Board of Architectural Review Meeting — Agenda Packet
Town of Blythewood · Richland County · Board of Architectural Review · meeting of Nov 16, 2026 · Agenda packets
Open the original document More from Town of Blythewood
Text
Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.
Page 1 of 2
Blythewood Board of Architectural Review Meeting
Doko Manor
100 Alvina Hagood Circle
Blythewood, SC 29016
Monday, November 16, 2026
5:30 PM
Agenda
I. Call to Order
A. Roll Call
B. Notification and Posting of the Agenda
C. Pledge of Allegiance
D. Approval of Minutes
a June 17, 2026 BAR Minutes
II. Action Item
A. 113 Main Street Certificate of Appropriateness Application
B. Board of Architectural Review and Certificate of Appropriateness Ordinance Revision
III. Open Citizen Comments
This portion of the meeting is designated for Public Comments as provided for by
municipal ordinance. Public Comments can be on any subject related to Town business.
Each speaker will have up to three (3) minutes to address the Board of Architectural
Review. All comments will be entered into the official record, and no action will be taken
during the hearing itself.
IV. Adjournment
Page 1 of 64
Page 2 of 2
Accessibility Notice
In accordance with the Americans with Disabilities Act (ADA), individuals who need an
accommodation or auxiliary aid to participate in this meeting should contact Sharon Durst at
(803) 754-0501 or dursts@townofblythewoodsc.gov.
Please provide notice as far in advance of the meeting as possible so reasonable
accommodations can be arranged.
Page 2 of 64
TOWN OF BL YTHEWOOD | PLANNING & ZONING
171 Langford Road | P .O. Box 1004 | Blythewood, SC 29016 | www.townoϐblythewoodsc.gov
(803) 754-0501 | polend@townoϐblythewoodsc.gov
Staff Report
113 Main Street Certiϐicate of Appropriateness Application
DATES: November 16, 2026
TO: Blythewood Board of Architectural Review
FROM: Douglas Polen, Town Manager
SUBJECT: Certiϐicate of Appropriateness, 113 Main Street, Advance
Auto Parts
ACTION
REQUESTED:
Review application for approval, approval with conditions,
or denial
PURPOSE
The applicant, Zach Grogan, on behalf of Advance Auto Parts, has submitted an
application for a Certiϐicate of Appropriateness (COA) for the construction of a new
retail building at 113 Main Street, near the intersection of Main Street and
Blythewood Road.
The proposed development consists of a one-story, approximately 6,889-square-
foot commercial building measuring approximately 83 feet by 83 feet. The project
includes associated parking, landscaping, pedestrian access, and related site
improvements.
The original application, dated July 31, 2026, included architectural elevations
depicting a combination of stucco and natural stone exterior materials. Revised
elevations, dated October 20, 2026, propose two shades of gray thin-brick veneer,
black storefront framing and metal canopies, and a horizontal yellow accent stripe
consistent with Advance Auto Parts' corporate branding.
The property is located along Main Street and is subject to review under the Town's
applicable architectural design standards.
Page 3 of 64
ANALYSIS
The proposed development is subject to the architectural requirements of the Town
of Blythewood Zoning Ordinance, including §155.502, General Architectural Design
Standards, and applicable provisions of §155.182 governing development within the
Town Center District, subject to confirmation of the property's zoning designation.
Building Design and Architectural Compatibility
The ordinance establishes standards intended to promote architectural
compatibility with surrounding development, including provisions addressing
building orientation, façade articulation, exterior materials, rooflines, and
architectural character.
The proposed building features a central storefront entrance, black metal canopies,
projecting façade elements, and variations in parapet height. These features provide
some architectural articulation and visual interest.
However, the design also incorporates substantial areas of uninterrupted masonry,
with storefront glazing concentrated primarily around the central entrance. The
overall building design is relatively simple and reflects a contemporary corporate
retail format.
The existing ordinance addresses compatibility with surrounding buildings and
encourages architectural treatments that contribute to the character of the area. The
surrounding Main Street development generally incorporates more traditional
architectural elements, including natural brick, lighter exterior finishes, and varied
façade treatments.
The Board should consider whether the proposed building adequately satisfies the
applicable architectural compatibility and façade design requirements, particularly
with respect to the extent of storefront glazing, architectural detailing, and
treatment of large wall surfaces.
Exterior Building Materials
The revised architectural elevations identify two primary exterior materials: Glen-
Gery Stone Grey Klaycoat thin brick and Glen-Gery Titanium Metalix thin brick, both
with charcoal-colored grout.
Section 155.182(B)(5) identifies acceptable primary exterior building materials for
commercial structures within the Town Center District, including full brick and
certain precast concrete panels incorporating thin brick.
Page 4 of 64
The submitted elevations identify the proposed products but do not provide
sufficient information regarding the exterior wall assembly or installation method
to establish compliance with the applicable material requirements.
Additional manufacturer specifications or construction details may be necessary to
confirm that the proposed thin-brick system satisfies the ordinance.
Exterior Colors and Accent Treatments
The proposed building incorporates two shades of gray masonry, black storefront
framing and canopies, and a horizontal yellow accent stripe.
Section 155.502 establishes standards for exterior colors and their compatibility
with surrounding development. The ordinance discourages incompatible color
treatments, limits the use of bold primary colors on building façades except as
accents, and prohibits certain bright or attention-grabbing colors.
The proposed gray masonry differs from the natural brick and lighter exterior
finishes commonly found on nearby Main Street buildings. However, the ordinance
does not expressly require that new construction replicate the colors or materials of
adjacent structures.
The yellow stripe is proposed as an architectural accent rather than a primary
exterior finish. Additional information regarding the specific color and extent of the
treatment may assist the Board in determining compliance with the applicable color
standards.
Building Orientation and Storefront Design
The architectural elevations depict a central glazed storefront and entrance canopy,
with more limited fenestration along the remaining exterior walls.
The ordinance includes requirements addressing commercial storefront design,
building orientation, and the relationship between buildings and public streets.
The Board should evaluate whether the proposed entrance location, storefront
configuration, and pedestrian connections satisfy the applicable requirements,
particularly given the property's location along Main Street.
Roofline and Mechanical Equipment
The building incorporates a flat roof concealed by parapet walls of varying heights.
The elevations also identify rooftop HVAC equipment.
Page 5 of 64
The existing ordinance permits flat-roof commercial buildings subject to applicable
architectural treatment and screening requirements.
Additional information may be necessary to determine whether the proposed
parapets adequately screen rooftop mechanical equipment from public view.
Landscaping and Site Improvements
The submitted site and landscaping plans depict 28 parking spaces, street trees,
interior parking lot landscaping, foundation plantings, and perimeter landscape
buffers.
The plans also identify proposed connections to adjoining properties and associated
circulation improvements.
Compliance with applicable landscaping, buffering, parking, and site development
requirements will require verification during the development review process.
The architectural elevations indicate that the proposed dumpster enclosure will
match the building's exterior finish. Additional enclosure details may be necessary
to confirm compliance with applicable screening requirements.
RECOMMENDATION
To be determined following receipt of the Town Architect's review and any additional
information provided by the applicant.
Page 6 of 64
TOWN OF BLYTHEWOOD
171 Langford Road
Blythewood, SC 29016
Office: 803-754-0501 E-mail:
yarboroughs@townofblythewoodsc.gov
www.townofblythewoodsc.gov
Town of Blythewood Board of Architectural Review
Submittal Requirements and Checklist
An application properly filed with Zoning by 4:00 PM on the published application deadline (please refer to official BAR Calendar) will be
reviewed by the Board of Architectural Review at a public hearing to be held on the third Monday of the following month at 5:30 PM
at Doko Manor, 100 Alvina Hagood Circle, Blythewood, SC 29016.
*APPLICANT TO INCLUDE THIS SHEET WITH APPLICATION SUBMITTAL*
Applicable sections of the Zoning Ordinance reviewed and listed correctly on application (i.e. 155.428)
All sections of application completed (please ensure all fields completed and responses are legible. Attach separate sheet if
necessary)
Signed and witnessed Letter of Agency submitted (If applicant not property owner)
Applicant signature on last page of document
Conceptual Site Plan and/or Landscaping Plan (digital and hardcopy) provided to illustrate site layout, parking, landscaping, etc.
Samples of exterior materials, textures, and colors
Photographs of all sides of the existing structure if applicable and photographs of the adjoini ng properties
Application fee remitted at time of submittal (Please ensure project value notated on application. Checks to be made payable to
Town of Blythewood)
*Staff to review and sign-off on checklist at time of submittal
Date and time submitted:
Staff initials:
INCOMPLETE APPLICATIONS WILL NOT BE ACCEPTED
Applications are accepted:
Monday - Friday from 8:00 AM to 4:00 PM
SO THAT WE CAN BETTER SERVE ALL APPLICANTS: ON THE LAST DAY OF THE APPLICATION PERIOD, APPLICANTS MUST HAVE ALL
DOCUMENTS AND PAYMENT TO ZONING STAFF BY 4:00 PM TO ENSURE PROCESSING AND SCHEDULING FOR THE
CORRESPONDING PUBLIC HEARING DATE.
Page 7 of 64
Page 8 of 64
Applicable sections of the Zoning Ordinance – Supplemental Information
155.500 – Overall site design, objective.
building oriented to parking areas and shared internal driveways
Parking located to the side and rear of the structure, and not between the front of
the structure and the street
ingress and egress preliminarily reviewed by SCDOT and consistent with traffic
impact analysis
155.502 – Building orientation and forms.
(B)(1)(a) Two 2-foot off-sets provided on each building face
(B)(1)(c) 4’8” parapet height variation provided on each building face
(B)(3)(b) Appropriate parapet design provided on each building face
(C)(2) Black metal cantilevered awnings, complimentary to the storefront window
and door system proposed. Coordinated with the overall visual design of the
building
(E)(2)(a): proposed materials: Stucco hard coat (P) and natural Stone (P).
(E)(2)(b): (P) signifies a primary material used to construction70% or moreof a
visible façade. (A) signifies an accent material used to construct30% or lessof a
visible façade. Any material designated as (P) may also be used as an accent
material.
Page 9 of 64
PALMETTOPEDIATRICPALMETTOPEDIATRIC
PROPOSED RI/RO DRIVEWAY
EXISTING FULLACCESS DRIVEWAY
7
4
9
Hwy 21 (Main Street)RETAIL83'X83'28 PARKINGSPACES POND
8
LOT 11.45 ACRES
LOT 21.55 ACRESLOT 32.56 ACRES
TRANSITION YARD TYPE B(MIN WIDTH 10')
INTERIOR PLANTINGTYPE C
INTERIOR PLANTINGTYPE C
STREET PROTECTIVEYARD TYPE E
FOUNDATION PLANTINGINSTALL PLANT MATERIALACCORDINGLY
TRANSITION YARD TYPE B(MIN WIDTH 10')TRANSITION YARD TYPE B(MIN WIDTH 10')
TRANSITION YARD TYPE B(MIN WIDTH 10')
TRANSITION YARD TYPE B(MIN WIDTH 10')
LOT 2 AND LOT 3 PARKING TOTIE IN TOGETHER AT LOT LINEIN THE FUTURE
FUTURECONNECTIONTO LOT 1 FUTURECONNECTIONTO LOT 1
LANDSCAPING NOTES1.ALL TREES, SHRUBS, AND PLANTS SHALL CONFORM TO ACCEPTED STANDARDSESTABLISHED BY THE AMERICAN ASSOCIATION OF NURSERYMEN.2.ALL PLANTING BEDS SHALL RECEIVE 4" OF DOUBLE-GROUND HARDWOOD BARKMULCH. ALL AREAS OTHER THAN PLANT BEDS SHALL BE SODDED OR SEEDED ASSPECIFIED.3.ALL TREES IN LAWN AREAS SHALL RECEIVE 8' DIAMETER MULCH RING, 4" DEPTH.4.ALL ROOT BALLS REMOVED FROM CONTAINERS SHALL BE SCARIFIED PRIOR TOPLANTING AND BACKFILLING. ALL PLANTS SHALL BE SOAKED WITH WATERIMMEDIATELY AFTER PLANTING. AN 4' DIAMETER MULCH RING (MIN. 4" DEPTH)SHALL BE INSTALLED AROUND ALL TREES.5.LOCATIONS OF UTILITIES SHOWN ARE BASED ON EVIDENCE OBSERVED AT THETIME OF SURVEY. OTHER UTILITIES MAY EXIST THAT ARE NOT SHOWN. IT SHALLBE THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE EXISTENCE ANDACTUAL LOCATION OF ALL EXISTING UTILITY LINES, AND TO PROTECT THESE LINESDURING CONSTRUCTION.6.CONTRACTOR SHALL MAINTAIN AND GUARANTEE ALL PLANTINGS FOR ONE YEARAFTER INSTALLATION AND SHALL REPLACE PLANTINGS AS NECESSARY.7.TREES AND SHRUBS TO BE TRANSPLANTED SHALL BE TRANSPLANTED AS SOON ASPOSSIBLE AFTER CONSTRUCTION BEGINS. CONTRACTOR SHALL BE RESPONSIBLEFOR REMOVAL, STORAGE, WATERING, PLANTING, AND MAINTENANCE OFEXISTING TREES AND SHRUBS TO BE TRANSPLANTED.
SHEET
© COPYRIGHT 2026 BY BLUE RIDGEENGINEERING PLLC, SC LICENSE #C-02437, ALL RIGHTS RESERVED. THIS PLAN MAY NOT BE RE-USED, SOLD, LOANED OR GIVEN TO OTHERS. REPRODUCTION OR PHOTOCOPYINGOF THIS PLAN WITHOUT THE WRITTENCONSENT OF BLUE RIDGE ENGINEERING PLLC IS PROHIBITED.Prepared for: PROJECT #24016DRAWN BY:MDSORIGINAL ISSUE DATE:07/28/2026Proposed Commercial DevelopmentBlythewood Rd (S-59) at Main Street (Hwy 21)Blythewood, SC31 Wade Hampton BlvdGreenville, SC 29609PRELIMINARY - NOT FOR CONSTRUCTION
PRELIMINARYNOT FOR CONSTRUCTIONBlue Ridge Engineering PLLC924 Main Street - Suite 200North Wilkesboro, NC 28659336.838.2500www.ridge.blueSC Firm #C-02437
LANDSCAPING REQUIREMENTSINTERIOR PLANTINGREQUIREDSPACES MAY BE NO MORE THAN 50'FROM TRUNK OF LARGE CANOPYTREE 155.384(C)(2)(b)PROVIDED6 PARKING LOT SHRUBSREQUIRED 30 (5 PER TREE)PROVIDED 30 STREET YARD TREESREQUIRED3 (40' ON AVERAGE PER 40 LINEARFEET OF FRONTAGE EXCLUDINGACCESS) (155.384.(E))PROVIDED3 TRANSITION YARD SHRUBSREQUIRED SHRUBS (AT LEAST 4' AT MATURITY)MUST HAVE NO UNOBSTRUCTEDOPENINGS WIDER THAN 4' (155.384.(B))PROVIDED68 SHRUBSFOUNDATION PLANTINGREQUIRED CONTINUOUS PLANT BED WITHAVERAGE WIDTH 4' AND MINIMUMWIDTH OF 2' ALONG THE PERIMETER. (EXCEPTIONS FORBUILDING SERVICE REQUIREMENTSAND FRONT FACADES) (155.383 (E))PROVIDED 42 SHRUBS
SYM.QTY
NAMEPLANTING LIST3
SIZE AT PLANTING
13NELLIE STEVENS HOLLYIlex 'Nellie R. Stevens'
8' MIN. HEIGHT2" MIN. CALIPER AT6" ABOVE GROUND
30
3 GALLON
DYSTYLIUM VINTAGE JADE'vintage jade' dystiliumRED MAPLE 'OCTOBER GLORY'Acer Rubrum 'october glory'CHINESE PISTACHEPistacia chinensis6
8' MIN. HEIGHT2" MIN. CALIPER AT6" ABOVE GROUND
55WAXLEAF LIGUSTRUMLigustrum japonicum
Preliminary Landscape Planting PlanC-990603001" = 30'SCALE:
42CRIMSON FIRE LOROPETALUM'crimson fire' loropetalum
3 GALLON
3 GALLON3 GALLON
Page 10 of 64
BLACK HOUSING (LIGHTS)
22'-0" T.O.M.17'-6 1/4"+/- ROOF LINE @ FRONTY1 ACCENT STRIPE STUCCOB1 STUCCOA1 STUCCO
BLACK STOREFRONT SYSTEM29'-4" PROTRUDING 24"
PAINTPAINTPAINT
26'-8" T.O.M.13'-4"BOTTOM OF ACCENT10'-6"
12'-0"
C AB BLACK CANOPY ANDTURNBUCKLES
ST1 STONY POINT CHISEL CUTLEDGE NATURAL STONEST1 STONE WATER TABLE2'-8"
35'-4" 18'-4"
THIS WILL AFFECT THEFOOTPRINT.
1
2
3
ABC 28'-0"8"18'-4"8"35'-4"
27'-0"8"28'-0"8"26'-8"
83'-0"
BLACK LETTERSET
2'-0"
HVAC UNITHVAC UNIT
BLACK HOUSING (LIGHTS)
22'-0" T.O.M.
17'-6 1/4"+/- ROOF LINE @ FRONTY1 ACCENT STRIPE STUCCOB1 STUCCOA1 STUCCO
BLACK STOREFRONT SYSTEM29'-4" PROTRUDING 24"
PAINTPAINTPAINT
26'-8" T.O.M.13'-4"BOTTOM OF ACCENT10'-6"
12'-0"
3 12BLACK CANOPY ANDTURNBUCKLES
ST1 STONY POINT CHISEL CUTLEDGE NATURAL STONEST1 STONE WATER TABLE2'-8"
26'-8" 27'-0"
BLACK LETTERSETHVAC UNITHVAC UNIT
83'-0"
BLACK HOUSING (LIGHTS)
22'-0" T.O.M.17'-6 1/4"+/- ROOF LINE @ FRONTY1 ACCENT STRIPE STUCCOB1 STUCCOA1 STUCCO
BLACK STOREFRONT SYSTEM29'-4" PROTRUDING 24"
PAINTPAINTPAINT
26'-8" T.O.M.13'-4"BOTTOM OF ACCENT10'-6"
12'-0"
1 32BLACK CANOPY ANDTURNBUCKLES
ST1 STONY POINT CHISEL CUTLEDGE NATURAL STONEST1 STONE WATER TABLE2'-8"
27'-0" 26'-8"
BLACK LETTERSETHVAC UNITHVAC UNIT
83'-0"
83'-0"
BLACK HOUSING (LIGHTS)
22'-0" T.O.M.
16'-0"+/- ROOF LINE @ REARY1 ACCENT STRIPE STUCCOB1 STUCCOA1 STUCCO
BLACK STOREFRONT SYSTEM29'-4" PROTRUDING 24"
PAINTPAINTPAINT
26'-8" T.O.M.13'-4"BOTTOM OF ACCENT10'-6"
12'-0"
A CB
ST1 STONY POINT CHISEL CUTLEDGE NATURAL STONEST1 STONE WATER TABLE2'-8"
27'-0" 26'-8"
BLACK LETTERSETHVAC UNITHVAC UNIT
83'-0"
NOTETHERE WILL BE NO CANOPY AT THE REARDELIVERY ELEVATION . IT WOULD CAUSE AHAZARD FOR DELIVERY TRUCKS THAT BACK INPARALLEL TO THE BUILDING.
A1 SCUPPERS AND DOWNSPOUTS
3DD3
1DD3
2DD3
4DD3
STORE #TBDADDRESS TBD
6,889 S.F.CHECK BY:ALL REPORTS, PLANS, SPECIFICATIONS,FIELD DATA, NOTES AND OTHERDOCUMENTS, INCLUDING ALLDOCUMENTS ON ELECTRONIC MEDIA,PREPARED BY THE DESIGNPROFESSIONAL AS INSTRUMENTS OFSERVICE SHALL REMAIN THE PROPERTYOF THE DESIGN PROFESSIONAL.DISSEMINATION MAY NOT BE MADEWITHOUT PRIOR CONSENT OF THEDESIGN PROFESSIONAL. ALL COMMONLAW RIGHTS OF COPYRIGHT ANDOTHERWISE, ARE HEREBY SPECIFICALLYRESERVED.
VERSION Q1-26 83x83REVISIONSREVDATEDESCRIPTION
DATEGROSS SQ. FT.PROJECT #DRAWN BY:
BLYTHEWOOD, SC 29016
PRELIMINARY DRAWINGS -NOT FOR CONSTRUCTIONPRELIMINARY DRAWINGS -NOT FOR CONSTRUCTION
PRELIMINARY DRAWINGS -NOT FOR CONSTRUCTIONPRELIMINARY DRAWINGS -NOT FOR CONSTRUCTION
7-21-26
THESE DOCUMENTS ARE PROVIDED AS ACONSTRUCTION DOCUMENT TEMPLATEFOR THIS BUILDING TYPE. THESEDRAWINGS MUST BE REVIEWED ANDADAPTED BY A LICENSED ARCHITECTAND/OR ENGINEER TO MEET ALL STATEAND LOCAL JURISDICTIONALREQUIREMENTS FOR SITE-SPECIFICPROJECTS. MODIFICATIONS THATCHANGE THE IMAGE ELEMENTS MUST BEAPPROVED BY AN AAP REPRESENTATIVEPRIOR TO CONSTRUCTION. THE ISSUEROF THESE DOCUMENTS ASSUMES NORESPONSIBILITY OR LIABILITY FOR THEUSE OF THESE PLANS FOR ANY PROJECT.
Q1-26
STAFF334STAFF
DD3EXTERIORELEVATIONS
Page 11 of 64
PHOTO OF SUBJECT PROPERTY
Page 12 of 64
PHOTO OF SUBJECT PROPERTY
Page 13 of 64
PHOTO OF 109 MAIN ST
Page 14 of 64
PHOTO OF 121 BLYTHEWOOD RD
Page 15 of 64
PHOTO OF 109 BLYTHEWOOD RD
Page 16 of 64
PHOTO OF 121 BLYTHEWOOD RD
Page 17 of 64
BLACK HOUSING (LIGHTS)
22'-0" T.O.M.17'-6 1/4"+/- ROOF LINE @ FRONTBLACK STOREFRONT SYSTEM29'-4" PROTRUDING 24"
26'-8" T.O.M.13'-4"BOTTOM OF ACCENT10'-6"
12'-0"
C ABBLACK CANOPY ANDTURNBUCKLES
35'-4"18'-4"
1
2
3
ABC 28'-0"8"18'-4"8" 35'-4"
27'-0"8"28'-0"8"26'-8"
83'-0"
BLACK LETTERSET
2'-0"
HVAC UNIT
BLACK HOUSING (LIGHTS)
22'-0" T.O.M.
17'-6 1/4"+/- ROOF LINE @ FRONTBLACK STOREFRONT SYSTEM29'-4" PROTRUDING 24"
26'-8" T.O.M.13'-4"BOTTOM OF ACCENT10'-6"
12'-0"
3 12BLACK CANOPY ANDTURNBUCKLES
26'-8" 27'-0"
BLACK LETTERSETHVAC UNITHVAC UNIT
83'-0"
BLACK HOUSING (LIGHTS)
22'-0" T.O.M.17'-6 1/4"+/- ROOF LINE @ FRONTBLACK STOREFRONT SYSTEM29'-4" PROTRUDING 24"
26'-8" T.O.M.13'-4"BOTTOM OF ACCENT10'-6"
12'-0"
1 32BLACK CANOPY ANDTURNBUCKLES
27'-0" 26'-8"
BLACK LETTERSETHVAC UNITHVAC UNIT
83'-0"
83'-0"
BLACK HOUSING (LIGHTS)
22'-0" T.O.M.
16'-0"+/- ROOF LINE @ REARBLACK STOREFRONT SYSTEM29'-4" PROTRUDING 24"
26'-8" T.O.M.13'-4"BOTTOM OF ACCENT10'-6"
12'-0"
A CB
27'-0" 26'-8"
BLACK LETTERSETHVAC UNITHVAC UNIT
83'-0"NOTETHERE WILL BE NO CANOPY AT THE REARDELIVERY ELEVATION . IT WOULD CAUSE AHAZARD FOR DELIVERY TRUCKS THAT BACK INPARALLEL TO THE BUILDING.
3DD6
1DD6
2DD6
4DD6
EXTERIOR:MATERIAL:LOCATION:MATERIAL SCHEDULE
SAFETYSAFETY YELLOWBOLLARDS, MANDATED SAFETY AREASDOWNSPOUTS AND SCUPPERSBKADVANCE AUTO PARTS BLACK
EXTERIOR FACADEBR-1GLEN-GERYSTONE GREY KLAYCOAT THIN BRICKEXTERIOR FACADEBR-2GLEN-GERYTITANIUM METALIX THIN BRICKGROUTGROUTMAPEI 5047 CHARCOAL
BR-2BR1PAINTED Y1BR1
YELLOW STRIPE PAINTED BRICKY1ADVANCE AUTO PARTS YELLOW
3DD6
1DD6
2DD6
4DD6
BR-2BR1PAINTED Y1BR1BR-2BR1PAINTED Y1BR1BR-2BR1PAINTED Y1BR1
SCUPPERS AND DOWNSPOUTSFINISH BK
NOTE: DUMPSTER ENCLOSURE TOMATCH BUILDING FINISH
STORE #TBDADDRESS TBD
6,889 S.F.CHECK BY:ALL REPORTS, PLANS, SPECIFICATIONS,FIELD DATA, NOTES AND OTHERDOCUMENTS, INCLUDING ALLDOCUMENTS ON ELECTRONIC MEDIA,PREPARED BY THE DESIGNPROFESSIONAL AS INSTRUMENTS OFSERVICE SHALL REMAIN THE PROPERTYOF THE DESIGN PROFESSIONAL.DISSEMINATION MAY NOT BE MADEWITHOUT PRIOR CONSENT OF THEDESIGN PROFESSIONAL. ALL COMMONLAW RIGHTS OF COPYRIGHT ANDOTHERWISE, ARE HEREBY SPECIFICALLYRESERVED.
VERSION Q1-26 83x83REVISIONSREVDATEDESCRIPTION
DATEGROSS SQ. FT.PROJECT #DRAWN BY:
BLYTHEWOOD, SC 29016
PRELIMINARY DRAWINGS -NOT FOR CONSTRUCTIONPRELIMINARY DRAWINGS -NOT FOR CONSTRUCTION
PRELIMINARY DRAWINGS -NOT FOR CONSTRUCTIONPRELIMINARY DRAWINGS -NOT FOR CONSTRUCTION
10-20-26
THESE DOCUMENTS ARE PROVIDED AS ACONSTRUCTION DOCUMENT TEMPLATEFOR THIS BUILDING TYPE. THESEDRAWINGS MUST BE REVIEWED ANDADAPTED BY A LICENSED ARCHITECTAND/OR ENGINEER TO MEET ALL STATEAND LOCAL JURISDICTIONALREQUIREMENTS FOR SITE-SPECIFICPROJECTS. MODIFICATIONS THATCHANGE THE IMAGE ELEMENTS MUST BEAPPROVED BY AN AAP REPRESENTATIVEPRIOR TO CONSTRUCTION. THE ISSUEROF THESE DOCUMENTS ASSUMES NORESPONSIBILITY OR LIABILITY FOR THEUSE OF THESE PLANS FOR ANY PROJECT.
Q1-26
STAFF334STAFF
DD6EXTERIORELEVATIONS
SCALE:1DD61/8" = 1'-0"NORTH FACING ELEVATION
SCALE:2DD61/8" = 1'-0"WEST FACING ELEVATION
SCALE:3DD61/8" = 1'-0"HWY 21 EAST FACING ELEVATION
SCALE:4DD61/8" = 1'-0"SOUTH FACING ELEVATION
SCALE:5DD61/8" = 1'-0"NORTH FACING ELEVATION
SCALE:6DD61/8" = 1'-0"PLAN
SCALE:7DD61/8" = 1'-0"SITE PLANN
N
Page 18 of 64
TOWN OF BLYTHEWOOD | BAR STANDARDS & PROCEDURES | WORKING DRAFT 04
Architectural and BAR procedure draft only | Not for adoption | November 11, 2026 | Page 1
TOWN OF BLYTHEWOOD
Board of Architectural Review
Architectural Standards & Procedures
WORKING DRAFT NO. 4 | NOVEMBER 11, 2026
KK-to-draft reconciliation and confirmed Town Manager decisions | For Town Attorney and staff review; not for
introduction or adoption
Purpose
This fourth checkpoint incorporates the Town Manager’s final November 11 procedural decisions and
reconciles the draft against Kendig Keast’s May 2025 proposed architectural overlay, BAR organization, and
general development-review procedures. Settled policy choices remain unchanged. The comparison
identifies provisions retained, intentionally revised, governed elsewhere, or reserved for Town Attorney
review.
How to use this document
PART I Consolidated proposed architectural standards, including materials, building types, alterations,
colors, murals, lighting, and accessory buildings. Section numbers remain provisional.
PART II Historic-property architectural, demolition, and relocation policy for integration with the existing
historic-preservation ordinance after legal review.
PART III BAR administration, application review, hearings, Certificates of Appropriateness, modifications,
enforcement, and occupancy coordination. PART IV records policy decisions; PART V lists legal and
codification checks; PART VI compares this draft to Kendig Keast. Only Parts I–III are proposed operative
text.
APPENDIX Original Kendig Keast figures retained solely as source illustrations; superseded figures do not
state the proposed rules.
Important boundaries
This is a working architectural and BAR-procedure rewrite drawing from Kendig Keast §§2.03.01, 6.02.04 and
relevant portions of Chapter 7, not an adoption of Kendig Keast’s proposed zoning districts or complete land
development ordinance. Existing Town zoning districts and adopted historic, sign, zoning, and building
regulations remain controlling except where lawfully amended. The uploaded March 2026 Code text still
describes a seven-member BAR; the Town Manager reports a subsequent change to five members. The Town
Attorney must verify and incorporate the actual adopted amendment before codification.
Source basis: Kendig Keast, Blythewood Land Development Ordinance Update, Public Hearing Draft for Council, May 22,
2025, §2.03.01; current Blythewood Chapter 155, including §§155.315–155.316 and historic-preservation provisions; Town
Manager working decisions through November 11, 2026. All citations to proposed sections are provisional.
Page 19 of 64
TOWN OF BLYTHEWOOD | BAR STANDARDS & PROCEDURES | WORKING DRAFT 04
Architectural and BAR procedure draft only | Not for adoption | November 11, 2026 | Page 2
PART I | PROPOSED ARCHITECTURAL STANDARDS
DRAFTING NOTE | PROVISIONAL SECTION NUMBERS. This is a consolidated working text, not a codification.
Final ordinance numbering, geographic boundaries, review procedures, and conflicts with existing §§155.315–
155.316, 155.495–155.505, 155.535–155.544, and other adopted provisions require Town Attorney review.
Sec. 155.499. Purpose, applicability, and review principles.
(A) Purpose. These standards seek durable, attractive, coherent development that contributes to
Blythewood’s character while allowing traditional and contemporary architectural approaches. No single
architectural style or mandatory historical imitation is required.
(B) Applicability. Subject to final ordinance mapping and Certificate of Appropriateness provisions,
architectural review applies to (1) covered development in the Town Center (TC) district; (2) commercial,
mixed-use, multifamily, single-family attached, and civic development fronting Main Street/Wilson
Boulevard, Blythewood Road, McNulty Road/Extension, and Langford Road within Town limits; and (3)
other commercially zoned or commercially used property in the Town, including covered commercial
uses in planned developments. The Town’s currently adopted zoning districts, not Kendig Keast’s
proposed district names, govern applicability. An existing single-family detached dwelling used as a
residence is exempt from ordinary architectural review, including when located on one of the four
corridors or in TC; designated historic-property requirements, if applicable, remain separate. A change to
commercial use does not itself require architectural reconstruction, but qualifying exterior work
associated with the use is subject to review.
(C) Consistent material rule. The same 70-percent primary-material / 30-percent accent-material
framework applies to prominent exterior elevations of covered commercial, mixed-use, civic,
multifamily, and townhome buildings. Enhanced-corridor status increases the importance of
architectural composition and streetscape treatment, not the percentage of required masonry or primary
materials. Fully concealed service elevations are addressed separately.
(D) Enhanced corridors. Main Street/Wilson Boulevard, Blythewood Road, McNulty Road and McNulty
Road Extension, and Langford Road are the four enhanced architectural corridors, within Town limits.
Main Street/Wilson Boulevard emphasizes pedestrian-oriented frontages; the other three allow context-
appropriate auto-oriented development. No additional streets or new zoning districts are created by this
draft.
(E) Review principles. Staff, the Town-retained architect, and the BAR shall evaluate architectural design as
a whole under the written standards, rather than personal preference for a style, color, or architectural
fashion. Significant BAR decisions shall be supported by specific findings tied to the applicable standards.
Major applications remain subject to citizen BAR approval under procedures to be drafted separately.
(F) Limits of authority. BAR architectural approval does not grant relief from zoning, permitted uses, lot
dimensions, setbacks, building height, parking, drainage, fire and building codes, access, SCDOT
encroachments, or adopted landscaping standards. Architectural alternatives may be approved only
where this article expressly permits them. Sign content and sign permits are governed by the sign
ordinance, not by BAR architectural review.
Page 20 of 64
TOWN OF BLYTHEWOOD | BAR STANDARDS & PROCEDURES | WORKING DRAFT 04
Architectural and BAR procedure draft only | Not for adoption | November 11, 2026 | Page 3
Sec. 155.500. Building orientation, site relationship, and vehicle
facilities.
(A) General orientation. Principal building entrances and prominent elevations shall address the street or
relevant internal pedestrian environment through appropriate entrances, pedestrian connections, and
architectural treatment. Buildings in multibuilding developments may orient to internal streets,
courtyards, or shared open spaces.
(B) Main Street/Wilson Boulevard. Pedestrian-oriented building frontage and side or rear parking are
strongly preferred. The BAR may approve a comparably attractive alternative where site conditions
warrant, subject to zoning, site-plan, and transportation requirements.
(C) Blythewood Road, McNulty Road/Extension, and Langford Road. Auto-oriented site arrangements,
including lawful front parking, are permitted. The design shall provide coherent street-facing
architecture, safe pedestrian connections, and landscaping required under applicable site standards; a
traditional downtown storefront arrangement is not mandatory.
(D) Corner sites. Both street-facing elevations shall receive appropriate architectural treatment. On
prominent enhanced-corridor intersections, the principal building is encouraged to anchor the corner,
particularly for fuel-sales developments, but no automatic double-storefront mandate is imposed.
(E) Vehicle access and circulation. Driveways, internal circulation, parking dimensions, traffic safety, and
stacking capacity shall comply with applicable site-development and transportation requirements.
Architectural approval does not replace those approvals.
(F) Conventional drive-throughs. For restaurants, banks, pharmacies, and similar uses, drive-through
service windows, lanes, and associated vehicle queues shall be located at the side or rear of the principal
building. No drive-through lane or queue may occupy the area between the principal building and an
adjoining public street. The BAR may not waive this restriction. Ordinary access driveways and lawful
parking are not prohibited.
(G) Car wash exception. A car wash may orient its entrance and exit toward the street and may place
queuing between the principal building and a public street where otherwise lawful. Queues shall remain
on-site; screening and landscaping shall be governed by applicable site-development standards. This
exception does not extend to conventional drive-through uses.
Sec. 155.501. Landscaping, screening, fencing, and service equipment.
(A) Landscape coordination. Required landscape buffers, planting quantities, screening dimensions,
stormwater planting, and parking-area landscaping are governed by the Town’s applicable landscaping
and site-development ordinances, not by new numerical requirements in this architectural article.
Architectural compatibility requirements supplement those rules.
(B) Vehicle-oriented uses. Car wash queues, vacuum stations, and exposed service equipment should be
visually softened or screened where prominent from public streets or neighboring property. Specific
plantings, buffer depths, and sight-distance requirements shall be established in the landscaping
ordinance rather than invented by the BAR.
(C) Optional decorative fencing. Decorative fences are not required solely by this article. When provided
on covered commercial, mixed-use, or civic frontages, fences shall be attractive, durable, and compatible
with the principal building. Ornamental metal, appropriate picket fencing, and comparable decorative
Page 21 of 64
TOWN OF BLYTHEWOOD | BAR STANDARDS & PROCEDURES | WORKING DRAFT 04
Architectural and BAR procedure draft only | Not for adoption | November 11, 2026 | Page 4
treatments are permitted. Exposed chain-link and ordinary solid wood privacy fencing shall not be used
as decorative commercial frontage fencing; utilitarian screening is governed separately.
(D) Columns and gates. Brick or stone columns, including regularly spaced decorative columns, are
encouraged where appropriate but are not mandatory or subject to fixed spacing. Gates shall be durable,
functional, and visually coordinated with adjacent fences or buildings.
(E) Ground-level service and mechanical screening. Ground-mounted HVAC equipment, generators,
utility cabinets, loading/service facilities, and similar installations visible from any off-site location at
normal ground level shall be effectively screened by walls, fences, landscaping, topography, or other
durable methods. Screening shall be maintained and shall accommodate required access, ventilation, fire
protection, and utility safety. Screening materials need not always be brick.
(F) Rooftop mechanical equipment. Rooftop HVAC and other mechanical equipment shall be concealed
from normal ground-level views from public streets by parapets, screens, or architectural integration
compatible with the building. Screening is not required from every neighboring viewpoint or aerial
perspective.
(G) Rooftop solar. Solar panels and related rooftop collection equipment are exempt from architectural
screening requirements, including when visible from public streets, subject to applicable building, electrical,
fire, and designated historic-property requirements.
(H) Dumpster enclosures. Dumpster enclosure walls shall be constructed of the same approved primary
architectural material or materials used on the principal building. Gates may be made of durable opaque
complementary materials appropriate for service access and collection equipment; the gates need not be
masonry. Enclosures shall be functional and maintained.
(I) Architectural accent lighting. Uplighting of buildings, signs, flags, trees, landscaping, and architectural
features, including colored uplighting year-round, is permitted when aimed and shielded to limit glare, off-
site spill, and skyglow. Permanent exposed LED strips or tubing tracing entire rooflines, windows, building
edges, or architectural profiles are prohibited; concealed architectural accent lighting and temporary
holiday decorations are allowed. Flashing or strobing effects remain subject to other applicable regulations.
Sec. 155.502. General architectural design standards.
(A) Primary and accent facade materials
(1) Percentage and measurement. At least seventy percent (70%) of the opaque exterior wall area of each
prominent elevation shall consist of approved primary materials; no more than thirty percent (30%) may
consist of approved accent materials. A prominent elevation is one visible at normal ground level from a
public street or right-of-way, adjoining property, common open space, internal pedestrian area, or
similar off-site viewpoint. Windows, doors, and genuine openings are excluded from opaque wall-area
calculations. Fully concealed service elevations may use the simplified materials permitted in subsection
(B), without the 70/30 percentage, provided they are durably finished and effectively screened. No
mandatory minimum brick percentage applies.
(2) Approved primary materials. Primary materials include genuine full-depth fired-clay brick (including
anchored brick veneer and split-faced brick); genuine fired-clay thin-brick veneer installed as a durable
approved cladding; precast panels incorporating genuine brick; natural stone; appropriate cast-stone or
architecturally finished stone-like masonry; and fiber-cement or comparable cementitious siding in lap,
board, panel, or shingle profiles. A particular manufacturer or brand is not required.
Page 22 of 64
TOWN OF BLYTHEWOOD | BAR STANDARDS & PROCEDURES | WORKING DRAFT 04
Architectural and BAR procedure draft only | Not for adoption | November 11, 2026 | Page 5
(3) Approved accent materials. Up to thirty percent (30%) of a prominent elevation may use compatible
accent materials, including architectural split-faced or decorative concrete masonry units (CMU), high-
quality architectural metal panels, hard-coat stucco, properly detailed EIFS, ceramic or architectural tile,
wood detailing, glass block, and other durable architectural treatments approved under the review
procedures. Stucco and EIFS are not primary materials. Accent treatments shall be integrated with the
building and not used to disguise poor-quality construction.
(4) Prohibited and utilitarian materials. Faux or imitation brick panels do not qualify as genuine brick.
Conventional vinyl siding, conventional residential-style aluminum siding, exposed unfinished gray CMU,
and unarticulated industrial metal wall panels are prohibited as the principal finish of prominent
commercial elevations. Ordinary CMU or simpler durable metal cladding may be used on effectively
concealed service elevations and accessory buildings as expressly provided herein. Decorative
architectural CMU is permitted as an accent material. Split-faced brick is permitted as genuine brick.
(B) Four-sided architectural treatment
(1) Integrated design. Every building elevation shall be completed with durable finished materials and
shall relate coherently to the principal facade in color, scale, and architectural composition. The four-
sided architecture requirement does not mean four identical storefronts or equally elaborate detailing on
every wall.
(2) Visibility-sensitive detailing. Elevations visible at normal ground level from public rights-of-way,
adjoining properties, common spaces, and prominent pedestrian areas shall receive meaningful
architectural detailing and the primary-material treatment required above. Screened rear service
elevations may be simpler and may use ordinary finished CMU or other durable utilitarian materials
when effectively concealed from off-site views.
(3) Service elevations. Loading docks, utility access, service doors, and equipment may be concentrated on
side or rear elevations and screened appropriately. No false windows or decorative storefronts are
required solely to conceal operational needs.
(C) Facade articulation and building mass
(1) General. Large or monotonous walls shall be broken into a coherent visual composition using
meaningful architectural features, including wall-plane changes, pilasters, reveals, entries, windows,
canopies, awnings, materials, masonry patterns, parapet variation, or other comparable elements.
Decorative features shall be integrated into the design rather than applied mechanically.
(2) Articulation rhythm. Street-facing and other prominently visible facades shall generally exhibit
meaningful changes in architectural rhythm at intervals of approximately 50 feet. The source draft’s
mandatory two-foot offset at every 50 feet is eliminated; the BAR may accept alternative features
providing equivalent visual relief.
(3) Long facades. Prominent facades exceeding 100 feet shall use multiple complementary articulation
techniques. Facades exceeding 200 feet shall provide more substantial architectural composition changes
at intervals generally not exceeding 100 feet. No mandatory five-foot-deep recess, 20-foot-long projection,
or 20-to-40-percent formula is imposed.
(4) Visibility. The intensity of articulation shall correspond to actual visibility and building context.
Screened service elevations may be simpler, but may not remain raw or unfinished where the article
requires finished exterior walls.
Page 23 of 64
TOWN OF BLYTHEWOOD | BAR STANDARDS & PROCEDURES | WORKING DRAFT 04
Architectural and BAR procedure draft only | Not for adoption | November 11, 2026 | Page 6
(D) Rooflines
(1) Permitted forms. Pitched roofs are encouraged but not mandatory. Flat and low-slope roofs are
permitted with appropriate parapets, cornices, roofline changes, or comparable integrated architectural
treatment. No numerical 8:12-to-12:12 or 5:12-to-12:12 roof-pitch mandate applies.
(2) Roofing and drainage details. Durable, code-compliant roof coverings are permitted, including
shingles, standing-seam metal, slate, tile, and other suitable materials. Exposed gutters, downspouts, and
flashing shall be durable, properly installed, and finished to complement the building; particular metals
and identical gutter/downspout finishes are not mandatory. Rooftop mechanical equipment shall be
screened as provided in §155.501(F).
(3) False mansards. Applied false mansards that primarily disguise an otherwise unrelated roof or facade
are prohibited. Contemporary roof forms are not prohibited merely because they depart from traditional
pitched-roof architecture.
(E) Windows and storefront treatment
(1) Window design. Traditional divided-light and contemporary large undivided windows are permitted.
Windows shall be proportioned and arranged coherently for the building type. No universal requirement
for divided lights, one-over-one glazing, vertical window proportions, masonry sills, or a rigid grid
applies.
(2) Glazing and solar protection. Tinted, low-emissivity, UV-resistant, and other energy-efficient glazing
and retrofit films are permitted. Highly mirrored, highly reflective, or opaque-looking glass that makes
prominent windows appear blocked or blacked out is prohibited. No universal 60-percent or 88-percent
visible-light-transmission requirement or 0.20 reflectance cap is imposed. Appropriate privacy and
specialized interior conditions may justify alternatives as provided below.
(3) Main Street storefronts. Retail and restaurant frontages on Main Street/Wilson Boulevard shall include
substantial authentic street-facing storefront glazing. Required glazing shall maintain meaningful visual
transparency and shall not be substantially obscured by opaque films, paper, posters, coverings, or
window displays. Sign content and sign permitting remain governed by the sign ordinance. Reasonable
alternatives may be approved for legitimate privacy, security, or specialized operational needs.
(4) Other corridors and uses. Along Blythewood Road, McNulty Road/Extension, and Langford Road, use-
appropriate windows, entries, and facade design shall be provided without mandatory downtown-style
storefront glazing. Civic, medical, institutional, and residential uses may require different levels of
privacy and daylighting.
(5) Decorative windows. False windows and other decorative window treatments are permitted as optional
articulation, but are not mandatory and do not satisfy requirements for actual transparent storefront
glazing.
(F) Multistory composition and color
(1) Multistory composition. Traditional base/shaft/cap and two- or three-part facade treatments are
encouraged when appropriate, but contemporary or alternative coherent multistory compositions are
equally permissible. No mandatory floor-by-floor material division or rigid first/upper-floor height ratio
is created by these architectural standards.
(2) Exterior color. Bold, saturated, and corporate colors are permitted, including large applications of red,
turquoise, or other vivid colors when integrated into the facade design. The BAR may review major
Page 24 of 64
TOWN OF BLYTHEWOOD | BAR STANDARDS & PROCEDURES | WORKING DRAFT 04
Architectural and BAR procedure draft only | Not for adoption | November 11, 2026 | Page 7
exterior color changes for the relationship of color distribution to massing, trim, windows, rooflines, and
materials; findings shall identify specific architectural concerns, not dislike of a hue or brand.
Fluorescent, dayglow, and highly reflective finishes are prohibited. Like-for-like repainting is exempt;
minor trim changes may be approved administratively. Painting alone does not require architectural
retrofit of the building.
(G) Material transitions and architectural detailing
(1) Material transitions. Changes in exterior facade materials shall occur as intentional architectural
features at appropriate wall planes, corners, courses, openings, or other visually coherent locations.
Materials need not change exclusively horizontally or vertically, and heavier materials are not categorically
required below lighter materials. The conflicting Kendig Keast §2.03.01(J)(2) and (J)(3) restrictions are
eliminated.
(2) Foundations and cantilevers. Exposed foundations, columns, cantilevers, and other structural elements
shall be appropriately finished and integrated into the architectural design. No mandatory contrasting
foundation band, blanket prohibition on unsupported-appearing cantilevers, or fixed decorative column
dimensions is imposed by this article; applicable structural and building codes remain controlling.
(3) Shutters. Where shutters are used, they shall be appropriately sized and proportioned to the associated
windows and shall include visible hinges and holdback hardware, or architecturally appropriate
equivalents, whether functional or decorative. Shutters shall appear plausibly operable rather than as
narrow applied trim. The exact one-half-window-width requirement is removed.
(H) Awnings, canopies, and architectural projections
(1) Design and materials. Traditional fabric awnings and contemporary metal, glass, or other durable
canopies are permitted when proportioned and integrated with the building. Bold or corporate colors are
allowed under the color standard. Internally illuminated awnings that glow through the awning material are
prohibited; ordinary exterior illumination is permitted. Awnings shall be maintained free of torn fabric,
sagging, corrosion, and unsafe supports.
(2) Public rights-of-way. Awnings and canopies projecting over public sidewalks are encouraged where
appropriate, particularly on Main Street, but are not mandatory and require all applicable right-of-way
encroachment permissions, pedestrian clearance, accessibility, and safety approvals. BAR approval does not
confer a right-of-way permit.
(3) Signage. Logos, lettering, and advertising on awnings or canopies constitute signage and are governed
by the Town’s sign regulations rather than architectural approval of the message.
(I) Murals and existing masonry
(1) Murals. Within property otherwise subject to BAR jurisdiction, murals may be approved for their
architectural placement, scale, installation, materials, and relationship to the building. The BAR shall not
extend mural review townwide or regulate the viewpoint or message of an otherwise lawful mural.
Advertising and sign classifications remain governed by the sign ordinance.
(2) Unpainted brick and stone. Existing previously unpainted natural brick and natural stone masonry
shall retain its natural appearance. Painting, limewashing, whitewashing, staining, color-altering coatings, or
painting murals directly on such masonry are prohibited, whether or not the building is historic. Ordinary
appropriate cleaning, repointing, and clear treatments that do not alter appearance are permitted.
Previously painted masonry may be repainted under the color standards. Newly constructed buildings may
Page 25 of 64
TOWN OF BLYTHEWOOD | BAR STANDARDS & PROCEDURES | WORKING DRAFT 04
Architectural and BAR procedure draft only | Not for adoption | November 11, 2026 | Page 8
use painted brick as part of an approved design; once installed as unpainted masonry, it is subject to this
protection in subsequent alterations.
Sec. 155.503. Existing signage provision.
RESERVED. The existing §155.503 signage provision is not amended here. Architectural treatment of awnings,
murals, and storefront transparency does not give the BAR authority to approve or reject sign messages,
advertising content, or signage permits.
Sec. 155.504. Building-specific architectural standards.
(A) Commercial and mixed-use buildings
(1) General. Commercial and mixed-use buildings shall comply with the uniform primary/accent material
standards, four-sided architectural treatment, coherent facade articulation, flexible roofline standards,
and applicable frontage requirements in this article.
(2) Retail frontages. Main Street/Wilson Boulevard retail frontages shall emphasize authentic pedestrian-
oriented storefronts. On other enhanced corridors, the building’s use and auto-oriented context may
justify alternative window and entrance arrangements.
(B) Convenience stores and gasoline sales
(1) Principal building and canopy. Convenience stores shall meet the general commercial architectural
standards. Fuel canopies and accessory car wash structures shall have coordinated colors, rooflines,
fascia, trim, and compatible architectural materials. Canopies shall not present as unrelated structures.
(2) Fuel-canopy columns. Every exposed fuel-canopy support column shall be clad on all visible sides and
throughout its full exposed height with an approved primary architectural material compatible with the
principal building. Bare structural support poles are prohibited.
(3) Fascia, lighting, and signage. Canopy fascia shall be proportioned and architecturally integrated rather
than appearing as oversized illuminated plastic cladding. Brick fascia is not mandatory. Lighting shall be
integrated and controlled under applicable standards; canopy signage is governed separately by the sign
ordinance.
(4) Prominent corners. At prominent intersections along the four enhanced corridors, the principal store
building is preferred at the corner and the fuel canopy is preferred at the side or rear. The BAR may
approve an alternative where the building and canopy together create a comparably attractive
streetscape. This preference is especially strong on Main Street/Wilson Boulevard.
(5) Material calculation. The 70/30 opaque wall-area rule applies to the principal building and applicable
enclosed accessory buildings, not the overhead canopy fascia. Exposed canopy columns remain fully clad
as provided above.
(C) Restaurants, banks, pharmacies, and other drive-through uses
(1) Drive-through siting. Drive-through service windows, lanes, and queues shall be located at the side or
rear, never between the principal building and a public street. This is a binding requirement and is not
subject to a BAR waiver. Site engineering and stacking capacity remain governed by other applicable
ordinances.
Page 26 of 64
TOWN OF BLYTHEWOOD | BAR STANDARDS & PROCEDURES | WORKING DRAFT 04
Architectural and BAR procedure draft only | Not for adoption | November 11, 2026 | Page 9
(2) Architectural integration. Service windows, menu boards, canopies, and equipment shall be integrated
with the building and appropriately screened. The sign ordinance governs menu-board signs and
advertising.
(D) Car washes
(1) Entrance, exit, and queues. Car washes may have street-facing tunnel openings and front queuing
when lawful, with queues contained on the property. This express exception does not apply to
restaurants, banks, pharmacies, or other conventional drive-through uses.
(2) Architectural treatment. Car wash buildings shall meet the material and four-sided design
requirements for prominent elevations. Long walls may be articulated by pilasters, material patterns,
architectural metal accents, roofline variation, and other genuine design features; fake windows are not
mandatory.
(3) Landscaping coordination. Screening of queues, vacuum stations, and operational equipment shall be
addressed in the landscaping/site-development ordinance. BAR architectural approval does not substitute
for those standards.
(E) Civic buildings
(1) Equal treatment. Government buildings, houses of worship, libraries, schools, community facilities, and
other covered civic buildings shall meet the same 70-percent primary/30-percent accent standard for
prominent elevations. No separate 90-percent masonry or 10-percent accent-material standard applies.
(2) Civic expression. Distinctive civic elements, including steeples, stained glass, ceremonial entrances, and
contemporary institutional design, are permitted when coherent with the overall building architecture.
(F) Multifamily residential buildings
(1) Length and articulation. No absolute 200-foot maximum facade length is imposed on multifamily
buildings by these architectural standards. Longer buildings are permissible with meaningful
articulation and a coherent design proportionate to visibility from streets, adjoining properties, common
spaces, and pedestrian areas.
(2) Materials and roofs. The same 70/30 primary/accent framework and flexible pitched, flat, and low-slope
roof standards apply to multifamily buildings. No separate mandatory roof pitch, divided-light window
grid, or fixed upper-story glazing percentage applies.
(3) Private outdoor space. Each dwelling unit with direct exterior access shall have a usable private porch,
patio, or balcony integrated into the architecture. Front stoops are permitted as entrance elements, but a
small entry stoop alone does not replace required usable private outdoor space. No rigid 5-by-5-foot
porch, 12-inch raised-floor, or decorative column-dimension requirement applies.
(4) Interior-corridor buildings. For dwellings accessed through enclosed interior corridors, the BAR may
approve attractive shared or alternative outdoor amenities. Requirements shall not vary solely because
the building serves older adults, lower-income households, or another resident group.
(G) Single-family attached residential buildings (townhomes)
(1) Maximum attached units. A townhome building shall contain no more than six attached dwelling units.
Nominal breaks, token breezeways, or architectural devices shall not circumvent the six-unit limit.
Placement in the appropriate zoning dimensional provisions is required before adoption.
Page 27 of 64
TOWN OF BLYTHEWOOD | BAR STANDARDS & PROCEDURES | WORKING DRAFT 04
Architectural and BAR procedure draft only | Not for adoption | November 11, 2026 | Page 10
(2) Building length. A townhome building shall not exceed 150 feet along its principal frontage, subject to
final coordination with the applicable zoning dimensional provisions.
(3) Unit widths. Each attached unit shall be at least 20 feet wide, and the average unit width within each
building shall be at least 22 feet. Wider end units are encouraged but not mandatory. These dimensions
require zoning coordination before adoption.
(4) Side setbacks and separation. At the two exterior ends of each attached townhome building, a
minimum ten-foot side setback shall apply. Two separate townhome buildings placed end-to-end along
the same street shall therefore have a minimum 20-foot landscaped separation between building ends.
These are not rear-yard setback rules, and building/fire codes may require greater separation. Final
zoning placement is required.
(5) Landscaped gaps. The 20-foot separation between adjacent townhome building ends shall be
predominantly landscaped and pervious; paths, drainage, utilities, and stormwater features may be
accommodated. The separation shall remain a genuine open break, not a disguised extension of the
buildings.
Townhome plan view: two six-unit buildings aligned along the same street, with a 20-foot landscaped break between their
ends. Entrance orientation is not regulated by this diagram. Not to scale.
(6) Facade differentiation. Each adjacent attached unit shall have a visibly distinct architectural facade,
material treatment, and dominant color combination. Merely alternating paint color without changing
facade design is insufficient. Changes may include roof form, entry/porch treatment, window pattern,
material placement, and building composition.
(7) Development-wide variation. Each six-unit row shall present six distinct facade/material/color
combinations. A development with twelve or more townhomes shall provide at least twelve distinct
combinations, distributed to avoid monotonous repetition. Opposing rows shall not simply mirror
identical six-unit sequences.
(8) Facade schedule. The applicant shall submit a plan or schedule identifying each facade combination
and its location, materials, and dominant colors. Combinations may be repeated in larger developments
when sufficiently dispersed.
(9) Garages. Front-facing garages are permitted when subordinate to the residence’s overall facade. Single-
width doors are encouraged but not required; two-car doors are permitted when thoughtfully integrated
with entries, porches, windows, setbacks, and detailing.
Page 28 of 64
TOWN OF BLYTHEWOOD | BAR STANDARDS & PROCEDURES | WORKING DRAFT 04
Architectural and BAR procedure draft only | Not for adoption | November 11, 2026 | Page 11
(10) No architectural minimum floor area. These architectural standards do not impose a minimum
townhome floor area. Kendig Keast’s 2,000-square-foot per-unit coverage limit and four-corner facade
rule are removed; existing zoning lot-coverage requirements continue unless separately amended.
DRAFTING NOTE | ZONING COORDINATION ONLY. The six-unit cap, 150-foot length, 20-foot minimum unit
width, 22-foot average unit width, and 10-foot exterior side setbacks/20-foot end-to-end building separation are
agreed policy directions, but must be placed or cross-referenced in the correct existing zoning provisions. The
illustration shows two six-unit buildings along one street; no 15-foot rear setback has been adopted in this
working review.
(H) Detached accessory buildings and ancillary structures
(1) Visible accessory buildings. Detached accessory buildings serving covered commercial, mixed-use,
multifamily, or civic properties and visible at normal ground level from a public street, adjoining property,
or other off-site location shall be architecturally compatible with the principal building in materials, colors,
finishes, and design. Prominent accessory elevations shall comply with applicable material standards.
(2) Concealed accessory buildings. Where placement, vegetation, fences, walls, or topography effectively
conceal a detached accessory building from off-site ground-level views, simpler durable materials, including
metal siding or panels, may be permitted. Required screening shall be maintained. Visibility, rather than the
mere fact that the structure is accessory, governs the architectural treatment.
(3) Containers and land use. Whether intermodal shipping containers or portable storage units may be
placed on a property is a land-use and accessory-structure issue under the zoning ordinance, not a matter of
BAR architectural approval. No new container-use rule is created in this architectural draft.
Sec. 155.505. Additions, renovations, and existing buildings.
(A) General rule. New additions and altered portions of existing covered buildings shall comply with applicable
architectural standards and form a cohesive design with the existing structure. An addition does not automatically
require an otherwise lawful, unaltered building to be completely reclad or reconstructed.
Page 29 of 64
TOWN OF BLYTHEWOOD | BAR STANDARDS & PROCEDURES | WORKING DRAFT 04
Architectural and BAR procedure draft only | Not for adoption | November 11, 2026 | Page 12
(B) Architectural compatibility of additions. Additions should generally respect the existing building’s
architectural style, materials, proportions, roofline, and detailing. A contemporary addition may be
approved when its massing, scale, materials, and transitions thoughtfully complement the original building.
Matching historic details exactly is not universally required.
(C) Elevation threshold. If 50 percent or more of the gross exterior wall area of an individual elevation is
substantially reconstructed, reclad, or replaced, cumulatively during any consecutive five-year period, the
entire affected elevation shall comply with the applicable current architectural and material standards.
(D) Whole-building threshold. If 50 percent or more of the total gross exterior wall area of a covered
building is substantially reconstructed, reclad, or replaced, cumulatively during any consecutive five-year
period, all exterior elevations of the building shall comply with the applicable current architectural
standards. Already compliant elements need not be needlessly replaced.
(E) Measurement and work counted. Thresholds are measured by gross exterior wall area, excluding
roofs. Substantial reconstruction, removal and replacement of cladding, and wholesale replacement with
identical previously nonconforming materials count toward the threshold. Projects shall not be segmented to
evade the cumulative five-year calculation.
(F) Work excluded. Ordinary maintenance, limited repairs, repainting, direct replacement or energy-
efficient upgrading of windows in existing openings, and interior, plumbing, electrical, or mechanical work
that does not substantially alter exterior wall construction do not count toward the 50-percent facade
threshold. Major color changes may still require limited architectural color review, without triggering
whole-building retrofit.
(G) Casualty damage. Exterior reconstruction following fire, storms, accidents, or other involuntary
damage is subject to the same facade-area thresholds, with emergency stabilization permitted. Applicable
nonconforming-structure, floodplain, building, and life-safety requirements remain independently
controlling and must be reconciled before adoption.
(H) Existing natural masonry. Renovation of existing unpainted brick or stone shall comply with the
masonry protection standard in §155.502(I)(2), whether or not the structure is individually designated
historic.
(I) Existing nonconforming design. A lawfully existing building is not required to comply with new
architectural standards solely because this article is adopted. Compliance is required for qualifying new
work and upon the applicable alteration thresholds, subject to final coordination with existing
nonconforming provisions.
PART II | HISTORIC-PRESERVATION COORDINATING PROVISIONS
SEPARATE EXISTING CHAPTER. The following records agreed policy directions for designated historic properties
and demolition/relocation. These provisions belong in or alongside the existing historic-preservation subchapter,
not as a blanket expansion of ordinary BAR architectural jurisdiction. They require Town Attorney review before
use as ordinance text.
(A) Nonhistoric demolition
(1) No BAR demolition approval. Demolition of a building that is not individually designated historic and is
not otherwise protected by a lawfully established historic designation does not require a BAR demolition
approval, regardless of age, structural soundness, or whether a replacement development is proposed. All
Page 30 of 64
TOWN OF BLYTHEWOOD | BAR STANDARDS & PROCEDURES | WORKING DRAFT 04
Architectural and BAR procedure draft only | Not for adoption | November 11, 2026 | Page 13
applicable demolition permits, utility disconnections, safety controls, and site stabilization requirements
remain in effect. New replacement construction remains subject to applicable BAR architectural review.
(B) Designated historic demolition and economic hardship
(1) Objective threshold. For a designated historic building, substantial economic hardship sufficient for
demolition approval is demonstrated when the reasonable documented cost to rehabilitate the building to a
safe, lawful, occupiable condition exceeds 50 percent of the Richland County Assessor’s most recent
appraised value of the building improvements alone, excluding land. The comparison shall not use fair
market value of the entire property or the taxable assessed value.
(2) Documentation. The applicant shall submit a qualified professional’s condition assessment and an
itemized rehabilitation cost estimate. The BAR may verify the information and request reasonably necessary
supporting records.
(3) Decision. Upon adequate proof of the stated hardship threshold, the BAR shall approve demolition
unless it makes supported findings of demolition by neglect under subsection (C), or another controlling life-
safety or historic-preservation law requires a different result. Final legal drafting shall reconcile this rule
with existing §155.543.
(C) Demolition by neglect
(1) Disqualification. The BAR may deny demolition of a designated historic building despite satisfaction of
the hardship threshold where substantial deterioration is attributable to the owner’s prolonged failure to
perform reasonable maintenance or repairs. A prior formal property-maintenance citation is not required.
The BAR shall rely on substantial evidence, including photographs, inspections, maintenance history, known
defects, and the owner’s period of control, and shall provide written findings and an opportunity for the
owner to respond. Age, vacancy, or deterioration predating ownership alone is insufficient.
(2) Safety authority. Nothing in this provision limits the building official’s authority to address an
imminently dangerous or unsafe structure under applicable law.
(D) Documentation before historic demolition
(1) Archival record. Before issuance of a demolition permit for a designated historic building, the owner
shall provide digital photographs of all reasonably accessible exterior elevations and significant
architectural details for permanent Town archival retention. Existing historic plans or photographs readily
available to the owner may be requested. A costly professional measured-drawing survey is not routinely
required.
(E) Relocation of designated historic buildings
(1) Relocation permitted. The BAR may approve relocation of a designated historic building when the
proposal reasonably preserves the structure and includes a credible destination, relocation method, and
protection measures. Relocation may be approved to a site outside Town limits; preservation within the
Town is not a mandatory preference or condition. The original parcel may thereafter be redeveloped under
applicable zoning and architectural standards.
(2) Responsible execution. A relocation plan shall identify the destination, transport route and measures,
qualified insured mover, and required transportation, safety, and building approvals. Accidental transit
damage is not automatically an ordinance violation; intentional or reckless destruction is not authorized by
a relocation approval. No special performance bond is required solely by this architectural policy.
Page 31 of 64
TOWN OF BLYTHEWOOD | BAR STANDARDS & PROCEDURES | WORKING DRAFT 04
Architectural and BAR procedure draft only | Not for adoption | November 11, 2026 | Page 14
(F) Historic architectural review
(1) Compatibility. Alterations and additions to designated historic properties shall be reviewed under the
applicable historic-preservation criteria and the adopted designation. Contemporary compatible additions
may be considered where they do not destroy significant historic fabric. Historic jurisdiction is not created
merely by a building’s age or architectural appearance.
Page 32 of 64
TOWN OF BLYTHEWOOD | BAR STANDARDS & PROCEDURES | WORKING DRAFT 04
Architectural and BAR procedure draft only | Not for adoption | November 11, 2026 | Page 15
PART III | PROPOSED BAR ADMINISTRATION AND PROCEDURES
DRAFTING NOTE | PROVISIONAL SECTION NUMBERS. These sections consolidate the Town Manager’s procedural
decisions. They are subject to legal review, especially statutory hearing notice, written findings following failed
approval motions, appeal periods, reconsideration limits, and the Town’s currently adopted BAR provisions.
Sec. 155.506. Certificates of Appropriateness and levels of review.
(A) General requirement. For development subject to this article, a Certificate of Appropriateness (COA)
shall be obtained before a zoning or building permit authorizing regulated exterior construction or
alteration is issued. Review is limited to architectural matters within the Town’s lawful jurisdiction. Neither
the dollar value of the work nor a fixed construction-cost threshold determines the level of architectural
review.
(B) Work exempt from architectural approval. Ordinary maintenance and repairs that do not materially
change an exterior architectural appearance are exempt from COA review, including repainting in an
existing approved color scheme; replacement of roofing, windows, doors, and exterior components with like-
for-like materials, configuration, and appearance; routine cleaning and upkeep; and comparable
nonmaterial work. Work otherwise requiring building, zoning, historic-preservation, or other permits
remains subject to those requirements. The exemption does not authorize painting, washing, or staining
previously unpainted natural masonry in violation of this article.
(C) Administrative architectural approval. The Planning Official may issue a COA administratively for
objectively compliant minor exterior changes, including modest facade alterations, replacement awnings,
small accessory buildings, minor changes in materials or color, and other limited work that does not
materially alter the approved architectural composition. Administrative approval shall be based on the
adopted standards, not solely on subjective design preference. The Town Architect may be consulted when
professional evaluation is reasonably necessary.
(D) Referral to the BAR. The Planning Official may refer any administratively eligible application to the
Board of Architectural Review for original review, without first denying the application. Such referral is not
an administrative appeal and shall not itself create an additional applicant fee beyond the Town’s otherwise
applicable review charges.
(E) Formal BAR approval. The BAR shall consider new principal buildings, substantial additions, major
facade renovations, significant changes in architectural form or color, requests for architectural alternatives,
matters requiring BAR action under the historic-preservation regulations, and other applications not eligible
for administrative approval. Administrative approval shall not be used to circumvent an express condition
of a prior BAR approval.
(F) Timely administrative action. Administrative applications shall be processed upon receipt of a
complete submission and verification of compliance, without waiting for a monthly BAR application
deadline or meeting date.
Sec. 155.507. Application, completeness, and scheduling.
(A) Application materials. An application shall be submitted to the Planning Official on Town forms and
shall include, as reasonably applicable: scaled exterior elevations; plans showing the affected building and
site relationships; proposed materials, textures, and colors; existing-condition and adjoining-context
Page 33 of 64
TOWN OF BLYTHEWOOD | BAR STANDARDS & PROCEDURES | WORKING DRAFT 04
Architectural and BAR procedure draft only | Not for adoption | November 11, 2026 | Page 16
photographs; and other information reasonably needed to evaluate compliance with the architectural
standards. Materials unrelated to the scope of proposed work shall not be demanded merely as a formality.
(B) Formal BAR submission deadline. Applications for formal BAR consideration shall be submitted at
least one calendar month before the regularly scheduled meeting at which consideration is requested. The
Planning Official may, at the Planning Official’s discretion, accept a later submission for consideration at an
earlier meeting when sufficient time exists for completeness review and any required professional review.
Timely submission does not guarantee placement on a particular meeting agenda. The Planning Official shall
determine completeness, coordinate professional review, and advise the applicant of material deficiencies or
missing information.
(C) Administrative processing target. The Town should ordinarily seek to place a complete application
before the BAR within approximately sixty (60) days after the applicable application deadline, allowing time
for staff review, Town Architect recommendations, and reasonable applicant revisions. This is an
administrative target, not an automatic-approval deadline or a guarantee of a particular hearing date.
(D) Right to formal consideration. After the applicant has submitted a complete application and the
required professional review has been performed, the applicant may request formal BAR consideration even
when the Town Architect or Planning Official recommends against approval. Staff and consultants shall not
indefinitely delay a hearing to obtain design changes the applicant does not wish to make.
(E) Applicant preparation. The applicant remains responsible for the design and completeness of the
proposed project. Town review is not a substitute for the applicant’s architect, engineer, or other design
professional.
Sec. 155.508. Town Architect, professional review, and informal work
sessions.
(A) Independent advisory role. The Town may retain an architect or other qualified design professional to
review applications on the Town’s behalf. The Town Architect serves as an independent technical advisor to
staff and the BAR, not as the applicant’s designer or a voting member. The BAR is not bound by the
architect’s recommendation; a decision differing from that recommendation shall be supported by findings
under the applicable ordinance standards.
(B) Scope and prepayment. Before commencing applicant-funded professional review, the Town Architect
shall provide a written scope and cost estimate through the Town. The applicant shall pay the quoted
amount to the Town in advance. The Town shall direct and pay the architect, reconcile actual reasonable
charges, refund any unused balance, and obtain a supplemental estimate and prepayment when additional
professional review is reasonably necessary. No fixed professional-review amount is established by this
article; applicable charges shall be administered through the Town’s adopted fee schedule and actual-cost
procedures.
(C) Repeated review and disclosure. Additional staff and Town Architect review may occur when
reasonably necessary to evaluate revisions. Reasonable additional professional-review costs are borne by the
applicant, but review shall not be used to prevent the applicant from obtaining a formal BAR decision after
required review. The architect’s written recommendation shall be made available to the applicant before the
BAR hearing.
(D) Attendance. The Town Architect is expected to attend formal BAR meetings unless the Planning Official
advises that attendance is unnecessary. Applicant-funded meeting time shall be reasonably attributable to
Page 34 of 64
TOWN OF BLYTHEWOOD | BAR STANDARDS & PROCEDURES | WORKING DRAFT 04
Architectural and BAR procedure draft only | Not for adoption | November 11, 2026 | Page 17
that applicant’s review. Time spent on unrelated agenda matters or general Board service shall not be
charged to a particular applicant; such time shall be paid by the Town as appropriate.
(E) Optional informal work sessions. The applicant or Planning Official may request an informal BAR
work session before formal action. Participation is voluntary. No more than two (2) informal BAR work
sessions shall be held for the same or substantially similar proposal, regardless of withdrawal or
resubmission. Work sessions shall be properly noticed and open as required by law; no binding decision,
formal approval, or vote on the application may occur.
Sec. 155.509. BAR meetings, hearings, votes, and written findings.
(A) Membership and quorum. The Board consists of five (5) Town residents appointed by Town Council in
accordance with the Town’s currently adopted BAR membership and organizational provisions. Three (3)
members eligible to participate in the matter constitute a quorum. A recused member shall not count toward
the quorum for that application. The Chairperson votes as a regular member. Final action requires the
affirmative vote of a majority of the members present and eligible to vote. Terms, officers, appointments, and
vacancies shall be governed by the Town’s adopted provisions, as reconciled by ordinance.
(B) Meeting calendar and special meetings. The BAR shall establish an annual regular meeting schedule.
The Chairperson, in consultation with the Planning Official, may reschedule regular meetings or call special
meetings to accommodate holidays, staff availability, workload, or other practical circumstances, subject to
required notice and a quorum. An applicant has no right to demand a special meeting.
(C) Notice and participation. The Town shall provide notice of all public meetings in accordance with
applicable state law, including the posting of agendas and meeting schedules. Meetings of the Board shall be
open to the public as required by law. Public attendance does not create a general right to address the Board
concerning an architectural application. The applicant or authorized representative may address the Board,
but attendance is not mandatory and the BAR may decide a scheduled application in the applicant’s absence.
Persons legally entitled to notice or participation in a particular proceeding shall be afforded those rights.
The Chairperson may impose reasonable, evenhanded time and order rules. Any additional notice required
by an applicable Town ordinance remains in effect until lawfully amended.
(D) Substantive communications outside meetings. Members should refrain from substantive discussions
concerning pending applications outside duly noticed proceedings. Any substantive outside communication
received concerning a pending application shall be disclosed on the record before action, with a reasonable
opportunity to address material information as required by law.
(E) Permitted decisions and motions. The BAR may approve an application as submitted or approve it
with specific, measurable conditions that are consistent with the ordinance and capable of verification by
staff or the Town Architect. Motions on the merits shall be motions to approve, with or without stated
conditions; a separate motion to deny is not required or permitted. If a motion for approval does not receive
the required affirmative majority, including because of a tie vote, the application is denied.
(F) Deliberation and findings. Before the vote, the Chairperson shall invite members to identify material
concerns and the applicable ordinance standards, allowing the applicant a reasonable opportunity to
respond. Following a failed approval motion, the Chairperson shall request that members voting against
approval state the particular standards and factual reasons supporting their votes. Those reasons shall be
recorded contemporaneously. The Town shall not attribute a common finding to a majority when the
members did not actually agree on that finding, and staff shall not later invent grounds not stated on the
record.
Page 35 of 64
TOWN OF BLYTHEWOOD | BAR STANDARDS & PROCEDURES | WORKING DRAFT 04
Architectural and BAR procedure draft only | Not for adoption | November 11, 2026 | Page 18
(G) Written decision. The BAR makes its decision by vote at the meeting, subject to stated conditions and
controlling law. The Planning Official shall prepare and provide the applicant with a written record of the
Board’s action within thirty (30) calendar days after the meeting. The written record shall state the result,
any approval conditions, the reasons for denial actually stated on the hearing record, and available appeal
information. The written record documents the Board’s action and shall not depend upon approval of the
next meeting’s minutes. The minutes shall identify each participating member’s vote and the reasons stated
for the action. The legal effective date and appeal period shall be governed by controlling law.
(H) Rescheduling, continuance, and quorum failure. The applicant may request rescheduling at any time
before the Chairperson calls that application for formal hearing. Once the formal hearing begins, a
withdrawal is treated as a heard application for purposes of reconsideration. The BAR may grant one
continuance of an application to a specified later meeting. If recusals or absence leave fewer than three
eligible members, the matter shall be rescheduled without charging the applicant with a continuance or
treating the matter as denied.
Sec. 155.510. Architectural alternatives and approval conditions.
(A) Equivalent or superior alternatives. The BAR may approve an architectural alternative that
substantially achieves the purposes and design objectives of this article through an equivalent or superior
design solution. Approval shall be supported by written findings explaining how the alternative meets those
objectives.
(B) Nonwaivable standards. Architectural alternatives shall not waive or vary an express mandatory
prohibition, numeric limit, dimensional requirement, or other standard for which the ordinance provides no
discretionary relief. Examples include the 70-percent primary-material requirement, the six-attached-unit
townhome limit, and the prohibition on conventional drive-through lanes and queues between a principal
building and a public street.
(C) Conditions. Conditions of approval shall be specific, objectively verifiable, and reasonably related to the
standards under review. A condition may require staff or Town Architect verification of identified details,
but shall not delegate a wholly new discretionary architectural decision to staff after the hearing.
Sec. 155.511. Reconsideration, withdrawal, and appeals.
(A) Revised submission after denial. An applicant may submit revised plans immediately following a
denial or a withdrawal after the formal hearing has begun. A request to reconsider the same or a
substantially similar proposal may be heard no earlier than the second regularly scheduled BAR meeting
following the original hearing. For example, a January hearing permits reconsideration no earlier than the
March regular meeting, assuming monthly meetings.
(B) Single reconsideration. Only one formal reconsideration of the same or substantially similar proposal
shall be allowed. If that reconsideration is denied, or the application is withdrawn after its formal hearing
begins, a further application for the same or substantially similar proposal shall not be heard for three
hundred sixty (360) calendar days following the final reconsideration action. A materially different proposal
and any rights preserved by applicable law shall be evaluated separately. This subsection requires Town
Attorney review before adoption.
(C) Administrative appeals. An actual final administrative architectural decision may be appealed to the
BAR within the time and in the manner prescribed by controlling state law and the Town’s applicable appeal
Page 36 of 64
TOWN OF BLYTHEWOOD | BAR STANDARDS & PROCEDURES | WORKING DRAFT 04
Architectural and BAR procedure draft only | Not for adoption | November 11, 2026 | Page 19
provisions. A Planning Official’s referral of an application for original BAR review is not an administrative
appeal.
(D) Judicial review. A final BAR decision is subject to judicial review in the Circuit Court as provided by
South Carolina law. No appeal to Town Council is created by this article. Statutory appeal rights and
deadlines shall control over any inconsistent administrative practice.
(E) Effect of repeat-application limit on judicial review. The 360-day restriction in subsection (B) applies
only to submission of the same or substantially similar application to the BAR. Nothing in that restriction
shall limit, prohibit, extend, or otherwise affect the right to seek judicial review in Circuit Court as provided
by law. The restriction shall not prevent proceedings required by a court order.
(F) No automatic approval by lapse of time. Except to the extent expressly required by controlling state
law, no application for a Certificate of Appropriateness, administrative architectural review, or BAR
consideration shall be deemed approved solely because a review period, scheduling target, or administrative
deadline has expired. An applicant may request formal BAR consideration after a complete application and
required professional review, as provided in §155.507(D).
Sec. 155.512. COA validity, project transfer, modifications, and records.
(A) Twenty-four-month permit period. For approved work requiring a building permit, a COA shall expire
if a building permit for the approved work is not issued within twenty-four (24) months after COA approval.
Where Planning Commission approval is required for the project, the twenty-four-month period shall begin
upon that approval. Issuance, not commencement of construction, is the event that satisfies this provision.
(B) Permit-linked validity. After issuance of a building permit for the approved work, the COA remains
valid for the life of that permit, including lawful renewals and extensions, and expires when the associated
permit expires or is revoked. No separate architectural inactivity or renewal schedule is established by this
article.
(C) Approved work not requiring a building permit. For work that does not require a building permit, a
COA shall remain valid for twenty-four (24) months from the date of approval. If the approved work begins
within that period, the certificate remains valid for completion of the approved work. Ordinary maintenance
and like-for-like work exempt from COA review under §155.506(A) require no certificate or renewal.
(D) Project-based approval. A COA attaches to the approved project and plans, not to the identity of the
applicant or property owner. Transfer of ownership does not require a new BAR hearing so long as the
approved design, conditions, and validity period remain unchanged.
(E) Minor approved-plan modifications. Minor modifications to previously approved plans may be
approved administratively only upon concurrence of both the Planning Official and Town Architect,
provided the changes comply with applicable standards and do not conflict with an express BAR condition.
Substantial design changes or changes lacking the required concurrence may be submitted to the BAR.
(F) Limit on modification hearings. No more than one (1) formal BAR hearing on modifications to the
same approved project may occur during any rolling twelve-month period, measured from the date of the
preceding modification hearing. This limit does not prevent ordinary administrative consideration of eligible
minor changes or the exercise of legally protected appeal rights.
(G) Official approval record. The Planning Official shall maintain the controlling approved plan set and a
complete project record containing the COA, Board findings, conditions, approved plans, and subsequent
authorized modifications. That record shall govern later permit coordination, construction review, and
verification of compliance.
Page 37 of 64
TOWN OF BLYTHEWOOD | BAR STANDARDS & PROCEDURES | WORKING DRAFT 04
Architectural and BAR procedure draft only | Not for adoption | November 11, 2026 | Page 20
Sec. 155.513. Permit coordination, enforcement, occupancy, and
emergency work.
(A) Building Department transmission. Upon issuance of a COA, the Planning Official shall transmit the
certificate, controlling approved plans, conditions, and subsequent approved modifications to the Building
Department or the Town’s designated inspection provider. Building permit review and inspections shall be
coordinated with the approved architectural documents.
(B) Construction compliance and enforcement. Construction shall conform to the approved COA and
authorized modifications. The Planning Official may pursue violations through existing Town zoning,
permitting, and enforcement procedures without referring each violation back to the BAR. Installation of
unauthorized materials or design elements does not itself confer approval. An owner may seek a
modification through the established procedure, but must otherwise correct the deviation.
(C) Final Certificate of Occupancy. Before issuance of a final Certificate of Occupancy for a project subject
to a COA, the Planning Official shall verify substantial conformity of the completed exterior with the
approved plans and conditions and provide written confirmation to the Building Department. The Building
Department shall obtain that confirmation before issuing the final Certificate of Occupancy.
(D) Temporary occupancy. The Building Official retains discretion to issue a Temporary Certificate of
Occupancy in accordance with applicable building and safety law. The Planning Official shall communicate
outstanding architectural deficiencies to the Building Official, but this article does not create an independent
architectural prohibition on otherwise lawful temporary occupancy.
(E) Emergency stabilization and temporary protection. Immediate temporary work reasonably
necessary to secure or stabilize a storm-, fire-, accident-, or otherwise damaged structure, including
temporary boarding, tarping, shoring, and comparable protective measures, may proceed without prior BAR
approval, subject to building and life-safety requirements. Permanent reconstruction or material
architectural changes remain subject to applicable COA procedures and the existing-building standards of
this article.
PART IV | ARCHITECTURAL DECISION REGISTER
This register documents the working policy decisions and departures from Kendig Keast. The operative
proposed text is in Parts I, II, and III; any inconsistency should be corrected before adoption. This register is
not ordinance language.
Applicability. Retain existing Town zoning district framework, not KK’s proposed districts. Cover TC, four
named enhanced corridors, and other commercially zoned or commercially used properties; exempt single-
family detached residences used residentially, except separate historic rules.
Primary/accent materials. 70/30 on prominent opaque elevations, not 90% masonry. Genuine thin brick
and split-faced brick primary; natural/cast stone and fiber cement primary. Architectural metal and
decorative CMU accent; ordinary gray CMU on effectively concealed service walls. No faux brick or
conventional aluminum/vinyl primary frontage siding.
Site orientation. Main Street pedestrian emphasis; auto-oriented parking permitted on the other three
enhanced corridors. Conventional drive-through lanes and queues cannot sit between building and public
street; car wash front-queue exception.
Page 38 of 64
TOWN OF BLYTHEWOOD | BAR STANDARDS & PROCEDURES | WORKING DRAFT 04
Architectural and BAR procedure draft only | Not for adoption | November 11, 2026 | Page 21
Four-sided architecture. Compatible, finished elevations on all sides; stronger treatment where visible
offsite; simple durable materials permitted on effectively concealed service elevations and accessory
buildings.
Articulation and material transitions. Meaningful ~50-foot rhythm and stronger ~100-foot treatment on
long prominent facades, with alternative design features. Remove mandatory 2-foot/5-foot wall offsets, rigid
material-change directions, and heavier-below-lighter rule.
Roofs and drainage. Pitched and well-designed flat/low-slope roofs permitted; no fixed pitch. False
mansards prohibited. Durable, visually compatible gutters, downspouts, and flashing without mandatory
metals.
Windows and solar control. Traditional and undivided contemporary windows permitted. Energy-efficient
tint and UV coatings allowed; no mirrored or blacked-out prominent glazing. No universal 60/88%
transmission mandate. Posters/opaque coverings may not substantially obscure required storefront glass.
Storefronts and colors. Main Street retail/restaurant glazing should be meaningful; other corridors use-
appropriate. Bold corporate colors allowed with architectural color distribution review, not personal hue
preferences. Dayglow/fluorescent/highly reflective finishes prohibited.
Gas stations. Compatible canopies; all exposed canopy columns clad full height in primary materials;
prominent-corner store preferred, alternative allowed. Fascia proportionate, no giant plastic illuminated
look.
Lighting, screening, and solar. Colored architectural uplighting permitted with glare control; permanent
exposed LED outline strips prohibited. Ground equipment screened from offsite views, rooftop HVAC from
street views, rooftop solar exempt. Dumpster walls match principal primary materials.
Murals and masonry. Murals reviewed architecturally only within BAR jurisdiction; content/signage
separate. Do not paint, limewash, stain, or mural over existing unpainted natural brick/stone; painted new
brick allowed as approved construction.
Civic and multifamily. Same 70/30 materials, no mandatory civic 90/10. Multifamily may exceed 200 feet
with articulation. Exterior-access units need usable private outdoor space; interior-corridor buildings may
use alternatives; stoops permitted.
Townhome form. Six units per attached building, maximum 150-foot frontage, at least 20-foot unit width
and 22-foot building average, 10-foot side setbacks at building ends and 20-foot landscaped end-to-end
separation; zoning placement required. No minimum dwelling floor area.
Townhome facades. Adjacent units distinct in architecture, materials, and dominant color; six distinct
combinations per six-unit row and at least twelve across developments of twelve or more; front garages
permitted but subordinate.
Fences and accessory buildings. Decorative commercial fencing must be attractive; columns encouraged
but not mandated every 30 feet. Visible accessory structures compatible; concealed metal accessory
buildings allowed. Shipping-container uses belong to general zoning, not BAR.
Additions and renovations. Compatible additions with contemporary options. Cumulative 50% of
individual elevation or whole-building exterior wall area within five years triggers compliance for the
affected elevation or whole exterior, respectively. Routine maintenance, repainting, window replacement,
and interior work exempt from that threshold. Casualty work counts.
Historic buildings. Nonhistoric demolition outside BAR demolition review. Historic hardship when
documented rehabilitation cost exceeds 50% of county appraised building improvement value, excluding
Page 39 of 64
TOWN OF BLYTHEWOOD | BAR STANDARDS & PROCEDURES | WORKING DRAFT 04
Architectural and BAR procedure draft only | Not for adoption | November 11, 2026 | Page 22
land; demolition by neglect may disqualify. Archive exterior photos; relocation allowed even beyond Town
limits.
Shutters, awnings, and chimneys. Shutters proportionate with visible hinges and holdbacks, functional or
decorative. Traditional/contemporary awnings allowed, maintained, not internally illuminated. Chimneys
may use approved building-compatible materials, not only full-depth brick or stone.
COA validity and procedure. COA valid 24 months before issuance of building permit, then follows valid
permit and renewals. BAR hearing and staff delegation procedures remain for next drafting phase; major
applications go to citizen BAR, with technical architect review.
Page 40 of 64
TOWN OF BLYTHEWOOD | BAR STANDARDS & PROCEDURES | WORKING DRAFT 04
Architectural and BAR procedure draft only | Not for adoption | November 11, 2026 | Page 23
Lighting and painting details. Major building color changes may receive BAR review; minor trim changes
administrative and like-for-like repaint exempt. LED strips outlining commercial buildings permanently
prohibited; colored architectural uplighting permitted with appropriate aiming and shielding.
Architecture cleanup. Remove rigid mandatory two/three-part facade, numeric floor heights, upper-floor
window percentages, fixed window sills, cantilever ban, foundation contrast, and contradictory SC/AU facade
material direction rules. Retain coherent design standards.
BAR review structure. No dollar threshold; ordinary maintenance exempt; staff handles objectively
compliant minor changes and may refer them to BAR; major new construction and significant architectural
changes receive formal BAR review.
Town Architect and review fees. Architect advises rather than controls BAR action; applicant prepays Town-
quoted professional-review costs through the Town, with reconciliation, refunds, and supplemental review
charges. Architect ordinarily attends BAR hearings unless excused by Planning Official.
Hearing and decision process. Five Town-resident members; three-member quorum; affirmative majority
required; approval motions only; a failed approval motion constitutes denial. Reasons for a failed approval
vote stated on record; written record provided to applicant within 30 calendar days without waiting for
minute approval. Applicant attendance optional. Public meeting attendance does not confer a general right
to speak; any legally required hearing rights remain protected.
Application timing and reconsideration. Mandatory one-calendar-month submission deadline for requested
regular BAR meeting, with Planning Official discretion to accommodate later submissions; approximately 60-
day nonbinding target; applicant may insist on formal hearing after required review. Maximum two
optional work sessions, one reconsideration no earlier than second subsequent regular meeting, and 360-day
similar-application restriction after failed reconsideration; judicial review and court-ordered remands
unaffected.
Postapproval administration. COA follows project and building permit; nonpermit work has a 24-month
commencement period. Planning Official and Town Architect jointly approve minor modifications; one BAR
modification hearing per rolling 12 months; approved plans transmitted to Building Department; Planning
Official signs off before final CO; Building Official may issue lawful TCO; emergency stabilization exempt
from prior BAR review.
PART V | LEGAL AND CODIFICATION REVIEW ITEMS
Architectural and procedural policy is now consolidated in Parts I–III. The following are specific legal,
technical, and codification checks, not invitations to reopen settled design choices. Town Attorney review is
essential before an ordinance is introduced.
1. BAR procedure legal review. Confirm approval-only motions, denial after a failed approval vote, reasons
recorded after the vote, majority/quorum rules, public meeting versus legally required hearing
participation, the vote’s legal effective date, and delivery of a written record within 30 calendar days.
Reconcile adopted §§155.497–155.498 appeal provisions and the existing 45-day deemed-approval clause;
the proposed policy rejects automatic approval unless controlling state law requires it.
2. Geographic coverage. Translate the agreed TC / four-corridor / commercially zoned-or-used framework
into enforceable text and, if needed, a map using current zoning districts (NO, NC, MO, MC, TC, CC and
commercial PD uses), without adopting Kendig Keast’s proposed SC/AU/MU/etc. district system. Preserve
the detached residential-use exemption and separate designated historic rules.
Page 41 of 64
TOWN OF BLYTHEWOOD | BAR STANDARDS & PROCEDURES | WORKING DRAFT 04
Architectural and BAR procedure draft only | Not for adoption | November 11, 2026 | Page 24
3. Existing code numbering and authority. Reconcile provisional §§155.499–155.513 with adopted §§155.315–
155.316, §§155.495–155.505, historic §§155.535–155.544, sign provisions, and the Town’s reportedly
adopted five-member BAR amendment. Verify the actual adopted five-member text and Town residency
requirement; do not reintroduce KK’s seven-member composition or rigid recruitment calendar.
Preserve otherwise applicable appointment, term, officer, and vacancy rules.
4. Landscaping and site-engineering. Develop separate measurable requirements for car wash
queue/vacuum screening, parking frontage buffers, utility screening where necessary, and planting. Do
not import KK’s proposed §3.04 as if already adopted.
5. Townhome zoning dimensions. Place the agreed six-unit limit, 150-foot length, 20/22-foot widths, 10-foot
end setbacks, and 20-foot end-to-end separation in the appropriate existing zoning dimensional
provisions or cross-reference them lawfully. Do not introduce an unagreed rear setback.
6. Measurable design administration. Define normal ground-level visibility, what constitutes effective
concealment, and documentation needed to apply 70/30 materials and townhome facade-variation
schedules consistently without subjective or arbitrary decisions.
7. Existing building and casualty conflicts. Coordinate the five-year 50-percent exterior wall-area triggers
with existing nonconforming-structure, building-permit, property-maintenance, and floodplain rules.
These thresholds are architectural area tests, not property valuation or floodplain substantial-
improvement tests.
8. Historic-preservation legal review. Reconcile 50-percent county improvement appraisal hardship,
mandatory approval absent neglect, evidence standards, relocation beyond Town limits, and archival
documentation with existing historic law and safety authority. Resolve any inconsistency in the Town’s
adopted property-maintenance code references.
9. Glazing and sign coordination. Implement the no-blacked-out-storefront standard without regulating
commercial messages or content. Confirm compatibility of architectural lighting, murals, awning logos,
and signs with the separate sign ordinance and applicable constitutional protections.
10. Source illustrations. Original KK drawings are preserved for reference only. Remove superseded
mandatory pitch, divided-light, facade offset, townhome-corner, and material-direction diagrams from
any eventual enacted ordinance, or replace them with accurate illustrative figures.
11. BAR notice, reconsideration, and permit coordination. Confirm applicable statutory and existing
local BAR hearing-notice requirements and reconcile existing §155.495(J) newspaper publication before
relying on general state-law notice language alone. Review the second-regular-meeting reconsideration
timing, one-reconsideration and 360-day restrictions, explicit judicial-appeal savings, 12-month
modification-hearing limit, and Building Official / Planning Official final-CO sequence.
12. Adoption pathway. Town Attorney, Town Architect, Planning Commission, BAR, and Council to review
statutory authority, hearing notice, appeal rights, dimensional-standard placement, enforceability,
historic protections, professional-review charges, and adoption procedure before formal introduction.
13. Written notices and applicant authorization. KK §7.01.04 requires an applicant with a property
interest or purchase contract; §7.01.09 requires written notice to the property owner and applicant. Confirm
appropriate owner/agent authorization and whether delivery to the owner as well as applicant is required
for BAR applications. The 30-day documentation target must not unintentionally change statutory appeal
triggers.
14. Conditional approvals and record. KK §7.01.08 calls for written conditions and applicant agreement,
while §7.01.09 allows revised plans to memorialize conditions. Confirm what consent, signed plans, and
Page 42 of 64
TOWN OF BLYTHEWOOD | BAR STANDARDS & PROCEDURES | WORKING DRAFT 04
Architectural and BAR procedure draft only | Not for adoption | November 11, 2026 | Page 25
recordkeeping are legally needed for enforceable BAR conditions without creating a second discretionary
approval.
15. KK general procedures are not automatically adopted. KK Chapter 7 contains 15/10-business-day
completeness reviews, 45-day cure periods, a 12-month successive-application restriction, 90-day withdrawal
hold, published/property hearing notices, and a general approval/appeal framework. These provisions
belong to KK’s unadopted comprehensive LDO; they should not be imported piecemeal into this targeted BAR
amendment. Reconcile only provisions actually applicable under the Town’s adopted Code or controlling
law.
16. COAs without building permits. Verify the 24-month commencement rule for approved work requiring
no building permit, including evidence of commencement and the appropriate enforcement remedy if work
deviates from approved plans. Like-for-like maintenance and same-color repainting remain exempt from
review.
REVIEW PRIORITIES | Counsel should focus first on statutory and adopted-code notice, appeals and deemed
approval, the five-member amendment, post-denial findings, repeated applications, professional-review cost
recovery, conditional approval documentation, and final-CO coordination. Settled architectural policy is not being
reopened.
SOURCE-TO-CODE CROSSWALK | FOR REVIEW
KK §2.03.01(E) Architectural Review Standards proposed §155.499→
KK §2.03.01(F) Overall Site Design proposed §155.500→
KK §2.03.01(G) Landscaping proposed §155.501→
KK §2.03.01(H) Building Orientation and Forms proposed §155.502→
Existing §155.503 Signage reserved and unchanged→
KK §2.03.01(I) Building Design Standards proposed §155.504→
KK §2.03.01(J) proposed SC/AU design standards material transitions and other architectural provisions integrated into→
§155.502; KK zoning districts NOT adopted
KK §3.02.01 overlapping site design inconsistent 90% masonry and window/landscape provisions excluded pending →
separate code reconciliation
Current historic preservation §§155.535–155.544 Part II coordinating policy (not a replacement chapter)→
KK §§2.03.01(D), 6.02.04, and Chapter 7 BAR-related procedures proposed Part III §§155.506–155.513; updated review →
tiers, Town Architect, hearing process, decisions, appeals, COA validity, and enforcement. KK’s general LDO procedure is
a comparison source, not automatically operative Town law.
KK architectural provisions concerning additions/alterations proposed §155.505, with five-year 50% exterior wall-area→
rules
PART VI | KENDIG KEAST RECONCILIATION
Source comparison completed against Kendig Keast’s May 22, 2025 proposed LDO §§2.03.01 and 6.02.04 and
Chapter 7’s common review procedures. Categories describe this working draft only. The KK LDO was a
proposal, not a substitute for the Town’s adopted Code. “Legal check” means Town Attorney review is
required, not that a settled policy choice is reopened.
INTENTIONALLY REVISED | Geographic coverage (KK §2.03.01) Use current Town zoning districts, TC,
the four named enhanced corridors, and other commercially zoned/used properties; do not import KK’s
Page 43 of 64
TOWN OF BLYTHEWOOD | BAR STANDARDS & PROCEDURES | WORKING DRAFT 04
Architectural and BAR procedure draft only | Not for adoption | November 11, 2026 | Page 26
SC/AU/MU/HT/OP/BC district names. Preserve the detached residential-use exemption and separate historic
review.
INTENTIONALLY REVISED | Three review tiers (KK §2.03.01(D)) Remove KK’s $50,000 staff threshold.
Exempt ordinary maintenance; authorize objective staff approval of eligible minor work with discretionary
referral; require BAR review for major work and architectural alternatives.
INTENTIONALLY REVISED | Submission and scheduling (KK §2.03.01(D); Ch. 7) Replace KK’s 10-
working-day BAR filing rule with a one-calendar-month mandatory deadline, with staff discretion for earlier
consideration. Preserve nonbinding 60-day administrative target and right to formal consideration after
required review.
RETAINED / REVISED | Application materials (KK §2.03.01(D); §7.01.04) Scaled elevations, materials,
colors, site context and photographs are addressed in §155.507(A). The Town may require information
reasonably related to the proposed work. Owner/agent authorization and notice to owner remain
counsel/form checks.
INTENTIONALLY REVISED | Site design and vehicle facilities (KK §2.03.01(F)) Allow context-appropriate
parking and street orientation; preserve safe circulation and required site approvals; prohibit conventional
drive-through lanes/queues between building and street, with a car wash exception.
GOVERNED ELSEWHERE | Landscaping and engineering (KK §2.03.01(G); Ch. 3) Retain architectural
screening principles but do not import unadopted KK berms, island widths, landscaping tables, or site
engineering as BAR design mandates. Existing Town zoning/site standards control.
INTENTIONALLY REVISED | Materials and building forms (KK §2.03.01(H)–(J)) Retain 70/30
primary/accent facade concept, genuine masonry, fiber cement, finished four-sided architecture, and
coherent articulation. Eliminate rigid wall offsets, roof pitches, divided lights, window transmission ratios,
material direction, and incompatible SC/AU restrictions.
INTENTIONALLY REVISED | Townhomes and multifamily (KK §2.03.01(I)) Retain agreed six-unit
maximum, frontage/width/separation rules, facade variation and usable private outdoor space; reject KK’s
four-corner, 2,000-square-foot coverage, rigid stoop/porch and front-door orientation rules. Coordinate
dimensional limits with zoning provisions.
RETAINED / REVISED | Architect and work sessions (KK §6.02.04) Retain independent nonvoting
technical review and optional public work sessions. Add Town-directed prepaid professional-review costs,
maximum two informal sessions, and a nonbinding architect recommendation.
RETAINED / REVISED | Board organization (KK §6.02.04) Five Town-resident members and three-person
quorum, not KK’s seven. Use recently adopted Town membership, appointment, officer and vacancy rules.
Confirm exact adopted amendment before codification.
LEGAL CHECK | Notice and participation (KK §6.02.04; §7.01.07–.08) General state-law notice and open-
meeting requirements; no automatic public-comment right at an ordinary BAR public meeting. Preserve
legally required hearing/party rights. Reconcile any current Town newspaper-notice provision.
INTENTIONALLY REVISED | Voting and written decisions (KK §6.02.04; §7.01.08–.09) Approval motions
only; unsuccessful approval motion is denial with reasons recorded at meeting. Written record to applicant
within 30 calendar days; minutes follow. Counsel to confirm legally adequate findings, conditional consent
and notice/effective-date rules.
INTENTIONALLY REVISED | Withdrawal, repeat applications, appeals (KK §7.01.04, .10–.11) Prehearing
withdrawal allowed; one BAR continuance; one reconsideration no earlier than second subsequent regular
Page 44 of 64
TOWN OF BLYTHEWOOD | BAR STANDARDS & PROCEDURES | WORKING DRAFT 04
Architectural and BAR procedure draft only | Not for adoption | November 11, 2026 | Page 27
meeting; 360-day similar-application bar after unsuccessful reconsideration. Court appeals and court-
ordered remands preserved. No deemed approval by lapse of time except if state law requires.
INTENTIONALLY REVISED | COA duration and modifications (KK §2.03.01(D); §7.01.09–.11) 24 months
to obtain building permit, then COA follows valid permit; nonpermit work has 24 months to commence. COA
follows project, not owner. Minor changes require Planning Official and Town Architect concurrence; one
formal modification hearing per rolling 12 months.
ADDED | Enforcement, CO coordination and emergencies (Town policy) Maintain controlling plans;
send approved plans to inspectors; enforce unauthorized deviations; Planning Official exterior sign-off
before final CO, subject to Building Official authority; emergency stabilization exempt from prior BAR
review.
LEGAL CHECK | Historic properties and codification (KK §6.02.05; §7.03.03) Part II records agreed
historic demolition hardship and relocation policy but does not itself replace existing historic-preservation
law. Counsel must reconcile with adopted historic, nonconforming, sign, zoning and building provisions;
final section numbers remain provisional.
APPENDIX | KENDIG KEAST SOURCE FIGURES
The following illustrations are retained from the May 2025 Kendig Keast source for traceability and
comparison, NOT as adopted or proposed design requirements. Some illustrate rules deliberately removed in
this draft. If this working text proceeds to an ordinance, only revised and legally accurate figures should be
included.
Figure 1 | SUPERSEDED
Five-foot recesses and projections are no longer mandatory; articulation may be achieved through alternative features.
Figure 2.03.01-1, Recesses and Projections
FIGURE NOTES:
A = Minimum 5 feet | B = Minimum 20 feet | C = Minimum 20 feet | D = Total Facade Length Greater than 100 feet
20% of D < B + C < 40% of D
Source illustration retained for discussion; the Part I text controls this working draft.
Page 45 of 64
TOWN OF BLYTHEWOOD | BAR STANDARDS & PROCEDURES | WORKING DRAFT 04
Architectural and BAR procedure draft only | Not for adoption | November 11, 2026 | Page 28
Figure 2 | ILLUSTRATIVE
Two-part facade concept remains a useful optional design approach.
Figure 2.03.01-2, Two-Part Commercial Building
FIGURE NOTES:
A = Base Zone | B = Shaft Zone
Source illustration retained for discussion; the Part I text controls this working draft.
Page 46 of 64
TOWN OF BLYTHEWOOD | BAR STANDARDS & PROCEDURES | WORKING DRAFT 04
Architectural and BAR procedure draft only | Not for adoption | November 11, 2026 | Page 29
Figure 3 | ILLUSTRATIVE
Three-part facade concept remains a useful optional design approach.
Figure 2.03.01-3, Three-Part Commercial Building
FIGURE NOTES:
A = Base Zone | B = Shaft Zone | C = Cap Zone
Source illustration retained for discussion; the Part I text controls this working draft.
Page 47 of 64
TOWN OF BLYTHEWOOD | BAR STANDARDS & PROCEDURES | WORKING DRAFT 04
Architectural and BAR procedure draft only | Not for adoption | November 11, 2026 | Page 30
Figure 4 | SUPERSEDED
Fixed 8:12–12:12 commercial roof pitch is removed.
Figure 2.03.01-4, Commercial Building Type Roof Slope and Eaves
FIGURE NOTES:
A = 12 inches | B = 8 to 12 inches | C = 12 to 36 inches
Roof materials should be limited to asphalt, fiberglass, or cedar shingles, concrete or clay tile, slate, or standing seam
metal.
Source illustration retained for discussion; the Part I text controls this working draft.
Page 48 of 64
TOWN OF BLYTHEWOOD | BAR STANDARDS & PROCEDURES | WORKING DRAFT 04
Architectural and BAR procedure draft only | Not for adoption | November 11, 2026 | Page 31
Figure 5 | SUPERSEDED
Undivided contemporary window panes are permitted; divided lights are not mandatory.
Figure 2.03.01-5, Non-Divided and Divided Light Windows
FIGURE NOTES:
A = Non-Divided Window (Prohibited) | B = Divided Light Window (Permitted)
Source illustration retained for discussion; the Part I text controls this working draft.
Page 49 of 64
TOWN OF BLYTHEWOOD | BAR STANDARDS & PROCEDURES | WORKING DRAFT 04
Architectural and BAR procedure draft only | Not for adoption | November 11, 2026 | Page 32
Figure 6 | ILLUSTRATIVE / NOT MANDATORY
Fuel canopy behind/side of store is preferred at prominent corners, with BAR-approved alternatives.
Figure 2.03.01-6, Convenience Store with Gasoline Sales
FIGURE NOTES:
A = Street Frontage | B = Convenience Store | C = Fuel Pumps
Source illustration retained for discussion; the Part I text controls this working draft.
Page 50 of 64
TOWN OF BLYTHEWOOD | BAR STANDARDS & PROCEDURES | WORKING DRAFT 04
Architectural and BAR procedure draft only | Not for adoption | November 11, 2026 | Page 33
Figure 7 | ILLUSTRATIVE
Two-part multifamily facade remains a possible design approach.
Figure 2.03.01-7, Two-Part Multi-Family Building
FIGURE NOTES:
A = Base Zone | B = Shaft Zone
Source illustration retained for discussion; the Part I text controls this working draft.
Page 51 of 64
TOWN OF BLYTHEWOOD | BAR STANDARDS & PROCEDURES | WORKING DRAFT 04
Architectural and BAR procedure draft only | Not for adoption | November 11, 2026 | Page 34
Figure 8 | ILLUSTRATIVE
Three-part multifamily facade remains a possible design approach.
Figure 2.03.01-8, Three-Part Multi-Family Building
FIGURE NOTES:
A = Base Zone | B = Shaft Zone | C = Cap Zone
Source illustration retained for discussion; the Part I text controls this working draft.
Page 52 of 64
TOWN OF BLYTHEWOOD | BAR STANDARDS & PROCEDURES | WORKING DRAFT 04
Architectural and BAR procedure draft only | Not for adoption | November 11, 2026 | Page 35
Figure 9 | SUPERSEDED
Fixed 5:12–12:12 multifamily roof pitch is removed.
Figure 2.03.01-9, Multi-Family Building Type Roof Slope and Eaves
FIGURE NOTES:
A = 12 inches | B = 8 to 12 inches | C = 12 to 36 inches
Roof materials should be limited to asphalt, fiberglass, or cedar shingles, concrete or clay tile, slate, or standing seam
metal.
Source illustration retained for discussion; the Part I text controls this working draft.
Page 53 of 64
TOWN OF BLYTHEWOOD | BAR STANDARDS & PROCEDURES | WORKING DRAFT 04
Architectural and BAR procedure draft only | Not for adoption | November 11, 2026 | Page 36
Figure 10 | SUPERSEDED
Four-corner restriction on townhome facades is removed.
Figure 2.03.01-10, Single-Family Attached Corners
FIGURE NOTES:
A = Single-Family Attached Residential Building | B = Public right-of-way
Source illustration retained for discussion; the Part I text controls this working draft.
Figure 11 | ILLUSTRATIVE
Heavier materials below lighter materials can be a successful design choice, but no mandated horizontal/vertical material
direction or hierarchy is retained.
Figure 2.03.01-11, Lighter and Heavier Materials
FIGURE NOTES:
A = Lighter Material (wood, true stucco) | B = Heavier Material (brick, stone, etc.)
Source illustration retained for discussion; the Part I text controls this working draft.
Page 54 of 64
TOWN OF BLYTHEWOOD | BAR STANDARDS & PROCEDURES | WORKING DRAFT 04
Architectural and BAR procedure draft only | Not for adoption | November 11, 2026 | Page 37
Figure 12 | SUPERSEDED / CONFLICTING SOURCE
Source contains inconsistent horizontal-versus-vertical material change instructions; no such blanket mandate is carried
forward.
Figure 2.03.01-12, Horizontal Materials Change
Source illustration retained for discussion; the Part I text controls this working draft.
Page 55 of 64
# Policy area KK proposal Draft No. 4 Draft section Primary reviewer
1 Administrative review KK: staff review limited by $50,000 threshold. Draft 4: objective minor-work staff approval, major projects still
BAR.
§155.506 Both
2 Architectural materials KK: 70/30 general rule, plus some stricter building-type
limits.
Draft 4: uniform 70/30 opaque prominent-elevation rule; genuine
thin brick allowed.
§§155.499, .502 Ralph
3 Design flexibility KK: prescribed offsets, roof pitches, glazing percentages
and traditional compositions.
Draft 4: performance-oriented architecture with measurable
material and visibility rules.
§155.502 Ralph
4 Geographic scope KK: overlay tied to proposed zoning districts and broader
storefront-street list.
Draft 4: current districts plus four enhanced corridors; Main
Street pedestrian emphasis.
§§155.499–.500 Ralph
5 Drive-through design KK: service windows side/rear, coordinated canopies. Draft 4: no conventional front lanes/queues; separate car wash
exception.
§§155.500, .504 Ralph
6 Townhome design KK: 2,000-sf coverage, four-corner facade and limited
variation.
Draft 4: six-unit cap, widths, separation and stronger facade
differentiation.
§155.504(G) Both
7 Professional review KK: optional nonvoting adviser funded through Town. Draft 4: Town Architect advisory, applicant prepayment and
transparent actual-cost review.
§155.508 Both
8 BAR procedures KK: seven-member Board and general LDO review/hearing
rules.
Draft 4: five members, three-person quorum, defined motions
and written records.
§155.509 Pete
9 Appeals / lapse of time KK: 45-day deemed approval for some administrative
appeals.
Draft 4: no lapse-of-time approval unless state law requires it. §155.511 Pete
THE MOST MATERIAL POLICY DIFFERENCES
BAR ORDINANCE | EXECUTIVE COMPARISON
A decision-oriented guide for Town Architect Ralph and Town Attorney Pete. Source: proposed KK LDO (May 22, 2025) vs. BAR Working Draft No. 4 (Nov. 11, 2026).
Comparison topics 82Detailed side-by-side in the Difference Matrix tab
Page 56 of 64
10 Historic protections KK: historic classification and designation system. Draft 4: keeps existing historic law; separately proposes
demolition hardship/relocation policy.
Part II Pete
WHAT THIS MATRIX IS (AND ISN'T)
This is a comparison of two proposed texts. It does not imply Ralph or Pete endorsed every KK provision, that KK was adopted, or that Draft 4 is adoption-ready. The matrix distinguishes deliberate policy revisions from
items left to adopted zoning, historic, sign, and state law. Only the legal reconciliation items require counsel before introduction.
Page 57 of 64
# Area Subject Kendig Keast (May 2025) Working Draft No. 4 Change / practical effect Classification KK section reference Draft 4 reference Review lead Priority Reviewer comments / requested edits
1 01 · Scope Applicable zoning districts Architectural overlay includes proposed SC, AU, TC, MU, HT,
OP and BC districts plus commercial PD uses.
Uses currently adopted Town zoning and TC, four named
corridors, other commercially zoned/used property and covered
PD uses.
Does not depend on adopting KK’s new district map or
names.
Revised KK §2.03.01(A)–(B) Draft 4 §155.499(B),(D) Both High Confirm actual zoning cross-references and
boundaries.
2 01 · Scope Enhanced corridors KK requires retail storefront treatment on 11 listed streets;
SC/AU districts have additional rules.
Four enhanced corridors: Main/Wilson, Blythewood,
McNulty/Extension, Langford; Main Street receives strongest
pedestrian-frontage treatment.
Concentrates enhanced review on four corridors without
extending a downtown storefront model to all commercial
roads.
Revised KK §2.03.01(I), Commercial Building Type;
SC/AU rules
Draft 4 §§155.499(D), 155.500(B)–(C),
155.502(E)(3)–(4)
Ralph High
3 01 · Scope Residential coverage and
detached homes
KK covers commercial uses in overlay and noncommercial
buildings within TC; its building types include multifamily and
attached residential.
Expressly covers multifamily and townhomes in stated
locations; exempts existing detached single-family homes used
as residences from ordinary BAR review.
Makes ordinary residential exemption explicit; designated
historic rules remain separate.
Clarified KK §2.03.01(B)–(D),(I) Draft 4 §155.499(B) Both High
4 01 · Scope Architectural vs zoning authority KK includes architecture, parking/landscaping, building heights
and zoning district-specific restrictions in its comprehensive
LDO.
BAR approval does not vary zoning, height, setbacks, parking,
access, drainage, building codes, landscaping or permitted
uses.
Separates design review from the Town’s other regulatory
approvals.
Revised KK §2.03.01(F)–(J) Draft 4 §155.499(F) Pete High
5 01 · Scope Signs and advertising KK architectural provisions address awnings; its broader LDO
contains separate sign procedures.
Existing sign ordinance controls sign permits, content and
advertising; BAR may address physical architectural treatment
only.
Avoids creating new sign-content authority through the
architectural ordinance.
Clarified KK §2.03.01(H)–(I); §7.02.07 Draft 4 §§155.499(F), 155.502(H)–(I),
155.503
Pete Medium
6 02 · Review process Administrative approval
threshold
Planning Official may decide COAs at or below $50,000 when
there is no major visual impact; may refer to BAR.
No dollar threshold: exempt maintenance, objective staff review
for minor changes, BAR for major
buildings/renovations/alternatives.
Classifies review by architectural impact rather than
construction cost.
Revised KK §2.03.01(D), COA Required Draft 4 §155.506(A)–(E) Both High
7 02 · Review process Routine maintenance KK requires COA for regulated exterior alterations; does not set
out the same express maintenance exemption in §2.03.01(D).
Like-for-like windows, doors, roofing, approved-color repainting
and routine repairs are exempt from architectural approval.
Eliminates unnecessary hearings for changes with no
material design effect.
Added KK §2.03.01(D) Draft 4 §155.506(B) Both High
8 02 · Review process Staff referral to BAR Planning Official may forward otherwise eligible minor projects
to BAR.
Planning Official retains discretion to refer administratively
eligible work to BAR without denying first.
Preserves citizen oversight when a minor application raises
material design questions.
Retained KK §2.03.01(D), COA Required Draft 4 §155.506(C)–(D) Both Medium
9 02 · Review process BAR submission deadline Application filed 10 working days before regularly scheduled
BAR meeting.
File at least one calendar month before requested meeting;
Planning Official may accept later if review can be completed.
Creates review time without requiring denial of a workable
late submission.
Revised KK §2.03.01(D), Application Required Draft 4 §155.507(B) Pete High
10 02 · Review process Application materials Scaled elevations, samples of materials/colors, circulation
plans, photos of building and adjacent properties, other
necessary data.
Scaled elevations, site relationships, materials/colors and
context photos to the extent relevant to the work.
Keeps core documentation; avoids demanding unrelated
materials for small projects.
Refined KK §2.03.01(D), Data to be Submitted Draft 4 §155.507(A) Both Medium
11 02 · Review process Completeness review KK general Chapter 7 uses 15 business days for deadline-
driven and 10 for other applications; 45 days to cure
incomplete submissions.
Planning Official determines completeness and identifies
deficiencies; no KK-specific 10/15-day or 45-day schedule
imported.
Avoids automatically adopting procedures from a proposed
comprehensive LDO.
Revised KK §7.01.04 Draft 4 §155.507(A)–(C) Pete Medium Confirm existing adopted completeness
requirements.
12 02 · Review process Review and hearing timing 10-working-day BAR filing requirement plus general Chapter 7
timelines; no comparable 60-day BAR scheduling target in
§2.03.01.
Nonbinding ~60-day scheduling target after application
deadline; no guaranteed meeting or deemed approval.
Allows staff, Town Architect and applicant revisions before
formal hearing.
Revised KK §2.03.01(D); §7.01 Draft 4 §155.507(B)–(D) Pete High
13 02 · Review process Right to a formal BAR decision KK identifies BAR as decision-maker but does not expressly
grant this same right after required technical review.
After complete filing and required professional review, applicant
may demand formal consideration despite unfavorable
staff/architect recommendation.
Prevents indefinite staff-level negotiation from blocking a
formal decision.
Added KK §2.03.01(D); §6.02.04 Draft 4 §155.507(D) Pete High
14 02 · Review process Town Architect role BAR may appoint a nonvoting technical adviser; outside advice
contingent on Town funding.
Town-retained architect advises staff/BAR; recommendation
nonbinding; contrary BAR decision supported by ordinance
findings.
Uses independent expertise without replacing the volunteer
BAR.
Revised KK §6.02.04, Technical Advisor / Outside
Advice
Draft 4 §155.508(A),(C)–(D) Both High
15 02 · Review process Professional review costs KK §6.02.04 describes compensation from Town budget; no
applicant prepayment procedure stated there.
Applicant prepays Town based on quoted scope; Town pays
architect, refunds unused funds and seeks justified
supplements.
Makes professional review cost recovery transparent and
project-specific.
Added KK §6.02.04, Technical Advisor / Outside
Advice
Draft 4 §155.508(B)–(D) Pete High Verify fee-schedule authority and lawful cost recovery.
16 02 · Review process Informal work sessions BAR may hold preapplication/informal work sessions; no
binding decisions.
Optional noticed work sessions, maximum two for
same/substantially similar proposal, no binding votes.
Preserves collaborative design input with a defined limit. Refined KK §2.03.01(D), Preapplication; §6.02.04,
Work Sessions
Draft 4 §155.508(E) Both Medium
17 02 · Review process Architect recommendation and
hearing
KK technical adviser is nonvoting; no express requirement in
cited section to provide recommendation to applicant before
meeting.
Architect’s written recommendation given to applicant before
hearing; architect normally attends unless Planning Official
excuses.
Improves transparency and access to professional advice. Added KK §6.02.04, Technical Advisor Draft 4 §155.508(C)–(D) Both Medium
18 03 · Site & services Street orientation Buildings generally face street; parking to side/rear where
feasible.
Main Street favors street frontage and side/rear parking; other
enhanced corridors permit lawful auto-oriented front parking.
Adjusts expectations to corridor context. Revised KK §2.03.01(F), Front Setback / Parking Draft 4 §155.500(A)–(D) Ralph High
19 03 · Site & services Conventional drive-through Drive-through windows at side/rear; canopy architecture
compatible with principal building.
Windows, lanes and queues at side/rear; none between
building and public street; BAR cannot waive.
Clarifies and strengthens location rule for
restaurants/banks/pharmacies.
Strengthened KK §2.03.01(H), Covered Drive-Through Draft 4 §§155.500(F), 155.504(C),
155.510(B)
Ralph High
20 03 · Site & services Car wash exception KK groups accessory automobile wash/detailing with
convenience-store uses and discusses accessory siting.
Car wash may have street-facing tunnel openings and front
queues where lawful; queues must stay onsite.
Avoids applying conventional drive-through ban to the
functional layout of a car wash.
Added KK §2.03.01(I), Convenience Store /
Accessory Structures
Draft 4 §§155.500(G), 155.504(D) Ralph Medium
21 03 · Site & services Gas station canopy Canopies and accessory wash/detailing coordinate with
principal building and generally sit farther from street.
Coordinated canopy; all exposed fuel-canopy columns clad full
height in approved primary material; fascia need not be brick.
Defines visible canopy quality while allowing practical fascia
design.
Refined KK §2.03.01(H), Canopies; §2.03.01(I),
Gasoline Sales
Draft 4 §155.504(B) Ralph High
KENDIG KEAST → WORKING DRAFT NO. 4 | DIFFERENCE MATRIX
May 22, 2025 proposed LDO compared with Blythewood BAR Working Draft No. 4 (Nov. 11, 2026). Policy comparison, not a legal redline or an adopted ordinance.
Filter by reviewer, priority, category or change type. “Reviewer comments” is intentionally blank for Ralph and Pete. “No direct counterpart” means no counterpart identified in the cited KK provisions, not a claim about every other law.
Page 58 of 64
22 03 · Site & services Corner gas station layout KK identifies selected intersections requiring storefront
treatment and generally places accessory structures behind
principal building.
Corner store preferred at prominent enhanced-corridor
intersections, with equivalent attractive alternatives possible.
Maintains a strong preference without an absolute site-plan
formula.
Revised KK §2.03.01(I), Gasoline Sales Draft 4 §155.504(B)(4) Ralph Medium
23 03 · Site & services Traffic and parking standards KK overlay includes SCDOT/site-plan access and circulation
criteria; parking screening and landscape requirements.
Architectural review acknowledges but does not replace
engineering, SCDOT, parking and site-plan approvals.
Avoids duplicate or conflicting design and engineering
authority.
Governed elsewhere KK §2.03.01(F) Draft 4 §§155.499(F), 155.500(E) Pete Medium
24 03 · Site & services Landscape islands and berms KK specifies two-foot parking berm/screen and eight-foot
landscaped islands; refers to landscaping chapter.
Landscaping numbers and buffers governed by existing
site/landscaping regulations; BAR focuses on architectural
compatibility.
Avoids importing KK’s proposed landscape dimensions
through a BAR rewrite.
Governed elsewhere KK §2.03.01(F)–(G) Draft 4 §155.501(A)–(B) Both Medium
25 03 · Site & services Decorative fences KK lists permitted fence materials and prohibits visible chain-
link; includes required brick/stone columns.
Decorative frontage fencing optional; durable compatible
materials; chain-link/privacy fence not acceptable as decorative
commercial frontage.
Preserves frontage quality without requiring a fence. Revised KK §2.03.01(I), Fences, Gates, Walls Draft 4 §155.501(C) Ralph Medium
26 03 · Site & services Fence columns and dimensions KK requires masonry columns no more than 30 feet apart and
imposes 32-inch sidewalk-zone fence height.
Masonry columns encouraged, not required; no fixed spacing
imposed by architectural article.
Avoids mandatory ornamentation and dimensional
duplication.
Revised KK §2.03.01(I), Fences, Gates, Walls Draft 4 §155.501(D) Ralph Medium
27 03 · Site & services Ground mechanical screening KK requires screening of service equipment and utility
installations from pedestrian views.
Screen ground-mounted equipment visible off-site; materials
may be walls, fencing, landscaping or topography.
Retains screening while allowing methods other than
masonry.
Retained / refined KK §2.03.01(G),(I), Outdoor Service
Equipment
Draft 4 §155.501(E) Ralph Medium
28 03 · Site & services Rooftop equipment and solar KK screens rooftop mechanical equipment from
street/pedestrian view; no express solar exception in cited
architecture text.
Rooftop HVAC screened from normal street-level views; rooftop
solar exempt from architectural screening, subject to other law.
Targets real public visibility and accommodates solar. Refined / added KK §2.03.01(H),(I), Rooflines / Service
Equipment
Draft 4 §155.501(F)–(G) Ralph Medium
29 03 · Site & services Dumpsters KK gated/screened dumpsters, attached enclosure identical
and detached complementary to principal building.
Enclosure walls use approved primary building material;
opaque functional gates may use complementary materials.
Consistent architectural walls with practical service gates. Refined KK §2.03.01(G), Trash Enclosures Draft 4 §155.501(H) Ralph Medium
30 03 · Site & services Accent and decorative lighting KK directs lighting downward and away from adjacent
properties; separate sign/building treatments.
Allows controlled colored uplighting; prohibits permanent
exposed LED outline strips; temporary holiday lighting allowed.
Separates acceptable architectural illumination from
conspicuous building outlines.
Revised KK §2.03.01(G), Lighting Draft 4 §155.501(I) Ralph Medium
31 04 · Architectural
design
70/30 primary/accent ruleKK general commercial materials list labels primary ≥70% and
accent ≤30%, but later civic/multifamily provisions impose
≤10% accents.
Uniform ≥70% primary/≤30% accent of opaque wall area on
each prominent elevation across covered building types.
Preserves a measurable quality standard and removes
inconsistent building-type percentages.
Retained / harmonized KK §2.03.01(H), Building Materials;
§2.03.01(I), Civic / Multifamily
Draft 4 §§155.499(C), 155.502(A),
155.504(E)–(F)
Ralph High
32 04 · Architectural design Primary materials and thin brickKK lists full brick, stone, cement boards etc.; later prohibits thin
brick veneer and split-faced brick on facades.
Allows genuine fired-clay thin brick, anchored veneer, split-
faced genuine brick, precast genuine brick, stone and fiber
cement as primary.
Allows durable modern cladding while distinguishing
genuine masonry from imitation.
Revised KK §2.03.01(H), Materials; §2.03.01(I),
Prohibited Materials
Draft 4 §155.502(A)(2)–(4) Ralph High
33 04 · Architectural design Stucco, EIFS and CMU KK general list treats hard-coat stucco as primary, synthetic
stucco as accent; later prohibits CMU on any facade.
Stucco/EIFS and decorative CMU limited to accent use;
ordinary finished CMU may be used on effectively concealed
service walls.
Emphasizes durable primary facades while permitting
reasonable screened service construction.
Revised KK §2.03.01(H)–(I), Materials Draft 4 §155.502(A),(B) Ralph High
34 04 · Architectural design Four-sided design KK requires architectural treatment of visible sides and rears;
facade restrictions vary by type/district.
All four sides durably finished; prominent elevations treated
fully, concealed service walls may be simpler.
Maintains four-sided quality without four identical
storefronts.
Clarified KK §2.03.01(G), Sides and Rear; §2.03.01(I) Draft 4 §155.502(B) Ralph High
35 04 · Architectural design 50-foot articulation KK requires wall-plane offset of at least two feet per 50 feet of
length.
Meaningful architectural rhythm generally about every 50 feet;
alternatives include pilasters, openings, canopies and
materials.
Replaces mechanical recess formula with architectural
performance standard.
Revised KK §2.03.01(H), General Features Draft 4 §155.502(C)(1)–(2) Ralph High
36 04 · Architectural design Long facade offsets KK requires major articulation for >200-foot commercial
facades and detailed five-foot recess/projection formulas on
certain facades.
Multiple articulation methods for >100 feet; more substantial
changes generally at ≤100-foot intervals on >200-foot facades;
no rigid five-foot formula.
Retains relief on large buildings with design flexibility. Revised KK §2.03.01(I), Commercial Building Type Draft 4 §155.502(C)(3) Ralph High
37 04 · Architectural design Roof pitches and forms KK commercial roofs generally 8:12–12:12, multifamily
5:12–12:12; flat roofs with parapets; false mansards barred.
Pitched, flat and low-slope roofs allowed with integrated design;
false applied mansards prohibited.
Removes prescribed pitch ranges without sacrificing
roofline quality.
Revised KK §2.03.01(H)–(I), Roofs Draft 4 §155.502(D) Ralph High
38 04 · Architectural design Gutters and flashing KK names copper/aluminum/galvanized gutters, matching
downspouts, specific flashing.
Durable, compatible roof drainage and flashing; no mandated
metal or exact matching finish.
Avoids unnecessary product specifications. Revised KK §2.03.01(I), Gutters / Downspouts /
Flashing
Draft 4 §155.502(D)(2) Ralph Low
39 04 · Architectural design Window configuration KK requires divided/fixed glazing, vertically oriented windows,
grid patterns, sills and other traditional features.
Traditional or contemporary windows; no universal divided-light,
grid, vertical-aspect or masonry-sill mandates.
Allows coherent contemporary architecture. Revised KK §2.03.01(H)–(I), Windows Draft 4 §155.502(E)(1) Ralph High
40 04 · Architectural design Glazing transmission and
reflectance
KK includes 88% clear glazing language, later 60%
transmission and 0.20 maximum reflectance.
No universal numeric transmission/reflectance values; low-
E/tint allowed; highly mirrored or blocked-looking prominent
windows barred.
Removes conflicting numeric glazing rules while protecting
street appearance.
Revised KK §2.03.01(H), Windows; §2.03.01(I),
Transmittance / Reflectance
Draft 4 §155.502(E)(2) Ralph High
41 04 · Architectural design Main Street transparency KK calls for storefront treatments on retail facades along a
broader street list.
Authentic transparent retail/restaurant glazing required on
Main/Wilson; no universal storefront on other three corridors.
Prioritizes pedestrian transparency where it matters most. Revised KK §2.03.01(I), Commercial Building Type Draft 4 §155.502(E)(3)–(5) Ralph High
42 04 · Architectural design Multistory base/shaft/cap KK mandates two- or three-part composition and floor divisions
on certain multi-story commercial and multifamily buildings.
Encourages traditional composition but allows other coherent
contemporary arrangements.
Eliminates compulsory historicist form. Revised KK §2.03.01(I), Multi-story Facades Draft 4 §155.502(F)(1) Ralph Medium
43 04 · Architectural design Material transitions KK SC/AU rules prescribe horizontal combinations and vertical
changes; lighter-over-heavier.
Allows intentional horizontal or vertical transitions without
heavier-below-lighter formula.
Resolves conflicting orientation requirements. Revised KK §2.03.01(I)–(J), Material Expression / SC-
AU
Draft 4 §155.502(G)(1) Ralph High
44 04 · Architectural design Exterior color KK limits bold primary colors to accents and bans bright
fluorescent/dayglow colors.
Bold/corporate colors allowed if coherent; dayglow/fluorescent
and highly reflective finishes barred.
Preserves architectural judgment without banning a brand
palette.
Revised KK §2.03.01(H), Colors Draft 4 §155.502(F)(2) Ralph High
Page 59 of 64
45 04 · Architectural design Awnings and shutters KK restricts awning placement/form; requires shutter width
≈half window; bans internally lit awnings.
Durable traditional or modern canopies; plausible shutter
proportions/hardware; internally glowing awnings still banned.
Retains credible detailing but drops fixed geometry. Revised KK §2.03.01(H)–(I), Awnings / Shutters Draft 4 §155.502(G)(3),(H) Ralph Medium
46 04 · Architectural design Murals No comparable general mural placement rule identified in KK
§2.03.01.
BAR may review placement/installation on covered property,
not mural message or murals townwide.
Clarifies limited architectural jurisdiction over murals. Added No direct counterpart in KK §2.03.01 Draft 4 §155.502(I)(1) Pete Medium
47 04 · Architectural design Existing unpainted masonryNo comparable general prohibition identified in KK §2.03.01 on
painting previously unpainted nonhistoric brick/stone.
Protects existing natural brick/stone from paint, limewash, stain
and murals; previously painted may repaint; new painted brick
allowed.
Protects existing natural masonry without banning
designed painted-brick construction.
Added No direct counterpart in KK §2.03.01 Draft 4 §155.502(I)(2) Both High
48 05 · Building types Civic building materials KK civic building type permits no more than 10% accent
materials per floor.
Civic buildings use same 70/30 prominent-elevation rule as
other covered types.
Avoids a separate 90% primary-material rule for civic
buildings.
Revised KK §2.03.01(I), Civic Building Type Draft 4 §155.504(E) Ralph Medium
49 05 · Building types Multifamily facade length KK caps multifamily principal facades at 200 feet and requires
two major articulation points over 100 feet.
No absolute 200-foot limit in architectural standards;
meaningful articulation still required.
Allows longer buildings when well designed. Revised KK §2.03.01(I), Multifamily Building Type Draft 4 §155.504(F)(1) Ralph Medium
50 05 · Building types Multifamily porches and stoops KK mandates 5×5 covered porches, 12-inch raised first floors
and bans front stoops for certain units.
Usable private outdoor space for units with direct exterior
access; stoops allowed; interior-corridor alternatives possible.
Focuses on usable amenities and accessibility, not
decorative porch dimensions.
Revised KK §2.03.01(I), Multifamily Stoops and
Porches
Draft 4 §155.504(F)(3)–(4) Ralph High
51 05 · Building types Townhome row size KK attached housing building type imposes facade/corner
rules; separate KK definition references a 250-foot townhouse
length.
Maximum six attached units per building and 150-foot frontage. Establishes smaller townhome building groups; requires
placement in correct zoning provisions.
Added / revised KK §2.03.01(I), Single-Family Attached; KK
Townhome definition
Draft 4 §155.504(G)(1)–(2) Both High Coordinate with adopted zoning dimensions.
52 05 · Building types Townhome widths and separation No matching 20-foot unit width, 22-foot average or 20-foot end-
to-end building gap identified in KK architectural provisions.
Minimum 20-foot unit width, 22-foot building average, 10-foot
exterior end setbacks and 20-foot landscaped end-to-end gap.
Adds specific neighborhood-scale separation and unit-width
requirements.
Added KK §2.03.01(I), Single-Family Attached Draft 4 §155.504(G)(3)–(5) Both High Coordinate with zoning, fire and building codes.
53 05 · Building types Townhome facade variety KK allows up to three adjacent units with same facade design. Adjacent units must differ; six distinct combinations per row; at
least 12 combinations for developments of 12+ units.
Strengthens anti-monotony requirements. Strengthened KK §2.03.01(I), Facade Differentiation Draft 4 §155.504(G)(6)–(8) Ralph High
54 05 · Building types Townhome coverage and corners KK limits per-unit land coverage to 2,000 square feet and front
facade to four corners.
Both architectural limits removed; existing zoning lot coverage
continues.
Avoids design-by-formula and keeps dimensional controls
in zoning.
Removed KK §2.03.01(I), Coverage / Principal Facades Draft 4 §155.504(G)(10) Both Medium
55 05 · Building types Townhome entrance orientation KK architectural text reviewed does not set a matching uniform
door-facing rule.
No front-door orientation mandate; corner and recessed entries
may be designed for context.
Avoids an unnecessary restriction on workable townhouse
layouts.
Clarified KK §2.03.01(I), Single-Family Attached Draft 4 §155.504(G); townhome diagram
note
Ralph Low
56 05 · Building types Townhome garages KK general garage facade materials should match principal
structure.
Front garages allowed if subordinate to residence; single doors
encouraged, two-car doors allowed.
Controls appearance rather than prescribing garage
configuration.
Refined KK §2.03.01(I), Garage Facade Materials Draft 4 §155.504(G)(9) Ralph Medium
57 06 · Existing & historic Existing-building retrofit triggerKK §2.03.01 applies architectural review to major
improvements/alterations; no matching five-year wall-area test
identified there.
50% of one elevation’s exterior wall area in rolling five years
triggers affected elevation; 50% of total wall area triggers all
elevations.
Defines predictable, area-based retrofit thresholds. Added KK §2.03.01(D), Major Improvement /
Alteration
Draft 4 §155.505(C)–(F) Both High Coordinate with existing nonconforming provisions.
58 06 · Existing & historic Casualty and repairs KK architectural review applies to improvements/alterations;
separate LDO rules may govern nonconformities.
Routine maintenance/repairs excluded from retrofit test; major
casualty reconstruction subject to same area thresholds.
Avoids automatic whole-building retrofit for minor work;
does not blanket-exempt reconstruction.
Clarified KK §2.03.01(D); other KK nonconformity
provisions
Draft 4 §155.505(F)–(I) Pete High Coordinate with floodplain, casualty and
nonconforming law.
59 06 · Existing & historic Nonhistoric demolition KK BAR overlay focuses on COAs for new
construction/alteration; separate historic designation rules exist.
No BAR demolition approval for buildings lacking lawful historic
designation; other demolition/safety permits still required.
Limits architectural demolition review to historic protection. Clarified KK §2.03.01(D); §7.03.03 Draft 4 Part II(A) Pete High
60 06 · Existing & historic Historic designation framework KK §7.03.03 proposes Class I/II designation criteria and
Council designation process; BAR serves as Historic
Preservation Board.
Draft 4 does not replace adopted designation process; Part II
only proposes historic demolition/relocation policy for
integration.
Prevents the architectural rewrite from silently replacing
historic preservation law.
Governed elsewhere KK §§6.02.04–6.02.05, 7.03.03 Draft 4 Part II introduction, (F) Pete High Confirm adopted historic law and how new provisions
integrate.
61 06 · Existing & historic Historic demolition hardship KK historic designation section addresses Class I/II protection
and negotiations; no identical assessor-improvement-value
hardship test in cited section.
For designated historic buildings, documented rehabilitation
cost >50% of County Assessor improvement value (land
excluded) establishes proposed hardship threshold.
Adds an objective economic-hardship metric; requires
separate legal integration.
Added KK §7.03.03, Historic Preservation District Draft 4 Part II(B)–(C) Pete High Review adopted §155.543 and demolition-by-neglect
rule.
62 06 · Existing & historic Demolition by neglect No matching specific no-prior-citation test identified in KK
§7.03.03 designation provisions.
BAR may reject hardship demolition if substantial deterioration
due to prolonged owner neglect, based on evidence; prior
citation not essential.
Prevents hardship from rewarding deliberate neglect while
requiring documented findings.
Added KK §7.03.03; adopted historic chapter
separately
Draft 4 Part II(C) Pete High
63 06 · Existing & historic Historic demolition documentation KK historic protection framework does not state the same
limited digital photo archival requirement in §7.03.03.
Requires accessible exterior/detail photographs for Town
archive; no routine costly measured-drawing survey.
Creates practical preservation record before authorized
demolition.
Added KK §7.03.03, Historic Preservation District Draft 4 Part II(D) Both Medium
64 06 · Existing & historic Relocation of historic building KK Class II provisions contemplate negotiated
relocation/purchase/incentives for preservation.
Permits credible relocation outside Town; no mandatory Town-
only destination or special bond solely under this policy.
Supports preservation through viable relocation rather than
location-based restriction.
Revised KK §7.03.03, Class II Historic Properties Draft 4 Part II(E) Pete Medium
65 07 · BAR governance Board membership KK: seven Town residents, numbered seats, fixed staggered
terms, January/July advertising, September appointments.
Draft 4: five Town-resident members, quorum three;
terms/appointments governed by recently adopted Town
provisions.
Uses Town’s reported current Board structure rather than
KK’s proposed seven-member calendar.
Revised KK §6.02.04, Composition / Appointments Draft 4 §155.509(A) Pete High Verify adopted five-member ordinance and residency
rule.
66 07 · BAR governance Quorum and voting KK: majority of seven for quorum; general Chapter 7 simple-
majority voting.
Three eligible members form quorum; chair votes; approval
requires majority of eligible members present.
Updates quorum to five-member structure; recusals do not
count.
Revised KK §6.02.04, Rules; §7.01.08, Votes Draft 4 §155.509(A),(E) Pete High
67 07 · BAR governance Public notice KK calls for newspaper/public posting of regular meetings;
Chapter 7 has additional hearing notice rules.
General state-law notice and open meetings; any still-
applicable adopted Town notice rule remains in force.
Avoids writing extra posting deadlines while preserving
mandatory notice.
Revised / legal check KK §6.02.04, Rules; §§7.01.07–.08 Draft 4 §155.509(C) Pete High Reconcile existing §155.495(J) newspaper notice.
Page 60 of 64
68 07 · BAR governance Public meeting vs hearing KK distinguishes public meetings and hearings; hearing rules
allow eligible speakers and evidentiary participation.
Public attendance alone does not grant general comment right
on ordinary BAR applications; legally required participation
protected.
Clarifies hearing rights without treating every application as
open-mic testimony.
Clarified KK §7.01.08 Draft 4 §155.509(C) Pete High
69 07 · BAR governance BAR motion and denial KK permits approval, conditional approval and disapproval, with
reasons recorded.
Only approval/conditional-approval motions; failed approval
vote is denial; dissenting reasons documented on record.
Changes decision mechanics; requires legal review of
adequate findings.
Revised / legal check KK §6.02.04, Rules; §7.01.08, Final Action Draft 4 §155.509(E)–(F) Pete High
70 07 · BAR governance Written decisions KK requires reasons in minutes and decision document;
Chapter 7 written approval/notice to owner and applicant.
BAR votes at meeting; staff sends written memorialization
within 30 calendar days; minutes later.
Separates vote from documentation while retaining reasons
and appeal information.
Refined / legal check KK §6.02.04, Rules; §7.01.09 Draft 4 §155.509(G) Pete High Confirm legal effective date, notice and appeal clock.
71 07 · BAR governance Approval conditions KK Chapter 7 requires conditions/reasons in writing and
applicant agreement.
Conditions must be specific, verifiable, tied to ordinance; no
delegation of a new discretionary decision.
Limits vague conditions and post-hearing re-review. Refined / legal check KK §7.01.08, Conditional Approval; §7.01.09 Draft 4 §155.510(C) Pete Medium Confirm consent/documentation requirements.
72 07 · BAR governance Architectural alternatives KK allows minor design deviations; no identical
equivalent/superior finding and nonwaivable-list framework in
cited text.
BAR may approve equivalent/superior alternatives with
findings; cannot waive 70/30, six-unit townhome cap or front
drive-through prohibition.
Provides flexibility for design, not an unlimited variance
power.
Revised KK §2.03.01(I), Building Design Standards Draft 4 §155.510(A)–(B) Both High
73 07 · BAR governance Withdrawal and continuances KK Chapter 7 allows continuing matters and has 90-day hold
after certain withdrawals; separate 12-month successive-
application rule.
Withdraw/reschedule before hearing; withdrawal after hearing
counts as heard; BAR one continuance; no quorum
reschedules without penalty.
Creates BAR-specific hearing controls rather than importing
all KK general LDO rules.
Revised KK §§7.01.04, 7.01.08, 7.01.11 Draft 4 §155.509(H) Pete Medium
74 07 · BAR governance Reconsideration / repeat
applications
KK generally bars substantially similar denied applications for
12 months, subject to new evidence/substantial change.
One reconsideration no earlier than second following regular
meeting; 360-day repeat bar after unsuccessful
reconsideration, with court rights preserved.
Permits a defined second chance, then limits repeated
identical applications.
Revised / legal check KK §7.01.04, Successive Applications Draft 4 §155.511(A)–(B),(E) Pete High Check trigger and wording for post-hearing
withdrawal.
75 07 · BAR governance Appeal structure KK: appeal staff decision to BAR in 15 days; final BAR decision
to Circuit Court under applicable statute.
Final staff architectural decision → BAR; final BAR decision →
Circuit Court; no Town Council appeal.
Retains basic appeal route while reserving deadlines for
controlling law.
Retained / refined KK §7.01.10 Draft 4 §155.511(C)–(E) Pete High
76 07 · BAR governance Automatic approval on missed
appeal deadline
KK §7.01.10 states administrative appeal deemed approved if
BAR fails to decide within 45 days absent agreed extension.
No COA/architectural application deemed approved by elapsed
time unless state law expressly requires it.
Rejects administrative default approval; legal reconciliation
needed for existing 45-day clause.
Revised / legal check KK §7.01.10, BAR Appeal Draft 4 §155.511(F) Pete High Confirm whether existing §155.497(C) may be
amended.
77 07 · BAR governance COA duration KK: COA valid 24 months; work must begin in that period;
Planning Commission approval may start clock.
For permitted work: building permit must issue within 24
months, then COA follows permit; nonpermit work must begin
within 24 months.
Avoids second expiration clock once a valid building permit
exists.
Revised KK §2.03.01(D), COA Duration Draft 4 §155.512(A)–(C) Pete High
78 07 · BAR governance Approval follows property KK Chapter 7 states development approvals generally run with
land unless conditioned otherwise.
COA attaches to approved project and plans, not applicant or
owner.
Preserves approval across ownership transfers. Retained KK §7.01.09, Approvals Run With Land Draft 4 §155.512(D) Pete Low
79 07 · BAR governance Minor changes to approved plans KK Chapter 7 has a general minor-modification process
including 10% thresholds for some changes.
Minor architectural changes require concurrence of Planning
Official and Town Architect; substantial changes return to BAR.
Creates an architecture-specific modification path. Revised KK §§7.01.09, 7.02.11 Draft 4 §155.512(E) Both Medium
80 07 · BAR governance Repeat modification hearings No identical one-BAR-modification-hearing-per-rolling-year limit
identified in KK provisions reviewed.
One formal BAR modification hearing per rolling 12 months;
eligible minor staff changes still allowed.
Reduces serial BAR reconsideration of approved designs. Added No direct counterpart in KK §§7.01, 7.02.11 Draft 4 §155.512(F) Pete Medium
81 07 · BAR governance Recordkeeping and inspections KK requires written approvals, records and building/CO
processes in general LDO.
Controlling COA plans sent to inspection provider; Planning
Official checks exterior before final CO; Building Official retains
TCO authority.
Connects BAR approval to actual constructed exterior. Strengthened KK §7.01.09; §7.02.09 Draft 4 §§155.512(G), 155.513(A)–(D) Both High
82 07 · BAR governance Emergency stabilization No matching express architectural emergency-stabilization
exemption identified in KK BAR section.
Immediate temporary boarding, tarping and shoring may
proceed without prior BAR; permanent reconstruction still
reviewed.
Allows urgent safety measures without bypassing later
architectural review.
Added No direct counterpart in KK §2.03.01(D) Draft 4 §155.513(E) Pete Medium
Page 61 of 64
# Question / reconciliation item Why it matters Source sections Lead Status / notes
1 Adopted BAR composition Confirm latest adopted five-member BAR, Town residency, quorum, terms and
appointments.
KK §6.02.04; Draft 4 §155.509(A) Pete Pending
2 Public meeting / hearing notice Reconcile Town §155.495(J) newspaper publication and statutory hearing rights;
avoid unnecessary local deadlines.
KK §§6.02.04, 7.01.07–.08; Draft 4 §155.509(C) Pete Pending
3 Automatic approval and appeals Determine if existing Town §155.497(C) 45-day deemed approval may be
amended; preserve mandatory state-law rules.
KK §7.01.10; Draft 4 §155.511(C)–(F) Pete Pending
4 Vote, findings and written notice Check approval-only motion, failed-vote denial, record of reasons, 30-day written
notice and effective/appeal dates.
KK §6.02.04; Draft 4 §155.509(E)–(G) Pete Pending
5 Reconsideration and withdrawals Review second-regular-meeting rule, 360-day bar, judicial appeal savings and
ambiguous post-hearing withdrawal trigger.
KK §7.01.04; Draft 4 §§155.509(H), 155.511 Pete Pending
6 Professional review charges Confirm cost estimate/prepayment/refund approach fits adopted fee schedule
and statutory cost recovery.
KK §6.02.04; Draft 4 §155.508 Pete Pending
7 Historic demolition / relocation Reconcile proposed Part II with adopted historic §155.543, designation rights,
demolition by neglect and relocation.
KK §7.03.03; Draft 4 Part II Pete Pending
8 Townhome zoning integration Place six-unit, width, frontage, setbacks and separation in proper zoning
sections; check building/fire standards.
KK §2.03.01(I); Draft 4 §155.504(G) Both Pending
9 Owner authorization / conditional consent Confirm application property-interest authorization, notice to owner, consent to
conditions and approved-plan record.
KK §§7.01.04, 7.01.08–.09; Draft 4 §§155.507, .510, .512 Pete Pending
10 COA/permit/occupancy sequence Check COA validity with building permit, final CO sign-off, Building Official TCO
and enforcement authority.
KK §7.01.09; Draft 4 §§155.512–.513 Both Pending
11 Existing ordinance cross-references Reconcile numbering with existing §§155.315–.316, 155.495–.505,
155.535–.544 and sign rules.
Draft 4 Parts I–V Pete Pending
COUNSEL / TECHNICAL REVIEW PUNCH LIST
Open checks for the next review cycle. These are not requests to reopen settled policy decisions.
Page 62 of 64
12 Draft 4 editorial cross-reference Draft 4 §155.512(C) refers to maintenance exemption in §155.506(A); exemption
appears in §155.506(B). Correct in final draft.
Draft 4 §§155.506(B), 155.512(C) Pete Pending
Page 63 of 64
Type File / issue Explanation Action
Source A Blythewood_LDC_Public_Hearing_Draft_for_Council_05.22.25(1).docx Kendig Keast proposed Land Development Ordinance dated May 22, 2025. Principal comparisons: §2.03.01;
§6.02.04; §§7.01.04–7.01.11; §7.02.11; §7.03.03.
Review source text
Source B Blythewood_BAR_Architectural_Standards_and_Procedures_Working_Draft_04_2
026-11-11.docx
Town BAR Working Draft No. 4, November 11, 2026. Operative proposals in Parts I–III; policy register Part IV;
legal checks Part V; existing KK reconciliation Part VI.
Review source text
Method Source text compared by subject Paraphrases capture policy effect and meaningful differences, not every word or formatting change. Section
references point reviewers to original text. “Added” means no matching provision identified in the cited KK
architecture/BAR provisions.
Limit KK is proposed, not adopted This comparison is not a comparison against the Town’s current adopted code. Existing ordinances, state law
and later BAR membership amendments still require counsel verification.
Status For Ralph and Pete review Review leads indicate whose input is most useful, not a statement of past approval or endorsement. No reviewer
has signed off through this workbook.
Editorial flag Cross-reference in Draft 4 Draft 4 §155.512(C) cites §155.506(A) for maintenance exemption; correct reference appears to be
§155.506(B).
SOURCE NOTES & COMPARISON METHOD
A policy-level comparison prepared from the original files, not a verbatim clause-by-clause redline.
Page 64 of 64
Source: Town of Blythewood website. First collected Nov 21, 2026.