Notice-of-Emergency-Code-Modification - LLR
Anderson County · Anderson County · Notices
Open the original document More from Anderson County
Text
Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.
NOTICE OF EMERGENCY
MODIFICATION TO 2021
SC BUILDING CODES
At their meeting on November 15, 2022, the S.C. Building Codes Council
approved an emergency modification request to delete the below exceptions
from the 2021 SC Plumbing Code and 2021 SC Building Code,
without substitution.
Approved Modifications:
• Exception 6 was deleted without substitution from Section 403.2 of
the 2021 IPC and from Section [P] 2902.2 of the 2021 IBC.
• Exception 2 was deleted without substitution from Section 403.1.1
of the 2021 IPC and from Section [P] 2902.1.1 of the 2021 IBC.
These modifications will take effect on January 1, 2023, and must be enforced by
all municipalities and counties in South Carolina.
1/5
South Carolina Department of Labor, Licensing and Regulation
South Carolina Building Codes Council
2021 Modification Index
Applicable Code:
Modification Index Number:
Code Section:
Modification:
Proponent:
Previous Code Cycles Previous Modification
Index Number Previous Code Section
IBC 2021-19
[P] 2902.1.1 Fixture Calculations
[P] 2902.1.1 Fixture calculations. To determine the occupant load of each sex, the total
occupant load shall be divided in half. To determine the required number of fixtures,
the fixture ratio or ratios for each fixture type shall be applied to the occupant load of each
sex in accordance with Table 2902.1. Fractional numbers resulting from applying the fixture
ratios of Table 2902.1 shall be rounded up to the next whole number. For calculations involving
multiple occupancies, such fractional numbers for each occupancy shall first be summed and then
rounded up to the next whole number.
Exceptions:
1. The total occupant load shall not be required to be divided in half where approved statistical
data indicates a distribution of the sexes of other than 50 percent of each sex.
2. Where multiple-user facilities are designed to serve all genders, the minimum fixture count
shall be calculated 100 percent, based on total occupant load. In such multiple-user user facilities,
each fixture type shall be in accordance with ICC A117.1 and each urinal that is provided shall
be located in a stall.
3. Distribution of the sexes is not required where single-user water closets and bathing room
fixtures are provided in accordance with Section 2902.1.2.
Emergency Modification approved by Council on 11-15-22
N/A
2021 International Building Code
2/5
South Carolina Department of Labor, Licensing and Regulation
South Carolina Building Codes Council
2021 Modification Index
Applicable Code:
Modification Index Number:
Code Section:
Modification:
Proponent:
Previous Code Cycles Previous Modification
Index Number Previous Code Section
IPC 2021-07
403.1.1 Fixture Calculations
403.1.1 Fixture calculations. To determine the occupant
load of each sex, the total occupant load shall be divided
in half. To determine the required number of fixtures, the
fixture ratio or ratios for each fixture type shall be applied
to the occupant load of each sex in accordance with Table
403.1. Fractional numbers resulting from applying the
fixture ratios of Table 403.1 shall be rounded up to the
next whole number. For calculations involving multiple
occupancies, such fractional numbers for each occupancy
shall first be summed and then rounded up to the next whole
number.
Exceptions:
1. The total occupant load shall not be required to be divided in half where approved statistical
data indicate a distribution of the sexes of other than 50 percent of each sex.
2. Where multiple-user facilities are designed to serve all genders, the minimum fixture count
shall be calculated 100 percent, based on total occupant load. In such multiple-user facilities,
each fixture type shall be in accordance with ICC A117.1 and each urinal that is provided
shall be located in a stall.
3. Distribution of the sexes is not required where single-user water closets and bathing room
fixtures are provided in accordance with Section 403.1.2.
Emergency Modification approved by Council on 11-15-22
N/A
2021 International Plumbing Code
3/5
South Carolina Department of Labor, Licensing and Regulation
South Carolina Building Codes Council
2021 Modification Index
Applicable Code:
Modification Index Number:
Code Section:
Modification:
Proponent:
Previous Code Cycles Previous Modification
Index Number Previous Code Section
IBC 2021-20
[P] 2902.2 Separate facilities
[P] 2902.2 Separate facilities. Where plumbing fixtures are
required, separate facilities shall be provided for each sex.
Exceptions:
1. Separate facilities shall not be required for dwelling
units and sleeping units.
2. Separate facilities shall not be required in structures
or tenant spaces with a total occupant load,
including both employees and customers, of 15 or fewer.
3. Separate facilities shall not be required in mercantile
occupancies in which the maximum occupant
load is 100 or fewer.
4. Separate facilities shall not be required in business
occupancies in which the maximum occupant
load is 25 or fewer.
5. Separate facilities shall not be required to be
designated by sex where single-user toilets rooms
are provided in accordance with Section 2902.1.2.
6. Separate facilities shall not be required where
rooms having both water closets and lavatory
fixtures are designed for use by both sexes and
privacy for water closets are installed in accordance
with Section 405.3.4 of the International
Plumbing Code. Urinals shall be located in an area
visually separated from the remainder of the facility
or each urinal that is provided shall be located in a stall.
Emergency Modification approved by Council on 11-15-22
N/A
2021 International Building Code
4/5
South Carolina Department of Labor, Licensing and Regulation
South Carolina Building Codes Council
2021 Modification Index
Applicable Code:
Modification Index Number:
Code Section:
Modification:
Proponent:
Previous Code Cycles Previous Modification
Index Number Previous Code Section
IPC 2021-08
403.2 Separate facilities
403.2 Separate facilities. Where plumbing fixtures are
required, separate facilities shall be provided for each sex.
Exceptions:
1. Separate facilities shall not be required for dwelling
units and sleeping units.
2. Separate facilities shall not be required in structures
or tenant spaces with a total occupant load,
including both employees and customers, of 15 or fewer.
3. Separate facilities shall not be required in mercantile
occupancies in which the maximum occupant
load is 100 or fewer.
4. Separate facilities shall not be required in business
occupancies in which the maximum occupant load
is 25 or fewer.
5. Separate facilities shall not be required to be
designated by sex where single-user toilet rooms
are provided in accordance with Section 403.1.2.
6. Separate facilities shall not be required where
rooms having both water closets and lavatory
fixtures are designed for use by both sexes and
privacy for water closets is provided in accordance
with Section 405.3.4. Urinals shall be located in an
area visually separated from the remainder of the
facility or each urinal that is provided shall be
located in a stall.
Emergency Modification approved by Council on 11-15-22
N/A
2021 International Plumbing Code
5/5
Source: Anderson County website. First collected Nov 20, 2026.