RecordWell Data

_10222026-600

City of North Myrtle Beach · Horry County · meeting of Oct 22, 2026 · Minutes

Open the original document More from City of North Myrtle Beach

Text

Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.

TRC Minutes 10.22.26 Page 1 of 5 TECHNICAL REVIEW COMMITTEE MINUTES Thursday, October 22, 2026 – 10:00 A.M. Training Room/Zoom NEW APPLICATIONS CR-26-54: Courtesy Review– Seven Sleeping Area Single-Family at 614 21st Avenue North Attending Customer Representatives: Evan Rex, Applicant Staff Comments Public Works: 1. Since these units are considered 7 bedrooms, must meet city stormwater requirements, per city stormwater design manual. Must meet or exceed the 25 year –24-hour storm event if there is an available tie-in to an existing storm system. Must hold the 100 year – 24-hour storm event if no tie-in to existing system. 2. Will need to show a grading plan / stormwater plan with existing topo 3. Show existing services and call out meter sizes. Engineer to determine if existing meter size will be adequate. If not, call out the requested meter size. 4. Add SCDES approved backflow device at all water services if not one already in place. 5. Need to see details on the retaining walls. How tall, materials, specs, etc. 6. Any new retaining walls shall not block any existing storm drainage flow patterns from adjacent properties. 7. Max. 24’ wide driveway width within 21st Ave N. right-of-way. Can go to wider within the property line. 8. NPDES coverage letter or letter stating it is not necessary. May fall under automatic coverage. Fill out the “Less than 1 acre draining within ½ mile of Coastal Receiving Water” form. 9. Additional comments may be forthcoming pending further review or receipt of revised documents. Zoning: 10. No parking space shall have direct access to a street, and no vehicle shall extend into a public right-of-way. Each parking space shall be unobstructed and shall be so arranged that any vehicle may be moved into and out of such space without moving another vehicle. 11. Any room or space that provides privacy and separation from common living areas and could function as a sleeping space. Rooms labeled as offices, dens, bonus rooms, or similar shall be considered sleeping areas where the design includes features consistent with sleeping use, such as: Enclosure with walls and a door or defined separation or layout and dimensions consistent with habitable space. Building: No comments Fire: 12. What is the office use for? Is this all residential or mixed use? Planning: No comments TRC Minutes 10.22.26 Page 2 of 5 CR-26-53: Courtesy Review – East Coast Greenway Trail Head on Water Tower Road – PIN: 38902030001 Attending Customer Representatives: Eric Sanford, Applicant Staff Comments Public Works: 1. One of the handicap stalls will need to be Van Accessible. 2. Conceptually the layout is ok. Will need to see grading and drainage plans. 3. Additional comments may be forthcoming pending further review or receipt of revised documents. Zoning: No comments Building: No comments Fire: No comments Planning: 4. Not sure of the actual trail connection at this point; may make more sense to just take sidewalk to ROW, so the future connection can be made more easily. SUB-26-61: Major Final Subdivision Plat – Grande Dunes North Phase 6A Attending Customer Representatives: Cameron Parker, Engineer Staff Comments Public Works: No comments Zoning: No comments Building: No comments Fire: No comments Planning: 1. Change Barony Dr to match cover page (Sawyer Dr) if possible. 2. PIN 389-00-00-0235 owned by Meritage Homes. 3. Double check PB 334/61. 4. I'll put FG comments in the separate step as soon as they're available. SUB-26-62: Major Final Subdivision Plat – Grande Dunes North Phase 7A-1 Attending Customer Representatives: Cameron Parker, Engineer Staff Comments Public Works: No comments Zoning: No comments Building: No comments Fire: No comments Planning: 1. Change Barony Dr to match cover page (Sawyer Dr) if possible. 2. Double check PB 334/61. 3. Typo on lot 709 of Ph 7B, PB looks like 179 and it should be 17. TRC-26-32: Site-Specific Development Plan – 18th Avenue South Streetend Attending Customer Representatives: Cameron Parker, Engineer Staff Comments Public Works: 1. Revise sanitary sewer per your conversation with Ricky Bellamy. TRC Minutes 10.22.26 Page 3 of 5 2. Water service to restrooms shown from the wrong tie-in location. Use existing water service stub out. 3. Additional comments may be forthcoming pending further review or receipt of revised documents. Zoning: No comments Building: No comments Fire: No comments Planning: No comments TRC-26-23: Site-Specific Development Plan – Compass Resort at 1717 South Ocean Boulevard Attending Customer Representatives: Cameron Parker, Engineer Staff Comments Public Works: 1. Parking lot 3 has poor circulation and needs to be re-configured. Long dead end with no-turn around. Recommend removing an entrance from Perrin Dr. and relocating it to Holly Dr. so that it is aligned with 18th Ave S. intersection. 2. The single parking stall in parking lot #2 could potentially be blocked when a car parks in the adjacent space to the left. 3. Verify recommended throat lengths at all parking lot driveways per SCDOT ARMS manual Section 3B-4. 4. Verify compactor pad dimensions/appurtenances meets minimum city standards. 5. Provide sewer manhole at property line for sewer service line tie-in. 6. Provide SCDES approved backflow at the potable water meter. 7. Provide approved SCDOT encroachment permits prior to final site plan sign- off. Zoning: 8. Label parking lot interior landscape percentage on all the parking lots. 9. Provide lighting plan. 10. Shield all fixtures from residential property. 11. .5 maximum FC at residential property lines. 12. Lot 2. Provide curbing to protect landscaping. Trees less than 24" are not required to be saved. Any existing natural landscape character shall be preserved whenever possible, but curbing is required to protect landscaping. Lot 2 appears to have no curbing. 13. All required parking needs to be within 300 ft of the principal site. Lot 3 has 11 parking spaces that are either greater than 300 feet away. Historical zoning determinations were made that allowed incidental overflow of parking spaces when Sec. 23-41(5) was being implemented and further determined that noncontiguous off street required parking spaces are subject to the conditions specified in 23-41(5). 14. Provide parking requirement on front page, showing the number of rooms and bedroom count. I'm having trouble understanding the parking calculation. Hotel and time share should be combined. Please label number of units and bedroom counts. Double queen and king can be combined, their one-bedroom units. Ex. 98 one bedroom, 43 two bedroom. Please simplify. TRC Minutes 10.22.26 Page 4 of 5 Building: 15. Previous comment addressed. Fire: No comments Planning: No comments SUB-24-38: Major Preliminary Subdivision Plat – Creation of Right-of-Way through Farmhouse Tract off Atlantic Breeze Drive Attending Customer Representatives: Austin Graham, Engineer Staff Comments Public Works: No comments Zoning: No comments Building: No comments Fire: No comments Planning: 1. Show edge of gravel on preliminary plat. 2. On 11/10 PC agenda, please upload revised plat before next Wednesday 11/4. 3. Is this road private or public? Adjust label to reflect this. 4. Provide a street name. This will need to be reviewed by Dawn Snider to ensure the name is available. please email her a list. This will have to be sent to the county so please have this list sent to her beginning of the week. 5. Revise Pelican Bay Rd. to Atlantic Breeze Dr. 6. Include a site data table on the plat. TRC-26-28: Site-Specific Development Plan - 221 20th Avenue North Attending Customer Representatives: Terry Price, Applicant Staff Comments Public Works: 1. Showing dumpster on top of the water/sewer lines. Need to relocate. 2. Show storm profile for new alignment. 3. How will the building that was using the lot for a driveway access that unit with these changes? Show access driveway on plans. 4. New water line to match the size of the existing water line to be abandoned (6"). 5. Note on plans that waterline to be abandoned shall be capped at water main. 6. Additional comments may be forthcoming pending further review or receipt of revised documents. Zoning: 7. Previous comments: 8. Parking spaces shall not be stacked. 9. Each vehicle must be able to be backed up without moving another vehicle and must be able to back into a drive aisle before heading onto the street. 10. Can access easement be for 221 20th Ave. N. too? If so park 2 vehicles under rear of house and two vehicles under front of house possibly. If not possible. the "media" room can be altered to not be considered a sleeping area. 11. A sleeping area is any enclosed or semi-enclosed space within a dwelling unit that is designed or reasonably capable of functioning as a sleeping space based on its layout and physical characteristics at the time of plan review. Building: No comments TRC Minutes 10.22.26 Page 5 of 5 Fire: No comments Planning: No comments

Source: City of North Myrtle Beach website. First collected Nov 10, 2026.