Design Review Board Meeting — Agenda Packet
Town of Hilton Head Island · Beaufort County · Design Review Board · meeting of Oct 22, 2024 · Agenda packets
Open the original document More from Town of Hilton Head Island
Text
Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.
Town of Hilton Head Island
Design Review Board Meeting
Tuesday, October 22, 2024, 2:30 PM
1 Town Center Court, Hilton Head Island, SC
Conference Room #4
1. Call to Order
2. Adoption of the Agenda
3. Approval of the Minutes
a. Regular Meeting Minutes of October 8th, 2024.
4. Unfinished Business
5. New Business
a. DRB-001353-2024 - 2 North Forest Beach Drive - Flatbread Grill - Roof
addition
6. Public Comment - Non Agenda Items
7. Board Business
8. Staff Reports
9. Adjournment
FOIA Compliance: Public notification of this meeting has been published, posted, and
distributed in compliance with the South Carolina Freedom of Information Act and the
requirements of the Town of Hilton Head Island.
In accordance with the requirements of Title II of the Americans with Disabilities Act of
1990 ("ADA"), the Town of Hilton Head Island will not discriminate against qualified
individuals with disabilities on the basis of disability in its services, programs, or
activities. Auditory accommodations are available. Any person requiring further
accommodation should contact the Town of Hilton Head Island ADA Coordinator as
Page 1 of 64
soon as possible but no later than 48 hours before the scheduled event.
Municipal Association of South Carolina (MASC) Civility Pledge:
“I pledge to build a stronger and more prosperous community by advocating for civil
engagement, respecting others and their viewpoints, and finding solutions for the
betterment of my city or town.”
Page 2 of 64
Town of Hilton Head Island Design Review Board
Meeting Minutes
10/8/2024 Page | 1
Town of Hilton Head Island
DESIGN REVIEW BOARD MEETING
Tuesday, October 8, 2024, 2:30 PM
Minutes
1. Call to Order
Chair Carstens called the meeting to order at 2:31 PM.
2. Adoption of the Agenda
Mr. Parker made a motion to adopt the agenda as presented. The motion was seconded by
Vice-Chair Lippert.
3. Approval of the Minutes
a. Regular Meeting Minutes of September 24th, 2024.
Vice-Chair Lippert made a motion to approve the minutes of September 24th, 2024. The
motion was seconded by Ms. Pastor.
4. Unfinished Business
None
5. New Business
a. DRB-001286-2024 - 2 Park Lane - Sign
Melissa Paul-Leto, Principal Planner of Design, presented the application for two new
signs that would replace two older signs located at 2 Park Lane. Staff recommended
approval with the following conditions: provide photos of existing signage as well as show
exterior lighting and landscaping around the signage. The applicant, Shawn Congleton of
Sign Design, explained that the complex is under new ownership and the current owner is
looking to update the signs to provide a more modern feel and look.
There was discussion among the board regarding color palette as the proposed image
displayed colors that do not coincide with what is stated in the Design Guide. The board
members also went into a hefty discussion regarding the dimensions of the proposed
signs, ultimately suggesting that with the larger size of Sign A, Sign B should be smaller
than what is currently being shown. Vice-Chair Lippert referenced Park Plaza, which she
stated is a "much larger complex" with only one sign. Staff will verify whether the
proposed signs are in compliance with buffers and max allowable sign quantity for the site
and building size.
With certain critical elements unclear at this stage, Chair Carstens suggested to the
Page 3 of 64
Town of Hilton Head Island Design Review Board
Meeting Minutes
10/8/2024 Page | 2
applicant that this item be tabled so that he could return at his next available opportunity
with the necessary requests from the board. The applicant agreed to table the item and
return at the October 22nd, 2024 meeting.
b. DRB-001328-2024 - Coligny Circle Pocket Park - Conceptual
Mr. Theodore recused himself.
Melissa Paul Leto, Principal Planner of Design, presented the application for the Coligny
Circle Pocket Park intended to be a civic gathering space that will also allow for
pedestrian connectivity between Pope Avenue and North Forest Beach as well as a multi-
use path to the adjacent commercial center. Staff recommended approval with the
following conditions: screening utilities, providing lighting plans as well as existing and
proposed landscape plans, and approval letter from the Forest Beach HOA.
The board initially touched on landscaping and trees before going into discussion
regarding furnishings. The applicant provided details and explained the furnishings would
be fixed, which was a concern of the board with the consideration of hurricane season.
Vice-Chair Lippert suggested that the trash receptacles be a bit closer to the bike racks
for pedestrian convenience to avoid a litter issue. Ms. Pastor also suggested that the
addition of pet waste receptacles be studied. Chair Carstens had some additional
questions regarding landscaping and hose bibs. He then suggested there be additional
plantings in the far corner of the park next to the neighboring coffee shop. Chair Carstens
also inquired about the Coligny sign that currently resides in the proposed park space to
which the applicant explained that they are working with the Town to come to a decision
on potential removal or replacement.
Vice-Chair Lippert made a motion to approve with the following conditions: staff
comments be addressed, verify screening of transformers, review table selections, study
trash bin locations, downplay coffee shop access, study wall caps, clarify plans for
monument sign, and consider adding pet waste elements. The motion was seconded by
Mr. Parker and passed with a note of 5-0-0.
c. DRB-001329-2024 - 59 Pope Avenue - Pavillian at The Bank - Conceptual
Mr. Theodore returned to the Dias. Chair Carstens recused himself and passed the gavel
to Vice-Chair Lippert.
Melissa Paul-Leto, Principal Planner of Design, presented the application for 59 Pope
Avenue. The narrative of the application is the request for an open-air Pavilion located at
59 Pope Avenue, an existing restaurant called "The Bank." The proposed Pavilion is
intended to be a 10-sided structure surrounding an existing fully designed space on the
property. Staff recommended approval with the following conditions: provision of
elevations, renderings of landscaping for subject areas, 11x17 material and color board,
screening of utilities on site, as well as lighting and landscape plans. The applicant, Billy
Watterson, owner of The Bank, provided additional comments regarding the structural
intent.
Page 4 of 64
Town of Hilton Head Island Design Review Board
Meeting Minutes
10/8/2024 Page | 3
The board discussed the color selection to which the applicant provided clarification
stating that his selection of "Charleston Green" matches the current entry point, and he
believes it will also blend nicely with the natural landscape. Mr. Parker inquired about the
inspiration behind the selection of wood for the posts to which the application replied that
the trellises are composed of the same material. Ms. Pastor inquired about the potential
addition of fans in the pavilion. The applicant clarified that the two-layer roof is intended to
encourage airflow throughout the space. Vice-Chair Lippert suggested that the applicant
include the large screen adjacent to the Pavilion in their elevations at the final review
stage for reference and context purposes solely. Mr. Parker suggested the screen be
noted in the final renderings as "not being reviewed" for clarification.
Mr. Parker made a motion to approve with the following conditions: staff comments be
addressed, include bar and screen in renderings, and the colors match the existing entry
point. The motion was seconded by Ms. Fitzpatrick and passed with a vote of 5-0-0.
6. Public Comment - Non Agenda Items
Chair Carstens returned to the Dias and Vice-Chair Lippert passed the gavel back.
There was no public comment.
7. Board Business
Vice-Chair Lippert inquired about voting parameters which Staff addressed and is hoping to
have clear direction for the board on a number of items at the next meeting. The board also
asked about the possibility of a collaborative Design Guide rewrite and is awaiting an LMO
timeline update from Ms. Paul-Leto.
8. Staff Reports
Melissa Paul-Leto gave various Minor Corridor Reports.
9. Adjournment
The meeting was declared adjourned at 4:11 PM.
The recording of this Meeting can be found on the Town’s website
at www.hiltonheadislandsc.gov
Page 5 of 64
Page 6 of 64
Last Revised 01/21/15 1
Applicant/Agent Name: ______________________________ Company: _____________________________________ Mailing Address: ___________________________________ City: _________________ State: ______ Zip: ________ Telephone: ___________________ Fax: _________________ E-mail: _______________________________________ Project Name: _________________________________ Project Address: _____________________________________ Parcel Number [PIN]: R__ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ Zoning District: _______________________________ Overlay District(s): ___________________________________ Town of Hilton Head IslandCommunity Development DepartmentOne Town Center Court Hilton Head Island, SC 29928 Phone: 843-341-4757 Fax: 843-842-8908 www.hiltonheadislandsc.gov
CORRIDOR REVIEW, MAJORDESIGN REVIEW BOARD (DRB) SUBMITTAL REQUIREMENTSDigital Submissions may be accepted via e-mail by calling 843-341-4757.Project Category:_____ Concept Approval – Proposed Development _____ Alteration/Addition_____ Final Approval – Proposed Development _____ Sign
FOR OFFICIAL USE ONLYDate Received: _____________ Accepted by:______________DRB #:___________________Meeting Date:_____________
Submittal Requirements for All projects:_____ Private Architectural Review Board (ARB) Notice of Action (if applicable): When a project is within the jurisdiction of an ARB, the applicant shall submit such ARB’s written notice of action per LMO Section 16-2-103.I.4.b.iii.01. Submitting an application to the ARB to meet this requirement is the responsibility of the applicant. _____ Filing Fee: Concept Approval-Proposed Development $175, Final Approval – Proposed Development $175, Alterations/Additions $100, Signs $25; cash or check made payable to the Town of Hilton Head Island.Additional Submittal Requirements:Concept Approval – Proposed Development_____A survey (1"=30' minimum scale) of property lines, existing topography and the location of trees meeting the tree protection regulations of Sec. 16-6-104.C.2, and if applicable, location of bordering streets, marshes and beaches. _____ A site analysis study to include specimen trees, access, significant topography, wetlands, buffers, setbacks, views, orientation and other site features that may influence design. _____ A draft written narrative describing the design intent of the project, its goals and objectives and how it reflects the site analysis results. _____ Context photographs of neighboring uses and architectural styles. _____ Conceptual site plan (to scale) showing proposed location of new structures, parking areas and landscaping. _____ Conceptual sketches of primary exterior elevations showing architectural character of the proposed development, materials, colors, shadow lines and landscaping.
DePauw ArchitectsJoe DePauwPO Box 688BlufftonSC29910(843) 284-7848joe@depauw.studioImprovements to Flatbread Grill2 N Forest Beach Dr., #101CR (Coligny Resort)Corridor OverlayX
Page 7 of 64
Last Revised 01/21/15 2Note: All application items must be received by the deadline date in order to be reviewed by the DRB per LMO Appendix D: D-23.A representative for each agenda item is strongly encouraged to attend the meeting.Are there recorded private covenants and/or restrictions that are contrary to, conflict with, or prohibit the proposed request? If yes, a copy of the private covenants and/or restrictions must be submitted with this application. YES NOTo the best of my knowledge, the information on this application and all additional documentation is true, factual, and complete. I hereby agree to abide by all conditions of any approvals granted by the Town of Hilton Head Island. I understand that such conditions shall apply to the subject property only and are a right or obligation transferable by sale.I further understand that in the event of a State of Emergency due to a Disaster, the review and approval times set forth in the Land Management Ordinance may be suspended. SIGNATURE DATE
Additional Submittal Requirements:Final Approval – Proposed Development_____ A final written narrative describing how the project conforms with the conceptual approval and design review guidelines of Sec. 16-3-106.F.3._____ Final site development plan meeting the requirements of Appendix D: D-6.F. _____ Final site lighting and landscaping plans meeting the requirements of Appendix D: D-6.H and D-6.I._____ Final floor plans and elevation drawings (1/8"=1'-0" minimum scale) showing exterior building materials and colors with architectural sections and details to adequately describe the project. _____ A color board (11"x17" maximum) containing actual color samples of all exterior finishes, keyed to the elevations, and indicating the manufacturer's name and color designation. _____ Any additional information requested by the Design Review Board at the time of concept approval, such as scale model or color renderings, that the Board finds necessary in order to act on a final application. Additional Submittal Requirements:Alterations/Additions _____ All of the materials required for final approval of proposed development as listed above, plus the following additional materials._____A survey (1"=30' minimum scale) of property lines, existing topography and the location of trees meeting the tree protection regulations of Sec. 16-6-104.C.2, and if applicable, location of bordering streets, marshes and beaches._____ Photographs of existing structure. Additional Submittal Requirements:Signs _____ Accurate color rendering of sign showing dimensions, type of lettering, materials and actual color samples.For freestanding signs:_____ Site plan (1”=30’ minimum scale) showing location of sign in relation to buildings, parking, existing signs, and property lines. _____ Proposed landscaping plan. For wall signs:_____ Photograph or drawing of the building depicting the proposed location of the sign. _____ Location, fixture type, and wattage of any proposed lighting.
**All colors match existing
9/30/2024
Page 8 of 64
Page 9 of 64
May 15, 2024
Town of Hilton Head Island
One Town Center Court
Hilton Head Island, SC 29928
Re: DRB Alteration/Addition Review
Improvements to Flatbread Grill & Bar
2 North Forest Beach Drive, #101
Hilton Head Island, SC 29928
R552 018 000 0012 0000
To whom it may concern,
In support of our DRB Review Submission, please find the attached plan set, application,
lighting cut-sheets and Forest Beach Owner’s Association approval. Our Project Narrative
follows below. Should you require additional information ahead of our meeting, please let me
know.
Scope of the Project:
The project proposes to add a roof over the uncovered dining terraces surrounding the
Flatbread Grill to the northwest and southwest. The roof will be low sloped and wrap around
the existing porch gable at the top of the stairs from the parking lot. The gable and signage will
remain as a prominent architectural element signifying the entry and to break up the massing of
the western facade. The new roofing will be standing seam metal to match the existing roof
and the appearance of the improvements have been developed to relate to the existing
structure and courtyard trellis.
The existing deck structure & railings will remain as structurally feasible. If the existing posts are
not capable of carrying the additional loads, the decking will be temporarily supported while
new taller posts (and new footings if required) are installed. The deck structure will then be re-
attached to the columns.
Building Areas:
The development consist of three (3) existing, raised one-story buildings with a combined
conditioned area of approximately 15,750 sq. ft. (12,910 sq. ft. + 2,360 sq. ft. + 480 sq. ft.). This
project will not change the number of structures, conditioned square footage, or the amount of
outdoor dining area.
Maintenance Responsibility:
Maintenance of the new roof structure will be by the owners of the Flatbread Grill.
Page 10 of 64
Tree Removal & Mitigation:
The existing deck structure was constructed around a 14” Live Oak. We propose to remove the
tree with the new roof addition. Two new Live Oak trees meeting the requirements of LMO 16-
6-104.I.3 will be located on-site where indicated on the site plan.
Setbacks & Buffers:
The property is zoned Coligny Resort and is separated from the edge of the zone by a ToHHI
owned park parcel. As a result, there is not an Adjacent Use setback along the west property
line. Per LMO Sec. 16-3-105.B.3, Adjacent Use Setback Requirements “shall apply only along
the perimeter of the CR district.”
There is not an Adjacent Street setback as the west property line does not adjoin a street.
No Adjacent Use Buffers are required between Commercial Services & Public Use along the
west property line.
The property lines from the North & South edges of the property do not effect the project.
Site Coverage:
This project will not change the impervious coverage on the site.
Utilities:
The project will rely on existing service to the restaurant for electrical needs. Plumbing and
mechanical service are not required by the improvements.
Grading:
The raised nature of the structure will be maintained, and the existing grading will remain.
Page 11 of 64
In addition, we are providing the following notes on the staff comments provided during pre-
application review:
Development Review
1. This project requires a Major Development Plan Review (DPR) application. Submit all of
the applicable materials listed in LMO Appendix D-6.
a. The Major DPR application is attached.
2. Show all building and site improvements on the plan, including HVAC units, utility
equipment and pedestals, and stairs.
a. All improvements are shown on the plans. There are no new HVAC units,
utility equipment, pedestals or stairs proposed.
3. This project requires a Major Corridor Review application. Submit all of the applicable
materials listed in LMO Appendix D-9.
a. This application will be submitted separately to the DRB.
4. Provide encroachment permits or approvals from all applicable outside agencies such as
DHEC, OCRM, PSD, Hargray, Palmetto Electric, any applicable private ARB, SCDOT,
Beaufort County, etc.
a. No encroachments are anticipated to be required. Private ARB approval from
the Forest Beach Owner’s Association is attached.
5. Provide a table on the plans with the following information for your project:
a. Please find this table at the bottom left of sheet AS101 Site Development Plan.
6. If the proposed project is to be constructed in phases, provide a phasing plan indicating
what is to be completed in each phase of the project.
a. This project will not be phased.
7. LMO Section 16-5-102.C. – North Forest Beach Drive, from Coligny Circle to Avocet St.,
is classified as a Minor Arterial with an adjacent street setback of 30 feet. Please
delineate all setbacks on plans.
a. Please refer to sheet AS101 Site Development Plan. The setback does not
effect the proposed scope of work area.
8. LMO Section 16-5-108 – Provide a site lighting plan for any new site lighting proposed.
a. No new site lighting is proposed.
Stormwater Engineering
9. Please have applicant review and complete a Stormwater Erosion Control Affidavit.
a. The completed Stormwater Erosion Control Affidavit is attached.
Natural Resources
10. The 14" Live Oak proposed for removal will require mitigation. Provide a landscaping
plan that shows tree mitigation at the rate of (1) tree for every 10” being removed, by
category.
a. Two (2) new Live Oak trees meeting the requirements of LMO 16-6-104.I.3 will
be located on-site where indicated on sheet AS101 Site Development Plan.
Page 12 of 64
11. Tree Protection Zones Sec. 16-6-104 - Tree protection zones for any trees located within
25' of any proposed grading, construction, or tree removals; to be established by
physical barriers that will need to be maintained until such time that the work is
completed. SPECIAL ATTENTION must be shown for the Specimen tree protection
areas that prevent paving or soil compaction within 15' of the trunk. These Specimen
tree protection zones should be substantial, such as cyclone or wooden fencing that will
prevent access to these 15' areas or material storage of any kind.
a. Tree protection will be provided for trees within 25 feet of the construction.
No specimen trees are within this area.
12. Tree Protection/Preservation, Sec. 16-6-104.B.1.a - All persons are required to make all
reasonable efforts to preserve and retain any existing stands of trees, individual trees,
and other self-supporting plants, whether or not such plants are protected under this
section, as well as such other flora that make up part of the understory, shrub layer, or
herb layer.
a. Minimal understory, shrub layer or herb layer exist in the proposed scope of
work area.
Urban Design Review
13. This project requires review/approval from the Town’s Design Review Board under a
Major Corridor Review submittal. Major Corridor reviews are a design review consisting
of two reviews by the Board. The first is a Conceptual Review for direction and feedback
from the Board. The second review is considered the Final Review and should consist of
a complete design set with appropriate material and color boards. Please see
application and checklist for more information. The application form can be found here:
https://hiltonheadislandsc.gov/forms/bldgdev/DesignReviewApp.pdf You can also
contact Alexis McIlwee at 843-341-4676 or alexism@hiltonheadislandsc.gov for more
information.
a. This application will be submitted separately to the DRB.
Thank you for your time and consideration,
Joseph DePauw, AIA
Principal
DePauw Architects
Page 13 of 64
Page 14 of 64
Page 15 of 64
Page 16 of 64
FOREST BEACH OWNERS’ ASSOCIATION, INC.
P O Box 6442
Hilton Head Island, SC 29938-6442
(843)785-5565 FAX (843) 342-3801
Email: FBAssn@gmail.com
September 23, 2024
Allstar, LLC Re: 2 NFB DR – Exterior
Attn: Mr. Alan Mintz & Mr. Amir Bitton Renovations & Additions
2 North Forest Beach DR #101 CFB
Hilton Head Island, SC 29928 Permit Number 2024-082101
Dear: Mr. Mintz & Bitton:
Thank you for your submission for architectural review for roof covering for your existing outdoor
dining terraces. We have reviewed your request for construction at the above location. This review and
approval is based upon the following:
1) Our review is based upon the documents, drawings and narratives submitted to us.
Application dated, August 21, 2024 and drawings dated August 13, 2024 along with your
plan narrative and renderings
2) Building setbacks from property are per LMO.
3) Tree removal based upon the site plan is approved, subject to the required approval and
mitigation by the Town of Hilton Head Island.
4) No construction, vertical, subterranean or otherwise, may be placed within any building
setback or buffer. This includes, but is not limited to, the following: Service yards,
HVAC equipment, above ground LPG storage tanks, storage yards, refuse receptacles,
satellite dish/antenna, vehicle parking, decking or patios, hardscape materials or material
of a non-pervious nature (e.g. cement walkways or driveways).
5) No exterior lighting, other than that shown on the submitted plans, is approved.
Any changes/additions/modifications to the submitted and approved plans will be required to be
submitted to the FBOA ARB for review and approval before construction of the
change/addition/modification is begun. Failure to do so may result in a covenant violation. Items not
shown on the submitted plans are not reviewed or approved and must be submitted with the final plans
to be reviewed for approval.
Please make a note of any additional items that we require above. Failure to submit the requested
documents for review prior to the start of construction may result in a covenant violation.
Page 17 of 64
We must be notified, in writing, upon completion of the project. Assuming no discrepancies between
the approved work and the inspected, finished project, we will conduct a final inspection and close our
files on this project.
We have emailed a copy of your approval to the Town and contractor for their records as well as
enclosing your ARB Building Permit. We request that the permit be posted at the site during
construction alongside the Town of Hilton Head Island Building Permit. Please provide a copy of this
approval to your contractor upon selection and have posted on site during construction.
Thank you for your submission, and, please do not hesitate to contact us with any questions.
Sincerely,
John D. Snodgrass
John D. Snodgrass,
Executive Director
JDS:me
Encl.
Cc: Town of Hilton Head Island, PIC – Email
Tony Genovese – Email
DePauw Architects – Email
Town of Hilton Head Island, Natural Resources - Email
F750D0
Page 18 of 64
Page 19 of 64
Page 20 of 64
Page 21 of 64
Page 22 of 64
Page 23 of 64
Page 24 of 64
Page 25 of 64
Page 26 of 64
Page 27 of 64
Page 28 of 64
Page 29 of 64
Page 30 of 64
Page 31 of 64
Page 32 of 64
Page 33 of 64
Page 34 of 64
Page 35 of 64
Page 36 of 64
Page 37 of 64
Page 38 of 64
Page 39 of 64
Page 40 of 64
(843) 284-7848
www.depauw.studio
PO BOX 688
BLUFFTON, SC 29910
SHEET
PROJECT NO.
REVISIONS
© COPYRIGHT 2024 DePAUW ARCHITECTS LLC
THIS DRAWING IS THE PROPERTY OF THE
ARCHITECT AND IS NOT TO BE REPRODUCED IN
WHOLE OR IN PART BY ANY MEANS OR METHOD
WITHOUT THE EXPRESS WRITTEN CONSENT OF
THE ARCHITECT. ANY UNAUTHORIZED
REPRODUCTION OR REUSE OF THESE
DOCUMENTS WILL RESULT IN LEGAL ACTION.
PROJECT CONTACT
DATE
NOT FOR CONSTRUCTION
2411
EXISTING CONDITIONS
PHOTOS
9/30/24
AS102
FLATBREAD GRILL
2 N. FOREST BEACH DRIVE
UNIT #101
HILTON HEAD ISLAND, SC 29928
ISSUED FOR REVIEW
IMPROVEMENTS TO:
JAD
ID DESCRIPTION DATE
Page 41 of 64
Page 42 of 64
ZONING TABLE:
ZONING DISTRICT:
OVERLAY DISTRICT:
USE OF PROPERTY:
GROSS SITE ACRES:
NET SITE ACRES:
(GROSS ACRES - TIDAL WETLANDS)
DISTURBED ACREAGE:
EXISTING BUILDING SQUARE FOOTAGE:
PROPOSED BUILDING SQUARE FOOTAGE:
EXISTING PARKING:
TOTAL REQUIRED PARKING:
TOTAL ADDITIONAL PARKING:
EXPECTED NUMBER OF MONTHS TO COMPLETE PROJECT:
COLIGNY RESORT DISTRICT
CORRIDOR OVERLAY
RESTAURANT & MIXED COMMERCIAL USES
0.93 ACRES
0.93 ACRES
0.02 AC.
±15,750 SQ. FT.
±15,750 SQ. FT. (NO NEW CONDITIONED AREA ADDED)
70 SPACES
N/A (NO CHANGE IN OUTDOOR DINING AREA SIZE)
0 SPACES
3 MONTHS
FLOOD ZONE:
FIRM FLOOD ZONE:
BASE FLOOD ELEVATION:
DESIGN FLOOD ELEVATION:
AO (DEPTH 1 FT.) & X
N/A
N/A
SITE INFO:
TAX MAP & PARCEL NUMBER: R552 018 000 0012 0000
LOT COVERAGE:
EXISTING IMPERVIOUS AREA:
PROPOSED IMPERVIOUS AREA:
±33,332 SQ. FT.
±33,332 SQ. FT. (NO CHANGE)
SETBACK & BUFFER AREAS:
DO NOT APPLY TO THE AREA OF PROPOSED CONSTRUCTION.
(843) 284-7848
www.depauw.studio
PO BOX 688
BLUFFTON, SC 29910
SHEET
PROJECT NO.
REVISIONS
© COPYRIGHT 2024 DePAUW ARCHITECTS LLC
THIS DRAWING IS THE PROPERTY OF THE
ARCHITECT AND IS NOT TO BE REPRODUCED IN
WHOLE OR IN PART BY ANY MEANS OR METHOD
WITHOUT THE EXPRESS WRITTEN CONSENT OF
THE ARCHITECT. ANY UNAUTHORIZED
REPRODUCTION OR REUSE OF THESE
DOCUMENTS WILL RESULT IN LEGAL ACTION.
PROJECT CONTACT
DATE
NOT FOR CONSTRUCTION
2411
COVER SHEET
9/30/24
A001 FLATBREAD GRILL
2 N. FOREST BEACH DRIVE
UNIT #101
HILTON HEAD ISLAND, SC 29928
ISSUED FOR REVIEW
FLATBREAD GRILL
ISSUED FOR REVIEW
IMPROVEMENTS TO:
JAD
2 N. FOREST BEACH DRIVE, UNIT #101, HILTON HEAD ISLAND, SC 29928
DRAWING INDEX:
SHEET # SHEET NAME
A001 COVER SHEET
__ PLAT
AS101 SITE DEVELOPMENT PLAN
AS102 EXISTING CONDITIONS PHOTOS
AD101 DEMOLITION PLANS
A102 FIRST FLOOR PLAN
A103 ROOF PLAN
A201 ELEVATIONS
A202 ELEVATIONS
A203 MASSING MODEL
AE101 LIGHTING PLAN
ABBREVIATIONS:
AB ANCHOR BOLT
ABV ABOVE
AFF ABOVE FINISH FLOOR
ASF ABOVE SUB-FLOOR
A/C AIR CONDITIONER
AHU AIR HANDLING UNIT
ALUM ALUMINUM
AMSL ABOVE MEAN SEA LEVEL
APPROX APPROXIMATE
BD BOARD
BF BI-FOLD
BLKG BLOCKING
BLDG BUILDING
B.O. BOTTOM OF
BOD BASIS OF DESIGN
BRG BEARING
BTW BETWEEN
CAB CABINET
CANT CANTILEVER
CEN CENTER
CIP CAST-IN-PLACE
CJ CEILING JOIST
CL CENTERLINE
CLOS CLOSET
CLG CEILING
CM CASEMENT
CO CASED OPENING
COL COLUMN
CONC CONCRETE
CT CERAMIC TILE
DBL DOUBLE
DEMO DEMOLISH
DH DOUBLE HUNG
DIA DIAMETER
DIM DIMENSION
DIST DISTANCE
DN DOWN
DR DOOR
DW DISHWASHER
DWG DRAWING
EA EACH
ELEV ELEVATION
ELEC ELECTRICAL
EQ EQUAL
EQUIP EQUIPMENT
EXST EXISTING
EXT EXTERIOR
FD FLOOR DRAIN
FDN FOUNDATION
FDTN FOUNDATION
FF FINISH FLOOR
FFE FINISH FLOOR
ELEVATION
FIN FINISH
FIX FIXTURE
FIXT FIXTURE
FLUOR FLUORESCENT
FLR FLOOR
FRZ FREEZER
FRMG FRAMING
FT FEET
FTG FOOTING
GA GAUGE
GALV GALVANIZE
GL GLASS
GYP GYPSUM
GWB GYPSUM WALL BOARD
HB HOSE BIBB
HDR HEADER
HORIZ HORIZONTAL
HT HEIGHT
I.D. INSIDE DIMENSION
IN INCH
INCL INCLUDE
INSUL INSULATION
INT INTERIOR
JST JOIST
JNT JOINT
KS KNEE SPACE
VICINITY MAP:
PROJECT TEAM:
DISCIPLINE NAME LICENSE: PHONE NO:
ARCHITECT DePAUW ARCHITECTS 101932 (843) 284-7848
LANDSCAPE --- --- ---
STRUCTURAL --- --- ---
BUILDING CODES:
(ALL CODES W/ SOUTH CAROLINA MODIFICATIONS)
INTERNATIONAL BUILDING CODE:
INTERNATIONAL FIRE CODE:
INTERNATIONAL PLUMBING CODE:
INTERNATIONAL MECHANCIAL CODE:
INTERNATIONAL FUEL-GAS CODE:
INTERNATIONAL EXISTING BUILDING CODE:
INTERNATIONAL ENERGY CONSERVATION CODE:
NATIONAL ELECTRICAL CODE:
2021
2021
2021
2021
2021
2021
2021
2020 (NFPA 70)
DESCRIPTION OF WORK
ADDITION OF A PORCH ROOF OVER AN EXISTING OPEN DECK.
OCCUPANCY & CONSTRUCTION:
OCCUPANCY CLASSIFICATION:
OCCUPANT LOAD:
CONSTRUCTION:
SPRINKLERED/NON:
(IBC §903) •
ASSEMBLY (A-2)
TYPE V-B (UNCHANGED)
AUTO. SPRINKLER SYSTEM EXISTING
DRY HEADS TO BE ADDED TO WET SYSTEM
THROUGH EXTERIOR WALL OF RESTAURANT
NOTES:
NOTICE TO PERMITTING AUTHORITY & BUILDING OWNER
REGARDING CONSTRUCTION ADMINISTRATION SERVICES:
THE SEALING ARCHITECT AND THE FIRM OF RECORD HAVE NOT BEEN ENGAGED
TO PERFORM THE MINIMUM CONSTRUCTION ADMINISTRATION SERVICES, AS
DEFINED IN SC CODE OF REGULATIONS CHAPTER 11-12.B(5).
ARCHITECT OF RECORD IS NOT RESPONSIBLE FOR INTERPRETING THE INTENT OF
THE CONSTRUCTION DOCUMENTS INCLUDING MAKING MODIFICATIONS AS MAY
BE NECESSARY DURING THE CONSTRUCTION PHASE; AND THE ARCHITECT OF
RECORD IS NO LONGER LIABLE FOR THE WORK WHERE CHANGES TO THESE
DOCUMENTS HAVE BEEN MADE.
LAM LAMINATE
LL LIVE LOAD
LT LIGHT
LIN LINEN
MA MASONRY
MAS MASONRY
MAX MAXIMUM
MECH MECHANICAL
MED MEDIUM
MFR MANUFACTURER
MID MIDDLE
MIN MINIMUM
MISC MISCELLANEOUS
MUL MULLION
N/A NOT APPLICABLE
N.I.C. NOT IN CONTRACT
NTS NOT TO SCALE
OC ON CENTER
OD OUTSIDE DIMENSION
OH OVERHANG
OPNG OPENING
OSB ORIENTED STRAND BOARD
PAF POWER-ACTUATED FASTENER
PDE POP-UP DRAIN EMITTER
PEMB PRE-ENGINEERED METAL BLDG
PL PLATE
PNL PANEL
PNT PAINT
PMEJ PRE-MOULDED
EXPANSION JOINT
PR PAIR
PT PRESSURE TREATED
PVC POLYVINLYCHLORIDE
PVMT PAVEMENT
PLY PLYWOOD
PWDR POWDER ROOM
R RADIUS
R & S ROD & SHELF
RAG RETURN AIR GRILL
REF REFRIGERATOR
REQ'D REQUIRED
RM ROOM
RV RIDGE VENT
SAF SELF-ADHERED FLASHING
SCHED SCHEDULE
SECT SECTION
SF SQUARE FEET
SH SHELF
SIM SIMILAR
SND SANITARY NAPKIN DISPENSER
SPEC SPECIFICATION
SF SQUARE FEET
STD STANDARD
STL STEEL
STOR STORAGE
SYS SYSTEM
T TREAD
T.O. TOP OF
TR TREATED
T & G TONGUE & GROOVE
TEL TELEPHONE
TEMP TEMPORARY/
TEMPERATURE
THK THICK
TV TELEVISION
TPH TOILET PAPER HOLDER
TYP TYPICAL
UC UNDER-COUNTER
UNFIN UNFINISHED
U.N.O. UNLESS NOTED OTHERWISE
U.O.N. UNLESS OTHERWISE NOTED
VB VAPOR BARRIER
VER VERIFY
V.I.F. VERIFY IN FIELD
VERT VERTICAL
WD WOOD
W/D WASHER-DRYER
WH WATER HEATER
CODE ANALYSIS:
PROJECT
SITE
ID DESCRIPTION DATE
Page 43 of 64
Page 44 of 64
DN
EXISTING
FLATBREAD GRILL RESTAURANT
EXISTING
FABRIC AWNING
AREA
EXISTINGBAR WINDOW
EXISTING
PORCH
EXISTING
TRELLIS AREA(APPROXIMATE)
SCOPE OF
WORK
25'-0" ADJACENT USE SETBACK
(ALL OTHER RESIDENTIAL)
25'-0" ADJACENT USE SETBACK
(ALL OTHER RESIDENTIAL)
30'-0"/60° ADJACENT STREET SETBACK (CR DISTRICT)
NO SETBACKS
NO BUFFERS
14" LO
7 5
2
1
4
8
9
3
APPROX. LOCATION OF 14"
LIVE OAK TO BE REMOVED
(MEASURED 5/15/24)
AREA OF DECK TO BE
ROOFED (544 SQ. FT.)
(UNIT 101)
UNIT 103
NOTE: EXISTING GRADING TO
REMAIN SURROUNDING ALL
PROPOSED IMPROVEMENTS
±470 SF
±2,360 SF
±12,910 SF
(2) NEW LIVE OAKS (QUERCUS
VIRGINIANA) 10' MIN. HT., 2" MIN. TRUNK
DIAMETER @ TIME OF PLANTING
TREE PROTECTION FOR
TREES WITHIN 25' OF
CONSTRUCTION, TYP.
FIELD VERIFY LOCATIONS
(SEE 2/AS101)
ZONING TABLE:
ZONING DISTRICT:
OVERLAY DISTRICT:
USE OF PROPERTY:
GROSS SITE ACRES:
NET SITE ACRES:
(GROSS ACRES - TIDAL WETLANDS)
DISTURBED ACREAGE:
EXISTING BUILDING SQUARE FOOTAGE:
PROPOSED BUILDING SQUARE FOOTAGE:
EXISTING PARKING:
TOTAL REQUIRED PARKING:
TOTAL ADDITIONAL PARKING:
EXPECTED NUMBER OF MONTHS TO COMPLETE PROJECT:
COLIGNY RESORT DISTRICT
CORRIDOR OVERLAY
RESTAURANT & MIXED COMMERCIAL USES
0.93 ACRES
0.93 ACRES
0.02 AC.
±15,750 SQ. FT.
±15,750 SQ. FT. (NO NEW CONDITIONED AREA ADDED)
70 SPACES
N/A (NO CHANGE IN OUTDOOR DINING AREA SIZE)
0 SPACES
3 MONTHS
FLOOD ZONE:
FIRM FLOOD ZONE:
BASE FLOOD ELEVATION:
DESIGN FLOOD ELEVATION:
AO (DEPTH 1 FT.) & X
N/A
N/A
SITE INFO:
TAX MAP & PARCEL NUMBER: R552 018 000 0012 0000
LOT COVERAGE:
EXISTING IMPERVIOUS AREA:
PROPOSED IMPERVIOUS AREA:
±33,332 SQ. FT.
±33,332 SQ. FT. (NO CHANGE)
SETBACK & BUFFER AREAS:
DO NOT APPLY TO THE AREA OF PROPOSED CONSTRUCTION. TREES TO BE REMOVED
CATEGORY 1
LIVE OAK 14"
DBH INCHES
14"
CATEGORY 2 DBH INCHES CATEGORY 3 DBH INCHES CATEGORY 4 DBH INCHES
TOTAL # TREES:
TOTAL DBH:
TOTAL # TREES:
TOTAL DBH:
TOTAL # TREES:
TOTAL DBH:
TOTAL # TREES:
TOTAL DBH:
1
14"
REPLACEMENT TREES
CATEGORY 1
LIVE OAK
DBH INCHES
2" MIN.
CATEGORY 2 DBH INCHES CATEGORY 3 DBH INCHES CATEGORY 4 DBH INCHES
TOTAL # TREES:
TOTAL DBH:
TOTAL # TREES:
TOTAL DBH:
TOTAL # TREES:
TOTAL DBH:
TOTAL # TREES:
TOTAL DBH:
2
4" MIN.
LIVE OAK 2" MIN.
4'-0"
ATTACH SIGN
TO POST
NOTES:
1. NO PRUNING SHALL BE PERFORMED EXCEPT
BY APPROVED ARBORIST
2. NO EQUIPMENT SHALL OPERATE INSIDE THE
PROTECTIVE FENCING INCLUDING DURING
FENCE INSTALLATION AND REMOCAL.
3. NO MATERIAL TO BE STORED WITHIN THE
TREE PROTECTION FENCE.
4. SEE SITE PLAN FOR LOCATION.
5. TREE PROTECTION FENCING SHALL BE
MAINTAINED THROUGHOUT THE DURATION
OF THE PROJECT. FENCE MUST REMAIN
UPRIGHT AND SLACK FREE.
6. WARNING SIGNS ARE TO BE MADE OF
DURABLE WATERPROOF MATERIAL. 24" x 24"
MINIMUM SIZE AND VISIBLE FROM BOTH
SIDES OF THE FENCE
TREE PROTECTION FENCE: ORANGE UV
RESISTANT HIGH-TENSILE STRENGTH
POLYETHYLENE LAMINAR BARRICADE FABRIC
1.33 LBS/LF STEEL POST @ 6'-0" O.C.
6" THK. LAYER OF MULCH W/IN FENCE
MAINTAIN EXISTING GRADE W/IN THE TREE
PROTECTOIN FENCE U.N.O.
(843) 284-7848
www.depauw.studio
PO BOX 688
BLUFFTON, SC 29910
SHEET
PROJECT NO.
REVISIONS
© COPYRIGHT 2024 DePAUW ARCHITECTS LLC
THIS DRAWING IS THE PROPERTY OF THE
ARCHITECT AND IS NOT TO BE REPRODUCED IN
WHOLE OR IN PART BY ANY MEANS OR METHOD
WITHOUT THE EXPRESS WRITTEN CONSENT OF
THE ARCHITECT. ANY UNAUTHORIZED
REPRODUCTION OR REUSE OF THESE
DOCUMENTS WILL RESULT IN LEGAL ACTION.
PROJECT CONTACT
DATE
NOT FOR CONSTRUCTION
2411
SITE DEVELOPMENT PLAN
9/30/24
AS101
FLATBREAD GRILL
2 N. FOREST BEACH DRIVE
UNIT #101
HILTON HEAD ISLAND, SC 29928
ISSUED FOR REVIEW
IMPROVEMENTS TO:
JAD
1/16" = 1'-0"AS101
1 SITE PLAN
ID DESCRIPTION DATE
1/4" = 1'-0"AS101
2 TREE PROTECTION
Page 45 of 64
(843) 284-7848
www.depauw.studio
PO BOX 688
BLUFFTON, SC 29910
SHEET
PROJECT NO.
REVISIONS
© COPYRIGHT 2024 DePAUW ARCHITECTS LLC
THIS DRAWING IS THE PROPERTY OF THE
ARCHITECT AND IS NOT TO BE REPRODUCED IN
WHOLE OR IN PART BY ANY MEANS OR METHOD
WITHOUT THE EXPRESS WRITTEN CONSENT OF
THE ARCHITECT. ANY UNAUTHORIZED
REPRODUCTION OR REUSE OF THESE
DOCUMENTS WILL RESULT IN LEGAL ACTION.
PROJECT CONTACT
DATE
NOT FOR CONSTRUCTION
2411
EXISTING CONDITIONS
PHOTOS
9/30/24
AS102
FLATBREAD GRILL
2 N. FOREST BEACH DRIVE
UNIT #101
HILTON HEAD ISLAND, SC 29928
ISSUED FOR REVIEW
IMPROVEMENTS TO:
JAD
ID DESCRIPTION DATE
Page 46 of 64
A201
2
A201
4
A201
1
A201
3
EXISTING
FLATBREAD GRILL RESTAURANT
EXISTING
FABRIC AWNING AREA
EXISTINGBAR WINDOW
EXISTINGCOVERED PORCH
EXISTING
COVERED TRELLIS AREA
(APPROXIMATE)
CONCRETE DECK
WOOD DECK
TOPS OF POST TO BE
REMOVED @ CHAMFER, TYP.
A001
1
(TRELLIS TO REMAIN)
6" / 12"
6" / 12"
6" / 12"
6" / 12"
6" / 12"
6" / 12"
6" / 12"
6" / 12"
EXISTING STANDING
SEAM METAL ROOFING
EXISTING
COVERED TRELLIS AREA
(APPROXIMATE)
(TRELLIS TO REMAIN)
(843) 284-7848
www.depauw.studio
PO BOX 688
BLUFFTON, SC 29910
SHEET
PROJECT NO.
REVISIONS
© COPYRIGHT 2024 DePAUW ARCHITECTS LLC
THIS DRAWING IS THE PROPERTY OF THE
ARCHITECT AND IS NOT TO BE REPRODUCED IN
WHOLE OR IN PART BY ANY MEANS OR METHOD
WITHOUT THE EXPRESS WRITTEN CONSENT OF
THE ARCHITECT. ANY UNAUTHORIZED
REPRODUCTION OR REUSE OF THESE
DOCUMENTS WILL RESULT IN LEGAL ACTION.
PROJECT CONTACT
DATE
NOT FOR CONSTRUCTION
2411
DEMOLITION PLANS
9/30/24
AD101
FLATBREAD GRILL
2 N. FOREST BEACH DRIVE
UNIT #101
HILTON HEAD ISLAND, SC 29928
ISSUED FOR REVIEW
IMPROVEMENTS TO:
JAD
1/8" = 1'-0"AD101
1 DEMOLITION FLOOR PLAN
1/8" = 1'-0"AD101
2 EXISTING ROOF PLAN
ID DESCRIPTION DATE
Page 47 of 64
DN
A201
2
A201
4
INTERNAL ORIGIN
A202
2
EXISTING
FLATBREAD GRILL RESTAURANT
EXISTING
FABRIC AWNING AREA
EXISTINGBAR WINDOW
EXISTINGCOVERED PORCH
EXISTING
COVERED TRELLIS AREA
(APPROXIMATE)
BEAM ABOVE FOR NEW
ROOF STRUCTURE, TYP.
BEAM ABOVE FOR NEW
ROOF STRUCTURE, TYP.
NEW COVERED PORCH AREA
EXISTING POSTS TO BE
EXTENDED TO SUPPORT
NEW ROOF STRUCTURE
3
A202
_______
CONCRETE DECK
WOOD DECK
(TRELLIS TO REMAIN)
(843) 284-7848
www.depauw.studio
PO BOX 688
BLUFFTON, SC 29910
SHEET
PROJECT NO.
REVISIONS
© COPYRIGHT 2024 DePAUW ARCHITECTS LLC
THIS DRAWING IS THE PROPERTY OF THE
ARCHITECT AND IS NOT TO BE REPRODUCED IN
WHOLE OR IN PART BY ANY MEANS OR METHOD
WITHOUT THE EXPRESS WRITTEN CONSENT OF
THE ARCHITECT. ANY UNAUTHORIZED
REPRODUCTION OR REUSE OF THESE
DOCUMENTS WILL RESULT IN LEGAL ACTION.
PROJECT CONTACT
DATE
NOT FOR CONSTRUCTION
2411
FIRST FLOOR PLAN
9/30/24
A102 FLATBREAD GRILL
2 N. FOREST BEACH DRIVE
UNIT #101
HILTON HEAD ISLAND, SC 29928
ISSUED FOR REVIEW
IMPROVEMENTS TO:
JAD
1/4" = 1'-0"A102
1 RENOVATED FLOOR PLAN
ID DESCRIPTION DATE
Page 48 of 64
A201
2
A201
4
A202
2
6" / 12"
6" / 12"
6" / 12"
6" / 12"
6" / 12"
6" / 12"
1" / 12"
1" / 12"
1" / 12"
1" / 12" GALV. 6" HALF-ROUND GUTTER
DOWNSPOUT W/ RAINCHAIN
3
A202
_______
EXISTING
COVERED TRELLIS AREA
(APPROXIMATE)
(TRELLIS TO REMAIN)
(843) 284-7848
www.depauw.studio
PO BOX 688
BLUFFTON, SC 29910
SHEET
PROJECT NO.
REVISIONS
© COPYRIGHT 2024 DePAUW ARCHITECTS LLC
THIS DRAWING IS THE PROPERTY OF THE
ARCHITECT AND IS NOT TO BE REPRODUCED IN
WHOLE OR IN PART BY ANY MEANS OR METHOD
WITHOUT THE EXPRESS WRITTEN CONSENT OF
THE ARCHITECT. ANY UNAUTHORIZED
REPRODUCTION OR REUSE OF THESE
DOCUMENTS WILL RESULT IN LEGAL ACTION.
PROJECT CONTACT
DATE
NOT FOR CONSTRUCTION
2411
ROOF PLAN
9/30/24
A103 FLATBREAD GRILL
2 N. FOREST BEACH DRIVE
UNIT #101
HILTON HEAD ISLAND, SC 29928
ISSUED FOR REVIEW
IMPROVEMENTS TO:
JAD
1/4" = 1'-0"A103
1 RENOVATED ROOF PLAN
ID DESCRIPTION DATE
Page 49 of 64
FIRST FLOOR
13'-1" AMSL
ROOF BEARING
25'-1" AMSL
GRADE
8'-1" AMSL
B.O. EXISTING BEAM
22'-2" AMSL
B.O. BEAM
REMOVE TOP OF EXISTING POST
@ CHAMFER AT INDICATED
LOCATIONS
REMOVE AWNING POST (AWNING
MODIFICATIONS BY OTHERS TO MOUNT
TO SIDE OF NEW CONSTRUCTION)
3
A202
_______
FIRST FLOOR
13'-1" AMSL
ROOF BEARING
25'-1" AMSL
GRADE
8'-1" AMSL
B.O. BEAM
GALV. KNIFE PLATE CONNECTION
W/ STRAPPING DETAIL
TR. 6x6 POST TO
EXTEND EXISTING
TR. 3x8 EXPOSED RAFTERS
STANDING SEAM
METAL ROOFING TO
MATCH EXISTING
EXISTING ATTIC VENT LOUVERS
& SIGNAGE TO REMAIN
EXISTING RAILING & DECK
STRUCTURE TO REMAIN
GALV. 6" HALF-ROUND GUTTER
W/ DOWNSPOUT & RAINCHAIN
RAINCHAIN TO 2'x2'x4'
GRAVEL DRYWELL
3
A202
_______
6"
12"
FIRST FLOOR
13'-1" AMSL
ROOF BEARING
25'-1" AMSL
GRADE
8'-1" AMSL
B.O. EXISTING BEAM
22'-2" AMSL
B.O. BEAM
REMOVE TOP OF EXISTING POST
@ CHAMFER AT INDICATED
LOCATIONS
FIRST FLOOR
13'-1" AMSL
ROOF BEARING
25'-1" AMSL
GRADE
8'-1" AMSL
B.O. BEAM
GALV. KNIFE PLATE CONNECTION
W/ STRAPPING DETAIL
TR. 6x6 POST TO
EXTEND EXISTING
TR. 3x8 EXPOSED RAFTERS
STANDING SEAM
METAL ROOFING TO
MATCH EXISTING
EXISTING RAILING & DECK
STRUCTURE TO REMAIN
GALV. 6" HALF-ROUND GUTTER
W/ DOWNSPOUT & RAINCHAIN1"
12"
(843) 284-7848
www.depauw.studio
PO BOX 688
BLUFFTON, SC 29910
SHEET
PROJECT NO.
REVISIONS
© COPYRIGHT 2024 DePAUW ARCHITECTS LLC
THIS DRAWING IS THE PROPERTY OF THE
ARCHITECT AND IS NOT TO BE REPRODUCED IN
WHOLE OR IN PART BY ANY MEANS OR METHOD
WITHOUT THE EXPRESS WRITTEN CONSENT OF
THE ARCHITECT. ANY UNAUTHORIZED
REPRODUCTION OR REUSE OF THESE
DOCUMENTS WILL RESULT IN LEGAL ACTION.
PROJECT CONTACT
DATE
NOT FOR CONSTRUCTION
2411
ELEVATIONS
9/30/24
A201 FLATBREAD GRILL
2 N. FOREST BEACH DRIVE
UNIT #101
HILTON HEAD ISLAND, SC 29928
ISSUED FOR REVIEW
IMPROVEMENTS TO:
JAD
1/4" = 1'-0"A201
1 DEMO FRONT ELEVATION
1/4" = 1'-0"A201
2 RENOVATED FRONT ELEVATION
1/4" = 1'-0"A201
3 DEMO LEFT ELEVATION
1/4" = 1'-0"A201
4 RENOVATED LEFT ELEVATION
ID DESCRIPTION DATE
Page 50 of 64
FIRST FLOOR
13'-1" AMSL
ROOF BEARING
25'-1" AMSL
GRADE
8'-1" AMSL
B.O. EXISTING BEAM
22'-2" AMSL
B.O. BEAM
REMOVE TOP OF EXISTING
POST @ CHAMFER AT
INDICATED LOCATIONS
REMOVE AWNING POST (AWNING
MODIFICATIONS BY OTHERS TO MOUNT
TO SIDE OF NEW CONSTRUCTION)
FIRST FLOOR
13'-1" AMSL
ROOF BEARING
25'-1" AMSL
GRADE
8'-1" AMSL
B.O. BEAM
FIRST FLOOR
13'-1" AMSL
GRADE
8'-1" AMSL
B.O. BEAM
EXISTING HANDRAIL TO
REMAIN HIDDEN FOR CLARITY
FLAT STEEL PLATE ON KNIFE PLATE
@ T.O. EXISTING POST
BOLTED KNIFE PLATE CONNECTION
B/W EXISTING & NEW POSTS
BANDING TO RETAIN
EXISTING POST
TR. 4x10 BEAM
GALV. 6" HALF-ROUND GUTTER
(SEE ROOF PLAN FOR LOCATION)
TR. 3x8 EXPOSED RAFTER
(CUT TO MATCH TRELLIS)
T1-11 PORCH CEILING
ROOF SHEATHING
(SEE STRUCTURAL)
HIGH-TEMP ICE & WATER SHIELD
STANDING SEAM METAL ROOFING
TO MATCH EXISTING
DRIP EDGE FLASHING
TOE NAILED TIMBER SCREWS
FOR UPLIFT RESISTANCE
EXISTING DECK TO REMAIN
EXISTING 6x6 POST TO REMAIN
TR. 6x6 POST
96"
1"
12"
8'-0" AFF
R5"
(843) 284-7848
www.depauw.studio
PO BOX 688
BLUFFTON, SC 29910
SHEET
PROJECT NO.
REVISIONS
© COPYRIGHT 2024 DePAUW ARCHITECTS LLC
THIS DRAWING IS THE PROPERTY OF THE
ARCHITECT AND IS NOT TO BE REPRODUCED IN
WHOLE OR IN PART BY ANY MEANS OR METHOD
WITHOUT THE EXPRESS WRITTEN CONSENT OF
THE ARCHITECT. ANY UNAUTHORIZED
REPRODUCTION OR REUSE OF THESE
DOCUMENTS WILL RESULT IN LEGAL ACTION.
PROJECT CONTACT
DATE
NOT FOR CONSTRUCTION
2411
ELEVATIONS
9/30/24
A202
FLATBREAD GRILL
2 N. FOREST BEACH DRIVE
UNIT #101
HILTON HEAD ISLAND, SC 29928
ISSUED FOR REVIEW
IMPROVEMENTS TO:
JAD
1/4" = 1'-0"A202
1 DEMO RIGHT ELEVATION
1/4" = 1'-0"A202
2 RENOVATED RIGHT ELEVATION
1" = 1'-0"A202
3 COLUMN DETAIL
ID DESCRIPTION DATE
Page 51 of 64
(843) 284-7848
www.depauw.studio
PO BOX 688
BLUFFTON, SC 29910
SHEET
PROJECT NO.
REVISIONS
© COPYRIGHT 2024 DePAUW ARCHITECTS LLC
THIS DRAWING IS THE PROPERTY OF THE
ARCHITECT AND IS NOT TO BE REPRODUCED IN
WHOLE OR IN PART BY ANY MEANS OR METHOD
WITHOUT THE EXPRESS WRITTEN CONSENT OF
THE ARCHITECT. ANY UNAUTHORIZED
REPRODUCTION OR REUSE OF THESE
DOCUMENTS WILL RESULT IN LEGAL ACTION.
PROJECT CONTACT
DATE
NOT FOR CONSTRUCTION
2411
MASSING MODEL
9/30/24
A203
FLATBREAD GRILL
2 N. FOREST BEACH DRIVE
UNIT #101
HILTON HEAD ISLAND, SC 29928
ISSUED FOR REVIEW
IMPROVEMENTS TO:
JAD
ENTRY MASSING
RIGHT SIDE MASSING
ID DESCRIPTION DATE
Page 52 of 64
EX
EX
EX EXEX
EX
EX
HEATER
HEATER
HEATER
HEATER
HEATER
B
B
EXISTING LIGHTING TO REMAIN
C
A
A
A
A
AA
EXTERIOR LIGHTING SCHEDULE
MARK DESCRIPTION MANUFACTURER CATALOG NUMBER LAMP MOUNTING COLOR NOTES
A FAN W/ LIGHT KIT MINKA-AIRE F753L-CL 3000K LED CEILING COAL
B AIMABLE INFILL SPOT LIGHT B-K LIGHTING AR-LED-RM-X53-FL-BLP-9-11-A-3-WM WALL SATIN BLACK
C WALL SCONCE HUKORO 13.3"H MATTE BLACK OUTDOOR WALL LIGHT WALL BLACK
3000K LED
3000K LED
(843) 284-7848
www.depauw.studio
PO BOX 688
BLUFFTON, SC 29910
SHEET
PROJECT NO.
REVISIONS
© COPYRIGHT 2024 DePAUW ARCHITECTS LLC
THIS DRAWING IS THE PROPERTY OF THE
ARCHITECT AND IS NOT TO BE REPRODUCED IN
WHOLE OR IN PART BY ANY MEANS OR METHOD
WITHOUT THE EXPRESS WRITTEN CONSENT OF
THE ARCHITECT. ANY UNAUTHORIZED
REPRODUCTION OR REUSE OF THESE
DOCUMENTS WILL RESULT IN LEGAL ACTION.
PROJECT CONTACT
DATE
NOT FOR CONSTRUCTION
2411
LIGHTING PLAN
9/30/24
AE101
FLATBREAD GRILL
2 N. FOREST BEACH DRIVE
UNIT #101
HILTON HEAD ISLAND, SC 29928
ISSUED FOR REVIEW
IMPROVEMENTS TO:
JAD
1/4" = 1'-0"AE101
1 LIGHTING PLAN
ID DESCRIPTION DATE
Page 53 of 64
Image File Name: F753L-CL.jpg
Java - LED 54" Ceiling Fan
Item #: F753L-CL
UPC Code: 706411061936
Product Family Name: Java LED
Finish: Coal
Category: EXTERIOR FAN
Category Type: Ceiling Fan
Certification: E75795
Patents:
Notes:
LED
Wet Location
UL Listed
MEASUREMENTS
Blade Finish:
Blade Material: PC
Blade Sweep: 54"
No. of Blades: 3
Blade Pitch: 14 DEGREES
Reversible Blades: NO
Slope: YES
Hanging Weight: 17 .22
Downrod 1: 6
Downrod 1 Outside Dia: 0.75
Downroad 2:
Downrod 2 Outside Dia:
Ceiling to Lowest Point: (Dim A): 14.75
Ceiling to Blade (Dim B): 13.25
Lead Wire: 80"
Power: AC
Motor Size: AC 153 X 18mm
Low Low/Med. Medium Med/High High
RPM 79 156
Amps 0.218 0.391
Watts 14.51 47.27
CFM 2834.0 5771.0
CFM/Watts 195.31 122.09
LAMPING
No. of Bulbs: 1
Max Bulb Wattage: 18
Light Type: Z32 LED
Light Kit Optional: NO
Socket: Y30 LED MODULE
Integrated Light Kit: YES
Dimmable: YES
Ballast:
Rated Life Hours: 30000
Uplight: NO
Bulb/LED Included: YES
Color Temp.: 3000
CRI: 92
Initial Lumens: 1489.1
Delivered Lumens: 488.9
GLASS
Description: OPAL FROSTED
Material:
Part No.: GF753
Quantity: 1
Width: 7 .17
Height: 1.77
Length: 7 .17
CONTROLS
Pull Chain Control: NO
Works with Remote Control: YES
Works with Wall Control: YES
Reversible: YES
Included Remote Control: RCS213
Included Wall Control:
Smart Control: NO
Compatible Remote Control(s):
Compatible Wall Control(s): WCS213
Integrated Smart Control:
Compatible Smart Control: BD-1000
SHIPPING
Carton Width: 9.88
Carton Height: 10.5
Carton Length: 28.0
Carton Weight: 20.04
Carton Cubic Feet: 1.681
Small Package Shippable: YES
Master Pack Width:
Master Pack Height:
Master Pack Length:
Master Pack Weight:
Master Cubic Feet:
Multi-Pack: 1
Master Pack: 1
WARNING: Handling this product can expose you to chemicals including lead, which is known to the State of California to
cause cancer and birth defects or other reproductive harm. Wash hands with soap and water after installing, handling,
cleaning or otherwise touching this product. For more information go to: www.P65Warnings.ca.gov.
For additional information, please contact Customer Care: 1-800-221-7977 | Product depicted on this spec sheet is
protected by United States Federal and/or State laws including US Patent, Trademark and/or Copyright and unfair
competition laws. Unauthorized reproduction or use carries severe legal penalties.
Rev 01.10.2024 01:45 PM
TYPE A
Page 54 of 64
DATE :
CATALOG NUMBER LOGIC:
PROJECT: TYPE:
THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF B-K LIGHTING, INC. AND ITS RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE, DISCLOSE ITS CONTENTS, OR TO
MANUFACTURE, USE OR SELL ANYTHING IT MAY DESCRIBE. REPRODUCTION, DISCLOSURE OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF B-K LIGHTING, INC. IS STRICTLY FORBIDDEN.
559.438.5800 | INFO@BKLIGHTING.COM | BKLIGHTING.COMMADE IN THE USA
Driver housing required. Configure
separately.
ARTISTAR LED (REMOTE DRIVER)
CATALOG NUMBER LOGIC
Example: B - AR - LED - RM - x54 - FL - POL - 12 - 11 - B - 6 - WM
MATERIAL
(Blank) - Aluminum B - Brass S - Stainless Steel
SERIES
AR - ArtiStar
SOURCE
LED - Chip on Board Technology
HOUSING
RM - Remote Driver
LED TYPE
x52 - 10W LED/2700K x53 - 10W LED/3000K x54 - 10W LED/4000K
OPTICS
SP - Spot (20°) FL -Flood (40°) WFL - Wide Flood (60°)
FINISH (See page 2 for full-color swatches)
Standard Finishes (BZP, BZW, BLP, BLW, WHP, WHW, SAP, VER)
Premium Finish (ABP, AMG, AQW, BCM, BGE, BPP, CAP, CMG, CRM, HUG, NBP, OCP, RMG, SDS, SMG,
TXF, WCP, WIR)
Also available in RAL Finishes
Brass Finishes (MAC, POL, MIT)
Stainless Steel Finishes (MAC, POL)
LENS TYPE
9 - Clear (Standard) 12 - Soft Focus 13 - Rectilinear
SHIELDING
11 - Honeycomb Baffle
CAP STYLE
A - 45°
B - 90°
C - Flush
D - 45° Less Weephole (Interior use only)
E - 90° Less Weephole (Interior use only)
F - 90° with Flush Lens
BASE HEIGHT
3” (Standard), 6” , 12” , 18” , & 24” with Anchor Base
MOUNTING OPTIONS
PP - 18” Power Pipe Stake Mount
SF - Stability Flange (For use with Power Pipe)
WM - Wall or Ceiling Mount with 5” dia. Machined Canopy**
IP66 RATED
12/06/2022 SKU-1015
*Base height limited to 6” max. with Brass and
Stainless Steel Canopy.
SUB-2126-00
TYPE B
Page 55 of 64
DAT E : PROJECT: TYPE:
THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF B-K LIGHTING, INC. AND ITS RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE, DISCLOSE ITS CONTENTS, OR TO
MANUFACTURE, USE OR SELL ANYTHING IT MAY DESCRIBE. REPRODUCTION, DISCLOSURE OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF B-K LIGHTING, INC. IS STRICTLY FORBIDDEN.
559.438.5800 | INFO@BKLIGHTING.COM | BKLIGHTING.COMMADE IN THE USA
Satin Black
(BLP)
Satin Bronze
(BZP)
Satin White
(WHP)
Black Wrinkle
(BLW)
Bronze Wrinkle
(BZW)
White Wrinkle
(WHW)
Verde
(VER)
Satin Aluminum
(SAP)
Cascade Mtn.
Granite (CMG)
Black Chrome
(BCM)
Weathered Iron
(WIR)
Rocky Mtn.
Granite (RMG)
Beige (BGE)
Clear Anodized
Powder (CAP)
Sierra Mtn
Granite (SMG)
Weathered
Copper (WCP)
Antique Brass
Powder (ABP)
Cream
(CRM)
Aleutian Mtn
Granite (AMG)
Old Copper
(OCP)
Brown Patina
Powder (BPP)
Antique White
(AQW)
Textured Forest
(TXF)
Hunter Green
(HUG)
Sonoran Desert
Sandstone (SDS)
Natural Brass
Powder (NBP)
STANDARD FINISHES PREMIUM FINISHES
Click Here to view larger, full-color swatches of all
available finishes on our website.
C CAP F CAP
(38mm)
1 1/2”
(51mm)
2"
(114mm)
4 1/2"
3 1/8"
(79mm)
A/D CAP B/E CAP
2 3/8"
(60mm)
1"
(25mm)
1/8"
(3mm)
3"
(76mm)
4 1/2"
(114mm)
2 1/4" Dia.
(57mm)
6"
(152mm)
(610mm)
24"
18"
(457mm)
(305mm)
12"
2 1/4" Dia.
(57mm)
7/8 Dia.
(22mm)1 /4" Dia.
(6mm)
at 120°
STANDARD BASE
WALL MOUNT CANOPY
POWER PIPE
5/8”
(16mm)
3 1/2" O.C.
(89mm)
5" Dia.
(127mm)
3/8”
(10mm)
Stability
Flange
(Optional)
6" Dia
(152mm)
7/8" (22 mm)
18”
(457mm)
1"
(25mm)
ARTISTAR LED (REMOTE DRIVER) IP66 RATED
12/06/2022 SKU-1015
SUB-2126-00
TYPE B
Page 56 of 64
DATE : PROJECT: TYPE:
Accessories (Configure separately)
SPECIFICATIONS
THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF B-K LIGHTING, INC. AND ITS RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE, DISCLOSE ITS CONTENTS, OR TO
MANUFACTURE, USE OR SELL ANYTHING IT MAY DESCRIBE. REPRODUCTION, DISCLOSURE OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF B-K LIGHTING, INC. IS STRICTLY FORBIDDEN.
559.438.5800 | INFO@BKLIGHTING.COM | BKLIGHTING.COMMADE IN THE USA
ELECTRICAL
PHYSICAL
WAT TAGE 10W LED
WIRING Teflon® coated, 18AWG, 600V, 250° C rated and certified to UL 1659 standard.
REMOTE DRIVER For use with remote LED driver. See remote driver submittal to determine remote distance and wiring
requirements prior to detailing field installation of any remote wiring.
MATERIALS Furnished in copper-free aluminum (6061-T6), brass (360) or stainless steel (304).
BODY Unibody design with enclosed, water-proof wireway and integral heat sink is fully machined from solid billet.
KNUCKLE Aim & Lock knuckle is integral to the body and features an interior taper machined from solid billet and a
reverse angle taper allowing full 18° vertical adjustment without the use of aim-limiting serrated teeth. High
temperature, silicone ‘O’ Ring provides water-tight seal and compressive resistance to maintain fixture
position. Design withstands 73 lbs. static load prior to movement for optical alignment with a ½” pipe thread
for mounting. Optional 360SL provides biaxial source control with 360° horizontal rotation in addition to
vertical adjustment.
CAP Fully machined and accommodates two (2) lens or louver media.
LENS Shock-resistant, tempered glass lens is factory adhered to fixture cap and provides hermetically sealed
optical compartment.
LED Integrated solid state system and modular design with electrical disconnects allow for easy field upgrade
and maintenance. LM-80 certified. Minimum 50,000 hour rated life at 70% of initial lumens (L70). LED
technology provides long life, significant energy reduction and exceptional thermal management.
COLOR MANAGEMENT Corrected cold phosphor technology delivers natural white light with long term phosphor maintenance over
product life. Exact color point conformity exceeds ANSI C78.377 standard. Provides uniform beam with no
color variation over angle. Module exceeds 80 CRI (RA>80, R9>16).
INSTALLATION Available for installation in three distinct mounting conditions:
ANCHOR BASE (STANDARD) Machined anchor base with 7/8” dia. slip conduit hole and (3) 3/16” dia. anchor bolt holes (hardware by
others).
POWER PIPE (OPTIONAL) Provides a clean transition from wiring system to fixture. Schedule 80, 18” PVC housing for direct burial into
soil or concrete. Machined 2 1/4” dia. cap for fixture mounting with stainless steel hardware. Optional 6” dia.,
molded stability flange, to simplify installation and projects into substrate to reinforce housing stability.
WALL MOUNT CANOPY
(OPTIONAL)
Optional 5” dia. machined canopy permits mounting to junction box (gasket by others). 8” maximum base
height for canopy-mounted brass or stainless steel fixture.
OPTICS Interchangeable OPTIKIT modules permit optical field changes. Color-code: Narrow Spot (NSP) = red; Spot
(SP) = green; Medium Flood (MFL) = yellow; Wide Flood (WFL) = blue.
HARDWARE Tamper-resistant, stainless steel hardware. Knuckle vertical aiming screw is black oxide treated for
additional corrosion resistance.
FINISH StarGuard, our 15-stage chromate-free process cleans and conversion coats aluminum components prior to
application of Class ‘A’ TGIC polyester powder coating and is RoHS compliant. Powder coat or metal finish
options available for brass material and metal finish option only for stainless steel material.
WARRANTY 5-year limited warranty.
CERTIFICATION & LISTING ITL tested to IESNA LM-79. UL Listed. Certified to CAN/CSA/ANSI Standards. RoHS compliant. Suitable for
indoor or outdoor use, in wet locations, and for installation within 4’ of the ground. IP66 Rated. Made in the
USA with sustainable processes.
HP2RMHP2RM PM2DRM & PM2RMPM2DRM & PM2RM DRM & RMDRM & RM
ARTISTAR LED (REMOTE DRIVER) IP66 RATED
12/06/2022 SKU-1015
SUB-2126-00
TYPE B
Page 57 of 64
DAT E : PROJECT: TYPE:
THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF B-K LIGHTING, INC. AND ITS RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE, DISCLOSE ITS CONTENTS, OR TO
MANUFACTURE, USE OR SELL ANYTHING IT MAY DESCRIBE. REPRODUCTION, DISCLOSURE OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF B-K LIGHTING, INC. IS STRICTLY FORBIDDEN.
559.438.5800 | INFO@BKLIGHTING.COM | BKLIGHTING.COMMADE IN THE USA
LAMP & DRIVER DATA (x52, x53, x54)
LM79 DATA L70 DATA OPTICAL DATA
BK No. Lumens
(Source) CCT (Typ.) CRI (Ra.Typ.) Input Watts
(Tpy.)
Minimum Rated Life (hrs.)
70% of initial lumens (L70) Beam Type Angle CBCP
x52 1180 2700K 80 10 50,000 Spot 20° 2680
x53 1230 3000K 80 10 50,000 Flood 40° 1744
x54 1280 4000K 80 10 50,000 Wide Flood 60° 640
TYPE B
Page 58 of 64
TYPE C
Page 59 of 64
TYPE C
Page 60 of 64
1
DESIGNDESIGN TEAM/DRBTEAM/DRB COMMENTCOMMENT SHEETSHEET
TheThe commentscomments belowbelow areare staffstaff recommendationsrecommendations toto thethe DesignDesign ReviewReview BoardBoard (DRB)(DRB)
andand dodo NOTNOT constituteconstitute DRBDRB approvalapproval oror denial.denial.
PROJECT NAME: 2 North Forest Beach Drive, #101 – Flatbread Grill DRB-001353-2024
DATE: 10/22/2024 CATEGORY: Roof Addition
RECOMMENDATION: Approval Approval with Conditions Denial
APPLICATION MATERIAL
DRB REQUIREMENTS Complies
Yes No Not Applicable Comments or Conditions
Demolition Plan if needed
Existing Conditions match As-Built There is a section of roofing that was never approved
or received building permits for that is not part of this
proposal yet part of the roof plan. This area should be
address as well as the proposed roof addition.
Dimensioned Details and of Sections
Detail Illustrating Connection to Existing Structure
New Building Details Match Existing Building Details
ARCHITECTURAL DESIGN
DESIGN GUIDE/LMO CRITERIA Complies
Yes No Not Applicable Comments or Conditions
Structure is designed to be appropriate to the
neighborhood
Promotes pedestrian scale and circulation
Design is unobtrusive and set into the natural
environment
Utilizes natural materials and colors Provide a 11” x 17” material and color board.
Page 61 of 64
2
Avoids distinctive vernacular styles
Design is appropriate for its use
All facades shall have equal design characteristics
Avoids monotonous planes or unrelieved repetition
Has a strong roof form with enough variety to provide
visual interest
Overhangs are sufficient for the façade height.
Forms and details are sufficient to reduce the mass of the
structure
Human scale is achieved by the use of proper proportions
and architectural elements
Utilizes a variety of materials, textures and colors
Incorporates wood or wood simulating materials
Windows are in proportion to the facade
Details are clean, simple and appropriate while avoiding
excessive ornamentation
Utilities and equipment are concealed from view
Decorative lighting is limited and low wattage and adds
to the visual character
Accessory elements are designed to coordinate with the
primary structure
LANDSCAPE DESIGN
DESIGN GUIDE/LMO CRITERIA Complies
Yes No Not Applicable Comments or Conditions
Treats the Landscape as a major element of the project Provide existing and proposed landscape plan.
Provides Landscaping of a scope and size that is in
proportion to the scale of the development
Landscape is designed so that it may be maintained in
its natural shape and size
Preserves a variety of existing native trees and shrubs
Provides for a harmonious setting for the site’s
structures, parking areas or other construction
Location of existing trees and new trees provides
street buffers, mitigation for parking lots, and an
architectural complement that visually mitigates
between parking lots and building(s)
Shrubs are selected to complement the natural setting,
provide visual interest and screen less-desirable
elements of the project
Page 62 of 64
3
A variety of species is selected for texture and color
Provides overall order and continuity of the
Landscape plan
Native plants or plants that have historically been
prevalent on the Island are utilized
A variety of sizes is selected to create a “layered”
appearance for visual interest and a sense of depth
The location of existing mature trees is taken into
account in placement of shrubs so as not to damage
tree roots
Proper spacing and location for plants to reach their
mature size and natural shape while avoiding
excessive or unnatural pruning
Proposed groundcovers are evergreen species with
low maintenance needs
Large, grassed lawn areas encompassing a major
portion of the site are avoided
The adjacent development is taken into account in
determining the most appropriate buffer so as not to
depart too dramatically from the neighborhood
Ornamentals and Annuals are limited to entrances and
other focal points
NATURAL RESOURCE PROTECTION
DESIGN GUIDE/LMO CRITERIA Complies
Yes No Not Applicable Comments or Conditions
An effort has been made to preserve existing trees and
under story plants
Supplemental and replacement trees meet LMO
requirements for size, species and number
Wetlands if present are avoided and the required
buffers are maintained
Sand dunes if present are not disturbed
COMMENTS & CONDITIONS
1. Staff recommends approval of the conceptual design submittal with the following conditions:
a. Provide an existing and proposed landscape plan.
b. Provide a lighting plan.
c. Provide a 11” x 17” material and color board.
2. Any additional information as required by the Board.
Page 63 of 64
4
Page 64 of 64
Source: Town of Hilton Head Island website. First collected Nov 10, 2026.