RecordWell Data

_11052026-603

City of North Myrtle Beach · Horry County · meeting of Nov 5, 2026 · Minutes

Open the original document More from City of North Myrtle Beach

Text

Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.

TRC Minutes 11.05.26 Page 1 of 6 TECHNICAL REVIEW COMMITTEE MINUTES Thursday, November 5, 2026 – 10:00 A.M. Training Room/Zoom NEW APPLICATIONS CR-26-55: Courtesy Review – Subdivision Discussion at 4825 Little River Neck Road Attending Customer Representatives: Thomas Winstead, Applicant Staff Comments Public Works: 1. Provide conceptual plan for review. 2. Public water available. 3. Public sewer available with extension by developer. Evaluate extension of existing gravity sewer or utilize a new pump station/force main. 4. If using a cul-de-sac, minimum hard surface diameter is 96 feet (emergency vehicle requirement). Refer to Street Planning Manual for approved street standards and utility placements. 5. SCDOT encroachment permit required for any work within the Little River Neck Rd. R/W. 6. Must meet stormwater design standards. 7. Additional comments reserved. Zoning: 8. 10,000 square foot minimum lot size. 9. 80' minimum lot width. 10. Lots on cul-de-sacs, lot width is reduced by 33%, 53.6' width at 25' setback line. 11. Possible three lots with cul-de-sac. 12. Right of way would eat up enough square footage to make 4 lots unfeasible due to 10,000 lot minimum. 13. Need dimensional subdivision drawing depicting proposed lots and/or proposed right-of-way and lots. Building: No comments Fire: 14. All portions of the building must be within required fire access distance. Revise the plan to demonstrate compliance. 15. Provide a fire apparatus turning exhibit to confirm that emergency vehicles can access all areas of the site. 16. Fire hydrants shall be spaced in accordance with City standards (maximum spacing measured along the roadway). Provide a dimensioned exhibit demonstrating compliance. Planning: 17. If the proposed subdivision involves the creation of a new street/right-of-way or extension of utilities, it will be classified as a major subdivision and will require submission of a sketch plan, preliminary plat, and final plat for review and approval by the Planning Commission. If the proposed lots front on an existing street and do not involve a new street or utility extensions, the subdivision may qualify as a minor subdivision and be eligible for staff review and approval in accordance with Section 20-30 of the Land Development Regulations. TRC Minutes 11.05.26 Page 2 of 6 CR-26-56: Courtesy Review – Addition at Our Lady Star of the Sea Catholic Church at 1108 8th Avenue South Attending Customer Representatives: Greg Atkinson, Applicant Staff Comments Public Works: 1. Over 5- bedrooms. Additional impact fees will be assessed during the building permit application review process. 2. Per the city’s BMP design manual – “If the redevelopment project area is less than fifty (50) percent of the existing developed condition area and includes the addition of impervious area, then all standards of the SWDM apply to the additional impervious area.” Provide storage for the runoff from the additional impervious areas. Recommend perc pipe with yard drains with an overflow catch basin. Storage volume to accommodate the 100-year, 24-hour storm event. 3. Confirm existing meter size is adequate. Add SCDES approved backflow device. Zoning: 4. Site plan needed for 6 bedroom/sleeping area home. 5. Off-site parking document needs recorded. 6. Noncontiguous, off-street parking: The owner of a parcel of land may provide the required automobile storage and parking spaces on lands on which the use is situated and on levels which are not contiguous to the lands on which the use is situated, provided that all of the conditions set forth herein are satisfied. All residential uses in all zoning districts (except overlay zones) and commercial uses in the RC (Resort Commercial) district shall have a minimum of seventy- five (75) percent of all required parking spaces located on lands on which the use is situated and a maximum of twenty-five (25) percent of such spaces may be located off-site where the farthest parking space is located no farther than three hundred (300) feet from the principal sit. The owner shall impose restrictions on such non-contiguous parking lands by a recorded declaration which shall require written consent of the city to release such lands from restriction. Such recorded declaration shall run with the land and shall provide that so long as the use exists, the lands shall be utilized exclusively as a parking area serving the use except as follows: No non-contiguous parking lands shall be located in any zone other than one (1) for which the use is permitted. Paved sidewalks, as per City of North Myrtle Beach specifications, from the noncontiguous lot to the principal development shall be provided at the owner's expense. The noncontiguous parking lands shall be clearly marked by appropriate signage indicating that such lands are devoted to parking area serving the use and such signage shall be maintained in good state of repair. The non-contiguous parking lands shall be physically improved, landscaped, and surfaced in the same manner as the parking area located on the lands on which the use is situated. All surface water must be retained on-site or drained into public storm water drainage ways in accordance with accepted engineering practices as approved by the city engineer. TRC Minutes 11.05.26 Page 3 of 6 Each parking space shall be unobstructed and shall be so arranged that any vehicle may be moved into and out of each space without moving any other vehicle. No certificates of occupancy shall be issued for any units until the required number of parking spaces, with ingress and egress, are fully constructed for the number of units for which certificates of occupancy are requested. In the event any of the required parking spaces for units for which certificates of occupancy are requested are provided on non-contiguous parking lands, such lands shall be fully constructed and restricted by deed in accordance with all of the standards of this chapter before the certificates of occupancy shall be issued. Off-site parking areas shall be cleared and graded within ninety (90) days of issuance of a building permit. The off-site parking area shall then be reserved for employee parking until the project receives a certificate of occupancy or is released at the discretion of the chief building inspector. All parking on noncontiguous lots shall be in accordance with section 23-42, parking design criteria. Building: 7. Submit required architectural and engineered plans when applying for permits. Fire: No comments Planning: No comments TRC-26-39: Site-Specific Development Plan –820 Bently Lane Attending Customer Representatives: No representative Staff Comments Public Works: 1. A grading and drainage plan is required for this site since the proposed driveway crosses a significant wetland and drainageway that conveys runoff from upstream properties and the existing retention pond. Appropriately sized culvert(s) must be designed and installed beneath the proposed driveway to safely convey anticipated stormwater flows and prevent adverse impacts to both upstream properties and to the subject property. Note twin 48” RCPs are located just downstream within this drainage way crossing Inlet View Drive. 2. Provide storm drainage report. A licensed professional engineer shall evaluate the contributing drainage area, calculate the anticipated stormwater flows crossing the property, and determine the appropriate size and configuration of the required culvert(s). 3. Provide ACOE wetland impact permit or letter from the ACOE stating no permit is required. All wetland impacts must be evaluated by the Army Corps of Engineers. Current wetland delineation/survey/JD determination may be required by the Corps. 4. The drainage calculations and grading & drainage plan must be signed and sealed by South Carolina registered professional engineer. 5. Provide erosion and sediment control plan. Provide double row silt fence along wetland areas to remain. 6. No water and sewer taps were installed for this parcel during original construction. Show location of new water and sewer taps. 7. Provide retaining wall structural details. TRC Minutes 11.05.26 Page 4 of 6 8. Additional comments may be forthcoming pending further review or receipt of revised documents. Zoning: 9. Please overlay trees on a clean version of the plot plan so we can see proposed removals. Building: No comments Fire: No comments Planning: No comments TRC-26-41: Site-Specific Development Plan – Six Sleeping Area Home at 500 South Ocean Boulevard Attending Customer Representatives: Mark Donovant, Engineer Staff Comments Public Works: 1. Provide stormwater/pipe sizing calculations. 2. Must meet 25 year – 24-hour storm event if there is a tie-in to an existing storm system. 3. Must be able to hold the 100 year – 24-hour storm event if there is no tie-in to an existing storm system. 4. Address sheet flow to DOT right-of-way. Capture sheet flow with additional perc pipe as needed. Provide perc pipe along western property line within the building setback area. Contain runoff on-site; eliminate common lot line swale. 5. Erosion control plan needed. 6. City to make taps and install new water and sewer services to the property line. Revise note accordingly. 7. Provide SCDOT encroachment for driveway on S. Ocean Blvd and storm drain tie-in on 5th Ave S. (required prior to sign-off on construction plans). Zoning: No comments Building: 8. Must meet all current City flood zone ordinances including the 1ft freeboard requirement. Fire: No comments Planning: 9. Provide sidewalk along Ocean Blvd. right-of-way. TRC-26-40: Site-Specific Development Plan – Six Sleeping Area Home at 500 South Ocean Boulevard Attending Customer Representatives: Mark Donovant, Engineer Staff Comments Public Works: 1. Provide stormwater/pipe sizing calculations. 2. Must meet 25 year – 24-hour storm event if there is a tie-in to an existing storm system. 3. Must be able to hold the 100 year – 24-hour storm event if there is no tie-in to an existing storm system. 4. Address sheet flow to DOT right-of-way. Capture sheet flow with additional perc pipe as needed. Provide perc pipe along western property line within the building setback area. Contain runoff on-site; eliminate common lot line swale. 5. Erosion control plan needed. TRC Minutes 11.05.26 Page 5 of 6 6. City to make taps and install new water and sewer services to the property line. Revise note accordingly. 7. Provide SCDOT encroachment for driveway on S. Ocean Blvd and storm drain tie-in on 5th Ave S. (required prior to sign-off on construction plans). Zoning: No comments Building: 8. Must meet all current City flood zone ordinances including the 1ft freeboard requirement. Fire: No comments Planning: 9. Provide sidewalk along Ocean Blvd. right-of-way. TRC-26-37: Site-Specific Development Plan – Eight Sleeping Area Single-Family Home at 2503 Holly Drive Attending Customer Representatives: Tucker Davis, Applicant Staff Comments Public Works: No comments Zoning: 1. No parking space shall have direct access to a street, and no vehicle shall extend into a public right-of-way. Each parking space shall be unobstructed and shall be so arranged that any vehicle may be moved into and out of such space without moving another vehicle. 2. Any room or space that provides privacy and separation from common living areas and could function as a sleeping space. Rooms labeled as offices, dens, bonus rooms, or similar shall be considered sleeping areas where the design includes features consistent with sleeping use, such as: Enclosure with walls and a door or defined separation or layout and dimensions consistent with habitable space. 3. Parking shall be located on the property. 4. Reducing to 7 bedrooms/sleeping areas. New parking requirement of 4 spaces is approvable as depicted. Building: No comments Fire: 5. If this addition is per the IRC, no specific fire code requirements are needed. Planning: No comments Z-26-20: Major Planned Development District Amendment – Vehicle Storage and Clubhouse at 8417 Water Tower Road Attending Customer Representatives: Ed McDowell, Owner Staff Comments Public Works: No comments Zoning: No comments Building: No comments Fire: No comments Planning: No comments TRC Minutes 11.05.26 Page 6 of 6 BLD-26-5263: Building Permit – Discussion on Barefoot Resort Outfall #2 Repairs Attending Customer Representatives: Edward Porcher, Engineer and HOA Members Staff Comments Public Works: No comments Zoning: No comments Building: No comments Fire: No comments Planning: No comments BLD-26-5343: Building Permit – Discussion for 410 Hillside Drive South Attending Customer Representatives: No representative Staff Comments Public Works: No comments Zoning: No comments Building: No comments Fire: No comments Planning: No comments

Source: City of North Myrtle Beach website. First collected Nov 14, 2026.