RecordWell Data

Design Review Board Meeting — Agenda Packet

Town of Hilton Head Island · Beaufort County · Design Review Board · meeting of Oct 22, 2024 · Agenda packets

Open the original document More from Town of Hilton Head Island

Text

Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.

Town of Hilton Head Island Design Review Board Meeting Tuesday, October 22, 2024, 2:30 PM 1 Town Center Court, Hilton Head Island, SC Conference Room #4 1. Call to Order 2. Adoption of the Agenda 3. Approval of the Minutes a. Regular Meeting Minutes of October 8th, 2024. 4. Unfinished Business 5. New Business a. DRB-001353-2024 - 2 North Forest Beach Drive - Flatbread Grill - Roof addition 6. Public Comment - Non Agenda Items 7. Board Business 8. Staff Reports 9. Adjournment FOIA Compliance: Public notification of this meeting has been published, posted, and distributed in compliance with the South Carolina Freedom of Information Act and the requirements of the Town of Hilton Head Island. In accordance with the requirements of Title II of the Americans with Disabilities Act of 1990 ("ADA"), the Town of Hilton Head Island will not discriminate against qualified individuals with disabilities on the basis of disability in its services, programs, or activities. Auditory accommodations are available. Any person requiring further accommodation should contact the Town of Hilton Head Island ADA Coordinator as Page 1 of 64 soon as possible but no later than 48 hours before the scheduled event. Municipal Association of South Carolina (MASC) Civility Pledge: “I pledge to build a stronger and more prosperous community by advocating for civil engagement, respecting others and their viewpoints, and finding solutions for the betterment of my city or town.” Page 2 of 64 Town of Hilton Head Island Design Review Board Meeting Minutes 10/8/2024 Page | 1 Town of Hilton Head Island DESIGN REVIEW BOARD MEETING Tuesday, October 8, 2024, 2:30 PM Minutes 1. Call to Order Chair Carstens called the meeting to order at 2:31 PM. 2. Adoption of the Agenda Mr. Parker made a motion to adopt the agenda as presented. The motion was seconded by Vice-Chair Lippert. 3. Approval of the Minutes a. Regular Meeting Minutes of September 24th, 2024. Vice-Chair Lippert made a motion to approve the minutes of September 24th, 2024. The motion was seconded by Ms. Pastor. 4. Unfinished Business None 5. New Business a. DRB-001286-2024 - 2 Park Lane - Sign Melissa Paul-Leto, Principal Planner of Design, presented the application for two new signs that would replace two older signs located at 2 Park Lane. Staff recommended approval with the following conditions: provide photos of existing signage as well as show exterior lighting and landscaping around the signage. The applicant, Shawn Congleton of Sign Design, explained that the complex is under new ownership and the current owner is looking to update the signs to provide a more modern feel and look. There was discussion among the board regarding color palette as the proposed image displayed colors that do not coincide with what is stated in the Design Guide. The board members also went into a hefty discussion regarding the dimensions of the proposed signs, ultimately suggesting that with the larger size of Sign A, Sign B should be smaller than what is currently being shown. Vice-Chair Lippert referenced Park Plaza, which she stated is a "much larger complex" with only one sign. Staff will verify whether the proposed signs are in compliance with buffers and max allowable sign quantity for the site and building size. With certain critical elements unclear at this stage, Chair Carstens suggested to the Page 3 of 64 Town of Hilton Head Island Design Review Board Meeting Minutes 10/8/2024 Page | 2 applicant that this item be tabled so that he could return at his next available opportunity with the necessary requests from the board. The applicant agreed to table the item and return at the October 22nd, 2024 meeting. b. DRB-001328-2024 - Coligny Circle Pocket Park - Conceptual Mr. Theodore recused himself. Melissa Paul Leto, Principal Planner of Design, presented the application for the Coligny Circle Pocket Park intended to be a civic gathering space that will also allow for pedestrian connectivity between Pope Avenue and North Forest Beach as well as a multi- use path to the adjacent commercial center. Staff recommended approval with the following conditions: screening utilities, providing lighting plans as well as existing and proposed landscape plans, and approval letter from the Forest Beach HOA. The board initially touched on landscaping and trees before going into discussion regarding furnishings. The applicant provided details and explained the furnishings would be fixed, which was a concern of the board with the consideration of hurricane season. Vice-Chair Lippert suggested that the trash receptacles be a bit closer to the bike racks for pedestrian convenience to avoid a litter issue. Ms. Pastor also suggested that the addition of pet waste receptacles be studied. Chair Carstens had some additional questions regarding landscaping and hose bibs. He then suggested there be additional plantings in the far corner of the park next to the neighboring coffee shop. Chair Carstens also inquired about the Coligny sign that currently resides in the proposed park space to which the applicant explained that they are working with the Town to come to a decision on potential removal or replacement. Vice-Chair Lippert made a motion to approve with the following conditions: staff comments be addressed, verify screening of transformers, review table selections, study trash bin locations, downplay coffee shop access, study wall caps, clarify plans for monument sign, and consider adding pet waste elements. The motion was seconded by Mr. Parker and passed with a note of 5-0-0. c. DRB-001329-2024 - 59 Pope Avenue - Pavillian at The Bank - Conceptual Mr. Theodore returned to the Dias. Chair Carstens recused himself and passed the gavel to Vice-Chair Lippert. Melissa Paul-Leto, Principal Planner of Design, presented the application for 59 Pope Avenue. The narrative of the application is the request for an open-air Pavilion located at 59 Pope Avenue, an existing restaurant called "The Bank." The proposed Pavilion is intended to be a 10-sided structure surrounding an existing fully designed space on the property. Staff recommended approval with the following conditions: provision of elevations, renderings of landscaping for subject areas, 11x17 material and color board, screening of utilities on site, as well as lighting and landscape plans. The applicant, Billy Watterson, owner of The Bank, provided additional comments regarding the structural intent. Page 4 of 64 Town of Hilton Head Island Design Review Board Meeting Minutes 10/8/2024 Page | 3 The board discussed the color selection to which the applicant provided clarification stating that his selection of "Charleston Green" matches the current entry point, and he believes it will also blend nicely with the natural landscape. Mr. Parker inquired about the inspiration behind the selection of wood for the posts to which the application replied that the trellises are composed of the same material. Ms. Pastor inquired about the potential addition of fans in the pavilion. The applicant clarified that the two-layer roof is intended to encourage airflow throughout the space. Vice-Chair Lippert suggested that the applicant include the large screen adjacent to the Pavilion in their elevations at the final review stage for reference and context purposes solely. Mr. Parker suggested the screen be noted in the final renderings as "not being reviewed" for clarification. Mr. Parker made a motion to approve with the following conditions: staff comments be addressed, include bar and screen in renderings, and the colors match the existing entry point. The motion was seconded by Ms. Fitzpatrick and passed with a vote of 5-0-0. 6. Public Comment - Non Agenda Items Chair Carstens returned to the Dias and Vice-Chair Lippert passed the gavel back. There was no public comment. 7. Board Business Vice-Chair Lippert inquired about voting parameters which Staff addressed and is hoping to have clear direction for the board on a number of items at the next meeting. The board also asked about the possibility of a collaborative Design Guide rewrite and is awaiting an LMO timeline update from Ms. Paul-Leto. 8. Staff Reports Melissa Paul-Leto gave various Minor Corridor Reports. 9. Adjournment The meeting was declared adjourned at 4:11 PM. The recording of this Meeting can be found on the Town’s website at www.hiltonheadislandsc.gov Page 5 of 64 Page 6 of 64 Last Revised 01/21/15 1 Applicant/Agent Name: ______________________________ Company: _____________________________________ Mailing Address: ___________________________________ City: _________________ State: ______ Zip: ________ Telephone: ___________________ Fax: _________________ E-mail: _______________________________________ Project Name: _________________________________ Project Address: _____________________________________ Parcel Number [PIN]: R__ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ Zoning District: _______________________________ Overlay District(s): ___________________________________ Town of Hilton Head IslandCommunity Development DepartmentOne Town Center Court Hilton Head Island, SC 29928 Phone: 843-341-4757 Fax: 843-842-8908 www.hiltonheadislandsc.gov CORRIDOR REVIEW, MAJORDESIGN REVIEW BOARD (DRB) SUBMITTAL REQUIREMENTSDigital Submissions may be accepted via e-mail by calling 843-341-4757.Project Category:_____ Concept Approval – Proposed Development _____ Alteration/Addition_____ Final Approval – Proposed Development _____ Sign FOR OFFICIAL USE ONLYDate Received: _____________ Accepted by:______________DRB #:___________________Meeting Date:_____________ Submittal Requirements for All projects:_____ Private Architectural Review Board (ARB) Notice of Action (if applicable): When a project is within the jurisdiction of an ARB, the applicant shall submit such ARB’s written notice of action per LMO Section 16-2-103.I.4.b.iii.01. Submitting an application to the ARB to meet this requirement is the responsibility of the applicant. _____ Filing Fee: Concept Approval-Proposed Development $175, Final Approval – Proposed Development $175, Alterations/Additions $100, Signs $25; cash or check made payable to the Town of Hilton Head Island.Additional Submittal Requirements:Concept Approval – Proposed Development_____A survey (1"=30' minimum scale) of property lines, existing topography and the location of trees meeting the tree protection regulations of Sec. 16-6-104.C.2, and if applicable, location of bordering streets, marshes and beaches. _____ A site analysis study to include specimen trees, access, significant topography, wetlands, buffers, setbacks, views, orientation and other site features that may influence design. _____ A draft written narrative describing the design intent of the project, its goals and objectives and how it reflects the site analysis results. _____ Context photographs of neighboring uses and architectural styles. _____ Conceptual site plan (to scale) showing proposed location of new structures, parking areas and landscaping. _____ Conceptual sketches of primary exterior elevations showing architectural character of the proposed development, materials, colors, shadow lines and landscaping. DePauw ArchitectsJoe DePauwPO Box 688BlufftonSC29910(843) 284-7848joe@depauw.studioImprovements to Flatbread Grill2 N Forest Beach Dr., #101CR (Coligny Resort)Corridor OverlayX Page 7 of 64 Last Revised 01/21/15 2Note: All application items must be received by the deadline date in order to be reviewed by the DRB per LMO Appendix D: D-23.A representative for each agenda item is strongly encouraged to attend the meeting.Are there recorded private covenants and/or restrictions that are contrary to, conflict with, or prohibit the proposed request? If yes, a copy of the private covenants and/or restrictions must be submitted with this application. YES NOTo the best of my knowledge, the information on this application and all additional documentation is true, factual, and complete. I hereby agree to abide by all conditions of any approvals granted by the Town of Hilton Head Island. I understand that such conditions shall apply to the subject property only and are a right or obligation transferable by sale.I further understand that in the event of a State of Emergency due to a Disaster, the review and approval times set forth in the Land Management Ordinance may be suspended. SIGNATURE DATE Additional Submittal Requirements:Final Approval – Proposed Development_____ A final written narrative describing how the project conforms with the conceptual approval and design review guidelines of Sec. 16-3-106.F.3._____ Final site development plan meeting the requirements of Appendix D: D-6.F. _____ Final site lighting and landscaping plans meeting the requirements of Appendix D: D-6.H and D-6.I._____ Final floor plans and elevation drawings (1/8"=1'-0" minimum scale) showing exterior building materials and colors with architectural sections and details to adequately describe the project. _____ A color board (11"x17" maximum) containing actual color samples of all exterior finishes, keyed to the elevations, and indicating the manufacturer's name and color designation. _____ Any additional information requested by the Design Review Board at the time of concept approval, such as scale model or color renderings, that the Board finds necessary in order to act on a final application. Additional Submittal Requirements:Alterations/Additions _____ All of the materials required for final approval of proposed development as listed above, plus the following additional materials._____A survey (1"=30' minimum scale) of property lines, existing topography and the location of trees meeting the tree protection regulations of Sec. 16-6-104.C.2, and if applicable, location of bordering streets, marshes and beaches._____ Photographs of existing structure. Additional Submittal Requirements:Signs _____ Accurate color rendering of sign showing dimensions, type of lettering, materials and actual color samples.For freestanding signs:_____ Site plan (1”=30’ minimum scale) showing location of sign in relation to buildings, parking, existing signs, and property lines. _____ Proposed landscaping plan. For wall signs:_____ Photograph or drawing of the building depicting the proposed location of the sign. _____ Location, fixture type, and wattage of any proposed lighting. **All colors match existing 9/30/2024 Page 8 of 64 Page 9 of 64 May 15, 2024 Town of Hilton Head Island One Town Center Court Hilton Head Island, SC 29928 Re: DRB Alteration/Addition Review Improvements to Flatbread Grill & Bar 2 North Forest Beach Drive, #101 Hilton Head Island, SC 29928 R552 018 000 0012 0000 To whom it may concern, In support of our DRB Review Submission, please find the attached plan set, application, lighting cut-sheets and Forest Beach Owner’s Association approval. Our Project Narrative follows below. Should you require additional information ahead of our meeting, please let me know. Scope of the Project: The project proposes to add a roof over the uncovered dining terraces surrounding the Flatbread Grill to the northwest and southwest. The roof will be low sloped and wrap around the existing porch gable at the top of the stairs from the parking lot. The gable and signage will remain as a prominent architectural element signifying the entry and to break up the massing of the western facade. The new roofing will be standing seam metal to match the existing roof and the appearance of the improvements have been developed to relate to the existing structure and courtyard trellis. The existing deck structure & railings will remain as structurally feasible. If the existing posts are not capable of carrying the additional loads, the decking will be temporarily supported while new taller posts (and new footings if required) are installed. The deck structure will then be re- attached to the columns. Building Areas: The development consist of three (3) existing, raised one-story buildings with a combined conditioned area of approximately 15,750 sq. ft. (12,910 sq. ft. + 2,360 sq. ft. + 480 sq. ft.). This project will not change the number of structures, conditioned square footage, or the amount of outdoor dining area. Maintenance Responsibility: Maintenance of the new roof structure will be by the owners of the Flatbread Grill. Page 10 of 64 Tree Removal & Mitigation: The existing deck structure was constructed around a 14” Live Oak. We propose to remove the tree with the new roof addition. Two new Live Oak trees meeting the requirements of LMO 16- 6-104.I.3 will be located on-site where indicated on the site plan. Setbacks & Buffers: The property is zoned Coligny Resort and is separated from the edge of the zone by a ToHHI owned park parcel. As a result, there is not an Adjacent Use setback along the west property line. Per LMO Sec. 16-3-105.B.3, Adjacent Use Setback Requirements “shall apply only along the perimeter of the CR district.” There is not an Adjacent Street setback as the west property line does not adjoin a street. No Adjacent Use Buffers are required between Commercial Services & Public Use along the west property line. The property lines from the North & South edges of the property do not effect the project. Site Coverage: This project will not change the impervious coverage on the site. Utilities: The project will rely on existing service to the restaurant for electrical needs. Plumbing and mechanical service are not required by the improvements. Grading: The raised nature of the structure will be maintained, and the existing grading will remain. Page 11 of 64 In addition, we are providing the following notes on the staff comments provided during pre- application review: Development Review 1. This project requires a Major Development Plan Review (DPR) application. Submit all of the applicable materials listed in LMO Appendix D-6. a. The Major DPR application is attached. 2. Show all building and site improvements on the plan, including HVAC units, utility equipment and pedestals, and stairs. a. All improvements are shown on the plans. There are no new HVAC units, utility equipment, pedestals or stairs proposed. 3. This project requires a Major Corridor Review application. Submit all of the applicable materials listed in LMO Appendix D-9. a. This application will be submitted separately to the DRB. 4. Provide encroachment permits or approvals from all applicable outside agencies such as DHEC, OCRM, PSD, Hargray, Palmetto Electric, any applicable private ARB, SCDOT, Beaufort County, etc. a. No encroachments are anticipated to be required. Private ARB approval from the Forest Beach Owner’s Association is attached. 5. Provide a table on the plans with the following information for your project: a. Please find this table at the bottom left of sheet AS101 Site Development Plan. 6. If the proposed project is to be constructed in phases, provide a phasing plan indicating what is to be completed in each phase of the project. a. This project will not be phased. 7. LMO Section 16-5-102.C. – North Forest Beach Drive, from Coligny Circle to Avocet St., is classified as a Minor Arterial with an adjacent street setback of 30 feet. Please delineate all setbacks on plans. a. Please refer to sheet AS101 Site Development Plan. The setback does not effect the proposed scope of work area. 8. LMO Section 16-5-108 – Provide a site lighting plan for any new site lighting proposed. a. No new site lighting is proposed. Stormwater Engineering 9. Please have applicant review and complete a Stormwater Erosion Control Affidavit. a. The completed Stormwater Erosion Control Affidavit is attached. Natural Resources 10. The 14" Live Oak proposed for removal will require mitigation. Provide a landscaping plan that shows tree mitigation at the rate of (1) tree for every 10” being removed, by category. a. Two (2) new Live Oak trees meeting the requirements of LMO 16-6-104.I.3 will be located on-site where indicated on sheet AS101 Site Development Plan. Page 12 of 64 11. Tree Protection Zones Sec. 16-6-104 - Tree protection zones for any trees located within 25' of any proposed grading, construction, or tree removals; to be established by physical barriers that will need to be maintained until such time that the work is completed. SPECIAL ATTENTION must be shown for the Specimen tree protection areas that prevent paving or soil compaction within 15' of the trunk. These Specimen tree protection zones should be substantial, such as cyclone or wooden fencing that will prevent access to these 15' areas or material storage of any kind. a. Tree protection will be provided for trees within 25 feet of the construction. No specimen trees are within this area. 12. Tree Protection/Preservation, Sec. 16-6-104.B.1.a - All persons are required to make all reasonable efforts to preserve and retain any existing stands of trees, individual trees, and other self-supporting plants, whether or not such plants are protected under this section, as well as such other flora that make up part of the understory, shrub layer, or herb layer. a. Minimal understory, shrub layer or herb layer exist in the proposed scope of work area. Urban Design Review 13. This project requires review/approval from the Town’s Design Review Board under a Major Corridor Review submittal. Major Corridor reviews are a design review consisting of two reviews by the Board. The first is a Conceptual Review for direction and feedback from the Board. The second review is considered the Final Review and should consist of a complete design set with appropriate material and color boards. Please see application and checklist for more information. The application form can be found here: https://hiltonheadislandsc.gov/forms/bldgdev/DesignReviewApp.pdf You can also contact Alexis McIlwee at 843-341-4676 or alexism@hiltonheadislandsc.gov for more information. a. This application will be submitted separately to the DRB. Thank you for your time and consideration, Joseph DePauw, AIA Principal DePauw Architects Page 13 of 64 Page 14 of 64 Page 15 of 64 Page 16 of 64 FOREST BEACH OWNERS’ ASSOCIATION, INC. P O Box 6442 Hilton Head Island, SC 29938-6442 (843)785-5565 FAX (843) 342-3801 Email: FBAssn@gmail.com September 23, 2024 Allstar, LLC Re: 2 NFB DR – Exterior Attn: Mr. Alan Mintz & Mr. Amir Bitton Renovations & Additions 2 North Forest Beach DR #101 CFB Hilton Head Island, SC 29928 Permit Number 2024-082101 Dear: Mr. Mintz & Bitton: Thank you for your submission for architectural review for roof covering for your existing outdoor dining terraces. We have reviewed your request for construction at the above location. This review and approval is based upon the following: 1) Our review is based upon the documents, drawings and narratives submitted to us. Application dated, August 21, 2024 and drawings dated August 13, 2024 along with your plan narrative and renderings 2) Building setbacks from property are per LMO. 3) Tree removal based upon the site plan is approved, subject to the required approval and mitigation by the Town of Hilton Head Island. 4) No construction, vertical, subterranean or otherwise, may be placed within any building setback or buffer. This includes, but is not limited to, the following: Service yards, HVAC equipment, above ground LPG storage tanks, storage yards, refuse receptacles, satellite dish/antenna, vehicle parking, decking or patios, hardscape materials or material of a non-pervious nature (e.g. cement walkways or driveways). 5) No exterior lighting, other than that shown on the submitted plans, is approved. Any changes/additions/modifications to the submitted and approved plans will be required to be submitted to the FBOA ARB for review and approval before construction of the change/addition/modification is begun. Failure to do so may result in a covenant violation. Items not shown on the submitted plans are not reviewed or approved and must be submitted with the final plans to be reviewed for approval. Please make a note of any additional items that we require above. Failure to submit the requested documents for review prior to the start of construction may result in a covenant violation. Page 17 of 64 We must be notified, in writing, upon completion of the project. Assuming no discrepancies between the approved work and the inspected, finished project, we will conduct a final inspection and close our files on this project. We have emailed a copy of your approval to the Town and contractor for their records as well as enclosing your ARB Building Permit. We request that the permit be posted at the site during construction alongside the Town of Hilton Head Island Building Permit. Please provide a copy of this approval to your contractor upon selection and have posted on site during construction. Thank you for your submission, and, please do not hesitate to contact us with any questions. Sincerely, John D. Snodgrass John D. Snodgrass, Executive Director JDS:me Encl. Cc: Town of Hilton Head Island, PIC – Email Tony Genovese – Email DePauw Architects – Email Town of Hilton Head Island, Natural Resources - Email F750D0 Page 18 of 64 Page 19 of 64 Page 20 of 64 Page 21 of 64 Page 22 of 64 Page 23 of 64 Page 24 of 64 Page 25 of 64 Page 26 of 64 Page 27 of 64 Page 28 of 64 Page 29 of 64 Page 30 of 64 Page 31 of 64 Page 32 of 64 Page 33 of 64 Page 34 of 64 Page 35 of 64 Page 36 of 64 Page 37 of 64 Page 38 of 64 Page 39 of 64 Page 40 of 64 (843) 284-7848 www.depauw.studio PO BOX 688 BLUFFTON, SC 29910 SHEET PROJECT NO. REVISIONS © COPYRIGHT 2024 DePAUW ARCHITECTS LLC THIS DRAWING IS THE PROPERTY OF THE ARCHITECT AND IS NOT TO BE REPRODUCED IN WHOLE OR IN PART BY ANY MEANS OR METHOD WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ARCHITECT. ANY UNAUTHORIZED REPRODUCTION OR REUSE OF THESE DOCUMENTS WILL RESULT IN LEGAL ACTION. PROJECT CONTACT DATE NOT FOR CONSTRUCTION 2411 EXISTING CONDITIONS PHOTOS 9/30/24 AS102 FLATBREAD GRILL 2 N. FOREST BEACH DRIVE UNIT #101 HILTON HEAD ISLAND, SC 29928 ISSUED FOR REVIEW IMPROVEMENTS TO: JAD ID DESCRIPTION DATE Page 41 of 64 Page 42 of 64 ZONING TABLE: ZONING DISTRICT: OVERLAY DISTRICT: USE OF PROPERTY: GROSS SITE ACRES: NET SITE ACRES: (GROSS ACRES - TIDAL WETLANDS) DISTURBED ACREAGE: EXISTING BUILDING SQUARE FOOTAGE: PROPOSED BUILDING SQUARE FOOTAGE: EXISTING PARKING: TOTAL REQUIRED PARKING: TOTAL ADDITIONAL PARKING: EXPECTED NUMBER OF MONTHS TO COMPLETE PROJECT: COLIGNY RESORT DISTRICT CORRIDOR OVERLAY RESTAURANT & MIXED COMMERCIAL USES 0.93 ACRES 0.93 ACRES 0.02 AC. ±15,750 SQ. FT. ±15,750 SQ. FT. (NO NEW CONDITIONED AREA ADDED) 70 SPACES N/A (NO CHANGE IN OUTDOOR DINING AREA SIZE) 0 SPACES 3 MONTHS FLOOD ZONE: FIRM FLOOD ZONE: BASE FLOOD ELEVATION: DESIGN FLOOD ELEVATION: AO (DEPTH 1 FT.) & X N/A N/A SITE INFO: TAX MAP & PARCEL NUMBER: R552 018 000 0012 0000 LOT COVERAGE: EXISTING IMPERVIOUS AREA: PROPOSED IMPERVIOUS AREA: ±33,332 SQ. FT. ±33,332 SQ. FT. (NO CHANGE) SETBACK & BUFFER AREAS: DO NOT APPLY TO THE AREA OF PROPOSED CONSTRUCTION. (843) 284-7848 www.depauw.studio PO BOX 688 BLUFFTON, SC 29910 SHEET PROJECT NO. REVISIONS © COPYRIGHT 2024 DePAUW ARCHITECTS LLC THIS DRAWING IS THE PROPERTY OF THE ARCHITECT AND IS NOT TO BE REPRODUCED IN WHOLE OR IN PART BY ANY MEANS OR METHOD WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ARCHITECT. ANY UNAUTHORIZED REPRODUCTION OR REUSE OF THESE DOCUMENTS WILL RESULT IN LEGAL ACTION. PROJECT CONTACT DATE NOT FOR CONSTRUCTION 2411 COVER SHEET 9/30/24 A001 FLATBREAD GRILL 2 N. FOREST BEACH DRIVE UNIT #101 HILTON HEAD ISLAND, SC 29928 ISSUED FOR REVIEW FLATBREAD GRILL ISSUED FOR REVIEW IMPROVEMENTS TO: JAD 2 N. FOREST BEACH DRIVE, UNIT #101, HILTON HEAD ISLAND, SC 29928 DRAWING INDEX: SHEET # SHEET NAME A001 COVER SHEET __ PLAT AS101 SITE DEVELOPMENT PLAN AS102 EXISTING CONDITIONS PHOTOS AD101 DEMOLITION PLANS A102 FIRST FLOOR PLAN A103 ROOF PLAN A201 ELEVATIONS A202 ELEVATIONS A203 MASSING MODEL AE101 LIGHTING PLAN ABBREVIATIONS: AB ANCHOR BOLT ABV ABOVE AFF ABOVE FINISH FLOOR ASF ABOVE SUB-FLOOR A/C AIR CONDITIONER AHU AIR HANDLING UNIT ALUM ALUMINUM AMSL ABOVE MEAN SEA LEVEL APPROX APPROXIMATE BD BOARD BF BI-FOLD BLKG BLOCKING BLDG BUILDING B.O. BOTTOM OF BOD BASIS OF DESIGN BRG BEARING BTW BETWEEN CAB CABINET CANT CANTILEVER CEN CENTER CIP CAST-IN-PLACE CJ CEILING JOIST CL CENTERLINE CLOS CLOSET CLG CEILING CM CASEMENT CO CASED OPENING COL COLUMN CONC CONCRETE CT CERAMIC TILE DBL DOUBLE DEMO DEMOLISH DH DOUBLE HUNG DIA DIAMETER DIM DIMENSION DIST DISTANCE DN DOWN DR DOOR DW DISHWASHER DWG DRAWING EA EACH ELEV ELEVATION ELEC ELECTRICAL EQ EQUAL EQUIP EQUIPMENT EXST EXISTING EXT EXTERIOR FD FLOOR DRAIN FDN FOUNDATION FDTN FOUNDATION FF FINISH FLOOR FFE FINISH FLOOR ELEVATION FIN FINISH FIX FIXTURE FIXT FIXTURE FLUOR FLUORESCENT FLR FLOOR FRZ FREEZER FRMG FRAMING FT FEET FTG FOOTING GA GAUGE GALV GALVANIZE GL GLASS GYP GYPSUM GWB GYPSUM WALL BOARD HB HOSE BIBB HDR HEADER HORIZ HORIZONTAL HT HEIGHT I.D. INSIDE DIMENSION IN INCH INCL INCLUDE INSUL INSULATION INT INTERIOR JST JOIST JNT JOINT KS KNEE SPACE VICINITY MAP: PROJECT TEAM: DISCIPLINE NAME LICENSE: PHONE NO: ARCHITECT DePAUW ARCHITECTS 101932 (843) 284-7848 LANDSCAPE --- --- --- STRUCTURAL --- --- --- BUILDING CODES: (ALL CODES W/ SOUTH CAROLINA MODIFICATIONS) INTERNATIONAL BUILDING CODE: INTERNATIONAL FIRE CODE: INTERNATIONAL PLUMBING CODE: INTERNATIONAL MECHANCIAL CODE: INTERNATIONAL FUEL-GAS CODE: INTERNATIONAL EXISTING BUILDING CODE: INTERNATIONAL ENERGY CONSERVATION CODE: NATIONAL ELECTRICAL CODE: 2021 2021 2021 2021 2021 2021 2021 2020 (NFPA 70) DESCRIPTION OF WORK ADDITION OF A PORCH ROOF OVER AN EXISTING OPEN DECK. OCCUPANCY & CONSTRUCTION: OCCUPANCY CLASSIFICATION: OCCUPANT LOAD: CONSTRUCTION: SPRINKLERED/NON: (IBC §903) • ASSEMBLY (A-2) TYPE V-B (UNCHANGED) AUTO. SPRINKLER SYSTEM EXISTING DRY HEADS TO BE ADDED TO WET SYSTEM THROUGH EXTERIOR WALL OF RESTAURANT NOTES: NOTICE TO PERMITTING AUTHORITY & BUILDING OWNER REGARDING CONSTRUCTION ADMINISTRATION SERVICES: THE SEALING ARCHITECT AND THE FIRM OF RECORD HAVE NOT BEEN ENGAGED TO PERFORM THE MINIMUM CONSTRUCTION ADMINISTRATION SERVICES, AS DEFINED IN SC CODE OF REGULATIONS CHAPTER 11-12.B(5). ARCHITECT OF RECORD IS NOT RESPONSIBLE FOR INTERPRETING THE INTENT OF THE CONSTRUCTION DOCUMENTS INCLUDING MAKING MODIFICATIONS AS MAY BE NECESSARY DURING THE CONSTRUCTION PHASE; AND THE ARCHITECT OF RECORD IS NO LONGER LIABLE FOR THE WORK WHERE CHANGES TO THESE DOCUMENTS HAVE BEEN MADE. LAM LAMINATE LL LIVE LOAD LT LIGHT LIN LINEN MA MASONRY MAS MASONRY MAX MAXIMUM MECH MECHANICAL MED MEDIUM MFR MANUFACTURER MID MIDDLE MIN MINIMUM MISC MISCELLANEOUS MUL MULLION N/A NOT APPLICABLE N.I.C. NOT IN CONTRACT NTS NOT TO SCALE OC ON CENTER OD OUTSIDE DIMENSION OH OVERHANG OPNG OPENING OSB ORIENTED STRAND BOARD PAF POWER-ACTUATED FASTENER PDE POP-UP DRAIN EMITTER PEMB PRE-ENGINEERED METAL BLDG PL PLATE PNL PANEL PNT PAINT PMEJ PRE-MOULDED EXPANSION JOINT PR PAIR PT PRESSURE TREATED PVC POLYVINLYCHLORIDE PVMT PAVEMENT PLY PLYWOOD PWDR POWDER ROOM R RADIUS R & S ROD & SHELF RAG RETURN AIR GRILL REF REFRIGERATOR REQ'D REQUIRED RM ROOM RV RIDGE VENT SAF SELF-ADHERED FLASHING SCHED SCHEDULE SECT SECTION SF SQUARE FEET SH SHELF SIM SIMILAR SND SANITARY NAPKIN DISPENSER SPEC SPECIFICATION SF SQUARE FEET STD STANDARD STL STEEL STOR STORAGE SYS SYSTEM T TREAD T.O. TOP OF TR TREATED T & G TONGUE & GROOVE TEL TELEPHONE TEMP TEMPORARY/ TEMPERATURE THK THICK TV TELEVISION TPH TOILET PAPER HOLDER TYP TYPICAL UC UNDER-COUNTER UNFIN UNFINISHED U.N.O. UNLESS NOTED OTHERWISE U.O.N. UNLESS OTHERWISE NOTED VB VAPOR BARRIER VER VERIFY V.I.F. VERIFY IN FIELD VERT VERTICAL WD WOOD W/D WASHER-DRYER WH WATER HEATER CODE ANALYSIS: PROJECT SITE ID DESCRIPTION DATE Page 43 of 64 Page 44 of 64 DN EXISTING FLATBREAD GRILL RESTAURANT EXISTING FABRIC AWNING AREA EXISTINGBAR WINDOW EXISTING PORCH EXISTING TRELLIS AREA(APPROXIMATE) SCOPE OF WORK 25'-0" ADJACENT USE SETBACK (ALL OTHER RESIDENTIAL) 25'-0" ADJACENT USE SETBACK (ALL OTHER RESIDENTIAL) 30'-0"/60° ADJACENT STREET SETBACK (CR DISTRICT) NO SETBACKS NO BUFFERS 14" LO 7 5 2 1 4 8 9 3 APPROX. LOCATION OF 14" LIVE OAK TO BE REMOVED (MEASURED 5/15/24) AREA OF DECK TO BE ROOFED (544 SQ. FT.) (UNIT 101) UNIT 103 NOTE: EXISTING GRADING TO REMAIN SURROUNDING ALL PROPOSED IMPROVEMENTS ±470 SF ±2,360 SF ±12,910 SF (2) NEW LIVE OAKS (QUERCUS VIRGINIANA) 10' MIN. HT., 2" MIN. TRUNK DIAMETER @ TIME OF PLANTING TREE PROTECTION FOR TREES WITHIN 25' OF CONSTRUCTION, TYP. FIELD VERIFY LOCATIONS (SEE 2/AS101) ZONING TABLE: ZONING DISTRICT: OVERLAY DISTRICT: USE OF PROPERTY: GROSS SITE ACRES: NET SITE ACRES: (GROSS ACRES - TIDAL WETLANDS) DISTURBED ACREAGE: EXISTING BUILDING SQUARE FOOTAGE: PROPOSED BUILDING SQUARE FOOTAGE: EXISTING PARKING: TOTAL REQUIRED PARKING: TOTAL ADDITIONAL PARKING: EXPECTED NUMBER OF MONTHS TO COMPLETE PROJECT: COLIGNY RESORT DISTRICT CORRIDOR OVERLAY RESTAURANT & MIXED COMMERCIAL USES 0.93 ACRES 0.93 ACRES 0.02 AC. ±15,750 SQ. FT. ±15,750 SQ. FT. (NO NEW CONDITIONED AREA ADDED) 70 SPACES N/A (NO CHANGE IN OUTDOOR DINING AREA SIZE) 0 SPACES 3 MONTHS FLOOD ZONE: FIRM FLOOD ZONE: BASE FLOOD ELEVATION: DESIGN FLOOD ELEVATION: AO (DEPTH 1 FT.) & X N/A N/A SITE INFO: TAX MAP & PARCEL NUMBER: R552 018 000 0012 0000 LOT COVERAGE: EXISTING IMPERVIOUS AREA: PROPOSED IMPERVIOUS AREA: ±33,332 SQ. FT. ±33,332 SQ. FT. (NO CHANGE) SETBACK & BUFFER AREAS: DO NOT APPLY TO THE AREA OF PROPOSED CONSTRUCTION. TREES TO BE REMOVED CATEGORY 1 LIVE OAK 14" DBH INCHES 14" CATEGORY 2 DBH INCHES CATEGORY 3 DBH INCHES CATEGORY 4 DBH INCHES TOTAL # TREES: TOTAL DBH: TOTAL # TREES: TOTAL DBH: TOTAL # TREES: TOTAL DBH: TOTAL # TREES: TOTAL DBH: 1 14" REPLACEMENT TREES CATEGORY 1 LIVE OAK DBH INCHES 2" MIN. CATEGORY 2 DBH INCHES CATEGORY 3 DBH INCHES CATEGORY 4 DBH INCHES TOTAL # TREES: TOTAL DBH: TOTAL # TREES: TOTAL DBH: TOTAL # TREES: TOTAL DBH: TOTAL # TREES: TOTAL DBH: 2 4" MIN. LIVE OAK 2" MIN. 4'-0" ATTACH SIGN TO POST NOTES: 1. NO PRUNING SHALL BE PERFORMED EXCEPT BY APPROVED ARBORIST 2. NO EQUIPMENT SHALL OPERATE INSIDE THE PROTECTIVE FENCING INCLUDING DURING FENCE INSTALLATION AND REMOCAL. 3. NO MATERIAL TO BE STORED WITHIN THE TREE PROTECTION FENCE. 4. SEE SITE PLAN FOR LOCATION. 5. TREE PROTECTION FENCING SHALL BE MAINTAINED THROUGHOUT THE DURATION OF THE PROJECT. FENCE MUST REMAIN UPRIGHT AND SLACK FREE. 6. WARNING SIGNS ARE TO BE MADE OF DURABLE WATERPROOF MATERIAL. 24" x 24" MINIMUM SIZE AND VISIBLE FROM BOTH SIDES OF THE FENCE TREE PROTECTION FENCE: ORANGE UV RESISTANT HIGH-TENSILE STRENGTH POLYETHYLENE LAMINAR BARRICADE FABRIC 1.33 LBS/LF STEEL POST @ 6'-0" O.C. 6" THK. LAYER OF MULCH W/IN FENCE MAINTAIN EXISTING GRADE W/IN THE TREE PROTECTOIN FENCE U.N.O. (843) 284-7848 www.depauw.studio PO BOX 688 BLUFFTON, SC 29910 SHEET PROJECT NO. REVISIONS © COPYRIGHT 2024 DePAUW ARCHITECTS LLC THIS DRAWING IS THE PROPERTY OF THE ARCHITECT AND IS NOT TO BE REPRODUCED IN WHOLE OR IN PART BY ANY MEANS OR METHOD WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ARCHITECT. ANY UNAUTHORIZED REPRODUCTION OR REUSE OF THESE DOCUMENTS WILL RESULT IN LEGAL ACTION. PROJECT CONTACT DATE NOT FOR CONSTRUCTION 2411 SITE DEVELOPMENT PLAN 9/30/24 AS101 FLATBREAD GRILL 2 N. FOREST BEACH DRIVE UNIT #101 HILTON HEAD ISLAND, SC 29928 ISSUED FOR REVIEW IMPROVEMENTS TO: JAD 1/16" = 1'-0"AS101 1 SITE PLAN ID DESCRIPTION DATE 1/4" = 1'-0"AS101 2 TREE PROTECTION Page 45 of 64 (843) 284-7848 www.depauw.studio PO BOX 688 BLUFFTON, SC 29910 SHEET PROJECT NO. REVISIONS © COPYRIGHT 2024 DePAUW ARCHITECTS LLC THIS DRAWING IS THE PROPERTY OF THE ARCHITECT AND IS NOT TO BE REPRODUCED IN WHOLE OR IN PART BY ANY MEANS OR METHOD WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ARCHITECT. ANY UNAUTHORIZED REPRODUCTION OR REUSE OF THESE DOCUMENTS WILL RESULT IN LEGAL ACTION. PROJECT CONTACT DATE NOT FOR CONSTRUCTION 2411 EXISTING CONDITIONS PHOTOS 9/30/24 AS102 FLATBREAD GRILL 2 N. FOREST BEACH DRIVE UNIT #101 HILTON HEAD ISLAND, SC 29928 ISSUED FOR REVIEW IMPROVEMENTS TO: JAD ID DESCRIPTION DATE Page 46 of 64 A201 2 A201 4 A201 1 A201 3 EXISTING FLATBREAD GRILL RESTAURANT EXISTING FABRIC AWNING AREA EXISTINGBAR WINDOW EXISTINGCOVERED PORCH EXISTING COVERED TRELLIS AREA (APPROXIMATE) CONCRETE DECK WOOD DECK TOPS OF POST TO BE REMOVED @ CHAMFER, TYP. A001 1 (TRELLIS TO REMAIN) 6" / 12" 6" / 12" 6" / 12" 6" / 12" 6" / 12" 6" / 12" 6" / 12" 6" / 12" EXISTING STANDING SEAM METAL ROOFING EXISTING COVERED TRELLIS AREA (APPROXIMATE) (TRELLIS TO REMAIN) (843) 284-7848 www.depauw.studio PO BOX 688 BLUFFTON, SC 29910 SHEET PROJECT NO. REVISIONS © COPYRIGHT 2024 DePAUW ARCHITECTS LLC THIS DRAWING IS THE PROPERTY OF THE ARCHITECT AND IS NOT TO BE REPRODUCED IN WHOLE OR IN PART BY ANY MEANS OR METHOD WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ARCHITECT. ANY UNAUTHORIZED REPRODUCTION OR REUSE OF THESE DOCUMENTS WILL RESULT IN LEGAL ACTION. PROJECT CONTACT DATE NOT FOR CONSTRUCTION 2411 DEMOLITION PLANS 9/30/24 AD101 FLATBREAD GRILL 2 N. FOREST BEACH DRIVE UNIT #101 HILTON HEAD ISLAND, SC 29928 ISSUED FOR REVIEW IMPROVEMENTS TO: JAD 1/8" = 1'-0"AD101 1 DEMOLITION FLOOR PLAN 1/8" = 1'-0"AD101 2 EXISTING ROOF PLAN ID DESCRIPTION DATE Page 47 of 64 DN A201 2 A201 4 INTERNAL ORIGIN A202 2 EXISTING FLATBREAD GRILL RESTAURANT EXISTING FABRIC AWNING AREA EXISTINGBAR WINDOW EXISTINGCOVERED PORCH EXISTING COVERED TRELLIS AREA (APPROXIMATE) BEAM ABOVE FOR NEW ROOF STRUCTURE, TYP. BEAM ABOVE FOR NEW ROOF STRUCTURE, TYP. NEW COVERED PORCH AREA EXISTING POSTS TO BE EXTENDED TO SUPPORT NEW ROOF STRUCTURE 3 A202 _______ CONCRETE DECK WOOD DECK (TRELLIS TO REMAIN) (843) 284-7848 www.depauw.studio PO BOX 688 BLUFFTON, SC 29910 SHEET PROJECT NO. REVISIONS © COPYRIGHT 2024 DePAUW ARCHITECTS LLC THIS DRAWING IS THE PROPERTY OF THE ARCHITECT AND IS NOT TO BE REPRODUCED IN WHOLE OR IN PART BY ANY MEANS OR METHOD WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ARCHITECT. ANY UNAUTHORIZED REPRODUCTION OR REUSE OF THESE DOCUMENTS WILL RESULT IN LEGAL ACTION. PROJECT CONTACT DATE NOT FOR CONSTRUCTION 2411 FIRST FLOOR PLAN 9/30/24 A102 FLATBREAD GRILL 2 N. FOREST BEACH DRIVE UNIT #101 HILTON HEAD ISLAND, SC 29928 ISSUED FOR REVIEW IMPROVEMENTS TO: JAD 1/4" = 1'-0"A102 1 RENOVATED FLOOR PLAN ID DESCRIPTION DATE Page 48 of 64 A201 2 A201 4 A202 2 6" / 12" 6" / 12" 6" / 12" 6" / 12" 6" / 12" 6" / 12" 1" / 12" 1" / 12" 1" / 12" 1" / 12" GALV. 6" HALF-ROUND GUTTER DOWNSPOUT W/ RAINCHAIN 3 A202 _______ EXISTING COVERED TRELLIS AREA (APPROXIMATE) (TRELLIS TO REMAIN) (843) 284-7848 www.depauw.studio PO BOX 688 BLUFFTON, SC 29910 SHEET PROJECT NO. REVISIONS © COPYRIGHT 2024 DePAUW ARCHITECTS LLC THIS DRAWING IS THE PROPERTY OF THE ARCHITECT AND IS NOT TO BE REPRODUCED IN WHOLE OR IN PART BY ANY MEANS OR METHOD WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ARCHITECT. ANY UNAUTHORIZED REPRODUCTION OR REUSE OF THESE DOCUMENTS WILL RESULT IN LEGAL ACTION. PROJECT CONTACT DATE NOT FOR CONSTRUCTION 2411 ROOF PLAN 9/30/24 A103 FLATBREAD GRILL 2 N. FOREST BEACH DRIVE UNIT #101 HILTON HEAD ISLAND, SC 29928 ISSUED FOR REVIEW IMPROVEMENTS TO: JAD 1/4" = 1'-0"A103 1 RENOVATED ROOF PLAN ID DESCRIPTION DATE Page 49 of 64 FIRST FLOOR 13'-1" AMSL ROOF BEARING 25'-1" AMSL GRADE 8'-1" AMSL B.O. EXISTING BEAM 22'-2" AMSL B.O. BEAM REMOVE TOP OF EXISTING POST @ CHAMFER AT INDICATED LOCATIONS REMOVE AWNING POST (AWNING MODIFICATIONS BY OTHERS TO MOUNT TO SIDE OF NEW CONSTRUCTION) 3 A202 _______ FIRST FLOOR 13'-1" AMSL ROOF BEARING 25'-1" AMSL GRADE 8'-1" AMSL B.O. BEAM GALV. KNIFE PLATE CONNECTION W/ STRAPPING DETAIL TR. 6x6 POST TO EXTEND EXISTING TR. 3x8 EXPOSED RAFTERS STANDING SEAM METAL ROOFING TO MATCH EXISTING EXISTING ATTIC VENT LOUVERS & SIGNAGE TO REMAIN EXISTING RAILING & DECK STRUCTURE TO REMAIN GALV. 6" HALF-ROUND GUTTER W/ DOWNSPOUT & RAINCHAIN RAINCHAIN TO 2'x2'x4' GRAVEL DRYWELL 3 A202 _______ 6" 12" FIRST FLOOR 13'-1" AMSL ROOF BEARING 25'-1" AMSL GRADE 8'-1" AMSL B.O. EXISTING BEAM 22'-2" AMSL B.O. BEAM REMOVE TOP OF EXISTING POST @ CHAMFER AT INDICATED LOCATIONS FIRST FLOOR 13'-1" AMSL ROOF BEARING 25'-1" AMSL GRADE 8'-1" AMSL B.O. BEAM GALV. KNIFE PLATE CONNECTION W/ STRAPPING DETAIL TR. 6x6 POST TO EXTEND EXISTING TR. 3x8 EXPOSED RAFTERS STANDING SEAM METAL ROOFING TO MATCH EXISTING EXISTING RAILING & DECK STRUCTURE TO REMAIN GALV. 6" HALF-ROUND GUTTER W/ DOWNSPOUT & RAINCHAIN1" 12" (843) 284-7848 www.depauw.studio PO BOX 688 BLUFFTON, SC 29910 SHEET PROJECT NO. REVISIONS © COPYRIGHT 2024 DePAUW ARCHITECTS LLC THIS DRAWING IS THE PROPERTY OF THE ARCHITECT AND IS NOT TO BE REPRODUCED IN WHOLE OR IN PART BY ANY MEANS OR METHOD WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ARCHITECT. ANY UNAUTHORIZED REPRODUCTION OR REUSE OF THESE DOCUMENTS WILL RESULT IN LEGAL ACTION. PROJECT CONTACT DATE NOT FOR CONSTRUCTION 2411 ELEVATIONS 9/30/24 A201 FLATBREAD GRILL 2 N. FOREST BEACH DRIVE UNIT #101 HILTON HEAD ISLAND, SC 29928 ISSUED FOR REVIEW IMPROVEMENTS TO: JAD 1/4" = 1'-0"A201 1 DEMO FRONT ELEVATION 1/4" = 1'-0"A201 2 RENOVATED FRONT ELEVATION 1/4" = 1'-0"A201 3 DEMO LEFT ELEVATION 1/4" = 1'-0"A201 4 RENOVATED LEFT ELEVATION ID DESCRIPTION DATE Page 50 of 64 FIRST FLOOR 13'-1" AMSL ROOF BEARING 25'-1" AMSL GRADE 8'-1" AMSL B.O. EXISTING BEAM 22'-2" AMSL B.O. BEAM REMOVE TOP OF EXISTING POST @ CHAMFER AT INDICATED LOCATIONS REMOVE AWNING POST (AWNING MODIFICATIONS BY OTHERS TO MOUNT TO SIDE OF NEW CONSTRUCTION) FIRST FLOOR 13'-1" AMSL ROOF BEARING 25'-1" AMSL GRADE 8'-1" AMSL B.O. BEAM FIRST FLOOR 13'-1" AMSL GRADE 8'-1" AMSL B.O. BEAM EXISTING HANDRAIL TO REMAIN HIDDEN FOR CLARITY FLAT STEEL PLATE ON KNIFE PLATE @ T.O. EXISTING POST BOLTED KNIFE PLATE CONNECTION B/W EXISTING & NEW POSTS BANDING TO RETAIN EXISTING POST TR. 4x10 BEAM GALV. 6" HALF-ROUND GUTTER (SEE ROOF PLAN FOR LOCATION) TR. 3x8 EXPOSED RAFTER (CUT TO MATCH TRELLIS) T1-11 PORCH CEILING ROOF SHEATHING (SEE STRUCTURAL) HIGH-TEMP ICE & WATER SHIELD STANDING SEAM METAL ROOFING TO MATCH EXISTING DRIP EDGE FLASHING TOE NAILED TIMBER SCREWS FOR UPLIFT RESISTANCE EXISTING DECK TO REMAIN EXISTING 6x6 POST TO REMAIN TR. 6x6 POST 96" 1" 12" 8'-0" AFF R5" (843) 284-7848 www.depauw.studio PO BOX 688 BLUFFTON, SC 29910 SHEET PROJECT NO. REVISIONS © COPYRIGHT 2024 DePAUW ARCHITECTS LLC THIS DRAWING IS THE PROPERTY OF THE ARCHITECT AND IS NOT TO BE REPRODUCED IN WHOLE OR IN PART BY ANY MEANS OR METHOD WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ARCHITECT. ANY UNAUTHORIZED REPRODUCTION OR REUSE OF THESE DOCUMENTS WILL RESULT IN LEGAL ACTION. PROJECT CONTACT DATE NOT FOR CONSTRUCTION 2411 ELEVATIONS 9/30/24 A202 FLATBREAD GRILL 2 N. FOREST BEACH DRIVE UNIT #101 HILTON HEAD ISLAND, SC 29928 ISSUED FOR REVIEW IMPROVEMENTS TO: JAD 1/4" = 1'-0"A202 1 DEMO RIGHT ELEVATION 1/4" = 1'-0"A202 2 RENOVATED RIGHT ELEVATION 1" = 1'-0"A202 3 COLUMN DETAIL ID DESCRIPTION DATE Page 51 of 64 (843) 284-7848 www.depauw.studio PO BOX 688 BLUFFTON, SC 29910 SHEET PROJECT NO. REVISIONS © COPYRIGHT 2024 DePAUW ARCHITECTS LLC THIS DRAWING IS THE PROPERTY OF THE ARCHITECT AND IS NOT TO BE REPRODUCED IN WHOLE OR IN PART BY ANY MEANS OR METHOD WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ARCHITECT. ANY UNAUTHORIZED REPRODUCTION OR REUSE OF THESE DOCUMENTS WILL RESULT IN LEGAL ACTION. PROJECT CONTACT DATE NOT FOR CONSTRUCTION 2411 MASSING MODEL 9/30/24 A203 FLATBREAD GRILL 2 N. FOREST BEACH DRIVE UNIT #101 HILTON HEAD ISLAND, SC 29928 ISSUED FOR REVIEW IMPROVEMENTS TO: JAD ENTRY MASSING RIGHT SIDE MASSING ID DESCRIPTION DATE Page 52 of 64 EX EX EX EXEX EX EX HEATER HEATER HEATER HEATER HEATER B B EXISTING LIGHTING TO REMAIN C A A A A AA EXTERIOR LIGHTING SCHEDULE MARK DESCRIPTION MANUFACTURER CATALOG NUMBER LAMP MOUNTING COLOR NOTES A FAN W/ LIGHT KIT MINKA-AIRE F753L-CL 3000K LED CEILING COAL B AIMABLE INFILL SPOT LIGHT B-K LIGHTING AR-LED-RM-X53-FL-BLP-9-11-A-3-WM WALL SATIN BLACK C WALL SCONCE HUKORO 13.3"H MATTE BLACK OUTDOOR WALL LIGHT WALL BLACK 3000K LED 3000K LED (843) 284-7848 www.depauw.studio PO BOX 688 BLUFFTON, SC 29910 SHEET PROJECT NO. REVISIONS © COPYRIGHT 2024 DePAUW ARCHITECTS LLC THIS DRAWING IS THE PROPERTY OF THE ARCHITECT AND IS NOT TO BE REPRODUCED IN WHOLE OR IN PART BY ANY MEANS OR METHOD WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ARCHITECT. ANY UNAUTHORIZED REPRODUCTION OR REUSE OF THESE DOCUMENTS WILL RESULT IN LEGAL ACTION. PROJECT CONTACT DATE NOT FOR CONSTRUCTION 2411 LIGHTING PLAN 9/30/24 AE101 FLATBREAD GRILL 2 N. FOREST BEACH DRIVE UNIT #101 HILTON HEAD ISLAND, SC 29928 ISSUED FOR REVIEW IMPROVEMENTS TO: JAD 1/4" = 1'-0"AE101 1 LIGHTING PLAN ID DESCRIPTION DATE Page 53 of 64 Image File Name:  F753L-CL.jpg Java - LED 54" Ceiling Fan Item #: F753L-CL UPC Code: 706411061936 Product Family Name: Java LED Finish: Coal Category: EXTERIOR FAN Category Type: Ceiling Fan Certification: E75795 Patents: Notes: LED Wet Location UL Listed MEASUREMENTS Blade Finish: Blade Material: PC Blade Sweep: 54" No. of Blades: 3 Blade Pitch: 14 DEGREES Reversible Blades: NO Slope: YES Hanging Weight: 17 .22 Downrod 1: 6 Downrod 1 Outside Dia: 0.75 Downroad 2: Downrod 2 Outside Dia: Ceiling to Lowest Point: (Dim A): 14.75 Ceiling to Blade (Dim B): 13.25 Lead Wire: 80" Power: AC Motor Size: AC 153 X 18mm Low Low/Med. Medium Med/High High RPM 79 156 Amps 0.218 0.391 Watts 14.51 47.27 CFM 2834.0 5771.0 CFM/Watts 195.31 122.09 LAMPING No. of Bulbs: 1 Max Bulb Wattage: 18 Light Type: Z32 LED Light Kit Optional: NO Socket: Y30 LED MODULE Integrated Light Kit: YES Dimmable: YES Ballast: Rated Life Hours: 30000 Uplight: NO Bulb/LED Included: YES Color Temp.: 3000 CRI: 92 Initial Lumens: 1489.1 Delivered Lumens: 488.9 GLASS Description: OPAL FROSTED Material: Part No.: GF753 Quantity: 1 Width: 7 .17 Height: 1.77 Length: 7 .17 CONTROLS Pull Chain Control: NO Works with Remote Control: YES Works with Wall Control: YES Reversible: YES Included Remote Control: RCS213 Included Wall Control: Smart Control: NO Compatible Remote Control(s): Compatible Wall Control(s): WCS213 Integrated Smart Control: Compatible Smart Control: BD-1000 SHIPPING Carton Width: 9.88 Carton Height: 10.5 Carton Length: 28.0 Carton Weight: 20.04 Carton Cubic Feet: 1.681 Small Package Shippable: YES Master Pack Width: Master Pack Height: Master Pack Length: Master Pack Weight: Master Cubic Feet: Multi-Pack: 1 Master Pack: 1 WARNING: Handling this product can expose you to chemicals including lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm. Wash hands with soap and water after installing, handling, cleaning or otherwise touching this product. For more information go to: www.P65Warnings.ca.gov. For additional information, please contact Customer Care: 1-800-221-7977 | Product depicted on this spec sheet is protected by United States Federal and/or State laws including US Patent, Trademark and/or Copyright and unfair competition laws. Unauthorized reproduction or use carries severe legal penalties. Rev 01.10.2024 01:45 PM TYPE A Page 54 of 64 DATE : CATALOG NUMBER LOGIC: PROJECT: TYPE: THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF B-K LIGHTING, INC. AND ITS RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE, DISCLOSE ITS CONTENTS, OR TO MANUFACTURE, USE OR SELL ANYTHING IT MAY DESCRIBE. REPRODUCTION, DISCLOSURE OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF B-K LIGHTING, INC. IS STRICTLY FORBIDDEN. 559.438.5800 | INFO@BKLIGHTING.COM | BKLIGHTING.COMMADE IN THE USA Driver housing required. Configure separately. ARTISTAR LED (REMOTE DRIVER) CATALOG NUMBER LOGIC Example: B - AR - LED - RM - x54 - FL - POL - 12 - 11 - B - 6 - WM MATERIAL (Blank) - Aluminum B - Brass S - Stainless Steel SERIES AR - ArtiStar SOURCE LED - Chip on Board Technology HOUSING RM - Remote Driver LED TYPE x52 - 10W LED/2700K x53 - 10W LED/3000K x54 - 10W LED/4000K OPTICS SP - Spot (20°) FL -Flood (40°) WFL - Wide Flood (60°) FINISH (See page 2 for full-color swatches) Standard Finishes (BZP, BZW, BLP, BLW, WHP, WHW, SAP, VER) Premium Finish (ABP, AMG, AQW, BCM, BGE, BPP, CAP, CMG, CRM, HUG, NBP, OCP, RMG, SDS, SMG, TXF, WCP, WIR) Also available in RAL Finishes Brass Finishes (MAC, POL, MIT) Stainless Steel Finishes (MAC, POL) LENS TYPE 9 - Clear (Standard) 12 - Soft Focus 13 - Rectilinear SHIELDING 11 - Honeycomb Baffle CAP STYLE A - 45° B - 90° C - Flush D - 45° Less Weephole (Interior use only) E - 90° Less Weephole (Interior use only) F - 90° with Flush Lens BASE HEIGHT 3” (Standard), 6” , 12” , 18” , & 24” with Anchor Base MOUNTING OPTIONS PP - 18” Power Pipe Stake Mount SF - Stability Flange (For use with Power Pipe) WM - Wall or Ceiling Mount with 5” dia. Machined Canopy** IP66 RATED 12/06/2022 SKU-1015 *Base height limited to 6” max. with Brass and Stainless Steel Canopy. SUB-2126-00 TYPE B Page 55 of 64 DAT E : PROJECT: TYPE: THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF B-K LIGHTING, INC. AND ITS RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE, DISCLOSE ITS CONTENTS, OR TO MANUFACTURE, USE OR SELL ANYTHING IT MAY DESCRIBE. REPRODUCTION, DISCLOSURE OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF B-K LIGHTING, INC. IS STRICTLY FORBIDDEN. 559.438.5800 | INFO@BKLIGHTING.COM | BKLIGHTING.COMMADE IN THE USA Satin Black (BLP) Satin Bronze (BZP) Satin White (WHP) Black Wrinkle (BLW) Bronze Wrinkle (BZW) White Wrinkle (WHW) Verde (VER) Satin Aluminum (SAP) Cascade Mtn. Granite (CMG) Black Chrome (BCM) Weathered Iron (WIR) Rocky Mtn. Granite (RMG) Beige (BGE) Clear Anodized Powder (CAP) Sierra Mtn Granite (SMG) Weathered Copper (WCP) Antique Brass Powder (ABP) Cream (CRM) Aleutian Mtn Granite (AMG) Old Copper (OCP) Brown Patina Powder (BPP) Antique White (AQW) Textured Forest (TXF) Hunter Green (HUG) Sonoran Desert Sandstone (SDS) Natural Brass Powder (NBP) STANDARD FINISHES PREMIUM FINISHES Click Here to view larger, full-color swatches of all available finishes on our website. C CAP F CAP (38mm) 1 1/2” (51mm) 2" (114mm) 4 1/2" 3 1/8" (79mm) A/D CAP B/E CAP 2 3/8" (60mm) 1" (25mm) 1/8" (3mm) 3" (76mm) 4 1/2" (114mm) 2 1/4" Dia. (57mm) 6" (152mm) (610mm) 24" 18" (457mm) (305mm) 12" 2 1/4" Dia. (57mm) 7/8 Dia. (22mm)1 /4" Dia. (6mm) at 120° STANDARD BASE WALL MOUNT CANOPY POWER PIPE 5/8” (16mm) 3 1/2" O.C. (89mm) 5" Dia. (127mm) 3/8” (10mm) Stability Flange (Optional) 6" Dia (152mm) 7/8" (22 mm) 18” (457mm) 1" (25mm) ARTISTAR LED (REMOTE DRIVER) IP66 RATED 12/06/2022 SKU-1015 SUB-2126-00 TYPE B Page 56 of 64 DATE : PROJECT: TYPE: Accessories (Configure separately) SPECIFICATIONS THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF B-K LIGHTING, INC. AND ITS RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE, DISCLOSE ITS CONTENTS, OR TO MANUFACTURE, USE OR SELL ANYTHING IT MAY DESCRIBE. REPRODUCTION, DISCLOSURE OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF B-K LIGHTING, INC. IS STRICTLY FORBIDDEN. 559.438.5800 | INFO@BKLIGHTING.COM | BKLIGHTING.COMMADE IN THE USA ELECTRICAL PHYSICAL WAT TAGE 10W LED WIRING Teflon® coated, 18AWG, 600V, 250° C rated and certified to UL 1659 standard. REMOTE DRIVER For use with remote LED driver. See remote driver submittal to determine remote distance and wiring requirements prior to detailing field installation of any remote wiring. MATERIALS Furnished in copper-free aluminum (6061-T6), brass (360) or stainless steel (304). BODY Unibody design with enclosed, water-proof wireway and integral heat sink is fully machined from solid billet. KNUCKLE Aim & Lock knuckle is integral to the body and features an interior taper machined from solid billet and a reverse angle taper allowing full 18° vertical adjustment without the use of aim-limiting serrated teeth. High temperature, silicone ‘O’ Ring provides water-tight seal and compressive resistance to maintain fixture position. Design withstands 73 lbs. static load prior to movement for optical alignment with a ½” pipe thread for mounting. Optional 360SL provides biaxial source control with 360° horizontal rotation in addition to vertical adjustment. CAP Fully machined and accommodates two (2) lens or louver media. LENS Shock-resistant, tempered glass lens is factory adhered to fixture cap and provides hermetically sealed optical compartment. LED Integrated solid state system and modular design with electrical disconnects allow for easy field upgrade and maintenance. LM-80 certified. Minimum 50,000 hour rated life at 70% of initial lumens (L70). LED technology provides long life, significant energy reduction and exceptional thermal management. COLOR MANAGEMENT Corrected cold phosphor technology delivers natural white light with long term phosphor maintenance over product life. Exact color point conformity exceeds ANSI C78.377 standard. Provides uniform beam with no color variation over angle. Module exceeds 80 CRI (RA>80, R9>16). INSTALLATION Available for installation in three distinct mounting conditions: ANCHOR BASE (STANDARD) Machined anchor base with 7/8” dia. slip conduit hole and (3) 3/16” dia. anchor bolt holes (hardware by others). POWER PIPE (OPTIONAL) Provides a clean transition from wiring system to fixture. Schedule 80, 18” PVC housing for direct burial into soil or concrete. Machined 2 1/4” dia. cap for fixture mounting with stainless steel hardware. Optional 6” dia., molded stability flange, to simplify installation and projects into substrate to reinforce housing stability. WALL MOUNT CANOPY (OPTIONAL) Optional 5” dia. machined canopy permits mounting to junction box (gasket by others). 8” maximum base height for canopy-mounted brass or stainless steel fixture. OPTICS Interchangeable OPTIKIT modules permit optical field changes. Color-code: Narrow Spot (NSP) = red; Spot (SP) = green; Medium Flood (MFL) = yellow; Wide Flood (WFL) = blue. HARDWARE Tamper-resistant, stainless steel hardware. Knuckle vertical aiming screw is black oxide treated for additional corrosion resistance. FINISH StarGuard, our 15-stage chromate-free process cleans and conversion coats aluminum components prior to application of Class ‘A’ TGIC polyester powder coating and is RoHS compliant. Powder coat or metal finish options available for brass material and metal finish option only for stainless steel material. WARRANTY 5-year limited warranty. CERTIFICATION & LISTING ITL tested to IESNA LM-79. UL Listed. Certified to CAN/CSA/ANSI Standards. RoHS compliant. Suitable for indoor or outdoor use, in wet locations, and for installation within 4’ of the ground. IP66 Rated. Made in the USA with sustainable processes. HP2RMHP2RM PM2DRM & PM2RMPM2DRM & PM2RM DRM & RMDRM & RM ARTISTAR LED (REMOTE DRIVER) IP66 RATED 12/06/2022 SKU-1015 SUB-2126-00 TYPE B Page 57 of 64 DAT E : PROJECT: TYPE: THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF B-K LIGHTING, INC. AND ITS RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE, DISCLOSE ITS CONTENTS, OR TO MANUFACTURE, USE OR SELL ANYTHING IT MAY DESCRIBE. REPRODUCTION, DISCLOSURE OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF B-K LIGHTING, INC. IS STRICTLY FORBIDDEN. 559.438.5800 | INFO@BKLIGHTING.COM | BKLIGHTING.COMMADE IN THE USA LAMP & DRIVER DATA (x52, x53, x54) LM79 DATA L70 DATA OPTICAL DATA BK No. Lumens (Source) CCT (Typ.) CRI (Ra.Typ.) Input Watts (Tpy.) Minimum Rated Life (hrs.) 70% of initial lumens (L70) Beam Type Angle CBCP x52 1180 2700K 80 10 50,000 Spot 20° 2680 x53 1230 3000K 80 10 50,000 Flood 40° 1744 x54 1280 4000K 80 10 50,000 Wide Flood 60° 640 TYPE B Page 58 of 64 TYPE C Page 59 of 64 TYPE C Page 60 of 64 1 DESIGNDESIGN TEAM/DRBTEAM/DRB COMMENTCOMMENT SHEETSHEET TheThe commentscomments belowbelow areare staffstaff recommendationsrecommendations toto thethe DesignDesign ReviewReview BoardBoard (DRB)(DRB) andand dodo NOTNOT constituteconstitute DRBDRB approvalapproval oror denial.denial. PROJECT NAME: 2 North Forest Beach Drive, #101 – Flatbread Grill DRB-001353-2024 DATE: 10/22/2024 CATEGORY: Roof Addition RECOMMENDATION: Approval Approval with Conditions Denial APPLICATION MATERIAL DRB REQUIREMENTS Complies Yes No Not Applicable Comments or Conditions Demolition Plan if needed Existing Conditions match As-Built There is a section of roofing that was never approved or received building permits for that is not part of this proposal yet part of the roof plan. This area should be address as well as the proposed roof addition. Dimensioned Details and of Sections Detail Illustrating Connection to Existing Structure New Building Details Match Existing Building Details ARCHITECTURAL DESIGN DESIGN GUIDE/LMO CRITERIA Complies Yes No Not Applicable Comments or Conditions Structure is designed to be appropriate to the neighborhood Promotes pedestrian scale and circulation Design is unobtrusive and set into the natural environment Utilizes natural materials and colors Provide a 11” x 17” material and color board. Page 61 of 64 2 Avoids distinctive vernacular styles Design is appropriate for its use All facades shall have equal design characteristics Avoids monotonous planes or unrelieved repetition Has a strong roof form with enough variety to provide visual interest Overhangs are sufficient for the façade height. Forms and details are sufficient to reduce the mass of the structure Human scale is achieved by the use of proper proportions and architectural elements Utilizes a variety of materials, textures and colors Incorporates wood or wood simulating materials Windows are in proportion to the facade Details are clean, simple and appropriate while avoiding excessive ornamentation Utilities and equipment are concealed from view Decorative lighting is limited and low wattage and adds to the visual character Accessory elements are designed to coordinate with the primary structure LANDSCAPE DESIGN DESIGN GUIDE/LMO CRITERIA Complies Yes No Not Applicable Comments or Conditions Treats the Landscape as a major element of the project Provide existing and proposed landscape plan. Provides Landscaping of a scope and size that is in proportion to the scale of the development Landscape is designed so that it may be maintained in its natural shape and size Preserves a variety of existing native trees and shrubs Provides for a harmonious setting for the site’s structures, parking areas or other construction Location of existing trees and new trees provides street buffers, mitigation for parking lots, and an architectural complement that visually mitigates between parking lots and building(s) Shrubs are selected to complement the natural setting, provide visual interest and screen less-desirable elements of the project Page 62 of 64 3 A variety of species is selected for texture and color Provides overall order and continuity of the Landscape plan Native plants or plants that have historically been prevalent on the Island are utilized A variety of sizes is selected to create a “layered” appearance for visual interest and a sense of depth The location of existing mature trees is taken into account in placement of shrubs so as not to damage tree roots Proper spacing and location for plants to reach their mature size and natural shape while avoiding excessive or unnatural pruning Proposed groundcovers are evergreen species with low maintenance needs Large, grassed lawn areas encompassing a major portion of the site are avoided The adjacent development is taken into account in determining the most appropriate buffer so as not to depart too dramatically from the neighborhood Ornamentals and Annuals are limited to entrances and other focal points NATURAL RESOURCE PROTECTION DESIGN GUIDE/LMO CRITERIA Complies Yes No Not Applicable Comments or Conditions An effort has been made to preserve existing trees and under story plants Supplemental and replacement trees meet LMO requirements for size, species and number Wetlands if present are avoided and the required buffers are maintained Sand dunes if present are not disturbed COMMENTS & CONDITIONS 1. Staff recommends approval of the conceptual design submittal with the following conditions: a. Provide an existing and proposed landscape plan. b. Provide a lighting plan. c. Provide a 11” x 17” material and color board. 2. Any additional information as required by the Board. Page 63 of 64 4 Page 64 of 64

Source: Town of Hilton Head Island website. First collected Nov 10, 2026.