Minutes
City of Sumter · Sumter County · Minutes
Open the original document More from City of Sumter
Text
Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.
ZONING BOARD OF APPEALS
Minutes of the Meeting
July 10, 2024
ATTENDANCE
A regular meeting of the Zoning Board of Appeals was held on
Wednesday, July 10, 2024, in the Fourth Floor City Chambers of
the Sumter Opera House, 21 N. Main Street. Six board members
–Mr. Leslie Alessandro, Mr. William Bailey, Mr. Frank Shuler ,
Mr. Jason Reddick, Mr. Steven Schumpert and Mr. Todd
Champion were present. Mr. Louis Tisdale, Mr. Claude Wheeler
and Mr. Clay Smith were absent.
Planning staff in attendance : Mr. Jeff Derwort , Ms. Helen
Roodman, Mr. Kyle Kelly and Ms. Kellie Chapman.
The meeting was called to order at 3: 14 p.m. by Mr. Leslie
Alessandro, Chairman.
MINUTES
Mr. Frank Shuler made a motion to approve t he minutes of the
June 12, 2024, meeting as written. The motion was seconded by
Mr. Jason Reddick and carried a unanimous vote.
NEW BUSINESS
Mr. Frank Shuler recused himself from BOA-24-24
BOA-24-24, 23 Haynsworth St. (City) was presented by Mr.
Jeff Derwort. The Board reviewed the request for a variance
from the accessory structure setback requirements and fence
placement requirements outlined in Article 4.g.2.b.4: (Residential
Accessory Structures) Setbacks and Article 4.f.8: Height, Fencing
Materials, and Proximity Regulations for Fences Allowed in Required
Yards of the City of Sumter Zoning & Development Standards
Ordinance (the “Ordinance”), and any additional variances as
may be required, in order to (1) establish a resi dential accessory
structure closer to a side property line than otherwise permitted
and (2) establish an 8 ft. tall solid fence closer to an existing
structure on an adjacent property than otherwise permitted. The
property is located 23 Haynsworth St., is zoned Residential-6 (R-
6), and is represented by TMS# 228-05-01-023.
Mr. Derwort stated the applicant is in the process of constructing
a residential storage building in the rear yard of the property.
Mr. Derwort added building permits were issued for the project
earlier this year based on a variance approval obtained in 2018
under Case# BOA-18-05 that provided 3.5 ft. of relief from side
2
accessory structure setback requirements and 3 ft. of relief from
rear accessory structure setback requirements.
Mr. Derwort mentioned the applicant is requesting additional
variance relief to reduce the side setback to +/- 1 ft. and the rear
setback to +/ - 1.5 ft. Per the applicant, the condition of the
existing concrete slab is not suitable to act as a building
foundation, and a pole barn style structure with supports located
outside the slab is being erected.
Mr. Derwort stated the applicant has completed an 8 ft. tall
wooden privacy fence along the western property line in the side
and front yards and desires to continue the fence in the rear yard
close to the western property boundary line. The applicant is
requesting a variance to allow for +/ - 2.5 ft. of separation
between the proposed fence and existing accessory structures on
the adjacent property. Base
d on the proposed height of the
fence, the Ordinance requires 8 ft. separation between the fence
and existing structures on the adjacent property.
Mr. Raymond Hodge was present to speak on behalf of the
request.
Mr. John Daly was present to speak against the request.
After a brief discussion, Mr. William Bailey made a motion to
approve this request subject to the following:
1. Accessory Structure – The condition of the existing slab is
not suitable to serve as the supporting foundation for an
accessory structure, a condition that arose after the original
variance approval (BOA-18-05). Based on this condition, the
applicant has elected to construc t a pole bare style structure
with support columns installed directly adjacent to the outer
limits of the concrete slab.
The rear yard of the property is influenced by the presence
of 3 mature canopy trees classified as ‘significant’ trees per
Article 9 of the Ordinance. In order to construct the
proposed building to meet required setback requirements,
impacts to the critic al root zones resulting in long term
impacts to these mature trees are anticipated for the structure
to comply with minimum accessory structure setback
requirements. This reasoning was cited in the original BOA-
18-05 approval that allowed for the 3.5 ft. reduction in the
minimum side setback and the 3 ft. reduction to the required
minimum rear setback. While single -family detached
dwellings are exempted from the tree preservation and tree
protection requirements outlined in Article 9 of the
Ordinance, pre serving these trees is consistent with the
overall intent and purpose of the Ordinance.
3
2. Accessory Structure – The utilization of an existing
concrete slab (the location of a previous accessory structure)
to protect mature trees in close proximity is considered to be
a condition that is not generally applicable to all property in
the immediate vicinity.
3. Accessory Structure – The Ordinance prevents the
applicant from constructing the accessory structure in the
manner desired due to required setback encroachments. The
applicant has provided information indicating that the
condition of the existing slab is not suitable to provide
foundational support for an accessory structure. Further,
construction in full compliance with the minimum 5 ft.
setback appliable to residential accessory structures of this
size could endanger the health of existing ‘significant’ canopy
trees.
4. Accessory Structure – The purpose of regulating setbacks
for residential and accessory structures is to ensure
compatibility, ensure minimum open space around a
structure, facilitate safe access, and avoid negatively
impacting surrounding properties. It is noted that this ar ea
is within the historic core of the City of Sumter where it is
common for both homes and their accessory structures to
have been constructed prior to 1999 and to conform to
current setback requirements. Further, the proposed
structure would not be readily visible from public right -of-
way and any potential impacts to adjacent property would be
limited to the rear yard areas of the property to the west and
the property to the north where boundary fences already exist
on the property lines.
The motion was seconded by Mr. Jason Reddick and carried by
a unanimous vote.
After a brief discussion, Mr. Jason Reddick made a motion to
approve this request subject to the following:
1. Fence Separation – This is an attempt to provide
additional screening from the adjacent property to the
west, where documented disputes with the adjacent
property owner have occurred in the recent past. An
existing accessory structure, with a window facing into
the applicant’s backyard, is located within less than 1 ft.
of the western property boundary. The applicant is
requesting a variance to install a privacy fence closer to
existing structures on the adjacent property than is
otherwise permitted to re solve their safety and privacy
concerns.
4
2. Fence Structure – The current need for additional
screening, security, and privacy (for the both the
applicants and the representatives of the adjacent
property) is considered to be a condition that is not
generally applicable to all property in the immediate
vicinity.
3. Fence Separation – The Ordinance prevents the
applicant from constructing the privacy fence in the
location desired. The fence separation standard does still
apply even if a structure on an adjacent property does not
conform to required setback requirements, which is the
case in this situation. If the closest residential accessory
structure on the adjacent property met the 5 ft. minimum
setback requirement, the proposed privacy fence would
have to be installed +/ -
3 ft. from the property line.
Based on the actual location of the neighboring buildings,
the proposed privacy fence would need to be placed +/-
8 ft. from the property line to maintain the required
separation outlined in Article 4.f.8.
4. Fence Separation – The purpose of requiring separation
between solid fences and existing accessory structures on
adjacent property is to ensure compatibility, to ensure
minimum open space around a structure, to facilitate safe
access, to avoid negatively impacting surrounding
properties, and to prevent damage to adjacent structures
in the event a fence was to fall. It is noted that there are
extenuating circumstances pertaining to the subject
property and the abutting property to the west.
Additionally, t he existing accessory structure on the
adjacent property appears to be approximately 1 ft. from
the property boundary line, thus requiring an 8 ft. tall
privacy fence to be significantly setback on the subject
property. Any potential impacts to adjacent property
would be limited to the rear yard of the property to the
west.
With the following condition of approval:
• The eave overhang and roof drip line for the
accessory structure shall not encroach over any
boundary line of the subject property.
The motion was seconded by Mr. Steven Schumpert and carried
by a unanimous vote.
BOA-24-25, 4672 Broad St. (County) was presented by Mr. Jeff
Derwort. The Board reviewed the request for a special exception
approval in accordance with Article 1.h.4.c: (Powers of the Zoning
Board of Appeals) Special Exceptions, Article 3.i.4: (GC District) Special
Exceptions, and Article 3, Exhibit 5: Permitted Uses in All Zoning
5
Districts of the Sumter County Zoning & Development Standards
Ordinance (the “Ordinance”) in order to establish a Hookah
Lounge (NAICS 7139) on the property. The property is located
at 4672 Broad St., is zoned General Commercial (GC), and is
represented by TMS# 155-08-02-003.
Mr. Derwort mentioned the Board of Zoning appeals approved
a variance for parking on May 8, 2024. After further research, it
was determined a Hookah Lounge (with no one -site
consumption of alcoholic beverages) falls under NAICS code
7139, Other Amusement and Recreation Industries which
requires Special Exception approval.
Ms. Sunny Wise was present to speak on behalf of the request.
After a brief discussion, Mr. Frank Shuler made a motion to
approve this request subject to the following:
1. The commercial multi -tenant building and associated site
improvements were constructed circa 1986, prior to the
adoption of the current Ordinance. The Board of Zoning
Appeals approved a variance for minimum parking area on
May 8, 2024.
2. The Board Street Corridor is characterized by strip
commercial development with residential development to the
rear. Like much of the commercial development on Broad
St., this location fronts on Broad St. with direct access to and
from Broad St., with no direct vehicular or pedestrian access
to the rear of the property. There are significant areas of
vegetation to the rear of the property acting as buffer
between the established residential uses and this location.
The proposed use will be in substantial h armony based on
the existing site characteristics and the proposed use location.
3. Based on the existing site configuration and access, including
existing buffering, there is no indication the proposed use will
discourage or negate the use of surrounding property for
use(s) permitted by right.
Subject to the following condition of approval:
• No alcohol shall be served or consumed on the
premise of this business.
The motion was seconded by Mr. Steven Schumpert and carried
by a unanimous vote.
BOA-24-26, 190 Corbett St. (County) was presented by Mr.
Kyle Kelly. The Board reviewed the request for a variance from
the minimum lot size and public road frontage requirements
outlined in Article 3.n.5.a: (AC District Minimum Lot Requirements)
6
and in Article 8.e.13.a: Lots and Article 8.e.13.c: Lots of the Sumter
County Zoning & Development Ordinance (the “Ordinance”) in order
a to subdivide a tract of land that will result 2 new lots being
established below minimum lot area requirements, 3 new lots
being established with no or less than the required amount of
public road frontage. The Ordinance requires a 1-acre minimum
lot size for new lots in the AC zoning district and requires at least
60 ft. of frontage on a public road (unless otherwise exe mpted).
The property is located at 190/220 Corbett St., is zoned
Agricultural Conservation (AC), and is represented by TMS#
308-00-01-001.
Mr. K elly stated the applicant is requesting variances to the
development standards in order to establish 3 new lots that do
not meet minimum public road frontage requirements. 2 of the
proposed new lots also would not meet the minimum AC district
lot size requirement. The parent parcel is a +/ - 110.69-acre
agricultural tract that contains 2 manufactured homes.
Mr. K elly added the tract contains a grandfathered
nonconforming use (2 dwellings). The applicant is attempting to
subdivide the tract into 4 lots as part of settling an estate. 3 of the
4 lots require variance approval.
Mr. Kelly mentioned dating to at least 1966, Corbett Street was a
dirt road, with most of the subdivided properties described by
deeds (without plats). The street was paved prior to 2001, though
no formal easement or ROW data can be found showing
conveyance to Sumter County.
Ms. Mary Lynda Tiller Dutcher was present to speak on behalf
of the request.
After a brief discussion, Mr. Frank Shuler made a motion to
approve this request subject to the following:
1. The subject property is +/- 110.69-acres in size, with
approximately 3,700 linear feet of frontage on Sumter Rd.
The lot contains a non -conforming use not subject to
discontinuance, as there are two (2) manufactured homes on
the tract. The proposed division would resolve the potential
non-conforming use issue.
While there are numerous uniquely shaped parcels of record
in proximity to this site, none contain the existing
development pattern and roadway development conditions
of the subject parcel. While there exists sufficient property
to complete ordinance-compliant division of the land, such
a division would create new property lines that could
complicate the future use of the parent tract for agricultural
use on a contiguous field.
7
2. Lots and tracts in this area of Sumter County are generally a
combination of large agricultural and undeveloped tracts and
small residential lots. The property is directly adjacent to the
Town of Mayesville, which, as a municipality, maintains its
own zon ing regulations and development standards that
allow for smaller lots.
The existing development pattern on Corbett St., which has
contained single family residences on the western side of the
private road and open agricultural fields to the east, has been
in place since the mid-1960s. The Town of Mayesville water
and sewer u
tilities extend to serve the area, making
development of smaller lots physically feasible, as septic
systems are not required.
All properties in Sumter County are required to abide by
Article 8.e.13. standards, save for those defined as exempt
subdivisions under Article 10, which is limited to agricultural
restricted uses and family exempt subdivisions.
3. The application of the ordinance to the particular property
restricts the ability of the applicant to divide the tract as
desired in order to convey Parcels A, B, and C to separate
individuals as part of settlement of a deceased parent’s estate.
While the individuals to receive the property are unrelated to
the current owners, they have lived on the property for a
significant period of time, and were farm employees.
4. Article 8.e.13. requires that newly subdivided lots be
established with public road frontage in order to minimize
the presence of “landlocked” lots, meaning tracts of land that
cannot be reached but by crossing another property owner’s
land. While easements are employed as a means to establish
legal access to property, their application and enforceability
is left to individual property owners, leaving situations in
which property becomes difficult to access for its owners.
Article 8.e.13. ensures that lots are created with the necessary
width to allow access without requiring easements across
property owned by other individuals. However, in this
particular instance, it is not anticipated that granting the
requested variance will be of substantial detrimen t to the
adjacent property or the public good nor it is anticipated to
harm the character of the district.
The motion was seconded by Mr. Jason Reddick and carried by
a unanimous vote.
BOA-24-27, 850 Flagg St. (County) was presented by Mr. Jeff
Derwort. The Board reviewed the request for a variance from
the accessory structure development requirements outlined in
8
Article 4.g.2.a.1: (Residential Accessory Structures) Conditions &
Exceptions, Article 4.g.2.b.6: (Residential Accessory Structure)
Maximum Size, and Article 4, Exhibit 8A: Maximum Square
Footage of Residential Accessory Structures Based on Gross
Acreage o f the Sumter County Development Standards
Ordinance (the ”Ordinance”) in order to establish a residential
accessory structure on a property in the AC zoning district that
is less than 5 acres in size with no principal residential dwelling
and to establish a residential accessory structure over the
maximum size limit based on the gross acreage of the property.
The Ordinance only allows for residential accessory structures to
be established on property with no principal residential structure
where the property is zoned AC and where the property is 5 acres
or larger in size. The property is +/ -
2.49 acres in size, with
maximum residential accessory structure area limited to 1,850 sq
ft. The property is located at 850 Flagg St., is zoned Agricultural
Conservation (AC), and is represented TMS# 230-00-01-007.
Mr. Derwort stated the maximum size accessory structure for a
2.49-acre lot is 1850 sq. ft. Currently the owner is proposing to
construct a 35’X65’ (2,275 sq. ft.) to include a porch (dimensions
on the size of the porch and if it will be under roof are not
available at time report draft).
The property is in the Agricultural Conservation (AC) zoning
district, is 2.49- acres in size, and does not have principal
residential dwelling located on it. As such, a variance is required
to establish a residential accessory structure of any size on the
property. In the AC zoning district, if a property is 5 -acres in
size or more, a residential accessory structure can be established
on a property in absence of a principal residential dwelling.
The applicant intends to place the structure along the southern
side of the property in compliance with applicable principal
residential structure setbacks requirements.
The applicant received a setback variance for an unrelated
agriculture building on the same property on July 12, 2023. As
of July 2, 2024, the agriculture building is under construction.
Mr. Justin Hurst was present to speak on behalf of the request.
After a brief discussion, Mr. Frank Shuler made a motion to
approve the request subject to the following:
Accessory Structure Placement on 2.49- acre With No
Primary Dwelling
1. The subject property comprises a +/- 2.49-acre parcel. The
applicant owns and resides on a +/- 1.95-acre lot located
directly across Flagg St. from the subject property. Flagg St.
9
right-of-way divides these properties but includes an unpaved
dead-end turnaround in front of the subject property.
More than half of the subject property is within Zone A
Special Flood Hazard Area (SFHA) as shown on FEMA
FIRM Panel 45085C0303E, Effective Date: 10-27-22. While
residential development could occur on this lot in
compliance with County Zoning and County Flood Damage
Prevention Ordinance requirements, it is not preferred as the
property is considered to be at risk for flooding. It is noted
that the boundary of the floodplain line is the limits of the
flood study, not necessarily the limits of the actual 1% annual
risk for flooding.
While there are numerous uniquely shaped parcels of record
in proximity to this site, none contain the existing
development pattern and roadway development conditions
of the subject parcel. While there exists sufficient property
to complete ordinance-compliant division of the land, such
a division would create new property lines that could
complicate the future use of the parent tract for agricultural
use on a contiguous field.
2. Special Flood Hazard Area (SFHA) boundaries were recently
expanded in this area with the latest 2022 FEMA flood map
update. This particular lot within the Jefferson Park
subdivision is the most impacted and is also the only
undeveloped lot on the south si de of Flagg St. These
conditions further limit the development potential of this lot.
3. The Ordinance requirements prevent the applicant from
constructing an residential accessory structure on the
property in absence of a principal residential dwelling, as the
property not meet the criteria for exemption in the AC
district since it is not 5- acres or more in size. The property
is not ideal for the development of a residential dwelling due
to flood risk.
4. The authorization of a variance to allow for the construction
of residential accessory structure in absence of principal
residential dwelling is not likely to result in substantial
detriment to adjacent property or the public good, nor is it
likely to harm the character of the district. The property was
created prior to the adoption of effect flood plain maps.
Based on the risk identified by the effective floodplain maps,
the property is not ideal for the development of a residential
dwellings.
The motion was seconded by Mr. Steven Schumpert and carried
by a unanimous vote.
10
After a brief discussion, Mr. William Bailey made a motion to
approve the request subject to the following:
Allowance for Additional Accessory Structure Area:
1. The property is primarily located in a SFHA, is not
suitable for septic, and is not suitable for residential
development. No dwelling is proposed or desired, so an
increase in size allowed is off -set by the absence of a
dwelling on the property.
2. Special Flood Hazard Area (SFHA) boundaries were
recently expanded in this area with the latest 2022 FEMA
flood map update. This particular lot within the Jefferson
Park subdivision is the most impacted and is also the only
undeveloped lot on the south side of Flagg St. These
conditions further limit the development potential of this
lot. The property is not suitable for septic, and is not
suitable for residential development. No dwelling is
proposed or desired, so an increase in size allowed is off-
set by the absence of a dwelling on the property.
3. Residential development on the property is not feasible.
Thus, overall building square footage impacts are
comparable to an actual primary residential structure in
addition to an accessory structure at the maximum area
permitted.
4. The authorization of a variance to allow for additional
accessory structure square footage is not likely to result
in substantial detriment to adjacent property or the public
good, nor is it likely to harm the character of the district.
The property is impacted by conditions that make the
development of a primary residential dwelling unfeasible.
As such, overall building square footage impacts are
comparable to an actual primary residential structure in
addition to an accessory structure at the maximum area
permitted.
The motion was seconded by Mr. Jason Reddick and carried by
a unanimous vote.
OTHER BUSINESS
Ms. Helen Roodman informed the Board that a public meeting
for the UDO will be held on July 24, 2024, at the Meeting House.
Dates for Continuing Education will be announced soon.
There being no further business, Mr. Frank Shuler made a
motion to adjourn the meeting at 4:38 p.m. The motion was
seconded by Mr. Jason Reddick and carried by a unanimous vote.
11
The next regularly scheduled meeting is scheduled for August 14,
2024.
Respectfully submitted,
Kellie K. Chapman
Kellie K. Chapman, Board Secretary
Source: City of Sumter website. First collected Nov 14, 2026.