RecordWell Data

Design Review Board Meeting — Agenda Packet

Town of Hilton Head Island · Beaufort County · Design Review Board · meeting of Sep 23, 2026 · Agenda packets

Open the original document More from Town of Hilton Head Island

Text

Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.

Town of Hilton Head Island Design Review Board Meeting Wednesday, September 23, 2026, 2:30 PM 1 Town Center Court, Hilton Head Island, SC Benjamin M. Racusin Council Chambers The Design Review Board meeting will be held in person at Town Hall in the Benjamin M. Racusin Council Chambers. 1. Call to Order 2. Adoption of the Agenda 3. Approval of the Minutes a. Regular Meeting Minutes of August 26, 2026 4. Unfinished Business 5. New Business a. DRB-000872-2026 - 1 Brams Point Road - Alteration/Addition - Clubhouse Expansion 6. Public Comment - Non Agenda Items 7. Board Business 8. Staff Reports 9. Adjournment FOIA Compliance: Public notification of this meeting has been published, posted, and distributed in compliance with the South Carolina Freedom of Information Act and the requirements of the Town of Hilton Head Island. In accordance with the requirements of Title II of the Americans with Disabilities Act of 1990 ("ADA"), the Town of Hilton Head Island will not discriminate against qualified individuals with disabilities on the basis of disability in its services, programs, or activities. Auditory accommodations are available. Any person requiring further accommodation should contact the Town of Hilton Head Island ADA Coordinator as soon as possible but no later than 48 hours before the scheduled event. Page 1 of 55 Municipal Association of South Carolina (MASC) Civility Pledge: “I pledge to build a stronger and more prosperous community by advocating for civil engagement, respecting others and their viewpoints, and finding solutions for the betterment of my city or town.” Page 2 of 55 Town of Hilton Head Island Design Review Board Meeting Minutes 8/26/2026 Page | 1 Town of Hilton Head Island DESIGN REVIEW BOARD MEETING Wednesday, August 26, 2026, 2:30 PM Minutes 1. Call to Order Chair Parker called the meeting to order at 2:30 pm. Present were Chair Parker, Vice-Chair Foss, Annette Lippert, Megan Fitzpatrick, Judd Carstens, Patty Pastor and Todd Theodore. 2. Adoption of the Agenda Patty Pastor moved to approve the agenda as presented. Judd Carstens seconded. The motion passed unanimously. 3. Approval of the Minutes a. Regular Meeting Minutes of August 12, 2026 Megan Fitzpatrick moved to approve the minutes of August 12, 2026. Cathy Foss seconded. The motion passed unanimously. 4. Unfinished Business 5. New Business a. DRB-000747-2026 – 15 Trellis Court – Alteration/Addition Chair Parker and Judd Carstens left the dais due to a conflict. Tom Smith, Assistant Planning Director, presented 15 Trellis Court (Alteration/Addition) as included in the agenda packet. The applicant answered questions from the board. Annette Lippert moved to approve with the following conditions — noting that all the changes shall be resubmitted to staff for review by staff and two board members. The conditions were: include all of staff's comments, color board, details shall be revised such that there is no 7 inch exposure siding, the horizontal canopy with the tie back colors shall be defined, the railings and ramp colors shall be defined, the condenser screen detail shall be provided with color notation, the trash enclosure color shall be noted, the gutter color shall be noted, the PLT light fixture shall be revised to a higher end fixture for the entry and the entire entry canopy element shall be studied in proportions - post sizes, heights of wear, transitions of heights. Megan Fitzpatrick seconded. The motion passed with a vote of 5-0. Chair Parker and Mr. Carstens did not vote due to a conflict. 6. Public Comment - Non Agenda Items 7. Board Business The Board asked if there was an update on potential candidates for the Design Review Board. Trey Lowe advised the board he would find out and report back at the next meeting. Page 3 of 55 Town of Hilton Head Island Design Review Board Meeting Minutes 8/26/2026 Page | 2 8. Staff Reports a. Update on Design Guide. Trey Lowe advised the Board that over the summer they had been going through the Priority 1 LMO Amendments. Because of the prioritization of those, some of our other priority items, like the Design Guide have shifted back. That does not mean we have not been working on the Design guide. We have been doing that over the summer. We have completed a draft version and as soon as I have been able to review it we will schedule time to go over them. b. Report on minor projects not coming to Design Review Board. Tom Smith provided the Board with a list of minor projects that did not come before the Board for approval. 9. Adjournment The meeting was adjourned at 3:37 pm. Page 4 of 55 SPANISH WELLS CLUB ADDITION 1 BRAMS POINT ROAD “ADDITION” REVIEW SEPTEMBER 23, 2026 DRB-000872-2026 Page 5 of 55 SPANISH WELLS CLUB ADDITION 1 BRAMS POINT ROAD PROJECT NARRATIVE Page 6 of 55 II ANDEDSON CONSTRUCTION COMPANY N C . DESIGN REVIEW NARRATIVE Spanish Wells Clubhouse Renovation and Expansion Project: Spanish Wells Clubhouse Review Basis: Town of Hilton Head Island Design Guide Purpose: Exterior renovation, upgrade, and expansion Project Intent and Island Character Spanish Wells Club proposes to refurbish , upgrade, and expand the existing clubhouse so that it can better serve its members , guests, and community functions . The work has been designed as a cohesive improvement to an established building, not as an unrelated or attention-seeking architectural statement . Its form , mater ials, colors, and exterior details draw from the architectural character already present within the Spanish Wells community and are intended to remain subordinate to the natural setting. This approach directly supports the Design Guide's central vision of a harmonious relationship among sensitive site planning, skillful architecture , and preservation of the Island's landscape character (Design Guide, pp. 1 and 4). The existing site context - including the clubhouse's relationship to Spanish Wells Road, the waterfront , the elevated bluff , established vegetation , and surrounding development - has guided the exterior design. The proposed improvements enhance the usefulness and appearance of the existing clubhouse while maintaining continuity with the neighborhood and avoiding a building that appears foreign to its setting . Form, Mass, Scale, and Context The proposed covered roof over the existing patio adds depth , shade, and shadow to the exterior elevation and provides a clear transition between the building and the outdoor gathering area. This roof element breaks up the fai;ade, reduces the appearance of a single unrelieved plane, and establishes a comfortable human scale at the patio . It is designed as a subordinate extension of the existing clubhouse rather than a dominant new mass. These features are consistent with the Design Guide's preference for articulated wall and roof forms , proportional overhangs, porches, terraces, and canopies that provide visual interest and reinforce pedestrian scale (Design Guide, pp. 13-14 ). The renovation and expansion retain the clubhouse as the visual and functional center of the site without overpowering nearby residences, roadway views, or the waterfront setting . The proposed work uses a horizontal emphasis, sheltered outdoor space, and coordinated architectural details to reduce apparent mass and to remain compatible with the scale and established vernacular of Spanish Wells. Page 1 Page 7 of 55 Materials, Details, and Color The exterior palette uses high-quality , durable materials suited to Hilton Head Island's coastal environment. Principal improvements include a low-gloss, non-reflective dark bronze metal roof and Savannah gray brick at the exterior wainscot and existing chimney . Metal and brick are identified in the Design Guide as appropriate local materials. Their combined use creates compatible texture , avoids a single-mate rial fa~ade, and follows the Guide's logical arrangement of materia ls by placing visually heavier masonry at the base beneath lighter wall materials (Design Guide, p. 15). The Savannah gray brick at the wainscot and chimney visually ties the elevations together and makes the existing chimney an integrated architectural feature . The dark bronze roof , muted gray masonry, and existing wall colors form a subdued, earth-toned palette with subtle contrast. The scheme avoids bright , saturated , or highly contrasting colors and allows the clubhouse to blend with the surrounding tree canopy, bluff , and neighboring development , consistent with the Design Guide's color standards (Design Guide, p. 16). Roadway and Waterway Views The project gives comparable design attention to all visible elevations, including those seen from Spanish Wells Road and from the water. From the roadway, the coordinated roof , brick wainscot , chimney treatment, and covered patio will read as a unified renovation compatib le with the surrounding community . From the water , the most apparent new elements will be the covered patio roof , the dark bronze metal roofing , and the Savannah gray brick at the chimney and wainscot. The height of the existing bluff and established vegetation will substantially screen the lower portions of the building and limit the perceived scale of the improvements . Any portions remaining visible from the water will use the same coordinated materials, colors, and details as the primary elevations, consistent with the Guide's direction that all sides of a structure receive equal design consideration (Design Guide, p. 12). Landscape Integration and Supporting Elements The proposed addition is limited to 673 square feet and will be located on the front-left side of the existing clubhouse. Its modest size and location will have minimal impact on existing landscaping. Mature vegetation and the natural character of the bluff will be preserved so that they continue to soften views of the clubhouse. No landscaping changes are proposed on the water side of the building ; the existing vegetation and natural waterfront buffer will remain intact . If limited planting adjacent to the addition is disturbed during construction , it will be restored with native or Island-appropriate species compatible with the existing landscape. This approach is consistent with the Design Guide's emphasis on retain ing native vegetation , preserving the tree canopy, and mainta ining natural buffers along wetland and waterfront edges (Design Guide, pp. 18-22). Conclusion Together, these improvements preserve the clubhouse's established character and meet current functional needs through compatible form , human-scaled outdoor space, durable local mater ials, restrained colors, coordinated elevations , and landscape preservation consistent with the Town's Island Character princi pies. Page 2 Page 8 of 55 SPANISH WELLS CLUB ADDITION 1 BRAMS POINT ROAD SITE PLANS Page 9 of 55 DESIGN FOR SHEET DATE: REVISION: DESIGNED BY DRAWN BY PROJECT -BLDG 5 RIGGS Ln- STE 208 Bluffton SC 29910 Ph. 561.359.7213 COPYRIGHT 2024 FSL DESIGNER, THE USE OF THE DOCUMENT(S) AND THE DESIGN CONTENT WITHOUT WRITTEN PERMISSION FROM FSL DESIGNER IS PROHIBITED. FSL DESIGNER HAS NOT BEEN HIRED FOR CONSTRUCTION OR OBSERVATION MANAGEMENT DATE: 09.08.2025 09.18.2025 02.28.2026 03.04.2026 04.02.2026 05.12.2026 06.22.2026 FINAL SET INITIALS OWNERS _______ BUILDER________ FSL Designer Residential Designers - Architects 26-108 09-08-2025THE SPANISH WELLS GOLF CLUB HOUSE-REMODEL LOT# "BRAMS POINT ROAD -SPANISH WELLS PLANTATION " BEAUFORT COUNTY, HILTON HEAD SOUTH CAROLINA A0.0 1/8" = 1'-0"1 EXISTING SITE PLAN Page 10 of 55 DW SEPTIC OCRM CRITICAL LINE BAR EXISTING BUILDING DESIGN FOR SHEET DATE: REVISION: DESIGNED BY DRAWN BY PROJECT -BLDG 5 RIGGS Ln- STE 208 Bluffton SC 29910 Ph. 561.359.7213 COPYRIGHT 2024 FSL DESIGNER, THE USE OF THE DOCUMENT(S) AND THE DESIGN CONTENT WITHOUT WRITTEN PERMISSION FROM FSL DESIGNER IS PROHIBITED. FSL DESIGNER HAS NOT BEEN HIRED FOR CONSTRUCTION OR OBSERVATION MANAGEMENT DATE: 09.08.2025 09.18.2025 02.28.2026 03.04.2026 04.02.2026 05.12.2026 06.22.2026 FINAL SET INITIALS OWNERS _______ BUILDER________ FSL Designer Residential Designers - Architects F. SUAREZ LYNCH FES 26-108 09-08-2025THE SPANISH WELLS GOLF CLUB HOUSE-REMODEL LOT# "BRAMS POINT ROAD -SPANISH WELLS PLANTATION " BEAUFORT COUNTY, HILTON HEAD SOUTH CAROLINA A0.1 1/8" = 1'-0"1 FIRST LEVEL F.F. SITE PLAN Page 11 of 55 SPANISH WELLS CLUB ADDITION 1 BRAMS POINT ROAD ARCHITECTURE PLANS Page 12 of 55 GENERAL NOTES · NOTES TO GENERAL CONTRACTORS: THESE DRAWINGS HAVE BEEN PRODUCED UNDER A LIMITED SERVICE AGREEMENT BETWEEN THE OWNER AND FSL DESIGNER. THEY ARE TO BE USED IN CONJUNCTION WITH STRUCTURAL AND OTHER ENGINEERING REQUIREMENTS FOR A BUILDING PERMIT. · THESE DRAWINGS CANNOT STAND ALONE AS CONSTRUCTION DOCUMENTS · SEE STRUCTURAL ENGINEERING DOCUMENTS FOR STRUCTURAL CONNECTION TECHNIQUES, CALCULATIONS THAT ARE REQUIRE BY CODE. CODE COMPLIANCE INSTRUCTIONS FOR WALL AND ROOF CONSTRUCTION AND TIE DOWN REQUIREMENTS · SEPARATE MECHANICAL AND PLUMBING ENGINEERING DOCUMENTS MAY BE PROVIDED WHICH WOULD INDICATE REQUIRED SERVICE AND RISER DIAGRAMS, CALCULATIONS AND INSTALLATION SPECIFICATIONS BEYOND THE COMMERCIAL DESIGNERS BASIC LAYOUT AND SELECTIONS · SEPARATE CIVIL ENGINEERING DOCUMENTS MAY BE PROVIDED WHICH INDICATE ADDITIONAL SITE PREP PLANNING, AND DRAINAGE. · SELECTIONS NOT INCLUDED IN THESE DOCUMENTS WILL BE COORDINATED BY THE OWNER/OWNERS REPRESENTATIVE OR BUILDER.. · BY APPLYING FOR A BUILDING PERMIT AND /OF CONSTRUCTING THE PROJECT REPRESENTED HERE IN, THE OWNER AGREES TO LIMIT THE LIABILITY OF THE DESIGNER TO THE OWNER OF THE PROJECT FOR ALL AND ANY CLAIMS, LOSSES, DAMAGES OR ANY NATURE WHATSOEVER OR CLAIMS OF EXPENSE FOR ANY SUCH ITEMS TO THE DESIGNERS TOTAL COMPENSATION FOR SERVICES RENDERED HEREIN. · THESE DOCUMENTS ARE THE WORK INSTRUMENTS OF THE DESIGNER AND HAVE BEEN PREPARED SPECIFICALLY AND ARE NOT SUITABLE FOR USE ON OTHER PROJECTS OR IN OTHER LOCATIONS WITHOUT THE PARTICIPATION OF THE DESIGNER. REPRODUCTION IS STRICTLY PROHIBITED. THE DESIGNER SHALL BE DEEMED THE AUTHOR AND OWNER OF THESE DOCUMENTS AND SHALL RETAIN COMMON LOW STATUTORY AND OTHER RESERVED RIGHTS, INCLUDING THE COPY RIGHT. · THIS WRITTEN NOTICE BY THE SOUTH CAROLINA REGULATIONS TO THE PERMITTING AUTHORITY AND BUILDING OW NER THAT THE DESIGNER AT FSL DESIGNER HAVE NOT BEEN HIRED TO PROVIDE MINIMUM CONSTRUCTION ADMINISTRATION SERVICES ON THE FOLLOWING PROJECT. · FOR DIMENSIONS NOT SHOWN OR IN QUESTION, THE CONTRACTOR WILL REQUEST CLARIFICATION FROM THE DESIGNER BEFORE PROCEEDING. · CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS IN THE FIELD. ANY DISCREPANCIES WILL BE BROUGHT TO THE DESIGNER BEFORE PROCEEDING. · INFORMATION CONTAINED ON THESE DRAWINGS IS PROVIDED FOR THE CONVENIENCE OF THE GENERAL CONTRACTOR IN EXECUTING THE WORK . EVERY ATTEMPTS HAS BEEN MADE TO PROVIDE COMPLETE AND ACCURATE REPRESENTATIONS OF SUCH CONDITIONS. · WHEN ARCHITECTURAL DRAWINGS ARE IN CONFLICT WITH THE ENGINEERING DRAWINGS THE GENERAL CONTRACTOR SHALL REQUEST CLARIFICATIONS FROM THE DESIGNER BEFOREPROCEEDING. FSL DESIGNER HAS NOT BEEN HIRED FOR CONSTRUCTION MANAGEMENT OR OBSERVATION ON THIS PROJECT. DESIGN FOR SHEET DATE: REVISION: DESIGNED BY DRAWN BY PROJECT -BLDG 5 RIGGS Ln- STE 208 Bluffton SC 29910Ph. 561.359.7213 COPYRIGHT 2024 FSL DESIGNER, THE USE OF THE DOCUMENT(S) AND THE DESIGN CONTENT WITHOUT WRITTEN PERMISSION FROM FSL DESIGNER IS PROHIBITED. FSL DESIGNER HAS NOT BEEN HIRED FOR CONSTRUCTION OR OBSERVATION MANAGEMENT DATE: 09.08.2025 09.18.2025 02.28.2026 03.04.2026 04.02.2026 05.12.2026 06.22.2026 07.08.2026 FINAL SET INITIALS OWNERS _______ BUILDER________ FSL Designer Residential Designers - Architects F. SUAREZ LYNCH FES 26-108 09-08-2025THE SPANISH WELLS GOLF CLUB HOUSE-REMODEL LOT# "BRAMS POINT ROAD -SPANISH WELLS PLANTATION " BEAUFORT COUNTY, HILTON HEAD SOUTH CAROLINA CS SHEET LIST SHEET NUMBER SHEET NAME KL.1 KITCHEN LAYOUT CS COVER SHEET A0.0 ORIGINAL SITE PLAN A0.1 SITE PLAN A1.1 FOUNDATION PLAN A2.1 FIRST FLOOR PLAN A2.3 ROOF PLAN A3.1 EXTERIOR ELEVATIONS A3.2 EXTERIOR ELEVATIONS A3.3 3D EXTERIOR VIEWS A3.3B 3D EXTERIOR VIEWS 2 A3.3C 3D EXTERIOR VIEWS 3 A4.1 BUILDING SECTIONS A4.1B BUILDING SECTIONS A4.2 WALL SECTIONS A4.3 WALL SECTIONS A4.5 WALL SECTIONS A5.0 WINDOW & DOOR SCHEDULE A5.1 WINDOW DETAILS A6.1 DOOR DETAILS AD.1 ADA DETAILS S1.1 SAFETY PLAN E2.1 FIRST FLOOR ELECTRICAL PLAN S0.1 STRUCTURAL BUILDING CODE SUMMARY NAME OF PROJECT: ADDRESS: PROPOSED USE: OWNER/CONTACT: CODE ENFORCEMENT JURISDICATION: DESIGNER OF RECORD DESIGNER ELECTRICAL PLUMBING MECHANICAL STRUCTURAL CIVIL LANDSCAPER BUILDING DATA OCCUPANCY CLASSIFICATION MIXED OCCUPANCY CONSTRUCTION TYPE MIXED CONSTRUCTION SPRINKLERED FIRE DISTRICT BUILDING HEIGHT 22'-1" SPANISH WELLS GOLF CLUB HOUSE REMODEL LOT BRAMS POINT ROAD - SPANISH WELLS PLANTATION " BEAUFORT COUNTY, HILTON HEAD, SOUTH CAROLINA CLUB HOUSE XXXXXXXXXXXXXXXXX TOWN OF HILTON HEAD, BEAUFORT COUNTY, SC FSL DESIGNER __________ BLUFFTON, SC 29910 561-359-7213 __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ NO SEPARATION I-A I-B II-B III-A III-B IV V-A V-B NO TYPE NO NO BUILDING STORIES 1 A II OCCUPANT LOAD (IBC 1004.5) OCCUPANCY A-2 =174 PERSONS __________ __________ __________ __________ __________ __________ EXIT TABLE (IBC 1003.3.3) MORE 50 PERSONS - 2 EXITS IBC TRAVEL DISTANCE LESS 200 LFT - MEET REQUIREMENTS LESS 5000 SQFT - LESS 300 PERSONS Page 13 of 55 FOUNDATION NOTES: 1 4" THICK 3,000 PSI CONCRETE SLAB REINF. W/ 6X6 #10/#10 W.W.M. ON 6 MIL POLYETHYLENE VAPOR BARRIER ON CLEAN, DRY, COMPACTED, TERMITE TREATED EARTH FILL. 2 8" WIDE X 12" DEEP, 3,000 PSI MONOLITHIC CONCRETE FOOTING W/ #4 BAR CONT. OVERLAP ENDS 40X DIA. MIN., EXTEND 6X6 #10/#10 W.W.M. FROM CONC. SLAB INTO FOOTING. 3 4" THICK, 3,000 PSI CONCRETE SLAB REINF. W/ 6X6 #10/#10 W.W.M. ON CLEAN, DRY, TREATED, COMPACTED EARTH FILL. 4 16" X 16" CMU PIER ON 3' X 3' X 18" CONCRETE FOOTING WITH (3) 5/8" REBAR EACH WAY. (2) 5/8" VERTICAL RODS. FILL PIER W/ 3000 PSI GROUT. 5 16" X 16" CMU PIER ON 3' X 3' X 18" CONCRETE FOOTING WITH (3) 5/8" REBAR EACH WAY. (2) 5/8" VERTICAL RODS. FILL PIER W/ 3000 PSI GROUT. 6 8" X 1 6" CMU WALL W/5/8" VERTI CAL REBAR IN EACH CORNER @32"O.C.. FILL CMU WALL WITH CONCRETE GOUT 2500 PS FILL WITH TREATED COMPACTED SOIL. 32" WIDE X 16" DEEP CONCRETE FOOTING W ITH (3) 5/8" REBAR OVERLAP 40 X DIA. 7 DEPRESS SLAB AT SLIDING DOOR 1-3/4" TO ACCEPT DOOR SILL. SEE FLOOR PLAN FOR LOCATION OF SLIDING DOORS. 8 PROVIDE SOLID MASONRY STUCCO TRIM, SURROUND & PILASTERS NO QUIK-R, B-BOARD SHALL BE USED ON RESIDENCE. 9 ANY WOOD, PLYWOOD OR FIBROUS MATERIAL INSTALLED AGAINST A MASONRY SURFACE SHALL BE OF A PRESSURE TREATED NATURE. ANY MATERIAL INSTALLED BELOW FLOOD SHALL BE NON-SOLUBLE. NO EXCEPTIONS. 10 16" W IDE X 36" +/- DEEP 3,000 PSI MONOLITHIC CONC. FOOTING W/ #4 BAR CONT. OVERLAP ENDS 40X DIA. MIN., EXTEND 6X6 #10/#10 W.W.M. FROM CONCRETE SLAB INTO FOOTING 11 NOT USED. 12 16" W IDE X 20" +/- DEEP, 3,000 PSI MONOLITHIC CONCRETE FOOTING W/ #4 BAR CONT. OVERLAP ENDS 40X DIA. MIN., EXTEND 6X6 #10/#10 W.W.M. FROM CONCRETE SLAB INTO FOOTING. 13 24" W IDE X 20" DEEP, 3,000 PSI MONOLITHIC CONCRETE FOOTING W/ #4 BAR CONT. OVERLAP ENDS 40X DIA. MIN., EXTEND 6X6 #10/#10 W.W.M. FROM CONCRETE SLAB INTO FOOTING. VERIFY FOUNDATION DETAILS WITH STRUCTURAL SHEETS. STRUCTURAL OVERRIDE THESE SHEETS 12' - 3 11/16" 8' - 2 9/16" 21' - 6 1/2" 11' - 10 1/2" 9' - 2 3/4" 9' - 5 3/4" EXISTING FOUNDATION 10' - 10 1/16" 12' - 5 1/16" 8X8 PT WOOD POST 8X8 PT WOOD POST 8X8 PT WOOD POST 8X8 PT WOOD POST 8X8 PT WOOD POST 16X16X12 CONCRETE PIER BY ENGINEER 1' - 4" 25' - 0 3/4" 8' - 9 1/2" 8' - 9 1/2" 8' - 9 1/2" 22' - 3 1/16"8" 11' - 2 5/16" 6' - 4" 9' - 0 7/8" 6' - 6 5/8" 4' - 0" 6' - 6 5/8" 2' - 6" GRADE BEAM 11' - 1 13/16" 11' - 1 1/4"8" 16X16X12 CONCRETE PIER BY ENGINEER 16X16X12 CONCRETE PIER BY ENGINEER 8X8 PT WOOD POST 1 3 3 3 3 2 3 10 10 10 3 8" PROPOSED FOUNDATION ALL STRUCTURE BY ENGINEER 72' - 7 13/16" -2" 1ST FF 1/8" SLOPE TO DRAIN -2" 1ST FF 1/8" SLOPE TO DRAIN FP 13.67 NAVD88 1ST FL 13.8 NAVD88 DESIGN FOR SHEET DATE: REVISION: DESIGNED BY DRAWN BY PROJECT -BLDG 5 RIGGS Ln- STE 208 Bluffton SC 29910 Ph. 561.359.7213 COPYRIGHT 2024 FSL DESIGNER, THE USE OF THE DOCUMENT(S) AND THE DESIGN CONTENT WITHOUT WRITTEN PERMISSION FROM FSL DESIGNER IS PROHIBITED. FSL DESIGNER HAS NOT BEEN HIRED FOR CONSTRUCTION OR OBSERVATION MANAGEMENT DATE: 09.08.2025 09.18.2025 02.28.2026 03.04.2026 04.02.2026 05.12.2026 06.22.2026 FINAL SET INITIALS OWNERS _______ BUILDER________ FSL Designer Residential Designers - Architects F. SUAREZ LYNCH FES 26-108 09-08-2025THE SPANISH WELLS GOLF CLUB HOUSE-REMODEL LOT# "BRAMS POINT ROAD -SPANISH WELLS PLANTATION " BEAUFORT COUNTY, HILTON HEAD SOUTH CAROLINA A1.11/4" = 1'-0"1 FOUNDATION PLAN Page 14 of 55 DW GENERAL NOTES: 1. ALL WORK SHALL BE IN ACCORDANCE WITH THE CURRENT EDITION OF THE 2021 I.B.C. (INTERNATIONAL BUILDING CODE), WITH SOUTH CAROLINA AMENDMENTS, IECC 2009 ENERGY CODE AND ICC 600 HIGH WIND CONSTRUCTION 2. PROVIDE HURRICANE CLIPS AT ALL RAFTERS AND JOISTS. AT ALL EXTERIOR DECK FLOOR JOISTS PROVIDE GALVANIZED HURRICANE CLIPS. 3. ALL PLUMBING WORK SHALL CONFORM TO LOCAL, STATE, AND FEDERAL CODES INCLUDING THE CURRENT EDITION OF THE STANDARD PLUMBING CODE. USE WATER EFFICIENT FIXTURES AND LOCATE HOT WATER HEATERS CLOSE TO LARGE USAGE FIXTURES TO MINIMIZE LOADING. 4. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION WITH LOCAL OR PRIVATE UTILITY COMPANIES OR AGENCIES FOR RELOCATION OF, OR CONNECTION TO EXISTING UTILITIES. 5. THE TOP HEAD OF EXTERIOR DOORS AND WINDOWS TO BE AT THE SAME HEIGHT ABOVE THE FINISH FLOOR U.N.O. 6. ALL EXTERIOR WALLS ARE 2x6, U.N.O. 7. ALL INTERIOR WALLS ARE 2x4, EXCEPT WHERE NOTED. 8. ANY MATERIAL IN CONTACT WITH CONCRETE SHALL BE PRESSURE TREATED. 9. ALL MATERIAL BELOW FLOOD SHALL BE NON-SOLUBLE MATERIAL. 10. CONTRACTOR AND SUBS SHALL REVIEW PLANS PRIOR TO CONSTRUCTION. CONTACT DESIGNER IF QUESTIONS ARISE BEFORE BUILDING. 11. PROVIDE INSULATION BEHIND ALL TUBS. INSTALL WITH NO VOIDS. 12. 5/8" TYP "WR & X" AT CLG OF GARAGE 1ST FL 13.8 NAVD88 FP 13.67 NAVD88 RP 13.8 NAVD88 19' - 8" 2 A4.1B PIZZA OVENFRYERGRILL/OVEN SPACE FOR APPLIANCES 3' - 1"3' - 1" VAULTED 12' - 0" SERVICE YARD 1 A4.1 REF. CHAMBER #1 REF. CHAMBER #2 LIFT DIRTY DISHES CLEAN DISHES CLEAN DISHES DELIVER ZONE PREPARATION ZONE SALON'S CONNECTION STORAGE ACCESS TV ABOVE OPENNING EXTERIOR BAR REAR PORCH FRONT PORCH 5' - 0" 6' - 8" 3' - 0" ADA TOILET 5' - 4" 6' - 4" 3' - 0" 1' - 2" 1' - 2" ADA TOILET 2 A4.1 3' - 0" 12' - 3 11/16" 8' - 2 9/16" 21' - 6 1/2" 11' - 10 1/2" 9' - 2 3/4" 9' - 5 3/4" 10' - 10 1/16" 7' - 2 3/16" 1' - 0" 11' - 4 1/4" 4' - 3 1/4" 12' - 1 1/4" 12' - 8"7' - 0 1/2"4' - 6 9/16" 18' - 10 3/4" 8' - 10" 8 1/2" 8' - 9 1/2" 8' - 9 1/2" 8' - 9 1/2" 7 3/4" 5' - 0 1/8" 8' - 10 1/4" 8' - 10 1/4" 5' - 0 1/8" 27' - 8 3/4" 18' - 3"20' - 2 1/2" 13' - 5 15/16"10' - 10 9/16" 11' - 3 1/4" 4' - 10 1/2" 14' - 10 1/4" 9' - 4" 11' - 0" 29' - 4" 3' - 4 1/2" 4' - 2" 10' - 10 9/16" 13' - 5 15/16" 61' - 3" 31' - 0" 10 3/4" 10' - 1 1/2" 9' - 3" 10' - 1" 7 3/4" 5' - 7 3/4" 19' - 8 1/2" 5' - 7 3/4" 13' - 5 15/16"10' - 9 1/16" 22' - 1 1/4" 24' - 3 1/16" 3' - 0"3' - 0" 4' - 10 1/4" 3' - 7" 3' - 1 5/8" 15' - 10 1/4" LVL'S FOR STRUCTURAL WALL BY ENGINEER LVL'S FOR STRUCTURAL WALL BY ENGINEER 10' - 5"1' - 5 1/2"15' - 10 1/2"1' - 7" STUCCO FINISH FIRE PLACE WALLS 12' - 5 1/16" 74' - 10 5/8" 1 6 2 15 14 13 12 11 18 10 9 17 16 8 7 19 20 MAIN SALON WOOD BAR TILE DAILY SALON WOOD STORAGE II TILE ELECTRICAL ROOM TILE HALLWAY TILE STORAGE TILE IN - OUT HALL TILE CLEANING ZONE TILE KITCHEN TILE 22' - 1 1/4" 2' - 6" 6' - 6 5/8" 4' - 0" 6' - 6 5/8" 2' - 6" 1' - 2 1/4" 1' - 2 1/4" BBBB BBBB 2' - 3 7/8" 2' - 9 1/2" 5' - 11 1/4" 5' - 11 1/4" 2' - 9 1/2" 2' - 3 7/8" 5' - 0 1/2" 5' - 0 1/2" 1' - 2 1/4" 1' - 2 1/4" 2' - 3 1/4" 2' - 11 1/4" 3' - 9 3/4" 3' - 5 1/2" 11' - 2 5/16" 6' - 4" 9' - 0 7/8" 38' - 7" 1ST FL 13.8 NAVD88 1 A4.1B 3 A4.1B 5' - 7 3/4" 2' - 0"3' - 5" 3' - 0" HOOD 9' - 0" 4' - 2" 2-150 AMP PANELS 2' - 6 1/2" 7' - 1" PLANTERS PLANTERS VAULTED VAULTED LADIES RESTROOM TILE MEN RESTROOM TILE 20' - 0 1/2" SHOP WOOD OFFICE WOOD 52 2A2B 1 A4.2 2 A4.2 1 A4.3 AD D 3 BUFFET TABLES BUFFET TABLES 4 B B B 2' - 8" 2' - 9 1/2" 2' - 9 1/2" 26' - 8" 26' - 4" 2 A4.3 TYPE X FIRE RATED DRYW ALL TYPE X FIRE RATED DRYW ALL TYPE X FIRE RATED DRYW ALL TYPE X FIRE RATED DRYW ALL WALLS / CEILING TYPE X FIRE RATED DRYW ALL TYPE X FIRE RATED DRYW ALL 5 EXIST 1ST FLOOR HEATED: 3,836 SF ADD COVERED PORCHES: 1.000 SF AREA CALCULATIONS: SERVICE YARDS: 120 SF EXIST COVERED PORCHES: 0,152 SF TOTAL HEATED: 4,509SF ADD 1ST FLOOR HEATED: 0,673 SF B B B B B 13' - 9 7/16" 8' - 8 5/8" 2' - 9 1/2" 13' - 4 1/2" 16' - 7 7/16" 9' - 10 1/2" 7' - 5" 2' - 9 1/2" 2' - 9 1/2" 2' - 7 1/2" DESIGN FOR SHEET DATE: REVISION: DESIGNED BY DRAWN BY PROJECT -BLDG 5 RIGGS Ln- STE 208 Bluffton SC 29910 Ph. 561.359.7213 COPYRIGHT 2024 FSL DESIGNER, THE USE OF THE DOCUMENT(S) AND THE DESIGN CONTENT WITHOUT WRITTEN PERMISSION FROM FSL DESIGNER IS PROHIBITED. FSL DESIGNER HAS NOT BEEN HIRED FOR CONSTRUCTION OR OBSERVATION MANAGEMENT DATE: 09.08.2025 09.18.2025 02.28.2026 03.04.2026 04.02.2026 05.12.2026 06.22.2026 FINAL SET INITIALS OWNERS _______ BUILDER________ FSL Designer Residential Designers - Architects F. SUAREZ LYNCH FES 26-108 09-08-2025THE SPANISH WELLS GOLF CLUB HOUSE-REMODEL LOT# "BRAMS POINT ROAD -SPANISH WELLS PLANTATION " BEAUFORT COUNTY, HILTON HEAD SOUTH CAROLINA A2.11/4" = 1'-0"1 FIRST LEVEL F.F. Page 15 of 55 6" / 12" 6" / 12" 6" / 12" 12" / 12"12" / 12"12" / 12"12" / 12" 6" / 12" 6" / 12" 6" / 12" 6" / 12" 12" / 12"12" / 12" 2" / 12" 6" / 12" 2" / 12" 10" / 12" 10" / 12" 10" / 12" 10" / 12" 6" / 12" 6" / 12" 2X8 RAFTER @ 16 O.C 2X8 RAFTER @ 16 O.C 2X8 RAFTER @ 16 O.C 2X8 RAFTER @ 16 O.C 2X8 RAFTER @ 16 O.C 2X8 RAFTER @ 16 O.C 2X8 RAFTER @ 16 O.C 2X8 RAFTER @ 16 O.C 2X8 RAFTER @ 16 O.C 2X8 RAFTER @ 16 O.C METAL ROOF METAL ROOFMETAL ROOF METAL ROOF METAL ROOFMETAL ROOF METAL ROOF METAL ROOF METAL ROOF METAL ROOF METAL ROOF 6" / 12" METAL ROOFMETAL ROOF METAL ROOFMETAL ROOF METAL ROOFMETAL ROOF METAL ROOF EXISTING ROOF STRUCTURE EXISTING ROOF STRUCTURE EXISTING ROOF STRUCTURE EXISTING ROOF STRUCTURE EXISTING ROOF STRUCTURE EXISTING ROOF STRUCTURE EXISTING ROOF STRUCTURE EXISTING ROOF STRUCTURE EXISTING ROOF STRUCTURE EXISTING ROOF STRUCTURE EXISTING ROOF STRUCTURE EXTEND EXISTING ROOF TO CHIMNEY RIDGERIDGE RIDGE RIDGE RIDGE VA LLEY VA LLEY VALLEY VALLEY VALLEY VALLEY VALLEY VALLEY VALLEY VALLEY VALLEY ROOF JOIN ROOF JOIN RIDGE VALLEY HIP HIP HIP HIP HIP HIP HIP HIP CHIMNEY FLASHING SLOPESLOPE SLOPE SLOPE SLOPE SLOPE SLOPE SLOPE SLOPE SLOPE SLOPE SLOPE SLOPE SLOPE SLOPE SLOPE SLOPE SLOPE SLOPE SLOPE SLOPESLOPE METAL ROOFMETAL ROOF EXISTING ROOF STRUCTURE ROOF JOINROOF JOIN NEW ROOF NEW ROOF NEW ROOF NEW ROOF NEW ROOF CHIMNEY 2X8 RAFTER @ 16 O.C 3" / 12" SLOPE SLOPE METAL ROOFMETAL ROOF 2X8 RAFTER @ 16 O.C METAL ROOF SLOPE 3" / 12" DESIGN FOR SHEET DATE: REVISION: DESIGNED BY DRAWN BY PROJECT -BLDG 5 RIGGS Ln- STE 208 Bluffton SC 29910 Ph. 561.359.7213 COPYRIGHT 2024 FSL DESIGNER, THE USE OF THE DOCUMENT(S) AND THE DESIGN CONTENT WITHOUT WRITTEN PERMISSION FROM FSL DESIGNER IS PROHIBITED. FSL DESIGNER HAS NOT BEEN HIRED FOR CONSTRUCTION OR OBSERVATION MANAGEMENT DATE: 09.08.2025 09.18.2025 02.28.2026 03.04.2026 04.02.2026 05.12.2026 06.22.2026 FINAL SET INITIALS OWNERS _______ BUILDER________ FSL Designer Residential Designers - Architects F. SUAREZ LYNCH FES 26-108 09-08-2025THE SPANISH WELLS GOLF CLUB HOUSE-REMODEL LOT# "BRAMS POINT ROAD -SPANISH WELLS PLANTATION " BEAUFORT COUNTY, HILTON HEAD SOUTH CAROLINA A2.3 NOTE: ALL RIDGES ARE TO BE CONTINUOUS MEMBERS WHERE POSSIBLE USING AVAILABLE STANDARD LUMBER SIZES 1/4" = 1'-0"1 ROOF PLAN Page 16 of 55 FLASHING NOTES: 1. PROVIDE ISOLATION MATERIAL BETWEEN DISSIMILAR METALS TO PREVENT GALVANIC REACTION. 2. PROVIDE PREFINISHED CONCEALED METAL FLASHING AT ALL W INDOW S AND DOORS. 3. PROVIDE PREFINISHED OR CONCEALED METAL FLASHING AT ROOF TO WALL APPLICATIONS. IF WALL IS RUNNING AT AN ANGLE, PROVIDE STEP FLASHING. INSTALL PER BUILDING CODE. HARDIE HORIZONTAL PLANK SIDING FIBERGLASS ARCHITECTURAL SHINGLES TABBY STUCCO 5V METAL ROOF LEGEND ROOF WALL FIRST LEVEL F.F. FIRST LEVEL F.F. FIRST LEVEL PLATE HT. FIRST LEVEL PLATE HT. APPROXIMATE LINE OF FINISH GRADE 8' - 0" 1ST FL 13.8 NAVD881ST FL 13.8 NAVD88 OLD SAVANNAH BRICK EXISTING STRUCTURE NEW 5V METAL ROOF HORIZONTAL HARDIE PLANK EXISTING STRUCTURE NEW 5V METAL ROOF 2' - 5 3/4" PT WOOD BRACKET NEW 5V METAL ROOFNEW 5V METAL ROOF 8X8 PT WOOD POST 1X8 + 1X4 FASCIA CONT. HORIZONTAL HARDIE PLANK C C C C CB B EXTEND EXISTING ROOF 22' - 1 11/16" FIRST LEVEL F.F. FIRST LEVEL F.F. FIRST LEVEL PLATE HT. FIRST LEVEL PLATE HT. 1ST FL 13.8 NAVD881ST FL 13.8 NAVD88 OLD SAVANNAH BRICK EXISTING STRUCTURE NEW 5V METAL ROOF EXISTING STRUCTURE NEW 5V METAL ROOF 8X8 PT WOOD POST 1X8 + 1X4 FASCIA CONT. HORIZONTAL HARDIE PLANK NEW 5V METAL ROOF NEW 5V METAL ROOF 8X8 PT WOOD POST OLD SAVANNAH BRICK EXISTING STRUCTURE NEW 5V METAL ROOF C C C C C DESIGN FOR SHEET DATE: REVISION: DESIGNED BY DRAWN BY PROJECT -BLDG 5 RIGGS Ln- STE 208 Bluffton SC 29910 Ph. 561.359.7213 COPYRIGHT 2024 FSL DESIGNER, THE USE OF THE DOCUMENT(S) AND THE DESIGN CONTENT WITHOUT WRITTEN PERMISSION FROM FSL DESIGNER IS PROHIBITED. FSL DESIGNER HAS NOT BEEN HIRED FOR CONSTRUCTION OR OBSERVATION MANAGEMENT DATE: 09.08.2025 09.18.2025 02.28.2026 03.04.2026 04.02.2026 05.12.2026 06.22.2026 FINAL SET INITIALS OWNERS _______ BUILDER________ FSL Designer Residential Designers - Architects F. SUAREZ LYNCH FES 26-108 09-08-2025THE SPANISH WELLS GOLF CLUB HOUSE-REMODEL LOT# "BRAMS POINT ROAD -SPANISH WELLS PLANTATION " BEAUFORT COUNTY, HILTON HEAD SOUTH CAROLINA A3.1 1/4" = 1'-0"1 FRONT ELEVATION 1/4" = 1'-0"2 REAR ELEVATION Page 17 of 55 FLASHING NOTES: 1. PROVIDE ISOLATION MATERIAL BETWEEN DISSIMILAR METALS TO PREVENT GALVANIC REACTION. 2. PROVIDE PREFINISHED CONCEALED METAL FLASHING AT ALL W INDOW S AND DOORS. 3. PROVIDE PREFINISHED OR CONCEALED METAL FLASHING AT ROOF TO WALL APPLICATIONS. IF WALL IS RUNNING AT AN ANGLE, PROVIDE STEP FLASHING. INSTALL PER BUILDING CODE. FIRST LEVEL F.F. FIRST LEVEL F.F. FIRST LEVEL PLATE HT. FIRST LEVEL PLATE HT. 1ST FL 13.8 NAVD881ST FL 13.8 NAVD88 8' - 0" OLD SAVANNAH BRICK HORIZONTAL HARDIE PLANK 8X8 PT WOOD POST 1X8 + 1X4 FASCIA CONT. NEW 5V METAL ROOF 8X8 PT WOOD POST 1X8 + 1X4 FASCIA CONT. EXISTING STRUCTURE NEW 5V METAL ROOF EXISTING STRUCTURE NEW 5V METAL ROOF HORIZONTAL HARDIE PLANK FIRST LEVEL F.F. FIRST LEVEL F.F. FIRST LEVEL PLATE HT. FIRST LEVEL PLATE HT. APPROXIMATE LINE OF FINISH GRADE 1ST FL 13.8 NAVD881ST FL 13.8 NAVD88 2' - 5 3/4" OLD SAVANNAH BRICK HORIZONTAL HARDIE PLANK PT WOOD BRACKET 8X8 PT WOOD POST 1X8 + 1X4 FASCIA CONT. NEW 5V METAL ROOFNEW 5V METAL ROOF 8X8 PT WOOD POST 1X8 + 1X4 FASCIA CONT. EXISTING CHIMNEY EXISTING STRUCTURE NEW 5V METAL ROOF DESIGN FOR SHEET DATE: REVISION: DESIGNED BY DRAWN BY PROJECT -BLDG 5 RIGGS Ln- STE 208 Bluffton SC 29910 Ph. 561.359.7213 COPYRIGHT 2024 FSL DESIGNER, THE USE OF THE DOCUMENT(S) AND THE DESIGN CONTENT WITHOUT WRITTEN PERMISSION FROM FSL DESIGNER IS PROHIBITED. FSL DESIGNER HAS NOT BEEN HIRED FOR CONSTRUCTION OR OBSERVATION MANAGEMENT DATE: 09.08.2025 09.18.2025 02.28.2026 03.04.2026 04.02.2026 05.12.2026 06.22.2026 FINAL SET INITIALS OWNERS _______ BUILDER________ FSL Designer Residential Designers - Architects F. SUAREZ LYNCH FES 26-108 09-08-2025THE SPANISH WELLS GOLF CLUB HOUSE-REMODEL LOT# "BRAMS POINT ROAD -SPANISH WELLS PLANTATION " BEAUFORT COUNTY, HILTON HEAD SOUTH CAROLINA A3.2 1/4" = 1'-0"1 RIGHT ELEVATION 1/4" = 1'-0"2 LEFT ELEVATION Page 18 of 55 DESIGN FOR SHEET DATE: REVISION: DESIGNED BY DRAWN BY PROJECT -BLDG 5 RIGGS Ln- STE 208 Bluffton SC 29910 Ph. 561.359.7213 COPYRIGHT 2024 FSL DESIGNER, THE USE OF THE DOCUMENT(S) AND THE DESIGN CONTENT WITHOUT WRITTEN PERMISSION FROM FSL DESIGNER IS PROHIBITED. FSL DESIGNER HAS NOT BEEN HIRED FOR CONSTRUCTION OR OBSERVATION MANAGEMENT DATE: 09.08.2025 09.18.2025 02.28.2026 03.04.2026 04.02.2026 05.12.2026 06.22.2026 FINAL SET INITIALS OWNERS _______ BUILDER________ FSL Designer Residential Designers - Architects F. SUAREZ LYNCH FES 26-108 09-08-2025THE SPANISH WELLS GOLF CLUB HOUSE-REMODEL LOT# "BRAMS POINT ROAD -SPANISH WELLS PLANTATION " BEAUFORT COUNTY, HILTON HEAD SOUTH CAROLINA A3.3 2 3D REAR LEFT VIEW 3 3D REAR RIGHT VIEW Page 19 of 55 DESIGN FOR SHEET DATE: REVISION: DESIGNED BY DRAWN BY PROJECT -BLDG 5 RIGGS Ln- STE 208 Bluffton SC 29910 Ph. 561.359.7213 COPYRIGHT 2024 FSL DESIGNER, THE USE OF THE DOCUMENT(S) AND THE DESIGN CONTENT WITHOUT WRITTEN PERMISSION FROM FSL DESIGNER IS PROHIBITED. FSL DESIGNER HAS NOT BEEN HIRED FOR CONSTRUCTION OR OBSERVATION MANAGEMENT DATE: 09.08.2025 09.18.2025 02.28.2026 03.04.2026 04.02.2026 05.12.2026 06.22.2026 FINAL SET INITIALS OWNERS _______ BUILDER________ FSL Designer Residential Designers - Architects F. SUAREZ LYNCH FES 26-108 09-08-2025THE SPANISH WELLS GOLF CLUB HOUSE-REMODEL LOT# "BRAMS POINT ROAD -SPANISH WELLS PLANTATION " BEAUFORT COUNTY, HILTON HEAD SOUTH CAROLINA A3.3B 1 3D FRONT LEFT VIEW 2 3D FRONT RIGHT VIEW Page 20 of 55 DESIGN FOR SHEET DATE: REVISION: DESIGNED BY DRAWN BY PROJECT -BLDG 5 RIGGS Ln- STE 208 Bluffton SC 29910 Ph. 561.359.7213 COPYRIGHT 2024 FSL DESIGNER, THE USE OF THE DOCUMENT(S) AND THE DESIGN CONTENT WITHOUT WRITTEN PERMISSION FROM FSL DESIGNER IS PROHIBITED. FSL DESIGNER HAS NOT BEEN HIRED FOR CONSTRUCTION OR OBSERVATION MANAGEMENT DATE: 09.08.2025 09.18.2025 02.28.2026 03.04.2026 04.02.2026 05.12.2026 06.22.2026 FINAL SET INITIALS OWNERS _______ BUILDER________ FSL Designer Residential Designers - Architects F. SUAREZ LYNCH FES 26-108 09-08-2025THE SPANISH WELLS GOLF CLUB HOUSE-REMODEL LOT# "BRAMS POINT ROAD -SPANISH WELLS PLANTATION " BEAUFORT COUNTY, HILTON HEAD SOUTH CAROLINA A3.3C 1 Vista 3D 1 Page 21 of 55 FIRST LEVEL F.F. SECOND FLOOR F.F. FIRST LEVEL PLATE HT. SECOND FLOOR PLATE HT. 8' - 0" LVL'S FOR STRUCTURAL WALL BY ENGINEER LVL'S FOR STRUCTURAL WALL BY ENGINEER MAIN SALON FRONT PORCHREAR PORCH 22' - 1 11/16" 21' - 2 11/16" 14' - 4 3/8" 11' - 0" FIRST LEVEL F.F. FIRST LEVEL PLATE HT. 3' - 0" 8' - 0" 8' - 6" STORAGE II STORAGE KITCHENREAR PORCH DAILY SALON ATTIC TYPE X FIRE RATED DRYW ALL WALLS/CEILING DESIGN FOR SHEET DATE: REVISION: DESIGNED BY DRAWN BY PROJECT -BLDG 5 RIGGS Ln- STE 208 Bluffton SC 29910 Ph. 561.359.7213 COPYRIGHT 2024 FSL DESIGNER, THE USE OF THE DOCUMENT(S) AND THE DESIGN CONTENT WITHOUT WRITTEN PERMISSION FROM FSL DESIGNER IS PROHIBITED. FSL DESIGNER HAS NOT BEEN HIRED FOR CONSTRUCTION OR OBSERVATION MANAGEMENT DATE: 09.08.2025 09.18.2025 02.28.2026 03.04.2026 04.02.2026 05.12.2026 06.22.2026 FINAL SET INITIALS OWNERS _______ BUILDER________ FSL Designer Residential Designers - Architects F. SUAREZ LYNCH FES 26-108 09-08-2025THE SPANISH WELLS GOLF CLUB HOUSE-REMODEL LOT# "BRAMS POINT ROAD -SPANISH WELLS PLANTATION " BEAUFORT COUNTY, HILTON HEAD SOUTH CAROLINA A4.1 1/4" = 1'-0"1 Section 5 1/4" = 1'-0"2 Section 6 Page 22 of 55 FIRST LEVEL F.F. FIRST LEVEL PLATE HT. MAIN SALON BATH HALL SHOP FIRST LEVEL F.F. FIRST LEVEL PLATE HT. SHOP OFFICE FIRST LEVEL F.F. FIRST LEVEL PLATE HT. ATTIC KITCHEN TYPE X FIRE RATED DRYW ALL WALLS/CEILING DESIGN FOR SHEET DATE: REVISION: DESIGNED BY DRAWN BY PROJECT -BLDG 5 RIGGS Ln- STE 208 Bluffton SC 29910 Ph. 561.359.7213 COPYRIGHT 2024 FSL DESIGNER, THE USE OF THE DOCUMENT(S) AND THE DESIGN CONTENT WITHOUT WRITTEN PERMISSION FROM FSL DESIGNER IS PROHIBITED. FSL DESIGNER HAS NOT BEEN HIRED FOR CONSTRUCTION OR OBSERVATION MANAGEMENT DATE: 09.08.2025 09.18.2025 02.28.2026 03.04.2026 04.02.2026 05.12.2026 06.22.2026 FINAL SET INITIALS OWNERS _______ BUILDER________ FSL Designer Residential Designers - Architects F. SUAREZ LYNCH FES 26-108 09-08-2025THE SPANISH WELLS GOLF CLUB HOUSE-REMODEL LOT# "BRAMS POINT ROAD -SPANISH WELLS PLANTATION " BEAUFORT COUNTY, HILTON HEAD SOUTH CAROLINA A4.1B 1/4" = 1'-0"1 Section 7 1/4" = 1'-0"2 Section 0 1/4" = 1'-0"3 Section 8 Page 23 of 55 FIRST LEVEL F.F. FIRST LEVEL PLATE HT. 4' - 0" RFT BRNG HEIGHT 9' - 5" 8' - 0" SIMPSON HOLDDOWN CORNERS AS REQUIERED LOW PROFILE GALV. PREFINISHED METAL DRIP EDGE 1 X 8 S4S FASCIA CONT. 1 X 4 S4S TRIM + BLOCKING HARDIE SOFFIT PANEL 2X8 SUB FASCIA 1 X 4 S4S TRIM + BLOCKING R19 OPEN CELL FOAM @ RAFTER DECK SIMPSON GALV. METAL HOLD-DOWN W/ 5/8" ANCHOR BOLT. LOCATE HOLD-DOWN AS PER PLAN LOCATION. ATTACH IN STRICT COMPLIANCE W/ MANUFACTURER & ENGINEERS SPECIFICATIONS. 5V METAL ROOF 1/2" GYP. BOARD 2X8 CJ OR AS NOTED @ 16" O.C. DECKING SCREWED AND GLUED ADVANTECH PLYWOOD ALL STRAPPING DESIGN BY ENGINEER CONTRACTOR TO HAVE FRAMING SYSTEM DESIGNED BY SUPPLIER AND REVIEWED BY STRUCTURAL ENGINEER PRIOR TO ORDER AND INSTALLATION. 2X6 PURLINS-CUT BETWEEN WOOD STUDS 48" O.C. FOR PLYWOOD SHEATHING REQUIREMENTS. R-19 INSULATION BETWEEN 2 X6 WD. STUDS @ 16" O.C. 1/2" OSB PLYWOOD SHEATHING W/ DUPONT "TYVEK WRAP" ON ENTIRE EXTERIOR, NAIL SHEATHING IN ACCORDANCE W/ IBC 2021 & ICC-600 HIGH WIND STANDARDS. FIRST SHEET TO BE P.T. 1X8 HARDIE PLANK HORIZONTAL SIDING W/6.25" EXPOSURE OLD SAVANNAH BRICK 2' - 5 3/4" NOTE: ALL STRUCTURAL MEMBERS & ANY EXTERIOR MATERIAL SHALL MEET OR EXCEED A 150 M.P.H. (MIN.) WIND LOAD & MEET OR EXCEED ALL BUILDIING CODES INCLUDING IBC 2021 W/SOUTH CAROLINA AMENDMENTS & 2009 IECC ENERGY CODES. 16" X 36"+/- (HT. VARIES CONCRETE STEM WALL W/4" CONCRETE MONOLITHIC SLAB OVER BUILT UP COMPACTED SOIL. INSTALL #5 VERTICAL BAR @ 18" O.C. MAX., 3000 PSI CONCRETE SLAB W/#5 REBAR CONT. OVERLAP ENDS 40 X DIA. MIN. EXTEND 6 X 6 X #10/#10 W.W.W. FROM CONCRETE SLAB INTO FOOTING 2X6 WD. P.T. BOTTOM PLATE CONT. 4" THICK, 3000 P.S.I. CONCRETE SLAB REINF. W/ 6x6 #10/#10 W.W.M. OR FIBERGLASS ON CLEAN, DRY, TREATED, TERMITE COMPACTED EARTH FILL SIMPSON GALV. METAL HOLD-DOWN W/ 5/8" ANCHOR BOLT. LOCATE HOLD-DOWN AS PER PLAN LOCATION. ATTACH IN STRICT COMPLIANCE W/ MANUFACTURER AND ENGINEERS SPECIFICATIONS. SILL SEAL FIRST LEVEL F.F. FIRST LEVEL PLATE HT. 1' - 8" RFT BRNG HEIGHT 11' - 8 7/16" 8' - 0" 8' - 5" COLUMN HEIGHT 8' - 4 1/4" ALL STRAPPING DESIGN BY ENGINEER CONTRACTOR TO HAVE FRAMING SYSTEM DESIGNED BY SUPPLIER AND REVIEWED BY STRUCTURAL ENGINEER PRIOR TO ORDER AND INSTALLATION. NOTE: ALL STRUCTURAL MEMBERS & ANY EXTERIOR MATERIAL SHALL MEET OR EXCEED A 150 M.P.H. (MIN.) WIND LOAD & MEET OR EXCEED ALL BUILDIING CODES INCLUDING IBC 2021 W/SOUTH CAROLINA AMENDMENTS & 2009 IECC ENERGY CODES. 1/2" GYP. BOARD 2X8 CJ OR AS NOTED @ 16" O.C. 4" THICK, 3000 P.S.I. CONCRETE SLAB REINF. W/ 6x6 #10/#10 W.W.M. OR FIBERGLASS ON CLEAN, DRY, TREATED, TERMITE COMPACTED EARTH FILL16" X 36"+/- (HT. VARIES CONCRETE STEM WALL W/4" CONCRETE MONOLITHIC SLAB OVER BUILT UP COMPACTED SOIL. INSTALL #5 VERTICAL BAR @ 18" O.C. MAX., 3000 PSI CONCRETE SLAB W/#5 REBAR CONT. OVERLAP ENDS 40 X DIA. MIN. EXTEND 6 X 6 X #10/#10 W.W.W. FROM CONCRETE SLAB INTO FOOTING SIMPSON HOLDDOWN CORNERS AS REQUIERED R19 OPEN CELL FOAM @ RAFTER DECK SIMPSON GALV. METAL HOLD-DOWN W/ 5/8" ANCHOR BOLT. LOCATE HOLD-DOWN AS PER PLAN LOCATION. ATTACH IN STRICT COMPLIANCE W/ MANUFACTURER & ENGINEERS SPECIFICATIONS. 5V METAL ROOF LOW PROFILE GALV. PREFINISHED METAL DRIP EDGE 1 X 8 S4S FASCIA CONT. (3) 2 X 12 PT WOOD BEAM BEAM BOX 2X8 SUB FASCIA 1 X 4 S4S TRIM + BLOCKING 2X6 PURLINS-CUT BETWEEN WOOD STUDS 48" O.C. FOR PLYWOOD SHEATHING REQUIREMENTS. R-19 INSULATION BETWEEN 2 X6 WD. STUDS @ 16" O.C. 1/2" OSB PLYWOOD SHEATHING W/ DUPONT "TYVEK WRAP" ON ENTIRE EXTERIOR, NAIL SHEATHING IN ACCORDANCE W/ IBC 2021 & ICC-600 HIGH WIND STANDARDS. FIRST SHEET TO BE P.T. 1X8 HARDIE PLANK HORIZONTAL SIDING W/6.25" EXPOSURE OLD SAVANNAH BRICK SIMPSON GALV. METAL HOLD-DOWN W/ 5/8" ANCHOR BOLT. LOCATE HOLD-DOWN AS PER PLAN LOCATION. ATTACH IN STRICT COMPLIANCE W/ MANUFACTURER AND ENGINEERS SPECIFICATIONS. 1/2" GYP. BOARD 6X6 PT WOOD BRACKET DESIGN FOR SHEET DATE: REVISION: DESIGNED BY DRAWN BY PROJECT -BLDG 5 RIGGS Ln- STE 208 Bluffton SC 29910 Ph. 561.359.7213 COPYRIGHT 2024 FSL DESIGNER, THE USE OF THE DOCUMENT(S) AND THE DESIGN CONTENT WITHOUT WRITTEN PERMISSION FROM FSL DESIGNER IS PROHIBITED. FSL DESIGNER HAS NOT BEEN HIRED FOR CONSTRUCTION OR OBSERVATION MANAGEMENT DATE: 09.08.2025 09.18.2025 02.28.2026 03.04.2026 04.02.2026 05.12.2026 06.22.2026 FINAL SET INITIALS OWNERS _______ BUILDER________ FSL Designer Residential Designers - Architects F. SUAREZ LYNCH FES 26-108 09-08-2025THE SPANISH WELLS GOLF CLUB HOUSE-REMODEL LOT# "BRAMS POINT ROAD -SPANISH WELLS PLANTATION " BEAUFORT COUNTY, HILTON HEAD SOUTH CAROLINA A4.2 NOTES: ALL STRUCTURAL MEMBERS & ANY EXTERIOR MATERIAL SHALL MEET OR EXCEED A 150 M.P.H. (MIN.) WIND LOAD & MEET OR EXCEED ALL BUILDIING CODES INCLUDING IBC 2021 W/SOUTH CAROLINA AMENDMENTS & 2009 IECC ENERGY CODES. CONTRACTOR TO HAVE FRAMING SYSTEM DESIGNED BY SUPPLIER AND REVIEWED BY STRUCTURAL ENGINEER PRIOR TO ORDER AND INSTALLATION. ALL STRAPPING DESIGN BY ENGINEER. 3/4" = 1'-0"1 OFFICE WALL SECTION 3/4" = 1'-0"2 FRONT PORCH SECTION Page 24 of 55 FIRST LEVEL F.F. FIRST LEVEL PLATE HT. COLUMN HEIGHT 8' - 0 1/2" 8' - 0" LOW PROFILE GALV. PREFINISHED METAL DRIP EDGE 1 X 8 S4S FASCIA CONT. 1 X 4 S4S TRIM + BLOCKING 2X8 SUB FASCIA SIMPSON HOLDDOWN CORNERS AS REQUIERED R19 OPEN CELL FOAM @ RAFTER DECK 5V METAL ROOF OLD SAVANNAH BRICK 2X6 WD. P.T. BOTTOM PLATE CONT. SIMPSON GALV. METAL HOLD-DOWN W/ 5/8" ANCHOR BOLT. LOCATE HOLD-DOWN AS PER PLAN LOCATION. ATTACH IN STRICT COMPLIANCE W/ MANUFACTURER AND ENGINEERS SPECIFICATIONS. SILL SEAL (3) 2 X 12 PT WOOD BEAM BEAM BOX OLD SAVANNAH BRICK 8X8 PT WOOD POST 16" X 36"+/- (HT. VARIES CONCRETE STEM WALL W/4" CONCRETE MONOLITHIC SLAB OVER BUILT UP COMPACTED SOIL. INSTALL #5 VERTICAL BAR @ 18" O.C. MAX., 3000 PSI CONCRETE SLAB W/#5 REBAR CONT. OVERLAP ENDS 40 X DIA. MIN. EXTEND 6 X 6 X #10/#10 W.W.W. FROM CONCRETE SLAB INTO FOOTING EXISTING WOOD DECK 1X8 HARDIE PLANK HORIZONTAL SIDING W/6.25" EXPOSURE R-19 INSULATION BETWEEN 2 X6 WD. STUDS @ 16" O.C. 1/2" OSB PLYWOOD SHEATHING W/ DUPONT "TYVEK WRAP" ON ENTIRE EXTERIOR, NAIL SHEATHING IN ACCORDANCE W/ IBC 2021 & ICC-600 HIGH WIND STANDARDS. FIRST SHEET TO BE P.T. 2X8 PT WOOD RAFTER I- ALUMINUM BEAM WINDOW HEAD 7' - 0" FIRST LEVEL F.F. FIRST LEVEL PLATE HT. GARAGE LEVEL F.F. SIMPSON HOLDDOWN CORNERS AS REQUIERED R19 OPEN CELL FOAM @ RAFTER DECK 5V METAL ROOF LOW PROFILE GALV. PREFINISHED METAL DRIP EDGE 1 X 8 S4S FASCIA CONT. 1 X 4 S4S TRIM + BLOCKING 2X8 SUB FASCIA 2X8 PT WOOD RAFTER (3) 2 X 12 PT WOOD BEAM BEAM BOX 8X8 PT WOOD POST OLD SAVANNAH BRICK EXISTING WOOD DECK OLD SAVANNAH BRICK 1X8 HARDIE PLANK HORIZONTAL SIDING W/6.25" EXPOSURE R-19 INSULATION BETWEEN 2 X6 WD. STUDS @ 16" O.C. 1/2" OSB PLYWOOD SHEATHING W/ DUPONT "TYVEK WRAP" ON ENTIRE EXTERIOR, NAIL SHEATHING IN ACCORDANCE W/ IBC 2021 & ICC-600 HIGH WIND STANDARDS. FIRST SHEET TO BE P.T. I- ALUMINUM BEAM DESIGN FOR SHEET DATE: REVISION: DESIGNED BY DRAWN BY PROJECT -BLDG 5 RIGGS Ln- STE 208 Bluffton SC 29910 Ph. 561.359.7213 COPYRIGHT 2024 FSL DESIGNER, THE USE OF THE DOCUMENT(S) AND THE DESIGN CONTENT WITHOUT WRITTEN PERMISSION FROM FSL DESIGNER IS PROHIBITED. FSL DESIGNER HAS NOT BEEN HIRED FOR CONSTRUCTION OR OBSERVATION MANAGEMENT DATE: 09.08.2025 09.18.2025 02.28.2026 03.04.2026 04.02.2026 05.12.2026 06.22.2026 FINAL SET INITIALS OWNERS _______ BUILDER________ FSL Designer Residential Designers - Architects F. SUAREZ LYNCH FES 26-108 09-08-2025THE SPANISH WELLS GOLF CLUB HOUSE-REMODEL LOT# "BRAMS POINT ROAD -SPANISH WELLS PLANTATION " BEAUFORT COUNTY, HILTON HEAD SOUTH CAROLINA A4.3 NOTES: ALL STRUCTURAL MEMBERS & ANY EXTERIOR MATERIAL SHALL MEET OR EXCEED A 150 M.P.H. (MIN.) WIND LOAD & MEET OR EXCEED ALL BUILDIING CODES INCLUDING IBC 2021 W/SOUTH CAROLINA AMENDMENTS & 2009 IECC ENERGY CODES. CONTRACTOR TO HAVE FRAMING SYSTEM DESIGNED BY SUPPLIER AND REVIEWED BY STRUCTURAL ENGINEER PRIOR TO ORDER AND INSTALLATION. ALL STRAPPING DESIGN BY ENGINEER. 3/4" = 1'-0"1 REAR PORCH SECTION 3/4" = 1'-0"2 REAR PORCH II SECTION Page 25 of 55 DESIGN FOR SHEET DATE: REVISION: DESIGNED BY DRAWN BY PROJECT -BLDG 5 RIGGS Ln- STE 208 Bluffton SC 29910 Ph. 561.359.7213 COPYRIGHT 2024 FSL DESIGNER, THE USE OF THE DOCUMENT(S) AND THE DESIGN CONTENT WITHOUT WRITTEN PERMISSION FROM FSL DESIGNER IS PROHIBITED. FSL DESIGNER HAS NOT BEEN HIRED FOR CONSTRUCTION OR OBSERVATION MANAGEMENT DATE: 09.08.2025 09.18.2025 02.28.2026 03.04.2026 04.02.2026 05.12.2026 06.22.2026 FINAL SET INITIALS OWNERS _______ BUILDER________ FSL Designer Residential Designers - Architects 26-108 09-08-2025THE SPANISH WELLS GOLF CLUB HOUSE-REMODEL LOT# "BRAMS POINT ROAD -SPANISH WELLS PLANTATION " BEAUFORT COUNTY, HILTON HEAD SOUTH CAROLINA A4.5 Page 26 of 55 ALL WINDOW SIZES ARE BASED ON MARVIN ELEVATE SERIES WINDOWS. CONTRACTOR TO VERIFY ALL ROUGH OPENINGS. ALL GLASS TO BE LOW E GLASS. WINDOW SUPPLIER SHALL CONFORM TO ALL CODES DESIGNATED. TEMPERED GLASS SHALL BE INSTALLED AS DICTATED BY CODE. CONTACT DESIGNER IF ANY DISCREPANCIES ARE FOUND BEFORE ORDERING. ALL WINDOWS SHALL MEET THE ENERGY STAR GUIDELINES AS A MINIMUM SUPPLIER TO FURNISH BUILDER WITH R.O. SCHEDULE NOTE ALL DOOR SIZES ARE NOMINAL. CONTRACTOR TO VERIFY ROUGH OPENINGS. ALL GLASS TO BE LOW E GLASS. DOOR SUPPLIER SHALL CONFORM TO ALL CODES DESIGNATED. TEMPERED GLASS SHALL BE INSTALLED AS DICTATED BY CODE. CONTACT DESIGNER IF ANY DISCREPANCIES ARE FOUND BEFORE ORDERING. ALL DOORS SHALL MEET THE ENERGY STAR GUIDELINES AS A MINIMUM SUPPLIER TO FURNISH BUILDER WITH R.O. SCHEDULE NOTE DESIGN FOR SHEET DATE: REVISION: DESIGNED BY DRAWN BY PROJECT -BLDG 5 RIGGS Ln- STE 208 Bluffton SC 29910 Ph. 561.359.7213 COPYRIGHT 2024 FSL DESIGNER, THE USE OF THE DOCUMENT(S) AND THE DESIGN CONTENT WITHOUT WRITTEN PERMISSION FROM FSL DESIGNER IS PROHIBITED. FSL DESIGNER HAS NOT BEEN HIRED FOR CONSTRUCTION OR OBSERVATION MANAGEMENT DATE: 09.08.2025 09.18.2025 02.28.2026 03.04.2026 04.02.2026 05.12.2026 06.22.2026 FINAL SET INITIALS OWNERS _______ BUILDER________ FSL Designer Residential Designers - Architects F. SUAREZ LYNCH FES 26-108 09-08-2025THE SPANISH WELLS GOLF CLUB HOUSE-REMODEL LOT# "BRAMS POINT ROAD -SPANISH WELLS PLANTATION " BEAUFORT COUNTY, HILTON HEAD SOUTH CAROLINA A5.0 WINDOW SCHEDULE SYM. WIDTH HEIGHT EGRESS Y/N DESCRIPTION DP RATING U-FACTOR SHGC A 4' - 0" 3' - 3 1/8" AWNING WIND OW CLAD W* E GLASS 40/45 .29 .29 B 2' - 9 1/2" 4' - 3 3/4" NO DOUBLE HUNG WINDOW CLAD W/ E GLASS 40/45 .29 .29 C 2' - 0" 2' - 3 1/8" NO PICTURE WIND OW CLAD W/ E GLASS 40/45 .29 .29 D 2' - 0" 6' - 9 1/2" NO PICTURE WIND OW CLAD W/ E GLASS 40/45 .29 .29 DOOR SCHEDULE NUMBER SIZE TYPE LOCATION DESCRIPTION DP RATING U-FACTO R SHGCWIDTH HEIGHT THICKNESS 1 5' - 11" 6' - 10" 1 3/4" EXT MAIN SALON OUTSWING FRENCH DOUBLE DOOR W/ E GLASS 40/45 .29 .29 2 3' - 0 5/16" 6' - 10" 1 3/4" EXT SHOP OUTSW ING FRENCH DOOR W/ E GLASS 40/45 .29 .29 2A 1' - 4" 6' - 8" 1 3/8" EXT SHOP 3/4 GLASS OVER SINGLE PANEL SIDELITE 40/45 .29 .29 2B 1' - 4" 6' - 8" 1 3/8" EXT SHOP 3/4 GLASS OVER SINGLE PANEL SIDELITE 40/45 .29 .29 3 5' - 11" 6' - 10" 1 3/4" EXT MAIN SALON OUTSWING FRENCH DOUBLE DOOR W/ E GLASS 40/45 .29 .29 4 19' - 0" 11' - 0" 1" EXT MAIN SALON Steel Bifold Door 40/45 .29 .29 5 3' - 0 5/16" 6' - 10" 1 3/4" EXT DAILY SALON OUTSWING FRENCH DOOR W/ E GLASS 40/45 .29 .29 6 3' - 0" 6' - 8" 1 3/8" EXT HALLWAY OUTSWING TRADITIONAL DOOR 40/45 .29 .29 7 3' - 0" 6' - 8" 1 3/8" INT MAIN SALON MDF SC PANEL SWING DOOR UNIT 8 5' - 0" 6' - 8" 1 3/8" INT HALLWAY MDF SC PANEL DOUBLE POCKET DOOR UNIT 9 2' - 10" 6' - 8" 1 3/8" INT IN - OUT HALL MDF SC PANEL SWING DOOR UNIT 10 2' - 10" 6' - 8" 1 3/8" INT IN - OUT HALL MDF SC PANEL SWING DOOR UNIT 11 3' - 0" 6' - 8" 1 3/8" INT STORA GE MDF SC PANEL SWING DOOR UNIT 12 3' - 0" 6' - 8" 1 3/8" INT LADIES RESTROOM MDF SC PANEL SWING DOOR UNIT 13 3' - 0" 6' - 8" 1 3/8" INT MEN RESTROOM MDF SC PANEL SWING DOOR UNIT 14 3' - 0" 6' - 8" 1 3/8" INT SHOP M DF SC PANEL SWING DOOR UNIT 15 3' - 0" 6' - 8" 1 3/8" INT SHOP M DF SC PANEL SWING DOOR UNIT 16 3' - 0" 6' - 8" 0" INT HALLWAY CASED OPENING 17 3' - 0" 6' - 8" 0" INT STORAGE CASED OPENING 18 4' - 6" 6' - 8" 0" INT IN - OUT HALL CASED OPENING 19 3' - 0" 6' - 8" 0" INT MAIN SALON CASED OPENING 20 3' - 0" 6' - 8" 0" INT MEN RESTROOM CASED OPENING 52 5' - 0" 6' - 8" 1 3/8" EXIST MAIN SALON Page 27 of 55 DOUBLE HUNG WINDOW DETAIL SCALE: 1"= 1'-0" 1 A5.1 1C A5.1 1B A5.1 1D A5.1 1A A5.1 1 1/2" 5 1/2" SEE WINDOW SCHEDULE WINDOW HEIGHT 3" WINDOW - SEE WINDOW SCHEDULE FOR MORE DETAILS TRIM 3 1/2"3 1/2" 3/4" 3/4" SEE WINDOW SCHEDULE WINDOW WIDTH DOUBLE HUNG WINDOW AS SPEC'D 1/2" GYPSUM BOARD 1/4" SHIM SPACE (3) 2X6 2X6 STUD WALL W/ R-19 INSULATION 1/2" OSB SHEATHING W/ "TYVEK" HOUSE WRAP ON ENTIRE EXTERIOR, NAIL SHEATHING ACCORDANCE W/ 2021 IRC & ICC 600 HIGH WIND STANDARDS 5/4 X 6 S4S WOOD #1 P.T. DURAPINE OR AZEK EDGE OF SILL BELOW 1C A5.1 SILL SCALE: 3" = 1'-0" 1B A5.1 MEETING RAIL SCALE: 3" = 1'-0" 1A A5.1 HEAD SCALE: 3" = 1'-0" 1D A5.1 JAMB SCALE: 3" = 1'-0" 1/4" MARGIN (TYP) 1/4" MARGIN (TYP) 1/2" OSB SHEATHING W/ "TYVEK" HOUSE WRAP ON ENTIRE EXTERIOR, NAIL SHEATHING ACCORDANCE W/ 2021 IRC & ICC-600 HIGH WIND STANDARDS 2X6 STUD WALL W/ R-19 INSULATION 1/2" GYPSUM BOARD HEADER AS SPEC'D PRE-FINISHED ALUM. FLASHING 1/4" SHIM SPACE BACKER ROD & CAULK DOUBLE HUNG WINDOW AS SPEC'D 1/4" MARGIN (TYP) DOUBLE HUNG WINDOW AS SPEC'D 1/4" SHIM SPACE BACKER ROD & CAULK 3X2 S4S (EXACT SIZE) #1 P.T. DURAPINE SILL PRE-FINISHED ALUM. FLASHING (2) 2X6 CONT. 1/2" GYPSUM BOARD 1/2" OSB SHEATHING W/ "TYVEK" HOUSE WRAP ON ENTIRE EXTERIOR, NAIL SHEATHING ACCORDANCE W/ 2021 IRC & ICC-600 HIGH WIND STANDARDS 2 3/4"1/4" 3" 2X6 STUD WALL W/ R-19 INSULATION 1X8 HARDIE HORIZONTAL PLANK SMOOTH CEMENTITOUS SIDING WITH 6-1/2" REVEAL 1X8 HARDIE HORIZONTAL PLANK SMOOTH CEMENTITOUS SIDING WITH 6-1/2" REVEAL 1X8 HARDIE HORIZONTAL PLANK SMOOTH CEMENTITOUS SIDING WITH 6-1/2" REVEAL SILICONE SEALANT 3/4" CAP RB 60 CROWN MOLDING 1 X 3-1/2 S4S TRIM RB 273 PICTURE MOLD 1X3 S4S TRIM BOARD 1 X 2 S4S #1 P.T. WOOD W/ 3/8" SLOPE 5/4 X 6 S4S WOOD #1 P.T. DURAPINE OR AZEK W/ 5-1/2" EXPOSURE DESIGN FOR SHEET DATE: REVISION: DESIGNED BY DRAWN BY PROJECT -BLDG 5 RIGGS Ln- STE 208 Bluffton SC 29910 Ph. 561.359.7213 COPYRIGHT 2024 FSL DESIGNER, THE USE OF THE DOCUMENT(S) AND THE DESIGN CONTENT WITHOUT WRITTEN PERMISSION FROM FSL DESIGNER IS PROHIBITED. FSL DESIGNER HAS NOT BEEN HIRED FOR CONSTRUCTION OR OBSERVATION MANAGEMENT DATE: 09.08.2025 09.18.2025 02.28.2026 03.04.2026 04.02.2026 05.12.2026 06.22.2026 FINAL SET INITIALS OWNERS _______ BUILDER________ FSL Designer Residential Designers - Architects F. SUAREZ LYNCH FES 26-108 09-08-2025THE SPANISH WELLS GOLF CLUB HOUSE-REMODEL LOT# "BRAMS POINT ROAD -SPANISH WELLS PLANTATION " BEAUFORT COUNTY, HILTON HEAD SOUTH CAROLINA A5.1 Page 28 of 55 2C A6.1 JAMB SCALE: 1-1/2" = 1'-0" 1/4" SHIM SPACE 5/4 X 4-9/16 S4S WOOD JAMB RB-34 MOLDING STOP CUSTOM WOOD ENTRY DOOR / SIDELIGHT 1/2" GYPSUM BOARD 2X6 STUD WALL W/ 5-1/2" R-19 BATT INSULATION 1/2" OSB SHEATHING W/ "TYVEK" HOUSE WRAP ON ENTIRE EXTERIOR, NAIL SHEATHING ACCORDANCE W/ 2021 IRC AND ICC 600 HIGH WIND STANDARDS 5/4 X 6 S4S WOOD #1 P.T. DURAPINE EDGE OF SILL BELOW (3) 2X6 A6.1 A6.1 CUSTOM WOOD ENTRY DOOR/SIDELIGHT RB-34 MOLDING STOP FACTORY SILL 3/4" T&G PLYWOOD 2A HEAD SCALE: 1-1/2" = 1'-0" 2B SILL SCALE: 1-1/2" = 1'-0" VERIFY R.O. W/ ENTRY DOOR MANF. 0' -2 3/4" 0' -0 3/8" 0' -2 3/8" 0' - 0 1/2" 0' -2" 2C A6.1 MULL SCALE: 1-1/2" = 1'-0" 1/4" MARGIN (TYP) 1/4" MARGIN (TYP) HEADER AS SPEC'D PREFINISHED ALUM. FLASHING 1 X 2 S4S #1 P.T. WOOD W/ 3/8" SLOPE 5/4 X 6 S4S WOOD #1 P.T. DURAPINE OR AZEK W/ 5-1/2" EXPOSURE 1/4" SHIM SPACE 5/4 X 4-9/16 S4S WOOD JAMB RB-34 MOLDING STOP CUSTOM WOOD ENTRY DOOR / SIDELIGHT 1/4" MARGIN (TYP) 1X8 HARDIE HORIZONTAL PLANK SMOOTH CEMENTITOUS SIDING WITH 6-1/2" REVEAL 1X8 HARDIE HORIZONTAL PLANK SMOOTH CEMENTITOUS SIDING WITH 6-1/2" REVEALFIRST LEVEL F.F. DESIGN FOR SHEET DATE: REVISION: DESIGNED BY DRAWN BY PROJECT -BLDG 5 RIGGS Ln- STE 208 Bluffton SC 29910 Ph. 561.359.7213 COPYRIGHT 2024 FSL DESIGNER, THE USE OF THE DOCUMENT(S) AND THE DESIGN CONTENT WITHOUT WRITTEN PERMISSION FROM FSL DESIGNER IS PROHIBITED. FSL DESIGNER HAS NOT BEEN HIRED FOR CONSTRUCTION OR OBSERVATION MANAGEMENT DATE: 09.08.2025 09.18.2025 02.28.2026 03.04.2026 04.02.2026 05.12.2026 06.22.2026 FINAL SET INITIALS OWNERS _______ BUILDER________ FSL Designer Residential Designers - Architects F. SUAREZ LYNCH FES 26-108 09-08-2025THE SPANISH WELLS GOLF CLUB HOUSE-REMODEL LOT# "BRAMS POINT ROAD -SPANISH WELLS PLANTATION " BEAUFORT COUNTY, HILTON HEAD SOUTH CAROLINA A6.1 1" = 1'-0"2 DOOR ELEVATION - Page 29 of 55 SS S SS SSS SSS S 3 S 3 SS S S S S S S S S CO S CO S CO S CO S S S REF. CHAMBER #1 REF. CHAMBER #2 S S 2-150 AMP PANELS 52" FAN ELECTRICAL LEGEND (SPEED CONTROL) 110V DIMMER SWITCH REOSTAT SWITCH CEILING FAN DOOR SWITCH LIGHT FIXTURE SURFACE MTD. LIGHT FIXTURE SINGLE POLE SWITCH FOUR WAY SWITCH THREE WAY SWITCH DESCRIPTION 110V 110V 110V DOOR CHIMEPLUGM OLD PHONE OUTLET WATER PROOF UNDER CABINET LIGHTING CABLE T.V. OUTLET LOCATE AS DIRECTED BY OWNER DUPLICATE ORDER 3 SYM D R 4 DS LAD D.O. WP P DC T.V. DUPLEX CEILING OUTLET DUPLEX RECEPTACLE RECESSED LIGHT FIXTURE HEAT/LIGHT/ FAN FIXTURE FLUORESCENT JUNCTION BOX 220V RECEPTACLE FLOOD LIGHT WATER PROOF SWITCH WIRED DUPLEX RECEPT. DUPLEX FLOOR OUTLET SMOKE DETECTOR CARBON DIOXIDE DETECTOR WALL MOUNT S CO S S S S S S J CF GENERAL ELECTRICAL NOTES 1) GENERAL CONTRACTOR SHALL REFER TO ARCHITECTURAL FLOOR PLAN(S), SHEET NO. A2.0, A2.1, A2.2 FOR FINISHES, DIMENSIONS, VERIFICATION, ETC 2) PROVIDE TELEVISION OUTLETS, LOCATE BY OWNER. 3) PROVIDE TELEPHONE OUTLETS, LOCATE BY OWNER. 4) QUANTITIES OF FIXTURES TO BE SELECTED AND APPROVED BY OWNER. SUPPLY TO BUILDER FOR PRICING. 5)PROVIDE ELECTRICITY TO ALL EQUIPMENT, FIXTURES, ETC. NOT SPECIFICALLY NOTED OR SHOWN. 6) PROVIDE ELEC./BATTERY BACK-UP SMOKE DETECTORS AS DIRECTED, SMOKE DETECTORS, INTERCONNECTED 110 VOLT BATTERY BACKUP LOCATED AT EACH SLEEPING AREA AND FLOOR 7) PROVIDE C/O DETECTORS AS REQUIRED. LOCATE AS DIRECTED. 8) ALL ELECTRICAL WORK SHALL CONFORM TO ALL LOCAL, STATE, AND FEDERAL CODES INCLUDING THE CURRENT EDITION OF THE NATIONAL ELECTRICAL CODE GFCI PROTECTION REQUIRED FOR RECEPTACLES IN BATHROOMS, GARAGES OUTDOORS, AND WITHIN 6 FEET OF A SINK. 9) LOCATE ELECTRICAL SERVICE PANEL AS CLOSE AS POSSIBLE TO THE POINT OF ENTRANCE OF THE SERVICE CONDUCTORS 10) HEAT PUMP DISCONNECTS, REQUIRED AT ALL AIR HANDLING & CONDENSING UNITS, UNLESS IN VIEW OF PANEL BOX 11) OUTSIDE DISCONNECT REQUIRED WITH 4 WIRE LEAD TO PANEL UNLESS PANEL & METER CAN ARE BACK TO BACK 12) PROVIDE 50% FLORESCENT OR LED PER IECC2009 CODE 13) PROVIDE TAMPER RESISTANT RECEPTACLES AS LISTED IN NEC SECTION E4002.14 14) ALL RECEPTACLES IN THE GARAGE SHALL BE LOCATED ABOVE BFE PER NEC SECTION 322.16 15) ALL 120 VOLTS CIRCUITS THAT ARE NOT REQUIRED TO BE GFCI PROTECTED SHALL ARC-FAULT PROTECTED PER NEC SECTION 3902.15-.17 16) ALL GROUNDING POINTS FOR THE ELECTRICAL SERVICE SHALL BE UTILIZED PER NEC 3608.1 17) GFI RECEPTACLES SHALL BE INSTALLED ACCORDING TO NEC E3902.1- E3902.14 DESIGN FOR SHEET DATE: REVISION: DESIGNED BY DRAWN BY PROJECT -BLDG 5 RIGGS Ln- STE 208 Bluffton SC 29910 Ph. 561.359.7213 COPYRIGHT 2024 FSL DESIGNER, THE USE OF THE DOCUMENT(S) AND THE DESIGN CONTENT WITHOUT WRITTEN PERMISSION FROM FSL DESIGNER IS PROHIBITED. FSL DESIGNER HAS NOT BEEN HIRED FOR CONSTRUCTION OR OBSERVATION MANAGEMENT DATE: 09.08.2025 09.18.2025 02.28.2026 03.04.2026 04.02.2026 05.12.2026 06.22.2026 FINAL SET INITIALS OWNERS _______ BUILDER________ FSL Designer Residential Designers - Architects F. SUAREZ LYNCH FES 26-108 09-08-2025THE SPANISH WELLS GOLF CLUB HOUSE-REMODEL LOT# "BRAMS POINT ROAD -SPANISH WELLS PLANTATION " BEAUFORT COUNTY, HILTON HEAD SOUTH CAROLINA E2.1 1/4" = 1'-0"1 ELECTRICAL FIRST FLOOR PLAN NORTH Page 30 of 55 DESIGN FOR SHEET DATE: REVISION: DESIGNED BY DRAWN BY PROJECT -BLDG 5 RIGGS Ln- STE 208 Bluffton SC 29910 Ph. 561.359.7213 COPYRIGHT 2024 FSL DESIGNER, THE USE OF THE DOCUMENT(S) AND THE DESIGN CONTENT WITHOUT WRITTEN PERMISSION FROM FSL DESIGNER IS PROHIBITED. FSL DESIGNER HAS NOT BEEN HIRED FOR CONSTRUCTION OR OBSERVATION MANAGEMENT DATE: 09.08.2025 09.18.2025 02.28.2026 03.04.2026 04.02.2026 05.12.2026 06.22.2026 FINAL SET INITIALS OWNERS _______ BUILDER________ FSL Designer Residential Designers - Architects FES 26-108 09-08-2025THE SPANISH WELLS GOLF CLUB HOUSE-REMODEL LOT# "BRAMS POINT ROAD -SPANISH WELLS PLANTATION " BEAUFORT COUNTY, HILTON HEAD SOUTH CAROLINA AD.13/4" = 1'-0"1 ADA FLASHING DETAILS Page 31 of 55 DW 1ST FL 13.8 NAVD88 FP 13.67 NAVD88 RP 13.8 NAVD88 19' - 8" SPACE FOR APPLIANCES 3' - 1"3' - 1" VAULTED 12' - 0" SERVICE YARD REF. CHAMBER #1 REF. CHAMBER #2 LIFT DIRTY DISHES CLEAN DISHES CLEAN DISHES DELIVER ZONE PREPARATION ZONE EXTERIOR BARREAR PORCH FRONT PORCH 5' - 0" 6' - 8" 3' - 0" ADA TOILET 5' - 4" 6' - 4" 3' - 0" 1' - 2" 1' - 2" ADA TOILET 3' - 0" 12' - 3 11/16" 8' - 2 9/16" 21' - 6 1/2" 11' - 10 1/2" 9' - 2 3/4" 9' - 5 3/4" 75' - 9" 10' - 10 1/16" 7' - 2 3/16" 1' - 0" 12' - 8"7' - 0 1/2"4' - 6 9/16" 18' - 10 3/4" 8' - 10" 8 1/2" 8' - 9 1/2" 8' - 9 1/2" 8' - 9 1/2" 7 3/4" 5' - 0 1/8" 8' - 10 1/4" 8' - 10 1/4" 5' - 0 1/8" 27' - 8 3/4" 29' - 4" 3' - 4 1/2" 4' - 2" 10' - 10 9/16" 13' - 5 15/16" 61' - 3" 31' - 0" 10 3/4" 10' - 1 1/2" 9' - 3" 10' - 1" 7 3/4" 5' - 7 3/4" 19' - 8 1/2" 5' - 7 3/4" 13' - 5 15/16"10' - 9 1/16" 22' - 1 1/4" 24' - 3 1/16" 3' - 0"3' - 0" STUCCO FINISH FIRE PLACE WALLS 12' - 5 1/16" 74' - 10 5/8" 15 11 7 MAIN SALON WOOD BAR TILE DAILY SALON WOOD STORAGE II TILE ELECTRICAL ROOM TILE HALLWAY TILE STORAGE TILE 2' - 6" 6' - 6 5/8" 4' - 0" 6' - 6 5/8" 2' - 6" 1' - 2 1/4" 1' - 2 1/4" BBBB BBBB 2' - 3 7/8" 2' - 9 1/2" 5' - 11 1/4" 5' - 11 1/4" 2' - 9 1/2" 2' - 3 7/8" 34' - 11" 26' - 4" 5' - 0 1/2" 5' - 0 1/2" 1' - 2 1/4" 1' - 2 1/4" 2' - 3 1/4" 11' - 2 5/16" 6' - 4" 9' - 0 7/8" 38' - 7" 1ST FL 13.8 NAVD88 HOOD 2-150 AMP PANELS 2' - 6 1/2" 7' - 1" PLANTERS PLANTERS VAULTED VAULTED SHOP WOOD OFFICE WOOD 52 2A2B9' - 2 1/2" 9' - 2 1/2" 16' - 6 1/2" 12' - 9 1/2" 9' - 7 1/2"9' - 0" 12' - 9 1/2"22' - 6 1/2" 9' - 6 1/2" 6' - 10 3/16" 25' - 5 1/2" 10' - 9" 5' - 3" 8' - 10" 3' - 5" 9' - 7"12' - 0 5/8" 9' - 0" 5' - 4" 13' - 5" 2' - 10" 10' - 3"3' - 3" 12' - 11 7/16" 15' - 8"9' - 6" 33' - 9" 31' - 11 1/2" 22' - 6 1/2" 19' - 8 1/2" EXIT EXIT EXIT EXIT EXIT EXIT EXIT EXIT EXIT EXIT EXIT FE FE FE FE FE FE SM SM SM SM FIRE EXTINGUISHER EXIT EXIT LT SAFETY PLAN MAP (SM) MEETING POINT - PARKING LOT EXIT 9' - 10" 22' - 2" DESIGN FOR SHEET DATE: REVISION: DESIGNED BY DRAWN BY PROJECT -BLDG 5 RIGGS Ln- STE 208 Bluffton SC 29910 Ph. 561.359.7213 COPYRIGHT 2024 FSL DESIGNER, THE USE OF THE DOCUMENT(S) AND THE DESIGN CONTENT WITHOUT WRITTEN PERMISSION FROM FSL DESIGNER IS PROHIBITED. FSL DESIGNER HAS NOT BEEN HIRED FOR CONSTRUCTION OR OBSERVATION MANAGEMENT DATE: 09.08.2025 09.18.2025 02.28.2026 03.04.2026 04.02.2026 05.12.2026 06.22.2026 FINAL SET INITIALS OWNERS _______ BUILDER________ FSL Designer Residential Designers - Architects F. SUAREZ LYNCH FES 26-108 09-08-2025THE SPANISH WELLS GOLF CLUB HOUSE-REMODEL LOT# "BRAMS POINT ROAD -SPANISH WELLS PLANTATION " BEAUFORT COUNTY, HILTON HEAD SOUTH CAROLINA S1.11/4" = 1'-0"1 FIRST LEVEL F.F. SAFETY PLAN Page 32 of 55 WREVISIONS BY DATELACOMBEENGINEERINGMICHAEL S. LACOMBE, P.E.CIVIL / STRUCTURAL(843) 298-0368 / LACOMBE.PE@GMAIL.COM ENGINEERING 12345678910111213141516171819202122232425262728 123456789101112131415161718192021222324252627282930 2930 DRAWN BY:DATE:CHECKED BY:PROJECT #:SCALE:S26041SHOWNMSL06/05/2026 MSLADDITION AND REMODEL:HILTON HEAD ISLAND, SCGOLF CLUBHOUSESPANISH WELLS1 BRAMS POINT ROADGENERAL NOTESS-100ANDDETAILS 1. FRAMING MEMBERS TO BE SOUTHERN YELLOW PINE NO. 2 OR BETTER, UON. WALLSTUDS SHALL BE NO. 2 OR BETTER.2. WHERE SHEARWALL PANELS ARE INDICATED HEREIN, USE THE FOLLOWING GRADESTAMPED PLYWOOD:WALLS: 1532" APA STRUCTURAL RATED.3. ALL NAILS SHALL BE COMMON WIRE TYPE 10P MINIMUM WITH FULL HEADS. DO NOTDRIVE SHEATHING NAILS CLOSER THAN 38" FROM PANEL EDGE.4. ALL WALL AND PARTITION STUDS TO BE PLACED NO FURTHER THAN16" O.C.5. ALL WALL SHEATHING SHALL BE INSTALLED WITH THEIR LONG DIMENSION PERPENDICULARTO THE FLOOR AND ALL END JOINTS SHALL BE STAGGERED 2' (MIN.). NO SHEATHINGMEMBERS LESS THAN 2' LONG SHALL BE INSTALLED.6. WALL SHEATHING SHALL BE BLOCKED BETWEEN PLYWOOD EDGES SO AS TO PREVENT ANUNSUPPORTED PANEL EDGE.7. ALL WOOD IN CONTACT WITH CONCRETE SHALL BE PRESSURE TREATED.9. CONTRACTOR SHALL ENSURE THAT NO HOLES OR OPENINGS LARGER THAN 1 12" DIA.ARE MADE IN FRAMING MEMBERS THAT ARE NOT APPROVED BY THE ENGINEER. NOCUTS ARE ALLOWED ALONG THE EDGES OF ANY FRAMING MEMBER. ALL ALLOWEDHOLES SHALL BE ALONG THE CENTERLINES OF THE MEMBERS AND SHALL NOT BEPERFORMED WITHIN THE OUTERMOST THIRD OF THE MEMBER'S LENGTH UNLESSAPPROVED BY THE ENGINEER.10.ALL STRUCTURAL WALL PANELS (EXTERIOR SHEATHING) SHALL BE INSTALLED USING10D COMMON NAILS SPACED NO FURTHER THAN 3" O.C. AT EDGES AND 6" O.C.INTERIOR. STAGGER EDGE NAILS WITH THOSE OF ADJACENT PANELS. MAINTAIN 2"O.C. SPACING AT ALL OPENINGS AND PENETRATIONS. BLOCK ALL PANEL EDGES.11.INTERIOR DRYWALL OR PLYWOOD PANELING (ON EXTERIOR WALLS) MUST BE APPLIEDAS FOLLOWS: ATTACHMENT WITH 5D COOLER NAILS SHALL BE NO GREATER THAN 7"O.C. EDGES AND 10" O.C. FIELD. ALTERNATE ATTACHMENT SHALL BE BY #6 TYPE SOR W 1 14" LONG DRYWALL SCREWS SPACED NO GREATER THAN 8" O.C. EDGES AND12" O.C. FIELD. BLOCK ALL DRYWALL / PANEL EDGES. SHEARWALL FRAMING NOTES:BASIS FOR STRUCTURAL DESIGN ARE THE 2026 EDITIONOF THE INTERNATIONAL RESIDENTIAL AND BUILDINGCODES (IRC & IBC) SC ADOPTED VERSIONS AND ALLREFERENCED DOCUMENTS THEREIN.THE DESIGN DEPICTED HEREIN MEETS DEAD, LIVE, ANDWIND LOADS FOR THE LOCATION LISTED IN THISDRAWING'S TITLE AND SHALL NOT BE APPLICABLE TO ANYOTHER LOCATION.THE ARCHITECT OR CONTRACTOR SHALL NOTIFY THEENGINEER IMMEDIATELY OF ANY DEVIATION FROM ORMODIFICATION TO THIS DESIGN - ESPECIALLY ANYALTERATION WHICH MAY COMPROMISE THE LOADCONDITIONS OF THE STRUCTURE IN WHOLE OR PART.IT IS THE RESPONSIBILITY OF THE CONTRACTOR TOENSURE THAT NO CONSTRUCTION DISCIPLINES ALTER ORDEGRADE THE STRUCTURAL INTEGRITY INHERENT IN THISDESIGN.REFER TO ARCHITECTURAL PLANS FOR ALL CRITICALDIMENSIONS, DETAILS ETC.NOTE: IT IS THE SOLE RESPONSIBILITY OF THE WINDOWAND DOOR MANUFACTURERS OR OTHERS TO COMPLYWITH THE GOVERNING CODES AND LOADS FOR THEIRCOMMODITY'S DESIGN. ALL WINDOWS AND DOORSMUST COMPLY WITH SECTION 1609 (ENTIRE) OF IBC / IRC- (LATEST ADOPTED) FOR THIS LOCATION INCLUDINGHURRICANE PROTECTIONS. GENERAL STRUCTURAL NOTES:1. DEAD LOADS: ACTUAL CALCULATED.2. LIVE LOADS:ROOF - 20 PSFFLOOR - 40 PSFATTIC - 20 PSF (W/ STORAGE)BALCONIES & DECKS - 60 PSF3. REQUIRED SOIL BEARING PRESSURE - 2000 PSF.4. FLOOD LOADS - N/A5. WIND LOAD (ASCE/SEI 7-22, STRENGTH DESIGN):BASIC WIND SPEED - 140 MPHEXPOSURE D6. SHEAR DESIGN - AWC SPECIAL DESIGN PROVISIONSFOR WIND AND SEISMIC (SDPWS) -LATESTADOPTED EDITION.DESIGN LOADS: 1. CONCRETE - f'c=3000 PSI (GRANITE AGGREGATE).2. REINFORCING STEEL (ASTM A615) - fy= 60 KSI.3. STRUCTURAL STEEL (ASTM A992) - fy=50 KSI.4. BOLTS IN WOOD - ASTM A325 (GALV.).5. BOLTS IN CONCRETE - ASTM A307(GALV.).NOTE: ALL EXPOSED STEEL TO BE GALVANIZED OR EQUAL.MATERIAL PROPERTIES: MINIMUM NAILING SCHEDULEFRAMING MEMBERSNAILINGJOIST TO BEARING - TOE NAIL EACH SIDE(2) 16DDOUBLE JOISTSBLOCKED APART-EACK BLOCK, EACH SIDE(2) 16DBLOCKING BETWEEN JOISTSTO BEARING MEMBER-TOE NAIL EACH SIDE(2) 16DTO JOISTS 2 X 10 AND GREATER:(3) 20DTHROUGH NAIL (ONE END)(3) 16DTOE NAIL - EACH (OPPOSITE SIDE)TO JOISTS 2 X 8 AND LESS:THROUGH NAIL (ONE END)TOE NAIL - EACH (OPPOSITE SIDE)(3) 16D(2) 16DBRIDGING TO JOISTS - TOE NAIL EACH SIDE(2) 8DSTUDS TO BEARING - TOE NAIL EACH SIDE(2) 16DMULTIPLE STUDS - (INTERNAL - STAGGERED)16D @ 12" O.C.CORNER STUDS AND ANGLES16D @ 12" O.C.DOUBLE TOP PLATESLOWER PLATE TO TOP OF STUD(3) 16DUPPER PLATE TO LOWER PLATE (STAGGERED)(3) 16DUPPER PLATE TO LOWER PLATE(AT INTERSECTION)16D @ 16" O.C.AT LAP SPLICES(8) 16DBOTTOM PLATE TO JOISTS OR BLOCKING16D @ 16" O.C.EXTERIOR DOOR & WINDOW HEADER SCHEDULEFRAMING MEMBERS (MINIMUM)# OF STUDS AT EA.END OF HEADER(3) 2 X 8'S W/ (2) 12" PLYWOODFILLER - UP TO 4' OPENING(2) 2 X 6'S(3) 2 X 10'S W/ (2) 12" PLYWOODFILLER - UP TO 8' OPENING(2) 2 X 6'S(3) 2 X 12'S W/ (2) 12" PLYWOODFILLER - UP TO 10' OPENING(3) 2 X 6'SSEE FRAMING PLAN FOR LONGER SPANS AND CONDITIONS.NOTE: DO NOT SCALE THESE DRAWINGS. SEEARCHITECTS DRAWINGS FOR ALL CRITICAL DIMENSIONS. WINDOW DP RATINGS (140 MPH WIND)WINDOWOPENING AREA(SQ. FT.)140 MPHLOCATION10DP-40CENTER OF WALL20DP-40CENTER OF WALL50DP-35CENTER OF WALL100DP-35CENTER OF WALL500DP-35CENTER OF WALL10DP-50WITHIN 4 FT. OF CORNER20DP-45WITHIN 4 FT. OF CORNER50DP-40WITHIN 4 FT. OF CORNER100DP-40WITHIN 4 FT. OF CORNER500DP-30WITHIN 4 FT. OF CORNER NOT TO SCALE SIMPSON "HRS416Z" STRAP (OR "CS16" ASSPECIFIED) AT ALL HEADER / JACKLOCATIONS OF WALL OPENINGS.SIMPSON "H10A" OR DBL "H2.5A" TIESAT EACH RAFTER LOCATIONELEVATED FLOOR CONDITION IF DESIRED(RIM JOIST NOT SHOWN FOR CLARITY).SEE HEADER SCHEDULE FOR NUMBER OF SISTER STUDSREQ'D AT EACH OPENING. FRAMING, STRAPS & CLIPS GENERAL DETAILS OPENING58"Ø X 10" ANCHOR BOLTS W/ 3"SQUARE GALV. WASHERS 48" O.C.TYP. ALL EXTERIOR WALLS.SIMPSON "HDU8'S" W/ 58"Ø THREADEDANCHOR. EMBED 8" MINIMUM INTOFOUNDATION EPOXY AT EACH CORNER ANDOPENING WIDTH GREATER THAN 10'-0". SEESTRUCTURAL FRAMING PLAN FOR DETAILS. CLG. JOIST TYP.LOOKOUTS 16" O.C. W/SIMPSON "H10A" CLIPS(WHEN GABLES PRESENT).FLY RAFTER TYP. (ATGABLE CONDITIONS).CLG. JOISTS (IF DESIRED). SEE SHEARWALL DETAIL THIS PAGE FORSHEATHING NAILING REQUIREMENTS ATALL EXTERIOR WALLSCONCRETE FOUNDATION TYP. RAFTER TYP.10P NAILS 3" O.C.EDGES, 6"O.C.FIELD (INSIDE & OUT) TYPICAL .2 X 6 PURLINS AT ALLSHEATHING EDGES SLAB 2 X 6 SYP STUDWALL.STUDS 16" O.C.DBL. TOP PLATE.2 X 6 END/CORNER STUD TOBE SECURED16P NAILS 8"O.C. TYP. BOTH END STUDS. SHEARWALL DETAILNOT TO SCALEFOUNDATION ANCHORS - SEEFOUNDATION PLAN & DETAILS MIN. 12" CDX APA SHEATHINGHEADER Page 33 of 55 WREVISIONS BY DATELACOMBEENGINEERINGMICHAEL S. LACOMBE, P.E.CIVIL / STRUCTURAL(843) 298-0368 / LACOMBE.PE@GMAIL.COM ENGINEERING 12345678910111213141516171819202122232425262728 123456789101112131415161718192021222324252627282930 2930 DRAWN BY:DATE:CHECKED BY:PROJECT #:SCALE:S26041SHOWNMSL06/05/2026 MSLADDITION AND REMODEL:HILTON HEAD ISLAND, SCGOLF CLUBHOUSESPANISH WELLS1 BRAMS POINT ROADXS-101ANDDETAILS NOTE: ALL METAL ANCHORS & STRAPS SHOWN TO BE SIMPSON STRONG TIE CONNECTORS. CONNECTORS SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURERS INSTRUCTIONS. ALL EXPOSED CONNECTORS TO BE GALVANIZED.SIMPSON HANGER "LUS210"FOR ALL SYP JOISTS TO BEAMS,RIM-JOISTS AND CLEATS TYP. FILL ALL HOLESPER MFR'SREQUIREMENTS. SIMPSON TIE "H2.5A"AT ALL RAFTER TO TOP-PLATE CONNECTIONS FILL ALL HOLES PERMFR'S REQUIREMENTS. NOT TO SCALENOT TO SCALESIMPSON HANGER "IUS1.88 /11.88"AT EACH TJI CLG. JOIST TO BEAM ABOVE DINING AREA BEND & NAIL TAB(WHERE POSSIBLE)FILL ALL HOLESPER MFR'SREQUIREMENTS.NOT TO SCALE AT POST TOP TO GLULAM BEAM CONNECTIONSSIMPSON CLIP "CCQ96SDS2.5 "NOT TO SCALE SIMPSON "LRU28Z"(AT ALL RAFTER TOPS) FILL ALL HOLES PERMFR'S REQUIREMENTS.(6) FULL-LENGTH 2 X 6SYP STUDS.DOUBLE PLATE(6) FULL-LENGTH 2 X 6SYP STUDS.AT POST TOP TO GLULAM BEAM ENDS(2) SIMPSON CLIPS "H6 "NOT TO SCALE FILL ALL HOLES PERMFR'S REQUIREMENTS.DOUBLE PLATE(2) CLIPS TYP.NOT TO SCALE SIMPSON PLATE "LCE4"AT BASES OF SUPPORT COLUMNS SPECIFIEDNOT TO SCALE FILL ALL HOLES PERMFR'S REQUIREMENTS.CLIPS ON OPPOSITECORNERS TYP. SIMPSON PLATE "CS16"ALL EXTERIOR WALL OPENINGS GREATERTHAN 24" WIDENOT TO SCALEFILL ALL HOLES PERMFR'S REQUIREMENTS.HEADERMIN.11"DOWN JACKFULL HEADERWIDTHMIN. 3""CS16"JACK STUDTOP PLATE)CRIPPLE (OR DBL. SIMPSON "BC8"AT PORCH BEAM TO POSTS CONNECTIONSNOT TO SCALESIMPSON "BC8"MULTI-PLY LVL BEAMP.T.8X8'SFILL ALL HOLES PERMFR'SREQUIREMENTS. Page 34 of 55 WREVISIONS BY DATELACOMBEENGINEERINGMICHAEL S. LACOMBE, P.E.CIVIL / STRUCTURAL(843) 298-0368 / LACOMBE.PE@GMAIL.COM ENGINEERING 12345678910111213141516171819202122232425262728 123456789101112131415161718192021222324252627282930 2930 DRAWN BY:DATE:CHECKED BY:PROJECT #:SCALE:S26041SHOWNMSL06/05/2026 MSLADDITION AND REMODEL:HILTON HEAD ISLAND, SCGOLF CLUBHOUSESPANISH WELLS1 BRAMS POINT ROADFOUNDATIONS-200PLAN ANDDETAILS AS-201 AS-2011. THE FOUNDATION SHALL BE PLACED ON UNDISTURBED SOIL OR SOILSHAVING BEARING CAPACITY WITH SAFE WORKING VALUES DESIGNATED BYTHE ENGINEER AND SHALL BE FREE OF ORGANIC MATERIAL. IF PORTIONSOF THE FOUNDATION IS ON PREPARED FILL, A LICENSED SOILS TESTINGLABORATORY SHALL VERIFY SUITABILITY OF THE FILL FOR USE AND ITSFOUNDATION BEARING CAPACITY. THE CONTRACTOR IS RESPONSIBLE FORVERIFYING THE CONDITIONS OF THE SOIL PRIOR TO COMMENCING WORKAND NOTIFYING THE ENGINEER OF ANY DISCREPANCIES IN THIS DESIGNSTANDARD IMMEDIATELY.2. ALL FOOTINGS TO BE DESIGNED FOR AN ASSUMED SOIL PRESSURE OF2000 P.S.F. OWNER AND / OR CONTRACTOR TO HAVE SOIL PRESSUREVERIFIED AND IF CONTACT PRESSURE IS LESS THAN 2000 P.S.F.FOUNDATION SHALL BE REDESIGNED. COMPACT FILL SOIL TO 95%STANDARD DENSITY IN ACCORDANCE WITH ASTM D-1557 DOWN TO 2'-0"BELOW ALL SLABS & FOOTINGS.3. ALL LUMBER IN CONTACT WITH MASONRY OR CONCRETE SHALL BEPRESSURE TREATED.4. CONTRACTOR SHALL VERIFY LOCATIONS OF ALL OPENINGS, SLEEVES,ANCHOR BOLTS, INSERTS, ETC. AS REQUIRED BY OTHER TRADES BEFORECONCRETE IS PLACED. NO SLEEVES, OPENINGS OR INSERTS MAY BEPLACED IN BEAMS OR SLABS UNLESS APPROVED BY THE ENGINEER.5. ALL REINFORCING DETAILS TO CONFORM TO "MANUAL OF STANDARDPRACTICE FOR DETAILING REINFORCED CONCRETE STRUCTURES, ACI 315UNLESS DETAILED OTHERWISE ON STRUCTURAL DRAWINGS.6. PROVIDE SPACERS, CHAIRS, BOLTERS, ETC. AS REQUIRED TO ASSEMBLE,PLACE AND SUPPORT ALL REINFORCING SHOWN. FOUNDATION REQUIREMENTS: 1. SOILS BENEATH ALL NEW FOOTINGS AND SLABS SHALL BE PROPERLYCOMPACTED TO MINIMUM 95% STANDARD PROCTOR DENSITY ANDSHALL BE CAPABLE OF BEARING AT LEAST 2,000 PSF. COMPACTIONTESTS SHALL BE PERFORMED BY AN INDEPENDENT SOIL TESTINGLABORATORY AT RANDOM LOCATIONS. TEST RESULTS SHALL BEREVIEWED AND APPROVED BY THE ENGINEER PRIOR TO PLACEMENT OFCONCRETE. NOTIFY ENGINEER OF ANY UNDESIRABLE SOIL CONDITIONSIMMEDIATELY.2. ALL CONCRETE TO BE 3,000 PSI AT 28 DAYS.3. RE-STEEL TO BE 60 KSI YIELD. ALL RE-STEEL TO BE IN ACCORDANCE WITHACI-318 (LATEST).4. LAP ALL RE-STEEL 36 BAR DIAMETERS FOR TENSION. LAP ALL RE-STEEL 24BAR DIAMETERS FOR COMPRESSION. KEEP ALL REBAR 3" MIN. FROMBOTTOM AND SIDES OF FOOTINGS.5. ATTACH GALVANIZED THREADED ANCHORS AND REBARS (WHERE USED)AND REBARS WITH SIMPSON "AT-3G" EPOXY OR EQUAL IN CONCRETEHARDENED FOR AT LEAST 7 DAYS AT THE DEPTH SPECIFIED ON THISDRAWING. ALLOW EPOXY TO FULLY CURE PRIOR TO ANCHOR CLIPATTACHMENT OR TIGHTENING. DO NOT DISTURB ANCHORS DURING EPOXYCURING. FOLLOW THE EPOXY MFR'S. INSTRUCTIONS PRECISELY -ESPECIALLY CONCERNING THEIR REQUIREMENTS REGARDING HOLECLEANING AND PREPARATION. CONCRETE NOTES: AS-202 AS-202 BS-202 BSIMPSON®"HDU8" EACH EXT.OUTSIDE CORNER TYPICAL 58"Ø X 14" LANCHORBOLTS W/ 3"SQ. GALV.WASHERS 48"O.C. TYP. ALLEXTERIORWALLS. 18'-4 12"29'-11" ES-201 ES-201 S-202 CS-201 CS-201 FOUNDATION PLANSCALE: 14"=1'-0"NOTE: DO NOT SCALE ANY PORTION OF THISDRAWING NOT SPECIFICALLY NOTED. SEEARCHITECTS DRAWINGS FOR ALL CRITICALDIMENSIONS. 1. STRUCTURAL FILL: STRUCTURAL FILL SHALL CONSIST OF AN INORGANIC,NON-PLASTIC, NON-CLAY, GRANULAR SOIL CONTAINING LESS THAN 10PERCENT MATERIAL PASSING THE NO. 200 MESH SIEVE (RELATIVELYCLEAN SAND) WITH A UNIFIED SOIL CLASSIFICATION OF SW-SM ORSP-SM.2. SUITABLE BACKFILL MATERIAL: BACKFILL MATERIAL SHALL BE CLEAN AND FREEFROM ALL ORGANIC MATERIAL,CLAY, MARL OR UNSTABLE MATERIALS, DEBRIS,LUMPS, OR BROKEN PAVING. NO ROCKS OR STONES LARGER THAN 6 INCHESIN DIAMETER SHALL BE ALLOWED IN ANY BACKFILL. MATERIAL FOR BACKFILLMAY BE MATERIAL RESULTING FROM EXCAVATION, IF SUITABLE IN THEOPINION OF THE ENGINEER.3. A COMPACTION TEST SHALL BE REQUIRED IN (3) RANDOM LOCATIONS AT THESUB-BASE OF ALL WALL FOOTINGS PRIOR TO FOOTING CONCRETEPLACEMENT. COMPACT SOIL TO MINIMUM 95% STANDARD DENSITY INACCORDANCE WITH ASTM D-1557 DOWN TO 2'-0" BELOW ALLFOOTINGS. RE-COMPACT AS NECESSARY UNTIL ACCEPTABLE DENSITYIS ACHIEVED.4. FILL SHALL BE PLACED IN NO DEEPER THAN 10" LOOSE LIFTS, THENMECHANICALLY COMPACTED TO 95% STD. PROCTOR DENSITY. START NOSUBSEQUENT LIFTS UNTIL THE ENTIRE LIFT IS FULLY INSTALLED ANDCOMPACTED.5. A COMPACTION TEST SHALL BE REQUIRED IN (3) RANDOM LOCATIONS ONEVERY 3RD FILL LIFT IN THE SLAB AREA PRIOR TO INSTALLATION OF ANYSUBSEQUENT LIFTS, AS WELL AS THE FINAL LIFT BENEATH THE SLAB(S).COMPACT SOIL TO MINIMUM 95% STANDARD DENSITY INACCORDANCE WITH ASTM D-1557 DOWN TO 2'-0" BELOW ALL SLABS.RE-COMPACT AS NECESSARY UNTIL ACCEPTABLE DENSITY IS ACHIEVED.6. BRACE OR BACKFILL ALL POURED FOUNDATIONS PRIOR TO INSTALLATION OFBUILDING'S STRUCTURAL FILL. REMOVE BACKFILL ONLY AFTER INTERIORSLAB(S) ARE POURED AND ALLOWED TO CURE (MINIMUM 14 DAYS). FILL REQUIREMENTS (IF NECESSARY): EXISTING BUILDING SLAB &N FOUNDATION EXISTING BUILDING SLAB &N FOUNDATION EXISTING BUILDING SLAB &N FOUNDATIONEXISTING BUILDING SLAB &N FOUNDATION EXISTING BUILDING SLAB &N FOUNDATION DS-201 DS-201 SIMPSON®"HDU8" EACH EXT.OUTSIDE CORNER TYPICAL8" X 8" SIDEWALK TURNDOWN REINF. W/(1) #5 CONT. TYP. ALL SIDEWALKS. BS-202 BS-202 NOTE: DO NOT SCALE THESE DRAWINGS. SEEARCHITECTS DRAWINGS FOR ALL CRITICALDIMENSIONS. CONTRACTOR SHALL BE RESPONSIBLETO INDEPENDENTLY VERIFY ALL EXISTING AND NEWDIMENSIONS, AND SHALL BE SOLELY RESPONSIBLE TOSTABILIZE AND BRACE ALL AREAS PRIOR TO ANYDEMOLITION AND/OR CONSTRUCTION. 4" TH. CONCRETE SLABREINFORCED WITH 6" X 6" - 10/10W.W.F. ON 6 MIL VAPOR BARRIERATOP TERMITE TREATED SOIL.3 12" METAL SCREED-KEYCONTROL JOINTS OR SAW CUTJOINTS WITHIN 24 HRS. TYPICAL. Page 35 of 55 WREVISIONS BY DATELACOMBEENGINEERINGMICHAEL S. LACOMBE, P.E.CIVIL / STRUCTURAL(843) 298-0368 / LACOMBE.PE@GMAIL.COM ENGINEERING 12345678910111213141516171819202122232425262728 123456789101112131415161718192021222324252627282930 2930 DRAWN BY:DATE:CHECKED BY:PROJECT #:SCALE:S26041SHOWNMSL06/05/2026 MSLADDITION AND REMODEL:HILTON HEAD ISLAND, SCGOLF CLUBHOUSESPANISH WELLS1 BRAMS POINT ROADSECTIONSS-202ATOVERHANGS(3) #5'S EACH WAY TYP.12" S-202SCALE: 1"=1'-0"SECTION "B-B" #5 X 12" L. DOWELS 32" O.C. DRILL 6"INTO FOUND. WALL. TIE TO #5 CONT.BAR TYP. ALL SIDEWALKS.6 X 6 10-10WWF TYP.4" TH. CONC. SLAB16"20"FOOTING / HAUNCH - POURMONOLITHIC WITH SLAB TYPICAL.8"8"34" X 14" ANCHOR BOLTS 32" O.C. TYP. EXT. WALLS.24" SQ. FTG.4" TH.CONC. SLAB(1) #5 CONT. ATSIDEWALK HAUNCH TYP.MIN. 2" BFF(OR AS REQ'D PER ARCH. PLAN)COMPACTED SOILCOMPACTED SOIL (1) SIMPSON® "CS16" STRAP @ 24" LONGAT EVERY OTHER STUD, HEADER AND / ORCRIPPLE LOCATION TYPICAL AS SHOWN. 2 X 8 SYP ROOF RAFTERS 16" O.C.TYP.1532" APA RATED CDX PLYWOOD ROOF SHEATHING (SEE NAILING SCHEDULE). SEE ARCHITECTURALPLAN FOR RAKE/TRIM& SOFFIT DETAILS2 X 6 SYP WALL STUDS 16" O.C.TYP. SIMPSON® "H2.5A" RAFTERTIE TYPICAL ALL RAFTERS612SIMPSON® "H2.5A" RAFTERTIE TYPICAL ALL RAFTERSS.S. METAL ROOFING (SEE ARCH. PLAN) 8 X 8 (NOM.) P.T. SYP SOLIDPOST TYP.SIMPSON® "CB88" POSTANCHOR CAST INTO CONCRETETYP. EACH POST.DECORATIVE ACCENT(SEE ARCH. PLAN). 2 X 10 (NOM.) CLG. JOISTS 16" O.C. 16"20"8"8"4" TH. CONC. SIDEWALKCOMPACTED SOILS-202SCALE: 1"=1'-0"SECTION "A-A"8"8"COMPACTED SOIL#5 X 12" L. DOWELS 32" O.C. DRILL 6"INTO FOUND. WALL. TIE TO #5 CONT.BAR TYP. ALL SIDEWALKS.34" X 14" ANCHOR BOLTS 32" O.C. TYP. EXT. WALLS. 2 X 6 SYP WALL STUDS 16" O.C.TYP.2 X 6 PURLINS TYP. AT SHEATHING EDGES WHEREEXPOSED (SEE SHEAR NOTES SHEET S-100).SEE ARCHITECTURAL PLAN FORRAKE/TRIM & SOFFIT DETAILS2 X 6 (NOM.) SOFFIT JOISTS 16" O.C. (2) #5 BARS CONTINUOUS IN ALLNEW HAUNCH / FOOTINGS TYPICAL.(2) #5 BARS CONTINUOUS IN ALLNEW HAUNCH / FOOTINGS TYPICAL.(1) #5 BAR CONTINUOUS IN ALLSIDEWALK HAUNCHES TYP. 2 X 8 SYP ROOF RAFTERS 16" O.C.TYP.1532" APA RATED CDX PLYWOOD ROOF SHEATHING (SEE NAILING SCHEDULE).612SIMPSON® "H2.5A" RAFTERTIE TYPICAL ALL RAFTERSS.S. METAL ROOFING (SEE ARCH. PLAN)2 X 10 (NOM.) CLG. JOISTS 16" O.C.SEE ARCH. PLANBLOCKING AS NECC. MATCHEXISTING FIN. FLOORSLOPE MIN. 18" PER FT.SLOPE MIN. 18" PER FT.6 X 6 10-10WWF TYP.IMPERMEABLE V.B. BEHIND ALL FACE-BRICKWAINSCOTS TYP.IMPERMEABLE V.B. BEHIND ALL FACE-BRICKWAINSCOTS TYP.SEE ARCH. PLAN FOR ALL SIDING AND TRIM TYP. BS-201 BS-2012 X 6 PURLINS TYP. AT SHEATHING EDGES WHEREEXPOSED (SEE SHEAR NOTES SHEET S-100). SIMPSON® "BC8" AT EACH POST CAP TYP.SIMPSON® "LUS26" HANGER TYPICALALL SOFFIT JOISTS TO CLEATS Page 36 of 55 WREVISIONS BY DATELACOMBEENGINEERINGMICHAEL S. LACOMBE, P.E.CIVIL / STRUCTURAL(843) 298-0368 / LACOMBE.PE@GMAIL.COM ENGINEERING 12345678910111213141516171819202122232425262728 123456789101112131415161718192021222324252627282930 2930 DRAWN BY:DATE:CHECKED BY:PROJECT #:SCALE:S26041SHOWNMSL06/05/2026 MSLADDITION AND REMODEL:HILTON HEAD ISLAND, SCGOLF CLUBHOUSESPANISH WELLS1 BRAMS POINT ROADFOUNDATIONS-201SECTIONS ANDDETAILS (3) #5'S EACH WAY TYP.12"S-201SCALE: 1"=1'-0"SECTION "B-B" #5 X 12" L. DOWELS 32" O.C. DRILL 6"INTO FOUND. WALL. TIE TO #5 CONT.BAR TYP. ALL SIDEWALKS.6 X 6 10-10WWF TYP.16"20"FOOTING / HAUNCH - POURMONOLITHIC WITH SLAB TYPICAL.8"8"34" X 14" ANCHOR BOLTS 32" O.C. TYP. EXT. WALLS.24" SQ. FTG.4" TH.CONC. SLAB(1) #5 CONT. ATSIDEWALK HAUNCH TYP.MIN. 2" BFF(OR AS REQ'D PER ARCH. PLAN)COMPACTED SOILCOMPACTED SOILSIMPSON® "CB88" POSTANCHOR CAST INTO CONCRETETYP. EACH POST.(2) #5 BARS CONTINUOUS IN ALLNEW HAUNCH / FOOTINGS TYPICAL.SLOPE MIN. 18" PER FT.6 X 6 10-10WWF TYP.8"8"#5 X 12" L. DOWELS 32" O.C. DRILL 6" INTO EXISTING FOUNDATIONAND EPOXY PER CONCRETE NOTE 5. TIE TO CONT. #5 BAR TYP. ALLABUTTING SLABS. LAP BAR PER CONCRETE NOTE 4 (TENSION LAP).S-201SCALE: 3"=1'-0"SECTION "B-B"EXISTINGBUILDINGFOOTING4" TH. CONC. SLABIF QUEEN SIZED BRICKS USED, SAW-CUT ASSHOWN FOR 12" (MIN.) AIR GAP TO POST.P.T. SYP SOLID 8 X 8 (NOM.) POSTSANCHORED TO FOUNDATION AS SHOWN INSECTION DETAILS TYPICAL. 3"(MIN.)36"12"3" (MIN.)S-201SCALE: 1"=1'-0"SECTION "E-E" (4) #5 REBARS EACH WAY AT36" SQUARE FOOTINGS INTERNAL FOOTING SLAB CUTTING AND INSTALLATION NOTES:1.SAW-CUT EXISTING 4" THICK CONCRETE FLOOR SLAB W/ ABRASIVE OR DIAMOND CUTTING WHEEL TO DIMENSIONS AND DEPTH REQUIRED. USE WATERSPRAY TO MITIGATE CONCRETE DUST. ALWAYS WEAR A RESPIRATOR WHEN CUTTING CONCRETE.2.REMOVE CONCRETE FOR NEW FOOTING LOCATION WITH CHIPPING HAMMER IF NECC. AND DISCARD. CAREFULLY EXCAVATE SOIL TO DEPTH REQUIREDTAKING CARE NOT TO DISTURB THE NEW FOOTING BASE GRADE. DO NOT ADD NEW SOIL.3.VERIFY SOILS AT BASE OF NEW FOOTING ARE NOT DISTURBED. COMPACT SOIL AND TEST FOR COMPACTION IF REQUIRED, OR DEEPEN NEW FOOTINGUNTIL NO DISTURBED SOIL IS ENCOUNTERED.4.CAREFULLY DRILL EXISTING SLAB WITH A 78"Ø ROTARY PERCUSSION DRILL 6" DEEP AT MID-DEPTH OF EXISTING SLAB FOR INSERTION OF 12" LONG REBARDOWELS SHOWN OR SPECIFIED.5.CLEAN, BLOW-OUT AND DRY HOLES FULLY AND APPLY EPOXY PER CONCRETE NOTE 5. INSERT REBAR DOWELS INTO EPOXIED HOLES AND ALLOW TO DRYFULLY UNDISTURBED PER THE EPOXY MANUFACTURER'S INSTRUCTIONS.6.INSERT REBAR REINFORCING MAT SHOWN AND/OR SPECIFIED AND ELEVATE WITH PRE-MANUFACTURED REBAR BOLSTERS. INSPECT AND GARNERAPPROVAL PRIOR TO CONCRETE PLACEMENT.7.CAREFULLY INSTALL 3,000 PSI CONCRETE USING PUMP OR WHEELBARROW AND CONSOLIDATE MANUALLY OR WITH VIBRATOR. SCREED THEN TROWELSURFACE FLAT AND FLUSH.8.ALLOW TO HARDEN MINIMUM 14 DAYS PRIOR TO IMPOSITION OF ANY LOADING. UNDISTURBED ORIGINAL SOILNEW 12" THICK, 3,000 PSI CONC.SPREAD FOOTING.(3) #5 DOWELS EACH SIDE OFNEW FOOTING TYP.4" THICK (ASSUMED) EXISTINGCONCRETE FLOOR SLAB.NEW WOOD WALL FRAMING (SEEFRAMING PLAN). MIN. 12" AIR GAP TYP. 2 X 8 LOWER CANOPY RAFTERUNDER-CANOPY CLG.TREATMENT (PER ARCH. PLAN)BEAM 8CANOPY GABLE ENCLOSUREBEYOND (SEE ARCH. PLAN)SIMPSON® "BC8" AT EACH POST CAP TYP. (3) #5 REBARS CONT. THROUGHFOOTINGS AND GRADE BEAMS TYP.S-201SCALE: 1"=1'-0"SECTION "C-C"(3) #5 REBAR DOWELS WITHIN GRADE BEAMS AT LOCATIONSSHOWN. DRILL 6" INTO EXISTING FOUND. EPOXY PERCONCRETE NOTE 5. TIE TO #5 CONT. BAR AT TRANSVERSEFOOTINGS. NOTE: ADJUST GRADE BEAM DEPTH AS NECC.AFTER EXISTING HAUNCH DEPTH IS DETERMINED. EXISTING EXT. STUDWALL & SHEATHING TYP. (ASSUMED)EXISTING SOIL GRADEEXISTING DECK FRAMING (ASSUMED)EXISTING DECK FRAMING (ASSUMED)EXISTINGFOOTINGOR CMUFOUND.WALL12"24"(3) COURSES OF 12" X 12" CMUBLOCK TYP. EACH PORCH POST.FILL W/ 3,000 PSI CONC. TYP.SIMPSON® HPA28 ANCHOR. EMBED16" INTO CMU PIER BLOCKS ANDCAST INTO CONCRETE TYP. EACHSIDE OF ALL PORCH POSTS.CUT & WRAP POSTS W/ QUEEN SIZEBRICKS. STYLE PER ARCH. PLANEXISTING CLAP SIDING(SEE ARCH. PLAN) BS-201 BS-201 SEE ARCHITECTURAL PLAN FORMORTAR JOINT TYPE TYPICAL.CORRUGATED GALV. MASONRY TIES EVERYOTHER COURSE (MAX.). ATTACH W/ CAMO®#8 X 1-58" DECK SCREWS (OR EQ.) TYP.11 58"SQUARE S-201SCALE: 1"=1'-0"SECTION "D-D"24"12"GRADE BEAM(3) #5 REBARS CONTINUOUSGRADE BEAM ELEV.COMPACTED SOILSOIL GRADE LINESEE ARCH. PLANMATCH EXISTING HOMEFOUNDATION ELEVATION Page 37 of 55 WREVISIONS BY DATELACOMBEENGINEERINGMICHAEL S. LACOMBE, P.E.CIVIL / STRUCTURAL(843) 298-0368 / LACOMBE.PE@GMAIL.COM ENGINEERING 12345678910111213141516171819202122232425262728 123456789101112131415161718192021222324252627282930 2930 DRAWN BY:DATE:CHECKED BY:PROJECT #:SCALE:S26041SHOWNMSL06/05/2026 MSLADDITION AND REMODEL:HILTON HEAD ISLAND, SCGOLF CLUBHOUSESPANISH WELLS1 BRAMS POINT ROADFLOOR PLANS-300ANDBEAMS PLAN AS-302 AS-302 AS-301 AS-301 BEAM 1BEAM 2BEAM 2BEAM 1 BEAM 4BEAM 3BEAM 6BEAM 5 BEAM 7BEAM 7 BEAM 7BEAM 7BEAM 7BEAM 7BEAM 7 WALLS AND BEAMS FRAMING PLANSCALE: 14"=1'-0" BEAM 8BEAM 8BEAM 8BEAM 8BEAM 8BEAM 8BEAM 8 BEAM 8 BEAM 8 BEAM 8BEAM 8BEAM 8BEAM 8BEAM 8BEAM 8BEAM 8 BEAM 8BEAM 8 BEAM 8BEAM 8BEAM 8BEAM 8 BEAM 9HEADER H-1 AS-303 AS-303 AS-304 AS-304 BS-303 BS-303 NOTE: DO NOT SCALE ANY PORTION OF THISDRAWING NOT SPECIFICALLY NOTED. SEEARCHITECTS DRAWINGS FOR ALL CRITICALDIMENSIONS. Page 38 of 55 WREVISIONS BY DATELACOMBEENGINEERINGMICHAEL S. LACOMBE, P.E.CIVIL / STRUCTURAL(843) 298-0368 / LACOMBE.PE@GMAIL.COM ENGINEERING 12345678910111213141516171819202122232425262728 123456789101112131415161718192021222324252627282930 2930 DRAWN BY:DATE:CHECKED BY:PROJECT #:SCALE:S26041SHOWNMSL06/05/2026 MSLADDITION AND REMODEL:HILTON HEAD ISLAND, SCGOLF CLUBHOUSESPANISH WELLS1 BRAMS POINT ROADSECTIONS-301THROUGHKITCHEN SIMPSON® "H2.5A" RAFTERTIE TYPICAL ALL RAFTERS SEE ARCHITECTURAL PLAN FORRAKE/TRIM & SOFFIT DETAILS 7'-0" S-301SCALE: 34" =1'-0"SECTION "A-A" 24" LAP (MIN,) 8'-0" CLG. HT TYP. U.N.2 X 6 (NOM.) SYP EXT. WALLSTUDS 16" O.C.TYP.BEAM 7 24" LAP (MIN,) SEE ARCH. PLANBEAM 72 X 8 SYP ROOF RAFTERS 16" O.C.TYP.1532" APA RATED CDX PLYWOOD ROOFSHEATHING (SEE NAILING SCHEDULE).SIMPSON® "H2.5A" RAFTERTIE TYPICAL ALL RAFTERS612S.S. METAL ROOFING(SEE ARCH. PLAN) 1212STORAGE ATTIC KITCHEN AREA OPEN ATTICFOR HVAC ETC. Page 39 of 55 WREVISIONS BY DATELACOMBEENGINEERINGMICHAEL S. LACOMBE, P.E.CIVIL / STRUCTURAL(843) 298-0368 / LACOMBE.PE@GMAIL.COM ENGINEERING 12345678910111213141516171819202122232425262728 123456789101112131415161718192021222324252627282930 2930 DRAWN BY:DATE:CHECKED BY:PROJECT #:SCALE:S26041SHOWNMSL06/05/2026 MSLADDITION AND REMODEL:HILTON HEAD ISLAND, SCGOLF CLUBHOUSESPANISH WELLS1 BRAMS POINT ROADMAINS-303BUILDINGSECTIONS 2 78" FASTENMASTER®"HEADLOK" STRUCTURALFLAT HEAD SCREWSTHESE CONN'S TYP. GLASS PANEL (W/FRAME) HT. TO BE10'-7" (MAXIMUM)DETAIL "3"S-305 S-303SCALE: 14" =1'-0"SECTION "A-A" DETAIL "2"S-305DETAIL "1"S-305BEAM 8 (BEYOND)BEAM 8SEE ARCH. PLAN FOR CLG. TREATMENT TYP.2 X 8 PORCH ROOF RAFTERS 16" O.C. TYP. S-303SCALE: 14" =1'-0"SECTION "B-B" 8' CEILING (BEYOND)BAR SEPARATION WALL (BEYOND)BAR (BEYOND)SIMPSON® "BC8" ATEACH POST CAP TYP. ATTIC FORHVAC ETC.8' CEILING (BEYOND)BAR SEPARATION WALL (BEYOND)BAR (BEYOND) Page 40 of 55 WREVISIONS BY DATELACOMBEENGINEERINGMICHAEL S. LACOMBE, P.E.CIVIL / STRUCTURAL(843) 298-0368 / LACOMBE.PE@GMAIL.COM ENGINEERING 12345678910111213141516171819202122232425262728 123456789101112131415161718192021222324252627282930 2930 DRAWN BY:DATE:CHECKED BY:PROJECT #:SCALE:S26041SHOWNMSL06/05/2026 MSLADDITION AND REMODEL:HILTON HEAD ISLAND, SCGOLF CLUBHOUSESPANISH WELLS1 BRAMS POINT ROADSECTIONS-302THROUGHGOLF SHOP SEE ARCHITECTURAL PLAN FORRAKE/TRIM, SIDING & SOFFIT DETAILS S-302SCALE: 34" =1'-0"SECTION "A-A" S-302SCALE: 1 12" =1'-0"DETAIL "1" 8"8"8"COMPACTED SOILCOMPACTED SOILCOMPACTED SOIL 2 X 10 (NOM.) CLG. JOISTS 16" O.C. DETAIL "1"S-302 C OF ROOML 4" TH. CONC. SIDEWALK#5 X 12" L. DOWELS 32" O.C. DRILL 6"INTO FOUND. WALL. TIE TO #5 CONT.BAR TYP. ALL SIDEWALKS.34" X 14" ANCHOR BOLTS 32" O.C. TYP. EXT. WALLS.SLOPE MIN. 18" PER FT.IMPERMEABLE V.B. BEHIND ALL FACE-BRICKWAINSCOTS TYP. 2 X 8 SYP ROOF RAFTERS 16" O.C.TYP.1532" APA RATED CDX PLYWOOD ROOFSHEATHING (SEE NAILING SCHEDULE).SIMPSON® "H2.5A" RAFTERTIE TYPICAL ALL RAFTERS612 SIMPSON® "LUS28" HANGER EA.FALSE RAFTER TO CLEAT TYP. S.S. METAL ROOFING(SEE ARCH. PLAN) 12122 X 10 SYP RIDGE BOARD TYP. SIMPSON® "LUS26" HANGER EA.SOFFIT JOIST TO CLEAT TYP.8'-0" CLG. HT TYP. U.N.2 X 6 (NOM.) SYP EXT. WALLSTUDS 16" O.C.TYP.2 X 4 (NOM.) SYP INT. WALLSTUDS 16" O.C.TYP.2 X 6 (NOM.) SYP EXT. WALLSTUDS 16" O.C.TYP. 2 X 8 CLEAT TYP.2 X 8 FALSE RAFTERS 16" O.C.TYP. IN PRO SHOP.2 X 8 COLLAR TIES16" O.C. TYP. IN PRO SHOP.4 12" FASTENMASTER® "HEADLOK"STRUCTURAL FLAT HEADSCREWS AS SHOWN THIS CONN.2 78" FASTENMASTER® "HEADLOK"STRUCTURAL FLAT HEAD SCREWSAS SHOWN THIS CONN.2 X 8 UPPER RAFTER2 X 8 LOWER RAFTER1532" APA RATED CDX PLYWOOD ROOFSHEATHING (SEE NAILING SCHEDULE). OPEN ATTICFOR HVAC ETC. PRO SHOP 2 X 4 (NOM.) SUPPORT PONYWALL STUDS 16" O.C.TYP. Page 41 of 55 WREVISIONS BY DATELACOMBEENGINEERINGMICHAEL S. LACOMBE, P.E.CIVIL / STRUCTURAL(843) 298-0368 / LACOMBE.PE@GMAIL.COM ENGINEERING 12345678910111213141516171819202122232425262728 123456789101112131415161718192021222324252627282930 2930 DRAWN BY:DATE:CHECKED BY:PROJECT #:SCALE:S26041SHOWNMSL06/05/2026 MSLADDITION AND REMODEL:HILTON HEAD ISLAND, SCGOLF CLUBHOUSESPANISH WELLS1 BRAMS POINT ROADXS-304ANDDETAILS S-304SCALE: 12" =1'-0"(6) FULL-LENGTH STUDS AT EACH BEARING END. STRAP TO POST (6 STUDS) AT BEAM 2 CONNECTION W/ SIMPSON® CLIP "CCQ96SDS2.5".STRAP TO POST AT ENDS (6 STUDS) W/ (2) SIMPSON® "H6" CLIPS AS SHOWN ON SHEET S-101. FACE MOUNT RAFTERS W/ SIMPSON® "LRU28Z" HANGERS WHERE SHOWN TYP.LEGEND-DENOTES 1ST FLOOR WALLS & PARTITIONS (BELOW).-DENOTES LVL OR OTHERWISE PLIED WOOD JOISTS OR BEAMS.-LAPPED SYP JOIST OR RAFTER OVER WALL (24" LAP MINIMUM) WHERE POSSIBLE.24"(MIN.)-DENOTES MULTI-PLY BEAM W/ PLYWOOD FLITCH PLATES AS SPECIFIED (BELOW).-DENOTES LVL OR OTHERWISE PLIED WOOD JOISTS OR BEAMS (BELOW).-DENOTES SINGLE LVL (TYPICALLY RIM-JOIST OR LONG-SPAN JOISTS OR RAFTERS).-DENOTES PONY WALL BENEATH RAFTERSPOST-DENOTES DBL. 2 X 4 SUPPORT POST TO REMAIN. BEAM 4BEAM 3 SECTION "A-A" 2 X 8 CLG. JOISTS RAISED ABOVE BARFOR VOLUME CLG. (IF DESIRED) TYP.2 X 12 SYP CLG. JOISTS BEYOND BEAM TYP.WALL PILASTER (SEE PLAN) 2 X 4 PARTITION WALL ABOVE BEAMS TYP.INTERIOR WALL(BEYOND)BAR (BEYOND. SEE ARCH. PLAN)BAR SEPARATION WALL (SEE PLAN) KITCHEN AREA BAY (BEYOND)24" LAP TYP. 2 X 8 LOWER CANOPY RAFTER 2 X 8 UPPER CANOPY RAFTER 2 X 8 BUILDING UPPER RAFTER 2 X 8 BUILDING LOWER RAFTERBEAM 1UNDER-CANOPY CLG.TREATMENT (PER ARCH. PLAN)BEAM 8DINING AREA(BEYOND) DESCRIPTIONSTRUCTURAL FRAMING MEMBER SCHEDULEDESIGNATIONCOMMENTSLENGTHDEPTHGRADEBEAM 124F-V8 DF50'-10"VERIFY30"8 34" GLULAM® BEAMBEAM 224F-V8 DF29'-10"VERIFY30"8 34" GLULAM® BEAM SIMPSON® "CCQ96SDS2.5"TYP. AT EACH BEARING ENDBEAM 1SIMPSON® "CCQ96SDS2.5"TYP. AT EACH BEARING END (6) FULL-LENGTH STUDS AT EACH BEARING END. STRAP TO POST (6 STUDS) AT BEAM 2 CONNECTION W/ SIMPSON® CLIP "CCQ96SDS2.5".STRAP TO POST AT ENDS (6 STUDS) W/ (2) SIMPSON® "H6" CLIPS AS SHOWN ON SHEET S-101. FACE MOUNT RAFTERS W/ SIMPSON® "LRU28Z" HANGERS WHERE SHOWN TYP.BEAM 319'-1"18"(3) PLY 1 34" MICROLLAM® LVL'S (OR EQ.)2.0E(4) FULL-LENGTH STUDS AT EACH BEARING END. ANCHOR SUPPORT POST FOR BEAMS 1 & 2 W/ (2) SIMPSON® BRACKETS "LCE4" ASSHOWN ON SHEET S-101. FACE MOUNT CLG. JOISTS W/ SIMPSON® "LUS210" HANGERS WHERE SHOWN TYP.BEAM 419'-7 12"18"(3) PLY 1 34" MICROLLAM® LVL'S (OR EQ.)2.0E(4) FULL-LENGTH STUDS AT EACH BEARING END. ANCHOR SUPPORT POST FOR BEAMS 1 & 2 W/ (2) SIMPSON® BRACKETS "LCE4" ASSHOWN ON SHEET S-101. FACE MOUNT CLG. JOISTS W/ SIMPSON® "LUS210" HANGERS WHERE SHOWN TYP.BEAM 511'-7"18"(2) PLY 1 34" MICROLLAM® LVL'S (OR EQ.)2.0E(4) FULL-LENGTH STUDS AT EACH BEARING END. FACE MOUNT CLG. JOISTS W/ SIMPSON® "LUS210" OR "IUS1.88 /11.88" HANGERS WHEREREQUIRED TYP.BEAM 618'-0"18"(2) PLY 1 34" MICROLLAM® LVL'S (OR EQ.)2.0E(4) FULL-LENGTH STUDS AT EACH BEARING END. ANCHOR SUPPORT POST FOR BEAMS 1 & 2 W/ (2) SIMPSON® BRACKETS "LCE4" ASSHOWN ON SHEET S-101. FACE MOUNT CLG. JOISTS W/ SIMPSON® "LUS210" HANGERS WHERE SHOWN TYP. (2) SIMPSON® "LCE4" CLIPSAT EACH BEARING END TYP. BEAM 7VARIES11 14" (3) PLY 1 34" MICROLLAM® LVL'S (OR EQ.)2.0E(4) FULL-LENGTH STUDS AT EACH BEARING END. FACE MOUNT CLG. JOISTS W/ SIMPSON® "LUS210" HANGERS WHERE SHOWN TYP.BEAM 8VARIES11 14" (4) PLY P.T. 2 X 8 (NOM.) SYP#212" (NOM.) CDX PLYWOOD FLITCH PLATES BETWEEN PLIES. ANCHOR TO POSTS W/ GALV. SIMPSON® "BC8" POST CAPS. LACE ALL OUTSIDECORNERS. CLAD PER ARCHITECTURAL PLAN.BEAM 922'-2"(3) PLY 1 34" MICROLLAM® LVL'S (OR EQ.)2.0E(4) FULL-LENGTH STUDS AT EACH BEARING END. BEAR ON BEAM 8 BELOW. CLAD PER ARCHITECTURAL PLAN IF EXPOSED.11 14" HEADER H-120'-2"(VERIFY)BLOCK & STRAP AS REQ'D. (3) JACKS & (2) KING STUDS EA. END TYP. VERIFY OPENING PER GLASS-WALL UNIT PER MFR.(3) PLY 1 34" MICROLLAM® LVL'S (OR EQ.)2.0E18" CANOPY GABLE ENCLOSURE(PER ARCH. PLAN)SIMPSON® "BC8" ATEACH POST CAP TYP. ATTIC FORHVAC ETC.2 X 8 BUILDING UPPER RAFTER 2 X 8 BUILDING LOWER RAFTER (3) #5 REBARS CONT.THROUGH FOOTINGS ANDGRADE BEAMS TYP. 1012612 2121012 Page 42 of 55 2 X 8 LOWER RAFTER WREVISIONS BY DATELACOMBEENGINEERINGMICHAEL S. LACOMBE, P.E.CIVIL / STRUCTURAL(843) 298-0368 / LACOMBE.PE@GMAIL.COM ENGINEERING 12345678910111213141516171819202122232425262728 123456789101112131415161718192021222324252627282930 2930 DRAWN BY:DATE:CHECKED BY:PROJECT #:SCALE:S26041SHOWNMSL06/05/2026 MSLADDITION AND REMODEL:HILTON HEAD ISLAND, SCGOLF CLUBHOUSESPANISH WELLS1 BRAMS POINT ROADDETAILSS-305ANDSECTIONS SCALE: 1" =1'-0"DETAIL "2"SCALE: 1" =1'-0"DETAIL "1"2 X 8 SHED DORMER RAFTER 2 X 8 UPPERRAFTER2 78" FASTENMASTER® "HEADLOK"STRUCTURAL FLAT HEAD SCREWS ASSHOWN THIS CONN. (FROM BOTH SIDES).1532" APA RATED CDX PLYWOOD ROOFSHEATHING (SEE NAILING SCHEDULE).S.S. METAL ROOFING(SEE ARCH. PLAN) SIMPSON® "H2.5A" RAFTERTIE TYPICAL ALL RAFTERS 2" (HOLD)2" (HOLD)TYPICAL MULTI-PLY & COMPOSITE BEAM FASTENING DETAIL16" (TYP.) NOT TO SCALE 5" LONG FASTENMASTER® "HEADLOK" OR "LEDGERLOK"SCREWS 16" O.C. TOP & BOTTOM TYP. KEEP 2" AWAYFROM EDGES TYP. ALL BEAMS. NOTE: SOME OBJECTS SHOWNOVERSIZED FOR CLARITY MICROLAM® LVL'S TYP. HEADER H-1GLASS PANEL SYSTEM (SEE MFR.). (3) PLY 2 X 8 (NOM. HEADER W/ 12" PLYWOOD FLITCH PLATES TYP. OVERCLERESTORY WINDOWS.NOTE: 2 X 6 JAMBS & KINGSBETWEEN WINDOW UNITS REQ'D. BEAM 9 (FULLY CLAD &SEALED WATERTIGHT).ENTRY PORCH RIDGESPECIAL CUT BEAM -SEE DETAILDETAIL "4"S-304 SCALE: 1" =1'-0"DETAIL "3" S-305SCALE: 3" =1'-0"DETAIL "4" 2" (HOLD)16" (TYP.)32" O.C. (MIDLINE TYP.)2" (HOLD) 2 X 8 LOWER RAFTERENTRY PORCH RIDGE24"CUT LVL'S TO FIT RAFTERS BELOW. BEVELED LVL'STO REST ON TRIPLE LVL RAFTERS AT BEARING ENDS.ATTACH W/ (3) 5" LONG "HEADLOK" SCREWSTOE-NAILED TO RAFTERS TYP. (4) LOCATIONS.S.S. METAL ROOFING(SEE ARCH. PLAN)1532" APA RATED CDX PLYWOOD ROOFSHEATHING (SEE NAILING SCHEDULE). (3) PLY 2 X 8 (NOM. HEADER W/ 12" PLYWOOD FLITCH PLATESTYP. OVER CLERESTORY WINDOWS.NOTE: 2 X 6 JAMBS & KINGS BETWEEN WINDOW UNITS REQ'D. FIXED-GLASS WINDOW SYSTEM (SEE MFR.). SIMPSON® "LRU28Z" HANGER EA.RAFTER TO CLEAT TYP. 5" LONG FASTENMASTER® FLAT"HEADLOK" SCREWS IN PATTERNSPECIFIED THIS SHEET TYP.DOUBLE 2 X 6 SILL TYP. SIMPSON® "LRU28Z" HANGER EA.RAFTER TO CLEAT TYP.FIXED-GLASS WINDOW SYSTEM (SEE MFR.). SIMPSON® "LRU28Z" HANGER EA.RAFTER TO CLEAT TYP. (BEAMS 14" DEEP OR GREATER)(BEAMS LESS THAN 14" DEEP)MICROLAM® LVL'S TYP.SYP 2 X 8'S (NOM.)1 12" (HOLD)12" (NOM.)PLYWOOD FLITCHPLATES2" (HOLD)(BEAMS 14" DEEP OR GREATER)(BEAMS LESS THAN 14" DEEP) MICROLAM® LVL'S TYP. 5" LONG FASTENMASTER® "HEADLOK" OR "LEDGERLOK"SCREWS 16" O.C. TOP & BOTTOM TYP. KEEP 2" AWAYFROM EDGES TYP. ALL BEAMS. S-305S-305S-305 2 X 8 SHED DORMER RAFTER 2 X 8 CANOPY RAFTER 2 X 8 OVERHANG3122123121012 212 612 612 S.S. METAL ROOFING(SEE ARCH. PLAN)1532" APA RATED CDX PLYWOOD ROOFSHEATHING (SEE NAILING SCHEDULE).S.S. METAL ROOFING(SEE ARCH. PLAN)1532" APA RATED CDX PLYWOOD ROOFSHEATHING (SEE NAILING SCHEDULE). Page 43 of 55 WREVISIONS BY DATELACOMBEENGINEERINGMICHAEL S. LACOMBE, P.E.CIVIL / STRUCTURAL(843) 298-0368 / LACOMBE.PE@GMAIL.COM ENGINEERING 12345678910111213141516171819202122232425262728 123456789101112131415161718192021222324252627282930 2930 DRAWN BY:DATE:CHECKED BY:PROJECT #:SCALE:S26041SHOWNMSL06/05/2026 MSLADDITION AND REMODEL:HILTON HEAD ISLAND, SCGOLF CLUBHOUSESPANISH WELLS1 BRAMS POINT ROADCEILINGSS-400JOISTSPLAN AS-302 AS-301 AS-301 BEAM 4BEAM 3BEAM 6BEAM 5 AS-302 LIFT BEAM 1 (ABOVE)BEAM 2 (ABOVE)BEAM 2 (ABOVE)BEAM 1 (ABOVE)NOTE: CEILING MAY BE RAISED ABOVEBAR AREA FOR VOLUME CLG. IF DESIRED.OPEN TO ROOF PONY WALL(ABOVE)BEAM 7BEAM 7 BEAM 7BEAM 7BEAM 7BEAM 7BEAM 7PONY WALL(ABOVE)PONY WALL(ABOVE) 11 78" DEEP TJI® 11O'S16" O.C. THIS AREA 24" LAP TYP. POST AS-304 AS-304 DOUBLE CLG. JOIST FOR ROOFVALLEY SUPPORT ABOVE TYP.DOUBLE CLG. JOISTS FORROOF VALLEY SUPPORTPOST ABOVE TYP. NOTE: DO NOT SCALE ANY PORTION OF THISDRAWING NOT SPECIFICALLY NOTED. SEEARCHITECTS DRAWINGS FOR ALL CRITICALDIMENSIONS.CEILING FRAMING PLANSCALE: 14"=1'-0" COFFERED CLG.COFFERED CLG. Page 44 of 55 WREVISIONS BY DATELACOMBEENGINEERINGMICHAEL S. LACOMBE, P.E.CIVIL / STRUCTURAL(843) 298-0368 / LACOMBE.PE@GMAIL.COM ENGINEERING 12345678910111213141516171819202122232425262728 123456789101112131415161718192021222324252627282930 2930 DRAWN BY:DATE:CHECKED BY:PROJECT #:SCALE:S26041SHOWNMSL06/05/2026 MSLADDITION AND REMODEL:HILTON HEAD ISLAND, SCGOLF CLUBHOUSESPANISH WELLS1 BRAMS POINT ROADDETAILS LACOMBEENGINEERINGENGINEERING 123456789101112131415161718192021222324252627282930DRAWN BY:DATE:CHECKED BY:PROJECT #:SCALE:S26041SHOWNMSL06/05/2026 MSLADDITION AND REMODEL:HILTON HEAD ISLAND, SCGOLF CLUBHOUSESPANISH WELLS1 BRAMS POINT ROADROOF FRAMINGS-500PLAN ANDDETAILSROOF FRAMING PLANSCALE: 14"=1'-0" ROOF FRAMING NOTES:1. ROOF RAFTERS TO BE #2 GRADE 2 X 8 (NOM.) SYP MEMBERS SPACED 16" O.C.UNLESS NOTED ON THIS SHEET (NOTE LVL'S FOR LONG SPANS).2. INSTALL ALL CLIPS, STRAPS HOLD-DOWNS & TIES ETC. AS SHOWN OR DESCRIBED INTHESE DRAWINGS. ALL SUCH DEVICES SHALL BE INSTALLED PER THEMANUFACTURER'S INSTRUCTIONS AND SHALL INCLUDE ALL MANUFACTURER PROVIDEDAND / OR SPECIFIED FASTENERS. COFFER ALL RIDGES PER IRC CODE (13 RULE).CONSULT W/ ENGINEER WHERE VAULTED CEILING IS REQ'D.3. ALL HIPS, RIDGES AND VALLEYS SHALL BE MINIMUM #2 GRADE 2 X 10 (NOM.) SYPMEMBERS. NO SPLICING SHALL BE ALLOWED WITHOUT FULL AND CONTINUOUSSUPPORT BENEATH THAT SPLICE.4. FRAMING CONTRACTOR IS RESPONSIBLE TO PROVIDE AND INSTALL ALL TEMPORARYBRACING, AND SHALL NOT REMOVE BRACING UNTIL ALL SUPPORT ELEMENTS ARESECURELY FASTENED AND PREPARED TO ACCEPT THE FULL DEAD AND LIVE LOADSIMPOSED.5.DO NOT OVER-CUT BIRDS-MOUTHS. DO NOT TOE-NAIL RAFTERS AT BIRDS-MOUTHSAND AVOID EXCESSIVE NAILING OF ANY MEMBER, AS IT WILL DEGRADE THECONNECTION. PROVIDE FULL-SEATED CUTS AT WALL PLATES, BUT DO NOT CUT BIRDSMOUTHS GREATER THAN 13 RAFTER DEPTH.6.ROOF SHEATHING SHALL BE MINIMUM 1532" STRUCTURAL 1 GRADE CDX PLYWOOD.OSB PLYWOOD SHALL NOT BE USED.7.BREAK SUB-FASCIA BUTT-SPLICES ONLY ON CENTERLINES OF RAFTER END LOCATIONS.DO NOT SPLICE SUB-FASCIA BOARDS SHORTER THAN 48".8.ALL FIREPLACES AND CHIMNEYS TO BE CONSTRUCTED AND INSTALLED IN FULLCOMPLIANCE WITH INTERNATIONAL RESIDENTIAL CODE 2021 CHAPTERS 3, 10 AND18.1.9.ALL MEMBERS OUTSIDE BUILDING ENVELOPE TO BE PRESSURE TREATED AS REQUIRED.NOTE: SUPPORT RAFTERSBENEATH CLERESTORY WALLSTO BE (3) PLY 7 14"MICROLLAM LVL'S TYP.2 X 10 (NOM.) COLLAR TIES / JOISTS TYP. (BELOW) LEGEND-DENOTES WALLS (BELOW).POST-DENOTES DBL. 2 X 4 SUPPORT POSTTO REMAIN.-DENOTES PONY WALL BENEATH RAFTERSNOTE: DO NOT SCALE ANY PORTION OF THISDRAWING NOT SPECIFICALLY NOTED. SEEARCHITECTS DRAWINGS FOR ALL CRITICALDIMENSIONS.SEE ARCH. PLAN FOR ALLOVERHANGS TYPICAL FLY RAFTERS. SEE DETAILSHEET S-100 -DENOTES BEAMS (BELOW). RIDGE RIDGE RIDGE HIPHIP HIPHIP VALLEY VALLEY VALLEY VALLEYRIDGE VALLEYVALLEY VALLEYVALLEY HIP HIP HIP HIP 6:126:126:12 6:126:126:126:126:126:126:126:12 6:12 6:12 3:123:123:12 3:123:12 3:12 3:123:126:126:12 6:126:12 3:123:123:12 10:1210:12RIDGE 12:1212:1212:1212:1212:1212:1212:1212:126:126:126:126:126:12 2:122:122:122:122:122:123:123:12 6:126:12 6:12 6:126:12 6:12 12:1212:1212:1212:12NOTE: SUPPORT RAFTERSBENEATH CLERESTORY WALLS TOBE (3) PLY 7 14" MICROLLAM LVL'STYP. 10:1210:12 10:1210:1210:1210:1210:1210:12 SEE ARCH. PLAN FOR ALLOVERHANGS TYPICAL SEE ARCH. PLAN FOR ALLOVERHANGS TYPICALSEE ARCH. PLAN FOR ALLOVERHANGS TYPICALSEE ARCH. PLAN FOR ALLOVERHANGS TYPICAL AS-302 AS-302 AS-301 AS-301 AS-304 AS-304 Page 45 of 55 DESIGNDRAFTCONSULTCONSTRUCTSPANISH WELLBRAMS POINT ROAD,HILTON HEAD, SOUTH CAROLINA XXXXXXXXXXXXXXXPERMITRMYRMY08-11-2026AS SHOWN2653-MS-E1SPANISH WELLS PLANTATION ' Page 46 of 55 DESIGNDRAFTCONSULTCONSTRUCTSPANISH WELLBRAMS POINT ROAD,HILTON HEAD, SOUTH CAROLINA XXXXXXXXXXXXXXXPERMITRMYRMY08-11-2026AS SHOWN2653-MS-E1SPANISH WELLS PLANTATION ' Page 47 of 55 DESIGNDRAFTCONSULTCONSTRUCTSPANISH WELLBRAMS POINT ROAD,HILTON HEAD, SOUTH CAROLINA XXXXXXXXXXXXXXXPERMITRMYRMY08-11-2026AS SHOWN2653-MS-E1SPANISH WELLS PLANTATION ' Page 48 of 55 DESIGNDRAFTCONSULTCONSTRUCTSPANISH WELLBRAMS POINT ROAD,HILTON HEAD, SOUTH CAROLINA XXXXXXXXXXXXXXXPERMITRMYRMY08-11-2026AS SHOWN2653-MS-E1SPANISH WELLS PLANTATION ' Page 49 of 55 Page 50 of 55 Page 51 of 55 Page 52 of 55 1 DESIGN TEAM/DRB COMMENT S H E E T The comments below are staff recommendations to the Design Review Board (DRB) and do NOT constitute DRB approval or denial. PROJECT NAME: Spanish Wells Clubhouse Addition DRB#: DRB-000872-2026 DATE: 09/23/2026 CATEGORY: Alteration/Addition RECOMMENDATION: Approval ☐ Approval with Conditions ☐ Denial ☐ APPLICATION MATERIAL DRB REQUIREMENTS Complies Yes No Not Applicable Comments or Conditions Demolition Plan if needed ☐ ☐ ☒ Existing Conditions match As-Built ☐ ☐ ☒ Dimensioned Details and of Sections ☒ ☐ ☐ Detail Illustrating Connection to Existing Structure ☒ ☐ ☐ New Building Details Match Existing Building Details ☒ ☐ ☐ ARCHITECTURAL DESIGN DESIGN GUIDE/LMO CRITERIA Complies Yes No Not Applicable Comments or Conditions Structure is designed to be appropriate to the neighborhood ☒ ☐ ☐ Promotes pedestrian scale and circulation ☒ ☐ ☐ Design is unobtrusive and set into the natural environment ☒ ☐ ☐ Utilizes natural materials and colors ☒ ☐ ☐ Avoids distinctive vernacular styles ☒ ☐ ☐ Design is appropriate for its use ☒ ☐ ☐ All facades shall have equal design characteristics ☒ ☐ ☐ Avoids monotonous planes or unrelieved repetition ☒ ☐ ☐ Has a strong roof form with enough variety to provide visual interest ☒ ☐ ☐ Page 53 of 55 2 Overhangs are sufficient for the façade height ☒ ☐ ☐ Forms and details are sufficient to reduce the mass of the structure ☒ ☐ ☐ Human scale is achieved by the use of proper proportions and architectural elements ☒ ☐ ☐ Utilizes a variety of materials, textures, and colors ☒ ☐ ☐ Using the same materials and colors as the existing building; color board needs to be provided Incorporates wood or wood simulating materials ☒ ☐ ☐ Windows are in proportion to the façade ☒ ☐ ☐ Details are clean, simple, and appropriate while avoiding excessive ornamentation ☒ ☐ ☐ Utilities and equipment are concealed from view ☒ ☐ ☐ Decorative lighting is limited and low wattage and adds to the visual character ☒ ☐ ☐ Accessory elements are designed to coordinate with the primary structure ☒ ☐ ☐ LANDSCAPE DESIGN DESIGN GUIDE/LMO CRITERIA Complies Yes No Not Applicable Comments or Conditions Treats the Landscape as a major element of the project ☒ ☐ ☐ Provides Landscaping of a scope and size that is in proportion to the scale of the development ☒ ☐ ☐ Landscape is designed so that it may be maintained in its natural shape and size ☒ ☐ ☐ Preserves a variety of existing native trees and shrubs ☒ ☐ ☐ Provides for a harmonious setting for the site’s structures, parking areas or other construction ☒ ☐ ☐ Location of existing trees and new trees provides street buffers, mitigation for parking lots, and an architectural complement that visually mitigates between parking lots and building(s) ☒ ☐ ☐ Shrubs are selected to complement the natural setting, provide visual interest and screen less-desirable elements of the project ☒ ☐ ☐ A variety of species is selected for texture and color ☒ ☐ ☐ Provides overall order and continuity of the landscape plan ☒ ☐ ☐ Native plants or plants that have historically been prevalent on the Island are utilized ☒ ☐ ☐ A variety of sizes is selected to create a “layered” appearance for visual interest and a sense of depth ☒ ☐ ☐ The location of existing mature trees is taken into account in placement of shrubs so as to not damage tree ☒ ☐ ☐ Page 54 of 55 3 roots Proper spacing and location for plants to reach their mature size and natural shape while avoiding excessive or unnatural pruning ☒ ☐ ☐ Proposed groundcovers are evergreen species with low maintenance needs ☒ ☐ ☐ Large, grassed lawn areas encompassing a major portion of the site are avoided ☒ ☐ ☐ The adjacent development is taken into account in determining the most appropriate buffer so as not to depart too dramatically from the neighborhood ☒ ☐ ☐ Ornamentals and annuals are limited to entrances and other focal points ☒ ☐ ☐ NATURAL RESOURCE PROTECTION DESIGN GUIDE/LMO CRITERIA Complies Yes No Not Applicable Comments or Conditions An effort has been made to preserve existing trees and under story plants ☒ ☐ ☐ Supplemental and replacement trees meet LMO requirements for size, species and number ☒ ☐ ☐ Wetlands if present are avoided and the required buffers are maintained ☒ ☐ ☐ Sand dunes if present are not disturbed ☐ ☐ ☒ COMMENTS & CONDITIONS 1. Staff recommends approval with conditions: a. Physical color board be provided. b. Other plan reviews submitted (Minor Development Plan Review) Page 55 of 55

Source: Town of Hilton Head Island website. First collected Oct 13, 2026.