RecordWell Data

Backup Material

Oconee County · Oconee County · meeting of Mar 3, 2025 · Other

Open the original document More from Oconee County

Text

Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.

COMMISSION MEMBERS Mike Johnson, At-Large David Nix, District 2 Teresa Spicer, District 1 Brit Adams, District 3 Joe Fravel, District 4 Jake Marcengill, District 5 Mickey Haney, At-Large AGENDA 6:00 pm, Monday, March 3, 2025 Council Chambers - Oconee County 415 S Pine St, Walhalla SC 29691 1. Call to Order 2. Invocation 3. Pledge of Allegiance 4. Approval of minutes from February 3, 2025 5. Public Comment for Non-Agenda Items (4 minutes per person) 6. Commission Member Comments 7. Planning Staff Comments 8. Discussion and recommendation to council regarding subsequent rezoning of parcel 111-24-01-010 from split zoning in both LRD and CCD to all in CCD. a. Public Comment b. Discussion/ vote 9. Public Hearing- The renaming of Jefferson Place to Cherry Tree Place or Rose Bush Lane, consistent with S.C. Code § 6-29-1200 and the Oconee County Road Naming and Addressing Policy. a. Discussion/ Vote 10. Discussion regarding amending Chapter 38 article 9, Sec 38-9.3 Dimensional requirements: general provisions and exceptions 2. Setbacks, j. “Steps and heating and cooling units may project into a required yard a distance not to exceed five feet but no closer than five feet of a property line. Fences, freestanding walls, hedges, and septic lines may be located in any setback, so long as they remain on the property.” a. Public Comment b. Discussion/ vote 11. Adjourn 1 COMMISSION MEMBERS Mike Johnson, Chairman, At-Large David Nix, Vice Chair, District 2 Teresa Spicer, District 1 Brit Adams, District 3 Joe Fravel, District 4 Jake Marcengill, District 5 Mickey Haney, At-Large STAFF James Coley Elise Dunaway MINUTES 6:00 pm, Monday, February 3, 2025 Council Chambers - Oconee County 415 S. Pine St, Walhalla SC 29691 1. Call to Order – Mr. Johnson called the meeting to order at 6:00 PM. 2. Invocation was led by Mr. Root. 3. Pledge of Allegiance was led by Mr. Haney. 4. Approval of minutes from January 6, 2025 – Mr. Adams made a motion to approve the minutes; Seconded by Mr. Nix. Approved Unanimously. 5. Election of Officers Mr. Nix nominated Mr. Johnson as Chairman of the Planning Commission. Approved unanimously. Mr. Haney nominated Mr. Nix as Vice Chairman of the Planning Commission. Approved Unanimously. Mr. Johnson nominated Mr. Coley as Secretary of the Planning Commission. Approved Unanimously. 6. Public Comment for Non-Agenda Items (4 minutes per person): Mr. Tom Markvoich voiced his opinion regarding retaining walls within the setbacks. 7. Commission Member Comments: Mr. Nix welcomed Mr. Fravel and Mr. Marcengill to the Planning Commission. Mr. Haney thanked Mr. Markovich for attending the meeting and requested the public to attend meetings more often. Mr. Johnson hopes to continue moving forward in the coming year and continue to make improvements where needed in Oconee County. 2 8. Discussion regarding the Scenic Highway Ordinance and potential changes or amendments. a. Public Comment b. Discussion/ vote Mr. Nix made a motion to approve the ordinance as written with the included amendment; Seconded by Mr. Haney. Approved Unanimously. Mr. Johnson made an amendment to the motion that in the application Mr. Root include that the applicant is to be contacted by the county if complaints are being received and include a 45-day response period; Seconded by Mr. Adams. Approve Unanimously. 9. Adjourn – the meeting was adjourned at 6:24 PM. 3 80 60 61 62 63 58 56 57 86 59 87 53 85 84 83 82 81 79 55 54 64 65 66 67 68 69 7678 77 75 74 72 71 70 73 IPO 1/2" RB IPO 5/8" RB OLD RR SPIKE IPO 1/2" RB IPO 1/2" RB BENT IPO 1/2" RB BENT OLD CON MON "DPCO"IPO 5/8" RB IPO 1/2" RB @ 44.76' REF IPO 1/2" RB @ 59.79' IPO 1/2" RB IPO 1/2" OT IPO 3/4" CT IPO 1" SR FF=833.98 DECKCANOPY 0.9' ENCROACHMENT IPO 3/4" CT IPO 3/4" CT IPO 1/2" RB IPO 1/2" RB IPO 1/2" RB IPO 1" OT IPO 1/2" RB IPO 1/2" RB IPS 1/2" RB IPO 1/2" RB UNDER ROOT IPO 1/2" RB BENT DOCK TETHER TETHER FF=834.37FF=824.18IPO 1/2" RB IPO 1/2" RB IPO 1/2" RB IPO 1/2" RB IPO 3/4" OT IPO 1/2" RB IPO 3/4" OT IPO 1" OT IPO 3/4" OT IPO 1" SR IPO 3/4" OT IPO 1" OT IPO 1" SR IPO 1/2" RB BENT IPO 3/4" OT IPO 1/2" RB IPO 1/2" RB IPO 1/2" RB IPO 1/2" RB IPO 3/4" OT BENTOLD SUB READING IPO 1/2" RB OLD NAIL IN CAP IPO 1/2" RB IPO 1/2" RB IPO 1/2" RB IPO 1/2" RB IPO 1/2" RB IPO 1/2" RB IPO 1/2" RB IPO 1/2" RB IPO 1/2" RB ASPHALT EP EP EP EP EP EP EP ADJOINER'S POND ASPHALT EPEP 1.3' ENCROACHMENT RAILROAD TIE WALL BLOCK WALL PORCH ASPHALT STONE WALL EDGE OF WATER (TM# 177-00-02-007) PT (TYP) PT (TYP) BRICK WALL ARMANDA WAY BROWN WOOD DRIVE BUFFALO ROAD HIDDEN FALLS DRIVE LAKE KEOWEE (SUBJECT TO R/W) (SUBJECT TO R/W) IPO 1/2" RB BENT (INCLUDES ANY AND ALL R/W) 1 inch = ft. ( IN FEET ) GRAPHIC SCALE 0 125 125 125 50025063 LOCATION MAP NOT TO SCALE SHEET OF HORZ. SCALE: VERT. SCALE: DESIGNED BY: DRAWN BY: CHECKED BY: DATE: NO. DATE www.sitedesign-inc.com 225 ROCKY CREEK ROAD GREENVILLE, SC 29615 PH: (864) 271-0496 SITE DESIGN, INC. CIVIL ENGINEERS - SURVEYORS - LANDSCAPE ARCHITECTS 1.2.3.4.5.6.7.8.9.10.THIS DRAWING IS THE PROPERTY OF SITE DESIGN, INC. AND IS FURNISHED WITH THE CONDITION THAT IT IS NOT TO BE CHANGED WITHOUT THE WRITTEN AUTHORIZATION OF SITE DESIGN, INC. FURTHERMORE, THIS DRAWING IS NOT TO BE COPIED, REPRODUCED, OR USED BY OTHERS EXCEPT AS REQUIRED FOR THE WORK OF THIS SPECIFIC PROJECT. © 2023 SITE DESIGN, INC. U FI R ITEC E AC T A FO Z RI HT O I TA ON S H UT O CA AN R LO I SITE DESIGN INC. No. C00122 W E S N MELTON RD OLD WALHALLA HWY WINSTON WAY S-37-341 S-37-35 S-37-220 S-37-107 W UNION RD LINHART RD S-37-573 SITE HIDDEN FALLS DR BUFFALO RD LICENSED PROFESSIONAL ENGINEER STEPHANIE PO HLMAN GATES A A IL RO N C No. 29077UOS HT 12/16/2024 1" = 125' N/A 24 HIDDEN FALLS SUBDIVISION PH 2 MCJ SPG 12/16/2024 S230651/BASE_SHEETS MCJ S.C. REG 29077 C200 5 SITE PLAN OVERALL OCONEE COUNTY SOUTH CAROLINA DISTINGUISED DESIGN LLC THE UTILITIES SHOWN ARE SHOWN FOR THE CONTRACTOR'S CONVENIENCE ONLY. THERE MAY BE OTHER UTILITIES NOT SHOWN ON THESE PLANS. THE ENGINEER ASSUMES NO RESPONSIBILITY FOR THE LOCATIONS SHOWN AND IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE LOCATIONS OF ALL UTILITIES WITHIN THE LIMITS OF THE WORK. ALL DAMAGE MADE TO EXISTING UTILITIES BY THE CONTRACTOR SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR. ***CAUTION*** Know what's below.Call before you dig. STORMWATER FLOW TRAFFIC FLOW STORMWATER FLOW TRAFFIC FLOWIE INVERT ELEVATION W ROOF DRAIN - NEW WATER - NEW CONTOURS - FINISHED GRADE CHAIN LINK FENCE (EXISTING) CHAIN LINK FENCE (PROPOSED) (678) LINETYPES UNDERGROUND TEL SANITARY SEWER - EXIST. WOOD FENCE CABLE TV FIBER OPTIC UNDERGROUND POWER OVERHEAD POWER GAS LINE W UGT UGP SD SS SS RD OHT OHP GAS FM FOC X X CTV FORCE MAIN STORM SEWER - NEW STORM SEWER - EXIST. SANITARY SEWER - NEW CONTOURS - EXIST. GRADE680 SILT FENCE OVERHEAD TELEPHONE WATER LINE - EXIST. LEGEND SF NPDES LIMITS OF DISTURBANCE CO CLEAN OUT ELECTRIC METER TELEPHONE MANHOLE VCP VITRIFIED CLAY PIPE REINFORCED CONC PIPERCP CMP CORRUGATED METAL PIPE STORM DRAINSD SANITARY SEWERSS PP POWER POLE WM WV WATER METER WATER VALVE TELEPHONE PEDESTALTEL CATCH BASIN DROP INLET ELEVATION GM GAS VALVE FIRE HYDRANT GAS METER ELEC TRANS CB DI GV DYH D S SD MANHOLE SS MANHOLE LIGHT POLE SDMH SSMH LP CL BL EP DE CT N&C IPS IPO R/W RB OT SSE SS EASEMENT RIGHT OF WAY OPEN TOP REBAR NAIL & CAP IRON PIN SET- EDGE OF PAVEMENT IRON PIN OLD- DRAINAGE EASEMENT CENTERLINE CRIMP TOP BUILDING LINE GP GUY ANCHOR EM TOP/BOTTOM WALLTW/BW TOP/BOTTOM CURBTC/BC TTMH PIV POST INDICATOR VALVE90.0x CABLE TV PEDESTALCATV GREASE TRAP MANHOLEGT FFE FINISHED FLOOR ELEVATION FG FINISHED GRADE The contractor shall coordinate with the engineer of record for a digital staking plan to establish complete horizontal and vertical control. The contractor is responsible for survey stakeout of all improvements. Discrepancies between the plans, construction stakes, and field conditions shall be reported to the engineer of record immediately for resolution prior to installation of proposed improvements.” TOTAL SITE DISTURBANCE: 24.1 ACRES SITE DATA SITE ADDRESS HIDDEN FALLS DRIVE WEST UNION, SC 29696 OWNER/DEVELOPER DISTINGUISHED DESIGN LLC 535 ST MARK RD TAYLORS, SC 29687 CONTACT: DAVID HAZEL 864-304-6087 CIVIL ENGINEER SITE DESIGN, INC. 225 ROCKY CREEK ROAD GREENVILLE, SC 29615 ZONING LRD LAKE RESIDENTIAL PROPOSED USE SINGLE FAMILY DETACHED TAX MAP # TMS# 1770002007, 1770002212, 1770002214 PARCEL AREA 36.4 ACRES SETBACKS FRONT: 25' SIDES: 5' REAR: 10' SITE NOTES: 1. THE CONTRACTOR SHALL VERIFY THE LOCATION OF ALL UNDERGROUND UTILITIES BY CALLING UTILITY LOCATION SERVICE AT 811 THREE (3) DAYS PRIOR TO CONSTRUCTION. 2. DIMENSIONS SHOWN ARE TO FACE OF CURB, CENTERLINE OF PARKING STALL OR FACE OF BUILDING UNLESS OTHERWISE NOTED. 3. REFER TO THE ARCHITECTURAL DRAWINGS FOR EXACT BUILDING DIMENSIONS AND ENTRY/EXIT PORCHES. 4. ASPHALT PAVING SECTIONS SHALL BE CONSTRUCTED PER THE DETAILS. 5. CONCRETE SIDEWALKS SHALL BE CONSTRUCTED WITH 3000 PSI CONCRETE 4" THICK WITH EXPANSION JOINTS AND SCORING PER DETAIL. 6. THE CONTRACTOR SHALL CONDUCT ALL WORK IN ACCORDANCE WITH THE LATEST REQUIREMENTS OF THE OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION. 7. ALL WORK ON STATE, COUNTY, OR CITY RIGHT-OF-WAY INCLUDING DRIVEWAY APRONS, WATER AND SEWER TAPS OR ANY OTHER WORK REQUIRES AN ENCROACHMENT PERMIT FROM THE APPROPRIATE AGENCY. 8. ALL CURBING TO BE 18" FORMED CONCRETE CURBING PER DETAIL, WITH 3000 PSI CONCRETE. 9. ANY MATERIAL DEMOLISHED AS INDICATED ON THIS PLAN IS TO BE HAULED OFF-SITE TO AN APPROVED LANDFILL. 10. TRUNCATED DOMES ARE TYPICAL AT ALL HANDICAP RAMPS. HANDICAP SPACES WILL BE MARKED WITH A FREESTANDING OR WALL MOUNTED SIGN. SEE DETAIL SHEETS FOR PROPER STRIPING. C201 C202 SHEET KEY MATCHLINE. SEE SHEETS C201 & C202 FOR BLOWUPS S.C.GRID UTILITY PROVIDERS: SEWER - SEPTIC WATER - CITY OF WALHALLA POWER - BLUE RIDGE ELECTRIC TYPICAL LOT SEPTIC FIELD PER SCDES DESIGN ADDITIONAL SEPTIC DETAIL ON C250 VARIES 90' OR 100' SEPTIC AREA HOUSE W DETACHED GARAGE W 4 80 60 61 62 63 58 56 57 86 59 87 53 85 84 83 82 81 79 55 54 64 65 78 IPO 1/2" RB BENT N/F MICHAEL W HUGHES & DIANN S HUGHES TM# 177-00-02-053 N/F LOREN S LEE TM# 177-00-02-023 DB 1587, PG 300 N/F RILEY LECLAIR & ROXANNE LECLAIR TM# 177-05-01-027 DB 2838, PG 169 PB B278, PG 7-8 N/F AMANDA G STOKES TM# 177-05-01-028 DB 2425, PG 150N/F MARIA D D MARTINEZ TM# 177-05-01-029 DB 2923, PG 193 PB B278, PG 7 N/F PENG CHEN TM# 177-05-01-030 DB 2293, PG 53 N/F PENG CHEN TM# 177-05-01-031 DB 2293, PG 53 N/F CHAUGA LLC TM# 177-05-01-032 DB 1754, PG 20 N/F DIANA EASTWOOD TM# 177-05-01-033 DB 2857, PG 320 PB B845, PG 2 IPO 1" SR IPO 3/4" OT IPO 1" OT IPO 1" SR IPO 1/2" RB BENT IPO 3/4" OT IPO 1/2" RB IPO 1/2" RB IPO 1/2" RB IPO 1/2" RB IPO 1/2" RB IPO 1/2" RB IPO 1/2" RB IPO 1/2" RB IPO 1/2" RB IPO 1/2" RB EP EP S31°10'40"E185.20'(TIE) S31°15'10"E190.02'(TIE) ADJOINER'S POND (SUBJECT TO R/W) IPO 1/2" RB BENT N30°06'23"E 733.94' N30°17'51"E 114.22' N80°00'30"W131.93' N11°31'32"E242.80' N15°04'42"W311.45' 291.84' S50°56'24"W S31°12'59"E 185.29' S58°50'15"W 163.71' S54°37'53"W 140.24' S22°27'45"W 166.20' L39 L40 L41 L42 L43 L44 L45 L46L47 L48 L49 L50L51 L52 L53 L54 L55L56L57L58L59 L60L61 L62 L63 L64 L=74.53' R=475.00' N63°14'39"E 74.45' L65 L66 L67 L68 N53°03'58"E 162.36' S86°30'18"W 137.69' N70°25'32"W 202.43' N70°25'32"W 217.99' S70°25'32"E232.13' S70°25'32"E341.17' S70°25'32"E322.57' S70°25'32"E305.84' S70°25'32"E287.25' S70°25'32"E270.52' S70°25'32"E251.93' S64°45'04"E234.62' S53°50'15"E229.69' S70°25'32"E S70°25'32"E483.04' S70°25'32"E445.35' S70°25'32"E391.63' S70°25'32"E385.59' S70°25'32"E292.88' S70°25'32"E264.86' S70°25'32"E252.55' S70°25'32"E189.40' N19°34'28"E 110.00' N19°34'28"E 100.00' N19°34'28"E 90.00' N19°34'28"E 100.00' N19°34'28"E 90.00' N19°34'28"E 100.00' N19°34'28"E 90.00' N19°34'28"E 100.00' S19°34'28"W 90.00' S19°34'28"W 100.00' S19°34'28"W 90.00' S19°34'28"W 100.00' S19°34'28"W 90.00' S19°34'28"W 100.00' S19°34'28"W 90.00' S19°34'28"W 100.00' N31°12'59"W 130.60' S31°12'59"E178.92' S19°34'28"W 51.14' C1C2 C3 C4 C5 C6 S19°34'28"W 38.01' N19°34'28"E 38.01' N19°34'28"E 31.14' N31°12'59"W 45.43' (35.35') (32.86') 1 inch = ft. ( IN FEET ) GRAPHIC SCALE 0 50 50 50 20010025 LOCATION MAP NOT TO SCALE SHEET OF HORZ. SCALE: VERT. SCALE: DESIGNED BY: DRAWN BY: CHECKED BY: DATE: NO. DATE www.sitedesign-inc.com 225 ROCKY CREEK ROAD GREENVILLE, SC 29615 PH: (864) 271-0496 SITE DESIGN, INC. CIVIL ENGINEERS - SURVEYORS - LANDSCAPE ARCHITECTS 1.2.3.4.5.6.7.8.9.10.THIS DRAWING IS THE PROPERTY OF SITE DESIGN, INC. AND IS FURNISHED WITH THE CONDITION THAT IT IS NOT TO BE CHANGED WITHOUT THE WRITTEN AUTHORIZATION OF SITE DESIGN, INC. FURTHERMORE, THIS DRAWING IS NOT TO BE COPIED, REPRODUCED, OR USED BY OTHERS EXCEPT AS REQUIRED FOR THE WORK OF THIS SPECIFIC PROJECT. © 2023 SITE DESIGN, INC. U FI R ITEC E AC T A FO Z RI HT O I TA ON S H UT O CA AN R LO I SITE DESIGN INC. No. C00122 W E S N MELTON RD OLD WALHALLA HWY WINSTON WAY S-37-341 S-37-35 S-37-220 S-37-107 W UNION RD LINHART RD S-37-573 SITE HIDDEN FALLS DR BUFFALO RD LICENSED PROFESSIONAL ENGINEER STEPHANIE PO HLMAN GATES A A IL RO N C No. 29077UOS HT 12/16/2024 1" = 50' N/A 24 HIDDEN FALLS SUBDIVISION PH 2 MCJ SPG 12/16/2024 S230651/BASE_SHEETS MCJ S.C. REG 29077 C201 6 SITE PLAN (1 OF 2) OCONEE COUNTY SOUTH CAROLINA DISTINGUISED DESIGN LLC THE UTILITIES SHOWN ARE SHOWN FOR THE CONTRACTOR'S CONVENIENCE ONLY. THERE MAY BE OTHER UTILITIES NOT SHOWN ON THESE PLANS. THE ENGINEER ASSUMES NO RESPONSIBILITY FOR THE LOCATIONS SHOWN AND IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE LOCATIONS OF ALL UTILITIES WITHIN THE LIMITS OF THE WORK. ALL DAMAGE MADE TO EXISTING UTILITIES BY THE CONTRACTOR SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR. ***CAUTION*** Know what's below.Call before you dig. SITE DATA SITE ADDRESS HIDDEN FALLS DRIVE WEST UNION, SC 29696 OWNER/DEVELOPER DISTINGUISHED DESIGN LLC 535 ST MARK RD TAYLORS, SC 29687 CONTACT: DAVID HAZEL 864-304-6087 CIVIL ENGINEER SITE DESIGN, INC. 225 ROCKY CREEK ROAD GREENVILLE, SC 29615 ZONING LRD LAKE RESIDENTIAL PROPOSED USE SINGLE FAMILY DETACHED TAX MAP # TMS# 1770002007, 1770002212, 1770002214 PARCEL AREA 36.4 ACRES SETBACKS FRONT: 25' SIDES: 5' REAR: 10' C201 C202 SHEET KEY R140.0' R160.0' R25.0' R25.0' 20.0' 50.0'20-FT ROAD WIDTH WITH 4-FT SHOULDERS & ROADSIDE DITCHES R510.0' R490.0' 100.0' 100-FT CREEK BUFFER PARCEL NUMBERING CONTINUED FROM PHASE 1 S.C.GRID 50.0' 50-FT UNDISTURBED BUFFER 5 66 67 68 69 76 77 75 74 72 71 70 73 IPO 5/8" RB N/F DAVID E ARREDONDO & MARYLYNN ARREDONDO TM# 177-01-01-018 DB 2275, PG 334 N/F CHRISWHITNEY LLC TM# 177-01-01-017 DB 2629, PG 340 N/F SHARON W WOOD TM# 177-01-02-020 DB 1141, PG 55 N/F JOHN D TOSKO TM# 177-01-02-019 DB 2205, PG 104 N/F ERIC S BRAMLETT & KATHY A BRAMLETT TM# 177-01-02-018 DB 1050, PG 27 PB P45, PG 23 N/F ERIC S BRAMLETT & KATHY A BRAMLETT TM# 177-01-02-017 DB 1050, PG 27 N/F JAY N STRAIGHT TM# 177-01-02-023 DB 2142, PG 288 N/F WILLIAMS THREE LLC TM# 177-05-01-034 DB 2943, PG 250 PB B278, PG 7-8 N/F VIRGIL C MEYERS JR & CYNTHIA D MEYERS TM# 177-05-01-024 DB 1751, PG 219 N/F VIRGIL C MEYERS JR & CYNTHIA D MEYERS TM# 177-05-01-025 DB 1854, PG 301 N/F MICHAEL D CORNEY TM# 177-05-01-026 DB 2782, PG 72 PB B278, PG 7-8 OLD CON MON "DPCO"IPO 5/8" RB IPO 1/2" RB @ 44.76' REF IPO 1/2" RB @ 59.79' IPO 1/2" RB IPO 1/2" OT IPO 3/4" CT 0.9' ENCROACHMENT IPO 3/4" CT IPO 3/4" CT IPO 1/2" RB IPO 1/2" RB IPO 1/2" RB IPO 1" OT IPO 1/2" RB IPO 1/2" RB IPS 1/2" RB RIPRAP IPO 1/2" RB UNDER ROOT IPO 1/2" RB BENT DOCK TETHER TETHER FF=834.37 FF=824.18 IPO 1/2" RB IPO 1/2" RB IPO 1/2" RB IPO 1/2" RB IPO 3/4" OT IPO 1/2" RB IPO 3/4" OT IPO 1" OT IPO 3/4" OT DIRT & GRAVEL ROAD ASPHALT EP EP GRAVEL (TYP) ADJOINER'S GRAVEL 1.3' ENCROACHMENT RAILROAD TIE WALL BLOCK WALL PORCH ASPHALT STONE WALL EDGE OF WATER (TM# 177-00-02-007) PT (TYP) BRICK WALL ARMANDA WAY LAKE KEOWEE N57°10'36"E 134.63' N58°49'34"E 51.49' N57°56'34"E 115.87' N57°43'42"E 113.23' N58°17'18"E 589.22' N58°43'49"E 100.85' N56°12'04"E 385.02' S57°46'32"W 115.26' S57°52'33"W 274.12' S57°52'01"W 290.53' S57°46'32"W 115.26' S42°29'00"W 235.22' L5 L6 L7 L8 L9 L10 L11 L12 L13 L14 L15 L16 L17 L18 L19 L20 L21 L22 L23 L24 L25L26L27 L28 L29 L30 L31L32L33L34 L35 L36 L37 L38 L39 229.69' S44°00'56"E 192.84' S32°54'15"E176.71' S31°56'10"E177.27' S31°56'10"E154.27' N31°56'10"W 146.25' N58°03'50"E 78.78' N32°01'08"W 175.76' N58°03'41"E 176.59' N58°03'50"E 160.00' S31°56'10"E343.81' S31°56'10"E339.77' S31°56'10"E413.53' S31°56'10"E450.56' S35°22'49"E475.00' S57°30'13"E475.00' S70°25'32"E477.97' N58°03'50"E 112.75' N58°03'50"E 108.46' S58°03'50"W 66.76' S58°03'50"W 90.00' C7 C8 C9 C10 C11 C12 C13 C14 C15 C16 C17 1 inch = ft. ( IN FEET ) GRAPHIC SCALE 0 50 50 50 20010025 LOCATION MAP NOT TO SCALE SHEET OF HORZ. SCALE: VERT. SCALE: DESIGNED BY: DRAWN BY: CHECKED BY: DATE: NO. DATE www.sitedesign-inc.com 225 ROCKY CREEK ROAD GREENVILLE, SC 29615 PH: (864) 271-0496 SITE DESIGN, INC. CIVIL ENGINEERS - SURVEYORS - LANDSCAPE ARCHITECTS 1.2.3.4.5.6.7.8.9.10.THIS DRAWING IS THE PROPERTY OF SITE DESIGN, INC. AND IS FURNISHED WITH THE CONDITION THAT IT IS NOT TO BE CHANGED WITHOUT THE WRITTEN AUTHORIZATION OF SITE DESIGN, INC. FURTHERMORE, THIS DRAWING IS NOT TO BE COPIED, REPRODUCED, OR USED BY OTHERS EXCEPT AS REQUIRED FOR THE WORK OF THIS SPECIFIC PROJECT. © 2023 SITE DESIGN, INC. U FI R ITEC E AC T A FO Z RI HT O I TA ON S H UT O CA AN R LO I SITE DESIGN INC. No. C00122 W E S N MELTON RD OLD WALHALLA HWY WINSTON WAY S-37-341 S-37-35 S-37-220 S-37-107 W UNION RD LINHART RD S-37-573 SITE HIDDEN FALLS DR BUFFALO RD LICENSED PROFESSIONAL ENGINEER STEPHANIE PO HLMAN GATES A A IL RO N C No. 29077UOS HT 12/16/2024 1" = 50' N/A 24 HIDDEN FALLS SUBDIVISION PH 2 MCJ SPG 12/16/2024 S230651/BASE_SHEETS MCJ S.C. REG 29077 C202 7 SITE PLAN (2 OF 2) OCONEE COUNTY SOUTH CAROLINA DISTINGUISED DESIGN LLC THE UTILITIES SHOWN ARE SHOWN FOR THE CONTRACTOR'S CONVENIENCE ONLY. THERE MAY BE OTHER UTILITIES NOT SHOWN ON THESE PLANS. THE ENGINEER ASSUMES NO RESPONSIBILITY FOR THE LOCATIONS SHOWN AND IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE LOCATIONS OF ALL UTILITIES WITHIN THE LIMITS OF THE WORK. ALL DAMAGE MADE TO EXISTING UTILITIES BY THE CONTRACTOR SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR. ***CAUTION*** Know what's below.Call before you dig. SITE DATA SITE ADDRESS HIDDEN FALLS DRIVE WEST UNION, SC 29696 OWNER/DEVELOPER DISTINGUISHED DESIGN LLC 535 ST MARK RD TAYLORS, SC 29687 CONTACT: DAVID HAZEL 864-304-6087 CIVIL ENGINEER SITE DESIGN, INC. 225 ROCKY CREEK ROAD GREENVILLE, SC 29615 ZONING LRD LAKE RESIDENTIAL PROPOSED USE SINGLE FAMILY DETACHED TAX MAP # TMS# 1770002007, 1770002212, 1770002214 PARCEL AREA 36.4 ACRES SETBACKS FRONT: 25' SIDES: 5' REAR: 10' C201 C202 SHEET KEY 20-FT ROAD WIDTH WITH 4-FT SHOULDERS & ROADSIDE DITCHES 100-FT CREEK BUFFER 124.7' 30.0' 90.0' 30.0' R25.0' R40.0' R63.0'50.0'20.0' R510.0' R490.0' 100.0' S.C.GRID 6 7 8 9 (a) (b) Sec. 38-8.6. - Subsequent rezoning. Subsequent to the initial change of zoning of any parcel or group of parcels following adoption of these regulations, any individual property owner may make application for rezoning of a parcel(s). All such rezonings shall be subject to the standards set forth in these regulations and South Carolina Code of Laws, 1976, as amended. Notwithstanding any effort to accomplish a prior rezoning, county council may at any time rezone a parcel or group of parcels pursuant to the goals established in the Oconee County Comprehensive Plan. (Ord. No. 2017-25, § 1(Att. A), 12-5-2017) 2/6/25, 11 13 AM Oconee County, SC Code of Ordinances about blank 1/1 10 1 James Coley From: James Coley Sent: Thursday, January 9, 2025 9:40 AM To: John Pulliam Subject: RE: 111-24-01-010 Attachments: Ordinance 2011-14.pdf; DOC273.pdf; B717_8.pdf Not GIS, but I have been working through the history for the parcel(s) this week. I think I understand what happened to  cause the split zoning. Under Ordinance 2011‐14 “C” (page 2 attached) the parcels that went into CCD were 111‐24‐01‐ 002 through 111‐24‐01‐009. And 111‐24‐01‐001 went into Lake Residential (Appendix B page 12). I went through the  assessor's records and found the parcel lines from the same time in 2011 (scan attached). The parcel lines match the  split zoning prior to the parcels being combined in 2020 by plat book b717 page 8 (attached), which is when tax map  number 111‐24‐021‐010 was first assigned.     Let me know if you still have questions.    Thanks,       James Coley  Director  Oconee County Planning and Zoning  415 S. Pine Street  Walhalla, SC 29691  Phone: (864) 638.4218      CONFIDENTIALITY NOTICE:   All e-mail correspondence to and from this address may be subject to public disclosure under the South Carolina Freedom of Information Act (FOIA). This correspondence is intended exclusively for the individual or entity to which it is addressed, and may contain information that is proprietary, privileged, confidential or otherwise legally exempt from disclosure.  If you are not the intended recipient, you may not read, use, copy, or distribute this e‐mail message or its attachments. If  you believe you have received this e‐mail message in error, please contact the sender by reply e‐mail or telephone  immediately and destroy all copies of the original message.        From: John Pulliam     Sent: Thursday, January 9, 2025 9:19 AM  11 12 13 14 15 16 17 Book: B717 Page: 8 Page: 1 of 1 18 19 Note S.C. Code Ann. § 6-29-1200: (B) A commission may, after reasonable notice through a newspaper having general circulation in which the commission is created and exists, change the name of a street or road within the boundary of its territorial jurisdiction: (1) when there is duplication of names or other conditions which tend to confuse the traveling public or the delivery of mail, orders, or messages; (2) when it is found that a change may simplify marking or giving of directions to persons seeking to locate addresses; or (3) upon any other good and just reason that may appear to the commission. (C) On the name being changed, after reasonable opportunity for a public hearing, the planning commission shall issue its certificate designating the change, which must be recorded in the office of the register of deeds or clerk of court, and the name changed and certified is the legal name of the street or road. 20 21 22 (1) a. b. 1. 2. 3. 4. 5. (2) a. Sec. 38-9.3. - Dimensional requirements: General provisions and exceptions. In addition to the dimensional requirements listed below and district dimensional requirements, further dimensional requirements may be set forth in article 5 for those uses listed as conditional. The control free district shall be exempt from the provisions of this section except provisions listed under item (2), setbacks. Lot size and configuration. Public utilities and government. Public utilities and government uses shall not be subject to the minimum lot size requirements, but shall meet the setback requirements. Flag lots. Flag lots may be permitted under the following conditions: The maximum length of the pole of a flag lot shall be 300 feet. The minimum width of the pole of a flag lot shall be 22 feet, and the maximum width of the pole of a flag lot shall be 40 feet. The front setback shall be measured from where the flag portion of the flag lot meets the district minimum width requirements. The pole portion of a flag lot shall not be used to calculate width, or setbacks of the lot, or to provide off-street parking. There shall be no more than one flag lot per each four lots, per subdivision or development. Flag lot illustration: Setbacks. The required front, side, and rear yards for individual lots shall be measured inward toward the center of said lot from all points along the respective front, side, and rear property lines of the lot, or from the road right-of-way if applicable. Once the yard areas of a given lot have been established, the remaining area of the lot which is not included in any required front, side, or rear lot shall be known as the "buildable" area within which the approved structure(s) shall be placed. 2/25/25, 12:29 PM Oconee County, SC Code of Ordinances about:blank 1/3 23 b. c. d. e. f. g. h. i. Where a road right-of-way projects over a property line, the setback shall be measured from the road right-of-way line. Corner lots shall be considered to have two fronts and shall meet the front setback for the district. Front yard setbacks for double frontage lots shall be provided for both streets upon which the lot has frontage, and any accessory use(s) shall be prohibited from the required front yard setback of the street upon which the principal building fronts. For lots not meeting the required minimum lot width for the respective district at the front property line or road right-of-way, as applicable, the setback shall be measured such that the distance from the front property line or road right-of-way, as applicable, shall nonetheless be included in the measurement for the required setback. The buildable area shall not, however, include any area where the minimum lot width is not met. This provision is meant to apply to irregularly shaped lots, as generally determined by their existing lot width and configuration in relation to the district minimum lot width. This provision does not apply to flag lots. See section 38-9.3(1)(b) for flag lot provisions. Road design and encroachment criteria is governed by the standards in chapter 26, of the Oconee County Code of Ordinances, as amended. Any garage door shall be set back a minimum of 20 feet from the property line that it faces so that vehicles may be parked in the driveway without encroaching into the right- of-way. If the district setback is greater than 20 feet, then the more restrictive setback shall prevail. The side and rear setbacks in the CCD and HCD shall not apply to the shared property line of attached buildings. 2/25/25, 12:29 PM Oconee County, SC Code of Ordinances about:blank 2/3 24 j. The space in any required yard shall be open and unobstructed except for the ordinary projections of window sills, cornices, eaves, window air conditioning units, and other architectural features, provided that such features shall project no more than two feet into any required yard. Steps and heating and cooling units may project into a required yard a distance not to exceed five feet but no closer than five feet of a property line. Fences, freestanding walls, hedges, and septic lines may be located in any setback, so long as they remain on the property. (Ord. No. 2012-14, § 1, 5-15-2012; Ord. No. 2018-19, § 1(Att. A), 8-21-2018; Ord. No. 2024-23, §§ 1, 2(Exh. A), 10-15-2024) 2/25/25, 12:29 PM Oconee County, SC Code of Ordinances about:blank 3/3 25

Source: Oconee County website. First collected Nov 14, 2026.