Historic Preservation Design Review June 25, 2020 HP-20-08, 10 S. Main St. (City) I. THE REQUEST Applicant: R. Scott Bell Status of the Applicant: Project Architect Request: Design Review approval for rear elevation renovations. Location: 10 S. Main St. Present Use/Zoning: Commercial / CBD Tax Map Reference: 228-13-07-015 Adjacent Property Land Use and Zoning: North – Sumter Original Brewery / CBD South – Vacant Building / CBD East – S. Main St. / CBD West – Pedestrian Alley & Liberty Center / CBD II. BACKGROUND 10 S. Main St., (front elevation shown in the photograph to the right ), was most recently used by Standard Music and as storage space. Long term plans for the building include use of the rear of the facility as storage sp ace for p roduct from the adjacent brewery . The storefront and second floor uses are undetermined at this time. The A pplicant is requesting design review approval to make alterations to the rear (alley - facing) elevation of the building in order to provide improved a ccess to the space for large items, and to make cosmetic changes inclu ding new paint and removal of abandoned u tility conduits. 2 Historic Context Based upon the Sumter County Assessor’s Record, the building was constructed in 1910, however a s tructure existed on this site as early as 1889 based upon Sanborn maps. The earliest photo of the building, shown to the r ight was from the 1900s. Based upon archival photos, by 1959, the upper façade had been altered to include covering of the six (6) se cond story windows and brickwork. By 1985 when the first Downtown historic resources survey was undertaken, all historic character had been removed or covered over and the structure was deemed to not be contributing to the National Register Historic District. In t he early 1900s, prior to façade alterations, the building was a good architectural example of the Main Street Commercial Form. This architectural style was popular from 1875 to around 1940. Main Street Commercial Buildings feature ground level stor efronts with large display windows to showcase goods to consumers. Upper stories usually functioned as living space for th e shop owner or as storage. The building plan is generally rectangular with a symmetrical façade. Roofs are typically fla t with a par apet. Ent rances are commonly glazed doors with transoms flanked by large storefront windows to display goods surmounted by transoms. Windows on upper floors are typically double -hung sash windows. Const ruction materials are commonly brick, wood, stucco, an d cast me tal. Decorative wood, brick or metal cornices, patterned or corbelled brickwork and sign bands are not uncommon, In 2018, following design review approval, the site’s previous owner conducted some facade restorations which included removal of an awning and demolition of portions of the previous facade that were not considered historic. 3 Site Photos: Rear building (alley) elevation North side door (proposed for replacement with 8x10 ft coil-up door and new 3x7 ft metal door) View of pedestrian and service alley from south South side door (proposed for replacement with new 3x7 ft metal door. 4 Scope of Work: It is the A pplicant’s intent to complete r ear elevation renovations to the building , which faces an existing alley. Renovations include adjustments to doors, removal of abandoned utility conduit, and repainting. Based upon the submitted architectural elevation/rendering, the following is proposed: 1) Install new 8x10’ coil-up door 2) Replace existing north side door with new painted 3x7’ hollow metal door and shift door location to accommodate new coil-up door; 3) Replace existing south side door with new painted 3x7’ hollow metal door; 4) Remove existing abandoned sprinkler lines; 5) Remove existing abandoned downspout; 6) Remove existing exposed electrical conduit; 7) Repaint existing windows, trim, bars, and sills; 8) Paint brick walls; Below, a building elevation shows the scope of proposed renovations. 5 The proposed colors are shown below. Renwick Beige will be the wall color. Fairfax Brown will be the door color, and Classical White will be the window, trim, bar, and sill color. Design review approval is required prior to the proposed work. The Design Review Guidelines Manual states: 4.3 Exterior Walls: Masonry Exterior masonry walls exist in both the commercial and residential historic district. Masonry materials include brick, stone, concrete, stucco, and terraco tta. Brick i s the most common m asonry material used in Sumter and is used primarily for exterior walls, foundations, and chimneys. Some exterior masonry walls are solid brick, while others are brick veneer, consisting of a single brick course over a wood frame structu ral system. In both cases, the brick exterior wall surface, and their associated bond patterns and textures, define the appearance and character of the building. Masonry elements can also be used to create decorative details and textures, such as corbelled brick patterns and inlays or bel t courses. The color and texture of masonry is an important defining feature, as is the mortar that bonds the masonry units. Mortar for mo st historic buildings is composed of a mixture of lime and sand, which a llows for ex pansion and co ntraction of the mortar joint in hot and cold weather. In most cases, the use of modern Portland cement is not appropriate for historic buildings, as it is stronger than traditional historic mortars and does not allow for joint expansion or co ntraction. It is common for houses and commercial buildings in the historic districts to feature a flush or concave mortar joints. A. Preserve Original Masonry and its Visual Qualities.  Retain masonry features that are important in defining the overall character of the building.  Do not remove or obscure masonry elements.  Do not paint unpainted masonry. Exceptions to this include masonry walls that have a patchwork appearance from extensive replacement or rebuilding. 6 Staff Analysis: The proposed project meets the above s tandards. The brickwork on the rear elevation of the site has been pr eviously painted, and removal of aban doned non-historic utility elements, including abandoned electrical and sprinkler conduit s and downspouts will result in better visibility of the masonry itself. 4.8 Doors Doors provide attractive, welcoming entrances to interior spaces. Like windows, they reflect the architectural style of a building and are important elements of architectural character. C. Add New Door Openings in a Man ner that Minimizes Impact on Historic Features and Subtly Distinguishes Them from Historic Doors.  Select an inconspicuous location for new door openings, such as the rear or side elevations not visible from the street.  Use clear glass for doors on the pri mary and read ily visible seconda ry facades. Tinted glass may only be used on rear or side elevations not visible from the street  Decorative or stained glass is only appropriate if there is evidence that this feature existed historically  Modern wood, fiberglass, or steel doors may be appropriate on rear or side elevations that are not visible from the street. Staff Analysis: The proposed adjustments to the door configuration meet the ab ove standard. The proposed work is in the rear alle y of the building, an inconspicuous area not immediately visible from the street . The alley is, by nature, intended to support non- public building access and use for bringing deliveries into the building. 4.11 Paint B. Select a Compatible Color Scheme.  Choose col ors that a re appropriate to the architectural style and complement the building and i ts surroundings. Overly bright and obtrusive colors are not appropriate.  Consider an original color scheme based on paint analysis or research. C. Use Paint Color to Accentuate Exterior Details.  Use muted or dark colors for the walls of a building.  Use lighter colors to highlight trim and architectural ornamentation.  Paint window sash and frames a contrasting color than the walls to provide contrast and depth to window openings. 7  Limit the paint scheme to three or four colors: one roof color, one wall color, on trim color, and one accent color. Staff Analysis: The proposed color scheme meets the above standard s. The colors selected are in keeping with the o verall architectural style of the area and the paint select ed is limited to one (1) wall color, one (1) trim color, and one (1) door color. III. STAFF RECOMMENDATION Staff recommends approval of this request. The overall proposal is compatible with established guidelines and is based upon photographic record from the structure’s period of significance. IV. DRAFT MOTION 1.) I move that the Sumter Historic Preservation Design Review Committee approve HP-20-08 in accordance with the materials, photographs, and co nstruction details submitted an d referenced in the Sta ff Report based on compliance with Design Review Guidelines. 2.) I move that the Sumter Historic Preservation Design Review Committee deny HP - 20-08. 3.) I move that the Sumter Historic Preservation Design Rev iew Committee enter a n alternative motion. V. HISTORIC PRESERVATION – MARCH 26, 2020 The scheduled March 26, 2020 Historic Preserva tion Design Review Committee meeting was postponed by order of City Counc il, in the keeping with Center f or Disease Control (CDC) guidelines related to the COVID-19 virus. VI. HISTORIC PRESERVATION – JUNE 25, 2020

Source: City of Sumter website. First collected Nov 14, 2026.