Backup Material
Oconee County · Oconee County · meeting of Mar 3, 2025 · Other
Open the original document More from Oconee County
Text
Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.
COMMISSION MEMBERS
Mike Johnson, At-Large David Nix, District 2
Teresa Spicer, District 1 Brit Adams, District 3
Joe Fravel, District 4 Jake Marcengill, District 5
Mickey Haney, At-Large
AGENDA
6:00 pm, Monday, March 3, 2025
Council Chambers - Oconee County 415 S Pine St, Walhalla SC 29691
1. Call to Order
2. Invocation
3. Pledge of Allegiance
4. Approval of minutes from February 3, 2025
5. Public Comment for Non-Agenda Items (4 minutes per person)
6. Commission Member Comments
7. Planning Staff Comments
8. Discussion and recommendation to council regarding subsequent rezoning of parcel 111-24-01-010
from split zoning in both LRD and CCD to all in CCD.
a. Public Comment
b. Discussion/ vote
9. Public Hearing- The renaming of Jefferson Place to Cherry Tree Place or Rose Bush Lane, consistent
with S.C. Code § 6-29-1200 and the Oconee County Road Naming and Addressing Policy.
a. Discussion/ Vote
10. Discussion regarding amending Chapter 38 article 9, Sec 38-9.3 Dimensional requirements: general
provisions and exceptions 2. Setbacks, j. “Steps and heating and cooling units may project into a
required yard a distance not to exceed five feet but no closer than five feet of a property line.
Fences, freestanding walls, hedges, and septic lines may be located in any setback, so long as they
remain on the property.”
a. Public Comment
b. Discussion/ vote
11. Adjourn
1
COMMISSION MEMBERS
Mike Johnson, Chairman, At-Large David Nix, Vice Chair, District 2
Teresa Spicer, District 1 Brit Adams, District 3
Joe Fravel, District 4 Jake Marcengill, District 5
Mickey Haney, At-Large
STAFF
James Coley
Elise Dunaway
MINUTES
6:00 pm, Monday, February 3, 2025
Council Chambers - Oconee County 415 S. Pine St, Walhalla SC 29691
1. Call to Order – Mr. Johnson called the meeting to order at 6:00 PM.
2. Invocation was led by Mr. Root.
3. Pledge of Allegiance was led by Mr. Haney.
4. Approval of minutes from January 6, 2025 – Mr. Adams made a motion to approve the
minutes; Seconded by Mr. Nix. Approved Unanimously.
5. Election of Officers
Mr. Nix nominated Mr. Johnson as Chairman of the Planning Commission. Approved
unanimously.
Mr. Haney nominated Mr. Nix as Vice Chairman of the Planning Commission. Approved
Unanimously.
Mr. Johnson nominated Mr. Coley as Secretary of the Planning Commission. Approved
Unanimously.
6. Public Comment for Non-Agenda Items (4 minutes per person):
Mr. Tom Markvoich voiced his opinion regarding retaining walls within the setbacks.
7. Commission Member Comments:
Mr. Nix welcomed Mr. Fravel and Mr. Marcengill to the Planning Commission.
Mr. Haney thanked Mr. Markovich for attending the meeting and requested the public to
attend meetings more often.
Mr. Johnson hopes to continue moving forward in the coming year and continue to make
improvements where needed in Oconee County.
2
8. Discussion regarding the Scenic Highway Ordinance and potential changes or
amendments.
a. Public Comment
b. Discussion/ vote
Mr. Nix made a motion to approve the ordinance as written with the included
amendment; Seconded by Mr. Haney. Approved Unanimously.
Mr. Johnson made an amendment to the motion that in the application Mr. Root
include that the applicant is to be contacted by the county if complaints are being
received and include a 45-day response period; Seconded by Mr. Adams. Approve
Unanimously.
9. Adjourn – the meeting was adjourned at 6:24 PM.
3
80
60
61
62
63
58
56
57
86
59
87
53
85
84
83
82
81
79
55
54
64
65 66 67
68
69
7678
77
75
74
72
71
70
73
IPO 1/2" RB
IPO 5/8" RB
OLD RR SPIKE
IPO 1/2" RB
IPO 1/2" RB BENT
IPO 1/2" RB BENT
OLD CON MON "DPCO"IPO 5/8" RB
IPO 1/2" RB
@ 44.76'
REF IPO 1/2"
RB @ 59.79'
IPO 1/2" RB
IPO 1/2" OT
IPO 3/4" CT
IPO 1" SR FF=833.98 DECKCANOPY
0.9' ENCROACHMENT
IPO 3/4" CT
IPO 3/4" CT
IPO 1/2" RB
IPO 1/2" RB
IPO 1/2" RB
IPO 1" OT
IPO 1/2" RB
IPO 1/2" RB
IPS 1/2" RB
IPO 1/2" RB UNDER ROOT
IPO 1/2" RB BENT
DOCK
TETHER
TETHER
FF=834.37FF=824.18IPO 1/2" RB
IPO 1/2" RB
IPO 1/2" RB
IPO 1/2" RB
IPO 3/4" OT
IPO 1/2" RB
IPO 3/4" OT
IPO 1" OT
IPO 3/4" OT
IPO 1" SR
IPO 3/4" OT
IPO 1" OT
IPO 1" SR
IPO 1/2" RB BENT
IPO 3/4" OT
IPO 1/2" RB
IPO 1/2" RB
IPO 1/2" RB
IPO 1/2" RB
IPO 3/4" OT BENTOLD SUB READING
IPO 1/2" RB
OLD NAIL IN CAP
IPO 1/2" RB
IPO 1/2" RB IPO 1/2" RB
IPO 1/2" RB
IPO 1/2" RB
IPO 1/2" RB
IPO 1/2" RB
IPO 1/2" RB
IPO 1/2" RB
ASPHALT
EP
EP
EP
EP
EP
EP
EP
ADJOINER'S
POND
ASPHALT
EPEP 1.3' ENCROACHMENT
RAILROAD TIE WALL
BLOCK WALL
PORCH
ASPHALT
STONE WALL
EDGE OF WATER
(TM# 177-00-02-007)
PT (TYP)
PT (TYP)
BRICK WALL
ARMANDA WAY
BROWN WOOD DRIVE
BUFFALO ROAD
HIDDEN FALLS DRIVE
LAKE KEOWEE
(SUBJECT TO R/W)
(SUBJECT TO R/W)
IPO 1/2" RB BENT
(INCLUDES ANY AND ALL R/W)
1 inch = ft.
( IN FEET )
GRAPHIC SCALE
0 125
125
125 50025063
LOCATION MAP NOT TO SCALE
SHEET OF
HORZ. SCALE:
VERT. SCALE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
DATE:
NO.
DATE
www.sitedesign-inc.com
225 ROCKY CREEK ROAD
GREENVILLE, SC 29615
PH: (864) 271-0496
SITE DESIGN, INC.
CIVIL ENGINEERS - SURVEYORS - LANDSCAPE ARCHITECTS
1.2.3.4.5.6.7.8.9.10.THIS DRAWING IS THE PROPERTY OF SITE DESIGN, INC. AND IS
FURNISHED WITH THE CONDITION THAT IT IS NOT TO BE CHANGED
WITHOUT THE WRITTEN AUTHORIZATION OF SITE DESIGN, INC.
FURTHERMORE, THIS DRAWING IS NOT TO BE COPIED, REPRODUCED,
OR USED BY OTHERS EXCEPT AS REQUIRED FOR THE WORK OF THIS
SPECIFIC PROJECT.
© 2023 SITE DESIGN, INC.
U
FI
R ITEC
E
AC
T
A
FO
Z RI
HT
O
I TA
ON
S
H
UT
O
CA
AN
R
LO
I
SITE
DESIGN
INC.
No. C00122
W E
S
N
MELTON RD
OLD WALHALLA HWY
WINSTON WAY
S-37-341
S-37-35
S-37-220
S-37-107
W UNION RD
LINHART RD S-37-573
SITE
HIDDEN FALLS DR
BUFFALO RD
LICENSED PROFESSIONAL ENGINEER
STEPHANIE PO
HLMAN GATES
A
A
IL
RO
N
C
No. 29077UOS
HT
12/16/2024
1" = 125'
N/A
24
HIDDEN FALLS
SUBDIVISION PH 2
MCJ
SPG
12/16/2024
S230651/BASE_SHEETS
MCJ
S.C. REG 29077
C200
5
SITE PLAN OVERALL
OCONEE COUNTY
SOUTH CAROLINA
DISTINGUISED DESIGN
LLC
THE UTILITIES SHOWN ARE SHOWN FOR THE CONTRACTOR'S CONVENIENCE ONLY.
THERE MAY BE OTHER UTILITIES NOT SHOWN ON THESE PLANS. THE ENGINEER
ASSUMES NO RESPONSIBILITY FOR THE LOCATIONS SHOWN AND IT SHALL BE THE
CONTRACTOR'S RESPONSIBILITY TO VERIFY THE LOCATIONS OF ALL UTILITIES
WITHIN THE LIMITS OF THE WORK. ALL DAMAGE MADE TO EXISTING UTILITIES
BY THE CONTRACTOR SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR.
***CAUTION***
Know what's below.Call before you dig.
STORMWATER FLOW
TRAFFIC FLOW
STORMWATER FLOW
TRAFFIC FLOWIE INVERT ELEVATION
W
ROOF DRAIN - NEW
WATER - NEW
CONTOURS - FINISHED GRADE
CHAIN LINK FENCE (EXISTING)
CHAIN LINK FENCE (PROPOSED)
(678)
LINETYPES
UNDERGROUND TEL
SANITARY SEWER - EXIST.
WOOD FENCE
CABLE TV
FIBER OPTIC UNDERGROUND POWER
OVERHEAD POWER
GAS LINE W
UGT
UGP
SD
SS
SS
RD
OHT
OHP
GAS
FM
FOC
X
X
CTV
FORCE MAIN
STORM SEWER - NEW
STORM SEWER - EXIST.
SANITARY SEWER - NEW
CONTOURS - EXIST. GRADE680
SILT FENCE
OVERHEAD TELEPHONE
WATER LINE - EXIST.
LEGEND
SF
NPDES LIMITS OF DISTURBANCE
CO CLEAN OUT
ELECTRIC METER
TELEPHONE MANHOLE
VCP VITRIFIED CLAY PIPE
REINFORCED CONC PIPERCP
CMP CORRUGATED METAL PIPE
STORM DRAINSD
SANITARY SEWERSS
PP POWER POLE
WM
WV
WATER METER
WATER VALVE
TELEPHONE PEDESTALTEL
CATCH BASIN
DROP INLET
ELEVATION
GM
GAS VALVE
FIRE HYDRANT
GAS METER
ELEC TRANS
CB
DI
GV
DYH
D
S
SD MANHOLE
SS MANHOLE
LIGHT POLE
SDMH
SSMH
LP
CL
BL
EP
DE
CT
N&C
IPS
IPO
R/W
RB
OT
SSE SS EASEMENT
RIGHT OF WAY
OPEN TOP
REBAR
NAIL & CAP
IRON PIN SET-
EDGE OF PAVEMENT
IRON PIN OLD-
DRAINAGE EASEMENT
CENTERLINE
CRIMP TOP
BUILDING LINE
GP GUY ANCHOR
EM TOP/BOTTOM WALLTW/BW
TOP/BOTTOM CURBTC/BC
TTMH
PIV POST INDICATOR VALVE90.0x
CABLE TV PEDESTALCATV
GREASE TRAP MANHOLEGT
FFE FINISHED FLOOR ELEVATION
FG FINISHED GRADE
The contractor shall coordinate with the engineer of record for a digital staking plan to
establish complete horizontal and vertical control. The contractor is responsible for
survey stakeout of all improvements. Discrepancies between the plans, construction
stakes, and field conditions shall be reported to the engineer of record immediately for
resolution prior to installation of proposed improvements.”
TOTAL SITE
DISTURBANCE:
24.1 ACRES
SITE DATA
SITE ADDRESS HIDDEN FALLS DRIVE
WEST UNION, SC 29696
OWNER/DEVELOPER DISTINGUISHED DESIGN LLC
535 ST MARK RD
TAYLORS, SC 29687
CONTACT: DAVID HAZEL
864-304-6087
CIVIL ENGINEER SITE DESIGN, INC.
225 ROCKY CREEK ROAD
GREENVILLE, SC 29615
ZONING LRD
LAKE RESIDENTIAL
PROPOSED USE SINGLE FAMILY DETACHED
TAX MAP # TMS# 1770002007, 1770002212,
1770002214
PARCEL AREA 36.4 ACRES
SETBACKS FRONT: 25'
SIDES: 5'
REAR: 10'
SITE NOTES:
1. THE CONTRACTOR SHALL VERIFY THE LOCATION OF ALL UNDERGROUND
UTILITIES BY CALLING UTILITY LOCATION SERVICE AT 811 THREE (3) DAYS
PRIOR TO CONSTRUCTION.
2. DIMENSIONS SHOWN ARE TO FACE OF CURB, CENTERLINE OF PARKING
STALL OR FACE OF BUILDING UNLESS OTHERWISE NOTED.
3. REFER TO THE ARCHITECTURAL DRAWINGS FOR EXACT BUILDING
DIMENSIONS AND ENTRY/EXIT PORCHES.
4. ASPHALT PAVING SECTIONS SHALL BE CONSTRUCTED PER THE DETAILS.
5. CONCRETE SIDEWALKS SHALL BE CONSTRUCTED WITH 3000 PSI
CONCRETE 4" THICK WITH EXPANSION JOINTS AND SCORING PER DETAIL.
6. THE CONTRACTOR SHALL CONDUCT ALL WORK IN ACCORDANCE WITH
THE LATEST REQUIREMENTS OF THE OCCUPATIONAL SAFETY AND
HEALTH ADMINISTRATION.
7. ALL WORK ON STATE, COUNTY, OR CITY RIGHT-OF-WAY INCLUDING
DRIVEWAY APRONS, WATER AND SEWER TAPS OR ANY OTHER WORK
REQUIRES AN ENCROACHMENT PERMIT FROM THE APPROPRIATE
AGENCY.
8. ALL CURBING TO BE 18" FORMED CONCRETE CURBING PER DETAIL, WITH
3000 PSI CONCRETE.
9. ANY MATERIAL DEMOLISHED AS INDICATED ON THIS PLAN IS TO BE
HAULED OFF-SITE TO AN APPROVED LANDFILL.
10. TRUNCATED DOMES ARE TYPICAL AT ALL HANDICAP RAMPS. HANDICAP
SPACES WILL BE MARKED WITH A FREESTANDING OR WALL MOUNTED
SIGN. SEE DETAIL SHEETS FOR PROPER STRIPING.
C201 C202
SHEET KEY
MATCHLINE. SEE SHEETS
C201 & C202 FOR BLOWUPS
S.C.GRID
UTILITY PROVIDERS:
SEWER - SEPTIC
WATER - CITY OF WALHALLA
POWER - BLUE RIDGE ELECTRIC
TYPICAL LOT
SEPTIC FIELD PER SCDES DESIGN
ADDITIONAL SEPTIC DETAIL ON C250
VARIES
90' OR 100'
SEPTIC
AREA
HOUSE W
DETACHED
GARAGE
W
4
80
60
61
62
63
58
56
57
86
59
87
53
85
84
83
82
81
79
55
54
64
65
78
IPO 1/2" RB BENT
N/F MICHAEL W HUGHES
& DIANN S HUGHES
TM# 177-00-02-053
N/F LOREN S LEE
TM# 177-00-02-023
DB 1587, PG 300
N/F RILEY LECLAIR
& ROXANNE LECLAIR
TM# 177-05-01-027
DB 2838, PG 169
PB B278, PG 7-8
N/F AMANDA G STOKES
TM# 177-05-01-028
DB 2425, PG 150N/F MARIA D D MARTINEZ
TM# 177-05-01-029
DB 2923, PG 193
PB B278, PG 7
N/F PENG CHEN
TM# 177-05-01-030
DB 2293, PG 53
N/F PENG CHEN
TM# 177-05-01-031
DB 2293, PG 53
N/F CHAUGA LLC
TM# 177-05-01-032
DB 1754, PG 20
N/F DIANA EASTWOOD
TM# 177-05-01-033
DB 2857, PG 320
PB B845, PG 2
IPO 1" SR
IPO 3/4" OT
IPO 1" OT
IPO 1" SR
IPO 1/2" RB BENT
IPO 3/4" OT
IPO 1/2" RB
IPO 1/2" RB
IPO 1/2" RB
IPO 1/2" RB
IPO 1/2" RB
IPO 1/2" RB
IPO 1/2" RB
IPO 1/2" RB
IPO 1/2" RB
IPO 1/2" RB
EP
EP
S31°10'40"E185.20'(TIE)
S31°15'10"E190.02'(TIE)
ADJOINER'S
POND
(SUBJECT TO R/W)
IPO 1/2" RB BENT
N30°06'23"E
733.94'
N30°17'51"E
114.22'
N80°00'30"W131.93'
N11°31'32"E242.80'
N15°04'42"W311.45'
291.84'
S50°56'24"W
S31°12'59"E
185.29'
S58°50'15"W
163.71'
S54°37'53"W
140.24' S22°27'45"W
166.20'
L39
L40
L41
L42
L43
L44
L45
L46L47
L48
L49
L50L51
L52
L53
L54
L55L56L57L58L59
L60L61
L62
L63
L64
L=74.53' R=475.00'
N63°14'39"E 74.45'
L65
L66
L67
L68
N53°03'58"E
162.36'
S86°30'18"W
137.69'
N70°25'32"W
202.43'
N70°25'32"W
217.99'
S70°25'32"E232.13'
S70°25'32"E341.17'
S70°25'32"E322.57'
S70°25'32"E305.84'
S70°25'32"E287.25'
S70°25'32"E270.52'
S70°25'32"E251.93'
S64°45'04"E234.62'
S53°50'15"E229.69'
S70°25'32"E
S70°25'32"E483.04'
S70°25'32"E445.35'
S70°25'32"E391.63'
S70°25'32"E385.59'
S70°25'32"E292.88'
S70°25'32"E264.86'
S70°25'32"E252.55'
S70°25'32"E189.40'
N19°34'28"E
110.00'
N19°34'28"E
100.00'
N19°34'28"E
90.00'
N19°34'28"E
100.00'
N19°34'28"E
90.00'
N19°34'28"E
100.00'
N19°34'28"E
90.00'
N19°34'28"E
100.00'
S19°34'28"W
90.00'
S19°34'28"W
100.00'
S19°34'28"W
90.00'
S19°34'28"W
100.00'
S19°34'28"W
90.00'
S19°34'28"W
100.00'
S19°34'28"W
90.00'
S19°34'28"W
100.00'
N31°12'59"W
130.60'
S31°12'59"E178.92'
S19°34'28"W
51.14'
C1C2
C3
C4
C5
C6
S19°34'28"W
38.01'
N19°34'28"E
38.01'
N19°34'28"E
31.14'
N31°12'59"W
45.43'
(35.35')
(32.86')
1 inch = ft.
( IN FEET )
GRAPHIC SCALE
0 50
50
50 20010025
LOCATION MAP NOT TO SCALE
SHEET OF
HORZ. SCALE:
VERT. SCALE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
DATE:
NO.
DATE
www.sitedesign-inc.com
225 ROCKY CREEK ROAD
GREENVILLE, SC 29615
PH: (864) 271-0496
SITE DESIGN, INC.
CIVIL ENGINEERS - SURVEYORS - LANDSCAPE ARCHITECTS
1.2.3.4.5.6.7.8.9.10.THIS DRAWING IS THE PROPERTY OF SITE DESIGN, INC. AND IS
FURNISHED WITH THE CONDITION THAT IT IS NOT TO BE CHANGED
WITHOUT THE WRITTEN AUTHORIZATION OF SITE DESIGN, INC.
FURTHERMORE, THIS DRAWING IS NOT TO BE COPIED, REPRODUCED,
OR USED BY OTHERS EXCEPT AS REQUIRED FOR THE WORK OF THIS
SPECIFIC PROJECT.
© 2023 SITE DESIGN, INC.
U
FI
R ITEC
E
AC
T
A
FO
Z RI
HT
O
I TA
ON
S
H
UT
O
CA
AN
R
LO
I
SITE
DESIGN
INC.
No. C00122
W E
S
N
MELTON RD
OLD WALHALLA HWY
WINSTON WAY
S-37-341
S-37-35
S-37-220
S-37-107
W UNION RD
LINHART RD S-37-573
SITE
HIDDEN FALLS DR
BUFFALO RD
LICENSED PROFESSIONAL ENGINEER
STEPHANIE PO
HLMAN GATES
A
A
IL
RO
N
C
No. 29077UOS
HT
12/16/2024
1" = 50'
N/A
24
HIDDEN FALLS
SUBDIVISION PH 2
MCJ
SPG
12/16/2024
S230651/BASE_SHEETS
MCJ
S.C. REG 29077
C201
6
SITE PLAN
(1 OF 2)
OCONEE COUNTY
SOUTH CAROLINA
DISTINGUISED DESIGN
LLC
THE UTILITIES SHOWN ARE SHOWN FOR THE CONTRACTOR'S CONVENIENCE ONLY.
THERE MAY BE OTHER UTILITIES NOT SHOWN ON THESE PLANS. THE ENGINEER
ASSUMES NO RESPONSIBILITY FOR THE LOCATIONS SHOWN AND IT SHALL BE THE
CONTRACTOR'S RESPONSIBILITY TO VERIFY THE LOCATIONS OF ALL UTILITIES
WITHIN THE LIMITS OF THE WORK. ALL DAMAGE MADE TO EXISTING UTILITIES
BY THE CONTRACTOR SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR.
***CAUTION***
Know what's below.Call before you dig.
SITE DATA
SITE ADDRESS HIDDEN FALLS DRIVE
WEST UNION, SC 29696
OWNER/DEVELOPER DISTINGUISHED DESIGN LLC
535 ST MARK RD
TAYLORS, SC 29687
CONTACT: DAVID HAZEL
864-304-6087
CIVIL ENGINEER SITE DESIGN, INC.
225 ROCKY CREEK ROAD
GREENVILLE, SC 29615
ZONING LRD
LAKE RESIDENTIAL
PROPOSED USE SINGLE FAMILY DETACHED
TAX MAP # TMS# 1770002007, 1770002212,
1770002214
PARCEL AREA 36.4 ACRES
SETBACKS FRONT: 25'
SIDES: 5'
REAR: 10'
C201 C202
SHEET KEY
R140.0'
R160.0'
R25.0'
R25.0'
20.0'
50.0'20-FT ROAD WIDTH WITH 4-FT
SHOULDERS & ROADSIDE
DITCHES
R510.0'
R490.0'
100.0'
100-FT CREEK BUFFER
PARCEL NUMBERING
CONTINUED FROM PHASE 1
S.C.GRID
50.0'
50-FT
UNDISTURBED
BUFFER
5
66
67
68
69
76
77
75
74
72
71
70
73
IPO 5/8" RB
N/F DAVID E ARREDONDO
& MARYLYNN ARREDONDO
TM# 177-01-01-018
DB 2275, PG 334
N/F CHRISWHITNEY LLC
TM# 177-01-01-017
DB 2629, PG 340
N/F SHARON W WOOD
TM# 177-01-02-020
DB 1141, PG 55
N/F JOHN D TOSKO
TM# 177-01-02-019
DB 2205, PG 104
N/F ERIC S BRAMLETT
& KATHY A BRAMLETT
TM# 177-01-02-018
DB 1050, PG 27
PB P45, PG 23
N/F ERIC S BRAMLETT
& KATHY A BRAMLETT
TM# 177-01-02-017
DB 1050, PG 27
N/F JAY N STRAIGHT
TM# 177-01-02-023
DB 2142, PG 288
N/F WILLIAMS THREE LLC
TM# 177-05-01-034
DB 2943, PG 250
PB B278, PG 7-8
N/F VIRGIL C MEYERS JR
& CYNTHIA D MEYERS
TM# 177-05-01-024
DB 1751, PG 219
N/F VIRGIL C MEYERS JR
& CYNTHIA D MEYERS
TM# 177-05-01-025
DB 1854, PG 301
N/F MICHAEL D CORNEY
TM# 177-05-01-026
DB 2782, PG 72
PB B278, PG 7-8
OLD CON MON "DPCO"IPO 5/8" RB
IPO 1/2" RB
@ 44.76'
REF IPO 1/2"
RB @ 59.79'
IPO 1/2" RB
IPO 1/2" OT
IPO 3/4" CT
0.9' ENCROACHMENT
IPO 3/4" CT
IPO 3/4" CT
IPO 1/2" RB
IPO 1/2" RB
IPO 1/2" RB
IPO 1" OT
IPO 1/2" RB
IPO 1/2" RB
IPS 1/2" RB
RIPRAP
IPO 1/2" RB UNDER ROOT
IPO 1/2" RB BENT
DOCK
TETHER
TETHER
FF=834.37
FF=824.18
IPO 1/2" RB
IPO 1/2" RB
IPO 1/2" RB
IPO 1/2" RB
IPO 3/4" OT
IPO 1/2" RB
IPO 3/4" OT
IPO 1" OT
IPO 3/4" OT
DIRT & GRAVEL ROAD
ASPHALT
EP
EP
GRAVEL (TYP)
ADJOINER'S
GRAVEL
1.3' ENCROACHMENT
RAILROAD TIE WALL
BLOCK WALL
PORCH
ASPHALT
STONE WALL
EDGE OF WATER
(TM# 177-00-02-007)
PT (TYP)
BRICK WALL
ARMANDA WAY
LAKE KEOWEE
N57°10'36"E
134.63'
N58°49'34"E
51.49'
N57°56'34"E
115.87'
N57°43'42"E
113.23'
N58°17'18"E
589.22'
N58°43'49"E
100.85'
N56°12'04"E
385.02'
S57°46'32"W
115.26'
S57°52'33"W
274.12'
S57°52'01"W
290.53'
S57°46'32"W
115.26'
S42°29'00"W
235.22'
L5
L6
L7
L8
L9
L10
L11
L12
L13
L14
L15
L16
L17
L18
L19
L20
L21
L22
L23
L24
L25L26L27
L28
L29
L30
L31L32L33L34
L35
L36
L37
L38
L39
229.69'
S44°00'56"E
192.84'
S32°54'15"E176.71'
S31°56'10"E177.27'
S31°56'10"E154.27'
N31°56'10"W
146.25'
N58°03'50"E
78.78'
N32°01'08"W
175.76'
N58°03'41"E
176.59'
N58°03'50"E
160.00'
S31°56'10"E343.81'
S31°56'10"E339.77'
S31°56'10"E413.53'
S31°56'10"E450.56'
S35°22'49"E475.00'
S57°30'13"E475.00'
S70°25'32"E477.97'
N58°03'50"E
112.75'
N58°03'50"E
108.46'
S58°03'50"W
66.76'
S58°03'50"W
90.00'
C7
C8 C9
C10
C11
C12
C13
C14
C15
C16
C17
1 inch = ft.
( IN FEET )
GRAPHIC SCALE
0 50
50
50 20010025
LOCATION MAP NOT TO SCALE
SHEET OF
HORZ. SCALE:
VERT. SCALE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
DATE:
NO.
DATE
www.sitedesign-inc.com
225 ROCKY CREEK ROAD
GREENVILLE, SC 29615
PH: (864) 271-0496
SITE DESIGN, INC.
CIVIL ENGINEERS - SURVEYORS - LANDSCAPE ARCHITECTS
1.2.3.4.5.6.7.8.9.10.THIS DRAWING IS THE PROPERTY OF SITE DESIGN, INC. AND IS
FURNISHED WITH THE CONDITION THAT IT IS NOT TO BE CHANGED
WITHOUT THE WRITTEN AUTHORIZATION OF SITE DESIGN, INC.
FURTHERMORE, THIS DRAWING IS NOT TO BE COPIED, REPRODUCED,
OR USED BY OTHERS EXCEPT AS REQUIRED FOR THE WORK OF THIS
SPECIFIC PROJECT.
© 2023 SITE DESIGN, INC.
U
FI
R ITEC
E
AC
T
A
FO
Z RI
HT
O
I TA
ON
S
H
UT
O
CA
AN
R
LO
I
SITE
DESIGN
INC.
No. C00122
W E
S
N
MELTON RD
OLD WALHALLA HWY
WINSTON WAY
S-37-341
S-37-35
S-37-220
S-37-107
W UNION RD
LINHART RD S-37-573
SITE
HIDDEN FALLS DR
BUFFALO RD
LICENSED PROFESSIONAL ENGINEER
STEPHANIE PO
HLMAN GATES
A
A
IL
RO
N
C
No. 29077UOS
HT
12/16/2024
1" = 50'
N/A
24
HIDDEN FALLS
SUBDIVISION PH 2
MCJ
SPG
12/16/2024
S230651/BASE_SHEETS
MCJ
S.C. REG 29077
C202
7
SITE PLAN
(2 OF 2)
OCONEE COUNTY
SOUTH CAROLINA
DISTINGUISED DESIGN
LLC
THE UTILITIES SHOWN ARE SHOWN FOR THE CONTRACTOR'S CONVENIENCE ONLY.
THERE MAY BE OTHER UTILITIES NOT SHOWN ON THESE PLANS. THE ENGINEER
ASSUMES NO RESPONSIBILITY FOR THE LOCATIONS SHOWN AND IT SHALL BE THE
CONTRACTOR'S RESPONSIBILITY TO VERIFY THE LOCATIONS OF ALL UTILITIES
WITHIN THE LIMITS OF THE WORK. ALL DAMAGE MADE TO EXISTING UTILITIES
BY THE CONTRACTOR SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR.
***CAUTION***
Know what's below.Call before you dig.
SITE DATA
SITE ADDRESS HIDDEN FALLS DRIVE
WEST UNION, SC 29696
OWNER/DEVELOPER DISTINGUISHED DESIGN LLC
535 ST MARK RD
TAYLORS, SC 29687
CONTACT: DAVID HAZEL
864-304-6087
CIVIL ENGINEER SITE DESIGN, INC.
225 ROCKY CREEK ROAD
GREENVILLE, SC 29615
ZONING LRD
LAKE RESIDENTIAL
PROPOSED USE SINGLE FAMILY DETACHED
TAX MAP # TMS# 1770002007, 1770002212,
1770002214
PARCEL AREA 36.4 ACRES
SETBACKS FRONT: 25'
SIDES: 5'
REAR: 10'
C201 C202
SHEET KEY
20-FT ROAD WIDTH
WITH 4-FT SHOULDERS
& ROADSIDE DITCHES
100-FT CREEK BUFFER
124.7'
30.0'
90.0'
30.0'
R25.0'
R40.0'
R63.0'50.0'20.0'
R510.0'
R490.0'
100.0'
S.C.GRID
6
7
8
9
(a)
(b)
Sec. 38-8.6. - Subsequent rezoning.
Subsequent to the initial change of zoning of any parcel or group of parcels following adoption of
these regulations, any individual property owner may make application for rezoning of a parcel(s).
All such rezonings shall be subject to the standards set forth in these regulations and South
Carolina Code of Laws, 1976, as amended.
Notwithstanding any effort to accomplish a prior rezoning, county council may at any time rezone
a parcel or group of parcels pursuant to the goals established in the Oconee County
Comprehensive Plan.
(Ord. No. 2017-25, § 1(Att. A), 12-5-2017)
2/6/25, 11 13 AM Oconee County, SC Code of Ordinances
about blank 1/1
10
1
James Coley
From: James Coley
Sent: Thursday, January 9, 2025 9:40 AM
To: John Pulliam
Subject: RE: 111-24-01-010
Attachments: Ordinance 2011-14.pdf; DOC273.pdf; B717_8.pdf
Not GIS, but I have been working through the history for the parcel(s) this week. I think I understand what happened to
cause the split zoning. Under Ordinance 2011‐14 “C” (page 2 attached) the parcels that went into CCD were 111‐24‐01‐
002 through 111‐24‐01‐009. And 111‐24‐01‐001 went into Lake Residential (Appendix B page 12). I went through the
assessor's records and found the parcel lines from the same time in 2011 (scan attached). The parcel lines match the
split zoning prior to the parcels being combined in 2020 by plat book b717 page 8 (attached), which is when tax map
number 111‐24‐021‐010 was first assigned.
Let me know if you still have questions.
Thanks,
James Coley
Director
Oconee County Planning and Zoning
415 S. Pine Street
Walhalla, SC 29691
Phone: (864) 638.4218
CONFIDENTIALITY NOTICE:
All e-mail correspondence to and from this address may be subject to public disclosure under
the South Carolina Freedom of Information Act (FOIA). This correspondence is intended exclusively for the individual or
entity to which it is addressed, and may contain information that is proprietary, privileged, confidential or otherwise legally
exempt from disclosure.
If you are not the intended recipient, you may not read, use, copy, or distribute this e‐mail message or its attachments. If
you believe you have received this e‐mail message in error, please contact the sender by reply e‐mail or telephone
immediately and destroy all copies of the original message.
From: John Pulliam
Sent: Thursday, January 9, 2025 9:19 AM
11
12
13
14
15
16
17
Book: B717 Page: 8 Page: 1 of 1
18
19
Note S.C. Code Ann. § 6-29-1200:
(B) A commission may, after reasonable notice through a newspaper having
general circulation in which the commission is created and exists, change the name
of a street or road within the boundary of its territorial jurisdiction:
(1) when there is duplication of names or other conditions which tend to confuse
the traveling public or the delivery of mail, orders, or messages;
(2) when it is found that a change may simplify marking or giving of directions to
persons seeking to locate addresses; or
(3) upon any other good and just reason that may appear to the commission.
(C) On the name being changed, after reasonable opportunity for a public hearing,
the planning commission shall issue its certificate designating the change, which
must be recorded in the office of the register of deeds or clerk of court, and the
name changed and certified is the legal name of the street or road.
20
21
22
(1)
a.
b.
1.
2.
3.
4.
5.
(2)
a.
Sec. 38-9.3. - Dimensional requirements: General provisions and exceptions.
In addition to the dimensional requirements listed below and district dimensional requirements, further
dimensional requirements may be set forth in
article 5 for those uses listed as conditional. The control free
district shall be exempt from the provisions of this section except provisions listed under item (2), setbacks.
Lot size and configuration.
Public utilities and government. Public utilities and government uses shall not be subject
to the minimum lot size requirements, but shall meet the setback requirements.
Flag lots. Flag lots may be permitted under the following conditions:
The maximum length of the pole of a flag lot shall be 300 feet.
The minimum width of the pole of a flag lot shall be 22 feet, and the maximum width
of the pole of a flag lot shall be 40 feet.
The front setback shall be measured from where the flag portion of the flag lot meets
the district minimum width requirements.
The pole portion of a flag lot shall not be used to calculate width, or setbacks of the
lot, or to provide off-street parking.
There shall be no more than one flag lot per each four lots, per subdivision or
development.
Flag lot illustration:
Setbacks.
The required front, side, and rear yards for individual lots shall be measured inward
toward the center of said lot from all points along the respective front, side, and rear
property lines of the lot, or from the road right-of-way if applicable. Once the yard areas
of a given lot have been established, the remaining area of the lot which is not included in
any required front, side, or rear lot shall be known as the "buildable" area within which
the approved structure(s) shall be placed.
2/25/25, 12:29 PM Oconee County, SC Code of Ordinances
about:blank 1/3
23
b.
c.
d.
e.
f.
g.
h.
i.
Where a road right-of-way projects over a property line, the setback shall be measured
from the road right-of-way line.
Corner lots shall be considered to have two fronts and shall meet the front setback for the
district.
Front yard setbacks for double frontage lots shall be provided for both streets upon which
the lot has frontage, and any accessory use(s) shall be prohibited from the required front
yard setback of the street upon which the principal building fronts.
For lots not meeting the required minimum lot width for the respective district at the front
property line or road right-of-way, as applicable, the setback shall be measured such that
the distance from the front property line or road right-of-way, as applicable, shall
nonetheless be included in the measurement for the required setback. The buildable area
shall not, however, include any area where the minimum lot width is not met. This
provision is meant to apply to irregularly shaped lots, as generally determined by their
existing lot width and configuration in relation to the district minimum lot width. This
provision does not apply to flag lots. See
section 38-9.3(1)(b) for flag lot provisions.
Road design and encroachment criteria is governed by the standards in chapter 26, of the
Oconee County Code of Ordinances, as amended.
Any garage door shall be set back a minimum of 20 feet from the property line that it
faces so that vehicles may be parked in the driveway without encroaching into the right-
of-way. If the district setback is greater than 20 feet, then the more restrictive setback
shall prevail.
The side and rear setbacks in the CCD and HCD shall not apply to the shared property line
of attached buildings.
2/25/25, 12:29 PM Oconee County, SC Code of Ordinances
about:blank 2/3
24
j.
The space in any required yard shall be open and unobstructed except for the ordinary projections of
window sills, cornices, eaves, window air conditioning units, and other architectural features, provided that
such features shall project no more than two feet into any required yard.
Steps and heating and cooling units may project into a required yard a distance not to
exceed five feet but no closer than five feet of a property line. Fences, freestanding walls,
hedges, and septic lines may be located in any setback, so long as they remain on the
property.
(Ord. No. 2012-14, § 1, 5-15-2012; Ord. No. 2018-19, § 1(Att. A), 8-21-2018; Ord. No. 2024-23, §§ 1, 2(Exh. A),
10-15-2024)
2/25/25, 12:29 PM Oconee County, SC Code of Ordinances
about:blank 3/3
25