RecordWell Data

Design Review Board Meeting — Agenda Packet

Town of Hilton Head Island · Beaufort County · Design Review Board · meeting of Aug 26, 2026 · Agenda packets

Open the original document More from Town of Hilton Head Island

Text

Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.

Town of Hilton Head Island Design Review Board Meeting Wednesday, August 26, 2026, 2:30 PM 1 Town Center Court, Hilton Head Island, SC Benjamin M. Racusin Council Chambers The Design Review Board meeting will be held in person at Town Hall in the Benjamin M. Racusin Council Chambers. 1. Call to Order 2. Adoption of the Agenda 3. Approval of the Minutes a. Regular Meeting Minutes of August 12, 2026 4. Unfinished Business 5. New Business a. DRB-000747-2026 – 15 Trellis Court – Alteration/Addition 6. Public Comment - Non Agenda Items 7. Board Business 8. Staff Reports a. Update on Design Guide. b. Report on minor projects not coming to Design Review Board. 9. Adjournment FOIA Compliance: Public notification of this meeting has been published, posted, and distributed in compliance with the South Carolina Freedom of Information Act and the requirements of the Town of Hilton Head Island. In accordance with the requirements of Title II of the Americans with Disabilities Act of 1990 ("ADA"), the Town of Hilton Head Island will not discriminate against qualified individuals with disabilities on the basis of disability in its services, programs, or activities. Auditory accommodations are available. Any person requiring further Page 1 of 69 accommodation should contact the Town of Hilton Head Island ADA Coordinator as soon as possible but no later than 48 hours before the scheduled event. Municipal Association of South Carolina (MASC) Civility Pledge: “I pledge to build a stronger and more prosperous community by advocating for civil engagement, respecting others and their viewpoints, and finding solutions for the betterment of my city or town.” Page 2 of 69 Town of Hilton Head Island Design Review Board Meeting Minutes 8/12/2026 Page | 1 Town of Hilton Head Island DESIGN REVIEW BOARD MEETING Wednesday, August 12, 2026, 2:30 PM Minutes 1. Call to Order Chair Parker called the meeting to order at 2:30 pm. In attendance were: Chair Parker, Megan Fitzpatrick, Cathy Foss, Patty Pastor and Judd Carstens. Due to a conflict, Annette Lippert and Todd Theodore were excused. 2. Adoption of the Agenda Judd Carstens moved to adopt the Agenda as presented. Cathy Foss seconded. The motion passed unanimously. 3. Approval of the Minutes a. Regular Meeting Minutes of July 22, 2026 Cathy Foss moved to approve the Minutes of July 22, 2026. Patty Pastor indicated two changes. Megan Fitzpatrick seconded. The motion passed unanimously. 4. Unfinished Business 5. New Business a. DRB-000751-2026 - 40 Waterside Drive - Final Kendal Wagner presented 40 Waterside Drive Final as included in the agenda packet. The applicant answered questions from the Board. Patty Pastor moved to approve with the following conditions: the board concurs with the majority of staff comments, with a few exceptions. Regarding 2) the pavilion roofline, the board agrees that the original design is more appropriate than the stack. With regard to 4) pool shower screening, the applicant has indicated the area currently located at the front will become just a foot washing station. The shower in the back will become a full-head shower rinsing area; punched metal screen — the majority of the Board agrees that the current metal screen is appropriate; the chain-link fence will be changed to be similar to the pool fence regarding the site furnishing palette, as well as the bike rack color; agreement with regard to the detectable warning service. In addition to the changes to staff comments above, make note regarding the placement of the 120 wall sconces as well as the 25 recessed lights. Top seating was removed. Therefore, there was no requirement to provide photo metrics regarding the TVs; study the color of the pool building downspout; provide additional information regarding the spa that was added from the conceptual design; remove the African Iris and replace them with Holly or Podoocarpos. Megan Fitzpatrick seconded. The motion passed unanimously. Page 3 of 69 Town of Hilton Head Island Design Review Board Meeting Minutes 8/12/2026 Page | 2 6. Public Comment - Non Agenda Items Skip Hoagland spoke on multiple topics, including current taxes, accommodations, hospitality and the budget. 7. Board Business 8. Staff Reports There were no staff reports. Patty Pastor requested an update on the Design Guide and Chair Parker requested an update on projects that are going through minor approvals that do not come before the Board. 9. Adjournment The meeting was adjourned at 3:21 pm. Page 4 of 69 MEMORY MATTERS RENOV AION 15 TRELLIS COURT “ADDITION” REVIEW AUGUST 26, 2026 DRB-000747-2026 Page 5 of 69 1 PROJECT NAME: MEMORY MATTERS RENOVATION DRB#: DRB-00747-2026 DATE: 08/26/2026 CATEGORY: Alteration/Addition RECOMMENDATION: Approval Approval with Conditions Denial APPLICATION MATERIAL DRB REQUIREMENTS Complies Yes No Not Applicable Comments or Conditions Demolition Plan if needed Existing Conditions match As-Built Dimensioned Details and of Sections Detail Illustrating Connection to Existing Structure New Building Details Match Existing Building Details ARCHITECTURAL DESIGN DESIGN GUIDE/LMO CRITERIA Complies Yes No Not Applicable Comments or Conditions Structure is designed to be appropriate to the neighborhood Promotes pedestrian scale and circulation Design is unobtrusive and set into the natural environment Utilizes natural materials and colors Avoids distinctive vernacular styles Design is appropriate for its use All facades shall have equal design characteristics DESIGN TEAM/DRB COMMENT SHEET The comments below are staff recommendations to the Design Review Board (DRB) and do NOT constitute DRB approval or denial. Page 6 of 69 2 Avoids monotonous planes or unrelieved repetition Has a strong roof form with enough variety to provide visual interest Overhangs are sufficient for the façade height. Forms an details are sufficient to reduce the mass of the structure Human scale is achieved by the use of proper proportions and architectural elements Utilizes a variety of materials, textures and colors Using same materials and colors as the existing building. Color Board needs to be provided Incorporates wood or wood simulating materials Windows are in proportion to the facade Details are clean, simple and appropriate while avoiding excessive ornamentation Utilities and equipment are concealed from view Decorative lighting is limited and low wattage and adds to the visual character Accessory elements are designed to coordinate with the primary structure LANDSCAPE DESIGN DESIGN GUIDE/LMO CRITERIA Complies Yes No Not Applicable Comments or Conditions Treats the Landscape as a major element of the project Provides Landscaping of a scope and size that is in proportion to the scale of the development Landscape is designed so that it may be maintained in its natural shape and size Preserves a variety of existing native trees and shrubs Provides for a harmonious setting for the site’s structures, parking areas or other construction Location of existing trees and new trees provides street buffers, mitigation for parking lots, and an architectural complement that visually mitigates between parking lots and building(s) Shrubs are selected to complement the natural setting, provide visual interest and screen less-desirable elements of the project A variety of species is selected for texture and color Provides overall order and continuity of the Page 7 of 69 3 COMMENTS & CONDITIONS 1. Staff recommends approval with conditions: a. Physical color board be provided, b. Other plan reviews submitted (Minor Development Plan Review) Landscape plan Native plants or plants that have historically been prevalent on the Island are utilized A variety of sizes is selected to create a “layered” appearance for visual interest and a sense of depth The location of existing mature trees is taken into account in placement of shrubs so as not to damage tree roots Proper spacing and location for plants to reach their mature size and natural shape while avoiding excessive or unnatural pruning Proposed groundcovers are evergreen species with low maintenance needs Large, grassed lawn areas encompassing a major portion of the site are avoided The adjacent development is taken into account in determining the most appropriate buffer so as not to depart too dramatically from the neighborhood Ornamentals and Annuals are limited to entrances and other focal points NATURAL RESOURCE PROTECTION DESIGN GUIDE/LMO CRITERIA Complies Yes No Not Applicable Comments or Conditions An effort has been made to preserve existing trees and under story plants Supplemental and replacement trees meet LMO requirements for size, species and number Wetlands if present are avoided and the required buffers are maintained Sand dunes if present are not disturbed Page 8 of 69 MEMORY MATTERS RENOV AION 15 TRELLIS COURT PROJECT NARRATIVE Page 9 of 69 Town of Hilton Head Island 1 (z.q Community Development Department 1Town Center Court Hilton Head Island, SC 29928 Phone 843-341-4757 Fax 843 341 2087 hiltonheadslandcgoy FOR OFFICIAL USE ONLY ate Received Accepted by so». Tr72@ APPLICATION PACKET FOR MAJOR CORRIDOR REVIEW (MAJOR DPR) Applicant Property Owner ,Name: JVD CA@TN Name: ww04 W+Tc-?S Phone:3 7$7 7f e Phone: 843 8f ii88Mailing Address: Po [30x 303, Mailing Address: ( Ts ouTvft(ox, $- 744[o +Ht,s 44£mat: JvO Q wuJl TD,r Email: JI@ MY 404 wAT-rs.oTown Business License # (if applicable): J[ Ho&Np x.If1 Project Information Parcel Number(w)RS_II @@ do 6fG 0@oProject Name: woq wAP$ %v4 7oJProject Address. (5 -TR€AS ougTzoning District A4HT iNpus1{k, [overlay District(s): o - eC+Project Description- p3u(DIN, No/A4T70Nl J] A<<SS[3eRAMP AD oUToR q42DN SRA.Project Category: []Concept Approval- Proposed Development D Final Approval- Proposed Development 2Aeration/Addo]sen »e7,28.¢ one 7-32 Are there recorded private covenants and/or restrictions that are contrary to, conflict with, or prohibit the proposed request? If so, a copy of the private covenants and/or resyictions must be submitted with this application [vEsor voDisclaimer: The Town of Hilton Head 1sland assumes no legal or financial liability to the applicant or any third party whatsoever by approving the plans associated with this permit. I hereby acknowledge by my signature below that the foregoing application is complete and accurate and that lam the owner of the subject property As applicable, 1authorize the subject property to be posted and inspected oeroo«is«ore \Ai'be)std loApplicant Signature: U' tAL Town of Hilton Head Island Major Corridor Review Application Updated 1 11 2025 Page 10 of 69 Town of Hilton Head Island Community Development Department 1 Town Center Court Hilton Head Island, SC 29928 Phone: 843-341-4757 Fax. 843-341-2087 hilt9nhead1slands.gay ROrFIAL USE ONLY Date Received Accepted b~ -Perm«._/'1_l]lg Town of Hilton Head 1sland Affidavt of Ownership w'.~E5Sm. y hand ~nd official seal this 3 day of J\.1 \1 .A.O., 2~. lo /'ya_ w» conmssion ere,, _MALy 1,03/w«tar PuelSignature Peeletoramp AFFIDAVIT OF OWNERSHIP AND HOLD HARMLESS PERMISSION TO ENTER PROPERTY The undersigned being duly sworn and upon oath states as follows:.l. lam the current owner of the property which is the subject of this application.2. 1hereby authorize_JUDD ApsT; toat as my agent for this application only.3. All statements contained in this application have been prepared by me or my agents and are true and correct to the bestof my knowledge. 4. The application is being submitted with my knowledge and consent.S. Owner grants the Town, its employees, agents, engineers, contractors or other representatives the right to enter uponOwner's real property, located at {A cov?T (address), RSL[9goo44g_9Q90 (parcel t) for the purpose of application review, for the limitedtime necessary to complete that purpose. oescrotvon ot work: _EtpNq PKvAto! AND CqAP-N PRa!T6. Owner agrees to hold the Town harmless for any loss or damage to persons or property occurring on the private propertyduring the Town's entry upon the property, unless the loss or damage is the result of the sole negligence of the Town.7. 1acknowledge that the Town of Hilton Head Island Municipal Code requires that all construction in a Special Flood HazardZone be constructed in accordance with the following provisions that:a. any enclosed area below the base flood elevation will be used solely for parking of vehicles, limited storage oraccess to the building. This space will never be used for human habitation without first becoming fully compliantwith the Town's Flood Damage Controls Ordinance in effect at the time of conversion.b. all interior walls, ceilings and floors below the base flood elevation will be constructed of flood resistant materials.c. all mechanical, electrical and plumbing devices will be installed above base flood elevation.d. walls of the enclosed area below base flood elevation will be equipped with at least two openings which allowautomatic entry and exit of flood water. Openings will be on two different walls with at least one square inch offree area for every square foot of enclosed space and have the bottom of openings no more than a foot above grade e. the structure may be subject to increased premium rates for flood insurance from the National Flood Insurance Program. 8. 1understand that failure to abide by Town permits, any conditions, and all codes adopted by the Town of Hilton HeadIsland deems me subject to enforcement action and/or fines. rnrt are: aJi IL ae; l6,sly ±stowner se»ore. _]]Bae&dg_]lay_ oe: 7-3-22,none No.. _ms:_l]lg hu nenay nalk_. A The foregoing instrument was acknowledged before me /\[_(9y(gy5[._['Ms persona[y knayn to me or ha,troacea BL ((Lp_ _as6enutation and who did or take a am ",%%s4" ; NoTAR - Puc -{ -,: wco i-7: 0»z4 ; ?-·.,°..o'°·,Os_,ssv,7UTT,'Jkceat 8/22/202 Page 11 of 69 .ases,"ua",/•,.d•o,opo :rotoitoaturo 0tan«t plaanns nu Addition/ Alteration Corridor Review Narrative Memory Matters Renovation15 Trellis Court, Hilton Head Island, SC 29926 147-2¢ This project proposes interior and exterior renovations to the building and outdoor garden space construction for the re-located Memory Matters organization at 15 Trellis Court. This project involves improvements to the building and grounds on the 2.38-acre Light Industrial zoned parcel (RS11 008 000 0446 0000) within the Capital Business Park. The parcel was developed in 2006 for contractor offices and showroom space. The future user, Memory Matters, is an organization aimed at supporting and engaging those with Alzheimer's and dementia, their caregivers and family, and related health care providers. The primarily day-time use and alternative transportation focus of users (busing or caregiver carpool) are important aspects of property utilization. The existing lagoon will be retained and bulkhead untouched, along with the large live oaks around the building (5 significant and 1 specimen) and existing paver parking lot. A fenced outdoor garden space will be added adjacent to the building in an existing lawn area. This space is aimed at outdoor exploration and programming for the Memory Matter users, allowing them to engage (garden in raised planters) and be active (social spaces and classroom learning) within nature. The lagoon and untouched buffers along Leg O'Mutton Road and Marshland Road provide a great backdrop for the western and southern edges of the sire. Construction activities planned for the site will be limited. Tree removal is isolated and focused on providingthe garden space on the western edge of the site, as well as some pine tree removals for drainage purposes on the building corner closest to Trellis Court. All tree removal is mitigated, as well as street-front buffer addressed at Trellis Court. Grading overall is limited and associated with the garden space and improved ADA access to the front door from drop-off - the architect has coordinated covered accessible ramp system with existing parking lot paving and curbs. Landscape and tree areas along eastern property boundary and parking are to remain untouched. The renovation of the building and inclusion of outdoor engagement space will support the important work of Memory Matters within our island community. The work will also allow the use of a previously developed site to continue in a productive manner, supporting building re-use and environmental goals for Hilton Head Island. Sincerely, Judd Carstens, RLA Attachment -- DRB Form 23 Promenade St. Ste 201 Bluffton, SC 29910 Tel: 843.757.7411 Page 12 of 69 Town of Hilton Head Island MAJOR CORRIDOR REVIEW APPLICATION Minimum Requirements for Submittal [An Application Review Fee as determined by the Town of Hilton Head Island Master Fee Schedule. Checks payable to Town of Hilton Head Island. To I PAw 4 owAcompleted Affidavit of ownership D Private covenant and/or restrictlons, if applicable. M { ,'\ In Addition: For Concept Approval- Proposed Development [] Asurvey (1"=30' minimum scale) of property lines, existing topography and the location of trees meeting the tree protection regulations of Sec. 16-6-104, Tree Protection, and if applicable, location of bordering streets, marshes and beaches. Site Plan (1"-30' minimum scale) showing location of existing development. [] A site analysis study to include specimen trees, access, significant topography, wetlands, buffers, setbacks, views, orientation and other site features that may influence design. D A draft written narrative describing the design intent of the project, its goals and objectives and how it reflects the site analysis results. D Context photographs of neighboring uses and architectural styles. D Conceptual site plan {to scale) showing proposed location of new structures, parking areas and landscaping. D Conceptual sketches of primary exterior elevations showing architectural character of the proposed development, materials, colors, shadow lines and landscaping. For Concept Approval- Proposed Development [] Afinal written narrative describing how the project conforms with the conceptual approval and design review guidelines in the Design Guide. [ Final site development plan meeting the requirements of D-6.F, Site Development Plan. [] Final site lighting and landscaping plans meeting the requirements of D-6.1. Site Lighting Plan and D-6.H. Landscape Plan. [] Final floor plans and elevation drawings (1/8"=1'0" minimum scale) showing exterior building materials and colors with architectural sections and details to adequately describe the project. D A color board (ll"x17" maximum) containing actual color samples of all exterior finishes, keyed to the elevations, and indicating the manufacturer's name and color designation. D Any additional information requested by the Design Review Board at the time of concept approval, such as scale model or color renderings, that the Board finds necessary in order to act on a final application. For Concept Approval- Proposed Development ~All of the materials required for a final approval of a proposed development (see previous section). )(.A survey (1"=30' minimum scale) of property lines, existing topography and the location of trees meeting the tree protection regulations of Sec. 16-6-104, Tree Protection, and if applicable, location of bordering streets, marshes and beaches. )( Photographs of existing structure{s). Town of Hilton Head Island Major Corridor Review Application Updated I I I 1 2025 Page 13 of 69 For Concept Approval- Proposed Development D Accurate color ren rings of sign showing di nsions, type of lettering, and actual color samples. DO For freestanding signs: o Site plan (1"=30' minim! scale) s)owing location of the sign in relation buildings, parking, existing signs,and property lines. o Propose landscaping plan. [] For wall signs: o Photograph or drawil of the building di cting the proposed location of the sign. o Location, fixture e, and wattage of any pr osed lighting. J Applicant Signature: te: 7.28.2 Town of Hilton Head Island Major Corridor Review Application Updated 11 11 2025 Page 14 of 69 MEMORY MATTERS RENOV AION 15 TRELLIS COURT ARCHITECTURE PLANS Page 15 of 69 A R CH ITECT S A R CH ITECT S parkerdesigngrouparchitects 843 785 5171 POST OFFICE BOX 5010 HILTON HEAD ISLAND SC 29938 A facility upfit for: Hilton Head Island, South Carolina Memory MaƩers REVISIONS DATE DATE OF ISSUE: SHEET SGK SCALE DRAWN BY CHECKED BY JOB NO. These documents & designs are the property of Parker Design Group|Architects & are not to be used or reproduced there of or for designs, working drawings, or construction of buildings without the written authorization from the copyright owner PDG|Architects 2025 copyright C 2546 @ 15 Trellis Court FOR FINAL STATE REVIEW C.1.0 COVER SHEET 7/27/2026 WTP DPH PROJECT #1016806 F DW ICE BUFFET RAMP DOWN TO SENSORY GARDEN OFFICE OFFICE FLEX WORKSPACE LAUNDRY & JAN OFFICE 15'-8" X 9'-0" CLASSROOM STAFF COFFEE GUEST & PATIENT R.R. STAFF R.R. ADA ELEC. ELEC. BULLETIN BOARD PASS- THRU SERVING COUNTERSTOR. MUSIC ROOM FENCE & GATES TBD ART ROOM GENERAL PROGRAM AREA W.I.C. PROGRAM STORAGE OFFICE BRAIN GAME ROOM 22'-4" X 15'-2" LOCKED MEDS LOCKED FIRST AID RESTING RM UNLOCKED DOOR BETWEEN THE TWO "ZONES" OF THE BUILDING CABINETS ANTE ROOM ANTE ROOM STOR. FROM DEDICATED CATERING PARKING CONFERENCE LOBBY 19'-4" X 19'-1" 4'-0" CASED OPENING NEW CASED OPENING N DISPLAY EXIST. CASED OPENING STOR STOR DISPLAY AREA RECEPTIONIST ALCOVE ALCOVE WATER ANTE ROOM STACKED W/D DESK & DISPLAY FOUR SEASONS ROOM COPIER BY OTHERS BENCHBENCH STACKED LOCKERS TBD, TYPICAL DW NEW REFRIG HEATED CABINETPANTRY CATERING STYLE KITCHEN SUPPLIES CHECK-IN/OUT STAFFER STANDS HERE WITH MOBILE COMPUTER TV ON WALL ICE SERVER CLOSET STORAGE T.B.D. BUILT-IN CABINET DESK LEDGE LAMINATE DESK LEDGE TRAVEL DISTANCE 93'-0" TRAVEL DISTANCE 80'-0" TRAVEL DISTANCE 93'-0" FEC EXIT/EMERG SIGN EXIT SIGN EXIT/ EMER SIGN EXIT/ EMER SIGN EXIT/ EMER SIGN FEC FEC FEC EXIT/ EMER SIGN EXIT/ EMER SIGN EXIT/ EMER SIGN EXIT/ EMER SIGN CL FEC 67" ACTUAL DOOR EXIT WIDTH. 17.2" MIN. REQUIRED CLEAR WIDTH. EXIT CAPACITY = 335 OCCUPANTS 67" ACTUAL DOOR EXIT WIDTH. 17.2" MIN. REQUIRED CLEAR WIDTH. EXIT CAPACITY = 335 OCCUPANTS 33" ACTUAL DOOR EXIT WIDTH. 17.2" MIN. REQUIRED CLEAR WIDTH. EXIT CAPACITY = 165 OCCUPANTS RELOCATED HVAC UNITS DN NEW ROOF LADDER SPRINKLER LEAN-TO S/C D S/C D S/C D S/C D S/C D S/C D S/C D S/C D S/C D S/C D S/C D S/C D S/C D S/C D S/C D S/C D C C EXTERIOR EXIT/EMERG LIGHT EXTERIOR EXIT/EMERG LIGHT EXTERIOR EXIT/EMERG LIGHT EXTERIOR EXIT/EMERG LIGHT ELECTRIC DOOR OPENER ON POST EXIT SIGN S/C D S/C D S/C D EXIT/ EMER SIGN EXIT/ EMER SIGN EXIT/ EMER SIGN EXIT/ EMER SIGN EMER LIGHT EMER LIGHT FENCE & GATE W/ ELECTRONIC BYPASS - SEE LANDSCAPE GARDEN ENTRY PATTY'S SENSORY GARDEN - SEE LANDSCAPING EMER LIGHT WH FDCPIV PRIVATE OFFICE PRIVATE OFFICE R.R. DAYCARE ENTRANCE CONNECTION CONCRETE SLOPES FROM 14.2 TO 14.1 PARKING SPACE PARKING SPACE PARKING SPACE PARKING SPACE EXIST. CONCRETE EXIST. PLANTER BREEZEWAY H/C SPACE 7''-0" RAMP @1:12 LANDING 13.4 NEW CONC. 14.2 10'-0" RAMP @1:12 FLAT CONCRETE @ 12.8 BENCH BENCH FLAT CONCRETE 12.7 BENCH CANOPIED WALKWAYS EXTEND LANDSCAPE CURB AS REQUIRED SCALE: 1/8" = 1'-0" 1CODE PLAN 1/8" C.1.0 PLUMBING CALCULATION: OCCUPANCY MALE WATERCLOSET REQUIRED TOTAL D.F. REQ. FEMALE WATERCLOSET REQUIRED CODE ANALYSIS: YES ALLOWABLE BUILDING AREAS (Table 506.2): Occupancy: NON-SEPARATED I-4 INSTITUTIONAL & BUSINESS Sprinkler: Type of Construction: Design Criteria for Code Compliance as of: VB IBC 2021; IFC 2021 w/ SC amendments;DESCRIPTON: Building Floor Areas: Actual Allowed MALE LAV. REQUIRED FEMALE LAV. REQUIRED MALE WATERCLOSET PROVIDED FEMALE WATERCLOSET PROVIDED MALE LAV. PROVIDED FEMALE LAV. PROVIDED 4,564 sqft PROJECT TEAM SCOPE OF WORK: RENOVATION OF AN EXISTING BUILDING INTO TWO ZONES: ONE IS A BUSINESS OFFICE; THE SECOND PROVIDES ADULT DAYCARE. THE BUILDING IS EMPTY EACH NIGHT. SINCE I-4 CODES ARE MORE RESTRICTIVE, THEY GOVERN THIS SPRINKLED, NONSEPARATED USE BUILDING. 716 SF OF NEW SPACE IS BEING ADDED TO THE BUILDING ON THE EAST SIDE, WHICH IS WOOD FRAMING ON CMU STEM WALLS. THE EXISTING BUILDING IS 1-STORY CONSTRUCTION ON A SLAB. THE EXISTING EXTERIOR WALLS HAVE A CMU CORE, WHILE THE EXISTING INTERIOR WALLS ARE CONSTRUCTED WITH WOOD STUDS. MOST OF THE BUILDING HAS A METAL DECK ROOF. THERE ARE NO SMOKE COMPARTMENTS REQUIRED IN THIS BUILDING. INDEX OF DRAWINGS: 1-4 Institutional 1st Floor ARCHITECT: PDG-ARCHITECTS (TOM PARKER) 10 PALMETTO BUSINESS PARK SUITE 201, HILTON HEAD, SC 29928 843-348-2278 EMAIL: TOM@PDG-ARCHITECTS.COM MECH., ELECTRICAL, PLUMBING: LONDONO ENGINEERING 1011 BAY STREET, SUITE 307, BEAUFORT, SC 29902 PHONE: 843-263-1792 EMAIL: RLONDON@LONDONOENGINEERING.COM TABLE 803.13 INTERIOR WALL AND CEILING FINISH REQUIREMENTS BY OCCUPANCY GROUP SPRINKLED INTERIOR EXIT STAIRWAYS ,RAMPS AND EXIT PASSAGEWAYS CORRIDORS AND ENCLOSURE FOR EXIT ACCESS STAIRWAYS AND RAMPS ROOMS AND ENCLOSED SPACES I-4 B TABLE 1017.2 EXIT ACCESS TRAVEL DISTANCE WITH SPRINKLER 200 FEET ALLOWED OCCUPANCY I-4 Institutional ACTUAL MAX DISTANCE 95' FEET 1.53 1I-4 INSTITUTIONAL 46 1.53 MOP SINK REQ. TOTAL 86 2.33 2.03 13 3 1 1 36,000 sqft BB 2 2 STRUCTURAL: LANDSCAPE ARCHITECTURE: SHEARLOCK ENGINEERING LLC 110 TRADERS CROSS, SECOND FLR, OKATIE, SC, 29909 PHONE: 843-473-8767 EMAIL: JOSHUA@SHEARLOCKENG.COM 4,015 sqft 36,000 sqft STRUCTURAL MEP THIS WRITTEN NOTICE REQUIRED BY SOUTH CAROLINA REGULATIONS TO THE PERMITTING AUTHORITY & BUILDING OWNER THAT THE PDG-ARCHITECTS HAVE NOT BEEN HIRED TO PROVIDE MINIMUM CONSTRUCTION ADMINISTRATION SERVICES ON THE FOLLOWING PROJECT. BUSINESS (B) OCCUPANCY WITHOUT SPRINKLERS REGULATION 11-12.B.4 AND 5 STATE: (4) ON A PROJECT WHERE A BUILDING PERMIT HAS BEEN ISSUED AND THE SEALING ARCHITECT AND THE FIRM OF RECORD HAVE NOT BEEN ENGAGED TO PERFORM AT LEAST MINIMUM CONSTRUCTION ADMINISTRATION SERVICES, AS DEFINED IN SUBSECTION (5) BELOW, THE SEALING ARCHITECT AND FIRM MUST REPORT TO THE PERMITTING AUTHORITY AND THE BUILDING OWNER THAT HE AND THE FIRM HAVE NOT BEEN SO ENGAGED. (5) THE MINIMUM CONSTRUCTION ADMINISTRATION SERVICES EXPECTED OF THE SEALING ARCHITECT AND FIRM DEEMED NECESSARY TO PROTECT THE HEALTH, SAFETY, AND WELFARE OF THE PUBLIC SHALL BE PERIODIC SITE OBSERVATIONS OF THE CONSTRUCTION PROGRESS AND QUALITY, REVIEW OF CONTRACTOR SUBMITTAL DATA AND DRAWINGS, AND REPORTING TO THE BUILDING OFFICIAL AND OWNER ANY VIOLATIONS OF CODES OR SUBSTANTIAL DEVIATIONS FROM THE CONTRACT DOCUMENTS WHICH THE ARCHITECT OBSERVED. CONSTRUCTION ADMINISTRATION NOTICE: OCCUPANCYSQ.FT. / OCCUPANT OCCUPANCY CALCULATIONS USE OF SPACE SQ. FT. I-4 INSTITUTIONAL 3,683 37100 GROSS 86TOTAL 8,577 THESE DRAWINGS HAVE BEEN PRODUCED UNDER A LIMITED SERVICES AGREEMENT FOR A REDUCED FEE BETWEEN THE OWNER/OWNER'SREPRESENTATION & PDG-ARCHITECTS, INC. THEY ARE TO BE USED FOR DESIGN INTENT AND IN COORDINATION WITH SUPPLEMENT ENGINEERING DOCUMENTS. 1. THE ARCHITECT'S DRAWINGS CANNOT STAND ALONE AS CONSTRUCTION DOCUMENTS. 2. SEE STRUCTURAL ENGINEERING DOCUMENTS FOR STRUCTURAL CONNECTION TECHNIQUES, CALCULATIONS REQUIRED BY CODE, CODE COMPLIANCE INSTRUCTIONS FOR WALL AND ROOF CONSTRUCTION, AND TIE DOWN REQUIREMENTS. 3. SEPARATE MECHANICAL, ELECTRICAL, AND PLUMBING ENGINEERING DOCUMENTS ARE PROVIDED, WHICH INDICATE REQUIRED SERVICE AND RISER DIAGRAMS, CALCULATIONS AND INSTALLATION SPECIFICATIONS BEYOND THE ARCHITECTS BASIC LAYOUT AND SELECTIONS SUGGESTIONS. 4. SEPARATE CIVIL ENGINEERING DOCUMENTS ARE PROVIDED, WHICH INDICATE ADDITIONAL SITE PLANNING, DRAINAGE, AND OTHER RELATED SITE WORK REQUIREMENTS. 5. SUBMITT ALL PAINT, PAPER, TILE, AND FINISHES AS PER OWNER FOR FINAL APPROVAL.SELECTIONS NOT INCLUDED IN THESE DOCUMENTS WILL BE COORDINATED BY THE OWNER/ OWNER'S REPRESENTATIVES. 6. BY APPLYING FOR A BUILDING PERMIT AND/OR CONSTRUCTING THE PROJECT REPRESENTED HEREIN, THE OWNER AGREES TO LIMIT THE LIABILITY OF THE ARCHITECT, TO THE OWNER OF THE PROJECT, FOR ALL AND ANY CLAIMS, LOSSES, DAMAGES OF ANY NATURE WHATSOEVER, OR CLAIMS OF EXPENSES FOR ANY SUCH ITEMS TO THE ARCHITECTS TOTAL COMPENSATION FOR SERVICES RENDERED HEREIN. 7. THESE DOCUMENTS ARE THE WORK INSTRUMENTS OF THE ARCHITECT AND HAVE BEEN PREPARED SPECIFICALLY AND SOLELY FOR THE PROJECT NAMED HEREIN. THEY ARE NOT SUITABLE FOR USE ON OTHER PROJECTS OR IN OTHER LOCATIONS WITHOUT THE PARTICIPATION OF THE ARCHITECT. REPRODUCTION IS STRICTLY PROHIBITED. THE ARCHITECT SHALL BE DEEMED THE AUTHOR AND OWNER OF THESE DOCUMENTS AND SHALL RETAIN COMMON LAW, STATUTORY AND OTHER RESERVED RIGHTS, INCLUDING THE COPYRIGHT. 8. THE ARCHITECT HAS NOT BEEN CONTRACTED TO PERFORM CONSTRUCTION ADMINISTRATION/ ON-SITE OBSERVATION FOR THIS PROJECT. 9. FOR DIMENSIONS NOT SHOWN OR IN QUESTION, THE CONTRACTOR WILL REQUEST CLARIFICATION FROM THE ARCHITECT BEFORE PROCEEDING. 10. CONTRACTOR WILL VERIFY ALL EXISTING CONDITIONS IN THE FIELD, ANY DISCREPANCIES WILL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT. 11. THE CONTRACTOR SHALL MAINTAIN AT THE SITE OF THE WORK, A SET OF RECORD DRAWINGS. THE CONTRACTOR SHALL RECORD ALL CHANGES AND DEVIATIONS FROM THE DRAWINGS ON THIS "AS-BUILT" SET, WHICH SHALL BE UPDATED A LEAST EVERY OTHER WEEK. AT THE CLOSE OF THE JOB, THE CONTRACTOR SHALL PROVIDE ONE COMPLETE SET OF ALL AS-BUILT INFORMATION TO THE ARCHITECT IN CLEAR AND LEGIBLE FORMAT. 12. WHEN ARCHITECTURAL DRAWINGS ARE IN CONFLICT WITH ENGINEERING DRAWINGS THE GENERAL CONTRACTOR SHALL REQUEST CLARIFICATION FROM THE ARCHITECT BEFORE PROCEEDING. 13. BEGINNING OF WORK BY ANY TRADE SHALL CONSTITUTE ACCEPTANCE & RESPONSIBILITY FOR EXISTING CONDITIONS AND SUBSTRATE AS APPLICABLE UNLESS OTHERWISE INIDCATED IN WRITING PRIOR TO COMMENCEMENT OF WORK. GENERAL NOTES: ARCHITECTURAL & SITE C.1.0 TITLE SHEET A.1.1 FIRST FLOOR PLAN A.1.0 AS-BUILT AND DEMO PLAN S.1.2 PROPOSED SITE PLAN VICINITY PLAN : WITMER JONES KEEFER, LTD. 23 PROMENADE STREET, SUITE 201, BLUFFTON, SC 29910 PHONE: 843-757-7411 EMAIL: JUDD@WJKLTD.COM B Business 1st Floor B BUSINESS 49100 GROSS 4,894 B Business 1st Floor 300 FEET ALLOWED 105' FEET 40 0.80 1 1 0.50 3 2 1 3 2 1 B BUSINESS A.1.2 REFLECTED CEILING PLAN A.2.0 EXTERIOR ELEVATIONS A.3.0 BUILDING & WALL SECTIONS A.1.3 SCHEDULES & DOOR/WINDOW TYPES A.5.0 ENLARGED FLOOR PLANS & ELEVATIONS A.5.1 ENLARGED FLOOR PLANS & ELEVATIONS A.1.4 FURNITURE PLAN A.3.1 SECTIONS & DETAILS CS COVER SHEET - LANDSCAPING 2021 International Codes for Plumbing, Mechanical, & Fuel Gas; 2020 National Electrical Code; 2009 International Energy Conservation Code (IECC); South Carolina Dept. of Health Regulation 60-75 Stds for Licensing Day Care Facilities for Adults; 1.53 2.33 0.80 1.53 2.03 0.50 ANSI A117.1 2017 S100 STRUCTURAL NOTES S201 FOUNDATION PLAN S200 DEMOLITION PLAN S203 CEILING FRAMING PLANS S202 SLAB PLAN S204 ROOF FRAMING PLANS S210 SHEAR WALL PLAN S300 FOUNDATION DETAILS S400 STRUCTURAL DETAILS S401 STRUCTURAL DETAILS S402 STRUCTURAL DETAILS M002 HVAC SCHEDULES M001 HVAC DETAILS M101 HVAC PLAN E001 ELECTRICAL DETAILS E002 ELECTRICAL SCHEDULES E101 POWER PLAN E101 LIGHTING PLAN P001 PLUMBING DETAILS P002 PLUMBING SCHEDULES P101 SANITARY SEWER PLAN P201 WATER DISTRIBUTION PLAN L10 REFERENCE PLAN - EXISTING CONDITIONS L50 DEMOLITION PLAN L200 LAYOUT PLAN L300 GRADING PLAN L500 PLANTING PLAN L501 PLANT SCHEDULE & DETAILS L600 SITE DETAILS - 01 L600 SITE DETAILS - 02 6/16/26 Page 16 of 69 A R CH ITECT S A R CH ITECT S parkerdesigngrouparchitects 843 785 5171 POST OFFICE BOX 5010 HILTON HEAD ISLAND SC 29938 A facility upfit for: Hilton Head Island, South Carolina Memory MaƩers REVISIONS DATE DATE OF ISSUE: SHEET SGK SCALE DRAWN BY CHECKED BY JOB NO. These documents & designs are the property of Parker Design Group|Architects & are not to be used or reproduced there of or for designs, working drawings, or construction of buildings without the written authorization from the copyright owner PDG|Architects 2025 copyright C 2546 @ 15 Trellis Court FOR FINAL STATE REVIEW S.1.2 RAMP ON SITE PLAN 7/27/2026 WTP DPH PROJECT #1016806 I T AC CO 1/2" IPF 1/2" IPF AC AC LOT 18 LOT 17 MARSHLAND ROAD 66' R/W SINGLE STORY BUILDING LEG OF MUTTON ROAD 50' R/W TRELLIS COURT LOT 19 15' BUILDING SETBACK 15' BUILDING SETBACK BIKE PATH EASEMENT 15' BUILDING SETBACK EDGE OF PAVEMENT BIKE PATH BIKE PATH BIKE PATH EDGE OF PAVEMENT EDGE OF PAVEMENT EDGE OF WATER EDGE OF WATER BACK OF CURB BACK OF CURB BACK OF CURB 15' BUILDING SETBACK BACK OF CURB EDGE OF PAVEMENT WOOD FENCE PAVER DRIVEWAY PAVER DRIVEWAY 1.5' HEADWALL 1.5' HEADWALL 1' PLANTER 0.5' CONCRETE WALL 70.5' 66.4' 113.9' 122.1' 22.4' 111.2' 79.2' 1/2" IPF W/CAP CONCRETE PATH S.C. GRID ISLAND DRIVE INDIAN TRAIL MARBLEHEAD ROAD MARBLEHEAD ROAD MARSHLAND ROAD CAPITAL DRIVE LEG-O-MUTTON ROAD WHITNEY PLACE VICTORIA SQUARE DRIVE WOOD DECK TBM SET NAVD 88 ELEVATION = 15.01' CONCRETE TRAFFIC ISLAND CONCRETE TRAFFIC ISLAND 1.5' HEADWALL 0.5' CONCRETE WALL RIP-RAP EDGE OF WATER TOP OF BANK TOP OF BANK 1.5' HEADWALL CONCRETE SIDEWALK CONCRETE RAMP 18" HDPE 18" HDPE LAGOON PLAT BOOK 102 PAGE 193 9 8 7 GRAVEL EDGE OF WATER FLOOD ZONE X N/A FLOOD ZONE X SHADED N/A FLOOD ZONE X SHADED N/A FEMA FLOOD LINE VICINITY MAP N.T.S.N.T.S. THIS DOCUMENT ORIGINALLY ISSUED AND THIS ELECTRONIC MEDIA SHALL NOT BE A CERTIFIED HARDCOPY MAY BE OBTAINED FROM SEALED BY JUSTIN R. KESSELRING S.C.R.L.S. # 29901 CONSIDERED A CERTIFIED DOCUMENT. NANDINA, INC. UPON REQUEST BEACHFRONT SETBACK REQUIREMENTS OF THE S.C. BEACH PROTECTION 3) SUBJECT PROPERTY DOES NOT APPEAR TO BE AFFECTED BY THE 1) UNDERGROUND UTILITIES NOT LOCATED EXCEPT AS SHOWN. 7) USE OF THIS PROPERTY MAY BE AFFECTED BY THE TERMS OF COVENANTS RELATING TO THIS PLANNED COMMERCIAL DEVELOPMENT. 8) BUILDING SETBACKS, WHETHER SHOWN OR NOT, SHOULD BE VERIFIED BY THE LOCAL BUILDING AUTHORITY OR ARCHITECTURAL REVIEW BOARD. BASE FLOOD ELEVATION = N/A THIS PROPERTY LIES IN F.E.M.A. ZONES X & X SHADED PROPERTY AREA = 2.39 Ac. 103,917 Sq. Ft. RECORDED IN BOOK 58, PAGE 153 BEAUFORT COUNTY, SC COMMUNITY NO. 450250, PANEL 0454G, DATED: 3/23/2021 ADDRESS: 15 TRELLIS COURT DISTRICT: 511, MAP: 8, PARCEL: 446 REFERENCE PLATS ROD. BY: 1) A SUBDIVISION PLAT OF 19 LOTS AT THE A. J. TRUST SITE, DRAWN: 10/14/1996 A SECTION OF MARSHLAND ROAD & LEG O'MUTTON ROAD AREA, JACK JONES S.C.R.L.S. #13852 ACT OF JULY 1, 1988. NOTES: 4) HORIZONTAL DATUM IS S.C. STATE PLANE COORDINATES NAD83. 5) VERTICAL DATUM IS NAVD88. 6) CONTOUR INTERVAL IS 1'. 9) THIS SURVEY HAS BEEN PREPARED WITHOUT BENEFIT OF A COMPLETE TITLE SEARCH AND IS SUBJECT TO EASEMENTS AND RESTRICTIONS OF RECORD. COPYRIGHT BY NANDINA, INC. CAD: INDOVANCE, FLD: CM, RB SCALE :DATE : 1" = 20' HILTON HEAD ISLAND, LOT 18, CAPITAL BUSINESS PARK, BEAUFORT COUNTY, SOUTH CAROLINA 09/30/2025 ASBUILT, TREE AND TOPOGRAPHIC SURVEY OF: d.b.a. Sea Island Land Survey, Inc. DWG No. :FILE No : 25308 5-25308 E 6040200 GRAPHIC SCALE E-mail: admin@nandinainc.com Hilton Head Island, SC 29926 Tel (843) 681-3248 PREPARED FOR: EURORISORE , LLC 10) THIS SURVEY DOES NOT CERTIFY TO THE EXISTENCE OR ABSENCE OF FRESHWATER WETLANDS. 2) NANDINA, INC. CERTIFIES TO THE BOUNDARY, TOPOGRAPHIC AND ASBUILT INFORMATION PROVIDED HEREON AS THE DATE OF THE SURVEY. THIS SURVEY MAY BE USED IN DIGITAL FORMAT AS A BASE FOR OTHERS AND ANY REVISIONS OR ADDITIONS MADE HEREAFTER IS NOT THE RESPONSIBILITY OF NANDINA, INC. A HARD COPY AVAILABLE FROM NANDINA, INC. WILL BE THE ONLY OFFICIAL DOCUMENT. 11) IF IDENTIFICATION OF TREES IS CRITICAL TO DEVELOPMENT, AN ARBORIST SHOULD BE CONSULTED TO VERIFY SUCH TREE IDENTIFICATION. 10 Oak Park Drive, Unit C1, INVERT ELEVATION POLYVINYL CHLORIDE MAPLE PALM WATER OAK IE PVC LIVE OAKLO LAUREL OAKLA MAP PECANPEC PINEPN PLM WO TREE SIZES ARE INCHES IN DIAMETER 3" CONCRETE MONUMENT FOUND SPOT ELEVATION TEMPORARY BENCH MARK 9 LEGEND & SYMBOLS: TBM 9.5 CONTOUR 3" CMF SUGAR BERRYSB REINFORCED CONCRETE PIPERCP HIGH DENSITY POLYETHYLENE PIPEHDPE 1/2" IRON PIN FOUND1/2" IPF AC A/C UNIT COMMUNICATION VAULTT TELEVISION SERVICE CLEANOUTCO GRATE INLET IRRIGATION CONTROL VALVEI SIGN TELEPHONE SERVICET ELECTRIC TRANSFORMER WATER METER CHERRYCH TUPELOTUP HILTON HEAD ISLAND, BEAUFORT COUNTY, SOUTH CAROLINA SITE WATER OAKWO RECORDED IN BOOK 102, PAGE 193, DATED 12/02/2004 BEAUFORT COUNTY, SCROD. BY: 2) BIKE PATH EASEMENT OVER LOT 18, CAPITAL BUSINESS PARK, DRAWN: 2/13/2004 A SECTION OF MARSHLAND ROAD & LEG O'MUTTON ROAD AREA, RALPH O. VANADORE S.C.R.L.S. #7606 HILTON HEAD ISLAND, BEAUFORT COUNTY, SOUTH CAROLINA 3 BSCK TPN GPS 2 4 X ON DW 22 BSCK PK GPS 1 11.1 10.8 11.2 11.3 11.1 11.3 11.5 11.4 11.5 11.8 11.8 11.9 12.1 11.9 11.9 12.0 12.0 12.2 12.3 12.1 12.2 12.1 12.2 12.4 12.3 12.3 12.3 12.3 11.6 11.7 11.9 11.8 11.7 12.1 12.3 12.3 12.3 12.3 12.4 12.4 12.8 12.9 12.9 12.8 12.8 12.7 12.712.712.7 12.1 14.3 14.3 14.3 ICV WMWM CATV 172 3X2 COM VAULT 173 4" COND174 TRNSFRMR TEL PED 13.5 13.2 12.7 13.1 12.7 13.2 12.6 12.7 13.2 13.2 12.7 12.7 13.1 13.1 12.6 12.4 13.0 12.9 12.4 14.2 12.1 197 COR GI EP 198 COR GI EP 199 COR GI EP 200 COR GI EP 10.8 11.1 PLM 14 12.1 PLM 16 LAO 8 LAO 8 PN 20 LAO 9 PN 16 PN 18 PN 16LAO 9 PN 20 PLM 13 PLM 12 PLM 14 PLM 8 PLM 9 PLM 16 PLM 16 LAO 8 PN 12 WO 10 PN 16 MAP 9 PN 24 CYP 6 LO 15 LO 17 231 BSCK PK GPS 1 12.8 13.3 13.3 13.3 13.3 13.413.3 13.4 13.4 13.2 PLM 14 PLM 13 CO PLM 14 LO 5-9-10-11-13-16-17 14.2 12.7 11.8 12.4 LO 13-16-19 13.8 11.9 12.5 12.4 LO 26 LO 6 PLM 16 PLM 14 PLM 13 12.2 11.9 12.3 12.3 12.2 12.2 12.1 11.9 12.0 12.0 11.9 11.7 11.9 12.1 12.112.2 12.3 12.5 12.4 12.0 12.3 12.2 10.3 PLM 16 LAO 9 11.6 LO 26 PN 26 PLM 12 WO 7 11.7 LO 15 LO 18 LAO 16 PN 6 11.2 PN 12 LO 28 10.5 12.4 8.6 309 BSCK X ON CON 4 PLM 16 13.0 12.4 12.4 12.9 13.1 12.6 12.7 12.7 14.0 14.014.0 13.4 13.4 13.2 13.1 12.9 12.7 13.1 13.2 14.2 14.3 14.3 14.0 13.9 13.4 13.5 13.1 13.313.4 13.4 14.1 14.1 12.7 12.7 13.2 12.9 12.5 12.412.9 12.9 12.5 12.2 12.8 11.9 12.1 12.1 12.1 12.0 13.9 PLM 10 11.6 13.7 LO 24 LO 15-22 13.3 11.9 PLM 28386 BSCK TPN 24 PLM 17 PLM 18 WO 7-19 MAP 6 392 11.193 DECK393 10.640 DECK 394 10.640 DECK 395 11.208 DECK 396 9.025 DECK397 8.958 DECK 398 8.950 DECK 399 9.028 DECK 400 9.533 STP 401 10.664 STP 402 10.665 STP 403 9.560 STP 11.9 PN 9 PN 6 PN 29 12.1 12.0 12.2 PN 9 PN 6-12PN 9 PN 11-12 11.2 6.9 11.2 6.8 10.1 420 7.092 IE 18 " HDPE 422 9.548 CLFE9.0 7.5 10.3 7.4 PN 17 PN 14 WO 13 9.9 7.3 WO 6 LAO 6 WO 8WO 8 10.5 7.2 PN 14 PEC 8 LO 12-14-17 LAO 6 6.8 PN 22 PN 22 TUP 6-6 PN 16 PN 9 PN 18 PN 18 WO 7 LAO 7 LAO 10 PN 7-8-21 PN 14 PN 19 10.0 7.2 462 BSCK TPN 24 PN 15 PN 19 LAO 6LAO 7 LAO 10 LAO 10 471 6.178 IE 18" RCP FLARE 472 6.146 IE 18" RCP FLARE 473 6.167 IE 24" RCP FLARE 474 6.289 IE 24" RCP FLARE 475 8.165 IE 15"HDPE 476 BSCK TPN 24 PN 20 PN 19 10.4 WO 7 10.2 LAO 7-7 LO 15 10.6 LO 19 LO 10 490 5.988 IE 18" HDPE 494 5.799 IE 18" HDPE 8.1 LO 24 10.0 LO 31 WO 8 WO 6 LAO 6 WO 7-7 WO 8 LO 10 LAO 7-7 LAO 8 LAO 7 LAO 7 LAO 11 CH 8 LAO 6 WO 10 LAO 6 WO 14 LAO 20 SB 11 LO 12 DEAD WO 9 9.8 10.7 WO 8 PN 8 LAO 6 10.0 7.4 10.5 9.2 10.6 11.5 9.5 11.3 11.2 537 6.140 IE 18"HDPE 10.6 10.1 10.6 10.2 6.8 10.5 6.7 LAO 13 CH 7 WO 9 WO 6 WO 11 LO 25 WO 6 LAO 15 LO 18 10.3 558 BSCK TPN GPS 2 PN 7 WAX 12 LO 16 9.7 6.7 10.0 7.0 568 10.437 END WDFE 10.1 10.2 10.2 572 8.373 IE 18"HDPE 9.2 10.2 10.3 10.7 10.6 10.6 10.8 11.0 10.7 10.4 9.5 10.4 10.4 10.3 10.3 9.7 10.1 10.1 10.2 9.5 10.2 10.7 10.9 10.6 10.5 10.2 9.3 9.8 10.0 9.9 9.7 9.5 9.9 10.1 10.3 10.1 609 TRASH 10.0 10.4 10.3 10.1 9.5 9.9 10.1 10.510.410.410.410.5 10.3 10.5 10.5 10.7 10.4 10.4 10.2 10.5 10.6 10.1 9.9 10.0 636 9.990 WDFE 10.6 10.7 10.9 10.8 10.9 10.7 10.6 10.5 10.5 10.5 10.1 648 BSXK TPN 22 9.6 9.3 651 9.781 WDFE 9.8 9.9 10.1 10.1 10.1 10.0 9.9 9.8 9.8 9.9 10.7 10.9 11.1 11.1 11.0 10.9 10.2 9.9 9.8 9.8 10.0 9.9 9.8 10.0 10.3 10.1 10.4 10.5 11.1 11.0 11.311.4 11.4 11.2 11.712.2 12.4 12.1 12.0 11.6 11.311.711.9 11.5 11.2 10.8 698 YLD SGN 10.8 11.2 10.5 10.5 10.7 704 STOP SGN 705 10.091 WDFE 706 10.666 PDR 24" RCP 707 10.679 PDR 24" RCP 708 8.283 PDR 18" RCP 709 8.281 PDR 18" RCP 710 BSCK TPN 27 N43°23'37"E 336.64' C1 S71°20'55"W 186.95' C2 N16°23'26"W 103.88' L1 L2L3 STEPS STEPS 0.5' PLANTER N:134964.16 E:2089609.50 N:134976.48 E:2089509.78 N:134731.86 E:2089278.50 10.9 10.6 8.7 10.1 10.1 10.2 11.3 11.3 11.3 11.4 11.5 11.4 10.9 11.2 11.9 11.6 11.4 11.2 11.6 11.9 11.1 11.2 11.1 11.1 10.8 10.6 10.9 10.2 10.6 10.6 10.4 10.6 11.0 10.8 9.8 10.2 11.110.7 11.0 11.1 10.8 10.2 11.4 11.5 11.2 11.2 10.7 10.9 10.9 11.1 11.2 11.2 10.8 10.7 11.0 11.0 10.8 11.0 11.1 11.2 12.3 11.4 12.4 12.1 12.1 12.1 12.1 11.4 11.4 10.7 13.1 12.1 13.1 12.1 12.2 11.9 11.9 12.3 10.9 10.9 10.9 11.2 11.3 11.311.4 11.0 10.410.6 9.6 9.6 11.4 11.0 11.4 11.5 11.7 11.6 11.7 12.2 12.3 11.7 11.9 12.5 12.3 12.1 11.8 12.2 11.8 11.8 11.7 12.5 12.1 12.4 12.3 12.1 12.212.1 12.1 12.2 12.2 12.7 11.9 11.8 11.7 11.7 12.5 12.6 12.3 12.0 11.7 13.2 13.3 13.1 10.5 9.6 10.2 12.1 12.6 TOP OF BANK SLATE SIDEWALK LOADING/UNLOADING DOCK STEPS 4" CONDUIT TRASH CAN 2' BENCH WOOD DECK TREE DRIPLINE LO 13-16-19 TREE DRIPLINE LO 5-9-10-11-13-16-17 0.8' WALL 0.8' RETAINING WALL FLAG POLE TOP OF BANK IE=8.73' IE=6.14' IE=5.99' IE=5.80' 0.8' WALL 15" HDPE IE=8.17' 18" RCP (FLARED) IE=6.18' IE=6.15' 18" HDPE IE=7.09' 24" RCP (FLARED) IE=6.29' IE=6.17' GAS GRILL 0.5' PLANTER 12.1 11 12 12 12 12 12 12 11 12 13 12 12 12 12 12 12 13 14 12 12 10 10 10 11 10 11 11 10 10 10 1011 11 10 11 11 11 10 11 11 10 9 8 10 8 9 10 9 10 7 8 9 11 S17°33'40"E 298.19' 11 CONCRETE LANDING L4 L5L6 C3L7 L8 L9 C4 L10 C5 L11 L12 LINE TABLE LINE L1 L2 L3 L4 L5 L6 L7 L8 L9 L10 L11 L12 LENGTH 56.67' 31.28' 40.45' 18.01' 89.95' 150.78' 15.47' 43.54' 7.30' 22.25' 151.23' 90.52' BEARING S72°15'20"W S72°43'03"W S73°36'34"W N17°34'11"W S70°45'38"W N70°29'04"E N59°00'42"E N78°45'54"E S11°14'06"E N59°00'42"E N70°29'04"E N70°45'38"E CURVE TABLE CURVE C1 C2 C3 C4 C5 LENGTH 110.10' 116.24' 17.12' 40.96' 20.21' RADIUS 75.00' 74.00' 120.85' 235.74' 138.85' TANGENT 67.66' 74.00' 8.57' 20.53' 10.12' CHORD 100.48' 104.65' 17.10' 40.91' 20.20' CHORD BEARING S82°57'08"E S61°23'26"E S63°41'49"W N64°57'35"E S63°46'03"W DELTA 084°06'49" 089°59'53" 008°06'57" 009°57'17" 008°20'28" PN 14 PLM 12 PLM 12 PN 18PN 13 PN 16 CED 6 11.5 12.0 11.2 10.5 10.6 6.0 6.1 9.5 10.4 5.9 LA 8 PN 16 PLM 12 CED 7 PN 10 12.1 12.1 11.8 12.1 12.0 12.1 12.1 12.1 11.7 11.4 11.8 11.8 11.6 12.3 12.2 11.7 F DW 7'-0"-WIDE FLAT CONCRETE W/ T.B.D. BENCHES TOTAL SLOPE AT 1:12 TO BENCHES IS APPROX 1'-0" DROP OR 17'-0" OF RAMP EXTEND CONCRETE LANDSCAPE CURB AS REQ'D ADDITIONAL ROOMS 716 SF FOOD DELIVERIES FORMER RAMP FILLED IN TO GRADE PATTY'S SENSORY GARDEN - SEE LANDSCAPE 23 EXISTING PARKING SPACES ARE AVAILABLE TO 10 FT STAFF, 3 PT STAFF & 6 VOLUNTEERS (AS WELL AS VISITORS) ON A DAILY BASIS. ONE RESERVED SPACE IS BEING ADDED FOR USE BY THE FOOD DELIVERY DRIVER FDC PIV FIRE HYDRANT IS LOCATED ON TRELLIS COURT, < 500' FROM BLDG. FOOD DELIVERY PARKING ONLY SILT FENCE SILT FENCE SILT FENCE 4-YD DUMPSTER IN SERVICE YARD ON 6 IN. CONC. PAD - SEE DETAILCONSTRUCTION DUMPSTER WASHOUT BOLLARDS CONSTRUCTION STAGING AREA - CONTRACTOR TO MAINTAIN SEDIMENT CONTROL AS REQUIRED SILT FENCE LARGE-DONOR PLAQUE ON STONE BASE T.B.D. HYDRANT LOCKED GATE W/ ELECTRIC BYPASS - SEE LANDSCAPE SILT FENCE NON-PERMEABLE CONSTRUCTION: CONSTRUCTED FOOTPRINT: 8,579 SF LAGOON SURFACE: 25,908 SF NON-PERMEABLE PAVING: 13,121 SF OTHER NON-PERMEABLE: 8,331 SF TOTAL NON-PERMEABLE: 55,939 SF 55,939 NON-PERM/103,852 (LOT) = 54% SITE 7'-0" RAMP @1:12 LANDIN G NEW CONC.14.2 10'-0" RAMP @1:12 CONNECTION CONCRETE SLOPES FROM 14.2 TO 14.1 EXIST. CONC.14.1 FLAT CONCRETE @ 12.7 DEMOLISH EXISTING WALK DEMOLISH EXISTING WALK 13.4 FLAT STEPS FLAT FLAT HANDICAPSTALL HANDICAPSTALL S.1.2 Page 17 of 69 A R CH ITECT S A R CH ITECT S parkerdesigngrouparchitects 843 785 5171 POST OFFICE BOX 5010 HILTON HEAD ISLAND SC 29938 A facility upfit for: Hilton Head Island, South Carolina Memory MaƩers REVISIONS DATE DATE OF ISSUE: SHEET SGK SCALE DRAWN BY CHECKED BY JOB NO. These documents & designs are the property of Parker Design Group|Architects & are not to be used or reproduced there of or for designs, working drawings, or construction of buildings without the written authorization from the copyright owner PDG|Architects 2025 copyright C 2546 @ 15 Trellis Court FOR FINAL STATE REVIEW A.1.0 AS-BUILT & DEMO PLAN 7/27/2026 WTP DPH PROJECT #1016806 F F DW ICE DN OFFICE RECEPTION ENTRANCE 2CONFERENCE LOBBY OFFICE LAYOUT AREA REST ROOM BREAK-2 OFFICE OFFICE OFFICE MECH MAIL/COPY OFFICE LIBRARY BREAK ROOM LAYOUT COUNTER 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2 3 3 3 3 33 3 3 3 3 33 3 3 3 3 3 1 2 3 3 4 4 4 4 1 2 6 6 11 1 3 3 3 3 OFFICE 9'-11" BEAD BOARD PAINTED BEAM CEILING REST RM 4 9 8'-11" GYP. CEILING 9 10 11'-3" GYPSUM BOARD CEILING DISPLAY AREA 13'-2 OPEN DECK 12'-8" OPEN DECK 12'-3" OPEN DECK 12'-3" OPEN DECK9'-8" ACT CEILING 12 13 1212 9'-8" ACT CEILING OFFICE 9'-8" ACT CEILING 12'-5" OPEN DECK 9'-11" GYP. CEILING W/STAINED BEAMS 9'-11" GYP. CEILING 9'-11" GYP. CEILING W/STAINED BEAMS 10'-11" GYP. CEILING 11'-2" GYP. CEILING REAL BRICK WALL STAINED WAINSCOT & GRASSCLOTH GYPSUM STAINED WAINSCOT 2 9 10 2 1 1 3 SERVER CORR 9'-11" GYP. CEILING 9'-11" GYP. CEILING STOR STOR DISPLAY AREA 8'-11" GYP. CEILING REST RM CERAMIC TILE 1 1 8'-11" GYP. CEILING CPT 14 COPIER SPACE CABINETS & COUNTER 15 CABINETS & COUNTER REMAIN 10 3 3 3 5 16 17 RELOCATE FIRE EXTING. CABINET HERE 18 18 19 1 1 1 1 1 1 20 21 1 1 EXISTING ARCHED SOFFIT 22 22 22 22 CORR CORR CORR 22 22 2222 22 22 22 22 22 2222 22 22 22 22 22 22 22 2222 11 7 23 24 ELEC. 10 25 25 9 10 REUSE IN BRAIN GAME ROOM 104 REUSE THE "HUTCH" ABOVE THE COUNTER TO THE COUNTER ON BACK WALL OF RECEPTIONIST'S OFFICE #136 REUSE 4 WOOD FILE CABINETS TO HOLD NEW WORK LEDGE IN FLEX ROOM 128 REUSE 4 UPPER & LOWER WHITE CABINETS AT SPACE BY ALCOVE 132 3 4 LAYOUT COUNTER 3 3 3 3 3 3 3 3 3 25 25 25 25 25 25 254 25 3 SALVAGE AND STORE WHITE DOOR CABINETS FOR T.B.D. LOCATION 3 1 1212 26 6 A.5.1 7 4 5 6 8 1 2 3 KEYED DEMO NOTES 9 DEMOLISH WALL DEMOLISH DOOR, FRAME, & EXT. EGRESS LIGHT - SEE DR. SCHEDULE RE: SALVAGE/REUSE DEMO MOST "DASHED ITEMS" BUT SEE PLANS FOR REUSED ITEMS NOTES 10 DEMOLISH PLUMBING FIXTURE AND OR STONE COPUNTERTOP REMOVE APPLIANCE - SALVAGE FOR OWNER IF APPLICABLE DEMOLISH EXTERIOR STEPS AND/OR RAILINGS - SEE DEMO & FLOOR PLANS DEMOLISH WATER HEATER, MOP SINK, & CAP PLUMBING RETAIN WALL & FLOOR FINISHES TO GREATEST EXTENT POSSIBLE RETAIN CEILING TREATMENT TO GREATEST EXTENT POSSIBLE. GRASSCLOTH MAY BE REMOVED. PROTECT & RETAIN EXISTING WALL UNIT 11 REMOVE HVAC UNIT AND RELOCATE - SEE NEW FLOOR PLAN 12 DEMOLISH EXISTING CEILING TILE & GRID 13 REMOVE EXISTING CERAMIC TILE FLOOR 14 DEMO POCKET DR. & CREATE WD. CASED OPENING. TRIM CROWN FOR NEW WALL CONSTRUCTION 15 REMOVE DOOR & FRAME - REINSTALL IN ADJACENT ALCOVE - SEE NEW PLAN 16 REMOVE FIRE EXSTINGUISHER CABINET - SALVAGE FOR POTENTIAL REUSE 17 REMOVE FIRE EXSTINGUISHER CABINET & RELOCATE AS SHOWN 18 DEMOLISH EXTERIOR SIDEWALK AS NOTED 19 MODIFY CABINETS TO (1) 36" SECTION TO ALLOW A 53"-LONG COPIER. 20 REMOVE CEILING FAN AND SALVAGE FOR USE IN PROGRAM RM 105 21 DEMOLISH TRACK LIGHTING FEATURE 22 DEMOLISH FLOORING IN THIS ROOM AND PREP FOR NEW FLOOR FINISH 23 RELOCATE WATER SHUT-OFF INTO LOCKED METAL CABINET ON WALL 24 RELOCATE DOWNSPOUT AS REQUIRED TO ALLOW SPRINKLER RISER LEAN-TO 25 DEMOLISH LIGHT FIXTURE 26 DEMOLISH WINDOW & PREP FOR REPLACMENT CASED DOOR OPENING N SCALE: 1/8" = 1'-0" 1AS-BUILT & DEMO PLAN A.1.0 PLAN DEMO NOTE #3 CLARIFIED 6-25-26 Page 18 of 69 A R CH ITECT S A R CH ITECT S parkerdesigngrouparchitects 843 785 5171 POST OFFICE BOX 5010 HILTON HEAD ISLAND SC 29938 A facility upfit for: Hilton Head Island, South Carolina Memory MaƩers REVISIONS DATE DATE OF ISSUE: SHEET SGK SCALE DRAWN BY CHECKED BY JOB NO. These documents & designs are the property of Parker Design Group|Architects & are not to be used or reproduced there of or for designs, working drawings, or construction of buildings without the written authorization from the copyright owner PDG|Architects 2025 copyright C 2546 @ 15 Trellis Court FOR FINAL STATE REVIEW A.1.1 FIRST FLOOR PLAN & WALL TYPES 7/27/2026 WTP DPH PROJECT #1016806 101 102 103104 106 108 109A 109B 111 112 113 114 116 118 117 123A 123B 123C 123D 125 128 129 130 135 138 105 127 141 F DW 7 A.3.0 7 A.3.0 2 A.3.0 3 A.3.1 11 A.5.0 6'-6" 8'-6"2'-0" 4'-8" 4'-1" 12'-0 1/2" 11'-0 1/2" 8'-11 1/2" 8'-11" 5'-9" 2'-11 1/2" 5'-9" 24'-0" 11'-11" 7'-8" 5'-6" 24'-0" 11'-3 3/4" 5'-6" 24'-0" 9'-0" 12'-4" 3" 1'-6"3" 1'-4" 1'-4" 1'-6" 3"1'-6" 1'-6" 24'-3" CANOPY 29'-6" CANOPY 9'-7" CANOPY 3" 15'-4" 1'-5" 7'-1 1/2" 6'-11" 7'-11" 11'-7" 3 1/2" 2'-7" 6'-8" 6'-8" 3'-9 1/2" 3'-10" 7'-1" 8" 7'-9 1/2" 4 1/2" 4'-3 1/2" 3-5" CLEAR 4'-0" RAMP 8'-1" 3'-0" 3'-5 1/2" 11'-6" 16'-0" 7'-3" 5'-0" 5'-0" 8'-0" 8'-8" 8'-8" 8'-8" 6 7/16" 7'-4" 7'-4" 7'-4" 26'-4" EDGE OF SECOND CANOPY 8'-8" TO OTHER EDGE 17'-10 1/2" ICE DN BUFFET 1:12 RAMP DOWN TO SENSORY GARDEN OFFICE 129 OFFICE 130 FLEX WORKSPACE 128 LAUNDRY & JAN 127 OFFICE 135 CLASSROOM 123 23'-0" X 22'-0" STAFF COFFEE 121 GUEST & PATIENT R.R. 126 STAFF R.R. ADA 120 ELEC. ELEC. BULLETIN BOARD PASS- THRU SERVING COUNTERSTOR. MUSIC ROOM 116 20'-0" X 15'-7" GARDEN ENTRY FENCE - SEE LANDSCAPE GENERAL PROGRAM AREA 105 42'-0" X 26'-4" DAYCARE ENTRANCE 101 15'-2" X 19'-4" W.I.C. PROGRAM STORAGE 106 OFFICE 138 BRAIN GAME ROOM 104 22'-4" X 15'-2" LOCKED MEDS. CAB. LOCKED FIRST AID ETC. RESTING RM 118 DOOR BETWEEN THE TWO "ZONES" OF THE BUIDLING CABINETS ANTE ROOM 125 ANTE ROOM 113 STOR. FROM DEDICATED CATERING PARKING CONFERENCE 133 R.R. 102 19'-4" X 19'-1" 4'-0"x8'-0" CASED OPENING 5'-6" x 8'-0" CASED OPENING ALIGN WALL AT NORTH EDGE OF EXIS. BEAM EXIST. CASED OPENING EMPLOYEE COATS STOR DISPLAY AREA RECEPTIONIST 136 ALCOVE 139 ALCOVE 132 HOSPITALITY ANTE ROOM 115 STACKED W/D DESK & DISPLAY FOUR SEASONS ROOM 108 COPIER BY OTHERS BENCHBENCH STACKED LOCKERS TBD, TYPICAL DW NEW REFRIG HEATED CABINET PANTRY CATERING STYLE KITCHEN 109 17'-0" X 22'-0" SUPPLIES CHECK-IN COMPUTER ON MOBILE STAND TV ON WALL ICE SERVER CLOSET STORAGE T.B.D. REUSE SALVAGED UPPER & LOWER WHITE CABINETS W/ NEW SINK & COUNTER REUSED WOOD FILE CABINETS WITH SLAB ON TOP PER INTERIORS HANDRAILS TYPICAL IN CORRIDORS HANDRAILS TYPICAL IN CORRIDORS CL COVERED PORCH EXISTING CONCRETE MATCH EXSITING LEVEL B B A A A A A A C A AA A B B A A A A A A A A B A A A A A C A A A A A A A BUILDING SECTION BUILDING SECTION PATTY'S SENSORY GARDEN - SEE LANDSCAPING R.R. 103 BREEZEWAY 107 ANTE ROOM 110 CORR. 119 CORR. 117 CORR. 122 CORR. 124 CORR. 137 LOBBY 140 RELOCATED FRENCH DRS. CASED OPENING 6'-0"x8'-0" CAP END OF ACCOUSTIC FEATURE WITH GYP BD. PER INTERIORS CAP END OF ACCOUSTIC FEATURE WITH GYP BD. PER INTERIORS REUSE SALVAGED "HUTCH" HERE, ON COUNTER 1 A.5.0 5 A.5.0 8 A.5.0 ADD 3 GRAB BARS TO EXIST RESTROOM CL ADD VERTICAL GRAB BAR BB B B B B B B BBBB C A A NEW FREEZ RELOCATED HVAC UNITS ON CONCRETE PAD +/- 12'-0 MSL EXISTING METERS EXISTING HVAC UNIT NEW ROOF LADDER SPRINKLER LEAN-TO 141 A RISERS NEW STAIR GATE WITH LATCH BUILDING SETBACK LINE A C RAILING ON WALL CABLE RAILING SYSTEM - SEE EXT. ELEVATION REUSE SALVAGED WALL UNIT (WITH 6 LOWER DOORS) HERE ELECTRIC DOOR OPENER ELECTRIC DOOR OPENER ON POST ALIGN WALL AT NORTH EDGE OF EXIS. BEAM REPLACE FIXTURES NEW MOP SINK W/ FRP 3'-0"H ON WALLS SIGNAL SYSTEM FOR CALL BUTTONS; CAMERA DISPLAYS A WH ART ROOM 111 7'-0" H FENCE PER OWNER. SEE EXTERIOR ELEVATIONS NEW HVAC UNITS ON CONCRETE PAD +/- 12'-0 MSL FENCE & GATE W/ ELECTRONIC BYPASS - SEE LANDSCAPE LOCKED WALL CABINET FOR CHEMICALS PULL CORD PULL CORD REPLACE RANGE HANDICAP SPACE 4 A.5.1 (4) 5 1/2" RISERS (3) 18" TREADS 1 A.5.1 CONCRETE BOLLARD CONCRETE BOLLARD CANOPY CANOPY CASED OPENING 7'-6"x +/-9'-0"SECRETARY DESK SELECTED BY INTERIORS 109D 139 126 119A 119B 120A 120B 109C 10'-7" 10'-4 1/2" 5'-3 1/2" 9'-1 3/4" 13'-5" 9'-2" CANOPY 5'-0" OFFICE 131 OFFICE 134 R.R. 114 19'-4" X 19'-4" HANDRAILS TYPICAL IN CORRIDORS 7''-0" RAMP @1:12 LANDING 13.4 NEW CONC. 14.2 10'-0" RAMP @1:12 CONNECTION CONCRETE SLOPES FROM 14.2 TO 14.1 FLAT CONCRETE @ 12.8 BENCH BENCH 5'-0"X6'-0" FLAT 12.7 BENCH B A CANOPIED WALKWAYS MIMIC THE EXISTING CONCRETE BORDERS ON NEW CONCRETE WALKS & RAMPS, TYP. EXISTING PLANTER - NO NEW WORK EXTEND LANDSCAPE CURB AS REQUIRED DONOR PLAQUE TBD C.J.C.J. C.J. FLAT CONCRETE @ 12.8 CANOPY LIGHT, TYP. - SEE ELEC. TYPE INT. WALLB 1/2" GYPSUM BOARD TYPICAL TYP. 2X4 STUDS @ 16".O.C. WALL KEY AND DETAILS TYPE INT. WALLA 1/2" GYPSUM BOARD TYPICAL TYP. 2X4 STUDS @ 16".O.C. 1/2" GYPSUM BOARD ON BOTTOM OF JOISTS -OR- OPEN - SEE RCP 3" MINERAL WOOL SOUND INSULATION TYPE INT. WALLC 1/2" GYPSUM BOARD TYPICAL TYP. 2X6 STUDS @ 16".O.C. 3" MIN. MINERAL WOOL SOUND INSULATION 1/2" GYPSUM BOARD ON BOTTOM OF JOISTS -OR- OPEN - SEE RCP 1/2" GYPSUM BOARD ON BOTTOM OF JOISTS -OR- OPEN - SEE RCP 1,104 SF DAY CARE PROGRAM SPACES GENERAL PROGRAM SPACE 1,134 MUSIC, ART, & BRAIN GAMES 576 DINING/SOCIALIZATION 2,814 SF DAY CARE SUPPORT SPACES RESTING ROOM 210 REST ROOMS & SHOWER 281 CATERING KITCHEN 418 STORAGE 88 1,061 SQR. FOOTAGE USE SF BUSINESS SPACES 552 SF BUSINESS SPACES CLASSROOM 1,324 1,734 410 OFFICES CONFERENCE JANITOR/LAUNDRY 64 SF BUSINESS SUPPORT 249 COFFEE / REST RM / IT STORAGE SPRINKLER RM 101 35 385 SF CIRCULATION DAYCARE CIRCULATION 828 BUSINESS CIRCULATION 1,317 2,145 SF TOTALS DAYCARE TOTAL SF 4,564 BUSINESS TOTAL SF 4,015 8,579 BUILDING TOTAL SF N SCALE: 1/8" = 1'-0" 1PROPOSED 1ST FLOOR PLAN A.1.1 PLAN Page 19 of 69 A R CH ITECT S A R CH ITECT S parkerdesigngrouparchitects 843 785 5171 POST OFFICE BOX 5010 HILTON HEAD ISLAND SC 29938 A facility upfit for: Hilton Head Island, South Carolina Memory MaƩers REVISIONS DATE DATE OF ISSUE: SHEET SGK SCALE DRAWN BY CHECKED BY JOB NO. These documents & designs are the property of Parker Design Group|Architects & are not to be used or reproduced there of or for designs, working drawings, or construction of buildings without the written authorization from the copyright owner PDG|Architects 2025 copyright C 2546 @ 15 Trellis Court FOR FINAL STATE REVIEW A.1.2 REFLECTED CEILING PLAN 7/27/2026 WTP DPH PROJECT #1016806 GUEST & SENIOR R.R. ADA 18'-8" BUFFET LAUNDRY & JAN OFFICE CLASSROOM STAFF COFFEE STAFF R.R. ADA STOR. MUSIC ROOM ART ROOM GENERAL PROGRAM AREA W.I.C. PROGRAM STORAGEOFFICE BRAIN GAME ROOM RESTING RM ANTE ROOM ANTE ROOM STOR. CONFERENCE ENTRANCE 1 RECEPTIONIST FOUR SEASONS ROOM COPIER BY OTHERS CATERING STYLE KITCHEN SUPPLIES SERVER CLOSET CL COVERED PORCH FLEX OFFICE GYP. BD. @ 15'-10" AFF OPEN TO ROOF DECK OPEN TO ROOF DECK GYP. BD. @ 8'-6" AFF GYP. BD. @ 9'-8" SALVAGE ACT @ 9'-8" AFF SALVAGE ACT @ 9'-8" AFF SALVAGE ACT @ 9'-8" AFF SALVAGE ACT @ 9'-8" AFF GYP. BD. @ 10'-0" AFF ACT @ 10'-0" AFF PATCH EXISTING EXISTING EXISTING EXISTING CEILING TO REMAIN EXISTING CEILING TO REMAIN BEVERAGES STOR. EXISTING EXISTING DISPLAY AREA ALCOVE ACT-1 @ 11'-0" AFF GYP. BD. @ 9'-8" AFF DAYCARE ENTRANCE SALVAGE EXISTING CEILING TO REMAIN ARMSTRONG "KITCHEN ZONE" ACT @ 8'-0" AFF ACT-1 @ 8'-6" AFF GYP. BD. HEADER AT 9'-11" AFF ANTE ROOM ANTE ROOM SALVAGE ACT @ 9'-8" AFF WP OPEN TO ROOF DECK STOR. OPEN TO ROOF DECK EXISTING CEILING TO REMAIN OFFICE EXIS. SMALL DIRECTIONAL CAN LIGHTS EXIS. SMALL DIRECTIONAL CAN LIGHTS OFFICE OFFICE EXISTING LIGHTS & CEILING TO REMAIN EXISTING LIGHTS & CEILING TO REMAIN EXISTING CEILING TO REMAIN EXISTING CEILING TO REMAIN GYP. BD. @ 9'-8" AFF EF EF EF EF EF EF EF S/C D S/C D FEC EXIT SIGN EXIT SIGN EXIT/ EMER SIGN EXIT/ EMER SIGN EXIT/ EMER SIGN FEC FEC FEC EXIT/ EMER SIGN EXIT/ EMER SIGN EXIT/ EMER SIGN FEC S/C D S/C D S/C D S/C D S/C D S/C D S/C D S/C D S/C D S/C D S/C D S/C D S/C D S/C D EXISTING CEILING TO REMAIN EXISTING CEILING TO REMAIN EXISTING CEILING TO REMAIN EXISTING CEILING TO REMAIN EXISTING CEILING TO REMAIN EXISTING CEILING TO REMAIN EXIT/ EMER SIGN EXIT/ EMER SIGN EXIT/ EMER SIGN EXISTING CEILING TO REMAIN EXISTING CEILING TO REMAIN CL NEW GYP. BD. CEILING 9'-8" AFF EXTERIOR EXIT/EMERG. LIGHT EXTERIOR EXIT/EMERG. LIGHT EXTERIOR EXIT/EMERG. LIGHT ALCOVE EXISTING CEILING TO REMAIN EXIT/ EMER SIGN GYP. BD. @ 9'-8" GYP. BD. @ 9'-8" ELEC. ELEC. EXIT/ EMER SIGN EMER LIGHT EMER LIGHT EMER LIGHT EXIT/ EMER SIGN EXIT/ EMER SIGN EXISTING CEILING TO REMAIN WALL-MOUNTED FIRE-ALARM ANNUCIATOR PANEL NEW EXTERIOR CAN LIGHT NEW FLOOD LIGHT IN EXIS. JUNCTION BOX - 6'-8" AFF MIN. (A.D.A.) EXTERIOR EXIT/EMERG. LIGHT NEW FLOOD LIGHT IN EXIS. JUNCTION BOX NEW STELLA OUTDOOR FLOOD LIGHT ON SAME CIRCUIT AS ADJACENT FLOOD LIGHTS OFFICE PASS- THRU SERVING COUNTER RESTROOM RESTROOM RESTROOM RESTROOM SYMBOL KEY 3" x 48" PENDENT-MOUNTED LED LIGHT WALL SCONCE PENDANT CAN LIGHT 24"x24" LED LIGHT FIXTURE CEILING FAN DEMOLISHED LIGHT (DASHED) EMERGENCY LIGHT EXIT SIGN EMERGENCY & EXIT LIGHT TRACK LIGHTING SUPPLY DIFFUSER RETURN AIR GRILLE S/C D EXHAUST FAN COMBINATION SMOKE/ CARBON MONOXIDE DETECTOR EXTERIOR FLOOD LIGHT SELECTED BY ARCHITECT EXTERIOR CANOPY LIGHT SELECTED BY ARCHITECT GENERAL CEILING NOTES 1. THE SPRINKLER SYSTEM AND FIRE ALARM SYSTEM WILL BE DESIGNED BY OTHERS, UTILIZING INTERNATIONAL FIRE CODE 2021 W/ SOUTH CAROLINA AMENDMENTS, AFTER STATE & LOCAL FINAL APPROVAL OF PLANS. 2. THE STATE OF CAROLINA AND THE TOWN OF HILTON HEAD ISLAND RESERVE THE RIGHT TO REQUIRE CHANGES TO THE SPRINKLER SYSTEM AND FIRE ALARM SYSTEM DESIGNS. 3. THE MEMORY MATTER FACILITY SHALL HAVE AN ALARM SYSTEM THAT INCLUDES SMOKE DETECTION IN ALL MAIN AREAS, AND PULL STATIONS THROUGHOUT THE BUILDING, ALL SUPERVISED BY THE FIRE ALARM SYSTEM. 4. MEMORY MATTERS SHALL ENSURE THE ALARM SYSTEM IS ARRANGED TO TRANSMIT AN ALARM AUTOMATICALLY TO A THIRD PARTY BY AN APPROVED METHOD. 5. MEMORY MATTERS SHALL ENSURE THE ALARM SYSTEM NOTIFIES BY AUDIBLE AND VISUAL ALARM ALL AREAS AND FLOORS OF THE BUILDING. 6. MEMORY MATTERS SHALL ENSURE THE ALARM SYSTEM SHUTS DOWN CENTRAL RECIRCULATING SYSTEMS AND OUTSIDE AIR UNITS THAT SERVE THE AREA(S) OF ALARM ORIGINATION, AS A MINIMUM. 7. THE FIRE ALARM SYSTEM SHALL ENSURE THAT NO SMOKE DETECTOR IS LESS THAN 3'-0" AWAY FROM HVAC SUPPLY & RETURN VENTS OR THE FAN-TIPS OF A CEILING FAN. SCALE: 1/8" = 1'-0" 1REFLECTED CEILING PLAN A.1.2 Page 20 of 69 A R CH ITECT S A R CH ITECT S parkerdesigngrouparchitects 843 785 5171 POST OFFICE BOX 5010 HILTON HEAD ISLAND SC 29938 A facility upfit for: Hilton Head Island, South Carolina Memory MaƩers REVISIONS DATE DATE OF ISSUE: SHEET SGK SCALE DRAWN BY CHECKED BY JOB NO. These documents & designs are the property of Parker Design Group|Architects & are not to be used or reproduced there of or for designs, working drawings, or construction of buildings without the written authorization from the copyright owner PDG|Architects 2025 copyright C 2546 @ 15 Trellis Court FOR FINAL STATE REVIEW A.1.3 SCHEDULES & DOOR/ WINDOW TYPES 7/27/2026 WTP DPH PROJECT #1016806 8'-0" SEE SCHED 8'-0" 6'-0" 8'-0" SEE SCHED 5'-0" 3'-0" 8'-0" 7'-0" SEE SCHED HARDWARE SCHEDULE MARK REMARKSMFG. & STYLETYPE 1 MFG. NUMBER NOTES: 1. SUBMIT FULL HARDWARE SCHEDULE FOR REVIEW 2. ALL FINISHES TO MATCH EXISTING COLOR HARDWARE 3. ALL EXISTING KNOBS REPLACED WITH LEVERS DOOR & FRAME ELEVATION KEYS TYPE 3TYPE 1 2 SCHLAGE LATITUDE FB50LAT622 4 DSP-3 SCHLAGE LATITUDESCHLAGE LATITUDE SCHLAGE LATITUDE PASSAGE LEVER DOUBLE-SWING 3 ELIASON EASY SWING HINGE 101 102 FRAME DOOR Material / Finish Type REMARKSSizeMARK FIRE RATING TW H DOOR & FRAME SCHEDULE NA HARD- WARE MARK NA NA EXIST NA 103 NA WOOD NA NA NA 104 105 112 114 118 119A 125 NA EXIST NA NA NA NA NA NA NA ADD AUTOMATIC OPENERS TO DOORS VIA EXTERIOR BUTTON ON PEDESTAL AND VIA INTERIOR WALL BUTTON 1 EXISTEXIST/PAINT 5 1 1 REPLACE LEVER AND DEADBOLT 8'-0" 1 3/4" 8'-0"3'-0" 1 3/4" 8'-0"3'-0" 1 3/4" 8'-0"2'-8" 1 3/4" 8'-0"3'-0" 1 3/4" 8'-0"3'-0" 1 3/4" 1 EXIST EXIST EXIST EXIST EXIST EXIST WOOD NA WOOD NA WOOD NA WOOD NA NA WOOD NA1 WOOD NA1 WOOD NA1 WOOD NA1 NA 6 2 DUMMY LEVERS W/ ROLLER CATCH AT TOP EXIST/PAINT EXIST EXIST 8'-0"3'-0" 1 3/4" 2-PANEL SMOOTH TO MATCH EXISTING FULL-LITE SMOOTH TO MATCH EXISTING 1WOOD/PAINT PRIVACY LEVER LOCK FB51LAT622 F10LAT622 ENTRY LEVER LOCK W/ DEADBOLT NO HANDLE HARDWARE WOOD18'-0"3'-0" 1 3/4" 1WOOD/PAINT WOOD28'-0" 1 3/4" 2WOOD/PAINT3'-0" TYPE 2 FULL-LITE SMOOTH TO MATCH EXISTING WOOD8'-0" 1 3/4" 3WOOD/PAINT2X(3'-0") PUSH & PULLS W/ CLOSERS 3 106 WOOD28'-0" 1 3/4" 2WOOD/PAINT3'-0" 108 WOOD28'-0" 1 3/4" 2WOOD/PAINT3'-0" 109A 109B 109C 8'-0"3'-0" 8'-0"3'-0" STAINLESS STEEL STAINLESS STEEL TYPE 4 ELIASON DSP-3 STAINLESS STEEL 16 GA. DOOR W/ EASY SWING HINGE WOOD CASED OPENING FRAME16 GA. 16 GA. 4 4 4 4 WOOD WOOD WOOD CASED OPENING FRAME DUMMY LEVER F170LAT622 ROLLER CATCHES AT TOP SCHLAGE LATITUDE 5 6 111 WOOD28'-0" 1 3/4" 2WOOD/PAINT3'-0" NAWOOD8'-0"3'-0" 1 3/4" 1WOOD/PAINT NAWOOD8'-0"3'-0" 1 3/4" 1WOOD/PAINT 116 NAWOOD28'-0" 1 3/4" 2WOOD/PAINT3'-0" 117 WOOD28'-0" 1 3/4" 2WOOD/PAINT3'-0" WOOD28'-0" 1 3/4" 2WOOD/PAINT3'-0" WOOD18'-0" 1 3/4" 2WOOD/PAINT3'-0" 123A WOOD28'-0" 1 3/4" 2WOOD/PAINT3'-0" 123B 123C 123D 22WOOD/PAINT 2X(1'-8") 2X(1'-8") 8'-0" 1 3/4" WOOD/PAINT WOOD/PAINT 1 WOOD6 2 DUMMY LEVERS W/ ROLLER CATCH AT TOP 22WOOD/PAINT 126 WOOD18'-0"3'-0" 1 3/4" 1WOOD/PAINT 127 2WOOD/PAINT 8'-0"3'-0" 1 3/4"128 WOOD12WOOD/PAINT 129 130 WOOD/PAINT 2 135 WOOD/PAINT 2 138 139 RELOCATED ADJACENT FR. DOOR PAIR INTO REDUCED-WIDTH FRAME W/4 DUMMY LEVERS W/ ROLLER CATCH AT TOP EXISTEXIST 2X(2'-0") EXIST EXIST EXIST 1 WOOD NA 119B EXIST EXISTEXISTEXIST EXIST EXIST/PAINT 4 DUMMY LEVERS REPLACE KNOBS NA 1 120A EXIST EXISTEXISTEXIST EXIST NA 120B EXIST EXISTEXISTEXIST EXIST NA EXIST/PAINT EXIST/PAINT 2 2 6 PRIVACY LEVERS REPLACE KNOBS PRIVACY LEVERS REPLACE KNOBS PRIVACY LEVERS REPLACE KNOBS ON REPURPOSED DOOR PRIVACY LEVERS REPLACE KNOBS ON REPURPOSED DOOREXIST EXISTEXIST EXIST EXIST/PAINT EXIST EXISTEXIST EXIST EXIST/PAINT TYPE 5 INSULATED METAL DOOR 141 8'-0" 1 3/4" METAL NAMETAL/PAINT 15 NA109D 7'-0"3'-0" WOOD1 3/4" WOOD/PAINT 1 2 2X(3'-0") FINISH SCHEDULE Base HeightFinishMaterialFinishMaterialMaterial WALLFLOOR CEILINGROOM NAME PT-1DAYCARE ENTRANCE 11'-3"EXIST/ MATCH EXISTING PT-3 NOTES: U.N.O. TYPICAL WALL BASE IS PAINT-GRADE 1X6 W/NOSING ON TOP TO MATCH EXISTING SHEET VINYL W/ COVED EDGES AS SELECTED BY INTERIOR DESIGNER LVP: CORETEC LVP AS SELECTED BY INTERIOR DESIGNER T-1: WHITE WATERCOLOR SUBWAY 3X12 TILE, BF CERAMICS, PLACE FROM FLOOR UP TO 4'-0 AFF W/ GROUT AS SELECTED BY INTERIOR DESIGNER PT-1: 2 COATS MINIMUM, SHERWIN WILLIAMS SW7008 ALABASTER, EGGSHELL PT-2: 2 COATS MINIMUM, SHERWIN WILLIAMS SW7008 ALABASTER, SATIN PT-3: 2 COATS MINIMUM, SHERWIN WILLIAMS SW7008 ALABASTER, FLAT PT-4: 2 COATS MINIMUM, SHERWIN WILLIAMS SW6533 MILD BLUE, EGGSHELL PT-5: 2 COATS MINIMUM, SHERWIN WILLIAMS SW6204 SEA SALT, EGGSHELL PT-6: 2 COATS MINIMUM, SHERWIN WILLIAMS SW7029 AGREEABLE GRAY, EGGSHELL PT-7: 2 COATS MINIMUM, SHERWIN WILLIAMS SW6246 NORTH STAR, EGGSHELL PT-8: 2 COATS MINIMUM, SHERWIN WILLIAMS SW6247 KRYPTON, EGGSHELL PT-9: 2 COATS MINIMUM, SHERWIN WILLAIMS SW6520 HONEST BLUE, FLAT SHERWIN WILLIAMS PRIMER ON UNFINISHED WOOD AND UNFINISHED GYPSUM BOARD SHEET VINYL: TARKETT IQ OPTIMA WITH COVED EDGES AND HEAT-WELDED SEAMS ROOM # 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 RESTROOM BRAIN GAMES WALK-IN STORAGE BREEZEWAY FOUR SEASONS CATERING KITCHEN ART ROOM OFFICE PT-4 / T-1 9'-0"GYP. BD. PT-3GYP. BD. PT-3 PT-5 11'-0"MFR PT-1 9'-8" PT-9 EXIS ACTPT-1 VARIES PT-1 10'-0"PT-3 PT-6 15'-10"PT-3 PT-2 8'-0" "KITCHEN-ZONE" ACT MFR. PT-1 PT-3 PT-1 9'-8"PT-3 PT-3 PT-3 PT-3 PT-3 PT-3 PT-9 PT-1 PT-7 PT-7 PT-1 PT-7 PT-1 PT-1 PT-1 LVP LVP LVP LVP LVP SHEET VINYL COVED VINYL LVP LVP 6"-HIGH T-1 LVP LVP LVP LVP LVP LVP LVP LVP EXIST/GYP.BD. RESTROOM GYP. BD.GYP. BD.6"-HIGH T-1 9'-0" EXIST/ MATCH EXIST/GYP.BD. EXIST/ MATCH EXIST/GYP.BD. GYP.BD. GENERAL PROGRAM EXISTING GYP BD TYPICAL GYP.BD. GYP BD EXIST/GYP.BD. LVP EXIST/GYP.BD. EXIST/OPEN ACT-1 EXIST/GYP.BD. TYPICAL EXIST/ MATCH EXIST/ MATCH EXIST/OPEN VARIES 8'-6"ACT-1ANTE ROOM TYPICAL GYP.BD. 8'-6"GYP. BD. PT-3GYP. BD.6"-HIGH T-1RESTROOM 9'-8"GYP. BD. PT-3GYP. BD.6"-HIGH T-1RESTROOM ANTE ROOM TYPICAL EXIST/GYP.BD. GYP. BD. ANTE ROOM TYPICAL EXIST/GYP.BD. GYP. BD. 9'-8" MUSIC ROOM EXIST/ MATCH EXIST/GYP.BD. SALVAGE ACT-1 9'-8" CORRIDOR TYPICAL EXIST/GYP.BD. SALVAGE ACT-1 9'-8" SALVAGE ACT-1 9'-8" MFR. MFR. MFR. MFR.RESTING ROOM EXIST/ MATCH EXIST/GYP.BD. CORRIDOR PT-1LVP EXIST/ MATCH EXIST/GYP.BD. 8'-11"EXIS ACTEXISTING RESTROOM EXISTING EXISTINGGYP. BD.6"-HIGH T-1 STAFF COFFEE EXIST/ MATCH EXIST/GYP.BD. EXISTING EXISTING CORRIDOR EXIST/ MATCH EXIST/GYP.BD. EXISTING EXISTING CLASSROOM EXIST/ MATCH EXIST/GYP.BD. EXISTING EXISTING EXIS ACT 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 PT-1LVPCORRIDOR EXIST/ MATCH EXIST/GYP.BD. EXISTING EXISTINGEXIS ACT PT-1LVPANTE ROOM EXIST/GYP.BD.EXIST/ MATCH EXISTINGEXIS ACT EXIST/GYP.BD.RESTROOM 6"-HIGH T-1 PT-3EXISTING EXISTING JANITOR/'LAUNDRY PT-1LVP EXIST/GYP.BD.EXIST/ MATCH PT-3EXISTING EXISTING FLEX WORKSPACE PT-6LVP EXIST/GYP.BD.EXIST/ MATCH EXISTING EXISTINGMATCH EXIST. PT-1LVP EXIST/GYP.BD.EXIST/ MATCH EXISTING EXISTINGMATCH EXIST. OFFICE OFFICE PT-1LVP EXIST/GYP.BD.EXIST/ MATCH EXISTING EXISTING PT-1LVP EXIST/GYP.BD.EXIST/ MATCH EXISTING EXISTING ALCOVE LVP EXISTING EXISTING PT-1 PT-3EXISTING EXISTING PT-3 PT-3 CONFERENCE ROOM LVP EXISTING EXISTING PT-8 PT-3EXISTING EXISTING OFFICE PT-1LVP EXIST/GYP.BD.EXIST/ MATCH EXISTING EXISTINGPT-3 OFFICE PT-1LVP EXIST/GYP.BD.EXIST/ MATCH EXISTING EXISTINGPT-3 RECEPTIONIST PT-7LVP EXIST/GYP.BD.EXIST/ MATCH EXISTING EXISTINGPT-3 LVPCORRIDOR EXISTING EXISTING PT-1 EXISTING EXISTINGEXIS ACT EXISTING OFFICE PT-1LVP EXIST/GYP.BD.EXIST/ MATCH EXISTING EXISTINGEXIS ACT ALCOVE LVP PT-1EXIST/GYP.BD.EXIST/ MATCH EXISTING EXISTINGPT-3 LOBBY LVP PT-8EXIST/GYP.BD.EXIST/ MATCH EXISTING EXISTINGPT-3 141 SPRINKLER RISER RM CONCRETE PT-1GYP.BD.EXIST/ MATCH OPEN VARIESPT-3 LVP LVP LVP LVP LVP LVP TRIM Finish PT-2 PT-2 PT-2 PT-2 PT-2 PT-2 PT-2 PT-2 PT-2 PT-2 PT-2 PT-2 PT-2 PT-2 PT-2 PT-2 PT-2 PT-2 PT-2 PT-2 PT-2 PT-2 PT-2 PT-2 PT-2 PT-2 PT-2 PT-2 PT-2 PT-2 PT-2 PT-2 PT-2 PT-2 PT-2 PT-2 PT-2 PT-2 PT-2 PT-2 PT-2 PT-4 / T-1 PT-4 / T-1 PT-4 / T-1 PT-4 / T-1 PT-4 / T-1 PAN FLASHING IN SEALANT HEAD SILL SILL BELOW FLYASH 5/4 X 4 TRIM 5/4 X 4 TRIM CONCEALED FLASHING CONCEALED FLASHING TR. 2 X 4 DRIP CUT @ 15 DEGREE ANGLE CONCEALED FLASHING JAMB 5/4x4 FLYASH TRIM 1/2"PLYWOOD SHEATHING TYP. SIDING EXPOSED CAP FLASHING 1 1/2"X 2 1/2" FLYASH DRIP CAP 8'-8" 4'-9" 6'-0" 4'-9" 3'-0" 3'-0" 6'-0" 4'-0" 3'-0" 2'-8" 5'-0" 3'-4" 3'-0" MARK B WINDOW MARK A WINDOW MARK C WINDOW MARK D WINDOW 4'-9" X 6'-0" 4'-9" X 8'-8" A B ROUGH OPENING SIZEMARK TYPE WINDOW SCHEDULE 1. SIERRA PACIFIC WOOD WINDOWS W/ ARGON FILLED, LOW-E GLASS, 5/8" SDL, & IMPACT GLASS - COLOR TO MATCH EXISTING - SEE ELEVATIONS FOR LITE PATTERN INCLUDES 2'-8" TRANSOMCASEMENT W/TRANSOM CASEMENT 4'-0" X 6'-0"C CASEMENT 3'-4" X 5'-0"D CASEMENT SCALE: 1 1/2"= 1'-0" 2WINDOW DETAILS A.1.3 SCALE: 1/4" = 1'-0" 1WINDOW ELEVATIONS A.1.3 Page 21 of 69 A R CH ITECT S A R CH ITECT S parkerdesigngrouparchitects 843 785 5171 POST OFFICE BOX 5010 HILTON HEAD ISLAND SC 29938 A facility upfit for: Hilton Head Island, South Carolina Memory MaƩers REVISIONS DATE DATE OF ISSUE: SHEET SGK SCALE DRAWN BY CHECKED BY JOB NO. These documents & designs are the property of Parker Design Group|Architects & are not to be used or reproduced there of or for designs, working drawings, or construction of buildings without the written authorization from the copyright owner PDG|Architects 2025 copyright C 2546 @ 15 Trellis Court FOR FINAL STATE REVIEW A.1.4 FURNITURE PLAN 7/27/2026 WTP DPH PROJECT #1016806 DCB48 B36 B36 B36 B36 B8115 B36 B36 DCB48 B36 B36 B36 B36 B8115 B36 B36 101 102 103 104 105 106 107 108 109 FOUR SEASONS ROOM 110 111 112 ART ROOMMUSIC ROOM 113 114 115 116 CORR. 117 118 119 120 CORR. 122 CLASS ROOM 123 124 125 126127 128 129 130 OFFICE 131 132 134 CONFERENCE 135 136 138 CORR. 136 139 140 ENTRANCE LOBBY 141 SPRINKLER RISER Room # Room Furniture 101 Daycare Entrance Lockers - Custom Integrity Cabinetry Benches - Lexington Abbott Benches Chest - Sunset Key Kenan Hall 102 Restroom N/A 103 Restroom N/A 104 Brain Games Existing Tables and Chairs 105 General Program Existing Tables and Chairs 106 Walk In Storage N/A 107 Breezeway N/A 108 Four Seasons Existing Tables and Chairs 109 Catering Kitchen N/A 110 Ante Room N/A 111 Art Room Existing Tables and Chairs 112 Restroom N/A 113 Ante Room N/A 114 Restroom N/A 115 Ante Room N/A 116 Music Room Existing Tables and Chairs 117 Corridor N/A 118 Resting Room Pottery Barn Secretary Desk 119 Corridor N/A 120 Restroom N/A 121 Staff Coffee N/A 122 Corridor N/A 123 Classroom Existing Tables and Chairs 124 Corridor N/A 125 Ante Room N/A 126 Restroom N/A 127 Janitor/Laundry N/A 128 Flex Workspace Existing Desk, Chair, File Cabinet 129 Office Existing Desk, Chair, File Cabinet 130 Office Existing Desk, Chair, File Cabinet 131 Office Existing Desk, Chair, File Cabinet 132 Alcove N/A 133 Conference Room Conference Table - Theodore Alexander Gabrielle's Chairs - Hooker Sonora Dining Chair 134 Office Existing Desk, Chair, File Cabinet 135 Office Existing Desk, Chair, File Cabinet 136 Receptionist Existing Desk, Chair, File Cabinet 137 Corridor 2 Console Tables - Century Cadence SCALE: 1/8" = 1'-0" 1FURNITURE PLAN A.1.4 FURNITURE LIST Page 22 of 69 A R CH ITECT S A R CH ITECT S parkerdesigngrouparchitects 843 785 5171 POST OFFICE BOX 5010 HILTON HEAD ISLAND SC 29938 A facility upfit for: Hilton Head Island, South Carolina Memory MaƩers REVISIONS DATE DATE OF ISSUE: SHEET SGK SCALE DRAWN BY CHECKED BY JOB NO. These documents & designs are the property of Parker Design Group|Architects & are not to be used or reproduced there of or for designs, working drawings, or construction of buildings without the written authorization from the copyright owner PDG|Architects 2025 copyright C 2546 @ 15 Trellis Court FOR FINAL STATE REVIEW A.2.0 EXTERIOR ELEVATIONS 7/27/2026 WTP DPH PROJECT #1016806 4-SEASON ROOM ADDITIONEXISTING BUILDING 2'-0" MIN. @ BUS DROP-OFF 1'-0" TYP. 14'-0" MSL - T.O. FLOOR BREEZEWAY ADDITION 7 12 7 12 B B B BC 1'-0" TYP. 10'-0" RAMP @ 1:12 SLOPE 7'-0" RAMP @ 1:12 SLOPE 3 12 24'-0" 4-SEASON ROOM ADDITION EXISTING BUILDING 10'-0" 8'-1" SPRINKLER RM. 9'-6" 25'-0" LONG 1:12 CONCRETE RAMP - BROOM FINISH EQ. EQ. EQ. EQ. 7'-0" 6'-8" MIN. (A.D.A) 6'-8" MIN. (A.D.A.) 6'-8" MIN. (A.D.A) 14'-0" MSL - T.O. FLOOR NEW KITCHEN DOOR EXIS. CONCRETE STEPS & COMPLIANT RAILINGS NEW DOWNSPOUT & GUTTER FOR ADDED ROOF NEW WALL, BEYOND - W/ 7" EXPOSURE FLYASH SIDING & FLYASH TRIM ROOF SLOPES AT 1/2" PER FOOT EXIS. CONCRETE STEPS & NEW A.D.A.-COMPLIANT RAILINGS NEW EXIT DOOR WITH REVERSED SWING NEW WINDOW REPLACES FORMER DOOR 4" CONCRETE WALK LEADS TO SENSORY GARDEN 7 12 7 12 B B B B INFILL STUCCO AS REQUIRED METAL ROOF MATCHES EXISTING EXISTING EMERGENCY EGRESS LIGHT DOOR PAINT TO MATCH EXISTING 7/8" STUCCO ON METAL LATH - MATCH EXISTING AS CLOSELY AS POSSIBLE CABLE RAILING SYSTEM COTTERMAN FIXED STEEL LADDER WITH LOCKABLE COTTERMAN LADDER GUARD, OR SIMILAR METAL CANOPIES W/ WIRE TIEBACKS- MITCHELL METALS OR SIMILAR PATCH STUCCO AT REMOVED EGRESS LIGHT NEW STELLA OUTDOOR FLOOD LIGHT IN EXISTING JUNCTION BOX NEW STELLA OUTDOOR FLOOD LIGHT ON SAME CIRCUIT AS ADJACENT FLOOD LIGHTS 9'-0" 12'-4" NEW BREEZEWAY 24'-0" 4-SEASONS ROOM ADDITION EXISTING BUILDING 3'-0" 6'-0" 2'-8" 9'-7" 1'-0" TYP. 11'-0" 2'-6" 2'-0" R 1'-6" TYP. 2'-0" 12'-1" 4'-9" EXISTING STUCCO EXTERIOR FINISH EXISTING METAL ROOF METAL ROOF TO MATCH EXISTING EXISTING CLAD WINDOWS NEW CLAD WINDOWS CLAD WINDOWS TO MATCH EXISTING POLY-ASH TRIM & PILASTERS, TYPICAL POLY-ASH LAP SIDING - 3 1/2" EXPOSURE - TYPICAL FYPON BRACKETS 14'-0" MSL - T.O. FLOOR 10'-0" RAMP @ 1:12 SLOPE7'-0" RAMP @ 1:12 SLOPE CANOPY, POST, & BRACKET COLOR MATCHES STUCCO 7/8" STUCCO ON METAL LATH - MATCH EXISTING AS CLOSELY AS POSSIBLE 7 12 7 12 A A B B BB 1x4 POLY-ASH TRIM & HARDIE PANELS, TYPICAL 7" EXPOSURE FLY-ASH SIDING X A.3.0 UPSIDE INNOVATIONS CANOPIES - SEE PLAN SCALE: 3/16" = 1'-0" 2FRONT (SOUTH) ENTRY ELEVATION A.2.0 SCALE: 3/16" = 1'-0" 3BACK (NORTH) ELEVATION A.2.0 SCALE: 3/16" = 1'-0" 1FOUR-SEASONS ROOM (EAST) ELEVATION A.2.0 Page 23 of 69 A R CH ITECT S A R CH ITECT S parkerdesigngrouparchitects 843 785 5171 POST OFFICE BOX 5010 HILTON HEAD ISLAND SC 29938 A facility upfit for: Hilton Head Island, South Carolina Memory MaƩers REVISIONS DATE DATE OF ISSUE: SHEET SGK SCALE DRAWN BY CHECKED BY JOB NO. These documents & designs are the property of Parker Design Group|Architects & are not to be used or reproduced there of or for designs, working drawings, or construction of buildings without the written authorization from the copyright owner PDG|Architects 2025 copyright C 2546 @ 15 Trellis Court FOR FINAL STATE REVIEW A.3.0 BUILDING & WALL SECTIONS 7/27/2026 WTP DPH PROJECT #1016806 10'-0" 15'-10" 14'-3 1/2" MSL - T.O. FLOOR 7 12 4-SEASONS ROOM PLATE PASS-THROUGH CATERING KITCHEN 7 12 ACOUSTICAL TILE SYSTEM ATTIC MINI-SPLIT SYSTEM BY OTHERS EXISTING BUILDING 4 A.3.0 1 A.3.0 WINDOWS - BEYOND 5 A.3.0 9'-0" 10'-0" 10'-0" 1'-9" 4'-0" 24'-0" 11'-0" 4'-10" 10'-0" COVERED PORCH PLATE PASS-THROUGH BREEZEWAY EDGE OF PILASTER 1X1 OVER 1X12 FLYASH TRIM BOARD FLY-ASH LAP SIDING - 7" EXPOSURE, TYPICAL 1X6 FLY-ASH TRIM BOARDS AT CORNERS AND FRIEZE BAND, TYP. ON THIS PORCH RUN FLASHING UP WALL BEHIND SIDING 2X12 FLY ASH BASE TRIM W/2X4 SILL ON TOP FLY-ASH LAP SIDING - 7" EXPOSURE, TYPICAL 1X6 FLY-ASH TRIM BOARDS TYPICAL METAL ROOF & ROOF TRIM WALL BLOCKING AT PLYWOOD SEAMS 3 A.3.0 1 12 7 12 7 12 ACOUSTICAL TILE SYSTEM 14'-3 1/2" MSL - T.O. FLOOR EXISTING CONCRETE STEPS TO REMAIN 2X4 HARDIE TRIM CONTINUOUS CLEAT 1/2" PLYWOOD SHEATHING W/ TYVEK DRAIN WRAP V.B. OR EQ. T.O. PARAPET WALL 15'-10" +/- METAL COPING COVER TO MATCH EXISTING ROOFING 2x6'S @ 16" O.C. - SEE STRUCTURAL TYPICAL SIDING 1'-0" FLYASH 1X4 ON TR. BLOCKING & FLYASH 1X6 TRIM HURRICANE CLIPS - SEE STRUCTURAL 2x6'S @ 16" O.C. WITH 1/2" PLYWD. SHEATHING & TYVEK DRAINWRAP OR EQ. SOFFIT BOARD WITH 1X2 BATTENS AT WALL AND PERPENDICULAR @ 8'-0" O.C. FLYASH 2X6 TRIM BOARD TYPICAL SIDING MTL. DRIP EDGE- COLOR TO MATCH ROOFING TO THE GREATEST EXTENT POSSIBLE. GRACE ICE & WATER SHIELD HT OR EQUAL OVER CDX 5/8" PLYWOOD STANDING SEAM ALUMINUM ROOFING - MATCH EXISTING 3 12 SEE STRUCTURAL FOR FOOTER AND REBAR NOTES PARGE BLOCK BELOW TO MATCH STUCCO SEE STRUCTURAL FOR ANCHOR NOTES RUN STUCCO UNDER TRIM 8" C.M.U. W/ CONC. FILLED CELLS- SEE STRUCTURAL FOR NOTES EXPOSED COPPER FLASHING CUT TR. 2X4 DRIP TRIM 1X12 FLYASH TRIM ON TR. 1X3 BLOCKING 1/2" SHEETROCK TYP. BASE TRIM OPEN CELL SPRAY FOAM INSULATION EQUAL TO R-19 14'-3 1/2" MSL - T.O. FLOOR 4" 3000 PSI CONC. SLAB W/ 6X6 10/10W.W.F.- FLOAT FINISH 10 MILL VAPOR BARRIER COMPACTED & TREATED SOIL COMPACTED & TREATED SOIL 1X FLYASH TRIM 1/4" HARDIE PANEL 7/8" CEMENT STUCCO ON METAL LATH, #15 FELT - MATCH STUCCO AS CLOSELY AS POSSIBLE TO EXISTING 1'-9" FLYASH 1X4 ON TR. BLOCKING & FLYASH 1X6 TRIM HURRICANE CLIPS - SEE STRUCTURAL 2x6'S @ 16" O.C. WITH 1/2" PLYWD. SHEATHING & TYVEK DRAINWRAP OR EQ. SOFFIT BOARD WITH 1X2 BATTENS AT WALL AND PERPENDICULAR @ 8'-0" O.C. FLYASH 2X6 TRIM BOARD TYPICAL SIDING - SEE EXT. ELEVATIONS MTL. DRIP EDGE- COLOR TO MATCH ROOFING TO THE GREATEST EXTENT POSSIBLE. GRACE ICE & WATER SHIELD HT OR EQUAL OVER CDX 5/8" PLYWOOD STANDING SEAM ALUMINUM ROOFING - MATCH EXISTING ALUMINUM RAIN GUTTERS TO MATCH EXISTING 7 12 TRUSS DESIGN BY OTHERS OPEN CELL SPRAY FOAM INSULATION EQUAL TO R-19 1'-0" TYP. TYPICAL RAMP @ 1:12 SLOPE ROOF W-PANS DRAIN TO GUTTER 6" FASCIA GUTTER CUSTOM LOW- COUNTRY METAL TUBE BRACKETS POST FLANGES BOLT TO CONCRETE FOUNDATION INTERNAL DRAINAGE IN HOLLOW POSTS TO GROUND POWDER-COATED CANOPY MEMBERS MATCH BEIGE STUCCO POWDER-COATED BRACKETS MATCH BEIGE STUCCO EPOXY #4 DOWELS INTO EXISTING FOUNDATION WALL & CMU AT 16" O.C. IN BOTH DIRECTIONS MATCH FOOTING DEPTH TO EXISTING FOUNDATION DEPTH ALIGN OLD AND NEW FLOOR LEVELS 1/2" GYP. BD. ON BOTH SIDES OF 2X6 AND 2X4 TO FILL FORMER OVERHEAD DOOR SPACE FLUSH WITH ADJACENT WALLS SEE STRUCTURAL FOR WALL & FOOTING REINFORCEMENT COMPACTED & TREATED SOIL EXISTING FOUNDATION COMPACTED & TREATED SOIL 10 MILL VAPOR BARRIER 4" 3000 PSI CONC. SLAB W/ 6X6 10/10W.W.F.- FLOAT FINISH SCALE: 1/4" = 1'-0" 7PARTIAL BUILDING SECTION A.3.0SCALE: 1/4" = 1'-0" 6SECTION THROUGH BACK PORCH A.3.0 SCALE: 1" = 1'-0" 3WALL PARAPET SECTION A.3.0SCALE: 1" = 1'-0" 2 BREEZEWAY-EAVE DETAIL A.3.0SCALE: 1" = 1'-0" 1TYPICAL WALL-FDN. DETAIL A.3.0 SCALE: 1" = 1'-0" 4HIP ROOF EAVE A.3.0 SCALE: 1/2" = 1'-0" 8TYPICAL METAL CANOPY SECTION A.3.0 SCALE: 1" = 1'-0" 5FOUNDATION CONNECTION A.3.0 Page 24 of 69 A R CH ITECT S A R CH ITECT S parkerdesigngrouparchitects 843 785 5171 POST OFFICE BOX 5010 HILTON HEAD ISLAND SC 29938 A facility upfit for: Hilton Head Island, South Carolina Memory MaƩers REVISIONS DATE DATE OF ISSUE: SHEET SGK SCALE DRAWN BY CHECKED BY JOB NO. These documents & designs are the property of Parker Design Group|Architects & are not to be used or reproduced there of or for designs, working drawings, or construction of buildings without the written authorization from the copyright owner PDG|Architects 2025 copyright C 2546 @ 15 Trellis Court FOR FINAL STATE REVIEW A.3.1 SECTIONS & DETAILS 7/27/2026 WTP DPH PROJECT #1016806 3'-0" 9'-0" SPRINKLER RISER ROOM SPRINKLER RISER DESIGN BY OTHERS 3 12 METAL CANOPY W/ WIRE TIEBACKS - MITCHELL METALS OR SIMILAR ART ROOM EXISTING BUILDING A.3.1 1 A.3.1 2 REMOVE EXISTING GUTTER & DOWNSPOUT AT ADDITION & RE-SLOPE REMAINING GUTTERS AS REQUIRED 3 12 FLYASH 1X6 ON TR. BLOCKING & FLYASH 1X4 TRIM HURRICANE CLIPS - SEE STRUCTURAL HARDIE SOFFIT BOARD WITH 1X2 BATTENS AT EDGE & WALL OPEN-CELL SPRAY FOAM INSULATION EQ. TO R-30 MTL. DRIP EDGE- COLOR TO MATCH ROOFING TO THE GREATEST EXTENT POSSIBLE. GRACE ICE & WATER SHIELD HT OR EQUAL OVER CDX 5/8" PLYWOOD STANDING SEAM ALUMINUM ROOFING - MATCH EXISTING 2X4 FRAMING AT 16" O.C. W/OPEN-CELL SPRAY FOAM INSULATION EQ. TO R-19 SPRINKLER SYSTEM DESIGN BY OTHERS 1/2" PLYWOOD SHEATHING MTL. DRIP EDGE- COLOR TO MATCH ROOFING TO THE GREATEST EXTENT POSSIBLE. 7/8" CEMENT STUCCO ON METAL LATH, #15 FELT, & TYVEC STUCCO WRAP OR EQUAL - MATCH STUCCO AS CLOSELY AS POSSIBLE EXISTING BUILDING T.O. SLAB 12.5 MSL 14'-3 1/2" MSL - T.O. FLOOR 10 MILL VAPOR BARRIER, TYP. 4" 3000 PSI CONC. SLAB W/ 6X6 10/10W.W.F.- FLOAT FINISH COMPACTED & TREATED SOIL EPOXY #4 DOWELS INTO EXISTING FOUNDATION WALL EXISTING FOUNDATION MATCH FOOTING DEPTH TO EXISTING FOUNDATION DEPTH SEE STRUCTURAL FOR CONCRETE REINFORCEMENT 1/4" : 1'-0" SLOPE 2X4 FRAMING AT 16" O.C. W/OPEN-CELL SPRAY FOAM INSULATION EQ. TO R-19 1/2" PLYWOOD SHEATHING 7/8" CEMENT STUCCO ON METAL LATH, #15 FELT, & TYVEC STUCCO WRAP OR EQUAL - MATCH STUCCO AS CLOSELY AS POSSIBLE COMPACTED & TREATED SOIL SIMPSON ABU44Z STAINLESS STEEL CONNECTION TR. 4X4 POSTS SLOPE CONCRETE 1/4" PER 1'-0" COMPACTED & TREATED SOIL (2) CONT. #5 BARS W/ PERP. #5'S @ 32" O.C.- SEE STRUCTURAL 4" 3000 PSI CONCRETE SLAB W/ BROOM FINISH FOR HEAT PUMPS ELEV 12.4 MSL TR. 2X8 CAP SLOPE SLIGHTLY 1 X 6 TRIM TR. 2 x 4's TR. 1 x 4 FRAME; TOP & BOTTOM 1 X 4 TREATED WD. BLADES 1 X 6 TRIM TR. 6X6 CHAMFERED POSTS, BEYOND 2X8 FLY ASH TRIM BOARD FYPON BRACVKET TBD 1X6 FLY ASH TRIM BOARD 2X4 FLY ASH TRIM BOARD AZEK PVC OR FLY ASH TRIM BOARD - 12" ACTUAL 2X6 FLY ASH TRIM BOARD 1X4 FLY ASH TRIM BOARDS, TYP. 2X2 FLY ASH TRIM BOARD 1X4 FLY ASH TRIM BOARDS, TYP. 1X4 FLY ASH TRIM BOARDS, TYP. 1/4 HARDIE PANEL 1/4 HARDIE PANEL 1X4 FLY ASH TRIM BOARDS, TYP. 3/4" FLY ASH QUARTER ROUND 1X12 FLY ASH TRIM BOARDS, TYP. 7/8" CEMENT STUCCO ON METAL LATH, #15 FELT - MATCH STUCCO AS CLOSELY AS POSSIBLE TO EXISTING PARGED STUCCO 6'-8" 4" 3000 PSI CONCRETE SLAB W/ BROOM FINISH - SLOPE 1/4" PER FOOT TOWARD BACK - SEE STRUCTURAL (2) CONT. #5 BARS W/ PERP. #5 BARS - SEE STRUCTURAL COMPACTED & TREATED SOIL ALUM. LOUVERS W/ 1" GAP 7/8" CEMENT STUCCO ON METAL LATH - COLOR TO MATCH BUILDING PRECAST CONCRETE CAP WITH DRIP AND SLOPED TO DRAIN SEE STRUCTURAL FOR CMU & FOOTER NOTES AND DIMENSIONS 12"x12" CMU PIER BLOCKS, TYP. SIMPSON STRONG TIE GALVANIZED POST BASE TR. SLOPED TOP, TYPICAL A.3.1 5 7'-0" 9'-8" 4-YARD DUMPSTER BY OTHERS CONCRETE-FILLED BOLLARDS CONCRETE APRON & DUMPSTER PAD LOUVERED GATES ALUMINUM LOUVERS SEE 5/A.3.1 TR. 6x6 TYP. DRILL HOLES IN CONCRETE FOR 3/4" METAL CANE BOLT USE IN BOTH CLOSED AND OPEN POSITIONS, TYPICAL ALUMINUM LOUVERS SEE 5/A.3.1 ALUMINUM LOUVERS SEE 5/A.3.1 +/- 5'-10" TR. 6X6 POSTS, TYPICAL ALUM. GATE FRAME AS PER OTHERS 5 1/2" WIDE ALUM. LOUVERS COLOR T.B.D. STUCCO POSTS - SEE 5/A.3.1 TR. SLOPED TOP, TYPICAL SCALE: 1/2" = 1'-0" 3LEAN-TO SPRINKLER RM SECTION A.3.1 SCALE: 1" = 1'-0" 1SPRINKLER RM. ROOF SECTION A.3.1 SCALE: 1" = 1'-0" 2SPRINKLER RM FOUNDATION SECTION A.3.1SCALE: 1" = 1'-0" 4SAFETY FENCE SECTION A.3.1 SCALE: 1" = 1'-0" 6TYPICAL PILASTER A.3.1 SCALE: 1" = 1'-0" 5DUMPSTER ENCLOSURE SECTION A.3.1SCALE: 1/2" = 1'-0" 8ENLARGED DUMSPTER ENCLOSURE A.3.1 SCALE: 1/2" = 1'-0" 7GATES - TRASH ENCLOSURE A.3.1 Page 25 of 69 A R CH ITECT S A R CH ITECT S parkerdesigngrouparchitects 843 785 5171 POST OFFICE BOX 5010 HILTON HEAD ISLAND SC 29938 A facility upfit for: Hilton Head Island, South Carolina Memory MaƩers REVISIONS DATE DATE OF ISSUE: SHEET SGK SCALE DRAWN BY CHECKED BY JOB NO. These documents & designs are the property of Parker Design Group|Architects & are not to be used or reproduced there of or for designs, working drawings, or construction of buildings without the written authorization from the copyright owner PDG|Architects 2025 copyright C 2546 @ 15 Trellis Court FOR FINAL STATE REVIEW A.5.0 ENLARGED FLOOR PLANS & ELEVS 7/27/2026 WTP DPH PROJECT #1016806 2 A.5.0 3 A.5.0 4 A.5.0 1'-4" 4" 3'-0" R 2'-9 1/2" 7'-8" 1'-0" 2'-4" 1'-2" 2'-2" 6'-8" 2'-8" TOILET TISSUE DISPENSER FD GFCI C WP PAPER TOWEL DISPENSER PULL CORD SANITARY DISPENSER NAMEEKS TECLA CONSOLE PER INTERIORS DELTA SAYLOR FAUCET 6 A.5.0 7 A.5.0 8 A.5.0 R 2'-9 1/2" 1'-4" 8'-2" 4" 1'-0" 2'-0" 1'-0" 2'-4" 1'-2" 2'-2" 6'-8" PULL CORD FD GFCI C WP PAPER TOWEL DISPENSER TOILET TISSUE DISPENSER SANITARY DISPENSER NAMEEKS TECLA CONSOLE PER INTERIORS DELTA SAYLOR FAUCET 10 A.5.0 R 2'-9 1/2" 1'-2" 2'-4" 1'-0" 4" 3'-0" 1'-9" 3'-9 1/2" 3'-10" 7'-1" 14'-8 1/2" 1'-4" 6'-8" 3'-6" 3'-2" C SANITARY DISPENSER FD PAPER TOWEL DISPENSER TOILET TISSUE DISPENSER GFCI WP SHOWER UNIT WITH SEAT- FREEDOM SHOWERS APFQ3637BF3PR OR SIMILAR PULL CORD ALERTS RECEPTIONIST 3'-4" 1'-6" 3'-0" 1'-5" 2'-10" 1'-6" 4'-0" PROVIDE SOLID BLOCKING IN WALLS AT GRAB BARS STAINLESS STEEL GRAB BARS, TYP. BLOCK WALL AT SINK & BRACING POINTS EBERN JAVEION MIRROR PER INTERIORS NAMEEKS TECLA BATHROOM CONSOLE PER INTERIORS 24" GRAB BAR FREEDOM SHOWER ADA PREFAB SHOWER Model APFXST3838BF.625 FOLD UP SEAT L-SHAPED GRAB BAR 1'-10" 3'-0" 1'-5" 1'-6"3'-4" 7"2'-3" 1'-10" 4" MAX. TO REFLECTING SURFACE PROVIDE SOLID BLOCKING IN WALL FOR GRAB BARS, TYP. BLOCK WALL AT SINK & BRACING POINTS PULL CORDS ALERT RECEPTIONIST EBERN JAVEION MIRROR PER INTERIORS NAMEEKS TECLA BATHROOM CONSOLE PER INTERIORS 1'-5" 1'-6"3'-4" 1'-10" 2'-3" 7" 4" MAX. TO REFLECTING SURFACE PROVIDE SOLID BLOCKING IN WALL FOR GRAB BARS, TYP. BLOCK WALL AT SINK & BRACING POINTS PULL CORDS ALERT RECEPTIONIST EBERN JAVEION MIRROR PER INTERIORS NAMEEKS TECLA BATHROOM CONSOLE PER INTERIORS LAVATORY VITREOUS CHINA ARCHER K-2355 4'-0" 2'-10" ADA 4" TOWEL DISPENSER PROVIDE SHROUD FOR PLUMBING NAMEEKS TECLA BATHROOM CONSOLE PER INTERIORS PROVIDE WALL BLOCKING DELTA SAYLOR FAUCET 3'-4" 1'-6" 3'-0" 1'-10" 4'-0" PROVIDE SOLID BLOCKING IN WALLS AT GRAB BARS STAINLESS STEEL GRAB BARS, TYP. 3'-4" 1'-6" 3'-0" 1'-10" 4'-0" PROVIDE SOLID BLOCKING IN WALLS AT GRAB BARS STAINLESS STEEL GRAB BARS, TYP. LAVATORY VITREOUS CHINA ARCHER K-2355 4'-0" 2'-10" ADA 4" PROVIDE SHROUD FOR PLUMBING TOWEL DISPNSER NAMEEKS TECLA BATHROOM CONSOLE PER INTERIORS PROVIDE WALL BLOCKING DELTA SAYLOR FAUCET 1'-6" 2'-10" ADA 1'-6" 3'-8" 32" ADA BASE CAB. 2x4 S-4-S AS CROWN - PAINT ARTWORK OR MEMORY MATTERS IMAGERY CAMBRIA IRONSBRIDGE QUARTZ AS PER INTERIORS WOOD SHAKER CABINETS PAINTED PT2, TYPICAL 32" X 44" WALL CAB. 32" X 44" WALL CAB. 32" ADA BASE CAB. 32" ADA BASE CAB. DESCRIPTION TOILET ROOM ACCESSORY SCHEDULE 18" GRAB BAR DOUBLE TOILET ROLL 36" GRAB BAR 42" GRAB BAR BRADLEY WASHROOM ACCESSORIES ARE BASIS OF DESIGN U.N.O. MANUFACTURER BRADLEY MODEL NUMBER REMARKS BRADLEY BRADLEY BRADLEY SATIN CHROME ROLLED HAND TOWEL BRADLEY SATIN CHROME SATIN CHROME SATIN CHROME SATIN CHROME 8120-001180 8120-001360 8120-001420 522-00 2A01-11 ADA MIRROR TRASH CONTAINER PROVIDED BY OWNER EBERN DESIGN JAVEION SKU # ENDG2891 SANITARY DISPOSAL BRADLEY 4A10-11000 SATIN CHROME CLOTHES HOOK BRADLEY 932 INSIDE OF RR DOORS MOP SHELF/HOOKS BRADLEY 9983 ABOVE MOP SINK SCALE: 1/2" = 1'-0" 1ENLARGED RESTROOM 103 A.5.0 SCALE: 1/2" = 1'-0" 5ENLARGED RESTROOM 114 A.5.0 SCALE: 1/2" = 1'-0" 9SHOWER & RESTROOM A.5.0SCALE: 1/2" = 1'-0" 10SHOWER WALL ELEVATION A.5.0 SCALE: 1/2" = 1'-0" 2WET WALL ELEVATION RM 103 A.5.0 SCALE: 1/2" = 1'-0" 6WET WALL ELEVATION RM 114 A.5.0 SCALE: 1/2" = 1'-0" 4VANITY SECTION/ELEVATION A.5.0 SCALE: 1/2" = 1'-0" 3ROOM 103 SIDE ELEV. A.5.0 SCALE: 1/2" = 1'-0" 7ROOM 114 SIDE ELEVATION A.5.0SCALE: 1/2" = 1'-0" 8VANITY SECTION/ELEV 114 A.5.0 SCALE: 1/2" = 1'-0" 11ART ROOM CABINETS A.5.0 RESTROOM 102 SIMILAR Page 26 of 69 A R CH ITECT S A R CH ITECT S parkerdesigngrouparchitects 843 785 5171 POST OFFICE BOX 5010 HILTON HEAD ISLAND SC 29938 A facility upfit for: Hilton Head Island, South Carolina Memory MaƩers REVISIONS DATE DATE OF ISSUE: SHEET SGK SCALE DRAWN BY CHECKED BY JOB NO. These documents & designs are the property of Parker Design Group|Architects & are not to be used or reproduced there of or for designs, working drawings, or construction of buildings without the written authorization from the copyright owner PDG|Architects 2025 copyright C 2546 @ 15 Trellis Court FOR FINAL STATE REVIEW A.5.1 ENLARGED FLOOR PLANS & ELEVS 7/27/2026 WTP DPH PROJECT #1016806 2 A.5.1 7'-6 1/2" 4'-6" 7'-6 1/2" 19'-7" R 2'-9 1/2" R 2'-9 1/2" 10'-1" 3'-0" MIN.3'-0" MIN. 1'-6" MIN. LOCKED FIRST AID, ETC. ADJUSTABLE MEDICAL BED FBO ADJUSTABLE MEDICAL BED FBO POWER- LIFT RECLINER FBO PULL CORDS ALERT RECEPTIONIST LOCKED MEDS. CABINET SECRETARY DESK SELECTED BY INTERIORS CUBICLE CURTAINS BY OWNER ON CEILING TRACK 1'-6" MIN. 1'-2" MAX. 1'-6" MIN. 7 A.5.1 6 A.5.1 5 A.5.1 2'-2" 5'-0" 3'-0" 4'-11" 2'-0" 2'-10" 4'-2" 17'-1" 4'-0" 11'-6" 5'-0" 1'-9" 3'-5 1/2" 3'-2" PASS- THRU SERVING COUNTER PROOFER HEATED CABINET TO STAGE CATERED FOOD PANTRY ICETRO ICE MACHINE W/ DEDICATED WATER LINE, BACKFLOW PREVENTER, AND PROTECTED ICE SCOOP COVERED PORCH DISHWASHER/SANITIZER BY JACKSON DISHSTAR HAND SINK CATERED MEALS ARRIVE THROUGH THIS DOOR ATOSA ONE-DOOR REFRIGERATOR 3-COMPARTMENT STAINLESS STEEL SINK STAINLESS STEEL WORK ISLAND FOR PLATING FOOD FOUR-SEASONS ROOM WITH DINING TABLES DOWN BASE CABINETS WITH SHELVES OR CABINETS ABOVE, TYPICAL FIRE EXTINGUISHER CABINET ATOSA ONE-DOOR FREEZER 3'-0"-WIDE ELIASON DSP-3 STAINLESS STEEL 16 GA. DOORS PULL CORDS ALERT RECEPTIONIST ADJUSTABLE MEDICAL BED FBO PULL CORDS ALERT RECEPTIONIST ADJUSTABLE MEDICAL BED FBO POWER-LIFT RECLINER FBO PULL CORDS ALERT RECEPTIONIST CUBICLE CURTAINS BY OWNER ON CEILING TRACK 2'-10" 7'-0" 22'-3" 2'-6" 2'-2" 4" 7'-0" 1/2" 2'-0" 11" 4'-9"2'-7" 30" X 42" WALL CAB. 30" ADA BASE CAB. HAND SINK W/ 30" W KNEE SPACE, MIN. 3-COMPARTMENT SINK T.B.D. DISHWASH/ SANITZER MACHINE OPEN SHELVES OR UPPER CABINETS, T.B.D. LOCKABLE CHEMICALS CABINET ICE SCOOP ICE MACHINE WITH DEDICATED COLD WATER LINE WITH BACKFLOW PREVENTER 2'-10" 1'-8" 3'-6" 2" FILLER 4" 21" X 42" WALL CAB. 30" X 42" WALL CAB. 30" ADA BASE CAB. 30" ADA BASE CAB. 30" ADA BASE CAB. 24" ADA BASE CAB. PASS-THROUGH COUNTER TO 4-SEASONS ROOM IS CAMBRIA IRONSBRIDGE QUARTZ WITH 4"H BACKSPLASH PROOFER HEATED CABINET EXTERIOR DOOR WATER HEATER CLOSET WOOD SHAKER CABINETS PAINTED PT2, TYPICAL 4'-4" 3'-8" ALTOSA 1-DOOR REFRIG. 36" X 96" PANTRY W/ ADJ. SHELVES PROOFER HEATED CABINET 24" X 96" PANTRY W/ ADJ. SHELVES 36" X 96" PANTRY W/ ADJ. SHELVES WOOD SHAKER CABINETS PAINTED PT2, TYPICAL 27"Wx31-7/10"Dx83"HA B DIMENSIONSMARK MANUFACTURER AND MODEL NUMBER CATERING KITCHEN EQUIPMENT LIST ALTOSA REACH-IN FREEZER, MBF8501GR C REMARKS 27"Wx31-7/10"Dx83"HALTOSA REACH-IN REFRIGERATOR, MBF8505GR 21"Wx30-3/4"Dx66 1/2"HWINHOLT MOBILE PROOFER CABINET, NHPL-1836-ECOC D1 84"Wx25 1/2"Dx44 1/4"HSAPPHIRE MFRING 3-COMPARTMENT SINK, SMS-3-1620D E 17"Wx15"Dx14"HF 24 1/4"Wx25"Dx33 5/16"HJACKSON DISHWASHER/SANITIZER, DISHSTAR HT G 26"Wx28"Dx39"HICETRO AMERICA (MIDDLEBY) ICEMAKER, IU-0220-AC H 20 1/2"Wx16"Dx12 1/8"HSHARP MEDIUM-DUTY 1000W MICROWAVE, R-21LCFS INCLUDES 2 DRAINBOARDS D2 TAP PRE-RINSE FAUCET, TPRF-812 FOR 3-COMPARTMENT SINK SAPPHIRE MFRING WALL-MOUNT HAND SINK, SMHS-01-D INCLUDES FAUCET SET F INCLUDES FAUCET SET REQUIRES ICEPRO 500 WATER FILTER 2'-10" A.D.A. FILLER FILLER 1'-7" 1'-6" 4" 36" ADA BASE CAB. - W/ ADJ. SHELVES 36" ADA BASE CAB. - W/ ADJ. SHELVES 36" ADA BASE CAB. - W/ ADJ. SHELVES 36" ADA BASE CAB. - W/ ADJ. SHELVES CAMBRIA IRONSBRIDGE COUNTER & BACKSPLASH, TYP. WOOD LOUVERED CABINETS PAINTED PT-2 ARTWORK OR MEMORY MATTERS IMAGERY AS SELECTED BY INTERIORS CABINET SECTION 1'-6" 2'-10" ADA 1'-6" 3'-8" 32" ADA BASE CAB. 2x4 S-4-S AS CROWN - PAINT ARTWORK OR MEMORY MATTERS IMAGERY CAMBRIA IRONSBRIDGE QUARTZ AS PER INTERIORS WOOD SHAKER CABINETS PAINTED PT2, TYPICAL 32" X 44" WALL CAB. 32" X 44" WALL CAB. 32" ADA BASE CAB. 32" ADA BASE CAB. 2'-10" ADA 1'-6" 3'-10 1/2" 8'-6" 2x4 S-4-S AS CROWN - PAINT 36"x42" BULLETIN BOARD OF DAILY ACTIVITIES, MENUS, ETC. CAMBRIA IRONSBRIDGE QUARTZ AS PER INTERIORS WOOD SHAKER CABINETS PAINTED PT2, TYPICAL 32" X 46 1/2" WALL CAB. 32" X 46 1/2" WALL CAB. 18" ADA BASE CAB. 18" ADA BASE CAB. DESK CHAIR BY OWNER SCALE: 1/2" = 1'-0" 1ENLARGED RESTING ROOM A.5.1 SCALE: 1/2" = 1'-0" 4ENLARGED CATERING KITCHEN A.5.1 SCALE: 1/2" = 1'-0" 2RESTING ROOM ELEVATION A.5.1 SCALE: 1/2" = 1'-0" 53-COMPARTMENT SINK WALL ELEVATION A.5.1 SCALE: 1/2" = 1'-0" 6PASS-THROUGH SERVING COUNTER ELEV A.5.1 SCALE: 1/2" = 1'-0" 7PANTRY WALL ELEVATION A.5.1 SCALE: 1/2" = 1'-0" 3CLASSROOM BUFFETT ELEVATION A.5.1 SCALE: 1/2" = 1'-0" 9MUSIC ROOM CASEWORK A.5.1 SCALE: 1/2" = 1'-0" 8INFO DESK CASEWORK A.5.1 Page 27 of 69 STRUCTURAL NOTES 1. BUILDING CODE: 2021 SOUTH CAROLINA BUILDING CODE (SCBC): 2. GRAVITY LOADS (ASCE 7-16): DISTRIBUTED ROOF LL = 20 PSF DL = 20 PSF 1ST FLOORLL = 50 PSF DL = 50 PSF COLLATERAL LOAD CL = 5 PSF 3. WIND LOADS (ASCE 7-16/ 2021 SCBC): BASIC DESIGN WIND SPEED, V = 145mph ALLOWABLE STRESS DESIGN WIND SPEED, VASD = 112.3mph RISK CATEGORY II WIND EXPOSURE D INTERNAL PRESSURE COEFFICIENT, GC^pi = ±0.18 4. SEISMIC LOADS (ASCE 7-16/ 2021 SCBC): RISK CATEGORY II SEISMIC IMPORTANCE FACTOR, IE = 1.00 MAPPED SPECTRAL RESPONSE ACCELERATION PARAMETERS: SS = 0.456g; S1 = 0.152g SITE CLASS D DESIGN SPECTRAL RESPONSE ACCELERATION PARAMETERS: SDS = 0.437g; SD1 = 0.233g SEISMIC DESIGN CATEGORY D BASIC SEISMIC FORCE-RESISTING SYSTEM: STEEL ORDINARY MOMENT FRAMES: V = CsW W = EFFECTIVE SEISMIC MASS SEISMIC RESPONSE COEFFICIENT, CS = 0.125 RESPONSE MODIFICATION FACTOR, R = 3.5 ANALYSIS PROCEDURE: EQUIVALENT LATERAL FORCE METHOD 5. SNOW LOAD (ASCE 7-16): GROUND SNOW LOAD Pg = 0 PSF 6. RAIN LOAD DATA (2021 SCBC): RAIN INTENSITY i = 4.5 in/hr ROOF: 7 TO 45 DEGREESWALLS ZONEAREA(SF)+P -PASD +PASD -P 11042.267.7 25.3 40.6 120 36.5 59.7 21.9 35.8 150 28.9 49.1 17.3 29.5 1100 23.2 41.0 13.9 24.6 2e1042.281.0 25.3 48.6 2e20 36.571.9 21.943.1 2e50 28.9 59.8 17.3 35.9 2e100 23.2 50.6 13.9 30.4 2r1042.2 77.125.3 46.3 2r20 36.5 71.0 21.9 42.6 2r50 28.9 63.0 17.3 37.8 2r100 23.2 57.0 13.9 54.7 3 10 42.291.1 25.3 54.7 3 2036.5 76.4 21.9 45.8 3 5028.957.0 17.3 34.2 3 10023.2 57.0 13.9 34.2 410 57.0 61.8 34.2 37.1 420 54.4 59.2 32.6 35.5 450 51.0 55.8 30.6 33.5 4100 48.4 53.3 29.0 32.0 5 10 57.0 76.3 34.2 45.8 5 20 54.471.132.642.7 5 50 51.0 64.4 30.6 38.6 5 10048.459.2 29.0 35.5 a aHIP ROOF a = 3.0 FT 5 4 4 a a 15 1 1 2e 1 3 3 3 3 2e 2r COMPONENTS & CLADDING WIND PRESSURES (PSF) STRUCTURAL NOTESSTRUCTURAL DESIGN CRITERIA GENERAL REQUIREMENTS 1. WHERE A SECTION OR DETAIL IS SHOWN FOR ONE CONDITION, IT SHALL APPLY TO ALL SIMILAR CONDITIONS. 2. COORDINATE ALL LIMITS AND DEPTHS OF DEPRESSIONS FOR FLOOR FINISHES WITH ARCHITECTURAL DRAWINGS AND SCHEDULES. LIMITS SHOWN ON STRUCTURAL DRAWINGS ARE SCHEMATIC. 3. THE DESIGN ADEQUACY AND SAFETY OF ERECTION BRACING, SHORING, TEMPORARY SUPPORTS, ETC. SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR. 4. DO NOT SCALE DRAWINGS. FOLLOW DIMENSIONS SHOWN ON PLANS. 5. CONTRACTOR SHALL COORDINATE AND VERIFY ALL DIMENSIONS AND ELEVATIONS SHOWN HEREIN WITH ARCHITECTURAL PLANS, SECTIONS, AND DETAILS PRIOR TO CONSTRUCTION OR MATERIAL PURCHASE AND SHALL NOTIFY ARCHITECT OR ENGINEER IN WRITING OF DISCREPANCIES. SEE ARCHITECTURAL DRAWINGS FOR ALL DIMENSIONS AND ELEVATIONS NOT SHOWN HEREIN. 6. DIMENSIONS INDICATED RELATIVE TO AN EXISTING STRUCTURE ARE APPROXIMATE AND SHALL BE FIELD VERIFIED BY THE CONTRACTOR PRIOR TO CONSTRUCTION OR MATERIALS PURCHASE. CONTRACTOR SHALL NOTIFY ARCHITECT OR ENGINEER IN WRITING OF DISCREPANCIES. 7. SPECIFIED ANCHOR SYSTEMS SHALL BE INSTALLED IN STRICT ACCORDANCE WITH MANUFACTURER'S WRITTEN INSTRUCTIONS. SPECIAL ATTENTION SHALL BE GIVEN TO THE DRILLING, CLEANING, AND PREPARATION OF HOLES. WHERE ADHESIVE ANCHORS ARE SHOWN, SPECIAL ATTENTION SHALL BE GIVEN TO THE REQUIRED MIXING, APPLICATION, AND CURING TIME OF ADHESIVE TYPE SPECIFIED. SUBGRADE PREPARATION 1. CONTRACTOR SHALL STRIP AND REMOVE ALL VEGETATION, TOPSOIL, ROOTS, AND ORGANIC SOILS FROM THE CONSTRUCTION AREA FOR A DISTANCE OF AT LEAST 10' BEYOND THE EXTENT OF BUILDING FOUNDATION LIMITS. THE DEPTH OF STRIPPING SHALL BE THAT REQUIRED TO REMOVE SIGNIFICANT ROOT ZONES, SMALL TREE STUMPS, AND OTHER UNACCEPTABLE MATERIALS, BUT IN NO CASE SHALL IT BE LESS THAN 12". 2. AFTER TOPSOILS, ETC. HAVE BEEN REMOVED FROM THE SITE WITHIN AND TO A POINT 10' OUTSIDE THE BUILDING CONSTRUCTION AREA, THE UPPER 24" OF EXPOSED SOILS SHALL BE COMPACTED TO A MINIMUM DENSITY OF 95% MODIFIED PROCTOR MAXIMUM DRY DENSITY (ASTM D1557) BY PROOFROLLING WITH A FULLY LOADED PNEUMATIC TIRED TANDEM AXLE DUMP TRUCK CAPABLE OF TRANSFERRING A LOAD OF 10 TO 20 TONS BY OVERLAPPING PASSES. A MINIMUM OF 8 COMPLETE PASSES SHALL BE MADE WITHIN THE BUILDING AREA. 3. PROOFROLLING SHALL BE PERFORMED UNDER THE OBSERVATION OF AN APPROVED TESTING LABORATORY SUPERVISED BY A GEOTECHNICAL ENGINEER. UNDERCUT, BACKFILL, AND COMPACT AREAS WHICH PUMP, DEFLECT, OR RUT EXCESSIVELY OR WHICH DO NOT STABILIZE AFTER SUCCESSIVE PASSES OF PROOFROLLING EQUIPMENT. 4. AFTER COMPLETION OF DENSIFICATION OF EXISTING SOILS, PLACE STRUCTURAL FILL FOR BUILDING AND PAVEMENT AREAS IN THIN (8" TO 10") LIFTS COMPACT TO A MINIMUM DENSITY OF 95% MODIFIED PROCTOR MAXIMUM DRY DENSITY (ASTM D1557). MATERIAL USED AS STRUCTURAL FILL SHALL BE NON-PLASTIC GRANULAR MATERIAL CONTAINING LESS THAN 15% FINES PASSING THROUGH THE NO. 200 SIEVE AND FREE OF ORGANICS, BOULDERS, OR OTHER DELETERIOUS MATERIALS. SLAB ON GRADE 1. APPLY AN APPROVED CURING COMPOUND CONFORMING TO ASTM C309 AFTER FINISHING THE SLAB. 2. ALL WELDED WIRE FABRIC SHALL BE IN ACCORDANCE WITH ASTM A185. LAP ADJOINING PIECES AT LEAST ONE FULL MESH OR 8" MINIMUM. UNLESS OTHERWISE APPROVED, ALL WELDED WIRE FABRIC SHALL BE BLOCKED INTO POSITION INDICATED WITH PRECAST CONCRETE BLOCKS HAVING A COMPRESSIVE STRENGTH EQUAL TO THAT OF THE SLAB. 3. THE USE OF POLYPROPYLENE FIBERS (IN LIEU OF WELDED WIRE FABRIC) IS PROHIBITED WITHOUT THE WRITTEN AUTHORIZATION OF THE ENGINEER. 4. THE MAXIMUM SPACING OF JOINTS SHALL BE 15' OR AS SHOWN ON PLANS. 5. ALL POROUS FILL MATERIAL SHALL BE A CLEAN GRANULAR MATERIAL WITH 100% PASSING 1 1 2" SIEVE AND NO MORE THAN 5% PASSING A NO. 4 SIEVE. POROUS FILL SHALL BE COMPACTED TO 95% MODIFIED PROCTOR. DRY DENSITY PER ASTM D1557. 6. SLAB JOINTS SHALL BE FILLED WITH APPROVED MATERIAL. THIS SHOULD TAKE PLACE AS LATE AS POSSIBLE, PREFERABLY 4 TO 6 WEEKS AFTER THE SLAB HAS BEEN CAST. PRIOR TO FILLING, REMOVE ALL DEBRIS FROM THE SLAB JOINTS, THEN FILL IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. 7. SEE THE ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONS OF DEPRESSED SLAB AREAS AND DRAINS. SLOPE SLAB TO DRAINS WHERE SHOWN. 8. THE FINISH TOLERANCE OF ALL SLABS SHALL BE IN ACCORDANCE WITH ACI 301, TYPE A. 9. WALKWAYS AND OTHER EXTERIOR SLABS ARE NOT INDICATED ON THE STRUCTURAL DRAWINGS. SEE THE SITE PLAN AND ARCHITECTURAL DRAWINGS FOR LOCATIONS, DIMENSIONS, ELEVATIONS, JOINTING DETAILS AND FINISH DETAILS. 10. CONTROL JOINT SEALANT SHALL BE SIKADUR 51 NS/SL OR APPROVED EQUAL. EXPANSION AND ISOLATION JOINT SEALANT SHALL BE SIKAFLEX 1a OR APPROVED EQUAL. REINFORCING STEEL 1. ALL REINFORCING STEEL SHALL BE ASTM A615, GRADE 60, UNLESS NOTED OTHERWISE. 2. ALL WELDED WIRE FABRIC SHALL BE ASTM A185, 70 KSI MINIMUM YIELD STRENGTH. 3. ADDITIONAL REINFORCING AND THAT QUANTITY OF REINFORCING OCCURRING AT OPENINGS SHALL BE PLACED EQUALLY EACH SIDE OF OPENINGS AS DETAILED. 4. HOOKS IN REINFORCING ARE IN ADDITION TO LENGTH SHOWN. 5. REINFORCING IS TO BE SUPPORTED IN FORMS AND SPACED WITH WIRE BAR SUPPORTS ACCORDING TO CRSI "PLACING REINFORCING BARS" UNLESS NOTED OTHERWISE. 6. MINIMUM REINFORCING STEEL CLEAR COVERS ARE AS FOLLOWS: A. CONCRETE CAST DIRECTLY AGAINST EARTH - 3" B. INTERIOR SLABS -1" C. INTERIOR BEAMS AND COLUMNS -1 1/2" D. EXTERIOR BEAMS AND COLUMNS -2" E. EXTERIOR SLABS -1 1/2" 7. UNLESS NOTED OTHERWISE, ALL BAR REINFORCING LAP SPLICES SHALL HAVE A MINIMUM LAP LENGTH OF 48 BAR DIAMETERS. PLYWOOD / GYPBOARD SHEATHING 1. ALL PLYWOOD CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE AMERICAN PLYWOOD ASSOCIATION (APA) SPECIFICATIONS. 2. ALL ROOF PANEL SHEATHING SHALL BE PER PLAN. SUITABLE EDGE SUPPORT SHALL BE PROVIDED BY THE USE OF PANEL CLIPS OR BLOCKING BETWEEN FRAMING. 3. ALL FLOOR SHEATHING SHALL BE TONGUE & GROOVE PER PLAN. FIELD-GLUE USING ADHESIVES MEETING APA SPECIFICATIONS AFG-01, APPLIED IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. 4. ALL WALL PANEL SHEATHING SHALL BE PER PLAN. 5. INSTALL ALL PLYWOOD SHEATHING AT FLOOR AND ROOF WITH THE LONG DIMENSIONS OF THE PANEL ACROSS SUPPORTS AND WITH PANEL CONTINUOUS OVER TWO OR MORE SPANS. STAGGER PANEL END JOINTS. ALLOW 1/8" SPACING AT PANEL ENDS AND EDGES UNLESS OTHERWISE RECOMMENDED BY THE SHEATHING MANUFACTURER. 6. ALL NAILS SHALL NOT BE OVERDRIVEN. 7. ALL EXISTING WALLS SHALL BE SHEATHED PER PLAN. 8. PROVIDE BLOCKING AT UNSUPPORTED PANEL EDGES AS FOLLOWS: ROOFS AND FLOORS - ONLY WHERE INDICATED ON PLAN WALLS - FULLY BLOCKED 9. WHERE EITHER 2" OR 212" FASTENER SPACINGS ARE USED FOR WOOD STRUCTURAL PANELS USED AT ROOF OR FLOOR, THE FRAMING MEMBER AT THE ADJOINING PANEL SHALL BE 3" NOMINAL WIDTH AND THE NAILS AT PANEL EDGES SHALL BE STAGGERED IN TWO LINES. 10. ALL PLYWOOD AND SHEATHING SHALL BE APA RATED, BEAR THE STAMP OF AN APPROVED TESTING AGENCY, AND SHALL BE FABRICATED WITH EXTERIOR GLUE. NAILS AT ABUTTING PLYWOOD EDGES MUST PENETRATE THE SAME PIECE OF FRAMING OR BLOCKING. 11. PERIMETER OF ANY OPENINGS SHALL BE FASTENED AS BOUNDARY NAILING. 12. OPENINGS WITH A DIMENSION PERPENDICULAR TO THE JOISTS GREATER THAN 4'-0" SHALL BE BLOCKED BEYOND THE HEADERS, AND METAL TIES NOT LESS THAN 16 GAGE BY 11 2" WIDE WITH (8)-16d COMMON NAILS ON EACH SIDE OF THE HEADER-JOIST INTERSECTION SHALL BE PROVIDED. 13. AT SHEAR WALLS OR DRAG STRUTS, THE PLYWOOD DIAPHRAGM MUST BE NAILED TO TOP PLATES, MEMBERS, BLOCKING, ETC. AS FOLLOWS: EXTERIOR WALLS/ DIAPHRAGM EDGES: 1x BOUNDARY NAILING INTERIOR WALL LINES:2x BOUNDARY NAILING FOUNDATIONS 1. ALL FOUNDATION FILL SUBGRADE SOILS SHALL BE COMPACTED AS FOLLOWS: (REF. ASTM D1557) A. 95% MODIFIED PROCTOR FOR GREATER THAN 18" BELOW FINAL FILL. B. 98% MODIFIED PROCTOR FOR THE UPPER 18" BENEATH BUILDINGS AND PAVEMENTS. 2. SOILS TESTING LABORATORY SHALL CONDUCT COMPACTION TESTS IN ACCORDANCE WITH ASTM D6938. RATE OF COMPACTION SHALL BE AS FOLLOWS: A. ONE TEST FOR EACH SPREAD FOOTING; B. ONE TEST FOR EACH 50 LINEAR FEET OF CONTINUOUS FOOTING; C. ONE TEST FOR EACH 1000 S.F. OF SLAB. 3. FOUNDATIONS HAVE BEEN DESIGNED FOR 1,500 PSF MINIMUM ALLOWABLE SOIL BEARING PRESSURE. 4. REMOVE ALL WATER SOFTENED SOILS FROM FOOTING EXCAVATIONS PRIOR TO PLACING CONCRETE. FILL REMAINING VOIDS WITH ADDITIONAL CONCRETE. 5. SUPPORT ALL BOTTOM REINFORCEMENT IN FOUNDATION WITH STANDEES OR WHOLE CONCRETE BRICKS AT 48" O.C. MAX. REQUIRED CONCRETE COVER SHALL BE MAINTAINED AT ALL TIMES. 6. ALL FOOTING, PIER, AND OTHER FOUNDATION REINFORCING SHALL BE TIED IN PLACE PRIOR TO POURING CONCRETE. 7. WHERE FINISHED GRADES DIFFER ON OPPOSITE SIDES OF FOUNDATION WALLS, PROVIDE TEMPORARY BRACING. PREVENT LATERAL MOVEMENT UNTIL ALL ADJACENT FILLING, COMPACTION, FLOOR SLABS, AND FRAMING AT NEXT LEVEL OVER HAS BEEN COMPLETED. 8. UNLESS INDICATED ON FOUNDATION PLAN, VERTICAL STEPS IN FOOTINGS TO BE MAXIMUM 2'-0" VERTICAL SPACED NO LESS THAN 4'-0" O.C. HORIZONTALLY TO MAINTAIN MINIMUM 12" COVER BELOW FINISHED EARTH GRADE. 9. WHERE GRAVITY PLUMBING LINES OCCUR BELOW TOP OF WALL FOOTING, STEP FOOTING DOWN TO PROVIDE CLEARANCES INDICATED ON PLANS. COORDINATE WITH PLUMBING DRAWINGS FOR LOCATIONS, SIZES, AND INVERTS. 10. CONSTRUCTION JOINTS IN CONTINUOUS FOOTINGS TO BE FORMED VERTICALLY IN ACCORDANCE WITH FOUNDATION DETAILS IN PLANS. 11. PROVIDE 1/2" EXPANSION JOINT FILLER AROUND PERIMETER OF SLABS WHERE THEY ABUT VERTICAL SURFACES AND AT COLUMN ISOLATION JOINTS AS DETAILED. STRUCTURAL STEEL 1. APPLICABLE STRUCTURAL STEEL CODES: A. AISC SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS, 15TH EDITION B. AISC CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS AND BRIDGES 2. MATERIALS: "W" SHAPES -ASTM A992, GRADE 50 STEEL TUBING - ASTM A500, GRADE B, Fy = 46 KSI STEEL PIPE -ASTM A500, GRADE B, Fy = 42 KSI ALL OTHER -ASTM A36 ANCHOR BOLTS - ASTM A307 HIGH STRENGTH BOLTS - ASTM A325 ANCHOR RODS - ASTM F1554, GRADE 36 WELDING ELECTRODES - E70 SERIES 3. STRUCTURAL STEEL SHALL BE FABRICATED AND ERECTED ACCORDING TO THE LATEST EDITION OF AISC "SPECIFICATION, DESIGN, AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS" AND RELATED PUBLICATIONS SPECIFIED THEREIN. 4. ALL SHEAR AND TENSION TYPE BOLTED CONNECTIONS SHALL BE MADE WITH 3/4" DIAMETER ASTM A325N HIGH STRENGTH BOLTS. DESIGN TORQUE TO BE DEVELOPED USING LOAD INDICATOR WASHERS AS MANUFACTURED BY BETHLEHEM STEEL CORPORATION OR APPROVED EQUIVALENT. INSTALL AS PER MANUFACTURER'S PUBLISHED INSTRUCTIONS. ALL OTHER BOLTED CONNECTIONS MAY BE MADE WITH ASTM A307 BOLTS AND WASHERS. 5. STEEL FRAMING ERECTION INCLUDING ALL BOLTED AND WELDED CONNECTIONS, BRACING, AND ANCHORAGES SHALL BE COMPLETED AND PLUMB PRIOR TO PLACEMENT OF DECK. 6. NON-SHRINK, NON-METALLIC GROUT WITH A 28 DAY COMPRESSIVE STRENGTH OF 5000 PSI SHALL BE USED UNDER BASE PLATES. 7. ENGINEER SHALL BE CONTACTED FOR APPROVAL OF ANY FIELD MODIFICATIONS OF ANCHOR BOLTS OR RODS AND COLUMN BASE PLATES. 8. TEMPORARY BRACING OF STEEL STRUCTURAL ELEMENTS IS THE RESPONSIBILITY OF THE CONTRACTOR. STRUCTURAL STABILITY SHALL BE MAINTAINED AT ALL TIMES DURING THE ERECTION PROCESS. 9. FRAMING CONNECTIONS NOT DETAILED, OR CONNECTIONS THAT ARE MODIFIED FROM THOSE DETAILED SHALL BE DESIGNED BY SUPPLIER FOR THE END REACTION SHOWN ON THE PLAN. IF NO REACTION IS PROVIDED, CONNECTIONS SHALL BE DESIGNED FOR 1/2 THE BEAM MAXIMUM UNIFORM LOAD PER AISC MANUAL FOR STEEL CONSTRUCTION. 10. SHOP CONNECTIONS SHALL BE WELDED OR HIGH STRENGTH BOLTED. USE 3/16" FILLET WELD MINIMUM. 11. FIELD CONNECTIONS SHALL BE WELDED OR HIGH STRENGTH BOLTED AS DETAILED. NO FIELD WELDING OF HOT-DIPPED GALVANIZED MEMBERS IS ALLOWED. USE 3/16" FILLET WELD MINIMUM. 12. CONTRACTOR SHALL SUBMIT THE FOLLOWING FOR REVIEW: A. SHOP DRAWINGS OF STEEL DETAILS PRIOR TO FABRICATING STRUCTURAL STEEL. B. STRUCTURAL DESIGN CALCULATIONS AND MEMBERS SIZES FOR ALL STAIR MEMBERS AND CONNECTIONS NOT SHOWN HEREIN. C. STRUCTURAL STEEL CALCULATIONS AND MEMBER SIZES FOR ALL STAIR MEMBERS AND CONNECTIONS NOT SHOWN HEREIN. D. ERECTION DRAWINGS FOR ALL STAIR MEMBERS SIGNED AND SEALED BY A REGISTERED ENGINEER IN THE STATE APPLICABLE TO THE PROJECT. E. ERECTION DRAWINGS FOR ALL STAIR MEMBERS SIGNED AND SEALED BY A REGISTERED ENGINEER IN THE STATE APPLICABLE TO THE PROJECT. 13. ALL BRICK SHELF ANGLES SHALL BE HOT-DIPPED GALVANIZED. 14. ALL EXTERIOR ELEMENTS AND THOSE ELEMENTS NOTED TO BE GALVANIZED SHALL BE HOT-DIPPED GALVANIZED IN ACCORDANCE WITH ASTM A123 AFTER SANDBLAST CLEANING PER SSPC-SP10. USE ASTM A325 BOLTS HOT DIPPED GALVANIZED WITH GALVANIZED HARDENED WASHERS AND GALVANIZED HEAVY HEX NUTS FOR BOLTING OF GALVANIZED ITEMS. 15. STEEL COLUMNS, BASE PLATES, AND ALL STEEL BELOW GRADE SHALL HAVE A MINIMUM 3" CONCRETE COVER PROTECTION. 16. ALL SHOP AND FIELD WELDS SHALL BE PERFORMED BY A CERTIFIED WELDER IN ACCORDANCE WITH AWS D1.1. 17. A GAS CUTTING TORCH SHALL NOT BE USED FOR CUTTING HOLES OR CORRECTING MANUFACTURING ERRORS IN THE FIELD WITHOUT THE WRITTEN CONSENT OF THE ENGINEER OF RECORD FOR EACH OCCURRENCE. 18. STANDARD BRICK LINTELS: SPANS <2'-0": 1-BAR 2 1/2 x3/8 FOR EACH 4" WYTHE 2'-0" - 5'-0":1-L3 1/2 x 3 1/2 x 5/16 FOR EACH 4" WYTHE 5'-0" - 6'-0":1-L4 x 3 1/2 x 5/16 FOR EACH 4" WYTHE (LLV) 6'-0" - 8'-0":1-L5 x 3 1/2 x 5/16 FOR EACH 4" WYTHE (LLV) 8'-0" - 10'-0":1-L6 x 3 1/2 x 5/16 FOR EACH 4" WYTHE (LLV) A. MINIMUM 6" BEARING EACH END. INCREASE EACH BEARING LENGTH 1" FOR EACH FOOT OF SPAN OVER 6'-0" B. INCREASE WIDTH OF HORIZONTAL LEG WHERE REQUIRED TO COVER WALL CAVITY ABOVE. SEE ARCHITECTURAL DETAILS. CONCRETE MASONRY 1. APPLICABLE MASONRY CODES: A. TMS 402-2016 BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES. B. TMS 602-2016 SPECIFICATIONS FOR MASONRY STRUCTURES. 2. CONCRETE MASONRY UNITS SHALL BE LOAD BEARING TYPE CONFORMING TO ASTM C90 HAVING A MINIMUM COMPRESSIVE STRENGTH OF 2000psi. 3. ALL CELLS BELOW GRADE SHALL BE FILLED SOLID WITH GROUT OR CONCRETE. 4. MORTAR SHALL CONFORM TO ASTM C270 TYPE S. 5. REINFORCED WALLS, STIFFENERS, PIERS, ETC. SHALL BE FILLED IN MAXIMUM OF 4'-0" LIFTS. FILL SHALL BE MECHANICALLY MIXED (ASTM C476 COURSE) GROUT OR REGULAR WEIGHT CONCRETE (ASTM C94) WITH MAX 1/2" COARSE AGGREGATE HAVING NOT LESS THAN 3,000psi (MIN.) 28 DAY STRENGTH. SEE SPECIFICATIONS. 6. PLAIN END TWO CELL UNITS SHALL BE USED FOR BLOCKS THAT ARE TO HAVE CELLS REINFORCED OR FILLED. WEB SHELLS ADJACENT TO CELLS THAT ARE TO BE FILLED ARE TO BE BEDDED IN MORTAR. 7. FILL CELLS AS NOTED ON DRAWINGS WITH 3000psi GROUT CONFORMING TO ASTM C476 SPECIFICALLY DESIGNED FOR FILLING CELLS. 8. VERTICAL REINFORCING TO BE LAPPED 48 BAR DIAMETERS AT DOWELS AND SPLICES. 9. HORIZONTAL JOINT REINFORCING TO BE CONTINUOUS THROUGH REINFORCED CELLS. 10. PROVIDE 9 GA. GALVANIZED WIRE TRUSS OR LADDER TYPE HORIZONTAL JOINT REINFORCING CONFORMING TO ASTM A82 AT 16" O.C. OR AS INDICATED ON DRAWINGS. 11. SEE ARCHITECTURAL DRAWINGS FOR THE EXTENT AND EXACT LOCATION OF MASONRY WALLS. 12. WALL CONTROL JOINTS SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE FOLLOWING: A. WALL CONTROL JOINTS SHALL BE PROVIDED IN ALL CONCRETE MASONRY WALLS AT LOCATIONS INDICATED ON THE STRUCTURAL DRAWINGS BUT AT A SPACING NOT GREATER THAN 24'-0" O.C. B. HORIZONTAL JOINT REINFORCING SHALL BE INTERRUPTED AT EACH SIDE OF WALL CONTROL JOINTS C. WALL CONTROL JOINTS SHALL NOT BE PLACED OVER OPENINGS OR WITHIN JAMB WIDTH 13. BLOCK LINTELS SHALL BE SPECIALLY FORMED U-BLOCK LINTEL OR LOW WEB LINTEL UNITS WITH REINFORCEMENT AS SHOWN OR PRECAST UNITS DESIGNED FOR THE WEIGHT OF MASONRY ABOVE AND ALL OTHER APPLIED LOADS. 14. UNLESS NOTED OTHERWISE, PROVIDE CONTINUOUS 8" DEEP INTERMEDIATE BOND BEAMS AT MAXIMUM 8'-0" O.C. VERTICALLY. REINFORCE WITH (2) #5 CONTINUOUS BARS OR AS NOTED ON THE PLANS. INTERRUPT AT VERTICAL CONTROL JOINTS. PROVIDE BOND BEAM AT TOP OF ALL CMU WALLS. 15. PROVIDE (2) #5x24"x24" HORIZONTAL CORNER BARS AT CHANGES IN DIRECTION OF BOND BEAM. WHERE BOND BEAMS INTERRUPTED BY OPENINGS, HOOK 12" INTO REINFORCED JAMB. 16. UNLESS NOTED OTHERWISE, REINFORCED PIERS AT JAMBS OF OPENINGS SHALL BE DISCONTINUOUS ABOVE LINTEL BEARING EXCEPT AS FOLLOWS: OPENING 4'-0" TO 8'-0": CONTINUE JAMB REINFORCING 24" ABOVE OPENING OPENING OVER 8'-0": CONTINUE JAMB REINFORCING TO TOP OF WALL 17. ALL MASONRY WALLS SHOWN ON THESE STRUCTURAL DRAWINGS HAVE BEEN DESIGNED TO RESIST THE REQUIRED VERTICAL AND LATERAL FORCES IN THE FINAL CONFIGURATION ONLY. IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO ADEQUATELY BRACE THE WALLS FOR VERTICAL AND LATERAL LOADS THAT COULD POSSIBLY BE APPLIED PRIOR TO COMPLETION OF LATERAL SUPPORT BY CONNECTIONS AT FLOOR OR ROOF FRAMING LOCATIONS. 18. UNLESS SHOWN OTHERWISE IN WALL DETAILS, PLACE ONE VERTICAL #5 BAR IN FULLY GROUTED CELL @ 48" O.C. MINIMUM ALONG THE LENGTH OF WALLS. VERTICAL BARS TO EXTEND FROM FOOTING DOWEL BAR SPLICE TO TOP OF WALL AND SHALL PENETRATE INTO THE BOTTOM OF BOND BEAMS AT TOP OF WALL OR PARAPET 4" MINIMUM. 19. UNLESS SHOWN OTHERWISE, ONE VERTICAL #5 BAR IN A FULLY GROUTED CELL SHALL BE PLACED AT WALL CORNERS, AT THE ENDS OF WALLS, ON EACH SIDE OF DOORS AND WINDOW JAMBS, AND ON EACH SIDE OF MASONRY CONTROL JOINTS. VERTICAL BARS TO EXTEND FROM FOOTING DOWEL BAR SPLICE TO THE TOP OF WALL AND SHALL PENETRATE INTO THE BOTTOM OF BOND BEAMS AT TOP OF WALL OR PARAPET 4" MINIMUM. 20. STANDARD BRICK LINTELS: SPANS < 2'-0": 1-BAR 2 1/2 x3/8 FOR EACH 4" WYTHE 2'-0" - 5'-0":1-L3 1/2 x 3 1/2 x 5/16 FOR EACH 4" WYTHE 5'-0" - 6'-0":1-L4 x 3 1/2 x 5/16 FOR EACH 4" WYTHE (LLV) 6'-0" - 8'-0":1-L5 x 3 1/2 x 5/16 FOR EACH 4" WYTHE (LLV) 8'-0" - 10'-0":1-L6 x 3 1/2 x 5/16 FOR EACH 4" WYTHE (LLV) A. MINIMUM 6" BEARING EACH END. INCREASE EACH BEARING LENGTH 1" FOR EACH FOOT OF SPAN OVER 6'-0" B. INCREASE WIDTH OF HORIZONTAL LEG WHERE REQUIRED TO COVER WALL CAVITY ABOVE. SEE ARCHITECTURAL DETAILS. SHEET TITLE PROJECT No. DATE REV. No.DATENARRATIVE 0ISSUED FOR PERMIT MEMORY MATTERS RENOVATION AND ADDITION 15 TRELLIS COURT HILTON HEAD ISLAND, SOUTH CAROLINA 26-562 06-05-2026 SHEET No. STRUCTURAL DESIGN CONSULTANTS S100 No. 7089 SOUTH CAROLINA SHEARLOCK ENGINEERING, LLC CE NOITA RI TFICATE ZIRO OF HT AU 06-05-2026 1 UPDATED PER EXISTING CONDITIONS 07-21-2026 ENGINEERED WOOD TRUSSES 1. WOOD TRUSSES SHALL BE DESIGNED BY THE MANUFACTURER IN ACCORDANCE WITH THE APPLICABLE PROVISIONS OF THE LATEST EDITION OF THE NATIONAL DESIGN SPECIFICATIONS OF THE NATIONAL FOREST PRODUCTS ASSOCIATION, THE DESIGN SPECIFICATIONS FOR LIGHT METAL PLATE CONNECTED WOOD TRUSSES OF THE TRUSS PLATE INSTITUTE AND INTERNATIONAL BUILDING CODE. 2. ALL TRUSSED RAFTERS SHALL BE DESIGNED, FABRICATED, AND ERECTED TO SUPPORT THE FOLLOWING MINIMUM LOADS: LIVE - TOP CHORD = 20 PSF DEAD - TOP CHORD = 15 PSF DEAD - BOTTOM CHORD = 15 PSF + MECHANICAL EQUIPMENT 3. WOOD MATERIALS SHALL BE SOUTHERN PINE, DOUGLAS FIR OR LARCH AND SHALL BE KILN DRIED AND USED AT 19% MAXIMUM MOISTURE CONTENT. PROVIDE GRADE NO. 2 OR AS REQUIRED TO SATISFY STRESS REQUIREMENTS. 4. PROVIDE AT EACH SUPPORT GALVANIZED METAL HURRICANE PLATE ANCHORAGES SUFFICIENT TO RESIST HORIZONTAL AND VERTICAL WIND COMPONENTS WITH A SAFETY FACTOR OF 3. MINIMUM UPLIFT LOAD AS DETERMINED BY TRUSS MANUFACTURER FROM REQUIREMENTS OF LOCAL BUILDING CODES. 5. THE CONTRACTOR SHALL PROVIDE ALL TEMPORARY AND PERMANENT BRACING AS REQUIRED FOR SAFE ERECTION AND PERFORMANCE OF THE TRUSSES. THE GUIDELINES SET FORTH BY THE TRUSS PLATE INSTITUTE PUBLICATION "HIB-91, COMMENTARY AND RECOMMENDATIONS FOR HANDLING, INSTALLING AND BRACING METAL PLATE CONNECTED WOOD TRUSSES" SHALL BE A MINIMUM REQUIREMENT. 6. SHOP DRAWINGS, COMPUTATIONS, ETC. TO BE SUBMITTED FOR REVIEW. SHOP DRAWINGS SHALL PROVIDE ERECTION LAYOUT FOR TRUSS RAFTERS, OUTRIGGERS, HEADERS, BRACING, ETC. SEE ARCHITECTURAL AND STRUCTURAL PLANS FOR SUPPORT LOCATIONS. 7. CALCULATIONS AND DRAWINGS SHALL BEAR THE SEAL OF A PROFESSIONAL ENGINEER LICENSED IN THE STATE IN WHICH THE PROJECT IS BEING CONSTRUCTED. 8. TRUSS WEB TO CHORD CONNECTION SHALL BE MADE WITH APPROVED GALVANIZED STEEL TRUSS CONNECTION PLATES MEETING ALL REQUIREMENTS OF THE TRUSS PLATE INSTITUTE. 9. TRUSS MEMBERS AND COMPONENTS SHALL NOT BE CUT, NOTCHED, DRILLED NOR OTHERWISE ALTERED IN ANY WAY WITHOUT WRITTEN APPROVAL OF THE ENGINEER. 10. ALL TRUSS RAFTERS SHALL MEET THE FOLLOWING MINIMUM STRESS GRADES TOP CHORDS.......................SYP #2 KD MG BOTTOM CHORDS................SYP #2 KD MG WEB MEMBERS....................SYP #2 KD OTHER................................SYP #2 KDNOTE: THIS STRUCTURAL DESIGN INCLUDES THE RENOVATION OF AN EXISTING BUSINESS AND ADDITION OF A FOUR SEASONS ROOM AND CONNECTING BREEZEWAY. NEW CONCRETE RAMPS AND STAIRS AT ENTRYWAYS AND COVERED CANOPIES ARE ALSO INCLUDED ADDITIONS. SHEARLOCK ENGINEERING, LLC (SLE) ASSUMES THE EXISTING FOUNDATION AND FRAMING IS SOUND AND HAS BEEN DESIGNED IN ACCORDANCE WITH APPLICABLE IBC AND LOCAL BUILDING CODES AT THE TIME OF CONSTRUCTION. DEMOLITION IS SOLELY THE RESPONSIBILITY OF THE CONTRACTOR. SLE IS NOT RESPONSIBLE FOR MEANS AND METHODS OF CONSTRUCTION OR FINISH / STRUCTURAL ISSUES THAT MAY ARISE DURING CONSTRUCTION. PER 2021 IBC 102.7.1, ALL ADDITIONS, ALTERATIONS, AND REPAIRS OF THIS STRUCTURE ARE DESIGNED IN COMPLIANCE WITH CURRENT CODE REQUIREMENTS. DIMENSIONAL LUMBER FRAMING 1. ALL STRUCTURAL LUMBER DESIGN SHALL CONFORM TO THE REQUIREMENTS OF THE NATIONAL DESIGNS SPECIFICATION FOR WOOD CONSTRUCTION (NDS-2018). 2. LOCATION, NUMBER, AND DIMENSIONS OF FRAMING MEMBERS SHOW GENERAL ARRANGEMENT ONLY. ACTUAL SPANS, SPACING, ETC. SHALL BE DETERMINED FROM ARCHITECTURAL DETAILS. 3. SEE ARCHITECTURAL PLANS AND DETAILS FOR EDGE SECTIONS, HEADER AND LINTEL LOCATIONS, AND ALL NON-STRUCTURAL FRAMING AND TRIM. 4. ALL WOOD FRAMING MATERIAL SHALL BE SURFACED DRY AND USED AT 19% MAXIMUM MOISTURE CONTENT. ALLOWABLE STRESS REQUIREMENTS OF ALL MATERIALS SHALL BE IN ACCORDANCE WITH THE "SCHEDULE OF REQUIRED STRESS VALUES". 5. ALL STUD AND WALL FRAMING SHALL BE NO. 2 GRADE SOUTHERN YELLOW PINE (SYP). "STUD" GRADE MATERIAL IS STRICTLY PROHIBITED FROM USE. 6. ALL JOIST, RAFTER & MISC. FRAMING SHALL BE NO. 2 GRADE, SOUTHERN YELLOW PINE. PROVIDE FULL-DEPTH BLOCKING AT ENDS. PROVIDE FULL-DEPTH (OR METAL) BRIDGING AT MIDSPAN AND AT A MAXIMUM SPACING OF 8'-0" O.C. IN BETWEEN. 7. ALL LUMBER EXPOSED TO EXTERIOR ENVIRONMENT OR IN CONTACT WITH MASONRY OR CONCRETE SHALL BE PRESSURE TREATED TO A MINIMUM RETENTION OF 0.25 lbs. OF ACQ PER CUBIC FOOT OF WOOD, AND EACH PIECE SHALL BEAR THE THIRD PARTY QUALITY MARK, "ABOVE GRADE USE". ALL LUMBER IN CONTACT WITH THE GROUND SHALL BE PRESSURE TREATED TO A MINIMUM RETENTION OF 0.40 lbs. OF ACQ PER CUBIC FOOT OF WOOD, AND EACH PIECE SHALL BEAR THE THIRD PARTY QUALITY MARK, "GROUND CONTACT USE". REFERENCE AWPA STANDARD U1 TO THE REQUIREMENTS OF USE CATEGORY 4 (UC4B) AND ASTM D1760 FOR PRESSURE TREATMENT OF TIMBER PRODUCTS. 8. WHERE POSSIBLE ALL CUTS AND HOLES SHOULD BE COMPLETED BEFORE TREATMENT. CUTS AND HOLES DUE TO ON-SITE FABRICATION SHALL BE BRUSHED WITH 2 COATS OF COPPER NAPHTHENATE SOLUTION CONTAINING A MINIMUM OF 2% METALLIC COPPER IN SOLUTION (PER AWPS STANDARD M4). 9. THE CONTRACTOR SHALL CAREFULLY SELECT LUMBER TO BE USED IN LOAD BEARING APPLICATIONS. THE LENGTH OF SPLIT ON THE WIDE FACE OF 2" NOMINAL LOAD BEARING FRAMING SHALL BE LIMITED TO LESS THAN ½ OF THE WIDE FACE DIMENSION. THE LENGTH OF SPLIT ON THE WIDE FACE OF 3" (NOMINAL) AND THICKER LUMBER SHALL BE LIMITED TO HALF OF THE NARROW FACE DIMENSIONS. 10. ALL WOOD JOISTS AND HEADERS WHICH FRAME INTO BEAMS SHALL BE SUPPORTED BY SIMPSON LUS HANGERS WITH THE SAME WIDTH AND DEPTH OF THE MEMBER, U.N.O. USE HANGERS WITH CONCEALED FLANGES WHERE THE CONNECTOR CANNOT BE HIDDEN BY WOOD TRIM OR THE SUPPORT MEMBER IS WIDER THAN THE STANDARD FLANGE. 11. PROVIDE NAILING PATTERN IN COMPLIANCE WITH IBC RECOMMENDED FASTENING SCHEDULE. 12. LOAD BEARING STUD WALLS SHALL BE CONTINUOUSLY BRIDGED AT MID-HEIGHT AND UNSUPPORTED PLYWOOD WALL SHEATHING JOINTS WITH SOLID WOOD BLOCKING, U.N.O. 13. NO CUTS, HOLES, OR COPES IN STRUCTURAL WOOD FRAMING SHALL BE PERMITTED WITHOUT PRIOR REVIEW AND APPROVAL BY THE STRUCTURAL ENGINEER AND ARCHITECT. 14. PROVIDE FULL-DEPTH BLOCKING AT ENDS OF RAFTERS AND JOISTS. PROVIDE FULL-DEPTH (OR METAL) BRIDGING AT MIDSPAN AND AT A MAXIMUM SPACING OF 8'-0" O.C. IN BETWEEN. 15. STRUCTURAL STEEL PLATE CONNECTORS SHALL CONFORM TO ASTM A36 SPECIFICATIONS AND BE ¼" THICK UNLESS OTHERWISE INDICATED. BOLTS CONNECTING WOOD MEMBERS SHALL BE PER ASTM A307 AND BE 3 4" DIAMETER UNLESS OTHERWISE INDICATED. PROVIDE WASHERS FOR ALL BOLT HEADS AND NUTS IN CONTACT WITH WOOD SURFACES. 16. BOLT HOLES SHALL BE CAREFULLY CENTERED AND DRILLED NOT MORE THAN 1/16" LARGER THAN THE BOLT DIAMETER. BOLTED CONNECTIONS SHALL BE SNUG TIGHT BUT NOT TO THE EXTENT OF CRUSHING WOOD UNDER WASHERS. 17. HOLES AND NOTCHES DRILLED OR CUT INTO WOOD FRAMING SHALL NOT EXCEED THE REQUIREMENTS OF IBC, SECTION 23. 18. ALL PLATES, ANCHORS, NAILS, BOLTS, NUTS, WASHERS, AND OTHER MISCELLANEOUS HARDWARE INSTALLED IN PRESSURE TREATED LUMBER, SHALL BE HOT DIP GALVANIZED. 19. ADEQUATE BRACING SHALL BE PROVIDED UNTIL PERMANENT BRACING AND/OR DIAPHRAGMS ARE INSTALLED. 20. OVERLAP ALL TOP PLATES AT CORNERS. 21. JOINTS IN THE DOUBLE TOP PLATES OF WALLS SHALL BE OFFSET A MINIMUM LAP LENGTH OF 4'-0" & NAILED WITH NOT LESS THAN (15)-16d FACE NAILS ON EACH SIDE OF THE JOINT. 22. ALL BEAMS SHALL HAVE LATERAL SUPPORT AT THE COMPRESSION EDGE AT A MAXIMUM OF 24" O.C. AND AT BEARING POINTS, WITH A MINIMUM BEARING LENGTH OF 3 1/2". 23. PROVIDE DOUBLE JOISTS OR SOLID BLOCKING AT 24" O.C. UNDER ALL PARTITIONS AND TO SUPPORT CONCENTRATED LOADS FROM FRAMING ABOVE UNLESS NOTED OTHERWISE. 24. PROVIDE DOUBLE HEADER BEAMS OF THE SAME SIZE AS JOISTS OR RAFTERS TO FRAME AROUND OPENINGS IN PLYWOOD DECK UNLESS OTHERWISE INDICATED. 25. PROVIDE DOUBLE LAYER PLYWOOD UNDER ALL CERAMIC OR STONE TILE FLOORS. 26. PROVIDE HEADERS, BRIDGING, CONNECTORS, BLOCKING, TRIMMERS, ETC. AS REQUIRED AND RECOMMENDED BY AITC TIMBER CONSTRUCTION STANDARDS AND 2021 SCBC U.N.O. 27. WOOD FRAMING MATERIALS: A. ALL DIMENSIONAL LUMBER SHALL BE #2 SYP KD OR BETTER AND PROVIDE NOT LESS THAN THE FOLLOWING ALLOWABLE STRESSES: Fb = 1,000 PSI Ft = 600 PSI E = 1,400,000 PSI Fc = 1,400 PSI Fcp = 565 PSI B. SHEATHING: WALLS..............................................APA RATED SHEATHING, EXPOSURE 1 OR EXTERIOR; ROOF................................................APA RATED SHEATHING, EXPOSURE1, 2, OR EXTERIOR; FLOOR..............................................APA RATED STURD-I-FLOOR; C. ALL BOLTS SHALL BE ASTM A307 WITH WASHERS, GALVANIZED; D. NAILS IN ACCORDANCE WITH MINIMUM NAILING REQUIREMENTS OF SCBC EXCEPT WHERE NOTED IN DETAILS OR SPECIFICATIONS. ALL NAILS TO BE GALVANIZED. CAST-IN-PLACE REINFORCED CONCRETE 1. THE FOLLOWING ACI STANDARDS (LATEST EDITION) APPLY: A. ACI 318 - CODE B. ACI 315 - DETAILING C. ACI 301 - SPECIFICATIONS D. ACI 304 - PLACING E. ACI 347 - FORMWORK F. ACI 211.1 - MIX PROPORTIONING G. ACI 305 - HOT WEATHER CONCRETING H. ACI 306 - COLD WEATHER CONCRETING 2. ALL CONCRETE SHALL BE NORMAL WEIGHT CONCRETE (145 PCF) WITH MIXES MEETING THE FOLLOWING CRITERIA: STRUCTURAL ELEMENT28 DAY COMPRESSIVE STRENGTH FOOTINGS, GRADE BEAMS & FOUNDATION WALLS3,000 PSI SLAB ON GRADE3,000 PSI ELEVATED SLABS & BEAMS4,000 PSI COLUMNS4,000 PSI 3.SLUMP SHALL NOT EXCEED 5". SLUMP TESTS SHALL BE PERFORMED ON EACH TRUCK LOAD AND CONFORM TO ASTM C143. No. 33500 REGISTEREDPROFESSIONAL ENGINEER SOUTH CAROLINA JAKE EAVENSON 10/19/2023 07/21/2026 Page 28 of 69 1 S200 DEMOLITION PLAN SCALE: 1/8" - 1'-0" DEMOLITION KEY NOTES: 1. G.C. TO VERIFY ALL INTERIOR WALLS TO BE DEMOLISHED PER ARCH. PLANS ARE NON-LOAD BEARING AND NOTIFY E.O.R. OF DISCREPANCIES IN FIELD. G.C. TO DEMO EXISTING WING WALL OF RAMP AS REQUIRED FOR NEW FOOTING AND CMU WALL DEMOLISH AND REMOVE EXISTING STAIRS AND LANDING (TYP. OF 2) DEMOLISH EXISTING INTERIOR NON-LOADING BEARING WALL (TYP.) - SEE ARCH. DEMOLISH EXISTING INTERIOR NON-LOADING BEARING WALL (TYP.) - SEE ARCH. REMOVE EXISTING WINDOW ASSEMBLY FOR NEW OPENING - EXISTING MASONRY LINTEL AND JAMBS TO REMAIN DEMOLISH AND REMOVE EXISTING ENTRY SLAB TO PREPARE FOR NEW FOOTINGS AND SLAB DEMOLITION PLAN SHEET TITLE PROJECT No. DATE REV. No.DATENARRATIVE 0ISSUED FOR PERMIT MEMORY MATTERS RENOVATION AND ADDITION 15 TRELLIS COURT HILTON HEAD ISLAND, SOUTH CAROLINA 26-562 06-05-2026 SHEET No. STRUCTURAL DESIGN CONSULTANTS S200 No. 7089 SOUTH CAROLINA SHEARLOCK ENGINEERING, LLC CE NOITA RI TFICATE ZIRO OF HT AU 06-05-2026 1 UPDATED PER EXISTING CONDITIONS 07-21-2026 1 No. 33500 REGISTERED PROFESSIONAL ENGINEER SOUTH CAROLINA JAKE EAVENSON 10/19/2023 07/21/2026 Page 29 of 69 #5 @ 24" O.C. F1 MARK W L T FOOTING SCHEDULE 'A' BARS'B' BARS 1'-0" CONT. 1'-8"(2)-#5 BOTT W L T 3" (TYP.) PLAN SECTION FOOTING DETAIL "A" BARS "B" BARS #5 @ 24" O.C. F21'-0" CONT. 2'-6"(3)-#5 BOTT F31'-6" 3'-0"(4)-#5 BOTT (4)-#5 TOP 3'-0"(4)-#5 BOTT (4)-#5 TOP F41'-6" 3'-6"(4)-#5 BOTT (4)-#5 TOP 3'-6"(4)-#5 BOTT (4)-#5 TOP F51'-6" 3'-6"(4)-#5 BOTT (4)-#5 TOP 5'-6"(6)-#5 BOTT (6)-#5 TOP FOUNDATION NOTES: 1. CONTRACTOR SHALL COORDINATE ALL FLOOR DRAIN SIZES AND LOCATIONS WITH ARCHITECTURAL PLANS. 2. AT FLOOR DRAINS, SLOPE FLOOR 12" FOR 2'-0"Ø AREA CENTERED ON DRAIN. (SEE PLUMBING DRAWINGS) TOP OF DRAIN COVER SHALL BE FLUSH WITH ADJACENT FLOOR FINISH MATERIAL. WHEN LOCATED IN CERAMIC TILE FLOOR, GROUT AREA BETWEEN CERAMIC TILE AND EDGE OF DRAIN. MAINTAIN SLAB THICKNESS AT ALL SLOPES AND DEPRESSIONS. 3. ALL THICKENED SLABS SHALL BE CENTERED BELOW PROPOSED WALL ABOVE. MASONRY NOTES: 1. ALL LOAD BEARING MASONRY WALLS SHALL BE 2000psi (MIN) 8x8x16" OR 12x8x16" UNITS. 2. ALL CELLS SHALL BE GROUTED SOLID W/ 3000psi CONCRETE. 3. VERTICAL REINFORCEMENT SHALL BE #5 BARS @ 24" O.C. IN 8" MASONRY WALLS. 4. VERTICAL REINFORCEMENT SHALL BE (2) #5 BARS @ 24" O.C. IN 12" MASONRY WALLS 5. HORIZONTAL REINFORCEMENT SHALL BE W2.8 LADDER STYLE JOINT REINFORCING @ 16" O.C. VERTICAL. 6. MASONRY BOND BEAMS SHALL BE INSTALLED AT TOP OF WALL IN ACCORDANCE WITH STRUCTURAL NOTES ON S100. 7. 12" SQ. MASONRY PIERS, SHALL BE GROUTED SOLID W/ 3000 PSI CONCRETE AND (4) #5 BARS VERTICAL AND #3 TIES @ 8" O.C. 1 S201 FOUNDATION PLAN SCALE: 1/8" - 1'-0" 5'-6"10'-10" 24'-0" 24'-0" 29'-6" 24'-0" 12" CMU WALL F2 F2 F2 29'-11" 14'-5" F1 F1 12'-4" 5'-6"F2 8" CMU WALL (TYP.) EXISTING TO REMAIN F3 F3 F3 F5 F4F4F4 F4F4F4 F4 F4 9'-3"9'-3"9'-3" 8" CMU WALL (TYP.) 4'-2" F1 12" CMU WALL 6'-10" F4 7'-3" 1'-10" 6'-6" 6'-6" 1'-314" 36'-4" 1 S300 4 S300 F1 3 S300 COLUMN FOUNDATION ATTACHMENT TO BE DETAILED BY CANOPY MANUFACTURER AND SUBMITTED TO E.O.R. FOR APPROVAL PRIOR TO FABRICATION (TYP.) 1'-5" CMU WALL AT EXISTING FOUNDATION SIMILAR TO 3/S300 EXISTING CONCRETE LANDING AND STAIRS TO REMAIN - G.C. TO VERIFY CONDITION AND GEOMETRY IN FIELD 5'-2" 5'-0" 12 S300 F5 NOTE: ALL DIMENSIONS ARE APPROXIMATE. G.C. TO VERIFY ALL DIMENSIONS IN FIELD. ANCHOR BOLT NOTES: 1. PROVIDE 5/8"Ø x 10" LONG ANCHOR BOLTS W/ 2"x2"x14" THICK WASHER SPACED AT 32" O.C. ALONG WALL SILL PLATE AT ALL EXTERIOR WALLS & AS INDICATED - U.N.O. PROVIDE (2) BOLTS (MIN.) PER PIECE & 12" MAX FROM EACH END OF PIECE. 2. PROVIDE 14"x3" TAPCONS @ 24" O.C. (MIN.) AT ALL NEW INTERIOR NON-LOAD BEARING WALLS. PROVIDE (2) TAPCONS (MIN.) PER PIECE & 12" MAX FROM EACH END OF PIECE. - CONTROL JOINT (C.J.) - TURNDOWN SLAB - THICKENED SLAB - NEW NON-LOAD BEARING WALL - FOOTING MARK - SEE FOOTING SCHEDULE - COLUMN MARK - SEE COLUMN SCHEDULE GENERAL LEGEND - CMU WALL - SEE MASONRY NOTES F1 C1 - LOAD BEARING WALL (2) 2x6 STUD PACK HSS5x5x12 C1 C2 C3 2 N/A COLUMN SCHEDULE COLUMN TYPEMARK # OF KING STUDS AT EACH END FOR COLUMNS INSTALLED IN WALL FRAMING, THE COLUMN TYPE INDICATES THE NUMBER AND TYPE OF "JACK STUDS" DIRECTLY SUPPORTING THE BEAM. ADDITIONAL KING STUDS (IF APPLICABLE) ARE NOTED IN THE LAST COLUMN. N/A W16x31 FOUNDATION PLAN SHEET TITLE PROJECT No. DATE REV. No.DATENARRATIVE 0ISSUED FOR PERMIT MEMORY MATTERS RENOVATION AND ADDITION 15 TRELLIS COURT HILTON HEAD ISLAND, SOUTH CAROLINA 26-562 06-05-2026 SHEET No. STRUCTURAL DESIGN CONSULTANTS S201 No. 7089 SOUTH CAROLINA SHEARLOCK ENGINEERING, LLC CE NOITA RI TFICATE ZIRO OF HT AU 06-05-2026 1 UPDATED PER EXISTING CONDITIONS 07-21-2026 No. 33500 REGISTERED PROFESSIONAL ENGINEER SOUTH CAROLINA JAKE EAVENSON 10/19/2023 07/21/2026 Page 30 of 69 #5 @ 24" O.C. F1 MARK W L T FOOTING SCHEDULE 'A' BARS'B' BARS 1'-0" CONT. 1'-8"(2)-#5 BOTT W L T 3" (TYP.) PLAN SECTION FOOTING DETAIL "A" BARS "B" BARS #5 @ 24" O.C. F21'-0" CONT. 2'-6"(3)-#5 BOTT F31'-6" 3'-0"(4)-#5 BOTT (4)-#5 TOP 3'-0"(4)-#5 BOTT (4)-#5 TOP F41'-6" 3'-6"(4)-#5 BOTT (4)-#5 TOP 3'-6"(4)-#5 BOTT (4)-#5 TOP F51'-6" 3'-6"(4)-#5 BOTT (4)-#5 TOP 5'-6"(6)-#5 BOTT (6)-#5 TOP FOUNDATION NOTES: 1. CONTRACTOR SHALL COORDINATE ALL FLOOR DRAIN SIZES AND LOCATIONS WITH ARCHITECTURAL PLANS. 2. AT FLOOR DRAINS, SLOPE FLOOR 12" FOR 2'-0"Ø AREA CENTERED ON DRAIN. (SEE PLUMBING DRAWINGS) TOP OF DRAIN COVER SHALL BE FLUSH WITH ADJACENT FLOOR FINISH MATERIAL. WHEN LOCATED IN CERAMIC TILE FLOOR, GROUT AREA BETWEEN CERAMIC TILE AND EDGE OF DRAIN. MAINTAIN SLAB THICKNESS AT ALL SLOPES AND DEPRESSIONS. 3. ALL THICKENED SLABS SHALL BE CENTERED BELOW PROPOSED WALL ABOVE. MASONRY NOTES: 1. ALL LOAD BEARING MASONRY WALLS SHALL BE 2000psi (MIN) 8x8x16" OR 12x8x16" UNITS. 2. ALL CELLS SHALL BE GROUTED SOLID W/ 3000psi CONCRETE. 3. VERTICAL REINFORCEMENT SHALL BE #5 BARS @ 24" O.C. IN 8" MASONRY WALLS. 4. VERTICAL REINFORCEMENT SHALL BE (2) #5 BARS @ 24" O.C. IN 12" MASONRY WALLS 5. HORIZONTAL REINFORCEMENT SHALL BE W2.8 LADDER STYLE JOINT REINFORCING @ 16" O.C. VERTICAL. 6. MASONRY BOND BEAMS SHALL BE INSTALLED AT TOP OF WALL IN ACCORDANCE WITH STRUCTURAL NOTES ON S100. 7. 12" SQ. MASONRY PIERS, SHALL BE GROUTED SOLID W/ 3000 PSI CONCRETE AND (4) #5 BARS VERTICAL AND #3 TIES @ 8" O.C. 17'-0" 35'-0" 6'-0"18'-0"6'-0" 7'-0" 6" 5'-0" 1'-6" 14'-4"5'-0" T.O.S. = VARIES - SEE ARCH. 4" CONCRETE SLAB ON GRADE W/ 6x6-W2.1xW2.1 WWF (TYP) F.F.E. = MATCH EXISTING 4" CONCRETE SLAB ON FILL W/ 6x6-W2.1xW2.1 WWF (TYP) C.J. C.J. 12'-0"12'-0" 15'-2"8'-1" 4'-312" T.O.S. NEAR GRADE - SEE ARCH. 4" CONCRETE SLAB ON GRADE W/ 6x6-W2.1xW2.1 WWF (TYP) 5'-0" 1'-0" 38'-1012" T.O.S. = VARIES - SEE ARCH. 4" CONCRETE SLAB ON GRADE W/ 6x6-W2.1xW2.1 WWF (TYP) G.C. TO SLOPE EXTERIOR SLAB PER ARCH. 2 S300 1 S202 SLAB PLAN SCALE: 1/8" - 1'-0" 7'-3" 5'-0" 12" CMU WALL 12" CMU WALL C3 C3 C2 C3 C3 C2 C2 29'-11" 5'-2" T.O.S. = VARIES - SEE ARCH. 6" CONCRETE SLAB ON FILL 8" CMU WALL (TYP.) EDGE OF SLAB (TYP.) EDGE OF SLAB (TYP.) EDGE OF SLAB (TYP.) 1 S300 C.J. EQUAL 4 S300 3 S300 6 S300 6 S300 EQUAL LEVELING SLAB BY G.C. AS REQUIRED TO MATCH F.F.E. SERVICE YARD BY OTHERS NOTE: ALL DIMENSIONS ARE APPROXIMATE. G.C. TO VERIFY ALL DIMENSIONS IN FIELD. 5'-0" 4'-2" EXISTING TO REMAIN 5 S300 TYP. 1'-0" FRAMING NOTES: 1.ROOF SHEATHING: 15/32" APA-RATED 32/16 MIN. WOOD STRUCTURAL PANELS MANUFACTURED W/ EXTERIOR-GRADE GLUE & FASTENED W/ 8d COMMON NAILS (0.131"Øx2.5" LONG) OR GALVANIZED 8d BOX NAILS (0.113"Øx2.5" LONG) AS FOLLOWS: NAILING PATTERN: SUPPORTED EDGES & DIAPHRAGM BOUNDARIES: 6" O.C. FIELD & INTERMEDIATE SUPPORTS. 6" O.C. 2.ALL EXTERIOR WALLS ARE FRAMED W/ 2x6 @ 16" O.C. - U.N.O. 3.ALL NEW NON-LOAD BEARING WALLS ARE FRAMED W/ 2x4 @ 16" O.C. - TOP OF WALLS TO BE FASTENED TO EXISTING STEEL JOISTS PER 13/S400 & 14/S400. BOTTOM OF WALLS FASTENED PER ANCHOR BOLT NOTES & 5/S300. 4.ALL EXTERIOR WALL SHEATHING AS FOLLOWS (U.N.O.): 15/32" APA-RATED SHEATHING, 32/16 MIN. WOOD STRUCTURAL PANELS MANUFACTURED AS EXPOSURE 1 & FASTENED W/ 8d COMMON NAILS (0.131"Øx2.5" LONG) OR GALVANIZED 8d BOX NAILS (0.113"Øx2.5" LONG) AS FOLLOWS: NAILING PATTERN: SUPPORTED EDGES & DIAPHRAGM BOUNDARIES: 3" O.C. FIELD & INTERMEDIATE SUPPORTS: 12" O.C. ANCHOR BOLT NOTES: 1. PROVIDE 5/8"Ø x 10" LONG ANCHOR BOLTS W/ 2"x2"x14" THICK WASHER SPACED AT 32" O.C. ALONG WALL SILL PLATE AT ALL EXTERIOR WALLS & AS INDICATED - U.N.O. PROVIDE (2) BOLTS (MIN.) PER PIECE & 12" MAX FROM EACH END OF PIECE. 2. PROVIDE 14"x3" TAPCONS @ 24" O.C. (MIN.) AT ALL NEW INTERIOR NON-LOAD BEARING WALLS. PROVIDE (2) TAPCONS (MIN.) PER PIECE & 12" MAX FROM EACH END OF PIECE. - CONTROL JOINT (C.J.) - TURNDOWN SLAB - THICKENED SLAB - NEW NON-LOAD BEARING WALL - FOOTING MARK - SEE FOOTING SCHEDULE - COLUMN MARK - SEE COLUMN SCHEDULE GENERAL LEGEND - CMU WALL - SEE MASONRY NOTES F1 C1 - LOAD BEARING WALL (2) 2x6 STUD PACK HSS5x5x12 C1 C2 C3 2 N/A COLUMN SCHEDULE COLUMN TYPEMARK # OF KING STUDS AT EACH END FOR COLUMNS INSTALLED IN WALL FRAMING, THE COLUMN TYPE INDICATES THE NUMBER AND TYPE OF "JACK STUDS" DIRECTLY SUPPORTING THE BEAM. ADDITIONAL KING STUDS (IF APPLICABLE) ARE NOTED IN THE LAST COLUMN. N/A W16x31 2 S202 SERVICE YARD SLAB PLAN SCALE: 1/8" - 1'-0" 10'-8" 8'-0" EDGE OF SLAB 12" CMU PIER (TYP.) - SEE MASONRY NOTES T.O.S. NEAR GRADE - SEE ARCH. 4" CONCRETE SLAB ON GRADE W/ 6x6-W2.1xW2.1 WWF (TYP) NOTE: G.C. TO DEFER TO OWNER/ARCH. FOR LOCATION AND ORIENTATION OF NEW SERVICE YARD. 7 S300 NOTE: ALUMINUM LOUVERS FOR SERVICE YARD PER ARCH. AND ATTACHED TO STRUCTURE BY G.C. SLAB PLANS SHEET TITLE PROJECT No. DATE REV. No.DATENARRATIVE 0ISSUED FOR PERMIT MEMORY MATTERS RENOVATION AND ADDITION 15 TRELLIS COURT HILTON HEAD ISLAND, SOUTH CAROLINA 26-562 06-05-2026 SHEET No. STRUCTURAL DESIGN CONSULTANTS S202 No. 7089 SOUTH CAROLINA SHEARLOCK ENGINEERING, LLC CE NOITA RI TFICATE ZIRO OF HT AU 06-05-2026 1 UPDATED PER EXISTING CONDITIONS 07-21-2026 No. 33500 REGISTERED PROFESSIONAL ENGINEER SOUTH CAROLINA JAKE EAVENSON 10/19/2023 07/21/2026 Page 31 of 69 FRAMING NOTES: 1.ROOF SHEATHING: 15/32" APA-RATED 32/16 MIN. WOOD STRUCTURAL PANELS MANUFACTURED W/ EXTERIOR-GRADE GLUE & FASTENED W/ 8d COMMON NAILS (0.131"Øx2.5" LONG) OR GALVANIZED 8d BOX NAILS (0.113"Øx2.5" LONG) AS FOLLOWS: NAILING PATTERN: SUPPORTED EDGES & DIAPHRAGM BOUNDARIES: 6" O.C. FIELD & INTERMEDIATE SUPPORTS. 6" O.C. 2.ALL EXTERIOR WALLS ARE FRAMED W/ 2x6 @ 16" O.C. - U.N.O. 3.ALL NEW NON-LOAD BEARING WALLS ARE FRAMED W/ 2x4 @ 16" O.C. - TOP OF WALLS TO BE FASTENED TO EXISTING STEEL JOISTS PER 13/S400 & 14/S400. BOTTOM OF WALLS FASTENED PER ANCHOR BOLT NOTES & 5/S300. 4.ALL EXTERIOR WALL SHEATHING AS FOLLOWS (U.N.O.): 15/32" APA-RATED SHEATHING, 32/16 MIN. WOOD STRUCTURAL PANELS MANUFACTURED AS EXPOSURE 1 & FASTENED W/ 8d COMMON NAILS (0.131"Øx2.5" LONG) OR GALVANIZED 8d BOX NAILS (0.113"Øx2.5" LONG) AS FOLLOWS: NAILING PATTERN: SUPPORTED EDGES & DIAPHRAGM BOUNDARIES: 3" O.C. FIELD & INTERMEDIATE SUPPORTS: 12" O.C. ANCHOR BOLT NOTES: 1. PROVIDE 5/8"Ø x 10" LONG ANCHOR BOLTS W/ 2"x2"x14" THICK WASHER SPACED AT 32" O.C. ALONG WALL SILL PLATE AT ALL EXTERIOR WALLS & AS INDICATED - U.N.O. PROVIDE (2) BOLTS (MIN.) PER PIECE & 12" MAX FROM EACH END OF PIECE. 2. PROVIDE 1 4"x3" TAPCONS @ 24" O.C. (MIN.) AT ALL NEW INTERIOR NON-LOAD BEARING WALLS. PROVIDE (2) TAPCONS (MIN.) PER PIECE & 12" MAX FROM EACH END OF PIECE. - CONTROL JOINT (C.J.) - TURNDOWN SLAB - THICKENED SLAB - NEW NON-LOAD BEARING WALL - FOOTING MARK - SEE FOOTING SCHEDULE - COLUMN MARK - SEE COLUMN SCHEDULE GENERAL LEGEND - CMU WALL - SEE MASONRY NOTES F1 C1 - LOAD BEARING WALL (2) 2x6 STUD PACK HSS5x5x12 C1 C2 C3 2 N/A COLUMN SCHEDULE COLUMN TYPEMARK # OF KING STUDS AT EACH END FOR COLUMNS INSTALLED IN WALL FRAMING, THE COLUMN TYPE INDICATES THE NUMBER AND TYPE OF "JACK STUDS" DIRECTLY SUPPORTING THE BEAM. ADDITIONAL KING STUDS (IF APPLICABLE) ARE NOTED IN THE LAST COLUMN. N/A W16x31 1 S203 CEILING FRAMING PLAN SCALE: 1/8" - 1'-0" CEILING FORMED BY RAFTERS ABOVE OPEN TO ABOVE CEILING FORMED BY ACOUSTICAL TILE CEILING - SEE ARCH. CEILING FORMED BY RAFTERS ABOVE PRE-ENGINEERED CANOPY ABOVE BY OTHERS (3) 1.75"x9.25" 2.0E LVL (DROPPED)(2) 2x10 (3) 1.75"x9.25" 2.0E LVL C3 EXTEND STUD WALL PAST ROOF FRAMING TO FORM PARAPET WALL ABOVE - SEE 3/S400 C3 FACEMOUNT BEAM TO CORNER OF EXISTING WALL W/ CONCEALED FLANGE MASONRY HANGER OR EQUAL C2 C3 C3 INFILL CMU WALL MATCHING DEPTH OF EXISTING MASONRY WALL C1 C1 EXISTING MASONRY LINTEL TO REMAIN (3) 1.75"x9.25" 2.0E LVL (DROPPED) C2 (3) 1.75"x9.25" 2.0E LVL (DROPPED) (3) 1.75"x9.25" 2.0E LVL (DROPPED) C2 (3) 1.75"x9.25" 2.0E LVL (DROPPED) (3) 1.75"x9.25" 2.0E LVL (DROPPED) 4 S400 EXISTING STRUCTURE TO REMAIN NEW INFILL NON-LOAD BEARING WALL (TYP.) COLUMN PER CANOPY MANUFACTURER (TYP.) 5 S400 C1 (3) 2x10 (DROPPED & CONT.) 10 S400 SEE 11/S400 FOR BEAM CONNECTION @ CORNER STEEL COLUMN WALL TO BE FRAMED (2) 2x6 @ 16" O.C. 14 S400 TYP. CONCEALED HANGER TO STEEL COLUMN TO BEAM - SIMILAR TO 11/S400 C1 2x8 @ 16" O.C. NOTE: BEAMS NOTED AS "LOW" SHALL BE LOCATED AT THE TOP OF WINDOW ROUGH OPENINGS W/ CLEARANCE AS REQUIRED FOR INSTALLATION. 2 S203 PARTIAL HIGH CEILING FRAMING PLAN SCALE: 1/8" - 1'-0" C2C3 C3 C2 C2C3 C3 W14x26W14x26 W14x26 W14x26 W14x26W14x26 CEILING FORMED BY BOTTOM CHORD OF TRUSSES ABOVE TYPICAL EXTERIOR WALL FRAMING ABOVE LOW BEAM ON 1/S203 1 S400 6 S400 CEILING FRAMING PLANS SHEET TITLE PROJECT No. DATE REV. No.DATENARRATIVE 0ISSUED FOR PERMIT MEMORY MATTERS RENOVATION AND ADDITION 15 TRELLIS COURT HILTON HEAD ISLAND, SOUTH CAROLINA 26-562 06-05-2026 SHEET No. STRUCTURAL DESIGN CONSULTANTS S203 No. 7089 SOUTH CAROLINA SHEARLOCK ENGINEERING, LLC CE NOITA RI TFICATE ZIRO OF HT AU 06-05-2026 1 UPDATED PER EXISTING CONDITIONS 07-21-2026 1 No. 33500 REGISTEREDPROFESSIONAL ENGINEER SOUTH CAROLINA JAKE EAVENSON 10/19/2023 07/21/2026 Page 32 of 69 FRAMING NOTES: 1.ROOF SHEATHING: 15/32" APA-RATED 32/16 MIN. WOOD STRUCTURAL PANELS MANUFACTURED W/ EXTERIOR-GRADE GLUE & FASTENED W/ 8d COMMON NAILS (0.131"Øx2.5" LONG) OR GALVANIZED 8d BOX NAILS (0.113"Øx2.5" LONG) AS FOLLOWS: NAILING PATTERN: SUPPORTED EDGES & DIAPHRAGM BOUNDARIES: 6" O.C. FIELD & INTERMEDIATE SUPPORTS. 6" O.C. 2.ALL EXTERIOR WALLS ARE FRAMED W/ 2x6 @ 16" O.C. - U.N.O. 3.ALL NEW NON-LOAD BEARING WALLS ARE FRAMED W/ 2x4 @ 16" O.C. - TOP OF WALLS TO BE FASTENED TO EXISTING STEEL JOISTS PER 13/S400 & 14/S400. BOTTOM OF WALLS FASTENED PER ANCHOR BOLT NOTES & 5/S300. 4.ALL EXTERIOR WALL SHEATHING AS FOLLOWS (U.N.O.): 15/32" APA-RATED SHEATHING, 32/16 MIN. WOOD STRUCTURAL PANELS MANUFACTURED AS EXPOSURE 1 & FASTENED W/ 8d COMMON NAILS (0.131"Øx2.5" LONG) OR GALVANIZED 8d BOX NAILS (0.113"Øx2.5" LONG) AS FOLLOWS: NAILING PATTERN: SUPPORTED EDGES & DIAPHRAGM BOUNDARIES: 3" O.C. FIELD & INTERMEDIATE SUPPORTS: 12" O.C. - CONTROL JOINT (C.J.) - TURNDOWN SLAB - THICKENED SLAB - NEW NON-LOAD BEARING WALL - FOOTING MARK - SEE FOOTING SCHEDULE - COLUMN MARK - SEE COLUMN SCHEDULE GENERAL LEGEND - CMU WALL - SEE MASONRY NOTES F1 C1 - LOAD BEARING WALL 1 S204 ROOF FRAMING PLAN SCALE: 1/8" - 1'-0" PRE-ENGINEERED TRUSSES @ 24" O.C. PRE-ENGINEERED TRUSSES @ 24" O.C. PRE-ENGINEERED TRUSSES @ 24" O.C. HIP TRUSS HIP TRUSS HIP TRUSS HIP TRUSS 6 S400 BEAM BELOW (TYP.) SHED ROOF RAFTERS TO BE 2x8 @ 16" O.C. 5 S400 SHED ROOF RAFTERS TO BE 2x8 @ 16" O.C. GIRDER TRUSS BY MANUFACTURER STUD WALL EXTENDS PAST ROOF FRAMING TO FORM PARAPET - SEE 3/S400 EXISTING STRUCTURE TO REMAIN EXISTING PARAPET WALL TO REMAIN (TYP.) EXISTING HIGH ROOF TO REMAIN (TYP.) PRE-ENGINEERED CANOPY BY OTHERS SHED ROOF RAFTERS TO BE 2x8 @ 16" O.C. (TYP.)4 S400 POST RAFTERS TO WALL BELOW 1 S400 ROOF FRAMING PLAN SHEET TITLE PROJECT No. DATE REV. No.DATENARRATIVE 0ISSUED FOR PERMIT MEMORY MATTERS RENOVATION AND ADDITION 15 TRELLIS COURT HILTON HEAD ISLAND, SOUTH CAROLINA 26-562 06-05-2026 SHEET No. STRUCTURAL DESIGN CONSULTANTS S204 No. 7089 SOUTH CAROLINA SHEARLOCK ENGINEERING, LLC CE NOITA RI TFICATE ZIRO OF HT AU 06-05-2026 1 UPDATED PER EXISTING CONDITIONS 07-21-2026 No. 33500 REGISTERED PROFESSIONAL ENGINEER SOUTH CAROLINA JAKE EAVENSON 10/19/2023 07/21/2026 Page 33 of 69 SHEARWALL LEGEND SW-1 - HOLD DOWN - SEE SCHEDULEHD-1 MF-1 - SHEARWALL - SEE SCHEDULE - MOMENT FRAME - SEE SCHEDULE FRAMING NOTES: 1.ROOF SHEATHING: 15/32" APA-RATED 32/16 MIN. WOOD STRUCTURAL PANELS MANUFACTURED W/ EXTERIOR-GRADE GLUE & FASTENED W/ 8d COMMON NAILS (0.131"Øx2.5" LONG) OR GALVANIZED 8d BOX NAILS (0.113"Øx2.5" LONG) AS FOLLOWS: NAILING PATTERN: SUPPORTED EDGES & DIAPHRAGM BOUNDARIES: 6" O.C. FIELD & INTERMEDIATE SUPPORTS. 6" O.C. 2.ALL EXTERIOR WALLS ARE FRAMED W/ 2x6 @ 16" O.C. - U.N.O. 3.ALL NEW NON-LOAD BEARING WALLS ARE FRAMED W/ 2x4 @ 16" O.C. - TOP OF WALLS TO BE FASTENED TO EXISTING STEEL JOISTS PER 13/S400 & 14/S400. BOTTOM OF WALLS FASTENED PER ANCHOR BOLT NOTES & 5/S300. 4.ALL EXTERIOR WALL SHEATHING AS FOLLOWS (U.N.O.): 15/32" APA-RATED SHEATHING, 32/16 MIN. WOOD STRUCTURAL PANELS MANUFACTURED AS EXPOSURE 1 & FASTENED W/ 8d COMMON NAILS (0.131"Øx2.5" LONG) OR GALVANIZED 8d BOX NAILS (0.113"Øx2.5" LONG) AS FOLLOWS: NAILING PATTERN: SUPPORTED EDGES & DIAPHRAGM BOUNDARIES: 3" O.C. FIELD & INTERMEDIATE SUPPORTS: 12" O.C. ANCHOR BOLT NOTES: 1. PROVIDE 5/8"Ø x 10" LONG ANCHOR BOLTS W/ 2"x2"x14" THICK WASHER SPACED AT 32" O.C. ALONG WALL SILL PLATE AT ALL EXTERIOR WALLS & AS INDICATED - U.N.O. PROVIDE (2) BOLTS (MIN.) PER PIECE & 12" MAX FROM EACH END OF PIECE. 2. PROVIDE 1 4"x3" TAPCONS @ 24" O.C. (MIN.) AT ALL NEW INTERIOR NON-LOAD BEARING WALLS. PROVIDE (2) TAPCONS (MIN.) PER PIECE & 12" MAX FROM EACH END OF PIECE. MOMENT FRAME SCHEDULE MARK COLUMN BEAMCONNECTION MF-1HSS5x5x12 & W16x31W14x26CONN 1 - SEE DETAIL 9/S400 HOLD DOWN SCHEDULE MARKTYPEALTERNATEINSTALLATION HD-1SIMPSON HTT5 (OR EQUAL) 58"Ø THREADED RODPER MANUF. WITH (2) 2x6 COMPRESSION MEMBER FRAMING HD-2STEEL COLUMN PER PLANN/AN/A SHEARWALL SCHEDULE SHEATHING MARKSTRUCTURAL PANELFASTENER SIZESPACING AT PANEL EDGES SPACING AT PANEL FIELD SW-1 15/32" APA-RATED SHEATHING, 32/16 MIN. WOOD STRUCTURAL PANELS MANUFACTURED AS EXPOSURE 1 8d COMMON NAILS (0.131"Øx2.5" LONG) OR GALVANIZED 8d BOX NAILS (0.113"Øx2.5" LONG) 3" O.C. 12" O.C. 1 S210 SHEAR WALL PLAN SCALE: 1/8" - 1'-0" EXISTING TO REMAIN C3 C3 C2 C3 C3 C2 C2 MF-1 MF-1 MF-1 SW-1 HD-1 HD-2 SHEAR WALL PLAN SHEET TITLE PROJECT No. DATE REV. No.DATENARRATIVE 0ISSUED FOR PERMIT MEMORY MATTERS RENOVATION AND ADDITION 15 TRELLIS COURT HILTON HEAD ISLAND, SOUTH CAROLINA 26-562 06-05-2026 SHEET No. STRUCTURAL DESIGN CONSULTANTS S210 No. 7089 SOUTH CAROLINA SHEARLOCK ENGINEERING, LLC CE NOITA RI TFICATE ZIRO OF HT AU 06-05-2026 1 UPDATED PER EXISTING CONDITIONS 07-21-2026 No. 33500 REGISTEREDPROFESSIONAL ENGINEER SOUTH CAROLINA JAKE EAVENSON 10/19/2023 07/21/2026 Page 34 of 69 1 S300 FOUNDATION @ CMU STEM WALL NOT TO SCALE 1'-0" (MIN.) 1'-4" (2) #5 BARS (CONT.) 3" CLR. 3" CLR. 58"Ø HEADED ANCHOR BOLTS @ 32" O.C. P.T. 2x SILL PLATE EXTERIOR SHEATHING - SEE FRAMING NOTES 2x STUD WALL - SEE FRAMING NOTES FINISHED GRADE WWF - SEE PLAN CONCRETE SLAB - SEE PLAN x x x x x x x x #5 BARS @ 32" O.C. #5 BAR (CONT.) EXISTING STRUCTURE TO REMAIN DOWEL #5 BARS @ 24" O.C. INTO EXISTING FOUNDATION 6" (MIN.) W/ SIMPSON STRONG-TIE SET-3G EPOXY PER MANUFACTURER'S SPECIFICATIONS 2 S300 FOUNDATION @ SPRINKLER ROOM NOT TO SCALE #5 DOWEL @ 24" O.C. 3" CLR. 4" SAND LAYER 10 MIL VAPOR BARRIER 24" 24" xxxxxxxx WWF - SEE PLAN 58"Ø HEADED ANCHOR BOLTS @ 32" O.C. 512" MIN. P.T. 2x SILL PLATE EXTERIOR SHEATHING - SEE FRAMING NOTES SEE FOOTING SCHEDULE FOR SIZE AND REINFORCING 8" CMU WALL - SEE MASONRY NOTES FINISHED GRADE 1'-0" (MIN.) 3" CLR. 3" CLR. 6" 8" CMU BOND BEAM W/ (2) #5 BARS CONTINUOUS 2x STUD WALL - SEE FRAMING NOTES CONCRETE SLAB - SEE PLAN 4 S300 FOUNDATION AT STEEL COLUMN NOT TO SCALE 4" SAND LAYER 10 MIL VAPOR BARRIER xxxxxxxx SEE FOOTING SCHEDULE FOR SIZE AND REINFORCING 12" CMU WALL - SEE MASONRY NOTES FINISHED GRADE 1'-0" (MIN.) 3" CLR. 3" CLR. 6" 12" CMU BOND BEAM W/ (3) #5 BARS CONTINUOUS STEEL COLUMN - SEE PLAN CONCRETE SLAB - SEE PLAN NOTE: PROVIDE #5 DOWEL @ 24" O.C. IN SLAB HOOKED INTO CMU WALL PER 1/S300. PROTECT COLUMN W/ MASTIC COATING 58" THICK BASE PLATE - SEE DETAIL W16x31 PLATE DETAIL 58"x10"x1'-5" BASE PLATE 1'-5" 10" (4) 58"Øx12" HEADED NELSON STUDS PLUG WELDED TO THE BOTTOM OF PLATE 3"11"3" 3"5" 2" (4) 58"Øx12" HEADED NELSON STUDS PLUG WELDED TO THE BOTTOM OF PLATE STEEL COLUMN - SEE PLAN TYP.3/16 HSS5x5 PLATE DETAIL 58"x11"x0'-11" BASE PLATE 11" 11" (4) 58"Øx12" HEADED NELSON STUDS PLUG WELDED TO THE BOTTOM OF PLATE STEEL COLUMN - SEE PLAN TYP.3/16 2" 6" 3" 3"6" 2" WWF - SEE PLAN 512" MIN. 1'-0" EXISTING FOUNDATION TO REMAIN FINISHED GRADE 3000psi CONCRETE RAMP RAILING - PER OWNER(SEE ARCH. PLAN FOR EXACT DIMENSION) VARIES (3'-0" MAX.) COMPACTED SUBGRADE - SEE STRUCTURAL NOTES SEE FOOTING SCHEDULE FOR SIZE AND REINFORCING 40" 24" 3 S300 SECTION @ REAR RAMP NOT TO SCALE 1'-0" (MIN.) #5 BAR (CONT.) AT TOP OF WALL (TYP.) #5 HOOKED BAR MATCHING CMU VERTICAL REINFORCEMENT SPACING #5 BAR MATCHING VERTICAL REINFORCEMENT SPACING, HOOKED INTO FOOTING 8" CMU WALL - SEE MASONRY NOTES EXISTING FOUNDATION WALL TO REMAIN EXISTING FOUNDATION WALL TO REMAIN 6 S300 SLAB ON GRADE RAMP NOT TO SCALE 8" xxxxx CONCRETE SLAB - SEE PLAN WWF - SEE PLAN 3" CLR. 3" CLR. #5 BAR (CONT.) (TYP.) 8" FINISHED GRADE x x x x x 10 MIL VAPOR BARRIER 4" SAND LAYER COMPACTED SUBGRADE - SEE STRUCTURAL NOTES8" 8" SEE PLAN 1'-0" NOTE: SEE FOOTING SCHEDULE ON FOUNDATION PLAN FOR SIZE AND SPACING OF CONTINUOUS REINFORCING. BAR SIZE LAP 24" #5 #6 36" 30" #4 2"x4 KEY JOINT APPLY BONDING AGENT TO FIRST POUR 3" CLR. LAP (TYP) THICKNESS VARIES (SEE PLAN) 10 S300 CONSTRUCTION JOINT AT CONTINUOUS FOOTING NOT TO SCALE x x x x x x x x x x x x x 18" SAWCUT JOINT - FILL JOINT FULL DEPTH W/ SEMI-RIGID EPOXY JOINT FILLER - WWF DISCONTINUOUS AT JOINT COMPACTED SUBGRADE - SEE STRUCTURAL NOTES 10 MIL VAPOR BARRIER 1" 112" APPLY CURING COMPOUND AFTER SLAB FINISHING IS COMPLETE 4" SAND LAYER CONCRETE SLAB - SEE PLAN WWF - SEE PLAN SAWCUT JOINT WITHIN 4 HOURS AFTER POURING CONCRETE SLAB. 9 S300 SLAB CONTROL JOINT DETAIL - 4" NOT TO SCALE BAR SCHEDULE BAR SIZE 24" X 30" 36" #6 #5 1 1 X VARIES X #4 X X CONTINUOUS FOOTING REINFORCING DOWEL BAR TO MATCH CONTINUOUS REINFORCEMENT DOWEL BAR TO MATCH CONTINUOUS REINFORCEMENT 1'-0" 2'-0" MAX. X MIN. LAP (TYP.) BAR SCHEDULE BAR SIZE #4 #5 #6 36" 30" 24" X NOTE: SEE FOOTING SCHEDULE ON FOUNDATION PLAN FOR SIZE AND SPACING OF CONTINUOUS REINFORCING. X X CORNER BARS TO MATCH CONTINUOUS REINFORCING (SEE SCHEDULE) WIDTH VARIES (SEE PLAN) WIDTH VARIES (SEE PLAN) 11 S300 CONTINUOUS REINFORCING AT CORNERS & INTERSECTIONS NOT TO SCALE 8 S300 STEP FOOTING NOT TO SCALE 5 S300 INTERIOR NON-LOAD BEARING WALL NOT TO SCALE EXISTING SLAB TO REMAIN P.T. 2x SILL PLATE INTERIOR NON-LOAD BEARING WALL - SEE FRAMING NOTES ATTACH SILL PLATE TO EXISTING SLAB W/ 14"Øx3" TAPCON SCREWS (OR EQUAL) @ 24" O.C. NOTE: WHERE RAMP TRANSITIONS TO FLAT SLAB ON GRADE, THICKEN SLAB TO 8" DEEP AND 16" WIDE W/ (2) #5 BARS (CONT.). 7 S300 CMU PIER @ SERVICE YARD NOT TO SCALE 1'-6" x x x xxxxxx 1'-0" (MIN.) 12" CMU PIER - SEE MASONRY NOTES 2 1 FINISHED GRADE 3" CLR. 3" CLR. CONCRETE SLAB - SEE PLAN WWF - SEE PLAN (2) #5 BARS (CONT.) COMPACTED SUBGRADE - SEE STRUCTURAL NOTES 10 MIL VAPOR BARRIER 4" SAND LAYER (4) #5 BARS HOOKED INTO FOUNDATION 1'-4" #5 BARS @ 32" O.C. NOTE: HEIGHT OF CMU PIER SHALL BE 7'-0" (MAX.) ABOVE SLAB ON GRADE. SEE FOOTING SCHEDULE FOR SIZE AND REINFORCING 3" CLR. 3" CLR. 12 S300 FOUNDATION @ PRE-ENGINEERED CANOPY COLUMN NOT TO SCALE 4" 6" (MIN.) FINISHED GRADE PRE-ENGINEERED CANOPY COLUMN AND ATTACHMENT BY FABRICATOR NOTE: COLUMN FOUNDATION ATTACHMENT TO BE DETAILED BY CANOPY MANUFACTURER AND SUBMITTED TO E.O.R. FOR APPROVAL PRIOR TO FABRICATION. FOUNDATION DETAILS SHEET TITLE PROJECT No. DATE REV. No.DATENARRATIVE 0ISSUED FOR PERMIT MEMORY MATTERS RENOVATION AND ADDITION 15 TRELLIS COURT HILTON HEAD ISLAND, SOUTH CAROLINA 26-562 06-05-2026 SHEET No. STRUCTURAL DESIGN CONSULTANTS S300 No. 7089 SOUTH CAROLINA SHEARLOCK ENGINEERING, LLC CE NOITA RI TFICATE ZIRO OF HT AU 06-05-2026 1 UPDATED PER EXISTING CONDITIONS 07-21-2026 6" No. 33500 REGISTERED PROFESSIONAL ENGINEER SOUTH CAROLINA JAKE EAVENSON 10/19/2023 07/21/2026 Page 35 of 69 RAFTER BEARING ELEV. SEE ARCH. PLAN ROOF SHEATHING - SEE FRAMING NOTES RAFTER - SEE PLAN 12 SEE ARCH. PLAN ROOF FINISH - SEE ARCH. PLANS PLATE LINE DOUBLE TOP PLATE 2x STUD WALL - SEE FRAMING NOTES EXTERIOR SHEATHING - SEE FRAMING NOTES 1 S400 EAVE DETAIL @ TRUSS NOT TO SCALE SIMPSON STRONG-TIE H2.5A HURRICANE CLIP OR EQUAL, AT EACH RAFTER CONNECTION 2 S400 TYPICAL ROOF EAVE FRAMING NOT TO SCALE SIMPSON STRONG-TIE LUS24 OR EQUAL 2x4 LEDGER BOARD FASTENED TO WALL W/ (2) 312" #12 WOOD SCREWS @ 16" O.C. SIDELAP W/ (4) 10d NAILS 3 S400 PARAPET WALL DETAIL NOT TO SCALE SIMPSON STRONG-TIE LRU28Z (OR EQUAL) AT EACH RAFTER ROOF SHEATHING - SEE FRAMING NOTES RAFTER - SEE PLAN 2x STUD WALL - SEE FRAMING NOTES P.T. 2x LEDGER BOARD FASTENED TO EACH STUD W/ (3) 312" #12 WOOD SCREWS (TYP.) FLASHING AND ROOF FINISH - SEE ARCH. PLAN EXTERIOR SHEATHING - SEE FRAMING NOTES ROOF SHEATHING - SEE FRAMING NOTES RAFTER - SEE PLAN ROOF FINISH - SEE ARCH. PLANS EAVE CONDITION - SEE ARCH. PLAN EXTERIOR SHEATHING - SEE FRAMING NOTES SEE 2/S400 FOR SOFFIT FRAMING & CONNECTION PLATE LINE 4 S400 SECTION AT SPRINKLER ROOM NOT TO SCALE DOUBLE TOP PLATE 2x STUD WALL - SEE FRAMING NOTES EXISTING STRUCTURE TO REMAIN GUTTER SYSTEM TO BE REMOVED PER ARCH. PLANS 5 S400 SECTION THROUGH BREEZEWAY NOT TO SCALE EXISTING ROOF STRUCTURE TO REMAIN EXISTING MASONRY WALL TO REMAIN 6 S400 ROOF TRUSS AT STEEL NOT TO SCALE (2) SIMPSON STRONG-TIE H3 HURRICANE CLIP OR EQUAL AT EACH TRUSS, ONE EACH SIDE OF TRUSS BLOCKING BETWEEN EACH TRUSS ROOF TRUSS PER MANUFACTURER EAVE CONDITION - SEE TRUSS MANUFACTURER EXTERIOR SHEATHING - SEE FRAMING NOTES ROOF SHEATHING - SEE FRAMING NOTES SIMPSON STRONG-TIE H2.5A HURRICANE CLIP OR EQUAL AT EACH TRUSS DOUBLE TOP PLATE BLOCKING BETWEEN EACH TRUSS ROOF TRUSS PER MANUFACTURER 2x STUD WALL - SEE FRAMING NOTES EAVE CONDITION - SEE TRUSS MANUFACTURER PLATE LINE EXTERIOR SHEATHING - SEE FRAMING NOTES ROOF SHEATHING - SEE FRAMING NOTES P.T. 2x PLATE FASTENED TO STEEL W/ (2) SIMPSON STRONG-TIE TFP1475 SCREWS @ 16" O.C. 2x STUD WALL - SEE FRAMING NOTES SINGLE TOP PLATE STEEL BEAM - SEE PLAN P.T. FULL-DEPTH BLOCKING FASTENED W/ 12"Ø THROUGH BOLTS @ 24" O.C., STAGGERED HIGH AND LOW EAVE CONDITION - SEE ARCH. PLAN 2x FRAMING @ 16" O.C. BLOCKING BETWEEN EACH RAFTER DOUBLE TOP PLATE RAFTER - SEE PLAN ROOF SHEATHING - SEE FRAMING NOTES BLOCKING BETWEEN RAFTERS IN LAST (2) BAYS PER 3/S401 SIMPSON STRONG-TIE LRU28Z (OR EQUAL) AT EACH RAFTER P.T. 2x LEDGER BOARD FASTENED TO EXISTING MASONRY WALL W/ (2) 14" TITEN TURBO MASONRY ANCHORS @ 16" O.C. SIMPSON STRONG-TIE H2.5A HURRICANE CLIP OR EQUAL, @ EACH RAFTER CONNECTION BLOCKING BETWEEN EACH RAFTER ROOF SHEATHING - SEE FRAMING NOTES JOIST - SEE PLAN ROOF FINISH - SEE ARCH. PLANS EAVE CONDITION - SEE ARCH. PLAN EXTERIOR SHEATHING - SEE FRAMING NOTES SEE 2/S400 FOR SOFFIT FRAMING & CONNECTION PLATE LINE DOUBLE TOP PLATE 2x STUD WALL - SEE FRAMING NOTES GUTTER SYSTEM TO BE REMOVED PER ARCH. PLANS SIMPSON STRONG-TIE LRU28Z (OR EQUAL) AT EACH RAFTER P.T. 2x LEDGER BOARD FASTENED TO EXISTING MASONRY WALL W/ (2) 14" TITEN TURBO MASONRY ANCHORS @ 16" O.C. SIMPSON STRONG-TIE H2.5A HURRICANE CLIP OR EQUAL, @ EACH RAFTER CONNECTION BLOCKING BETWEEN EACH RAFTER RAFTER - SEE PLAN 7 S400 RETROFIT CMU LINTEL NOT TO SCALE ELEVATION VIEW NOTE: SIMILAR CONNECTION AT BOTTOM OF POST. (2) SIMPSON STRONG-TIE ST6224 OR EQUAL - ONE EACH BEAM TO POST COLUMN - SEE PLAN BEAMS - SEE PLAN 8 S400 CONNECTION OF INTERIOR COLUMN TO BEAM NOT TO SCALE CLCOLUMN 38"x512"x1'-0" PLATE (TYP.)STEEL BEAM - SEE PLAN 3" 112" (4) 34"Ø A325N BOLTS IN 1316"Ø HOLES AT 234" GAGE, TOP AND BOTTOM (TYP.) 2" CLCOLUMN T.O.S. EL. COORD. W/ ARCH. 12"x512"x2'-5" PLATE STEEL BEAM - SEE PLAN 112" 38"x4"x6" PLATE W/ (2) 34"Ø A325N BOLT IN 1316"Ø HOLES (TYP.)3" (4) 34"Ø A325N BOLTS IN 1316"Ø HOLES AT 234" GAGE, TOP AND BOTTOM (TYP.) TYP. 1/4 1/4 12"x512"x612" PLATE (TYP.) 2" TYP.1/4 1/4 112" 9 S400 MOMENT FRAME CONNECTION NOT TO SCALE 3" 112" TYP.1/4 1/4 38"x512"x612" PLATE (TYP.) TYP. 1/4 1/4 TYP.1/4 CLCOLUMN 38"x4"x6" PLATE W/ (2) 34"Ø A325N BOLT IN 1316"Ø HOLES (TYP.) TYP.1/4 1/4 112" 3" 112" HSS COLUMN - SEE PLAN HSS COLUMN - SEE PLAN STEEL COLUMN - SEE PLAN 10 S400 LVL BEAM @ W COLUMN NOT TO SCALE STEEL COLUMN - SEE PLAN LVL BEAM - SEE PLAN FASTEN BEAM TO COLUMN W/ SIMPSON STRONG-TIE HUC610 W/ (4) 1" WELD SEGMENTS PER MANUFACTURER'S SPECIFICATIONS 11 S400 LVL BEAM @ HSS COLUMN NOT TO SCALE LVL BEAM - SEE PLAN FASTEN BEAM TO COLUMN W/ SIMPSON STRONG-TIE HUC610 W/ (8) #12 METAL SCREWS PER MANUFACTURER'S SPECIFICATIONS FASTEN JACK STUD TO STEEL W/ SIMPSON STRONG-TIE TFP1475 SCREWS @ 12" O.C. (VERTICAL) STEEL COLUMN - SEE PLAN 2x6 JACK STUD (TYP.) SIMPSON STRONG-TIE LUS26 @ EACH JOIST STEEL COLUMN - SEE PLAN FASTEN END STUD TO STEEL W/ SIMPSON STRONG-TIE TFP1475 SCREWS @ 12" O.C. (VERTICAL) BOUNDARY NAIL EXTERIOR SHEATHING TO END STUD EXTERIOR SHEATHING - SEE FRAMING NOTES PLAN VIEW 12 S400 HSS COLUMN HOLD DOWN DETAIL NOT TO SCALE EXISTING STEEL JOIST TO REMAIN L2x2x18 (LLV) FASTENED THROUGH BOTTOM CHORD OF EXISTING STEEL JOIST W/ 38"Ø BOLT 2x CONT. PLATE FASTENED TO BOTTOM OF ANGLE W/ (2) #12 SELF-TAPPING SCREWS INTERIOR NON-LOAD BEARING WALL - SEE FRAMING NOTES 13 S400 CONNECTION @ NON-LOAD BEARING WALL NOT TO SCALE 2x CONT. PLATE FASTENED TO BOTTOM OF ANGLE W/ (2) #12 SELF-TAPPING SCREWS INTERIOR NON-LOAD BEARING WALL - SEE FRAMING NOTES SINGLE TOP PLATE FASTENED TO CONTINUOUS PLATE ABOVE W/ SIMPSON STRONG-TIE SDPW14312 (OR EQUAL) PER MANUFACTURER'S SPECIFICATIONS SINGLE TOP PLATE FASTENED TO CONTINUOUS PLATE ABOVE W/ SIMPSON STRONG-TIE SDPW14312 (OR EQUAL) PER MANUFACTURER'S SPECIFICATIONS 14 S400 CONNECTION @ NON-LOAD BEARING WALL NOT TO SCALE EXISTING STEEL JOIST TO REMAIN 2x STUD WALL - SEE FRAMING NOTES 3 4" 3 4" NOTE: BEAMS NOTED AS "LOW" PER PLAN SHALL BE LOCATED AT THE TOP OF WINDOW ROUGH OPENINGS W/ CLEARANCE AS REQUIRED FOR INSTALLATION. NOTE: BEAMS NOTED AS "LOW" PER PLAN SHALL BE LOCATED AT THE TOP OF WINDOW ROUGH OPENINGS W/ CLEARANCE AS REQUIRED FOR INSTALLATION. DETAIL OMITTED STRUCTURAL DETAILS SHEET TITLE PROJECT No. DATE REV. No.DATENARRATIVE 0ISSUED FOR PERMIT MEMORY MATTERS RENOVATION AND ADDITION 15 TRELLIS COURT HILTON HEAD ISLAND, SOUTH CAROLINA 26-562 06-05-2026 SHEET No. STRUCTURAL DESIGN CONSULTANTS S400 No. 7089 SOUTH CAROLINA SHEARLOCK ENGINEERING, LLC CE NOITA RI TFICATE ZIRO OF HT AU 06-05-2026 1 UPDATED PER EXISTING CONDITIONS 07-21-2026 11 No. 33500 REGISTERED PROFESSIONAL ENGINEER SOUTH CAROLINA JAKE EAVENSON 10/19/2023 07/21/2026 Page 36 of 69 BOUNDARY NAILING ROOF FRAMING - SEE PLAN FIELD NAILING AT INTERMEDIATE SUPPORTS SUPPORTED PANEL EDGE NAILING DIRECTION OF FACE GRAIN SUPPORT ALL SHEATHING EDGES IN ACCORDANCE W/ DIMENSIONAL LUMBER FRAMING NOTES EXTERIOR ENDWALL BLOCKING FOR (2) JOIST BAYS BLOCKING BETWEEN JOISTS JOIST - SEE PLAN FLOOR OR CEILING JOISTS AA PLAN SECTION A-A 4 S401 CONNECTION OF ROOF SHEATHING NOT TO SCALE 3 S401 BLOCKING AT ENDWALL NOT TO SCALE SIMPSON STRONG-TIE H2.5A HURRICANE CLIP OR EQUAL, AT EACH RAFTER CONNECTION SIMPSON STRONG-TIE CS22 COILED STRAP W/ A MINIMUM OF (10) 10d OR (12) 8d NAILS IN BOTH CONNECTED MEMBERS COMPRESSION MEMBERS EACH SIDE OF ROD 2x BLOCKING @ 48" O.C. MAX AND @ EVERY FREE EDGE OF SHEATHING 2x STUDS @ 16" O.C. MAX. SIMPSON STRONG-TIE CNW OR EQUAL COUPLER NUT SIMPSON STRONG-TIE H2.5A HURRICANE CLIP OR EQUAL AT EACH RAFTER CONNECTION THREADED ROD - SEE HOLD DOWN SCHEDULE 6" (MIN.) ANCHOR BOLT EMBEDDED INTO FOUNDATION PER ASTM F1554 OR WITH SIMPSON SET EPOXY ANCHOR (6" MIN. EMBED.) GC TO COMPLY WITH MINIMUM DIMENSIONS SHOWN FOR WASHER AND NUT PLACEMENT 5" (MIN.) R.O. HEADER CRIPPLE STUD -SINGLE FOR R.O. < 4' -DOUBLE FOR R.O. < 8' (UNLESS NOTED OTHERWISE ON FRAMING PLANS) CRIPPLE STUDS TRUSS/ RAFTER BEARING T.O.S. RAFTER BEARING FULL HEIGHT STUDS EACH SIDE OF ROUGH OPENING - 12 OF STUDS INTERRUPTED BY ROUGH OPENING (2 MIN.) SILL ANCHOR BOLT - SEE ANCHOR BOLT NOTES 2 S401 UPLIFT STRAP CONNECTION NOT TO SCALE 1 S401 DETAIL AT THREADED ROD NOT TO SCALE HOLD DOWN AT ENDS OF SHEARWALLS - SEE PLAN FOR TYPE AND LOCATION 2'-0" (MAX.) BOUNDARY NAILING AT ALL EDGES HEADER - SEE SCHEDULE 2x BLOCKING W/ 12" C-D EXTERIOR GRADE PLYWOOD SHEATHING BETWEEN RAFTERS SIMPSON STRONG-TIE BEARING PLATE OR EQUAL DOUBLE 2x TOP PL. 2x BLOCKING W/ 12" C-D EXTERIOR PLYWOOD SHEATHING BETWEEN RAFTERS BOUNDARY NAILING AT ALL EDGES STUD SPACING SCHEDULE EXTERIOR LOAD BEARING WALLS 2x4(2)2x42x6 2x8 STUD SIZE UNBRACED LENGTH 10' 12' 14' 16' 18' 20' 8' 16"O.C. 16"O.C. 16"O.C. 16"O.C. 12"O.C. 16"O.C. 16"O.C. 16"O.C. 16"O.C. 16"O.C.16"O.C. 12"O.C. 16"O.C. 16"O.C. 12"O.C. 16"O.C. 16"O.C. 12"O.C.- - - - - - - - - - 6'-0" OR HEADER SCHEDULE R.O. WIDTH 4'-0" TO 6'-0" GREATER HEADER SIZE (3) 2x10 (MIN.) (2) 2x12 OR AS SHOWN LESS THAN 4'-0"(3) 2x8 (MIN.) # OF JACK STUDS EACH END # OF KING STUDS EACH END 22 23 12 STRUCTURAL DETAILS SHEET TITLE PROJECT No. DATE REV. No.DATENARRATIVE 0ISSUED FOR PERMIT MEMORY MATTERS RENOVATION AND ADDITION 15 TRELLIS COURT HILTON HEAD ISLAND, SOUTH CAROLINA 26-562 06-05-2026 SHEET No. STRUCTURAL DESIGN CONSULTANTS S401 No. 7089 SOUTH CAROLINA SHEARLOCK ENGINEERING, LLC CE NOITA RI TFICATE ZIRO OF HT AU 06-05-2026 1 UPDATED PER EXISTING CONDITIONS 07-21-2026 No. 33500 REGISTERED PROFESSIONAL ENGINEER SOUTH CAROLINA JAKE EAVENSON 10/19/2023 07/21/2026 Page 37 of 69 NAILING PROVIDED IN HORIZONTAL FRAMING MEMBER (SINGLE OR DOUBLE ROW) FOUNDATION - SEE PLAN PANEL ATTACHMENT TO BOTTOM PLATE - SEE DETAIL 5/S402 P.T. BOTTOM PLATE NAILING PROVIDED IN STUDS ON EACH SIDE OF HORIZONTAL JOINT BAND JOIST PANEL ATTACHMENT TO UPPER TOP PLATE - SEE DETAIL 5/S402 DOUBLE TOP PLATE BAND JOIST 6 S402 FOUNDATION - SEE PLAN PANEL ATTACHMENT TO BOTTOM PLATE - SEE DETAIL 5/S402 P.T. BOTTOM PLATE PANEL ATTACHMENT TO UPPER TOP PLATE - SEE DETAIL 5/S402 DOUBLE TOP PLATE 1 S402 HORIZONTAL FRAMING MEMBER NOT TO SCALE PANEL SPLICE OCCURRING OVER 4 S402 2 S402 PANEL SPLICE OCCURRING ACROSS STUDS NOT TO SCALE SHEAR WALL DESIGN NAIL SPACING NAIL SPACING AT INTERMEDIATE FRAMING, 12" O.C. UPLIFT NAIL SPACING PER PLAN 3 S402 PANEL ATTACHMENT NOT TO SCALE 8'-0" 4'-0" 3 4" 12" 514"6" SPACING (FOR SHEAR WALL DESIGN) INCREASE STUD NAILING FOR UPLIFT (EACH SIDE OF HORIZONTAL JOINT) INCREASE STUD NAILING FOR UPLIFT (EACH SIDE OF HORIZONTAL JOINT) 3 4" PANEL EDGE BLOCKING, SAME SPECIES AS TOP AND BOTTOM PLATES (2x FLAT-WISE SHOWN) 4 S402 DETAIL NOT TO SCALE 618" 12" 3 4" SPACING PANEL EDGE SPACING PANEL EDGE SPACING SINGLE ROW OF FASTENERS DOUBLE ROW OF FASTENERS SPACING 3 4" PANEL EDGE SHEATHING EDGE AT BOTTOM PLATE (SINGLE ROW AND DOUBLE ROW OF FASTENERS) 12" 12" SPACING SHEATHING EDGE AT TOP PLATE (SINGLE ROW AND DOUBLE ROW OF FASTENERS) SINGLE ROW OF FASTENERS DOUBLE ROW OF FASTENERS SPACINGPANEL EDGE SPACING PANEL EDGE 3 4" SINGLE ROW OF FASTENERS DOUBLE ROW OF FASTENERS 12" 12"SPACING PANEL EDGE 3 4"SPACING 12" 5 S402 DETAIL NOT TO SCALE SPACING (SINGLE ROW SHOWN) 3 4"PANEL EDGE SHEATHING SPLICE PLATE A A 2x FLAT-WISE BLOCKING SHEATHING SPLICE PLATE, SAME THICKNESS AND FACE GRAIN ORIENTATION AS SHEATHING SECTION A-A 7 S402 SHEATHING SPLICE PLATE (ALTERNATE DETAIL) NOT TO SCALE 6 S402 DETAIL NOT TO SCALE 312" 112" STRUCTURAL DETAILS SHEET TITLE PROJECT No. DATE REV. No.DATENARRATIVE 0ISSUED FOR PERMIT MEMORY MATTERS RENOVATION AND ADDITION 15 TRELLIS COURT HILTON HEAD ISLAND, SOUTH CAROLINA 26-562 06-05-2026 SHEET No. STRUCTURAL DESIGN CONSULTANTS S402 No. 7089 SOUTH CAROLINA SHEARLOCK ENGINEERING, LLC CE NOITA RI TFICATE ZIRO OF HT AU 06-05-2026 1 UPDATED PER EXISTING CONDITIONS 07-21-2026 No. 33500 REGISTERED PROFESSIONAL ENGINEER SOUTH CAROLINA JAKE EAVENSON 10/19/2023 07/21/2026 Page 38 of 69 © LONDONO Page 39 of 69 © LONDONO Page 40 of 69 © LONDONO Page 41 of 69 © LONDONO Page 42 of 69 © LONDONO Page 43 of 69 © LONDONO Page 44 of 69 © LONDONO Page 45 of 69 © LONDONO Page 46 of 69 © LONDONO Page 47 of 69 © LONDONO Page 48 of 69 © LONDONO Page 49 of 69 MEMORY MATTERS RENOV AION 15 TRELLIS COURT SITE PLANS Page 50 of 69 COVER SHEET ANDPROJECT NOTES SHEET INDEX ALL ARCHITECTURALINFORMATION WAS TAKEN FROMDIGITAL FILES PROVIDED BY:PDG ARCHITECTSHILTON HEAD ISLAND, SC.(843) 785.5171 3 DAYS BEFORE DIGGINGCALL TOLL FREE1-888-721-7877A ONE-CALL SYSTEM FOR COMMUNITY AND JOB SAFETYUTILITY PROTECTION CENTER****CAUTION****CS PROJECT TEAMARCHITECTUREWITMER JONES KEEFERBLUFFTON, SC(843) 757.7411LANDSCAPE ARCHITECTISSUED:JULY 29, 2026 SITE DEVELOPMENT PLANSFORMEMORY MATTERSHILTON HEAD ISLAND, SOUTH CAROLINA DRAWING NUMBERDRAWING TITLE DESIGN CONCEPTS, DRAWING, SHEETS,LOGOS, SPECIFICATIONS, DETAILS,WRITTEN MATERIAL SHALL NOT BE USEDOR REPRODUCED IN WHOLE OR IN PARTIN ANY FORM WITHOUT PRIOR WRITTENCONSENT OF WJK LTD.© 2026 WJK LTD.THIS SHEET TO SCALE AT: 24"X36" DATE:PROJECT NO.:DRAWN BY:CHECKED BY:JUL 29, 202626056.01SDJC REVISIONS:DRB SUBMITTALPLAN, NOT FORCONSTRUCTION CS-L10-L11-L50-L200-L300-L400 -L500-L501-L600-L601 -L602 -COVER SHEETEXISTING CONDITIONSEXISTING CONDITIONS - PHOTOSDEMOLITION PLANLAYOUT PLANGRADING PLANUTILITY PLANPLANTING PLANPLANT SCHEDULE AND DETAILSSITE DETAILS - 01SITE DETAILS - 02SITE DETAILS - 03 1.ALL NOTES APPLY TO ALL DRAWINGS AND ALL TRADES.2.REFER TO ENGINEERING PLANS FOR LAYOUT AND LOCATION OF UTILITIES AND ROADS.3.ALL SURVEY AND SITE INFORMATION WERE COMPILED FROM A VARIETY OF SOURCES AT VARIOUS TIMES.SITE INFORMATION MUST BE FIELD VERIFIED BEFORE CONSTRUCTION BEGINS. REPORT ANY DISCREPANCIES TO THE OWNER OR OWNER'S REPRESENTATIVE.4.IT IS THE RESPONSIBILITY OF ALL CONTRACTORS AND TRADES TO COORDINATE THE INSTALLATION OF THEIR WORK WITH THE INSTALLATION OF WORK BY ALL OTHER CONTRACTORS AND TRADES.5.THE REQUIREMENTS OF THE SPECIFICATIONS, DRAWINGS, GENERAL REQUIREMENTS, AND ALL ITEMS OF THE CONTRACT DOCUMENTS ARE EQUALLY BINDING FOR ALL CONTRACTORS AND TRADES.6.EACH CONTRACTOR IS REQUIRED TO MAINTAIN FULL (COLOR) SETS OF THE CONTRACT DOCUMENTSFOR HIS EMPLOYEES USE ON THE PROJECT TO ASSURE THAT ALL WORK IS PROPERLY COORDINATEDAND FOR REVIEWS BY COUNTY AND / OR MUNICIPALITY OFFICIALS FOR INSPECTIONS.7.ALL CONTRACTORS AND ALL TRADES ARE RESPONSIBLE FOR OBTAINING THE CORRECT PERMITS AND INSPECTIONS PRIOR TO CONSTRUCTION AS REQUIRED BY LOCAL PLANNING, ZONING, BUILDING CODEAND OTHER TOWN AUTHORITIES.8.W.J.K. LTD., THE OWNER AND / OR THE OWNER'S REPRESENTATIVE SHALL BE NOTIFIED OF ANY SITE CONDITIONS WHICH MAY NECESSITATE MODIFICATION TO THE PLAN. THE OWNER OR OWNER'SREPRESENTATIVE SHALL MAKE 'INFIELD MODIFICATIONS,' IF NECESSARY.9.CONTRACTOR SHALL PROVIDE AND FURNISH ALL MATERIALS, EQUIPMENT AND LABOR NECESSARY FOR ALL CONSTRUCTION, PROTECTION, MAINTENANCE AND RELATED ITEMS TO COMPLETE WORKINDICATED ON THE DRAWINGS.10.BEFORE COMMENCING ANY WORK CONTRACTOR SHALL ASCERTAIN THE LOCATION OF ALL UTILITIES,SUB-SURFACE DRAINAGE, AND UNDERGROUND CONSTRUCTION SO THAT PROPER PRECAUTIONS MAY BE TAKEN NOT TO DISTURB ANY SUB-SURFACE IMPROVEMENTS. CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS IN BRINGING EQUIPMENT ON TO AND OFF OF THE SITE, PROTECTING WALKS,PAVING, STEPS AND OTHER EXISTING CONSTRICTION ON THE SITE. CONTACTS SHALL BE MADE BY CONTRACTOR WITH PROPER AUTHORITIES BEFORE AND DURING THIS WORK SO AS TO COMPLY WITH ALL REGULATIONS AND ORDINANCES.11.CONTRACTOR SHALL FIELD LOCATE ALL UTILITIES AND CONFIRM / DETERMINE UTILITY ELEVATIONSPRIOR TO CONSTRUCTION. CONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE AND MAKE REPAIRS, AT THEIR OWN EXPENSE, THAT MAY OCCUR TO EXISTING UTILITIES IN ACCORDANCE WITH NATIONAL,STATE AND LOCAL CODES.12.CONTRACTOR SHALL VERIFY ALL EXISTING TREE CONDITIONS AND ELEVATIONS PRIOR TO CONSTRUCTION. CONTRACTOR SHALL NOTIFY THE OWNER OR OWNER'S REPRESENTATIVE OF ANY DISCREPANCIES PRIOR TO THEIR REMOVAL.13.CONTRACTOR SHALL PROTECT AND INSTALL TREE PROTECTION FENCE AROUND THE DRIP LINE OF ALL TREES, NATURAL AREAS AND EXISTING VEGETATION TO REMAIN. TREE PROTECTION LOCATION SHALLBE APPROVED BY LANDSCAPE ARCHITECT PRIOR TO CONSTRUCTION.14.ALL CONSTRUCTION FOR ALL TRADES SHALL CONFORM TO OR EXCEED THE PRODUCTMANUFACTURER'S RECOMMENDATIONS, REGULATIONS OF THE TOWN OF HILTON HEAD AND THE AMERICANS WITH DISABILITIES ACT, AND / OR OTHER APPLICABLE NATIONAL, STATE, AND LOCALCODES AND ANY OTHER GOVERNING AUTHORITIES.15.CONTRACTOR ACCESS FOR CONSTRUCTION AS DIRECTED BY THE OWNER OR OWNER'S REPRESENTATIVE.16.CONTRACTOR SHALL PROTECT THE GENERAL PUBLIC FROM CONSTRUCTION AREAS DURINGCONSTRUCTION.17.THE OWNER MAY REQUIRE FLAG MEN TO BE AVAILABLE DURING THE CONSTRUCTION PROCESS.18.ANY DEVIATIONS FROM THESE PLANS MUST BE SPECIFICALLY APPROVED BY W.J.K. LTD., AND THE OWNER OR OWNER'S REPRESENTATIVE. GENERAL NOTES: 1.THE CONTRACTOR, BEFORE BEGINNING ANY DEMOLITION ACTIVITY, SHALL CONTACT THE LOCALUTILITIES FOR INSTRUCTION ON SPECIAL PROCEDURES THAT MAY BE REQUIRED BY THE UTILITIESCONCERNING DEMOLITION.2.ALL DEMOLISHED MATERIAL SHALL BE HAULED AWAY AND DISPOSED OF PROPERLY IN A LANDFILL AS APPLICABLE PER TOWN OF HILTON HEAD CODE(S).3.THE CONTRACTOR SHALL FOLLOW ALL REQUIREMENTS OF LOCAL, STATE AND FEDERAL REGULATORYAGENCIES WHICH MAY HAVE JURISDICTION OVER SUCH ACTIVITIES.4.THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL DATA PROVIDED IN THESE DRAWINGS. THE CONTRACTOR SHALL PERFORM HIS OWN ESTIMATE OF MATERIAL FOR DEMOLITION AND REPORT ANY DISCREPANCIES TO THE OWNER OR THE OWNER'S REPRESENTATIVE PRIOR TO BEGINNING WORK.5.ALL UTILITIES SHOWN ON THE DRAWINGS ARE APPROXIMATE AND FOR ESTIMATING PURPOSES ONLY.THE EXACT LOCATIONS SHALL BE FIELD VERIFIED BY THE CONTRACTOR PRIOR TO BEGINNINGDEMOLITION WORK. ALL UTILITIES SHALL BE LOCATED AND PROTECTED TO PREVENT DAMAGE. ANY DAMAGE WHICH MAY OCCUR DURING THE CONSTRUCTION PROCESS IS TO BE PROMPTLY REPORTED TO THE APPROPRIATE UTILITY AUTHORITY AND REPAIRS SHALL BE MADE IN ACCORDANCE WITH THEIRREQUIREMENTS. THE SAFE DEMOLITION AND REMOVAL OF UTILITIES, STRUCTURES AND EQUIPMENT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR.6.IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO NOTIFY, AT THE DIRECTION OF THE OWNER OR OWNER'S REPRESENTATIVE, THE UTILITIES HAVING JURISDICTION OVER ANY UTILITY EASEMENTS OF ANY KIND FOR APPROVAL OF WORK WITHIN THE EASEMENT.7.REMOVAL OF ANY AND ALL MATERIALS INDICATED INCLUDES ALL MATERIALS ASSOCIATED WITH THAT ITEM INCLUDING SUBSURFACE MATERIAL, IF APPLICABLE, NOT NEEDED OR IN NEED OF REPAIR OR REPLACEMENT.8.THE CONTRACTOR SHALL TAKE CARE WHEN WORKING AROUND EXISTING TREES SCHEDULED TO REMAIN. PROPER TREE PROTECTION IN ACCORDANCE WITH LOCAL CODES SHALL BE MADE PRIOR TO CONSTRUCTION BEGINNING AND THROUGHOUT THE CONSTRUCTION PROCESS.9.SOME TREES AND SHRUBS SCHEDULED FOR RELOCATION AND REUSE ON THE PROPERTY MAY NOT BE SALVAGEABLE DUE TO UNDERGROUND UTILITIES.10.BARRIERS AND / OR FLAG MEN MAY BE REQUIRED FOR SAFETY, VERIFY REQUIREMENTS WITH THE OWNER FOR SUCH NEEDS PRIOR TO BEGINNING THE WORK.11.THE OWNER SHALL BE NOTIFIED AS TO THE TIMING OF THE WORK SO THAT PROPER SECURITYNOTIFICATION IS MADE. DEMOLITION NOTES: 1.ALL CONSTRUCTION STAKING SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR.2.CONTRACTOR TO USE DIGITAL FILES PROVIDED BY WITMER-JONES-KEEFER, LTD. TO LAYOUT AND STAKEALL SITE IMPROVEMENTS AND ELEMENTS. FINAL LAYOUT AND STAKING TO BE FIELD VERIFIED AND APPROVED BY LANDSCAPE ARCHITECT AND OWNER OR OWNER'S REPRESENTATIVE PRIOR TO CONSTRUCTION.3.CONTRACTOR SHALL FIELD LOCATE, STAKE AND USE COLOR CODED SPRAY PAINT FOR ALL ABOVE AND BELOW GROUND UTILITIES. CONTRACTOR TO CONFIRM / DETERMINE UTILITY ELEVATIONS PRIOR TO CONSTRUCTION. ANY EXISTING UTILITY CONFLICTS WITH SITE IMPROVEMENTS TO BE REPORTED TO OWNER, OWNER'S REPRESENTATIVE AND LANDSCAPE ARCHITECT PRIOR TO CONSTRUCTION.CONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE TO EXISTING UTILITIES AS STATED IN THE GENERALNOTES.4.ALL SITE IMPROVEMENTS REPRESENTED IN THIS SET OF PLANS SHALL BE STAKED AND REVIEWED WITH THE OWNER OR OWNER'S REPRESENTATIVE PRIOR TO CONSTRUCTION. ANY DISCREPANCIES TO BE REPORTED TO THE OWNER, OWNER'S REPRESENTATIVE OR LANDSCAPE ARCHITECT.5.ALL DIMENSIONS ARE TO EDGE OF PAVING AND CENTERLINE OF WALLS AND COLUMNS UNLESSOTHERWISE INDICATED.6.ALL ANGLES ARE 90 UNLESS OTHERWISE INDICATED.7.CONTRACTOR SHALL PROVIDE LIGHTING, IRRIGATION AND ANY OTHER CONDUIT NEEDED TO ALL LANDSCAPE AREAS.8.ANY AND ALL FIELD ADJUSTMENTS SHALL RECEIVE APPROVAL FROM THE OWNER, OWNER'SREPRESENTATIVE OR LANDSCAPE ARCHITECT PRIOR TO CONSTRUCTION. LAYOUT NOTES: GRADING NOTES: 1.THE INTENT OF THE LIGHTING DESIGN IS TO PROVIDE LOW LEVEL UNOBTRUSIVE SITE LIGHTING OR ARCHITECTURAL ELEMENTS. THE CONTRACTOR SHALL MAKE EVERY EFFORT TO CREATE THIS EFFECT BY CLOSE COORDINATION WITH THE LANDSCAPE ARCHITECT AND CAREFUL PLACEMENT OF ALL FIXTURES.2.THE CONTRACTOR SHALL ENGINEER THE ELECTRICAL SYSTEM BASED ON THE LOCATION AND TYPE OF FIXTURES AS SHOWN ON THE PLAN. PROPERLY SIZED WIRING, TRANSFORMERS, BREAKERS, ACCESSORIES,ETC., SHALL BE PROVIDED BY THE CONTRACTOR AS NECESSARY TO GUARANTEE A COMPLETELYFUNCTIONAL LIGHTING, DISTRIBUTION AND CONTROL SYSTEM.3.CONTRACTOR TO PROVIDE ELECTRICAL PLANS AND SHOP DRAWINGS FOR REVIEW AND APPROVAL BY THE LANDSCAPE ARCHITECT AND OWNER OR OWNER'S REPRESENTATIVE PRIOR TO INSTALLATION.4.ALL LIGHTING EQUIPMENT SHALL BE INSTALLED PER MANUFACTURERS INSTRUCTIONS AND RECOMMENDATIONS, AND MUST COMPLY WITH ALL APPLICABLE STATE AND COUNTY CODES.5.THE CONTRACTOR IS RESPONSIBLE FOR ACQUIRING ALL NECESSARY PERMITS AND INSPECTION / APPROVALS REQUIRED.6.THE CONTRACTOR SHALL STAKE OUT ALL LIGHT FIXTURE AND TRANSFORMER LOCATIONS FOR APPROVAL BY THE LANDSCAPE ARCHITECT, OWNER, OR OWNER'S REPRESENTATIVE PRIOR TO INSTALLATION. EXACT LOCATIONS OF CONTROLLERS, ELECTRICAL PANELS, ETC. TO BE COORDINATEDWITH AND APPROVED BY OWNER, OWNER'S REPRESENTATIVE OR LANDSCAPE ARCHITECT.7.FINAL AIMING AND ADJUSTMENT SHALL BE MADE AT NIGHT WITH LANDSCAPE ARCHITECT PRESENT TO GIVE FINAL APPROVAL.8.THE CONTRACTOR SHALL COORDINATE, STAKE AND FLAG ALL LOCATIONS WHERE ELECTRICALCONDUIT OR P.V.C. SLEEVING MAY BE REQUIRED BENEATH WALKS OR OTHER PAVED AREAS PRIOR TO HARDSCAPE INSTALLATION.9.ALL ELECTRICAL WIRING RUNNING UNDER PAVED AREAS SHALL BE PLACED IN ELECTRICAL CONDUIT OR PVC SLEEVES PROVIDED BY CONTRACTOR.10.CONTRACTOR SHALL RUN ALL NECESSARY ELECTRICAL WIRING TO UTILITY PANEL AND TRANSFORMER.11.CONTRACTOR SHALL PROVIDE A MINIMUM OF 36" OF BURIES EXCESS CABLE AT EACH FIXTURE TO ALLOW FOR FIXTURE ADJUSTMENT.12.ALL LIGHTING TO BE PLACED ON AN APPROPRIATE TIMER. THE CONTRACTOR SHALL SELECT AN APPROPRIATE TIMER FOR ALL LIGHTS AND SET THE TIME APPROPRIATELY FOR PROPER NIGHT TIME ILLUMINATION, FOR APPROVAL BY OWNER OR OWNER'S REPRESENTATIVE.13.CONTRACTOR SHALL PROVIDE GROUND FAULT CIRCUIT BREAKERS FOR ALL CIRCUITS AS REQUIRED BY NATIONAL, STATE AND LOCAL CODES.14.THE CONTRACTOR SHALL PROVIDE ALL EQUIPMENT, LABOR, EXCAVATION AND BACKFILL NECESSARY TO COMPLETE THE WORK.15.ALL FIXTURES PER MODELS SPECIFIED UNLESS CONTRACTOR GETS APPROVAL FROM LANDSCAPEARCHITECT FOR A SUBSTITUTION.16.SYSTEM INSTALLATION, INCLUDING PARTS AND LABOR, SHALL BE GUARANTEED AND REPAIRED AS NECESSARY BY THE CONTRACTOR FOR ONE YEAR.17.CONTRACTOR TO PROVIDE "AS-BUILT" DRAWINGS IMMEDIATELY AFTER FINAL ACCEPTANCE, ALONGWITH ALL INSTRUCTION MANUALS FOR ALL EQUIPMENT INSTALLED.18.IF POSSIBLE, FIELD MODIFICATIONS WILL BE DIRECTED BY THE LANDSCAPE ARCHITECT, OWNER OR OWNER'S REPRESENTATIVE. LIGHTING NOTES: 1.ALL CONTRACTORS AND ALL TRADES ARE RESPONSIBLE FOR OBTAINING THE CORRECT PERMITS AND INSPECTIONS PRIOR TO CONSTRUCTION AS REQUIRED BY LOCAL PLANNING, ZONING, BUILDING CODEAND OTHER TOWN AUTHORITIES.2.CONTRACTOR SHALL PROVIDE SAMPLES OF ALL MATERIALS AND OBTAIN APPROVAL FROM OWNER,OWNER'S REPRESENTATIVE OR LANDSCAPE ARCHITECT PRIOR TO CONSTRUCTION.3.ON SITE TOPOGRAPHY MAY REQUIRE ADJUSTMENTS OF FINAL SPOT ELEVATIONS ON SITE FOR PROPOSED VERTICAL CONSTRUCTION ELEMENTS. THE CONTRACTOR SHALL NOTIFY THE OWNER OR OWNER'S REPRESENTATIVE PROMPTLY UPON THE DISCOVERY OF ANY SUCH REQUIRED ADJUSTMENTS.4.THE CONTRACTOR SHALL PROVIDE FILL AS IS REQUIRED TO OBTAIN PROPER RELATIONSHIP OF FOOTINGTO FINISH GRADE REQUIREMENTS - FEATHER FILL TO ADJACENT EXISTING GRADE TO ASSURE A COORDINATED AND DESIRED EFFECT.5.THE CONTRACTOR IS RESPONSIBLE FOR ALL DAMAGE TO EXISTING CONDITIONS SCHEDULED TO REMAINDURING CONSTRUCTION.6.THE CONTRACTOR IS RESPONSIBLE FOR LOCATING ALL EXISTING UTILITIES AND FOR ANY DAMAGE THAT MAY OCCUR TO EXISTING UTILITIES DURING CONSTRUCTION.7.'IN-FIELD MODIFICATIONS' MAY BE NECESSARY TO PRODUCE DESIRED EFFECT. MODIFICATIONS TO BE APPROVED BY LANDSCAPE ARCHITECT AND OWNER OR OWNER'S REPRESENTATIVE.8.ALL WELDS TO BE CONTINUOUS.9.FOR ALL WOOD MEMBERS, ALL CUTS SHALL BE EVEN AND JOINTS FLUSH. SAND FOUR SIDES AND FILL IMPERFECTIONS, COUNTERSINKS AND NAIL HOLES TO ASSURE EVEN FINISH.10.CONTRACTOR SHALL VERIFY ALL WOOD MEMBERS FOR APPROPRIATE SIZE, SPACING, ATTACHMENTSAND STRUCTURAL STABILITY PRIOR TO CONSTRUCTION. CONTRACTOR TO REPORT ANY DISCREPANCIESTO OWNER, OWNER'S REPRESENTATIVE OR LANDSCAPE ARCHITECT.11.ALL NOTCHES SHALL BE SHOP CUT TO ASSURE TIGHT JOINTS. EACH MEMBER SHALL BE DRIVEN HOMETO ASSURE TIGHT FIT. PILOT HOLES SHALL BE DRILLED FOR EACH CARRIAGE BOLT. PLUG, SEAL AND PRIME.12.FINISH ALL SIDES AND CAULK ALL JOINTS WITH APPROPRIATE EXTERIOR CAULK PRIOR TO FINISHING.13.ALL CONNECTORS, UNLESS OTHERWISE SPECIFIED, SHALL BE STAINLESS STEEL. BOLTS, THREADED RODS,WASHERS, NUTS AND ALL BUILDING HARDWARE SHALL BE STAINLESS STEEL AND SUITABLE FOR PRESSURE TREATED WOOD. ALL THROUGH BOLTS TO BE SMOOTH SHAFT WITH STAINLESS STEEL NUTS,BOLTS AND WASHERS. ALL NAILS AND FINISH NAILS SHALL BE ANNULAR STAINLESS STEEL.14.ALL DECKING SHALL BE SECURED WITH STAINLESS STEEL SCREWS SIZED FOR DECK APPLICATION.MINIMUM 3" APART. CONSTRUCTION NOTES: PLANTING NOTES:1.CONTRACTOR IS RESPONSIBLE FOR INSPECTION OF EXISTING CONDITIONS, INCLUDING UTILITIES, AND PROMPTLY REPORTING ANY DISCREPANCIES OR CONFLICTS WITH PLANTING AREAS. REPORTINFORMATION TO OWNER, OWNER'S REPRESENTATIVE AND LANDSCAPE ARCHITECT.2.CONTRACTOR SHALL FIELD LOCATE ALL UTILITIES. CONTRACTOR IS RESPONSIBLE FOR ANY DAMAGEAND MAKE REPAIRS THAT MAY OCCUR TO EXISTING UTILITIES IN ACCORDANCE WITH NATIONAL, STATEAND LOCAL CODES.3.LANDSCAPE PLANTING AND / OR MULCHED AREAS TO BE FINE GRADED, HAND RAKED SMOOTH AND FREE OF DEBRIS.4.CONTRACTOR TO PERFORM SOIL TESTS AS NECESSARY TO ASSURE PLANT HEALTH AND GROWTH.5.MULCH ALL PLANTING BEDS TO A MIN. 3" DEPTH WITH MULCH SPECIFIED IN PLANT SCHEDULE.6.CONTRACTOR VERIFIES THAT ALL PLANT MATERIAL IS DETERMINED AVAILABLE AS SPECIFIED WHEN BID / PROPOSAL IS SUBMITTED.7.PLANT SCHEDULE WAS PREPARED FOR ESTIMATING PURPOSES ONLY. CONTRACTOR SHALL MAKE OWN QUANTITY TAKEOFFS USING DRAWINGS TO DETERMINE QUANTITIES TO HIS SATISFACTION, REPORTINGPROMPTLY ANY DISCREPANCIES WHICH MAY AFFECT BIDDING.8.GALLON SIZES ARE FOR PRICING PURPOSES ONLY. PLANT MUST MEET HEIGHTS AND WIDTHS SPECIFIEDIN PLANT SCHEDULE.9.ROOT TYPE MAY BE FREELY SUBSTITUTED IN CASE OF BALLED AND BURLAPPED OR CONTAINER GROWN,OTHER SPECIFICATIONS REMAINING UNCHANGED, EXCEPT IN THE CASE OF CONTAINER GROWNSPECIMEN TREES AS INDICATED IN THE TREE PLANTING SCHEDULE.10.ANY SIGNIFICANT ROOTS ENCOUNTERED 2" DIA. AND LARGER SHALL BE DUG OUT BY HAND AND CLEANLY CUT BACK IN THE FOOTING / FOUNDATION AREA TO PROMOTE ROOT RE-GROWTH AND HELP PREVENT ROOT DIEBACK.11.ALL PLANT MATERIAL (EXCEPT SEASONAL COLOR) SHALL BE GUARANTEED AND REPLACED AS NECESSARY BY THE CONTRACTOR FOR ONE YEAR.12.ALL SEASONAL COLOR SHALL BE GUARANTEED AND REPLACED AS NECESSARY BY THE CONTRACTORFOR THREE MONTH TIME FRAMES. IRRIGATION NOTES: TURF AND GRASSING NOTES: 1.CONTRACTOR TO SUPPLY AUTOMATIC IRRIGATION SYSTEM, COMPLETE AND INSTALLED. SYSTEM TO INCLUDE ALL VALVES, PIPES, HEADS, FITTINGS, BACK FLOW CONTROLLER, AND IRRIGATION METER AND TO PROVIDE 100% COVERAGE FOR ALL NEW PLANTINGS. DRIP IRRIGATION TO BE USED FOR ALL PLANTINGS, EXCEPT LAWNS.2.NO IRRIGATION COMPONENTS SHALL BE CLOSER THAN 12" TO ANY EDGE OF PAVEMENT OR CURB AND GUTTER. IRRIGATION SHALL NOT SPRAY BEYOND LANDSCAPED AREAS, OR INTO ANY UNDISTURBEDBUFFERS. NO OVER SPRAY SHALL BE PERMITTED ONTO ADJACENT PROPERTIES OR PEDESTRIANSIDEWALK AREAS.3.LANDSCAPE CONTRACTOR TO FIELD VERIFY ALL COMPONENT LOCATIONS TO ENSURE APPROPRIATECOVERAGE.4.LANDSCAPE CONTRACTOR SHALL LOCATE WATER SOURCE AND PROVIDE POWER TO CONTROLLER.5.CONTROLLER LOCATION TO BE SPECIFIED BY OWNERS REPRESENTATIVE IN FIELD PRIOR TO CONSTRUCTION.6.ALL DRIP TUBING SHALL BE COVERED WITH MIN. 3" OF MULCH.7.ALL DRIP AND SPRAY ZONES SHALL BE SEPARATE.8.CONTRACTOR SHALL SUBMIT FINAL IRRIGATION PLANS TO OWNER'S REPRESENTATIVE AND ALL REVIEWING BODIES / AGENCIES FOR FINAL APPROVAL PRIOR TO INSTALLATION. 1.CONTRACTOR SHALL IMPLEMENT ALL SILT FENCE OR OTHER SEDIMENT CONTROL MEASURES AROUNDALL DISTURBED AREAS PRIOR TO ANY CONSTRUCTION ACTIVITIES.2.TEMPORARY CONSTRUCTION ENTRANCE SHALL BE INSTALLED AFTER SILT FENCE AND PRIOR TO ALL OTHER CONSTRUCTION ACTIVITIES.3.ALL SEDIMENT AND EROSION CONTROL DEVICES SHALL BE INSPECTED BY THE CONTRACTOR AT LEASTONCE EVERY FOURTEEN (14) CALENDAR DAYS AND WITHIN 24 HOURS OF THE END OF A STORM EVENTOF 0.5 INCHES OR GREATER. IF SITE INSPECTIONS IDENTIFY B.M.P.S. THAT ARE DAMAGED OR ARE NOT OPERATING EFFECTIVELY, MAINTENANCE MUST BE PERFORMED AS SOON AS PRACTICAL AND BEFORETHE NEXT STORM EVENT IF PRACTICAL.4.CONTRACTOR TO PROVIDE SILT FENCE AND / OR OTHER CONTROL DEVICES, AS MAY BE REQUIRED, TO CONTROL SOIL EROSION DURING UTILITY CONSTRUCTION. ALL DISTURBED AREAS SHALL BE CLEANED,GRADED AND STABILIZED WITH GRASSING IMMEDIATELY AFTER THE UTILITY INSTALLATION. FILL, COVERAND TEMPORARY SEEDING AT THE END OF EACH DAY ARE RECOMMENDED. IF WATER IS ENCOUNTERED WHILE TRENCHING, THE WATER SHOULD BE FILTERED TO REMOVE ANY SEDIMENTSBEFORE BEING PUMPED BACK INTO ANY WATERS OF THE STATE.5.ALL EROSION CONTROL DEVICES SHALL BE PROPERLY MAINTAINED BY THE CONTRACTOR DURING ALL PHASES OF CONSTRUCTION UNTIL THE COMPLETION OF ALL CONSTRUCTION ACTIVITIES AND ALL DISTURBED AREAS HAVE BEEN STABILIZED. ADDITIONAL CONTROL DEVICES MAY BE REQUIRED DURINGCONSTRUCTION IN ORDER TO CONTROL EROSION AND / OR OFFSITE SEDIMENTATION. ALL TEMPORARYCONTROL DEVICES SHALL BE REMOVED ONCE CONSTRUCTION IS COMPLETE AND THE SITE IS STABILIZED.6.THE CONTRACTOR MUST TAKE NECESSARY ACTION TO MINIMIZE THE TRACKING OF MUD ONTO PAVEDSURFACES FROM CONSTRUCTION AREAS AND THE GENERATION OF DUST. THE CONTRACTOR SHALLREMOVE MUD / SOIL DAILY FROM PAVED SURFACES, AS REQUIRED.7.RESIDENTIAL SUBDIVISIONS REQUIRE EROSION CONTROL FEATURES FOR INFRASTRUCTURE AS WELL AS FOR INDIVIDUAL LOT CONSTRUCTION. INDIVIDUAL PROPERTY OWNERS SHALL FOLLOW THESE PLANSDURING CONSTRUCTION OR OBTAIN APPROVAL OF AN INDIVIDUAL PLAN IN ACCORDANCE WITH S.C. REG. 72-300 ET SEQ. AND SCR100000.8.TEMPORARY DIVERSION BERMS AND / OR DITCHES WILL BE PROVIDED AS NEEDED DURINGCONSTRUCTION TO PROTECT WORK AREAS FROM UPSLOPE RUNOFF AND / OR TO DIVERTSEDIMENT-LADEN WATER TO APPROPRIATE TRAPS OR STABLE OUTLETS.9.ALL WATERS OF THE STATE (W.O.S.), INCLUDING WETLANDS, ARE TO BE FLAGGED OR OTHERWISECLEARLY MARKED IN THE FIELD. A DOUBLE ROW OF SILT FENCE IS TO BE INSTALLED IN ALL AREASWHERE A 50-FOOT BUFFER CAN'T BE MAINTAINED BETWEEN THE DISTURBED AREA AND ALL W.O.S. A 10-FOOT BUFFER SHOULD BE MAINTAINED BETWEEN THE LAST ROW OF SILT FENCE AND ALL W.O.S.10.LITTER, CONSTRUCTION DEBRIS, OILS, FUELS AND BUILDING PRODUCTS WITH SIGNIFICANT POTENTIALFOR IMPACT (SUCH AS STOCKPILES OF FRESHLY TREATED LUMBER) AND CONSTRUCTION CHEMICALSTHAT COULD BE EXPOSED TO STORMWATER MUST BE PREVENTED FROM BECOMING A POLLUTANTSOURCE IN STORMWATER DISCHARGES.11.STABILIZATION MEASURES SHALL BE INITIATED AS SOON AS PRACTICAL IN PORTIONS OF THE SITE WHERECONSTRUCTION ACTIVITIES HAVE TEMPORARILY OR PERMANENTLY CEASED, BUT IN NO CASE MORETHAN FOURTEEN (14) DAYS AFTER WORK HAS CEASED EXCEPT AS STATED BELOW:11.1.WHERE STABILIZATION BY THE 14TH DAY IS PRECLUDED BY SNOW COVER OR FROZEN GROUNDCONDITIONS, STABILIZATION MEASURES MUST BE INITIATED AS SOON AS PRACTICAL.11.2.WHERE CONSTRUCTION ACTIVITY ON A PORTION OF THE SITE IS TEMPORARILY CEASED ANDEARTH-DISTUBING ACTIVITIES WILL BE RESUMED WITHIN 14 DAYS, TEMPORARY STABILIZATIONMEASURES DO NOT HAVE TO BE INITIATED ON THAT PORTION OF THE SITE. GENERAL DISTURBANCE NOTES: 1.CONTRACTOR SHALL VERIFY ALL ELEVATIONS PRIOR TO CONSTRUCTION AND NOTIFY OWNER'SREPRESENTATIVE OF DISCREPANCIES.2.CROSS SLOPES ON ALL HARDSCAPE WALKWAYS / PATHWAYS ARE NOT TO EXCEED 2%.3.ALL ACCESSIBLE WALKWAYS / PATHWAYS RUNNING SLOPE (GRADIENT) MAY NOT EXCEED 4.9%, UNLESSA RAMP IS INSTALLED. IF A RAMP IS INSTALLED THE RUNNING SLOPE (GRADIENT) SHALL NOT EXCEED8.33%, AND HANDRAILS SHALL BE INSTALLED ON BOTH SIDES (MINIMUM 36" CLEARANCE BETWEENHANDRAILS) WHEN RAMP RISE IS GREATER THAN 6".4.IF DISCREPANCIES DEVELOP BETWEEN THE PROPOSED GRADES AS SHOWN ON THE PLAN AND THE EXISTING GROUND SURFACE, THE CONTRACTOR, WITH PRIOR APPROVAL FROM THE OWNER'SREPRESENTATIVE, SHALL MAKE GRADING ADJUSTMENTS NECESSARY TO MAINTAIN THE GENERAL INTENTOF THE DESIGN.5.CONTRACTOR IS RESPONSIBLE FOR ALL PAVED AREAS DAMAGED DURING CONSTRUCTION.6.CONTRACTOR SHALL PROVIDE POSITIVE DRAINAGE AWAY FROM ALL ADJACENT PROPERTIES, WALLS,WALKS AND PLANTING BEDS AND TOWARDS EXISTING DRAIN INLETS, SWALES, STORMWATER LAGOONSOR ROADS.7.ALL DISTURBED AREAS INCLUDING SHALLOW SWALES SHALL BE MULCHED OR PLANTED AS INDICATEDON PLANTING PLANS.8.IF REQUIRED, POP UP EMITTER SHALL BE N.D.S. 6" POP UP DRAINAGE EMITTER BLACK IN COLOR.9.LANDSCAPE DRAIN SHALL BE AS SPECIFIED ON PLANS.10.LANDSCAPE DRAINS SHALL BE ADDED TO PROVIDE POSITIVE DRAINAGE AWAY FROM BUILDINGS IN LOW / FLAT AREAS THAT DID NOT SHOW UP ON THE TOPOGRAPHIC SURVEY. LANDSCAPE DRAIN SHALLBE APPROVED BY OWNER, OWNER'S REPRESENTATIVE OR LANDSCAPE ARCHITECT PRIOR TO INSTALLATION. 1.GRASS SEED: PROVIDE FRESH, CLEAN, NEW-CROP SEED COMPLYING WITH TOLERANCE FOR PURITY AND GERMINATION ESTABLISHED BY OFFICIAL SEED ANALYSIS OF NORTH AMERICA. PROVIDE SEED MIXTURECOMPOSED OF GRASS SPECIES, PROPORTIONS AND MINIMUM PERCENTAGES OF PURITY, GERMINATION,AND MAXIMUM PERCENTAGE OF WEED SEED, AS SPECIFIED SEED MANUFACTURER.2.SOD SHALL BE STRONGLY ROOTED AND FREE OF PERNICIOUS WEEDS. ALL NETTING SHALL BE REMOVEDFROM SOD BEFORE IT IS LAID.3.ALL AREAS IN WHICH EARTHWORK SHALL BE SUSPENDED FOR MORE THAN TWO (2) WEEKS SHALL BE GRASSED WITH TEMPORARY GRASS.4.AFTER TOPSOIL HAS BEEN INSTALLED, AND BEFORE ANY SOD IS LAID, CORRECT ALL SOFT SPOTS AND IRREGULARITIES IN GRADE. THE SOD SHALL BE BE LAID BY BUTTING THE ENDS AND SIDES UP EVENLYAND STAGGERING THE ROLLS OF SOD. CONTRACTOR SHALL NOT OVERLAP SOD. AS SOON AS THE SOD IS LAID OR AS IT IS BEING LAID ROLL OVER WITH A LIGHT ROLLER, MAKING CERTAIN THAT ALL OF THE SOD IS IN CONTACT WITH THE SOIL. THE COMPLETED SODDED AREAS SHALL BE TRUE TO FINISH GRADE,EVEN AND FIRM AT ALL POINTS.5.SEED SHALL BE AT A RATE OF 10 POUNDS PER ACRE.6.THIRTY DAYS AFTER LAST SEEDING/SODDING OPERATION, APPLY 1 POUND OF TYPE A NITROGENFERTILIZER PER ACRE OF LAWN AREAS AND IMMEDIATELY WATER.7.UPON COMPLETION OF PLANTINGS ALL EXCESS SOIL STONES AND DEBRIS WHICH HAS NOT PREVIOUSLYBEEN CLEANED UP SHALL BE REMOVED FROM THE SITE AND DISPOSED OF AS DIRECTED BY THE OWNER'S REPRESENTATIVE.8.ALL LAWN AREAS THAT DO NOT SHOW SATISFACTORY GROWTH WITHIN (18) DAYS AFTER PLANTINGSHALL BE RE-PLANTED AND RE-FERTILISZED AS SPECIFIED UNTIL A SATISFACTORY LAWN IS ESTABLISHED.THE LAWN SHALL BE CONSIDERED ESTABLISHED WHEN ITS REASONABLY FREE FROM WEED, GREEN IN APPEARANCE AND THE SPECIFIED GRASS IS VIGOROUS AND GROWING WELL ON EACH SQ. FT. OF LAWNAREA.9.LAWN SHALL BE PROTECTED AND MAINTAINED BY WATERING, MOWING, AND REPLANTING,OVERSEEING, AS NECESSARY FOR AS LONG AS IS NECESSARY TO ESTABLISH A UNIFORM STAND.SCATTERED BARE SPOTS, NONE OF WHICH IS LARGER THAN ONE SQ. FT., WILL BE ALLOWED UP TO MAXIMUM OF THREE PERCENT OF ANY LAWN AREA. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO REPAIR ANY EROSIONAL DAMAGE TO THE LAWN AREA. FULL COVERAGE IS REQUIREDIN SIXTY DAYS.10.MAINTENANCE OF GRASSED AREAS SHALL CONSIST OF MOWING, WATERING AND FERTILIZING. ALL GRASSED AREAS SHALL BE MAINTAINED AT A HEIGHT NOT TO EXCEED 6" ABOVE FINISHED GRADE.11.IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO MAINTAIN ALL GRASSED AREAS UNTIL ACCEPTANCEBY OWNER AT END OF PROJECT. LAWN MAINTENANCE SHALL OCCUR AT A MINIMUM OF ONCE PER SEVEN CALENDAR DAYS.12.FINAL SEEDING AND SOD AREAS / SQUARE FOOTAGES TO BE PAINTED IN FIELD AND APPROVED AND ADJUSTED IN FIELD BY OWNER'S REPRESENTATIVE PRIOR TO INSTALLATION.13.SEEDING SHALL TAKE PLACE IMMEDIATELY AFTER FINE GRADING. MAINTAIN SEEDED LAWN UNTILCOMPLETION AND ACCEPTANCE OF ENTIRE PROJECT.14.SEEDING BED SHALL HAVE TOPSOIL LOOSEN TO A DEPTH OF 4". REMOVE STONE OVER 1" IN ANY DIMENSION, ROOTS, RUBBISH, AND EXTRANEOUS MATTER. 1.TOPSOIL SHALL CONSIST OF THE NATURAL LOAM, SANDY LOAM, SILT LOAM, OR CLAY LOAM HUMUSBEARING SOILS, ADAPTED TO THE SUSTENANCE OF PLANT LIFE, WITH THE FOLLOWING TEXTURE:1.1.ORGANIC MATERIAL - TWO (2) TO TWENTY (20) PERCENT BY MASS1.2.SAND CONTENT - TWENTY (20) TO SIXTY (60) PERCENT BY MASS1.3.CLAY-SILT CONTENT – THIRTY FIVE (35) TO SEVENTY (70) PERCENT BY MASS.1.4.TOPSOIL PH SHALL BE BETWEEN FIVE (5) AND SEVEN (7).2.TOPSOIL SHALL BE OF UNIFORM QUALITY AND FREE FROM FOREIGN MATERIAL SUCH HARD CLODS,SOD, STIFF CLAY, HARD PAN, STONES LARGER THAN ONE (1) INCH DIAMETER, LIME CEMENT, ASHES,SLAG, CONCRETE, TAR RESIDUES, TARRED PAPER, BOARDS, CHIPS, STICKS, OR OTHER UNDESIRABLEMATERIALS. IT SHALL ALSO BE REASONABLY FREE FROM WEEDS AND OBJECTIONABLE PLANT MATERIAL.3.AFTER ALL DEMOLITION, CLEARING AND DISPOSAL IS COMPLETED, THE CONTRACTOR SHALL STRIP FROMTHE TOP OF THE EXISTING GROUND ALL TOPSOIL IN ALL AREAS TO BE GRADED.4.PRIOR TO STOCKPILING OF TOPSOIL, TOPSOIL SHALL BE SCREENED WITH A ONE HALF (1/2) INCH SIZE SIEVE. STOCKPILE TOPSOIL IN DESIGNATED OR APPROVED LOCATIONS WITH PROPER DRAINAGE AND WHERE IT WILL NOT INTERFERE WITH THE WORK. AFTER TOPSOIL HAS BEEN STOCKPILED, CONTRACTORSHALL QUANTIFY THE AMOUNTS AT NO ADDITIONAL COST TO THE OWNER. QUANTITIES SHALL BE GIVEN TO THE ARCHITECT, OWNER AND SITE DESIGN PROFESSIONAL.5.IF AMOUNT OF SCREENED TOPSOIL STOCKPILED FROM STRIPING OPERATIONS IS INSUFFICIENT TO PROVIDE THE NECESSARY AMOUNTS (4" MINIMUM DEPTH), IT SHALL BE THE CONTRACTOR’S RESPONSIBILITY TO OBTAIN (FROM OFF-SITE SOURCE) THE NECESSARY AMOUNT OF SCREENED TOPSOILTO COMPLETE THE PROJECT.6.SCREENED TOPSOIL SHALL BE DISTRIBUTED WITH A MINIMUM DEPTH OF FOUR (4) INCHES TO ALL GRADED AREAS (NOT INCLUDING BUILDING, PAVED, SYNTHETIC TURF, PERVIOUS PAVEMENT, ETC.) AND / OR AS DIRECTED BY THE OWNER OR OWNER'S REPRESENTATIVE. GROUND SHALL BE SCARIFIED BEFOREPLACING TOPSOIL. AREAS WHERE SCREENED TOPSOIL IS DISTRIBUTED SHALL BE STABILIZED WITH TEMPORARY AND/OR PERMANENT VEGETATION (SEASON DEPENDENT) OR TEMPORARY MULCH WITHINFOURTEEN (14) CALENDAR DAYS OF DISTRIBUTION. SOIL AMENDMENT NOTES: Page 51 of 69 26 DBH LIVE OAK (SIGNIFICANT TREE) - EXISTING CANOPY IMPACT: 33%5 9 10 11 13 16 17 DBH LIVE OAK (SPECIMEN TREE) - EXISTING CANOPY IMPACT: 69% 13 16 19 DBH LIVE OAK (SIGNIFICANT TREE) - EXISTING CANOPYIMPACT: 48%26 DBH LIVE OAK (SIGNIFICANT TREE) - EXISTING CANOPY IMPACT: 79%15 22 DBH LIVE OAK (SIGNIFICANT TREE) - EXISTING CANOPY IMPACT: 3%24 DBH LIVE OAK (SIGNIFICANT TREE) - EXISTING CANOPY IMPACT: 12% SPECIMEN AND SIGNIFICANT TREEENCROACHMENT SUMMARY:ABDCE REFERENCE PLANEXISTING CONDITIONS SITE DEVELOPMENT PLANSFORMEMORY MATTERSHILTON HEAD ISLAND, SOUTH CAROLINA DRAWING NUMBERDRAWING TITLE DESIGN CONCEPTS, DRAWING, SHEETS,LOGOS, SPECIFICATIONS, DETAILS,WRITTEN MATERIAL SHALL NOT BE USEDOR REPRODUCED IN WHOLE OR IN PARTIN ANY FORM WITHOUT PRIOR WRITTENCONSENT OF WJK LTD.© 2026 WJK LTD.THIS SHEET TO SCALE AT: 24"X36" DATE:PROJECT NO.:DRAWN BY:CHECKED BY:JUL 29, 202626056.01SDJC REVISIONS:DRB SUBMITTALPLAN, NOT FORCONSTRUCTION L10 MEMORY MATTERSBUILDING 02040608010305070Scale 1 " = 20'cNEW LAGOON PROPERTY LINE20' ADJACENT USE SETBACK PROPERTY LINEBIKE PATH EASEMENT 40' ADJACENT STREET SETBACK PROPERTY LINE PROPERTY LINE 20' ADJACENT STREET SETBACKPROPERTY LINE LOT 17 LOT 19TRELLIS COURT LEG OF MUTTON ROAD MARSHLAND ROAD EXISTING CONDITIONS REFERENCENOTES:1EXISTING PERVIOUS SURFACE (LANDSCAPE AREAS).EXISTING PERVIOUS SURFACE - PERVIOUS PAVERS.EXISTING IMPERVIOUS SURFACE - CONCRETE.ENTRY AND EXIT LANE.EXISTING DOCK.EXISTING BULKHEAD.EXISTING PLANTER.EXISTING UTILITIES.FLOOD ZONE.EXISTING STORM PIPE. 2345678PROJECT INFORMATION:ZONINGZONING DISTRICT: LIGHT INDUSTRIAL (IL)OVERLAY DISTRICT: OCRM HIGH TIDE LINE (COR)USE OF PROPERTY: OTHER COMMERCIALSITEGROSS SITE ACREAGE: 2.39 ACNET SITE ACREAGE: 2.39 ACAREA OF DISTURBANCE: <0.5 ACDENSITYALLOWED TOTAL DENSITY: 23,900 GFA (10,000 GFA PER ACRE)EXISTING BUILDING SQUARE FOOTAGE: +/- 7,970PROPOSED BUILDING SQUARE FOOTAGE: +/- 8,635BUILDING HEIGHTMAXIMUM HEIGHT ALLOWED: 35'PROPOSED BUILDING HEIGHT: AS EXISTING <35'SITE IMPERVIOUSMAXIMUM ALLOWED IMPERVIOUS AREA: 67,546 SF (65% OF SITE)CURRENT IMPERVIOUS AREA: 52,132 SF (50% OF SITE)PROPOSED IMPERVIOUS AREA: 55,939 SF (54%)PARKINGMINIMUM NUMBER OF PARKING SPACES REQUIRED: 1 PER 350 GFAEXISTING NUMBER OF PARKING SPACES: 22PROPOSED NUMBER OF PARKING SPACES: 22FLOOD ZONE ZONE 'X-SHADED' SHOWN ON HHI FEMA 2021 MAP EXISTINGPARKING EXISTINGUNLOADZONE BIKE PATH EXISTING GRAVELPAD / SITTING AREA 1 2 3 5 68 9 79 TREE IMPACT LEGENDSYMBOLDESCRIPTIONTREE CANOPY - SPECIMENSPECIMEN TREE IMPACTS - EXISTINGSIGNIFICANT TREE IMPACTS - EXISTINGNOTE: HATCHES ARE GRAPHIC IN NATURE AND ARE NOT INTENDED TO BE TO SCALE.LOWEST LIMB WITH CLEARANCE FROM GRADE+12'TREE CANOPY - SIGNIFICANT A BDC EF F EXISTINGSTORMPAVERS 40' ADJACENT STREET SETBACK 20' ADJACENT USE SETBACK SOUTHERN BOUNDARY (325 LF) - MARSHLAND ROADTYPE 'B' OPTION 1 (25') MINOR ARTERIAL BUFFER WESTERN BOUNDARY (139 LF) - LEG OF MUTTON ROADTYPE 'B' OPTION 1 (25') MINOR ARTERIAL BUFFER NORTHWESTERN BOUNDARY (282 LF) - SHARED INDUSTRIAL (IL ZONING) PROPERTYLINENO EXTERIOR BOUNDARY BUFFER REQUIRED 4NORTHERN BOUNDARY(90 LF) - TRELIS COURTTYPE 'A' OPTION 1 (20')ADJACENTSTREET BUFFEREASTERN BOUNDARY (235 LF) - SHARED INDUSTRIAL (IL ZONING) PROPERTY LINENO EXTERIOR BOUNDARY BUFFER REQUIRED 10 10 EXISTINGVEGETATIONTO REMAIN, TYP. EXISTINGVEGETATIONTO REMAIN, TYP. Page 52 of 69 SITE PHOTOSEXISTING CONDITIONS SITE DEVELOPMENT PLANSFORMEMORY MATTERSHILTON HEAD ISLAND, SOUTH CAROLINA DRAWING NUMBERDRAWING TITLE DESIGN CONCEPTS, DRAWING, SHEETS,LOGOS, SPECIFICATIONS, DETAILS,WRITTEN MATERIAL SHALL NOT BE USEDOR REPRODUCED IN WHOLE OR IN PARTIN ANY FORM WITHOUT PRIOR WRITTENCONSENT OF WJK LTD.© 2026 WJK LTD.THIS SHEET TO SCALE AT: 24"X36" DATE:PROJECT NO.:DRAWN BY:CHECKED BY:JUL 29, 202626056.01SDJC REVISIONS:DRB SUBMITTALPLAN, NOT FORCONSTRUCTION L11 MEMORY MATTERSBUILDING cNEW LAGOON PROPERTY LINE20' ADJACENT USE SETBACK PROPERTY LINEBIKE PATH EASEMENT 40' ADJACENT STREET SETBACK PROPERTY LINE PROPERTY LINE 20' ADJACENT STREET SETBACKPROPERTY LINE LOT 17 LOT 19TRELLIS COURT LEG OF MUTTON ROAD MARSHLAND ROAD EXISTINGPARKING EXISTINGUNLOADZONE BIKE PATH 40' ADJACENT STREET SETBACK 20' ADJACENT USE SETBACK EXISTINGVEGETATIONTO REMAIN, TYP. EXISTINGVEGETATIONTO REMAIN, TYP. EXISTINGPARKING 040801201602060100140Scale 1 " = 40' 1ONLY VIEW INTO SITE FROM MARSHLAND ROAD 4VIEW INTO SITE FROM TRELLIS COURT ENTRY 2INTERNAL VIEW TO MARSHLAND ROAD 5BUILDING FRONTAGE AND PARKING LOT LIVE OAKS 3INTERNAL VIEW TO LEG O'MUTTON ROAD 6BUILDING FRONT AND PERVIOUS PARKING 7LAGOON BULKHEAD WALL8FUTURE GARDEN SPACE AND WATER OAK TO REMAIN 9PERVIOUS PARKING SURFACE10BUILDING FRONTAGE 1 23 45 7 8106 Page 53 of 69 G DEMOLITION PLANL50 SITE DEVELOPMENT PLANSFORMEMORY MATTERSHILTON HEAD ISLAND, SOUTH CAROLINA DRAWING NUMBERDRAWING TITLE DESIGN CONCEPTS, DRAWING, SHEETS,LOGOS, SPECIFICATIONS, DETAILS,WRITTEN MATERIAL SHALL NOT BE USEDOR REPRODUCED IN WHOLE OR IN PARTIN ANY FORM WITHOUT PRIOR WRITTENCONSENT OF WJK LTD.© 2026 WJK LTD.THIS SHEET TO SCALE AT: 24"X36" DATE:PROJECT NO.:DRAWN BY:CHECKED BY:JUL 29, 202626056.01SDJC REVISIONS:DRB SUBMITTALPLAN, NOT FORCONSTRUCTION MEMORY MATTERSBUILDING LAGOON PROPERTY LINE PROPERTY LINEBIKE PATH EASEMENT PROPERTY LINE PROPERTY LINE PROPERTY LINE LOT 17 LOT 19TRELLIS COURT LEG OF MUTTON ROAD MARSHLAND ROAD cNEW02040608010305070Scale 1 " = 20' SITE DEMOLITION LEGENDSYMB.DESCRIPTIONTREE TO BE REMOVED- SEE SHEET L500 & L501 FOR MITIGATIONCALL-OUTNOTE: DEMOLITION HATCHES ARE GRAPHIC IN NATURE AND ARE NOT INTENDED TO BE TOSCALE.2.2SILT FENCE2.12.3DEMOLITION LIMITS PLANT PROTECTION LEGENDSYMB.DETAILDESCRIPTIONCALL-OUT1.1TREE PROTECTION FENCE - WOOD1/L6001.2TREE PROTECTION FENCE - ALT (ORANGE)1/L600 DEMOLITION REFERENCE NOTES:1PROTECT EXISTING PAVEMENT(S) DURING CONSTRUCTION.PAVEMENT TO BE MAINTAINED AND INTEGRATED WITH NEWCONSTRUCTION.EXISTING TREE TO REMAIN, DO NOT DISTURB, PROTECT IN PLACE.REVIEW HEALTH OF EXISTING TREE WITH ARBORIST PRIOR TOREMOVAL OF EXISTING PAVEMENT WITHIN DRIP LINE. FOLLOWARBORISTS INSTRUCTION FOR PAVEMENT REMOVAL TO MINIMIZEDAMAGE TO TREE ROOTS. REPORT ANY CONFLICTS TOLANDSCAPE ARCHITECT.EXISTING TREE TO BE REMOVED INCLUDING ROOTS AND STUMP,LEGALLY DISPOSE OF OFF SITE.EXISTING LANDSCAPING TO BE REMOVED INCLUDING ROOTS ANDSTUMPS. REMOVE ANY AND ALL MULCH / ROCK. LEGALLY DISPOSEOF OFF SITE.CLEAN AND CLEAR AREA OF ALL TRASH, LANDSCAPE DEBRIS, ANDANY ADDITIONAL LANDSCAPING. LEGALLY DISPOSE OF OFF SITE.LIMIT GRADING WITHIN TREE PROTECTION FENCE AREA TO HANDDIGGING, TAKING CARE NOT TO DISTURB ROOTS.MITIGATE SOIL COMPACTION WITH 12" OF HARDWOOD MULCHBETWEEN TREE PROTECTION FENCE AND STRUCTURE.PROVIDE A DESIGNATED CONCRETE WASHOUT AREA IN ANAPPROVED LOCATION. PREVENT DISCHARGE OF WASHOUTMATERIALS TO STORM DRAINS OR ADJACENT AREAS. 24356789 20' ADJACENT USE SETBACK 40' ADJACENT STREET SETBACK 20' ADJACENT STREET SETBACK 40' ADJACENT STREET SETBACK 20' ADJACENT USE SETBACK SOUTHERN BOUNDARY (325 LF) - MARSHLAND ROADTYPE 'B' OPTION 1 (25') MINOR ARTERIAL BUFFER WESTERN BOUNDARY (139 LF) - LEG OF MUTTON ROADTYPE 'B' OPTION 1 (25') MINOR ARTERIAL BUFFER NORTHWESTERN BOUNDARY (282 LF) - SHARED INDUSTRIAL (IL ZONING) PROPERTYLINENO EXTERIOR BOUNDARY BUFFER REQUIRED NORTHERN BOUNDARY(90 LF) - TRELIS COURTTYPE 'A' OPTION 1 (20')ADJACENTSTREET BUFFER EASTERN BOUNDARY (235 LF) - SHARED INDUSTRIAL (IL ZONING) PROPERTY LINENO EXTERIOR BOUNDARY BUFFER REQUIRED EXISTINGVEGETATIONTO REMAIN, TYP. EXISTINGVEGETATIONTO REMAIN, TYP. G1.3TYPE G IMPERVIOUS INLET PROTECTION 1.1TYP.1.2TYP. 1.3TYP. 2.1TYP.2.2TYP.2.3TYP. 1TYP.3TYP. 4TYP. 5TYP.6TYP. 7TYP.8TYP. 9TYP. MOVEABLE DUMPSTER, TYP. NA Page 54 of 69 26 DBH LIVE OAK (SIGNIFICANT TREE) - PROPOSED CANOPY IMPACT: 33%5 9 10 11 13 16 17 DBH LIVE OAK (SPECIMEN TREE) - PROPOSED CANOPY IMPACT: 71%13 16 19 DBH LIVE OAK (SIGNIFICANT TREE) - PROPOSED CANOPY IMPACT:50%26 DBH LIVE OAK (SIGNIFICANT TREE) - PROPOSED CANOPY IMPACT: 80%15 22 DBH LIVE OAK (SIGNIFICANT TREE) - PROPOSED CANOPY IMPACT: 16% SPECIMEN AND SIGNIFICANT TREEENCROACHMENT SUMMARY: 24 DBH LIVE OAK (SIGNIFICANT TREE) - PROPOSED CANOPY IMPACT: 9%ABDCEFLAYOUT PLANL200 SITE DEVELOPMENT PLANSFORMEMORY MATTERSHILTON HEAD ISLAND, SOUTH CAROLINA DRAWING NUMBERDRAWING TITLE DESIGN CONCEPTS, DRAWING, SHEETS,LOGOS, SPECIFICATIONS, DETAILS,WRITTEN MATERIAL SHALL NOT BE USEDOR REPRODUCED IN WHOLE OR IN PARTIN ANY FORM WITHOUT PRIOR WRITTENCONSENT OF WJK LTD.© 2026 WJK LTD.THIS SHEET TO SCALE AT: 24"X36" DATE:PROJECT NO.:DRAWN BY:CHECKED BY:JUL 29, 202626056.01SDJC REVISIONS:DRB SUBMITTALPLAN, NOT FORCONSTRUCTION MEMORY MATTERSBUILDING LAGOON PROPERTY LINE PROPERTY LINEBIKE PATH EASEMENT PROPERTY LINE PROPERTY LINE PROPERTY LINE LOT 17 LOT 19TRELLIS COURT LEG OF MUTTON ROAD MARSHLAND ROAD cNEW02040608010305070Scale 1 " = 20' KEY SHEET REFERENCE NOTES:1PLANTING AREA, TYP., REFER TO PLANTING PLANSMAINTAIN EXISTING ENTRANCE ACCESS.MAINTAIN EXISTING PERMEABLE PAVER DRIVE, CONTRACTORRESPONSIBLE FOR REPLACEMENT / REPAIR OF ANY AND ALLDAMAGES.TIE PROPOSED WALK INTO EXISTING PARKING LOT EVENLY ANDSMOOTHLY.PROPOSED IMPROVEMENTS BY OTHERS, N.I.C., SHOWN FORREFERENCE ONLY. COORDINATE WITH ARCHITECT AS REQUIRED.A.D.A ACCESSIBLE PARKING PROVIDED NEAR RAMP ENTRANCE.243P.A. EXISTINGPAVE DRIVE EXISTINGSTORMPAVER DRIVE SITE HARDSCAPE LEGENDSYMB.DETAILDESCRIPTIONCALL-OUT2.2BRICK PAVERSTABBY CONCRETE2.35/L6002.1GRANITE FINES4/L600SITE DETAILS LEGENDDETAILDESCRIPTION9.1CALL-OUT7.2FENCE7/L6001/L6012/L6017.1GATEARBOR BORDERS, REFER TO DETAILS 3/L600,4/L600NANA 2.4 20' ADJACENT USE SETBACK 40' ADJACENT STREET SETBACK 20' ADJACENT STREET SETBACK 40' ADJACENT STREET SETBACK 20' ADJACENT USE SETBACK SOUTHERN BOUNDARY (325 LF) - MARSHLAND ROADTYPE 'B' OPTION 1 (25') MINOR ARTERIAL BUFFER WESTERN BOUNDARY (139 LF) - LEG OF MUTTON ROADTYPE 'B' OPTION 1 (25') MINOR ARTERIAL BUFFER NORTHWESTERN BOUNDARY (282 LF) - SHARED INDUSTRIAL (IL ZONING) PROPERTYLINENO EXTERIOR BOUNDARY BUFFER REQUIRED NORTHERN BOUNDARY(90 LF) - TRELIS COURTTYPE 'A' OPTION 1 (20')ADJACENTSTREET BUFFEREASTERN BOUNDARY (235 LF) - SHARED INDUSTRIAL (IL ZONING) PROPERTY LINENO EXTERIOR BOUNDARY BUFFER REQUIRED EXISTINGVEGETATIONTO REMAIN, TYP. EXISTINGVEGETATIONTO REMAIN, TYP. PROJECT INFORMATION:ZONINGZONING DISTRICT: LIGHT INDUSTRIAL (IL)OVERLAY DISTRICT: OCRM HIGH TIDE LINE (COR)USE OF PROPERTY: OTHER COMMERCIALSITEGROSS SITE ACREAGE: 2.39 ACNET SITE ACREAGE: 2.39 ACAREA OF DISTURBANCE: <0.5 ACDENSITYALLOWED TOTAL DENSITY: 23,900 GFA (10,000 GFA PER ACRE)EXISTING BUILDING SQUARE FOOTAGE: +/- 7,970PROPOSED BUILDING SQUARE FOOTAGE: +/- 8,635BUILDING HEIGHTMAXIMUM HEIGHT ALLOWED: 35'PROPOSED BUILDING HEIGHT: AS EXISTING <35'SITE IMPERVIOUSMAXIMUM ALLOWED IMPERVIOUS AREA: 67,546 SF (65% OF SITE)CURRENT IMPERVIOUS AREA: 52,132 SF (50% OF SITE)PROPOSED IMPERVIOUS AREA: 55,939 SF (54%)PARKINGMINIMUM NUMBER OF PARKING SPACES REQUIRED: 1 PER 350 GFAEXISTING NUMBER OF PARKING SPACES: 22PROPOSED NUMBER OF PARKING SPACES: 22FLOOD ZONE ZONE 'X-SHADED' SHOWN ON HHI FEMA 2021 MAP CONCRETE STAIRS GATE WITHELECTRONIC BY-PASS GATE WITHELECTRONIC BY-PASS GATE WITHELECTRONIC BY-PASS ENTRY SIGNAGEBY OWNERDONORPLAQUETBDEXISTING PLANTINGBED TO REMAIN 2.3TYP.2.1TYP. 2.2TYP.7.1TYP.7.2TYP.9.1TYP. SITE FURNITUREBY OWNERBENCHES WILL BEANCHORED TOCONCRETE PADS, TYP.ENGRAVEDPAVER WALKTBD ENGRAVEDFOUNDERS RINGTBDP.A. P.A.TYP.1 2TYP.3TYP.4TYP. 3/L600 6/L600 DUMPSTERENCLOSURESEE ARCHITECT'S PLANS GENERATOR, SEEARCHITECT'S PLANS 350 GAL. BURIEDPROPANE TANK 5 2.4TYP. FOOD DELIVERY PARKINGTO MATCH EXISTINGDRIVE A BDC EF5TYP. Page 55 of 69 GRADING PLANL300 SITE DEVELOPMENT PLANSFORMEMORY MATTERSHILTON HEAD ISLAND, SOUTH CAROLINA DRAWING NUMBERDRAWING TITLE DESIGN CONCEPTS, DRAWING, SHEETS,LOGOS, SPECIFICATIONS, DETAILS,WRITTEN MATERIAL SHALL NOT BE USEDOR REPRODUCED IN WHOLE OR IN PARTIN ANY FORM WITHOUT PRIOR WRITTENCONSENT OF WJK LTD.© 2026 WJK LTD.THIS SHEET TO SCALE AT: 24"X36" DATE:PROJECT NO.:DRAWN BY:CHECKED BY:JUL 29, 202626056.01SDJC REVISIONS:DRB SUBMITTALPLAN, NOT FORCONSTRUCTION GRADING ABBREVIATIONSDESCRIPTIONABBR.DESCRIPTIONFINISHED FLOORELEVATIONFFETOP OF DRAINRIMHIGH POINTHP LOW POINTLPBOTTOM OF STEPBSTOP OF STEPTSBOTTOM OF WALLBWTOP OF WALLTWABBR.BOTTOM OF CURBBCFINISHED GRADEFGTOP OF CURBTC GRADING LEGENDSYMB.DESCRIPTIONSPOT GRADEDRAINAGE ARROWPROPOSED CONTOUR MAJORPROPOSED CONTOUR MINOREXISTING GRADE GRADING REFERENCE NOTES:1MINIMIZE DISTURBANCE AROUND TREES TO REMAIN.PITCH TO DRAIN INLET AT 1% MIN., 2% MAX.PROVIDE 2% MAX. SLOPE IN ALL DIRECTIONS.A.D.A. RAMP AT 1:12 MAX.CONTRACTOR SHALL TIE GUTTER DOWNSPOUTS INTOSUBSURFACE DRAINAGE SYSTEM WHENEVER POSSIBLE.TIE INTO EXISTING GRADE. MEET SMOOTHLY AND EVENLY.MAINTAIN EXISTING DRAINAGE PATTERN AWAY FROM BUILDING.DIRECT STORMWATER TOWARDS STREET OR EXISTING DRAINAGEDITCH, DRAINAGE SHALL NOT BE DIRECTED TOWARDS ADJACENTPROPERTY. CONTRACTOR SHALL PROVIDE SUPPLEMENTALAREA DRAINS, FRENCH DRAINS, AND DRY WELLS AS REQUIREDTO PROMOTE PROPER STORMWATER DRAINAGE, REFER TODETAILS. 2435678 MEMORY MATTERSBUILDING LAGOON PROPERTY LINE PROPERTY LINEBIKE PATH EASEMENT PROPERTY LINE PROPERTY LINE PROPERTY LINE LOT 17 LOT 19TRELLIS COURT LEG OF MUTTON ROAD MARSHLAND ROAD cNEW02040608010305070Scale 1 " = 20' 20' ADJACENT USE SETBACK 40' ADJACENT STREET SETBACK 20' ADJACENT STREET SETBACK 40' ADJACENT STREET SETBACK 20' ADJACENT USE SETBACK SOUTHERN BOUNDARY (325 LF) - MARSHLAND ROADTYPE 'B' OPTION 1 (25') MINOR ARTERIAL BUFFER WESTERN BOUNDARY (139 LF) - LEG OF MUTTON ROADTYPE 'B' OPTION 1 (25') MINOR ARTERIAL BUFFER NORTHWESTERN BOUNDARY (282 LF) - SHARED INDUSTRIAL (IL ZONING) PROPERTYLINENO EXTERIOR BOUNDARY BUFFER REQUIRED NORTHERN BOUNDARY(90 LF) - TRELIS COURTTYPE 'A' OPTION 1 (20')ADJACENTSTREET BUFFEREASTERN BOUNDARY (235 LF) - SHARED INDUSTRIAL (IL ZONING) PROPERTY LINENO EXTERIOR BOUNDARY BUFFER REQUIRED EXISTINGVEGETATIONTO REMAIN, TYP. EXISTINGVEGETATIONTO REMAIN, TYP. 11.912.212.214.313.513.513.314.314.314.214.112.712.6TC 13.113.313.012.7 11.911.912.011.012.012.412.4512.5 12.412.512.714.31213 12 12141413 1TYP. 122TYP. 3TYP.4TYP. 5TYP. 6TYP.7TYP. 8TYP. Page 56 of 69 UTILITY PLANL400 SITE DEVELOPMENT PLANSFORMEMORY MATTERSHILTON HEAD ISLAND, SOUTH CAROLINA DRAWING NUMBERDRAWING TITLE DESIGN CONCEPTS, DRAWING, SHEETS,LOGOS, SPECIFICATIONS, DETAILS,WRITTEN MATERIAL SHALL NOT BE USEDOR REPRODUCED IN WHOLE OR IN PARTIN ANY FORM WITHOUT PRIOR WRITTENCONSENT OF WJK LTD.© 2026 WJK LTD.THIS SHEET TO SCALE AT: 24"X36" DATE:PROJECT NO.:DRAWN BY:CHECKED BY:JUL 29, 202626056.01SDJC REVISIONS:DRB SUBMITTALPLAN, NOT FORCONSTRUCTION MEMORY MATTERSBUILDING LAGOON PROPERTY LINE PROPERTY LINEBIKE PATH EASEMENT PROPERTY LINE PROPERTY LINE PROPERTY LINE LOT 17 LOT 19TRELLIS COURT LEG OF MUTTON ROAD MARSHLAND ROAD cNEW02040608010305070Scale 1 " = 20' SODSOD 20' ADJACENT USE SETBACK 40' ADJACENT STREET SETBACK 20' ADJACENT STREET SETBACK 40' ADJACENT STREET SETBACK 20' ADJACENT USE SETBACK SOUTHERN BOUNDARY (325 LF) - MARSHLAND ROADTYPE 'B' OPTION 1 (25') MINOR ARTERIAL BUFFER WESTERN BOUNDARY (139 LF) - LEG OF MUTTON ROADTYPE 'B' OPTION 1 (25') MINOR ARTERIAL BUFFER NORTHWESTERN BOUNDARY (282 LF) - SHARED INDUSTRIAL (IL ZONING) PROPERTYLINENO EXTERIOR BOUNDARY BUFFER REQUIRED NORTHERN BOUNDARY(90 LF) - TRELIS COURTTYPE 'A' OPTION 1 (20')ADJACENTSTREET BUFFEREASTERN BOUNDARY (235 LF) - SHARED INDUSTRIAL (IL ZONING) PROPERTY LINENO EXTERIOR BOUNDARY BUFFER REQUIRED LIGHTING SCHEDULESYMB.DETAIL3/L60110.1CALL-OUT4/L6015/L6011/L60210.210.310.4DESCRIPTIONPATH LIGHTQTY.37223UP LIGHTSTEP LIGHT5POST LIGHTLIGHTING / UTILITY REFERENCE NOTES:1243SPACE LIGHTS EQUALLY AS SHOWN.ADJUST LAMP ORIENTATION IN FIELD PER LANDSCAPEARCHITECTS INSTRUCTION.4" P.V.C. SLEEVE FOR ELECTRICAL CONDUIT AND WIRING. PLACE AMINIMUM OF 12" UNDER BOTTOM OF PAVING SURFACE.LIGHTING CONTROL SYSTEM TO BE COORDINATED WITHARCHITECTS BUILDING CONTROL SYSTEMS. TIMER BASED WITHMANUAL OVERRIDE FOR SPECIAL EVENTS.NOTE: PARKING LOT LIGHTING TO REMAIN. 10.1TYP.10.2TYP. 10.3TYP. 10.4TYP.1TYP.2TYP. 3TYP. 4TYP. 5 Page 57 of 69 PLANTING PLANL500 SITE DEVELOPMENT PLANSFORMEMORY MATTERSHILTON HEAD ISLAND, SOUTH CAROLINA DRAWING NUMBERDRAWING TITLE DESIGN CONCEPTS, DRAWING, SHEETS,LOGOS, SPECIFICATIONS, DETAILS,WRITTEN MATERIAL SHALL NOT BE USEDOR REPRODUCED IN WHOLE OR IN PARTIN ANY FORM WITHOUT PRIOR WRITTENCONSENT OF WJK LTD.© 2026 WJK LTD.THIS SHEET TO SCALE AT: 24"X36" DATE:PROJECT NO.:DRAWN BY:CHECKED BY:JUL 29, 202626056.01SDJC REVISIONS:DRB SUBMITTALPLAN, NOT FORCONSTRUCTION PLANT KEY LEGENDPLANTING DETAILSDETAILDESCRIPTIONTREE PLANTING14.1CALL-OUT14.214.3PALM TREE PLANTINGSHRUB PLANTING14.4GROUND COVER PLANTING1/L5012/L5013/L5014/L501 PLANTING REFERENCE NOTES:1EXISTING VEGETATION TO REMAIN.EXISTING TREES TO REMAIN.EXISTING TREES TO BE REMOVED.UNDISTURBED BUFFER.CAREFULLY EXCAVATE SHRUB PITS IN VICINITY OF EXISTING TREES,WITHOUT DISTURBING TREE ROOTS.COORDINATE SHRUB LAYOUT WITH EXISTING UTILITIES. REPORTANY CONFLICTS TO LANDSCAPE ARCHITECT.24356 MEMORY MATTERSBUILDING LAGOON PROPERTY LINE PROPERTY LINEBIKE PATH EASEMENT PROPERTY LINE PROPERTY LINE PROPERTY LINE LOT 17 LOT 19TRELLIS COURT LEG OF MUTTON ROAD MARSHLAND ROAD cNEW02040608010305070Scale 1 " = 20' 1 QUEV 3 HYLL 6 SERR 2 CHAH10 PLUA1 CAMS9 LOPD SODSOD3 ILLP15 LIRE1 QUEV5 LANC1 SABP5 ILEN4 HYDE9 PODM20 OPHJ 1 QUEV8 VIBS19 PODM3 OSMF15 FARG 20' ADJACENT USE SETBACK 40' ADJACENT STREET SETBACK 20' ADJACENT STREET SETBACK 40' ADJACENT STREET SETBACK 20' ADJACENT USE SETBACK SOUTHERN BOUNDARY (325 LF) - MARSHLAND ROADTYPE 'B' OPTION 1 (25') MINOR ARTERIAL BUFFER WESTERN BOUNDARY (139 LF) - LEG OF MUTTON ROADTYPE 'B' OPTION 1 (25') MINOR ARTERIAL BUFFER NORTHWESTERN BOUNDARY (282 LF) - SHARED INDUSTRIAL (IL ZONING) PROPERTYLINENO EXTERIOR BOUNDARY BUFFER REQUIRED NORTHERN BOUNDARY(90 LF) - TRELIS COURTTYPE 'A' OPTION 1 (20')ADJACENTSTREET BUFFEREASTERN BOUNDARY (235 LF) - SHARED INDUSTRIAL (IL ZONING) PROPERTY LINENO EXTERIOR BOUNDARY BUFFER REQUIRED EXISTINGVEGETATIONTO REMAIN, TYP. EXISTINGVEGETATIONTO REMAIN, TYP. 1 QUEV 3 SERR 3 SERR7 ILEV5 ILLP3 ILLP3 ILEN1 ILEV3 ILEN3 ILLP3 AZAE3 AZAE1 MAGV3 AZAE3 ILLP2 VIBS3 ILLP3 HYDE 3 ILEV5 LANC3 AZAE3 ILEN5 PLUA5 PLUA2 ILEN3 AZAE7 AZAE3 ILEN5 PODM6 AZAE3 SERR 1 SABP5 LANC13 PODM3 ILEN4 PODM3 LOPD 10 LANC 10 FARJ 11 ILEN10 LIRE3 SERR1 MAGV3 AZAE3 HYLL10 LIRE 6 ILEN9 LOPD 3 HYLL10 LIRE1 OSMF15 FARJ1 CAMS3 HYLL10 PODM 3 LAGN10 FARG 10 LANC3 CAMS3 SERR2 AZAE6 ILEN 14.1TYP. 14.2TYP. 14.3TYP. 14.4TYP. 12 3TYP. 5TYP. 6 2 TRAJ20 LANC 2 CAMS 5 FARJ 1 MAGV 20 LANC6 ILLP Page 58 of 69 PLANT SCHEDULE ANDDETAILSL501 SITE DEVELOPMENT PLANSFORMEMORY MATTERSHILTON HEAD ISLAND, SOUTH CAROLINA DRAWING NUMBERDRAWING TITLE DESIGN CONCEPTS, DRAWING, SHEETS,LOGOS, SPECIFICATIONS, DETAILS,WRITTEN MATERIAL SHALL NOT BE USEDOR REPRODUCED IN WHOLE OR IN PARTIN ANY FORM WITHOUT PRIOR WRITTENCONSENT OF WJK LTD.© 2026 WJK LTD.THIS SHEET TO SCALE AT: 24"X36" DATE:PROJECT NO.:DRAWN BY:CHECKED BY:JUL 29, 202626056.01SDJC REVISIONS:DRB SUBMITTALPLAN, NOT FORCONSTRUCTION 1L501TREE PLANTINGSCALE: N.T.S.2L501PALM TREE PLANTINGSCALE: N.T.S. 3L501SHRUB PLANTINGSCALE: N.T.S.4L501GROUND COVER PLANTINGSCALE: N.T.S.5L501TREE STAKINGSCALE: N.T.S. PLANT SCHEDULE: PLANT TABLE: BLACK RUBBER HOSE120°120°120°PLANDOUBLE STRAND 12 GAUGEWIREPROTECT TREE TRUNK WITH BLACK RUBBERHOSE OR APPROVED EQUALDOUBLE STRAND 12 GAUGE WIRE WITHGALVANIZED TURNBUCKLE OR APPROVEDEQUAL. MARK AS HAZARD IN LOCATIONWITH HIGH PEDESTRIAN TRAFFIC3" MINIMUM MULCH DEPTH, REFER TO PLANTSCHEDULE FOR TYPESOIL BERM TO HOLD WATERTREE 2"X4" STAKES (36" LONG) BURIED BELOWFINISH GRADE - ENSURE STAKES ARE MARKEDTO SIGNIFY HAZARD IN LOCATIONS WITHHIGH PEDESTRIAN TRAFFICFINISH GRADEB&B OR CONTAINERIZED (REFER TO PLANTSCHEDULE)SCARIFY SIDES OF HOLE TO 4" DEPTH MINIMUMAMENDED PLANTING SOIL AS NEEDED PERSOIL ANALYSISCOMPACT PLANTING SOIL BENEATHROOTBALLNOTES:1.TREE STAKING OPTIONAL, HOWEVER, LANDSCAPE CONTRACTOR RESPONSIBLE FOR MAINTAINING TREES IN AN UPRIGHT (90 DEGREE/PERPENDICULAR) POSITION FOR 1 YEAR AFTER PLANTING IS COMPLETE OR UNTIL TREE ROOT SYSTEM IS FULLY ESTABLISHED AND STURDY.FINAL TREE STAKING DETAILS AND PLACEMENT TO BE APPROVED BY OWNER'S REPRESENTATIVE.2.CONTRACTOR SHALL ASSURE PERCOLATION OF ALL PLANTING PITS PRIOR TO INSTALLATION.3.IN SEMI-IMPERVIOUS SOIL CONDITIONS, ROOTBALL ELEVATION SHALL BE 2" ABOVE FINISH GRADE. COORDINATE WITH OWNER'SREPRESENTATIVE PRIOR TO SETTING ROOTBALL ELEVATIONS. 12" TYP. 12"MIN. DOUBLE SIZE OFROOTBALL, TYP. CLEAR TRUNK,REFER TO PLANTSCHEDULE COMPACTED SUBGRADE AMENDED PLANTING SOIL ASNEEDED PER SOIL ANALYSIS3" MINIMUM MULCH DEPTH,REFER TO PLANT SCHEDULE FORTYPEFINISH GRADESOIL BERM TO HOLD WATERMAINTAIN TREE IN A PLUMBUPRIGHT POSITION TRUNK OF PALMETTOS SHALL BENEARLY UNIFORM IN SIZE OVERENTIRE HEIGHT AND SHALL BEFREE OF OLD FROND STUBS, FIREBLACK AND OTHER DAMAGE REFOLIATED PALMETTO NOTES:1.FINAL TREE STAKING DETAILS AND PLACEMENT TO BE APPROVED BY OWNER OR OWNER'S REPRESENTATIVE,2.CONTRACTOR SHALL ASSURE PERCOLATION OF ALL PLANTING PITS PRIOR TO INSTALLATION.3.SABAL PALMETTOS SHALL BE REFOLIATED, PROTECT CABBAGE HEAD FROM DAMAGE. NOTES:1.WHEN GROUNDCOVERS AND SHRUBS ARE USED IS MASSES, ENTIRE BED TO BE EXCAVATED TO RECEIVE PLANTING SOIL ANDPLANT MATERIAL.2.CONTRACTOR SHALL ASSURE PERCOLATION OF ALL PLANTING PITS PRIOR TO INSTALLATION.3.IN SEMI-IMPERVIOUS SOIL CONDITIONS, ROOTBALL ELEVATION SHALL BE ±2" ABOVE FINISH GRADE. COORDINATE WITHOWNER'S REPRESENTATIVE PRIOR TO SETTING ROOTBALL ELEVATIONS. 4" TYP.DOUBLE SIZE OFROOTBALL, TYP.AMENDED PLANTING SOIL ASNEEDED PER SOIL ANALYSISB&B OR CONTAINERIZED (SEEPLANTING SCHEDULE, THIS SHEET)FINISH GRADESOIL BERM TO HOLD WATER3" MINIMUM MULCH DEPTH,REFER TO PLANT SCHEDULE FORTYPE --- SPECIFIED O.C. SPACINGNOTE:1.EXCAVATE ENTIRE BED SPECIFIED FORGROUNDCOVER PLANTING TO A DEPTHOF 12"TYPICAL EDGE OFPLANT BED1/2 OF SPECIFIED O.C.SPACINGSPECIFIED O.C.SPACINGATYPICAL SPACING INCURVILINEAR PLANT BEDS.OUTSIDE ROW TO FOLLOWCURVE AS SHOWN ON PLAN ±5' DIA.3" MINIMUM MULCH DEPTH, REFERTO PLANT SCHEDULE FOR TYPESMOOTH CONTINUOUSLY CUT EDGETYPICAL TREETREE STAKE NOTES:1.APPLY MULCH IN A ±5' DIAMETER WHEREPROPOSED TREE PLANTINGS OCCUR IN SODOR SEEDED AREAS. CAT. I AND CAT. II TREE MITIGATION SATISFIED BY PLANTINGOF 4 LIVE OAKS (QUEV)SEE PLANT SCHEDULE -CAT. III MITIGATION SATISFIED BY PLANTING OF 13 ILEV, 3MAGV, AND 2 SABP.SEE PLANT SCHEDULE -NOTE:*** ******* Page 59 of 69 SITE DEVELOPMENT PLANSFORMEMORY MATTERSHILTON HEAD ISLAND, SOUTH CAROLINA DRAWING NUMBERDRAWING TITLE DESIGN CONCEPTS, DRAWING, SHEETS,LOGOS, SPECIFICATIONS, DETAILS,WRITTEN MATERIAL SHALL NOT BE USEDOR REPRODUCED IN WHOLE OR IN PARTIN ANY FORM WITHOUT PRIOR WRITTENCONSENT OF WJK LTD.© 2026 WJK LTD.THIS SHEET TO SCALE AT: 24"X36" DATE:PROJECT NO.:DRAWN BY:CHECKED BY:JUL 29, 202626056.01SDJC REVISIONS:DRB SUBMITTALPLAN, NOT FORCONSTRUCTION L600SITE DETAILS - 01 1L600TREE PROTECTION FENCESCALE: 1" - 1'-0"2L600SILT FENCESCALE: 1" - 1'-0" 3L600BRICK PAVERSSCALE: 1" - 1'-0"4L600TABBY CONCRETESCALE: 1" - 1'-0"5L600GRANITE FINESSCALE: 1" - 1'-0" 6L600CONCRETE STAIRSSCALE: 1" - 1'-0"7L600GATESCALE: 3/4" - 1'-0" SECTION4", TYP.1012" 3'-3"7"11"6'-8' O.C., FIELD ADJUSTTO PROTECT TREE412" SLOTS3'-10"2'6" RADIUS = 12 X D.B.H. OR5', WHICHEVER IS GREATER3"X6" CEDAR SPLITRAIL UPRIGHTS,NATURAL FINISH2"X4" CEDAR SPLITRAILS WITHTAPERED TIPS TOMEET SLOTS,NATURAL FINISHCOMPACTEDAGGREGATE BASEEXISTING SUBGTADE WARNING SIGN24"x24" MIN.TREE PROTECTION ZONEDOT NOT ENTERZONA DE PROTECCIONDE ARBOLESNO ENTRAR ALTERNATIVE FENCING:BRIGHT ORANGE PLASTIC MESH - 48" HT. WITH REQUIRED SIGNAGE. PER TOWN OF HILTON HEAD LMO SEC. 16-6-104.3 MAXIMUM SPACING = 6 FT.FILTER FABRICBACKFILL TRENCH WITHCOMPACTED EARTHCOMPACTEDEARTHFILTER FABRIC6-IN.24-IN.(MINIMUM) 24-IN.(MINIMUM)6-IN. RUNOFFRUNOFF RUNOFF 18-IN. TO 24-IN. BURY FABRICUSE EITHER FLAT-BOTTOMOR V-BOTTOM TRENCHSEE DETAILS FLAT-BOTTOM TRENCH DETAIL V-SHAPED TRENCH DETAIL SILT FENCE INSTALLATION FILTERFABRIC BURY FILTER FABRICAT LEAST 12-INCHES 1.25 LB./LINEAR FT. STEEL POSTSHEAVY DUTYPLASTIC TIEFOR STEEL POSTS(RESTRICT TO TOP8-INCHES OFFABRIC)18-IN. TO 24-IN.SILT FENCE - GENERAL NOTES1.Do not place silt fence across channels or in other areas subject to concentrated flows. Silt fenceshould not be used as a velocity control BMP. Concentrated flows are any flows greater than 0.5 cfs.2.Maximum sheet or overland flow path length to the silt fence shall be 100-feet.3.Maximum slope steepness (normal [perpendicular] to the fence line) shall be 2:1.4. Silt fence joints, when necessary, shall be completed by one of the following options:-Wrap each fabric together at a support post with both ends fastened to the post, with a 1-foot minimum overlap;-Overlap silt fence by installing 3-feet passed the support post to which the new silt fence roll is attached. Attach old roll to new roll with heavy-duty plastic ties; or,-Overlap entire width of each silt fence roll from one support post to the next support post.5. Attach filter fabric to the steel posts using heavy-duty plastic ties that are evenly spaced within thetop 8-inches of the fabric.6.Install the silt fence perpendicular to the direction of the stormwater flow and place the silt fencethe proper distance from the toe of steep slopes to provide sediment storage and access formaintenance and cleanout.7.Install Silt Fence Checks (Tie-Backs) every 50-100 feet, dependent on slope, along silt fence that isinstalled with slope and where concentrated flows are expected or are documented along theproposed/installed silt fence. HEAVY DUTY PLASTIC TIESSILT FENCE - POST REQUIREMENTS1.Silt Fence posts must be 48-inch long steel posts that meet, at a minimum, thefollowing physical characteristics.-Composed of a high strength steel with a minimum yield strength of 50,000 psi.-Include a standard "T" section with a nominal face width of 1.38-inches and anominal "T" length of 1.48-inches.-Weigh 1.25 pounds per foot (± 8%)2.Posts shall be equipped with projections to aid in fastening of filter fabric.3. Steel posts may need to have a metal soil stabilization plate welded near thebottom when installed along steep slopes or installed in loose soils. The plate shouldhave a minimum cross section of 17-square inches and be composed of 15 gaugesteel, at a minimum. The metal soil stabilization plate should be completely buried.4.Install posts to a minimum of 24-inches. A minimum height of 1- to 2- inchesabove the fabric shall be maintained, and a maximum height of 3 feet shall bemaintained above the ground.5.Post spacing shall be at a maximum of 6-feet on center.SILT FENCE - FABRIC REQUIREMENTS1.Silt fence must be composed of woven geotextile filter fabric that consists ofthe following requirements:-Composed of fibers consisting of long chain synthetic polymers of at least 85% byweight of polyolefins, polyesters, or polyamides that are formed into a networksuch that the filaments or yarns retain dimensional stability relative to each other;-Free of any treatment or coating which might adversely alter its physicalproperties after installation;-Free of any defects or flaws that significantly affect its physical and/or filteringproperties; and,-Have a minimum width of 36-inches.2.Use only fabric appearing on SC DOT's Qualified Products Listing (QPL),Approval Sheet #34, meeting the requirements of the most current edition of theSC DOT Standard Specifications for Highway Construction.3. 12-inches of the fabric should be placed within excavated trench and toed inwhen the trench is backfilled.4.Filter Fabric shall be purchased in continuous rolls and cut to the length ofthe barrier to avoid joints.5.Filter Fabric shall be installed at a minimum of 24-inches above the ground. 1.The key to functional silt fence is weekly inspections, routine maintenance, andregular sediment removal.2.Regular inspections of silt fence shall be conducted once every calendar weekand, as recommended, within 24-hours after each rainfall even that produces1/2-inch or more of precipitation.3.Attention to sediment accumulations along the silt fence is extremely important.Accumulated sediment should be continually monitored and removed whennecessary.4.Remove accumulated sediment when it reaches 1/3 the height of the siltfence.5. Removed sediment shall be placed in stockpile storage areas or spread thinlyacross disturbed area. Stabilize the removed sediment after it is relocated.6.Check for areas where stormwater runoff has eroded a channel beneath thesilt fence, or where the fence has sagged or collapsed due to runoffovertopping the silt fence. Install checks/tie-backs and/or reinstall silt fence,as necessary.7.Check for tears within the silt fence, areas where silt fence has begun todecompose, and for any other circumstance that may render the silt fenceineffective. Removed damaged silt fence and reinstall new silt fenceimmediately.8.Silt fence should be removed within 30 days after final stabilization is achievedand once it is removed, the resulting disturbed area shall be permanentlystabilized. SILT FENCE - INSPECTION & MAINTENANCE COMPACTEDEARTHFILTER FABRICHEAVY DUTY PLASTIC TIES6-IN. HAND TIGHT / BUTTJOINTED WITH SANDSWEPT JOINTSNOTES:1.PROVIDE 1% MIN., 2% MAX. CROSS SLOPEON ALL PAVED SURFACES FOR POSITIVEDRAINAGE.2.REFER TO PLAN (SHEET L200) FORWIDTHS OF WALKS AND LOCATION OFBRICK BORDERS.3.CONTRACTOR SHALL COORDINATEBORDERS AND PATTERN WITH OWNER'SREPRESENTATIVE PRIOR TOCONSTRUCTION.4.UPON REQUEST, CONTRACTOR SHALLPROVIDE 4'X4' PAVING PANELS OFALTERNATIVE COLORS PRIOR TOCONSTRUCTION FOR APPROVAL BYOWNER OR LANDSCAPE ARCHITECT. BRICK MANUFACTURER INFORMATION:MANUFACTURER: TO MATCHARCHITECTUREBRICK: TO MATCH ARCHITECTURECOLOR: TO MATCH ARCHITECTUREPATTERN: HERRINGBONE FIELD (REFERTO PLAN, SHEET L100, FOR DIRECTION)WITH SINGLE HEADER COURSE BORDERJOINTS: HAND TIGHT / BUTT JOINTED,SAND SWEPT 4"5"8" BRICK FIELD, TYP.BRICK BORDER, TYP.SAND SETTING BED PERMANUFACTURER'SSPECIFICATIONSCONCRETE BASECOMPACTEDAGGREGATE BASE COMPACTED SUBGRADEEXISTING SUBGRADE6" MORTAR, TYP. BRICK FIELD, TYP.BRICK BORDER, TYP.HAND TIGHT / BUTTJOINTED WITH SANDSWEPT JOINTS45° CUT ATINTERSECTIONS, TYP., CUTALL BRICK FROM FULL,TYP.ADJACENT MATERIALVARIES, REFER TO PLANSPLAN SECTION A-A' AA'OTHER INFORMATION:CONCRETE: 3,000 P.S.I. AT 28 DAYSSOIL COMPACTION: 95% STANDARDPROCTORFINISHED GRADE4"6"NOTES:1.PROVIDE 1% MIN., 2% MAX. CROSS SLOPEON ALL PAVED SURFACES FOR POSITIVEDRAINAGE.2.REFER TO PLAN (SHEET L200) FORWIDTHS OF WALK.3.CONSTRUCT EXPANSION JOINTS WHEREWALK MEETS CURBS, STEPS, WALLS ORFIXED SLABS.4.UPON REQUEST, CONTRACTOR SHALLPROVIDE 4'X4' SAMPLE OF CONCRETEWITH 2 SIZES OF OYSTER SHELL FINISHFOR APPROVAL BY OWNER ORLANDSCAPE ARCHITECT. TABBY SPEC:1.SHELL FINISH SHALL BE OYSTER SHELL MIX(EQUAL PARTS, SIZE #2, AND #3) HANDTHROWN / SPREAD TO 100% COVERAGEON FRESH POURED AND LEVELEDCONCRETE.2.HAND FLOAT UNTIL SHELL ISSUBMERGED, THEN AFTER 90% CURED,LIGHTLY PRESSURE WASH UNTIL SHELL ISEXPOSED. SECTION A-A'12"TABBY CONCRETE WALKWITH TURNDOWNSAND 6X6 10-10 W.W.M.FINISHED GRADECOMPACTEDSUBGRADEEXISTING SUBGRADEBRICK BORDER, TYP.MORTAR SETTING BEDPER MANUFACTURERSSPEC., TYP. BRICK MANUFACTURER INFORMATION:MANUFACTURER: TO MATCHARCHITECTUREBRICK: TO MATCH ARCHITECTURECOLOR: TO MATCH ARCHITECTUREPATTERN: SINGLE HEADER COURSE BORDERJOINTS: TO MATCH ARCHITECTUREPLAN TABBY CONCRETEWALKEXPANSION JOINTCONTROL JOINTA A'WIDTH VARIES, REFER TOPLAN, SHEET L200 BRICK BORDER, TYP.MORTAR JOINTS, TYP. CONCRETE INFORMATION:CONCRETE: 3,000 P.S.I. AT 28 DAYSFINISH: TABBY SHELL SOIL INFORMATION:SOIL COMPACTION: 95% STANDARDPROCTOR4" 45° CUT ATINTERSECTIONS, TYP., CUTALL BRICK FROM FULL,TYP.± 5"PLANSECTION A-A' STEEL STAKEFINISHEDGRADE± 4" COMPACTED CRUSHEDAGGREGATE BASEGEOTEXTILE FABRIC± 1" SPRING MIX GRAVEL TOPCOATCOMPACTED SUBGRADEEXISTING SUBGRADE SPRING MIX GRAVELADJACENT MATERIALVARIES, REFER TO PLANS(SHEET L200)STEEL EDGINGAA'EDGING AND STAKE INFORMATION:MANUFACTURER:BORDER CONCEPTS, INC.7621 LITTLE AVE., SUITE 426CHARLOTTE, NC. 28226PHONE: (800) 845.3343WEB: WWW.BORDER CONCEPTS.COMSTEEL EDGE: BORDER GUARD 3/16" X 4" X 16'STAKES: :STANDARD STAKE 3/16" THICK X 15"LONG (6 PER 16')COLOR: BLACKNOTE: INSTALL FLUSH PER MANUFACTURESSPECIFICATIONSOTHER INFORMATION:GEOTEXTILE FABRIC: TYPAR 3401 ORAPPROVED EQUALSOIL COMPACTION: 95% STANDARDPROCTOR4"STEEL EDGING 4" NON-SLIP SKIDGUARDS AS REQUIRED1'-2"7"R12" 10"12" EXPANSION JOINT, TYP. COMPACTEDAGGREGATE BASECOMPACTEDSUBGRADEEXISTING SUBGRADE CONCRETE STEPS ANDFOOTING, TYP. "L" BAR IN NOSE,CONTINUOUS, TYP."H" BAR, TYP."V" BAR, NO SPLICESHALL BE MADE, TYP.12" LONG METALDOWEL, TYP."L" BAR,CONTINUOUS, TYP. TABBYCONCRETEWALK, REFERTO DETAILX/LXEXPANSIONJOINT, TYP.REFER TODETAIL X/LXTABBY CONCRETE WALK,REFER TO DETAIL 4/L600NOTES:1.PROVIDE MIN. 1%, MAX. 2%CROSS SLOPE ON ALL PAVEDSURFACES FOR POSITIVEDRAINAGE.2.REFER TO PLAN FOR WIDTHS OFWALK.3.CONSTRUCT EXPANSION JOINTSWHERE WALK MEETS CURBS,STEPS, WALLS OR FIXED SLABS.4.UPON REQUEST, CONTRACTORSHALL PROVIDE 4'X4' SAMPLE OFCONCRETE WITH 2 SIZES OFOYSTER SHELL FINISH FORAPPROVAL BY OWNER ORLANDSCAPE ARCHITECT. CONCRETE INFORMATION:CONCRETE: 3,000 P.S.I. AT 28 DAYSFINISH: LIGHT BROOM FINISH WITHGRIT SEALER (STEPS TO HAVE NONSLIP SURFACE)SOIL INFORMATION:SOIL COMPACTION: 95% STANDARDPROCTORREBAR SCHEDULEREBARSIZESPACING"H" BAR"V" BAR#4#412" O.C.12" O.C.6"4""L" BAR#412" O.C.METALDOWEL#424" O.C. TYP. SECTION A-ANOTES:1.FENCE / GATE POSTS MOUNTING TO BECONFIRMED PER MANUFACTURERS SPEC. TO POOLDECK AND CONCRETE WALK. REFER TO PLANSHEET L200 FOR LOCATION.2.INSTALLATION TO BE COMPLETED PERMANUFACTURERS SPECIFICATIONS.3.CONTRACTOR SHALL CONFIRM GATE OPENINGAND HINGE ATTACHMENTS TO WOOD POSTSPRIOR TO CONSTRUCTION. REPORT ANYDISCREPANCIES TO OWNER , OWNER'SREPRESENTATIVE OF LANDSCAPE ARCHITECT.4.CONTRACTOR SHALL PROVIDE COLOR SAMPLESPRIOR TO CONSTRUCTION FOR APPROVAL BYOWNER OR LANDSCAPE ARCHITECT. LATCH, HINGE AND CANE BOLT INFORMATION:LATCH:SELF-LOCKING / QUICK RELEASEOR ACCESSED CONTROLLEDHINGE: SELF-CLOSINGCANE BOLT: TO BE COORDINATED WITHACCESS CONTROLLED LATCHOWNER TO APPROVE LATCH AND HINGEATTACHMENTS PRIOR TO ORDERING.FINISHED GRADE 6X6 WOOD POST1" SQUARE ALUMINUMFRAME, TYP.1" SQUAREALUMINUM RAIL, TYP.HINGE, TYP.FENCE5/8" SQUAREALUMINUM PICKET,TYP.4'-4"4'MIN.REFER TO NOTE 1FOR ATTACHMENTFINISHED GRADEALUMINUM GATE,REFER TO ELEVATIONAND MANUFACTURERSINFORMATION6X6 WOOD POST,SEE DETAIL 1/L602 72" WIDTH ELEVATIONA A LATCH, TYP.6X6 WOOD POST, TYP.CANE BOLT, REFER TO ELEVATION 4'MIN.4'-4"6'2'-1012"112" 3" 6'-5" O.C.72" WIDTH PLANINTERIOR SIDEEXTERIOR SIDEALUMINUM GATE CANE BOLT, TYP. SELF-LATCHINGLATCH, TYP.HINGE, TYP.312" MAX. GATE MANUFACTURER INFORMATION:MANUFACTURER:JERITH MANUFACTURING LLC14400 MCNULTY RD,PHILADELPHIA, PA, 19154PHONE: (800) 344.2242WEB: WWW.JERITH.COMGATE: LIBERTY STANDARD GATE 202 - 48"HEIGHTMATERIAL: ALUMINUMFENCE:POWDER COATED BLACKPOSTS:6X6 PRESSURE TREATED PINEMATERIAL: WOODCOLOR:MATCH STUCCO ACCENT OFBUILIDNG Page 60 of 69 SITE DEVELOPMENT PLANSFORMEMORY MATTERSHILTON HEAD ISLAND, SOUTH CAROLINA DRAWING NUMBERDRAWING TITLE DESIGN CONCEPTS, DRAWING, SHEETS,LOGOS, SPECIFICATIONS, DETAILS,WRITTEN MATERIAL SHALL NOT BE USEDOR REPRODUCED IN WHOLE OR IN PARTIN ANY FORM WITHOUT PRIOR WRITTENCONSENT OF WJK LTD.© 2026 WJK LTD.THIS SHEET TO SCALE AT: 24"X36" DATE:PROJECT NO.:DRAWN BY:CHECKED BY:JUL 29, 202626056.01SDJC REVISIONS:DRB SUBMITTALPLAN, NOT FORCONSTRUCTION L601SITE DETAILS - 02 1L601FENCESCALE: 3/4" - 1'-0"2L601ARBORSCALE: 1/2" - 1'-0" FENCE MANUFACTURER INFORMATION:MANUFACTURER:JERITH MANUFACTURING LLC14400 MCNULTY RD,PHILADELPHIA, PA, 19154PHONE: (800) 344.2242WEB: WWW.JERITH.COMFENCE: RESIDENTIAL FENCE STYLE 202 - 48" HEIGHTMATERIAL: ALUMINUMCOLOR: POWDER COATED BLACKPOSTS: 4X4 PRESSURE TREATED PINEMATERIAL: WOODCOLOR: MATCH STUCCO ACCENT OF BUILDING NOTES:1.INSTALLATION TO BE COMPLETEDPER MANUFACTURERSSPECIFICATIONS2.CONTRACTOR TO VERIFY ALLDIMENSIONS PRIOR TOCONSTRUCTION. REPORT ANYDISCREPANCIES TO OWNER,OWNER'S REPRESENTATIVE ORLANDSCAPE ARCHITECT.3.CONTRACTOR SHALL PROVIDECOLOR SAMPLES PRIOR TOCONSTRUCTION FOR APPROVAL BYOWNER OR LANDSCAPE ARCHITECT.SECTION - A 612"2'-11"7"112" ± 5'-11" 2" MIN. 4'-4"4" MAX., TYP. FINISHEDGRADE 1" TAPER CAP4x4 WOOD POST,6X6 POST ATCORNERS ANDGATES1" SQUAREALUMINUM RAIL,TYP.5/8" SQUAREPICKET, TYP. 1'-11"4"4"TYP. 4'-4"4' A A 1112" ELEVATIONSET TOP OFCONCRETE 1" BELOWFINISHED GRADE,SLOPE TO DRAINCOMPACTEDSUBGRADEEXISTING SUBGRADEFINISHED GRADEALUMINUM FENCE,REFER TO ELEVATIONAND MANUFACTURERSINFORMATIONCONCRETE FOOTING 4X4 WOOD POST,6X6 POST ATCORNERS ANDGATES OTHER INFORMATION:CONCRETE: 3,000 P.S.I. AT 28 DAYSSOIL COMPACTION: 95% STANDARD PROCTOR 8'4'-6"3'-112" 5'R2'-6" SIDE ELEVATION DIAGRAMFRONT ELEVATION(FOR DETAILED INFORMATIONREFER TO FRONT ELEVATIONTHIS DETAIL) R2'-6" 3" CUT WOOD ARCHFROM 6" X MATERIAL(OVERLAP LAPJOINTS 4" MIN.6"X6" WOOD ARCH2"X2" WOOD PERLINWRAP 6"X6" WOODPOST WITH 1"X4"WOOD TRIM 1/2"CHAMFER AT TOPAND BOTTOM, TYP.4"X6" WOOD POST WOOD FENCEMETAL HINGE,BLACK, BY OWNERSELF LATCHINGGATE MECHANISM,BLACK (MOUNT ONINTERIOR OF FENCE1"X4" WOODBOARDS, TYP.1"X4" WOOD FRAME,TYP.FINISHED GRADE5'-6" O.C.TABBY CONCRETEWALK 4" O.H.TYP.WOODPERLINWOODPOST NOTES:1.ALL LUMBER SHALL BE PRESSURE TREATED SOUTHER YELLOW PINE, COLOR TO MATCHSTUCCO ACCENT OR TO BE APPROVED BY OWNER.2.ALL CONNECTORS SHALL BE STAINLESS STEEL. ATTACHMENTS SHALL BE WITH STAINLESSSTEEL SCREWS SUITABLE FOR PRESSURE TREATED WOOD, NO NAILS SHALL BE USED.3.CONTRACTOR SHALL PROVIDE COLOR SAMPLES TO BE APPROVED BY OWNER'SREPRESENTATIVE. WOOD FENCEIN FRONTGATE BEYOND,REFER TOLAYOUT PLAN(SHEET L200)FOR GATELOCATION 3L601PATH LIGHTSCALE: NTS4L601UPLIGHTSCALE: NTS5L601STEP LIGHTSCALE: NTS OR EQUAL - SUBSTITUTIONS TOBE APPROVED BY OWNERS REP.OR EQUAL - SUBSTITUTIONS TOBE APPROVED BY OWNERS REP.OR EQUAL - SUBSTITUTIONS TOBE APPROVED BY OWNERS REP. Page 61 of 69 SITE DEVELOPMENT PLANSFORMEMORY MATTERSHILTON HEAD ISLAND, SOUTH CAROLINA DRAWING NUMBERDRAWING TITLE DESIGN CONCEPTS, DRAWING, SHEETS,LOGOS, SPECIFICATIONS, DETAILS,WRITTEN MATERIAL SHALL NOT BE USEDOR REPRODUCED IN WHOLE OR IN PARTIN ANY FORM WITHOUT PRIOR WRITTENCONSENT OF WJK LTD.© 2026 WJK LTD.THIS SHEET TO SCALE AT: 24"X36" DATE:PROJECT NO.:DRAWN BY:CHECKED BY:JUL 29, 202626056.01SDJC REVISIONS:DRB SUBMITTALPLAN, NOT FORCONSTRUCTION L602SITE DETAILS - 03 1L602WALL LIGHTSCALE: NTSOR EQUAL - SUBSTITUTIONS TOBE APPROVED BY OWNERS REP. 2L602SITE FURNISHINGSSCALE: NTS MANUFACTURER INFORMATION:LANDSCAPEFORMSKALAMAZOO, MI 29048PHONE: (800) 430.6209WEB: WWW.LANDSCAPEFORMS.COMMODEL: BASICCOLOR: FOGOTHER INFO: 23" BENCH WITH BACKAND ARMS; 60" FOUR SLAT TABLEOR APPROVED EQUAL TABLE AND CHAIRSBENCHGARDEN PLANTERS MANUFACTURER INFORMATION:LANDSCAPEFORMSKALAMAZOO, MI 29048PHONE: (800) 430.6209WEB: WWW.LANDSCAPEFORMS.COMMODEL: MELVILLE BENCHCOLOR: FOGOTHER INFO: 76" BACKED BENCHOR APPROVED EQUAL MANUFACTURER INFORMATION:VEGTRUGHATFIELD, PA 19440PHONE: (888) 908.2008WEB: WWW.US.VEGTRUG.COMMODEL: VEGTRUG CLASSIC 1.8MCOLOR: NATURALOR APPROVED EQUAL MANUFACTURER INFORMATION:EARTHEASYPHONE: (888) 451.6752WEB: WWW.EARTHEASY.COMMODEL: HARMONY ACCESSIBILITYSELF-WATERING CEDAR GARDENCOLOR: RAW CEDAROR APPROVED EQUAL Page 62 of 69 MEMORY MATTERS RENOV AION 15 TRELLIS COURT EXTERIOR COLORS & EXTERIOR LIGHT DETAILS Page 63 of 69 MEMORY MATTERS EXTERIOR COLORS As the Eurostone building is remodeled into the new home of Memory Matters, it is the intention that the materials on the exterior of the Four Season Room addition mimic the existing exterior colors. Therefore the metal roof and the window frames will be sage green, and the flyash horizontal siding will match the main beige stucco color. The flyash trim will be the same color as the existing stucco trim. New concrete walks will match existing concrete walks. Minor alterations to the paver parking lot will match the existing pavers. Page 64 of 69 ,.,.SAVOY HOUSE A LIGHTING NEW YORK STORE Q Find the products you'll love My Projects O e,, Lighting Fans Furniture & Decor Sale & Clearance Shop Collections Shop by Room o @ [si .G o ts·, - iii ii Savoy House I Lighting I Outdoor Lighting I Outdoor Wall Lights Er Stella Outdoor Flood Light in Bronze, Essentials by Savoy House SKU: 4-FLOOD-A2-3000K-BZ ix;;;; 0Reviews $37.40 s+4.00 Select Finish: Bronze 15% 0ffapplied. Details $37.40 s44.0o too+in stock) V Add to Cart Free Returns! Details 9 No Restocking Fee Q Bulbs Included Are you a Trade Professional? Log in to your LNY Pro account, or sign up here to receive exclusive trade pricing and other Pro benefits today! Original List Price: $67.00 (you save 34.39%) In stock items ship in 1-2 business days. CO Add to Project f Love the look of this product? Ex6 lore Similar St vies Recommended by LNY, Powered by Beacon 6' Request Price Alert Page 65 of 69 #SAVOY HOUSE A LIGHTING NEW YORK STORE Q Find the products you'll love My Projects O e,, Lighting Fans Furniture & Decor Sale & Clearance Shop Collections Shop by Room pt Stella Outdoor Flood Light in Bronze, Essentials Product Specifications EER Product Information Brand: Savoy House Brand Category: Outdoor Flood Light Brand Product Description: LED Double Flood Light in Bronze Shipping Method: Ground SKU: 4-FLOOD-A2-3000K-BZ UPC:822920311383 Electrical and Operational Information Color Rendering Index: 80 Color Temperature: 3000K Dimmable: No Lamping Category: LED Lamping Features: LED Delivered Lumens: 1600 Lamping Included: Bulbs Included Lamping Type: Integrated LED Lumens: 1600 Primary Number of Bulbs: 2 Socket: Integrated LED Total Number of Bulbs: 2 Voltage: 120V Wattage Max: 22.00 Dimensions and Measurements Backplate/Canopy Extension: 1.77 Backplate/Canopy Height: 5 Backplate/Canopy Width: 5 Height: 4.13 Weight: 1.56 Width:7.87 Warranty and Specifications Prop 65: Yes UL Ratings: ETL Wet Additional Details Features: • Maximum Extends: 6.5 • Assembly Required: Minimal Required • Maximum Extends: 6.5 • Minimal Assembly Required Material: Aluminum/ Glass Page 66 of 69 972-535-0926 | PLTSOLUTIONS.COM | ver 021723 WATTAGE AND COLOR SELECTABLE LED CANOPY FIXTURE FEATURES WARRANTY LISTINGS THERMAL INSTALLATION ELECTRICAL CONSTRUCTION PERFORMANCE DESCRIPTION project name type catalog number comments voltage approved by date • Up to 157 LPW ultra-high efficiency delivers superior performance over older fixtures • Replaces 50W, 150W, or 250W metal halide fixtures • Lumen output varies depending on the wattage and color temperature selected; see Selectable Table for full breakdown • Wattage and color temperature are adjusted via dip switches on the side of the fixture underneath clear plastic knockouts; see installation instructions for more information • 0-10V dimming; see Compatible Dimmers section for full list of compatible dimmers • 5 year limited warranty; see pltsolutions.com for warranty details • IP65 Rated • UL Listed for wet locations • IK10 • DesignLights Consortium® 5.1 Premium - meets the requirements for the highest DLC qualification for efficacy and lumen maintenance • -22°F to 113°F (-30°C to 45°C) operating temperature • Designed for pendant or surface mounting with J-box (not included); see installation instructions for more information • THD: ≤20% • Power Factor: ≥0.9 • Input Voltage: 120-277V • Dimmable power supply (0-10V) • Surge Protection: 4kV • Low-profile aluminum alloy housing with white finish • PC lens • CRI: >80 • CCT: 3000K, 4000K, 5000K • LED L70 Life Hours: 160,000 hours • BUG: B1-U3-G1, B1-U3-G2, or B1-U3-G3 A long-lasting and highly efficient replacement for metal halide fixtures, use this wattage and color selectable LED canopy light to improve outdoor security lighting. APPLICATIONS • Warehouses • Factories • Hospitals • Hotels • Offices 1 Page 67 of 69 972-535-0926 | PLTSOLUTIONS.COM | ver 021723 Item # Watts* CCT CRI Lens Dimming Voltage Replaces BUG DLC # DLC Level PLT-12486 10/ 15/ 20 3000K/ 4000K/ 5000K >80 PC 0-10V 120-277V MH50 B1-U3-G1 PLTSNM111141 5.1 Premium PLT-12487 20/ 30/ 40 3000K/ 4000K/ 5000K >80 PC 0-10V 120-277V MH150 B1-U3-G2 PLTSNM211141 5.1 Premium PLT-12488 40/ 60/ 70 3000K/ 4000K/ 5000K >80 PC 0-10V 120-277V MH250 B1-U3-G3 PLTSNM311141 5.1 Premium 2 PERFORMANCE SUMMARY SELECTABLE TABLE COMPATIBLE DIMMERS * See Selectable Table for full breakdown Item # Wattage CCT Lumen Efficacy PLT-12486 10 3000K 1328 133 4000K 1400 140 5000K 1393 139 15 3000K 1899 127 4000K 2031 135 5000K 2060 137 20 3000K 2656 133 4000K 2860 143 5000K 2892 145 PLT-12487 20 3000K 2767 138 4000K 2984 149 5000K 3032 152 30 3000K 4038 135 4000K 4394 146 5000K 4398 147 40 3000K 5010 125 4000K 5399 135 5000K 5462 137 PLT-12488 40 3000K 5696 142 4000K 6188 155 5000K 6283 157 60 3000K 7743 129 4000K 8710 145 5000K 8695 145 75 3000K 9363 125 4000K 9812 131 5000K 9977 133 Brand Model Legrand RH4FBL3PTC Leviton IP710-DLZ Leviton DS710-10Z Lutron NTSTV-DV-WH Lutron NFTV-WH Lutron DVSTV-WH Page 68 of 69 972-535-0926 | PLTSOLUTIONS.COM | ver 021723 3 DIMENSIONS PHOTOMETRICS PL T-12486 DIMENSIONS: PL T-12486 PHOTOMETRICS: PL T-12487 DIMENSIONS PL T-12487 PHOTOMETRICS: PL T-12488 DIMENSIONS: PL T-12488 PHOTOMETRICS: Length: 8.03" Height: 3.5" Width: 8.03" Weight: 2.98 lbs Length: 8.03" Height: 3.5" Width: 8.03" Weight: 3.9 lb Length: 10" Height: 3.9" Width: 10" Weight: 6.26 lbs 8.03" 8.03" 3.5" 3.5" 3.9" 8.03" 8.03" 10" 10" Page 69 of 69

Source: Town of Hilton Head Island website. First collected Oct 13, 2026.