Nov Packet (1)
City of Anderson · Anderson County · meeting of Nov 17, 2026 · Agenda packets
Open the original document More from City of Anderson
Text
Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.
401 South Main St. • Anderson, SC 29624 • phone: 864-231-2200 • fax: 864-231-7854
Board of Architectural Review
AGENDA
City Hall in Council Chambers
Wednesday, November 18, 2026
5:30 pm
I. Addenda to Agenda
II. New Business
• BAR-26-52 523 N Main (sign)
• BAR-26-55 419 Central (color)
• BAR-26-56 106 North Ave (color)
• BAR-26-57 302 E Franklin (alteration)
• BAR-26-58 908 W Whitner (alteration)
• BAR-26-50 407 Watson (alteration)
III. Board Business
IV. Staff Report
V. Adjourn
STAFF REPORT
CITY OF ANDERSON BOARD OF ARCHITECTURAL REVIEW
Application Number: BAR-26-52
Applicant: Kristine Barksdale, ABC Banners N Signs
Property Address: 523 N Main St. (Downtown Historic District)
Zoning of Property: CBD, Central Business District
ANALYSIS
This application is for a new Wall Sign. The proposed sign size, configuration, and placement
comply with the UDO.
When reviewing this application, the Board should focus on the standards set forth in Chapter Eight
of the Design Guidelines for Downtown Anderson – Design Guidelines for Signs. The following
sections apply to this request:
Policy: Design a sign to be in balance with the overall character of the property.
8.1 - Consider the building front as part of an overall sign program.
• Coordinate a sign within the overall façade composition.
8.2 - A sign shall be subordinate to the overall building composition.
• Locate a sign on a building such that it will emphasize design elements of the façade itself.
• Mount a sign to fit within existing architectural features. Use the shape of the sign to
help reinforce the horizontal lines of moldings and transoms seen along the street.
8.4 - A flush-mounted wall sign may be considered.
Policy: A sign should be in character with the material, color and detail of a building.
8.13 - Sign materials should be compatible with that of the building facade.
8.15 - Use colors for the sign that are compatible with those of the building front.
• Also limit the number of colors used on a sign. In general, no more than three colors should
be used.
Staff recommends approval as submitted.
ULPG Pan
08/27/2026
Logan L
1 of 1
DSG Rep:
Pages:
Customer / Contact:
ABC Signs
Company:
CONCEPT
Scale : NTS
QTY 1 - SINGLE SIDED
C-1
C-2
C-3
C-4
C-5
(PRINTED COLORS ARE FOR CONCEPTUAL USE ONLY. ACTUAL
COLORS TO BE CONFIRMED PRIOR TO FABRICATION.)
MPC White MPC to match
Pantone 3015 C MPC to
match Pantone 2006 C MPC
to match Pantone 636 C 3M
3630-127 Intense Blue
Color Specifications:
SIDE VIEW
MOCKUP
89 1/2"
87 1/2"
15 1/8"
5/8"
5"
2 3/8"
24"
1/4” (D) aluminum panel painted white (C-1),
dark blue (C-2), yellow (C-3), and light blue (C-4)
1/4” (D) aluminum panel painted white (C-1)
with blue vinyl graphics (C-5)
1/4” (D) aluminum plate
letters painted dark blue (C-2)
1/4” (D) aluminum plate
letters painted yellow (C-3)
1/4” (D) aluminum plate letters and panels with painted graphics and 1/4” (D) aluminum panel with vinyl graphics
STAFF REPORT
CITY OF ANDERSON BOARD OF ARCHITECTURAL REVIEW
Application Number: BAR-26-55
Applicant: Peyton Beaty
Property Address: 419 Central Ave(North Anderson Historic District)
Zoning of Property: NR, Neighborhood Residential
ANALYSIS
The applicant request approval to paint the front porch of the house brown. It was previously
painted green and has sustained wear over the years.
When reviewing this application, the Board should focus on Chapter 3: Rehabilitation of Historic
Resources of the Design Guidelines. The following sections apply to this request:
3.17 Using the historic color scheme is encouraged.
• If an historic scheme is not to be used, then consider the following:
- Generally, one muted color is used as a background to unify the composition.
- One or two colors are usually used for accent to highlight details and trim.
- A single-color scheme should be used for the entire exterior so upper and lower
floors and subordinate wings of buildings are seen as components of a single
structure.
3.18 Base or background colors should be muted.
• Use the natural colors of the building materials, such as the buff color of limestone, as the
base for developing the overall color scheme.
• Use matte finishes instead of glossy ones.
Staff recommends approval. The proposed brown is a muted color that complies with the Design
Guide and blends with the color of the brick.
STAFF REPORT
CITY OF ANDERSON BOARD OF ARCHITECTURAL REVIEW
Application Number: BAR-26-56
Applicant: Jennifer Trammell
Property Address: 106 North Ave (North Anderson Historic District)
Zoning of Property: NR, Neighborhood Residential
ANALYSIS
The applicant is requesting approval to paint exterior of house. The color scheme is as follows:
1. Lap Siding – SW 7018 Dovetail
2. Brick Foundation – existing to remain
3. Trim – SW 7069 Iron Ore
4. Columns, Railings, Latice – SW 7069 Iron Ore
5. Window and door frame – SW 7069 Iron Ore
6. Doors – SW 7069 Iron Ore
7. Stair Risers – SW 7069 Iron Ore
When reviewing this application, the Board should focus on the standards set forth in Chapter 3 of
the Design Guidelines, Historic Districts in Anderson South Carolina. The following sections apply
to this request:
3.17 Using the historic color scheme is encouraged.
• If an historic scheme is not to be used, then consider the following:
- Generally, one muted color is used as a background to unify the composition.
- One or two colors are usually used for accent to highlight details and trim.
- A single color scheme should be used for the entire exterior so upper and lower
floors and subordinate wings of buildings are seen as components of a single
structure.
• Muted colors can help reduce the perceived scale of a building.
3.18 Base or background colors should be muted.
• Use the natural colors of the building materials, such as the buff color of limestone, as the
base for developing the overall color scheme.
• Use matte finishes instead of glossy ones.
RECOMMENDATION
Staff recommends approval.
STAFF REPORT
CITY OF ANDERSON BOARD OF ARCHITECTURAL REVIEW
Application Number: BAR-26-57
Applicant: Juan Pablo Pineda, JP Builders
Property Address: 302 E Franklin St (Anderson Historic District)
Zoning of Property: MR, Mixed Residential
ANALYSIS
The applicant request approval to make the following exterior renovations, and boundary fence
installation. The proposed horizontal Dutchlap siding was selected to replicate traditional historic
wooden weatherboards while providing modern structural durability and a clean white finish.
Architectural charcoal asphalt shingles provide a traditional shadow-line profile compatible with
historic roof pitches, backed by Class A fire safety. The proposed wood fence utilizes traditional
dog-eared pickets providing a privacy screen that conforms to traditional boundary treatments
within the historic district.
• Cladding – dutchlap horizontal vinyl siding with wood grain texture
o color – white
o exisitng - vinyl siding
• Roof – architectural asphalt shingles
o color – charcoal
o exisitng - asphalt shingles
• Windows – double pane vinyl (no grid)
o color – white
o exisitng - wood with no grid
• Front door – fiberglass 2-panel with 6 lites
o color – black
o existing - does not appear original
• Fence – pressure-treated wood panel with dog-eared picket
o Color – walnut stain
When reviewing this application, the Board should focus on Chapter 3: Rehabilitation of Historic
Resources of the Design Guidelines. The following sections apply to this request:
3.17 Using the historic color scheme is encouraged.
• If an historic scheme is not to be used, then consider the following:
- Generally, one muted color is used as a background to unify the composition.
- One or two colors are usually used for accent to highlight details and trim.
3.18 Base or background colors should be muted.
• Use the natural colors of the building materials, such as the buff color of limestone, as the
base for developing the overall color scheme.
• Use matte finishes instead of glossy ones.
Policy: A fence or site wall should be in character with those used traditionally and relate to the
principal structure on a lot.
5.8 Appropriate materials for fences that can be seen from the public right-of-way are wrought iron
or wood picket.
5.9 A side yard fence should be set back from the primary facade of a house.
Staff recommends approval. Although vinyl siding is used it is replacing vinyl siding already on the
house. The proposed renovation complies with the Design Guide.
the established rhythmic openings and scale of the primary facade.
3. Perimeter Enclosure: The proposed wood fence utilizes traditional dog-eared pickets
and
natural
pressure-treated
lumber,
providing
a
privacy
screen
that
conforms
to
traditional
boundary
treatments
within
the
historic
district.
4. Submittal Checklist & Attachments
● [x] Property Tax Map & Plat Reference: Plat Book 3R, Page 68 (Anderson County
Records)
● [x] Site Plan & Architectural Renderings ("New Look" Exterior Elevation) ● [x] Product Cut Sheets & Material Specifications (Siding, Roofing, Windows,
Doors,
Fencing)
Existing Exterior Property Overview
• Siding: White Vinyl Lap Siding
• Roofing: 3-Tab Asphalt Shingles
• Entryway: Solid Wood Door & Frame
• Windows: Single-Pane Glass with Wood Frames
• Lot & Grounds: Open Lot / No Fence
NEW LOOK:
Siding:
• Profile Type: Dutchlap (Horizontal orientation)
• Product Length: 145 inches (approx. 12 feet)
• Width: 10.2 inches
• Coverage Area: 200 square feet per box/bundle.
• Siding Features: Wood Grain Surface texture
• Color Family: White.
• Color/Finish: White.
• Product Weight (lb.): 90 lb.
• Profiles: Dutchlap.
• Siding Features: Wood Grain Surface.
• Vertical/Horizontal: Horizontal
Roofing:
Coverage Area (sq. ft.) 33.33 sq ft.
Product Length (in.) 39.38 in.
Product Thickness (in.) 2.4 in.
Product Width (in.) 13.25 in.
Color: Family Black.
Color: Finish Charcoal.
Features: Algae Resistant, High Wind Resistant, Stainguard
Protection.
Fire Rating:(UL 790) Class A.
Material: Asphalt.
* Requirements: Attic Ventilation, Underlayment.
* Roofing Product Type: Architectural Shingle.
* Shingle Exposure: 5.625 inches.
* Shingle Type: Architectural Shingle
Windows:
• Exterior Color/Finish Family: White.
• Features: Tilt-In Sash.
• Frame Material: Vinyl.
• Frame Type: Nail Fin.
• Glass Type: Low-E Glass.
• Glazing Type: Double-Pane.
• Grid Pattern: No Grid.
• Hardware Color/Finish Family: White
• Included: Hardware, Screen
• Interior Color/Finish Family: White.
• Number of Locks: 1
Door:
Door Height (in.) 80 in.
Front door.
Door Width (in.) 36 in.
amb Size (in.) 4-9/16".
Nominal Door Height (in.) 80 in.
Nominal Door Width (in.) 36 in.
Rough Opening Height (in.) 82 in.
Rough Opening Width (in.) 38.25 in.
Bore Type: Double Bore.
Color Family: White.
Color/Finish: Black on the outside.
Door Configuration: Single Door.
Door Glass Insulation Dual Pane.
Door Handing: Right-Hand/
Inswing.
Door Style : Traditional
Door Type Exterior Prehung.
Features : Brickmold, Lockset Bore (Double Bore), Weatherstripping.
Finish Type: Primed.
Frame Material: Wood.
Glass Caming Finish: No caming.
Glass Layout: 1/4 Lite
Glass Shape: Rectangle Lite.
Glass Style: Clear Glass.
Hinge Finish: Black
Hinge Type: Ball Bearing.
Material: Fiberglass.
Number of Lites: 6 Lite.
Panel Type: 2 Panel.
Product Weight: (lb.) 110 lb.
FENCE :
Actual panel height: (in.) 72 in.
Actual panel thickness: (in.) 2.25 in
Actual panel width: (in.) 96 in.
Nominal panel height: (ft.) 6 ft.
Nominal panel thickness: (in.) 2.25 in.
Nominal panel width: (ft.) 8 ft.
Color Family: Brown.
Color/Finish : Wood.
Contact Type Allowed: Above Ground.
Features: Paintable, Pressure Treated, Stainable.
Picket Top Style: Dog-eared.
Fence location: From the front corner of the house to the backside of the backyard
STAFF REPORT
CITY OF ANDERSON BOARD OF ARCHITECTURAL REVIEW
Application Number: BAR-26-58
Applicant: Loree Parkinson
Property Address: 908 W Whitner St (Westside Historic District)
Zoning of Property: LM, Low-Density Multi-Family
ANALYSIS
The applicant proposes to enclose the sleeping porch on the front right of the house. This proposal
was originally approved by the BAR in 2002 as part of renovations to the second story. The plan is
to replace the screen door with a solid door that opens onto the front porch and enclose the porch
to make a laundry room and master closet. The exterior cladding will match the current house.
When the element or alteration to be replaced is not original to the building, the basic principle to
consider is to not alter the perceived character of the building. When reviewing this application, the
Board should focus on the “Basic Principles of Historic Preservation” set forth in the Design
Guidelines, Historic Districts in Anderson, South Carolina that include:
• Respect the historic design character of the building.
• Protect and maintain significant features and stylistic elements.
• Preserve key, character-defining features of the property.
• Use building materials that appear similar to those used traditionally in Anderson.
The following sections of Chapter 4: Additions of the Design Guidelines apply to this request:
4.5 An addition should be compatible in scale with the primary structure.
• An addition should relate to the historic resources in mass, scale and form. It should be
designed to remain subordinate to the main structure.
4.6 An addition should be compatible in character with the primary structure.
The proposed restoration and renovations comply with the Design Guide. The proposed materials
are consistent with the existing materials. The proposed changes will not adversely affect the
perceived character of the building or neighborhood. Staff recommends approval.
STAFF REPORT
CITY OF ANDERSON BOARD OF ARCHITECTURAL REVIEW
Application Number: BAR-26-59
Applicant: Stephen Coughenour
Property Address: 407 Watson Ave. (North Anderson Historic District)
Zoning of Property: NR, Neighborhood Residential
ANALYSIS
The front center and front right chimneys are leaning and are at risk of collapse. The applicant
proposes to reduce the height of both to make them structurally sound.
When an element of a structure is altered, the basic principle to consider is to not alter the perceived
character of the building. When reviewing this application, the Board should focus on the “Basic
Principles of Historic Preservation” set forth in the Design Guidelines, Historic Districts in
Anderson, South Carolina that include:
• Respect the historic design character of the building.
• Protect and maintain significant features and stylistic elements.
• Preserve key, character-defining features of the property.
The following sections of Chapter 3: Rehabilitation of Historic Resources apply to this request:
Policy: Preserve historic architectural features and details.
Historic features, including original materials, architectural details and window and door openings
contribute to the character of a structure and are referred to as character-defining features. They
should be preserved when feasible.
3.1 Preserve and maintain significant stylistic and architectural features.
• Porches, turned columns, brackets, exposed rafter tails and jigsaw ornaments, if historic, are
examples of architectural features that should not be removed or altered.
• Do not remove or alter architectural details that are in good condition or that can be
repaired.
3.12 Preserve masonry features that define the overall historic character of the building.
• Examples are walls, porch piers and foundations.
RECOMMENDATION
Changing the height of the chimneys would alter the character of the building. The front center
chimney is a significant feature and stylistic element of the house architecture. As character defining
features the applicant has not made it clear how much the chimneys height would be reduced, or if
the chimney pots would be replaced. It does not appear this request is supported by the Design
Guidelines.
Source: City of Anderson website. First collected Nov 19, 2026.