September 11, 2025 BZA Packet
Anderson County · Anderson County · meeting of Sep 11, 2025 · Agenda packets
Open the original document More from Anderson County
Text
Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.
Anderson County Board of Zoning Appeals
Hubert McClure, Chair, District #5 Mike Miller, Vice-Chair, District #2
John Farr, District #1 Russell Barton, District #3
Tony Cirelli, District #4 Brad Swillen, District #6
Debbie Chapman, District #7
AGENDA
September 11, 2025
5:15 PM
Historic Courthouse
101 South Main Street
Anderson, South Carolina
1.) Call to Order: Mr. Hubert McClure, Chairman
2.) Invocation: Mr. Hubert McClure
3.) Approval of Minutes:
A. Minutes will be forthcoming
4.) Public Hearings:
A. Variance to reduce the side yard setback from 50 feet to 20 feet for the
construction of a single-family residence. Located at 5129 Slater Road. /
TMS 118-00-02-120 (Council District 4).
B. Variance to reduce the front setback in two places from 30 feet to 16.5 feet
and 16.9 feet. Located at 116 Leader Drive. / TMS 236-00-07-026 (Council
District 6).
C. Variance to increase the size of a sign. Located at 4026 Clemson
Boulevard. / TMS 121-03-01-032 (Council District 1).
5.) New Business:
A. Board of Zoning Appeals: Discussion of Continuing Education Training
Dates for October 2025
6.) Old Business: None
7.) Other Business: None
8.) Adjournment.
Application for a Variance
Anderson County Land Use Board of Zoning Appeals Meeting
County Council Chambers 2nd Floor-Historic Courthouse
Anderson, South Carolina
September 11, 2025
5:15 PM
Staff Report
Applicant: Marly Young
Owner of Property: Same as above
Property Location: 5129 Slater Rd, Anderson, SC
Council District: Four (4)
Tax Map Number (TMS #): 118-00-02-120
Property Description: TR A2 SLATER RD 1.06 AC
Current Zoning: R- A (Residential Agriculture)
Land Use: Residential
Applicant Request: Applicant is requesting a variance to reduce the side yard setback from 50 feet to 20 feet for
the construction of a single-family residence.
Findings of Fact: Anderson County Code of Ordinances, Under Chapter 48, 5:2.6. Side yard. The minimum
width of a residential side yard shall be 50 feet……
Staff Assessment:
1) The lot is a non-conforming parcel. The 50’ setback makes the lot unbuildable.
2) The lot is only 1.08 acres and with the 50’ side setback makes 8 ft width to build residence
3) The parcel is a new lot of record and falls under the ordinance guidelines for the new setbacks
4) The Applicant can meet all other setback requirements.
5) There will be no adverse effects on adjacent properties, if the variance is granted.
6) If the variance is approved, the Applicant will be required to apply for a residential compliance and
building permit in order to proceed with construction.
Application for a Variance
Anderson County Land Use Board of Zoning Appeals Meeting
County Council Chambers 2nd Floor-Historic Courthouse
Anderson, South Carolina
September 11, 2025
5:15 PM
Applicant: Bryan Yoder
Owner of Property: 54 Technology Dr.
Property Location: 116 Leader Drive, Piedmont, SC 29673
Council District: Six (6)
Tax Map Number (TMS #): 236-00-07-026
Property Description: Commercial Building
Current Zoning: Un-Zoned
Land Use: Com mercial
Applicant’s Request: R educe the front set back in two places from 30' to 16.5' and
16.9'. The property has an irregular shape along the road frontage, with a dogleg turn that
influences the usable area. Along the eastern edge, there is a 270' wide overhead power line
easement that restricts development in that portion of the site. At the rear, a 15' high embankment
further limits the buildable space. As a result, the only practical location for the proposed
addition is along the front and side of the existing building, as shown on the plan.
Findings of Fact: Anderson County Code of Ordinances, Under Sec. 24-433-
Setback lines from roadways. Setbacks shall be 30 feet from the road right-of-way.
Staff Assessment:
1) There is a 270' wide overhead power line easement on the Eastside of the property.
2) At the rear of the property there is a 15' high embankment and Propes Drive that would
limit the buildable space.
3) There will be no adverse effects on adjacent properties if the variance is granted.
4) The applicant will need to contact Building and Codes Department and Development
Standards for applicable permits and compliances.
EX W
EX W
EX W
EX W
EX W
EX W
EX W
EX W
EX W
EX W
EX W
EX W
EX W
EX W
EX W
EX W
EX W
EX W
EX W
EX W
G
G
G
G
G
G
G
G
G
G
G
G
G
FOC
FOC
FOC
FOC
FOC
FOC
FOC
EX S
EX S
UGP
UGP
S
C0
W
Propes Drive
(C-1-41-A)
50' R/W
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP OHP OHP OHP OHP
270' DUKE POWER R/W
PB S-1103 PG 4
PB 97 PG 408
EX W
EX W
EX W
EX W
EX W
EX W
X
X
X
X
X
X
X
X
X
X
X
X
X
X
FOC
FOC
FOC
FOC
FOC
FOC
G
G
G
G
G
G
G
2'X2' DI
GRATE=913.3
IE OUT=910.4
18" RCP
APPROX. 808'± TO
℄
MCNEELY ROAD
X
X X X
X
X
X X X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X X X X X X X X X
4' WIDE DOOR
FFE = 919.44
4' WIDE DOOR
FFE = 918.90'
7.5"x7.5" GICB
GRATE = 918.87'
INV = 917.89'
3" CPP = 918.27'
7.5"x7.5" GICB
GRATE = 918.85'
INV = 918.04'
3" CPP IN = 918.21'
3" CPP OUT = 918.13'
6' CHAIN LINK FENCE
WITH BARBED WIRE
10' TALL ELECTRIC FENCE
10' TALL ELECTRIC FENCE
3" CPP
3" CPP (BURIED)
EX. BUILDING
SEPTIC DRAIN FIELDS
R/W
R/W
Leader Drive(C-1-43-A)
60' R/W
INV = 917.75'
VALLEY
GUTTERS
12" PVC
RAMP
TERMINUS UNKNOWN
SIGN "NO
SMOKING"
CONCRETE
CONCRETE PAD
W/UTILITY
ACCESS
PKO
IPF RR
SPIKE
IPF 1/2"
REBAR
EDGE OF ASPHALT
TELCOM
BOX
H DY
WV
WV
WV
MB
GV
920
919
918
917
916
915
919
920
921
920
919
920
925
930
935
921
921
920
S 85°51'47" W
741.50'
N 24°54'01" W
179.38'
N 64°26'19" E140.58'
N 77°36'37" E
141.17'
16.9'
16.5'
116 LEADER DRIVE116 LEADER DRIVE
Powedersville, South Carolina
SCHEMATICS P.O. Box 686 - Clemson, SC 29633 (864)654-1263
C O P Y R I G H T 2 0 2 5 B Y S I G N A T U R E A R C H I T E C T S : T H I S D R A W I N G I S T H E P R O P E R T Y O F S I G N A T U R E A R C H I T E C T S . D U P L I C A T I O N O R O T H E R U S E F O R A N Y R E A S O N O T H E R T H A N T H E P R O J E C T W H O S E N A M E T H I S T I T L E B L O C K B E A R S , I S S T R I C T L Y P R O H I B I T E D U N L E S S W R I T T E N P E R M I S S I O N I S G R A N T E D B Y T H E A R C H I T E C T .
C O P Y R I G H T 2 0 2 5 B Y S I G N A T U R E A R C H I T E C T S : T H I S D R A W I N G I S T H E P R O P E R T Y O F S I G N A T U R E A R C H I T E C T S . D U P L I C A T I O N O R O T H E R U S E F O R A N Y R E A S O N O T H E R T H A N T H E P R O J E C T W H O S E N A M E T H I S T I T L E B L O C K B E A R S , I S S T R I C T L Y P R O H I B I T E D U N L E S S W R I T T E N P E R M I S S I O N I S G R A N T E D B Y T H E A R C H I T E C T .
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHPOHPOHPOHPOHPOHPOHPOHPOHPOHP
OHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHP
OHP
OHP
OHP
OHP
OHP
EX W
EX W
EX W
EX W
EX W
EX W
EX W
EX W
EX W
EX W EX W EX W EX W EX W EX W EX W EX W EX W EX W EX W EX W EX W EX W EX W EX W EX W EX W
EX W
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X X X X X X X X X X X X X X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T T
T
T T T
T T T T T T T T
G
G
G
G
G
G
G
G
G
G
SF SF SF SF SF SF SF
SF
SF
SF
SF
SF
SF
SF
SF
IE=909.8
18" RCP
2'X2' DI
GRATE=913.3
IE OUT=910.4
18" RCP
24" RCP
IE=907.2
IE=907.7
YI
RIM=917.3
15" HDPE
IE=913.5
IE=910.215" RCP
IE=908.5
(SILTED)
IE=903.6
IE=902.9
15"
RCP
E
E
E
TMS #2360007025
N/F CONNER HOLDINGS, LLC
DB 4633 PG 82
LEADER DRIVE(C-1-43A)
60' PUBLIC R/W
PROPES DRIVE
(C-1-41A)
50' PUBLIC R/W
20
20
17
14
17
24.0'
20.0'
20.0'
9.0'
9.0'
24.0'
9.0'
20.0'
24.0'
20.0'
R5'
R20'
R5'
R5'
R5'
R5'
R20'
R5'
R5'
R5'
R5'
R5'
CONTRACTOR TO STRIPE
EXISTING PAVEMENT
R5'
R5'
R5'
R5'
10.0'
15.0'
10.0'
10.0'
20.0'
BUILDING LOCATION IS
NOT UP FOR APPROVAL
ON THIS SUBMITTAL
TREES TO NOT GROW HIGHER THAN 15'
AT MATURITY (TYP. ALL TREES)
POLYMED PARKING
EXTENSION
CITY OF PIEDMONT
ANDERSON COUNTY
SOUTH CAROLINA
CHECKED:
DRAWN BY:
JOB NUMBER:
REV #
JWW
BHB
24164
RIDGEWATER
ENGINEERING & SURVEYING
PO BOX 806
ANDERSON, SC 29622
(864) 226-0980
RIDGEWATERENG}COA
DATE COMMENT
REL 0 06-19-2024 RELEASED FOR REVIEW
SHEET
THIS DRAWING AND THE DESIGN SHOWN THEREON ARE THE
PROPERTY OF RIDGEWATER ENGINEERING & SURVEYING, LLC.
THE REPRODUCTION, COPYING OR USE OF THIS DRAWINGWITHOUT WRITTEN CONSENT IS PROHIBITED AND ANY
INFRINGEMENT WILL BE SUBJECT TO LEGAL ACTION.
REL 1 06-20-2024 UPDATED PER ANDERSON COUNTY
COMMENTS
REL 2 07-09-2024 UPDATED PER DUKE ENERGY
COMMENTS
REL 3 07-24-2024 UPDATED PER DUKE ENERGY
COMMENTS
1 in = ft.SCALE:
030 30
30
15
GRID NORTHS.C.S.P.C. NAD 83 (2011)NAVD 88 (CONUS 12B)
SITE NOTES:
1. DIMENSIONS ARE TO THE FACE OF CURB, EDGE OF
PAVEMENT, FACE OF BUILDING OR PROPERTY LINE.
2. R DENOTES FACE OF CURB OR EDGE OF PAVEMENT RADIUS.
ALL RADII ARE 5-FEET UNLESS NOTED OTHERWISE.
3. ALL WORK IN THE R/W SHALL BE VERIFIED WITH THE
APPROVED ENCROACHMENT PERMIT PRIOR TO COMMENCING
WORK.
4. TOTAL AREA OF SITE = 3.97 ACRES
TOTAL AREA DISTURBED = 0.9 ACRES
5. AN ELECTRONIC FILE OF THE SITE PLAN SHALL BE MADE
AVAILABLE FOR STAKING PURPOSES.
ZONING REQUIREMENTS:
SITE ZONING: UNZONED
BUILDING SETBACKS:
FRONT RIGHT LEFT REAR
DENOTES LIMIT OF DISTURBANCE
00 DENOTES NUMBER OF PARKING
STALLS IN A ROW
TRAFFIC FLOW
LOD
C DENOTES COMPACT PARKING STALLS
EOP EDGE OF PAVEMENT
BOC BACK OF CURB
R/W RIGHT-OF-WAY
R RADIUS
C - 2
SITE
PLAN
30' 15' 15' 30'
DENOTES ASPHALT PAVEMENT
REFER TO ROAD CROSS-SECTION
SITE LEGEND
IMPERVIOUS / PERVIOUS AREAS:
TOTAL AREA = 3.97 ACRES
MIN PERVIOUS AREA = 0.79 ACRES (20%)
SHOWN PERVIOUS AREA = 1.79 ACRES (45.1%)
MAX IMPERVIOUS AREA = 3.18 ACRES (80%)
IMPERVIOUS AREA = 2.18 ACRES (54.9%)
CANOPY TREE (5 TOTAL, AT LEAST 6' IN HEIGHT,
MAXIMUM OF 15' MATURE HEIGHT PER DUKE ENERGY)
07-24-24
July 9, 2025
Anderson County Development Standards
401 East River St
Anderson, SC 29624
RE: Variance Application – 116 Leader Dr, Piedmont SC
Owner Permission for Variance Application
To Whom It May Concern,
As the property owner of 116 Leader Drive, Piedmont SC (TMS 2360007026) I am granting
permission to allow the applicant to apply for the requested variance.
Sincerely
Application for a Variance
Anderson County Land Use Board of Zoning Appeals Meeting
County Council Chambers 2nd Floor-Historic Courthouse
Anderson, South Carolina
September 11, 2025
5:15 PM
Staff Report
Applicant: Dexter Rucker
Owner of Property: Mark Raynock
Property Location: 4026 Clemson Blvd., Anderson
Council District: One (1)
Tax Map Number (TMS #): 121-03-01-032
Property Description: PT Lot 9 Clemson Blvd
Current Zoning: C-2 (Highway Commercial)
Land Use: Commercial
Applicant’s Request: Applicant is requesting a variance to increase the size of the permitted sign for the
placement of a wall sign on building.
Findings of Fact: Anderson County Code of Ordinances, Under Sec. 24-245. - Permitted signs
(2) Permanent business identification signs attached to buildings. a.Allowable area.
1.If there is no freestanding business identification sign on the developed site, lot or parcel, one permanent business
identification sign may be attached to the building provided it contains not more than 1½ square feet of total signage area
per linear foot of principal building frontage.
2. If there is a freestanding business identification sign on the developed lot, parcel or site,
one permanent business identification sign containing not more than one square foot of
total signage area per linear foot of principal building frontage may be placed, erected or
displayed on said building.
Staff Assessment
1) The Applicant submitted an application for a front wall sign for the front of the building.
2) The store building front is 41 Linear Feet, making the First sign submission at 224 by 36 too large for
the building frontage.
3) The Applicant resubmitted the diagram of 146 by 25 to be in compliance with the ordinance. The sign
application was approved and permitted.
4) The Applicant is now asking for the larger sign to be approved because the approved sign would leave
wasted space on the building frontage.