RecordWell Data

Packett PC_Feb2026

Edgefield County · Edgefield County · meeting of Feb 11, 2026 · Agenda packets

Open the original document More from Edgefield County

Text

Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.

Edgefield County Planning Commission County Council Chambers February 12, 2026 Work Session 5:00 PM Meeting 6:00 PM The next Planning Commission Meeting is scheduled for March 12, 2026 Edgefield County Planning Commission Work Session Agenda County Council Chambers February 12, 2026 5:00 PM This agenda may be modified at any time prior to or during the meeting described herein. The meeting may begin after the advertised start time if a reasonable adjustment to the advertised start time is needed for any reason. I. Call to Order II. Guest Speakers III. Old Business a) Review “Restrictions on Land Disturbance Activity for Major Residential Subdivisions” requested as an amendment to the Tree Preservation Ordinance being presented to County Council for consideration. b) Review corrections to proposed Data and Crypto Mining Centers ordinance. IV. New Business a) Harmoni Towers AssetCo. LLC, is proposing the installation of a 315ft guyed tower and associated antenna, located at the corner of Luke Bridge Rd and Hyw 191 in Johnston. AT&T is looking to provide/enhance their network and to provide improved cellular data and coverage. Harmoni Towers AssetCo. LLC and AT&T are seeking a Conditional Use Permit for the telecommunication Towers based on the criteria and the general provisions outlined in Section 24-75- Communication Towers and Antennas of the Edgefield County Ordinance. 3 V. Adjourn To watch the Planning Commission Work Session live: Subscribe to our YouTube Account – Edgefield County Government. You can be notified of upcoming live streams. The next Planning Commission Meeting is scheduled for March 12, 2026. The Planning Commission is scheduled to meet on the second Thursday of each month at 5:00 p.m. for a work session and at 6:00 p.m. for the meeting at the Edgefield County Council Chambers, located at 225 Jeter St., Edgefield, SC. These meetings are subject to cancellation or change without prior notice. The public will be notified of any cancellation or change. Individuals requiring special assistance or a sign interpreter to participate in the meeting are asked to notify the Building & Planning Department 48 hours before the meeting at (803) 637-4073. Any questions regarding the Planning Commission should be directed to the County’s Planner, April Morgan Amorgan@edgefieldcounty.sc.gov 4 Proposed Data and Crypto Mining Center Ordinance - Draft Recommended to first amend Section 24-31 (Land Use Table) to allow data centers in ID(Industrial) zoned areas of Edgefield County and subject to certain conditional regulations. Potential Conditional Use Regulations to be added to Chapter 24 in addition to being restricted to Industrial areas only. Defined Terms of Edgefield County Closed loop system: A system that constantly reuses and recycles an initial load of water within its operation, significantly reducing the draw on external water sources and minimizing wastewater discharge. A closed loop system shall not use evaporative cooling, and may consist of methods including, but not limited to, air-cooled (dry) cooling, rear door heat exchanger cooling, hybrid dry economizer cooling, direct-to-chip cooling, or immersion cooling. Data center: A physical room, building, or facility that houses infrastructure for building, running, delivering, or transmitting technological applications and services, or for storing and managing the data associated with those technological equipment, applications, or services. Data Center, Campus: A data center campus shall include a singular development that has more than one (1) data center with a total development area of a minimum of 500,000 square feet. Load: The total power consumed by servers, storage, cooling, ventilation, generators, and other networking devices that operate within a data center site. Megawatt (MW): The unit of measurement for electricity that is equivalent to one million watts. This is used to measure the total power consumption of data centers. Substations: An electric system facility that converts higher voltages to lower voltages within or separate from a data center to generate sufficient power at maximum efficiency; can operate independently for dedicated site once directly connected to transmission line. Square footage, data centers: The square footage of a data center shall include the total square footage of each floor in the data center development, the square footage of any supporting uses, and the square footage of any additional exterior equipment, such as substations, electrical yards, mechanical yards, and any other exposed equipment, located within property boundaries Crypto Mining A crypto mining center (or farm) is a specialized, industrial-scale facility containing a large number of high-powered computers—usually Application-Specific Integrated Circuits (ASICs) or powerful GPUs—dedicated solely to validating blockchain transactions and generating new cryptocurrency units, such as Bitcoin. These centers operate 24/7, requiring significant, constant 5 electricity for processing and intense cooling systems. Its purpose is primarily to solve complex cryptographic algorithms (Proof of Work) to earn cryptocurrency rewards. A. Permitted location 1. Data centers shall only be permitted in ID (Industrial Zoned) areas and shall be specifically forbidden in un-zoned portions of the unincorporated areas of the County. 2. No Data Center shall be permitted within 1000 feet of a single or multi-family residence. 3. Data centers and Campus data centers shall provide a 20-foot-wide landscaped buffer. It shall be located around the data center development, and may be within the 100-foot transitional buffer. A minimum of one canopy tree shall be planted for every 30 feet of property frontage if the subject site abuts publicly accessible right-of-way or non-industrially zoned properties. These improvements may be located within the required 100-foot transitional buffer described in (Sec. 27- 4.2.64 (B)5) if applicable 4. Distance shall be measured from the edge of any building, substation, drive, street, parking lot, structure or improvement to the nearest property line. B. Architectural and landscaping design requirements 1. Where visible from a publicly accessible road or right-of-way, a Medium, Major, or Campus data center shall have a minimum of thirty (30) percent of the width of the front façade of any buildings at the ground level consist of fenestration. Decorative windows, architecturally glazed windows and painted or applied decorative murals shall be permitted to count towards fenestration requirements after ten percent (10%). a) A mural shall be classified as a very large image, such as a painting, applied directly to a wall. Murals are signs that promote public art and shall not used for advertising. 2. A minimum of ten percent (10%) of the width of side and rear facades shall incorporate decorative windows or architecturally glazed windows. 3. The following materials shall not be utilized on the building façade: aluminum siding; corrugated steel; vinyl siding; plywood; pressed wood products; synthetic stucco; or unfinished concrete block. 6 4. All data centers shall have unified landscape and architectural elements. C. Operation requirements. 1. Substations, electrical yards, mechanical yards, and any other exposed equipment shall not be located between the building and a publicly accessible road or right- of-way and shall be screened from any adjacent publicly accessible street, private street, trail, or park. 2. All lighting other than street and pedestrian scale lighting shall have “Dark Sky” design. There shall be no spillover from the fixture onto surrounding properties, including the street. All lights and poles shall have a permanent black finish. 3. All cooling and ventilation equipment within property boundaries shall operate on a closed-loop system. 4. All cooling, ventilation, and other external equipment used to operate the facility shall not be located between building and publicly accessible rights-of-way, unless located on the rooftop of any data center development or building within property boundaries. 5. Substations associated with the operation of a data centers shall be subject to the following requirements: a) The substation shall be at least fifty (50) feet from the public right-of-way. b) The substation shall be screened with a minimum eight (8) foot tall wall from any adjoining property or publicly accessible street. c) The substation shall not involve the storage of vehicles or service equipment. Generator Maintenance requirements. 1. Any generators on the property shall comply with U.S. Environmental Protection Agency (EPA) New Source Performance Standards (NSPS) of at least Tier 4 emission standards. a) Testing for these generators shall not exceed 10 hours per month. b) Testing for these generators shall only occur between the hours of 9:00 a.m. and 5:00 p.m. c) Generators shall be enclosed by a sound attenuation for noise reduction and to reduce pollution. 2. Except for generator testing or commissioning activities, generator use is limited to backup/emergency use only. D. Application requirements. 1. All applications for a data center shall, in addition to any other application requirements of this code, provide the following information: a) Applicants shall provide a letter of intent from the relevant utility provider(s), confirming that preliminary coordination has occurred and that service to the proposed facility is technically feasible subject to final engineering review. b) Noise Impact Assessment: A Noise Impact Assessment shall be required as part of the permitting process for any proposed data center development and assessed at a distance of 500 feet from the data center development. The Noise Impact Assessment shall: 7 i. Define the scope of the assessment, including the geographic area, the noise sources to be studied, and the specific objectives of the assessment for the proposed development. ii. Measure pre-operation ambient noise, or the existing background noise before any server equipment is installed, and provide acoustic mitigation strategies if noise level is proposed to exceed 60 dB during any hours of the day or night once equipment for data center development is in operation. c) Water Consumption and Sustainability Plan: A Water Consumption and Sustainability Plan shall address conservation and scarcity, outlining the total water requirement of the data center, including cooling needs, and any strategies to reduce or mitigate excessive water usage. The plan shall demonstrate that the water usage shall not significantly strain the County’s water supply. d) Energy Consumption and Sustainability Plan: An Energy Consumption Sustainability Plan shall contain the estimated energy load before construction and the daily operational load once constructed. This assessment shall outline: i. Estimates of peak electricity demand and strategies for mitigating strain on local power infrastructure ii. Proposed improvements or alternatives to minimize the need for additional transmission lines and the designated power provider iii. The use of sustainable alternatives for on-site water or power generation, such as solar panels, rooftop cisterns, small-scale wind turbines, or other renewable energy sources which shall offset at least 10% of total power or water usage. iv. A decommissioning plan, in the event data infrastructure is not sold or transferred, for recycling all on-site electronic infrastructure through certified recyclers that follow Responsible Recycling (R2) Standard for Electronics Recyclers and/or e-Stewards® Standard for Responsible Recycling and Reuse of Electronic Equipment. An approved decommissioning plan shall be provided to the Planning Director for county records. e. Transmission Line Impact Assessment: A Transmission Line Impact Assessment shall identify the need for new or upgraded transmission lines to meet the data center’s electricity requirements. This assessment shall include the potential environmental impact on public land, including tree removal from county-owned land and rights-of- way. This plan shall also include information on the planned substation’s location and shall show the screening mechanism(s), which shall include a minimum of an eight (8) foot tall decorative brick wall if potentially visible by the public. 8 f. Before final approval by Edgefield County all stormwater and environmental approvals from the South Carolina Department of Environmental Services will have to be submitted to the Planning Director. 2. Additional Information: Any additional information requested by Edgefield County’s Planning Department shall be submitted before the application is deemed complete. 3. The owner and/or operator is required to submit an annual compliance report that details any changes to and continuation of all assessments submitted with an application demonstrating compliance and monitoring of all applications requirements and conditions of zoning to the County’s Planning Director no later than the first of January of each year. 4. The burden of showing compliance with supplemental requirements and/or conditions of zoning is on the applicant and/or owner of the property or use. A. Decommissioning Upon the decommissioning of a Data or Crypto Mining Center, a detailed, documented approval from any and all applicable regulatory authority, shall be provided to the Edgefield County Planning Director for review and county record. 9 Memorandum To: Edgefield County Planning Commission From: April Morgan, Edgefield County Planner Date: February 12, 2026 Re: Land Development Application (Telecommunication Tower) Applicant: Harmoni Towers AssetCo. LLC Property Owner: Stone Mountain Property Holdings LLC Property Address: (or) Location: Corner of Luke Bridge & Highway 191 Parcel ID: 192-00-00-072-000 Property Size: 4.32 acre Zoning: UN-Zoned Proposed Use: Commercial Sewer/Septic: NA Water: NA Land Development Description Harmoni Towers AssetCo. LLC, is proposing the installation of a 315ft guyed tower and associated antenna and equipment. AT&T is looking to provide/enhance their network and to provide improved cellular data and coverage. Harmoni Towers AssetCo. LLC. and AT&T are seeking a Conditional Use Permit for the telecommunication Towers based on the criteria and the general provisions outlined in Section 24-75- Communication Towers and Antennas of the Edgefield County Ordinance (SEE BELOW). Compliance with County Land Development Ordinances • Permitted Use in Zoning District -Conditionally Permitted • Application process for Land Development -Completed 10 Compliance with County Comprehensive Plan Rural Agricultural Farming / General Development, Large Lot Single Family Residential, Light Industrial Commercial uses Heavy industry, Small Lot Residential Approval by Other Regulatory Entities • DHEC Storm Water / Sediment Control Pending • DHEC Waste Water Control NA 11 • ECWSA Tap Approval NA • Electric Utility Pending • SCDOT Encroachment Pending Communication Tower Ordinance Article III. – Conditional Use The regulations contained in this article are intended to minimize the impact and improve the siting of uses, buildings, and projects whose design and/or operational characteristics could adversely affect surrounding property and environmental conditions. To this end, standards and criteria over and above those set forth elsewhere in this chapter are imposed herein on all conditional uses listed on table 1 in Sec. 24-75. - Communication towers and antennas. (a) Telecommunication facilities should be located so as to minimize adverse, aesthetic and visual impacts on the land, property, buildings, and other facilities where wireless communication devices are considered. New telecommunications facilities, towers, or antennas shall adhere to the following regulations. (b) Prior to approval of any application for a permit for a new telecommunication facility a public hearing shall be held by the county planning commission, notice which shall be published in the county no less than ten calendar days prior to the hearing. Also ten days prior to the public hearing this notice will be given to all landowners within 500 feet of the property. (c) After the public hearing and formal consideration of the application, the county planning commission may determine in writing the approval, approval with conditions, or denial of a permit. The planning commission can deny the location and placement of a telecommunication facility if it is a substantial detriment to the surrounding area. (d) Definitions: Applicant means any wireless service provider or agent submitting an application for a permit for a telecommunications facility. Fall zone means the maximum area (the furthest distance from the tower base) in which a telecommunications facility will collapse in the event of a failure, usually less than the total height of the structure. This zone must be defined by a professional civil or structural engineer licensed in the state. FCC means the Federal Communications Commission, or its duly designated and authorized successor agency. Height means, when referring to a tower or other structure, the distance measured from the pre- existing grade level to the highest point on the tower or structure, even if said highest point is an antenna or lightning protection device. 12 Telecommunications means the transmission and/or reception of audio, video, data, and other information by wire, radio frequency, light, and other electronic or electromagnetic systems. Tower means any structure designed primarily to support an antenna for receiving and/or transmitting a wireless signal. A "freestanding tower" shall mean a monopole or self-supporting tower. A "guyed tower" shall mean a tower supported and stabilized through the use of guy wires. (e) (1) All new towers shall be designed to accommodate additional antennas equal in number to the applicant's present and future requirements. (2) All applicable safety code requirements shall be met. (3) Towers or antennas shall not be painted or illuminated unless otherwise required by state or federal regulations. (4) No tower shall be located in any wetlands. (5) No tower or antenna shall be located within 1,000 feet of an existing tower or antenna, unless the applicant certifies that the existing tower does not meet the applicant's structural specifications and applicant's technical design requirements, or that a collocation agreement could not be obtained. (6) Towers or antennas shall be exempt from the maximum height requirements of this chapter, except as provided for in section 24-203 . (7) Towers or antennas shall be located such that adequate setbacks are provided on all sides to prevent the tower's fall zone from encroaching onto adjoining properties. Should this fall zone encroach onto another property, a recorded easement may be prepared and signed by the adjacent property owner to ensure that no structure will be built within the fall zone. (8) Signage on communication towers and/or antennas. a. No advertising of any type may be attached to a communication tower; however, a communication tower and/or antennas may be placed upon an outdoor advertising sign provided the height of the sign is increased not more than 20 feet. b. The placement of a communication tower and/or antennas upon an outdoor advertising sign shall not change the principal nature or classification. c. A sign no larger than four square feet shall be placed in a visible location identifying the owner and operator of each antenna as well as their emergency phone number(s). 13 (9) Communication towers shall be removed at the operator's expense within 120 days of the date such tower ceases to be used for its intended purpose. (10) Permit requirements for the erection or replacement of a tower or antenna shall be accompanied by the following: a. One copy of engineered stamped typical specifications for proposed structures and antenna, including description of design characteristics and material. b. An engineered stamped site plan drawn to scale showing property boundaries, tower location, tower height, guy wires and anchors, existing structures, fall zone (as determined by a structural engineer, licensed and certified in South Carolina), photographs or elevation drawings depicting typical design of proposed structures, parking, fences, landscape plan, and existing land uses on adjacent property; [site plan not required if antenna is to be mounted on an approved existing structure]. c. A current map or update of an existing map on file, showing locations of applicant's antenna, facilities, existing towers, and proposed towers which are reflected in public records, serving any property. d. Identification of the owners of all antenna and equipment to be located on the site. Allow Edgefield County to share the wireless telecommunications facility for emergency services and government use at no cost. e. Written authorization from the site owner for the application. f. Evidence that a valid FCC license for the proposed activity has been issued. g. The applicant shall furnish a visual impact assessment, which shall include digital pictorial representations of "before and after" views from key roads, residential, commercial or other locations where the site is visible to a large number of individuals. The applicant shall provide a map showing the locations of where the digital pictures were taken and the distance from the proposed structure. h. A written agreement to remove the tower and/or antenna within 120 days after cessation of use. i. A certificate from a registered engineer that the proposed facility will contain only equipment meeting FCC rules, together with written indemnification of the county and proof of liability insurance or financial ability to respond to claims up to $1,000,000.00 in the aggregate which may arise from operation of the facility during its life, at no cost to the county. j. The applicant shall demonstrate and provide in writing and/or by drawing how it shall effectively screen from view the base and all related equipment and structures of the proposed wireless facility. 14 k. A report from a structural engineer registered in South Carolina showing the tower antenna capacity by type and number, a certification that the tower is designed to withstand winds in accordance with ANSI/EIA/TIA 222 standards and a determination of the fall zone. l. A written agreement to allow other users to co-locate on the tower and documentation that the tower will be designed to allow it. (11) The provisions of this section shall not apply to amateur radio, citizens band radio, or television reception towers, masts and/or antennas. (12) All telecommunication facilities and antennas shall be located, fenced or otherwise secured in a manner that prevents unauthorized access. (13) The holder of a permit issued under this section shall comply with all applicable state and federal laws, regulations and rules pertaining to the wireless telecommunications facility for which the permit was issued. Planning Commission Action Planning Commission shall review the preliminary plat. After final discussions, the item will be put to a vote to determine the Planning Commission’s recommendation of approval or denial of the preliminary plat. 15 Land Development Area Aerial: (Image, Streets, Property red outline) 16 Land Development Property 17 Land Development Preliminary Plan 18 19 Restrictions on Land Disturbing Activity for Major Residential Subdivisions (a) Major Residential Subdivision developments should be adapted to the natural contours of the land. (b) Mass grading of Large residential subdivisions should be limited to road right-of-way, public utility easements, stormwater detention / retention facilities, and no more than 5 concurrent lots. (c) Cut and fill slopes shall be no steeper than 2 feet long to 1 foot vertical. This shall also apply to detention / retention ponds. (d) Topsoil stripped during construction must be stockpiled and reapplied to disturbed areas during final grading and prior to final grassing. (e) Developments other than single family residential. Multi-family, commercial and industrial developments normally require a much flatter topography than single family residential. Therefore, portions of non-single family residential developments may be mass graded in order to meet the requirements of the project. However, the design shall be as compatible with the existing topography and attempt to leave as much natural vegetation in place as practical. Definitions: Mass Grading: Land disturbance including earth moving over a large area which results in an alteration of the natural contours of the land. Major Residential Subdivision: Topsoil Preservation: Stockpiling stripped topsoil onsite to be reapplied at final grading and prior to revegetation of the site. 20 Edgefield County Planning Commission Meeting Agenda County Council Chambers February 12, 2026 6:00 PM This agenda may be modified at any time prior to or during the meeting described herein. A vote may be held on all agenda items. The meeting may begin after the advertised start time if a reasonable adjustment to the advertised start time is needed for any reason. VI. Call to Order VII. Invocation VIII. Pledge of Allegiance IX. Approval of Agenda A. Approval of February 12, 2026 Meeting Agenda X. Approval of Minutes A. Approval of December 11, 2025 Work Session Meeting Minutes B. Approval of December 11, 2025 Meeting Minutes C. Approval of January 8, 2026 Work Session Minutes XI. Reports Staff Reports XII. Guest Speakers XIII. Public Hearing Chairman: James Burt – Dist. I Members: Dustin Doolittle – Dist. II Vice-Chairman: Lisa Whitaker- Dist. III Karlene Butler– Dist. IV At Large: Autumn Eubanks At Large: Tracy Walsh 21 This portion of the Planning Commission's regular Meeting allows for comments from citizens regarding Public Hearing items on the Agenda during the regular meeting. Citizens may sign up to speak on these matters. Interested citizens may sign up to speak on a list maintained by the County Planner before the meeting. Each citizen shall be eligible to speak for a maximum of 5 minutes. All citizens wishing to speak during the public hearing shall be subject to recognition by the presiding officer and shall address the presiding officer directly. Written comments may be submitted to the County Planner before the meeting, which will be read during the Public Hearing Comment Section. XIV. Old Business a) Vote and final discussion regarding the request to add “Restrictions on Land Disturbance Activity for Major Residential Subdivisions” as an amendment to the Tree Preservation Ordinance being presented to County Council for consideration. b) Vote and final discussion on a recommended Data & Crypto Mining ordinance. XV. New Business c) Vote and final discussion regarding the preliminary approval of Harmoni Towers AssetCo. LLC, proposed installation of a 315ft guyed tower to be located off of Lick Fork Road in Edgefield (parcel ID #073- 00-00-010-000). XVI. Adjournment The next Planning Commission Meeting is scheduled for March 12, 2026. The Planning Commission is scheduled to meet on the second Thursday of each month at 5:00 p.m. for a work session meeting and at 6:00 p.m. for the regular meeting at the Edgefield County Council Chambers located at 225 Jeter St., Edgefield, SC. These meetings are subject to cancellation or change without prior notice. The public will be notified of any cancellation or change. Individuals requiring special assistance or a sign interpreter to participate in the meeti ng are asked to notify the Building & Planning Department 48 hours before the meeting at (803) 637- 4073. Any questions regarding the Planning Commission should be directed to the County’s Planner, April Morgan, at amorgan@edgefieldcounty.sc.gov 22

Source: Edgefield County website. First collected Oct 13, 2026.