agenda (opens in a new tab)
City of Cayce · Lexington County · Agendas
Open the original document More from City of Cayce
Text
Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.
1800 12th Street | PO Box 2004 | Cayce SC 29171
P 803 796 9020 | F 803 796 9072
caycesc.gov
Mayor
Elise Partin
Mayor Pro-Tem Council Members City Manager Assistant City Manager
James E. Jenkins Phil Carter Tracy Hegler
Ann Bailey-Robinson
Tim James
James E. Crosland
City of Cayce
Public Hearing and Regular Council Meeting
Wednesday, October 21, 2020 at 5:00 p.m.
Cayce City Hall is currently closed to the public.
Please use the following method to attend the Council Meeting:
Virtual Attendance, click
https://us02web.zoom.us/j/81908505265?pwd=SDZGclZ0dXdJeXBVaWJQbkZDWjFHZz09
or
Telephone: 1-929-205-6099
Meeting ID: 819 0850 5265
Passcode: 617506
caycesc.gov
PUBLIC HEARING ON THE ESTABLISHMENT OF A NEW FEE RELATED TO HOLDING A
SPECIAL EVENT IN THE CITY OF CAYCE AND NEW FEE AMOUNT
Special Note: Anyone wishing to speak at the Public Hearing will need to call the City
Clerk at 803-550-9557 by 11:00 a.m. the day of the Council Meeting. Please leave a
voicemail and your call will be returned before the Council Meeting.
I. Opening Statement
II. Public Testimony
III. Close Hearing
REGULAR COUNCIL MEETING
I. Call to Order
A. Invocation and Pledge of Allegiance
II. Public Comment Regarding Items on the Agenda
Special Note: Anyone wishing to speak to Council about an item not on the agenda will
need to call the City Clerk at 803-550-9557 by 12:00 p.m. the Friday prior to the Council
Meeting. Anyone wishing to speak on an item on the Agenda will need to call the City
Clerk at 803-550-9557 by 11:00 a.m. the day of the Council Meeting. Please leave a
voicemail and your call will be returned before the Council Meeting.
III. Presentations
A. Presentation of the Midlands Regional Competiveness Report by Mr. Will Schenk
IV. Resolutions and Ordinances
A. Approval of Resolution Supporting the City’s Safety Policy Statement
B. Discussion and Approval of Ordinance 2020-34 Amending Sec. 2-225 of the City
Code Concerning Attendance of Volunteer Members of City Boards,
Commissions and Committees – Second Reading
C. Discussion and Approval of Ordinance 2020-35 Amending the City Business
License Ordinance to Provide a Specific Business License Tax for Certain
Special Event Promoters – First Reading
V. Discussion Items
A. Discussion and Possible Action of Proposed Lexington County Stormwater Utility
Fee
B. Ratification and Approval of City Manager’s Authorization of Contingency
Change Order for Riverwalk Phase 2 Boardwalk Repair
C. Discussion and Approval to Convert all City Street Lights from High Intensity
Discharge (HID) to Light Emitting Diode (LED)
D. Discussion and Approval of Agreement with American Engineering and MR
Systems for Upgrades to the City’s Water Plant’s Supervisor Control and Data
Acquisition (SCADA) System
VI. Committee Matters
A. Appointments and Reappointments
Cayce Historical Museum Commission – One (1) Position
Cayce Municipal Election Commission – One (1) Position
VII. City Manager’s Report
VIII. Council Comments
IX. Executive Session
A. Receipt of legal advice relating to claims and potential claims by and against the
City and other matters covered by the attorney-client privilege
B. Receipt of legal advice and discussion of negotiations incident to proposed
contractual arrangements with Lexington County concerning inclusion of certain
property in Joint County Industrial Park
X. Reconvene
XI. Possible Actions by Council in follow up to Executive Session
XII. Adjourn
SPECIAL NOTE: Upon request, the City of Cayce will provide this document in
whatever form necessary for the physically challenged or impaired.
NOTICE OF PUBLIC HEARING ON THE ESTABLISHMENT OF A NEW
FEE AND FEE AMOUNT
Cayce City Hall is currently closed to the public.
Please use the following method to attend the Public Hearing and Council Meeting:
Date: October 21, 2020
Time: 5:00 p.m.
Telephone: 1 929-205-6099
Meeting ID: 819 0850 5265
Password: 617506
caycesc.gov
Notice is hereby given that members of Council of the City of Cayce will hold a Public
Hearing for the purpose of obtaining public comment on the establishment of a new fee
related to holding a special event in the City of Cayce:
One day:
On gross income up to $2,000….$50
On gross income between $2,001 and $10,000 ……$100
On gross income over $10,000:
Minimum on first $10,000…$200
$1,000, or fraction, over $10,000…$5.10
Two or more days:
Minimum on first $2,000…$200
$1,000, or fraction, over $2,000 ……$5.10
A listing of the new fee and fee amount is available for inspection at Cayce City Hall and
on the City website at www.caycesc.gov.
The new fee is for holding a special event in the City of Cayce.
The general public and other interested parties are encouraged to attend this public
hearing. Questions regarding this matter and/or review of documents relating to this
matter are available for public inspection in the City Manager’s Office, City of Cayce.
First reading and vote by the Council on the proposed fee will be held immediately
following the Public Hearing.
2019-20
Midlands Regional
Competitiveness Report
ITEM III. A. ITEM III. A.
Governed by the highest-ranking regional
leaders in education, government and business,
EngenuitySC is a nonprofit that works to make
the Columbia, S.C., region a standout choice for
top talent and competitive companies.
Structured as a neutral and independent project
management team, EngenuitySC is a trusted
force, working behind the scenes to build a
community cultivated for living, working,
playing and learning.
Our Mission
Our Vision
By 2030, the Columbia MSA will be one of the
Southeast’s most competitive and
prosperous metros - measured by being in
the top three of every index in the Midlands
Regional Competitiveness Report when
compared to our peers - propelled by
EngenuitySC projects and collaborations.
Platinum Sponsor
Gold Sponsors
Silver Sponsors
Bronze Sponsors
Aflac
Arnold Companies
BullStreet District
Central Carolina Community Foundation
City Center Partnership
Chernoff Newman
Colliers International | South Carolina
Greater Columbia Chamber of Commerce
First Citizens Bank
First Community Bank
Greater Lexington Chamber and
Visitors Center
John Lumpkin
Lexington Medical Center
LLE Construction
Nelson Mullins
SCRA
Synovus
The Cason Group
Public and Education Partners
Columbia, SC
MSA
Population: 832,666
Talent
Talent
● Our region’s largest business school, the UofSC Darla Moore School of
Business, just graduated its largest-ever class - 1,086 students, all
experienced in working with data and code
Share This
Pursue This
● Focus economic development efforts on attracting, building and
retaining skilled talent that fills industry needs outlined in the
Deloitte regional strategic planning initiative
Innovative Capacity
● The McNAIR Aerospace Center partners with global industry leaders
for cutting-edge research across multiple fields, including advanced
composites, predictive maintenance analytics and unmanned
vehicles
Share This
Pursue This
● Align regional and state economic development efforts by leveraging
existing strengths and relationships to attract research funding
from the Department of Defense in areas such as cybersecurity,
artificial intelligence and renewable energy
Entrepreneurial & Business
Environment
● Local company Diesel Laptops, a software and systems developer for
the logistics industry, has been an Inc. 5000 regular, growing 1,188%
in three years
Share This
Pursue This
● Using efforts like GrowCo, support building strong companies within
our region through services such as founder mentoring,
entrepreneur-focused regional marketing and talent attraction
Talent
Industry Clusters
● Our insurance cluster punches well above our region’s weight, with
an employment concentration that’s 345% the national average
Share This
Pursue This
● Take a coordinated approach to regional economic development by
aligning strategic plans to focus on industries in which we can
compete, such as financial and business services, biotech, aerospace
and medical device manufacturing
Livability
● Our outdoor recreation offerings can compete with any
community - with urban whitewater, S.C.’s only national park, one
of the nation’s largest urban green spaces, and over 600 miles of
shoreline on Lake Murray
Share This
Pursue This
● Connect communities and recreational assets by completing the
Three Rivers Greenway, linking Lake Murray and Lexington all the
way to downtown Columbia, Cayce and West Columbia
The Impact of COVID-19
● 12.1% unemployment and rising - largest-ever one-month increase1
● Hospitality & leisure, restaurants, retail, healthcare among hardest-hit
industries thus far2
● Columbia MSA lost 42,500 jobs (11.68% decrease) in April 20203, but
regained 12,100 in May 2020 as businesses began to reopen
● Lowest-paid workers and locally-owned businesses are vulnerable
● Remote work becoming the norm at large tech and professional
services companies
Now
Future
● Long-term economic impact will depend on length of disruption to
everyday life
● Local governments will see impacts from lost tax revenues
● Livability may become an increasing driver of success as places
compete for remote workers no longer tethered to major metros
● All opportunities to retrain and re-employ lower-wage workers
become even more critical
1. Since 1976, as tracked by SCDEW
2. U.S. Department of Labor
3. SCDEW weekly unemployment claims
ITEM IV. A.
STATE OF SOUTH CAROLINA )
)
C
OUNTY OF LEXINGTON )
)
CITY OF CAYCE )
)
ORDINANCE 2020-34
Amending Section 2 -225 of the City
Code Concerning Attendance of
Volunteer Members of City Boards,
Commissions and Committees
W
HEREAS, the Council believes it is in the public interest to change the
attendance requirements for volunteer members of City boards, commissions ,
committees, and foundations,
NO
W, THEREFORE, BE IT ORDAINED by the Mayor and Council of the City of
Cayce, in Council, duly assembled, that the sixth (next to last) sentence of Section 2-225
("Terms of members; removal of members; vacancies; service after expiration of term;
compensation") of Division 1 ('Generall y") of Article IV ("Boards, Commissions and
Committees") of Chapter 2 ("Administration") of the City Code is hereby amended and
replaced by new sentences six, seven, and eight, to read as follows:
In the event that any appointee to a committee misses one third of all
meetings of the committee to which the member has been appointed, within
a twelve (12) month period of service, the member shall be subject to removal
for cause by the Council . The chairman of the committee shall notify the
Mayor, in writing, when any member is absent a third of all meetings within
a twelve (12) month period of service. The C ouncil may, in its discretion,
waive enforcement of this provision in the case of illness, death of a family
member, c ourt appearance, or other similar circumstances beyond the
control of the member.
The current last sentence of Section 2-225 shall remain as the last sentence of the
Section.
T
his Ordinance shall become effective upon Council approval on second reading.
DO
NE IN MEETING DULY ASSEMBLED, this ______ day of _________2020.
______________________________
Elise Partin, Mayor
Attest:
___
___________________________
Mendy Corder, CMC, Municipal Clerk
F
irst Reading: _____________________
ITEM IV. B.
Second Reading and Adoption: ____________
Approved as to form: __________________________
Danny C. Crowe, City Attorney
Memorandum
T
o: Mayor and Council
F
rom: Tracy Hegler, City Manager
Carroll Williamson, Planning and Development Director
D
ate: October 15, 2020
S
ubject: Approval of an Ordinance to Amend the Business License Tax for Special Events to Create
New Fees for Smaller Events - First Reading
I
ssue
T
he City’s Business License Ordinance has a tax for special events, but it does not reflect the wide range
of special events that are held.
D
iscussion
T
he current business license tax has a tax for spec ial events, but it designed more for large events that
generate significant revenue or events that are held for more than one day. The new tax will be as
follows:
O
ne day:
On gross income up to $2,000 - $50
On gross income between $2,001 and $10,000 - $100
On gross income over $10,000:
Minimum on first $10,000 - $200
$1,000, or fraction, over $10,000 - $5.10
Tw
o or more days:
Minimum on first $2,000 - $200
$1,000, or fraction, over $2,000 - $5.10
T
his amendment will more appropriately license smaller events in the City that don’t generate as much
revenue as the larger events. For all special events, only the special events promoter will be required to
obtain a business license; no additional business license will be required for vendors at the event.
H
ospitality tax will still be required to be collected by all food and beverage vendors during an event.
Rec
ommendation
S
taff recommends Council approve the amendment to the Business License Ordinance to create new
fees for smaller events.
ITEM IV. C.
1
STATE OF SOUTH CAROLINA )
)
C
OUNTY OF LEXINGTON )
)
CITY OF CAYCE )
ORDINANCE 2020-35
Amending the City Business License
Ordinance to Provide a Specific
Business License Tax for Certain
Special Events Promoters
W
HEREAS, the Council has determined that is in the best interest of the City to
amend the business license tax for special event promoters that better captures the range
of different types of special events; and
W
HEREAS, the Business License Ordinance currently taxes all special events the
same, regardless of duration or amount of gross income generated,
NO
W, THEREFORE, BE IT ORDAINED by the Mayor and Council of the City of
Cayce, in Council, duly assembled, that the Class 8 Rates table and the descriptive listing
of Class 8 Rates in the City Business License Ordinance, also designated as Article II
("Licenses") of Chapter 12 ("Businesses") of the City Code, are hereby amended in
reference to promoters of Special Events to read as shown on the attached pages.
T
his Ordinance shall be effective from the date of second reading approval by Council.
DO
NE IN MEETING DULY ASSEMBLED, this ______ day of _________2020.
______________________________
Elise Partin, Mayor
Attest:
___
___________________________
Mendy Corder, CMC, Municipal Clerk
F
irst Reading: _____________________
S
econd Reading and Adoption: ____________
Approved as to form: __________________________
Danny C. Crowe, City Attorney
ITEM IV. C.
ITEM IV. C.
Memorandum
T
o: Mayor and Council
F
rom: Tracy Hegler, City Manager
Jim Crosland, Assistant City Manager
D
ate: October 21, 2020
S
ubject: Ratification and Approval of City Manager’s Authorization of Continency Change Order for
Riverwalk Phase 2 Boardwalk Repair
I
ssue
Co
uncil’s approval and ratification is needed for the City Manager’s authorization of a contingency
change order with 3D Dirtworks for additional concrete and rip rap to permanently stabilize the
boardwalk and assist with leveling.
D
iscussion
C
ity Administration requests that the Council approve and ratify the City Manager’s authorization on
October 19, 2020 to approve a change order in the amount of $10,000 by 3D Earthworks for the Cayce
Riverwalk Phase 2 Boardwalk Repair. City Council approved the original contract with 3D Dirtworks on
July 29, 2020. This additional work is for extra rip rap and concrete to be placed around the boardwalk
footings and fill large gaps where boulders had to be removed. This change order amount authorized by
the City Manager for this work would fall within the original amount of 20% contingency funding
provided by Council. The City Manager’s authorization for this change order is based on the
interpretation that the intent of a prior change order approved by Council was to provide additional
services within the amount of the original contingency, not necessarily from the contingency amount. A
time exigency factor considered in the City Manager’s authorization of this contingency was the City’s
interest in ensuring public safety by concluding the project’s repairs as expeditiously as possible before
the contractor moved on to non-City projects so as to reduce potential public safety hazards in the
project area.
Rec
ommendation
St
aff recommends that City Council approve and ratify the City Manager’s authorization on October 19,
2020 to approve a change order in the amount of $10,000 by 3D Earthworks for the Cayce Riverwalk
Phase 2 Boardwalk Repair.
ITEM V. B.
ITEM V. B.
Memorandum
T
o: Mayor and Council
F
rom: Tracy Hegler, City Manager
Jim Crosland, Assistant City Manager
D
ate: October 15, 2020
S
ubject: Dominion Conversion Program from HID to LED
I
ssue
C
ouncil’s approval is needed to authorize Dominion Energy to convert all street lighting in the City of
Cayce from HID (High Intensity Discharge) to LED (Light Emitting Diode).
D
iscussion
T
he City of Cayce has an opportunity through Dominion Energy to update all its old street lighting to
state-of-the-art lighting systems. The LED lighting is clearer, brighter, programmable, and lasts longer
than the HID systems. The monthly cost to operate is also lower. The lights, however, are more
expensive to purchase, adding to the monthly operating cost.
D
ominion Energy has an incentive program for municipalities that includes a ten-year contract with a
five-year incentive package. The total current monthly cost for LED is $12,698.67. The City currently pays
$10,475.46 per month for HID lighting. Dominion’s incentive is a monthly reduction of $2,957.26 which
means the City will save $744.05 per month off what we are currently paying, for the next five years.
After the five-year incentive program has expired under the ten-year contract, the City will be billed the
new LED rate which is decreasing every year and should be below the standard current City HID rate.
During the transition, we can also change out lighting systems around the City to better illuminate the
area and install uniformity.
Rec
ommendation
St
aff recommends that City Council approve the City Manager enter into a contract with Dominion
Energy to update all its City street lighting from HID to LED. This will include accepting the five-year
incentive package within the ten-year contract.
ITEM V. C.
Memorandum
T
o: Mayor and Council
F
rom: Tracy Hegler, City Manager
Blake Bridwell, Director of Utilities
D
ate: October 15, 2020
S
ubject: Water Treatment Plant’s SCADA Upgrades
I
ssue
T
he City’s Water Treatment Plant (WTP) Controls are fully automated and because of its complexity,
cannot be manually operated. This makes the automated systems in place critical to the WTP being able
to continuously and reliably transport, produce, and supply water to our finished water tanks for our
customers. The WTP control systems need an upgrade to keep the plant operating as normal. The
current control systems are 20 years old.
D
iscussion
T
he original Water Plant Supervisor Control and Data Acquisition (SCADA) system was installed in the
2000/2001 water plant upgrade. Nearly all components are original and still in service since that start
up. Over the course of these twenty years, we have replaced both the primary and backup computers, a
couple of power supplies, a few input/output components and had to "flash" the main Program Logic
Controller (PLC) at least twice. Our main PLC has failed twice, with the result being water plant
shutdown until an outside vendor was able to make repairs. Electronic components are outdated by any
standard, with replacement parts unavailable. This upgrade will replace the critical PLC's, input/output
modules, new main/backup computers and power supplies at the water plant, and provide more
reliability and dependable systems for continued plant operation.
C
ity Council has previously discussed this upgrade during budget discussions.
Ame
rican Engineering and MR Systems will be coordinating the work. American Engineering designed
the original WTP with these systems and has extensive knowledge for the inner-workings of the WTP.
Their experienced input on the new upgrades required is crucial to the success of the needed upgrades.
The SCADA system is a complex system with specialty software which MR Systems has maintained for
years. Their experience is also needed for successful and efficient upgrades.
Th
e attached proposals from MR Systems total to $687,124.00. The proposed work includes quotes for
PLC Replacements at the WTP and Raw Water Reservoir, Telemetry Upgrades in the water distribution
systems (new PLC’s at water tanks), and Software Upgrades. The attached agreement from American
Engineering is for a lump sum fixed fee of $59,000.00 with a section addressing any additional engineering
ITEM V. D.
services. In addition, American Engineering has recommended a contingency totaling $65,000.00. Total
for project would be $811,124.00.
The project needs to occur during the non-peak summer months to avoid peak water demand times of
the summer. A rough schedule has been included and work will be installed during winter months of
2021.
Recommendation
City staff recommends that City Council approve the City Manager to enter into an agreement with
American Engineering and MR Systems to begin the upgrades to the SCADA system at the WTP and
waive the informal and formal bid process, as both vendors have previously been awarded similar work
and have invaluable knowledge of the system.
www.mrsystems.com
1185 Beaver Ruin Rd • Norcross, GA 30093 • 678-325-2800
Page 1 of 6
MR Quote #:Q18-5126 R3
Bill of Materials and Labor
Qty Description
Cayce Water Distribution System - Hardware Upgrade
The first phase of this upgrade entails moving all of the PLC radio polling functionality to the recently-
installed Allen Bradley Micrologix 1400 in the Main Console. Currently, the polling is executed by an
obsolete Modicon Quantum PLC in the same location. By moving the functionality to the new PLC, we
can proceed with the remainder of the upgrade, which includes switching out the remote RTU hardware,
site-by-site.
Step 1: In-House development of new Polling PLC code and HMI re-addressing to incorporate new PLC registers
for Intellution application.
Step 2: On-site commissioning of new PLC programming and HMI configurations. This requires a full I/O
checkout of each site:
1) ETMF Elevated Tank
2) White Knoll Elevated Tank
3) CAE Tank and BPS
4) Hwy 321 Tank
5) Hwy 321 BPS
6) RWPS * Note site is already converted, will do partial check for functionality only
The look and feel of the HMI application will remain the same, so we do not anticipate needing to
provide any additional training for this portion of the upgrade.
Once this Phase is complete, we will be ready to begin upgrading the RTUs.
Step 3: Replace existing RTU equipment
RTU-WK White Knoll Tank PLC
Replace with new PLC based control panel
1 PLC-based Remote Telemetry Unit
Enclosure Size: 30" H x 24" W x 12" D
Enclosure Rating & Materials: NEMA 4X, #304 Stainless Steel
Solar Heat Protection: Powder-coated White Finish
PLC: Allen-Bradley MicroLogix 1400, 24 VDC with Memory Module
Available I/O: 20 DI, 14 DO, 4 AI, 2 AO
Wired I/O: 12 DI, 6 DO, 4 AI, 0 AO
AC Power Backup: Battery Backup with two (2) 9 AH Batteries
Communications: 4RF SR+ Licensed Radio
Operator Interface Terminal: Not Included
Miscellaneous Options:
Heater & Thermostat
Bulkhead-mounted RF Surge Protector
3-point Door Latch, Padlockable
Project: WDS Telemetry Upgrade
Customer: Cayce, SC
Tag/Loop
October 2, 2020
ITEM V. D.
www.mrsystems.com
1185 Beaver Ruin Rd • Norcross, GA 30093 • 678-325-2800
Page 2 of 6
MR Quote #:Q18-5126 R3
Bill of Materials and Labor
Qty Description
Project: WDS Telemetry Upgrade
Customer: Cayce, SC
Tag/Loop
October 2, 2020
Standard Features:
AC Power Surge Protector
LED Light Fixture (mounts in top of panel)
GFI Utility Outlet
RTU Door Limit Switch
Digital I/O Surge Protection: Indicating Interposing Relays
Analog I/O Surge Protection: MR Kamikaze II Analog Surge Protector
RTU-ETMF ETMF Tank PLC
Replace with new PLC based control panel
1 PLC-based Remote Telemetry Unit
Enclosure Size: 30" H x 24" W x 12" D
Enclosure Rating & Materials: NEMA 4X, #304 Stainless Steel
Solar Heat Protection: Powder-coated White Finish
PLC: Allen-Bradley MicroLogix 1400, 24 VDC with Memory Module
Available I/O: 20 DI, 14 DO, 4 AI, 2 AO
Wired I/O: 12 DI, 6 DO, 4 AI, 0 AO
AC Power Backup: Battery Backup with two (2) 9 AH Batteries
Communications: 4RF SR+ Licensed Radio
Operator Interface Terminal: Not Included
Miscellaneous Options:
Heater & Thermostat
Bulkhead-mounted RF Surge Protector
3-point Door Latch, Padlockable
Standard Features:
AC Power Surge Protector
LED Light Fixture (mounts in top of panel)
GFI Utility Outlet
RTU Door Limit Switch
Digital I/O Surge Protection: Indicating Interposing Relays
Analog I/O Surge Protection: MR Kamikaze II Analog Surge Protector
RTU-CAE CAE Tank and BPS PLC
Replace existing panel components with new Factory-Assembled backplane.
1 PLC-based Remote Telemetry Unit
Enclosure: Existing enclosure is to be reused.
Replace existing subpanel: 27" X 21"
PLC Manufacturer & Model: Allen Bradley Micrologix 1400
Communications: 4RF SR+ Licensed Radio
Available I/O: 32 DI, 8 DO, 8 AI, 4 AO
Wired I/O: 32 DI, 8 DO, 8 AI, 4 AO
AC Power Protection: Included
UPS System: Online UPS Included
Digital I/O Surge Protection: Interposing Relays included
Analog I/O Surge Protection: MR Systems' Kamikaze II
Utility Light(s): LED Fixture Included
AC Utility Power Outlet: GFI Outlet included
Panel Door Intrusion Switch: Included
www.mrsystems.com
1185 Beaver Ruin Rd • Norcross, GA 30093 • 678-325-2800
Page 3 of 6
MR Quote #:Q18-5126 R3
Bill of Materials and Labor
Qty Description
Project: WDS Telemetry Upgrade
Customer: Cayce, SC
Tag/Loop
October 2, 2020
Operator Interface: 5.7" Color Touch Display - Magellis
RTU-321TNK 321 TANK PLC
Replace existing panel components with new Factory-Assembled backplane.
1 PLC-based Remote Telemetry Unit
Enclosure Size: 30" H x 24" W x 12" D
Enclosure Rating & Materials: NEMA 4X, #304 Stainless Steel
Solar Heat Protection: Powder-coated White Finish
PLC: Allen-Bradley MicroLogix 1400, 24 VDC with Memory Module
Available I/O: 20 DI, 14 DO, 4 AI, 0 AO
Wired I/O: 20 DI, 14 DO, 4 AI, 0 AO
AC Power Backup: Battery Backup with two (2) 9 AH Batteries
Communications: 4RF SR+ Licensed Radio
Operator Interface Terminal: Not Included
Miscellaneous Options:
Heater & Thermostat
Bulkhead-mounted RF Surge Protector
3-point Door Latch, Padlockable
Replace HydroRanger 200 with LUT420 (OPTIONAL - DISCUSS WITH OWNER)
RTU-321BPS 321 BPS PLC
Replace existing PLC with new Factory-Assembled backplane.
1 PLC-based Remote Telemetry Unit
Enclosure: NONE - use existing
Replace existing subpanel: 27" X 21"
PLC Manufacturer & Model: Allen Bradley Micrologix 1400
Communications: 4RF SR+ Licensed Radio
Available I/O: 32 DI, 8 DO, 8 AI, 4 AO
Wired I/O: 32 DI, 8 DO, 8 AI, 4 AO
AC Power Protection: Included
UPS System: Online UPS Included
Digital I/O Surge Protection: Interposing Relays included
Analog I/O Surge Protection: MR Systems' Kamikaze II
Utility Light(s): LED Fixture Included
AC Utility Power Outlet: GFI Outlet included
Panel Door Intrusion Switch: Included
Operator Interface: 5.7" Color Touch Display - Magellis
RTU-RWPS Raw Water Pump Station PLC
Note: RWPS pricing is included in the WTP PLC Replacement Proposal.
MASTER Modifications to Main Radio Panel at WTP
1 4RF SR+ Licensed Radio
1 DIN Rail Adapter Kit
1 Accessory Kit
www.mrsystems.com
1185 Beaver Ruin Rd • Norcross, GA 30093 • 678-325-2800
Page 4 of 6
MR Quote #:Q18-5126 R3
Bill of Materials and Labor
Qty Description
Project: WDS Telemetry Upgrade
Customer: Cayce, SC
Tag/Loop
October 2, 2020
1 Miscellaneous Materials
SPARE RADIO Spare Licensed Radio
1 4RF Licensed Radio
TESTING Factory Acceptance Testing:
Unwitnessed Factory Acceptance Testing at MR Systems' Norcross manufacturing facility.
1 Witnessed Factory Acceptance Testing at MR Systems Columbia Office.
Project Labor
One Lot Project Engineering, Electrical Design, Mechanical Design, Drafting & Administrative Labor
(including Travel & Living expenses) as required to perform final system design and to prepare
Submittals and Record Drawings as required
One Lot HMI Software Applications Development & Graphics Design Labor (including Travel & Living
expenses) as required
One Lot PLC Control Strategy Design & Programming Labor (including Travel & Living expenses) to be
performed as required
One Lot Field Service (including Travel & Living expenses) to provide installation supervision calibrations,
startup, training, etc. as required
One Lot Electrical Installation or Terminations (including Travel & Living expenses) to provide installation of
conduit, wire, etc. as required
1 Year Onsite Comprehensive Warranty (including Travel & Living expenses)
One Lot Freight
Subtotal of Labor and Materials: $133,736
P&P Bonds: $1,534
State Sales Tax is INCLUDED. Assumed sales tax rate is: 7%, Included
Sales Tax: $5,157
Total Project Cost: $140,426
www.mrsystems.com
1185 Beaver Ruin Rd • Norcross, GA 30093 • 678-325-2800
Page 5 of 6
MR Quote #:Q18-5126 R3
Bill of Materials and Labor
Qty Description
Project: WDS Telemetry Upgrade
Customer: Cayce, SC
Tag/Loop
October 2, 2020
General Notes:
A
B
C
D
E
F
G
H
I
J
K
* Professional Engineering Authorization *
As required by the South Carolina Board of Labor, Licensing and Regulation, System Integrators are
required to hold a Certificate of Authorization to practice professional engineering in order to perform
system integration. MR Systems' Certificate of Authorization Number is C01888.
* Fiber Optic Cable Termination *
* Equipment Installation *
This quotation DOES NOT INCLUDE termination or testing of fiber optics cable.
MR Systems' South Carolina Electrical Contractor's License Number is M108855, EL5 (Unlimited).
This quotation INCLUDES the physical installation of the telemetry hardware identified above.
* Contractor License Information *
* Wiring Terminations *
* Coaxial Cable Installation *
This quotation DOES NOT INCLUDE the supply or physical installation of Communication Towers or Poles.
This quotation DOES NOT INCLUDE the supply or physical installation of conduit or wire unless specifically noted
above.
Mr. Chris Taylerson, of Heyward, Inc. in Charlotte, NC, is our local Sales Representative and will contact you prior
to the bid with pricing. Chris may be reached at 704-583-2305 (Office) or 704-591-0980 (Cell).
* Sales Representation *
* Installation of Conduit and Wire *
* Technical Questions *
For technical or scope of supply questions contact Jason Poston, P.E., of MR Systems, Inc. Jason may be
reached at 678-325-2835 (Office) or 704-918-7007 (Cell).
This quotation DOES NOT INCLUDE field or panel terminations of signal or power wires
* Fiber Optics Cable *
This quotation DOES NOT INCLUDE the supply or physical installation of Fiber Optic Cable.
This quotation DOES NOT INCLUDE the physical installation of coaxial cable or other related components.
* Installation of Communications Towers or Poles *
www.mrsystems.com
1185 Beaver Ruin Rd • Norcross, GA 30093 • 678-325-2800
Page 6 of 6
MR Quote #:Q18-5126 R3
Bill of Materials and Labor
Qty Description
Project: WDS Telemetry Upgrade
Customer: Cayce, SC
Tag/Loop
October 2, 2020
L
https://www.mrsystems.com/sellersterms/
Revision Notes:
Rev. 0 First Issue - 2019-06-03 - JAP
Rev. 1 Updated for comprehensive upgrade - 2020-01-31
Rev. 2 As offered - 2020-02-24 - J. Poston
Rev. 3 Added Bond costs - 2020-09-22 - JAP
* Terms and Conditions *
MR Systems, Inc. General Terms & Conditions of Sale apply to any order resulting from this quotation. Please refer
to the link provided below for a copy of our General Terms and Conditions of Sale.
www.mrsystems.com
1185 Beaver Ruin Rd • Norcross, GA 30093 • 678-325-2800
Page 1 of 4
MR Quote #:Q19-5127, EST Rev. 3
Bill of Materials and Labor
Qty Description
SCOPE OF WORK:
MR Systems, Inc is pleased to offer this proposal to the City of Cayce to upgrade the existing SCADA
computers and software at the Water Treatment Plant. A Modbus Plus to Ethernet converter will be
provided to allow for the new computers to communicate with the existing PLCs.
MR Systems has included in-house HMI labor to convert the application and on-site startup and testing
of the new hardware and software.
1 SCADA SOFTWARE:
Ignition Custom Redundant Package - Primary
Custom package includes the Vision, Perspective, SQL Bridge, Tag Historian, Reporting and Symbol
Factory Modules with AB and Modbus Drivers
1 Ignition Custom Redundant Package - Backup
Custom package includes the Vision, Perspective, SQL Bridge, Tag Historian, Reporting and Symbol
Factory Modules with AB and Modbus Drivers.
1 Basic Care Contract - 1 Year Term
Does not include phone support. Best for customers who want access to technical support reps via
email. Includes email support and free upgrades to any modules purchased.
SCADA HARDWARE:
1 Precision Workstation T3630 Tower - Primary Workstation
Intel Xeon E-2124, 4 Core, 8MB Cache, 3.4GHz, 4.5Ghz Turbo
NVIDIA® Quadro® P400, 2GB, 3 mDP
16GB 2x8GB DDR4 2666MHz UDIMM Non-ECC
Raid 1, (Qty. 2) 1TB, 3.5" SATA (7,200 RPM) Hard Drive
8x DVD +/- RW drive
Keyboard, Mouse
Windows 10 Pro for Workstation (Up to 4 Cores)
Microsoft Office Professional 2016
3 Year Hardware Service with Onsite/In-Home Service After Remote Diagnosis
2 Dell 24 Monitor - P2417H including Sound Bar
1 APC SmartUPS 750 VA - SMT750
1 Precision Workstation T3630 Tower - Secondary Workstation
Intel Xeon E-2124, 4 Core, 8MB Cache, 3.4GHz, 4.5Ghz Turbo
NVIDIA® Quadro® P400, 2GB, 3 mDP
16GB 2x8GB DDR4 2666MHz UDIMM Non-ECC
Raid 1, (Qty. 2) 1TB, 3.5" SATA (7,200 RPM) Hard Drive
8x DVD +/- RW drive
Keyboard, Mouse
Windows 10 Pro for Workstation (Up to 4 Cores)
Microsoft Office Professional 2016
3 Year Hardware Service with Onsite/In-Home Service After Remote Diagnosis
1 Dell 24 Monitor - P2417H including Sound Bar
1 APC SmartUPS 750 VA - SMT750
Project: WTP SCADA Software Upgrade
Customer: City of Cayce, SC
Tag/Loop
October 2, 2020
www.mrsystems.com
1185 Beaver Ruin Rd • Norcross, GA 30093 • 678-325-2800
Page 2 of 4
MR Quote #:Q19-5127, EST Rev. 3
Bill of Materials and Labor
Qty Description
Project: WTP SCADA Software Upgrade
Customer: City of Cayce, SC
Tag/Loop
October 2, 2020
Wireless Access and Plant Firewall Appliance
1 Wireless Access Point - Filter Area
1 Wireless Access Point - HS Pump Station
1 Wireless Access Point - Clarion Area
2 Apple IPAD 10.2in 32GB WiFi only
2 Applecare Warranty - 2 year
2 Otterbox Defender Case
1 Fortigate 30E Firewall Device - 3 year subscription
1 Fortiextender 201e Cellular Gateway for plant internet and RWPS Cellular access
Network Attached Storage Backup System
1 Synology DS418j NAS Appliance - 4 bay, desktop
4 WD Red Pro 4TB NAS Hard Drive
Upgraded SCADA 3D Graphics Backgrounds
MR Systems will create a complete new set of 3D Graphics backgrounds in our latest format, which is a
blend of 3D Photorealistic and Process Style interactive displays. We will overhaul the existing
menuing, alarming, and trending system with a completely new and improved interface.
MR Systems will conduct (2) Graphics workshops to collaborate with the owner and engineer on the new
interface.
Develop Monthly Reports
Flow Reports
Runtime and Cycle Reports
Chemical Usage Reports
Project Labor
One Lot Project Engineering & Administrative Labor as required to perform final system design as required.
One Lot HMI Software Applications Development Labor (including Travel & Living expenses) as required.
N/A PLC Control Strategy Design & Programming Labor (including Travel & Living expenses) as required.
One Lot Field Service (including Travel & Living expenses) to provide installation supervision calibrations,
startup, training, etc. as required.
N/A Electrical Installation or Terminations (including Travel & Living expenses) to provide installation of
conduit, wire, etc. as required.
1 Year Onsite Comprehensive Warranty (including Travel & Living expenses)
One Lot Freight
www.mrsystems.com
1185 Beaver Ruin Rd • Norcross, GA 30093 • 678-325-2800
Page 3 of 4
MR Quote #:Q19-5127, EST Rev. 3
Bill of Materials and Labor
Qty Description
Project: WTP SCADA Software Upgrade
Customer: City of Cayce, SC
Tag/Loop
October 2, 2020
Subtotal of Labor and Materials: $103,870
P&P Bonds: $1,333
State Sales Tax is INCLUDED. Assumed sales tax rate is: 7%, Included Sales Tax: $3,744
Total Project Cost: $108,947
General Notes:
A
B
C
D
E
F
* Equipment Installation *
This quotation INCLUDES installation of the above listed hardware and software.
* Wiring Terminations *
This quotation DOES NOT INCLUDE the supply or physical installation of conduit or wire unless specifically noted
above.
Mr. Chris Taylerson, of Heyward, Inc. in Charlotte, NC, is our local Sales Representative and will contact you prior
to the bid with pricing. Chris may be reached at 704-583-2305 (Office) or 704-591-0980 (Cell).
* Sales Representation *
* Installation of Conduit and Wire *
* Technical Questions *
For technical or scope of supply questions contact Jason Poston, P.E., of MR Systems, Inc. Jason may be
reached at 678-325-2835 (Office) or 704-918-7007 (Cell).
This quotation DOES NOT INCLUDE field or panel terminations of signal or power wires
* Fiber Optics Cable *
This quotation DOES NOT INCLUDE the supply or physical installation of Fiber Optic Cable.
www.mrsystems.com
1185 Beaver Ruin Rd • Norcross, GA 30093 • 678-325-2800
Page 4 of 4
MR Quote #:Q19-5127, EST Rev. 3
Bill of Materials and Labor
Qty Description
Project: WTP SCADA Software Upgrade
Customer: City of Cayce, SC
Tag/Loop
October 2, 2020
G
H
I
J
K
L
https://www.mrsystems.com/sellersterms/
Revision Notes:
Est. Rev. 0 Estimate of Probable Construction Costs - 2019-08-15 - SK
Rev. 1 Added 3D graphics option. Removed Mobus+ Gateway and configuration
Rev. 2 As Offered - 2020-02-24 - JAP
Rev. 3 Added P&P Bonds - 2020-09-22 - JAP
* Professional Engineering Authorization *
As required by the South Carolina Board of Labor, Licensing and Regulation, System Integrators are required to
hold a Certificate of Authorization to practice professional engineering in order to perform system integration. MR
Systems' Certificate of Authorization Number is C01888.
* Terms and Conditions *
MR Systems, Inc. General Terms & Conditions of Sale apply to any order resulting from this quotation. Please refer
to the link provided below for a copy of our General Terms and Conditions of Sale.
* Fiber Optic Cable Termination *
This quotation DOES NOT INCLUDE termination or testing of fiber optics cable.
MR Systems' South Carolina Electrical Contractor's License Number is M108855, EL5 (Unlimited).
* Contractor License Information *
* Coaxial Cable Installation *
This quotation DOES NOT INCLUDE the supply or physical installation of Communication Towers or Poles.
This quotation DOES NOT INCLUDE the physical installation of coaxial cable or other related components.
* Installation of Communications Towers or Poles *
www.mrsystems.com
1185 Beaver Ruin Rd • Norcross, GA 30093 • 678-325-2800
Page 1 of 6
MR Quote #:Q18-5128, R3
Bill of Materials and Labor
Qty Description
Main Control Panel Modifications
General Approach:
MR Systems proposes to provide new PLC components to replace the existing, obsolete PLC
components in the existing Main Operator Control Console. This approach will provide the City of Cayce
with all new electronic and electro-mechanical components which will last for many years to come. The
City of Cayce will also receive new electrical elementary drawings which will accurately reflect the
internal panel wiring of all I/O signals.
For the High Service and ClariCone panels, MR Systems will provide new, factory-wired complete
subpanels with all new components.
Site Visit No. 1
A MR Systems' Electrical Designer, a Field Service Engineer, and a PLC Programmer will make a site
visit to perform a detailed inspection of the existing PLC panels. The purpose of this trip is to compare
the existing panel wiring drawings to the actual wiring configuration of the existing PLC panel in order to
identify the various wiring additions and deletions that have occurred over the many years the panel
has been in service. It is likely that some existing equipment may not be presently in service or may
not be functioning. The findings resulting from this site visit will be used to prepare new Electrical
Elementaries which will be submitted to the City of Cayce for review and approval.
Site Visit No. 2
After the new Electrical Elementaries have been reviewed and approved by the City of Cayce, MR
Systems will make a second site visit to label all existing field wiring with the new panel wire numbers
per the new Electrical Elementaries. Please note that this quote does not include new labeling for the
associated field instruments, MCCs, etc. We can add this work to our scope if it is desired by the City
of Cayce.
Site Visit No. 3
After the existing field wires have been labeled with the new wire numbers, MR Systems will return to
the site to perform the following tasks:
1. Remove the existing field wires from the existing subpanels.
2. Remove any items which will be reused from the existing subpanels (i.e. the Ethernet switches, etc.
3. Reinstall the existing components that are to be reused onto the new subpanels.
4. Mount the new subpanels in the existing Operators Control Console.
5. Terminate all field wiring.
6. Perform a thorough test of all I/O from the field device through the SCADA system.
7. Relocate the existing Allen-Bradley MicroLogix 1400 (Cellular Polling PLC).
The Main Console will be upgraded in stages in efforts to reduce the amount of downtime for each
affected portion of the plant.
Stage 1
1 Assemble components for Filters 1-3 on temporary subpanel adjacent to existing panel and extend all
related wiring.
Customer: Cayce, SC
Tag/Loop
October 2, 2020
Project: WTP PLC Replacements
www.mrsystems.com
1185 Beaver Ruin Rd • Norcross, GA 30093 • 678-325-2800
Page 2 of 6
MR Quote #:Q18-5128, R3
Bill of Materials and Labor
Qty Description
Customer: Cayce, SC
Tag/Loop
October 2, 2020
Project: WTP PLC Replacements
Stage 2
Assemble components for Chemical equipment all auxiliary signals on temporary subpanel adjacent to
existing panel and extend all related wiring.
Stage 3
Shut down the existing main PLC console and install the components for Filters 4-6 and the Chemical
signals. Once this I/O is up and running, move the remaining Filter 1-3 signals over to the main
console.
1 Main Operator Control Console (Filter 1-3, Filter 4-6, Chemical)
The existing Quantum PLC will be split into three smaller subsystems, each with a processor.
This will provide for system redundancy and remove a single-point-of-failure from the system.
Mechanical:
Existing Custom Operators Control Console by Carotek, Painted Carbon Steel
Existing subpanels will remain in place
PLC Manufacturer & Model: Allen-Bradley CompactLogix (#5069-L320ER CPU for up to 16 modules)
Available I/O: 64 DI, 48 DO, 24 AI, 8 AO
Wired I/O: 64 DI, 48 DO, 24 AI, 8 AO
Programmable Logic Controller: Filter 4-6
PLC Manufacturer & Model: Allen-Bradley CompactLogix (#5069-L320ER CPU for up to 16 modules)
I/O: 64 DI, 48 DO, 24 AI, 8 AO
Wired I/O: 64 DI, 48 DO, 24 AI, 8 AO
Programmable Logic Controller: Chemical
I/O: 32 DI,32 DO, 16 AI, 32 AO
Wired I/O: 32 DI, 32 DO, 16 AI, 32 AO
Communications:
Allen-Bradley's Ethernet/IP - Hirschmann RS20 Ethernet switch will be provided.
The existing Allen-Bradley MicroLogix 1400 PLC will be reinstalled and will continue to poll the Cellular
Remote Sites.
AC Power Distribution:
(2) new online UPS will be provided with independent UPS Power Failover Circuit
DC Power Distribution:
Existing DC Power Supplies will be replaced with new Delta Power Supplies.
Note: City to supply 2nd AC power circuit for this panel for redundancy purposes.
www.mrsystems.com
1185 Beaver Ruin Rd • Norcross, GA 30093 • 678-325-2800
Page 3 of 6
MR Quote #:Q18-5128, R3
Bill of Materials and Labor
Qty Description
Customer: Cayce, SC
Tag/Loop
October 2, 2020
Project: WTP PLC Replacements
1 ClariCone Control Panel
Mechanical:
Existing 36" H x 36" W x 1 " D NEMA 4 Control Panel by Nix, Purser & Associates
Rear Subpanel: 33" H x 33" W
Programmable Logic Controller:
PLC Manufacturer & Model: Allen-Bradley CompactLogix (#5069-L320ER CPU for up to 16 modules)
Available I/O: 32 DI, 32 DO, 16 AI, 8 AO
Wired I/O: 32 DI, 32 DO, 16 AI, 8 AO
Communications:
Communications protocol will be Allen-Bradley's Ethernet/IP. A new Hirschmann RS20 Ethernet switch
will be provided.
AC Power Distribution:
Existing AC Power distribution to remain with minor modifications.
A new online UPS will be provided.
A new UPS Power Failover Circuit will be installed.
DC Power Distribution:
Existing DC Power Supplies will be replaced with new Delta Power Supplies.
1 High Service Pump Station Control Panel
Mechanical:
Existing 36" H x 36" W x 1 " D NEMA 4 Control Panel by Nix, Purser & Associates
Rear Subpanel: 33" H x 33" W
Programmable Logic Controller:
PLC Manufacturer & Model: Allen-Bradley CompactLogix (#5069-L320ER CPU for up to 16 modules)
Available I/O: 32 DI, 32 DO, 16 AI, 16 AO
Wired I/O: 32 DI, 32 DO, 16 AI, 16 AO
Communications:
Communications protocol will be Allen-Bradley's Ethernet/IP. A new Hirschmann RS20 Ethernet switch
will be provided.
AC Power Distribution:
Existing AC Power distribution to remain with minor modifications.
A new online UPS will be provided.
A new UPS Power Failover Circuit will be installed.
DC Power Distribution:
Existing DC Power Supplies will be replaced with new Delta Power Supplies.
1 Raw Water Pump Station Control Panel
Mechanical:
Existing 36" H x 36" W x 1 " D NEMA 4 Control Panel by Nix, Purser & Associates
www.mrsystems.com
1185 Beaver Ruin Rd • Norcross, GA 30093 • 678-325-2800
Page 4 of 6
MR Quote #:Q18-5128, R3
Bill of Materials and Labor
Qty Description
Customer: Cayce, SC
Tag/Loop
October 2, 2020
Project: WTP PLC Replacements
Rear Subpanel: 33" H x 33" W
Programmable Logic Controller:
PLC Manufacturer & Model: Allen-Bradley CompactLogix (#5069-L320ER CPU for up to 16 modules)
I/O: 32 DI, 32 DO, 16 AI, 16 AO
Communications:
Communications protocol will be Allen-Bradley's Ethernet/IP. A new Hirschmann RS20 Ethernet switch
will be provided.
AC Power Distribution:
Existing AC Power distribution to remain with minor modifications.
A new online UPS will be provided.
A new UPS Power Failover Circuit will be installed.
DC Power Distribution:
Existing DC Power Supplies will be replaced with new Delta Power Supplies.
SCADA Controls Design Workshops
To be held at American Engineering or MR Systems Columbia Office
1). Preliminary Design Workshop
2). Intermediate Design Workshop
3). Final Design workshop before factory testing
Factory Acceptance Testing:
Unwitnessed Factory Acceptance Test at MR Systems Columbia Office
1 Witnessed Factory Acceptance Test at MR Systems Columbia Office
Note: If Modicon M340 PLC Hardware, without the use of quick-conversion kits, the total price can be
reduced by approximately $28,000.00.
Project Labor
One Lot Project Engineering, Electrical Design, Mechanical Design, Drafting & Administrative Labor
(including Travel & Living expenses) as required to perform final system design and to prepare
Submittals and Record Drawings as required by the Contract Documents.
One Lot HMI Software Applications Development & Graphics Design Labor (including Travel & Living
expenses) as required by the Contract Documents.
One Lot PLC Control Strategy Design & Programming Labor (including Travel & Living expenses) to be
performed as required by the Contract Documents.
www.mrsystems.com
1185 Beaver Ruin Rd • Norcross, GA 30093 • 678-325-2800
Page 5 of 6
MR Quote #:Q18-5128, R3
Bill of Materials and Labor
Qty Description
Customer: Cayce, SC
Tag/Loop
October 2, 2020
Project: WTP PLC Replacements
One Lot Field Service (including Travel & Living expenses) to provide installation supervision calibrations,
startup, training, etc. as required by the Contract Documents.
One Lot Electrical Installation or Terminations (including Travel & Living expenses) to provide installation of
conduit, wire, etc. as required by the Contract Documents.
1 Year Onsite Comprehensive Warranty (including Travel & Living expenses)
One Lot Freight
Subtotal of Labor and Materials: $421,000
P&P Bonds: $3,430
South Carolina State Sales Tax is INCLUDED. Assumed sales tax rate is:
7%, Included Sales Tax: $13,321
Total Project Cost: $437,751
General Notes:
* Performance and Payment Bonds *
AAbove pricing does not include Performance and Payment Bonds or other specialty insurance.
B
C
D
E
F
G
This quotation INCLUDES the re-terminations of panel and/or field wiring where required.
* Fiber Optics Cable *
This quotation DOES NOT INCLUDE the supply or physical installation of conduit or wire unless specifically noted
above.
Mr. Chris Taylerson, P.E., of Heyward, Inc. in Charlotte, NC, is our local Sales Representative. Chris may be
reached at 704-583-2305 (Office) or 704-591-0980 (Cell).
* Sales Representation *
* Installation of Conduit and Wire *
* Technical Questions *
For technical or scope of supply questions contact Jason Poston, P.E., of MR Systems, Inc. Jason may be
reached at 678-325-2835 (Office) or 704-918-7007 (Cell).
* Equipment Installation *
This quotation INCLUDES the physical installation of the new PLC hardware in the existing enclosures.
* Wiring Terminations *
www.mrsystems.com
1185 Beaver Ruin Rd • Norcross, GA 30093 • 678-325-2800
Page 6 of 6
MR Quote #:Q18-5128, R3
Bill of Materials and Labor
Qty Description
Customer: Cayce, SC
Tag/Loop
October 2, 2020
Project: WTP PLC Replacements
H
I
J
K
L
M
https://www.mrsystems.com/sellersterms/
Revision Notes:
Rev. 0 First Issue - Estimate of Probable Construction Cost - 2019-02-20 - THH
Rev. 1 Updated for distributed PLC controls - 2020-01-31 - JAP
Rev. 2 As Offered with Allen-Bradley CompactLogix PLC Hardware - 2020-02-24 - JAP
Rev. 3 Added bond costs - 2020-09-22 - JAP
This quotation DOES NOT INCLUDE the supply or physical installation of Fiber Optic Cable.
This quotation DOES NOT INCLUDE the physical installation of coaxial cable or other related components.
* Installation of Communications Towers or Poles *
* Professional Engineering Authorization *
As required by the South Carolina Board of Labor, Licensing and Regulation, System Integrators are
required to hold a Certificate of Authorization to practice professional engineering in order to perform
system integration. MR Systems' Certificate of Authorization Number is C01888.
* Terms and Conditions *
MR Systems, Inc. General Terms & Conditions of Sale apply to any order resulting from this quotation. Please
refer to the link provided below for a copy of our General Terms and Conditions of Sale.
* Fiber Optic Cable Termination *
This quotation DOES NOT INCLUDE termination or testing of fiber optics cable.
MR Systems' South Carolina Electrical Contractor's License Number is M108855, EL5 (Unlimited).
* Contractor License Information *
* Coaxial Cable Installation *
This quotation DOES NOT INCLUDE the supply or physical installation of Communication Towers or Poles.
1
AGREEMENT FOR PROFESSIONAL ENGINEERING SERVICES
This Agreement is hereby made this _____ day of ____________ 20___ between American
Engineering Consultants, Inc. (hereinafter referred to as the ENGINEER) and the City of Cayce,
SC (hereinafter referred to as the OWNER). The ENGINEER hereby agrees to serve as the
OWNER'S professional engineering representative in connection with the STANLEY L.
GOODWIN WATER TREATMENT PLANT ( WTP) SCADA SY STEM UPGRADE (hereinafter
known as the PROJECT as outlined in the Project Description below). The ENGINEER proposes
to assist and advise the OWNER and nothing contained herein shall confer any rights or create
any duties on the part of the ENGINEER towar d any person or persons not a party to this
Agreement.
PROJECT DESCRIPTION:
Improvements to the existing SCADA System at the Stanley L. Goodwin WTP and associated
remote sites consisting of the following: 1) installation of new Programmable Logic Controllers
(PLCs) and related components to replace existing obsolete PLCs in the Main Operator Control
Console, Claricone PLC Panel and High Service Pump Station PLC Panel at the WTP; 2)
Upgrade of existing SCADA system computers and software at the WTP; 3) Modifications to Main
Radio Panel at WTP and c onfiguration of radio polling functionality on new WTP Main Operator
Control Console PLC and r eplacement of existing RTUs/PLCs and telemetry equipment at the
following remote locations: White Knoll Elevated Storage Tank, ETMF Storage Tank, CAE
Storage Tank and Booster Pump Station, Highway 321 Storage Tank, Highway 321 Booster
Pump Station and Raw Water Pump Station.
WITNESSETH:
That for and in consideration of the mutual covenants and promises between the parties hereto,
it is hereby agreed:
SECTION A - ENGINEERING SERVICES
The ENGINEER shall furnish the following services:
1. ENGINEER will attend meetings and workshops with OWNER and Systems Integrator
as necessary to assist in the development of a comprehensive project scope.
2. ENGINEER will review the project scope/proposal provided by Systems Integrator and
make any necessary recommendations for revisions to OWNER.
3. Upon receipt of final project scope/proposal from Systems Integrator, ENGINEER will
prepare Contract Documents for the Work. The Contract Documents will consist of a
Contract and associated General and Supplemental Conditions for the work outlined in
the proposal provided by the Systems Integrator. ENGINEER will provide three (3)
copies of the Contract Documents for execution by OWNER and Systems Integrator.
4. ENGINEER will review on behalf of the OWNER submittals for hardware and software
products and elementary electrical drawings and schematics furnished by the Systems
Integrator.
5. ENGINEER will conduct a meeting with OWNER and Systems Integrator prior to the
start of on-site work activities to review the schedule and sequence of work.
2
6. ENGINEER will conduct meetings and workshops with OWNER and Systems Integrator
as required during S ystem Integrator’s design and engineering phase to assist with
System Integrator’s understanding of functional requirements of the plant processes and
remote sites based on ENGINEER’S knowledge of plant processes and pr evious
involvement design and construction of the plant and remote sites.
7. ENGINEER will provide general engineering review of the work of the Systems
Integrator during the period of on-site work. The ENGINEER’S undertaking hereunder
shall not make the ENGINEER an insurer of the Systems Integrator’s performance.
8. ENGINEER shall provide assistance to OWNER and Systems Integrator during PLC
programming and onsite program implementation and troubleshooting with regard to
functional requirements of plant processes . ENGINEER will assist OWNER and
Systems Integrator with troubleshooting and fine tuning of plant processes during the
switchover from the existing to the new PLCs.
9. ENGINEER will conduct progress meetings with OWNER and Systems Integrator as
needed during installation to review progress and any other issues related to the
completion of the project.
10. ENGINEER will review the Systems Integrator’s applications for progress and final
payment and when approved, submit same to the OWNER for payment.
11. ENGINEER will prepare necessary contract change orders for approval of the OWNER
and Systems Integrator.
12. ENGINEER will make a final review prior to the issuance of the statement of substantial
completion of all work, develop a punchlist of remaining work to be completed by
Systems Integrator and submit a written report to the OWNER. Prior to submitting the
final pay estimate, the ENGINEER shall submit a statement of completion to the
OWNER.
SECTION B - COMPENSATION FOR ENGINEERING SERVICES
1. The OWNER shall compensate the ENGINEER for the services as described above for
the following LUMP SUM FIXED FEES: $59,000.
2. The OWNER will compensate the ENGINEER on a monthly basis for all services.
SECTION C - ADDITIONAL ENGINEERING SERVICES
1. Compensation to the ENGINEER for any Additional Services not outlined above will be
negotiated with the OWNER prior to commencement of the work . The ENGINEER shall
render to the OWNER for such services an itemized bill, separate from any other billing,
once each month, for compensation for services performed hereunder during such
period.
2. The OWNER shall reimburse the ENGINEER for all direct expenses and printing costs
associated with this project based on the ENGINEER’S Rate Schedule included
herewith.
3
SECTION D - INTEREST ON UNPAID SUMS
If the OWNER fails to make any payment due the ENGINEER within 30 days for services and
expenses, then the ENGINEER shall be entitled to interest at the rate of 1 1/2 % per month (18
% per annum).
SECTION E - GENERAL CONDITIONS
1. Ownership of Documents: All documents, including original drawings, estimates,
specifications, field notes, and data are and remain the property of the ENGINEER as
instruments of service.
2. Termination: This agreement may be terminated by either party for cause upon seven
(7) days written notice should the other party fail substantially to perform in accordance
with the terms of this agreement through no fault of the other. In the event of
termination, the ENGINEER will be paid compensation for services performed and
reimbursables incurred up to the time of termination.
3. Cancellation: Because of potentially significant revenues from other projects forgone by
the ENGINEER in order to take on this project, if this project is canceled by the OWNER,
a cancellation fee of 20% of the lump sum fee shall be immediately due and payable.
4. Project Restart: Because of the costs involved in stopping and restarting a project once
it is underway, should the projects progress be halted by the OWNER at any time, for
any reason, for a period exceeding 30 calendar days, a project restart fee of 10% of the
total fee earned to date not to exceed 5% of the total fee nor less than $1,000.00 will be
immediately due and payable.
5. Hazardous Waste: The ENGINEER assumes no responsibility for any hazardous
material that may be encountered on this site during the course of this project and will be
indemnified and held harmless for all liability associated with the removal, encapsulation,
or containment thereof. Any hazardous material required to be removed, encapsulated,
or otherwise contained during the course of this project will result in compensation of the
ENGINEER by the OWNER at rates as shown on the attached rate schedule for any
drawings, specifications, or construction observation services as required.
6. Legal Responsibilities: Should the ENGINEER institute legal proceedings on account of
alleged failure by the OWNER to perform in accordance with its terms, the OWNER shall
pay for all cost s, legal or otherwise, incurred by the ENGINEER in course of said action
provided judgment is rendered against the OWNER in a court of law or court of arbitration.
7. Modifications to this Agreement: The OWNER may, from time to time, request changes in
the scope of services of the ENGINEER to be performed thereunder. Such changes, any
increase or decrease in the amount of the ENGINEER'S compensation or any other
changes, modifications, additions to, or deletions from this Agreement shall only be
effective upon the mutual agreement of both the OWNER and ENGINEER in writing.
4
8. Successors and Assigns: This Agreement shall be binding upon the parties hereto, their
respective successors, heirs, executors, administrators, and assigns with the stipulation
that this Agreement and any rights or responsibilities arising therefrom cannot be
assigned without the prior written approval of the parties, and in the event of such
assignment, this Agreement may be t erminated by the non- assigning party for cause or
convenience, as appropriate.
9. Notice: Any notice by the OWNER to the ENGINEER, or any notice by the ENGINEER to
the OWNER, may be given and shall be deemed to have been duly served if either
delivered personally or mailed in any general or branch post office enclosed in a certified
or registered postpaid envelope addressed as follows:
As to the OWNER:
The City of Cayce, SC
P. O. Box 2004
Cayce, South Carolina 29171
As to the ENGINEER:
American Engineering Consultants, Inc.
PO Box 2299
Cayce, South Carolina 29171
10. Period of Service: The ENGINEER'S period of service will begin upon notice from the
OWNER to proceed and shall expire 30 days after the construction contractor has
completed the final punch list, and if required after final approval has been obtained from
SCDHEC for the PROJECT. If the OWNER requests significant modifications or changes
in the scope of the PROJECT, the time of performance shall be appropriately adjusted.
11. Applicable Law: Both the ENGINEER and OWNER agree that they will comply with all
applicable Federal, State, and Local laws, ordinances, and codes in the performance of
this Agreement. This Agreement shall be governed by and construed in accordance with
the laws of the State of South Carolina.
12. Entire Agreement:
a. If any provision in this Agreement shall be held to be invalid or unenforceable, the
remaining portions shall remain in effect. In the event such invalid or unenforceable
provision is cons idered an essential part of this Agreement, the parties shall promptly
negotiate a replacement provision.
b. The failure of either party to insist upon the strict performance of any terms, conditions,
and covenants herein set forth shall not be deemed a waiver of any rights or remedies
that such party may have and shall not be deemed a waiver of any subsequent breach or
default in the terms, conditions, and covenants herein contained.
c. This document contains the entire Agreement between the parties and no statement or
representation not contained herein shall be valid.
AMERICAN ENGINEERING CONSULTANTS, INC.
RATE SCHEDULE
2020
PRINCIPAL ENGINEER $180.00 PER HOUR
PROJECT MANAGER $150.00 PER HOUR
PROJECT ENGINEER $130.00 PER HOUR
REGISTERED LAND SURVEYOR $120.00 PER HOUR
DESIGN ENGINEER $115.00 PER HOUR
SURVEY MANAGER $90.00 PER HOUR
DESIGN TECHNICIAN $85.00 PER HOUR
SENIOR CAD TECHNICIAN $80.00 PER HOUR
CAD TECHNICIAN $70.00 PER HOUR
SENIOR FIELD TECHNICIAN $80.00 PER HOUR
FIELD TECHNICIAN $70.00 PER HOUR
ADMINISTRATOR $80.00 PER HOUR
CLERICAL $55.00 PER HOUR
SURVEY CREW – 2 MAN $160.00 PER HOUR
SURVEY CREW – 3 MAN $240.00 PER HOUR
COPIES (24" x 36") $1.50 PER EACH
COPIES (30" x 42") $2.25 PER EACH
COPIES (8 ½ x 11) $0.40 PER EACH
COPIES (8 ½ x 14 or 11 x 17) $0.60 PER EACH
COLOR PLOTS (24" x 36") $20.00 PER EACH
COLOR PLOTS (30" x 42") $30.00 PER EACH
MYLAR PLOTS (24" x 36") $40.00 PER EACH
MYLAR PLOTS (30" x 42") $50.00 PER EACH
MILEAGE $0.60 PER MILE
DIRECT EXPENSES COST PLUS 15 %
SPECIAL SERVICES: The above Hourly Rates shall be increased by a factor of 1.5 f or
courtroom appearances (including preparation) and for overtime
hours.
CONDITIONS: The above Rate Schedule shall be in effect through December 31,
2020. Rates are subject to change upon notification. Any revision
shall be included in Documents of which this schedule is a part.
No. Task Start Date Days to Complete End Date Phase
1 Mobilization 1/1/2021 14 1/15/2021 Design and Engineering
2 Site Research 1/15/2021 21 2/5/2021 Design and Engineering
3 Preliminary Design 2/5/2021 30 3/7/2021 Design and Engineering
4 Workshops 3/7/2021 7 3/14/2021 Design and Engineering
5 Design 3/14/2021 60 5/13/2021 Design and Engineering
6 Workshops 5/13/2021 7 5/20/2021 Design and Engineering
7 Final Design 5/20/2021 45 7/4/2021 Design and Engineering
8I n House Programming 7/4/2021 80 9/22/2021 In House Development
9 UFAT 9/22/2021 14 10/6/2021 In House Development
10 FAT 10/6/2021 14 10/20/2021 In House Development
11 Telemetry PLC Upgrade 10/20/2021 21 11/10/2021 On Site Installation
12 Plant PLC Upgrade 11/10/2021 42 12/22/2021 On Site Installation
13 SCADA Upgrade 12/22/2021 21 1/12/2022 On Site Installation
14 Final Cleanup 1/12/2022 14 1/26/2022 Closeout
15 Training 1/26/2022 10 2/5/2022 Closeout
TOTAL 400
City of Cayce
Committee Appointments/Reappointments
October 21, 2020
All open positions will be advertised on the City’s website and Facebook page.
COUNCIL ACTION REQUIRED
CAYCE HISTORICAL MUSEUM COMMISSION – ONE (1) POSITION
The Historical Museum Commission currently has one (1) open position. The City has received a
potential member application form Mr. David Brinkman. Mr. Brinkman attended the Museum
Commission’s October 7, 2020 meeting and the Commission voted unanimously to recommend him for
appointment.
C
AYCE MUNICIPAL ELECTION COMMISSION – ONE (1) POSITION
One of the members of the Commission currently cannot serve due to health reasons. The City has
received a potential member application from Ms. Augusta Thompson. Her application is attached for
Council’s review.
NO COUNCIL ACTION REQUIRED
The following positions have been postponed by Council until receipt of potential member
applications.
A
CCOMMODATIONS TAX COMMITTEE – ONE (1) POSITION
The open position must be filled by someone from the motel industry in Cayce.
CAYCE HOUSING AUTHORITY – ONE (1) POSITION
Mr. Edward Landry no longer lives in the City. There are no recommendations at this time.
S
TANDARD TECHNICAL CODES BOARD OF APPEALS – TWO (2) POSITIONS
Members who serve on this Board must be either an Engineer, Contractor, Architect or Design
Professional. There are no recommendations at this time.
ITEM VI. A.
ITEM VI. A.
CI
TY OF CAYCE
POTENTIAL MEMBER APPLICATION
Name: ____________Augusta Thompson
Home Address: __2119 Middleton St_ City, State, Zip _Cayce, SC 29033___
Telephone: __410-322-9214_____ E-Mail: ____Augustaathompson@gmail.com______
Resident of Cayce: X Yes No Number of Years: ___11_______
P
lease indicate the Committee(s) for which you are applying:
Accommodations Tax Committee Cayce Housing Authority Events Committee
Consolidated Board of Appeals X Municipal Election Comm Museum Commission
Planning Commission Board of Zoning Appeals
H
ave you ever been convicted of a felony or misdemeanor other than a minor traffic violation?
□ Y
es X No If yes, specify below.
___________________________________________________________________________
___________________________________________________________________________
Work Address
Company: ___Nelson Mullins ________ Position: ____Data Analyst_____
Address: ___1320 Main St _ _____ City, State, Zip __Columbia SC 29205_____
Telephone: ___803-255-9512______ E-Mail: augusta.thompson@nelsonmullins.com_____
Work Experience: ___Nelson Mullins 2015-2020; DTI Global 2013-2015____
__________________Starbucks 1999-2013______________________
Educational Background: __Towson University 1998-2004_____________
________________________Midlands Tech Continuing Education 2020____________
Membership Information (Professional, Neighborhood and/or Civic Organizations):
____________________________________________________________________________
Volunteer Work: ___Congaree Riverkeeper Volunteer_______________________
____________________________________________________________________________
Hobbies: ____Reading, Re-learning to sew________________________________________
____________________________________________________________________________
R
eturn to:
Mendy Corder, Municipal Clerk
City of Cayce, PO Box 2004, Cayce, SC 29171-2004
Telephone: 803-550-9557 Fax: 803-796-9072 Email: mcorder@caycesc.gov
ITEM VI. A.
Source: City of Cayce website. First collected Nov 13, 2026.