. Streetscape and Site Landscaping:
• 8.1 Required Streetscape: 16 ft streetscape zone with a minimum 16 ft sidewalk
and trees planted in wells consistent with downtown standards (40 ft on-center).
Exception required - see additional comments
I. Signage: Not applicable.
ADDITIONAL COMMENTS AND SUGGESTIONS FOR BOARD CONSIDERATION
• Blank Wall Condition along Broad Street: The proposed 25-foot-wide blank wall
along Broad Street contains a stairwell for emergency egress. At their previous meeting,
the DRB expressed concern for the proposed condition and requested that the design
team consider a treatment to mitigate this condition that could consider the following
treatments, or others as appropriate:
o Windows in the stairwell (presumably fire-rated) – an irregular pattern combined
with LED backlighting could make for a very interesting public art element
o Signage structure on which banners advertising library or community events can
be hung
o A vegetative element such as a green screen (vines trained to grow up the wall) or
some foundation plantings
o A public art component (e.g., applied sculpture, lighting, mural, video wall)
The proposed treatment appears to depict a modular brick pattern that breaks the
smoothness of the wall but still utilizes the same brick type and color. We have been told
by the applicant that lighting would also be included but as of this writing were awaiting
the details. In our view, this is a bit too subtle a treatment, at least what we’ve seen thus
far, relative to other blank wall conditions that have been approved by the DRB.
We recommend that the DRB provide further guidance to the applicant and request that
they come back at a later date to review the final design proposal.
• Substandard Streetscape along Broad Street and Church Street: The Broad Street
area is rapidly changing and there is a need to improve the streetscape conditions to
accommodate the future activities along that corridor. The DT-6 calls for a 16-foot-wide
streetscape zone and a 12-foot-wide streetscape zone in DT-5, consistent with the other
frontages along Broad Street. Given how many people we expect to be walking along
Broad Street, specifically to approach the Library expansion, we do believe that the
ideally configuration warrants the DT-6 standard streetscape, However, we do recognize
the existing conditions and believe that the 12 foot streetscape section is the bare
minimum condition with a goal of trying to retrofit as close to the 16 foot-wide
streetscape as possible.
The proposed streetscape condition remains substandard and actually takes a step
backward by removing some of the existing trees that provide a buffer between the
Page 6 of 37
DRB – Meeting Minutes – 2023-12-05
Page 6 of 6
sidewalk and the roadway. In addition, the proposed hardscape seems to duplicate
pathways and inserts retaining walls in the streetscape that unnecessarily segments the
overall dimension to create two substandard pathways.
We recommend that this area be reconsidered to consolidate the public sidewalk and
private ramp area along Broad Street. Because this is a public infrastructure partnership
with the City, we recommend the DRB defer finalization of this requirement to the City
staff to achieve a minimum of a consistent 12 foot streetscape. If an exception is still
required, staff would bring it back to the DRB.
RECOMMENDATION
We recommend final approval of the building and Church Street site elements conditioned on a
future approval by the DRB of the final proposed treatment of the Broad Street blank wall
condition. We further recommend that approval of the Broad Street site elements be deferred to
the staff for final resolution.
Applicant:
Todd Stevens, Spartanburg County Public Library
Adam Flynn, McMillan Pazdan Smith
Sarah Stevens, McMillan Pazdan Smith
David McCutcheon, McCutcheon Engineering
Public Comments: None.
Discussion:
The primary concern for the Design Review Board was the blank wall. Several recommendations
were made about lighting for the blank wall which did not appear on the plans and possible other
possible lighting, windows, and banner designs that could be a feature of the wall. The street
landscaping and sidewalk was a tough issue to address. There did not appear to be a lot of
options to address the sidewalk and landscaping on Broad Street.
A motion was made by Ms. Wallace-Babcock, seconded Mr. Newman for Full and Final
Approval with an exception for the sidewalk and landscaping by a vote of 5-0. The blank
wall would return to the DRB for review and approval.
Staff Announcements:
DRB Meeting location beginning January 2024 will be in the Spartanburg County Council
Chambers. The alternative meeting location if there are conflicts with Council Chambers will be
at the Dr. T.K. Gregg Recreation Center.
Adjourn meeting at 6:39 PM
_________________________________
Lucy Lynch, Chairperson
Page 7 of 37
Page 8 of 37
PRELIMINARY REVIEW - REQUIRED DOCUMENTS
Completed Design Review Board (DRB) Application Form
Packaged PDF Documents (All documents to be submitted as a packaged PDF in 11X17 or 18X24 formats with consistent
page sizes and scaled drawings with common increments)
1. Existing Conditions Analysis
a. Context Plan/Map (Identifying Site Context and Zoning District of Proposed Site)
b. Aerial Image of Site/Context (Google Earth, ArcGIS or similar)
c. Comprehensive Site Photos (showing adjacent buildings and area context)
2. Site Plan (Schematic Level)
a. Layout of all structures (showing north arrow, graphic drawing scale, cardinal directions, property lines,
dimensions and adjacent streets labeled)
b. Footprints of adjacent structures (if applicable)
c. Site elements (including sidewalks, paths, and landscape areas)
d. Parking and loading areas
e. Conceptual site grading (indicating any expected retaining walls and stormwater management/site drainage
features)
f. Site Sections (as appropriate, to illustrate unique grade configurations)
3. Elevations and Floor Plans for all buildings (Schematic Level)
a. Proposed Finished Floor Elevation(s)
b. Building Elevations (in color, with proposed material call-outs)
c. Floor Plans
d. Roof Plan
e. Expected locations of mechanical equipment (ground and roof mounted)
f. Material Selections and Colors (image and manufacturer product name/number)
4. Perspective Illustrations (Minimum of 2)
a. Proposed view on project side of street (including adjacent structures, as it would be seen at eye level by a
pedestrian on a sidewalk abutting the property)
b. Proposed view on opposite side of street (including adjacent structures, as it would be seen at eye level by a
pedestrian on a sidewalk across the street from the property)
c. A bird’s eye view of the block bounded by the surrounding streets (as applicable)
d. Additional renderings/views (recommended)
5. Modification of Standards and/or Special Exceptions (if necessary)
a. Description of Requested Modifications/Special Exceptions including a statement of the unique design
considerations that contribute to this request and the proposed design solutions
b. Additional drawings that depict the applicant’s proposed design, configuration, or material modifications
PRELIMINARY REVIEW SCHEDULE:
• Initial Package Submitted to City – 3 weeks prior to DRB meeting
• Review by Design Manager – 2 weeks prior to DRB Meeting
• Final Submission of Preliminary Design Package – 1 week prior to DRB Meeting
• Note: An additional meeting may be necessary for the DRB to consider any requested Modification of Standards or
Special Exceptions.
Page 9 of 37
FULL and FINAL REVIEW - REQUIRED DOCUMENTS
Completed Design Review Board (DRB) Application Form
Packaged PDF Documents (All documents to be submitted as a packaged PDF in 11X17 or 18X24 formats with consistent
page sizes and scaled drawings with common increments)
1. Existing Conditions Analysis
a. Context Plan/Map (Identifying Site Context and Zoning District of Proposed Site)
b. Aerial Image of Site/Context (Google Earth, ArcGIS or similar)
c. Comprehensive Site Photos (showing adjacent buildings and area context)
2. Site Plan (Construction Drawing Level)
a. Layout of all structures (showing north arrow, graphic drawing scale, cardinal directions, property lines,
dimensions and adjacent streets labeled)
b. Footprints of adjacent structures (if applicable)
c. Hardscape elements (including sidewalks, paths, and other paved surfaces)
d. Landscape Plan (showing all required tree preservation, tree planting, screening, and foundation plantings)
e. Site Lighting Plan (with locations and type of all proposed fixtures)
f. Parking and Loading Areas
g. Site Grading (indicating any retaining walls and stormwater management/site drainage features)
h. Site Utilities and Solid Waste Management Plan
i. Preliminary Plat (as appropriate)
3. Elevations and Floor Plans for all buildings (Design Development or Construction Drawing Level)
a. Building Elevations (in color, with proposed material call-outs)
b. Floor Plans
c. Roof Plan
d. Locations of mechanical equipment (ground and roof mounted)
e. Material selections (image and manufacturer product name/number)
f. Building Lighting Plan (with locations and type of all proposed fixtures)
g. Location of Signage
h. Existing Grade and Proposed Grade (with finished floor elevations and building height, measured from the
highest curb elevation adjacent to the site)
i. Wall Sections that depict the various construction systems and materials specific to the proposed area of the
building (i.e., not simply a “typical” wall section)
j. Material Selections and Colors (image and manufacturer product name/number AND material sample/color
board) for all exterior materials, finishes, windows, awnings/canopies, and fixtures
4. Perspective Illustrations (Minimum of 2)
a. Proposed view on project side of street (including adjacent structures, as it would be seen at eye level by a
pedestrian on a sidewalk abutting the property)
b. Proposed view on opposite side of street (including adjacent structures, as it would be seen at eye level by a
pedestrian on a sidewalk across the street from the property)
c. A bird’s eye view of the block bounded by the surrounding streets (as applicable)
d. Additional renderings/views (recommended)
FINAL REVIEW SCHEDULE:
• Initial Package Submitted to City – 3 weeks prior to DRB meeting
• Review by Design Manager – 1 week
Page 10 of 37
Memo
www.arcadis.com
1/4
SUBJECT
DRB-214 Oakland Avenue
TO
Members of the Spartanburg Design Review Board
DATE
12/21/2023
OUR REF
7-12-07-118.00 & 117.00
DEPARTMENT
Community Development
PROJECT NUMBER
10-210098.00
COPIES TO
City Staff
NAME
Craig Lewis, Urban Design Consultant
craig.lewis@arcadis.com
GENERAL PROJECT OVERVIEW
The proposed 10-unit townhome project sits on 0.52 acres across two lots at the corner of Oakland Avenue and
East Saint John Street. The southern parcel along East Saint John is an existing parking lot and is nearly
completely impervious. There is a 20” water oak tree on the 218 Oakland Avenue parcel located in the front
setback area. The proposed units are intended to be for-sale, necessitating a subdivision plat (presumably as a
condominium project) prior to final approval.
AUTHORITY
This project is split zoned with the northern parcel (218 Oakland) zoned D-T4 and the parcel along East Saint
John Street (214 Oakland) zoned D-T5. Without a rezoning to consolidate the zoning across the entire site, each
parcel will have to express compliance individually. Formal design review and approval by the Design Review
Board is required.
DETERMINATION OF COMPLETENESS
• Application complete
EXCEPTIONS
• 3.3.2 Front Yard Setback: The maximum front setback along East Saint John is precluded by an existing
electrical easement
o Approval Recommended
• 5.1.1 Lot Frontage; 5.1.3 Pedestrian Entries from Frontage Line; 5.1.5 Adjacent Lots; 6.2.6 Building
Entrances: Units do not front a street
o Approval Recommended with unit redesign to provide a front door onto an interior court with
pavers
• 5.1.2 Infill Setbacks: The proposed building are not consistent with the surrounding buildings
o Approval Recommended subject to confirmation of the proposed elevation
• 6.3.1 Flat roofs in D-T4
o Approval Recommended
• 6.4.4 Garage Access: Units 3-6 have front loaded garages
o Approval Recommended with unit redesign to provide a front door onto an interior court with
pavers
CODE REVIEW
Page 11 of 37
214 Oakland Avenue
Spartanburg Design Review Board
12/21/23
www.arcadis.com
DRB - 214 Oakland Avenue - DRB Preliminary Review-122123 2/4
Exceptions or deviations required are noted in blue italics
A. Use Standards: The proposed use (dwelling-multi-family) is permitted by right in both districts.
B. District Standards:
• 3.3.1 Lot Configuration: Not applicable
• 3.3.2 Primary Building Standards: Lots 1 & 2 are subject to D-T4 standards and the remaining
are subject to D-T5. – Setbacks are not depicted on the submitted drawings but when scaled,
they appear to be compliant except lots 7-10 exceed the maximum front setback due to an
existing electrical easement
• 3.3.4 Building Height: Compliant
• 3.3.5 Permitted Parking Location: Compliant for Lots 1-2 and 7-10
• 3.3.6 Building Frontage: Stoop - permitted
C. General Standards:
• Not applicable
D. Lot/Site Standards:
• 5.1.1 Lot Frontage: All lots must front on a street, square, or common open space. - Lots 3-6
front the interior court/alley
• 5.1.3 Pedestrian Entries from Frontage Line: Buildings must have their principal pedestrian
entrances on a frontage line. Non-compliant for Lots 3-6
• 5.1.4 Setbacks: Front and side setbacks must be consistent with surrounding buildings. Non-
compliant for Lots 1-2
• 5.1.5 Adjacent Lots: Grading between lots to be sensitively considered. Non-compliant for Lots
3-6
E. Utilities and Trash Containment:
• 5.2.1 Underground Utilities: Compliance presumed
• 5.2.2 Solid Waste Storage Areas: Sutera location shown on plan - compliant
• 5.2.3 Mechanical and Utility Equipment: Compliance to be confirmed with final approval
F. Building Standards:
• 6.1.1 General Design Principles - Connectivity: Not applicable
• 6.1.2 General Design Principles - Housing: Not applicable
• 6.1.3 General Design Principles – Mixed-Use Infill & Redevelopment: Not applicable
• 6.1.1 General Design Principles - Downtown Should be Urban: Compliant
• 6.1.5 General Design Principles - Put People First: Streetscapes should be composed of wide
sidewalks for walking, seating, public art, and landscaping. Compliance required – current
drawings do not show the correct streetscape improvements along both street frontages
• 6.2 Required Building Design Standards:
o 6.2.1 Architectural Style: Compliant
o 6.2.2 Compatibility: Compliant
o 6.2.3 Proportions: Compliant
o 6.2.4 Wall Materials: Please confirm
o 6.2.5 Façade Treatment: Compliant
o 6.2.6 Building Entrances: Non-compliant for Lots 3-6
• 6.4 Specific Building Design Standards for all D-T4 and Residential Structures
o 6.3.1 Roof and Eaves: Flat roofs in D-T4 required Discretionary Approval by the DRB
o 6.3.2 Façade Design: Compliance presumed but needs to be confirmed with
measurements
o 6.3.3 Building Entrances: Model depicts intended compliance. Please confirm
compliance with the 2 foot finished floor elevation (FFE) over existing grade for Lots 1-2
and 7-10 with dimensions on the elevation drawings
Page 12 of 37
214 Oakland Avenue
Spartanburg Design Review Board
12/21/23
www.arcadis.com
DRB - 214 Oakland Avenue - DRB Preliminary Review-122123 3/4
o 6.4.4 Garages
▪ a. Garage Setbacks: Garages on Lots 3-6 are not recessed a minimum of 5 ft
▪ b. Garage Width: Garages on Lots 3-6 may not exceed 50% of the façade width
o 6.3.5 Materials: Compliant
G. Parking:
• Parking Area Access: Parking is provided via a rear court/alley
H. Streetscape and Site Landscaping:
• 8.1 Required Streetscape:
o D-T4: 11 ft zone with 6 foot planting strip; trees every 50 ft; and a 5 ft sidewalk – Correct
drawings to show compliance with standards
o D-T5: 12 ft/14 ft without tree wells; 8 ft sidewalk; trees in wells – Correct drawings to
show compliance with standards
I. Signage: Not applicable.
ADDITIONAL COMMENTS AND SUGGESTIONS FOR BOARD CONSIDERATION
• Internal Units without Street Frontage/Courtyard Fronting Homes: The current plans show Lots 3-6
to be internal and have no street frontage. Garage access is from the alley/court but the front doors are
around the back side of the buildings facing some unattractive elements of the adjacent buildings and
providing poorly accessible guest access. We believe that an appropriate design solution would be to
adjust the plans for those 4 units to provide a front door and a garage from the interior court. The plans
have already been adjusted to replace a typical asphalt alley with pavers to create a courtyard aesthetic.
There are several good built examples using this detail and we believe that it would dramatically improve
the marketability of the units and the livability of the residents. Based on our correspondence with the
design team, it is our expectation that they will also adjust the unit design accordingly. Presuming this
adjustment, we support this configuration.
An example of an interior court on a paver court with units with front loading garages is depicted below.
Page 13 of 37
214 Oakland Avenue
Spartanburg Design Review Board
12/21/23
www.arcadis.com
DRB - 214 Oakland Avenue - DRB Preliminary Review-122123 4/4
• North facing elevation of Lot 2: Because the unit is set forward of its neighbor to the north, the side
elevation will be more exposed. Based on the submitted models, we believe that the number and
placement of the windows is sufficient to avoid any blank wall condition that would be highly visible to
anyone heading south on Oakland Avenue.
• Existing 20 inch Water Oak Street in the front yard of Lot 2: There is a large canopy tree in the front
yard of Lot 2 that appears to have a healthy canopy. A tree of this size is of great benefit to the entire
neighborhood and its preservation is strongly encouraged. Given the minimal setback, it is likely that
there would not be sufficient root zone remaining for it to remain healthy, however, we believe that it is
worth the retention of an arborist to consider options to save it. It would add immediate financial value to
the new units and continue to provide shade and rainwater benefits to the entire neighborhood.
RECOMMENDATION
We recommend preliminary approval conditioned on the modifications noted above.
Craig Lewis, FAICP, LEED AP, CNU-A
Phone: 704-609-9841
craig.lewis@arcadis.com
Page 14 of 37
Page 15 of 37
Page 16 of 37
Page 17 of 37
Oakland Ave.
E. St. John St.
Page 18 of 37
OAKLAND AVENUE TOWNHOMES
Page 19 of 37
OAKLAND AVENUE TOWNHOMES
Page 20 of 37
OAKLAND AVENUE TOWNHOMES
Page 21 of 37
OAKLAND AVENUE TOWNHOMES
Page 22 of 37
OAKLAND AVENUE TOWNHOMES
Page 23 of 37
OAKLAND AVENUE TOWNHOMES
Page 24 of 37
OAKLAND AVENUE TOWNHOMES
Page 25 of 37
OAKLAND AVENUE TOWNHOMES
Page 26 of 37
OAKLAND AVENUE TOWNHOMES
Page 27 of 37
ECO-PRIORA PERMEABLE PAVER SYSTEM (OR EQUIVALENT):
Page 28 of 37
Page 29 of 37
Page 30 of 37
Page 31 of 37
Page 32 of 37
N/F
NITTEL PROPERTIES LLC
TMS# 7-12-07-116.00
DB: 115L, PG: 38
10' ALLEY R/W
N/F
CITY OF SPARTANBURG
& COS C/O
TMS# 7-12-07-095.00
DB:83S, PG:975
ROCK
WALL
30" WATER OAK
CHAIN LINK FENCE
BRICK
PLANTER
BRICK
WALL
N/F
HARRY & AMY CORBIN
TMS# 7-12-07-119.00
DB:115B, PG:513
EDGE OF PAVEMENT
OAKLAND AVENUE
40' PUBLIC R/W
CATCH BASIN
(Inaccessible)
RIM = 774.61'
ST. JOHN ST (US 29)
VARIABLE PUBLIC R/W
CONCRETE MEDIAN
PLANTER
EDGE OF PAVEMENT
WATER
VALVES
TRAFFIC
SIGNAL POLE
TRAFFIC
SIGNAL BOX
CURB
ISLANDS
CP
RBF
RBF
RBF
RBF
IRF
RBS
CP
SSMH
RIM = 782.24'
Inv. In = 777.54'
Inv. Out = 777.40'
± 118 lf 8" PVC @ 0.98%
SSMH
RIM = 784.15'
Inv. In = 778.85'
Inv. In = 778.80'
Inv. Out = 778.70'
CP
SDMH
RIM = 784.45'
Inv. In = 779.05' (15" RCP)
Inv. In = 776.70' (18' RCP)
Inv. Out = 776.60' (18" RCP)
SDMH
RIM = 767.70'
Inv. In = 761.95' (18" RCP)
Inv. In = 756.40' (48" RCP)
Inv. Out = 756.30' (48" RCP)
± 350 lf 18" RCP @ 4.18%
WATER
METER
HORZ. SCALE:
VERT. SCALE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
DATE:
www.sitedesign-inc.com
1074 ASHEVILLE HWY UNIT B
GREENVILLE, SC 29615
PH: (864)285-0618
CIVIL ENGINEERS - SURVEYORS - LANDSCAPE ARCHITECTS
DEMOLITION NOTES
1. DEMOLITION AND REMOVAL IS NOT NECESSARILY LIMITED TO THE ITEMS SHOWN
ON THIS PLAN. CONTRACTOR SHALL REMOVE ADDITIONAL EXISTING UNSUITABLE
MATERIAL OR STRUCTURES WITHIN THE CONSTRUCTION AREA AS NECESSARY.
2. THE CONTRACTOR SHALL NOTIFY THE OWNER IMMEDIATELY IF UNDERGROUND
STORAGE TANKS OR OTHER EQUIPMENT IS UNEARTHED OR OTHERWISE
DISCOVERED.
3. ALL EXISTING UTILITY DEMOLITION, REMOVAL, OR ABANDONMENT (WATER,
SEWER, STORM DRAINAGE, ELECTRIC, GAS, TELEPHONE, CABLE, ETC.) SHALL BE
DONE IN ACCORDANCE WITH THE STANDARDS, RULES, REGULATIONS, AND
REQUIREMENTS OF THE APPLICABLE GOVERNING UTILITY ENTITY. CONTRACTOR
SHALL COORDINATE UTILITY WORK WITH THE APPROPRIATE UTILITY ENTITY.
CONTRACTOR TO VERIFY USEFULNESS OF EXISTING SITE UTILITIES WITH THE
APPROPRIATE UTILITY ENTITY.
4. THE CONTRACTOR SHALL OBTAIN ALL PERMITS FROM CITY OF SPARTANBURG
NECESSARY OR REQUIRED TO PERFORM DEMOLITION. THE CONTRACTOR IS
RESPONSIBLE FOR THE PROPER DISPOSAL OF DEMOLITION DEBRIS.
5. THE CONTRACTOR SHALL CONDUCT ALL DEMOLITION, REMOVAL, STORAGE,
CLEANUP, ETC. IN ACCORDANCE WITH ALL REGULATING AUTHORITIES INCLUDING
BUT NOT LIMITED TO CITY OF SPARTANBURG, SCDHEC, AND THE U.S.
ENVIRONMENTAL PROTECTION AGENCY.
6. NO WORK MAY BE PERFORMED WITHIN THE STATE RIGHT-OF-WAY WITHOUT AN
APPROVED SCDOT ENCROACHMENT PERMIT.
7. EVERY ATTEMPT TO RECYCLE DEMOLISHED MATERIALS SHOULD BE MADE.
COORDINATE WITH ON-SITE CONSTRUCTION MATERIALS TESTING FIRM TO
IDENTIFY ANY MATERIAL TO BE RECYCLED.
11. ALL EXISTING DRIVEWAYS AND CURB CUTS THAT ARE NOT USED SHALL BE
REMOVED AND REPLACED WITH A CONCRETE CURB, GUTTER, AD/OR SIDEWALK (IF
EXISTING).
12. SAWCUT EDGE OF ALL PAVEMENT TYPES WHERE CONNECTIONS ARE TO BE MADE.
IF ASPHALT IS DAMAGED AT POINT OF CONNECTION, A PATCH WILL BE REQUIRED
BY MILLING 2" DEPTH AT A MINIMUM WIDTH OF 6.5' FOR THE ENTIRE LENGTH OF
THE DAMAGED SECTION. IF ADJACENT SIDEWALK IS DAMAGED AT CONNECTION,
THEN THAT SECTION WILL BE REMOVED AND REPLACED FROM JOINT TO JOINT.
Know what's below.Call before you dig.
HATCHING DENOTES
REMOVAL OF ON-SITE
IMPERVIOUS AREA
± 16,500 S.F. OF PAVEMENT,
SIDEWALK & CURB REMOVAL
ABANDON
CATCH BASIN
ZONING: DT-3
ZONING: CIVIC
ZONING: DT-5
SAWCUT EDGE OF
PAVEMENT TO
PROVIDE CLEAN JOINT
BRICK WALL
TO REMAIN
COORDINATE REMOVAL OF
EXISTING LIGHT AND POWER
W/ DUKE ENERGY
REMOVE EXISTING
CHAIN LINK FENCE
REMOVE
EXISTING TREE
DEMO WALL
REMOVE EXISTING
CURBING WITHIN SITE
LIMITS
REMOVE EXISTING
CURBING WITHIN SITE
LIMITS
REMOVE EXISTING
CURBING WITHIN SITE
LIMITS
REMOVE EXISTING
CURBING WITHIN SITE
LIMITS
EXISTING
GAS MAIN
EXISTING 14"
WATER MAIN
15' ELECTRICAL EASEMENT
Page 33 of 37
N/F
NITTEL PROPERTIES LLC
TMS# 7-12-07-116.00
DB: 115L, PG: 38
10' ALLEY R/W
N/F
CITY OF SPARTANBURG
& COS C/O
TMS# 7-12-07-095.00
DB:83S, PG:975
N/F
HARRY & AMY CORBIN
TMS# 7-12-07-119.00
DB:115B, PG:513
OAKLAND AVENUE
40' PUBLIC R/W
ST. JOHN ST (US 29)
VARIABLE PUBLIC R/W
CONCRETE MEDIAN
HORZ. SCALE:
VERT. SCALE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
DATE:
www.sitedesign-inc.com
1074 ASHEVILLE HWY UNIT B
GREENVILLE, SC 29615
PH: (864)285-0618
CIVIL ENGINEERS - SURVEYORS - LANDSCAPE ARCHITECTS
Know what's below.Call before you dig.
ZONING: DT-4
22'X40' UNIT
(TYP.)
18" ROLLED
CURB (TYP.)
22.0'
40.0'
20.0'
20.0'
88.0'
40.0'
40.0'
40.0'
44.0'
PROPOSED MAIL
KIOSK LOCATION
5.0'
5' SIDEWALK
(TYP.)
15' ELECTRICAL EASEMENT
SITE DATA:
TM#: 7-12-07-118.00
TM#: 7-12-07-117.00
PROPOSED ZONE: DT-5/DT-4
OAKLAND AVE: LOCAL
E. SAINT JOHN ST: SCDOT ROAD
TOTAL SITE = 0.52 AC
OPEN SPACE = 0.079 AC (15.2%)
TOTAL NUMBER OF UNITS: 10
SETBACKS - (MINIMUM REQUIREMENTS)
FRONT - 0'
REAR - 0'
SIDES - N/A
2 STALL
GARAGE
(TYP.)
EXISTING
SIGN
33.0'
PRIVATE
R/W
33.0'PRIVATE
R/W
UNIT 1
UNIT 2
UNIT 3
UNIT 4
UNIT 5
UNIT 6
UNIT 7
UNIT 8
UNIT 9
UNIT 10
22.0'
22.0'
22.0'
22.0'
22.0'
22.0'
22.0'
R20.0'
(TYP.)
4.5'
4.5'
123.1'
22'X40' UNIT
(TYP.)
6' WIDE PLANTING
STRIP
14.0'
STREETSCAPEZONE
TRANSITION 6'
SIDEWALK INTO
EXISTING
PROPOSED 6'
SIDEWALK
SUTERA
UNDERGROUND
TRASH
WALL (TYP.)
(DESIGNED BY
OTHERS)
ZONING: CIVIC
ZONING: DT-5
BUILDING ON
CRAWL SPACE OR
FOUNDATION WALL
WALL
(DESIGN BY
OTHERS)
BUILDING ON
CRAWL SPACE OR
FOUNDATION WALL
WALL
(DESIGN BY
OTHERS)
ECO-PRIORA PERVIOUS
PAVER SYSTEM OR
EQUIVALENT
PROPOSED 6'
PLANTER STRIP
Page 34 of 37
N/F
NITTEL PROPERTIES LLC
TMS# 7-12-07-116.00
DB: 115L, PG: 38
10' ALLEY R/W
N/F
CITY OF SPARTANBURG
& COS C/O
TMS# 7-12-07-095.00
DB:83S, PG:975
BRICK
PLANTER
BRICK
WALL
N/F
HARRY & AMY CORBIN
TMS# 7-12-07-119.00
DB:115B, PG:513
OAKLAND AVENUE
40' PUBLIC R/W
ST. JOHN ST (US 29)
VARIABLE PUBLIC R/W
CONCRETE MEDIAN
WATER
VALVES
TRAFFIC
SIGNAL BOX
SSMH
RIM = 782.24'
Inv. In = 777.54'
Inv. Out = 777.40'
± 118 lf 8" PVC @ 0.98%
SSMH
RIM = 784.15'
Inv. In = 778.85'
Inv. In = 778.80'
Inv. Out = 778.70'
(782)
(783)
(784)
(780) (781) (782) (783)
40LF-18"RCP @ 10.20%
HW 1
IE: 774.04
CB 1
COMBO
RIM EL.: 781.79
IE OUT: 778.08
FF ELEV:
783.50
FF ELEV:
783.50
FF ELEV:
782.75
FF ELEV:
782.75
FF ELEV:
783.25
FF ELEV:
783.25
FF ELEV:
783.00
FF ELEV:
783.00
FF ELEV:
782.50
FF ELEV:
782.50
TW: 782.50
BW: 778.00
TW: 782.93
BW: 777.70
TW: 782.93
BW: 775.86
BW: 778.44
TW: 782.99
BW: 778.45
TW: 782.98
BW: 780.35
TW: 781.35
TW: 782.35
BW: 780.21
BW: 780.06
TW: 782.35
TW: 782.27
TW: 782.17
BW: 779.19
BW: 779.58
BW: 779.94
HORZ. SCALE:
VERT. SCALE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
DATE:
www.sitedesign-inc.com
1074 ASHEVILLE HWY UNIT B
GREENVILLE, SC 29615
PH: (864)285-0618
CIVIL ENGINEERS - SURVEYORS - LANDSCAPE ARCHITECTS
Know what's below.Call before you dig.
GRADING NOTES:
1. THE CONTRACTOR SHALL VERIFY THE LOCATION OF ALL UNDERGROUND
UTILITIES BY CALLING UTILITY LOCATION SERVICE AT 811 THREE (3) DAYS PRIOR
TO CONSTRUCTION.
2. THE CONTRACTOR SHALL NOTIFY THE ENGINEER FOR A REVIEW SHOULD ANY
DISCREPANCIES BE DISCOVERED AT THE SITE OR ON THE DRAWINGS.
3. PROOFROLLING AND COMPACTION TESTS SHALL BE ACCOMPLISHED IN THE
FIELD TO TEST FILLED AREAS. INITIAL COMPACTION TESTS WILL BE CONDUCTED
AT OWNER'S EXPENSE. RETESTING REQUIRED BECAUSE OF POOR COMPACTION
SHALL BE CONDUCTED AT CONTRACTOR'S EXPENSE. CONTRACTOR SHALL
SUPPLY RESULTS TO THE ENGINEER BEFORE ANY PRELIMINARY AND/OR FINAL
APPROVALS.
4. THE GRADING CONTRACTOR SHALL PROOFROLL THE CONSTRUCTION AREA
WITH HEAVY RUBBER-TIRED EQUIPMENT. ALL SOFT SPOTS SHALL BE
STABILIZED BY FURTHER COMPACTIVE EFFORT OR UNDERCUT AND BACKFILLED
WITH COMPACTED STRUCTURAL FILL MATERIAL.
5. EARTHWORK SHALL BE TO THE GRADES AND LINES SHOWN. EXISTING AND
PROPOSED CONTOUR INTERVALS ARE AT 1'.
6. ALL NEW ELEVATIONS SHOWN ARE FINISH ELEVATIONS. THE GRADING
CONTRACTOR SHALL DEDUCT THE APPROPRIATE AMOUNT TO ESTABLISH
SUBGRADE ELEVATION.
7. WALL ELEVATIONS WHERE NOTED ARE TOP OF WALL AND FINISH GRADE AT
BOTTOM OF WALL. SEE RETAINING WALL PLANS FOR DETAILED CONSTRUCTION
INFORMATION.
8. CONTRACTOR SHALL REMOVE TOPSOIL AS NECESSARY (MINIMUM OF 4") TO
PROVIDE ADEQUATE SUBGRADE FOR ROADWAYS.
9. ALL EXCAVATION SHALL BE "UNCLASSIFIED EXCAVATION". ALL NEW FILL AND
UTILITY TRENCH BACKFILL SHALL BE COMPACTED TO AT LEAST 95% OF
MAXIMUM DRY DENSITY AS DETERMINED BY THE STANDARD PROCTOR (ASTM
D-698). IN ADDITION, THE UPPER 18" OF ALL FILL MATERIALS BENEATH FLOOR
SLABS AND PAVEMENTS SHALL BE COMPACTED TO AT LEAST 98% OF THE
MAXIMUM DRY DENSITY (ASTM D-698).
10. THE CONTRACTOR SHALL CONDUCT ALL WORK IN ACCORDANCE WITH THE
LATEST REQUIREMENTS OF THE OCCUPATIONAL SAFETY AND HEALTH
ADMINISTRATION.
11. ALL REINFORCED CONCRETE PIPE SHALL BE CLASS III, UNLESS OTHERWISE
NOTED, AND SHALL CONFORM TO SCDOT SPECIFICATIONS. ALL JOINTS SHALL
BE TONGUE AND GROOVE WITH MASTIC MATERIAL.
12. CATCH BASINS SHALL BE PRECAST R.EINFORCED CONCRETE DRAINAGE BOX
WITH SOLID WALL PER SCDOT STANDARD DRAWING 719-17A OR APPROVED
EQUAL.
13. ALL WORK ON STATE, COUNTY, OR CITY RIGHT-OF-WAYS, INCLUDING DRIVEWAY
APRONS, WATER AND SEWER TAPS OR ANY OTHER WORK REQUIRES AN
ENCROACHMENT PERMIT FROM THE APPROPRIATE AGENCY.
14. STANDING GRASS MUST BE EVIDENT IN AREAS THAT WERE SEEDED.
15. AN AS-BUILT CERTIFICATION OF THE STORMWATER MANAGEMENT SYSTEM WILL
BE REQUIRED PRIOR TO ISSUANCE OF A CERTIFICATE OF OCCUPANCY FOR THE
SITE. THE DESIGN ENGINEER WILL NOT BE RESPONSIBLE FOR THE DELAYS
RESULTING FROM NON-COMPLIANCE WITH THE DESIGN DRAWINGS.
16. CONTRACTOR TO CONFIRM ALL ELEVATIONS AND ADA COMPLIANCE PRIOR TO
INSTALLING CURB, SIDEWALK, OR PAVEMENT AND BRING ANY DISCREPANCIES
TO THE ENGINEER'S ATTENTION.
NOTES:
1. SLOPES WITHIN ADA PARKING AREAS CANNOT EXCEED 2% IN ANY DIRECTION.
ALL ADA PARKING AREAS ARE TO BE CONSTRUCTED WITH CONCRETE.
2. SIDEWALK CROSS SLOPES ARE NOT TO EXCEED 2%.
3. ANY SIDEWALK EXCEEDING 5% RUNNING SLOPE IS CONSIDERED A RAMP. ANY
RAMP RISING GREATER THAN 6" MUST HAVE AN ADA APPROVED HANDRAIL ON
BOTH SIDES. RAMPS MUST NOT EXCEED 8% RUNNING SLOPE.
4. ANY EXCESS SOIL HAULED OFF-SITE MUST BE TO AN APPROVED PERMITTED SITE.
5. SPOT ELEVATIONS SHOWN DENOTE BOTTOM OF CURB, TOP OF ASPHALT, OR
GROUND SURFACE ELEVATION UNLESS OTHERWISE NOTED.
6. TC = TOP OF CURB / BC = BOTTOM OF CURB.
7. TW = TOP OF WALL / BW = BOTTOM OF WALL.
8. BUILDING ROOF DRAINAGE WILL TIE TO UNDERGROUND STORMWATER DRAINAGE
SYSTEM. COORDINATE WITH MEP PLANS.
I have placed my signature and seal on the design documents
submitted signifying that I accept responsibility for the design
of the system. Further, I certify to the best of my knowledge
and belief that the design is consistent with the requirements
of Title 48, Chapter 14 of the Code of Laws of SC, 1976 as
amended, pursuant to Regulation 72-300 et seq. (if applicable),
and in accordance with the terms and conditions of SCR100000
Page 35 of 37
N/F
RECONCILIATION
HOLDINGS LLC
TMS# 7-12-07-120.00
DB:82S, PG:965
N/F
NITTEL PROPERTIES LLC
TMS# 7-12-07-116.00
DB: 115L, PG: 38
10' ALLEY R/W
N/F
CITY OF SPARTANBURG
& COS C/O
TMS# 7-12-07-095.00
DB:83S, PG:975
BRICK
PLANTER
BRICK
WALL
N/F
HARRY & AMY CORBIN
TMS# 7-12-07-119.00
DB:115B, PG:513
OAKLAND AVENUE
40' PUBLIC R/W
ST. JOHN ST (US 29)
VARIABLE PUBLIC R/W
PROPERTY LINE IS
TO BE DELETED
UPON RECORDING
CONCRETE MEDIAN
WATER
VALVES
N 14°16'27" W 53.40'
N 19°27'01" W 52.26'
N 74°35'18" E 57.07'
S 75°55'44" W 90.37'
S 75°43'32" W 102.04'
N 15°07'48" W 47.07'
N 75°36'29" E 140.55'
S 76°30'06" W 140.13'
SSMH
RIM = 782.24'
Inv. In = 777.54'
Inv. Out = 777.40'
± 118 lf 8" PVC @ 0.98%
SSMH
RIM = 784.15'
Inv. In = 778.85'
Inv. In = 778.80'
Inv. Out = 778.70'
S 14°14'54" E 105.00'
S 14°35'19" E 49.25'
22,451.14± Sq. Feet
0.52± Acres
Total Combined Acreage
6,757.33± Sq. Feet
0.16± Acres
15,693.82± Sq. Feet
0.36± Acres
46LF-8"PVC @ 0.50%
100LF-8"PVC @ 0.50%
SSMH #2
STA: 1+00.31
RIM EL.: 782.24
IE IN: 778.45
IE OUT: 778.25
SSMH #3
STA: 1+45.82
RIM EL.: 782.38
IE OUT: 778.68
SSMH #1
STA: 0+00.00
RIM EL.: 783.08
IE IN: 778.00
IE IN: 777.75
IE OUT: 778.00
HORZ. SCALE:
VERT. SCALE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
DATE:
www.sitedesign-inc.com
1074 ASHEVILLE HWY UNIT B
GREENVILLE, SC 29615
PH: (864)285-0618
CIVIL ENGINEERS - SURVEYORS - LANDSCAPE ARCHITECTS
Know what's below.Call before you dig.
EXISTING
POLE TO
REMAIN
UTILITY NOTES:
1. ALL UTILITIES LOCATED ON THIS PLAN SHOULD BE CONSIDERED APPROXIMATE.
CONTRACTOR SHALL COORDINATE LOCATION OF UNDERGROUND UTILITIES
WITH THE UTILITY LOCATING SERVICE, BY CALLING 811 THREE (3) DAYS PRIOR
TO CONSTRUCTION, AND UTILITY PROVIDERS.
2. CONTRACTOR SHALL NOTIFY THE ENGINEER FOR A REVIEW SHOULD ANY
DISCREPANCIES BE DISCOVERED AT THE SITE OR ON THE DRAWINGS.
3. NEW UTILITY TRENCH BACKFILL SHALL BE COMPACTED TO AT LEAST 95% OF
MAXIMUM DRY DENSITY AS DETERMINED BY THE STANDARD PROCTOR TEST
(ASTM D-698). IN ADDITION, THE UPPER 18" OF ALL FILL MATERIALS BENEATH
FLOOR SLABS AND PAVEMENTS SHALL BE COMPACTED TO AT LEAST 98% OF
THE MAXIMUM DRY DENSITY (ASTM D-698).
4. CONTRACTOR SHALL CONSTRUCT DOMESTIC WATER SERVICE TO BUILDINGS
SHOWN ON DRAWING. EXACT LINE SIZE, TYPE AND LOCATION TO BE
COORDINATED WITH MEP PLANS AND THE GOVERNING UTILITY AUTHORITY.
TAPS TO BE INSTALLED TO THE SPECIFICATIONS OF THE GOVERNING UTILITY
AUTHORITY.
5. CONTRACTOR SHALL CONSTRUCT SANITARY SEWER SERVICE TO BUILDINGS.
EXACT SIZE, TYPE AND LOCATION TO BE COORDINATED WITH MEP PLANS AND
THE GOVERNING UTILITY AUTHORITY. SERVICE TO BE INSTALLED TO THE
SPECIFICATIONS OF THE GOVERNING UTILITY AUTHORITY. INSTALL CLEAN
OUTS AT 75' INTERVALS (MAX) AND AT ALL DEFLECTIONS.
6. CONTRACTOR SHALL COORDINATE ALL OTHER UTILITY CONNECTIONS WITH
LOCAL PROVIDERS. CONTRACTOR SHALL INSTALL ALL UTILITIES TO THE
SPECIFICATIONS AND REQUIREMENTS OF THE ACCEPTING UTILITY AUTHORITY.
7. THE CONTRACTOR SHALL CONDUCT ALL WORK IN ACCORDANCE WITH THE
LATEST REQUIREMENTS OF THE OCCUPATIONAL SAFETY AND HEALTH
ADMINISTRATION.
8. THE CONTRACTOR SHALL PROVIDE ALL NECESSARY UTILITY SCREENING TO
MEET THE REQUIREMENTS OF THE CITY OF SPARTANBURG.
9. OWN/ER/DEVELOPER TO CONTACT SPARTANBURG WATER NEW CONNECTIONS
AT 864-583-7361 TO SETUP SMALL METER CONNECTION.
10. OWNER/DEVELOPER TO CONTACT SPARTANBURG WATER NEW CONNECTIONS
AT 864-583-7361 TO COORDINATE CONNECTION OF SEWER LATERAL
EXISTING
HYDRANT
ASSEMBLY
BLOW OFF TAP
AT END OF
EXTENSION
PROPOSED
4"x4" TEE
BLOW OFF TAP
AT END OF
EXTENSION
4" DIP
WATER MAIN
4" DIP
WATER MAIN
PROPOSED 14"x4"
TAPPING SLEEVE
& GATE VALVE
R400'
HYDRANT RADIUS
Page 36 of 37
OAKLAND AVENUE
40' PUBLIC R/W
ST. JOHN ST (US 29)
VARIABLE PUBLIC R/W
WATER
VALVES
SDMH
RIM = 784.45'
Inv. In = 779.05' (15" RCP)
Inv. In = 776.70' (18' RCP)
Inv. Out = 776.60' (18" RCP)
HORZ. SCALE:
VERT. SCALE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
DATE:
www.sitedesign-inc.com
1074 ASHEVILLE HWY UNIT B
GREENVILLE, SC 29615
PH: (864)285-0618
CIVIL ENGINEERS - SURVEYORS - LANDSCAPE ARCHITECTS
Know what's below.Call before you dig.
(678)
ZONING: DT-3
15' ELECTRICAL EASEMENT
SITE DATA:
TM#: 7-12-07-118.00
TM#: 7-12-07-117.00
PROPOSED ZONE: D-T5
OAKLAND AVE: LOCAL
E. SAINT JOHN ST: SCDOT ROAD
TOTAL SITE = 0.52 AC
OPEN SPACE = 0.079 AC (15.2%)
TOTAL NUMBER OF UNITS: 10
SETBACKS - (MINIMUM REQUIREMENTS)
FRONT - 0'
REAR - 0'
SIDES - N/A
UNIT 1
UNIT 2
UNIT 3
UNIT 4
UNIT 5
UNIT 6
UNIT 7
UNIT 8
UNIT 9
UNIT 10
ZONING: CIVIC
ZONING: DT-5
(6) POMA
(2) QUNU
(1) CCME
(5) BUGV
(2) CCME
(5) GAKH
STREET FRONTAGE BUFFER:
REQUIRED PER 100
1 CANOPY
2 ORNAMENTAL
4 LARGE OR 8 SMALL EVERGREEN SHRUBS
121.2'/100
1.2 CANOPY REQUIRED
2 CANOPY PROVIDED
2.4 ORNAMENTAL REQUIRED
3 ORNAMENTAL PROVIDED
9.7 SMALL EVERGREEN REQUIRED
10 SMALL EVERGREEN PROVIDED
StateofSouth
Carolina
ALISON
G.BRANDT
REGISTEREDLANDSCAPEARCHITECT
No. 552
LANDSCAPE NOTES:
1.PLANT SCHEDULE, GENERAL
NOTES, DETAILS ON PAGE L200
2.NO BUFFER REQUIRED
(7) DIBC
(12) BUGV
(9) DIBC
(9) GAKH
SYMBOL CODE QTY BOTANICAL NAME COMMON NAME SIZE REMARKS
SHRUBS
BUGV 12 Buxus x `Green Velvet` Green Velvet Boxwood 3 gal 18" Ht. Min.
DIBC 16 Distylium x 'PIIDIST-II' Blue Cascade® Distylium 3 gal 18" Ht. Min.
GAKH 9 Gardenia jasminoides `Kleim`s Hardy` Kleim`s Hardy Gardenia 3 gal 18" Ht. Min.
PLANT SCHEDULE SUPPLEMENTAL PLANTINGS
SYMBOL CODE QTY BOTANICAL NAME COMMON NAME SIZE REMARKS
TREES
POMA 6 Podocarpus macrophyllus 'Maki' Maki Yew Podocarpus 4` Ht.
QUNU 2 Quercus nuttallii Nuttall Oak 2 1/2" cal, 14` ht 6` Clear Trunk
ORNAMENTAL TREE
CCME 3 Cercis canadensis `Merlot` Merlot Redbud 2" Cal. 10` Ht. Min. 5' Clr Trunk
SHRUBS
BUGV 17 Buxus x `Green Velvet` Green Velvet Boxwood 3 gal 18" Ht. Min.
DIBC 16 Distylium x 'PIIDIST-II' Blue Cascade® Distylium 3 gal 18" Ht. Min.
GAKH 14 Gardenia jasminoides `Kleim`s Hardy` Kleim`s Hardy Gardenia 3 gal 18" Ht. Min.
PLANT SCHEDULE
ECO-PRIORA PERVIOUS
PAVER SYSTEM OR
EQUIVALENT
Page 37 of 37
Source: City of Spartanburg website. First collected Nov 8, 2026.