Planning Commission — Other
City of Spartanburg · Spartanburg County · Boards and Commissions · meeting of Dec 21, 2023 · Other
Open the original document More from City of Spartanburg
Text
Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.
VAN
SITE OVERVIEWCOKE FACILITY REDEVELOPMENT PHASE 1SPARTANBURG, SOUTH CAROLINATMS# 7-12-13-024.00, 7-12-13-001.00
OWNER/DEVELOPER:PALMETTO OPERATING COMPANY, LLC101 E WASHINGTON ST, SUITE 400GREENVILLE, SC 29601CONTACT: BRETT BAUMGARTENPHONE: (916) 719-1900STORM WATER:CITY OF SPARTANBURG801 UNION STSPARTANBURG, SC 29302CONTACT: JAY SQUIRESPHONE: (864) 596-2089
CIVIL ENGINEER & LANDSCAPE ARCHITECT:SEAMON WHITESIDE & ASSOCIATES, LLC104 N DANIEL MORGAN AVE, SUITE 300SPARTANBURG, SC 29301CONTACT: DANNY BALON, PEPHONE: (864) 272-1272SURVEYOR:EAS PROFESSIONALS, INC.9 PILGRIM RDGREENVILLE, SC 29607CONTACT: JUSTIN KILEPHONE: (864) 234-7368PROJECT CONTACTS
WATER SERVICE:SPARTANBURG WATER175 N LIBERTY STSPARTANBURG, SC 29306CONTACT: KEVIN SMITHPHONE: (864) 580-5683
GENERAL NOTESPROJECT DESCRIPTION
SITE LOCATION MAP
SEWER SERVICE:SPARTANBURG WATER175 N LIBERTY STSPARTANBURG, SC 29306CONTACT: JOEL WATSONPHONE: (864) 580-5683
SHEET REVISION HISTORY#
C1.0TITLESHEETA10/14/22H05/04/2302/16/23BC02/21/23D03/27/23E03/30/23F04/12/23G04/27/2305/17/23IJ06/02/23 SCALE: 1" = 100'050100200SEWN R
Know what'sbelow.before you dig.Call
PROJECT SURVEY INFORMATION AND CONTRACTOR VERIFICATION REQUIREMENTS1.BOUNDARY, TOPOGRAPHIC, TREE, WETLAND DELINEATION, AND OTHER EXISTING CONDITIONS SHOWN AREFROM SURVEY PREPARED BY EAS PROFESIONALS, INC. DATED DECEMBER 16, 2022. THE TOPOGRAPHICAND ELEVATION DATA SHOWN HEREON WAS OBTAINED FROM THE REFERENCED SURVEY AND IS NOTCERTIFIED AS CORRECT BY THIS ENGINEER.2.PER REFERENCE SURVEY, ALL ELEVATIONS ARE BASED ON NAVD88 VERTICAL DATUM. HORIZONTAL DATUMIS STATE PLANE (SC NAD83). REFER TO SURVEY FOR BENCHMARK REFERENCE AND/OR LOCATION.CONTACT OWNER FOR ANY MISSING BOUNDARY PINS, MONUMENTS, OR VERTICAL DATUM BENCHMARKSNEEDED FOR ESTABLISHING CONSTRUCTION STAKING CONTROL.3.THE CONTRACTOR IS RESPONSIBLE FOR LOCATING ALL PERIMETER BOUNDARY PROPERTY CORNERS ANDVERIFYING BOUNDARY DATA AGAINST CONSTRUCTION PLANS AND/OR ELECTRONIC FILE INFORMATIONPROVIDED TO THE CONTRACTOR.4.PRIOR TO STARTING CONSTRUCTION, INCLUDING LAND DISTURBING ACTIVITIES, THE CONTRACTOR ISRESPONSIBLE FOR VERIFYING EXISTING CONDITIONS, INCLUDING BUT NOT LIMITED TO TOPOGRAPHIC,TREE, STORM DRAINAGE FACILITIES, AND ALL UTILITIES. EXISTING UTILITIES SHOWN ARE APPROXIMATE ANDHAVE NOT BEEN INDEPENDENTLY VERIFIED BY THE OWNER OR ENGINEER. THEREFORE, THE CONTRACTORIS RESPONSIBLE FOR VERIFYING THE EXACT VERTICAL AND HORIZONTAL LOCATIONS OF ALL EXISTINGUTILITIES. ANY DISCREPANCIES OR CONFLICTS IDENTIFIED DURING VERIFICATION OF EXISTING CONDITIONSAND UTILITIES SHALL BE REPORTED TO THE OWNER AND ENGINEER. ANY COSTS ASSOCIATED WITHCORRECTIVE WORK OR DAMAGES THAT ARE A RESULT OF THE CONTRACTOR NOT VERIFYING EXISTINGCONDITIONS AND THE EXACT VERTICAL AND HORIZONTAL LOCATION OF ALL EXISTING UTILITIES WILL BETHE CONTRACTOR'S RESPONSIBILITY.COPYRIGHT c SEAMON, WHITESIDE & ASSOCIATES, INC.THIS DRAWING SHALL NOT BE REPRODUCED IN ANY MANNER OR USED FOR ANY PURPOSE WITHOUT WRITTEN PERMISSION.
GR4714DBLM/CS10/14/22DATE:
501 WANDO PARK BOULEVARD, SUITE 200 | MOUNT PLEASANT, SC 29464 | 508 RHETT STREET, SUITE 101 | GREENVILLE, SC 29601
500 W MAIN STCITY OF SPARTANBURG, SOUTH CAROLINACOKE FACILITYREDEVELOPMENT PHASE 1REVISION HISTORYDRAWN BY:CHECKED BY:SW+ PROJECT:
MOUNT PLEASANT, SC843.884.1667GREENVILLE, SC864.298.0534
WWW.SEAMONWHITESIDE.COMSUMMERVILLE, SC843.972.0710SPARTANBURG, SC864.272.1272CHARLOTTE, NC980.312.54506/1/23 29
221
THIS PROJECT IS A REDEVELOPMENT OF THE EXISTING FACILITIES ON SITE FOR COMMERCIAL MIXED USEINCLUDING SITE, UTILITY INFRASTRUCTURE, AND STORM DRAINAGE IMPROVEMENTS. THE PROJECT ISLOCATED ON US HIGHWAY 29 (WEST MAIN STREET) IN THE CITY OF SPARTANBURG, SOUTH CAROLINA.SEWN
PLANNING:CITY OF SPARTANBURG440 S CHURCH STSPARTANBURG, SC 29306CONTACT: MARTIN LIVINGSTONPHONE: (864) 580-5323ENERGY SERVICE:DUKE ENERGY920 BEAUMONT AVESPARTANBURG, SC 29303CONTACT: STEVEN PRYORPHONE: (864) 948-5610GAS SERVICE:PIEDMONT NATURAL GAS4720 PIEDMONT ROW DRIVECHARLOTTE, NC 28210CONTACT: DEE DEE HANKSPHONE: (704) 364-3120
PRICING DRAWINGSA10/14/2022
COKE REDEVELOPMENT PHASE 1INDEXC1.0TITLESHEETC1.1GENERAL NOTESC2.0OVERALL EXISTING CONDITIONSC2.1EXISTING CONDITIONSC2.2DEMOLITION PLANC3.0EROSION CONTROL PHASE 1 PLANC3.1EROSION CONTROL PHASE 2 PLANC3.2EROSION CONTROL PHASE 3 PLANC4.0EROSION CONTROL DETAILS (1 OF 2)C4.1EROSION CONTROL DETAILS (2 OF 2)C5.0OVERALL SITE PLANC5.1SITE PLANC5.2SCDOT DRIVEWAY PLANC5.3LIFE SAFETY PLANC6.0GRADING PLANC7.0DRAINAGE PLANC7.1DRAINAGE PROFILESC8.0UTILITY PLAN - WATERC8.1UTILITY PLAN - SEWERC8.2SANITARY SEWER PROFILESC9.0SITE DETAILS (1 OF 3)C9.1SITE DETAILS (2 OF 3)C9.2SITE DETAILS (3 OF 3)C10.0GRADING & DRAINAGE DETAILS (1 OF 2)C10.1GRADING & DRAINAGE DETAILS (2 OF 2)C11.0WATER DETAILSC11.1SEWER DETAILSL1.0LANDSCAPE PLANL2.0PLANT SCHEDULE AND DETAILS
CITY OF SPARTANBURG PERMIT SUBMITTALSB02/16/2023SWS FIRE AND SSSD SEWER SUBMITTALC02/21/2023SCDOT DRIVEWAY ENCROACHMENT SUBMITTALD03/27/2023SPARTANBURG WATER FIRE SUBMITTALE03/30/2023CITY OF SPARTANBURG STORM WATER SUBMITTALF04/12/2023SSSD SEWER RESUBMITTALG04/27/2023SPARTANBURG WATER FIRE RESUBMITTALH05/04/2023SCDOT RESUBMITTALI05/17/2023CITY OF SPARTANBURG RESUBMITTALJ06/02/2023
C1.1GENERALNOTESA10/14/22H05/04/2302/16/23BC02/21/23D03/27/23E03/30/23F04/12/23G04/27/2305/17/23IJ06/02/23
COPYRIGHT c SEAMON, WHITESIDE & ASSOCIATES, INC.THIS DRAWING SHALL NOT BE REPRODUCED IN ANY MANNER OR USED FOR ANY PURPOSE WITHOUT WRITTEN PERMISSION.
GR4714DBLM/CS10/14/22DATE:
501 WANDO PARK BOULEVARD, SUITE 200 | MOUNT PLEASANT, SC 29464 | 508 RHETT STREET, SUITE 101 | GREENVILLE, SC 29601
500 W MAIN STCITY OF SPARTANBURG, SOUTH CAROLINACOKE FACILITYREDEVELOPMENT PHASE 1REVISION HISTORYDRAWN BY:CHECKED BY:SW+ PROJECT:
MOUNT PLEASANT, SC843.884.1667GREENVILLE, SC864.298.0534
WWW.SEAMONWHITESIDE.COMSUMMERVILLE, SC843.972.0710SPARTANBURG, SC864.272.1272CHARLOTTE, NC980.312.54506/1/23 1.THE CONTRACTOR SHALL VERIFY ALL ITEMS TO BE DEMOLISHED AND REMOVED FROM THE PROJECT SITE. THE VERIFICATION PROCESS SHALL INCLUDE VISITING AND WALKING THE SITE. ALL ITEMS REQUIRING DEMOLITION/REMOVAL,WHETHER SHOWN ON THIS PLAN OR NOT, SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR.2.BURNING IS NOT ALLOWED ON-SITE.3.ALL EXISTING STRUCTURES (IF ENCOUNTERED) AND RELATED FOOTINGS, FOUNDATIONS, STEPS, ETC. ARE TO BE REMOVEDFROM THE SITE AND DISPOSED OF ACCORDING TO APPLICABLE CODES.4.THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING THE REMOVAL AND/OR RELOCATION OF ALL UTILITIES (ABOVE AND BELOW GROUND LEVEL) AS NECESSARY TO FACILITATE CONSTRUCTION. SEE THE SPECIFICATIONS FOR SPECIFICDIRECTION.5.EXISTING SEPTIC TANKS, GREASE TRAPS AND/OR UNDERGROUND TANKS, IF ENCOUNTERED, ARE TO BE REMOVED FROM THE SITE AND DISPOSED OF ACCORDING TO APPLICABLE CODES. THE LOCATION OF ANY TANKS SHALL BE RECORDED AND THE ENGINEER SHALL BE NOTIFIED AT ONCE.6. WELLS, IF ENCOUNTERED, SHALL BE ACCURATELY LOCATED BY THE CONTRACTOR, PROTECTED, UNLESS DIRECTEDOTHERWISE ON THESE PLANS AND SURROUNDING GRADES MAINTAINED SUCH THAT SURFACE RUNOFF CANNOT ENTERTHE WELL OPENING. THE CONTRACTOR SHALL NOTIFY THE ENGINEER AT ONCE.7.THE CONTRACTOR SHALL CONSULT THE OWNER REGARDING SALVAGE. ANY ITEMS NOT RETAINED BY THE OWNER SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO DEMOLISH AND/OR LEGALLY DISPOSE OF.8.EROSION AND SEDIMENT CONTROL MEASURES SHALL BE IN PLACE PRIOR TO DEMOLITION AND REMAIN IN PLACE UNTIL FINAL STABILIZATION AND COMPLETION OF CONSTRUCTION ACTIVITIES.9.IF ANY HAZARDOUS MATERIAL IS ENCOUNTERED DURING DEMOLITION, THE CONTRACTOR SHALL COORDINATE WITH THEOWNER AND APPROPRIATE AGENCIES FOR PROPER REMOVAL AND DISPOSAL.10.DEMOLITION SHALL MEET ALL APPLICABLE STATE, LOCAL AND FEDERAL REGULATIONS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING APPLICABLE PERMITS.11.CONTRACTOR IS RESPONSIBLE TO LOCATE ALL UTILITIES AND CONFIRM LOCATION, AND DEPTH IF NECESSARY BY MEAN OF NON DESTRUCTIVE INVESTIGATION (IE. POT HOLING WITH VAC OR WATER). ANY UTILITIES LOCATED BY CONTRACTOR THAT ARE DAMAGED ARE THE RESPONSIBILITY OF THE CONTRACTOR.
DEMOLITION NOTESGENERAL NOTES1.ALL ELEVATIONS ARE BASED ON THE TOPOGRAPHIC SURVEY PROVIDED BY EAS PROFESSIONALS, INC. DATED DECEMBER 16, 2022. 2.THE LOCATIONS OF EXISTING UTILITIES ARE SHOWN IN AN APPROXIMATE WAY ONLY AND HAVE NOT BEEN INDEPENDENTLY VERIFIED BY THE OWNER OR HIS REPRESENTATIVES. EXISTING UTILITIES SHOWN DO NOT INCLUDE ALL UTILITIES THAT MAY EXIST.3.THE CONTRACTOR SHALL BE RESPONSIBLE FOR HAVING ALL EXISTING UNDERGROUND UTILITIES LOCATED WITHIN THIS SITE AND AROUND THE PERIMETER OF THIS SITE WHERE SUCH UTILITIES MIGHT BE OCCASIONED BY ANY ACTIVITY INVOLVED WITH THESE PLANS. ALL UTILITY LOCATION WORK SHALL BE DONE PRIOR TO CONSTRUCTION ACTIVITY, THE CONTRACTOR AGREES TO BE RESPONSIBLE FOR ANY AND ALL DAMAGES WHICH MIGHT BE OCCASIONED BY THE CONTRACTOR'SFAILURE TO LOCATE AND PRESERVE ANY UNDERGROUND UTILITIES THAT MAY EXIST.4.THE CONTRACTOR SHALL VERIFY THE EXISTING TOPOGRAPHY AND EXISTING UTILITY LOCATIONS AND ELEVATIONS PRIOR TO BEGINNING WORK. SHOULD THE CONTRACTOR FIND ANY DISCREPANCIES ON THE DRAWING PRIOR TO BEGINNING WORK OR DURING CONSTRUCTION, HE SHALL NOTIFY THE ENGINEERIMMEDIATELY.5.ALL CONTRACTORS MUST HAVE APPROPRIATE BUSINESS LICENSE PRIOR TO BEGINNING WORK.6.THE PROPERTY IS LOCATED IN THE CITY OF SPARTANBURG, SOUTH CAROLINA.7.THE TOTAL DISTURBED AREA IS ±6.50 ACRES. 8.THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION. AN AUTOCAD FILE OF THIS DRAWING CAN BE PROVIDED TO THE CONTRACTOR FOR CONSTRUCTION LAYOUT PURPOSES. SW+ PROVIDES NO WARRANTY REGARDING USE OF ELECTRONIC FILES. ALL MEASUREMENTS ARE CALCULATED AND NOT SURVEYED UNLESS NOTED OTHERWISE.9.ALL DIMENSIONS ARE TO FACE OF CURB OR EDGE OF PAVEMENT UNLESS OTHERWISE NOTED.10.THE CONTRACTOR IS RESPONSIBLE FOR SITE SAFETY.11.THIS PROPERTY IS LOCATED IN ZONE X AS SCALED FROM FEMA FIRM 45083C0254E.12.CLEARING OUTSIDE OF WHAT IS DEPICTED ON THESE PLANS TO BE CLEARED IS PROHIBITED. CONTRACTOR SHALL BE HELD RESPONSIBLE FOR LAND DISTURBANCES BEYOND THE LIMITS OF DISTURBANCE INDICATED ON THE CONSTRUCTION DOCUMENTS AT THE CONTRACTOR'S EXPENSE.13.THE OWNER SHALL BE RESPONSIBLE FOR ANY SOIL OR MATERIAL TESTING REQUIRED TO MEET SPECIFICATIONS.14.PROVIDE SILT FENCE ALONG THE TOE OF ANY SLOPES OR LOCATIONS WHERE SEDIMENT SHALL DISCHARGE FROM THE SITE. SEE EROSION CONTROL PLAN FOR SPECIFIC LOCATIONS.15.TREE PROTECTIVE BARRICADES (WHERE NOTED ON PLAN) SHALL BE PLACED AROUND ALL TREES TO REMAIN DURING ALL PHASES OF CONSTRUCTION UNTIL DEVELOPMENT ACTIVITIES ARE COMPLETE.16.THE RECEIVING WATER IS FAIRFOREST CREEK. 17.THE EXISTING SOILS ARE CECIL-URBAN LAND COMPLEX, 10 TO 25 PERCENT SLOPES (CuE2), AND URBAN LAND-CECIL COMPLEX, 2 TO 10 PERCENT SLOPES (UcC).18.THE COMPUTER MODEL HYDRAFLOW WAS USED TO DETERMINE THE STORMWATER RUNOFF FOR EACH WATERSHED.19.THE CURRENT OWNER IS PALMETTO OPERATING COMPANY, LLC AND THE NATURE OF CONSTRUCTION IS A COMMERCIAL MIXED-USE REDEVELOPMENT.20.TEMPORARY DIVERSION DITCHES ARE TO BE USED AS NEEDED DURING CONSTRUCTION. THE GRADING CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDINGPOSITIVE DRAINAGE IN ALL INSTANCES.21.ALL SLOPES TO BE STABILIZED BEFORE CITY OF SPARTANBURG FINAL ACCEPTANCE.
SEEDING REQUIREMENTS
BROADCAST SEEDING REQUIREMENTSSEED EVENLY WITH A MECHANICAL SPREADER, RAKEAND/OR CULTI-PACK TO INCORPORATE SEED INTO TOP 2" OFSOIL. ROLL, MULCH WITH THRESHED WHEAT, RYE, BARLEYOR OAT STRAW (WEED FREE) AT A RATE OF 80 LBS/1000 SFAND WATER WITH A FINE SPRAY. APPLY SEED AT THEFOLLOWING RATE PER 1000 SF.- MARCH 1 - SEPTEMBER 300.5-LBS BROWN TOP MILLETIN ADDITION, CHOOSE ONE OF THE FOLLOWING:2-LBS.COMMON BERMUDA (HULLED)3-LBS COMMON BERMUDA (UNHULLED)5-LBS. KENTUCKY 31 TALL FESCUE- OCTOBER 1 - FEBRUARY 28 5-LBS ANNUAL RYE GRASSIN ADDITION, CHOOSE ONE OF THE FOLLOWING:3-LBS COMMON BERMUDA (UNHULLED)5-LBS. KENTUCKY 31 TALL FESCUE10-LBS. 19-19-19 FERTILIZER
CONTRACTOR IS RESPONSIBLE FOR MAINTENANCE OF LAWNS ONLY UNTIL FINAL ACCEPTANCE. IF OWNER FAILS TO PROVIDEADEQUATE WATER AND OTHER MAINTENANCE AFTER FINAL ACCEPTANCE, WARRANTY SHALL BE VOIDED. IT SHALL BE THECONTRACTORS RESPONSIBILITY TO PROVIDE PROOF OF NEGLIGENCE BY THE OWNER.CONTRACTOR SHALL MAINTAIN LAWNS BY WATERING, FERTILIZING, WEEDING, MOWING, TRIMMING, EDGING, AND CONTROLLINGINSECTS AND DISEASE, AS WELL AS ROLLING, REGRADING, AND REPLANTING WHERE REQUIRED TO ESTABLISH A SMOOTH,ACCEPTABLE LAWN FREE OF ERODED AND BARE AREAS. PROVIDE MAINTENANCE UNTIL FINAL ACCEPTANCE.AREAS TO BE BROADCAST SEEDED1. EASEMENT AREAS (EXCLUDING POND EASEMENTS AND EASEMENTS SUBJECT TO CONCENTRATED RUNOFF)2. ALL ROAD SHOULDERS FROM BACK OF CURB TO CLEARING LIMITS3. ANY OTHER AREAS DISTURBED BY THE CONSTRUCTION PROCESSAREAS TO BE HYDROSEEDED1. ALL POND BANKS AND ADJACENT EASEMENT AREAS.2. ANY AREA SUBJECT TO CONCENTRATED RUNOFF.HYDROSEEDING RATESAPPLY SEED, FERTILIZER, AND MULCH AT THE FOLLOWINGRATE PER 1000 SF.- MARCH 1 - SEPTEMBER 300.5-LBS BROWN TOP MILLETIN ADDITION, CHOOSE ONE OF THE FOLLOWING:2-LBS. HULLED SAHARA BERMUDA3-LBS UNHULLED SAHARA BERMUDA5-LBS. REBEL IV TALL FESCUE- OCTOBER 1 - FEBRUARY 28 5-LBS ANNUAL RYE GRASSIN ADDITION, CHOOSE ONE OF THE FOLLOWING:3-LBS UNHULLED SAHARA BERMUDA5-LBS. REBEL IV TALL FESCUE10-LBS. 19-19-19 FERTILIZER50-LBS. 100% WOOD MULCH WITH TRACKIFIERWARRANTY / MAINTENANCEFOR MECHANICALLY SEEDED AND HYDROSEEDED AREAS, THECONTRACTOR SHALL GUARANTEE THAT 97% OF GRASSPLANTED (OF PERMANENT GRASS SPECIES INDICATED) HASGERMINATED AND IS VIGOROUSLY GROWING AT THE TIME OFFINAL INSPECTIONS AND AT FINAL ACCEPTANCE BY THEAPPROPRIATE PARTY.Know what'sbelow.before you dig.Call
R
SURVEY AS-BUILT, PREPARED BY A SC REGISTERED LAND SURVEYOR, AND SHOWING STORM DRAINAGE SYSTEM, PERMANENTSWALES, UTILITIES, BUILDING SLAB LOCATION(S), AND FINISHED FLOOR ELEVATION(S) WILL BE REQUIRED AS PART OF THE CLOSEOUTPROCESS. IT IS THE CONTRACTOR'S REDPONSIBILITY TO PROVIDE THE AS-BUILT SURVEY TO THE ENGINEER AT THE COMPLETION OF CONSTRUCTION.I HAVE PLACED MY SIGNATURE AND SEAL ON THE DESIGN DOCUMENTS SUBMITTED SIGNIFYING THAT I ACCEPT RESPONSIBILITYFOR THE DESIGN OF THE SYSTEM. FURTHER, I CERTIFY TO THE BEST OF MY KNOWLEDGE AND BELIEF THAT THE DESIGN IS CONSISTENT WITH THE REQUIREMENTS OF TITLE 48, CHAPTER 14 OF THE CODES OF LAWS OF SC, 1976 AS AMENDED, PURSUANTTO REGULATION 72-300 ET SEQ. (IF APPLICABLE), AND IN ACCORDANCE WITH THE TERMS AND CONDITIONS OF SCR100000.
CONTRACTOR IS RESPONSIBLE FOR PREPARATION, INSTALLATION, ANDMAINTENANCE OF TRAFFIC CONTROL PLAN & DEVICES
PERMANENT SEEDING - UPSTATEBAHIA GRASS (ALONE)LBS./AC.JANFEBMARAPRMAYJUNJULAUGSEPOCTNOVDEC BAHIA GRASS (MIX)BERMUDA GRASS (HULLED) (ALONE)BERMUDA GRASS (HULLED) (MIX)SPECIES
FESCUE, TALL (KY31) ALONEFESCUE, TALL (KY31) MIXSERICEA LESPEDEZA (SCARIFIED)ALONE OR MIX (INOCULATE WITH ELINNOCULANT)LADINO CLOVER (MIX ONLY)INNOCULATE WITH AB INNOCULANTFOR STEEP SLOPES / CUT SLOPESWEEPING LOVEGRASS (ALONE)WEEPING LOVEGRASS (MIX)CROWNVETCH (MIX) (INOCULATEWITH TYPE M INNOCULANT)
TEMPORARY SEEDING - UPSTATELBS./AC.JANFEBMARAPRMAYJUNJULAUGSEPOCTNOVDEC SPECIESBROWNSTONE MILLET (ALONE)BROWNTOP MILLET (MIX)RYE GRAIN (ALONE)RYE GRAIN (MIX)RYE GRASS (ALONE)RYE GRASS (MIX)FOR STEEP SLOPES / CUT SLOPESWEEPING LOVEGRASS (ALONE)WEEPING LOVEGRASS (MIX)40308-124-64020402428-10
4010561050842
1.IF NECESSARY, SLOPES, WHICH EXCEED EIGHT (8) VERTICAL FEET SHOULD BE STABILIZED WITH SYNTHETIC OR VEGETATIVE MATS, INADDITION TO HYDROSEEDING. IT MAY BE NECESSARY TO INSTALL TEMPORARY SLOPE DRAINS DURING CONSTRUCTION. TEMPORARYBERMS MAY BE NEEDED UNTIL THE SLOPE IS BROUGHT TO GRADE.2.STABILIZATION MEASURES SHALL BE INITIATED AS SOON AS PRACTICABLE IN PORTIONS OF THE SITE WHERE CONSTRUCTIONACTIVITIES HAVE TEMPORARILY OR PERMANENTLY CEASED, BUT IN NO CASE MORE THAN FOURTEEN (14) DAYS AFTER WORK HASCEASED, EXCEPT AS STATED BELOW.WHERE STABILIZATION BY THE 14TH DAY IS PRECLUDED BY SNOW COVER OR FROZEN GROUND CONDITIONS STABILIZATIONMEASURES MUST BE INITIATED AS SOON AS PRACTICABLE.WHERE CONSTRUCTION ACTIVITY ON A PORTION OF THE SITE IS TEMPORARILY CEASED, AND EARTH-DISTURBING ACTIVITIES WILL BERESUMED WITHIN 14 DAYS, TEMPORARY STABILIZATION MEASURES DO NOT HAVE TO BE INITIATED ON THAT PORTION OF THE SITE.3.ALL SEDIMENT AND EROSION CONTROL DEVICES SHALL BE INSPECTED ONCE EVERY CALENDAR WEEK. IF PERIODIC INSPECTION OROTHER INFORMATION INDICATES THAT A BMP HAS BEEN INAPPROPRIATELY, OR INCORRECTLY CONSTRUCTED, THE PERMITTEE MUSTADDRESS THE NECESSARY REPLACEMENT OR MODIFICATION REQUIRED TO CORRECT THE BMP WITHIN 48 HOURS OF IDENTIFICATION.4.PROVIDE SILT FENCE AND/OR OTHER CONTROL DEVICES, AS MAY BE REQUIRED, TO CONTROL SOIL EROSION DURING UTILITYCONSTRUCTION. ALL DISTURBED AREAS SHALL BE CLEANED, GRADED, AND STABILIZED WITH GRASSING IMMEDIATELY AFTER THEUTILITY INSTALLATION. FILL, COVER, AND TEMPORARY SEEDING AT THE END OF EACH DAY ARE RECOMMENDED. IF WATER ISENCOUNTERED WHILE TRENCHING, THE WATER SHOULD BE FILTERED TO REMOVE ANY SEDIMENTS BEFORE BEING PUMPED BACK INTOANY WATERS OF THE STATE.5.ALL EROSION CONTROL DEVICES SHALL BE PROPERLY MAINTAINED DURING ALL PHASES OF CONSTRUCTION UNTIL THE COMPLETIONOF ALL CONSTRUCTION ACTIVITIES AND ALL DISTURBED AREAS HAVE BEEN STABILIZED. ADDITIONAL CONTROL DEVICES MAY BEREQUIRED DURING CONSTRUCTION IN ORDER TO CONTROL EROSION AND/OR OFFSITE SEDIMENTATION. ALL TEMPORARY CONTROLDEVICES SHALL BE REMOVED ONCE CONSTRUCTION IS COMPLETE AND THE SITE IS STABILIZED.6.THE CONTRACTOR MUST TAKE NECESSARY ACTION TO MINIMIZE THE TRACKING OF MUD ONTO PAVED ROADWAY(S) FROMCONSTRUCTION AREAS AND THE GENERATION OF DUST. THE CONTRACTOR SHALL DAILY REMOVE MUD/SOIL FROM PAVEMENT, AS MAYBE REQUIRED.7.RESIDENTIAL SUBDIVISIONS REQUIRE EROSION CONTROL FEATURES FOR INFRASTRUCTURE AS WELL AS FOR INDIVIDUAL LOTCONSTRUCTION. INDIVIDUAL PROPERTY OWNERS SHALL FOLLOW THESE PLANS DURING CONSTRUCTION OR OBTAIN APPROVAL OF ANINDIVIDUAL PLAN IN ACCORDANCE WITH S.C REG. 72-300 ET SEQ. AND SCR100000.8.TEMPORARY DIVERSION BERMS AND/OR DITCHES WILL BE PROVIDED AS NEEDED DURING CONSTRUCTION TO PROTECT WORK AREASFROM UPSLOPE RUNOFF AND/OR TO DIVERT SEDIMENT-LADEN WATER TO APPROPRIATE TRAPS OR STABLE OUTLETS.9.ALL WATERS OF THE STATE (WOS), INCLUDING WETLANDS, ARE TO BE FLAGGED OR OTHERWISE CLEARLY MARKED IN THE FIELD. ADOUBLE ROW OF SILT FENCE IS TO BE INSTALLED IN ALL AREAS WHERE A 50-FOOT BUFFER CAN'T BE MAINTAINED BETWEEN THEDISTURBED AREA AND ALL WOS. A 10-FOOT BUFFER SHOULD BE MAINTAINED BETWEEN THE LAST ROW OF SILT FENCE AND ALL WOS.10.LITTER, CONSTRUCTION DEBRIS, OILS, FUELS, AND BUILDING PRODUCTS WITH SIGNIFICANT POTENTIAL FOR IMPACT (SUCH ASSTOCKPILES OF FRESHLY TREATED LUMBER) AND CONSTRUCTION CHEMICALS THAT COULD BE EXPOSED TO STORM WATER MUST BEPREVENTED FROM BECOMING A POLLUTANT SOURCE IN STORM WATER DISCHARGES.11.A COPY OF THE SWPPP, INSPECTION RECORDS, AND RAINFALL DATA MUST BE RETAINED AT THE CONSTRUCTION SITE OR A NEARBYLOCATION EASILY ACCESSIBLE DURING NORMAL BUSINESS HOURS, FROM THE DATE OF COMMENCEMENT OF CONSTRUCTIONACTIVITIES TO THE DATE THAT FINAL STABILIZATION IS REACHED.12.INITIATE STABILIZATION MEASURES ON ANY EXPOSED STEEP SLOPE (3H:1V OR GREATER) WHERE LAND-DISTURBING ACTIVITIES HAVEPERMANENTLY OR TEMPORARILY CEASED, AND WILL NOT RESUME FOR A PERIOD OF 7 CALENDAR DAYS.13.MINIMIZE SOIL COMPACTION AND, UNLESS INFEASIBLE, PRESERVE TOPSOIL.14.MINIMIZE THE DISCHARGE OF POLLUTANTS FROM EQUIPMENT AND VEHICLE WASHING, WHEEL WASH WATER, AND OTHER WASHWATERS. WASH WATERS MUST BE TREATED IN A SEDIMENT BASIN OR ALTERNATIVE CONTROL THAT PROVIDES EQUIVALENT OR BETTERTREATMENT PRIOR TO DISCHARGE;15.MINIMIZE THE DISCHARGE OF POLLUTANTS FROM DEWATERING OF TRENCHES AND EXCAVATED AREAS. THESE DISCHARGES ARE TO BEROUTED THROUGH APPROPRIATE BMPS (SEDIMENT BASIN, FILTER BAG, ETC.).16.THE FOLLOWING DISCHARGES FROM SITES ARE PROHIBITED: WASTEWATER FROM WASHOUT OF CONCRETE, UNLESS MANAGED BY AN APPROPRIATE CONTROL; WASTEWATER FROM WASHOUT AND CLEANOUT OF STUCCO, PAINT, FORM RELEASE OILS, CURING COMPOUNDS AND OTHER CONSTRUCTION MATERIALS; FUELS, OILS, OR OTHER POLLUTANTS USED IN VEHICLE AND EQUIPMENT OPERATION AND MAINTENANCE; ANDSOAPS OR SOLVENTS USED IN VEHICLE AND EQUIPMENT WASHING.17.AFTER CONSTRUCTION ACTIVITIES BEGIN, INSPECTIONS MUST BE CONDUCTED AT A MINIMUM OF AT LEAST ONCE EVERY CALENDARWEEK AND MUST BE CONDUCTED UNTIL FINAL STABILIZATION IS REACHED ON ALL AREAS OF THE CONSTRUCTION SITE.18.IF EXISTING BMPS NEED TO BE MODIFIED OR IF ADDITIONAL BMPS ARE NECESSARY TO COMPLY WITH THE REQUIREMENTS OF THISPERMIT AND/OR SC'S WATER QUALITY STANDARDS, IMPLEMENTATION MUST BE COMPLETED BEFORE THE NEXT STORM EVENTWHENEVER PRACTICABLE. IF IMPLEMENTATION BEFORE THE NEXT STORM EVENT IS IMPRACTICABLE, THE SITUATION MUST BEDOCUMENTED IN THE SWPPP AND ALTERNATIVE BMPS MUST BE IMPLEMENTED AS SOON AS REASONABLY POSSIBLE.19.A PRE-CONSTRUCTION CONFERENCE MUST BE HELD FOR EACH CONSTRUCTION SITE WITH AN APPROVED ON-SITE SWPPP PRIOR TOTHE IMPLEMENTATION OF CONSTRUCTION ACTIVITIES. FOR NON-LINEAR PROJECTS THAT DISTURB 10 ACRES OR MORE THISCONFERENCE MUST BE HELD ON-SITE UNLESS CITY OF SPARTANBURG HAS APPROVED OTHERWISE.20.CONTRACTORS ARE REQUIRED TO HAVE RAIN GAUGES AT THE CONSTRUCTION SITE AND THE RAIN TOTALS DOCUMENTED FOR REVIEWBY CITY OF SPARTANBURG AND SCDHEC.21.A PRE-CONSTRUCTION CONFERENCE MUST BE HELD WITH THE CITY OF SPARTANBURG AT LEAST 48 HOURS PRIOR TO BEGINNING ANYLAND DISTURBING ACTIVITIES. THE OWNER, DESIGN ENGINEER AND CONTRACTOR MUST BE PRESENT AND HAVE OBTAINED THESTORMWATER PERMIT, STAMPED APPROVED PLANS AND THE N.O.I APPROVAL LETTER FROM SCDHEC BEFORE CALLING CITY OFSPARTANBURG AT (864) 596-2089 TO SCHEDULE THIS MEETING.
CITY OF SPARTANBURG STANDARD NOTESOBJECTS AND SYMBOLSBenchmarkSanitary Sewer ManholeSanitary Sewer Manhole ID #Sanitary Sewer CleanoutDouble Sanitary Sewer Service (Residential Only)Single Sanitary Sewer Service (Residential Only)TYPE 16 Storm Drainage Structure (CI-16)
Storm Drainage Structure ID #Telephone BoxTelephone ManholeElectrical BoxElectrical ManholePower PoleLight PoleFire Hydrant AssemblyWater Line ValveWater Line ReducerSingle Water Service (Residential Only)Double Water Service (Residential Only)
Water Blowoff
SignADA Accessible Parking SpaceSpot ElevationDrainage Basin AreaRevision ID #Parking Count ID #Lot #
EXISTINGNEWN/AN/A
N/AN/AN/AN/AN/A
N/AN/AN/AN/AX.XX
MH
Ac
CS
TTEE
KeynoteN/A
YI
TYPE 17 Storm Drainage Structure (Right) (CI-17)TYPE 17 Storm Drainage Structure (Left) (CI-17)TYPE 18 Storm Drainage Structure(CI-18)Catch Basin (CB)Isolation Box (IB)Storm Drainage Junction Box (JB)Yard Inlet (YI)
OBJECTS AND SYMBOLSAdjoining Property LineCenterlineEasementSetbackSanitary Sewer (Gravity)Sanitary Sewer (Force Main)Water LineCurb & Gutter (Straight)
(Same as Existing)(Same as Existing)
Curb & Gutter (Roll)Previous Phase Storm Drain PipeRoof DrainSubsurface DrainageSilt Fence, StandardSilt Fence, ReinforcedPhase LineDrainage Basin LimitsFlood ZoneConduitNatural GasOverhead ElectricalUnderground ElectricalUnderground TelephoneUnderground Cable
N/AN/A
Underground Fiber OpticFenceElevation ContourRevision Cloud (Encloses Revision)N/A
N/AWater Line Bends, Angle Varies
DRAWING LEGEND22
22
EXISTINGNEW
TYPE 1 Storm Drainage Structure (CI-1)N/A
N/A
X.XX
#
ZONE 'X'ZONE 'AE'
Rip Rap at Pipe OutletN/A
YICSControl Structure (CS)CSIBIB Storm Drain Pipe(Width varies with size)(Width varies with size)N/AN/ADrainage Flow Arrow
Right of WayLot Line
6X.XX121441
#
720720725730735740745750
755
705710715720
735740
735
740735740745750
740745750755760765770
730735740745750755760765
735735740740
745750755
725730735740745
730735740745750755
740
745750755760
755760
730735740745750
720725730735720725730
735
735740
740745
745
750
750
725
725
730
735
720725725
725730735740745
725730735740745750
720 725730715
735
725730
715720725730735 725730735
725
730
735730725720
723
723
733
S
S
S
S
DD
D
DD
D
N 66° 01' 57" E86.48'S 23° 43' 22" E53.04'S 66° 02' 28" W84.95'N 25° 23' 31" W38.36'
S 21° 07' 12" E(TIE) 21.53'
S 57° 15' 36" E46.10'
S 65° 44' 37" W 357.56'
N 39° 43' 46" W 163.66'
N 24° 02' 40" W 360.16'
N 06° 37' 36" W67.42'
N 36° 10' 34" W 161.91'S 32° 41' 58" W62.58'
N 69° 44' 16" W103.08'
N 25° 46' 14" W 94.96'N 25° 39' 52" W 99.96'N 25° 32' 43" W49.91'N 25° 32' 12" W49.88'N 26° 02' 01" W29.94'
S 67° 46' 25" W82.66'N 03° 34' 47" E85.11'N 03° 49' 21" E45.18'N 08° 16' 19" E84.75'L1L2
S 57° 45' 15" E 205.48'
L3L4S 56° 49' 57" E 143.66'
S 57° 48' 23" E 125.24'
S 80° 26' 14" E 274.87'
L5
S 25° 46' 10" E 569.69'
S 17° 35' 34" E132.25'
WGSO
GE
W
DD
G
S
1" CT3/4" CT-BENT3/4" OT-BENT
742.1CEDAR STREET15' R/W WIDTH PER PB 2PG 72UNIMPROVED
AREA OFUNCERTANTYNON-ORGANICDEBRIS
GATE
GATEMOTORIZEDGATEGATE
S
S
#4 RBIN 3" PIPE
#4 RBIN 3" PIPE
2" BOLT1-1/2" OT2" DISKIN 3" PIPE
#4 RB#4 RB
#4 RB1" CT1/2" CT#4 RB
#4 RBIN 2" PIPE2" CT1" CT
3/4" CT-BENT#4 RB
3/4" OT
#4 RB
D
~CONCRETE~~CONCRETE~RAMP
N 31° 00' 50" E 224.59OLD LOT LINE - TO BE ABANDONED
4.4'0.8'42.1'21.1'25.0'73.4'89.2'118.9'35.4'20.4'1.3'
33.6'26.0'82.0'84.7'121.7'16.1'34.4'
31.8'119.9'
50.1'69.8'
76.6
3.03.3
72.3
15.6
S
3 STORYBRICK BUILDING31,260 SF
WAREHOUSE3,811 SF
TMS: 7-12-13-024.00 &7-12-13-001.00TO BE COMBINED AND MADEA SINGLE PARCELTOTAL AREA:430,963 SF9.89 ACRES
60" OAK
PILGRIM STROAD NOT CONSTRUCTED20' R/W PER PB 180 PG 123
RICE ST25' R/W PER PB 180 PG 123
MONK STR/W UNKNOWN
OXFORD RD50' R/W PER PB 175 PG 56
PENOLA ST30' R/W PERPB 92 PG 75NOTIMPROVED
W MAIN STSC HWY 2975' R/W PER PB 175 PG 56
N/F: MARSHALL CLARK ET ALTMS: 7-12-13-048.00DB 127-M PG 659PB 2 PG 71-72
N/F: DEBORAH HOLMESTMS: 7-12-09-156.00DB 132-C PG 276N/F: VICTOR JOSEPHTMS: 7-12-09-190.00DB 115-N PG 644PB 51 PG 664
N/F: CITY OF SPARTANBURGTMS: 7-12-09-200.00DB 101-R PG 762
N/F: THE BANKS LAW FIRM PATMS: 7-12-13-051.00DB 129-V PG 870
N/F: STEPHEN WASHINGTONTMS: 7-12-13-042.00DB 122-L PG 874
N/F: CAROLINA INS& INVESTMENT COTMS: 7-12-13-041.00DB 33-D PG 495
N/F: KAPASI INVESTMENTS, LLCTMS: 7-12-13-040.00DB 93-Q PG 778PB 165 PG 738
N/F: JAMES & LYNN FLYNNTMS: 7-12-13-035.00DB 75-U PG 533PB 177 PG 568
N/F: NEW LIFE MINISTRIESCHURCH OF SPARTANBURGTMS: 7-12-13-038.00DB 70-T PG 575PB 29 PG 52
N/F: SPANN VENTURES LLCTMS: 7-12-13-037.00DB 124-A 569PB 10 PG 100
N/F: CAPA REAL ESTATE LLCTMS: 7-12-13-005.00DB 132-K PG 598PB 151 PG 360
N/F: EARLE CLOWNEY ETALTMS: 7-12-13-004.00DB 64-U PG 668
N/F: MOLLY UZORTMS: 7-12-13-003.00DB 89-R PG 634PB 134 PG 811N/F: DAX PROPERTIES LLCTMS: 7-12-13-002.01DB 133-L PG 1PB 92 PG 75N/F: DAX PROPERTIES LLCTMS: 7-12-13-002.00DB 133-L PG 1PB 92 PG 75
N/F: ETHAN FLOYDTMS: 7-11-12-313.00DB 132-C PG 708PB 135 PG 66
N/F: LAW PETERTMS: 7-11-12-312.00DB 114-X PG 845PB 130 PG 202
N/F: JOSEPHWILKES,DAVID MEADOR& MCKINLEYWILKESTMS: 7-11-12-311.00DB 139-H PG 329PB 130 PG 202
N/F: MARSHALL CLARK ET ALTMS: 7-12-13-047.00DB 127-M PG 659PB 2 PG 71-72
N/F: JBURKE INVESTMENTS LLCTMS: 7-12-13-020.00DB 124-Z PG 405PB 25-266
UPLANDDRAINAGEFEATURE
INTERMITTENTSTREAM 1 (CONT.)
PERENNIALSTREAM 1(CONT.)
PERENNIAL STREAM 1899 LF0.12 ACRES
SINTERMITTENTSTREAM 1105 LF
CONC.RAMP
~ASPHALT~
~ASPHALT~
~ASPHALT~
~DILAPIDATEDASPHALT~
~CONCRETE~
~ASPHALT~
36.2'25.0'36.2'25.0'53.77.3
DOCK CURB
14' OVERHANG
TWO DIRECTIONBILLBOARD
FFE: 735.4
CO
COVERED DOCK
18" CONCRETECURB/GUTTER
MW
~CONCRETEDOCK~
752.1752.1
734.1726.3
747.7745.8739.9
722.7
712.6
721.0725.1
741.7
730.3
723.9724.0
708.8711.7703.3704.8
711.1721.9721.9
721.7
~ASPHALT~
ELEVATED PAD
1" SR-BENT
FFE: 735.5
~ASPHALT~
~CONCRETE~WAREHOUSE##### SFCONC.RAMP
EAS BENCHMARKMAG NAILS.C. SPCS (NAD83/NAVD88)N: 1,133,562.59E: 1,716,867.79EL: 726.2EAS BENCHMARKMAG NAILS.C. SPCS (NAD83/NAVD88)N: 1,133,791.34E: 1,716,717.27EL: 722.1
FFE: 725.5
FFE: 725.3
FFE: 725.1
FFE: 722.7
FFE: 722.7
FFE: 724.8FFE: 724.7FFE: 724.8
S
61.5'
DC2.0OVERALLEXISTINGCONDITIONS H05/04/2302/16/23BC02/21/23D03/27/23 F04/12/23G04/27/2305/17/23IJ06/02/23 SCALE: 1" = 60'30601200SEWN
COPYRIGHT c SEAMON, WHITESIDE & ASSOCIATES, INC.THIS DRAWING SHALL NOT BE REPRODUCED IN ANY MANNER OR USED FOR ANY PURPOSE WITHOUT WRITTEN PERMISSION.
GR4714DBLM/CS10/14/22DATE:
501 WANDO PARK BOULEVARD, SUITE 200 | MOUNT PLEASANT, SC 29464 | 508 RHETT STREET, SUITE 101 | GREENVILLE, SC 29601
500 W MAIN STCITY OF SPARTANBURG, SOUTH CAROLINACOKE FACILITYREDEVELOPMENT PHASE 1REVISION HISTORYDRAWN BY:CHECKED BY:SW+ PROJECT:
MOUNT PLEASANT, SC843.884.1667GREENVILLE, SC864.298.0534
WWW.SEAMONWHITESIDE.COMSUMMERVILLE, SC843.972.0710SPARTANBURG, SC864.272.1272CHARLOTTE, NC980.312.54506/1/23
REFERENCE SHEET C2.2 FOR DEMOLITION PLAN.
R
Know what'sbelow.before you dig.Call
SURVEY NOTE:BOUNDARY AND ALL ELEVATIONS ARE BASED ON THE TOPOGRAPHIC SURVEYCOMPLETED BY EAS PROFESSIONALS, INC. (DATED DECEMBER 16, 2022). THE SURVEY IS BASED OFF OF NAD83 VERTICAL DATUM, AND BEARINGS AREREFERENCED TO THE SOUTH CAROLINA STATE PLANE COORDINATE SYSTEM.
DIMENSIONS ON THIS SHEET ARE SURVEYED(NOT CALCULATED) MEASUREMENTS.
EXISTING UTILITY NOTE:THE LOCATION OF EXISTING UNDERGROUND UTILITIES ARESHOWN IN AN APPROXIMATE WAY ONLY AND HAVE NOT BEENINDEPENDENTLY VERIFIED BY THE OWNER OR ITSREPRESENTATIVE. THE CONTRACTOR SHALL DETERMINE THEEXACT LOCATION OF ALL EXISTING UTILITIES BEFORECOMMENCING ANY WORK, AND AGREES TO BE FULLYRESPONSIBLE FOR ANY AND ALL DAMAGES WHICH MIGHTOCCUR DUE TO THE CONTRACTOR'S FAILURE TO EXACTLYLOCATE AND PRESERVE ANY AND ALL UNDERGROUND UTILITIES.
720720725
705710715720
735
740730735740
720725730
735
720725730
735
735740
740
745
745
750
750
725725 730 735
720
725
725
725730735
740
745725730735740745
720
725
730
715
735725730
715720725730735
725730735
725
730
720
723723 733S
S SS
D
D
D DD
D
N 66° 01' 57" E86.48'S 23° 43' 22" E53.04'S 66° 02' 28" W84.95'N 25° 23' 31" W38.36'
S 57° 15' 36" E46.10'
S 65° 44' 37" W 357.56'
N 39° 43' 46" W 163.66'
N 24° 02' 40" W 360.16'
N 06° 37' 36" W67.42'
N 36° 10' 34" W 161.91'S 32° 41' 58" W62.58'N 69° 44' 16" W103.08' L5
S 25° 46' 10" E 569.69'
S 17° 35' 34" E132.25'
HYDWSO
WSO
WSOWWSOWSOWSOWSOHYDGSO
WSOHYD
GE
W
DD
G
S
SEE NOTE #22
TMS: 7-12-13-024.00DB 130K PG 599PB 175 PG 56AREA: 320,931.2 SF7.37 ACRES742.1AREA: 4,545 SFOR 0.10 OF AN ACRE
N/F OXFORD ROAD RIGHT-OF-WAYSEE NOTE #22
6" VCP EXPOSED
GATE
GATE
MOTORIZEDGATE
GATE
S
#4 RBIN 3" PIPE
#4 RBIN 3" PIPE
2" BOLT
1-1/2" OT2" DISKIN 3" PIPE
#4 RB#4 RB #4 RB1" OT-BENT
3/4" OT
#4 RB
ABCDE
D
~CONCRETE~
~CONCRETE~
RAMP
4.4'0.8'42.1'21.1'25.0'73.4'89.2'118.9'
35.4'20.4'1.3'33.6'26.0'82.0'84.7'
121.7'
16.1'34.4'
31.8'
119.9' 50.1'69.8'76.6
3.0
3.3
72.3
15.6
3 STORYBRICK BUILDING31,260 SF
WAREHOUSE3,811 SF
MONK STR/W UNKNOWN
OXFORD RD50' R/W PER PB 175 PG 56
W MAIN STSC HWY 2975' R/W PER PB 175 PG 56CATCH BASINRIM:725.518" RCP INV:719.9SDMHRIM:722.46" VCP INV (A):717.918" RCP INV (B):716.6
36" RCPINV:702.436" RCPINV:702.424" RCPINV:704.5
24" HDPE INV:715.1
GRATE INLETRIM:721.224" HDPE INV:
36" RCP INV:710.0SDMHRIM:721.318" RCP INV (A):716.318" RCP INV (B):716.2
18" RCPINV:716.3CATCH BASINRIM:722.118" RCP INV:717.4
36" RCPIE:717.6
GRATE INLETRIM:724.330" RCP INV (A):720.530" RCP INV (B):720.1
30: RCPINV:717.130" RCPINV:712.5
GRATE INLETRIM:734.38" RCP INV:GRATE INLETRIM:720.230" RCP INV (A):707.18" VCP INV (B):716.812" VCP INV (C):709.830" RCP INV (D):707.1
SSMHRIM:723.08" VCP INV (A):716.36" VCP INV (B):719.06" VCP INV (C):716.48" VCP INV (D):716.26" VCP INV (E):718.0
SDMHRIM:724.336" RCP INV (A):716.342" RCP INV (B):699.142" RCP INV (C):699.2
SSMHRIM:724.512" VCP INV (A):703.815" VCP INV (B):700.915" VCP INV (C):701.1SSMHRIM:723.58" VCP INV (A):718.412" VCP INV (B):717.812" VCP INV (C):717.7
SSMHRIM:721.912" VCP INV (A):711.312" VCP INV (B):711.2
CATCH BASINRIM:733.818" RCP INV:728.6
GRATE INLETRIM:734.46"PVC INV(A): 733.26"VCP INV(B): 732.3
24" RCPIE: 718.46" VCPIE: 720.56" VCPIE: 720.0
SSMHRIM:727.2SEE NOTE 20SSMHRIM:724.0SEE NOTE 20
GRATE INLETRIM:719.710" RCP INV:717.5
N/F: MARSHALL CLARK ET ALTMS: 7-12-13-048.00DB 127-M PG 659PB 2 PG 71-72
N/F: STEPHEN WASHINGTONTMS: 7-12-13-042.00DB 122-L PG 874
N/F: CAROLINA INS& INVESTMENT COTMS: 7-12-13-041.00DB 33-D PG 495
N/F: KAPASI INVESTMENTS, LLCTMS: 7-12-13-040.00DB 93-Q PG 778PB 165 PG 738N/F: JAMES & LYNN FLYNNTMS: 7-12-13-035.00DB 75-U PG 533PB 177 PG 568
N/F: NEW LIFE MINISTRIESCHURCH OF SPARTANBURGTMS: 7-12-13-038.00DB 70-T PG 575PB 29 PG 52
N/F: SPANN VENTURES LLCTMS: 7-12-13-037.00DB 124-A 569PB 10 PG 100
N/F: MARSHALL CLARK ET ALTMS: 7-12-13-047.00DB 127-M PG 659PB 2 PG 71-72
N/F: JBURKE INVESTMENTS LLCTMS: 7-12-13-020.00DB 124-Z PG 405PB 25-266
UPLANDDRAINAGEFEATURE
INTERMITTENTSTREAM 1 (CONT.)
PERENNIALSTREAM 1(CONT.) SSSMHRIM: 728.0IE(A): 719.7IE(B): 719.6
INTERMITTENTSTREAM 1105 LF
CONC. RAMP
~ASPHALT~ ~ASPHALT~
~ASPHALT~
~DILAPIDATEDASPHALT~~CONCRETE~
30" RCPIE: 722.1
GRATE INLETRIM:721.96" VCP INV (A):717.96" VCP INV (B):717.8
~ASPHALT~REMAINS OFCONCRETEBUILDING PAD
36.2'25.0'36.2'25.0'53.77.3
DOCK CURB
GRATE INLETRIM:734.66" VCP INV (A):730.66" VCP INV (B):730.514' OVERHANG
6" WIDE RET. WALL
15'x26' OVERHANGWITH LOADING DOCK
CATCH BASIN10" RCP INV:717.2APPROX. LOCATION(SEE NOTE #21)
TWO DIRECTIONBILLBOARDFFE: 735.4
A/C ONCONC. PAD
CO
SUMP4"DIP TOP: 724.4 IN 12" VCP,ALSO RECEIVES 6" RDC
COVERED DOCK
WMHOOKUP18" CONCRETECURB/GUTTER
6" PVC,INV:721.06" VCP,INV:714.76" PVC,INV:720.9MW
MDMDDMD
DMD
MD
MDA/C ONCONC. PADMD
MD
MD
RD
~CONCRETE DOCK~CONCRETE RETAINING WALL
CONCRETE PADS
752.1752.1
734.1
747.7745.8
739.9722.7
712.6
721.0
725.1
741.7
730.3
723.9724.0
708.8711.7703.3
704.8
711.1
721.9721.9
721.7
~ASPHALT~
ELEVATED PAD
8' HIGH CHAINLINK FENCE8' HIGH CHAINLINK FENCE8' HIGH CHAINLINK FENCE
8' HIGH CHAINLINK FENCE
8' HIGH CHAINLINK FENCE8' HIGH CHAINLINK FENCE
16' OF 1' WIDESLOT DRAININV: 725.0 DISCHARGESTO GRADE
CONC.HEADWALL 1" SR-BENT
CONCRETESPILL POND
RD
RDRD
18" CONCRETECURB/GUTTER
RD
6" PVC DRAINAGEALONG WALL
1 1/2' WIDERETAINING WALL1' WIDERETAINING WALL
FFE: 735.5
8' HIGH CHAINLINK FENCE
8' HIGH CHAINLINK FENCE
8' HIGH CHAINLINK FENCE
8' HIGH CHAINLINK FENCEELEVATEDCONC. CURB
CONC. CURB
MD
EPEP
RD
8" WIDE RET. WALL
RET. WALL
6" CONC. CURB
INACCESSIBLE10'x20' OVERHANG13.8'WIDE16.3'WIDE7.2'WIDE
8.0'WIDE
1' WIDERETAINING WALLWITH FENCE
13.8'WIDE13.8'W DOOR
6'WIDE6'WIDE
12.0'WIDE
MD11.8'WIDE
15.8'WIDEMD
MD METALCABINET
~ASPHALT~
BLOCK PILLAR
AB
AB
AB
AB
ABD
CAB
A ABC BC
AB
8" WALL(POOR CONDITION)
REMAINS OFCONCRETEBELOW GRADE
MAN GATE
APPROX. LOCATIONSHOWN ONPB 175, PG 56C
~CONCRETE~
WAREHOUSE##### SF
PER M/O ONLYCONC. RAMP
RDRDRDRD
30" IN THIS AREA NOT FOUND(24" RCP IS AT FULL FLOW AT TIME OF RAIN STORM)
EAS BENCHMARKMAG NAILS.C. SPCS (NAD83/NAVD88)N: 1,133,562.59E: 1,716,867.79EL: 726.2
EAS BENCHMARKMAG NAILS.C. SPCS (NAD83/NAVD88)N: 1,133,791.34E: 1,716,717.27EL: 722.1FFE: 725.5
FFE: 725.3
FFE: 725.1
FFE: 722.7FFE: 722.7
FFE: 724.8FFE: 724.7
FFE: 724.8
ABAPPARENT SINKHOLE(NOT PRESENT AT TIME OF ORIGINAL FIELDSURVEY) 9.6' BELOW ASPHALT (12-15-2022)
PER M/O ONLY
61.5'
D
CONCRETE DEBRISALONG THIS SLOPE
RAMP
E
CURB/GUTTERMISSING
50.0
AB
TMS: 7-12-13-024.00DB 130K PG 599PB 175 PG 56AREA: 320,931.2 SF7.37 ACRES
C2.1EXISTINGCONDITIONS 02/16/23B D03/27/23 F04/12/23 05/17/23IJ06/02/23 153060SCALE: 1" = 30'0
SEWN
COPYRIGHT c SEAMON, WHITESIDE & ASSOCIATES, INC.THIS DRAWING SHALL NOT BE REPRODUCED IN ANY MANNER OR USED FOR ANY PURPOSE WITHOUT WRITTEN PERMISSION.
GR4714DBLM/CS10/14/22DATE:
501 WANDO PARK BOULEVARD, SUITE 200 | MOUNT PLEASANT, SC 29464 | 508 RHETT STREET, SUITE 101 | GREENVILLE, SC 29601
500 W MAIN STCITY OF SPARTANBURG, SOUTH CAROLINACOKE FACILITYREDEVELOPMENT PHASE 1REVISION HISTORYDRAWN BY:CHECKED BY:SW+ PROJECT:
MOUNT PLEASANT, SC843.884.1667GREENVILLE, SC864.298.0534
WWW.SEAMONWHITESIDE.COMSUMMERVILLE, SC843.972.0710SPARTANBURG, SC864.272.1272CHARLOTTE, NC980.312.54506/1/23
R
Know what'sbelow.before you dig.Call
EXISTING UTILITY NOTE:THE LOCATION OF EXISTING UNDERGROUND UTILITIES ARESHOWN IN AN APPROXIMATE WAY ONLY AND HAVE NOT BEENINDEPENDENTLY VERIFIED BY THE OWNER OR ITSREPRESENTATIVE. THE CONTRACTOR SHALL DETERMINE THEEXACT LOCATION OF ALL EXISTING UTILITIES BEFORECOMMENCING ANY WORK, AND AGREES TO BE FULLYRESPONSIBLE FOR ANY AND ALL DAMAGES WHICH MIGHTOCCUR DUE TO THE CONTRACTOR'S FAILURE TO EXACTLYLOCATE AND PRESERVE ANY AND ALL UNDERGROUND UTILITIES.
REFERENCE SHEET C2.2 FOR DEMOLITION PLAN.SURVEY NOTE:BOUNDARY AND ALL ELEVATIONS ARE BASED ON THE TOPOGRAPHIC SURVEYCOMPLETED BY EAS PROFESSIONALS, INC. (DATED DECEMBER 16, 2022). THE SURVEY IS BASED OFF OF NAD83 VERTICAL DATUM, AND BEARINGS AREREFERENCED TO THE SOUTH CAROLINA STATE PLANE COORDINATE SYSTEM.
DIMENSIONS ON THIS SHEET ARE SURVEYED(NOT CALCULATED) MEASUREMENTS.
SURVEY NOTE #22:50' OXFORD ROAD RIGHT-OF-WAY SHOWN ON SUBJECT PROPERTY PER DB117-C PG 592 QUITCLAIM DEED. THE DEED STATES: "EXCLUDING HOWEVERANY RIGHT, TITLE OR INTEREST IN AND TO ALL UTILITY EASEMENTS ANDRIGHT OF WAY IN FAVOR OF THE CITY OF SPARTANBURG LYING WITHIN THEAREA HEREIN ABOVE CONVEYED, THE SAID UTILITY EASEMENTS AND RIGHTOF WAY BEING SPECIFICALLY RETAINED BY THE GRANTOR"
720720725
705710715720
735
740730735740
720725730
735
720725730
735
735740
740
745
745
750
750
725725 730 735
720
725
725
725730735
740
745725730735740745
720
725
730
715
735725730
715720725730735
725730735
725
730
720
723723 733S
S SS
D
D
D DD
D
HYDWSO
WSO
WSOWWSOWSOWSOWSOHYDGSO
WSOHYD
GE
W
DD
G
S
S
D
MONK STR/W UNKNOWN
OXFORD RD50' R/W PER PB 175 PG 56
W MAIN STSC HWY 2975' R/W PER PB 175 PG 56
S
~ASPHALT~
CO
MW
~ASPHALT~D E EXISTINGWAREHOUSEBUILDING
EXISTINGWAREHOUSEBUILDINGEXISTING COKE BUILDING
REMOVE EXISTING OVERHEAD POWER LINE(COORDINATE WITH DUKE ENERGY)8' HIGH CHAIN LINK FENCEAND GATE TO BE REMOVED
RETAINING WALLTO BE REMOVED
8' HIGH CHAIN LINK FENCEAND GATES TO BE REMOVED
CONCRETE DEBRIS ALONGSLOPE TO BE REMOVED
TELECOMMUNICATIONS BOXTO BE REMOVEDRETAINING WALL WITHFENCE TO BE REMOVEDMETAL CABINETTO BE REMOVED
RETAINING WALLTO BE REMOVEDSTORM STRUCTURETO BE REMOVED8' HIGH CHAIN LINKFENCE TO BE REMOVED
CONCRETE SPILL PONDTO BE REMOVED
ELEVATED CONCRETE PADTO BE REMOVEDWATER METER HOOKUPTO BE REMOVED8' HIGH CHAIN LINKFENCE AND GATETO BE REMOVED
A/C AND CONCRETE PADTO BE REMOVED
RETAINING WALLTO BE REMOVED
TRENCH DRAINTO BE REMOVED
STORM STRUCTURETO BE REMOVED
STORM STRUCTURETO BE REMOVEDA/C AND CONCRETEPAD TO BE REMOVEDGATE TO BE REMOVEDRETAINING WALLTO BE REMOVED8' HIGH CHAIN LINKFENCE TO BE REMOVED
REMOVE EXISTING OVERHEAD POWER LINE(COORDINATE WITH DUKE ENERGY)
REMOVE EXISTING OVERHEAD POWER LINE(COORDINATE WITH DUKE ENERGY)
EXISTING WATERSERVICE LINE ANDMETER TO BE REMOVED8' HIGH CHAIN LINKFENCE TO BE REMOVED
OVERHANG TO BE REMOVED
REMOVE EXISTING OVERHEADPOWER LINE AND POLES(COORDINATE WITH DUKE ENERGY)
REMOVE EXISTING OVERHEADPOWER LINE AND POLES(COORDINATE WITH DUKE ENERGY)EXISTING GAS LINERELOCATION TO BEFIELD DETERMINED
EXISTING STORM STRUCTURES TOREMAIN. TOP TO BE REMOVED ANDSTRUCTURE COVERED & SEALEDBEFORE PAVEMENT INSTALLATION.
EXISTING STORM STRUCTURES TOREMAIN. TOP TO BE REMOVED ANDSTRUCTURE COVERED & SEALEDBEFORE PAVEMENT INSTALLATION.
EXISTING STORM MANHOLETO REMAIN. ADJUST RIM TOPROPOSED GRADE.
EXISTING STORM DRAIN LINEUNDER BUILDING TO REMAIN
EXISTING STORMDRAIN TO REMAIN
EXISTING STORM INLET TOREMAIN. ADJUST GRATETO PROPOSED GRADE.
EXISTING STORM STRUCTURE TO REMAIN. TOP TO BE REMOVED ANDSTRUCTURE COVERED & SEALED BEFORE PAVEMENT INSTALLATION.STRUCTURE INVERT NOT INCLUDED IN SURVEY. IN CASE OFDISCREPANCIES REPORT INVERT TO ENGINEER IMMEDIATELY.
EXISTING STORM DRAIN LINE ANDSTORM STRUCTURE TO REMAIN
CHAIN LINK FENCETO BE REMOVED
REMOVE EXISTING MONITORING WELLEXISTING ROOFDRAIN COLLECTORTO BE REMOVED
OVERHANG AND CONCRETEDOCK TO BE REMOVED
EXISTING POWER POLE TO REMAIN(COORDINATE WITH DUKE ENERGY)EXISTING HYDRANT TO REMAINREMOVEEXISTINGHYDRANTEXISTING WATER SERVICE LINEAND METER TO BE REMOVEDEXISTING WATER SERVICE LINEAND METER TO BE REMOVEDREMOVE EXISTING WATER VAULTREMOVE EXISTING CONCRETEREMOVE EXISTING OVERHEADPOWER LINE AND POLES(COORDINATE WITH DUKE ENERGY)EXISTING MANHOLE TO REMAINREMOVE EXISTING SEWERMAIN LINE. SEE SEWERPLAN, SHEET C8.1.
EXISTING CONCRETE TO REMAIN
EXISTING GAS LINERELOCATION TO BEFIELD DETERMINED
REMOVE EXISTINGSEWER SERVICE
REMOVE EXISTING SEWER SERVICE
REMOVE EXISTING SEWERMAIN LINE. SEE SEWERPLAN, SHEET C8.1.
REMOVE EXISTING SEWERSTRUCTURE (BURIED)
SANITARY SEWER MANHOLETO REMAIN. SEE SEWERPLAN, SHEET C8.1.
SAWCUT EXISTING ASPHALT FORNEW DRIVEWAY CONNECTION.CONTRACTOR TO ENSURE A SMOOTHTRANSITION TO EXISTING PAVEMENT.
BILLBOARD TO REMAIN, COORDINATEWITH LAMAR ADVERTISING COMPANY
LIMITS OF DISTURBANCE±6.50 ACRES(SEE PHASED EROSIONCONTROL PLANS)
STAIR CASE TO BE REMOVED
EXISTING TEE TOBE CUT-OUT ANDSTRAIGHT-PIPEDPER SWS
EXISTING TEE TOBE CUT-OUT ANDSTRAIGHT-PIPEDPER SWS
REMOVEEXISTINGHYDRANT
50' CONSTRUCTIONBUFFER (TYP.)
50' CONSTRUCTIONBUFFER (TYP.)
50' CONSTRUCTIONBUFFER (TYP.)50' CONSTRUCTIONBUFFER (TYP.)
EXISTING TEE TOBE CUT-OUT ANDSTRAIGHT-PIPEDPER SWS (TYP.)
ENSURE PEDESTRIANS HAVE SIDEWALK ACCESSTHROUGHOUT CONSTRUCTION ACTIVITIES.PROVIDE DETOURS AS NECESSARY TO ENSURENO BLOCKAGE OF PEDESTRIAN TRAFFIC.
ENSURE PEDESTRIANS HAVE SIDEWALK ACCESSTHROUGHOUT CONSTRUCTION ACTIVITIES.PROVIDE DETOURS AS NECESSARY TO ENSURENO BLOCKAGE OF PEDESTRIAN TRAFFIC.
C2.2DEMOLITIONPLAN H05/04/2302/16/23B D03/27/23E03/30/23F04/12/23 05/17/23IJ06/02/23
SEWN
COPYRIGHT c SEAMON, WHITESIDE & ASSOCIATES, INC.THIS DRAWING SHALL NOT BE REPRODUCED IN ANY MANNER OR USED FOR ANY PURPOSE WITHOUT WRITTEN PERMISSION.
GR4714DBLM/CS10/14/22DATE:
501 WANDO PARK BOULEVARD, SUITE 200 | MOUNT PLEASANT, SC 29464 | 508 RHETT STREET, SUITE 101 | GREENVILLE, SC 29601
500 W MAIN STCITY OF SPARTANBURG, SOUTH CAROLINACOKE FACILITYREDEVELOPMENT PHASE 1REVISION HISTORYDRAWN BY:CHECKED BY:SW+ PROJECT:
MOUNT PLEASANT, SC843.884.1667GREENVILLE, SC864.298.0534
WWW.SEAMONWHITESIDE.COMSUMMERVILLE, SC843.972.0710SPARTANBURG, SC864.272.1272CHARLOTTE, NC980.312.54506/1/23
153060SCALE: 1" = 30'0FOR NOTES AND LEGEND,SEE SHEET C1.1
FOR NOTES AND LEGEND SEE SHEET C1.1
DEMOLITION NOTES:1. CONTRACTOR IS RESPONSIBLE FOR REPAIR AND/OR REPLACEMENT OF DAMAGED ITEMS NOT TO BE DEMOLISHEDDURING CONSTRUCTION ACTIVITIES.2. CONTRACTOR IS TO DEMOLISH AND REMOVE EXISTING ASPHALT, CONCRETE AND VEGETATION WITHIN THE LIMITSOF DISTURBANCE UNLESS OTHERWISE SHOWN.3. DO NOT DISTURB EXISTING UTILITIES TO REMAIN IN SERVICE. CONTRACTOR IS TO COORDINATE UTILITYINFRASTRUCTURE DEMOLITION ACTIVITIES WITH UTILITY PROVIDER PRIOR TO COMPLETING THE WORK.4. UTILITIES NOT MARKED FOR REMOVAL ARE TO REMAIN. TERMINATE UTILITY LINE REMOVAL/DEMOLITION ACTIVITIESAT THE PROPERTY LINE UNLESS OTHERWISE NOTED.5. PRIOR TO PAVING, SAWCUT EXISTING ASPHALT OR CONCRETE SURFACES WHERE NEW ASPHALT OR CONCRETETIES TO EXISTING AND PROVIDE A SMOOTH TRANSITION.6. ALL DEMOLITION DEBRIS IS TO BE REMOVED FROM THE PROJECT SITE AND DISPOSED OF IN ACCORDANCE WITHAPPLICABLE CITY, COUNTY, STATE, AND FEDERAL REGULATIONS.7. CONTRACTOR TO ENSURE THAT ANY FILL DIRT OR WASTE DIRT IS TO BE FROM OR TO A PERMITTED SITE.UTILITY LOCATION NOTE:CONTRACTOR IS RESPONSIBLE FOR LOCATING EXISTING UTILITIES BEFORE ANYWORK IS STARTED. CONTRACTOR IS RESPONSIBLE FOR DAMAGE TO EXISTINGUTILITIES DURING CONSTRUCTION.
SURVEY NOTE:SURVEY USED WAS PERFORMED BY EAS PROFESSIONALS, INC.,DATED DECEMBER 16, 2022.
DEMOLITION NOTES:1. CONTRACTOR IS TO REMOVE TREES ONLY LOCATED WITHIN THE LIMITS OFDISTURBANCE.2. DEMOLITION DEBRIS IS TO BE REMOVED FROM THE PROJECT SITE AND DISPOSEDOF IN ACCORDANCE WITH APPLICABLE COUNTY, STATE, AND FEDERAL REGULATIONS.
CONTRACTOR NOTE:CONTRACTOR TO ENSURE ALL WORK IS CONTAINED TO WITHIN THE LIMITS OFDISTURBANCE. CONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE CAUSED TO ONSITEEXISTING FEATURES THAT ARE NOT INCLUDED WITHIN THE SCOPE OF THIS PROJECTSCDOT NOTE:ANY WORK BUILT WITHIN THE SCDOT R/W THAT IS NOT BUILT PER THE SCDOTAPPROVED PERMIT AND PLANS IS SUBJECT TO REMOVAL AND REPLACEMENT PERAPPROVED PERMIT AND PLANS AFTER INSPECTION.
TREE REMOVALDEMOLITION LEGEND:UTILITY & MISCELLANEOUSREMOVALPAVEMENT, CURB, ANDSIDEWALK REMOVAL
WATER SERVICE NOTE:1.EXISTING WATER SERVICES AND METERS TO BE REMOVED MUST FOLLOWSPARTANBURG WATER REQUIREMENTS. ALL EXISTING WATER SERVICECONNECTIONS TO THE EXISTING 6" WATER MAIN MUST BE CUT-OUT ANDSTRAIGHT-PIPED PER SPARTANBURG WATER.2.COORDINATE REMOVAL OF EXISTING WATER METERS WITH SPARTANBURGWATER SYSTEM.
R
Know what'sbelow.before you dig.Call
EXISTING UTILITY NOTE:THE LOCATION OF EXISTING UNDERGROUND UTILITIES ARESHOWN IN AN APPROXIMATE WAY ONLY AND HAVE NOT BEENINDEPENDENTLY VERIFIED BY THE OWNER OR ITSREPRESENTATIVE. THE CONTRACTOR SHALL DETERMINE THEEXACT LOCATION OF ALL EXISTING UTILITIES BEFORECOMMENCING ANY WORK, AND AGREES TO BE FULLYRESPONSIBLE FOR ANY AND ALL DAMAGES WHICH MIGHTOCCUR DUE TO THE CONTRACTOR'S FAILURE TO EXACTLYLOCATE AND PRESERVE ANY AND ALL UNDERGROUND UTILITIES.
720720725730735740745750755
705710715720
735740
735
740
735740745750
730735740745750755760765
725730735740745 730735740745750755
745750755760
755
760
730735740745750
720725730
735
720725730
735
735740
740
745
745
750
750
725725 730 735
720
725
725
725730735
740
745725730735740745750
720
725
730
715
735725730
715720725730735
725730735
725
730
735730725
720
723723 733DD
D
DD
D
DD
D
N 31° 00' 50" E 224.59OLD LOT LINE - TO BE ABANDONED
MW
D
PTCW
DOUBLE ROWREINFORCED SILT FENCE
LIMITS OF DISTURBANCE±6.50 ACRES
LIMITS OF DISTURBANCE ANDDOUBLE ROW REINFORCED SILT FENCE.PLACE SECOND ROW OF SILT FENCE ONLOD LINE.
LIMITS OF DISTURBANCE±6.50 ACRES
DOUBLE ROW REINFORCED SILT FENCE
REINFORCED SILT FENCECLEARING & GRUBBINGWITHINLIMITS OF DISTURBANCE
TYPE F INLET PROTECTION (TYP)TYPE F INLET PROTECTION TO BE USED ONEXISTING INLETS UNTIL REMOVAL OFEXISTING PAVEMENT.UPON REMOVAL OF EXISTING PAVEMENT,CONVERT TO TYPE B INLET PROTECTION.
EXISTING INLET SHOULD BE PROTECTED FROMRUNOFF BY REINFORCED SILT FENCE. IF SILT FENCECANNOT BE INSTALLED BETWEEN CATCH BASIN ANDSLOPE, TYPE B INLET PROTECTION SHOULD BE USED.
TEMPORARY CONSTRUCTION ENTRANCEPORTABLE TOILET(PORTABLE TOILETS WILL NOT BE LOCATED WITHIN 50 FEETOF WATERS OF THE STATE. AVOID PLACING PORTABLETOILETS IN CLOSE PROXIMITY TO CATCH BASINS.)CONCRETE WASHOUT BASIN
TEMPORARY STOCKPILE AREA(CONTRACTOR TO FIELDLOCATE AS NEEDED)
CONSTRUCTION DEBRIS CONTAINER(CONTRACTOR TO FIELD LOCATE ASNEEDED)EXISTINGWAREHOUSEBUILDING
EXISTINGWAREHOUSEBUILDINGEXISTING COKE BUILDING
SILT FENCE ROCK OUTLET
INSTALL REINFORCED SILT FENCEBEFORE CLEARING & GRUBBING
MAINTAIN INLET PROTECTION ON EXISTING(BYPASS) INLETS AND ENSURE THAT NOSEDIMENT ENTERS STREAM (TYP)
MAINTAIN INLET PROTECTION ON EXISTING(BYPASS) INLET AND ENSURE THAT NOSEDIMENT ENTERS STREAM (TYP)
MAINTAIN INLET PROTECTION ON EXISTING(BYPASS) INLET AND ENSURE THAT NOSEDIMENT ENTERS STORM SYSTEM (TYP)
50'CONSTRUCTIONBUFFER (TYP.)
50'CONSTRUCTIONBUFFER (TYP.)50'CONSTRUCTIONBUFFER (TYP.)
50'CONSTRUCTIONBUFFER (TYP.)50'CONSTRUCTIONBUFFER (TYP.)
BILLBOARD TO REMAIN, CONTRACTOR TOCOORDINATE WITH LAMAR ADVERTISING COMPANYFOR FILL SLOPE AROUND BASE OF STRUCTURE
C3.0EROSIONCONTROLPHASE 1 PLAN 02/16/23B D03/27/23 F04/12/23 05/17/23IJ06/02/23
COPYRIGHT c SEAMON, WHITESIDE & ASSOCIATES, INC.THIS DRAWING SHALL NOT BE REPRODUCED IN ANY MANNER OR USED FOR ANY PURPOSE WITHOUT WRITTEN PERMISSION.
GR4714DBLM/CS10/14/22DATE:
501 WANDO PARK BOULEVARD, SUITE 200 | MOUNT PLEASANT, SC 29464 | 508 RHETT STREET, SUITE 101 | GREENVILLE, SC 29601
500 W MAIN STCITY OF SPARTANBURG, SOUTH CAROLINACOKE FACILITYREDEVELOPMENT PHASE 1REVISION HISTORYDRAWN BY:CHECKED BY:SW+ PROJECT:
MOUNT PLEASANT, SC843.884.1667GREENVILLE, SC864.298.0534
WWW.SEAMONWHITESIDE.COMSUMMERVILLE, SC843.972.0710SPARTANBURG, SC864.272.1272CHARLOTTE, NC980.312.54506/1/23
204080SCALE: 1" = 40'0
SEWN R
Know what'sbelow.before you dig.Call
SURFACE TRACKING NOTE:CONTRACTOR TO TRACK ALL SLOPES AFTER INSTALLATION. SEE SURFACE TRACKING DETAILGRADING NOTE:THE GRADING OF THE PROJECT SITE SHOULD ONLY COMMENCE ONCE PERIMETER BMPs (I.E.SILT FENCE) HAVE BEEN INSTALLED. THE CONTRACTOR IS RESPONSIBLE FOR ROUTINGSTORMWATER RUNOFF TO THE PERIMETER BMPs DURING CONSTRUCTION.EROSION CONTROL BLANKET NOTE:CONTRACTOR TO INSTALL EROSION CONTROL BLANKET ON ALL SLOPES 3:1 OR STEEPER, ORGREATER THAN 8 FEET VERTICAL IN HEIGHT, AND AS SHOWN ON PLAN.
HAUL IN OR HAUL OFF SOIL NOTE:CONTRACTOR TO ENSURE THAT ANY SOIL THAT IS POTENTIALLY HAULED IN FROM OFFSITE ORHAULED OFF OF THE SITE MUST BE FROM OR GO TO A PERMITTED SITE/LOCATION. ANYAPPLICABLE PERMITTING WILL BE THE CONTRACTOR'S RESPONSIBILITY.EXISTING UTILITY NOTE:THE LOCATION OF EXISTING UNDERGROUND UTILITIES ARE SHOWN IN ANAPPROXIMATE WAY ONLY AND HAVE NOT BEEN INDEPENDENTLYVERIFIED BY THE OWNER OR ITS REPRESENTATIVE. THE CONTRACTORSHALL DETERMINE THE EXACT LOCATION OF ALL EXISTING UTILITIESBEFORE COMMENCING ANY WORK, AND AGREES TO BE FULLYRESPONSIBLE FOR ANY AND ALL DAMAGES WHICH MIGHT OCCUR DUE TOTHE CONTRACTOR'S FAILURE TO EXACTLY LOCATE AND PRESERVE ANYAND ALL UNDERGROUND UTILITIES.
SLOPE EROSION NOTE:CONTRACTOR TO ENSURE TEMPORARY DIVERSION DITCHES DO NOTCAUSE SLOPE EROSION DURING CONSTRUCTION.EROSION CONTROL PHASE 1 SEQUENCE OF CONSTRUCTION: 1.OBTAIN ALL NECESSARY PERMITS AND APPROVALS FROM THE CITY OF SPARTANBURG AND SCDHEC. AFTERRECEIVING PLAN AND PERMIT APPROVAL, SCHEDULE AN ONSITE PRE-CONSTRUCTION MEETING WITH THE ENGINEER,OWNER, CONTRACTOR, AND THE INSPECTOR BEFORE ANY MOBILIZATION OR WORK IS PERFORMED.2.INSTALL TEMPORARY CONSTRUCTION ENTRANCE, CONCRETE WASHOUT BASIN, CONSTRUCTION DEBRIS CONTAINER,AND PORTABLE TOILET. CONTRACTOR TO COORDINATE LOCATIONS OF THESE ITEMS AS NECESSARY.3.PORTABLE TOILETS WILL NOT BE LOCATED WITHIN 50 FEET OF WATERS OF THE STATE. AVOID PLACING PORTABLETOILETS IN CLOSE PROXIMITY TO CATCH BASINS.4.INSTALL PERIMETER REINFORCED SILT FENCE, AS SHOWN. CLEAR AND GRUB VEGETATION AS NEEDED TO INSTALLREINFORCED SILT FENCE. DO NOT REMOVE VEGETATION OR TREES OUTSIDE OF THE LIMITS OF DISTURBANCE.5.INSTALL INLET PROTECTION ON EXISTING CATCH BASINS. INSTALL TYPE F INLET PROTECTION ON INLETS WITHINPAVEMENT AND INSTALL TYPE B INLET PROTECTION ON INLETS IN UNPAVED AREAS.6.INSTALL THE TOPSOIL STOCKPILE AREA AND ASSOCIATED SILT FENCE, AS NECESSARY. CONTRACTOR TOCOORDINATE THE EXACT LOCATION OF THE TOPSOIL STOCKPILE AREA AS SITE CONDITIONS ALLOW.7.BEGIN CLEARING & GRUBBING ACTIVITIES WITHIN LIMITS OF DISTURBANCE.8.BEGIN DEMOLITION ACTIVITIES PER THE DEMOLITION PLAN. CONTRACTOR TO REMOVE ALL DEMOLITION ITEMS FROMTHE SITE PER ALL LOCAL, STATE, AND FEDERAL REGULATIONS.9.CONTINUE TO EROSION CONTROL PHASE 2.Concrete Washout Basin(See Detail)Rock Ditch Check(See Detail)Temporary Construction Entrance(See Detail)Reinforced Silt FencePorous BafflesLimits of DisturbanceInlet Protection(See Detail)
720720725730735740745750755
705710715720
735740
735
740
735740745750
730735740745750755760765
725730735740745 730735740745750755
745750755760
755
760
730735740745750
720725730
735
720725730
735
735740
740
745
745
750
750
725725 730 735
720
725
725
725730735
740
745725730735740745750
720
725
730
715
735725730
715720725730735
725730735
725
730
735730725
720
723723 733DD
D
DD
D
DD
D
MW
D
YI
724
735739725730
720721
722722
723723
721721721
724
736737735730725724
725723
724 734733732
724724
721722723724
726727728729
724
723
721722723
722723724
721721723724723724
722722
722
722 724
725725
725725725
725
724723724
724
723725
PTCW
LIMITS OF DISTURBANCE±6.50 ACRES
LIMITS OF DISTURBANCE±6.50 ACRES
TYPE B INLET PROTECTION (TYP)TYPE B INLET PROTECTION TO BE USEDBETWEEN REMOVAL OF EXISTING PAVEMENTAND INSTALLATION OF NEW PAVEMENT
PORTABLE TOILET(PORTABLE TOILETS WILL NOT BE LOCATED WITHIN 50 FEETOF WATERS OF THE STATE. AVOID PLACING PORTABLETOILETS IN CLOSE PROXIMITY TO CATCH BASINS.)CONCRETE WASHOUT BASINTEMPORARY CONSTRUCTION ENTRANCECLEARING & GRUBBINGWITHINLIMITS OF DISTURBANCE
DOUBLE ROWREINFORCED SILT FENCE
LIMITS OF DISTURBANCE ANDDOUBLE ROW REINFORCED SILT FENCE.PLACE SECOND ROW OF SILT FENCE ONLOD LINE. DOUBLE ROW REINFORCED SILT FENCE
REINFORCED SILT FENCE
TEMPORARY STOCKPILE AREA(CONTRACTOR TO FIELDLOCATE AS NEEDED)
EROSION CONTROL MATTINGON ALL 3:1 SLOPES
CONSTRUCTION DEBRIS CONTAINER(CONTRACTOR TO FIELD LOCATE ASNEEDED)EXISTINGWAREHOUSEBUILDING
EXISTINGWAREHOUSEBUILDINGEXISTING COKE BUILDING
SILT FENCE ROCK OUTLET
REMOVE REINFORCED SILT FENCETO GRADE CUT SLOPE. AFTERGRADING AND STABILIZING SLOPE,REINSTALL REINFORCED SILTFENCE AT BOTTOM OF SLOPE.
MAINTAIN INLET PROTECTION ON EXISTING(BYPASS) INLET AND ENSURE THAT NOSEDIMENT ENTERS STREAM (TYP)
MAINTAIN INLET PROTECTION ON EXISTING(BYPASS) INLETS AND ENSURE THAT NOSEDIMENT ENTERS STREAM (TYP)
MAINTAIN INLET PROTECTION ON EXISTING(BYPASS) INLET AND ENSURE THAT NOSEDIMENT ENTERS STORM SYSTEM (TYP)
50'CONSTRUCTIONBUFFER (TYP.)
50'CONSTRUCTIONBUFFER (TYP.)50'CONSTRUCTIONBUFFER (TYP.)
50'CONSTRUCTIONBUFFER (TYP.)50'CONSTRUCTIONBUFFER (TYP.)
BILLBOARD TO REMAIN, CONTRACTOR TOCOORDINATE WITH LAMAR ADVERTISING COMPANYFOR FILL SLOPE AROUND BASE OF STRUCTURE
C3.1EROSIONCONTROLPHASE 2 PLAN 02/16/23B D03/27/23 F04/12/23 05/17/23IJ06/02/23
COPYRIGHT c SEAMON, WHITESIDE & ASSOCIATES, INC.THIS DRAWING SHALL NOT BE REPRODUCED IN ANY MANNER OR USED FOR ANY PURPOSE WITHOUT WRITTEN PERMISSION.
GR4714DBLM/CS10/14/22DATE:
501 WANDO PARK BOULEVARD, SUITE 200 | MOUNT PLEASANT, SC 29464 | 508 RHETT STREET, SUITE 101 | GREENVILLE, SC 29601
500 W MAIN STCITY OF SPARTANBURG, SOUTH CAROLINACOKE FACILITYREDEVELOPMENT PHASE 1REVISION HISTORYDRAWN BY:CHECKED BY:SW+ PROJECT:
MOUNT PLEASANT, SC843.884.1667GREENVILLE, SC864.298.0534
WWW.SEAMONWHITESIDE.COMSUMMERVILLE, SC843.972.0710SPARTANBURG, SC864.272.1272CHARLOTTE, NC980.312.54506/1/23
204080SCALE: 1" = 40'0
SEWN R
Know what'sbelow.before you dig.Call
EROSION CONTROL PHASE 2 SEQUENCE OF CONSTRUCTION: 1.MAINTAIN ALL BMPS FROM EROSION CONTROL PHASE 1. REPAIR OR REPLACE BMPS AS NECESSARY TO ENSUREPROPER FUNCTIONALITY.2.CONTINUE DEMOLITION AND CLEARING & GRUBBING ACTIVITIES WITHIN THE LIMITS OF DISTURBANCE.3.UPON REMOVAL OF EXISTING PAVEMENT, CONVERT TYPE F INLET PROTECTION TO TYPE B INLET PROTECTION.3.BEGIN GRADING OPERATIONS. AS GRADING CONTINUES, CONTRACTOR IS RESPONSIBLE FOR MAINTAINING BMPs ON ADAILY BASIS TO ENSURE SILT DOES NOT LEAVE THE PROJECT SITE.4.INSTALL SITE STORM DRAINAGE PER THE GRADING AND DRAINAGE PLANS. INSTALL TYPE B INLET PROTECTION ATEACH INLET IMMEDIATELY UPON INSTALLATION.5.INSTALL REMAINING SITE UTILITIES, PER THE UTILITY PLAN.6.CONTINUE GRADING SITE AS NEEDED TO ACHIEVE FINAL GRADES FOR PARKING LOTS AND DRIVEWAYS, WHILEMAINTAINING BMPS. INSTALL TEMPORARY SEEDING ON ALL DENUDED AREAS.7.CONTINUE TO EROSION CONTROL PHASE 3.SURFACE TRACKING NOTE:CONTRACTOR TO TRACK ALL SLOPES AFTER INSTALLATION. SEE SURFACE TRACKING DETAILGRADING NOTE:THE GRADING OF THE PROJECT SITE SHOULD ONLY COMMENCE ONCE PERIMETER BMPs (I.E.SILT FENCE) HAVE BEEN INSTALLED. THE CONTRACTOR IS RESPONSIBLE FOR ROUTINGSTORMWATER RUNOFF TO THE PERIMETER BMPs DURING CONSTRUCTION.EROSION CONTROL BLANKET NOTE:CONTRACTOR TO INSTALL EROSION CONTROL BLANKET ON ALL SLOPES 3:1 OR STEEPER, ORGREATER THAN 8 FEET VERTICAL IN HEIGHT, AND AS SHOWN ON PLAN.
HAUL IN OR HAUL OFF SOIL NOTE:CONTRACTOR TO ENSURE THAT ANY SOIL THAT IS POTENTIALLY HAULED IN FROM OFFSITE ORHAULED OFF OF THE SITE MUST BE FROM OR GO TO A PERMITTED SITE/LOCATION. ANYAPPLICABLE PERMITTING WILL BE THE CONTRACTOR'S RESPONSIBILITY.EXISTING UTILITY NOTE:THE LOCATION OF EXISTING UNDERGROUND UTILITIES ARE SHOWN IN ANAPPROXIMATE WAY ONLY AND HAVE NOT BEEN INDEPENDENTLYVERIFIED BY THE OWNER OR ITS REPRESENTATIVE. THE CONTRACTORSHALL DETERMINE THE EXACT LOCATION OF ALL EXISTING UTILITIESBEFORE COMMENCING ANY WORK, AND AGREES TO BE FULLYRESPONSIBLE FOR ANY AND ALL DAMAGES WHICH MIGHT OCCUR DUE TOTHE CONTRACTOR'S FAILURE TO EXACTLY LOCATE AND PRESERVE ANYAND ALL UNDERGROUND UTILITIES.
SLOPE EROSION NOTE:CONTRACTOR TO ENSURE TEMPORARY DIVERSION DITCHES DO NOTCAUSE SLOPE EROSION DURING CONSTRUCTION.
SWPPP LEGEND NOTE:SEE SHEET C3.0 FOR SWPPP LEGEND
720720725730735740745750755
705710715720
735740
735
740
735740745750
730735740745750755760765
725730735740745 730735740745750755
745750755760
755
760
730735740745750
720725730
735
720725730
735
735740
740
745
745
750
750
725725 730 735
720
725
725
725730735
740
745725730735740745750
720
725
730
715
735725730
715720725730735
725730735
725
730
735730725
720
723723 733DD
D
DD
D
DD
D
MW
D
YI
724
735739725730
720721
722722
723723
721721721
724
736737735730725724
725723
724 734733732
724724
721722723724
726727728729
724
723
721722723
722723724
721721723724723724
722722
722
722 724
725725
725725725
725
724723724
724
723725
PTCW
LIMITS OF DISTURBANCE±6.50 ACRES
LIMITS OF DISTURBANCE±6.50 ACRES
TYPE F INLET PROTECTION (TYP)TYPE F INLET PROTECTION TO BE USEDUPON INSTALLATION OF NEW PAVEMENT
PORTABLE TOILET(PORTABLE TOILETS WILL NOT BE LOCATED WITHIN 50 FEETOF WATERS OF THE STATE. AVOID PLACING PORTABLETOILETS IN CLOSE PROXIMITY TO CATCH BASINS.)CONCRETE WASHOUT BASINPERMANENTSTABILIZATIONCONSTRUCTION DEBRIS CONTAINER(CONTRACTOR TO FIELD LOCATE ASNEEDED)EXISTINGWAREHOUSEBUILDING
EXISTINGWAREHOUSEBUILDINGEXISTING COKE BUILDING
MAINTAIN INLET PROTECTION ON EXISTING(BYPASS) INLETS AND ENSURE THAT NOSEDIMENT ENTERS STREAM (TYP)
MAINTAIN INLET PROTECTION ON EXISTING(BYPASS) INLET AND ENSURE THAT NOSEDIMENT ENTERS STREAM (TYP)
MAINTAIN INLET PROTECTION ON EXISTING(BYPASS) INLET AND ENSURE THAT NOSEDIMENT ENTERS STORM SYSTEM (TYP)
50'CONSTRUCTIONBUFFER (TYP.)
50'CONSTRUCTIONBUFFER (TYP.)50'CONSTRUCTIONBUFFER (TYP.)
50'CONSTRUCTIONBUFFER (TYP.)50'CONSTRUCTIONBUFFER (TYP.)
BILLBOARD TO REMAIN, CONTRACTOR TOCOORDINATE WITH LAMAR ADVERTISING COMPANYFOR FILL SLOPE AROUND BASE OF STRUCTURE
C3.2EROSIONCONTROLPHASE 3 PLAN 02/16/23B D03/27/23 F04/12/23 05/17/23IJ06/02/23
COPYRIGHT c SEAMON, WHITESIDE & ASSOCIATES, INC.THIS DRAWING SHALL NOT BE REPRODUCED IN ANY MANNER OR USED FOR ANY PURPOSE WITHOUT WRITTEN PERMISSION.
GR4714DBLM/CS10/14/22DATE:
501 WANDO PARK BOULEVARD, SUITE 200 | MOUNT PLEASANT, SC 29464 | 508 RHETT STREET, SUITE 101 | GREENVILLE, SC 29601
500 W MAIN STCITY OF SPARTANBURG, SOUTH CAROLINACOKE FACILITYREDEVELOPMENT PHASE 1REVISION HISTORYDRAWN BY:CHECKED BY:SW+ PROJECT:
MOUNT PLEASANT, SC843.884.1667GREENVILLE, SC864.298.0534
WWW.SEAMONWHITESIDE.COMSUMMERVILLE, SC843.972.0710SPARTANBURG, SC864.272.1272CHARLOTTE, NC980.312.54506/1/23
204080SCALE: 1" = 40'0
SEWN R
Know what'sbelow.before you dig.Call
SURFACE TRACKING NOTE:CONTRACTOR TO TRACK ALL SLOPES AFTER INSTALLATION. SEE SURFACE TRACKING DETAILGRADING NOTE:THE GRADING OF THE PROJECT SITE SHOULD ONLY COMMENCE ONCE PERIMETER BMPs (I.E.SILT FENCE) HAVE BEEN INSTALLED. THE CONTRACTOR IS RESPONSIBLE FOR ROUTINGSTORMWATER RUNOFF TO THE PERIMETER BMPs DURING CONSTRUCTION.EROSION CONTROL BLANKET NOTE:CONTRACTOR TO INSTALL EROSION CONTROL BLANKET ON ALL SLOPES 3:1 OR STEEPER, ORGREATER THAN 8 FEET VERTICAL IN HEIGHT, AND AS SHOWN ON PLAN.
HAUL IN OR HAUL OFF SOIL NOTE:CONTRACTOR TO ENSURE THAT ANY SOIL THAT IS POTENTIALLY HAULED IN FROM OFFSITE ORHAULED OFF OF THE SITE MUST BE FROM OR GO TO A PERMITTED SITE/LOCATION. ANYAPPLICABLE PERMITTING WILL BE THE CONTRACTOR'S RESPONSIBILITY.EXISTING UTILITY NOTE:THE LOCATION OF EXISTING UNDERGROUND UTILITIES ARE SHOWN IN ANAPPROXIMATE WAY ONLY AND HAVE NOT BEEN INDEPENDENTLYVERIFIED BY THE OWNER OR ITS REPRESENTATIVE. THE CONTRACTORSHALL DETERMINE THE EXACT LOCATION OF ALL EXISTING UTILITIESBEFORE COMMENCING ANY WORK, AND AGREES TO BE FULLYRESPONSIBLE FOR ANY AND ALL DAMAGES WHICH MIGHT OCCUR DUE TOTHE CONTRACTOR'S FAILURE TO EXACTLY LOCATE AND PRESERVE ANYAND ALL UNDERGROUND UTILITIES.
SLOPE EROSION NOTE:CONTRACTOR TO ENSURE TEMPORARY DIVERSION DITCHES DO NOTCAUSE SLOPE EROSION DURING CONSTRUCTION.
SWPPP LEGEND NOTE:SEE SHEET C3.0 FOR SWPPP LEGEND
EROSION CONTROL PHASE 3 SEQUENCE OF CONSTRUCTION: 1.MAINTAIN ALL BMPS FROM EROSION CONTROL PHASE 2. REPAIR OR REPLACE BMPS AS NECESSARY TO ENSUREPROPER FUNCTIONALITY.2.INSTALL CURB AND GUTTER WITHIN THE PARKING LOTS AND DRIVEWAYS PER THE SITE PLAN. BEGIN PAVINGOPERATIONS.3.UPON INSTALLATION OF PAVEMENT, CONVERT TYPE B INLET PROTECTION TO TYPE F INLET PROTECTION.4.CONTRACTOR TO TOP DRESS FINAL 4" TO FINISH GRADE WITH CLEAN SCREENED TOPSOIL IN ALL VEGETATED AREASPRIOR TO PERMANENT SEEDING. INSTALL PERMANENT SEEDING AND LANDSCAPING PER THE LANDSCAPE PLAN.5.REMOVE (FLUSH) ALL SEDIMENT FROM STORM DRAIN PIPES AND STRUCTURES, AS NECESSARY.6.CONTACT ENGINEER TO BEGIN CLOSE OUT PROCEDURES FOR THE PROJECT NO LATER THAN 30 DAYS BEFOREPROJECT COMPLETION. SET UP INITIAL CLOSE OUT INSPECTION WITH THE ENGINEER AND THE CITY OFSPARTANBURG INSPECTOR.7.COMPLETE CORRECTION LIST FROM INITIAL CLOSE OUT INSPECTION. SCHEDULE FINAL CLOSE OUT INSPECTION WITHENGINEER AND THE CITY OF SPARTANBURG INSPECTOR.8.REMOVE ALL TEMPORARY EROSION AND SEDIMENT CONTROL DEVICES ONCE SITE IS COMPLETELY STABILIZED.9.PERFORM GENERAL CLEANUP OF THE SITE.10.SUBMIT NOTICE OF TERMINATION TO THE CITY OF SPARTANBURG. CERTIFICATION LETTER MUST BE SUBMITTED ANDAPPROVED PRIOR TO ISSUANCE OF A CERTIFICATE OF OCCUPANCY.
C4.0EROSIONCONTROLDETAILS (1 OF2)
02/16/23B D03/27/23 F04/12/23 05/17/23IJ06/02/23
COPYRIGHT c SEAMON, WHITESIDE & ASSOCIATES, INC.THIS DRAWING SHALL NOT BE REPRODUCED IN ANY MANNER OR USED FOR ANY PURPOSE WITHOUT WRITTEN PERMISSION.
GR4714DBLM/CS10/14/22DATE:
501 WANDO PARK BOULEVARD, SUITE 200 | MOUNT PLEASANT, SC 29464 | 508 RHETT STREET, SUITE 101 | GREENVILLE, SC 29601
500 W MAIN STCITY OF SPARTANBURG, SOUTH CAROLINACOKE FACILITYREDEVELOPMENT PHASE 1REVISION HISTORYDRAWN BY:CHECKED BY:SW+ PROJECT:
MOUNT PLEASANT, SC843.884.1667GREENVILLE, SC864.298.0534
WWW.SEAMONWHITESIDE.COMSUMMERVILLE, SC843.972.0710SPARTANBURG, SC864.272.1272CHARLOTTE, NC980.312.54506/1/23
TEMPORARY CONSTRUCTION ENTRANCE1
4
5
(NOT TO SCALE)
TEMPORARY TOPSOIL STOCKPILE(NOT TO SCALE) (NOT TO SCALE)
INLET PROTECTION-TYPE F(NOT TO SCALE)
CONSTRUCTION ENTRANCESouth Carolina Department ofHealth and Environmental ControlPLAN SYMBOL
DATESouth Carolina Department ofHealth and Environmental ControlCONSTRUCTION ENTRANCEDATECONCRETE WASHOUT BASIN2(NOT TO SCALE)South Carolina Department ofHealth and Environmental ControlSTRAW BALES OR ABOVE GROUNDCONCRETE WASHOUTDATE
CONCRETEWASHOUTCONCRETE WASHOUT SIGN DETAIL
PLANTYPE "ABOVE GRADE"WITH STRAW BALESSECTION B-B
STRAW BALE BARRIER CONCRETE WASHOUT
TEMPORARY STOCKPILESouth Carolina Department ofHealth and Environmental ControlDATE
TEMPORARY STOCKPILE AREA
South Carolina Department ofHealth and Environmental ControlType FDATE
FLAT-BOTTOM TRENCH DETAIL
V-SHAPED TRENCH DETAIL
SILT FENCE INSTALLATION
STANDARD DRAWING NO.SILT FENCESouth Carolina Department ofHealth and Environmental Control
PLAN SYMBOL
DATESouth Carolina Department ofHealth and Environmental ControlSILT FENCEDATE 3REINFORCED SILT FENCE
6INLET PROTECTION-TYPE B(NOT TO SCALE)7TRACKING(NOT TO SCALE)South Carolina Department ofHealth and Environmental Control
C4.1EROSIONCONTROLDETAILS (2 OF2)
02/16/23B D03/27/23 F04/12/23 05/17/23IJ06/02/23
COPYRIGHT c SEAMON, WHITESIDE & ASSOCIATES, INC.THIS DRAWING SHALL NOT BE REPRODUCED IN ANY MANNER OR USED FOR ANY PURPOSE WITHOUT WRITTEN PERMISSION.
GR4714DBLM/CS10/14/22DATE:
501 WANDO PARK BOULEVARD, SUITE 200 | MOUNT PLEASANT, SC 29464 | 508 RHETT STREET, SUITE 101 | GREENVILLE, SC 29601
500 W MAIN STCITY OF SPARTANBURG, SOUTH CAROLINACOKE FACILITYREDEVELOPMENT PHASE 1REVISION HISTORYDRAWN BY:CHECKED BY:SW+ PROJECT:
MOUNT PLEASANT, SC843.884.1667GREENVILLE, SC864.298.0534
WWW.SEAMONWHITESIDE.COMSUMMERVILLE, SC843.972.0710SPARTANBURG, SC864.272.1272CHARLOTTE, NC980.312.54506/1/23
1EROSION CONTROL MATTING(NOT TO SCALE)
2"-5"(5-12.5cm)3B 42
5 13A
12"(30cm)6"(15cm)6"(15cm)
*NOTE:In loose soilconditions, the useof staple or stakelengths greater than6"(15cm) may benecessary toproperly secure theRECP's.3"(7.5cm)
N 66° 01' 57" E86.48'S 23° 43' 22" E53.04'S 66° 02' 28" W84.95'N 25° 23' 31" W38.36'
S 21° 07' 12" E(TIE) 21.53'
S 57° 15' 36" E46.10'
S 65° 44' 37" W 357.56'
N 39° 43' 46" W 163.66'
N 24° 02' 40" W 360.16'
N 06° 37' 36" W67.42'
N 36° 10' 34" W 161.91'S 32° 41' 58" W62.58'N 69° 44' 16" W103.08'
N 25° 46' 14" W 94.96'
N 25° 39' 52" W 99.96'
N 25° 32' 43" W49.91'
N 25° 32' 12" W49.88'N 26° 02' 01" W29.94'S 67° 46' 25" W82.66'N 03° 34' 47" E85.11'
N 03° 49' 21" E45.18'
N 08° 16' 19" E84.75'L1L2
S 57° 45' 15" E 205.48'
L3L4S 56° 49' 57" E 143.66'
S 57° 48' 23" E 125.24'
S 80° 26' 14" E 274.87'
L5
S 25° 46' 10" E 569.69'
S 17° 35' 34" E132.25'
CEDAR STREET15' R/W WIDTH PER PB 2PG 72UNIMPROVEDAREA:4,545 SFOR 0.10 OFAN ACREN/F: ROSIE MILLERTMS: 7-12-13-050.00DB 123-M PG 788PB 2 PG 71-72N/F: MARSHALL CLARK ET ALTMS: 7-12-13-048.00DB 127-M PG 659PB 2 PG 71-72
N/F: DEBORAH HOLMESTMS: 7-12-09-156.00DB 132-C PG 276
N/F: VICTOR JOSEPHTMS: 7-12-09-190.00DB 115-N PG 644PB 51 PG 664
N/F: CITY OF SPARTANBURGTMS: 7-12-09-200.00DB 101-R PG 762
N/F: THE BANKS LAW FIRM PATMS: 7-12-13-051.00DB 129-V PG 870
N/F: PALMETTOOPERATING COMPANY, LLCTMS 7-12-13-049.00DB 130-K PG 599PB 175 PG 56
N/F: STEPHEN WASHINGTONTMS: 7-12-13-042.00DB 122-L PG 874N/F: CAROLINA INS& INVESTMENT COTMS: 7-12-13-041.00DB 33-D PG 495N/F: KAPASI INVESTMENTS, LLCTMS: 7-12-13-040.00DB 93-Q PG 778PB 165 PG 738
N/F: JAMES & LYNN FLYNNTMS: 7-12-13-035.00DB 75-U PG 533PB 177 PG 568N/F: NEW LIFE MINISTRIESCHURCH OF SPARTANBURGTMS: 7-12-13-038.00DB 70-T PG 575PB 29 PG 52N/F: SPANN VENTURES LLCTMS: 7-12-13-037.00DB 124-A 569PB 10 PG 100
N/F: CAPA REAL ESTATE LLCTMS: 7-12-13-005.00DB 132-K PG 598PB 151 PG 360N/F: EARLE CLOWNEY ETALTMS: 7-12-13-004.00DB 64-U PG 668N/F: MOLLY UZORTMS: 7-12-13-003.00DB 89-R PG 634PB 134 PG 811N/F: DAX PROPERTIES LLCTMS: 7-12-13-002.01DB 133-L PG 1PB 92 PG 75N/F: DAX PROPERTIES LLCTMS: 7-12-13-002.00DB 133-L PG 1PB 92 PG 75N/F: ETHAN FLOYDTMS: 7-11-12-313.00DB 132-C PG 708PB 135 PG 66N/F: LAW PETERTMS: 7-11-12-312.00DB 114-X PG 845PB 130 PG 202N/F: JOSEPHWILKES,DAVID MEADOR& MCKINLEYWILKESTMS: 7-11-12-311.00DB 139-H PG 329PB 130 PG 202
N/F: MARSHALL CLARK ET ALTMS: 7-12-13-047.00DB 127-M PG 659PB 2 PG 71-72
N/F: JBURKE INVESTMENTS LLCTMS: 7-12-13-020.00DB 124-Z PG 405PB 25-266
VAN
EXISTING BUILDING(PROPOSED RESTAURANT)EXISTING BUILDING(PROPOSED GYM)EXISTING FACILITY(PROPOSED MIXED-USE)
EXISTING LOADING DOCK
W MAIN STSC HWY 2975' R/W PER PB 175 PG 56
OXFORD RD50' R/W PER PB 175 PG 56
MONK STR/W UNKNOWN
WHITEFORD RD
ADA ACCESSIBLE ROUTE(TYP)
ADA ACCESSIBLE ROUTE(TYP)
PHASE TWO(SHOWN FOR REFERENCE ONLY. PHASE 2 DRAWINGS NOTINCLUDED IN THIS PERMIT SUBMITTAL. PHASE 2 DRAWINGSTO BE SUBMITTED AT A FUTURE DATE TBD)PHASE LINE
WATER FEATURE / AMENITY AREA(DESIGN BY OTHERS - SEE ARCHITECTURALDRAWINGS FOR DETAILS)
50' CONSTRUCTIONBUFFER FROMCENTERLINE (TYP)
50' CONSTRUCTIONBUFFER FROMCENTERLINE (TYP)
RI/RO DRIVEWAY
FULL-ACCESSDRIVEWAY
PRIVATE DRIVE TOCONNECT TO OXFORD RD
SUTERA SEMI-INGROUDTRASH RECEPTACLES (TYP)
TRASH COLLECTION:COKE BUILDING TRASH TO BE LOCATED WITHIN BUILDINGAND HAULED OFF FROM LOADING AREALOADING AREAELEVATOR(BY OTHERS)
C5.0OVERALL SITEPLAN 02/16/23B D03/27/23 F04/12/23 05/17/23IJ06/02/23
COPYRIGHT c SEAMON, WHITESIDE & ASSOCIATES, INC.THIS DRAWING SHALL NOT BE REPRODUCED IN ANY MANNER OR USED FOR ANY PURPOSE WITHOUT WRITTEN PERMISSION.
GR4714DBLM/CS10/14/22DATE:
501 WANDO PARK BOULEVARD, SUITE 200 | MOUNT PLEASANT, SC 29464 | 508 RHETT STREET, SUITE 101 | GREENVILLE, SC 29601
500 W MAIN STCITY OF SPARTANBURG, SOUTH CAROLINACOKE FACILITYREDEVELOPMENT PHASE 1REVISION HISTORYDRAWN BY:CHECKED BY:SW+ PROJECT:
MOUNT PLEASANT, SC843.884.1667GREENVILLE, SC864.298.0534
WWW.SEAMONWHITESIDE.COMSUMMERVILLE, SC843.972.0710SPARTANBURG, SC864.272.1272CHARLOTTE, NC980.312.54506/1/23
SCALE: 1" = 50'25501000
SEWN
GENERAL NOTES:A.ALL DISTURBED AREAS OUTSIDE OF PAVEMENT AREAS ARE TO BE STABILIZED ANDSEEDED IMMEDIATELY AFTER REACHING GRADE. AREAS TO BEVEGETATED/LANDSCAPED PER LANDSCAPING PLAN.B.ISLANDS WITHIN PARKING AREA TO BE STABILIZED AND SEEDED DURINGCONSTRUCTION. AREAS TO BE VEGETATED/LANDSCAPED PER LANDSCAPE PLANS.C.CONTRACTOR TO ENSURE THAT ADA ACCESSIBLE ROUTE MEETS ALL ACCESSIBLEGUIDELINES.D.SEE DETAILS FOR ADA RAMP TYPE.E.ALL CURBING IN FRONT OF SITE FIRE PROTECTION SERVICES (REMOTE FDC AND FIREHYDRANTS) SHALL BE BE PAINTED RED WITH NO PARKING IN WHITE TEXT ALONG THEFACE OF CURB. CONTRACTOR TO COORDINATE WITH CITY OF SPARTANBURG BUILDINGDEPARTMENT.F.W MAIN STREET STREETSCAPE TO MEET SCDOT SIGHT DISTANCE REQUIREMENTS
SITE PLAN NOTES:1.ALL EXISTING DRIVEWAYS AND CURB CUTS THAT ARE NOT USED SHALL BE REMOVEDAND REPLACED WITH CONCRETE CURBING, GUTTER, AND/OR SIDEWALK (IF EXISTING).2.ALL PLANTING AREAS SHALL BE MECHANICALLY IRRIGATED.3.THE DUMPSTER PAD AND SCREENING SHALL COMPLY WITH CITY STANDARDS AS FOUNDIN SECTION 504.6 AND 505.63 OF THE CITY OF SPARTANBURG ZONING ORDINANCE.4.ALL HANDICAP SPACES WILL BE MARKED WITH A FREESTANDING OR WALL MOUNTEDSIGN. THE HANDICAP SIGN SHALL BE 7FT IN HEIGHT FROM BOTTOM OF THE SIGN ORABOVE DRIVING SURFACE. (SEE DETAIL)5.ALL SIGNAGE SHALL COMPLY WITH THE CITY OF SPARTANBURG ZONING ORDINANCE.6.ALL LANDSCAPED AREAS WILL BE DELINEATED BY CURBING.
RETAINING WALLS / DESIGN BUILD: 1.RETAINING WALLS SHALL BE PROVIDED AND INSTALLED BY THE CONTRACTOR AS ADESIGN/BUILD COMPONENT OF THE PROJECT. SUBMITTALS SHALL BE SEALED BY A SCPROFESSIONAL ENGINEER AND SUBMITTED TO THE GEOTECHNICAL ENGINEER FORREVIEW. THE DESIGN SHALL ENCOMPASS ALL COMPONENTS AND ASPECTS OF THEWALL, SUCH AS FOUNDATIONS, TIEBACKS, DRAINAGE PROTECTION (SURFACE ANDGROUNDWATER), AND EROSION PROTECTION. THE CONTRACTOR SHALL BERESPONSIBLE FOR PROVIDING PROPER BACKFILL MATERIAL IF THE ON-SITE SOIL ISUNSUITABLE.2.THE RETAINING WALL STRUCTURE SHALL BE INSTALLED COMPLETE WITH WATERREPELLENCY AND FOUNDATION DRAINAGE TO PREVENT EFFLORESCENCE. BOTTOMASH SHALL NOT BE PERMITTED IN THE CMU MATERIAL.3.42" TALL GUARDRAIL FENCE TO BE INSTALLED ON TOP OF WALL WHERE FALL HEIGHTEXCEEDS 30" PER IBC.
SCDOT NOTES:1.ANY WORK BUILT WITHIN THE SCDOT R/W THAT IS NOT BUILT PER THE SCDOTAPPROVED PERMIT AND PLANS IS SUBJECT TO REMOVAL AND REPLACEMENT PERAPPROVED PERMIT AND PLANS AFTER INSPECTION.2.CONTRACTOR SHALL REFER TO THE APPROVED TRAFFIC SIGNAL PLANS PREPARED BYTRAFFIC ENGINEER FOR ALL REQUIRED TRAFFIC SIGNAL AND PAVEMENT MARKINGWORK WITHIN SCDOT R/W.3.THE CONTRACTOR SHALL MARK THE CENTERLINE OF EACH DRIVEWAY IN THE FIELDAND COMPLETE ANY CLEARING ALONG THE PROPERTY FRONTAGE AS NEEDED. ONCEMARKED AND THE CLEARING IS COMPLETE, THE CONTRACTOR SHALL NOTIFY SCDOTTO SCHEDULE A SITE VISIT TO VERIFY COMPLIANCE.4.ALL PAVEMENT MARKINGS WITHIN SCDOT RIGHT-OF-WAY ARE TO BE THERMOPLASTIC.ANY PAVEMENT REDONE IN THE SCDOT R.O.W. SHALL MEET SCDOT STANDARDS.5.
EXISTING UTILITY NOTE:THE LOCATION OF EXISTING UNDERGROUND UTILITIES ARE SHOWN IN AN APPROXIMATE WAYONLY AND HAVE NOT BEEN INDEPENDENTLY VERIFIED BY THE OWNER OR ITSREPRESENTATIVE. THE CONTRACTOR SHALL DETERMINE THE EXACT LOCATION OF ALLEXISTING UTILITIES BEFORE COMMENCING ANY WORK, AND AGREES TO BE FULLYRESPONSIBLE FOR ANY AND ALL DAMAGES WHICH MIGHT OCCUR DUE TO THECONTRACTOR'S FAILURE TO EXACTLY LOCATE AND PRESERVE ANY AND ALL UNDERGROUNDUTILITIES.
STANDARD DUTY ASPHALTHEAVY DUTY ASPHALTCONCRETE SIDEWALKADA PARKING CONCRETEHEAVY DUTY CONCRETEPARKING COUNTADA ACCESSIBLE PATH(CIRCLE ON PATH INDICATES AN AREA IS ACCESSIBLEW/ MULTIPLE POTENTIAL ROUTES)
SITE LEGEND
09
INTERMITTENTSTREAM 1 (CONT.)
PERENNIALSTREAM 1(CONT.)
INTERMITTENTSTREAM 1105 LF
VAN
90°TYP
45°TYP
22' TYP
EXISTING BUILDING(PROPOSED RESTAURANT)EXISTING BUILDING(PROPOSED GYM)
R10'TYP
R10'TYP
R4'TYP
R4'TYPR4'TYP
18' ADATYP9' ADATYP
R4'TYP
R4'TYP
24'TYP24'TYP
24'
9'TYP18'TYP
9'TYP19'TYP
19' ADATYP
9' ADATYP16'TYP
16'TYP
19'TYP9'TYPR77.5'9'TYPR15'TYP
26'TYP
R86.5'R188'R212'
6'TYPR15'TYP
6'6'
R20'R20'
R10'TYP20'5'
R25'
R30'
31'26'TYP
R4'
R2'
R2'
R4'TYP6'5'
R2'
5'
18'TYP9'TYP
8' ADA ACCESSAISLE5.3'9'ADA
24'
5'
6'
R133'
(2) SUTERA SP-6 SEMI IN-GROUNDWASTE CONTAINMENT UNITS
(3) SUTERA SP-6 SEMI IN-GROUNDWASTE CONTAINMENT UNITS
STANDARD DUTY ASPHALTPAVEMENT (TYP)HEAVY DUTY ASPHALTPAVEMENT (TYP)CONCRETE SIDEWALKPAVEMENT (TYP)
ADA CURB RAMP W/ DETECTABLEWARNING - TYPE C (TYP)PHASE 2 DRIVEWAYSTUB-OUT
PHASE 2 DRIVEWAYSTUB-OUT
HEAVY DUTY CONCRETEPAVEMENT (TYP)ADA CURB RAMP W/ DETECTABLEWARNING - TYPE A (TYP)(3) U-SHAPED BIKE RACKS(PHASE 1 BIKE PARKING)
STANDARD DUTY ASPHALTPAVEMENT (TYP)
SCDOT DRIVEWAY W/ SEPARATED SIDEWALK(SEE SCDOT DRAWING 720-410-00)ADA CURB RAMP W/DETECTABLE WARNING
CONCRETE SIDEWALKPAVEMENT (TYP)
CONCRETE SIDEWALKPAVEMENT (TYP)18" CURB & GUTTER (TYP)ADA CURB RAMP W/ DETECTABLEWARNING - TYPE B
ADA CURB RAMP W/ DETECTABLEWARNING - TYPE A (TYP)
RIGHT-IN / RIGHT-OUT DRIVEWAY -SCDOT DRIVEWAY W/ SEPARATED SIDEWALK(SEE SCDOT DRAWING 720-410-00)
6' WIDE PAINTEDCROSSWALKSTOP SIGN (R1-1-30) &PAINTED STOP BAR (TYP)WITH "NO LEFT TURN" SIGN (R3-2) WITH7AM - 9AM AND 4PM - 6PM RESTRICTION
ADA CURB RAMP W/ DETECTABLEWARNING - TYPE C (TYP)CONCRETE SIDEWALKPAVEMENT (TYP)18" CURB & GUTTER(TYP)
HEAVY DUTY ASPHALTPAVEMENT (TYP)
EXISTING FACILITY(PROPOSED MIXED-USE)
SEGMENTAL BLOCK RETAINING WALL(SEE SHEET C5.0 FOR RETAINING WALL NOTES)(WALL DESIGN BY STRUCTURAL ENGINEER)
EXISTING WALL TOREMAIN
TIE TO EXISTING SIDEWALK -CONTRACTOR TO MATCH EXISTING GRADESAND ENSURE POSITIVE DRAINAGE (TYP)TIE TO EXISTING CURB & GUTTER -CONTRACTOR TO MATCH EXISTING GRADESAND ENSURE POSITIVE DRAINAGE (TYP)
EXISTING LOADING DOCK
5'5'TYP
10'
4.5'
5'15'
16'14'
HEAVY DUTY CONCRETEPAVEMENT (TYP)
LOADING ZONEELEVATOR(ADA ACCESSIBLE ROUTE)GRAND STAIRCASEWATER FEATURE(DESIGN BY OTHERS)LOWER CONCRETETERRACE
CAST-IN-PLACE CONCRETE RETAINING WALL(SEE SHEET C5.0 FOR RETAINING WALL NOTES) (TYP)(SEE ARCH. DRAWINGS FOR DETAILS OF GUARDRAIL FENCE)(WALL DESIGN BY STRUCTURAL ENGINEER)
VEHICULAR SPEED TABLE W/ LEVELPEDESTRIAN CROSSING
OUTDOOR PLAZA(FINAL DESIGN TBD)
OUTDOOR PLAZA(FINAL DESIGN TBD)
LOWER LAWNAREA
UPPER CONCRETE TERRACER4'
TIE TO EXISTING ASPHALT AND CURB & GUTTER -CONTRACTOR TO MATCH EXISTING GRADES ANDENSURE POSITIVE DRAINAGE (TYP)
CONCRETE STEPS & HANDRAILS(SEE ARCH. PLANS FOR DETAILS)(TYP)ADA CONCRETE RAMPS W/ HANDRAILS(SEE ARCH. PLANS FOR DETAILS)9.5' DROP-OFFZONEVEHICULAR RATEDBOLLARDS (TYP)
LOCATION OF DEVELOPMENT SIGN(DESIGN TBD)
50'CONSTRUCTIONBUFFER (TYP)
50'CONSTRUCTIONBUFFER (TYP)
DETECTABLE WARNINGSURFACE (TYP)50'CONSTRUCTIONBUFFER (TYP)50'CONSTRUCTIONBUFFER (TYP)UPPER LAWNAREA
TIE TO EXISTING SIDEWALK -CONTRACTOR TO MATCH EXISTING GRADESAND ENSURE POSITIVE DRAINAGE (TYP)TIE TO EXISTING CURB & GUTTER -CONTRACTOR TO MATCH EXISTING GRADESAND ENSURE POSITIVE DRAINAGE (TYP)HEAVY DUTY ASPHALTPAVEMENT (TYP)
OUTDOOR AMENITY AREA:WATER FEATURE, ELEVATOR, GRANDSTAIRCASE, TERRACES, ETC.(DESIGN BY OTHERS - SEE ARCH.DRAWINGS FOR DETAILS)
0608 0807120909050807
09
0705 06
0711
0903
STOP SIGN (R1-1-30) &PAINTED STOP BAR (TYP)
03
PHASE LINE
CONCRETE ADA PARKING SPACESW/ PRECAST WHEELSTOPS (TYP)
CONCRETE ADA PARKING SPACESW/ PRECAST WHEELSTOPS (TYP)
TRANSFORMERLOCATION
W MAIN STSC HWY 2975' R/W PER PB 175 PG 56
OXFORD RD50' R/W PER PB 175 PG 56
MONK STR/W UNKNOWN
WHITEFORD RD
STOP SIGN (R1-1-30) &PAINTED STOP BAR (TYP)
BILLBOARD TO REMAIN, COORDINATEWITH LAMAR ADVERTISING COMPANY
SCISSOR LIFT(SEE ARCH. DRAWINGS FOR DETAILS)4'CONCRETE PATIOSEGMENTAL BLOCK RETAINING WALL(SEE SHEET C5.0 FOR RETAINING WALL NOTES)(WALL DESIGN BY STRUCTURAL ENGINEER)
TRANSFORMERLOCATION
C5.1SITE PLANA10/14/22 02/16/23B D03/27/23 F04/12/23 05/17/23IJ06/02/23
COPYRIGHT c SEAMON, WHITESIDE & ASSOCIATES, INC.THIS DRAWING SHALL NOT BE REPRODUCED IN ANY MANNER OR USED FOR ANY PURPOSE WITHOUT WRITTEN PERMISSION.
GR4714DBLM/CS10/14/22DATE:
501 WANDO PARK BOULEVARD, SUITE 200 | MOUNT PLEASANT, SC 29464 | 508 RHETT STREET, SUITE 101 | GREENVILLE, SC 29601
500 W MAIN STCITY OF SPARTANBURG, SOUTH CAROLINACOKE FACILITYREDEVELOPMENT PHASE 1REVISION HISTORYDRAWN BY:CHECKED BY:SW+ PROJECT:
MOUNT PLEASANT, SC843.884.1667GREENVILLE, SC864.298.0534
WWW.SEAMONWHITESIDE.COMSUMMERVILLE, SC843.972.0710SPARTANBURG, SC864.272.1272CHARLOTTE, NC980.312.54506/1/23
153060SCALE: 1" = 30'0
SEWNSTANDARD DUTY ASPHALTHEAVY DUTY ASPHALTCONCRETE SIDEWALKADA PARKING CONCRETEHEAVY DUTY CONCRETEPARKING COUNT
SITE LEGEND
09
SCDOT RAISED CONCRETE MEDIAN(SEE ARMS MANUAL APPENDIX A FIGURE A-7.1)
SCDOT NOTE:1.ANY WORK BUILT WITHIN THE SCDOT R/W THAT IS NOT BUILT PER THE SCDOTAPPROVED PERMIT AND PLANS IS SUBJECT TO REMOVAL AND REPLACEMENTPER APPROVED PERMIT AND PLANS AFTER INSPECTION.2.ALL EXISTING ASPHALT REMOVAL FOR DRIVEWAY TIE-INS SHALL BE SAW-CUTTO CREATE A SMOOTH TRANSITION AND TIE-IN.3.CONTRACTOR SHALL REFER TO THE APPROVED TRAFFIC SIGNAL PLANSPREPARED BY TRAFFIC ENGINEER FOR ALL REQUIRED TRAFFIC SIGNAL ANDPAVEMENT MARKING WORK WITHIN SCDOT R/W.4.NO WORK TO OCCUR ALONG US 29 ON MONDAY-FRIDAY FROM 7AM - 8PM.
© 2023 Microsoft Corporation © 2023 Maxar ©CNES (2023) Distribution Airbus DS
24'26'
24.9'22'
48'36'
46'34'
5'
146' DRIVEWAY SPACING
30' THROAT LENGTH
23.2' THROAT LENGTH LOCATION OF DEVELOPMENT SIGN(DESIGN TBD)
STOP SIGN (R1-1-30) &PAINTED STOP BAR (TYP)WITH "NO LEFT TURN DURING PEAKHOURS" SIGN (R3-2) WITH 7AM - 9AMAND 4PM - 6PM RESTRICTION
HEAVY DUTY ASPHALTPAVEMENT (TYP)
TIE TO EXISTING CURB & GUTTER -CONTRACTOR TO MATCH EXISTING GRADESAND ENSURE POSITIVE DRAINAGE (TYP)
TIE TO EXISTING SIDEWALK -CONTRACTOR TO MATCH EXISTING GRADESAND ENSURE POSITIVE DRAINAGE (TYP)TIE TO EXISTING CURB & GUTTER -CONTRACTOR TO MATCH EXISTING GRADESAND ENSURE POSITIVE DRAINAGE (TYP)
TIE TO EXISTING SIDEWALK -CONTRACTOR TO MATCH EXISTING GRADESAND ENSURE POSITIVE DRAINAGE (TYP)RIGHT-IN / RIGHT-OUT DRIVEWAY -SCDOT DRIVEWAY W/ SEPARATED SIDEWALK(SEE SCDOT DRAWING 720-410-00)STOP SIGN (R1-1-30) W/ "NO LEFTTURN" SIGN (R3-2-24) &PAINTED STOP BAR (TYP)CONCRETE SIDEWALKPAVEMENT (TYP)45' DRIVEWAY SPACING138.2' DRIVEWAY SPACING
29.5' DRIVEWAY SPACINGEXISTING CURB CUT
SCDOT DRIVEWAY W/ SEPARATED SIDEWALK(SEE SCDOT DRAWING 720-410-00)
28.5' DRIVEWAY SPACING
ENSURE PEDESTRIANS HAVE SIDEWALK ACCESSTHROUGHOUT CONSTRUCTION ACTIVITIES.PROVIDE DETOURS AS NECESSARY TO ENSURENO BLOCKAGE OF PEDESTRIAN TRAFFIC.ENSURE PEDESTRIANS HAVE SIDEWALK ACCESSTHROUGHOUT CONSTRUCTION ACTIVITIES.PROVIDE DETOURS AS NECESSARY TO ENSURENO BLOCKAGE OF PEDESTRIAN TRAFFIC.
MAIN DRIVEWAY PROFILE720725730720725730
-0+20EG:FG:0+00EG:725.90FG:EG:725.98FG:725.420+98.33EG:FG:RIRO DRIVEWAY PROFILE730735740730735740
-0+20EG:FG:0+00EG:732.47FG:EG:733.41FG:732.731+00EG:FG:1+02.28EG:FG:
4.38%1.75%-3.35%-2.16%4.16%1.70%6.52%5.63% EXISTING GRADEPROPOSED GRADEEXISTING GRADEPROPOSED GRADESIDEWALK RAMP CONCRETE(SHOWN FOR EXTENTS ONLY)SIDEWALK RAMP CONCRETE(SHOWN FOR EXTENTS ONLY)
51020SCALE: 1" = 10'0
SEWN
COPYRIGHT c SEAMON, WHITESIDE & ASSOCIATES, INC.THIS DRAWING SHALL NOT BE REPRODUCED IN ANY MANNER OR USED FOR ANY PURPOSE WITHOUT WRITTEN PERMISSION.
GR4714DBLM/CS10/14/22DATE:
501 WANDO PARK BOULEVARD, SUITE 200 | MOUNT PLEASANT, SC 29464 | 508 RHETT STREET, SUITE 101 | GREENVILLE, SC 29601
500 W MAIN STCITY OF SPARTANBURG, SOUTH CAROLINACOKE FACILITYREDEVELOPMENT PHASE 1REVISION HISTORYDRAWN BY:CHECKED BY:SW+ PROJECT:
MOUNT PLEASANT, SC843.884.1667GREENVILLE, SC864.298.0534
WWW.SEAMONWHITESIDE.COMSUMMERVILLE, SC843.972.0710SPARTANBURG, SC864.272.1272CHARLOTTE, NC980.312.54506/1/23
R
Know what'sbelow.before you dig.CallFOR NOTES AND LEGEND,SEE SHEET C1.1
SCDOT DRIVEWAY SITE PLAN NOTE:THE CONTRACTOR SHALL MARK THE CENTERLINE OF EACH DRIVEWAY IN THE FIELDAND COMPLETE ANY CLEARING ALONG THE PROPERTY FRONTAGE AS NEEDED. ONCEMARKED AND THE CLEARING IS COMPLETE, THE CONTRACTOR SHALL NOTIFY SCDOTTO SCHEDULE A SITE VISIT TO VERIFY COMPLIANCE.SCDOT PAVEMENT NOTE:ALL PAVEMENT MARKINGS WITHIN SCDOT RIGHT-OF-WAY ARE TO BE THERMOPLASTIC.ANY PAVEMENT REDONE IN THE SCDOT R.O.W. SHALL MEET SCDOT STANDARDS.
SCDOT NOTE:1.ANY WORK BUILT WITHIN THE SCDOT R/W THAT IS NOT BUILT PER THE SCDOTAPPROVED PERMIT AND PLANS IS SUBJECT TO REMOVAL AND REPLACEMENTPER APPROVED PERMIT AND PLANS AFTER INSPECTION.2.ALL EXISTING ASPHALT REMOVAL FOR DRIVEWAY TIE-INS SHALL BE SAW-CUTTO CREATE A SMOOTH TRANSITION AND TIE-IN.3.CONTRACTOR SHALL REFER TO THE APPROVED TRAFFIC SIGNAL PLANSPREPARED BY TRAFFIC ENGINEER FOR ALL REQUIRED TRAFFIC SIGNAL ANDPAVEMENT MARKING WORK WITHIN SCDOT R/W.4.NO WORK TO OCCUR ALONG US 29 ON MONDAY-FRIDAY FROM 7AM - 8PM.
C5.2SCDOTDRIVEWAYPLAN 02/16/23B D03/27/23 F04/12/23 05/17/23IJ06/02/23
W MAIN ST(US HWY 29)75' R/W, PB 175 PG 56SCDOT FILE NO. 42.959, SHEET 10ASPEED LIMIT: 35 MPH
SCALE: 1" = 50'25501001.0'2.5'5.0'0.0'SCALE: 1" = 5.0'0
WSOWSOWSOHYD
VAN
PUBLIC FIRE HYDRANT ASSEMBLY
EXISTING PUBLIC FIREHYDRANT ASSEMBLY
REMOTE FIRE DEPARTMENT CONNECTION (FDC)
REMOTE FIRE DEPARTMENT CONNECTION (FDC)
283' HOSE PULL
291' HOSE PULL
PUBLIC FIRE HYDRANT ASSEMBLYREMOTE FIRE DEPARTMENTCONNECTION (FDC)
351' HOSE PULL152' HOSE PULL
178' HOSE PULL
209' HOSE PULL
150' HOSE PULL
246' HOSE PULL
PUMPER FIRE TRUCK FROM AUTODESKVEHICLE TRACKING SOFTWARETURNING RADIUS = 25.75'
FIRE TRUCK TURNING TEMPLATEFROM CITY OF SPARTANBURGTURNING RADIUS = 21.25'
WSOWSOWSOHY
VAN
COPYRIGHT c SEAMON, WHITESIDE & ASSOCIATES, INC.THIS DRAWING SHALL NOT BE REPRODUCED IN ANY MANNER OR USED FOR ANY PURPOSE WITHOUT WRITTEN PERMISSION.
GR4714DBLM/CS10/14/22DATE:
501 WANDO PARK BOULEVARD, SUITE 200 | MOUNT PLEASANT, SC 29464 | 508 RHETT STREET, SUITE 101 | GREENVILLE, SC 29601
500 W MAIN STCITY OF SPARTANBURG, SOUTH CAROLINACOKE FACILITYREDEVELOPMENT PHASE 1REVISION HISTORYDRAWN BY:CHECKED BY:SW+ PROJECT:
MOUNT PLEASANT, SC843.884.1667GREENVILLE, SC864.298.0534
WWW.SEAMONWHITESIDE.COMSUMMERVILLE, SC843.972.0710SPARTANBURG, SC864.272.1272CHARLOTTE, NC980.312.54506/1/23
C5.3LIFE SAFETYPLAN 02/16/23B D03/27/23 F04/12/23 05/17/23IJ06/02/23 153060SCALE: 1" = 30'0
SEWNGENERAL NOTE:1.ALL SCOPE OF WORK SHOWN IS INACCORDANCE WITH 2018INTERNATIONAL BUILDING CODE (IBC),2019 NFPA 24, AND 2018 INTERNATIONALFIRE CODE (IFC)
FIRE ACCESS LEGEND:HOSE PULLPROPOSED FIREHYDRANTPROPOSED FDC
OXFORD ROADSOLID WASTE VEHICLE TURN-AROUNDPARKING LOTFIRE TRUCK TURN-AROUND
720720725
705710715720
735
740730735740
720725730
735
720725730
735
735740
740
745
745
750
750
725725 730 735
720
725
725
725730735
740
745725730735740745
720
725
730
715
735725730
715720725730735
725730735
725
730
720
723723 733
D
D
D DD
D
DD
D
MONK STR/W UNKNOWN
OXFORD RD50' R/W PER PB 175 PG 56
W MAIN STSC HWY 2975' R/W PER PB 175 PG 56
INTERMITTENTSTREAM 1 (CONT.)
PERENNIALSTREAM 1(CONT.)
INTERMITTENTSTREAM 1105 LF
~ASPHALT~
~ASPHALT~D
VAN
YI
724
735739725730
720721
722722
723 723
721
721
721EXISTINGWAREHOUSEBUILDINGEX. FFE: ±724.8
EXISTINGWAREHOUSEBUILDINGEX. FFE: ±722.7EX. FFE: ±725.3
EX. FFE: ±735.4
EXISTING DOCK
EX. FFE: ±735.4EXISTING COKE BUILDING
724
736737735730725724
725
723
724
734733732
TC:723.00BC:722.50
TC:720.75BC:720.25724724
721
722723724
726727728729
724
723
721722723
722723724
721721723724723724
722722
722
722
724
725
725
725725725
725
724723724
724
723725
TC:725.50BC:725.00TC:724.00BC:723.50TC:724.50BC:724.00TC:724.05BC:723.55
724.80724.70TC:723.63BC:723.13724.00724.90TC:723.50BC:723.00TC:722.50BC:722.00
TC:723.90BC:723.40TC:723.50BC:723.00TC:723.30BC:722.80TC:723.75BC:722.25
TC:721.40BC:720.90TC:721.40BC:720.90TC:721.20BC:720.70TC:721.00BC:720.50TC:722.70BC:722.20
735.00TC:735.50BC:735.00TC:735.80BC:735.30TC:735.80BC:735.30TC:735.25BC:734.75TC:735.25BC:734.75TC:735.50BC:735.00
TC:721.10BC:720.60
TC:724.50BC:724.00TC:722.70BC:722.20TC:722.50BC:722.00TC:721.20BC:720.70
TC:722.50BC:722.00TC:722.33BC:721.83
TC:722.10BC:721.60
TC:724.50BC:724.00TC:724.50BC:724.00723.25723.75723.75723.75
TC:721.20BC:720.70
TC:720.70BC:720.20
TC:724.60BC:724.10TC:724.00BC:723.50
722.25723.20724.20724.90
UGS:744.50LGS:735.50
UGS:744.00LGS:735.80UGS:746.60LGS:735.80UGS:745.30LGS:735.50
720.50720.30
724.25
732.00732.50731.00731.50
733.00
721.50722.00TC:722.50BC:722.00TC:722.00BC:721.50TC:722.50BC:722.00
TC:721.50BC:721.00721.50
±725.30±725.30±725.30±725.30±725.30
735.00
735.00±735.40
TC:725.10BC:724.60TC:725.10BC:724.60TC:725.10BC:724.60TC:725.10BC:724.60TC:723.70BC:723.20TC:725.50BC:725.00 TC:720.50BC:720.00
734.10
TC:721.40BC:720.90
721.00721.50
±721.50±721.50TC:721.50BC:721.00
TC:720.50BC:720.00±721.50
±721.50722.00
TC:722.00BC:721.50
TC:722.00BC:721.50
TC:720.75BC:720.25
±722.70±722.70±722.70
TC:724.60BC:724.10TC:723.90BC:723.40TC:724.50BC:724.00TC:724.60BC:724.10
721.50
725.00725.00723.00±722.70
735.00
TC:722.25BC:721.75TC:721.75BC:721.25
±725.30
±735.40±735.40
724.50
TC:725.50BC:725.00
TC:725.50BC:725.00724.50TC:725.50BC:725.00724.50TC:724.80BC:724.30TC:725.00BC:724.50TC:725.50BC:725.00
725.75
TC:725.50BC:725.00
±735.40UGS:735.30LGS:732.60UGS:735.30LGS:733.00
ADDITIONAL STORM DRAINAGEINFRASTRUCTURE CONTINGENTON DESIGN OF COURTYARDSEGMENTAL BLOCKRETAINING WALL(DESIGN BY OTHERS)
APPROXIMATECENTERLINE OFEXISTING STREAM
APPROXIMATE CENTERLINE OFEXISTING INTERMITTENT STREAM
CONTRACTOR TO WATERPROOFALONG EXPOSED BUILDING FACE
CONTRACTOR TO WATERPROOFALONG EXPOSED BUILDING FACE
BILLBOARD TO REMAIN, CONTRACTOR TOCOORDINATE WITH LAMAR ADVERTISING COMPANYFOR FILL SLOPE AROUND BASE OF STRUCTURE
50' CONSTRUCTIONBUFFER (TYP.)50' CONSTRUCTIONBUFFER (TYP.)
50' CONSTRUCTIONBUFFER (TYP.)50' CONSTRUCTIONBUFFER (TYP.)
C6.0GRADINGPLANA10/14/22 02/16/23B D03/27/23 F04/12/23 05/17/23IJ06/02/23
COPYRIGHT c SEAMON, WHITESIDE & ASSOCIATES, INC.THIS DRAWING SHALL NOT BE REPRODUCED IN ANY MANNER OR USED FOR ANY PURPOSE WITHOUT WRITTEN PERMISSION.
GR4714DBLM/CS10/14/22DATE:
501 WANDO PARK BOULEVARD, SUITE 200 | MOUNT PLEASANT, SC 29464 | 508 RHETT STREET, SUITE 101 | GREENVILLE, SC 29601
500 W MAIN STCITY OF SPARTANBURG, SOUTH CAROLINACOKE FACILITYREDEVELOPMENT PHASE 1REVISION HISTORYDRAWN BY:CHECKED BY:SW+ PROJECT:
MOUNT PLEASANT, SC843.884.1667GREENVILLE, SC864.298.0534
WWW.SEAMONWHITESIDE.COMSUMMERVILLE, SC843.972.0710SPARTANBURG, SC864.272.1272CHARLOTTE, NC980.312.54506/1/23
153060SCALE: 1" = 30'0
SEWN R
Know what'sbelow.before you dig.CallFOR NOTES AND LEGEND,SEE SHEET C1.1
TC:750.00BC:750.00EX. TC:750.00EX. BC:750.00EXISTING TOP OF CURB ELEVATIONEXISTING BOTTOM OF CURB ELEVATIONUGS:750.00LGS:750.00UPPER GROUND SHOT (AT RETAINING WALL)LOWER GROUND SHOT (AT RETAINING WALL)RIDGE LINETOP OF CURB ELEVATIONBOTTOM OF CURB ELEVATION
DUKE DISTRIBUTION LINE NOTE:CONTRACTOR/OWNER TO COORDINATE RELOCATION/REMOVAL OFDUKE ENERGY DISTRIBUTION LINES WITH DUKE ENERGY.NOTE: SPOTS ALONG CURB & GUTTERINDICATE BOTTOM OF CURB ELEVATIONUNLESS SPECIFIED OTHERWISE IN THIS PLAN.CATCH BASIN (CB)JUNCTION BOX (JB)
SCDOT CURB INLET TYPE-16 (CI-16)STORM STRUCTURE LEGEND
PRECAST CONCRETE HEADWALL (HW)
SEE SHEET C7.0 FOR DETAILED DRAINAGE INFORMATION.SURFACE TRACKING NOTE:CONTRACTOR TO TRACK ALL SLOPES AFTER INSTALLATION. SEESURFACE TRACKING DETAILUTILITY NOTE:CONTRACTOR TO FIELD LOCATE ALL EXISTING UTILITIES BEFORESTARTING WORK AND REPORT ANY DISCREPANCIES TO THEENGINEER.GENERAL SITE NOTE:REFERENCE ARCHITECT PLANS (BY MCMILLAN PAZDAN SMITHARCHITECTURE) FOR ALL INFORMATION RELATED TO SITEINFORMATION, SITE GRADING, AND ALL UTILITY INFORMATIONLOCATED IN THE AMENITY AREAS. THE CONTRACTOR SHALL TAKEADEQUATE PRECAUTIONS PRIOR TO CONSTRUCTION TO ADDRESSANY DISCREPANCIES IN THE DRAWINGS AND SHALL REPORTDISCREPANCIES IMMEDIATELY.
RETAINING WALL NOTE:CONTRACTOR TO COORDINATE AND PREPARERETAINING WALL DESIGNS. ALL RETAINING WALLS 48"IN HEIGHT AND GREATER ARE TO BE PERMITTEDTHROUGH CITY OF SPARTANBURG BUILDING CODES.EXISTING UTILITY NOTE:THE LOCATION OF EXISTING UNDERGROUND UTILITIES ARESHOWN IN AN APPROXIMATE WAY ONLY AND HAVE NOT BEENINDEPENDENTLY VERIFIED BY THE OWNER OR ITSREPRESENTATIVE. THE CONTRACTOR SHALL DETERMINE THEEXACT LOCATION OF ALL EXISTING UTILITIES BEFORECOMMENCING ANY WORK, AND AGREES TO BE FULLYRESPONSIBLE FOR ANY AND ALL DAMAGES WHICH MIGHTOCCUR DUE TO THE CONTRACTOR'S FAILURE TO EXACTLYLOCATE AND PRESERVE ANY AND ALL UNDERGROUND UTILITIES.COMBINATION CURB INLET (CI-1)WATERPROFFING NOTE:CONTRACTOR TO ENSURE WATERPROOFING ON ALLFOUNDATION AND BUILDING WALLS FOR EXISTINGAND PROPOSED BUILDINGS.STANDARD GRADING PLAN NOTES:1.FOR PROJECT SURVEY INFORMATION INCLUDING VERTICAL DATUM AND BENCHMARK LOCATIONS, SEE“PROJECT SURVEY INFORMATION AND CONTRACTOR VERIFICATION REQUIREMENTS” ON SHEET C1.0.2.PRIOR TO STARTING CONSTRUCTION, THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING EXISTINGCONDITIONS, INCLUDING BUT NOT LIMITED TO TOPOGRAPHIC, TREE, STORM DRAINAGE FACILITIES, AND ALLUTILITIES. EXISTING UTILITIES SHOWN ARE APPROXIMATE AND HAVE NOT BEEN INDEPENDENTLY VERIFIEDBY THE OWNER OR ENGINEER. THEREFORE, THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING THE EXACTVERTICAL AND HORIZONTAL LOCATIONS OF ALL EXISTING UTILITIES. ANY DISCREPANCIES OR CONFLICTSIDENTIFIED DURING VERIFICATION OF EXISTING CONDITIONS AND UTILITIES SHALL BE REPORTED TO THEOWNER AND ENGINEER. ANY COSTS ASSOCIATED WITH CORRECTIVE WORK OR DAMAGES THAT ARE ARESULT OF THE CONTRACTOR NOT VERIFYING EXISTING CONDITIONS AND THE EXACT VERTICAL ANDHORIZONTAL LOCATION OF ALL EXISTING UTILITIES WILL BE THE CONTRACTOR'S RESPONSIBILITY.3.REFER TO THE “SPOT ELEVATION KEY” FOR INFORMATION ON SPOT ELEVATIONS.4.COORDINATE WITH THE OWNER AND THE PROJECT GEOTECHNICAL CONSULTANT FOR LOT FILLCOMPACTION AND TESTING REQUIREMENTS.5.CONTRACTOR TO SELF-VERIFY THAT SITE GRADES, PONDS, POND DIKES, DRAINAGE PIPES, AND DRAINAGESTRUCTURES ARE CONSTRUCTED PER THE PLANS PRIOR TO REQUESTING FINAL AS-BUILT SURVEY FROMSURVEYOR.SITE GRADING NOTES: 1.CONTRACTOR SHALL PITCH GRADE EVENLY BETWEEN SPOT GRADES.2.WHERE NEW PAVING MEETS EXISTING PAVING, CONTRACTOR SHALL MEET LINE AND GRADE OF EXISTING.3.CONTRACTOR SHALL PROVIDE POSITIVE DRAINAGE AWAY FROM FACE OF BUILDINGS AT ALL LOCATIONS.4.ALL PROPOSED TOP OF CURB ELEVATIONS ARE SIX INCHES (6") ABOVE BOTTOM OF CURB ELEVATIONSUNLESS SHOWN OTHERWISE.5.CONTRACTOR SHALL BLEND NEW EARTHWORK SMOOTHLY INTO EXISTING EARTHWORK.6.THE CONTRACTOR SHALL VERIFY ALL EXISTING GRADES IN THE FIELD AND REPORT ANY DISCREPANCIESIMMEDIATELY TO THE ENGINEER PRIOR TO STARTING WORK.7.REFER TO GEOTECHNICAL REPORT FOR SPECIFIC EXCAVATION AND BACKFILL REQUIREMENTS.8.HANDICAP PARKING SPACES AND ACCESS AISLES SHALL BE GRADED WITH THE SLOPE NOT TO EXCEED 2.0%IN ANY DIRECTION.9.WALKWAYS AND CROSSWALKS SHALL BE GRADED WITH A CROSS-SLOPE OF 2.0% AND RUNNING SLOPE OF5% MAXIMUM.10.ALL EXISTING AND PROPOSED MANHOLE FRAMES, GRATES, COVERS, VALVES, CLEANOUTS, CASTINGS, ETC.SHALL BE RAISED TO FINISHED GRADE PRIOR TO FINAL GRADING AND PAVEMENT CONSTRUCTION.11.CONTRACTOR SHALL TOP DRESS FINAL 4 INCHES TO FINISH GRADE WITH CLEAN SCREENED TOPSOIL PRIORTO SEEDING IN ALL VEGETATED AREAS. CONTRACTOR SHALL REFERENCE LANDSCAPE ARCHITECT PLANSFOR ALL SEEDING REQUIREMENTS.
720720725
705710715720
735
740730735740
720725730
735
720725730
735
735740
740
745
745
750
750
725725 730 735
720
725
725
725730735
740
745725730735740745
720
725
730
715
735725730
715720725730735
725730735
725
730
720
723723 733S
S
S
D
D
D DD
DWSOWSOWSOHYDGSO
G
DD
G
S
S
D
MONK STR/W UNKNOWN
OXFORD RD50' R/W PER PB 175 PG 56
W MAIN STSC HWY 2975' R/W PER PB 175 PG 56
INTERMITTENTSTREAM 1 (CONT.)
PERENNIALSTREAM 1(CONT.) S
INTERMITTENTSTREAM 1105 LF
~ASPHALT~
~ASPHALT~D E
724
735739725730
720721
722722
723 723
721
721
721EXISTINGWAREHOUSEBUILDINGEX. FFE: ±724.8
EXISTINGWAREHOUSEBUILDINGEX. FFE: ±722.7EX. FFE: ±725.3
EX. FFE: ±735.4
EXISTING DOCK
EX. FFE: ±735.4EXISTING COKE BUILDING
724
736737735730725724
725
723
724
734733732
724724
721
722723724
726727728729
724
723
721722723
722723724
721721723724723724
722722
722
722
724
725
725
725725725
725
724723724
724
723725
LOWER EXISTINGGRATE TOELEVATION 734.10
D01 (CI-1)RIM:720.75IE OUT:716.75IE IN: 716.50
YI
C01.1 (DBL CI-1)RIM:722.25IE OUT:718.50 (C01)72LF-18" RCP@ 1.25%
C01 (CI-1)RIM:723.20IE IN:717.60 (C01.1)IE IN:718.60 (C02)IE OUT:717.50 (A04)A05 (CI-1)RIM:722.00IE IN:716.10 (A05.1)IE IN:716.10 (A05.2)IE OUT:716.00 (A04)
94LF-18" RCP@ 1.06%
81LF-18" RCP@ 2.97%A04 (CI-1)RIM:723.00IE IN:715.25 (A05)IE IN:716.50 (C01)IE OUT:714.75 (A03)56LF-18" RCP@ 1.34%
A01 (HW)IE OUT:711.50 (A02)
B02 (CI-1)RIM:720.00IE IN:715.60 (B03)IE IN:715.60 (B02.1)IE OUT:715.50 (B01)C02 (CI-1)RIM:723.40IE OUT:719.50 (C01)
85LF-18" RCP@ 1.06%
40LF-30" RCP@ 1.26%52LF-24" RCP@ 1.44%
B03 (CI-1)RIM:722.00IE OUT:718.00 (B02)
A02 (3K BAYSEPARATORWATER QUALITY UNIT)RIM:722.33IE IN:712.00 (A03)IE OUT:712.00 (A01)25LF-30" RCP@ 2.00%A03 (JB)RIM:721.90IE IN:714.00 (A04)IE IN:712.75 (B01)IE OUT:712.50 (A02)
65LF-18" RCP@ 1.31%B02.1 (CI-1)RIM:720.00IE OUT:716.00 (B02)42LF-18" RCP@ 0.96%
A05.1 (CI-1)RIM:720.20IE OUT:716.50 (A05)49LF-18" RCP@ 0.82%
A05.2 (CB)RIM:723.50IE IN:719.00 (A05.3)IE OUT:718.50 (A05)106LF-18" RCP@ 2.27%
B01 (CB)RIM:720.30IE IN:713.70 (B02)IE OUT:713.60 (A03)
164LF-18" RCP @ 1.10%
A05.3 (YI)RIM:722.10IE OUT:719.60 (A05.2)69LF-12" HDPE@ 0.87%ROOF DRAIN COLLECTOR PIPE TOBE COORDINATED WITH EXISTINGBUILDING ROOF DRAINAGE
EXISTING STORM MANHOLETO REMAIN. ADJUST RIM TOPROPOSED GRADE.
EXISTING STORM STRUCTURES TOREMAIN. TOP TO BE REMOVED ANDSTRUCTURE COVERED & SEALEDBEFORE PAVEMENT INSTALLATION.
ADDITIONAL STORM DRAINAGEINFRASTRUCTURE IN COURTYARDWILL BE ROUTED THROUGHPROPOSED STORM LINE A
EXISTING STORM DRAIN LINEUNDER BUILDING TO REMAIN
LIMITS OF EXISTINGSTORM DRAIN NOTSHOWN ON SURVEYEXISTING STORMDRAIN TO REMAIN
EXISTING STORM INLET TOREMAIN. ADJUST GRATETO PROPOSED GRADE.
EXISTING STORM STRUCTURE TO REMAIN. TOP TO BE REMOVED ANDSTRUCTURE COVERED & SEALED BEFORE PAVEMENT INSTALLATION.STRUCTURE INVERT NOT INCLUDED IN SURVEY. IN CASE OFDISCREPANCIES REPORT INVERT TO ENGINEER IMMEDIATELY.
25'PROPOSED 25'SANITARY SEWEREASEMENT
25'EXISTING 25' SANITARYSEWER EASEMENT
50' CONSTRUCTIONBUFFER (TYP.)50' CONSTRUCTIONBUFFER (TYP.)
50' CONSTRUCTIONBUFFER (TYP.)50' CONSTRUCTIONBUFFER (TYP.)
C7.0DRAINAGEPLANA10/14/22 02/16/23B D03/27/23 F04/12/23 05/17/23IJ06/02/23
COPYRIGHT c SEAMON, WHITESIDE & ASSOCIATES, INC.THIS DRAWING SHALL NOT BE REPRODUCED IN ANY MANNER OR USED FOR ANY PURPOSE WITHOUT WRITTEN PERMISSION.
GR4714DBLM/CS10/14/22DATE:
501 WANDO PARK BOULEVARD, SUITE 200 | MOUNT PLEASANT, SC 29464 | 508 RHETT STREET, SUITE 101 | GREENVILLE, SC 29601
500 W MAIN STCITY OF SPARTANBURG, SOUTH CAROLINACOKE FACILITYREDEVELOPMENT PHASE 1REVISION HISTORYDRAWN BY:CHECKED BY:SW+ PROJECT:
MOUNT PLEASANT, SC843.884.1667GREENVILLE, SC864.298.0534
WWW.SEAMONWHITESIDE.COMSUMMERVILLE, SC843.972.0710SPARTANBURG, SC864.272.1272CHARLOTTE, NC980.312.54506/1/23
153060SCALE: 1" = 30'0
SEWN R
Know what'sbelow.before you dig.CallFOR NOTES AND LEGEND,SEE SHEET C1.1
CATCH BASIN (CB)JUNCTION BOX (JB)
SCDOT CURB INLET TYPE-16 (CI-16)STORM STRUCTURE LEGEND
PRECAST CONCRETE HEADWALL (HW)
EXISTING UTILITY NOTE:THE LOCATION OF EXISTING UNDERGROUND UTILITIES ARESHOWN IN AN APPROXIMATE WAY ONLY AND HAVE NOT BEENINDEPENDENTLY VERIFIED BY THE OWNER OR ITSREPRESENTATIVE. THE CONTRACTOR SHALL DETERMINE THEEXACT LOCATION OF ALL EXISTING UTILITIES BEFORECOMMENCING ANY WORK, AND AGREES TO BE FULLYRESPONSIBLE FOR ANY AND ALL DAMAGES WHICH MIGHTOCCUR DUE TO THE CONTRACTOR'S FAILURE TO EXACTLYLOCATE AND PRESERVE ANY AND ALL UNDERGROUND UTILITIES.COMBINATION CURB INLET (CI-1)ROOF DRAIN NOTE: PROVIDE MANUFACTURED ADAPTER, BY GUTTERSYSTEM PROVIDER, TO CONNECT DOWNSPOUT TOUNDERGROUND ROOF DRAIN PIPE. PROVIDEMANUFACTURER'S DATA SHEET FOR APPROVALBEFORE INSTALLATION. CONTRACTOR TO ENSUREALL ROOF DRAINS HAVE A MINIMUM 2' COVER WITH AMINIMUM OF 1% SLOPE.STORM DRAIN NOTE: THE STORM DRAINAGE SHOWN IN THIS SHEET HAS NOT BEEN SIZED. THE SIZES SHOWN ARE ANESTIMATE FOR THE PURPOSE OF SCHEMATIC PRICING ONLY.NOTE1.ALL STORM DRAINAGE IS TO BE FITTED WITH WATERTIGHT JOINTS.2.PIPE LENGTHS ARE MEASURED TO CENTER OF DRAINAGE STRUCTURE ANDROUNDED TO NEAREST WHOLE FOOT INCREMENT.3.CONTRACTOR TO TOP DRESS FINAL 4" TO FINISH GRADE WITH CLEAN SCREENEDTOPSOIL PRIOR TO SEEING IN ALL VEGETATED AREAS.4.CONTRACTOR TO PROVIDE DESIGN ENGINEER WITH AS-BUILT SURVEY OF STORMDRAINAGE IMPROVEMENTS, INCLUDING STORM WATER MANAGEMENT POND ALONGWITH OUTLET CONTROL STRUCTURE AND CONVEYANCE SYSTEM, FOR REVIEW ASPART OF CLOSE OUT PROCESS.ROOF DRAIN NOTE: CONTRACTOR TO ENSURE ALL ROOF DRAINS HAVEA MINIMUM 2' COVER WITH A MINIMUM OF 1% SLOPE.ROOF DRAIN ALLOWANCE NOTE: CONTRACTOR TO INCLUDE ALLOWANCE FOR ROOF DRAIN COLLECTORS AROUNDBUILDING FOR SCHEMATIC PRICING.
STORM_A PROFILE700705710715720725730
700705710715720725730
-0+50EG:FG:0+00EG:704.73FG:EG:722.89FG:722.331+00EG:722.61FG:721.86EG:721.21FG:723.002+00EG:FG:2+33.65EG:FG:A05.1 PROFILE710715720725730
710715720725730
52LF-24" RCP@ 1.44%56LF-18" RCP@ 1.34%
25LF-30" RCP@ 2.00%40LF-30" RCP@ 1.26%
A05.2 PROFILE710715720725730
710715720725730
-0+20EG:FG:0+00EG:720.65FG:722.00EG:FG:0+68.92EG:FG:-0+20EG:FG:0+00EG:720.65FG:722.00EG:720.26FG:723.111+00EG:725.84FG:723.78EG:724.42FG:724.081+94.66EG:FG:
49LF-18" RCP@ 0.82%
106LF-18" RCP@ 2.27%
A03RIM:721.90IE IN:714.00 (A04)IE IN:712.75 (B01)IE OUT:712.50 (A02)
A01RIM:714.38IE OUT:711.50
A05RIM:722.00IE IN:716.10 (A05.1)IE IN:716.10 (A05.2)IE OUT:716.00 (A04)A05.1RIM:720.20IE OUT:716.50 (A05)
A05RIM:722.00IE IN:716.10 (A05.1)IE IN:716.10 (A05.2)IE OUT:716.00 (A04)
A05.2RIM:723.50IE IN:719.00 (A05.3)IE OUT:718.50 (A05)
A02RIM:722.33IE IN:712.00 (A03)IE OUT:712.00 (A01)A04RIM:723.00IE IN:715.25 (A05)IE IN:716.50 (C01)IE OUT:714.75 (A03)A05RIM:722.00IE IN:716.10 (A05.1)IE IN:716.10 (A05.2)IE OUT:716.00 (A04)
69LF-12" HDPE@ 0.87%A05.3RIM:722.10IE OUT:719.60 (A05.2)
STORM_B PROFILE700705710715720725730
700705710715720725730
-0+50EG:FG:0+00EG:722.84FG:721.90EG:721.42FG:720.651+00EG:720.62FG:721.16EG:720.83FG:721.142+00EG:720.95FG:720.96EG:722.08FG:720.623+00EG:723.14FG:722.01EG:FG:3+59.31EG:FG:STORM_B01.1 PROFILE710715720725
710715720725
81LF-18" RCP@ 2.97%
65LF-18" RCP@ 1.31%
-0+20EG:FG:0+00EG:721.70FG:720.00EG:FG:0+61.54EG:FG:42LF-18" RCP@ 0.96%
164LF-18" RCP@ 1.10%
B03RIM:722.00IE OUT:718.00 (B02)
B02RIM:720.00IE IN:715.60 (B03)IE IN:715.60 (B02.1)IE OUT:715.50 (B01)
A03RIM:721.90IE IN:714.00 (A04)IE IN:712.75 (B01)IE OUT:712.50 (A02)
B02RIM:720.00IE IN:715.60 (B03)IE IN:715.60 (B02.1)IE OUT:715.50 (B01)B02.1RIM:720.00IE OUT:716.00 (B02)
B01RIM:720.30IE IN:713.70 (B02)IE OUT:713.60 (A03)
STORM_C PROFILE710715720725730
710715720725730
-0+50EG:FG:0+00EG:721.95FG:723.00EG:722.81FG:724.001+00EG:724.15FG:723.37EG:725.08FG:724.002+00EG:FG:2+28.86EG:FG:
94LF-18" RCP@ 1.06%
85LF-18" RCP@ 1.06%C01RIM:723.20IE IN:717.60 (C01.1)IE IN:718.60 (C02)IE OUT:717.50 (A04)
A04RIM:723.00IE IN:715.25 (A05)IE IN:716.50 (C01)IE OUT:714.75 (A03)
C02RIM:723.40IE OUT:719.50 (C01)
STORM_C01.1 PROFILE710715720725730
710715720725730
-0+20EG:FG:0+00EG:723.98FG:723.20EG:725.41FG:723.270+99.06EG:FG:
72LF-18" RCP@ 1.25%C01RIM:723.20IE IN:717.60 (C01.1)IE IN:718.60 (C02)IE OUT:717.50 (A04)C01.1RIM:722.25IE OUT:718.50 (C01)
C7.1DRAINAGEPROFILES 02/16/23B D03/27/23 F04/12/23 05/17/23IJ06/02/23
COPYRIGHT c SEAMON, WHITESIDE & ASSOCIATES, INC.THIS DRAWING SHALL NOT BE REPRODUCED IN ANY MANNER OR USED FOR ANY PURPOSE WITHOUT WRITTEN PERMISSION.
GR4714DBLM/CS10/14/22DATE:
501 WANDO PARK BOULEVARD, SUITE 200 | MOUNT PLEASANT, SC 29464 | 508 RHETT STREET, SUITE 101 | GREENVILLE, SC 29601
500 W MAIN STCITY OF SPARTANBURG, SOUTH CAROLINACOKE FACILITYREDEVELOPMENT PHASE 1REVISION HISTORYDRAWN BY:CHECKED BY:SW+ PROJECT:
MOUNT PLEASANT, SC843.884.1667GREENVILLE, SC864.298.0534
WWW.SEAMONWHITESIDE.COMSUMMERVILLE, SC843.972.0710SPARTANBURG, SC864.272.1272CHARLOTTE, NC980.312.54506/1/23
204080SCALE: 1" = 40'0.0'01.0'2.0'4.0'SCALE: 1" = 4.0'R
Know what'sbelow.before you dig.Call
S
S
S
D
D
D DD
DWSOWSOWSOHYDGSO
G
DD
G
S
D
MONK STR/W UNKNOWN
OXFORD RD50' R/W PER PB 175 PG 56
W MAIN STSC HWY 2975' R/W PER PB 175 PG 56
N/F: MARSHALL CLARK ET ALTMS: 7-12-13-048.00DB 127-M PG 659PB 2 PG 71-72
N/F: STEPHEN WASHINGTONTMS: 7-12-13-042.00DB 122-L PG 874
N/F: CAROLINA INS& INVESTMENT COTMS: 7-12-13-041.00DB 33-D PG 495
N/F: KAPASI INVESTMENTS, LLCTMS: 7-12-13-040.00DB 93-Q PG 778PB 165 PG 738N/F: JAMES & LYNN FLYNNTMS: 7-12-13-035.00DB 75-U PG 533PB 177 PG 568
N/F: NEW LIFE MINISTRIESCHURCH OF SPARTANBURGTMS: 7-12-13-038.00DB 70-T PG 575PB 29 PG 52
N/F: SPANN VENTURES LLCTMS: 7-12-13-037.00DB 124-A 569PB 10 PG 100
N/F: MARSHALL CLARK ET ALTMS: 7-12-13-047.00DB 127-M PG 659PB 2 PG 71-72
N/F: JBURKE INVESTMENTS LLCTMS: 7-12-13-020.00DB 124-Z PG 405PB 25-266
INTERMITTENTSTREAM 1 (CONT.)
PERENNIALSTREAM 1(CONT.) S
INTERMITTENTSTREAM 1105 LF
~ASPHALT~
~ASPHALT~D E
YI
50' CONSTRUCTIONBUFFER (TYP.)50' CONSTRUCTIONBUFFER (TYP.)
50' CONSTRUCTIONBUFFER (TYP.)50' CONSTRUCTIONBUFFER (TYP.)
CONSTRUCTION BUFFER
APPROXIMATE CENTERLINE OFJURISDICTIONAL STREAM AS INDICATED INEAS WETLAND DELINEATION REPORT,DATED APRIL 1, 2022.
APPROXIMATE CENTERLINE OFJURISDICTIONAL STREAM AS INDICATED INEAS WETLAND DELINEATION REPORT,DATED APRIL 1, 2022.20'
20'
82.1'
EXISTING 6" WATER MAIN(MAINTAINED BYSPARTANBURG WATER)EXISTING 6" WATER MAIN(MAINTAINED BYSPARTANBURG WATER)SEE WATERUTILITY SCHEDULE
PUBLIC FIRE HYDRANTASSEMBLY (TYP.)GATE VALVE (TYP.)TS&V ON EXISTING6" WATER MAIN
GATE VALVE (TYP.)TS&V ONEXISTING 6"WATER MAINPUBLIC FIRE HYDRANTASSEMBLY (TYP.)
EXISTING PUBLIC FIREHYDRANT ASSEMBLY6" DIP
SPARTANBURG WATER APPROVED (LEADFREE) IRRIGATION DOUBLE CHECK VALVEASSEMBLY BACK FLOW PREVENTER ANDBOX, BY CONTRACTOR. IT IS THECONTRACTOR'S RESPONSIBILITY FORSIZING OF IRRIGATION BFP.CONTINUATION, DESIGN ANDINSTALLATION OF IRRIGATION SYSTEM(AFTER THE BFP) IS THERESPONSIBILITY OF THE CONTRACTOR.
SPARTANBURG WATER TO INSTALLIRRIGATION METER. CONTRACTOR TOCOORDINATE WITH SPARTANBURG WATERNEW CONNECTIONS (864-583-7361). IT ISTHE CONTRACTOR'S RESPONSIBILITY FORTHE SIZING OF IRRIGATION METER.SPARTANBURG WATER TO INSTALL IRRIGATION TAPON EXISTING 6" WATER MAIN. SPARTANBURG WATERTO INSTALL IRRIGATION SERVICE LINE. CONTRACTORTO COORDINATE WITH SPARTANBURG WATER NEWCONNECTIONS (864-583-7361). IT IS THECONTRACTOR'S RESPONSIBILITY FOR DESIGN ANDSIZING OF THE IRRIGATION LINE.
2" SCHEDULE 40 PVCDOMESTIC SERVICE LINE
2" SCHEDULE 40 PVCDOMESTIC SERVICE LINESEE FIRE PROTECTIONSCHEDULE
SEE FIRE PROTECTION SCHEDULE
20' SPARTANBURGWATER EASEMENT
20' SPARTANBURGWATER EASEMENT
SEE DOMESTIC WATERUTILITY SCHEDULE
SEE WATERUTILITY SCHEDULE2" SCHEDULE 40 PVCDOMESTIC SERVICE LINESEE FIRE PROTECTIONSCHEDULESEE FIRE PROTECTIONSCHEDULE
64.9'
SPARTANBURG WATER TO INSTALL FOUNTAIN TAPON EXISTING 6" WATER MAIN. SPARTANBURG WATERTO INSTALL FOUNTAIN SERVICE LINE. CONTRACTORTO COORDINATE WITH SPARTANBURG WATER NEWCONNECTIONS (864-583-7361). IT IS THECONTRACTOR'S RESPONSIBILITY FOR DESIGN ANDSIZING OF THE FOUNTAIN LINE.
CONTINUATION, DESIGN ANDINSTALLATION OF FOUNTAIN SYSTEM(AFTER THE BFP) IS THERESPONSIBILITY OF THE CONTRACTOR.FOUNTAIN DESIGNER TO COORDINATEWITH SWS NEW CONNECTIONS FORRPZ REQUIREMENTS.SPARTANBURG WATER TO INSTALLMETER. CONTRACTOR TO COORDINATEWITH SPARTANBURG WATER NEWCONNECTIONS (864-583-7361). IT IS THECONTRACTOR'S RESPONSIBILITY FOR THESIZING OF FOUNTAIN METER.SPARTANBURG WATER APPROVED BACK FLOWPREVENTER AND BOX, BY CONTRACTOR. IT ISTHE CONTRACTOR'S RESPONSIBILITY FORSIZING OF BFP.
29.7'INTERIOR STAND PIPEAND B/F LOCATIONPER ARCHITECT ANDMEP PLANS
INTERIOR STAND PIPEAND B/F LOCATIONPER ARCHITECT ANDMEP PLANS
INTERIOR STAND PIPEAND B/F LOCATIONPER ARCHITECT ANDMEP PLANSEXISTING BUILDING(PROPOSED RESTAURANT)EXISTING BUILDING(PROPOSED GYM)EXISTING FACILITY(PROPOSED MIXED-USE)
CONSTRUCTION BUFFER
TYPICAL DOMESTIC WATER METER ANDBACKFLOW PREVENTER ASSEMBLY SCHEDULENOT TO SCALE
WATER SIZING NOTE: IT IS ASSUMED THAT THE DOMESTIC METERREQUIRED WILL BE LESS THAN 2" IN SIZE(SPARTANBURG WATER WILL INSTALL UP TO 2"IN SIZE). IF IT TURNS OUT THAT THE REQUIREDMETER AND LINE SIZE IS GREATER THAN 2" INSIZE, THE CONTRACTOR WILL BE RESPONSIBLEFOR THE TAP AND METER INSTALLATION (ASOPPOSED TO NOTES SHOWN ON THIS PLAN).THE CONTRACTOR WILL ALSO BE RESPONSIBLEFOR SUBMITTAL TO AND COORDINATION WITHSPARTANBURG WATER (METERS LARGER THAN2" REQUIRE LARGE METER PROJECT SUBMITTALTO SPARTANBURG WATER ENGINEERING).SPARTANBURG WATER TO INSTALL 2"DOMESTIC TAP ON EXISTING 6" WATER MAIN.CONTRACTOR TO COORDINATE WITHSPARTANBURG WATER NEW CONNECTIONSSPARTANBURG WATER TOINSTALL 2" DOMESTIC METER.CONTRACTOR TO COORDINATEWITH SPARTANBURG WATERNEW CONNECTIONSSPARTANBURG WATERTO INSTALL 2" DOMESTICSERVICE LINECONTRACTOR TO INSTALLSPARTANBURG WATERAPPROVED (LEAD FREE)BACKFLOW PREVENTER AND BOX2" DOMESTIC SERVICELINE (SEE MEP PLANS,DESIGN BY OTHERSFOR CONTINUATIONINTO BUILDING)CONTRACTOR TO INSTALL2" DOMESTIC SERVICELINE TO BACKFLOW
TYPICAL FIRE PROTECTION AND REMOTE FDC SCHEDULENOT TO SCALE5" STORZ REMOTE FIREDEPARTMENTCONNECTION (FDC)
6" FIRE PROTECTIONSERVICE (SEE MEP PLANS,DESIGN BY OTHERS FORCONTINUATION INTOBUILDING)CONTRACTOR TO INSTALL 6" DIPFIRE SERVICE LINE TO 1' ABOVE FFE.SEE DETAIL AND REFERENCE MEPPLANS FOR CONTINUATION OF FIRESERVICE INSIDE OF BUILDING (TYP.)CONTRACTOR TO INSTALL SWS APPROVED6" DOUBLE CHECK DETECTOR ASSEMBLYBACKFLOW PREVENTER INSIDE BUILDING.SEE DETAIL AND REFERENCE MEP PLANSFOR CONTINUATION OF FIRE SERVICEINSIDE BUILDING (TYP.)(DESIGN BY OTHERS)6" DIP FIRE SERVICE LINE, TO BEINSTALLED BY CONTRACTOR.CONTRACTOR TO CONFIRM FIRE LINESIZE WITH FIRE SPRINKLER DESIGNER.COORDINATE WITH CIVIL AS REQUIRED.CONTRACTOR TO INSTALL 6"X6" TAPPINGSADDLE AND VALVE ON EXISTING 6"WATER MAIN (CONTRACTOR TO FIELDVERIFY LOCATION). IT IS CONTRACTOR'SRESPONSIBILITY TO PREPARE PIT FORTAP. CONTRACTOR TO COORDINATE TAPWITH SPARTANBURG WATER.C8.0UTILITY PLAN- WATERA10/14/22H05/04/2302/16/23BC02/21/23D03/27/23E03/30/23F04/12/23 05/17/23IJ06/02/23
COPYRIGHT c SEAMON, WHITESIDE & ASSOCIATES, INC.THIS DRAWING SHALL NOT BE REPRODUCED IN ANY MANNER OR USED FOR ANY PURPOSE WITHOUT WRITTEN PERMISSION.
GR4714DBLM/CS10/14/22DATE:
501 WANDO PARK BOULEVARD, SUITE 200 | MOUNT PLEASANT, SC 29464 | 508 RHETT STREET, SUITE 101 | GREENVILLE, SC 29601
500 W MAIN STCITY OF SPARTANBURG, SOUTH CAROLINACOKE FACILITYREDEVELOPMENT PHASE 1REVISION HISTORYDRAWN BY:CHECKED BY:SW+ PROJECT:
MOUNT PLEASANT, SC843.884.1667GREENVILLE, SC864.298.0534
WWW.SEAMONWHITESIDE.COMSUMMERVILLE, SC843.972.0710SPARTANBURG, SC864.272.1272CHARLOTTE, NC980.312.54506/1/23
153060SCALE: 1" = 30'0
SEWNR
Know what'sbelow.before you dig.CallFOR NOTES AND LEGEND,SEE SHEET C1.1
UTILITY LEGEND
EXISTING WATER LINEPROPOSED WATER LINE
EXISTING FIRE HYDRANTPROPOSED FIRE HYDRANTPROPOSED WATER VALVEPROPOSED IRRIGATION METER/BFPPROPOSED BFP
EXISTING SEWER LINEPROPOSED SEWER MAIN
EXISTING SEWER MANHOLEPROPOSED SEWER MANHOLEPROPOSED FIRE PROTECTION LINEPROPOSED WATER SERVICE LINE
PROPOSED SEWER SERVICE LINE
IRRIGATION SERVICE LINE BACK FLOW PREVENTER NOTE: CONTRACTOR IS RESPONSIBLE FOR THE INSTALLATION OF A SWSAPPROVED (LEAD FREE) DOUBLE CHECK VALVE ASSEMBLY BACKFLOW PREVENTER AND BOX AFTER IRRIGATION METER.CONTRACTOR TO COORDINATE WITH SPARTANBURG WATER NEWCONNECTIONS (864-583-7361). IT IS CONTRACTOR'S RESPONSIBILITYFOR IRRIGATION DESIGN AND METER/BACKFLOW SIZING.
IRRIGATION SERVICE LINE TAP NOTE: SPARTANBURG WATER WILL BE RESPONSIBLE FOR INSTALLING THEIRRIGATION TAP ON 6" WATER MAIN (AS SHOWN). SPARTANBURGWATER WILL ALSO BE RESPONSIBLE FOR ALL WORK REQUIRED FORBRINGING THE IRRIGATION WATER LINE TO THE WATER METER.SPARTANBURG WATER WILL ALSO INSTALL IRRIGATION WATERMETER AND BOX. CONTRACTOR IS TO COORDINATE IRRIGATIONSERVICE LINE AND METER INSTALLATION WITH SPARTANBURGWATER NEW CONNECTIONS (864-583-7361). IT IS CONTRACTOR'SRESPONSIBILITY FOR IRRIGATION DESIGN AND METER/BACKFLOWSIZING.
IRRIGATION SERVICE:CONTRACTOR RESPONSIBLE TO ENSURE THAT IRRIGATION SERVICELINES, VALVES, METER BOXES, ETC. WILL NOT BE INSTALLED WITHINPUBLIC RIGHT OF WAY.
SPARTANBURG WATER PRE-CONSTRUCTION CONFERENCE:A PRE-CONSTRUCTION CONFERENCE WITH SPARTANBURG WATER ISREQUIRED AT LEAST 72 HOURS IN ADVANCE OF THE START OFWATER AND SEWER WORK. CONTRACTOR IS TO COORDINATE WITHENGINEER (SEAMONWHITESIDE AT 864-298-0534) TO SET UP THEMEETING WITH SPARTANBURG WATER (AT SPARTANBURG WATEROFFICE AT 175 NORTH LIBERTY STREET). THE FOLLOWINGPERSONNEL ARE REQUIRED TO ATTEND THE CONFERENCE:1.SWS-SSSD PROJECT MANAGER/ STAFF ENGINEER2.SWS-SSSD INSPECTOR3.DESIGN ENGINEER (SEAMONWHITESIDE)4.CONTRACTOR AND ANY SUB-CONTRACTORSWATER AND SANITARY SEWER TESTING: 1.CONTRACTOR IS RESPONSIBLE FOR COORDINATING ANDPERFORMING ALL WATER AND SANITARY SEWER TESTINGTHAT IS REQUIRED BY SPARTANBURG WATER AND SCDHECBEFORE LINES ARE PUT INTO OPERATION.2.ALL INSTALLED MAINS MUST MEET SCDHEC TESTINGGUIDELINES AS PART OF THE CONDITIONS OF THE SCDHECCONSTRUCTION PERMIT BEFORE A PERMIT TO OPERATE WILLBE ISSUED BY SCDHEC.SPARTANBURG WATER TAP AND CAPACITY FEES NOTE: OWNER IS RESPONSIBLE FOR ALL TAP AND CAPACITY FEESREQUIRED BY SPARTANBURG WATER FOR THE INSTALLATION OF ALLWATER AND SEWER LINES. CONTRACTOR IS TO COORDINATE WITHOWNER AND SPARTANBURG WATER BEFORE STARTING WORK.
IRRIGATION SIZING NOTE: IT IS ASSUMED THAT THE IRRIGATION METER REQUIRED WILL BELESS THAN 2" IN SIZE (SPARTANBURG WATER WILL INSTALL UP TO 2"IN SIZE). IF IT TURNS OUT THAT THE REQUIRED METER AND LINE SIZEIS GREATER THAN 2" IN SIZE, THE CONTRACTOR WILL BERESPONSIBLE FOR THE IRRIGATION TAP AND METER INSTALLATION(AS OPPOSED TO NOTES SHOWN ON THIS PLAN). THE CONTRACTORWILL ALSO BE RESPONSIBLE FOR SUBMITTAL TO AND COORDINATIONWITH SPARTANBURG WATER (METERS LARGER THAN 2" REQUIRELARGE METER PROJECT SUBMITTAL TO SPARTANBURG WATERENGINEERING).THE IRRIGATION DESIGN AND INSTALLATION IS THE RESPONSIBILITYOF THE CONTRACTOR. CONTRACTOR TO COORDINATE WITHSPARTANBURG WATER.
SPARTANBURG WATER SPECIFICATIONS NOTE:CONTRACTOR IS RESPONSIBLE FOR ENSURING ALL WATER ANDSEWER INSTALLATION WORK ADHERES TO SPARTANBURG WATERSTANDARD SPECIFICATIONS.WATER MAIN AS-BUILT SURVEY:CONTRACTOR IS RESPONSIBLE FOR PROVIDING AN AS-BUILTSURVEY OF THE ENTIRE WATER SYSTEM TO THE ENGINEER AS PARTOF THE CONDITIONS OF SCDHEC CONSTRUCTION PERMIT.
FIRE SERVICE LINE BACK FLOW PREVENTER NOTE: CONTRACTOR IS RESPONSIBLE FOR THE INSTALLATION OF ASPARTANBURG WATER APPROVED (LEAD FREE) DOUBLE CHECKDETECTOR ASSEMBLY BACK FLOW PREVENTERS INSIDE BUILDINGS.CONTRACTOR TO COORDINATE BACK FLOW PREVENTERS WITHSPARTANBURG WATER PRIOR TO PURCHASE.STATE FIRE MARSHAL NOTES: 1.VALVES CONTROLLING THE WATER TO THE FIRE SPRINKLERSYSTEM (INCLUDING PIV'S AND VALVES IN THE BACKFLOWPREVENTER VAULT) MUST BE ELECTRONICALLY SUPERVISED INACCORDANCE WITH 2018 IBC 903.4. LOCKS ALONE ARE NOTEQUIVALENT. CONTRACTOR TO DEMONSTRATE COMPLIANCETO SPARTANBURG WATER.2.PER 2019 NFPA 24-5.4.2, BACKFLOW PREVENTER DEVICES MUSTBE LISTED FOR FIRE PROTECTION SERVICE. CONTRACTOR TODEMONSTRATE COMPLIANCE TO SPARTANBURG WATER.
REMOTE FIRE DEPARTMENT CONNECTION (FDC) NOTE: 1.CONTRACTOR TO INSTALL 5" STORZ FITTING AT REMOTE FIREDEPARTMENT CONNECTION (FDC) AS SHOWN ON PLANS.CONTRACTOR TO CONFIRM COMPLIANCE WITH CITY OFSPARTANBURG BUILDING DEPARTMENT.2.CONTRACTOR SHALL REFER TO FIRE SPRINKLER DRAWINGSFOR FDC DETAIL AND RISER ROOM CONFIGURATION.3.ALL CURBING IN FRONT OF SITE FIRE PROTECTION SERVICES(REMOTE FDC AND FIRE HYDRANTS) SHALL BE BE PAINTED REDWITH NO PARKING IN WHITE TEXT ALONG THE FACE OF CURB.
EXISTING UTILITIES NOTE:CONTRACTOR SHALL FIELD VERIFY THE LOCATION OF ALL EXISTINGUTILITIES BEFORE WORK BEGINS. CONTRACTOR IS RESPONSIBLEFOR ANY DAMAGE THAT OCCURS TO EXISTING UTILITIES DURINGCONSTRUCTION.
WATERLINE NOTES:1.INSTALL THRUST BLOCKS AT ALL WATERLINE BENDS/TEES.2.CONTRACTOR SHALL MAINTAIN 4 FEET OF COVER OVERWATERLINES.FIRE HYDRANT NOTE: PRIVATE FIRE HYDRANTS SHALL BE PAINTED YELLOW AND PUBLICFIRE HYDRANTS SHALL BE PAINTED RED PER THE CITY OFSPARTANBURG FIRE AND BUILDING DEPARTMENT.GENERAL FIRE SPRINKLER SYSTEM NOTES:1.THE EXTERIOR FIRE PROTECTION SERVICE LINE SIZES AREAPPROXIMATE AND SHOWN FOR PERMIT PURPOSES ONLY. CONTRACTORSHALL REFER TO FIRE PROTECTION PLANS TO VERIFY FIRE PROTECTIONSERVICE LINE SIZES PRIOR TO COMMENCING CONSTRUCTION.2.A LICENSED FIRE SPRINKLER ENGINEER AND CONTRACTOR IS REQUIREDTO SUBMIT SHOP DRAWINGS AND HYDRAULIC CALCULATIONS OF THEBUILDING SPRINKLER SYSTEM TO THE APPROPRIATE REVIEWJURISDICTION.
WATER MAIN AND SEWER MAIN NOTE: THE CONTRACTOR SHALL MAINTAIN AT MINIMUM 10 FEETHORIZONTAL SEPARATION AND 18" VERTICAL SEPARATION BETWEENALL WATER AND SEWER MAINS PER SWS. REQUIREMENTS ANDSCDHEC REGULATION 61-67.
CLEANOUT NOTE:1.CONTRACTOR TO ENSURE THAT ALL CLEANOUTS SHALL BE FLUSHWITH FINISHED GRADE.2.CLEANOUTS SHALL BE INSTALLED AT EACH CHANGE OFDIRECTION GREATER THAN 45 DEGREES AND IN SPACINGINTERVALS OF 100' OR LESS.3.ALL CLEANOUTS ARE TO BE H20 LOAD RATED.
SCDOT NOTE:ANY WORK BUILT WITHIN THE SCDOT R/W THAT IS NOT BUILT PER THESCDOT APPROVED PERMIT AND PLANS IS SUBJECT TO REMOVAL ANDREPLACEMENT PER APPROVED PERMIT AND PLANS AFTERINSPECTION.ENCROACHMENT NOTE: CONTRACTOR IS RESPONSIBLE TO OBTAIN ALL CITYAND SCDOT ENCROACHMENT PERMITS.
FIRE SERVICE LINE TAP NOTE: CONTRACTOR WILL BE RESPONSIBLE FOR INSTALLING EACH 6" FIRE TAP ONTHE EXISTING 6" WATER MAIN. CONTRACTOR WILL ALSO BE RESPONSIBLE FORALL WORK REQUIRED FOR BRINGING THE 6" FIRE SERVICE LINE TO 1' ABOVETHE FINISH FLOOR. CONTRACTOR TO INSTALL THE BACK FLOW PREVENTERINSIDE THE RISER ROOM (DESIGN BY OTHERS). CONTRACTOR IS TOCOORDINATE FIRE SERVICE LINE INSTALLATION WITH SPARTANBURG WATER.CONTRACTOR TO CONFIRM FIRE LINE SIZE WITH SPRINKLER DESIGNER.CONTRACTOR TO COORDINATE WITH CIVIL ENGINEER AS REQUIRED.DOMESTIC SERVICE LINE TAP NOTE: SPARTANBURG WATER WILL BE RESPONSIBLE FOR INSTALLING EACH 2" DOMESTIC TAP ON EXISTING 6"WATER MAIN. SPARTANBURG WATER WILL ALSO BE RESPONSIBLE FOR ALL WORK REQUIRED FORBRINGING THE DOMESTIC WATER LINE TO THE WATER METER. SPARTANBURG WATER WILL ALSO INSTALL2" DOMESTIC WATER METER AND BOX. CONTRACTOR IS TO COORDINATE DOMESTIC SERVICE LINE ANDMETER INSTALLATION WITH SPARTANBURG WATER NEW CONNECTIONS (864-583-7361).
DOMESTIC SERVICE LINE BACK FLOW PREVENTER NOTE: CONTRACTOR IS RESPONSIBLE FOR THE INSTALLATION OF A SWS APPROVED (LEAD FREE) 2" DOUBLECHECK VALVE ASSEMBLY BACK FLOW PREVENTER AND BOX AFTER DOMESTIC METER. CONTRACTOR TOCOORDINATE WITH SPARTANBURG WATER NEW CONNECTIONS (864-583-7361).IRRIGATION NOTE:ANY ADDITIONAL IRRIGATION WITHIN SCDOT RIGHT-OF-WAY MUST BEDONE UNDER AN SCDOT PERMIT.
705710715720
735
720725730
735
720725730
735
735740
740
745
745
750
750
725725 730 735
720
725
725
725730735
740
745725730
720
725
730
715
735725730
715720725730735
725730735
725
730
723723 733S
S
S
D
D
D DD
DWSOWSOWSOHYDGSO
G
DD
G
S
#4 RBIN 3" PIPE
#4 RBIN 3" PIPE
2" BOLT
1-1/2" OT2" DISKIN 3" PIPE
3/4" OT
#4 RB
D
MONK STR/W UNKNOWN
OXFORD RD50' R/W PER PB 175 PG 56
W MAIN STSC HWY 2975' R/W PER PB 175 PG 56
SSMHRIM:724.512" VCP INV (A):703.815" VCP INV (B):700.915" VCP INV (C):701.1
SSMHRIM:721.912" VCP INV (A):711.312" VCP INV (B):711.2
SSMHRIM:727.2SEE NOTE 20SSMHRIM:724.0SEE NOTE 20
N/F: MARSHALL CLARK ET ALTMS: 7-12-13-048.00DB 127-M PG 659PB 2 PG 71-72
N/F: STEPHEN WASHINGTONTMS: 7-12-13-042.00DB 122-L PG 874
N/F: CAROLINA INS& INVESTMENT COTMS: 7-12-13-041.00DB 33-D PG 495
N/F: KAPASI INVESTMENTS, LLCTMS: 7-12-13-040.00DB 93-Q PG 778PB 165 PG 738N/F: JAMES & LYNN FLYNNTMS: 7-12-13-035.00DB 75-U PG 533PB 177 PG 568
N/F: NEW LIFE MINISTRIESCHURCH OF SPARTANBURGTMS: 7-12-13-038.00DB 70-T PG 575PB 29 PG 52
N/F: SPANN VENTURES LLCTMS: 7-12-13-037.00DB 124-A 569PB 10 PG 100
N/F: MARSHALL CLARK ET ALTMS: 7-12-13-047.00DB 127-M PG 659PB 2 PG 71-72
N/F: JBURKE INVESTMENTS LLCTMS: 7-12-13-020.00DB 124-Z PG 405PB 25-266
INTERMITTENTSTREAM 1 (CONT.)
PERENNIALSTREAM 1(CONT.) SSSMHRIM: 728.0IE(A): 719.7IE(B): 719.6
INTERMITTENTSTREAM 1105 LF
~ASPHALT~
~ASPHALT~
ABC
AB
D E
AB
724
735739725730
720721
722722
723 723
721
721
721
724
736737735730725724
725
723
724
734733732
724724
721
722723724
726727728729
724
723
721722723
722723724
721721723724723724
722722
722
722
724
725
725
725725725
725
724723724
724
723725
YI
50' CONSTRUCTIONBUFFER (TYP.)50' CONSTRUCTIONBUFFER (TYP.)
50' CONSTRUCTIONBUFFER (TYP.)50' CONSTRUCTIONBUFFER (TYP.)
CONSTRUCTION BUFFER
APPROXIMATE CENTERLINE OFJURISDICTIONAL STREAM AS INDICATED INEAS WETLAND DELINEATION REPORT,DATED APRIL 1, 2022.
APPROXIMATE CENTERLINE OFJURISDICTIONAL STREAM AS INDICATED INEAS WETLAND DELINEATION REPORT,DATED APRIL 1, 2022.
MH A2 (Ø5')DOGHOUSE MANHOLESTA:0+93.75RIM:726.25IE IN:719.10 (MH EX. SSMH#3)IE OUT:719.00 (MH A1)
72LF-10" PVC @ 5.57%S64° 14' 47.87"W
MH A1 (Ø5')DOGHOUSE MANHOLESTA:0+27.30RIM:725.00IE IN:715.00 (MH A2)IE OUT:699.05 (MH EX. SSMH#4)
0+00
1+00
2+00
3+004+00
5+005+03.58
87.8°89°0+001+001+46.14
25'
4" PVC SANITARYSEWER SERVICELATERAL (TYP.)
2 - 1,500 GALLON GREASETRAP TO COMPLY WITHSSSD REQUIREMENTS70 LF -4" PVCSANITARY SEWERSERVICE LINE @ MIN.2%40LF -6" PVCSANITARY SEWERSERVICE LINE @ MIN. 1%
SEE MEP PLANS FOR CONTINUATIONOF UTILITY SERVICES INTO BUILDING(TYP.)145 LF -6" PVCSANITARY SEWERSERVICE LINE @ MIN. 1%APPROXIMATE LOCATION OFEXISTING SSSD COLLAPSEDSEWER MAIN TO BE REMOVED
EXISTING 12" VCPPUBLIC SEWER MAIN
CONTRACTOR TO VERIFY INVERT INFIELD PRIOR TO CONSTRUCTIONAND REPORT ANY DISCREPANCIESCONTRACTOR TO INSTALLDOGHOUSE MANHOLE ON EXISTINGSANITARY SEWER MAINCONTRACTOR TO COORDINATESEQUENCE OF CONSTRUCTION OFSANITARY SEWER MAIN WITHSPARTANBURG WATER. CONTRACTOR ISRESPONSIBLE FOR MAINTAINING FLOWFROM UPSTREAM SEWER SYSTEM.
CONTRACTOR TO VERIFY INVERT INFIELD PRIOR TO CONSTRUCTIONAND REPORT ANY DISCREPANCIESCONTRACTOR TO INSTALLDOGHOUSE MANHOLE ON EXISTINGSANITARY SEWER MAIN
25' SPARTANBURG SANITARY SEWERDISTRICT EASEMENT
CONTRACTOR TO COORDINATESEQUENCE OF CONSTRUCTION OFSANITARY SEWER MAIN WITHSPARTANBURG WATER. CONTRACTOR ISRESPONSIBLE FOR MAINTAINING FLOWFROM UPSTREAM SEWER SYSTEM.
CONTRACTOR TO VERIFY INVERT INFIELD PRIOR TO CONSTRUCTIONAND REPORT ANY DISCREPANCIES25' SPARTANBURG SANITARYSEWER DISTRICT EASEMENT
25' SPARTANBURG SANITARYSEWER DISTRICT EASEMENT128LF-8" PVC @ 1.02%N46° 54' 19.28"E
51LF-8" DIP @ 4.02%N15° 25' 59.45"W
MH B1 (Ø4')STA:2+85.80RIM:720.95IE IN:712.60 (MH B2)IE IN:712.60 (MH CO )IE OUT:712.50 (MH 22)
MH B2 (Ø4')STA:4+13.59RIM:724.00IE IN:714.00 (MH 16)IE OUT:713.90 (MH B1)
25'
25' SPARTANBURG SANITARYSEWER DISTRICT EASEMENT25'
MH EX. SSMH#2IE OUT:719.60 (MH 16)
MH EX. SSMH#1IE IN:701.00 (MH 24)
CONTRACTOR TO VERIFYINVERT IN FIELD PRIOR TOCONSTRUCTION AND REPORTANY DISCREPANCIES
CONTRACTOR TO VERIFY INVERT INFIELD PRIOR TO CONSTRUCTIONAND REPORT ANY DISCREPANCIES
EXISTING 15" VCPPUBLIC SEWER MAIN
98.6°117.7°25'
25'
CONNECT TO SANITARYSEWER MANHOLE
OUTSIDE DROP CONNECTIONFROM MH A2 TO MANHOLE A1TOP OF DROP IE IN:715.00BOTTOM OF DROP IE OUT:699.15
1 - 1,500 GALLON GREASETRAP TO COMPLY WITHSSSD REQUIREMENTSLOCKING SANITARYSEWER MANHOLE TOCOMPLY WITH SSSDREQUIREMENTS
8'25' 37LF-8" PVC @ 6.47%S51° 40' 28.56"E51LF-8" DIP @ 6.47%S51° 40' 28.56"E
CONFIRM INVERT ELEVATIONS OUTOF BUILDING WITH MEP PLANS (TYP.)
OUTSIDE DROP CONNECTIONFROM GREASE TRAPSSANITARY SEWERSERVICES TO CROSSUNDER STORM DRAIN
30LF -4" PVCSANITARY SEWERSERVICE LINE @ MIN.2%
38 LF -4" PVCSANITARY SEWERSERVICE LINE@ MIN. 2%LOCKING SANITARYSEWER MANHOLE TOCOMPLY WITH SSSDREQUIREMENTS
1 - 1,500 GALLON GREASETRAP TO COMPLY WITHSSSD REQUIREMENTSLOCKING SANITARYSEWER MANHOLE TOCOMPLY WITH SSSDREQUIREMENTS58LF-6" PVC @ 7.82%COIE OUT:716.00 (MH 21)UTILITY CROSSING6" SEWER SERVICE TO CROSSBELOW 18" RCP STORM DRAIN18" RCP IE:± 715.156" SEWER IE:± 713.50
COIE OUT:± 720.00195 LF -4" PVCSANITARY SEWERSERVICE LINE @ MIN.2%
FOUNTAIN DESIGNER SHALL COORDINATEWITH SPARTANBURG SANITARY SEWERDISTRICT FOR FOUNTAIN BACKWASHDISCHARGE REQUIREMENTS INCLUDINGDECHLORINATION REQUIREMENTS
COIE OUT:716.00 (MH 22)
COIE OUT:± 716.00
COIE OUT:714.00 (MH B1)24LF-6" PVC @ 5.78%UTILITY CROSSING6" SEWER SERVICE TO CROSSBELOW 18" RCP STORM DRAIN18" RCP IE:± 715.306" SEWER IE:± 713.7550 LF -4" PVCSANITARY SEWERSERVICE LINE@ MIN. 2%
17'25'
WYE CONNECTIONCONNECT 6" SERVICETO SEWER MAIN45LF-6" PVC @ 9.30%
211LF-8" PVC @ 4.02%N15° 25' 59.45"W
EXISTING BUILDING(PROPOSED RESTAURANT)EXISTING BUILDING(PROPOSED GYM)EXISTING FACILITY(PROPOSED MIXED-USE)
CONSTRUCTION BUFFER
C8.1UTILITY PLAN- SEWER 02/16/23BC02/21/23D03/27/23 F04/12/23G04/27/2305/17/23IJ06/02/23
COPYRIGHT c SEAMON, WHITESIDE & ASSOCIATES, INC.THIS DRAWING SHALL NOT BE REPRODUCED IN ANY MANNER OR USED FOR ANY PURPOSE WITHOUT WRITTEN PERMISSION.
GR4714DBLM/CS10/14/22DATE:
501 WANDO PARK BOULEVARD, SUITE 200 | MOUNT PLEASANT, SC 29464 | 508 RHETT STREET, SUITE 101 | GREENVILLE, SC 29601
500 W MAIN STCITY OF SPARTANBURG, SOUTH CAROLINACOKE FACILITYREDEVELOPMENT PHASE 1REVISION HISTORYDRAWN BY:CHECKED BY:SW+ PROJECT:
MOUNT PLEASANT, SC843.884.1667GREENVILLE, SC864.298.0534
WWW.SEAMONWHITESIDE.COMSUMMERVILLE, SC843.972.0710SPARTANBURG, SC864.272.1272CHARLOTTE, NC980.312.54506/1/23
153060SCALE: 1" = 30'0
SEWNR
Know what'sbelow.before you dig.CallFOR NOTES AND LEGEND,SEE SHEET C1.1
UTILITY LEGEND
EXISTING WATER LINEPROPOSED WATER LINE
EXISTING FIRE HYDRANTPROPOSED FIRE HYDRANTPROPOSED WATER VALVEPROPOSED IRRIGATION METER/BFPPROPOSED BFP
EXISTING SEWER LINEPROPOSED SEWER MAIN
EXISTING SEWER MANHOLEPROPOSED SEWER MANHOLEPROPOSED FIRE PROTECTION LINEPROPOSED WATER SERVICE LINE
PROPOSED SEWER SERVICE LINE
EXISTING UTILITIES NOTE:CONTRACTOR SHALL FIELD VERIFY THE LOCATION OF ALL EXISTINGUTILITIES BEFORE WORK BEGINS. CONTRACTOR IS RESPONSIBLEFOR ANY DAMAGE THAT OCCURS TO EXISTING UTILITIES ANDSTRUCTURES DURING CONSTRUCTION.
SANITARY SEWER MAIN PROFILE NOTE: REFERENCE SANITARY SEWER MAIN PROFILES (SHEET C8.2) FORPROFILE INFORMATION.
SANITARY SEWER MAIN AS-BUILT SURVEY: CONTRACTOR IS RESPONSIBLE FOR PROVIDING AN AS-BUILTSURVEY OF THE ENTIRE SANITARY SEWER SYSTEM TO THEENGINEER AS PART OF THE CONDITIONS OF THE SCDHECCONSTRUCTION PERMIT.
SPARTANBURG WATER PRE-CONSTRUCTION CONFERENCE:A PRE-CONSTRUCTION CONFERENCE WITH SPARTANBURG WATER ISREQUIRED AT LEAST 72 HOURS IN ADVANCE OF THE START OFWATER AND SEWER WORK. CONTRACTOR IS TO COORDINATE WITHENGINEER (SEAMONWHITESIDE AT 864-298-0534) TO SET UP THEMEETING WITH SPARTANBURG WATER (AT SPARTANBURG WATEROFFICE AT 175 NORTH LIBERTY STREET). THE FOLLOWINGPERSONNEL ARE REQUIRED TO ATTEND THE CONFERENCE:1.SWS-SSSD PROJECT MANAGER/ STAFF ENGINEER2.SWS-SSSD INSPECTOR3.DESIGN ENGINEER (SEAMONWHITESIDE)4.CONTRACTOR AND ANY SUB-CONTRACTORSSPARTANBURG WATER TAP AND CAPACITY FEES NOTE: OWNER IS RESPONSIBLE FOR ALL TAP AND CAPACITY FEESREQUIRED BY SPARTANBURG WATER FOR THE INSTALLATION OF ALLWATER AND SEWER LINES. CONTRACTOR IS TO COORDINATE WITHOWNER AND SPARTANBURG WATER BEFORE STARTING WORK.
SPARTANBURG WATER SPECIFICATIONS NOTE:CONTRACTOR IS RESPONSIBLE FOR ENSURING ALL WATER ANDSEWER INSTALLATION WORK ADHERES TO SPARTANBURG WATERSTANDARD SPECIFICATIONS.
WATER AND SANITARY SEWER TESTING: 1.CONTRACTOR IS RESPONSIBLE FOR COORDINATING ANDPERFORMING ALL WATER AND SANITARY SEWER TESTINGTHAT IS REQUIRED BY SPARTANBURG WATER AND SCDHECBEFORE LINES ARE PUT INTO OPERATION.2.ALL INSTALLED MAINS MUST MEET SCDHEC TESTINGGUIDELINES AS PART OF THE CONDITIONS OF THE SCDHECCONSTRUCTION PERMIT BEFORE A PERMIT TO OPERATE WILLBE ISSUED BY SCDHEC.
SEWER MAIN PIPE MATERIAL REQUIREMENTS:ALL SANITARY SEWER PIPING TO BE SDR 35 PVC UNLESS PIPES AREOVER 16' IN DEPTH MUST BE SDR-26 AND PIPES OF 20' IN DEPTH MUSTBE DIP.
WATER FOUNTAIN: 1.CONTRACTOR SHALL COORDINATE ALL FOUNDATION FILTERDRAINAGE REQUIREMENTS WITH FOUNTAIN DESIGNER(DESIGNED BY OTHERS).2.FOUNTAIN DESIGNER SHALL COORDINATE WITH SPARTANBURGWATER FOR ALL BACKWASH DISCHARGE REQUIREMENTS.STORM DRAIN CROSSING:ANY SANITARY SEWER MAIN CROSSING WITH STORM DRAIN WITHLESS THAN 18" OF CLEARANCE SHALL BE DUCTILE IRON PIPE (DIP).PER SPARTANBURG WATER REQUIREMENTS.
SANITARY SEWER MAIN OWNERSHIP:ALL SANITARY SEWER MAIN LINES AND MANHOLES THAT ARE PARTOF THE A AND B LINE ARE PUBLIC. SEWER MAINS TO BE OWNED ANDMAINTAINED BY SPARTANBURG SANITARY SEWER DISTRICT (SSSD).WATER MAIN AND SEWER MAIN NOTE: THE CONTRACTOR SHALL MAINTAIN AT MINIMUM 10 FEETHORIZONTAL SEPARATION AND 18" VERTICAL SEPARATION BETWEENALL WATER AND SEWER MAINS PER SWS. REQUIREMENTS ANDSCDHEC REGULATION 61-67.
CLEANOUT NOTE:1.CONTRACTOR TO ENSURE THAT ALL CLEANOUTS SHALL BE FLUSHWITH FINISHED GRADE.2.CLEANOUTS SHALL BE INSTALLED AT EACH CHANGE OFDIRECTION GREATER THAN 45 DEGREES AND IN SPACINGINTERVALS OF 100' OR LESS.3.ALL CLEANOUTS ARE TO BE H20 LOAD RATED.
SCDOT NOTE:ANY WORK BUILT WITHIN THE SCDOT R/W THAT IS NOT BUILT PER THESCDOT APPROVED PERMIT AND PLANS IS SUBJECT TO REMOVAL ANDREPLACEMENT PER APPROVED PERMIT AND PLANS AFTERINSPECTION.ENCROACHMENT NOTE: CONTRACTOR IS RESPONSIBLE TO OBTAIN ALL CITYAND SCDOT ENCROACHMENT PERMITS.
SANITARY SEWER A LINE PROFILE698700705710715720725
698700705710715720725
0+00EG:723.85'FG:723.85'EG:725.94'FG:725.94'1+00EG:726.99'FG:726.99'1+46.14EG:727.20'FG:727.20'STA:0+93.75RIM:726.25IE IN:719.10 (MH EX. SSMH#3)IE OUT:719.00 (MH A1)MH A2 (∅5')DOGHOUSE MANHOLE
72LF-10" PVC@ 5.57%
STA:0+27.30RIM:725.00IE IN:715.00 (MH A2)IE OUT:699.05 (MH EX. SSMH#4)MH A1 (∅5')DOGHOUSE MANHOLE
PUBLIC SANITARY SEWER MAIN
EXISTING 12" VCP SEWER MAIN FROM EXISTINGSEWER MANHOLE IN W. MAIN STREET
EXISTING 15" VCP SEWER MAIN TOSEWER MANHOLE IN W. MAIN STREET.
OUTSIDE DROP CONNECTIONFROM MH A2 TO MANHOLE A1TOP OF DROP IE IN:715.00BOTTOM OF DROP IE OUT:699.15
SANITARY SEWER B LINE PROFILE700705710715720725730735
700705710715720725730735
-0+50EG:'FG:'0+00EG:724.52'FG:723.69'EG:723.11'FG:722.00'1+00EG:721.55'FG:721.05'EG:720.55'FG:721.00'2+00EG:720.28'FG:721.01'EG:720.98'FG:721.00'3+00EG:721.91'FG:721.02'EG:722.64'FG:722.10'4+00EG:'FG:723.28'EG:722.40'FG:723.51'5+00EG:728.47'FG:'EG:'FG:'5+51.64EG:'FG:'
128LF-8" PVC@ 1.02%
50LF-8" DIP@ 4.02%
RIM:724.00IE IN:714.00 (MH 16)IE OUT:713.90 (MH B1)MH B2 (∅4')RIM:720.95IE IN:712.60 (MH B2)IE IN:712.60 (MH CO )IE OUT:712.50 (MH 22)MH B1 (∅4')
PUBLIC SANITARY SEWER MAIN
STA:0+00.00RIM:723.69IE IN:701.00 (MH 24)MH EX. SSMH#1 (∅4')
36LF-8" PVC@ 6.47%
SANITARY SEWER MAINPIPE SHALL BE DUCTILEIRON PIPE WHENCOVER IS LESS THAN 3FEET FROM GRADE TOTOP OF PIPE (TYP.)STA:5+00.09RIM:728.46IE OUT:719.60 (MH 16)MH EX. SSMH#2 (∅4')
STORM_Ph1 PIPE24" RCPEXISTING 30" RCPSTORM DRAINIE:±712.0550LF-8" DIP@ 6.47%
211LF-8" PVC@ 4.02%PER SSSD REQUIREMENTSPIPES OVER 16' IN DEPTH MUSTBE SDR-26 AND PIPES OVER 20'IN DEPTH MUST BE DIP
PVC TO DIP TRANSITIONSSHALL BE GASKETED PVCBELL-BELL OR BELL-SPIGOTHARCO COUPLINGS(SEE SSSD SPECS)
720725730720725730
735
735740
740
745
745
750
750
725 730 735
720
725
725
725730735
720
725
715
735725730
723 733S S
SD
DD
DWSOWSOWSOHYDGSO
G
G
W MAIN STSC HWY 2975' R/W PER PB 175 PG 56
N/F: KAPASI INVESTMENTS, LLCTMS: 7-12-13-040.00DB 93-Q PG 778PB 165 PG 738
N/F: MARSHALL CLARK ET ALTMS: 7-12-13-047.00DB 127-M PG 659PB 2 PG 71-72
S
INTERMITTENTSTREAM 1105 LF
735725730723 723
721
721
721
724
736737735730725724
725
723
724
734733732
724724
721
722723724
726727728729723
721722723
722723724
721721723724723724
722722
722
724
725725
725
723724
724
YIMH A2 (Ø5')DOGHOUSE MANHOLESTA:0+93.75RIM:726.25IE IN:719.10 (MH EX. SSMH#3)IE OUT:719.00 (MH A1)
72LF-10" PVC @ 5.57%S64° 14' 47.87"W
MH A1 (Ø5')DOGHOUSE MANHOLESTA:0+27.30RIM:725.00IE IN:715.00 (MH A2)IE OUT:699.05 (MH EX. SSMH#4)
EXISTINGWAREHOUSEBUILDINGEXISTINGWAREHOUSEBUILDING
EXISTING COKEBUILDING
IE:701.0
0+00
1+00
2+00
3+004+00
5+005+03.58
87.8°89°0+001+001+46.14
25'CONTRACTOR TO INSTALLDOGHOUSE MANHOLE ON EXISTINGSANITARY SEWER MAIN
25' SPARTANBURG SANITARY SEWERDISTRICT EASEMENT
CONTRACTOR TO COORDINATESEQUENCE OF CONSTRUCTION OFSANITARY SEWER MAIN WITHSPARTANBURG WATER. CONTRACTOR ISRESPONSIBLE FOR MAINTAINING FLOWFROM UPSTREAM SEWER SYSTEM.
25' SPARTANBURG SANITARYSEWER DISTRICT EASEMENT
25' SPARTANBURG SANITARYSEWER DISTRICT EASEMENT128LF-8" PVC @ 1.02%N46° 54' 19.28"E
51LF-8" DIP @ 4.02%N15° 25' 59.45"W
MH B1 (Ø4')STA:2+85.80RIM:720.95IE IN:712.60 (MH B2)IE IN:712.60 (MH CO )IE OUT:712.50 (MH 22)
MH B2 (Ø4')STA:4+13.59RIM:724.00IE IN:714.00 (MH 16)IE OUT:713.90 (MH B1)
25'
MH EX. SSMH#2IE OUT:719.60 (MH 16)
MH EX. SSMH#1IE IN:701.00 (MH 24)EXISTING 15" VCPPUBLIC SEWER MAIN
98.6°117.7°25'
25'
OUTSIDE DROP CONNECTIONFROM MH A2 TO MANHOLE A1TOP OF DROP IE IN:715.00BOTTOM OF DROP IE OUT:699.15
8'25' 37LF-8" PVC @ 6.47%S51° 40' 28.56"E51LF-8" DIP @ 6.47%S51° 40' 28.56"E
COIE OUT:716.00 (MH 21)
COIE OUT:± 720.00
COIE OUT:716.00 (MH 22)
CO
COIE OUT:714.00 (MH B1)
17'25'
WYE CONNECTIONCONNECT 6" SERVICETO SEWER MAIN
211LF-8" PVC @ 4.02%N15° 25' 59.45"W
C8.2SANITARYSEWERPROFILES 02/16/23BC02/21/23D03/27/23 F04/12/23G04/27/2305/17/23IJ06/02/23
COPYRIGHT c SEAMON, WHITESIDE & ASSOCIATES, INC.THIS DRAWING SHALL NOT BE REPRODUCED IN ANY MANNER OR USED FOR ANY PURPOSE WITHOUT WRITTEN PERMISSION.
GR4714DBLM/CS10/14/22DATE:
501 WANDO PARK BOULEVARD, SUITE 200 | MOUNT PLEASANT, SC 29464 | 508 RHETT STREET, SUITE 101 | GREENVILLE, SC 29601
500 W MAIN STCITY OF SPARTANBURG, SOUTH CAROLINACOKE FACILITYREDEVELOPMENT PHASE 1REVISION HISTORYDRAWN BY:CHECKED BY:SW+ PROJECT:
MOUNT PLEASANT, SC843.884.1667GREENVILLE, SC864.298.0534
WWW.SEAMONWHITESIDE.COMSUMMERVILLE, SC843.972.0710SPARTANBURG, SC864.272.1272CHARLOTTE, NC980.312.54506/1/23
SCALE: 1" = 50'25501001.0'2.5'5.0'0.0'SCALE: 1" = 5.0'0
R
Know what'sbelow.before you dig.Call
153060SCALE: 1" = 30'0SANITARY SEWER PROFILE PLAN VIEW:SEWN
STORM DRAIN CROSSING:ANY SANITARY SEWER MAIN CROSSING WITH STORM DRAINWITH LESS THAN 18" OF CLEARANCE SHALL BE DUCTILE IRONPIPE (DIP) FOR A MINIMUM OF ONE DUCTILE IRON PIPE SECTIONOR AS REQUIRED BY SPARTANBURG PER SPARTANBURGWATER REQUIREMENTS.
SANITARY SEWER SERVICE CONNECTIONS:SEE SHEETS C8.1 UTILITY PLAN - SANITARY SEWER FOR ALLSEWER SERVICE CONNECTION INFORMATION.NOTE:SEE SHEET C8.1 FOR ALL SANITARY SEWER UTILITY NOTES.
SSSD REQUIREMENTS:1.PER SSSD REQUIREMENTS PIPES OVER 16' IN DEPTH MUST BESDR-26 AND PIPES OF 20' IN DEPTH MUST BE DIP.2.PVC TO DIP TRANSITIONS SHALL BE GASKETED PVC BELL-BELL ORBELL-SPIGOT HARCO COUPLINGS. (SEE SSSD SPECS).
C9.0SITE DETAILS(1 OF 3) 02/16/23B D03/27/23 F04/12/23 05/17/23IJ06/02/23
COPYRIGHT c SEAMON, WHITESIDE & ASSOCIATES, INC.THIS DRAWING SHALL NOT BE REPRODUCED IN ANY MANNER OR USED FOR ANY PURPOSE WITHOUT WRITTEN PERMISSION.
GR4714DBLM/CS10/14/22DATE:
501 WANDO PARK BOULEVARD, SUITE 200 | MOUNT PLEASANT, SC 29464 | 508 RHETT STREET, SUITE 101 | GREENVILLE, SC 29601
500 W MAIN STCITY OF SPARTANBURG, SOUTH CAROLINACOKE FACILITYREDEVELOPMENT PHASE 1REVISION HISTORYDRAWN BY:CHECKED BY:SW+ PROJECT:
MOUNT PLEASANT, SC843.884.1667GREENVILLE, SC864.298.0534
WWW.SEAMONWHITESIDE.COMSUMMERVILLE, SC843.972.0710SPARTANBURG, SC864.272.1272CHARLOTTE, NC980.312.54506/1/23
ADA Curb Ramp - Type CSCALE: NOT TO SCALE8Detectable Warning Truncated DomesSCALE: NOT TO SCALE9CONCRETE SIDEWALK (ON-SITE ONLY)SCALE: NOT TO SCALE10
ADA CURB RAMP - TYPE ASCALE: NOT TO SCALE6 ADA SignSCALE: NOT TO SCALE3Precast Concrete Wheel StopsSCALE: NOT TO SCALE4Stop Bar Pavement Marking & Stop SignSCALE: NOT TO SCALE5
ADA Parking Space StripingSCALE: NOT TO SCALE2 Standard Parking Space StripingSCALE: NOT TO SCALE1
ADA CURB RAMP - TYPE BSCALE: NOT TO SCALE7
NOTES:1.DO NOT CONTINUE STRIPING INTO GUTTER2.ALL STRIPING TO BE TRAFFIC-RATED PAINT3.USE 2' X 1' T MARKS BETWEEN PARALLEL PARKING SPACES, USE 1' X 1' L MARKS AT END OF PARALLEL PARKING ROWS
WHITE PAVEMENTSTRIPING (TYP)
FACE OF CURB(AS INDICATED ON PLANS)
4"(TYP)
18' MINIMUM OR ASINDICATED ON PLANS90°
9' MIN
EDGE OF PAVEMENT
NOTES:1.ALL ADA PARKING SPACES TO BE TRAFFIC RATED CONCRETE - SEE GEOTECH PAVEMENT SECTIONS2.ALL PAVEMENT STRIPING TO BE TRAFFIC PAINT3.THE LONGITUDINAL SLOPE OF ALL SURFACES ALONG THE ADA ACCESSIBLE ROUTE, WHICH ARE NOT SPECIFICALLY NOTED AS BEING A RAMP SHALL NOT EXCEED 1:20.4.RAMPS SHALL NOT EXCEED A SLOPE OF 1:12.5.NO TRANSVERSE SLOPE SHALL EXCEED 1:50.6.CONTRACTOR SHALL FIELD VERIFY SLOPES BEFORE INSTALLATION AND NOTIFY ENGINEER IMMEDIATELY IF MAXIMUM SLOPES ARE EXCEEDED
9' MIN
9' ACCESSAISLE4"(TYP)9' MINVAN SPACE
ADA PARKING SIGN(SEE DETAIL)EDGE OF PAVEMENTPRECAST CONCRETEWHEEL STOP (SEE DETAIL)FACE OF CURB(AS INDICATED ON PLANS)
48" MIN INTERNATIONALSYMBOL OF ACCESSIBILITY(TYP)BLUE PAVEMENT STRIPING(TYP)
ADA CURB RAMP(AS INDICATED ON PLANS)18' MINIMUM OR ASINDICATED ON PLANS
LOCATION ASINDICATED ON PLANS90°'
3'O.C.
45°
18' MINIMUM OR ASINDICATED ON PLANS
4"(TYP)
EDGE OF PAVEMENTFACE OF CURB(AS INDICATED ON PLANS)WHITE PAVEMENTSTRIPING (TYP)9' MIN
45°'
18' MINIMUM OR ASINDICATED ON PLANS9'ACCESSAISLEPRECAST CONCRETEWHEEL STOP (SEE DETAIL)EDGE OF PAVEMENTFACE OF CURB(AS INDICATED ON PLANS)ADA PARKING SIGN(SEE DETAIL)9' MINVAN SPACE4"(TYP)
9' MIN
3'O.C.
ADA CURB RAMP(AS INDICATED ON PLANS)
48" MIN INTERNATIONALSYMBOL OF ACCESSIBILITY(TYP)
BLUE PAVEMENT STRIPING(TYP)
90 DEGREE PARKING SPACES45 DEGREE PARKING SPACESPARALLEL PARKING SPACES22' MIN WIDTH9' MIN STALLDEPTH
1'2' 1'1:1 CHAMFERADDITIONAL PARKINGSTALLS AND CHAMFERS
STREET / DRIVESEE NOTE #3
18"
INCLUDE "VAN ACCESSIBLE"SIGN FOR ALL SPACES INDICATED ONPLANS2" LETTERING (GREEN)BORDER STRIP (GREEN)BLUE BACKGROUNDWHITE BACKGROUNDWHITE SYMBOL
FINISHEDGRADE6"36"
ACCESSIBLE12"VANMAX.96"6"6"RESERVEDPARKING18"
NOTES:1. SIGN SHALL BE 0.080" THICK ALUMINUM WITH APPLIED REFLECTIVE SHEETING INACCORDANCE WITH SCDOT STANDARD SPECIFICATIONS.2. POST SHALL BE 3" SQUARE OR 3" DIA. STEEL TUBE WITH WELDED CAP (PAINTED BLACK).3. CONTRACTOR TO WALL MOUNT SIGN WHERE SPECIFIED.
CAST-IN-PLACE CONCRETE
7' MIN
CURB & GUTTER(AS APPLICABLE)FACE OF CURB OREDGE OF ASPHALT(AS APPLICABLE)
PAINTED PARKINGSPACE LINETYPICAL LOCATION
72"HOLE FORDOWEL ANCHOR12" MIN. DIAMETER
PRECAST CONCRETE WHEEL STOP,LONGITUDINALLYREINFORCED WITH TWO #3 REBAREQUALLY SPACED.
NOTES:1. ANCHOR WITH 24"LONG GALVANIZEDSTEEL DOWELS DRIVENINTO ANCHOR HOLES.DOWEL DIAMETERSHALL BE 18" SMALLERTHAN ANCHOR HOLE.6'9'1.5'1.5'3.0' MIN
5"2-1/2"9"
4' MIN.SEE PLANS FOR LENGTHNOTES:1.ALL MARKINGS SHALL BE TRAFFIC PAINT.2.ALL MARKINGS SHALL BE INSTALLED IN ACCORDANCE WITH S.C.D.O.T. STANDARDSPECIFICATIONS AND SOUTH CAROLINA MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES.
CURB OR EDGE OF PAVEMENT(AS APPLICABLE)EDGE OF TRAVEL LANE24" STOP BAR
NOTE:STOP SIGN AND INSTALLATION TO CONFORMWITH S.C.M.U.T.D. SPECIFICATIONS.USE SCDOT BREAKAWAY DETAIL#651-110-00 FOR THE SIGN POST.BACKGROUND: RED - REFLECTORIZEDLEGEN AND BORDER: WHITE - REFLECTORIZEDUSE TYPE RE-1-30 30"x30" SIGN MOUNTED ON 3"SQUARE OR 3" DIA. STEEL TUBE WITH WELDEDCAP (PAINTED BLACK).6' EDGE OF PAVEMENT(ROADWAY CONDITION)2' FACE OF CURB(URBAN CONDITION)
5' MINIMUMOR
STOP SIGN
STOP BAR PAVEMENTMARKINGAS REQ.(72" MIN. FOR 6" RISE)PLANAS REQ.(72" MIN. FOR 6" RISE)A
B BASLOPEAPRONUNIFORMLY(12:1 MAX)
CAST-IN-PLACECONCRETESIDEWALK
TRUNCATEDDOMEDETECTABLEWARNING PAVER(SEE NOTE #3)SEENOTE #2
AS REQ.(72" MIN. FOR 6" RISE)SECTION A-A48" MINTOP OFVEHICULARSURFACECOLD JOINT (TYP)
24"
SECTION B-BCOLD JOINT (TYP)4" THICK CONCRETE12" THICK MORTARSETTING BED12:1 MAX.3' MIN.WIDTHBEHINDRAMP
RAMPDOWNRAMPDOWNRAMPDOWNVEHICULARSURFACEFLUSH WITHGUTTERCONC. GUTTERTOP OFCURB TOBE FLUSHWITH WALK
NOTES:1. CONCRETE PORTION OF RAMP SHALL HAVE A LIGHT BROOM FINISH PERPENDICULAR TO SLOPE.2. PAVER JOINT PATTERN WILL VARY BASED ON PAVER SIZE AND CONFIGURATION.3. TRUNCATED DOMES TO BE A CHARCOAL COLOR, UNLESS OTHERWISE INDICATED.
(SEE SITE PLAN)
AS REQ.(72" FOR 6" RISE)SECTION A-A
(48"MIN)
MAX CROSSSLOPE=2%
PLAN
B B
A
A
AS REQ.(72" FOR 6" RISE)RAMPDOWNSLOPEAPRONUNIFORMLY(12:1 MAX)
TRUNCATEDDOMEDETECTABLEWARNING PAVER(SEE NOTE #3)CAST-IN-PLACECONCRETESIDEWALK
TOP OFCURB TOBE FLUSHWITH WALKTOP OFVEHICULARSURFACECOLD JOINT (TYP.)
SEENOTE #224"SECTION B-BCOLD JOINT (TYP.)4" THICK CONCRETE12" THICK MORTARSETTING BEDVEHICULARSURFACEFLUSH WITHGUTTERMAX CROSSSLOPE=2%CONC. GUTTER
SEE PLAN
TOP OFCURB TO BEFLUSH WITHWALKWAY
SEE PLAN(48" MIN.)
MAX 1:50CROSSSLOPE
CAST-IN-PLACE
RAMPDOWNNOTES:1. CONCRETE PORTION OF RAMP SHALL HAVE A LIGHTBROOM FINISH PERPENDICULAR TO SLOPE.2. PAVER JOINT PATTERN WILL VARY BASED ON PAVERSIZE AND CONFIGURATION.3. TRUNCATED DOMES TO BE A CHARCOAL COLOR,UNLESS OTHERWISE INDICATED.
CAST-IN-PLACECONCRETESIDEWALK
MAX1:50CROSSSLOPESECTION A-A
SEE PLANPLAN
B B
A
ATRUNCATEDDOMEDETECTABLEWARNING PAVER(SEE NOTE #3)
FACEOF CURBTOP OFVEHICULARSURFACECOLD JOINTSEENOTE #2LANDSCAPING
72" MIN.
24"
SECTION B-BCOLD JOINT (TYP.)4" THICK CONCRETE12" THICK MORTARSETTING BEDVEHICULARSURFACEFLUSH WITHGUTTER
FINISHEDGROUND
MAX. SLOPE12:1
RAMPDOWN
CONC.GUTTER
CONCRETECURB
FOR 6" RISE
TOP OF CURB
SEE PLAN(48" MIN.)
NOTES:1. CONCRETE PORTION OF RAMP SHALL HAVE A LIGHTBROOM FINISH PERPENDICULAR TO SLOPE.2. PAVER JOINT PATTERN WILL VARY BASED ON PAVERSIZE AND CONFIGURATION.3. TRUNCATED DOMES TO BE A CHARCOAL COLOR,UNLESS OTHERWISE INDICATED.
DOME ALIGNMENT
TRANSITION RAMP WITH DETECTABLE WARNINGS
PLAN VIEWDOME SPACING
TRUNCATED DOMESECTION0.90" - 1.40"0.180" - 0.249"INDIVIDUALLY**50 - 65% OF ACTUALBASE DIAMETER
1.6" - 2.4"1.6" - 2.4"MIN0.65"
AVERAGE0.190" - 0.249"(SEE NOTE 4)DIRECTION OFPED. TRAVELDIRECTION OFPED. TRAVEL24"6" TYPSIDEWALKSIDEWALK
NOTES:1.DETECTABLE WARNING SURFACES SHALL BE PROVIDED AT THE FOLLOWING LOCATIONS:(A) WHERE A SIDEWALK CROSSES A VEHICULAR WAY, EXCLUDING UN-SIGNALIZED DRIVEWAY CROSSINGS.(B) AT ISLANDS AND MEDIANS THAT ARE CUT THROUGH LEVEL WITH THE ROADWAY.2.AT CURB RAMPS AND BLENDED TRANSITIONS, DETECTABLE WARNING SURFACES SHALL BE LOCATED SO THE EDGE NEAREST THECURB LINE IS 6" MINIMUM AND 8" MAXIMUM DISTANCE FROM THE CURB LINE. THE SURFACE SHALL EXTEND A MINIMUM OF 24" ONTOTHE RAMP IN THE DIRECTION OF TRAVEL FOR THE FULL WIDTH OF THE CURB RAMP.3.DETECTABLE WARNING SURFACES SHALL CONSIST OF AN AREA OF TRUNCATED DOMES ALIGNED IN A SQUARE GRID PATTERN. THEBASE OF THESE DOMES SHALL BE 0.90"-1.40". THE TOP DIAMETER OF DOMES SHALL BE 50%-65% OF ACTUAL BASE DIAMETER, WITH AMINIMUM INDIVIDUAL HEIGHT OF 0.180" AND A MAXIMUM HEIGHT OF 0.249". THE AVERAGE OF TEN (10) INDIVIDUAL NODES PICKED ATRANDOM IN ANY SQUARE FOOT AREA SHALL BE 0.190"-0.249". THE DETECTABLE WARNING DOMES SHALL HAVE A CENTER-TO-CENTERSPACING OF 1.6-2.4".4.WHEN DOMES IN ANY ONE FOOT SQUARE AREA WEAR TO AN AVERAGE HEIGHT BELOW 0.151", THE SURFACE IS TO BE REPLACED.EXPANSION JOINT(SEE NOTE #4)
NOTES:1.SIDEWALK CROSS SLOPE NOT TO EXCEED 2%.2.SIDEWALK TO HAVE LIGHT BROOM FINISH,PERPENDICULAR TO DIRECTION OF TRAVEL.3.SEE PLAN FOR SIDEWALK WIDTH.4.UNLESS OTHERWISE SHOWN ON DRAWINGS, SPACECONTROL JOINTS AT TWICE THE SIDEWALK WIDTH, NOTTO EXCEED 10'. SPACE EXPANSION JOINTS TO COINCIDEWITH CONTROL JOINTS, NOT TO EXCEED 30'. WHERECURB IS ADJACENT TO CONCRETE WALK, JOINTS SHALLCOINCIDE. SEE SPECIFICATIONS FOR ADDITIONAL INFO.
3/4" (EXP.)JOINT1"4"1/2" R1/2" R4" CONTROL JOINT(SEE NOTE #4)
1/4" SCORED JOINT
PREPARED SUBGRADE1"PREFORMED EXPANSIONJOINT FILLERPREPARED SUBGRADECAST-IN-PLACECONCRETE SIDEWALKCAST-IN-PLACECONCRETE SIDEWALK
4" PAVEMENT SECTION
3,000 PSI CAST-IN-PLACECONCRETE SIDEWALKPREPARED SUBGRADE TO98% STANDARD PROCTOR
6x6 W1.4xW1.4 WWF
C9.1SITE DETAILS(2 OF 3) 02/16/23B D03/27/23 F04/12/23 05/17/23IJ06/02/23
COPYRIGHT c SEAMON, WHITESIDE & ASSOCIATES, INC.THIS DRAWING SHALL NOT BE REPRODUCED IN ANY MANNER OR USED FOR ANY PURPOSE WITHOUT WRITTEN PERMISSION.
GR4714DBLM/CS10/14/22DATE:
501 WANDO PARK BOULEVARD, SUITE 200 | MOUNT PLEASANT, SC 29464 | 508 RHETT STREET, SUITE 101 | GREENVILLE, SC 29601
500 W MAIN STCITY OF SPARTANBURG, SOUTH CAROLINACOKE FACILITYREDEVELOPMENT PHASE 1REVISION HISTORYDRAWN BY:CHECKED BY:SW+ PROJECT:
MOUNT PLEASANT, SC843.884.1667GREENVILLE, SC864.298.0534
WWW.SEAMONWHITESIDE.COMSUMMERVILLE, SC843.972.0710SPARTANBURG, SC864.272.1272CHARLOTTE, NC980.312.54506/1/23
SCDOT Asphalt Pavement SectionSCALE: NOT TO SCALE5Raised Crosswalk Pavement MarkingsSCALE: NOT TO SCALE6Raised CrosswalkSCALE: NOT TO SCALE7
18"Straight Curb and GutterSCALE: NOT TO SCALE1Depressed Curb EndSCALE: NOT TO SCALE2Asphalt Pavement SectionsSCALE: NOT TO SCALE3
TYPICAL DOWNSLOPE SECTION(NTS)1"
6" 12"1"
12"
NOTES:1.ALTERNATE UPSLOPE SECTION TOBE USED ONLY WHEN DRAININGAWAY FROM CURB.2.UNLESS OTHERWISE SHOWN ONDRAWINGS, LOCATE CONTROLJOINTS AT 10' INTERVALS ANDEXPANSION JOINTS AT 30'INTERVALS. WHERE CURB ISADJACENT TO CONCRETE WALK,JOINTS SHALL COINCIDE. SEESPECIFICATIONS FOR ADDITIONALINFORMATION.
1"FACE1" R1" R6"6"12"
1" R1" R6"FACE12"
PREPAREDSUBGRADE
STRUCTURAL FILL- MIN WIDTH 12"CAST-IN-PLACE CONCRETECURB & GUTTER
PREPAREDSUBGRADE
STRUCTURAL FILL- MIN WIDTH 12"CAST-IN-PLACE CONCRETECURB & GUTTER
ALTERNATE UPSLOPE SECTION(NTS)
3' MINIMUM
EDGE OF PAVEMENTPAVING NOTES1.WHERE SHOWN, SEE PLAN FOR EXPANSION AND CONTROL JOINT LOCATIONS. OTHERWISE, SEE SPECS FOR REQUIRED LOCATIONSAND SPACING.2.CONTRACTOR IS ADVISED THAT PAVING DESIGN RECOMMENDED BY GEOTECHNICAL ENGINEER IS BASED ON PREDICTED TRAFFICLOADING AND ESTABLISHED STRENGTHS FOR PROPERLY INSTALLED PAVEMENTS. CONTRACTOR MUST COORDINATE REQUIREDGEOTECHNICAL TESTING & INSPECTION TO ENSURE THAT SUBGRADE AND PAVEMENT STENGTH REQUIREMENTS ARE MET.SWA, INC. MAKES NO WARRANTY, EXPRESSED OR IMPLIED, REGARDING THE PERFORMANCE OF THE DEPICTED PAVEMENT SECTIONDESIGN. REFER TO THE GEOTECHNICAL ENGINEER FOR PAVEMENT DESIGN SECTIONS.REFER TO THE GEOTECHNICAL REPORT BY EAS PROFESSIONALS, INC. FOR PAVEMENT DESIGN SECTIONS. (SUBSURFACE EXPLORATIONAND GEOTECHNICAL ENGINEERING EVALUATION PROPOSED COKE FACILITY REDEVELOPMENT - PHASE 1, EAS-23-3018, DATED 02/24/2023).
HEAVY DUTY CONCRETEPAVEMENT SECTION(NTS)
ADA PARKING CONCRETEPAVEMENT SECTION(NTS)
COMPACTED SUBGRADE. CONTRACTOR IS TO VERIFYSUBGRADE IS PER DESIGN AND PERFORM APROOFROLL PRIOR TO PLACING BASE COURSE.
6" THICK, 4,000 PSI CAST-IN-PLACE CONCRETE PAVEMENTGEOTECHNICAL ENGINEER SHALL VERIFY CONDITION PERPROJECT SPECIFICATIONS AND JURISDICTIONALREQUIREMENTS.6" AGGREGATE BASE COURSE, GEOTECHNICALENGINEER SHALL VERIFY CONDITION PER PROJECTSPECIFICATIONS AND JURISDICTIONAL REQUIREMENTS.
COMPACTED SUBGRADE. CONTRACTOR IS TO VERIFYSUBGRADE IS PER DESIGN AND PERFORM APROOFROLL PRIOR TO PLACING BASE COURSE.
5" THICK, 4,000 PSI CAST-IN-PLACE CONCRETE PAVEMENTGEOTECHNICAL ENGINEER SHALL VERIFY CONDITION PERPROJECT SPECIFICATIONS AND JURISDICTIONALREQUIREMENTS.6" AGGREGATE BASE COURSE, GEOTECHNICALENGINEER SHALL VERIFY CONDITION PER PROJECTSPECIFICATIONS AND JURISDICTIONAL REQUIREMENTS.
PAVING NOTESSUBGRADE, BASE COURSE AND PAVEMENT CONSTRUCTION METHODS SHALL MEET THE MINIMUM REQUIREMENTS OF THESCDOT "STANDARD SPECIFICATIONS FOR HIGHWAY CONSTRUCTION", LATEST EDITION.SWA, INC. MAKES NO WARRANTY, EXPRESSED OR IMPLIED, REGARDING THE PERFORMANCE OF THE DEPICTED PAVEMENTSECTION DESIGN. REFER TO THE GEOTECHNICAL ENGINEER FOR PAVEMENT DESIGN SECTIONS.REFER TO THE GEOTECHNICAL REPORT BY EAS PROFESSIONALS, INC. FOR PAVEMENT DESIGN SECTIONS. (SUBSURFACEEXPLORATION AND GEOTECHNICAL ENGINEERING EVALUATION PROPOSED COKE FACILITY REDEVELOPMENT - PHASE 1,EAS-23-3018, DATED 02/24/2023).
2.5" ASPHALTIC CONCRETEINTERMEDIATE COURSE8" AGGREGATE BASE COURSE, GEOTECHNICALENGINEER SHALL VERIFY CONDITION PER PROJECTSPECIFICATIONS AND JURISDICTIONAL REQUIREMENTS.COMPACTED SUBGRADE. CONTRACTOR IS TO VERIFYSUBGRADE IS PER DESIGN AND PERFORM APROOFROLL PRIOR TO PLACING BASE COURSE.HEAVY DUTY ASPHALT PAVEMENT SECTION(NTS)
2" ASPHALTIC CONCRETESURFACE COURSE.
Concrete Pavement SectionsSCALE: NOT TO SCALE4 ITEM:SUBGRADEBASE COURSETACK COATINTERMEDIATE(BINDER) COURSESURFACE COURSE
MATERIAL:PREPARED IN-SITU SUBSOILORSTRUCTURAL FILLHOT MIX ASPHALTAGGREGATE BASE COURSE(TYPE A)ASPHALT BINDER OREMULSIFIED ASPHALTHOT MIX ASPHALTINTERMEDIATE COURSE(TYPE B)HOT MIX ASPHALT SURFACECOURSE(TYPE B)
SCDOT SPECIFICATION SECTION:SECTION 208SECTION 310SECTION 401SECTION 402SECTION 403TACK COATSURFACE COURSEINTERMEDIATE COURSE2.0"8"2.5"BASE COURSESUBGRADE
NOTES:1. SEE REFERENCED SCDOT STANDARD SPECIFICATIONSECTIONS FOR MATERIAL, EQUIPMENT, AND CONSTRUCTIONREQUIREMENTS.2. CONTRACTOR IS ADVISED THAT PAVING DESIGNRECOMMENDED BY GEOTECHNICAL ENGINEER IS BASED ONPREDICTED TRAFFIC LOADING AND ESTABLISHED STRENGTHSFOR PROPERLY INSTALLED PAVEMENTS. CONTRACTOR MUSTCOORDINATE REQUIRED GEOTECHNICAL TESTING & INSPECTIONTO ENSURE THAT SUBGRADE AND PAVEMENT STRENGTHREQUIREMENTS ARE MET.
26' DRIVEWAY
VARIES(SEE PLAN)SPEED HUMP PAVEMENTMARKING (TYP)
6'6' STAMPED CONCRETE
12" WHITEMARKINGS12"
FACE OF CURB(TYP)
DIRECTION OF TRAVELFACE OF CURB(TYP)CROSSWALK CONCRETEPAVEMENT (TYP)ADA DETECTABLE WARNINGSURFACE (TYP)
VARIES(SEE PLAN)
CL AA NOTE:1.SEE PLANS FOR TYPE OF ADA PEDESTRIAN RAMP (IF REQUIRED)
S1-1 & W16-7P(IF SPACE ALLOWS)
W17-1(IF SPACE ALLOWS)S1-1 & W16-7PW17-1(OPTIONAL LOCATION IFSPACE NOT PERMITTING)
BIKE RACKSSCALE: NOT TO SCALE10
6"TOP OF CURBTOP OF RAISED CROSSWALK TOBE FLUSH WITH TOP OF CURB(MAX 1:50 CROSS SLOPE)
10'ASPHALT DRIVE(SEE DETAILS FORPAVEMENT SECTIONS)12:1 MAX SLOPE(TYP)6' 6'A - A SECTIONSIGNS DESCRIPTIONS:S1-1 (SCHOOL CROSSING)W17-1 (SPEED HUMP SIGN)W16-7P (DIAGONAL DOWNWARD POINTING ARROW PLAQUE)CLCL
NOTE:1. POSITION TRANSVERSE MARKINGS IN LANES SO AS NOT TO BE IN WHEELPATH2. DO NOT CONTINUE PAINT INTO GUTTER
6'(OR AS INDICATEDON PLANS)
LENGTH VARIES -SEE SITE PLAN8" SOLIDWHITE
PAINTED CROSSWALKSCALE: NOT TO SCALE8BollardSCALE: NOT TO SCALE9
3'-0"14" MINIMUM CROWN
6"6" NOTES:1. PREPARE POST FOR PAINTING AS INSTRUCTED BY PAINT MANUFACTURER.2. PAINT WITH OIL BASED EPOXY ENAMEL: TWO COATS BEFORE INSTALLATION, ONE COAT AFTER. COLOR ASINSTRUCTED BY ENGINEER OR ARCHITECT.3. LOCATE 24" FROM STRUCTURE TO BE PROTECTED, UNLESS OTHERWISE INDICATED.4. SEE REFERENCED SPECIFICATION SECTIONS FOR GENERAL, PRODUCT, AND EXECUTION REQUIREMENTS.
FILL PIPE WITH CONCRETE6" DIAMETER SCHEDULE 40 STEEL PIPE WITHGRAY POLYETHYLENE BOLLARD SLEEVE(CONTACT OWNER PRIOR TO ORDERING)FINISHED GRADECAST-IN-PLACE CONCRETE
6"2'-6"6"
2" ASPHALTIC CONCRETEINTERMEDIATE COURSE6" AGGREGATE BASE COURSE, GEOTECHNICALENGINEER SHALL VERIFY CONDITION PER PROJECTSPECIFICATIONS AND JURISDICTIONAL REQUIREMENTS.COMPACTED SUBGRADE. CONTRACTOR IS TO VERIFYSUBGRADE IS PER DESIGN AND PERFORM APROOFROLL PRIOR TO PLACING BASE COURSE.STANDARD DUTY ASPHALT PAVEMENT SECTION(NTS)
1.5" ASPHALTIC CONCRETESURFACE COURSE.
C9.2SITE DETAILS(3 OF 3) 02/16/23B D03/27/23 F04/12/23 05/17/23IJ06/02/23
COPYRIGHT c SEAMON, WHITESIDE & ASSOCIATES, INC.THIS DRAWING SHALL NOT BE REPRODUCED IN ANY MANNER OR USED FOR ANY PURPOSE WITHOUT WRITTEN PERMISSION.
GR4714DBLM/CS10/14/22DATE:
501 WANDO PARK BOULEVARD, SUITE 200 | MOUNT PLEASANT, SC 29464 | 508 RHETT STREET, SUITE 101 | GREENVILLE, SC 29601
500 W MAIN STCITY OF SPARTANBURG, SOUTH CAROLINACOKE FACILITYREDEVELOPMENT PHASE 1REVISION HISTORYDRAWN BY:CHECKED BY:SW+ PROJECT:
MOUNT PLEASANT, SC843.884.1667GREENVILLE, SC864.298.0534
WWW.SEAMONWHITESIDE.COMSUMMERVILLE, SC843.972.0710SPARTANBURG, SC864.272.1272CHARLOTTE, NC980.312.54506/1/23
Concrete Stairs & Handrail DetailSCALE: NOT TO SCALE4NOTES:1.HANDRAIL MUST BE 1-1/2" IN DIAMETER STAINLESS STEEL. SUBMIT HANDRAIL SHOP DRAWINGS FOR APPROVAL PRIOR TO FABRICATION.2.RAIL HEIGHT MUST ALWAYS BE 36" ABOVE AND PARALLEL TO WALKING SURFACE.3.RAIL TO BE ON BOTH SIDES OF STAIRS.ELEVATION
12" HIGH CONCRETE CHEEKWALL
1 12" DIAMETERCONTINUOUSSEE STAIR DETAIL FORCONSTRUCTION INFORMATION18" MIN.12" MIN.
12" MIN.18" MIN.12" MIN.(TYP.)12" CHAMFER (TYP.)CORE DRILL AND EPOXY POSTCONCRETE CHEEK WALLMITER RAILING AS SHOWN36" (TYP.)12" (TYP.)24" (TYP.)36" (TYP.)
1.5" DIAMETER STAINLESS STEEL RAILING PER ADA GUIDELINES.PROVIDE RAILING SHOP DRAWINGS FOR REVIEW
C10.0GRADING &DRAINAGEDETAILS (1 OF2)
02/16/23B D03/27/23 F04/12/23 05/17/23IJ06/02/23
COPYRIGHT c SEAMON, WHITESIDE & ASSOCIATES, INC.THIS DRAWING SHALL NOT BE REPRODUCED IN ANY MANNER OR USED FOR ANY PURPOSE WITHOUT WRITTEN PERMISSION.
GR4714DBLM/CS10/14/22DATE:
501 WANDO PARK BOULEVARD, SUITE 200 | MOUNT PLEASANT, SC 29464 | 508 RHETT STREET, SUITE 101 | GREENVILLE, SC 29601
500 W MAIN STCITY OF SPARTANBURG, SOUTH CAROLINACOKE FACILITYREDEVELOPMENT PHASE 1REVISION HISTORYDRAWN BY:CHECKED BY:SW+ PROJECT:
MOUNT PLEASANT, SC843.884.1667GREENVILLE, SC864.298.0534
WWW.SEAMONWHITESIDE.COMSUMMERVILLE, SC843.972.0710SPARTANBURG, SC864.272.1272CHARLOTTE, NC980.312.54506/1/23
123
6 5
STORM DRAINAGE PIPE TRENCH(NOT TO SCALE)COMBINATION INLET (SCDOT TYPE 1) (CI-1)(NOT TO SCALE)
CATCH BASIN (CB)(NOT TO SCALE)CATCH BASIN FRAME & GRATE (CB)(NOT TO SCALE)
COMINATION INLET FRAME & GRATE (CI-1)(NOT TO SCALE)
4"
8YARD INLET (YI)(NOT TO SCALE)
7JUNCTION BOX (JB)(NOT TO SCALE)4PRECAST HEADWALL (HW)(NOT TO SCALE)REVE 7003-110-026DWG NO.1 OF 1SHEET1:20SCALEDWG SIZEA3130 VERONA AVEBUFORD, GA 30518PHN (770) 932-2443FAX (770) 932-2490www.nyloplast-us.com15 IN INLINE DRAIN QUICK SPEC INSTALLATION DETAILTITLEPROJECT NO./NAMEMATERIALDATEREVISED BY04-03-06DATEEBCDRAWN BY03-15-16NMH
NYLOPLAST 15" INLINE DRAIN: 2715AG _ _ X(1, 2) INTEGRATED DUCTILE IRONFRAME & GRATE TO MATCH BASIN O.D.
THIS PRINT DISCLOSES SUBJECT MATTER IN WHICHNYLOPLAST HAS PROPRIETARY RIGHTS. THE RECEIPTOR POSSESSION OF THIS PRINT DOES NOT CONFER,TRANSFER, OR LICENSE THE USE OF THE DESIGN ORTECHNICAL INFORMATION SHOWN HEREINREPRODUCTION OF THIS PRINT OR ANY INFORMATIONCONTAINED HEREIN, OR MANUFACTURE OF ANYARTICLE HEREFROM, FOR THE DISCLOSURE TO OTHERSIS FORBIDDEN, EXCEPT BY SPECIFIC WRITTENPERMISSION FROM NYLOPLAST.
8" MIN THICKNESS GUIDELINEMINIMUM PIPE BURIALDEPTH PER PIPEMANUFACTURERRECOMMENDATIONINVERT ACCORDING TOPLANS/TAKE OFF(3) VARIOUS TYPES OF INLET & OUTLET ADAPTERS AVAILABLE:4" - 15" FOR CORRUGATED HDPE (ADS N-12/HANCOR DUAL WALL,ADS/HANCOR SINGLE WALL), N-12 HP, PVC SEWER (EX: SDR 35),PVC DWV (EX: SCH 40), PVC C900/C905, CORRUGATED & RIBBED PVC(CORRUGATED HDPE SHOWN)
(B)
TRAFFIC LOADS: CONCRETE SLAB DIMENSIONS ARE FOR GUIDELINEPURPOSES ONLY. ACTUAL CONCRETE SLAB MUST BE DESIGNEDTAKING INTO CONSIDERATION LOCAL SOIL CONDITIONS, TRAFFICLOADING, & OTHER APPLICABLE DESIGN FACTORS.
THE BACKFILL MATERIAL SHALL BE CRUSHED STONE OR OTHERGRANULAR MATERIAL MEETING THE REQUIREMENTS OF CLASS I,CLASS II, OR CLASS III MATERIAL AS DEFINED IN ASTM D2321.BEDDING & BACKFILL FOR SURFACE DRAINAGE INLETS SHALL BEPLACED & COMPACTED UNIFORMLY IN ACCORDANCE WITH ASTM D2321.
©2013 NYLOPLAST
1 - GRATES/SOLID COVER SHALL BE DUCTILE IRON PER ASTM A536 GRADE 70-50-05, WITH THE EXCEPTION OF THE BRONZE GRATE.2 - FRAMES SHALL BE DUCTILE IRON PER ASTM A536 GRADE 70-50-05.3 - DRAINAGE CONNECTION STUB JOINT TIGHTNESS SHALL CONFORM TO ASTM D3212 FOR CORRUGATED HDPE (ADS N-12/HANCOR DUAL WALL), N-12 HP, & PVC SEWER.4 - DIMENSIONS ARE FOR REFERENCE ONLY. ACTUAL DIMENSIONS MAY VARY.5 - DIMENSIONS ARE IN INCHES6 - SEE DRAWING NO. 7001-110-275 FOR ADS N-12 & HANCOR DUAL WALL BELL INFORMATION & DRAWING NO. 7001-110-364 FOR N-12 HP BELL INFORMATION.
18" MIN WIDTH GUIDELINE
C10.1GRADING &DRAINAGEDETAILS (2 OF2)
02/16/23B D03/27/23 F04/12/23 05/17/23IJ06/02/23
COPYRIGHT c SEAMON, WHITESIDE & ASSOCIATES, INC.THIS DRAWING SHALL NOT BE REPRODUCED IN ANY MANNER OR USED FOR ANY PURPOSE WITHOUT WRITTEN PERMISSION.
GR4714DBLM/CS10/14/22DATE:
501 WANDO PARK BOULEVARD, SUITE 200 | MOUNT PLEASANT, SC 29464 | 508 RHETT STREET, SUITE 101 | GREENVILLE, SC 29601
500 W MAIN STCITY OF SPARTANBURG, SOUTH CAROLINACOKE FACILITYREDEVELOPMENT PHASE 1REVISION HISTORYDRAWN BY:CHECKED BY:SW+ PROJECT:
MOUNT PLEASANT, SC843.884.1667GREENVILLE, SC864.298.0534
WWW.SEAMONWHITESIDE.COMSUMMERVILLE, SC843.972.0710SPARTANBURG, SC864.272.1272CHARLOTTE, NC980.312.54506/1/23
PLAN VIEW
SECTION 'A-A'
PIPE OUTLET TO FLAT AREA WITH NO DEFINED CHANNEL:OUTLETPIPEDIAMETER,2 MIN
MAXIMUM TAILWATER CONDITON:
d = 1.5 TIMES THE MAXIMUMSTONE DIAMETER BUT NOT LESSTHAN 6-INCHESOUTLETPIPEDIAMETER,1L
d = 1.5 TIMES THE MAXIMUMSTONE DIAMETER BUT NOT LESSTHAN 6-INCHES
3K BAYSEPARATOR SYSTEM DETAIL3(NOT TO SCALE)
RIPRAP APRON DETAIL2(NOT TO SCALE)
60" Ø PRIMARYMANHOLE98"
62"
BAYSAVER BAYSEPARATOR 3K LEFT HAND UNITNTS
60" Ø STORAGE MANHOLE24" Ø CASTING UNLESS OTHERWISEREQUIRED BY APPROVAL AGENCY
24" Ø CASTING UNLESSOTHERWISE REQUIREDBY APPROVAL AGENCY
MAR MAC JOINT COUPERSAA
B B
ODUMPN!ETSAWDRASNIOTWATWRESYA
EASTJORDANIRONWORKS
MADENUSAI
BAYSAVERwww.BaySaver.comTECHNOLOGIES, INC.
ODUMPN!ETSAWDRASNIOTWATWRESYA
EASTJORDANIRONWORKS
MADENUSAI
BAYSAVERwww.BaySaver.comTECHNOLOGIES, INC.
26"
GENERAL NOTES:1.MANHOLES SHOWN REPRESENT STANDARD PRECAST STRUCTURES PROVIDED BY OTHERS.2.SEAL THE CONNECTING PIPES INTO THE STORAGE MANHOLE USING RUBBER BOOTS/GASKETS.3.THE BAYSAVER SEPARATION SYSTEM INCLUDES THE SEPARATOR UNIT, (2) CONNECTING PIPES, (2) FERNCO COUPLERS,(1)REDUCER/ADAPTER, (2) MAR MAC COUPLERS4.SEE BAYSAVER SPECIFICATIONS AND INSTALLATION INSTRUCTIONS FOR FURTHER DETAIL.5.USE NON-SHRINK GROUT TO SEAL BAYSEPARATOR INTO THE PRIMARY MANHOLE.6.BACKFILL: CLASS I, II OR III BACKFILL SHOULD BE USED TO AN ELEVATION OF AT LEAST 6" OVER THE CROWN OF THE SEPARATOR UNIT.7.24" COVER REQUIRED FOR TRAFFIC RATED SURFACE.8.BAYSEPARATOR IS PROTECTED BY US PATENT NO. 5,746,911
PRIMARY MANHOLE W/ SOLID LIDSTORAGE MANHOLE30" OUTLET PIPE
STRUCTURE A02 PER PLAN
36" x 30" REDUCER
30" INLET PIPE
PROFILE A-ANTSPROFILE B-BNTS SUMP: 704.0
36"REDUCER/ADAPTERBYPASS PLATE
TEE PIPESPRIMARY MANHOLE(STORAGE MANHOLE NOTSHOWN FOR CLARITY)STORAGE MANHOLE(PRIMARY MANHOLE NOTSHOWN FOR CLARITY)48"RUBBER BOOTS
FERNCO COUPLER10.75" OD CONNECTING PIPE
19"INV: 708.0SUMP: 704.0
48"
BAYSEPARATOR UNIT
26"48"96"BACKFILL60"
60" STEP (TYP)ORIENT BELOW GRATE OPENINGSTEP (TYP) COVER: 722.50
30" Ø RCP - INV IN: 712.0030" Ø RCP - INV OUT: 712.00
RIM: 722.50±
180°
3K BAYSEPARATOR SYSTEM NOTES2(NOT TO SCALE)©2022 ADS, INC.
PROJECT INFORMATIONADS SALES REP:ENGINEEREDPRODUCTMANAGER:PROJECT NO:COKE REDEVELOPMENTSPARTANBURG, SC
RYAN HORNISH864-905-5854RYAN.HORNISH@ADSPIPE.COMAdvanced Drainage Systems, Inc.BRENT HUTCHINSON864-399-0545BRENT.HUTCHINSON@ADSPIPE.COM
BAYSAVER BAYSEPARATOR SPECIFICATIONSMATERIALS AND DESIGNA.CONCRETE STRUCTURES SHALL BE DESIGNED FOR H-20 TRAFFIC LOADING AND APPLICABLE SOIL LOADS OR AS OTHERWISE DETERMINED BY ALICENSED PROFESSIONAL ENGINEER. THE MATERIALS AND STRUCTURAL DESIGN OF THE DEVICES SHALL BE PER ASTM C857 AND ASTM C858.1.THE MINIMUM COMPRESSIVE STRENGTH OF THE CONCRETE IN THE MANHOLE BASE, RISER, AND TOP SECTIONS SHALL BE 4000 PSI.2.THE MINIMUM WALL THICKNESS SHALL BE ONE TWELFTH OF THE INTERNAL DIAMETER OF THE RISER OF LARGEST CONE DIAMETER.3.CEMENT SHALL CONFORM TO THE REQUIREMENTS FOR PORTLAND CEMENT OF SPECIFICATION C150.4.AGGREGATES SHALL CONFORM TO SPECIFICATION C33, EXCEPT THAT THE REQUIREMENT FOR GRADATION SHALL NOT APPLY.5.REINFORCEMENT SHALL CONSIST OF WIRE CONFORMING TO SPECIFICATION A82 OR SPECIFICATION A496, OF WIRE FABRIC CONFORMINGTO SPECIFICATION A185 OR SPECIFICATION A497, OR OF BARS OF GRADE 40 STEEL CONFORMING TO SPECIFICATION A615/A615M.6.THE ACCESS COVER SHALL BE DESIGNED FOR HS20-44 TRAFFIC LOADING AND SHALL PROVIDE A MINIMUM 30 INCH CLEAR OPENING.7.ALL JOINTS SHALL BE WATERPROOF WITH WRAPPED GASKETS OR SEALED WITH A MASTIC TREATMENT.8.ANY GROUT USED WITHIN THE SYSTEM SHALL MEET THE ASTM C 1107 "STANDARD SPECIFICATION FOR PACKAGED DRY,HYDRAULIC-CEMENT GROUT (NON-SHRINK)". GRADES A, B AND C AT A POURABLE AND PLASTIC CONSISTENCY AT 70°F. CRD C 621 "CORPSOF ENGINEERS SPECIFICATION FOR NON-SHRINK GROUT."9.STORAGE MANHOLE CONNECTOR PIPES SHALL BE EQUIPPED WITH A SEAL GASKET THAT MEETS OR EXCEEDS MATERIAL SPECIFICATIONSOF ASTM C-923 OR OTHER LOCALLY APPROVED METHODS.B.THE SEPARATOR STRUCTURE SHALL BE SUBSTANTIALLY CONSTRUCTED OF HDPE OR EQUIVALENT CORROSION RESISTANT MATERIAL MEETINGASTM D330, ASTM F412, AND ASTM C-425.C.PIPES WITHIN THE UNIT, (I.E., TEE PIPES, CONNECTOR PIPES AND DOWN PIPES) SHALL BE CONSTRUCTED OF AT LEAST SDR 32.5 HDPE PIPE OFSTANDARD ASTM F412.D.PIPE AND FITTING MATERIAL SHALL BE HIGH DENSITY POLYETHYLENE MEETING ASTM D330 MINIMUM CELL CLASSIFICATION 335400C FOR 24-INCHTHROUGH 60-INCH DIAMETERS. THE 24- THROUGH 60-INCH PIPE MATERIAL SHALL BE SLOW CRACK RESISTANT HDPE MATERIAL, EVALUATED USINGTHE SINGLE POINT NOTCHED CONSTANT TENSILE LOAD (SP-NCTL) TEST.PERFORMANCEA.THE STORMWATER TREATMENT UNIT SHALL BE AN ONLINE UNIT CAPABLE OF CONVEYING 100% OF THE DESIGN PEAK FLOW.B.THE BAYSEPARATOR UNIT SHALL BE DESIGNED TO REMOVE AT LEAST 80% OF THE SUSPENDED SOLIDS LOAD ON AN ANNUAL AGGREGATEREMOVAL BASIS. SAID REMOVAL SHALL BE BASED ON FULL-SCALE THIRD PARTY TESTING USING F-95 MEDIA GRADATION (MANUFACTURED BY USSILICA) OR EQUIVALENT. SAID FULL SCALE TESTING SHALL HAVE INCLUDED SEDIMENT CAPTURE BASED ON ACTUAL TOTAL MASS COLLECTED BYTHE STORMWATER TREATMENT UNIT(S).C.THE STORMWATER TREATMENT UNIT SHALL CONSIST OF ONE (1) PREFABRICATED SEPARATOR STRUCTURE, ONE (1) ONLINE COARSE SEDIMENTCAPTURE STRUCTURE, AND ONE (1) OFFLINE SEDIMENT AND FLOATABLE CAPTURE STRUCTURE. THE SEPARATOR STRUCTURE SHALL BESUBSTANTIALLY CONSTRUCTED OF HDPE OR EQUIVALENT CORROSION RESISTANT MATERIAL. THE OFFLINE SEDIMENT STORAGE STRUCTUREMUST PROVIDE FOR OFFLINE SEDIMENT STORAGE OF SEDIMENTS AND FLOATABLES THAT ARE ISOLATED FROM HIGH INTENSITY STORMS.D.THE STORMWATER TREATMENT UNIT(S) HEAD LOSS AT THE PEAK DESIGN FLOW RATE SHALL NOT EXCEED THE HEAD LOSS SPECIFIED BY THEENGINEER.E.THE UNIT SHALL BE DESIGNED TO REMOVE SEDIMENT PARTICLES AS WELL AS FLOATING OILS AND DEBRIS.MANUFACTURERA.THE STORMWATER TREATMENT UNIT(S) SHALL BE OF A BASIC DESIGN THAT HAS BEEN INSTALLED AND USED SUCCESSFULLY FOR A MINIMUM OF 5YEARS.B.EACH STORMWATER TREATMENT SYSTEM SHALL BE A BAYSEPARATOR SYSTEM AS MANUFACTURED BY BAYSAVER, LLC, 1030 DEER HOLLOW DR.,MOUNT AIRY, MD 21771, PHONE (301) 829-6470, FAX (301-829-3747, TOLL FREE 1-800-229-7283 (1-800-BAYSAVER), EMAIL INFO@BAYSAVER.COMPROTECTED UNDER US PATENT NUMBER 5746911
BAYSEPARATOR MAINTENANCEBAYSEPARATOR SYSTEMS MUST BE INSPECTED AND MAINTAINED PERIODICALLY. INSPECTION IS MADE BY CHECKING THE DEPTH OFSEDIMENT IN EACH MANHOLE WITH A GRADE STICK OR SIMILAR DEVICE. MAINTENANCE IS REQUIRED WHEN THE SEDIMENT DEPTH INEITHER MANHOLE EXCEEDS 2 FEET. MINIMUM INSPECTION IS RECOMMENDED TWICE A YEAR TO MAINTAIN OPERATION AND FUNCTION OFBAYSAVER.MAINTENANCE CONSISTS OF THE FOLLOWING:A. STORAGE MANHOLE1.REMOVE THE ENTIRE VOLUME OF THE CONTAMINATED WATER BY VACUUM TRUCK.2.CLEAN THE MANHOLE WALLS AND FLUSH OUT THE MANHOLE USING A HIGH PRESSURE HOSE AND REMOVE FLUSHING WATER BYVACUUM TRUCK. MAKE CERTAIN MANHOLE IS CLEAN.B. PRIMARY MANHOLE1.USING A SUBMERSIBLE PUMP, PUMP THE CLEAN WATER FROM THE CENTER OF THE MANHOLE DIRECTLY INTO THE EMPTY STORAGEMANHOLE UNTIL THE WATER LEVEL FALLS TO 1 FOOT ABOVE THE SEDIMENT LAYER.2.REMOVE THE SETTLED SEDIMENT AND REMAINING WATER BY VACUUM TRUCK.3.CLEAN THE MANHOLE WALLS AND FLUSH OUT THE MANHOLE USING A HIGH PRESSURE HOSE AND REMOVE FLUSHING WATER BYVACUUM TRUCK. MAKE CERTAIN MANHOLE IS CLEAN.4.CONTAMINATED MATERIAL REMOVED FROM THE MANHOLES MUST BE DISPOSED OF RESPONSIBLY AND LEGALLY BY THE OPERATOROF THE VACUUM TRUCK.BAYSEPARATOR INSTALLATION NOTES1.EXCAVATION MUST PROVIDE ADEQUATE SPACE TO CONNECT INLET AND OUTLET PIPES TO STORAGE MANHOLE AND BAYSEPARATORUNIT. INSTALL PRECAST DROP STRUCTURES ON SOLID GROUND AS VERIFIED BY A GEOTECHNICAL ENGINEER.2.VERIFY THE SUBGRADE ELEVATION AGAINST THE MANHOLE DIMENSIONS AND CONNECTING STORM DRAIN INVERTS.3.MAKING SURE THE BASES ARE LEVEL AND THE STORAGE MANHOLE OPENINGS ARE ALIGNED WITH THE SEPARATOR UNIT, INSTALLPRIMARY AND STORAGE MANHOLES. INSTALL WATERTIGHT GASKETS ON BASE UNITS AND COAT WITH LUBRICATING GREASE (IFREQUIRED). INSTALL ADDITIONAL MANHOLE SECTIONS AS REQUIRED. SEAL LIFT HOLES WITH NON-SHRINK GROUT.4.BACKFILL BASE SECTIONS OF MANHOLES TO INVERT OF STORAGE MANHOLE CONNECTING PIPES. USING APPROVED BACKFILLMATERIAL, BACKFILL AND COMPACT IN 8 INCH LIFTS. BACKFILL AND COMPACTION SHOULD BE MONITORED BY A GEOTECHNICALENGINEER.5.INSTALL BAYSEPARATOR UNIT AND CONNECTING PIPES. SEAL ALL CONNECTING JOINTS AND INSTALL SEPARATOR HDPEREDUCER/ADAPTER. CUT EXCESS LENGTH OFF CONNECTING PIPES INSIDE STORAGE MANHOLE.6.BACKFILL SEPARATOR UNIT AND MANHOLES. AREAS NOT ACCESSIBLE TO COMPACTION EQUIPMENT MUST BE BACKFILLED WITH #57,#7, OR PEA GRAVEL.7.INSTALL AND SET MANHOLE COVER GRADE ADJUSTMENT RINGS AS NECESSARY.8.INSTALL AND SET MANHOLE FRAME AND COVER UNITS.
C11.0WATERDETAILS H05/04/2302/16/23BC02/21/23D03/27/23E03/30/23F04/12/23 05/17/23IJ06/02/23
COPYRIGHT c SEAMON, WHITESIDE & ASSOCIATES, INC.THIS DRAWING SHALL NOT BE REPRODUCED IN ANY MANNER OR USED FOR ANY PURPOSE WITHOUT WRITTEN PERMISSION.
GR4714DBLM/CS10/14/22DATE:
501 WANDO PARK BOULEVARD, SUITE 200 | MOUNT PLEASANT, SC 29464 | 508 RHETT STREET, SUITE 101 | GREENVILLE, SC 29601
500 W MAIN STCITY OF SPARTANBURG, SOUTH CAROLINACOKE FACILITYREDEVELOPMENT PHASE 1REVISION HISTORYDRAWN BY:CHECKED BY:SW+ PROJECT:
MOUNT PLEASANT, SC843.884.1667GREENVILLE, SC864.298.0534
WWW.SEAMONWHITESIDE.COMSUMMERVILLE, SC843.972.0710SPARTANBURG, SC864.272.1272CHARLOTTE, NC980.312.54506/1/23 34
5
TYPICAL VALVE BOX(NOT TO SCALE)CONCRETE THRUST BLOCK DETAIL(NOT TO SCALE)
TYPICAL TRENCHING DETAIL(NOT TO SCALE)
1SPARTANBURG WATER GENERAL NOTES(NOT TO SCALE)
6WATER LINE / STORM DRAIN CROSSING(NOT TO SCALE)
DUCTILE IRONFLANGE
THRUST BLOCKCONCRETE THRUST BLOCKMINIMUM 3/4" ROD WITHBITUMINOUS COATING ONBOLTS.FINISH FLOOR
PER NFPA 24 PIPE JOINTS SHALL NOT BE LOCATED DIRECTLY UNDERFOOTINGS; PIPE UNDER FOOTING TO BE MIN 12" BELOW FOUNDATION,CONFIRM WITH STRUCTURAL ENGINEER.
PER 2019 NFPA 24-12.2.6 WHERE PIPING GOESTHROUGH HOLES IN THE FOUNDATION OR FLOORING,THE HOLE SHALL BE 4" NOMINALLY LARGER THAN THEPIPE DIAMETER (FOR PIPE 4" AND LARGER) THUS MEET2019 NFPA 13-9.3.4.2. UNLESS 2019 NFPA 13-9.3.4.3 OR9.3.4.10 ARE MET.
7SPRINKLER RISER DETAIL(NOT TO SCALE)
5" STORZ4" GALVANIZED90° ELBOW4" GALVANIZEDTHREADED PIPE(SCH. 40)
4" WAFERCHECK
4" 90° ELBOW(FLANGED)
AUTOMATIC DRIP3' - 0"MINIMUM
REMOTE FIRE DEPARTMENT CONNECTION(FDC) NOTE:1.CONTRACTOR TO INSTALL 5" STORZFITTING AT REMOTE FIRE DEPARTMENTCONNECTION (FDC) AS SHOWN ONPLANS. CONTRACTOR TO CONFIRMCOMPLIANCE WITH CITY OFSPARTANBURG BUILDING DEPARTMENT.2.ALL CURBING IN FRONT OF SITE FIREPROTECTION SERVICES (REMOTE FDCAND FIRE HYDRANTS) SHALL BE BEPAINTED RED WITH NO PARKING INWHITE TEXT ALONG THE FACE OF CURB.8REMOTE FIRE DEPARTMENT CONNECTION DETAIL(NOT TO SCALE)
2FIRE HYDRANT ASSEMBLY(NOT TO SCALE)FIRE HYDRANT ASSEMBLY NOTE: 1.PER THE STATE FIRE MARSHAL OFFICE, THE CENTER OF THE LOWEST OUTLETSHALL BE A MINIMUM OF 18" ABOVE THE GROUND.2.CONTRACTOR TO COORDINATE FIRE HYDRANT INSTALLATION WITH SWSENGINEERING FIELD TECHNICIAN PRIOR TO CONSTRUCTION.
C11.1SEWERDETAILS 02/16/23BC02/21/23D03/27/23 F04/12/23G04/27/2305/17/23IJ06/02/23
COPYRIGHT c SEAMON, WHITESIDE & ASSOCIATES, INC.THIS DRAWING SHALL NOT BE REPRODUCED IN ANY MANNER OR USED FOR ANY PURPOSE WITHOUT WRITTEN PERMISSION.
GR4714DBLM/CS10/14/22DATE:
501 WANDO PARK BOULEVARD, SUITE 200 | MOUNT PLEASANT, SC 29464 | 508 RHETT STREET, SUITE 101 | GREENVILLE, SC 29601
500 W MAIN STCITY OF SPARTANBURG, SOUTH CAROLINACOKE FACILITYREDEVELOPMENT PHASE 1REVISION HISTORYDRAWN BY:CHECKED BY:SW+ PROJECT:
MOUNT PLEASANT, SC843.884.1667GREENVILLE, SC864.298.0534
WWW.SEAMONWHITESIDE.COMSUMMERVILLE, SC843.972.0710SPARTANBURG, SC864.272.1272CHARLOTTE, NC980.312.54506/1/23
13
6
4
MANHOLE ENTRANCE "BOOT"(NOT TO SCALE)
TYPICAL TRENCHING DETAIL(NOT TO SCALE)
SERVICE LINE TAP TO MANHOLE(NOT TO SCALE)CASING PIPE BORE AND JACK DETAIL(NOT TO SCALE)
CARRIER PIPE INSTALLATION IN CASING(NOT TO SCALE)
TYPICAL PAVEMENT REPAIR DETAIL(NOT TO SCALE)(NOT TO SCALE)(NOT TO SCALE)STANDARD MANHOLE FRAME AND COVER2(NOT TO SCALE)IMPROVED DITCH BEDDING DETAIL
11SEWER CLEAN-OUT(NOT TO SCALE)12SEWER CLEAN-OUT COVER(NOT TO SCALE)
789
STANDARD PRECAST MANHOLE(NOT TO SCALE)10
SERVICE LINE CONNECTION TO SEWER MAIN(NOT TO SCALE)15DOGHOUSE MANHOLE(NOT TO SCALE)13TYPICAL OUTSIDE DROP MANHOLE(NOT TO SCALE)16STANDARD PRECAST MANHOLE JOINT DETAIL(NOT TO SCALE)14
MEP TO VERIFY CAPACITYREQUIREMENTS5GREASE TRAP INTERCEPTOR(NOT TO SCALE)GREASE TRAP MANHOLE TOBE SET MIN. 4" ABOVE GRADEIF INSTALLED IN LANDSCAPE
EXISTINGWAREHOUSEBUILDINGEXISTINGWAREHOUSEBUILDING
EXISTING COKEBUILDING
IE:701.0
YI
VAN
357.6' ROAD FRONTAGE
(5) CORF
(5) CORF
(38) Vib mis(28) Vib mis(3) Dis mnv(3) Dis mnv(56) ILVN(3) Dis mnv(6) Dis mnv(6) Dis mnv(3) Dis mnv(7) Dis mnv
(14) ILVN(9) ILVN
(11) Ile sha
(9) Ile sha
(76) LMBB(103) LMBB(117) LMBB(49) LMBB(31) LMBB(56) LMBB(57) LMBB(37) LMBB
(109) LMBB
(3) Dis mnv(3) Dis mnv(3) Dis mnv
(19) Dis mnv(9) Dis mnv(7) Dis mnv
(7) Dis mnv(48) LMBB(5) Dis mnv
(5) Dis mnv
(219) Hem hap
(8) Dis mnv
(54) Hem hap
(39) LMBB
(8) ILVN
(13) ULMB
(2) TAXD(12) Ace abz
(5) Taxd
(17,600 sf) SOD2
EXISTING VEGETATION TOREMAIN UNTIL PHASE 2CONSTRUCTION
15' PHASE 2BUFFERYARD 3
EXISTING VEGETATION TOREMAIN UNDISTURBED
15' PHASE 2BUFFERYARD 3
(38,000 sf) SEED
(9,100 sf) SEED
6' TALL STOCKADE FENCE(FINISHED SIDE TO FACEPROPERTY ADJOINER)189.5'(5) MagEXISTING VEGETATION TOREMAIN UNDISTURBED
153060SCALE: 1" = 30'0
SEWN R
Know what'sbelow.before you dig.CallL1.0LANDSCAPEPLANA10/14/22 02/16/23B D03/27/23 F04/12/23 05/17/23IJ06/02/23 STREET FRONTAGE PLANTING REQUIREMENTS:±358 LF OF ROAD FRONTAGE1 CANOPY TREE / 100 LF = 4 2 ORNAMENTAL TREES / 100 LF (2 IN PLACE OF CANOPY TREE WHEN NEEDED) = 78 SMALL EVERGREEN SHRUBS / 100 LF = 29STREET FRONTAGE PLANTING PROVIDED:CANOPY TREE= 3 ORNAMENTAL TREES= 10 SMALL EVERGREEN SHRUBS= 64
EXISTING UTILITY NOTE:THE LOCATION OF EXISTING UNDERGROUND UTILITIES ARESHOWN IN AN APPROXIMATE WAY ONLY AND HAVE NOT BEENINDEPENDENTLY VERIFIED BY THE OWNER OR ITSREPRESENTATIVE. THE CONTRACTOR SHALL DETERMINE THEEXACT LOCATION OF ALL EXISTING UTILITIES BEFORECOMMENCING ANY WORK, AND AGREES TO BE FULLYRESPONSIBLE FOR ANY AND ALL DAMAGES WHICH MIGHTOCCUR DUE TO THE CONTRACTOR'S FAILURE TO EXACTLYLOCATE AND PRESERVE ANY AND ALL UNDERGROUND UTILITIES.
NOTES:1.APPLY 6' DIAMETER MULCH RING TO ALL TREES IN TURF AREAS.2.SOD/SEED ALL DISTURBED AREAS NOT COVERED BY MULCH,VEGETATION, OR HARDSCAPE. DO NOT LEAVE BARE SOILEXPOSED.3.NO IRRIGATION COMPONENTS, INCLUDING BUT NOT LIMITED TO,VALVE BOXES, CONTROL BOXES, BACKFLOW PREVENTERS,AND/OR RAIN SENSORS ARE ALLOWED TO BE INSTALLED WITHINDEPARTMENT OF TRANSPORTATION RIGHT-OF-WAY.4.PLANT QUANTITIES IN PLANT SCHEDULE REPRESENT TOTALREQUIRED PLANT MATERIAL BASED ON CITY OF GREER CODE OFORDINANCES5.ALL DISTURBED OPEN SPACE TO BE STABILIZED WITH SEED / SOD
COPYRIGHT c SEAMON, WHITESIDE & ASSOCIATES, INC.THIS DRAWING SHALL NOT BE REPRODUCED IN ANY MANNER OR USED FOR ANY PURPOSE WITHOUT WRITTEN PERMISSION.
GR4714DBLM/CS10/14/22DATE:
501 WANDO PARK BOULEVARD, SUITE 200 | MOUNT PLEASANT, SC 29464 | 508 RHETT STREET, SUITE 101 | GREENVILLE, SC 29601
500 W MAIN STCITY OF SPARTANBURG, SOUTH CAROLINACOKE FACILITYREDEVELOPMENT PHASE 1REVISION HISTORYDRAWN BY:CHECKED BY:SW+ PROJECT:
MOUNT PLEASANT, SC843.884.1667GREENVILLE, SC864.298.0534
WWW.SEAMONWHITESIDE.COMSUMMERVILLE, SC843.972.0710SPARTANBURG, SC864.272.1272CHARLOTTE, NC980.312.54506/1/23
PHASE LINE
IRRIGATION NOTE:ALL REQUIRED PLANTING AREAS SHALL BE MECHANICALLY IRRIGATED. THISSHALL INCLUDE ALL TREE ISLANDS AND ALL AREAS OF REQUIRED FRONTAGELANDSCAPING BETWEEN THE PARKING LOT AND PUBLIC STREETS.REQUIRED PLANTING AREAS ASSOCIATED WITH PARKING LOTS CONTAININGLESS THAN THIRTY (30) PARKING SPACES ARE NOT REQUIRED TO BEIRRIGATED. HOWEVER, AN EXTERIOR WATER SOURCE, SUCH AS A HOSE BIB,SHALL BE LOCATED WITHIN 100 FEET OF ALL REQUIRED PLANTING AREAS.
PHASE TWOPHASE ONE
PHASE TWOPHASE ONE
CANOPY TREESCODEQTYBOTANICAL / COMMON NAMESIZEHEIGHTSPREADSPACINGREMARKSAce abz12Acer x freemanii `Jeffersred` / Autumn Blaze® Freeman Maple2.5" CALAS SHOWNFWF, SP Mag5Magnolia grandiflora 'Bracken's Brown Beauty' / Brackens Brown Beauty Magnolia2.5" CALAS SHOWNTAXD7Taxodium distichum / Bald Cypress2.5" CALAS SHOWNFWF, SP ULMB13Ulmus parvifolia `Bosque` / Bosque Elm2.5" CALAS SHOWNFWF, SP UNDERSTORY TREESCODEQTYBOTANICAL / COMMON NAMESIZEHEIGHTSPREADSPACINGREMARKSCORF10Cornus florida / Eastern Dogwood1.5" CAL8'AS SHOWNFWF, SP EVERGREEN SHRUBSCODEQTYBOTANICAL / COMMON NAMESIZEHEIGHTSPREADSPACINGREMARKSDis mnv100Distylium x 'PIIDIST-V' / First Editions® Cinnamon Girl® Distylium3 GAL Ile sha20Ilex glabra 'Shamrock' / Shamrock Inkberry Holly3 GAL ILVN87Ilex vomitoria `Nana` / Dwarf Yaupon3 GALAS SHOWNFWF, SP Vib mis66Viburnum obovatum `Mrs. Schiller`s Delight` / Mrs. Schillers Delight Walter`s Viburnum3 GALAS SHOWNFWF, SP GROUND COVERSCODEQTYBOTANICAL / COMMON NAMESIZEHEIGHTSPREADSPACINGREMARKSHem hap273Hemerocallis x 'Happy Returns' / Happy Returns DaylilyN/A LMBB722Liriope muscari `Big Blue` / Big Blue Lilyturf4" POT8"-12"8"-12"24"FWF, SP SOD/SEEDCODEQTYBOTANICAL / COMMON NAMESIZEHEIGHTSPREADSPACINGREMARKSSOD216,227 sfCynodon dactylon `TifTuf` / TifTuf Bermuda GrassSODN/AN/AN/ASP SEED16,227 sfCynodon dactylon / Bermuda GrassSEEDN/AN/AN/ASP
PLANT_SCHEDULE
L2.0PLANTSCHEDULEAND DETAILS 02/16/23B D03/27/23 F04/12/23 05/17/23IJ06/02/23
5
TYPICAL TREE PLANTING
LANDSCAPE NOTES
LAWN EDGE DETAIL
FROM CONTAINER STOCK
BED AREA.OF 8" IN ENTIRE SHRUBAMENDMENTS TO DEPTHPLANTING SOIL MIXTURETHOROUGHLY TILL INSHRUB PIT
MIXTURE TAMPED FIRMBENEATH ROOT BALL
FINISHED GRADE
45° MIN. 6" DEPTH PLANTING SOIL3X BALL DIA.
3" DEPTH MULCH
PULL ROOTS OUT OF BALLMINIMUM 4' DIAMETER.SHRUBS IN LAWNMULCH RING FOR
BASE OF PLANT MIN. 4")(KEEP MULCH AWAY FROM3" DEPTH MULCH
REMOVE TOP 1/3 BURLAPFROM B&B STOCKGENERAL NOTES:1. PLANT SO THAT TOP OF ROOT BALL IS 1" ABOVE FINISH GRADE.2. SCARIFY SIDES AND BOTTOM OF PIT.3. BACKFILL SHRUB PIT WITH SPECIFIED PLANTING SOIL MIXTURE IN 6" LAYERS, HAND-TAMPED, TO REMOVE VOIDS.4. WHEN 2/3 BACKFILLED, FILL WITH WATER.5. AFTER PLACING AND HAND-TAMPING FINAL LAYERS, WATER AGAIN UNTIL NO MORE WATER IS ABSORBED.TYPICAL SHRUB PLANTING
FINISH GRADEMIXTUREPLANTING SOIL45° MIN.3" DEPTH MULCH
GROUNDCOVER PLANT (TYP.)SPACING AS SHOWN ON PLANGROUNDCOVER PLANT
GENERAL NOTES:1. THOROUGHLY TILL IN PLANTING SOIL MIXTURE AMENDMENTS TO DEPTH OF 8" IN ENTIRE GROUNDCOVER BED AREA.2. WORK SOIL TO LOOSE, UNIFORMLY FINE TEXTURE.3. HAND-TAMP BACKFILL TO REMOVE VOIDS AND AIR POCKETS.4. WATER IMMEDIATELY AFTER PLANTING UNTIL NO MORE WATER IS ABSORBED.
SOIL NOTES
ABBREVIATIONS:FWF = FULL WELL FORMEDGAL = GALLON CONTAINERCON = CONTAINERIZED MATERIALMS = MULTI-STEMMED TRUNKCT = CLEAR TRUNKOC = ON-0CENTER FTG = FULL TO GROUNDTF = TREE FORM HABITTYP = TYPICALSP = SPECIMEN MATERIALCAL = TRUNK CALIPER (MIN) B&B = BALLED AND BURLAPPED
1.FOR EACH UNAMENDED SOIL TYPE, FURNISH SOIL ANALYSIS AND A WRITTEN REPORT BY A QUALIFIED SOIL-TESTINGLABORATORY STATING PERCENTAGES OF ORGANIC MATTER; GRADATION OF SAND, SILT, AND CLAY CONTENT; CATIONEXCHANGE CAPACITY; SODIUM ABSORPTION RATIO; DELETERIOUS MATERIAL; BUFFER PH LEVELS; AND MINERAL ANDPLANT-NUTRIENT CONTENT OF THE SOIL.2.A MINIMUM OF THREE REPRESENTATIVE SAMPLES SHALL BE TAKEN FROM VARIED LOCATIONS FOR EACH SOIL TO BE USEDOR AMENDED FOR PLANTING PURPOSES.3.SUBMIT TO LANDSCAPE ARCHITECT THE LAB RECOMMENDATIONS FOR SOIL TREATMENTS AND SOIL AMENDMENTS TO BEINCORPORATED. INDICATE LAB RECOMMENDATIONS IN WEIGHT PER 1000 SQ. FT. OR VOLUME PER CU. YD. FOR NITROGEN,PHOSPHORUS, AND POTASH NUTRIENTS AND ORGANIC AND INORGANIC SOIL AMENDMENTS TO BE ADDED TO PRODUCEPLANTING SOIL SUITABLE FOR HEALTHY, VIABLE PLANTS.4.ALL SOILS USED FOR PLANTING SHALL BE PREPARED AS NECESSARY USING ORGANIC AND INORGANIC SOIL AMENDMENTSAND FERTILIZERS IN THE QUANTITIES RECOMMENDED IN THE SOIL ANALYSIS REPORT TO PRODUCE SATISFACTORYPLANTING SOIL FOR HEALTHY, VIABLE PLANTS. PLANTING SOILS SHALL HAVE A PH LEVEL BETWEEN 6.0 AND 7.0.5.IN ALL PLANTING AREAS, SPREAD PLANTING SOIL TO A DEPTH OF 8 INCHES BUT NOT LESS THAN REQUIRED TO MEET FINISHGRADES AFTER NATURAL SETTLEMENT.
SUBGRADEMULCHAPPROX. 45 DEGREESAPPROX. 30 DEGREESTURFLC4"MIN.6"MAX.NOTES:1. EXCAVATE TRENCH BY HAND W/ SPADE2. ADD EXCESS SOIL TO ADJACENT PLANTBED AFTER PULLING BACK EXISTING MULCH.RAKE SOIL AND SMOOTH BEFORE MULCHING.
GRASS/GROUNDCOVER PLANTING
1.THE EXACT LOCATION OF ALL UNDERGROUND UTILITIES, EXISTING STRUCTURES, ETC. MAY NOT BE AS INDICATED ONDRAWINGS. FIELD LOCATE ALL UTILITIES, DRAINAGE STRUCTURES, LIGHT POLES, SIGNS, AND OTHER STRUCTURES PRIORTO INSTALLATION OF ANY PROPOSED IMPROVEMENTS CONTAINED WITHIN THE CONTRACT DOCUMENTS. NOTIFY THEOWNER'S REPRESENTATIVE IMMEDIATELY OF ANY POSSIBLE CONFLICTS BETWEEN PROPOSED IMPROVEMENTS ANDUTILITIES, SIGNS, AND/OR OTHER STRUCTURES.2.PRIOR TO PLANTING, A COLOR PHOTOGRAPH SUBMISSION FOR ALL PLANTS SPECIFIED SHALL BE SUBMITTED TO THELANDSCAPE ARCHITECT AND/OR OWNER'S REPRESENTATIVE FOR APPROVAL. EACH APPROVED PLANT PHOTOGRAPH SHALLBE THE MINIMUM STANDARD ACCEPTED FOR EACH PLANT SPECIES. THE PLANT PHOTOGRAPH SHALL SHOW THE ENTIREPLANT AND HAVE A LEGIBLE SCALE TO SHOW THE OVERALL HEIGHT AND SPREAD OF THE PLANT. PHOTOGRAPHS SHALLINDICATE THE GENUS, SPECIES, AND SIZE OF THE PLANT IN THE PHOTO.3.CONTRACTOR SHALL VERIFY ALL DIMENSIONS, ELEVATIONS AND UTILITY LOCATIONS PRIOR TO BEGINNING WORK.4.CONTRACTOR SHALL NOTIFY LANDSCAPE ARCHITECT OF ANY DISCREPANCIES PRIOR TO BEGINNING OR CONTINUING WORK.5.THERE WILL BE NO SUBSTITUTIONS, DELETIONS OR ADDITIONS WITHOUT APPROVAL OF THE LANDSCAPE ARCHITECT.6.SIZE OF PLANT MATERIALS SHALL CONFORM WITH THE CURRENT EDITION OF 'AMERICAN STANDARD FOR NURSERY STOCK'FOR NUMBER ONE GRADE NURSERY STOCK AS ADOPTED BY THE AMERICAN ASSOCIATION OF NURSERYMEN AND AMERICANNATIONAL STANDARDS INSTITUTE.7.ALL TREES SHALL HAVE A STRAIGHT, SINGLE LEADER UNLESS OTHERWISE NOTED.8.ALL PLANTS SHALL NOT DEMONSTRATE EVIDENCE OF PREVIOUS CONTAINER CONFINEMENT. ANY INDICATION OF ROOTDEVELOPMENT RESTRICTION, CIRCLING/GIRDLING ROOTS, OR EXCESSIVE ROOTS EXPOSED ABOVE THE SOIL SURFACESHALL BE GROUNDS FOR REJECTION.9.CONTRACTOR SHALL MEET WITH LANDSCAPE ARCHITECT PRIOR TO BEGINNING WORK SO THAT THERE IS A CLEARUNDERSTANDING OF PROJECT REQUIREMENTS. FAILURE TO DO SO JEOPARDIZES FINAL ACCEPTANCE OF WORK.10.ALL CONSTRUCTION SHALL CONFORM TO CITY, COUNTY, STATE AND FEDERAL REQUIREMENTS.11.LANDSCAPE ARCHITECT TO INSPECT QUALITY OF PLANT MATERIAL UPON ARRIVAL AT JOB SITE AND LAYOUT OF HARDSCAPEELEMENTS AND PLANT MATERIAL PRIOR TO INSTALLATION.12.DOUBLE SHREDDED HARDWOOD MULCH TO BE INSTALLED TO A MINIMUM 3" THICKNESS. APPLY 6' DIAMETER MULCH RINGTO ALL TREES IN TURF AREAS. MULCH ALL DISTURBED AREAS NOT COVERED BY PAVEMENT, TURF, OR OTHERVEGETATION.13.PROTECT EXISTING TREES TO REMAIN FROM DAMAGE.14.THIS PLAN IS SCHEMATIC AND, DUE TO THE NATURE OF CONSTRUCTION, SLIGHT FIELD MODIFICATIONS MAY BE NECESSARYTO IMPLEMENT THIS PLAN.
LANDSCAPE NOTES
1.CONTRACTOR TO INSTALL HIGH EFFICIENCY, FULLY CONTROLLED AUTOMATIC IRRIGATION SYSTEM WITH RAIN SENSOR PERIRRIGATION DRAWINGS AND SPECIFICATIONS AND PROVIDE SHOP DRAWINGS FOR LANDSCAPE ARCHITECT'S REVIEW.2.IT SHALL BE THE RESPONSIBILITY OF THE IRRIGATION CONTRACTOR TO MAKE SURE THAT ALL EQUIPMENT CONFORMS TOREQUIREMENTS OF ALL AUTHORITIES HAVING JURISDICTION AND MAKE ALL NECESSARY APPLICATIONS AND OBTAINAPPROVALS.3.DESIGN STATISTICS: 60 P.S.I. MAXIMUM. IF NEEDED DUE TO EXISTING LINE PRESSURE, INSTALL A REDUCTION VALVE. INADDITION, ZONES THAT OPERATE SPRAY SPRINKLERS AND MP ROTATOR SPRINKLERS SHOULD HAVE A PRESSUREREGULATING DEVICE ADDED TO THE ZONE CONTROL VALVE TO FURTHER REDUCE THE PRESSURE ON THESE ZONES TO35-40 P.S.I.4.ALL IRRIGATION HEADS THAT ARE LOCATED NEXT TO DRIVES AND ROADWAYS SHALL BE MOUNTED ON SWING JOINTS OR ON200 P.S.I. RATED FLEXIBLE PIPE. POSITION HEADS A MINIMUM 3" FROM CURB OR PAVEMENT.5.ADJUST ALL HEADS FOR COMPLETE COVERAGE WITH MINIMUM OVERSPRAY BEYOND LANDSCAPE AREAS.6.WHERE NOT OTHERWISE INDICATED, HEADS IN LAWN AREAS SHALL BE 4" POP-UP AND SHRUB AND GROUNDCOVER AREASSHALL BE DRIP IRRIGATED.7.SYSTEM PIPE SHALL BE CLASS 160 P.V.C. SIZE OF MAIN PIPE IS AS NOTED ON PLANS. SIZE ALL OTHER PIPE AS FOLLOWS:0-17 G.P.M.: 1"18-28 G.P.M.: 1-1/4"29-35 G.P.M.: 1-1/2"36-62 G.P.M.: 2"63+ G.P.M.: 2-1/2"8.WHERE POSSIBLE, COMBINE MAIN AND LATERAL PIPES IN SAME TRENCH.9.ALL CONTROL WIRES SHALL BE 14 GAUGE.10.CONTROLLER LOCATION AND MOUNTING TO BE APPROVED BY LANDSCAPE ARCHITECT. WHEN USED AS A MOUNT FOR THECONTROL PANEL AND OTHER DEVICES, ALL LUMBER SHALL BE PRESSURE TREATED FOR GROUND CONTACT USE. ALLHARDWARE AND FASTENERS SHALL BE GALVANIZED.11.WHEN A MUNICIPAL WATER SUPPLY IS USED FOR IRRIGATION, WATER METER AND CONNECTION TO MAIN SHALL BEPROVIDED BY PERTINENT WATER AUTHORITY. CONTRACTOR SHALL BEGIN HIS WORK AT THE METER. OWNER WILL ASSUMETHE COST OF THE TAP TO MUNICIPAL WATER SUPPLY AND IS RESPONSIBLE FOR COORDINATING THE INSTALLATION OF THEMETER.12.IF SYSTEM IS CONNECTED TO POTABLE WATER SUPPLY, PROVIDE BACKFLOW PREVENTION DEVICE IN ACCORDANCE WITHREQUIREMENTS OF ALL AUTHORITIES HAVING JURISDICTION. IF INSTALLED ABOVE GROUND, LOCATION OF DEVICE SHALLBE INCONSPICUOUS AND DEVICE SHALL BE PAINTED 'FLAT BLACK'.13.PROTECT EXISTING TREES TO REMAIN FROM DAMAGE. NOT MACHINE TRENCHING IS ALLOWED WITHIN THE DRIP LINE OFANY TREE. WHERE PIPING IS REQUIRED WITHIN THE DRIP LINE, POSITION PIPES TO MINIMIZE DISTURBANCE OF ROOTS ANDPERFORM ALL EXCAVATION BY HAND. DO NOT CUT ANY ROOTS LARGER THAN 34" DIAMETER.14.IRRIGATION PIPING, SPRINKLERS, AND OTHER EQUIPMENT MAY BE SHOWN OUTSIDE OF LANDSCAPE AREAS ON DRAWINGFOR GRAPHIC CLARITY. ALL VALVE BOXES AND EQUIPMENT VAULTS SHALL BE LOCATED IN MULCH BEDS.15.NO IRRIGATION COMPONENTS, INCLUDING BUT NOT LIMITED TO, VALVE BOXES, CONTROL BOXES, BACKFLOW PREVENTERS,AND/OR RAIN SENSORS ARE ALLOWED TO BE INSTALLED WITHIN DEPARTMENT OF TRANSPORTATION RIGHT-OF-WAY.
IRRIGATION PERFORMANCE SPECIFICATIONS
2016-01-25 WDM
TOP OF ROOT BALLSHALL BE FLUSH WITHFINISHED GRADE.TRUNK CALIPER SHALLMEET ANSI Z60 CURRENTEDITION FOR ROOT BALL SIZE.ROOT BALL WITH TRUNKFLARE VISIBLE.
EXISTING SOIL.SLOPE SIDES OFLOOSENED SOIL.
PRIOR TO MULCHING,LIGHTLY TAMP SOIL AROUNDTHE ROOT BALL IN 6" LIFTSTO BRACE TREE. DO NOTOVER COMPACT. WHEN THEPLANTING HOLE HAS BEENBACKFILLED, POUR WATERAROUND THE ROOT BALL TOSETTLE THE SOIL.3" LAYER OF MULCH.NO MORE THAN 1" OFMULCH ON TOP OF ROOTBALL. (SEE SPECIFICATIONSFOR MULCH).BOTTOM OF ROOT BALLRESTS ON EXISTING OR RECOMPACTED SOIL.
SINGLE CENTRAL LEADER
ROUND-TOPPED SOIL BERM 4" HIGH X 8" WIDEABOVE ROOT BALL SURFACESHALL BE CONSTRUCTED AROUNDTHE ROOT BALL. BERM SHALLBEGIN AT ROOT BALL PERIPHERY.FINISHED GRADE.
3X WIDEST DIMENSION OF ROOT BALL.
URBAN TREE FOUNDATION
© 2014OPEN SOURCE FREE TO USE
LOOSENED SOIL. DIG ANDTURN THE SOIL TO REDUCECOMPACTION TO THEAREA AND DEPTH SHOWN.
1
2
3
4
NOTE: ALL TREES TO BE PLANTED MIN. 5' FROM ANY PAVED SURFACE, INCLUDING CURB, SIDEWALK,AND ASPHALT UNLESS OTHERWISE NOTED ON THE PLANS. FAILURE TO FOLLOW THIS REQUIREMENT WILL RESULT IN REJECTION OF THE LOCATION DURING THE PUNCHLIST.
R
Know what'sbelow.before you dig.Call
COPYRIGHT c SEAMON, WHITESIDE & ASSOCIATES, INC.THIS DRAWING SHALL NOT BE REPRODUCED IN ANY MANNER OR USED FOR ANY PURPOSE WITHOUT WRITTEN PERMISSION.
GR4714DBLM/CS10/14/22DATE:
501 WANDO PARK BOULEVARD, SUITE 200 | MOUNT PLEASANT, SC 29464 | 508 RHETT STREET, SUITE 101 | GREENVILLE, SC 29601
500 W MAIN STCITY OF SPARTANBURG, SOUTH CAROLINACOKE FACILITYREDEVELOPMENT PHASE 1REVISION HISTORYDRAWN BY:CHECKED BY:SW+ PROJECT:
MOUNT PLEASANT, SC843.884.1667GREENVILLE, SC864.298.0534
WWW.SEAMONWHITESIDE.COMSUMMERVILLE, SC843.972.0710SPARTANBURG, SC864.272.1272CHARLOTTE, NC980.312.54506/1/23
Source: City of Spartanburg website. First collected Nov 8, 2026.