MEETING AGENDA
The City of Beaufort
HISTORIC DISTRICT REVIEW BOARD
Wednesday, March 12, 2025, 2:00 P.M.
City Hall, Council Chambers, 2nd Floor – 1911 Boundary Street, Beaufort, SC
Please click the link below to access the webinar:
https://us02web.zoom.us/j/87859260474?pwd=R1tEhzjALUvvhrA6nAZcDZ6LOof2i5.1
Password: 089323 Meeting ID: 878 5926 0474 Call in Phone #: 1+929 205 6099
STATEMENT OF MEDIA NOTIFICATION: “In accordance with South Carolina Code of Laws,
1976, Section 30-4-80(d), as amended, all local media were duly notified of the time, date, place, and agenda
of this meeting.”
Note: A project will not be reviewed if the applicant or representative is not present at the meeting.
I. Call to Order:
II. Review of Minutes:
A. February 12, 2025 Meeting Minutes
III. Applications
A. 1406 Greene Street, PIN R120 004 000 0241 0000, exterior renovations/alterations
Applicant: Lekshmi & Landon Poe, Homeowners
The applicant is requesting approval for several exterior renovations/alterations, including roofing,
shutters, stucco siding, front door, etc.
B. 510 Craven Street, PIN R120 004 000 0890 0000, addition
Applicant: Michael Frederick, Frederick + Frederick Architects
The applicant is requesting approval for a family room addition and partial enclosure of the rear
porch.
IV. Discussion
V. Adjournment
1
Historic District Review Board
Meeting Minutes – February 12, 2025
CALL TO ORDER 0:07
A meeting of the Historic District Review Board was held in-person on Wednesday, February 12, 2025 at
2:00 pm.
ATTENDEES
Members in attendance: Mike Sutton (Chair), Grady Woods, (Vice-Chair), Kim Petrella, Rita Wilson, and
Eric Berman.
Staff in attendance: Curt Freese, Community Development Director, Jeremy Tate, Meadors Architecture,
and Julie A. Bachety, Community Development Administrative Assistant II .
REVIEW OF MINUTES OF DECEMBER 11, 2024 0:23
Motion: Mr. Woods made a motion to approve the December 11, 2024 minutes as submitted. Mr.
Berman seconded the motion. The motion passed unanimously.
All Historic District Review Board Meeting minutes are recorded and can be found on the City’s website at
http://www.cityofbeaufort.org/AgendaCenter.
ELECTION OF OFFICERS 1:21
Motion: Mr. Woods nominated Kim Petrella for the position of Secretary. All Board members agreed.
The motion passed unanimously.
Motion: Mr. Woods nominated Eric Berman for the position of the Vice-Chairman. All Board members
agreed. The motion passed unanimously.
Motion: Mr. Woods nominated Mike Sutton to remain the Chairman. All Board members agreed. The
motion passed unanimously.
2
NOMINATION FOR WATERFRONT PARK COMMITTEE 12:33
Motion: Mr. Berman made a motion to nominate Mike Sutton to sit on the Waterfront Park Committee.
Ms. Wilson seconded the motion. The motion passed unanimously.
DISCUSSION 17:06
Mr. Sutton spoke about the new material study the HRB allowed to be done on the Cuthbert House to
use a synthetic porch decking. The project has now been completed, and Mr. Sutton went by last week
and took photographs and an inspection. He found it to be everything he hoped it to be. Now it’s a test
of time. He encouraged the other board members to go take a look at it. The next step for the board is
to watch the material over the next couple of years to see how it weathers on a hot day and a wintery
cold day.
Mr. Freese asked the board members if they would be interested in a spring or summer training. Mr.
Sutton suggested doing a walking tour of projects in Beaufort. Everyone agreed that April or May would
be best. Mr. Sutton said a list is put together of what would be good to look at. Mr. Freese will put
together an outline of ideas we want to visit (i.e.: new construction that’s been recently approved and
how it fits the conducts of the neighborhood; how new materials are holding up at Cuthbert House; look
at 1401 Duke Street, and properties that have been recently stabilized.
Mr. Freese spoke reminded the board members of the Strategic Plan that has been rescheduled for
February 24 – 26. The Chairman has a seat for it. Mr. Sutton said he is not available. Mr. Berman said
he can attend Monday and Tuesday.
ADJOURNMENT 34:27
Mr. Woods made a motion seconded by Ms. Petrella to adjourn. The meeting ended at 2:34 pm.
1406 GREENE STREET
Discussion/Approval of major
renovations proposed on the exterior of
existing residential house
(non-contributing, ca. 1965)
CITY OF BEAUFORT
HTRC – Pre-Design Application Meeting
1911 BOUNDARY STREET
BEAUFORT, SOUTH CAROLINA 29902
(843) 525-7011 FAX: (843) 986-5606
Meeting Summary
Date: 2/5/2025
Project Address: 1406 Greene Street
Project Narrative: Discussion on proposal for several exterior house improvements, including
roof, shutters, stucco siding, front door, etc.
Applicant: Lekshmi Poe (Homeowner)
Synopsis of staff comments:
• Planning and Zoning:
o Noncontributing Structure
• Building Codes:
o Windows will need to comply with the Energy Code
• Architecture:
o From previous HTRC meeting:
5V crimp roof can be approved but staff strongly recommends either a
standing seam mechanical lock metal roof or replacement in-kind of
asphalt shingle. Staff supports the example roof at 2302 Simms Street
(corner of Bay Street and Ribaut Road).
Staff has no objections to keeping the existing metal columns as noted by
HBF. Staff does support the replacement of these columns with cedar
columns with a simple cap and base. Please note the dimensions and
details of the columns in any future submitted drawings.
Staff recommends keeping the existing windows where possible, and
supports the addition of a storm window for added energy efficiency. If
window replacements are preferred, please submit photos of the existing
windows to be replaced and describe their conditions/why they warrant
replacement. Vinyl windows are not supported, and staff would prefer
either a wood or fiberglass product. See the Beaufort Preservation Manual
for additional window information.
Staff has no objections to the request to enclose the kitchen door and
convert the rear bedroom window with a door. Please note the changes in
plan and elevation drawings.
Staff prefers the applicant keep the CMU block and clean and paint the
CMU. If the applicant would like to use board and batten, please provide
any details such as window sills, casings, cornerboards, skirtboards, siding
to soffit connections, etc. Applicant should also note the dimensions of the
boards and battens, profiles, specific product cutsheet, etc.
o Applicant is proposing a snap-lock roof in “Aged Copper” (Patina Green), staff
supports the provided roof profile in “smooth panel structure” – provide
manufacturer’s details for eave/ridge/hip connections. Staff would like to see a
sample of the proposed roof color as the digital image is hard to judge.
o Applicant is proposing Kolbe Forgent windows – drawings appear to show a2
horizontal lite over 2 horizontal lite pattern. Staff is in support of this, but
applicant to note that windows must have exterior SDL grilles with interior spacer
bars – spacer bars (GBG) only is not allowed in the historic district.
o Staff does not support the proposed idea to install 3x3 galvanized steel beams as
columns on the front porch – this is not appropriate for the Beaufort historic
district and especially not on a residential structure, regardless of age. Staff
recommends either keeping the existing columns or reverting back to the 6x6
cedar columns, which staff had previously supported.
o Applicant is proposing white smooth stucco, Staff is in support
o Staff supports the Bermuda shutter selection. Staff recommends the shutters be
painted. Transparent finish sapele, in Beaufort’s environment, will require
constant maintenance to keep the shutters in good condition. A painted shutter
will last longer and be easier to maintain.
o The proposed front door is not in keeping with the style of the house nor with
Beaufort’s Historic District. Staff recommends the applicant select another design
that is consistent with the district and style of the house. Also, the hammered steel
entry door handle set seems at odds with the mid-century modern house.
o As a simple recommendation, staff recommends selecting a different fan and
lantern. Applicant seems to be going for a more modern, simplistic design, and
would recommend a simple rectangular lantern and fan without the cage.
o Staff does not support gas lanterns on buildings and recommends the light be the
electric version. Gas lanterns historically were not used on residences but rather
were used for street lighting.
o Staff does not support staining the exposed soffit eaves and rafters as this is not
consistent with other structures in the district. Staff recommends painting these
features.
• HBF:
o Retain the midcentury narrative- windows, cmu, porch columns
Applicant’s Next Steps: Apply for March 12
th HRB hearing, have documentation ready by
February 28th to meet the March 12th deadline.
Be advised that this letter is given as a courtesy to applicants and may not contain all project guidelines.
For a complete history of the meeting, please request the audio recording. Please refer to the Beaufort
Code for applicable sections. If there are any changes to the project, not discussed in this meeting, you
will need to return to a HTRC – Pre-Design meeting.
If you have any questions, feel free to call the Community Development Department at (843) 525-7014.
Thank you for your patience and cooperation during the review process.
Sincerely,
City of Beaufort Community Development
STAFF REPORT: Historic District Review Board
(HRB)
1406 GREENE STREET – Approval
DATE: March 12, 2025
Background: The applicant has already been to the Historic District Review Board (HRB) to present a list
of renovation items to the exterior of the non-contribution, mid-20th century CMU house on 1406 Greene
Street. After the HRB’s meeting on July 10, 2024 the applicant was presented a Decision Letter for
approval of her request with a total of ten (10) conditions:
1. Applicant provide a cutsheet showing specific detail on green standing seam metal roof.
2. Applicant to provide a cutsheet for the new front and rear doors.
GENERAL INFORMATION
Applicant: Lekshmi & Landon Poe (Homeowner)
Site Location/Address: 1406 Greene Street; R120 004 000 0241 0000
Applicant's Request: Applicant is proposing several exterior renovations/alterations, including
roof, shutters, stucco siding, front door, etc.
Current Zoning: T4-HN
Contributing/Neighborhood Non-Contributing (built ca. 1965) as per Nat’l Register of Historic Places
Flood Zone/Base Flood Flood Zone X, Elevation: ~23’-25’
Existing Trees Large Landmark tree (either a Laurel or Live Oak) right at the property line
on adjacent property.
ZONING DISTRICT INFORMATION
T4-HN
Lot Width at Setback: 40 ft min, 60 ft min in The Point
Max Lot Coverage: 55% of lot area
Min. Frontage Build Out 75% max
Front Setback Average Prevailing Setback on Block
Side Setback Corner: 5 ft min (corner); Interior: 6 ft min, 10 ft min in The Point
Rear Setback 15 ft min
Building Height: 3 stories max
SURROUNDING ZONING, LAND USE AND REQUIRED BUFFERS
Adjacent Zoning Adjacent Land Uses Setbacks for Adjacent Zoning
/Buffer required if rezoned
North: T4-HN Residential home, non-contributing N/A
South: T4-HN Infill development (residential) N/A
East: T4-HN Historic home (c. 1910) N/A
West: T4-HN Historic home (c. 1870, abandoned) N/A
2
3. The drawings depict two over one windows, which are different from the existing windows with
no vertical muntins. If the applicant is planning to replace all windows, a cutsheet from the
window manufacturer must be provided.
4. Reconsider the new wood columns appear too wide and ornate for the building. Staff recommends
reducing the size of the columns and simplifying the column caps. Staff also recommends adding a
simple column base.
5. Remove the use of tabby as a foundation material.
6. Reconsider the new stucco and siding on the left and right (east and west) facades and how it is
applied on the existing CMU and terminates 12’ from the front plane. Since the CMU wall is one
continuous plane, these new materials would be applied directly to the face of the CMU, leaving
the edge as an awkward termination that shows the depth of the siding and cornerboard,
skirtboard, and stucco. If the applicant wishes to add the stucco and siding, this should be added
around the entirety of the building or not added at all.
7. Reconsider utilizing a new siding material, consider either board and batten siding or lap siding,
instead of using both and changing the material on each façade. Please note that lap siding is
shown on the elevation drawings, but the note calls out board and batten siding.
8. Applicant to provide typical window head, sill, and jamb details, especially for the windows
surrounded by new siding. Staff has concerns that the new casings and sills will be too “flat” on the
CMU portions in comparison to the ones in the proposed new siding areas. Staff is concerned with
how the applicant will case the windows in the CMU walls and connect to the existing masonry
sills. As drawn, these areas appear as picture framed casing which is not allowed per the Beaufort
Code. The windows must have a projecting sill.
9. Applicant appears to be adding Bermuda shutters on two of the left (west) façade windows.
Provide a cutsheet for the shutters and note that they must be operable.
10. Applicant depicts exposed rafters around the building that do not currently exist. Applicant to
show a typical wall section that shows the new exposed rafters.
Updated request / further provided details by applicant for HRB approval:
The applicant at the last HTRC Meeting on February 5, 2025, has provided City staff with the following
updated information in relation to proposed exterior materials (also in response to above conditions):
Exterior Materials proposed:
Feature Material Color
Roof Standing seam snap-lock
metal roof (Manufacturer:
GulfCoast; Material: 24 gauge
steel; standing seam: 1-1/2”;
Patina green
3
16” panel coverage; smooth
panel structure)
Exterior Cladding Smooth Stucco
(Manufacturer: Omega
Products; 30/30 Float Finish)
White (“Omega White”)
Front Doors: Wood (solid hardwood) with
three vertical textured glass
window panes running down
the entire length including
“Bullock” Entrance Door Set
with Round Knob ( 2-3/8”
Backset, Dark Bronze); (Door
manufacturer: Creative
Entryways; Size: 36” x 79” x
1-3/4”)
Dark Walnut (Paint
manufacturer: Varathane –
One-Step Stain &
Polyurethene)
Soffit eaves/rafters Exposed and stained Dark Walnut (Paint
manufacturer: Varathane –
One-Step Stain &
Polyurethene)
Windows: Fiberglass 1 x 2 / 1 x 2 grid
(double hung)
(Manufacturer: Kolbe
Forgent Series); variable
sizes
White
Window sills Stucco overhang White
Front porch columns Galvanized steel metal
beams, 3” x 3”
Patina green
4
Bermuda shutters Sapele wood, stained with
operable louvers; variable
sizes
Dark Walnut
Gas lantern (front porch) Charleston Flush Mount
Copper Gas or Electric Wall
Lantern; Size: 17.5” x 10.5”
(Manufacturer: Arranmore)
Raw Copper
Front porch ceiling fan Blynn – LED lit
Indoor/Outdoor fan; Size:
22” x 16.5” (Manufacturer:
Arranmore)
Charred Iron
Tree Removal Proposed:
No trees are proposed to be removed.
Surrounding Area:
This property is located in the Northwest Quadrant. The buildings on the block and surrounding area are
made up of historic structures. Most of the buildings are one story in height, with a few two-story
buildings throughout. The specific residential is a mid-1960’s CMU-dwelling, which therefore is regarded
as a non-contributing resource on the National Register of Historic Places for the Beaufort Historic
District.
Determination of adequate historic integrity for New Construction, Infill, Additions and
Demolition:
As per the Beaufort Preservation Manual (Chapter 5) and the Beaufort Development Code (Section 4.7),
new infill construction as well as major renovations to existing structures must be conducted in
consideration to the architectural fabric of the community. This can be successfully achieved by adhering
to the following principles: 1. Location, 2. Design, 3. Setting, 4. Materials, 5. Workmanship, 6. Feeling
and 7. Association. As per these guidelines, following staff analysis determines the integrity of this major
renovation request.
5
4.7.2 Integrity Guidelines (as per
Beaufort Development Code)
Rationale
Present
(yes/no)
Staff Analysis of Rationale
1. Location: This is the relationship
between the property and its historical
context.
Yes ✓ The CMU-dwelling from ca. 1965 can be
historically tied to many similar houses
in the Northwest Quadrant
neighborhood.
2. Design: This is the combination of
elements that create the feeling of a district
or structure. These elements include
building patterns, streetscapes, site
elements, building size, mass and scale,
spatial relationships, and specific
architectural elements and details.
No X There are many proposed design
elements that are neither compatible
with the historic theme of the
neighborhood nor representative with
the period of its original construction
(mid-century).
3. Setting: This is the physical environment
of a property and should be evaluated on
its context as well as on the historical role
the property has played and continues to
play. Important features include
topography, vegetation, man-made
features, and relationships between
existing structures and their surroundings.
Yes & No ✓ The surrounding properties are mainly
residential dwellings of smaller size
(mostly 1-story bungalows). Therefore,
this residential retrofit complies with its
surroundings in use and scale.
X Man-made feature may be altered too
much to be representative of its historic
setting.
4. Materials: These are the physical
elements that make up a property or
district.
No
X Many of the proposed architectural
design features do not comply with the
visual texture of the Northwest
Quadrant.
5. Workmanship: This is the physical
evidence of the crafts of a particular culture
or time period. This particularly applies to
rehabilitation projects, but for new infill
projects, workmanship of surrounding
structures should be considered and
respected. Retaining the details of the
original craft and craftsman (i.e., wood,
Yes & No ✓ The proposed renovations are much
needed and generally represent a major
improvement to the workmanship of
this specific property.
X However, the proposed exterior design
details are not representative of the
historic design era of the original
6
masonry, tabby etc.) of the original building
ensures the historic fabric is retained and
serves as an important component of the
integrity and the patina of age of individual
structures and the district as a whole.
structure (mid-century) nor are they
representative to the historic fabric of
the surrounding neighborhood.
6. Feeling: This is the property's
expression of the aesthetic or historic sense
of a particular period of time. This
particularly applies to rehabilitation
projects, but for new infill projects, the
feeling of surrounding structures should be
considered and respected.
No
X The proposed design features neither
aesthetically represent the historic
period of the building (mid-century) nor
does it help to reinstate the historic
feeling of the neighborhood.
7. Association: This is the direct link
between an important historic event or
person and a property. This particularly
applies to rehabilitation projects, but for
new infill projects, association of particular
sites and neighborhoods considered.
N/A ✓ Staff has not found any relevant history
or persons directly linked to this
specific property.
Synopsis of staff comments from last Historic District Technical Review Committee (HTRC)
Meeting on February 05, 2025:
• Planning and zoning:
➢ Non-contributing structure
➢ Zoned T4-HN
• Building Codes:
➢ Windows will need to comply with the Energy Code
• Architecture:
➢ Roof:
o Applicant is proposing a snap-lock roof in “Aged Copper” (Patina Green), staff supports the
provided roof profile in “smooth panel structure” – provide manufacturer’s details for
eave/ridge/hip connections. Staff would like to see a sample of the proposed roof color as the
digital image is hard to judge.
➢ Exterior cladding:
o Applicant is proposing white smooth stucco. Staff is in support.
➢ Front door:
o The proposed front door is not in keeping with the style of the house nor with Beaufort’s Historic
District. Staff recommends the applicant select another design that is consistent with the district
and style of the house. Also, the hammered steel entry door handle set seems at odds with the mid-
century modern house.
➢ Soffit eaves/rafters:
7
o Staff does not support staining the exposed soffit eaves and rafters as this is not consistent with
other structures in the district. Staff recommends painting these features.
➢ Windows:
o Applicant is proposing Kolbe Forgent windows – drawings appear to show a2 horizontal lite
over 2 horizontal lite pattern. Staff is in support of this, but applicant to note that windows must
have exterior SDL grilles with interior spacer bars – spacer bars (GBG) only is not allowed in the
historic district.
➢ Front porch columns:
o Staff does not support the proposed idea to install 3x3 galvanized steel beams as columns on
the front porch – this is not appropriate for the Beaufort historic district and especially not on a
residential structure, regardless of age. Staff recommends either keeping the existing columns
or reverting back to the 6x6 cedar columns, which staff had previously supported.
➢ Bermuda shutters:
o Staff supports the Bermuda shutter selection. Staff recommends the shutters be painted.
Transparent finish sapele, in Beaufort’s environment, will require constant maintenance to
keep the shutters in good condition. A painted shutter will last longer and be easier to maintain.
➢ Gas lantern:
o Staff does not support gas lanterns on buildings and recommends the light be the electric
version. Gas lanterns historically were not used on residences but rather were used for street
lighting.
➢ Outdoor front porch ceiling fan:
o As a simple recommendation, staff recommends selecting a different fan and lantern. Applicant
seems to be going for a more modern, simplistic design, and would recommend a simple
rectangular lantern and fan without the cage.
• HBF Recommendation:
o Retain the mid-century narrative, including windows, CMU, porch columns
FINDINGS AND RECOMMENDATIONS
Staff Recommendation:
Staff recommends f inal approval of the proposed renovations , in that it satisfies the intent of the
Beaufort Preservation Manual and requirements of the Beaufort Code , with the following
conditions:
1) Staff supports the proposed standing seam metal roof in the patina green color with smooth
panel finish , but staff would recommend a flat “smooth” panel in between the seams as
opposed to the striations in each panel.
2) Staff supports the proposed white smooth stucco finish.
8
3) Staff believes that the proposed front door is not in keeping with the style of the house nor
with Beaufort’s Historic District. Staff recommends the applicant select another design that is
consistent with the district and style of the house. Also, the hammered steel entry door handle
set seems at odds with the mid-century modern house – staff recommends selecting different
hardware.
4) Applicant is proposing Kolbe Forgent windows. Staff supports this window selection , but
applicant to note that windows must have exterior SDL grilles with interior spacer bars –
spacer bars (GBG) only is not allowed in the historic district. Additionally, the window sheet
notes that the window will be a 1x2/1x2 lite pattern, but the picture appears to show a
2x2/2x2 pattern. Applicant to submit a clearer photo that depicts the lite person. Sheet A201
also shows a more traditional 2/1 window pa ttern, this sh ould be amended to reflect the
proposed lite pattern.
5) Staff does not support the proposed 3x3 galvanized steel beams as columns on the front porch
– this is not an appropriate detail for the Beaufort Historic District, and especially not on a
residential structure, regardless of age. Staff recommends either keeping the existing columns
or reverting back to the 6X6 wood columns, which staff had previously supported.
6) Staff supports the Bermuda shutter selection , but recommends the shutters be painted.
Stained sapele , in Beaufort’s environment, will require constant maintenance to keep the
shutters in good condition. A painted shutter will last longer and be easier to maintain.
7) Choose a different kind of front porch lamp (rectangular shaped) , but not a gas lantern, as
those were not commonly used for house lights in historic Beaufort;
8) Staff recommends selecting a different fan and lantern. The applicant appears to be aiming for
a more modern, simplistic design, and would recommend a simple rectangular lantern and fan
without a cage.
9) Staff does not support gas lanterns on buildings and recommends the lights be electric. Gas
lanterns were historically not used on residences but rather were used for street lighting.
10) Staff does not support staining the exposed soffit eaves and rafters as this is not consistent
with other structures in the district. Staff recommends painting these features.
510 CRAVEN STREET
Approval of minor addition and changes
to back porch and stairs at existing
residential house
(contributing, ca. 1885)
HISTORIC REVIEW APPLICATION
MAJOR REVIEW (HISTORIC REVIEW BOARD)
Community Development Department
1911 Boundary Street, Beaufort, South Carolina, 29902 Application Fee:
p. (843) 525-7011 / f. (843) 986-5606 see attached schedule
Email: development@cityofbeaufort.org / Website: www.cityofbeaufort.org
OFFICE USE ONLY: Date Filed: __________________ Application #: ______________
Zoning District: _______________
____________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________
• HAS PROJECT ATTENDED HTRC MEETING? (REQUIRED) YES NO
• IS PROJECT A CONTRIBUTING STRUCTURE?
O OR NON-CONTRIBUTING STRUCTURE:
FOR A LIST OF CONTRIBUTING OR NON-CONTRIBUTING STRUCTURES, PLEASE SEE:
https://cityofbeaufort.org/350/Beaufort-County-Historic-Sites-Survey
APPLICABILITY FOR HISTORIC REVIEW BOARD: Major discretionary review board (HDRB) approval shall apply
to applications for Certification of Appropriateness per Section 9.10.2 for the following requests (please check all that apply):
New building(s) in Historic District
Changes to exterior materials of Contributing Structures
Additions to Contributing Structures
Non-similar roof replacement on Contributing Structures (roof with different materials)
Window replacements on Contributing Structures
Major changes to a Contributing or Non-contributing Site
Demolition
Other changes to exterior of Contributing Structures
SUBMITTAL REQUIREMENTS: All forms and information shall be submitted digitally + 5 hard copies of all documents. In
addition to a complete application form, applicants shall submit the required items according to the checklists on the subsequent page.
Pursuant to Section 6-29-1145 of the South Carolina Code of Laws, is this tract or parcel restricted by any recorded covenant
that is contrary to, conflicts with, or prohibits the activity described in this application? Yes No
APPLICANT, PROPERTY, AND PROJECT INFORMATION:
APPLICANT NAME:
APPLICANT ADDRESS:
APPLICANT E-MAIL: APPLICANT PHONE NUMBER:
APPLICANT TITLE: Homeowner Tenant Architect Engineer Developer
HISTORIC REVIEW APPLICATION
MAJOR REVIEW (HISTORIC REVIEW BOARD)
Community Development Department
1911 Boundary Street, Beaufort, South Carolina, 29902 Application Fee:
p. (843) 525-7011 / f. (843) 986-5606 see attached schedule
Email: development@cityofbeaufort.org / Website: www.cityofbeaufort.org
OW
NER (IF OTHER THAN THE APPLICANT):
OWNER ADDRESS:
PROPERTY ADDRESS:
PROPERTY IDENTIFICATION NUMBER (TAX MAP & PARCEL NUMBER):
PROVIDE A BRIEF PROJECT NARRATIVE: (Attach any necessary documentation, spec sheets, pictures, paint swatches, etc.):
CERTIFICATION OF CORRECTNESS: I/we certify that the information in this application is correct.
APPLICANT’S SIGNATURE: DATE: _____
OWNER’S SIGNATURE: _________________________________ DATE: __________________
(The owner’s signature is required if the applicant is not the owner.)
SCH
EDULE:
The Historic Review Board (HRB) typically meets the 2nd Wednesday of each month at 2pm. Staff will schedule
HRB meeting after HTRC and review of application submittal for completeness and compliance with the
Beaufort Preservation Manual and the City of Beaufort Development Code.
CONTACT INFORMATION:
City of Beaufort Community Development Department
1911 Boundary Street, Beaufort, South Carolina 29902
E-Mail: development@cityofbeaufort.org | Phone: (843) 525-7011 | Fax: (843) 986-5606
City of Beaufort Certificate of Appropriateness Checklists
1
Revised Dec. 10, 2021
Revised June 10, 2021
HISTORIC DISTRICT REVIEW BOARD
CERTIFICATE OF APPROPRIATENESS
Application Requirements
The Beaufort Code applies to all projects; the Historic District Infill Design Guidelines in
Section 4.7 apply to new construction in the Historic District.
The Historic Review Board also utilizes the following documents when evaluating projects:
• The Beaufort Preservation Manual & Supplement: these standards apply to New
Construction, Alterations and Additions to Contributing Structures, and Demolition
located everywhere in the Historic District except the Northwest Quadrant.
• The Northwest Quadrant Design Guidelines: these standards apply to New Construction,
Alterations and Additions to Contributing Structures, and Demolition located in the
Northwest Quadrant of the Historic District
• The Secretary of the Interior’s Standards for Rehabilitation: these standards apply to all
modifications to Contributing Structures throughout the Historic District
All documents can be found online at www.cityofbeaufort.org
• The Beaufort Code can be found here: http://www.cityofbeaufort.org/434/Zoning
• Documents specific to the Historic District, a map of the Historic District and
neighborhoods, and the list of Contributing and Non-Contributing Structures can be
found here: http://www.cityofbeaufort.org/350/1997-Beaufort-County-Historic-
Sites-Surv
NOTE 1: If a New Construction project also requires major demolition a separate
application is required. (Refer to the Checklist for Demolition on page 3).
NOTE 2: Applications will not be considered complete until all the required items
have been submitted. Incomplete applications will not be placed on the agenda.
NOTE 3: Applications are to be compiled in the order in which the applicant plans to
present the application to the Board during the meeting.
City of Beaufort Certificate of Appropriateness Checklists
3
Revised Dec. 10, 2021
Submission Requirements for Change After Certification
Please submit DIGITAL FILES ONLY via email to: development@cityofbeaufort.org
Change After Certification:
□ Copy of Certificate of Appropriateness received with previous approval.
□ Previously Approved Drawings: Applicant to submit complete set of previously approved documents. Current
proposed documents to be interlaced between previously approved documents and must be formatted to match
previously approved. For example, previously approved elevations should be followed by current proposed.
Drawings to be clearly noted as “Previously Approved” or “Current Proposed”, and all proposed revisions in the
current proposed drawings must be clouded and noted.
Sheet
Number Sheet Name
0.0 TITLE SHEET
A1.0 SITE PLAN AND EXISTING SURVEY
A2.1 PLANS
A3.1 ELEVATIONS
A3.2 3D VIEWS
A4.1 BUILDING AND WALL SECTIONS
2024 All Rights ReservedC
1
A4.3
1
A4.1
1
A5.1
1
15.75'
A
1
1
GYPSUM WALLBOARD
(LARGE SCALE)
ACOUSTIC TILE
CARPET & PAD
GYPSUM WALL BOARD
(ELEVATION)
FLASHING, ETC
BRICK (ELEVATION)
HORIZONTAL SIDING
(ELEVATION)
ROOF SHINGLES
(ELEVATION)
WATERPROOFING, FELT,
CONTINUOUS
BLOCKING
ROUGH LUMBER
ROUGH LUMBEREARTH
GRAVEL
FINISH WOOD
INSULATION BATTS
RIGID INSULATION
PLYWOOD (LARGE SCALE)
PLYWOOD (SMALL SCALE)
CONCRETE
C.M.U.
BRICK
STEEL
DETAIL-NO.
SHEET-NO.
ENLARGED
DETAIL INDICATOR
SHEET-NO.
DETAIL-NO.
SECTION CUT INDICATOR
INTERIOR ELEVATION INDICATOR
WINDOW MARK
DOOR MARK
ELEVATION ABOVE MEAN SEA LEVEL
DETAIL-NO.
SHEET-NO.
OR OTHER SPECIFIED DATUM
WALL TYPE
REVISION NUMBER
Refrigerator
Roof Drain
Radius
Riser
Room
Roof Joist
Required
Revision
Reinforcing
Rough Opening
Sheet
Shelf
Schedule
Square Foot
Square
Specification
Similar
Solid Masonry Pier
Stainless Steel
Solid Core Wood
Telephone
Tread
Suspended
Steel
Top of Steel
Through
Threshold
Thick
Top of Plate
Typical
Top of Slab
Without
Wood
With
Vertical
Unless Otherwise Noted
Verify in Field
Vinyl Composition Tile
Top of Sheathing
Standard
Quanity
R.
Floor
Foot
FL.
F.D.
GA.
FT.
F.J.
Hose Bib
GYP.BD.
GALV.
H.M.
HCWD.
H.B.
Gauge
Hollow Metal
Gypsum Board
Galvanized
Floor Joist
Floor Drain
Hollow Core Wood
Height
Lavatory
Laminate
Kitchen
HGT.
HORIZ.
LAV.
LAM.
KIT.
Masonry
Light
Maximum
LT.
MAS.
MEMB.
MECH.
MAX.
Membrane
Mechanical
Horizontal
A.F.F.
ADJ.
ABV.
BD.
APPROX.
ANG.
ALT.
ALUM.
Board
Approximate
Angle
Alternate
Aluminum
Above Finish Floor
Adjacent
Above
BOT.
BSMT.
BM.
BLKG.
L
CLO.
CLG.
C.T.
C
CAB.
Closet
Ceiling
Ceramic Tile
Center Line
Cabinet
Bottom
Basement
Beam
Blocking
BuildingBLDG.
T.Minimum
MFR.
MET.
M.O.
MISC.
MIN.
N.I.C.
O.D.
O.C.
N.T.S.
Outside Diameter
On Center
Not To Scale
Not In Contract
Masonry Opening
Miscellaneous
Manufacturer
Optional
Plate
Precast
OPT.
OPNG.
PL.
P.LAM.
P.C.
Pair
Plywood
PR.
PLYWD.
P.S.I.
P.S.F.
P.T.
Pounds Per Square Inch
Pounds Per Square Foot
Pressure Treated
Plastic Laminate
Opening
CONC.
COL.
CMU.
C.O.
DIA.
D.F.
DTL.
DEPT.
CONT.
Dimension
Diameter
Drinking Fountain
Detail
Department
Continuous
Concrete
Column
Concrete Masonry Unit
Cased Opening
EA.
DWG.
DS.
DN.
EQUIP.
EQ.
EMER.
ELEC.
EL.
E.J.
Equipment
Equal
Emergency
Electrical
Elevation
Expansion Joint
Each
Drawing
Down Spout
Down
DIM.
Metal
CentimeterCM.
ExteriorEXT.
UON.
S.M.P.
REF.
W/O
WD.
W/
V.I.F.
VERT.
VCT.
TYP.
T.O.SL.
T.O.SH.
T.O.S.
T.O.P.
THRU.
THRES.
THK.
TEL.
SUSP.
STL.
STD.
S.S.
SQ.
SPEC.
SIM.
SHT.
SH.
SCWD.
SCHED.
R.O.
RM.
R.J.
REQD.
REV.
REINF.
R.D.
RAD.
QTY.
S.F.
Weight
Welded Wire Fabric
P.V.C. Polyvinyl Chloride
E.W.
EXIST.
Each Way
Existing
WWF
WT.
WaterproofingPainted WP.PTD.
SYMBOLS INDEX OF DRAWINGSSPECIFICATIONSABBREVIATIONS
MATERIALS
EXTERIOR ELEVATION INDICATOR
A5.1
1
SHEET-NO.
DETAIL-NO.
LOCATOR MAP BUILDING INFORMATION
3
24
Finished Room Over GarageFROG
NOT FOR
CONSTRUCTION
2/28/2025 11:03:18 AM
0.0
TITLE SHEET
GASKIN RESIDENCE
HRB
REVIEW
510 CRAVEN STREET
2.28.2025
GASKIN RESIDENCE
510 CRAVEN STREET
LIVE OAK
EXISTING
TERRACES
MAIN HOUSE
EXISTING GUEST
HOUSE
EXISTING
PARKING
EXISTING PORCH
TO BE ENCLOSED
EXISTING PORCH TO
REMAIN
NEW WOOD STAIR
NEW BRICK ON
GRADE STAIR
LANDING
EXISTING GATE
TO REMAIN
EXISTING
POTOCARPUS
HEDGE
TO REMAIN
NEW GARDEN
SHED
2024 All Rights ReservedC
NOT FOR
CONSTRUCTION
2/28/2025 11:03:19 AM
A1.0 SITE PLAN AND EXISTING SURVEY
GASKIN RESIDENCE
HRB
REVIEW
510 CRAVEN STREET
2.28.2025
N
1" = 10'-0"1 SITE PLAN
3
A4.1
1' - 0"
1' - 8"
1' - 0"
8"2' - 8"1' - 0"
CENTER NEW PIER
ON EXISTING PIER
NEW LATTICE TO MATCH EXISTING
NEW CMU PIERS WITH
STUCCO FINISH TO MATCH
EXISTING ON 8"X16" CONC.
FOOTING
EXISTING FOUNDATION TO REMAIN
REMOVE EXISTING STAIR
NEW BRICK STAIR LANDING ON GRAVEL BASE
EXISTING BBQ
RELOCATE GAS PIPING TO BBQ GRILL
90.00°
90.00°
8' - 4"
7' - 0"
5
A4.1
1
A4.1
3' - 4" 2' - 4"
EXISTING
FOUNDATION
= EXISTING
= NEW
CUT PATTERN
= EXISTING
= NEW
SURFACE PATTERN
PHASE LEGEND
2024 All Rights ReservedC
NOT FOR
CONSTRUCTION
2/28/2025 11:03:21 AM
A2.0 FOUNDATION PLAN
GASKIN RESIDENCE
HRB
REVIEW
510 CRAVEN STREET
2.28.2025
1/4" = 1'-0"1 FOUNDATION
1/4" = 1'-0"
PHASE LEGEND
PV PANELS
PV PANELS
A3.1
A3.1
1
2
3
A4.1
NEW STREET
A4.1 2
3
5
A4.1
2' - 4" 2' - 0" 2' - 8"
GARDEN
TOOLS
1
A4.1
EXISTING CABINETS
TO REMAIN
NEW FLOOR TO
MATCH EXISTING
NEW
SCONCE
NEW
FAN
NEW STEP LIGHTS
4" CONC. SLAB BELOW
BRICK FINISH
2X2
LED
NEW BRICK ON
GRADE STAIR
LANDING MATCH
EXISTING
EXISTING GATE
TO REMAIN
EXISTING
POTOCARPUS
HEDGE
TO REMAIN
RELOCATE GAS LINE TO GRILL
EXISTING WALKS TO REMAIN
EXISTING WALKS
TO REMAIN
PORCH
FAMILY
ROOM
GARDEN
SHED
TERRACE
2' - 8" 3' - 4" 2' - 4"
8' - 4"
7' - 8 1/2"
NEW WOOD STAIRS 15" TREADS SEE DETAIL SHEET A4.1
6X6 POSTS
LOUVERED PANELS
EXISTING
HOLLY TO
REMAIN
3
A4.1
EXISTING DROPPED BEAMS
NEW DROPPED BEAMS
TO MATCH EXISTING
1X6 T&G CYPRESS CEILING
W/ CLEAR FINISH
1
A4.1
NEW CEILING FAN
MOTORIZED
SHADES
MOTORIZED
SHADES
= EXISTING
= NEW
CUT PATTERN
= EXISTING
= NEW
SURFACE PATTERN
PHASE LEGEND
2024 All Rights ReservedC
NOT FOR
CONSTRUCTION
2/28/2025 11:03:22 AM
A2.1 PLANS
GASKIN RESIDENCE
HRB
REVIEW
510 CRAVEN STREET
2.28.2025
1/8" = 1'-0"2 ROOF PLAN
1/4" = 1'-0"1 FIRST FLOOR
1/4" = 1'-0"3 FIRST FLOOR CEILING PLAN
REPLACE EXISTING DECKING
W/ KDAT 5/4X4 T&G PAINTED
TO MATCH EXISTING
NEW CMU PIERS WITH STUCCO
FINSH TO MATCH EXISTING
LATTICE TO MATCH EXISTING
NEW DOOR AND
TRANSOM UNIT 2 1/4"
SAPELE PAINTED TO
MATCH TRIM
NEW CASEMENT
WINDOWS TO
MATCH
EXISTING
NEW 5" 1/2 ROUND
GUTTER
AND 4" DOWNSPOUT
MATCH ROOF COLOR
NEW RAILING TO MATCH
EXISTING REAR RAILING
NEW STAIR 6" RISERS 15" TREADS SEE DETAIL A4.1
EXISTING CASEMENT WINDOWS
NEW CASEMENT WINDOWS TO
MATCH EXISTING
EXISTING WOOD PANEL
NEW WOOD STAIR
EXISTING FOUNDATION TO REMAIN
NEW AWNING WINDOWS
NEW BAND BOARD TO MATCH EXISTING
BUILD ING TO REMAIN AS IS
NEW SOLAR PANELS ON EXISTING
LOW PITCHED ROOF
GUEST HOUSE TO REMAIN
AS IS EXCEPT NEW SOLAR PANELS
AND GARDEN SHED
5
A4.1
NEW GARDEN SHED
STUCCO BASE TO MATCH EXISTING FOUNDATION
SHUTTER PANELS TO MATCH EXISTING
2X WOOD SILL
WOOD PANEL PAINT TO MATCH
FOUNDATION
2X WOOD FRAME
1
A4.1
5" 1/2 ROUND GUTTER W/ 4" ROUND
DOWN SPOUT MATCH ROOF COLOR
EXISTING ROOF RETURN
MATCH EXISTING ROOF
RETURN HERE
4' - 5"
ROOF TO MATCH EXISTING
STUCCO TO MATCH EXISTING
PAINT TO MATCH EXISTING
LOUVERS TO MATCH EXISTING
2 1/4" SAPELE DOOR W/ LOUVERED PANEL
= EXISTING
= NEW
CUT PATTERN
= EXISTING
= NEW
SURFACE PATTERN
PHASE LEGEND
2024 All Rights ReservedC
NOT FOR
CONSTRUCTION
2/28/2025 11:03:24 AM
A3.1 ELEVATIONS
GASKIN RESIDENCE
HRB
REVIEW
510 CRAVEN STREET
2.28.2025
1/4" = 1'-0"1 SOUTH ELEVATION
1/4" = 1'-0"2 WEST ELEVATION
EXISTIING
BUILDING
1/4" = 1'-0"3 NORTH ELEVATION GARDEN SHED
NEW GARDEN SHED
PAINT TO MATCH EXISTING FOUNDATION
NEW ROOF RETURN TO
MATCH EXISTING
EXISTING ROOF RETURN
ROOF CRICKET
= EXISTING
= NEW
CUT PATTERN
= EXISTING
= NEW
SURFACE PATTERN
PHASE LEGEND
2024 All Rights ReservedC
NOT FOR
CONSTRUCTION
2/28/2025 11:03:25 AM
A3.2 3D VIEWS
GASKIN RESIDENCE
HRB
REVIEW
510 CRAVEN STREET
2.28.2025
SEE TYPICAL WALL SECTION (4/A4.1)
AND DETAIL SHEETS FOR DETAILS.
1 NORTHEAST 3D VIEW
2 SOUTHEAST 3D VIEW
EXISTING CASEMENT WINDOWS
NEW CASEMENT WINDOWS TO MATCH EXISTING
EXISTING CASED
OPENING AND
TRANSOM 65" TV
NEW STAIR
NEW DECKING
ON EXISTING FLOOR
FRAMING
ORIGINAL WALL TO REMAIN
NEW WOOD DOOR AND TRANSOM
1
A4.1
2x4 TO RUN ALONG STRINGERS
STRINGER
1x SKIRT AND RISER
(PAINTED)
MITER PERIMETER
LANDING AS SPECIFIED
FOR 15" TREADS: 5/4x6 W/ 5/4X6 PERIMETER, SPACE BOARDS 1/4"
SEE STRUCTURAL
DWGS FOR FOOTING
SIZE & DETAILS
2x4 TO SPAN BTWN
STRINGERS - NOTCH
INTO STRINGERS
ALL WOOD TO BE KDAT-[ TREADS TO BE PAINTED TO MATCH
PORCH DECKING AND RISERS-SKIRT TRIM COLOR
EXISTING 7" SQ. POST
ALUM. FACTORY
FINISHED FLASHING
COLOR TO MATCH
TRIM CUT INTO POST
1/4" SEAL WITH ZIP
LIQUID FLASHING
BELOW FLASHING
1/2" ZIP SYSTEM
SHEATHING ON 2X4
FRAMING WITH R-19
INSULATION
BENJAMIN OBDYKE
SLICKER MAX
RAINSCREEN 6MM
INSTALL 2X (FLOOR
FRAMING DEPTH
) PERPENDICULAR
BLOCKING AT 16" O.C.
UNDER NEW WALL.
INSTALL COVER TRIM
AFTER ROLLER SHADE
PAINTED 1X WOOD
SHADE BOX
CYPRESS 1X6 T&G
CEILING
EXISTING PORCH FLOOR,
STUCCO FOUNDATION TO
REMAIN
R-19 CLOSED CELL
SPRAY INSULATION
EXISTING ROOF, COLUMNS,
FASCAI AND BEAM TO REMAIN
NEW SOLAR PANELS
NEW CASEMENT WINDOW TO
MATCH EXISTING
NEW AWNING WINDOW
MATCH EXISTING
NEW 2X4
BASEBOARD AND TRIM
TO MATCH EXISTING
2X FRAMING TO ALIGN FLOOR
WITH EXISTING
3/4" ADVANTECH FLOOR SHEATHING
AND PINE FLOOR TO MATCH EXISTING
NEW ROOF TO MATCH EXISTING ON
3/4" ROOF SHEATHING, AND 1X6
PAINTED PINE
4X4 KDAT ROOF RAFTERS
BEAM SEE ELEVATION
ALUM. FLASHING
MATCH ROOF
FIXED LOUVER TO
MATCH EXISTING
PAINT SAME COLOR
8" CMU WALL WITH STUCCO
FINISH TO MATCH EXISTING
8"X16" CONCRETE FOOTING
W/ 2 #5 REINFOR. BARS
CONTINUOUS AND 1
VERTICAL EVERY CORNER
AND 32" O.C. MAX.
EXISTING SIDING
EXISTING BAND
EXISTING LATTICE 4" CONC. SLAB
2024 All Rights ReservedC
NOT FOR
CONSTRUCTION
2/28/2025 11:03:26 AM
A4.1 BUILDING AND WALL SECTIONS
GASKIN RESIDENCE
HRB
REVIEW
510 CRAVEN STREET
2.28.2025
1/2" = 1'-0"2 FAMILY ROOM EAST WALL 1/2" = 1'-0"3 SECTION AT EXISTING PORCH
1/2" = 1'-0"4 EXTERIOR WOOD STAIR
1" = 1'-0"1 SECTION AT NEW WINDOWS
3/4" = 1'-0"5 SECTION AT GARDEN SHED
Darlana Small Tall Bracketed Wall Lantern
Designer: Chapman & Myers
Item # CHO 2086BZ
TEAR SHEET
Height: 21.25"
Width: 7.5"
Extension: 9.75"
Backplate: 4" x 13" Rectangle
Finishes: BZ
Glass Options: CG
Socket: 2 - E12 Candelabra
Wattage: 2 - 60 C11
Weight: 15 Pounds
Note: Requires Smaller Outlet Box
©EFC DESIGNS
Fixture "B"
Image File Name: F523L-WHF.jpg
Aluma Wet - LED 52" Ceiling Fan
Item #: F523L-WHF
UPC Code: 706411065262
Product Family Name: Aluma
Finish: Flat White
Category: EXTERIOR FAN
Category Type: Ceiling Fan
Certification: E75795
Patents:
Notes:
LED
Wet Location
UL Listed
MEASUREMENTS
Blade Finish:
Blade Material: ABS
Blade Sweep: 52"
No. of Blades: 4
Blade Pitch: 12
Reversible Blades: NO
Slope: YES
Hanging Weight: 19.18
Downrod 1: 6
Downrod 1 Outside Dia: .75
Downroad 2:
Downrod 2 Outside Dia:
Ceiling to Lowest Point: (Dim A): 16.25
Ceiling to Blade (Dim B): 12.91
Lead Wire: 80
Power: AC
Motor Size: AC 153 X 20 MM
Low Low/Med. Medium Med/High High
RPM 71 154
Amps 0.216 0.436
Watts 13.16 50.02
CFM 1861.0 3864.0
CFM/Watts 141.41 77.25
LAMPING
No. of Bulbs: 1
Max Bulb Wattage: 20
Light Type: Z04 LED
Light Kit Optional: NO
Socket: Y06 LED MODULE
Integrated Light Kit: YES
Dimmable: YES
Ballast:
Rated Life Hours: 20000
Uplight: NO
Bulb/LED Included: YES
Color Temp.: 3000
CRI: 92
Initial Lumens: 1652.25
Delivered Lumens: 905.2
GLASS
Description: ETCHED OPAL
Material: GLASS
Part No.:
Quantity: 1
Width: 9.25
Height: 2.75
Length: 9.25
CONTROLS
Pull Chain Control: NO
Works with Remote Control: YES
Works with Wall Control: YES
Reversible: YES
Included Remote Control: RCS213
Included Wall Control:
Smart Control: NO
Compatible Remote Control(s):
Compatible Wall Control(s): WCS213
Integrated Smart Control:
Compatible Smart Control: BD-1000
SHIPPING
Carton Width: 11.88
Carton Height: 10.25
Carton Length: 24.0
Carton Weight: 22.02
Carton Cubic Feet: 1.691
Small Package Shippable: YES
Master Pack Width:
Master Pack Height:
Master Pack Length:
Master Pack Weight:
Master Cubic Feet:
Multi-Pack: 1
Master Pack: 1
WARNING: Handling this productcan expose you to chemicals including lead, which is known to the State ofCalifornia to
cause cancer and birth defects or other reproductive harm. Wash hands with soap and water after installing, handling,
cleaning or otherwise touching this product. For more information go to: www.P65Warnings.ca.gov.
For additional information, please contactCustomer Care: 1-800-221-7977 | Productdepicted on this specsheetis
protected byUnited States Federal and/or State laws including US Patent, Trademark and/or Copyrightand unfair
competition laws. Unauthorized reproduction or use carries severe legal penalties.
Rev 01.10.2024 01:45 PM
Fixture "E"
Fixture Type:
Catalog Number:
Project:
Location:
WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program. DEC 2021
waclighting.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
Model: WL-LED100
LEDme® Step Light
FEATURES
• Solid diecast brass, corrosion resistant aluminum alloy,
or cast stainless steel construction
• Direct wiring, no driver needed
•
• 54,000 hour rated life
• Balanced lighting, free of shadows with minimum glare
• IP66 rated, Protected against high-pressure water jets
•
• 5 year WAC Lighting product warranty
ORDER NUMBER
120V Model # Light Color Finish
WL-LED100 120V
C
AM
RD
BL
White
Amber
Red
Blue
3000K
27 Warm 2700K
610nm
640nm
450nm
BK
BN*
BZ
GH
SS
WT
Black on Aluminum
Brushed Nickel on Aluminum
Bronze on Aluminum
Graphite on Aluminum
Stainless Steel
White on Aluminum
WL-LED100 120V C
AM
White
Amber
3000K
27 Warm 2700K
610nm
BBR Bronze on brass
*Brushed Nickel Finish is for interior use only
277V Model # Light Color Finish
WL-LED100F 277V
C
AM
RD
BL
White
Amber
Red
Blue
3000K
610nm
640nm
450nm
BK
BN*
BZ
GH
SS
WT
Black on Aluminum
Brushed Nickel on Aluminum
Bronze on Aluminum
Graphite on Aluminum
Stainless Steel
White on Aluminum
– –
Example: WL-LED100F-BL-SS
PRODUCT DESCRIPTION
Horizontal rectangle LEDme® Step Light. Designed for safety and
style on stairways, patios, decks, balcony areas, walkways and
building perimeters.
indoor and outdoor lighting solutions. Creates an attractive,
romantic impression at night.
5"
3"
2a"
18"
front
12"
18"
x"
2"
side
1d"
22"
back
SPECIFICA TIONS
Construction: Die-cast aluminum or 316 marine grade cast stainless steel
Power: Direct wiring, no remote driver needed. Input voltage:
120V or 277VAC 50/60Hz
Light Source: 2700K or 3000K CCT Samsung HV-AC High Power LED, CRI: 90
Optional color lenses. Total power consumption of 3.5W
Mounting: Fits into 2” × 4” J-Box with minimum inside dimensions of
3"L × 2"W × 2"H
Includes bracket for J-Box mount.
Dimming:
Dim to 10% with electronic low voltage (ELV) dimmer
Approved dimmers: Lutron Nova-T NTELV-300 & NTELV-600,
Lutron Vietri VTELV-600, Lutron Diva DVELV-300P ,
Lutron Skylark SELV-300P , Lutron Maestro MAELV-600
Standards: IP66, UL & cUL Listed for wet locations,
Title 24 JA8-2016 Compliant.
2"NPT threaded hole
BREAKING THE 20 % EFFICIENCY BARRIER
Q.ANTUM DUO Z Technology with zero gap cell layout
boosts module efficiency up to 21.4 %.
THE MOST THOROUGH TESTING PROGRAMME IN THE INDUSTRY
Q CELLS is the first solar module manufacturer to pass the most comprehen-
sive quality programme in the industry: The new “Quality Controlled PV” o f
the independent certification institute TÜV Rheinland.
INNOVATIVE ALL-WEATHER TECHNOLOGY
Optimal yields, whatever the weather with excellent
low-light and temperature behavior.
ENDURING HIGH PERFORMANCE
Long-term yield security with Anti LID Technology, Anti PID
Technology1, Hot-Spot Protect and Traceable Quality Tra.Q™.
EXTREME WEATHER RATING
High-tech aluminum alloy frame, certified for
high snow (5400 Pa) and wind loads (4000 Pa).
A RELIABLE INVESTMENT
Inclusive 12-year product warranty and 25-year
linear performance warranty 2.
1 APT test conditions according to IEC / TS 62804-1:2015, method A (−1500 V, 96 h)
2 See data sheet on rear for further information.
THE IDEAL SOLUTION FOR:
Rooftop arrays on
residential buildings
Q.PEAK DUO ML-G10.a
395-415
ENDURING HIGH
PERFORMANCE
76.4 in
1940 mm
43.3 in
1100 mm
48.0 in
1220 mm
1656 lbs
751 kg
24 24 32
α [% / K] +0.04 β [% / K] −0.27
γ [% / K] −0.34 NMOT [°F] 109 ± 5.4 (43 ± 3 °C)
Hanwha Q CELLS America Inc.
400 Spectrum Center Drive, Suite 1400, Irvine, CA 92618, USA |
TEL +1 949 748 59 96 | EMAIL inquiry@us.q-cells.com | WEB www.q-cells.us
[V] 1000 (IEC) / 1000 (UL) Class II
[A DC] 20 TYPE 2
[lbs/ft 2] 75 (3600 Pa) / 55 (2660 Pa) −40 °F up to +185 °F
(−40 °C up to +85 °C)[lbs/ft 2] 113 (5400 Pa) / 84 (4000 Pa)
3 See Installation Manual
395 400 405 410 415
[W] 395 400 405 410 415
[A] 11.13 11.16 11.19 11.22 11.26
[V] 45.03 45.06 45.09 45.13 45.16
[A] 10.58 10.64 10.70 10.76 10.82
[V] 37.32 37.59 37.85 38.11 38.37
[%] ≥ 20.1 ≥ 20.4 ≥ 20.6 ≥ 20.9 ≥ 21.1
[W] 296.4 300.1 303.9 307.6 311.4
[A] 8.97 8.99 9.02 9.04 9.07
[V] 42.46 42.49 42.52 42.56 42.59
[A] 8.33 8.38 8.43 8.48 8.53
[V] 35.59 35.82 36.04 36.27 36.49
53'
40' HC
Certified
UL 61730
MECHANICAL SPECIFICATION
Format 74.0 in × 41.1 in × 1.26 in (including frame)
(1879 mm × 1045 mm × 32 mm)
Weight 48.5 lbs (22.0 kg)
Front Cover 0.13 in (3.2 mm) thermally pre-stressed glass with
anti-reflection technology
Back Cover Composite film
Frame Black anodized aluminum
Cell 6 × 22 monocrystalline Q.ANTUM solar half cells
Junction Box 2.09-3.98 in × 1.26-2.36 in × 0.59-0.71 in
(53-101 mm × 32-60 mm × 15-18 mm), IP67, with bypass diodes
Cable 4 mm² Solar cable; (+) ≥ 49.2 in (1250 mm), (−) ≥ 49.2 in (1250 mm)
Connector Stäubli MC4, Hanwha Q CELLS HQC4; IP68
Note: Installation instructions must be followed. See the installation and o perating manual or contact our technical service department for furthe r information on approved installation and use of
this product.
Specifications subject to technical changes © Q CELLS Q.PEAK DUO ML-G10.a_395-415_2021-05_Rev01_NA
ELECTRICAL CHARACTERISTICS
POWER CLASS
MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS, STC 1 (POWER TOLERANCE +5 W / −0 W)
Minimum
Power at MPP 1 PMPP
Short Circuit Current 1 ISC
Open Circuit Voltage 1 VOC
Current at MPP IMPP
Voltage at MPP VMPP
Efficiency 1 η
MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS, NMOT 2
Minimum
Power at MPP PMPP
Short Circuit Current ISC
Open Circuit Voltage VOC
Current at MPP IMPP
Voltage at MPP VMPP
1Measurement tolerances P MPP ± 3 %; ISC; VOC ± 5 % at STC: 1000 W/m2, 25 ± 2 °C, AM 1.5 according to IEC 60904-3 • 2800 W/m², NMOT, spectrum AM 1.5
Q CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE
At least 98 % of nominal power during
first year. Thereafter max. 0.5 %
degradation per year. At least 93.5 %
of nominal power up to 10 years. At
least 86 % of nominal power up to
25 years.
All data within measurement toleranc -
es. Full warranties in accordance with
the warranty terms of the Q CELLS
sales organisation of your respective
country.
Typical module performance under low irradiance conditions in
comparison to STC conditions (25 °C, 1000 W/m²)
TEMPERATURE COEFFICIENTS
Temperature Coefficient of I SC Temperature Coefficient of V OC
Temperature Coefficient of P MPP Nominal Module Operating Temperature
PROPERTIES FOR SYSTEM DESIGN
Maximum System Voltage V SYS PV module classification
Maximum Series Fuse Rating Fire Rating based on ANSI / UL 61730
Max. Design Load, Push / Pull 3 Permitted Module Temperature
on Continuous DutyMax. Test Load, Push / Pull 3
NA
DETAIL A 0.63" (16 mm)
0.33" (8.5 mm)0.96" (24.5 mm)
42.8" (1088 mm)
74.0" (1879 mm)
4 × Mounting slots (DETAIL A)
Frame
41.1" (1045 mm)
39.2" (996 mm)
1.26" (32 mm)
8 × Drainage holes
15.6“ (395.5 mm)
4 × Grounding points ø 0.18" (4.5 mm)
Label
≥ 49.2" (1250 mm)
≥ 49.2" (1250 mm)
RELATIVE EFFICIENCY
COMPARED TO NOMINAL POWER [%]
YEARS
Q CELLS
Industry standard for linear warranties*
*Standard terms of guarantee for the 10 PV companies
with the highest production capacity in 2014 (as at: September 2014)
100
95
90
85
80
15 5 25 20 0 10
98
86
200 400 600 800 1000
110
100
90
80
RELATIVE EFFICIENCY [%]
IRRADIANCE [W/m²]
QUALIFICATIONS AND CERTIFICATES PACKAGING INFORMATION
UL 61730, CE-compliant,
Quality Controlled PV - TÜV Rheinland,
IEC 61215:2016, IEC 61730:2016,
U.S. Patent No. 9,893,215 (solar cells),
QCPV Certification ongoing.
Horizontal
packaging
pallets pallets modules
STAFF REPORT: Historic District Review Board (HRB)
510 CRAVEN STREET – Approval
DATE: March 12, 2025
Background: The applicant has attended 2 rounds of HTRC meetings and is ready for a meeting with the
Historic District Review Board (HRB) to present a partial enclosure of the rear porch of the contributing
ca. 1885 house at 510 Craven Street.
Tree Removal Proposed:
No trees are proposed to be removed.
GENERAL INFORMATION
Applicant: Michael Frederick, Frederick + Frederick Architects
Site Location/Address: 510 Craven Street; R120 004 000 0890 0000
Applicant's Request: Applicant is proposing a partial enclosure of the rear porch.
Current Zoning: T4-HN
Contributing/Neighborhood Contributing Structure (ca. 1885) as per Nat’l Register of Historic Places
Flood Zone/Base Flood Flood Zone: Shaded X/AE
Elevation: ~8’-9’
Existing Trees 1 Live Oak at front of property (unaffected by plans)
ZONING DISTRICT INFORMATION
T4-HN
Lot Width at Setback: 40 ft min.
60 ft min. in The Point
Max Lot Coverage: 55% of lot area
Min. Frontage Build Out 75% max
Front Setback Average Prevailing Setback on Block
Side Setback 6 ft min.
10 ft min. in The Point
5 ft min. corner/alley
Rear Setback 15 ft min.
Building Height: 3 stories max
SURROUNDING ZONING, LAND USE AND REQUIRED BUFFERS
Adjacent Zoning Adjacent Land Uses Setbacks for Adjacent Zoning
/Buffer required if rezoned
North: T4-HN Single Family Residential N/A
South: T4-HN Single Family Residential N/A
East: T4-HN Single Family Residential N/A
West: T4-HN Single Family Residential N/A
2
Surrounding Area:
This property is in The Point neighborhood. The buildings on the block and surrounding area are made
up of historic structures. Most of the buildings are two stories high, with a few one-story buildings
throughout. This specific single family residential dwelling is an 1885 historic home, and as such is a
contributing resource on the National Register of Historic Places for the Beaufort Historic District.
Determination of adequate historic integrity for New Construction, Infill, Additions and
Demolition:
As per the Beaufort Preservation Manual (Chapter 5) and the Beaufort Development Code (Section 4.7),
new infill construction as well as major renovations to existing structures must be conducted in
consideration to the architectural fabric of the community. This can be successfully achieved by adhering
to the following principles: 1. Location, 2. Design, 3. Setting, 4. Materials, 5. Workmanship, 6. Feeling
and 7. Association. As per these guidelines, the following staff analysis determines the integrity of this
major renovation request.
4.7.2 Integrity Guidelines (as per the
Beaufort Development Code)
Rationale
Present
(yes/no)
Staff Analysis of Rationale
1. Location: This is the relationship
between the property and its historical
context.
Yes ✓ This single-family residential dwelling
from 1885 can be historically tied to
many similar houses in The Point
neighborhood.
2. Design: This is the combination of
elements that create the feeling of a district
or structure. These elements include
building patterns, streetscapes, site
elements, building size, mass and scale,
spatial relationships, and specific
architectural elements and details.
Yes ✓ There proposed design elements are
compatible and keep with the historic
theme of the neighborhood.
3. Setting: This is the physical environment
of a property and should be evaluated on
its context as well as on the historical role
the property has played and continues to
play. Important features include
topography, vegetation, man-made
Yes ✓ The surrounding properties are mainly
residential dwellings of similar size
(mostly 2-story contributing
structures). This residential retrofit
complies with its surroundings in use
3
features, and relationships between
existing structures and their surroundings.
and scale.
4. Materials: These are the physical
elements that make up a property or
district.
Yes
✓ The proposed materials and design
elements comply with the visual texture
of The Point neighborhood.
5. Workmanship: This is the physical
evidence of the crafts of a particular culture
or time period. This particularly applies to
rehabilitation projects, but for new infill
projects, workmanship of surrounding
structures should be considered and
respected. Retaining the details of the
original craft and craftsman (i.e., wood,
masonry, tabby etc.) of the original building
ensures the historic fabric is retained and
serves as an important component of the
integrity and the patina of age of individual
structures and the district as a whole.
Yes ✓ Staff is supportive of the proposed
changes to the enclosed porch as this
keeps the existing historic rear door and
window, and only affects the area that
was already altered in a previous
addition.
6. Feeling: This is the property's
expression of the aesthetic or historic sense
of a particular period of time. This
particularly applies to rehabilitation
projects, but for new infill projects, the
feeling of surrounding structures should be
considered and respected.
Yes
✓ The proposed design features
aesthetically represent the historic
period of the building, and helps it
maintain the historic feeling of the
neighborhood.
7. Association: This is the direct link
between an important historic event or
person and a property. This particularly
applies to rehabilitation projects, but for
new infill projects, association of particular
sites and neighborhoods considered.
N/A ✓ Staff has not found any relevant history
or persons directly linked to this
specific property.
Synopsis of staff comments from last Historic District Technical Review Committee (HTRC)
Meeting on February 05, 2025:
• Planning and zoning:
➢ Contributing Structure (ca. 1885)
➢ Zoned T4-HN
4
• Architecture:
➢ Staff is supportive of the proposed changes to the enclosed porch as this keeps the existing
historic rear door and window and only affects the area that was already altered in a previous
addition
➢ Provide detailed drawings of new window/doors, eave, column, etc.
FINDINGS AND RECOMMENDATIONS
Staff Recommendation:
Staff recommends Final Approval of the proposed partial porch enclosure as submitted, in that it
satisfies the intent of the Beaufort Preservation Manual and requirements of the Beaufort Code,
with the following conditions:
1) Staff supports the proposal to enclose part of the existing porch on the south façade.
2) Staff is in support of the solar panels on the one -story portion of the house as this area is
least visible from New Street and Craven Street.
3) Staff recommends moving the triple -ganged windows on the New Street façade slightly to
the north and away from the southernmost column – these windows are not symmetrical
between the columns, creating a wider length of siding on the left side of the windows,
while the right side seams to crowd against the southern column.
4) Staff is in support of the proposed changes to the garden shed.
5) Staff supports all lighting and fan selections.
MEMO
HDRB Joint Session
SCOTT MARSHALL
City Manager
CITY OF BEAUFORT
Community Development Department
1911 BOUNDARY STREET
BEAUFORT, SC 29902
(843) 525-7011
FAX (843) 986-5606
CURT FREESE
Community Development
Director
Date: March 12, 2025
From: Curt Freese, Community Development Director
To: HDRB
ISSUE: Joint Meeting PC
BACKGROUND:
There was discussion at the 2025 Strategic Planning session about proposed changes to Chapter 9 of
the Development Code, related to the HDRB, such as changes to COA’s, Demolitions, findings, etc. The
Development Code revisions were approved last June by the PC but have yet to move forward to a
vote with the City Council. Both the chairman of the HDRB and PC agreed a joint meeting to discuss
the recommended PC changes, with the opportunity for the HDRB to make recommendations based on
their practical experience and knowledge of the proposed Chapter 9 recommendations.
Staff proposes utilizing the April 15
th PC meeting at 5:00 pm for the joint meeting.
MEMO
HDRB Tour
SCOTT MARSHALL
City Manager
CITY OF BEAUFORT
Community Development Department
1911 BOUNDARY STREET
BEAUFORT, SC 29902
(843) 525-7011
FAX (843) 986-5606
CURT FREESE
Community Development
Director
Date: March 12, 2025
From: Curt Freese, Community Development Director
To: HDRB
ISSUE: Spring Tour
BACKGROUND:
Staff would like to propose a spring walking tour. Please find a proposed itinerary below, based on the
comments at the February HDRB meeting.
9:00 am: Meet at 500 CARTERET STREET (Parking pass will be provided). Staff will organize a tour.
9:00-9:30 am: 903-905 King Street, New Construction
9:30-11:00 Tour of Stablization Properties: 810/812 Congress, 1305 Congress, 1008 West Street, 1408
Greene St, 710 Charles, 809 Charles, 1108 Washington, 908 Duke St., 910 Harrington Street, 1504
Prince.
11:00-11:45: 1401 Duke Street Rehab
11:45-12:30: Cuthbert House (porch materials), 1103 Bay Street
12:30-2: Lunch
POSSIBLE DATES:
FRIDAY MARCH 28
FRIDAY APRIL 4
FRIDAY APRIL 11