RecordWell Data

Planning Commission Regular Meeting — Agenda Packet

City of Beaufort · Beaufort County · Planning Commission · meeting of Nov 16, 2026 · Agenda packets

Open the original document More from City of Beaufort

Text

Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.

MEETING AGENDA The City of Beaufort PLANNING COMMISSION 1911 Boundary Street, Beaufort, SC 29902 Phone: 843-525-7011 ~ Fax: 843-986-5606 Monday, November 16, 2026, 5:00 P.M. City Hall, Council Chambers, 2nd Floor – 1911 Boundary Street, Beaufort, SC Please click the link below to join the webinar: https://us02web.zoom.us/j/82720900249?pwd=5k8z3FJCDgh1wtdeYwO59QqYXAd7nO.1 Password: 166490 Meeting ID: 827 2090 0249 Call in Phone #: 1+929-205-6099 STATEMENT OF MEDIA NOTIFICATION: "In accordance with South Carolina Code of Laws, 1976, Section 30-4-80(d), as amended, all local media were duly notified of the time, date, place and agenda of this meeting." Please note, this meeting will be broadcast via zoom and live-streamed on YouTube. You can view the meeting at the City's page; City of Beaufort Government I. Call to Order II. Pledge of Allegiance III. Review of Commission Meeting Minutes: A. October 19, 2026 Regular Meeting Minutes. IV. Questions Relating to Military Operations V. Applications: A. Rezoning. The Applicant, BTB Pursuit, LLC, is requesting approval of a rezoning of the property located at 1102 Craven Street from T4-N (T4-Neighborhood) to T5-DC (T5- Downtown Core) District. The property is further identified as R120 004 000 1037 0000. B. Rezoning. The Applicant, BTB Pursuit, LLC, is requesting approval of a rezoning of the property located at 1103 Bay Street from T4-N (T4-Neighborhood to T5-DC (T5-Downtown Core) District. The property is further identified as R120 004 000 0845 0000. PC Agenda November 16, 2026 Page 2 C. Preliminary Plat and Site Plan Request. Tim Brutcher, Carolina Engineer, on behalf of Wheeler & Wheeler, is requesting Site Plan and Preliminary Plat approval for a new townhome community located at 69 Meridian Road. The property is further identified as R123-015-000- 156A-0000 and R123 015 000 0156 0000. VI. Adjournment Note: If you have special needs due to a physical challenge, please call Julie Bachety at (843) 525-7011. 1 Planning Commission Regular Meeting Minutes – October 19, 2026 CALL TO ORDER 2:10 A regular meeting of the Planning Commission was called to order by Chairman Mike Tomy and was held in-person in the Council Chambers on October 19, 2026 at 5:00 PM. The meeting was broadcasted via zoom and live-streamed on YouTube. You can view this meeting at the City’s page; City Beaufort Government. ATTENDEES Members in attendance: Mike Tomy, Chairman, Bill Bardenwerper, Vice-Chairman, Libby Anderson, Secretary, Clinton Hallman, Michael Holle, Kim McFann, and Benjie Morillo. Staff in attendance: Curt Freese, Community Development Department Director, Christopher Klement, Planner III, and Nick Navia, Planner II. REVIEW OF MINUTES 2:58 A. September 21, 2026 Regular Meeting Minutes Mr. Bardenwerper noted on page 5, under Miscellaneous Discussion, the third line in the motion doesn’t make sense. He suggested rephrasing it to “The letter expresses the City Planning Commission’s desire for consultation between the two Planning Commissions with respect to Seabrook Farms” and then crossing out the rest of it. Ms. Anderson noted on page 5, in the bottom paragraph, to delete the sentence that says, “There was a published document in the Beaufort Gazette from Port Royal that they do have representatives at the State”. Ms. Anderson also noted on page 5, in the second sentence from the bottom sentence, add the word “by” after the word “occupied”. Motion: Mr. Bardenwerper made a motion to accept the minutes with the noted changes. Mr. Hallman seconded the motion. The motion passed unanimously. B. October 5, 2026 Worksession Minutes Mr. Bardenwerper stated the minutes need to reflect that he attended the meeting remotely via Zoom. Ms. Anderson noted on Page 2 in the fifth sentence to delete the words “as a portion”. 2 Ms. McFann referred to the handout that Paul Trask gave to the Planning Commission to be part of the October 5, 2026 minutes. Motion: Mr. Hallman made a motion to approve the minutes with the noted changes. Ms. Anderson seconded the motion. The motion passed unanimously. QUESTIONS RELATING TO MILITARY OPERATIONS 7:34 None. APPLICATION 10:28 A. The Grove at Broad River. The Applicant, Eric Walsnovich with Woods and Partners, is requesting Site Plan Approval for a multi-family community located at 14 FC Carter Drive. The property is further identified as R120 029 000 0045 0000. Christopher Klement presented his staff report. Public Comment: Joyce Ham, who resides off Glaze Drive, is concerned with the proposed entrance to the apartments being at Glaze Drive as there wouldn’t be enough room. Ms. Ham referred to her church, Burton New Church of Christ, as well as the New Hope Christian Church, both being located at the traffic light with Broad River Blvd. She is generally concerned with how the new apartments are going to impact the general traffic in that area. Public comment was closed. Motion: Mr. Bardenwerper made a motion to table the project for sixty days so the applicant can address issues that have been raised during the meeting. Ms. McFann suggested amending the motion to say, “we continue it for 60 days to allow everybody to address the architectural issues and request that Planning Commission gets a unified list of any outstanding issues for the continued hearing, including the stated update/memo to the traffic impact study, and specifically notice from BJWSA regarding sewer lift station improvements that will have to be completed prior to construction of the project. Moreover, to hear from staff if a six-foot stoop and six-foot deep porches with the Code.” Staff Recommends Preliminary Site Plan Approval with the following recommendations: o Sidewalks are not provided along all streets, including Broad River Blvd as required in T- 5 UC Section 7.1.3. o Per Section 4.4.B of the Beaufort Code, “porches shall have a minimum depth of 8 feet and a minimum width of 25% of the primary façade.” The porches are measured at 6’ – 0,” and need to be extended to meet code compliance. Applicant shall also demonstrate compliance with the 25% width requirement. o Applicant to provide diagrams demonstrating that the primary street-fronting elevation meets fenestration percentage requirements per Section 4.6.3.C.1. 3 o A regional lift station is required to be under construction before Final Approval and therefore Vesting is granted. The final decision by the PC is good for 24 months with a one 12 month extension, but no vested right, (and thus no development or building permits will be issued) is triggered until confirmation from BJWSA that a regional lift station is under construction. o General Architecture Comments from the Meadors Comments listed as part of the packet, be studied and revisions be brought back for Final Approval. o TIA updates, including all comments found on pages 7 and 8 of this Staff Report, will be considered and resubmitted for consideration before Final Approval. o At Final approval, the primary entrance onto Parris Island Gateway (roundabout etc), must be constructed before CO’s are issued. Mr. Hallman seconded the motion. The motion passed unanimously. Mr. Freese clarified sixty days from tonight will be December 21. B. Sketch Plan – Marsh Pointe Apartments Redevelopment Request. The Applicant, 3:07:06 Beaufort Housing Authority, is requesting Sketch Plan Review for a Major Subdivision for multi-family apartments located at 1716 & 1730 Greenlawn Drive. The property is further identified as R120 001 000 005F 0000. Curt Freese presented his staff report. Public Comment: Will Achurch, 55 Petigru Drive, stated he is the City appointed Commissioner for the Housing Authority. The applicant has done a great job with the project and has addressed all the concerns the Housing Authority had. Ethan James, 2698 Hanover Lane, stated his is a long time Beaufortonian and serves as the Chairman of the Beaufort Housing Authority. He said the applicant has been very receptive to listening to the Board of Commissioners and what we’d like to see out of this project. Mr. James sated we cannot afford to lose any units with the affordability crisis in Beaufort. Public comment was closed. Mr. Freese stated that the purpose of tonight’s meeting is to give the applicant some clarity and certainty moving forward. Mr. Freese suggested giving the applicant some recommendations. Several members of the PC suggested following changes to the applicant: 1. Installation of a walkway along the perimeter of the property is a high priority. 2. Building C currently does not have any appropriate frontage as it only fronts a parking lot. It should either face a public space or a neighborhood street with an appropriate sidewalk going along it. 3. Specific landscaping and stormwater plans would still need to be presented. 4. Trash dumpster relocation would be favored, if possible. 5. General concerns with too little parking as well as the pedestrian accessibility between parking spaces and building entrances 4 Staff Recommendation: Staff recommends Sketch Plan approval as per the findings of Section 7.5.3 with the following conditions/recommendations as this goes to a Site Plan. 1. The PC provide direction on whether the applicant should continue with the current layout with head in parking and essentially Greenlawn ending at the entrance, recommended by the Housing Authority; or the Staff recommendation to continue Greenlawn with street parking and parking to the southwest. Staff believes both proposals have merit, and the overarching goal is to provide good affordable housing to the community. 2. The applicant must provide an exhibit of street parking within 300 feet of the site whether these spaces can be allowed for inclusion with the minimum parking requirements. 3. The applicant shall restudy the open space provided, removing the open space designation in the middle of the parking lot, and considering other areas on the site for open space inclusion. 4. The applicant shall either choose to retain and prune some of the overarching limbs of the existing specimen and/or landmark trees instead of removal, specifically two of the Live Oaks to the east of Building A as well as the 32” Laurel Oak at the entrance, and the landmark tree to the South of Building C, or provide an arborist report stating of why these trees cannot be saved. MISCELLANEOUS DISCUSSION 4:19:55 Mr. Freese talked about setting up times for the stakeholders meetings. It was agreed to schedule the meetings on Wednesdays from 2:00 – 4:00 pm with the exception of November 11 which is Veterans Day. . Mr. Freese will send out a list of the dates to the PC. ADJOURNMENT 4:26:25 Ms. McFann made a motion to adjourn, seconded by Mr. Morillo. The meeting ended at 9:26 pm. STAFF REPORT: PLANNING COMMISSION (PC) – REZONING 1103 Bay Street and 1102 Craven Street DATE: 11/16/26 1 GENERAL INFORMATION Applicant: BTB Pursuit LLC, agent for Bay Street I, LLC and Lesesne Property Holdings LLC Site Address / Tax PIN: 1103 Bay Street; R120 004 000 0845 0000; 1102 Craven Street; R120 004 000 0845 0000 Applicant's Request: Applicant is requesting approval for 1556 Salem Road, property of the former Beaufort Gazette newspaper, to be rezoned T5-DC for a proposed 9 unit inn with a restaurant. Current Zoning: T4-N both lots Current Land Use: 1103 Bay Street (Anchorage) 1102 Craven Vacant Flood Zone/Base Flood: Flood Zone: X, Elevations: 9-12 feet (Base-Flood Elevation: > 13 ft.) Existing Landmark/Specimen Trees: No trees are affected by this request. ZONING DISTRICT INFORMATION T4-N Neighborhood Minimum Lot Width: None Required Frontage Build Out 60% min; 85% max Minimum Lot Size: None Required Max Impervious Lot Coverage: 70% Lot Coverage Front Setback 0’ min, 15’ max Side Setback Corner/Alley: 10’ max Interior: 5 ft min Attached: 0’ Rear Setback 10 ft min; 0 ft from Alley Building Height: 2 stories min; 4 stories max SURROUNDING ZONING, LAND USE AND REQUIRED BUFFERS Adjacent Zoning Adjacent Land Uses Required Buffer type(s) - see Sec. 5.4.1; 5.4.2; 5.4.3) North: T4-HN Historic Homes N/A South: River Beaufort River N/A East: T-5 DC Hotel, Commercial N/A West: T4-N Townhouses, Historic Homes, Office N/A 2 BACKGROUND: The applicant is requesting Rezoning approval from T-4 N to T5-DC pursuant to Code Section 9.16 for the current Anchorage lot at 1103 Bay Street, and the adjoining vacant lot at 1102 Craven Street. The properties are both currently zoned T4-N. While the properties are owned by different entities, the proposal is to rezone both lots, then consolidate the lots under one owner, and build a ~6,700 mixed use building with a 9 room inn, and a restaurant on the current Craven Street lot. T-4 N Legal Non-Conforming The 1103 Bay Street lot, the Anchorage which operates a 13 unit inn with a public restaurant, is currently legal non- conforming in the T-4 N district. The uses non-conforming include the Inn, in the table of uses Section 3.2, Inns are only allowed as a conditional use in T-4N, with the condition found in Section 3.6.2 C 3: Inn/Hotel/Motel: a. Specific to T4-N: i. Inns up to 10 rooms are permitted. With 13 guest rooms, the Inn is considered non-conforming and is prohibited from expanding. T4-N Retail Overlay: T-4 N allows retail and restaurants only in the retail overlay. Both of the properties part of this application are out of the T-4 retail overlay. This means the current restaurant would be legal non-conforming, and a new restaurant would be prohibited on the 1102 Craven Street lot T5-DC Zoning: The T-5 DC district allows retail, office, and multi-family uses. It prohibits industrial and vehicle/boat type uses, and single family homes are only allowed if they are existing. The purpose of the district (Section 2.3.2) is found below: The T5-Downtown Core district consists of higher density, mixed- use buildings that accommodate retail, rowhomes, offices, and apartments. A tight network of streets, including those in Beaufort's historic commercial downtown, allows this district to be a highly walkable area. Buildings are set very close to the street in order to define the public realm and allow for visible activity along the streetscape. 3 Comparison of permitted uses Use Category T4_N T-5 DC Single-family dwelling Permitted Existing buildings only 2–3 unit dwelling Permitted Permitted Rowhomes Conditional Permitted Apartments (4+ units) Conditional Permitted Group living (≤8 residents) Permitted Permitted Group living (>8 residents) Special Exception Special Exception College/University Conditional Permitted Retail & Restaurants Conditional Conditional Office Permitted Permitted Hotel/Inn/Motel Conditional Permitted Indoor entertainment Conditional Permitted Outdoor entertainment Conditional Permitted Vehicle sales/rental Artisan subdistrict only Prohibited Vehicle service/repair Conditional Prohibited Surface commercial parking Conditional Conditional Structured parking Retail frontage only Permitted Light industrial services Artisan subdistrict only Prohibited Manufacturing/production Artisan subdistrict only Prohibited Major infrastructure/utilities Artisan subdistrict only Prohibited T5- DC Lot Standards The lot standards allow for dense downtown development. As such, a lot can be completely covered by impervious surface with no setbacks, and up to 5 stories in height. See the Table below for the T-5 DC lot standards. 4 Conceptual Site Plan A conceptual Site Plan has been included as part of this packet. The site plan will be heard by the HDRB on November 18, as the property is within the Historic District. Therefore, all future site plans will be approved by the HDRB. However, the Planning Commission is allowed to require a conceptual site plan with a rezoning as per Section 9.16.3 B 3: At the discretion of the Planning Commission, the submittal may include the requirements of a Sketch Plan submittal as per Section 7.5.3, or a conceptual Site Plan (to include building elevations and any applicable Sketch Plan requirements as per Section 7.5.3) to be submitted with the map amendment request so that the impacts of development on the community are properly considered. The applicant has attended two HTRC meetings on the Site Plans (with architecture), and has made revisions based on comments from the HTRC committee. Again, the Site Plan will be approved by the HDRB, but the PC can require the conceptual plan with the rezoning. Parking: Neither property has on-site parking or is proposing it. There are a number of parking exceptions which can be utilized, from counting street parking within 300’ to shared parking that the applicant has discussed with Staff in the TRC meetings. In addition, T-5 DC allows a full parking exception for all non-residential uses. The exemption does not apply to inns but would apply to the restaurant should the rezoning be approved. T5-DC Downtown Minimum Lot Width: None Required Frontage Build Out 60% Minimum Minimum Lot Size: None Required Max Impervious Lot Coverage: 100% Lot Coverage Front Setback 0’ min, 15’ max Side Setback Corner/Alley: 10’ max Interior: 0 ft min Attached: 0’ Rear Setback 5 ft min; 0 ft from Alley Building Height: 2 stories min; 5 stories max; 3.5 stories max fronting Historic District 5 5.6.5 - PARKING EXCEPTIONS A .In the T5-DC District, all non-residential uses, except for motels/hotels/extended stay guest accommodations, shall be exempt from the off-street parking requirements of this section. Where such uses elect to provide off-street parking, it shall meet the design requirements of this section. FUTURE LAND USE: The area is categorized as General Urban by the Comprehensive Plan, and the Comprehensive Plan depicts both lots as General Urban in character. 9.16.3 C Finding of Fact Rationale Present (yes/no) Staff Analysis of Rationale a. Consistency (or lack thereof) with the Comprehensive Plan and Civic Master Plan Yes  The General Urban District supports the T-5 DC zoning. b. Compatibility with the present zoning, with conforming uses of nearby property, and with the character of the neighborhood Yes  The T-5 DC District is consistent and compatible with the adjoining properties to the East and West, and a logical extension of the downtown.  Rezoning to the T-5 DC district would correct the legal non-conforming status of the Anchorage. c. Suitability of the property that would be affected by the amendment Yes  The property can accommodate the conceptual site plan. 6 d. Compatibility with the natural features of — and any archaeological or cultural resources on — the property Yes  The Administrator can require an archaeological survey. e. Marketability of the property that would be affected by the amendment; and Yes  Moving the restaurant (which poses a fire risk) from the historic building, and adding more rooms, allows the owners to sell the property to a new owner who would then have the resources to maintain the historic property. f. The availability of roads, sewer, water, and stormwater facilities generally suitable and adequate for the affected property. Yes  Infill development in the downtown places the least amount of strain on the City’s infrastructure which it has spent the last few years upgrading.  Parking: if zoned T-5 DC, parking for the restaurant would be exempt, and on-street parking and marina parking exists within close proximity for the inn. FINDINGS AND RECOMMENDATIONS Staff recommends approval to the City Council, and meets the findings of Section 9.16.3 C, finding there is a. Consistency with the Comprehensive Plan and Civic Master Plan b. There is compatibility with the present zoning, with conforming uses of nearby property, and with the character of the neighborhood c. The properties are suitable for the zoning amendments d. There is compatibility with the natural features of — and any archaeological or cultural resources on — the properties e. The Marketability of the properties that would be positively affected by the amendment; and f. There are roads, sewer, water, and stormwater facilities generally suitable and adequate to provide services for the affected properties. Staff Recommendation: Approve Rezoning request. 10.19.2026 www.allisonramseyarchitect.com a l l i s o n r a m s e y creating sustainable timeless designArchitects Inc. (843) 986-0559 1003 Charles St. Beaufort SC, 29902 THE ANCHORAGE Copyright 2026 by Allison Ramsey Architects, Inc. All rights reserved. THE ANCHORAGE www.allisonramseyarchitect.com a l l i s o n r a m s e y creating sustainable timeless designArchitects Inc. (843) 986-0559 1003 Charles St. Beaufort SC, 29902 THE ANCHORAGE Copyright 2026 by Allison Ramsey Architects, Inc. All rights reserved. www.allisonramseyarchitect.com a l l i s o n r a m s e y creating sustainable timeless designArchitects Inc. (843) 986-0559 1003 Charles St. Beaufort SC, 29902 THE ANCHORAGE Copyright 2026 by Allison Ramsey Architects, Inc. All rights reserved. www.allisonramseyarchitect.com a l l i s o n r a m s e y creating sustainable timeless designArchitects Inc. (843) 986-0559 1003 Charles St. Beaufort SC, 29902 THE ANCHORAGE Copyright 2026 by Allison Ramsey Architects, Inc. All rights reserved. www.allisonramseyarchitect.com a l l i s o n r a m s e y creating sustainable timeless designArchitects Inc. (843) 986-0559 1003 Charles St. Beaufort SC, 29902 THE ANCHORAGE Copyright 2026 by Allison Ramsey Architects, Inc. All rights reserved. www.allisonramseyarchitect.com a l l i s o n r a m s e y creating sustainable timeless designArchitects Inc. (843) 986-0559 1003 Charles St. Beaufort SC, 29902 THE ANCHORAGE Copyright 2026 by Allison Ramsey Architects, Inc. All rights reserved. www.allisonramseyarchitect.com a l l i s o n r a m s e y creating sustainable timeless designArchitects Inc. (843) 986-0559 1003 Charles St. Beaufort SC, 29902 THE ANCHORAGE Copyright 2026 by Allison Ramsey Architects, Inc. All rights reserved. www.allisonramseyarchitect.com a l l i s o n r a m s e y creating sustainable timeless designArchitects Inc. (843) 986-0559 1003 Charles St. Beaufort SC, 29902 THE ANCHORAGE Copyright 2026 by Allison Ramsey Architects, Inc. All rights reserved. www.allisonramseyarchitect.com a l l i s o n r a m s e y creating sustainable timeless designArchitects Inc. (843) 986-0559 1003 Charles St. Beaufort SC, 29902 THE ANCHORAGE Copyright 2026 by Allison Ramsey Architects, Inc. All rights reserved. STAFF REPORT: PLANNING COMMISSION (PC) – Preliminary Plat and Conceptual Site Plan 69 Meridian Townhouses DATE: 11/16/26 1 BACKGROUND The Applicant is requesting approval of a prel iminary plat and major site plan review for the development of 21 townhouses on 1.7 acre s. Formerly the lot ha d 13 mobile homes. The project is zoned T4-N and located of f of Meridian Road and Youmans Drive on Lady’s Island. GENERAL INFORMATION Applicant: Tim Brutcher, agent for Jeff Wheeler/Wheeler and Wheeler Site Address / Tax PIN: 69 Meridian ;R123-015-000-156A-0000; R 123-015-000-0000 Applicant's Request: Applicant is requesting approval of a preliminary plat and major site plan approval for the development of 21 townhouses on 1.7 acres located off of Meridian Road, and conceptual review of a site plan. Current Zoning: T4-N both lots Current Land Use: Vacant Flood Zone/Base Flood: Flood Zone: X, Elevations: 15-16 feet (Base-Flood Elevation: > 13 ft.) Existing Landmark/Specimen Trees: Retain all Landmark and Specimen Trees Including a 27” and 42 “ Livo Oak and 31” Laurel Oak; removal of 30”, 36”, 37” and 38” Laurel Oaks ZONING DISTRICT INFORMATION T4-N Neighborhood Minimum Lot Width: None Required Frontage Build Out 60% min; 85% max Minimum Lot Size: None Required Max Impervious Lot Coverage: 70% Lot Coverage Front Setback 0’ min, 15’ max Side Setback Corner/Alley: 10’ max Interior: 5 ft min Attached: 0’ Rear Setback 10 ft min; 0 ft from Alley Building Height: 2 stories min; 4 stories max SURROUNDING ZONING, LAND USE AND REQUIRED BUFFERS Adjacent Zoning Adjacent Land Uses Required Buffer type(s) - see Sec. 5.4.1; 5.4.2; 5.4.3) North: City IC High School N/A South: County T-3 N Houses Type D East: County T3-HN Houses/Trailers Type D West: County T-3 Edge/City: T3-S Homes N/A 2 TRC Meetings The project has bee n in review for some time, with a pre -application TRC meeting held in 2023, with a f ormal submittal made in October 2025, a revised submittal in August 2026, and then this final submittal in October of 2026. The comments for the last two TRC submittals are attached. Traffic/Road Access: With 21 townhouses, the project does not qualify under Section 7.3.2 for a Traffic Impact Analysis. A TIA is triggered with 50 peak hour trips, which this project would fall well under. However, Staff did coordinate traffic and street comments with County Engineering, and the developer obtained SCDOT approval for their proposed access plan. Access to the project will be provided by a f ull access off of Youmans Drive and Carolyn Drive. The Townhouses orient towards Youman’s Drive, and a 24’ wide rear drive provides access from the main entrance on Youman’s Drive to the secondary entrance on Carolyn Drive, with additional street parking along the southern boundary of this access drive. The T-4 N district requires curb and gutter, street trees, and lights all within all roads accessing the development. While the developer has received approvals with SCDOT, and relocated the sidewalk, it would not meet all of the requirements of Section 7.1.3. In addition, both Carolyn Drive as a secondary access road as well as Youman’s Drive are very narrow streets which could be impacted by any additional neighborhood traffic coming from this proposed development. Staff believ es i t may be warranted looking into the option of providing a separate turn lane from Youman’s Drive and also to widen that section of Carolyn Drive affected by the new development. The developer has responded that SCDOT has approved their plans and does not desire any improvements in their ROW. Sidewalks Sidewalks are provided alo ng Youmans and Meridian Road, but not within the ROW. The State denied an encroachment permit for the sidewalks, requiring the shift to the private property. Currently, there are no other sidewalks in this area. Open Space: As per Sect ion 7.4.2, p rojects in the T4 _N district require 10% open space for 3 acres or more ( with a gradua l increasing scale based on size of the development) . If under 3 acres, like this project, open space is at the discretion of the Planning Commission. In this case, the Applicant is still providing the 10% open space , preserving the areas around the two landmark live oak trees. Staff finds this to be sufficient and in keeping with the intent of the code. Tree Removal / Mitigation / Canopy Coverage Proposed: The applicant is retaining the major specimen and landmark trees on both properties. The 27” and 42” inch live oak make are preserved in the primary entrance off Youmans Drive. In addition, a 31” Laurel Oak and a handful of Pines, etc. are preserved along the Southern property line. The applicant is proposing the 3 removal of specimen 30”, 36”, 37” and 38” Laurel Oaks, and a number of smaller trees which do not trigger protected specimen or landmark status. The applicant is mitigating the removal with the replanting of trees along the boundary areas of the project, and with planned and existing trees, is proposing 56.16% of the area will be within a tree canopy, well above the 25% requirement for such a project per the Development Code. Required Buffer Areas Section 5.4.3 states: “All residential developments shall have a Type D rear and side yard buffer where an adjoining use is other than that same residential type, unless a different buffer requirement is imposed by the Planning Commission.” The adjoining properties to the South are T3-N in the County, and T3-HN. Both districts allow residential, but do not allow attached single family or townhouses. With this requirement, a 20’-30’ buffer is required along the Southern and Eastern Property line. Currently, the buffer along the South is landscaped, but minimal (3’). In addition, it does not appear the proposed layout or product would be viable without some waiver by the Planning Commission. The mass, height, scale and density of these townhouses would be far greater than what exists in this area, thus some break or buffer must be considered. FUTURE LAND USE: The area is categorized as General Urban by the Comprehensive Plan, and the Comprehensive Plan depicts both lots as General Urban in character. The project is consistent with the Comprehensive Plan. PRELIMINARY PLAT FINDINGS (SECTION 7.5.4 D) 4 Finding of Fact 7.5.4 D Rationale Present (yes/no) Staff Analysis of Rationale 1. The Preliminary Plat is consistent with the rationale and criteria set forth in this Code Partially/ Requires conditions  The project is consistent with plans and policies of the City.  The developer has incorporated the majority of staff comments, as well as concerns over open space, trees, density, height, access, thru access, and stormwater into the current request. x. The rear and side buffer area as per Section 5.4.3 would not be met with the current plan. 2. The land use mix within the project conforms to the City’s Development Code and complies with the Comprehensive Plan and Civic Master Plan” Yes  Townhomes provide density and general urban character desired by the development code and comprehensive plan. 3. The utility and transportation design are adequate, given existing and planned capacities of those systems” Not fully met/Met with conditions  Access from Carolyn and Youmans create for rear loaded lots and within the required site distances for access points x. Staff proposed increasing the ROW width or pavement width of Youmans Drive and Carolyn Drive, but SCDOT found the current width to be sufficient. x. The T-4 N district requires curb and gutter, street trees, and lights all within all roads accessing the development. While the developer has received approvals with SCDOT, and relocated the sidewalk, it would not meet all of the requirements of Section 7.1.3  There is existing water, sewer, stormwater and electric utilities to support the plan. 5 4. “Lot layout, including structure, location, and design of each lot”: Partially met/ Requires Conditions  The developer is providing sidewalks on their property, and additional guest parking.  The design saves the primary landmark and specimen trees.  The layout of the townhouses along Meridian and Youmans corresponds with the requirements of the code. x. Again, The rear and side buffer area as per Section 5.4.3 would not be met with the current plan, and due to the layout and narrowness of the parcels, the Planning Commission should consider whether an alternative buffer is appropriate. Major Site Plan Comments As an attached product with over 5 units, as per Section 9.8.2 it must follow the major site plan requirements of Section 7.5.7. While the majority of improvements (from stormwater, to landscaping, etc which would be owned and maintained in common by the POA/HOA) are handled by the Preliminary Plat process, a few remain, most importantly architecture and design. General Site Design: The front of the units facing Youmans, will look out the high school baseb all field, which is lit for night games. There is no buffering for said lights or noise when the ballpark is in use, and due to the narrowness of the ROW, not much screening possible in the future. Architecture: The project has been reviewed by Meadors and Staff, with outstanding unresolved comments found below. The central theme of the comments has been 1) the height and length of the structures compared to the surrounding neighborhood, 2) Requiring some change in design to separate and define each set of units (there 5 total) as different, especially with the long expanse of Youmans Drive, 3) refining the architectural details.  The townhomes measure almost 46’ tall from ground to top of ridge, which seems tall considering all surrounding lots except on the water side are one storey. The primary gable forms seems especially prominent and visible on the front façade. Staff recommends reducing the slope of the main roof. 6  Staff is not supportive of the projecting brick sill and veneer that extends several inches beyond the siding wall plane. Staff recommends the applicant consider thin brick or stucco to keep the keep the wall planes in line with one another.  Many of the renderings that show the rear/garage view, indicate a lap siding cladding in the pedestrian door alcove/recess and brick veneer around the garage doors. Those alcoves/recesses should also be brick veneer for consistent architectural language around the building base. Floor plans at grade level shall be revised to reflect the brick veneer cladding into these alcoves/recesses for all buildings.  Applicant to provide material cutsheets. This includes windows, doors, roofing, cladding, exterior lighting, etc. All relevant selections should be circled on the cutsheets. No cutsheets provided yet.  Staff is not supportive of the blank areas of wall between the gables on the rear façade. Staff recommends adding windows in these areas – the interior configuration may need to be restudied.  The bays with triple-ganged windows do not have interior cornerboards. 7.5.7 D. 3 Finding of Fact Rationale Present (yes/no) Staff Analysis of Rationale a. The plan is consistent with the City of Beaufort Comprehensive Plan and Civic Master Plan. Yes  The project is consistent with plans and policies of the City. b. The plan complies with all applicable requirements of this Code. Partially Met/Conditions  The developer has incorporated the majority of staff comments, as well as concerns over open space, trees, density, height, access, thru access, and stormwater into the current request. x. The T-4 N district requires curb and gutter, street trees, and lights all within all roads accessing the development. While the developer has received approvals with SCDOT, and relocated the sidewalk, it would not meet all of the requirements of Section 7.1.3 c. There exists adequate infrastructure (transportation Partially Met  There is existing water, sewer, stormwater and electric utilities to support the plan. 7 and utilities) to support the plan as proposed. x. Staff proposed increasing the ROW width or pavement width of Youmans Drive and Carolyn Drive, but SCDOT found the current width to be sufficient. d. The plan conforms to the character of the neighborhood, considering the location, type and height of buildings or structures and the type and extent of landscaping on the site. Not met/requires conditions  The applicant has made efforts to buffer the street and to the Southern property line which has a dissimilar use. x. There are no townhouses similar to what is proposed in this general vicinity. x. Staff has concerns with the fact these lots front an athletic field with no established buffer but a chain link fence. The fronts of the townhouses will look directly at the baseball field, which may be lit numerous nights each year. There is no mitigation for this light onto the townhouses. x. Staff has concerns regarding the height, as no heights similar to this project exist on this side of the street. FINDINGS AND RECOMMENDATIONS Staff recommends Tabling the Project in that it does not currently satisfy the requirements of Section 7.5.4 D and Section 7.5.7 D 3 with the following recommendations: 1) Study the height of the buildings, with a recommendation of 35’ at a maximum due to the rhythm, scale and massing of the surrounding neighborhood. 2) Study improvements to Youmans Drive and Carolyn Drive, such as widening, street parking, curb and gutter, etc, as per Section 7.1.3. 3) Study adding an additional buffer area, and/or improved screening to the South. 8 4) Provide cut sheets and final materials. 5) Consider architectural comments found on pages 5-6 of this staff report. VICINITY MAP I HAVE PLACED MY SIGNATURE AND SEAL ON THE DESIGN DOCUMENTS SUBMITTED SIGNIFYING THAT I ACCEPT RESPONSIBILITY FOR THE DESIGN OF THE SYSTEM. FURTHER, I CERTIFY TO THE BEST OF MY KNOWLEDGE AND BELIEF THE THE DESIGN IS CONSISTENT WITH THE REQUIREMENTS OF TITLE 48, CHAPTER 14 OF THE CODE OF LAWS OF SC, 1976 AS AMENDED, PURSUANT TO REGULATION 72-300 ET SEQ. (IF APPLICABLE), AND IN ACCORDANCE WITH THE TERMS AND CONDITIONS OF SCR100000. TITLE SHEET1 SHEET NO. DESCRIPTION of 11 SCHEDULE OF DRAWINGS of 2 of of 3 4 TREE REMOVAL & PROTECTION AND SEDIMENT & EROSION CONTROL PLAN of of 5 6 SEDIMENT & EROSION CONTROL DETAILS PAVING, GRADING & DRAINAGE PLAN WATER & SANITARY SEWER PLAN PAVING, GRADING & DRAINAGE DETAILS APPROXIMATE LOCATION OF SITE SITE of of 7 SANITARY SEWER DETAILS 8 PHONE (843)322-0553 WWW.CAROLINAENGINEERING.COMPO BOX 294 BEAUFORT, SC 29901 CAROLINA ENGINEERING CONSULTANTS, INC. TAX MAP# R123-015-000-156A-0000 R123-015-000-0156-000 69 MERIDIAN ROAD BEAUFORT, SC 29907 LATITUDE 32° 24' 46" LONGITUDE 80° 39' 46" HORIZONTAL DATUM NAVD88 - VERTICAL DATUM NAD83 800 CONGRESS ST BEAUFORT, SC 29902 SITE DEVELOPMENT PLANS 69 MERIDIAN ROAD CITY OF BEAUFORT, SC 21 LOTS #1-21 RESIDENTIAL PREPARED BY: DEVELOPER: WHEELER & WHEELER 1711 GERVIAS STREET COLUMBIA, SC 29201ADDRESS: JEFF WHEELER/JBWREALESTATE@GMAIL.COM SITE MERIDIAN ROAD YOUMANS DRIVE SCALE: 1"=3000' GENERAL NOTES & LEGEND SHEET CONTACT: 69 MERIDIAN ROADBJWSA 2024-141 EXISTING CONDITIONS & DEMOLITION SHEET of 9 11 11 11 11 11 11 11 11 ISSUED FOR: PERMITTING PROJECT:REVISED:DATE: 05/15/24 04/21/25 2294 XX/XX/XX RUE DU BOIS LADY'S ISLAND DRIVE SEA ISLAND PARKWAY SANITARY SEWER PROFILEof 11 11 WATER DETAILSof 10 11 ENCROACHMENT PLANof 1 1 04/21/2025 GENERAL NOTES & LEGEND 2 OF 11 SEDIMENT & EROSION CONTROL NOTES: IF fi fl fi GENERAL: PAVING, GRADING, & DRAINAGE NOTES: WATER, & SANITARY SEWER NOTES: GENERAL: GENERAL SCDOT NOTES: CALL 1-888-721-7877 LINE LEGEND: TREE IDENTIFICATION SYMBOL LEGEND: REMOVE TREE LEGEND REMAIN ABBREVIATIONS TREE PROTECTION & REMOVAL NOTES: 843/322-0553 843/322-0556 (FAX) CAROLINA ENGINEERING CONSULTANTS, INC. PO BOX 294 BEAUFORT, SC 29901WWW.CAROLINAENGINEERING.COM - 6 - DESCRIPTION PLAN REVISIONS NO. 3 2 1 4 5 - - - - - DATE - - - - - 8 7 - - - - *ANY INFRINGEMENT MAY BE SUBJECT TO LEGAL ACTION. THE DESIGNS AND IDEAS PRESENTED IN THESE DRAWINGS ARE THE PROPERTY OF SAID ENGINEER. THE REPRODUCTION, COPY, OR USE OF THESE PLANS OR THE INFORMATION IS STRICTLY PROHIBITED WITHOUT THE WRITTEN CONSENT OF THE ENGINEER. PROJECT: DATE: REVISED: DRAWN BY: ENGINEER: SCALE: NTS JPA RGG 04/21/25 05/14/24 2294 V-DATUM: NAVD 88 69 MERIDIAN ROAD LADY'S ISLAND BEAUFORT COUNTY, SC H-DATUM: NAD 83 SHT #6 SHT #5 SURVEYOR: ELECTRICITY PROVIDER: TELECOMMUNICATIONS: WATER & SANITARY SEWER: 04/21/2025 N/F BEAUFORT COUNTY SCHOOL DISTRICT N/F LEE FRAISER N/F SHELDON 123 LLC N/F BEAUFORT COUNTY SCHOOL DISTRICT N/F RICHARD KIRKLAND N/F LARRY KIRKLAND N/F 66 MERIDIAN ROAD LLC N/F 64 MERIDIAN ROAD LLC YOUMANS DRIVE (S-7-266) SCDOT OWNED MERIDIAN ROAD (S-36) SCDOT OWNED CAROLYN DRIVE 30' R/W (LOCAL) RUN DEMO LMAN EXISTING CONDITIONS & DEMOLITION PLAN 3 843/322-0553 843/322-0556 (FAX) CAROLINA ENGINEERING CONSULTANTS, INC. PO BOX 294 BEAUFORT, SC 29901WWW.CAROLINAENGINEERING.COM - 6 - DESCRIPTION PLAN REVISIONS NO. 3 2 1 4 5 - - - - - DATE - - - - - 8 7 - - - - *ANY INFRINGEMENT MAY BE SUBJECT TO LEGAL ACTION. THE DESIGNS AND IDEAS PRESENTED IN THESE DRAWINGS ARE THE PROPERTY OF SAID ENGINEER. THE REPRODUCTION, COPY, OR USE OF THESE PLANS OR THE INFORMATION IS STRICTLY PROHIBITED WITHOUT THE WRITTEN CONSENT OF THE ENGINEER. 69 MERIDIAN ROAD LADY'S ISLAND BEAUFORT COUNTY, SC PROJECT: DATE: REVISED: DRAWN BY: ENGINEER: SCALE: 1"=30' JPA RGG 05/14/24 2294 V-DATUM: NAVD 88 H-DATUM: NAD 83 OF 11 04/21/25 04/21/2025 Ds3 Ds1 Sd2 Sd2 Sd2 Sd2 Sd2 Sd1 Sd1 Sd1 Sd1 Sd1 Sd1 Sd1 Ds3 Ds1 Ds3 Ds1 Ds3 Ds1Ds3 Ds1 Ds3 Ds1 Ds3 Ds1 Ds3 Ds1 Ds3 Ds1 Cw N/F BEAUFORT COUNTY SCHOOL DISTRICT N/F LEE FRAISER N/F SHELDON 123 LLC N/F BEAUFORT COUNTY SCHOOL DISTRICT N/F RICHARD KIRKLAND N/F LARRY KIRKLAND N/F 66 MERIDIAN ROAD LLC N/F 64 MERIDIAN ROAD LLC YOUMANS DRIVE (S-7-266) SCDOT OWNED MERIDIAN ROAD (S-36) SCDOT OWNED CAROLYN DRIVE 30' R/W (LOCAL) Co RUN TREESEC LMAN TREE REMOVAL & PROTECTION AND SEDIMENT & EROSION CONTROL PLAN 4 843/322-0553 843/322-0556 (FAX) CAROLINA ENGINEERING CONSULTANTS, INC. PO BOX 294 BEAUFORT, SC 29901WWW.CAROLINAENGINEERING.COM - 6 - DESCRIPTION PLAN REVISIONS NO. 3 2 1 4 5 - - - - - DATE - - - - - 8 7 - - - - *ANY INFRINGEMENT MAY BE SUBJECT TO LEGAL ACTION. THE DESIGNS AND IDEAS PRESENTED IN THESE DRAWINGS ARE THE PROPERTY OF SAID ENGINEER. THE REPRODUCTION, COPY, OR USE OF THESE PLANS OR THE INFORMATION IS STRICTLY PROHIBITED WITHOUT THE WRITTEN CONSENT OF THE ENGINEER. 69 MERIDIAN ROAD LADY'S ISLAND BEAUFORT COUNTY, SC PROJECT: DATE: REVISED: DRAWN BY: ENGINEER: SCALE: 1"=30' JPA RGG 05/14/24 2294 V-DATUM: NAVD 88 H-DATUM: NAD 83 OF 11 04/21/25 04/21/2025 MULCHING NOTES BfBf Cs Ds1 Du Ds1 Cs Ds1 Ds2 Du Ds3 VEGETATIVE MEASURES DETAILCODE PRACTICE SYMBOL MAP DESCRIPTION Ds2 Ds3 Sd1 SEDIMENT BARRIERS LOT SILT FENCE PLAN CONCRETE WASHOUT SIGN DETAIL SECTION B-B NOT TO SCALE SECTION A-A NOT TO SCALE PLAN TYPE "EXCAVATED PIT" NOTES: 1. ACTUAL LAYOUT DETERMINED IN FIELD. 2. INSTALL CONCRETE WASHOUT SIGN (24"X24", MINIMUM) WITHIN 30' OF THE TEMPORARY CONCRETE WASHOUT FACILITY. 3. TEMPORARY WASHOUT AREA MUST BE AT LEAST 50' FROM A STORM DRAIN, CREEK BANK OR PERIMETER CONTROL. 4. CLEAN OUT CONCRETE WASHOUT AREA WHEN 50% FULL. 5. THE KEY TO FUNCTIONAL CONCRETE WASHOUTS IS WEEKLY INSPECTIONS, ROUTINE MAINTENANCE, AND REGULAR CLEAN OUT. 6. SILT FENCE SHALL BE INSTALLED AROUND PERIMETER OF CONCRETE WASHOUT AREA EXCEPT FOR THE SIDE UTILIZED FOR ACCESSING THE WASHOUT. 7. A ROCK CONSTRUCTION ENTRANCE MAY BE NECESSARY ALONG ONE SIDE OF THE WASHOUT TO PROVIDE VEHICLE ACCESS. CONCRETE WASHOUT Cw CONCRETE WASHOUT UNPAVED APPLICATION PAVED APPLICAITON Sd2 CATCH BASIN SEDIMENT BARRIER 14 13 12 SCHEDULE 9 11 10 7 6 8 5 4 3 2 1 ACTIVITY SCHEDULE ACTIVITY Co STONE PAD CONSTRUCTION EXIT SEDIMENT & EROSION CONTROL DETAILS 5 843/322-0553 843/322-0556 (FAX) CAROLINA ENGINEERING CONSULTANTS, INC. PO BOX 294 BEAUFORT, SC 29901WWW.CAROLINAENGINEERING.COM - 6 - DESCRIPTION PLAN REVISIONS NO. 3 2 1 4 5 - - - - - DATE - - - - - 8 7 - - - - *ANY INFRINGEMENT MAY BE SUBJECT TO LEGAL ACTION. THE DESIGNS AND IDEAS PRESENTED IN THESE DRAWINGS ARE THE PROPERTY OF SAID ENGINEER. THE REPRODUCTION, COPY, OR USE OF THESE PLANS OR THE INFORMATION IS STRICTLY PROHIBITED WITHOUT THE WRITTEN CONSENT OF THE ENGINEER. 69 MERIDIAN ROAD LADY'S ISLAND BEAUFORT COUNTY, SC PROJECT: DATE: REVISED: DRAWN BY: ENGINEER: SCALE: NTS JPA RGG 05/15/24 2294 V-DATUM: NAVD 88 H-DATUM: NAD 83 OF 11 04/21/25 04/21/2025 N/F BEAUFORT COUNTY SCHOOL DISTRICT N/F LEE FRAISER N/F SHELDON 123 LLC N/F BEAUFORT COUNTY SCHOOL DISTRICT N/F RICHARD KIRKLAND N/F LARRY KIRKLAND N/F 66 MERIDIAN ROAD LLC N/F 64 MERIDIAN ROAD LLC YOUMANS DRIVE (S-7-266) SCDOT OWNED MERIDIAN ROAD (S-36) SCDOT OWNED CAROLYN DRIVE 30' R/W (LOCAL) FFE=17.77 GARAGE=17.44 FFE=17.52 GARAGE=17.52FFE=17.57 FFE=16.98 GARAGE=16.98 RUN PGD LMAN PAVING, GRADING, & DRAINAGE PLAN 6 843/322-0553 843/322-0556 (FAX) CAROLINA ENGINEERING CONSULTANTS, INC. PO BOX 294 BEAUFORT, SC 29901WWW.CAROLINAENGINEERING.COM - 6 - DESCRIPTION PLAN REVISIONS NO. 3 2 1 4 5 - - - - - DATE - - - - - 8 7 - - - - *ANY INFRINGEMENT MAY BE SUBJECT TO LEGAL ACTION. THE DESIGNS AND IDEAS PRESENTED IN THESE DRAWINGS ARE THE PROPERTY OF SAID ENGINEER. THE REPRODUCTION, COPY, OR USE OF THESE PLANS OR THE INFORMATION IS STRICTLY PROHIBITED WITHOUT THE WRITTEN CONSENT OF THE ENGINEER. 69 MERIDIAN ROAD LADY'S ISLAND BEAUFORT COUNTY, SC PROJECT: DATE: REVISED: DRAWN BY: ENGINEER: SCALE: 1"=30' JPA RGG 05/14/24 2294 V-DATUM: NAVD 88 H-DATUM: NAD 83 OF 11 04/21/25 04/21/2025 STORM PIPE BEDDING YARD INLET 12" DRAIN BASIN PERVIOUS CONCRETE PAVING CONCRETE RIBBON CURB R1-1 STOP SIGN STOP BAR HEAVY DUTY ASPHALT PAVING DETAIL CATCH BASIN DETAIL CONCRETE SIDEWALK DETAIL ACCEPTABLE FILL MATERIALS: STORMTECH SC-740 CHAMBER SYSTEMS PLEASE NOTE: 1. THE LISTED AASHTO DESIGNATIONS ARE FOR GRADATIONS ONLY. THE STONE MUST ALSO BE CLEAN, CRUSHED, ANGULAR. FOR EXAMPLE, A SPECIFICATION FOR #4 STONE WOULD STATE: "CLEAN, CRUSHED, ANGULAR NO. 4 (AASHTO M43) STONE". 2. STORMTECH COMPACTION REQUIREMENTS ARE MET FOR 'A' LOCATION MATERIALS WHEN PLACED AND COMPACTED IN 6" (150 mm) (MAX) LIFTS USING TWO FULL COVERAGES WITH A VIBRATORY COMPACTOR. 3. WHERE INFILTRATION SURFACES MAY BE COMPROMISED BY COMPACTION, FOR STANDARD DESIGN LOAD CONDITIONS, A FLAT SURFACE MAY BE ACHIEVED BY RAKING OR DRAGGING WITHOUT COMPACTION EQUIPMENT. FOR SPECIAL LOAD DESIGNS, CONTACT STORMTECH FOR COMPACTION REQUIREMENTS. 4. ONCE LAYER 'C' IS PLACED, ANY SOIL/MATERIAL CAN BE PLACED IN LAYER 'D' UP TO THE FINISHED GRADE. MOST PAVEMENT SUBBASE SOILS CAN BE USED TO REPLACE THE MATERIAL REQUIREMENTS OF LAYER 'C' OR 'D' AT THE SITE DESIGN ENGINEER'S DISCRETION. NOTES: 1. CHAMBERS SHALL MEET THE REQUIREMENTS OF ASTM F2418, "STANDARD SPECIFICATION FOR POLYPROPYLENE (PP) CORRUGATED WALL STORMWATER COLLECTION CHAMBERS". 2. SC-740 CHAMBERS SHALL BE DESIGNED IN ACCORDANCE WITH ASTM F2787 "STANDARD PRACTICE FOR STRUCTURAL DESIGN OF THERMOPLASTIC CORRUGATED WALL STORMWATER COLLECTION CHAMBERS". 3. THE SITE DESIGN ENGINEER IS RESPONSIBLE FOR ASSESSING THE BEARING RESISTANCE (ALLOWABLE BEARING CAPACITY) OF THE SUBGRADE SOILS AND THE DEPTH OF FOUNDATION STONE WITH CONSIDERATION FOR THE RANGE OF EXPECTED SOIL MOISTURE CONDITIONS. 4. PERIMETER STONE MUST BE EXTENDED HORIZONTALLY TO THE EXCAVATION WALL FOR BOTH VERTICAL AND SLOPED EXCAVATION WALLS. 5. REQUIREMENTS FOR HANDLING AND INSTALLATION: · TO MAINTAIN THE WIDTH OF CHAMBERS DURING SHIPPING AND HANDLING, CHAMBERS SHALL HAVE INTEGRAL, INTERLOCKING STACKING LUGS. · TO ENSURE A SECURE JOINT DURING INSTALLATION AND BACKFILL, THE HEIGHT OF THE CHAMBER JOINT SHALL NOT BE LESS THAN 2”. · TO ENSURE THE INTEGRITY OF THE ARCH SHAPE DURING INSTALLATION, a) THE ARCH STIFFNESS CONSTANT AS DEFINED IN SECTION 6.2.8 OF ASTM F2418 SHALL BE GREATER THAN OR EQUAL TO 550 LBS/FT/%. AND b) TO RESIST CHAMBER DEFORMATION DURING INSTALLATION AT ELEVATED TEMPERATURES (ABOVE 73° F / 23° C), CHAMBERS SHALL BE PRODUCED FROM REFLECTIVE GOLD OR YELLOW COLORS. MATERIAL LOCATION DESCRIPTION AASHTO MATERIAL CLASSIFICATIONS COMPACTION / DENSITY REQUIREMENT D FINAL FILL: FILL MATERIAL FOR LAYER 'D' STARTS FROM THE TOP OF THE 'C' LAYER TO THE BOTTOM OF FLEXIBLE PAVEMENT OR UNPAVED FINISHED GRADE ABOVE. NOTE THAT PAVEMENT SUBBASE MAY BE PART OF THE 'D' LAYER. ANY SOIL/ROCK MATERIALS, NATIVE SOILS, OR PER ENGINEER'S PLANS. CHECK PLANS FOR PAVEMENT SUBGRADE REQUIREMENTS. N/A PREPARE PER SITE DESIGN ENGINEER'S PLANS. PAVED INSTALLATIONS MAY HAVE STRINGENT MATERIAL AND PREPARATION REQUIREMENTS. C INITIAL FILL: FILL MATERIAL FOR LAYER 'C' STARTS FROM THE TOP OF THE EMBEDMENT STONE ('B' LAYER) TO 18" (450 mm) ABOVE THE TOP OF THE CHAMBER. NOTE THAT PAVEMENT SUBBASE MAY BE A PART OF THE 'C' LAYER. GRANULAR WELL-GRADED SOIL/AGGREGATE MIXTURES, <35% FINES OR PROCESSED AGGREGATE. MOST PAVEMENT SUBBASE MATERIALS CAN BE USED IN LIEU OF THIS LAYER. AASHTO M145¹ A-1, A-2-4, A-3 OR AASHTO M43¹ 3, 357, 4, 467, 5, 56, 57, 6, 67, 68, 7, 78, 8, 89, 9, 10 BEGIN COMPACTIONS AFTER 12" (300 mm) OF MATERIAL OVER THE CHAMBERS IS REACHED. COMPACT ADDITIONAL LAYERS IN 6" (150 mm) MAX LIFTS TO A MIN. 95% PROCTOR DENSITY FOR WELL GRADED MATERIAL AND 95% RELATIVE DENSITY FOR PROCESSED AGGREGATE MATERIALS. ROLLER GROSS VEHICLE WEIGHT NOT TO EXCEED 12,000 lbs (53 kN). DYNAMIC FORCE NOT TO EXCEED 20,000 lbs (89 kN). B EMBEDMENT STONE: FILL SURROUNDING THE CHAMBERS FROM THE FOUNDATION STONE ('A' LAYER) TO THE 'C' LAYER ABOVE. CLEAN, CRUSHED, ANGULAR STONE AASHTO M43¹ 3, 357, 4, 467, 5, 56, 57 NO COMPACTION REQUIRED. A FOUNDATION STONE: FILL BELOW CHAMBERS FROM THE SUBGRADE UP TO THE FOOT (BOTTOM) OF THE CHAMBER. CLEAN, CRUSHED, ANGULAR STONE AASHTO M43¹ 3, 357, 4, 467, 5, 56, 57 PLATE COMPACT OR ROLL TO ACHIEVE A FLAT SURFACE.2,3 18" (450 mm) MIN* 8' (2.4 m) MAX 6" (150 mm) MIN D C B A 12" (300 mm) MIN ADS GEOSYNTHETICS 601T NON-WOVEN GEOTEXTILE ALL AROUND CLEAN, CRUSHED, ANGULAR STONE IN A & B LAYERS 12" (300 mm) MIN51" (1295 mm)6" (150 mm) MIN 30" (762 mm) DEPTH OF STONE TO BE DETERMINED BY SITE DESIGN ENGINEER 6" (150 mm) MIN *TO BOTTOM OF FLEXIBLE PAVEMENT. FOR UNPAVED INSTALLATIONS WHERE RUTTING FROM VEHICLES MAY OCCUR, INCREASE COVER TO 24" (600 mm). EXCAVATION WALL (CAN BE SLOPED OR VERTICAL) PERIMETER STONE (SEE NOTE 4) SC-740 END CAP SUBGRADE SOILS (SEE NOTE 3) PAVEMENT LAYER (DESIGNED BY SITE DESIGN ENGINEER) PART # STUB A B C SC740EPE06T / SC740EPE06TPC 6" (150 mm) 10.9" (277 mm) 18.5" (470 mm) --- SC740EPE06B / SC740EPE06BPC --- 0.5" (13 mm) SC740EPE08T /SC740EPE08TPC 8" (200 mm) 12.2" (310 mm) 16.5" (419 mm) --- SC740EPE08B / SC740EPE08BPC --- 0.6" (15 mm) SC740EPE10T / SC740EPE10TPC 10" (250 mm) 13.4" (340 mm) 14.5" (368 mm) --- SC740EPE10B / SC740EPE10BPC --- 0.7" (18 mm) SC740EPE12T / SC740EPE12TPC 12" (300 mm) 14.7" (373 mm) 12.5" (318 mm) --- SC740EPE12B / SC740EPE12BPC --- 1.2" (30 mm) SC740EPE15T / SC740EPE15TPC 15" (375 mm) 18.4" (467 mm) 9.0" (229 mm) --- SC740EPE15B / SC740EPE15BPC --- 1.3" (33 mm) SC740EPE18T / SC740EPE18TPC 18" (450 mm) 19.7" (500 mm) 5.0" (127 mm) --- SC740EPE18B / SC740EPE18BPC --- 1.6" (41 mm) SC740EPE24B* 24" (600 mm) 18.5" (470 mm) --- 0.1" (3 mm) ALL STUBS, EXCEPT FOR THE SC740EPE24B ARE PLACED AT BOTTOM OF END CAP SUCH THAT THE OUTSIDE DIAMETER OF THE STUB IS FLUSH WITH THE BOTTOM OF THE END CAP. FOR ADDITIONAL INFORMATION CONTACT STORMTECH AT 1-888-892-2694. * FOR THE SC740EPE24B THE 24" (600 mm) STUB LIES BELOW THE BOTTOM OF THE END CAP APPROXIMATELY 1.75" (44 mm). BACKFILL MATERIAL SHOULD BE REMOVED FROM BELOW THE N-12 STUB SO THAT THE FITTING SITS LEVEL. NOTE: ALL DIMENSIONS ARE NOMINAL NOMINAL CHAMBER SPECIFICATIONS SIZE (W X H X INSTALLED LENGTH) 51.0" X 30.0" X 85.4" (1295 mm X 762 mm X 2169 mm) CHAMBER STORAGE 45.9 CUBIC FEET (1.30 m³) MINIMUM INSTALLED STORAGE* 74.9 CUBIC FEET (2.12 m³) WEIGHT 75.0 lbs. (33.6 kg) *ASSUMES 6" (152 mm) STONE ABOVE, BELOW, AND BETWEEN CHAMBERS STUBS AT BOTTOM OF END CAP FOR PART NUMBERS ENDING WITH "B" STUBS AT TOP OF END CAP FOR PART NUMBERS ENDING WITH "T" SC-740 TECHNICAL SPECIFICATION NTS 90.7" (2304 mm) ACTUAL LENGTH 85.4" (2169 mm) INSTALLED LENGTH OVERLAP NEXT CHAMBER HERE (OVER SMALL CORRUGATION) BUILD ROW IN THIS DIRECTION START END A A C B 51.0" (1295 mm) 30.0" (762 mm) ACCEPTS 4" (100 mm) SCH 40 PVC PIPE FOR INSPECTION PORT. FOR PIPE SIZES LARGER THAN 4" (100 mm) UP TO 10" (250 mm) USE INSERTA TEE CONNECTION CENTERED ON A CHAMBER CREST CORRUGATION 45.9" (1166 mm)12.2" (310 mm) 29.3" (744 mm) CUT & PATCH SCDOT PAVEMENT DETAIL GRASS SWALE DETAIL PAVING, GRADING & DRAINAGE DETAILS 7 843/322-0553 843/322-0556 (FAX) CAROLINA ENGINEERING CONSULTANTS, INC. PO BOX 294 BEAUFORT, SC 29901WWW.CAROLINAENGINEERING.COM - 6 - DESCRIPTION PLAN REVISIONS NO. 3 2 1 4 5 - - - - - DATE - - - - - 8 7 - - - - *ANY INFRINGEMENT MAY BE SUBJECT TO LEGAL ACTION. THE DESIGNS AND IDEAS PRESENTED IN THESE DRAWINGS ARE THE PROPERTY OF SAID ENGINEER. THE REPRODUCTION, COPY, OR USE OF THESE PLANS OR THE INFORMATION IS STRICTLY PROHIBITED WITHOUT THE WRITTEN CONSENT OF THE ENGINEER. 69 MERIDIAN ROAD LADY'S ISLAND BEAUFORT COUNTY, SC PROJECT: DATE: REVISED: DRAWN BY: ENGINEER: SCALE: NTS JPA RGG 05/15/24 2294 V-DATUM: NAVD 88 H-DATUM: NAD 83 OF 11 04/21/25 04/21/2025 N/F BEAUFORT COUNTY SCHOOL DISTRICT N/F LEE FRAISER N/F SHELDON 123 LLC N/F BEAUFORT COUNTY SCHOOL DISTRICT N/F RICHARD KIRKLAND N/F LARRY KIRKLAND N/F 66 MERIDIAN ROAD LLC N/F 64 MERIDIAN ROAD LLC YOUMANS DRIVE (S-7-266) SCDOT OWNED MERIDIAN ROAD (S-36) SCDOT OWNED CAROLYN DRIVE 30' R/W (LOCAL) RUN WTRSAN LMAN WATER & SANITARY SEWER PLAN 8 843/322-0553 843/322-0556 (FAX) CAROLINA ENGINEERING CONSULTANTS, INC. PO BOX 294 BEAUFORT, SC 29901WWW.CAROLINAENGINEERING.COM - 6 - DESCRIPTION PLAN REVISIONS NO. 3 2 1 4 5 - - - - - DATE - - - - - 8 7 - - - - *ANY INFRINGEMENT MAY BE SUBJECT TO LEGAL ACTION. THE DESIGNS AND IDEAS PRESENTED IN THESE DRAWINGS ARE THE PROPERTY OF SAID ENGINEER. THE REPRODUCTION, COPY, OR USE OF THESE PLANS OR THE INFORMATION IS STRICTLY PROHIBITED WITHOUT THE WRITTEN CONSENT OF THE ENGINEER. 69 MERIDIAN ROAD LADY'S ISLAND BEAUFORT COUNTY, SC PROJECT: DATE: REVISED: DRAWN BY: ENGINEER: SCALE: 1"=30' JPA RGG 05/14/24 2294 V-DATUM: NAVD 88 H-DATUM: NAD 83 OF 11 04/21/25 04/21/2025 SANITARY SEWER DETAILS 843/322-0553 843/322-0556 (FAX) CAROLINA ENGINEERING CONSULTANTS, INC. PO BOX 294 BEAUFORT, SC 29901WWW.CAROLINAENGINEERING.COM - 6 - DESCRIPTION PLAN REVISIONS NO. 3 2 1 4 5 - - - - - DATE - - - - - 8 7 - - - - *ANY INFRINGEMENT MAY BE SUBJECT TO LEGAL ACTION. THE DESIGNS AND IDEAS PRESENTED IN THESE DRAWINGS ARE THE PROPERTY OF SAID ENGINEER. THE REPRODUCTION, COPY, OR USE OF THESE PLANS OR THE INFORMATION IS STRICTLY PROHIBITED WITHOUT THE WRITTEN CONSENT OF THE ENGINEER. 9 69 MERIDIAN ROAD LADY'S ISLAND BEAUFORT COUNTY, SC PROJECT: DATE: REVISED: DRAWN BY: ENGINEER: SCALE: NTS JPA RGG 05/15/24 2294 V-DATUM: NAVD 88 H-DATUM: NAD 83 OF 11 04/21/25 WATER DETAILS 10 843/322-0553 843/322-0556 (FAX) CAROLINA ENGINEERING CONSULTANTS, INC. PO BOX 294 BEAUFORT, SC 29901WWW.CAROLINAENGINEERING.COM - 6 - DESCRIPTION PLAN REVISIONS NO. 3 2 1 4 5 - - - - - DATE - - - - - 8 7 - - - - *ANY INFRINGEMENT MAY BE SUBJECT TO LEGAL ACTION. THE DESIGNS AND IDEAS PRESENTED IN THESE DRAWINGS ARE THE PROPERTY OF SAID ENGINEER. THE REPRODUCTION, COPY, OR USE OF THESE PLANS OR THE INFORMATION IS STRICTLY PROHIBITED WITHOUT THE WRITTEN CONSENT OF THE ENGINEER. 69 MERIDIAN ROAD LADY'S ISLAND BEAUFORT COUNTY, SC PROJECT: DATE: REVISED: DRAWN BY: ENGINEER: SCALE: NTS DRK KDB 06/04/24 2294 V-DATUM: NAVD 88 H-DATUM: NAD 83 OF 11 04/21/25 SAN-A PROFILE SANITARY SEWER PROFILE 843/322-0553 843/322-0556 (FAX) CAROLINA ENGINEERING CONSULTANTS, INC. PO BOX 294 BEAUFORT, SC 29901WWW.CAROLINAENGINEERING.COM - 6 - DESCRIPTION PLAN REVISIONS NO. 3 2 1 4 5 - - - - - DATE - - - - - 8 7 - - - - *ANY INFRINGEMENT MAY BE SUBJECT TO LEGAL ACTION. THE DESIGNS AND IDEAS PRESENTED IN THESE DRAWINGS ARE THE PROPERTY OF SAID ENGINEER. THE REPRODUCTION, COPY, OR USE OF THESE PLANS OR THE INFORMATION IS STRICTLY PROHIBITED WITHOUT THE WRITTEN CONSENT OF THE ENGINEER. 11 OF 11 69 MERIDIAN ROAD LADY'S ISLAND BEAUFORT COUNTY, SC PROJECT: DATE: REVISED: DRAWN BY: ENGINEER: SCALE: 1"=30' JPA RGG 04/21/25 05/14/24 2294 V-DATUM: NAVD 88 H-DATUM: NAD 83 04/21/2025 N/F BEAUFORT COUNTY SCHOOL DISTRICT N/F LEE FRAISER N/F SHELDON 123 LLC N/F BEAUFORT COUNTY SCHOOL DISTRICT N/F RICHARD KIRKLAND N/F LARRY KIRKLAND N/F 66 MERIDIAN ROAD LLC N/F 64 MERIDIAN ROAD LLC YOUMANS DRIVE (S-7-266) CAROLYN DRIVE COUNTY OWNED 30' R/W MERIDIAN ROAD (S-36) 66' R/W RUN ENCR LMAN GENERAL NOTES, ENCROACHMENT PLAN 1 OF 1 843/322-0553 843/322-0556 (FAX) CAROLINA ENGINEERING CONSULTANTS, INC. PO BOX 294 BEAUFORT, SC 29901WWW.CAROLINAENGINEERING.COM - 6 - DESCRIPTION PLAN REVISIONS NO. 3 2 1 4 5 - - - - - DATE - - - - - 8 7 - - - - *ANY INFRINGEMENT MAY BE SUBJECT TO LEGAL ACTION. THE DESIGNS AND IDEAS PRESENTED IN THESE DRAWINGS ARE THE PROPERTY OF SAID ENGINEER. THE REPRODUCTION, COPY, OR USE OF THESE PLANS OR THE INFORMATION IS STRICTLY PROHIBITED WITHOUT THE WRITTEN CONSENT OF THE ENGINEER. 69 MERIDIAN ROAD LADY'S ISLAND BEAUFORT COUNTY, SC PROJECT: DATE: REVISED: DRAWN BY: ENGINEER: SCALE: 1"=30' JPA BJS 04/21/25 05/14/24 2294 V-DATUM: NAVD 88 H-DATUM: NAD 83 04/21/2025 REFERENCE PLAN PROPOSED CONDITIONS PRELIMINARY SUBMITTAL PLAN, NOT FOR CONSTRUCTION DRAWING NUMBER DRAWING TITLE DESIGN CONCEPTS, DRAWING, SHEETS, LOGOS, SPECIFICATIONS, DETAILS, WRITTEN MATERIAL SHALL NOT BE USED OR REPRODUCED IN WHOLE OR IN PART IN ANY FORM WITHOUT PRIOR WRITTEN CONSENT OF WJK LTD. © 2023 WJK LTD. THIS SHEET TO SCALE AT: 24"X36" DATE: PROJECT NO.: DRAWN BY: CHECKED BY: APR 30, 2025 24156.01 CK DK REVISIONS: SITE DEVELOPMENT PLANS FOR TOWNHOMES BEAUFORT, SOUTH CAROLINA AT 69 MERIDIAN ROAD L1 c N E W 0 30 60 90 120 15 45 75105 Scale 1 " = 30' YOUMANS DRIVE CAROLYN DRIVE MERIDIAN ROAD BEAUFORT COUNTY SCHOOL DISTRICT EXISTING RESIDENCE PROPERTY LINE 10' B.S.L. PROPERTY LINE 0' - 15' FRONT BUILD TO LINE PROPERTY LINE 0 - 15' FRONT BUILD TO LINE PROPERTY LINE 10' B.S.L. PLANTING PLAN - 01 L2 PRELIMINARY SUBMITTAL PLAN, NOT FOR CONSTRUCTION DRAWING NUMBER DRAWING TITLE DESIGN CONCEPTS, DRAWING, SHEETS, LOGOS, SPECIFICATIONS, DETAILS, WRITTEN MATERIAL SHALL NOT BE USED OR REPRODUCED IN WHOLE OR IN PART IN ANY FORM WITHOUT PRIOR WRITTEN CONSENT OF WJK LTD. © 2023 WJK LTD. THIS SHEET TO SCALE AT: 24"X36" DATE: PROJECT NO.: DRAWN BY: CHECKED BY: APR 30, 2025 24156.01 CK DK REVISIONS: SITE DEVELOPMENT PLANS FOR TOWNHOMES BEAUFORT, SOUTH CAROLINA AT 69 MERIDIAN ROAD PLANT KEY LEGEND c N E W 0 10 20 30 40 5 1525 35 Scale 1 " = 10' PLANTING DETAILS DETAIL DESCRIPTION TREE PLANTING14.1 CALL- OUT 14.2 14.3 PALM TREE PLANTING SHRUB PLANTING 14.4GROUND COVER PLANTING 1/L5 2/L5 3/L5 4/L5 PLANTING REFERENCE NOTES: 1EXISTING TREES TO REMAIN. EXISTING TREES TO BE REMOVED. REFER TO CIVIL ENGINEER PLANS FOR FULL TREE REMOVAL INFORMATION. CONTRACTOR SHALL REPAIR OR REPLACE ANY AND ALL GRASS DAMAGED DURING CONSTRUCTION. MULCH DISTURBED AREAS DUE TO CONSTRUCTION. MULCH RING, TYP. CAREFULLY EXCAVATE SHRUB PITS IN VICINITY OF EXISTING TREES, WITHOUT DISTURBING TREE ROOTS. COORDINATE SHRUB LAYOUT WITH EXISTING UTILITIES. REPORT ANY CONFLICTS TO LANDSCAPE ARCHITECT. FIELD ADJUST SABP PER PROPOSED UTILITIES. PROTECT AREA DRAIN FROM CLOGGING DURING INSTALLATION OF PLANTS AND MULCH. MAINTAIN FUNCTIONALITY AND POSITIVE PITCH TO DRAIN. PROVIDE 2" P.V.C. CONDUIT FOR IRRIGATION TO PLANTERS. COORDINATE IRRIGATION CONTROLLER LOCATION WITH CIVIL ENGINEER (CAROLINA ENGINEERING CONSULTANTS). 2 4 3 5 6 7 8 9 10 11 YOUMANS DRIVE MERIDIAN ROAD EXISTING RESIDENCE PROPERTY LINE 10' B.S.L. PROPERTY LINE 0' - 15' FRONT BUILD TO LINE PROPERTY LINE 0 - 15' FRONT BUILD TO LINE MATCHLINE MATCHLINE MATCHLINE MATCHLINE 17 PODM 3 VIBS 1 LAGN 3 VIBS 1 LAGN 3 VIBS 1 LAGN 3 VIBS 1 LAGN 17 PODM 5 ILEV SOD 1 SABP 1 AZAE 1 SABP 1 AZAE 1 SABP 1 AZAE 1 SABP 1 AZAE 3 MAGL 1 QUEV SOD SOD SOD SOD SOD SOD 1 QUEV 9 MYRC 3 MAGL 3 VIBO 5 MYRC 3 VIBO 1 MAGL 1 SABP 1 AZAE 1 SABP 1 AZAE 1 SABP 1 AZAE 1 SABP 1 AZAE 1 SABP 1 AZAE SOD 1 LAGT 9 VIBS 25 DRYE 3 PODM 1 LAGN 25 DRYE 3 PODM 1 LAGN 25 DRYE 3 PODM 1 LAGN 25 DRYE 3 PODM 1 LAGN 25 DRYE 3 PODM 1 LAGN 1 TYP. 6 TYP. 2 TYP. 3 TYP. 4 TYP. 5TYP. 9TYP. 7 TYP. 8 TYP. 10 TYP. 14.1TYP. 14.2TYP. 14.3TYP. 14.4 TYP. PLANTING PLAN - 02 L3 PRELIMINARY SUBMITTAL PLAN, NOT FOR CONSTRUCTION DRAWING NUMBER DRAWING TITLE DESIGN CONCEPTS, DRAWING, SHEETS, LOGOS, SPECIFICATIONS, DETAILS, WRITTEN MATERIAL SHALL NOT BE USED OR REPRODUCED IN WHOLE OR IN PART IN ANY FORM WITHOUT PRIOR WRITTEN CONSENT OF WJK LTD. © 2023 WJK LTD. THIS SHEET TO SCALE AT: 24"X36" DATE: PROJECT NO.: DRAWN BY: CHECKED BY: APR 30, 2025 24156.01 CK DK REVISIONS: SITE DEVELOPMENT PLANS FOR TOWNHOMES BEAUFORT, SOUTH CAROLINA AT 69 MERIDIAN ROAD YOUMANS DRIVE PROPERTY LINE 10' B.S.L. PROPERTY LINE 0 - 15' FRONT BUILD TO LINE MATCHLINE MATCHLINE MATCHLINE MATCHLINE MATCHLINE MATCHLINE MATCHLINE MATCHLINE PLANT KEY LEGEND c N E W 0 10 20 30 40 5 1525 35 Scale 1 " = 10' PLANTING DETAILS DETAIL DESCRIPTION TREE PLANTING14.1 CALL- OUT 14.2 14.3 PALM TREE PLANTING SHRUB PLANTING 14.4GROUND COVER PLANTING 1/L5 2/L5 3/L5 4/L5 PLANTING REFERENCE NOTES: 1EXISTING TREES TO REMAIN. EXISTING TREES TO BE REMOVED. REFER TO CIVIL ENGINEER PLANS FOR FULL TREE REMOVAL INFORMATION. CONTRACTOR SHALL REPAIR OR REPLACE ANY AND ALL GRASS DAMAGED DURING CONSTRUCTION. MULCH DISTURBED AREAS DUE TO CONSTRUCTION. MULCH RING, TYP. CAREFULLY EXCAVATE SHRUB PITS IN VICINITY OF EXISTING TREES, WITHOUT DISTURBING TREE ROOTS. COORDINATE SHRUB LAYOUT WITH EXISTING UTILITIES. REPORT ANY CONFLICTS TO LANDSCAPE ARCHITECT. FIELD ADJUST SABP PER PROPOSED UTILITIES. PROTECT AREA DRAIN FROM CLOGGING DURING INSTALLATION OF PLANTS AND MULCH. MAINTAIN FUNCTIONALITY AND POSITIVE PITCH TO DRAIN. PROVIDE 2" P.V.C. CONDUIT FOR IRRIGATION TO PLANTERS. COORDINATE IRRIGATION CONTROLLER LOCATION WITH CIVIL ENGINEER (CAROLINA ENGINEERING CONSULTANTS). 2 4 3 5 6 7 8 9 10 11 SOD SOD 3 SERS6 SERS 10 VIBS 3 PODM 1 PHIS 1 SABP 3 PODM 1 PHIS 1 SABP 3 PODM 1 PHIS 1 SABP 3 PODM 1 PHIS 1 SABP 1 LAGT 1 AZAE 1 SABP 1 AZAE 1 SABP 1 AZAE 1 SABP 1 AZAE 2 MAGL 5 ILEV 1 QUEV 1 QUEV 3 VIBO 5 MYRC 3 VIBO 1 QUEV 5 MYRC 1 MAGL 14.1 TYP. 14.2 TYP. 14.3TYP. 1TYP. 6TYP. 2 TYP. 3 TYP. 4 TYP. 5TYP. 7TYP. 8 TYP. 10 TYP. 9 TYP. PLANTING PLAN - 03 L4 PRELIMINARY SUBMITTAL PLAN, NOT FOR CONSTRUCTION DRAWING NUMBER DRAWING TITLE DESIGN CONCEPTS, DRAWING, SHEETS, LOGOS, SPECIFICATIONS, DETAILS, WRITTEN MATERIAL SHALL NOT BE USED OR REPRODUCED IN WHOLE OR IN PART IN ANY FORM WITHOUT PRIOR WRITTEN CONSENT OF WJK LTD. © 2023 WJK LTD. THIS SHEET TO SCALE AT: 24"X36" DATE: PROJECT NO.: DRAWN BY: CHECKED BY: APR 30, 2025 24156.01 CK DK REVISIONS: SITE DEVELOPMENT PLANS FOR TOWNHOMES BEAUFORT, SOUTH CAROLINA AT 69 MERIDIAN ROAD YOUMANS DRIVE CAROLYN DRIVE PROPERTY LINE 10' B.S.L. PROPERTY LINE 0 - 15' FRONT BUILD TO LINE PROPERTY LINE 10' B.S.L. PLANT KEY LEGEND c N E W 0 10 20 30 40 5 1525 35 Scale 1 " = 10' PLANTING DETAILS DETAIL DESCRIPTION TREE PLANTING14.1 CALL- OUT 14.2 14.3 PALM TREE PLANTING SHRUB PLANTING 14.4GROUND COVER PLANTING 1/L5 2/L5 3/L5 4/L5 PLANTING REFERENCE NOTES: 1EXISTING TREES TO BE REMOVED. REFER TO CIVIL ENGINEER PLANS FOR FULL TREE REMOVAL INFORMATION. CONTRACTOR SHALL REPAIR OR REPLACE ANY AND ALL GRASS DAMAGED DURING CONSTRUCTION. MULCH DISTURBED AREAS DUE TO CONSTRUCTION. COORDINATE SHRUB LAYOUT WITH EXISTING UTILITIES. REPORT ANY CONFLICTS TO LANDSCAPE ARCHITECT. FIELD ADJUST SABP PER PROPOSED UTILITIES. PROTECT AREA DRAIN FROM CLOGGING DURING INSTALLATION OF PLANTS AND MULCH. MAINTAIN FUNCTIONALITY AND POSITIVE PITCH TO DRAIN. PROVIDE 2" P.V.C. CONDUIT FOR IRRIGATION TO PLANTERS. COORDINATE IRRIGATION CONTROLLER LOCATION WITH CIVIL ENGINEER (CAROLINA ENGINEERING CONSULTANTS). 2 4 3 5 6 7 8 3 PODM 1 PHIS 1 SABP 1 SABP 1 AZAE 3 PODM 1 PHIS 1 SABP 1 AZAE 1 SABP 1 QUEV 1 AZAE 1 SABP 1 AZAE 1 SABP 1 AZAE 1 SABP 1 AZAE 1 SABP 1 AZAE 1 SABP 1 AZAE 3 PODM 1 SABP 3 PODM 1 SABP 3 PODM 1 SABP 3 PODM 1 SABP 3 PODM 1 SABP 3 PODM 1 SABP 4 VIBS 3 MAGL 1 VIBS 2 MAGL 5 MYRC 3 VIBO 3 MAGL 3 VIBO 5 MYRC 3 VIBO 3 VIBO SOD 1 QUEV 14.1 TYP. 14.3 TYP. 14.2 TYP. 1TYP. 2 TYP. 3TYP. 4TYP. 5 TYP. 7 TYP. 6 TYP. MATCHLINE MATCHLINE MATCHLINE MATCHLINE PLANT SCHEDULE AND DETAILS L5 PRELIMINARY SUBMITTAL PLAN, NOT FOR CONSTRUCTION DRAWING NUMBER DRAWING TITLE DESIGN CONCEPTS, DRAWING, SHEETS, LOGOS, SPECIFICATIONS, DETAILS, WRITTEN MATERIAL SHALL NOT BE USED OR REPRODUCED IN WHOLE OR IN PART IN ANY FORM WITHOUT PRIOR WRITTEN CONSENT OF WJK LTD. © 2023 WJK LTD. THIS SHEET TO SCALE AT: 24"X36" DATE: PROJECT NO.: DRAWN BY: CHECKED BY: APR 30, 2025 24156.01 CK DK REVISIONS: SITE DEVELOPMENT PLANS FOR TOWNHOMES BEAUFORT, SOUTH CAROLINA AT 69 MERIDIAN ROAD 1L5TREE PLANTING SCALE: N.T.S.2L5PALM TREE PLANTING SCALE: N.T.S. 3L5SHRUB PLANTING SCALE: N.T.S.4L5GROUND COVER PLANTING SCALE: N.T.S.5L5TREE STAKING SCALE: N.T.S. PLANT SCHEDULE: BLACK RUBBER HOSE 120° 120° 120° PLAN DOUBLE STRAND 12 GAUGE WIRE PROTECT TREE TRUNK WITH BLACK RUBBER HOSE OR APPROVED EQUAL DOUBLE STRAND 12 GAUGE WIRE WITH GALVANIZED TURNBUCKLE OR APPROVED EQUAL. MARK AS HAZARD IN LOCATION WITH HIGH PEDESTRIAN TRAFFIC 3" MINIMUM MULCH DEPTH, REFER TO PLANT SCHEDULE FOR TYPE SOIL BERM TO HOLD WATER TREE 2"X4" STAKES (36" LONG) BURIED BELOW FINISH GRADE - ENSURE STAKES ARE MARKED TO SIGNIFY HAZARD IN LOCATIONS WITH HIGH PEDESTRIAN TRAFFIC FINISH GRADE B&B OR CONTAINERIZED (REFER TO PLANT SCHEDULE) SCARIFY SIDES OF HOLE TO 4" DEPTH MINIMUM AMENDED PLANTING SOIL AS NEEDED PER SOIL ANALYSIS COMPACT PLANTING SOIL BENEATH ROOTBALL NOTES: 1. TREE STAKING OPTIONAL, HOWEVER, LANDSCAPE CONTRACTOR RESPONSIBLE FOR MAINTAINING TREES IN AN UPRIGHT (90 DEGREE/ PERPENDICULAR) POSITION FOR 1 YEAR AFTER PLANTING IS COMPLETE OR UNTIL TREE ROOT SYSTEM IS FULLY ESTABLISHED AND STURDY. FINAL TREE STAKING DETAILS AND PLACEMENT TO BE APPROVED BY OWNER'S REPRESENTATIVE. 2. CONTRACTOR SHALL ASSURE PERCOLATION OF ALL PLANTING PITS PRIOR TO INSTALLATION. 3. IN SEMI-IMPERVIOUS SOIL CONDITIONS, ROOTBALL ELEVATION SHALL BE 2" ABOVE FINISH GRADE. COORDINATE WITH OWNER'S REPRESENTATIVE PRIOR TO SETTING ROOTBALL ELEVATIONS. 12" TYP. 12" MIN. DOUBLE SIZE OF ROOTBALL, TYP. CLEAR TRUNK, REFER TO PLANT SCHEDULE COMPACTED SUBGRADE AMENDED PLANTING SOIL AS NEEDED PER SOIL ANALYSIS 3" MINIMUM MULCH DEPTH, REFER TO PLANT SCHEDULE FOR TYPE FINISH GRADE SOIL BERM TO HOLD WATER MAINTAIN TREE IN A PLUMB UPRIGHT POSITION TRUNK OF PALMETTOS SHALL BE NEARLY UNIFORM IN SIZE OVER ENTIRE HEIGHT AND SHALL BE FREE OF OLD FROND STUBS, FIRE BLACK AND OTHER DAMAGE REFOLIATED PALMETTO NOTES: 1. FINAL TREE STAKING DETAILS AND PLACEMENT TO BE APPROVED BY OWNER OR OWNER'S REPRESENTATIVE, 2. CONTRACTOR SHALL ASSURE PERCOLATION OF ALL PLANTING PITS PRIOR TO INSTALLATION. 3. SABAL PALMETTOS SHALL BE REFOLIATED, PROTECT CABBAGE HEAD FROM DAMAGE. NOTES: 1. WHEN GROUNDCOVERS AND SHRUBS ARE USED IS MASSES, ENTIRE BED TO BE EXCAVATED TO RECEIVE PLANTING SOIL AND PLANT MATERIAL. 2. CONTRACTOR SHALL ASSURE PERCOLATION OF ALL PLANTING PITS PRIOR TO INSTALLATION. 3. IN SEMI-IMPERVIOUS SOIL CONDITIONS, ROOTBALL ELEVATION SHALL BE ±2" ABOVE FINISH GRADE. COORDINATE WITH OWNER'S REPRESENTATIVE PRIOR TO SETTING ROOTBALL ELEVATIONS. 4" TYP. DOUBLE SIZE OF ROOTBALL, TYP. AMENDED PLANTING SOIL AS NEEDED PER SOIL ANALYSIS B&B OR CONTAINERIZED (SEE PLANTING SCHEDULE, THIS SHEET) FINISH GRADE SOIL BERM TO HOLD WATER 3" MINIMUM MULCH DEPTH, REFER TO PLANT SCHEDULE FOR TYPE -- - SPECIFIED O.C. SPACING NOTE: 1. EXCAVATE ENTIRE BED SPECIFIED FOR GROUNDCOVER PLANTING TO A DEPTH OF 12" TYPICAL EDGE OF PLANT BED 1/2 OF SPECIFIED O.C. SPACING SPECIFIED O.C. SPACING ATYPICAL SPACING IN CURVILINEAR PLANT BEDS. OUTSIDE ROW TO FOLLOW CURVE AS SHOWN ON PLAN ±5' DIA. 3" MINIMUM MULCH DEPTH, REFER TO PLANT SCHEDULE FOR TYPE SMOOTH CONTINUOUSLY CUT EDGE TYPICAL TREE TREE STAKE NOTES: 1. APPLY MULCH IN A ±5' DIAMETER WHERE PROPOSED TREE PLANTINGS OCCUR IN SOD OR SEEDED AREAS. BFT-22385 AT1.dwg 24X36 9/26/2022 15:53:01 BFT-22385 AT1.dwg 24X36 9/26/2022 15:53:01 HARBOR ROW AT M E R I D I A N ARCHITECTURE 1328 BLANDING STREET COLUMBIA SC 29201 803.699.0844 DAVISARCHITECTURE.COM FOR ARCHITECTURAL REVIEW ARCHITECTURE 1328 BLANDING STREET COLUMBIA SC 29201 803.699.0844 DAVISARCHITECTURE.COM FOR ARCHITECTURAL REVIEW ARCHITECTURE 1328 BLANDING STREET COLUMBIA SC 29201 803.699.0844 DAVISARCHITECTURE.COM FOR ARCHITECTURAL REVIEW ARCHITECTURE 1328 BLANDING STREET COLUMBIA SC 29201 803.699.0844 DAVISARCHITECTURE.COM FOR ARCHITECTURAL REVIEW ARCHITECTURE 1328 BLANDING STREET COLUMBIA SC 29201 803.699.0844 DAVISARCHITECTURE.COM FOR ARCHITECTURAL REVIEW ARCHITECTURE 1328 BLANDING STREET COLUMBIA SC 29201 803.699.0844 DAVISARCHITECTURE.COM FOR ARCHITECTURAL REVIEW ARCHITECTURE 1328 BLANDING STREET COLUMBIA SC 29201 803.699.0844 DAVISARCHITECTURE.COM FOR ARCHITECTURAL REVIEW ARCHITECTURE 1328 BLANDING STREET COLUMBIA SC 29201 803.699.0844 DAVISARCHITECTURE.COM FOR ARCHITECTURAL REVIEW ARCHITECTURE 1328 BLANDING STREET COLUMBIA SC 29201 803.699.0844 DAVISARCHITECTURE.COM FOR ARCHITECTURAL REVIEW ARCHITECTURE 1328 BLANDING STREET COLUMBIA SC 29201 803.699.0844 DAVISARCHITECTURE.COM FOR ARCHITECTURAL REVIEW ARCHITECTURE 1328 BLANDING STREET COLUMBIA SC 29201 803.699.0844 DAVISARCHITECTURE.COM FOR ARCHITECTURAL REVIEW ARCHITECTURE 1328 BLANDING STREET COLUMBIA SC 29201 803.699.0844 DAVISARCHITECTURE.COM FOR ARCHITECTURAL REVIEW STUDY/ BEDROOM 13'-0" x 11'-0" BATH GARAGE 15'-0" x 21'-6" HALL COVERED FORECOURT PATIO STUDY/ BEDROOM 13'-0" x 11'-0" BATH GARAGE 15'-0" x 21'-6" HALL COVERED FORECOURT PATIO ARCHITECTURE 1328 BLANDING STREET COLUMBIA SC 29201 803.699.0844 DAVISARCHITECTURE.COM FOR ARCHITECTURAL REVIEW LIVING/ DINING 13'-0" x 21'-0" KITCHEN 13'-8" x 15'-9" LANDING COVERED PORCH FRONT PORCH PDR LIVING/ DINING 13'-0" x 21'-0" KITCHEN 13'-8" x 15'-9" LANDING COVERED PORCH FRONT PORCH PDR ARCHITECTURE 1328 BLANDING STREET COLUMBIA SC 29201 803.699.0844 DAVISARCHITECTURE.COM FOR ARCHITECTURAL REVIEW BEDROOM 12'-4" x 15'-9" WC BATH SHOWER LAU HALL BATH WIC LIN BEDROOM 12'-4" x 14'-8" BEDROOM 12'-4" x 15'-9" WC BATH SHOWER LAU HALL BATH WIC LIN BEDROOM 12'-4" x 14'-8" ARCHITECTURE 1328 BLANDING STREET COLUMBIA SC 29201 803.699.0844 DAVISARCHITECTURE.COM FOR ARCHITECTURAL REVIEW ARCHITECTURE 1328 BLANDING STREET COLUMBIA SC 29201 803.699.0844 DAVISARCHITECTURE.COM FOR ARCHITECTURAL REVIEW ARCHITECTURE 1328 BLANDING STREET COLUMBIA SC 29201 803.699.0844 DAVISARCHITECTURE.COM FOR ARCHITECTURAL REVIEW ARCHITECTURE 1328 BLANDING STREET COLUMBIA SC 29201 803.699.0844 DAVISARCHITECTURE.COM FOR ARCHITECTURAL REVIEW ARCHITECTURE 1328 BLANDING STREET COLUMBIA SC 29201 803.699.0844 DAVISARCHITECTURE.COM FOR ARCHITECTURAL REVIEW STUDY/ BEDROOM 13'-0" x 11'-0" BATH GARAGE 15'-0" x 21'-6" HALL COVERED FORECOURT PATIO LIVING/ DINING 13'-0" x 21'-0" KITCHEN 13'-8" x 15'-9" LANDING COVERED PORCH FRONT PORCH PDR BEDROOM 12'-4" x 15'-9" WC BATH SHOWER LAU HALL BATH WIC LIN BEDROOM 12'-4" x 14'-8" ARCHITECTURE 1328 BLANDING STREET COLUMBIA SC 29201 803.699.0844 DAVISARCHITECTURE.COM FOR ARCHITECTURAL REVIEW COVERED PORCH ARCHITECTURE 1328 BLANDING STREET COLUMBIA SC 29201 803.699.0844 DAVISARCHITECTURE.COM FOR ARCHITECTURAL REVIEW ARCHITECTURE 1328 BLANDING STREET COLUMBIA SC 29201 803.699.0844 DAVISARCHITECTURE.COM FOR ARCHITECTURAL REVIEW ARCHITECTURE 1328 BLANDING STREET COLUMBIA SC 29201 803.699.0844 DAVISARCHITECTURE.COM FOR ARCHITECTURAL REVIEW ARCHITECTURE 1328 BLANDING STREET COLUMBIA SC 29201 803.699.0844 DAVISARCHITECTURE.COM FOR ARCHITECTURAL REVIEW ARCHITECTURE 1328 BLANDING STREET COLUMBIA SC 29201 803.699.0844 DAVISARCHITECTURE.COM STUDY/ BEDROOM 13'-0" x 11'-0" BATH GARAGE 15'-0" x 21'-6" HALL STUDY/ BEDROOM 13'-0" x 11'-0" BATH GARAGE 15'-0" x 21'-6" HALL FOR ARCHITECTURAL REVIEW ARCHITECTURE 1328 BLANDING STREET COLUMBIA SC 29201 803.699.0844 DAVISARCHITECTURE.COM LIVING/ DINING 13'-0" x 21'-0" KITCHEN 13'-8" x 15'-9" LANDING PDR LIVING/ DINING 13'-0" x 21'-0" KITCHEN 13'-8" x 15'-9" LANDING PDR JULIET BALCONY FOR ARCHITECTURAL REVIEW JULIET BALCONY JULIET BALCONY JULIET BALCONY ARCHITECTURE 1328 BLANDING STREET COLUMBIA SC 29201 803.699.0844 DAVISARCHITECTURE.COM BEDROOM 12'-4" x 15'-9" WC BATH SHOWER LAU HALL BATH WIC LIN BEDROOM 12'-4" x 14'-8" BEDROOM 12'-4" x 15'-9" WC BATH SHOWER LAU HALL BATH WIC LIN BEDROOM 12'-4" x 14'-8" FOR ARCHITECTURAL REVIEW ARCHITECTURE 1328 BLANDING STREET COLUMBIA SC 29201 803.699.0844 DAVISARCHITECTURE.COM FOR ARCHITECTURAL REVIEW ARCHITECTURE 1328 BLANDING STREET COLUMBIA SC 29201 803.699.0844 DAVISARCHITECTURE.COM FOR ARCHITECTURAL REVIEW ARCHITECTURE 1328 BLANDING STREET COLUMBIA SC 29201 803.699.0844 DAVISARCHITECTURE.COM FOR ARCHITECTURAL REVIEW ARCHITECTURE 1328 BLANDING STREET COLUMBIA SC 29201 803.699.0844 DAVISARCHITECTURE.COM FOR ARCHITECTURAL REVIEW STUDY/ BEDROOM 13'-0" x 11'-0" BATH GARAGE 15'-0" x 21'-6" HALL LIVING/ DINING 13'-0" x 21'-0" KITCHEN 13'-8" x 15'-9" LANDING PDR JULIET BALCONY BEDROOM 12'-4" x 15'-9" WC BATH SHOWER LAU HALL BATH WIC LIN BEDROOM 12'-4" x 14'-8" ARCHITECTURE 1328 BLANDING STREET COLUMBIA SC 29201 803.699.0844 DAVISARCHITECTURE.COM FOR ARCHITECTURAL REVIEW JULIET BALCONY ARCHITECTURE 1328 BLANDING STREET COLUMBIA SC 29201 803.699.0844 DAVISARCHITECTURE.COM FOR ARCHITECTURAL REVIEW ARCHITECTURE 1328 BLANDING STREET COLUMBIA SC 29201 803.699.0844 DAVISARCHITECTURE.COM FOR ARCHITECTURAL REVIEW ARCHITECTURE 1328 BLANDING STREET COLUMBIA SC 29201 803.699.0844 DAVISARCHITECTURE.COM FOR ARCHITECTURAL REVIEW ARCHITECTURE 1328 BLANDING STREET COLUMBIA SC 29201 803.699.0844 DAVISARCHITECTURE.COM FOR ARCHITECTURAL REVIEW ARCHITECTURE 1328 BLANDING STREET COLUMBIA SC 29201 803.699.0844 DAVISARCHITECTURE.COM FOR ARCHITECTURAL REVIEW STUDY/ BEDROOM 13'-0" x 11'-0" BATH GARAGE 15'-0" x 21'-6" HALL STUDY/ BEDROOM 13'-0" x 11'-0" BATH GARAGE 15'-0" x 21'-6" HALL ARCHITECTURE 1328 BLANDING STREET COLUMBIA SC 29201 803.699.0844 DAVISARCHITECTURE.COM FOR ARCHITECTURAL REVIEW LIVING/ DINING 13'-0" x 21'-0" KITCHEN 13'-8" x 15'-9" LANDING PDR LIVING/ DINING 13'-0" x 21'-0" KITCHEN 13'-8" x 15'-9" LANDING PDR JULIET BALCONY JULIET BALCONY JULIET BALCONY ARCHITECTURE 1328 BLANDING STREET COLUMBIA SC 29201 803.699.0844 DAVISARCHITECTURE.COM FOR ARCHITECTURAL REVIEW BEDROOM 12'-4" x 15'-9" WC BATH SHOWER LAU HALL BATH WIC LIN BEDROOM 12'-4" x 14'-8" BEDROOM 12'-4" x 15'-9" WC BATH SHOWER LAU HALL BATH WIC LIN BEDROOM 12'-4" x 14'-8" ARCHITECTURE 1328 BLANDING STREET COLUMBIA SC 29201 803.699.0844 DAVISARCHITECTURE.COM FOR ARCHITECTURAL REVIEW ARCHITECTURE 1328 BLANDING STREET COLUMBIA SC 29201 803.699.0844 DAVISARCHITECTURE.COM FOR ARCHITECTURAL REVIEW ARCHITECTURE 1328 BLANDING STREET COLUMBIA SC 29201 803.699.0844 DAVISARCHITECTURE.COM FOR ARCHITECTURAL REVIEW ARCHITECTURE 1328 BLANDING STREET COLUMBIA SC 29201 803.699.0844 DAVISARCHITECTURE.COM FOR ARCHITECTURAL REVIEW STUDY/ BEDROOM 13'-0" x 11'-0" BATH GARAGE 15'-0" x 21'-6" HALL LIVING/ DINING 13'-0" x 21'-0" KITCHEN 13'-8" x 15'-9" LANDING PDR JULIET BALCONY BEDROOM 12'-4" x 15'-9" WC BATH SHOWER LAU HALL BATH WIC LIN BEDROOM 12'-4" x 14'-8" ARCHITECTURE 1328 BLANDING STREET COLUMBIA SC 29201 803.699.0844 DAVISARCHITECTURE.COM FOR ARCHITECTURAL REVIEW JULIET BALCONY ARCHITECTURE 1328 BLANDING STREET COLUMBIA SC 29201 803.699.0844 DAVISARCHITECTURE.COM FOR ARCHITECTURAL REVIEW ARCHITECTURE 1328 BLANDING STREET COLUMBIA SC 29201 803.699.0844 DAVISARCHITECTURE.COM FOR ARCHITECTURAL REVIEW ARCHITECTURE 1328 BLANDING STREET COLUMBIA SC 29201 803.699.0844 DAVISARCHITECTURE.COM FOR ARCHITECTURAL REVIEW HARBOR ROW A R R I V A L HARBOR ROW 1 ST L E V E L P L A N G A R A G E S T U D Y C O V E R E D P A T I O H A L LE L E V . UP UP HARBOR ROW 2 N D F L O O R P L A N E L E V . K I T C H E N L I V I N G R M E N T R YUP DN DN UP C O V E R E D P O R C H D I N I N G R M HARBOR ROW 3 RD F L O O R P L A N B E D R O O M 2 B E D R O O M 1 DN E L E V L A U N D R Y HARBOR ROW 1 ST F L O O R V I E W STUDY/BEDROOM13'-0" x 11'-0" BATH GARAGE15'-0" x 21'-6" HALL COVEREDFORECOURT PATIO STUDY/BEDROOM13'-0" x 11'-0" BATH GARAGE15'-0" x 21'-6" HALL COVEREDFORECOURT PATIO STUDY/BEDROOM13'-0" x 11'-0" BATH GARAGE15'-0" x 21'-6" HALL STUDY/BEDROOM13'-0" x 11'-0" BATH GARAGE15'-0" x 21'-6" HALL OUTLINE OF PORCH ABOVE OUTLINE OF PORCH ABOVE OUTLINE OF PORCH ABOVE STUDY/BEDROOM13'-0" x 11'-0" BATH GARAGE15'-0" x 21'-6" HALL STUDY/BEDROOM13'-0" x 11'-0" BATH GARAGE15'-0" x 21'-6" HALL OUTLINE OF PORCH ABOVE OUTLINE OF PORCH ABOVE OUTLINE OF PORCH ABOVE OUTLINE OF PORCH ABOVE STUDY/BEDROOM13'-0" x 11'-0" BATH GARAGE15'-0" x 21'-6" HALL STUDY/BEDROOM13'-0" x 11'-0" BATH GARAGE15'-0" x 21'-6" HALL OUTLINE OF PORCH ABOVE OUTLINE OF PORCH ABOVE OUTLINE OF PORCH ABOVE OUTLINE OF PORCH ABOVE N/F BEAUFORT COUNTY SCHOOL DISTRICT N/F LEE FRAISER N/F SHELDON 123 LLC N/F BEAUFORT COUNTY SCHOOL DISTRICT N/F RICHARD KIRKLAND N/F LARRY KIRKLAND N/F 66 MERIDIAN ROAD LLC N/F 64 MERIDIAN ROAD LLC YOUMANS DRIVE (S-7-266) SCDOT OWNED MERIDIAN ROAD (S-36) SCDOT OWNED CAROLYN DRIVE 30' R/W (LOCAL) 843/322-0553 843/322-0556 (FAX) CAROLINA ENGINEERING CONSULTANTS, INC. PO BOX 294 BEAUFORT, SC 29901 LOT COVERAGE EXHIBIT 69 MERIDIAN RD LADY'S ISLAND BEAUFORT COUNTY, SC WWW.CAROLINAENGINEERING.COM - 6 - DESCRIPTION PLAN REVISIONS NO. 3 2 1 4 5 - - - - - DATE - - - - - 8 7 - - - - *ANY INFRINGEMENT MAY BE SUBJECT TO LEGAL ACTION. THE DESIGNS AND IDEAS PRESENTED IN THESE DRAWINGS ARE THE PROPERTY OF SAID ENGINEER. THE REPRODUCTION, COPY, OR USE OF THESE PLANS OR THE INFORMATION IS STRICTLY PROHIBITED WITHOUT THE WRITTEN CONSENT OF THE ENGINEER. RUN SITE LMAN 1 OF 1 10/12/26REVISED: 2294 11/02/22 KDB JPA 1"=30' ENGINEER: SCALE: DATE: DRAWN BY: PROJECT: TOTAL AREA ROOF COVERAGE % IMPERVIOUS COVERAGE % 1,734 SF 62% 81% 1,683 SF 62% 79% 1,683 SF 62% 79% 1,696 SF 62% 79% 1,604 SF 68% 88% 1,617 SF 57% 78% 1,612 SF 57% 79% 1,608 SF 58% 79% 1,619 SF 68% 87% 1,520 SF 67% 87% 1,538 SF 65% 87% 1,538 SF 65% 87% 1,550 SF 66% 87% 1,521 SF 67% 87% 1,538 SF 65% 87% 1,549 SF 66% 87% 1,520 SF 67% 87% 1,538 SF 65% 87% 1,538 SF 65% 87% 1,550 SF 66% 87% LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 LOT 7 LOT 8 LOT 9 LOT 10 LOT 11 LOT 12 LOT 13 LOT 14 LOT 15 LOT 16 LOT 17 LOT 18 LOT 19 LOT 20 authorized. Any future work for this project not shown on the stamped, approved plans will require that you submit another site plan for review and approval. All major modifications require review and approval by the Department. Minor modifications to the approved SWPPP may be made by the SWPPP preparer and do not require review and approval by the Department; these changes should be signed and dated by the SWPPP preparer. If you have a question about whether a modification is major or minor, contact the Coastal Stormwater Permitting Section at (843) 953-0200. A copy of the stamped, approved SWPPP (including a copy of the CGP, contractor certifications, inspection records, rainfall data, etc.), NOI, and CGP coverage letter from SCDES must be retained and available at the construction site (or accessible within 30 minutes during normal business hours) from the date of commencement of construction activities to the date of final stabilization. If an on-site location is unavailable to store the SWPPP when no personnel are present, notice of the plan’s location must be posted near the main entrance at the construction site. All contractors who will conduct land-disturbing activities at the site must complete a Contractor Certification Form. You are also responsible for listing all contractors in the SWPPP and for holding a pre-construction conference with each contractor before they can conduct land-disturbing activity at the site. The Department may conduct periodic inspections of your site. Any violations found during these inspections may result in enforcement action. This NPDES coverage should be terminated by the permittee when the conditions listed in Section 5.1 of the CGP have been met. You must submit a Notice of Termination (NOT) to cancel your NPDES coverage under the CGP. Please see section 5.1 of the CGP for additional information required to be submitted with the NOT. You are responsible for obtaining any other federal, state, or local permit that may be required for this project. In particular, any permits through the U.S. Army Corps of Engineers for the placement of fill material in Waters of the United States. Please note we have not sent a copy of this letter to any county or city building official. You must send a copy of this letter to these agencies, if necessary. If material excavated during construction activities leaves the site, a mine operating permit may be needed. You are responsible for contacting the Mining and Reclamation Section to determine if a mining permit is required for the site. The Mining and Reclamation Section can be reached at (803)898-1362 or via e-mail at AskMines@des.sc.gov. S.C. Code Ann. § 48-6-30(D)(2) provides, “Within thirty calendar days after the mailing of a decision [pursuant to S.C. Code Ann.§ 48-6-30(D)(1)], an applicant, permittee, licensee, certificate holder, or affected person desiring to contest the department decision may request a contested case hearing before the Administrative Law Court, in accordance with the Administrative Procedures Act.” If you have any questions or cannot access the referenced websites, please call me at (843) 953-0238. Sincerely, George M. Cox, Coastal Stormwater Permitting Section ec: Jeffrey Ackerman, Carolina Engineering Consulting Inc. Jackson Warren, Lowcountry EA Beaufort October 19, 2026 Ms. Heather Stephenson City of Beaufort 1911 Boundary Street Beaufort, SC 29902 R e: 69 Meridian Road Beaufort County, SC Job #2294 Dear Heather: We are resubmitting for Sketch Plan and Preliminary Plat approval. See the following for responses to comments provided via email on August 3, 2026. Bruce Skipper Building Official: 1. It appears that this project will be a condominium type project. The lots do not appear to be deeded lots. I didn’t see any utility easements. Correct me if I am wrong. With that assumption, I will need to know where the electric meter and electric service disconnect be located on each unit. All units will be on individual lots. CC&R documents will be recorded with the plat granting utility rights across HOA common space and individually owned lots. Electric meters are planned on the garage side of every unit. 2. I noted side walks were located on the site plan. Will they tie into existing sidewalks or just abruptly stop to be continued when the next project continues. There are currently no adjacent sidewalks to connect to. SCDOT has denied sidewalks within the R/W on this project, and we had to place the sidewalks on private property. Planning: 1) In accordance with our just revised Chapter 4 provisions for Rowhomes/Townhouses in Sec. 4.5.6, the applicant will have to show for required Housing Model Diversity (i.e., at least two distinctly different building designs, which must reflect traditional Beaufort Lowcountry architectural elements) *; We have designed a unified theme for the project, but have varied specific detailing for elements such as porches, balconies, and stairs. We have also introduced subtle variations of paint colors at each unit. 2) Will there be sidewalks (currently missing) built along the specific street frontage of Meridian Road / Youmans Drive for pedestrian accessibility, maybe even creating pedestrian pathway connections to nearby Beaufort High School? SCDOT has denied sidewalks within the R/W on Yeomans and Meridian. We have placed sidewalks on private property and extended as far as able. 3) What will on-site Stormwater Management (BMPs) look like? Could the two main green areas at the main entrance be designed to have raingardens installed? Also, will the pavement be pervious or impervious? Former would be preferred for less superficial stormwater runoff volume and natural percolation. On site stormwater management is made up of pervious paving and underground stormwater retention chambers to meet City of Beaufort and SCDES stormwater regulations. No additional rain gardens will be needed in the green areas and the green areas can be utilized as passive open space. 4) Positive note: the landscaping seems to include existing specimen/landmark (Live Oak) trees We are working around the existing oak trees to have a grand entrance to the development. 5) With Beaufort High School’s Athletic Fields being located directly across the proposed townhomes on Youman’s Drive, is there any additional landscaping/buffering planned in conjunction with the School District to alleviate any potential noise disruptions. Also, to better screen the two uses from each other, since they are located very close to each other. We are in discussions with Beaufort High baseball coach to add additional safety net to keep the baseballs within playing field. No additional buffering other than the proposed planting is proposed for the development. 6) Both Carolyn Drive as a secondary access road as well as Youman’s Drive are very narrow streets which could be impacted by any additional neighborhood traffic coming from this proposed development. It may be warranted looking into the option of providing a separate turn lane from Youman’s Drive and also to widen that section of Carolyn Drive affected by the new development. We have received approval from the SCDOT on the proposed access as designed. Both Youmans and Carolyn are a minimum of 20’ pavement with and adequate to serve the development. SCDOT encroachment permit is provided. Architecture Comments: Meadors (see comments from Nov ember answered in Green, and additional comments from this request below): 1. Applicant is showing a covered pavilion visible from the site’s ingress/egress point on renderings, but this is not shown on any plans. Applicant to clarify. Applicant confirmed there is no pavilion in the scope. 2. T he rendered landscape plan shows a different front access and entry courtyard configuration. Units 1-4, 5-9, and 10-21 each show a different layout. Site plan seems to match 2D drawings. 3. Applicant to provide side and rear elevation drawings. Applicant to provide 2D elevation drawings with dimensions at a future meeting. These have been provided. 4. A pplicant has not included any sections, typical window head/sill/jamb details, or typical roof eave details. Staff would like to see a section through the covered porch as well as the stoop. These have been provided. 5. T here are two rows of 6 townhomes along Youmans Drive. Staff has concerns that a grouping of 6 townhomes will begin to appear long and monotonous. Staff is supportive of the 4-townhouse layout and recommends the applicant convert the 2 6-townhouse configuration to a 3 4- townhouse layout. Applicant stated that they can’t split these further without sacrificing several landmark and specimen trees. The 6 unit buildings have been removed and replaced w ith 2 four unit and one 3 unit buildings. 6. Applicant to identify the locations for any mechanical equipment and hide or screen them from v iew per Section 4.6.1.F.2. Service yards are shown in the renderings at the rear , but they are not shown in plan (landscape plans show an Azalea shrub in this location. Please coordinate). Screen details need to be provided. The Landscape plan has been revised accordingly. 7. Applicant to clarify if the sidewalk layouts on the renderings match what is shown on the r enderings. Renderings were provided that show the walkways. Note : renderings show that building 1 has a porch, but the building 1 elevations show awning roof and not a porch. Renderings and architectural elevations have been coo rdinated and updated. 8. Applicant to provide paint colors and material cutshe ets at a future submission. This includes windows, doors, roofing, cladding, exterior lighting, etc. All relevant selections should be circled on the cutsheets. No cutsheets provided yet. Cutsheets for paint colors and all exterior materials will be provided at a future submission. 9. Applicant to demonstrate compliance with all requirements as listed in Section 2.4.1. A lot coverage exhibit is provided showing compliance . 10. Staff recommends converting the shed porch roofs to low-sloped hip roofs to make the roof less v isible from street view. This was not done. The gable entries stoop roofs may be a little high relative to the door, but their placement vertically in the composition is fine. Stoop roofs have been redesigned. 11. Staff currently feels as though there are two private frontage types (the porch and the stoop), an d understands the programmatic need to place them at two different levels. Staff recommends the applicant study the front façade to reduce the multiple frontage types. They elim inated the sidewalks that led to the patio areas to clarify this condition. This was also updated in the renderings. 12. Staff recommends the applicant remove the transom win dow at the top of the staircase, as transoms like this are atypical in Beaufort. The 2 over 2 window in the staircase should align with the others in the bedrooms. Staff recommends the applicant study the use of a trimboard or other elements to break up the siding on this plane. It looks like they did not do this for Bu ilding 1. They eliminated it from buildings 2, 3, and 4 but now they split the fenestration into two windows stacked. 7.17.2026 - Additional 69 Meridian Comments – T4-N 1. G eneral: a. The townhomes measure almost 50’ tall from ground to top of ridge, which seems tall. The primary gable forms seems especially prominent and visible on the front façade. Staff recommends reducing the slope of the main roof. Slope of primary roof has been reduced to 8:12. Current height of ridge is 46’. b. Staff has concerns that the windowsill detail does not show a traditional projecting sill, an d the applied 1x4 trim piece at the base of the window does not constitute a true projecting sill piece, and will not have adequate shadow lines. Windows will have true sills. A projecting sill and 1x4 trim are noted at the window sections. c. Staff is not supportive of the projecting brick sill and veneer that extends several inches b eyond the siding wall plane. Staff recommends the applicant consider thin brick or stucco to keep the keep the wall planes in line with one another. Application of brick veneer at ground floor serves as a base at the building. The dimensional break in the wall plane reinforces this effect, lending a weight to the base. d. Staff has concerns about the “bulkiness” of the stoop roof detail. Staff recommends s implifying the stoop roof and consider slightly lowering it to better relate to the door. Stoop roof has been redesigned. e. Many of the renderings that show the rear/garage view, indicate a lap siding cladding in t he pedestrian door alcove/recess and brick veneer around the garage doors. Those alcoves/recesses should also be brick veneer for consistent architectural language around the building base. Floor plans at grade level shall be revised to reflect the brick veneer cladding into these alcoves/recesses for all buildings. Application of the brick veneer would reduce the width of the entry alcove by 10”. Use of siding at the entry alcoves also lightens the feel of the entry for the residents. f. Staff recommends the applicant provide a variety of color schemes to help differentiate t hese units from a single large mass into individual units. Applying subtle color schemes to each unit helps to emphasize their smaller scale compared to the structure as a whole. Refer to the example image in Section 4.5.6-Rowhome of the Beaufort Code. Color scheme has been changed. 2. B uilding 1: a. Staff recommends slightly shifting the column of windows on the left elevation (closer to the front façade) so that they are equally mirrored under the gable roof (see sketch). Windows have been placed as near to being equally mirrored as the floor plan will allow. b. The right elevation does not appear to have any rhythm in its openings. This façade s hould be restudied. Elevation has been modified to align windows as possible. c. The gable return on the left/right facades (closer to the front façade) appears incorrect an d lacks an overhang, like the return on the other side of the gable. Elevations have been modified. d. Staff is not supportive of the blank areas of wall between the gables on the rear façade. Staff recommends adding windows in these areas – the interior configuration may need to be restudied. Plans cannot be reasonably reconfigured. e. Staff recommends centering the rear ground floor pedestrian door within the bay. Door is centered on the entry hall. f. Staff is not supportive of the small window next to the garage doors – these should be m ade larger. Window has been modified. g. The corner shed roof on the front façade appears too close to the edge of the building. T his should be pushed at least 6” in from the edge of the building. The end unit’s windows, doors, and shed roof also do not appear centered within the bay. Shed roof has been modified. h. The bays with triple-ganged windows do not have interior cornerboards. Large interior corner boards are not in keeping with traditional siding details. i. Renderings show Building 1 with porches and so does landscape plans. The 2d drawings fo r building 1 shows awnings. These need to be coordinated. Drawings have been coordinated. 3. Building 2: a. I n building 2, they mix the porch front type and balcony type. Staff does not support the mix of both frontage types on one row of units, when there is already the stoop frontage type on each unit. Staff recommends the applicants pick one for each row (i.e. one row of units has balconies, another row has porches, etc.). Multiple frontage types have been designed with the intent to satisfy the request for Housing Model Diversity. b. The applicant shall provide fenestration to the left and right elevations as they are c urrently blank walls, which would match the design of the left and right elevations in Building 1. Elevations have been updated. c. Staff is not supportive of the two individual windows on the front facades in the stair h all and recommends the applicant restudy this area. Since windows are on the front facades, we think the wall easily accommodates two separate units. d. Staff is not supportive of the blank areas of wall between the gables on the rear façade. S taff recommends adding windows in these areas – the interior configuration may need to be restudied. Plans cannot be reasonably reconfigured. e. Staff recommends centering the rear ground floor pedestrian door within the bay. Door is centered on Entry hall. f. The corner shed roof on the front façade appears too close to the edge of the building. T his should be pushed at least 6” in from the edge of the building. The end unit’s windows, doors, and shed roof also do not appear centered within the bay. Shed roof has been modified. g. The bays with triple-ganged windows do not have interior cornerboards. L arge corner bo ards are not in keeping with traditional siding details. h. A window could be added next to the garage doors. Elevations have been modifed. 4. Building 3 & 4: U nless specifically addressed, responses remain the s ame for Buildings 1 and 2 a. T he applicant shall provide fenestration to the left and right elevations as they are currently blank walls. b. Staff is not supportive of the two individual windows on the front facades in the stair h all and recommends the applicant restudy this area. c. Staff is not supportive of the blank areas of wall between the gables on the rear façade. S taff recommends adding windows in these areas – the interior configuration may need to be restudied. d. Staff recommends centering the rear ground floor pedestrian door within the bay. e. The corner shed roof on the front façade appears too close to the edge of the building. T his should be pushed at least 6” in from the edge of the building. The end unit’s windows, doors, and shed roof do not appear centered within the bay. f. The bays with triple-ganged windows do not have interior cornerboards. g. The rear shed roof should be pushed at least 6” in from the edge of the building. The s hed roof that protrudes beyond the edge of the wall creates an odd detail. Elevations have been modifed. h. Staff recommends pushing the rear first floor window so that it aligns with the second flo or window above (same comments applies to the single rear doors at the balcony and aligning these with the window above). Elevations have been modifed. i. A window could be added next to the garage doors. Streets: Kevin Sullivan Looking through a Complete Street lens. The sidewalk presentation looks good; it connects the homes to Meridian Road. The parking at the back of the community makes sense. The spacing of the driveway entrance to the community is good, however the radius is too generous in my opinion (my guess is that they chose that radius because they are thinking about fire truck maneuverability). I would like to see it match the radius at Carolyn Road. Otherwise, the renderings look very very nice - I believe this product has the potential to add some good value to the existing community The radius on Youmans Drive is based on SCDOT’s minim um 30’ radius and is unable to be reduced. St ormwater: I have no comment on the erosion and sediment control plans. Their conceptual approach of utilizing underground infiltration will suffice as long as it is sized to capture the SoLoCo volumes and the groundwater separation is maintained. They did not provide any stormwater or drainage computations or plans, so I can not review those items. Though as it appears to be a preliminary plat and sketch plan approval request, I assume their detailed design computations will be in a later stage. Site plans meet the City of Beaufort and SCDES draina ge standards with the use of permeable pavers and underground stormwater retention chambers. • Planning and Zoning: - You have a preliminary plat. Once you go to multi-family over a certain amount, it triggers an architectural review. We have removed the 6 unit buildings from the scope o f this project. Architectural review should no longer be required. o 100 ft max frontage width per building. Can allow a 10% administrative adjustment for the 5-unit building to meet this requirement, the 6-unit buildings will need to be revised or pursue a variance request. The 6 unit buildings have been removed from the scope of this project. The 5 unit building is 112’ long, we are requesting approval on the 5-unit building building. o Type D buffer along Meridian will be required. Path s/steps/stairs etc are permitted to be developed within the buffer. We have shifted the building along Meridian back 18’ off the R/W. We are requesting approval on the reduced 18’ buffer. The Whitehall Development only provides 13’ off the R/W as a buffer and we have exceeded that distance. • Architecture: o The architectural vocabulary continues to move generally in the direction of a traditional Lowcountry rowhouse/townhouse character using lap siding, masonry bases, porches/balconies, vertically proportioned openings, projecting entry roofs, and articulated roof forms. Confirmed. o The principal concern remains that the buildings ar e large three-story compositions containing repetitive attached units. Architectural refinement therefore needs to emphasize the individual townhouse scale, establish a clear hierarchy of architectural elements, and avoid reading as a single large repetitive multifamily building. We have given the exterior façade enough variation an d detailing to break up the massing without making the façade too complicated. o This is particularly important under the recently revised Section 4.5.6 Rowhomes/Townhouses provisions, which require housing model diversity and at least two distinctly different building designs reflecting traditional Beaufort Lowcountry architectural elements. We have given the design multiple exterior treatments in order to create interest in the façade. o Frontage Buildout: Refer to section 2.4.1.D.3. “building width at frontage is 100 ft max.” All buildings are under 100’, except for one, for which we are requesting a variance. o Review of Previous Architecture Comments o Building Height / Roof Massing — Still a Concern. Staff continues to recommend studying a somewhat lower primary roof slope and/or other refinements that visually reduce the prominence of the roof mass while retaining an appropriate Lowcountry roof form. Primary roof slope has been lowered. o Housing Model Diversity — Needs to be Demonstrated. The applicant should clearly identify the proposed building models and demonstrate how at least two designs are distinctly different while remaining architecturally compatible with one another. We have achieved a minimum of 3 distinct facades while maintaining overall architectural unity. o Individual Unit Identity / Color — Not Demonstrated. Staff continues to recommend development of a coordinated palette providing subtle variation between units and/or building groups. The intent is not to create excessive variety, but to reinforce the individual townhouse scale within the larger building composition. Subtle variation of colors have been included in the exterior design. o Window Sill / Trim Details — Still Needs Resolution. Provide revised window details demonstrating an actual projecting sill rather than simply an applied flat trim board below the window. Wall sections indicate actual projecting sill. o Masonry Base / Wall Plane — Still Needs Coordination. Applicant should continue studying the masonry/siding transition. Thin brick or another appropriately detailed masonry treatment may provide a cleaner relationship between the wall planes. Application of brick veneer at ground floor serves as a base at the building. The dimensional break in the wall plane reinforces this effect, lending a weight to the base. o Stoop Roofs — Still Appears Heavy. Staff recommends simplifying these elements and studying a slightly lower and lighter composition so that the entry roof remains subordinate to the primary façade. Front Porch roofs have been modified. o Porch / Balcony / Stoop Hierarchy — Partially Improved, Still Needs Coordination. Staff recommends establishing a consistent frontage strategy for each building or row—for example, one building/row emphasizing porches and another emphasizing balconies—rather than mixing frontage types indiscriminately. Variations in porch design have been used to create architectural interest. o Stair-Hall Fenestration — Still a Concern. Staff recommends further study of these openings so that they relate more naturally to the scale, proportion, and alignment of the other windows on the façade. Since windows are on the front facades, we think the wall easily accommodates two separate units. o Side Elevations / Blank Walls — Needs Confirmation. Final elevations should provide appropriately scaled and aligned fenestration on visible side elevations and avoid large uninterrupted areas of lap siding. Attention should be given to end units visible from Meridian Road, Youmans Drive, internal common areas, and adjoining properties. Elevations have been updated. o Rear Elevations — Needs Continued Refinement. Staff continues to recommend: o providing additional fenestration where large blank wall areas remain; Plans cannot be reasonably reconfigured to provide windows at these locations. o vertically aligning windows and doors where reasonably possible; Windows and doors have been aligned to the greatest extent possible. o centering pedestrian doors within their architectural bays; Door is centered on Entry Hall. o providing adequately scaled windows adjacent to garage doors where feasible; Elevations have been modified. o consistently extending the masonry-base architectural language into ground-level pedestrian-door recesses. Application of the brick veneer would reduce the width of the entry alcove by 10”. Use of siding at the entry alcoves also lightens the feel of the entry for the residents. o Shed Roof Placement — Needs Continued Refinement. Shed roofs should be inset from building corners sufficiently to allow the primary building corner and corner board to read clearly. Staff previously recommended approximately 6 inches minimum and continues to recommend this refinement. Elevations have been modified. o Corner Boards / Trim Continuity — Needs Coordinatio n. Provide corner boards and trim consistently at changes in wall plane rather than allowing siding to terminate without an intentional architectural transition. Large interior corner boards are not in keeping with traditional siding details. o Building 1 Porch / Awning Discrepancy — Needs Coord ination. All renderings, architectural elevations, floor plans, and landscape/site plans should depict the same architectural configuration in the next submission. Drawings have been coordinated. o Mechanical Equipment / Service Yards — Unresolved. Provide the location and screening design for HVAC equipment, meters, utilities, trash/service areas, and similar equipment. Architectural and landscape drawings should be coordinated. Architectural drawings have been updated to show HVAC equipment locations. o Materials and Colors — Still Required. The packet does not appear to include complete material/color selections or coordinated product information. At the next formal architectural submission, provide: o siding manufacturer/profile and exposure; o roofing material and color; o brick selection; o window manufacturer, material, profile, and color; o exterior doors; o railings; o columns and trim; o exterior lighting; and o proposed exterior paint/color palette. o Relevant selections should be clearly identified on product data. Material/color selections & product information will be provided at the future architectural submittal(s). We are requesting to be placed on Planning Commission for Sketch Plan and Preliminary Plat approval. Please find enclosed the following items for the referenced project: 1. Sketch Plan and Preliminary Plat Application 2. Project Narrative 3. Dominion Letter of Intent 4. Hargray Letter of intent 5. City of Beaufort Zoning Map 6. Beaufort County Zoning Map 7. BJWSA Approval 8. SCDES Approval 9. Topographic Survey 10. Preliminary Plat 11. Site Development Plans 12. Illustrative landscape plan 13. Landscape Plan w/ Tree Coverage Exhibit 14. Town Home renderings 15. Architectural Plans 16. Open Space Exhibit 17. Lot Coverage Exhibit 18. FEMA Flood Map We are requesting sketch plan and preliminary plat approval for the 69 Meridian R oad project. If you have any questions, comments or require additional information, please contact me at the office. Sincerely, Tim Brutcher PLS Carolina Engineering Consultants, Inc.

Source: City of Beaufort website. First collected Nov 14, 2026.