Design Review Board Meeting — Agenda Packet
Town of Hilton Head Island · Beaufort County · Design Review Board · meeting of Aug 26, 2026 · Agenda packets
Open the original document More from Town of Hilton Head Island
Text
Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.
Town of Hilton Head Island
Design Review Board Meeting
Wednesday, August 26, 2026, 2:30 PM
1 Town Center Court, Hilton Head Island, SC
Benjamin M. Racusin Council Chambers
The Design Review Board meeting will be held in person at Town Hall in the
Benjamin M. Racusin Council Chambers.
1. Call to Order
2. Adoption of the Agenda
3. Approval of the Minutes
a. Regular Meeting Minutes of August 12, 2026
4. Unfinished Business
5. New Business
a. DRB-000747-2026 – 15 Trellis Court – Alteration/Addition
6. Public Comment - Non Agenda Items
7. Board Business
8. Staff Reports
a. Update on Design Guide.
b. Report on minor projects not coming to Design Review Board.
9. Adjournment
FOIA Compliance: Public notification of this meeting has been published, posted, and
distributed in compliance with the South Carolina Freedom of Information Act and the
requirements of the Town of Hilton Head Island.
In accordance with the requirements of Title II of the Americans with Disabilities Act of
1990 ("ADA"), the Town of Hilton Head Island will not discriminate against qualified
individuals with disabilities on the basis of disability in its services, programs, or
activities. Auditory accommodations are available. Any person requiring further
Page 1 of 69
accommodation should contact the Town of Hilton Head Island ADA Coordinator as
soon as possible but no later than 48 hours before the scheduled event.
Municipal Association of South Carolina (MASC) Civility Pledge:
“I pledge to build a stronger and more prosperous community by advocating for civil
engagement, respecting others and their viewpoints, and finding solutions for the
betterment of my city or town.”
Page 2 of 69
Town of Hilton Head Island Design Review Board
Meeting Minutes
8/12/2026 Page | 1
Town of Hilton Head Island
DESIGN REVIEW BOARD MEETING
Wednesday, August 12, 2026, 2:30 PM
Minutes
1. Call to Order
Chair Parker called the meeting to order at 2:30 pm. In attendance were: Chair Parker, Megan
Fitzpatrick, Cathy Foss, Patty Pastor and Judd Carstens. Due to a conflict, Annette Lippert
and Todd Theodore were excused.
2. Adoption of the Agenda
Judd Carstens moved to adopt the Agenda as presented. Cathy Foss seconded. The motion
passed unanimously.
3. Approval of the Minutes
a. Regular Meeting Minutes of July 22, 2026
Cathy Foss moved to approve the Minutes of July 22, 2026. Patty Pastor indicated two
changes. Megan Fitzpatrick seconded. The motion passed unanimously.
4. Unfinished Business
5. New Business
a. DRB-000751-2026 - 40 Waterside Drive - Final
Kendal Wagner presented 40 Waterside Drive Final as included in the agenda packet.
The applicant answered questions from the Board. Patty Pastor moved to approve with
the following conditions: the board concurs with the majority of staff comments, with a few
exceptions. Regarding 2) the pavilion roofline, the board agrees that the original design is
more appropriate than the stack. With regard to 4) pool shower screening, the applicant
has indicated the area currently located at the front will become just a foot washing
station. The shower in the back will become a full-head shower rinsing area; punched
metal screen — the majority of the Board agrees that the current metal screen is
appropriate; the chain-link fence will be changed to be similar to the pool fence regarding
the site furnishing palette, as well as the bike rack color; agreement with regard to the
detectable warning service. In addition to the changes to staff comments above, make
note regarding the placement of the 120 wall sconces as well as the 25 recessed lights.
Top seating was removed. Therefore, there was no requirement to provide photo metrics
regarding the TVs; study the color of the pool building downspout; provide additional
information regarding the spa that was added from the conceptual design; remove the
African Iris and replace them with Holly or Podoocarpos. Megan Fitzpatrick seconded.
The motion passed unanimously.
Page 3 of 69
Town of Hilton Head Island Design Review Board
Meeting Minutes
8/12/2026 Page | 2
6. Public Comment - Non Agenda Items
Skip Hoagland spoke on multiple topics, including current taxes, accommodations, hospitality
and the budget.
7. Board Business
8. Staff Reports
There were no staff reports. Patty Pastor requested an update on the Design Guide and Chair
Parker requested an update on projects that are going through minor approvals that do not
come before the Board.
9. Adjournment
The meeting was adjourned at 3:21 pm.
Page 4 of 69
MEMORY MATTERS RENOV AION
15 TRELLIS COURT
“ADDITION” REVIEW
AUGUST 26, 2026
DRB-000747-2026
Page 5 of 69
1
PROJECT NAME: MEMORY MATTERS RENOVATION DRB#: DRB-00747-2026
DATE: 08/26/2026 CATEGORY: Alteration/Addition
RECOMMENDATION: Approval Approval with Conditions Denial
APPLICATION MATERIAL
DRB REQUIREMENTS Complies
Yes
No
Not Applicable Comments or Conditions
Demolition Plan if needed
Existing Conditions match As-Built
Dimensioned Details and of Sections
Detail Illustrating Connection to Existing Structure
New Building Details Match Existing Building Details
ARCHITECTURAL DESIGN
DESIGN GUIDE/LMO CRITERIA Complies
Yes
No
Not Applicable Comments or Conditions
Structure is designed to be appropriate to the
neighborhood
Promotes pedestrian scale and circulation
Design is unobtrusive and set into the natural
environment
Utilizes natural materials and colors
Avoids distinctive vernacular styles
Design is appropriate for its use
All facades shall have equal design characteristics
DESIGN TEAM/DRB COMMENT SHEET
The comments below are staff recommendations to the Design Review Board (DRB)
and do NOT constitute DRB approval or denial.
Page 6 of 69
2
Avoids monotonous planes or unrelieved repetition
Has a strong roof form with enough variety to provide
visual interest
Overhangs are sufficient for the façade height.
Forms an details are sufficient to reduce the mass of the
structure
Human scale is achieved by the use of proper proportions
and architectural elements
Utilizes a variety of materials, textures and colors
Using same materials and colors as the existing
building. Color Board needs to be provided
Incorporates wood or wood simulating materials
Windows are in proportion to the facade
Details are clean, simple and appropriate while avoiding
excessive ornamentation
Utilities and equipment are concealed from view
Decorative lighting is limited and low wattage and adds
to the visual character
Accessory elements are designed to coordinate with the
primary structure
LANDSCAPE DESIGN
DESIGN GUIDE/LMO CRITERIA Complies
Yes
No
Not Applicable Comments or Conditions
Treats the Landscape as a major element of the project
Provides Landscaping of a scope and size that is in
proportion to the scale of the development
Landscape is designed so that it may be maintained in
its natural shape and size
Preserves a variety of existing native trees and shrubs
Provides for a harmonious setting for the site’s
structures, parking areas or other construction
Location of existing trees and new trees provides
street buffers, mitigation for parking lots, and an
architectural complement that visually mitigates
between parking lots and building(s)
Shrubs are selected to complement the natural setting,
provide visual interest and screen less-desirable
elements of the project
A variety of species is selected for texture and color
Provides overall order and continuity of the
Page 7 of 69
3
COMMENTS & CONDITIONS
1. Staff recommends approval with conditions:
a. Physical color board be provided,
b. Other plan reviews submitted (Minor Development Plan Review)
Landscape plan
Native plants or plants that have historically been
prevalent on the Island are utilized
A variety of sizes is selected to create a “layered”
appearance for visual interest and a sense of depth
The location of existing mature trees is taken into
account in placement of shrubs so as not to damage
tree roots
Proper spacing and location for plants to reach their
mature size and natural shape while avoiding
excessive or unnatural pruning
Proposed groundcovers are evergreen species with
low maintenance needs
Large, grassed lawn areas encompassing a major
portion of the site are avoided
The adjacent development is taken into account in
determining the most appropriate buffer so as not to
depart too dramatically from the neighborhood
Ornamentals and Annuals are limited to entrances and
other focal points
NATURAL RESOURCE PROTECTION
DESIGN GUIDE/LMO CRITERIA Complies
Yes
No
Not Applicable Comments or Conditions
An effort has been made to preserve existing trees and
under story plants
Supplemental and replacement trees meet LMO
requirements for size, species and number
Wetlands if present are avoided and the required
buffers are maintained
Sand dunes if present are not disturbed
Page 8 of 69
MEMORY MATTERS RENOV AION
15 TRELLIS COURT
PROJECT NARRATIVE
Page 9 of 69
Town of Hilton Head Island
1 (z.q
Community Development Department
1Town Center Court
Hilton Head Island, SC 29928
Phone 843-341-4757 Fax 843 341 2087
hiltonheadslandcgoy
FOR OFFICIAL USE ONLY
ate Received
Accepted by
so». Tr72@
APPLICATION PACKET FOR
MAJOR CORRIDOR REVIEW (MAJOR DPR)
Applicant Property Owner
,Name: JVD CA@TN Name: ww04 W+Tc-?S
Phone:3 7$7 7f e Phone: 843 8f ii88Mailing Address: Po [30x 303, Mailing Address: ( Ts ouTvft(ox, $- 744[o +Ht,s 44£mat: JvO Q wuJl TD,r Email: JI@ MY 404 wAT-rs.oTown Business License # (if applicable): J[ Ho&Np x.If1
Project Information
Parcel Number(w)RS_II @@ do 6fG 0@oProject Name:
woq wAP$ %v4 7oJProject Address. (5 -TR€AS ougTzoning District A4HT iNpus1{k, [overlay District(s): o - eC+Project Description-
p3u(DIN, No/A4T70Nl J] A<<SS[3eRAMP AD oUToR q42DN SRA.Project Category:
[]Concept Approval- Proposed Development
D Final Approval- Proposed Development
2Aeration/Addo]sen
»e7,28.¢
one 7-32
Are there recorded private covenants and/or restrictions that are contrary to, conflict with, or prohibit the
proposed request? If so, a copy of the private covenants and/or resyictions must be submitted with this
application [vEsor voDisclaimer: The Town of Hilton Head 1sland assumes no legal or financial liability to the applicant or any third party whatsoever
by approving the plans associated with this permit.
I hereby acknowledge by my signature below that the foregoing application is complete and accurate and that lam the owner of
the subject property As applicable, 1authorize the subject property to be posted and inspected
oeroo«is«ore \Ai'be)std loApplicant Signature:
U'
tAL
Town of Hilton Head Island Major Corridor Review Application Updated 1 11 2025
Page 10 of 69
Town of Hilton Head Island
Community Development Department
1 Town Center Court
Hilton Head Island, SC 29928
Phone: 843-341-4757 Fax. 843-341-2087
hilt9nhead1slands.gay
ROrFIAL USE ONLY
Date Received
Accepted
b~ -Perm«._/'1_l]lg
Town of Hilton Head 1sland Affidavt of Ownership
w'.~E5Sm.
y hand
~nd
official seal this 3 day of J\.1
\1 .A.O., 2~.
lo /'ya_ w» conmssion ere,, _MALy 1,03/w«tar PuelSignature Peeletoramp
AFFIDAVIT OF OWNERSHIP AND HOLD HARMLESS PERMISSION TO ENTER PROPERTY
The undersigned being duly sworn and upon oath states as follows:.l. lam the current owner of the property which is the subject of this application.2. 1hereby authorize_JUDD ApsT; toat as my agent for this application only.3. All statements contained in this application have been prepared by me or my agents and are true and correct to the bestof my knowledge.
4. The application is being submitted with my knowledge and consent.S. Owner grants the Town, its employees, agents, engineers, contractors or other representatives the right to enter uponOwner's real property, located at {A cov?T (address),
RSL[9goo44g_9Q90 (parcel t) for the purpose of application review, for the limitedtime necessary to complete that purpose.
oescrotvon ot work: _EtpNq PKvAto! AND CqAP-N PRa!T6. Owner agrees to hold the Town harmless for any loss or damage to persons or property occurring on the private propertyduring the Town's entry upon the property, unless the loss or damage is the result of the sole negligence of the Town.7. 1acknowledge that the Town of Hilton Head Island Municipal Code requires that all construction in a Special Flood HazardZone be constructed in accordance with the following provisions that:a. any enclosed area below the base flood elevation will be used solely for parking of vehicles, limited storage oraccess to the building. This space will never be used for human habitation without first becoming fully compliantwith the Town's Flood Damage Controls Ordinance in effect at the time of conversion.b. all interior walls, ceilings and floors below the base flood elevation will be constructed of flood resistant materials.c. all mechanical, electrical and plumbing devices will be installed above base flood elevation.d. walls of the enclosed area below base flood elevation will be equipped with at least two openings which allowautomatic entry and exit of flood water. Openings will be on two different walls with at least one square inch offree area for every square foot of enclosed space and have the bottom of openings no more than a foot above
grade
e. the structure may be subject to increased premium rates for flood insurance from the National Flood Insurance
Program.
8. 1understand that failure to abide by Town permits, any conditions, and all codes adopted by the Town of Hilton HeadIsland deems me subject to enforcement action and/or fines.
rnrt are: aJi IL ae; l6,sly ±stowner se»ore. _]]Bae&dg_]lay_ oe: 7-3-22,none No.. _ms:_l]lg hu nenay nalk_. A
The foregoing instrument was acknowledged before me /\[_(9y(gy5[._['Ms persona[y knayn to me or ha,troacea BL ((Lp_ _as6enutation and who did or take a am ",%%s4" ; NoTAR
- Puc -{
-,: wco i-7: 0»z4 ; ?-·.,°..o'°·,Os_,ssv,7UTT,'Jkceat 8/22/202
Page 11 of 69
.ases,"ua",/•,.d•o,opo :rotoitoaturo 0tan«t plaanns nu
Addition/ Alteration Corridor Review Narrative
Memory Matters Renovation15 Trellis Court, Hilton Head Island, SC 29926
147-2¢
This project proposes interior and exterior renovations to the building and outdoor garden space
construction for the re-located Memory Matters organization at 15 Trellis Court.
This project involves improvements to the building and grounds on the 2.38-acre Light Industrial zoned
parcel (RS11 008 000 0446 0000) within the Capital Business Park. The parcel was developed in 2006 for contractor
offices and showroom space. The future user, Memory Matters, is an organization aimed at supporting and engaging
those with Alzheimer's and dementia, their caregivers and family, and related health care providers. The primarily
day-time use and alternative transportation focus of users (busing or caregiver carpool) are important aspects of
property utilization. The existing lagoon will be retained and bulkhead untouched, along with the large live oaks
around the building (5 significant and 1 specimen) and existing paver parking lot. A fenced outdoor garden space will
be added adjacent to the building in an existing lawn area. This space is aimed at outdoor exploration and
programming for the Memory Matter users, allowing them to engage (garden in raised planters) and be active (social
spaces and classroom learning) within nature. The lagoon and untouched buffers along Leg O'Mutton Road and
Marshland Road provide a great backdrop for the western and southern edges of the sire.
Construction activities planned for the site will be limited. Tree removal is isolated and focused on providingthe garden space on the western edge of the site, as well as some pine tree removals for drainage purposes on the
building corner closest to Trellis Court. All tree removal is mitigated, as well as street-front buffer addressed at Trellis
Court. Grading overall is limited and associated with the garden space and improved ADA access to the front door
from drop-off - the architect has coordinated covered accessible ramp system with existing parking lot paving and
curbs. Landscape and tree areas along eastern property boundary and parking are to remain untouched.
The renovation of the building and inclusion of outdoor engagement space will support the important work
of Memory Matters within our island community. The work will also allow the use of a previously developed site to
continue in a productive manner, supporting building re-use and environmental goals for Hilton Head Island.
Sincerely,
Judd Carstens, RLA
Attachment -- DRB Form
23 Promenade St. Ste 201
Bluffton, SC 29910
Tel: 843.757.7411
Page 12 of 69
Town of Hilton Head Island
MAJOR CORRIDOR REVIEW APPLICATION
Minimum Requirements for Submittal
[An Application Review Fee as determined by the Town of Hilton Head Island Master Fee Schedule. Checks
payable to Town of Hilton Head Island. To I PAw 4 owAcompleted Affidavit of ownership
D Private covenant and/or restrictlons, if applicable. M { ,'\
In Addition:
For Concept Approval- Proposed Development
[] Asurvey (1"=30' minimum scale) of property lines, existing topography and the location of trees meeting
the tree protection regulations of Sec. 16-6-104, Tree Protection, and if applicable, location of bordering streets,
marshes and beaches. Site Plan (1"-30' minimum scale) showing location of existing development.
[] A site analysis study to include specimen trees, access, significant topography, wetlands, buffers, setbacks,
views, orientation and other site features that may influence design.
D A draft written narrative describing the design intent of the project, its goals and objectives and how it reflects
the site analysis results.
D Context photographs of neighboring uses and architectural styles.
D Conceptual site plan {to scale) showing proposed location of new structures, parking areas and landscaping.
D Conceptual sketches of primary exterior elevations showing architectural character of the
proposed development, materials, colors, shadow lines and landscaping.
For Concept Approval- Proposed Development
[] Afinal written narrative describing how the project conforms with the conceptual approval and design review
guidelines in the Design Guide.
[ Final site development plan meeting the requirements of D-6.F, Site Development Plan.
[] Final site lighting and landscaping plans meeting the requirements of D-6.1. Site Lighting Plan and D-6.H.
Landscape Plan.
[] Final floor plans and elevation drawings (1/8"=1'0" minimum scale) showing exterior building materials and
colors with architectural sections and details to adequately describe the project.
D A color board (ll"x17" maximum) containing actual color samples of all exterior finishes, keyed to the
elevations, and indicating the manufacturer's name and color designation.
D Any additional information requested by the Design Review Board at the time of concept approval, such as scale
model or color renderings, that the Board finds necessary in order to act on a final application.
For Concept Approval- Proposed Development
~All of the materials required for a final approval of a proposed development (see previous section).
)(.A survey (1"=30' minimum scale) of property lines, existing topography and the location of trees meeting
the tree protection regulations of Sec. 16-6-104, Tree Protection, and if applicable, location of bordering streets,
marshes and beaches.
)( Photographs of existing structure{s).
Town of Hilton Head Island Major Corridor Review Application Updated I I I 1 2025
Page 13 of 69
For Concept Approval- Proposed Development
D Accurate color ren rings of sign showing di nsions, type of lettering, and actual color samples.
DO For freestanding signs:
o Site plan (1"=30' minim! scale) s)owing location of the sign in relation buildings, parking, existing signs,and property lines.
o Propose landscaping plan.
[] For wall signs:
o Photograph or drawil of the building di cting the proposed location of the sign.
o Location, fixture e, and wattage of any pr osed lighting.
J
Applicant Signature: te: 7.28.2
Town of Hilton Head Island Major Corridor Review Application Updated 11 11 2025
Page 14 of 69
MEMORY MATTERS RENOV AION
15 TRELLIS COURT
ARCHITECTURE PLANS
Page 15 of 69
A R CH ITECT S
A R CH ITECT S
parkerdesigngrouparchitects
843 785 5171 POST OFFICE BOX 5010 HILTON HEAD ISLAND SC 29938
A facility upfit for:
Hilton Head Island, South Carolina
Memory MaƩers
REVISIONS DATE
DATE OF ISSUE:
SHEET
SGK
SCALE
DRAWN BY
CHECKED BY
JOB NO.
These documents & designs are
the property of Parker Design
Group|Architects & are not to
be used or reproduced there of or
for designs, working drawings,
or construction of buildings
without the written authorization
from the copyright owner
PDG|Architects 2025 copyright C
2546
@ 15 Trellis Court
FOR
FINAL
STATE REVIEW
C.1.0
COVER SHEET
7/27/2026
WTP
DPH PROJECT
#1016806
F
DW
ICE
BUFFET
RAMP DOWN
TO SENSORY GARDEN
OFFICE
OFFICE
FLEX WORKSPACE
LAUNDRY
& JAN
OFFICE
15'-8" X 9'-0"
CLASSROOM
STAFF
COFFEE
GUEST &
PATIENT
R.R.
STAFF
R.R. ADA
ELEC.
ELEC.
BULLETIN BOARD
PASS-
THRU
SERVING
COUNTERSTOR.
MUSIC ROOM
FENCE & GATES TBD
ART ROOM
GENERAL PROGRAM AREA
W.I.C.
PROGRAM
STORAGE
OFFICE
BRAIN GAME ROOM
22'-4" X 15'-2"
LOCKED
MEDS
LOCKED
FIRST AID
RESTING RM
UNLOCKED DOOR BETWEEN
THE TWO "ZONES" OF
THE BUILDING
CABINETS
ANTE
ROOM
ANTE
ROOM
STOR.
FROM DEDICATED
CATERING PARKING
CONFERENCE
LOBBY
19'-4" X 19'-1"
4'-0"
CASED
OPENING
NEW CASED
OPENING
N
DISPLAY
EXIST.
CASED
OPENING
STOR STOR
DISPLAY
AREA
RECEPTIONIST
ALCOVE
ALCOVE
WATER
ANTE
ROOM
STACKED
W/D
DESK &
DISPLAY
FOUR SEASONS
ROOM
COPIER
BY
OTHERS
BENCHBENCH
STACKED LOCKERS
TBD, TYPICAL
DW
NEW
REFRIG
HEATED
CABINETPANTRY
CATERING STYLE
KITCHEN
SUPPLIES
CHECK-IN/OUT
STAFFER STANDS
HERE WITH
MOBILE COMPUTER
TV ON WALL
ICE
SERVER
CLOSET
STORAGE T.B.D.
BUILT-IN
CABINET
DESK LEDGE
LAMINATE
DESK LEDGE
TRAVEL DISTANCE 93'-0"
TRAVEL DISTANCE 80'-0"
TRAVEL
DISTANCE
93'-0"
FEC
EXIT/EMERG SIGN
EXIT SIGN
EXIT/
EMER
SIGN
EXIT/
EMER
SIGN
EXIT/
EMER
SIGN
FEC
FEC
FEC
EXIT/
EMER
SIGN
EXIT/
EMER
SIGN
EXIT/
EMER
SIGN
EXIT/
EMER
SIGN
CL
FEC
67" ACTUAL DOOR EXIT WIDTH.
17.2" MIN. REQUIRED CLEAR WIDTH.
EXIT CAPACITY = 335 OCCUPANTS
67" ACTUAL DOOR EXIT WIDTH.
17.2" MIN. REQUIRED CLEAR WIDTH.
EXIT CAPACITY = 335 OCCUPANTS
33" ACTUAL DOOR EXIT WIDTH.
17.2" MIN. REQUIRED CLEAR WIDTH.
EXIT CAPACITY = 165 OCCUPANTS
RELOCATED
HVAC UNITS
DN
NEW
ROOF
LADDER
SPRINKLER
LEAN-TO
S/C
D
S/C
D
S/C
D
S/C
D
S/C
D
S/C
D
S/C
D
S/C
D
S/C
D
S/C
D
S/C
D
S/C
D
S/C
D
S/C
D
S/C
D
S/C
D
C
C
EXTERIOR
EXIT/EMERG LIGHT
EXTERIOR
EXIT/EMERG LIGHT
EXTERIOR
EXIT/EMERG LIGHT
EXTERIOR
EXIT/EMERG LIGHT
ELECTRIC DOOR
OPENER ON POST
EXIT SIGN
S/C
D
S/C
D
S/C
D
EXIT/
EMER
SIGN
EXIT/
EMER
SIGN
EXIT/
EMER
SIGN
EXIT/
EMER
SIGN
EMER
LIGHT
EMER
LIGHT
FENCE & GATE W/
ELECTRONIC BYPASS -
SEE LANDSCAPE
GARDEN
ENTRY
PATTY'S
SENSORY
GARDEN -
SEE LANDSCAPING
EMER
LIGHT
WH
FDCPIV
PRIVATE
OFFICE
PRIVATE
OFFICE
R.R.
DAYCARE
ENTRANCE
CONNECTION CONCRETE
SLOPES FROM 14.2 TO 14.1
PARKING
SPACE
PARKING
SPACE
PARKING
SPACE
PARKING
SPACE
EXIST.
CONCRETE
EXIST.
PLANTER
BREEZEWAY
H/C
SPACE
7''-0"
RAMP
@1:12
LANDING
13.4
NEW
CONC.
14.2
10'-0"
RAMP
@1:12
FLAT
CONCRETE
@ 12.8
BENCH BENCH
FLAT
CONCRETE
12.7
BENCH
CANOPIED
WALKWAYS
EXTEND
LANDSCAPE
CURB AS
REQUIRED
SCALE: 1/8" = 1'-0"
1CODE PLAN 1/8"
C.1.0
PLUMBING CALCULATION:
OCCUPANCY
MALE
WATERCLOSET
REQUIRED
TOTAL D.F.
REQ.
FEMALE
WATERCLOSET
REQUIRED
CODE ANALYSIS:
YES
ALLOWABLE BUILDING AREAS (Table 506.2):
Occupancy: NON-SEPARATED I-4 INSTITUTIONAL & BUSINESS
Sprinkler:
Type of Construction:
Design Criteria for Code Compliance as of:
VB
IBC 2021; IFC 2021 w/ SC amendments;DESCRIPTON:
Building Floor Areas: Actual Allowed
MALE LAV.
REQUIRED
FEMALE LAV.
REQUIRED
MALE
WATERCLOSET
PROVIDED
FEMALE
WATERCLOSET
PROVIDED
MALE LAV.
PROVIDED
FEMALE LAV.
PROVIDED
4,564 sqft
PROJECT TEAM
SCOPE OF WORK:
RENOVATION OF AN EXISTING BUILDING INTO TWO ZONES: ONE IS A BUSINESS OFFICE; THE SECOND PROVIDES ADULT DAYCARE. THE
BUILDING IS EMPTY EACH NIGHT. SINCE I-4 CODES ARE MORE RESTRICTIVE, THEY GOVERN THIS SPRINKLED, NONSEPARATED USE
BUILDING. 716 SF OF NEW SPACE IS BEING ADDED TO THE BUILDING ON THE EAST SIDE, WHICH IS WOOD FRAMING ON CMU STEM
WALLS. THE EXISTING BUILDING IS 1-STORY CONSTRUCTION ON A SLAB. THE EXISTING EXTERIOR WALLS HAVE A CMU CORE, WHILE
THE EXISTING INTERIOR WALLS ARE CONSTRUCTED WITH WOOD STUDS. MOST OF THE BUILDING HAS A METAL DECK ROOF. THERE
ARE NO SMOKE COMPARTMENTS REQUIRED IN THIS BUILDING.
INDEX OF DRAWINGS:
1-4 Institutional 1st Floor
ARCHITECT:
PDG-ARCHITECTS (TOM PARKER)
10 PALMETTO BUSINESS PARK SUITE 201, HILTON HEAD, SC 29928
843-348-2278
EMAIL: TOM@PDG-ARCHITECTS.COM
MECH., ELECTRICAL, PLUMBING:
LONDONO ENGINEERING
1011 BAY STREET, SUITE 307, BEAUFORT, SC 29902
PHONE: 843-263-1792
EMAIL: RLONDON@LONDONOENGINEERING.COM
TABLE 803.13 INTERIOR WALL AND CEILING FINISH REQUIREMENTS BY OCCUPANCY
GROUP
SPRINKLED
INTERIOR EXIT STAIRWAYS ,RAMPS
AND EXIT PASSAGEWAYS
CORRIDORS AND ENCLOSURE FOR
EXIT ACCESS STAIRWAYS AND RAMPS ROOMS AND ENCLOSED SPACES
I-4 B
TABLE 1017.2 EXIT ACCESS TRAVEL DISTANCE
WITH SPRINKLER
200 FEET ALLOWED
OCCUPANCY
I-4 Institutional
ACTUAL MAX DISTANCE
95' FEET
1.53 1I-4 INSTITUTIONAL 46 1.53
MOP SINK
REQ.
TOTAL 86 2.33 2.03 13 3
1
1
36,000 sqft
BB
2 2
STRUCTURAL:
LANDSCAPE ARCHITECTURE:
SHEARLOCK ENGINEERING LLC
110 TRADERS CROSS, SECOND FLR, OKATIE, SC, 29909
PHONE: 843-473-8767
EMAIL: JOSHUA@SHEARLOCKENG.COM
4,015 sqft 36,000 sqft
STRUCTURAL
MEP
THIS WRITTEN NOTICE REQUIRED BY SOUTH CAROLINA REGULATIONS TO THE PERMITTING
AUTHORITY & BUILDING OWNER THAT THE PDG-ARCHITECTS HAVE NOT BEEN HIRED TO PROVIDE
MINIMUM CONSTRUCTION ADMINISTRATION SERVICES ON THE FOLLOWING PROJECT.
BUSINESS (B) OCCUPANCY WITHOUT SPRINKLERS
REGULATION 11-12.B.4 AND 5 STATE:
(4) ON A PROJECT WHERE A BUILDING PERMIT HAS BEEN ISSUED AND THE SEALING
ARCHITECT AND THE FIRM OF
RECORD HAVE NOT BEEN ENGAGED TO PERFORM
AT LEAST MINIMUM CONSTRUCTION ADMINISTRATION SERVICES, AS DEFINED IN
SUBSECTION (5) BELOW, THE SEALING ARCHITECT AND FIRM MUST REPORT TO THE
PERMITTING AUTHORITY AND THE BUILDING OWNER THAT HE AND THE FIRM HAVE
NOT BEEN SO ENGAGED.
(5) THE MINIMUM CONSTRUCTION ADMINISTRATION SERVICES EXPECTED OF THE
SEALING ARCHITECT AND FIRM DEEMED
NECESSARY TO PROTECT THE HEALTH,
SAFETY, AND WELFARE OF THE PUBLIC SHALL BE PERIODIC SITE OBSERVATIONS OF
THE CONSTRUCTION PROGRESS AND QUALITY, REVIEW OF CONTRACTOR
SUBMITTAL DATA AND DRAWINGS, AND REPORTING TO THE BUILDING OFFICIAL
AND OWNER ANY VIOLATIONS OF CODES OR SUBSTANTIAL DEVIATIONS FROM THE
CONTRACT DOCUMENTS WHICH THE ARCHITECT OBSERVED.
CONSTRUCTION ADMINISTRATION NOTICE:
OCCUPANCYSQ.FT. / OCCUPANT
OCCUPANCY CALCULATIONS
USE OF SPACE SQ. FT.
I-4 INSTITUTIONAL 3,683 37100 GROSS
86TOTAL 8,577
THESE DRAWINGS HAVE BEEN PRODUCED UNDER A LIMITED SERVICES AGREEMENT FOR A REDUCED FEE BETWEEN THE OWNER/OWNER'SREPRESENTATION
& PDG-ARCHITECTS, INC. THEY ARE TO BE USED FOR DESIGN INTENT AND IN COORDINATION WITH SUPPLEMENT ENGINEERING DOCUMENTS.
1. THE ARCHITECT'S DRAWINGS CANNOT STAND ALONE AS CONSTRUCTION DOCUMENTS.
2. SEE STRUCTURAL ENGINEERING DOCUMENTS FOR STRUCTURAL CONNECTION TECHNIQUES, CALCULATIONS REQUIRED BY CODE, CODE COMPLIANCE
INSTRUCTIONS FOR WALL AND ROOF
CONSTRUCTION, AND TIE DOWN REQUIREMENTS.
3. SEPARATE MECHANICAL, ELECTRICAL, AND PLUMBING ENGINEERING DOCUMENTS ARE PROVIDED, WHICH INDICATE REQUIRED SERVICE AND RISER
DIAGRAMS, CALCULATIONS AND INSTALLATION SPECIFICATIONS
BEYOND THE ARCHITECTS BASIC LAYOUT AND SELECTIONS SUGGESTIONS.
4. SEPARATE CIVIL ENGINEERING DOCUMENTS ARE PROVIDED, WHICH INDICATE ADDITIONAL SITE PLANNING, DRAINAGE, AND OTHER RELATED SITE WORK
REQUIREMENTS.
5. SUBMITT ALL PAINT, PAPER, TILE, AND FINISHES AS PER OWNER FOR FINAL APPROVAL.SELECTIONS NOT INCLUDED IN THESE DOCUMENTS WILL BE
COORDINATED BY THE OWNER/ OWNER'S
REPRESENTATIVES.
6. BY APPLYING FOR A BUILDING PERMIT AND/OR CONSTRUCTING THE PROJECT REPRESENTED HEREIN, THE OWNER AGREES TO LIMIT THE LIABILITY OF THE
ARCHITECT, TO THE OWNER OF
THE PROJECT, FOR ALL AND ANY CLAIMS, LOSSES, DAMAGES OF ANY NATURE WHATSOEVER, OR CLAIMS OF EXPENSES FOR
ANY SUCH ITEMS TO THE ARCHITECTS TOTAL COMPENSATION FOR SERVICES RENDERED HEREIN.
7. THESE DOCUMENTS ARE THE WORK INSTRUMENTS OF THE ARCHITECT AND HAVE BEEN PREPARED SPECIFICALLY AND SOLELY FOR THE PROJECT NAMED
HEREIN. THEY ARE NOT SUITABLE
FOR USE ON OTHER PROJECTS OR IN OTHER LOCATIONS WITHOUT THE PARTICIPATION OF THE ARCHITECT.
REPRODUCTION IS STRICTLY PROHIBITED. THE ARCHITECT SHALL BE DEEMED THE AUTHOR AND OWNER OF THESE DOCUMENTS AND SHALL RETAIN COMMON
LAW, STATUTORY AND OTHER RESERVED RIGHTS, INCLUDING THE COPYRIGHT.
8. THE ARCHITECT HAS NOT BEEN CONTRACTED TO PERFORM CONSTRUCTION ADMINISTRATION/ ON-SITE OBSERVATION
FOR THIS PROJECT.
9. FOR DIMENSIONS NOT SHOWN OR IN QUESTION, THE CONTRACTOR WILL REQUEST CLARIFICATION FROM THE ARCHITECT BEFORE PROCEEDING.
10. CONTRACTOR WILL VERIFY ALL EXISTING CONDITIONS IN THE FIELD, ANY DISCREPANCIES WILL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT.
11. THE CONTRACTOR SHALL MAINTAIN
AT THE SITE OF THE WORK, A SET OF RECORD DRAWINGS. THE CONTRACTOR SHALL RECORD ALL CHANGES AND
DEVIATIONS FROM THE DRAWINGS ON THIS "AS-BUILT" SET, WHICH SHALL BE UPDATED A LEAST EVERY OTHER WEEK. AT THE CLOSE OF THE JOB, THE
CONTRACTOR SHALL PROVIDE ONE COMPLETE SET OF ALL AS-BUILT INFORMATION TO THE ARCHITECT IN CLEAR AND LEGIBLE FORMAT.
12. WHEN ARCHITECTURAL DRAWINGS ARE IN CONFLICT WITH ENGINEERING DRAWINGS THE GENERAL CONTRACTOR SHALL REQUEST CLARIFICATION FROM
THE ARCHITECT BEFORE PROCEEDING.
13. BEGINNING
OF WORK BY ANY TRADE SHALL CONSTITUTE ACCEPTANCE & RESPONSIBILITY FOR EXISTING CONDITIONS AND SUBSTRATE AS APPLICABLE
UNLESS OTHERWISE INIDCATED IN WRITING
PRIOR TO COMMENCEMENT OF WORK.
GENERAL NOTES:
ARCHITECTURAL & SITE
C.1.0 TITLE SHEET
A.1.1 FIRST FLOOR PLAN
A.1.0 AS-BUILT AND DEMO PLAN
S.1.2 PROPOSED SITE PLAN
VICINITY PLAN :
WITMER JONES KEEFER, LTD.
23 PROMENADE STREET, SUITE 201, BLUFFTON, SC 29910
PHONE: 843-757-7411
EMAIL: JUDD@WJKLTD.COM
B Business 1st Floor
B BUSINESS
49100 GROSS 4,894
B Business 1st Floor 300 FEET ALLOWED 105' FEET
40 0.80 1 1 0.50
3
2
1
3
2
1
B BUSINESS
A.1.2 REFLECTED CEILING PLAN
A.2.0 EXTERIOR ELEVATIONS
A.3.0 BUILDING & WALL SECTIONS
A.1.3 SCHEDULES & DOOR/WINDOW TYPES
A.5.0 ENLARGED FLOOR PLANS & ELEVATIONS
A.5.1 ENLARGED FLOOR PLANS & ELEVATIONS
A.1.4 FURNITURE PLAN
A.3.1 SECTIONS & DETAILS
CS COVER SHEET - LANDSCAPING
2021 International Codes for Plumbing, Mechanical, & Fuel Gas;
2020 National Electrical Code; 2009 International Energy Conservation Code (IECC);
South Carolina Dept. of Health Regulation 60-75 Stds for Licensing Day Care Facilities for Adults;
1.53
2.33
0.80
1.53
2.03
0.50
ANSI A117.1 2017
S100 STRUCTURAL NOTES
S201 FOUNDATION PLAN
S200 DEMOLITION PLAN
S203 CEILING FRAMING PLANS
S202 SLAB PLAN
S204 ROOF FRAMING PLANS
S210 SHEAR WALL PLAN
S300 FOUNDATION DETAILS
S400 STRUCTURAL DETAILS
S401 STRUCTURAL DETAILS
S402 STRUCTURAL DETAILS
M002 HVAC SCHEDULES
M001 HVAC DETAILS
M101 HVAC PLAN
E001 ELECTRICAL DETAILS
E002 ELECTRICAL SCHEDULES
E101 POWER PLAN
E101 LIGHTING PLAN
P001 PLUMBING DETAILS
P002 PLUMBING SCHEDULES
P101 SANITARY SEWER PLAN
P201 WATER DISTRIBUTION PLAN
L10 REFERENCE PLAN - EXISTING CONDITIONS
L50 DEMOLITION PLAN
L200 LAYOUT PLAN
L300 GRADING PLAN
L500 PLANTING PLAN
L501 PLANT SCHEDULE & DETAILS
L600 SITE DETAILS - 01
L600 SITE DETAILS - 02
6/16/26
Page 16 of 69
A R CH ITECT S
A R CH ITECT S
parkerdesigngrouparchitects
843 785 5171 POST OFFICE BOX 5010 HILTON HEAD ISLAND SC 29938
A facility upfit for:
Hilton Head Island, South Carolina
Memory MaƩers
REVISIONS DATE
DATE OF ISSUE:
SHEET
SGK
SCALE
DRAWN BY
CHECKED BY
JOB NO.
These documents & designs are
the property of Parker Design
Group|Architects & are not to
be used or reproduced there of or
for designs, working drawings,
or construction of buildings
without the written authorization
from the copyright owner
PDG|Architects 2025 copyright C
2546
@ 15 Trellis Court
FOR
FINAL
STATE REVIEW
S.1.2
RAMP ON SITE PLAN
7/27/2026
WTP
DPH PROJECT
#1016806
I
T
AC
CO
1/2" IPF
1/2" IPF
AC
AC
LOT 18
LOT 17
MARSHLAND ROAD 66' R/W
SINGLE STORY BUILDING
LEG OF MUTTON ROAD 50' R/W
TRELLIS COURT
LOT 19
15' BUILDING SETBACK
15' BUILDING SETBACK
BIKE PATH EASEMENT
15' BUILDING SETBACK
EDGE OF PAVEMENT
BIKE PATH
BIKE PATH
BIKE PATH
EDGE OF PAVEMENT
EDGE OF PAVEMENT
EDGE OF WATER
EDGE OF WATER
BACK OF CURB
BACK OF CURB
BACK OF CURB
15' BUILDING SETBACK
BACK OF CURB
EDGE OF PAVEMENT
WOOD FENCE
PAVER
DRIVEWAY
PAVER
DRIVEWAY
1.5' HEADWALL
1.5' HEADWALL
1' PLANTER
0.5' CONCRETE WALL
70.5'
66.4'
113.9'
122.1'
22.4'
111.2'
79.2'
1/2" IPF
W/CAP
CONCRETE
PATH
S.C. GRID
ISLAND DRIVE
INDIAN TRAIL
MARBLEHEAD ROAD
MARBLEHEAD ROAD
MARSHLAND ROAD
CAPITAL DRIVE
LEG-O-MUTTON ROAD
WHITNEY PLACE
VICTORIA SQUARE DRIVE
WOOD
DECK
TBM SET NAVD 88
ELEVATION = 15.01'
CONCRETE
TRAFFIC ISLAND
CONCRETE
TRAFFIC ISLAND
1.5' HEADWALL
0.5' CONCRETE WALL
RIP-RAP
EDGE OF WATER
TOP OF BANK
TOP OF BANK
1.5' HEADWALL
CONCRETE
SIDEWALK
CONCRETE RAMP
18" HDPE
18" HDPE
LAGOON
PLAT BOOK 102 PAGE 193
9
8
7
GRAVEL
EDGE OF WATER
FLOOD ZONE X N/A
FLOOD ZONE X SHADED N/A
FLOOD ZONE X SHADED N/A
FEMA FLOOD LINE
VICINITY MAP
N.T.S.N.T.S.
THIS DOCUMENT ORIGINALLY ISSUED AND
THIS ELECTRONIC MEDIA SHALL NOT BE
A CERTIFIED HARDCOPY MAY BE OBTAINED FROM
SEALED BY JUSTIN R. KESSELRING S.C.R.L.S. # 29901
CONSIDERED A CERTIFIED DOCUMENT.
NANDINA, INC. UPON REQUEST
BEACHFRONT SETBACK REQUIREMENTS OF THE S.C. BEACH PROTECTION
3) SUBJECT PROPERTY DOES NOT APPEAR TO BE AFFECTED BY THE
1) UNDERGROUND UTILITIES NOT LOCATED EXCEPT AS SHOWN.
7) USE OF THIS PROPERTY MAY BE AFFECTED BY THE TERMS
OF COVENANTS RELATING TO THIS PLANNED COMMERCIAL DEVELOPMENT.
8) BUILDING SETBACKS, WHETHER SHOWN OR NOT, SHOULD BE VERIFIED
BY THE LOCAL BUILDING AUTHORITY OR ARCHITECTURAL REVIEW BOARD.
BASE FLOOD ELEVATION = N/A
THIS PROPERTY LIES IN F.E.M.A. ZONES X & X SHADED
PROPERTY AREA = 2.39 Ac. 103,917 Sq. Ft.
RECORDED IN BOOK 58, PAGE 153
BEAUFORT COUNTY, SC
COMMUNITY NO. 450250, PANEL 0454G, DATED: 3/23/2021
ADDRESS: 15 TRELLIS COURT
DISTRICT: 511, MAP: 8, PARCEL: 446
REFERENCE PLATS
ROD.
BY:
1) A SUBDIVISION PLAT OF 19 LOTS AT THE A. J. TRUST SITE,
DRAWN: 10/14/1996
A SECTION OF MARSHLAND ROAD & LEG O'MUTTON ROAD AREA,
JACK JONES S.C.R.L.S. #13852
ACT OF JULY 1, 1988.
NOTES:
4) HORIZONTAL DATUM IS S.C. STATE PLANE COORDINATES NAD83.
5) VERTICAL DATUM IS NAVD88.
6) CONTOUR INTERVAL IS 1'.
9) THIS SURVEY HAS BEEN PREPARED WITHOUT BENEFIT OF A COMPLETE
TITLE SEARCH AND IS SUBJECT TO EASEMENTS AND RESTRICTIONS OF RECORD.
COPYRIGHT BY NANDINA, INC. CAD: INDOVANCE, FLD: CM, RB
SCALE :DATE : 1" = 20'
HILTON HEAD ISLAND,
LOT 18, CAPITAL BUSINESS PARK,
BEAUFORT COUNTY, SOUTH CAROLINA
09/30/2025
ASBUILT, TREE AND TOPOGRAPHIC SURVEY OF:
d.b.a. Sea Island Land Survey, Inc.
DWG No. :FILE No : 25308 5-25308 E
6040200
GRAPHIC SCALE
E-mail: admin@nandinainc.com
Hilton Head Island,
SC 29926
Tel (843) 681-3248
PREPARED FOR: EURORISORE , LLC
10) THIS SURVEY DOES NOT CERTIFY TO THE EXISTENCE OR ABSENCE OF
FRESHWATER WETLANDS.
2) NANDINA, INC. CERTIFIES TO THE BOUNDARY, TOPOGRAPHIC
AND ASBUILT INFORMATION PROVIDED HEREON AS THE DATE OF THE
SURVEY. THIS SURVEY MAY BE USED IN DIGITAL FORMAT AS A BASE
FOR OTHERS AND ANY REVISIONS OR ADDITIONS MADE HEREAFTER IS NOT THE
RESPONSIBILITY OF NANDINA, INC. A HARD COPY AVAILABLE FROM
NANDINA, INC. WILL BE THE ONLY OFFICIAL DOCUMENT.
11) IF IDENTIFICATION OF TREES IS CRITICAL TO DEVELOPMENT, AN ARBORIST
SHOULD BE CONSULTED TO VERIFY SUCH TREE IDENTIFICATION.
10 Oak Park Drive, Unit C1,
INVERT ELEVATION
POLYVINYL CHLORIDE
MAPLE
PALM
WATER OAK
IE
PVC
LIVE OAKLO
LAUREL OAKLA
MAP
PECANPEC
PINEPN
PLM
WO
TREE SIZES ARE INCHES IN DIAMETER
3" CONCRETE MONUMENT FOUND
SPOT ELEVATION
TEMPORARY BENCH MARK
9
LEGEND & SYMBOLS:
TBM
9.5
CONTOUR
3" CMF
SUGAR BERRYSB
REINFORCED CONCRETE PIPERCP
HIGH DENSITY POLYETHYLENE PIPEHDPE
1/2" IRON PIN FOUND1/2" IPF
AC A/C UNIT
COMMUNICATION VAULTT
TELEVISION SERVICE
CLEANOUTCO
GRATE INLET
IRRIGATION CONTROL VALVEI
SIGN
TELEPHONE SERVICET
ELECTRIC TRANSFORMER
WATER METER
CHERRYCH
TUPELOTUP
HILTON HEAD ISLAND, BEAUFORT COUNTY, SOUTH CAROLINA
SITE
WATER OAKWO
RECORDED IN BOOK 102, PAGE 193, DATED 12/02/2004
BEAUFORT COUNTY, SCROD.
BY:
2) BIKE PATH EASEMENT OVER LOT 18, CAPITAL BUSINESS PARK,
DRAWN: 2/13/2004
A SECTION OF MARSHLAND ROAD & LEG O'MUTTON ROAD AREA,
RALPH O. VANADORE S.C.R.L.S. #7606
HILTON HEAD ISLAND, BEAUFORT COUNTY, SOUTH CAROLINA
3
BSCK TPN GPS 2
4
X ON DW
22
BSCK PK GPS 1
11.1
10.8
11.2
11.3
11.1
11.3
11.5
11.4
11.5
11.8
11.8
11.9
12.1
11.9
11.9 12.0
12.0
12.2
12.3
12.1
12.2
12.1
12.2
12.4
12.3
12.3
12.3 12.3
11.6
11.7
11.9
11.8
11.7 12.1
12.3
12.3
12.3
12.3
12.4
12.4
12.8
12.9
12.9
12.8
12.8
12.7
12.712.712.7
12.1
14.3
14.3
14.3
ICV
WMWM
CATV
172
3X2 COM VAULT
173
4" COND174
TRNSFRMR
TEL PED
13.5
13.2
12.7
13.1
12.7
13.2
12.6
12.7
13.2 13.2
12.7
12.7
13.1
13.1 12.6
12.4
13.0
12.9
12.4
14.2
12.1
197
COR GI EP
198
COR GI EP
199
COR GI EP
200
COR GI EP
10.8
11.1
PLM 14
12.1
PLM 16
LAO 8
LAO 8
PN 20
LAO 9
PN 16
PN 18
PN 16LAO 9
PN 20
PLM 13
PLM 12
PLM 14
PLM 8
PLM 9
PLM 16
PLM 16
LAO 8
PN 12
WO 10
PN 16
MAP 9
PN 24
CYP 6
LO 15
LO 17
231
BSCK PK GPS 1
12.8
13.3
13.3
13.3
13.3
13.413.3
13.4
13.4
13.2
PLM 14
PLM 13
CO
PLM 14
LO 5-9-10-11-13-16-17
14.2 12.7
11.8
12.4
LO 13-16-19
13.8
11.9
12.5
12.4
LO 26
LO 6
PLM 16
PLM 14
PLM 13
12.2
11.9
12.3
12.3
12.2 12.2
12.1
11.9
12.0
12.0
11.9
11.7
11.9
12.1
12.112.2
12.3
12.5
12.4
12.0
12.3
12.2
10.3
PLM 16
LAO 9
11.6
LO 26
PN 26
PLM 12
WO 7
11.7
LO 15
LO 18
LAO 16
PN 6
11.2
PN 12
LO 28
10.5
12.4
8.6
309
BSCK X ON CON 4
PLM 16
13.0
12.4
12.4
12.9
13.1
12.6
12.7
12.7
14.0
14.014.0
13.4
13.4
13.2
13.1
12.9
12.7
13.1
13.2
14.2
14.3
14.3
14.0
13.9
13.4
13.5
13.1
13.313.4
13.4
14.1
14.1
12.7
12.7
13.2
12.9
12.5
12.412.9
12.9
12.5
12.2
12.8
11.9
12.1 12.1
12.1
12.0
13.9
PLM 10
11.6
13.7
LO 24
LO 15-22
13.3
11.9
PLM 28386
BSCK TPN 24
PLM 17
PLM 18
WO 7-19
MAP 6
392
11.193
DECK393
10.640
DECK
394
10.640
DECK
395
11.208
DECK
396
9.025
DECK397
8.958
DECK
398
8.950
DECK
399
9.028
DECK
400
9.533
STP
401
10.664
STP
402
10.665
STP
403
9.560
STP
11.9
PN 9
PN 6
PN 29
12.1
12.0
12.2
PN 9
PN 6-12PN 9
PN 11-12
11.2
6.9
11.2
6.8
10.1
420
7.092
IE 18 " HDPE
422
9.548
CLFE9.0
7.5
10.3
7.4
PN 17
PN 14
WO 13
9.9
7.3
WO 6
LAO 6
WO 8WO 8
10.5 7.2
PN 14
PEC 8
LO 12-14-17
LAO 6
6.8
PN 22
PN 22
TUP 6-6
PN 16
PN 9
PN 18
PN 18
WO 7
LAO 7
LAO 10
PN 7-8-21
PN 14
PN 19
10.0
7.2
462
BSCK TPN 24
PN 15
PN 19
LAO 6LAO 7
LAO 10 LAO 10
471
6.178
IE 18" RCP FLARE
472
6.146
IE 18" RCP FLARE
473
6.167
IE 24" RCP FLARE
474
6.289
IE 24" RCP FLARE
475
8.165
IE 15"HDPE
476
BSCK TPN 24
PN 20
PN 19
10.4
WO 7
10.2
LAO 7-7
LO 15
10.6
LO 19
LO 10
490
5.988
IE 18" HDPE
494
5.799
IE 18" HDPE
8.1
LO 24
10.0
LO 31
WO 8
WO 6
LAO 6
WO 7-7
WO 8 LO 10
LAO 7-7
LAO 8
LAO 7
LAO 7
LAO 11
CH 8
LAO 6
WO 10
LAO 6
WO 14
LAO 20
SB 11
LO 12 DEAD
WO 9
9.8
10.7
WO 8
PN 8
LAO 6
10.0
7.4
10.5
9.2
10.6
11.5
9.5
11.3
11.2
537
6.140
IE 18"HDPE
10.6
10.1
10.6
10.2
6.8
10.5
6.7
LAO 13
CH 7
WO 9
WO 6
WO 11
LO 25
WO 6
LAO 15
LO 18
10.3
558
BSCK TPN GPS 2
PN 7
WAX 12
LO 16
9.7
6.7
10.0
7.0
568
10.437
END WDFE
10.1
10.2
10.2
572
8.373
IE 18"HDPE
9.2
10.2
10.3
10.7
10.6
10.6
10.8
11.0
10.7
10.4
9.5
10.4
10.4 10.3
10.3
9.7
10.1
10.1
10.2
9.5
10.2
10.7
10.9
10.6
10.5
10.2
9.3
9.8
10.0 9.9
9.7
9.5
9.9
10.1
10.3
10.1
609
TRASH
10.0
10.4
10.3
10.1
9.5
9.9
10.1
10.510.410.410.410.5
10.3
10.5
10.5
10.7
10.4
10.4
10.2
10.5
10.6
10.1
9.9
10.0
636
9.990
WDFE
10.6
10.7
10.9
10.8
10.9
10.7
10.6
10.5
10.5
10.5
10.1
648
BSXK TPN 22
9.6
9.3
651
9.781
WDFE
9.8
9.9
10.1
10.1
10.1
10.0
9.9
9.8
9.8
9.9
10.7
10.9
11.1
11.1
11.0
10.9
10.2
9.9
9.8
9.8
10.0
9.9
9.8
10.0
10.3
10.1
10.4
10.5
11.1 11.0
11.311.4
11.4 11.2
11.712.2
12.4
12.1 12.0 11.6
11.311.711.9
11.5 11.2
10.8
698
YLD SGN
10.8
11.2
10.5
10.5
10.7
704
STOP SGN
705
10.091
WDFE
706
10.666
PDR 24" RCP
707
10.679
PDR 24" RCP
708
8.283
PDR 18" RCP
709
8.281
PDR 18" RCP
710
BSCK TPN 27
N43°23'37"E 336.64'
C1
S71°20'55"W 186.95'
C2
N16°23'26"W 103.88'
L1
L2L3
STEPS
STEPS
0.5' PLANTER
N:134964.16
E:2089609.50
N:134976.48
E:2089509.78
N:134731.86
E:2089278.50
10.9
10.6
8.7
10.1
10.1
10.2
11.3
11.3
11.3
11.4
11.5
11.4
10.9
11.2
11.9
11.6
11.4
11.2
11.6
11.9
11.1
11.2
11.1
11.1
10.8
10.6 10.9
10.2
10.6
10.6
10.4
10.6
11.0
10.8
9.8
10.2
11.110.7
11.0
11.1
10.8
10.2
11.4
11.5
11.2
11.2
10.7
10.9
10.9
11.1
11.2
11.2 10.8 10.7
11.0
11.0
10.8
11.0
11.1
11.2
12.3
11.4
12.4
12.1
12.1
12.1
12.1
11.4
11.4
10.7
13.1
12.1
13.1
12.1
12.2
11.9
11.9
12.3
10.9
10.9
10.9
11.2
11.3
11.311.4
11.0
10.410.6
9.6
9.6
11.4
11.0
11.4
11.5
11.7
11.6
11.7
12.2
12.3
11.7
11.9
12.5
12.3
12.1
11.8
12.2
11.8
11.8
11.7
12.5
12.1
12.4
12.3
12.1
12.212.1
12.1
12.2
12.2
12.7
11.9
11.8
11.7
11.7
12.5
12.6
12.3
12.0
11.7
13.2
13.3
13.1
10.5
9.6
10.2
12.1
12.6
TOP OF BANK
SLATE
SIDEWALK
LOADING/UNLOADING
DOCK
STEPS
4" CONDUIT
TRASH CAN
2' BENCH
WOOD
DECK
TREE DRIPLINE
LO 13-16-19
TREE DRIPLINE
LO 5-9-10-11-13-16-17
0.8' WALL
0.8' RETAINING WALL
FLAG POLE
TOP OF BANK
IE=8.73'
IE=6.14'
IE=5.99'
IE=5.80'
0.8' WALL
15" HDPE
IE=8.17'
18" RCP
(FLARED)
IE=6.18'
IE=6.15'
18" HDPE
IE=7.09'
24" RCP
(FLARED)
IE=6.29'
IE=6.17'
GAS GRILL
0.5' PLANTER
12.1
11
12
12
12
12
12
12
11
12
13
12
12
12
12
12
12
13
14
12
12
10
10
10
11
10
11
11
10
10
10
1011
11
10
11
11
11
10
11
11
10
9
8
10
8
9
10
9
10
7
8
9
11
S17°33'40"E 298.19'
11
CONCRETE
LANDING
L4
L5L6
C3L7
L8
L9
C4
L10 C5
L11
L12
LINE TABLE
LINE
L1
L2
L3
L4
L5
L6
L7
L8
L9
L10
L11
L12
LENGTH
56.67'
31.28'
40.45'
18.01'
89.95'
150.78'
15.47'
43.54'
7.30'
22.25'
151.23'
90.52'
BEARING
S72°15'20"W
S72°43'03"W
S73°36'34"W
N17°34'11"W
S70°45'38"W
N70°29'04"E
N59°00'42"E
N78°45'54"E
S11°14'06"E
N59°00'42"E
N70°29'04"E
N70°45'38"E
CURVE TABLE
CURVE
C1
C2
C3
C4
C5
LENGTH
110.10'
116.24'
17.12'
40.96'
20.21'
RADIUS
75.00'
74.00'
120.85'
235.74'
138.85'
TANGENT
67.66'
74.00'
8.57'
20.53'
10.12'
CHORD
100.48'
104.65'
17.10'
40.91'
20.20'
CHORD BEARING
S82°57'08"E
S61°23'26"E
S63°41'49"W
N64°57'35"E
S63°46'03"W
DELTA
084°06'49"
089°59'53"
008°06'57"
009°57'17"
008°20'28"
PN 14
PLM 12
PLM 12
PN 18PN 13
PN 16
CED 6
11.5
12.0
11.2
10.5
10.6
6.0
6.1
9.5
10.4
5.9
LA 8
PN 16
PLM 12
CED 7
PN 10
12.1
12.1
11.8
12.1
12.0
12.1
12.1
12.1
11.7
11.4
11.8
11.8
11.6
12.3
12.2
11.7
F
DW
7'-0"-WIDE FLAT CONCRETE
W/ T.B.D. BENCHES
TOTAL SLOPE AT 1:12 TO
BENCHES IS APPROX 1'-0" DROP
OR 17'-0" OF RAMP
EXTEND
CONCRETE
LANDSCAPE
CURB AS REQ'D
ADDITIONAL
ROOMS
716 SF
FOOD DELIVERIES
FORMER RAMP
FILLED IN
TO GRADE
PATTY'S
SENSORY
GARDEN -
SEE
LANDSCAPE
23 EXISTING PARKING SPACES ARE
AVAILABLE TO 10 FT STAFF, 3 PT STAFF &
6 VOLUNTEERS (AS WELL AS VISITORS)
ON A DAILY BASIS.
ONE RESERVED SPACE IS BEING ADDED
FOR USE BY THE FOOD DELIVERY DRIVER
FDC
PIV
FIRE HYDRANT
IS LOCATED
ON TRELLIS
COURT, < 500'
FROM BLDG.
FOOD DELIVERY
PARKING ONLY
SILT FENCE
SILT FENCE
SILT FENCE
4-YD DUMPSTER
IN SERVICE YARD
ON 6 IN. CONC.
PAD - SEE DETAILCONSTRUCTION
DUMPSTER
WASHOUT
BOLLARDS
CONSTRUCTION STAGING
AREA - CONTRACTOR TO
MAINTAIN SEDIMENT
CONTROL AS REQUIRED
SILT FENCE
LARGE-DONOR PLAQUE ON
STONE BASE T.B.D.
HYDRANT
LOCKED GATE W/
ELECTRIC BYPASS -
SEE LANDSCAPE
SILT FENCE
NON-PERMEABLE CONSTRUCTION:
CONSTRUCTED FOOTPRINT: 8,579 SF
LAGOON SURFACE: 25,908 SF
NON-PERMEABLE PAVING: 13,121 SF
OTHER NON-PERMEABLE: 8,331 SF
TOTAL NON-PERMEABLE: 55,939 SF
55,939 NON-PERM/103,852 (LOT) = 54%
SITE
7'-0"
RAMP
@1:12
LANDIN
G
NEW
CONC.14.2
10'-0"
RAMP
@1:12
CONNECTION
CONCRETE
SLOPES FROM 14.2 TO 14.1
EXIST.
CONC.14.1
FLAT CONCRETE
@ 12.7
DEMOLISH EXISTING
WALK
DEMOLISH EXISTING
WALK
13.4
FLAT
STEPS
FLAT
FLAT
HANDICAPSTALL
HANDICAPSTALL
S.1.2
Page 17 of 69
A R CH ITECT S
A R CH ITECT S
parkerdesigngrouparchitects
843 785 5171 POST OFFICE BOX 5010 HILTON HEAD ISLAND SC 29938
A facility upfit for:
Hilton Head Island, South Carolina
Memory MaƩers
REVISIONS DATE
DATE OF ISSUE:
SHEET
SGK
SCALE
DRAWN BY
CHECKED BY
JOB NO.
These documents & designs are
the property of Parker Design
Group|Architects & are not to
be used or reproduced there of or
for designs, working drawings,
or construction of buildings
without the written authorization
from the copyright owner
PDG|Architects 2025 copyright C
2546
@ 15 Trellis Court
FOR
FINAL
STATE REVIEW
A.1.0
AS-BUILT & DEMO
PLAN
7/27/2026
WTP
DPH PROJECT
#1016806
F
F
DW
ICE
DN
OFFICE
RECEPTION ENTRANCE 2CONFERENCE
LOBBY
OFFICE
LAYOUT AREA
REST
ROOM BREAK-2
OFFICE OFFICE OFFICE
MECH
MAIL/COPY
OFFICE
LIBRARY
BREAK
ROOM
LAYOUT
COUNTER 1
1 1
1
1 1
1
1
1
1
1
1
1 1 1 1
1
1
1
1 1 1
1
2
2
2
2
2
2
2
3 3
3
3
33
3
3
3
3
33
3 3
3
3
3
1
2
3
3
4
4
4
4
1
2
6 6
11
1
3
3
3
3
OFFICE
9'-11" BEAD BOARD
PAINTED BEAM CEILING
REST RM
4
9
8'-11" GYP. CEILING
9
10
11'-3" GYPSUM
BOARD CEILING
DISPLAY AREA
13'-2 OPEN DECK
12'-8" OPEN DECK
12'-3" OPEN DECK 12'-3" OPEN DECK9'-8" ACT CEILING
12 13
1212
9'-8" ACT CEILING
OFFICE
9'-8" ACT CEILING
12'-5" OPEN DECK
9'-11" GYP. CEILING
W/STAINED BEAMS 9'-11" GYP. CEILING
9'-11" GYP. CEILING
W/STAINED BEAMS
10'-11" GYP. CEILING
11'-2" GYP. CEILING
REAL BRICK WALL
STAINED WAINSCOT
& GRASSCLOTH GYPSUM
STAINED WAINSCOT
2
9
10
2
1 1
3
SERVER
CORR
9'-11" GYP.
CEILING 9'-11" GYP.
CEILING
STOR STOR
DISPLAY
AREA
8'-11" GYP. CEILING
REST RM
CERAMIC TILE
1
1
8'-11" GYP.
CEILING
CPT
14
COPIER
SPACE
CABINETS
& COUNTER
15
CABINETS &
COUNTER REMAIN
10
3
3
3
5
16
17
RELOCATE
FIRE EXTING.
CABINET
HERE
18
18
19
1
1
1
1
1
1
20 21
1
1
EXISTING
ARCHED
SOFFIT
22
22
22
22
CORR
CORR
CORR
22
22 2222
22
22
22
22
22
2222 22
22
22
22 22 22
22
2222
11
7
23
24
ELEC.
10
25
25
9
10 REUSE IN BRAIN
GAME ROOM 104
REUSE THE "HUTCH"
ABOVE THE COUNTER
TO THE COUNTER ON
BACK WALL OF
RECEPTIONIST'S
OFFICE #136
REUSE 4 WOOD FILE
CABINETS TO HOLD
NEW WORK LEDGE
IN FLEX ROOM 128
REUSE 4 UPPER &
LOWER WHITE
CABINETS AT SPACE
BY ALCOVE 132
3
4
LAYOUT
COUNTER
3
3
3 3
3
3
3
3
3
25
25
25
25
25
25 254
25
3
SALVAGE AND STORE
WHITE DOOR CABINETS
FOR T.B.D. LOCATION
3
1
1212
26
6
A.5.1
7
4
5
6
8
1
2
3
KEYED DEMO NOTES
9
DEMOLISH WALL
DEMOLISH DOOR, FRAME, & EXT. EGRESS LIGHT - SEE DR. SCHEDULE RE: SALVAGE/REUSE
DEMO MOST "DASHED ITEMS" BUT SEE PLANS FOR REUSED ITEMS NOTES
10
DEMOLISH PLUMBING FIXTURE AND OR STONE COPUNTERTOP
REMOVE APPLIANCE - SALVAGE FOR OWNER IF APPLICABLE
DEMOLISH EXTERIOR STEPS AND/OR RAILINGS - SEE DEMO & FLOOR PLANS
DEMOLISH WATER HEATER, MOP SINK, & CAP PLUMBING
RETAIN WALL & FLOOR FINISHES TO GREATEST EXTENT POSSIBLE
RETAIN CEILING TREATMENT TO GREATEST EXTENT POSSIBLE. GRASSCLOTH MAY BE REMOVED.
PROTECT & RETAIN EXISTING WALL UNIT
11 REMOVE HVAC UNIT AND RELOCATE - SEE NEW FLOOR PLAN
12 DEMOLISH EXISTING CEILING TILE & GRID
13 REMOVE EXISTING CERAMIC TILE FLOOR
14 DEMO POCKET DR. & CREATE WD. CASED OPENING. TRIM CROWN FOR NEW WALL CONSTRUCTION
15 REMOVE DOOR & FRAME - REINSTALL IN ADJACENT ALCOVE - SEE NEW PLAN
16 REMOVE FIRE EXSTINGUISHER CABINET - SALVAGE FOR POTENTIAL REUSE
17 REMOVE FIRE EXSTINGUISHER CABINET & RELOCATE AS SHOWN
18 DEMOLISH EXTERIOR SIDEWALK AS NOTED
19 MODIFY CABINETS TO (1) 36" SECTION TO ALLOW A 53"-LONG COPIER.
20 REMOVE CEILING FAN AND SALVAGE FOR USE IN PROGRAM RM 105
21 DEMOLISH TRACK LIGHTING FEATURE
22 DEMOLISH FLOORING IN THIS ROOM AND PREP FOR NEW FLOOR FINISH
23 RELOCATE WATER SHUT-OFF INTO LOCKED METAL CABINET ON WALL
24 RELOCATE DOWNSPOUT AS REQUIRED TO ALLOW SPRINKLER RISER LEAN-TO
25 DEMOLISH LIGHT FIXTURE
26 DEMOLISH WINDOW & PREP FOR REPLACMENT CASED DOOR OPENING
N
SCALE: 1/8" = 1'-0"
1AS-BUILT & DEMO PLAN
A.1.0
PLAN
DEMO NOTE #3
CLARIFIED 6-25-26
Page 18 of 69
A R CH ITECT S
A R CH ITECT S
parkerdesigngrouparchitects
843 785 5171 POST OFFICE BOX 5010 HILTON HEAD ISLAND SC 29938
A facility upfit for:
Hilton Head Island, South Carolina
Memory MaƩers
REVISIONS DATE
DATE OF ISSUE:
SHEET
SGK
SCALE
DRAWN BY
CHECKED BY
JOB NO.
These documents & designs are
the property of Parker Design
Group|Architects & are not to
be used or reproduced there of or
for designs, working drawings,
or construction of buildings
without the written authorization
from the copyright owner
PDG|Architects 2025 copyright C
2546
@ 15 Trellis Court
FOR
FINAL
STATE REVIEW
A.1.1
FIRST FLOOR PLAN &
WALL TYPES
7/27/2026
WTP
DPH PROJECT
#1016806
101
102
103104
106
108
109A 109B
111
112
113
114
116
118
117
123A
123B 123C
123D
125
128
129
130
135
138
105
127
141
F
DW
7
A.3.0
7
A.3.0
2
A.3.0
3
A.3.1
11
A.5.0
6'-6"
8'-6"2'-0"
4'-8" 4'-1"
12'-0 1/2" 11'-0 1/2" 8'-11 1/2" 8'-11" 5'-9"
2'-11 1/2" 5'-9"
24'-0"
11'-11" 7'-8"
5'-6" 24'-0"
11'-3 3/4"
5'-6" 24'-0"
9'-0"
12'-4"
3" 1'-6"3" 1'-4"
1'-4"
1'-6"
3"1'-6" 1'-6"
24'-3" CANOPY
29'-6" CANOPY
9'-7"
CANOPY 3"
15'-4"
1'-5"
7'-1 1/2" 6'-11"
7'-11" 11'-7"
3 1/2"
2'-7"
6'-8"
6'-8"
3'-9 1/2" 3'-10" 7'-1"
8" 7'-9 1/2" 4 1/2"
4'-3 1/2"
3-5"
CLEAR
4'-0"
RAMP
8'-1"
3'-0"
3'-5 1/2"
11'-6"
16'-0"
7'-3"
5'-0"
5'-0" 8'-0"
8'-8" 8'-8" 8'-8"
6 7/16"
7'-4" 7'-4" 7'-4"
26'-4" EDGE OF SECOND CANOPY
8'-8"
TO OTHER EDGE
17'-10 1/2"
ICE
DN
BUFFET
1:12 RAMP DOWN
TO SENSORY GARDEN
OFFICE 129
OFFICE 130
FLEX WORKSPACE
128
LAUNDRY
& JAN
127
OFFICE
135
CLASSROOM
123
23'-0" X 22'-0"
STAFF
COFFEE
121
GUEST &
PATIENT
R.R. 126
STAFF
R.R. ADA
120
ELEC.
ELEC.
BULLETIN BOARD
PASS-
THRU
SERVING
COUNTERSTOR.
MUSIC ROOM
116
20'-0" X 15'-7"
GARDEN
ENTRY
FENCE - SEE LANDSCAPE
GENERAL PROGRAM AREA
105
42'-0" X 26'-4"
DAYCARE
ENTRANCE
101
15'-2" X 19'-4"
W.I.C.
PROGRAM
STORAGE
106
OFFICE
138
BRAIN GAME ROOM
104
22'-4" X 15'-2"
LOCKED
MEDS. CAB.
LOCKED
FIRST AID
ETC. RESTING RM
118
DOOR BETWEEN THE TWO
"ZONES" OF THE BUIDLING
CABINETS
ANTE
ROOM
125
ANTE
ROOM
113
STOR.
FROM DEDICATED
CATERING PARKING
CONFERENCE
133
R.R.
102
19'-4" X 19'-1"
4'-0"x8'-0"
CASED
OPENING
5'-6" x 8'-0"
CASED OPENING
ALIGN WALL AT NORTH
EDGE OF EXIS. BEAM
EXIST.
CASED
OPENING
EMPLOYEE
COATS STOR
DISPLAY
AREA
RECEPTIONIST
136
ALCOVE
139
ALCOVE
132
HOSPITALITY
ANTE
ROOM
115
STACKED
W/D
DESK &
DISPLAY
FOUR SEASONS
ROOM 108
COPIER
BY
OTHERS
BENCHBENCH
STACKED LOCKERS
TBD, TYPICAL
DW
NEW
REFRIG
HEATED
CABINET
PANTRY
CATERING STYLE
KITCHEN 109
17'-0" X 22'-0"
SUPPLIES
CHECK-IN
COMPUTER ON
MOBILE STAND
TV ON WALL
ICE
SERVER
CLOSET
STORAGE T.B.D.
REUSE
SALVAGED
UPPER &
LOWER WHITE
CABINETS W/
NEW SINK &
COUNTER
REUSED WOOD
FILE CABINETS
WITH SLAB ON
TOP PER INTERIORS
HANDRAILS TYPICAL
IN CORRIDORS
HANDRAILS TYPICAL
IN CORRIDORS
CL
COVERED
PORCH
EXISTING
CONCRETE
MATCH
EXSITING
LEVEL
B
B
A
A
A
A
A A
C
A
AA
A
B
B
A
A
A
A
A
A
A
A
B
A
A A A A
C
A
A
A
A A
A A
BUILDING
SECTION
BUILDING
SECTION
PATTY'S
SENSORY
GARDEN -
SEE LANDSCAPING
R.R.
103
BREEZEWAY
107
ANTE
ROOM
110
CORR.
119
CORR.
117
CORR.
122
CORR.
124
CORR.
137
LOBBY
140
RELOCATED
FRENCH DRS.
CASED OPENING
6'-0"x8'-0"
CAP END OF
ACCOUSTIC
FEATURE
WITH GYP BD.
PER
INTERIORS
CAP END OF
ACCOUSTIC
FEATURE
WITH GYP BD.
PER
INTERIORS
REUSE
SALVAGED
"HUTCH" HERE,
ON COUNTER
1
A.5.0
5
A.5.0
8
A.5.0
ADD 3 GRAB BARS
TO EXIST RESTROOM
CL
ADD VERTICAL
GRAB BAR
BB B B
B
B
B
B
BBBB
C
A
A
NEW
FREEZ
RELOCATED HVAC UNITS ON
CONCRETE PAD +/- 12'-0 MSL
EXISTING METERS
EXISTING
HVAC
UNIT
NEW
ROOF
LADDER
SPRINKLER
LEAN-TO 141
A
RISERS
NEW STAIR
GATE WITH
LATCH
BUILDING SETBACK
LINE
A
C RAILING ON WALL
CABLE RAILING SYSTEM -
SEE EXT. ELEVATION
REUSE SALVAGED
WALL UNIT (WITH
6 LOWER DOORS)
HERE
ELECTRIC
DOOR
OPENER
ELECTRIC DOOR
OPENER ON POST
ALIGN WALL AT NORTH
EDGE OF EXIS. BEAM
REPLACE
FIXTURES
NEW MOP
SINK W/
FRP 3'-0"H
ON WALLS
SIGNAL SYSTEM
FOR CALL BUTTONS;
CAMERA DISPLAYS
A
WH
ART ROOM
111
7'-0" H FENCE PER OWNER.
SEE EXTERIOR ELEVATIONS
NEW HVAC UNITS
ON CONCRETE PAD
+/- 12'-0 MSL
FENCE & GATE W/
ELECTRONIC BYPASS -
SEE LANDSCAPE
LOCKED
WALL
CABINET
FOR
CHEMICALS
PULL
CORD
PULL
CORD
REPLACE
RANGE
HANDICAP
SPACE
4
A.5.1
(4) 5 1/2" RISERS
(3) 18" TREADS
1
A.5.1
CONCRETE
BOLLARD
CONCRETE
BOLLARD
CANOPY
CANOPY
CASED OPENING
7'-6"x +/-9'-0"SECRETARY DESK
SELECTED BY
INTERIORS
109D
139
126
119A
119B
120A
120B
109C
10'-7" 10'-4 1/2" 5'-3 1/2" 9'-1 3/4" 13'-5"
9'-2"
CANOPY
5'-0"
OFFICE
131
OFFICE
134
R.R.
114
19'-4" X 19'-4"
HANDRAILS TYPICAL
IN CORRIDORS
7''-0" RAMP
@1:12
LANDING
13.4
NEW
CONC.
14.2
10'-0"
RAMP
@1:12
CONNECTION CONCRETE
SLOPES FROM 14.2 TO 14.1
FLAT CONCRETE @ 12.8
BENCH BENCH
5'-0"X6'-0"
FLAT
12.7
BENCH
B
A
CANOPIED
WALKWAYS
MIMIC THE EXISTING
CONCRETE BORDERS
ON NEW CONCRETE
WALKS & RAMPS, TYP.
EXISTING PLANTER -
NO NEW WORK
EXTEND
LANDSCAPE
CURB AS
REQUIRED
DONOR
PLAQUE TBD
C.J.C.J.
C.J.
FLAT
CONCRETE
@ 12.8
CANOPY LIGHT,
TYP. - SEE ELEC.
TYPE INT. WALLB
1/2" GYPSUM BOARD
TYPICAL
TYP. 2X4 STUDS @
16".O.C.
WALL KEY AND DETAILS
TYPE INT. WALLA
1/2" GYPSUM BOARD
TYPICAL
TYP. 2X4 STUDS @
16".O.C.
1/2" GYPSUM BOARD
ON BOTTOM OF JOISTS
-OR- OPEN - SEE RCP
3" MINERAL WOOL
SOUND INSULATION
TYPE INT. WALLC
1/2" GYPSUM BOARD
TYPICAL
TYP. 2X6 STUDS @
16".O.C.
3" MIN. MINERAL WOOL
SOUND INSULATION
1/2" GYPSUM BOARD
ON BOTTOM OF JOISTS
-OR- OPEN - SEE RCP
1/2" GYPSUM BOARD
ON BOTTOM OF JOISTS
-OR- OPEN - SEE RCP
1,104
SF DAY CARE PROGRAM SPACES
GENERAL PROGRAM SPACE 1,134
MUSIC, ART, & BRAIN GAMES
576 DINING/SOCIALIZATION
2,814
SF DAY CARE SUPPORT SPACES
RESTING ROOM 210
REST ROOMS & SHOWER 281
CATERING KITCHEN 418
STORAGE 88
1,061
SQR. FOOTAGE USE
SF BUSINESS SPACES
552
SF BUSINESS SPACES
CLASSROOM
1,324
1,734
410
OFFICES
CONFERENCE
JANITOR/LAUNDRY 64
SF BUSINESS SUPPORT
249 COFFEE / REST RM / IT
STORAGE
SPRINKLER RM
101
35
385
SF CIRCULATION
DAYCARE CIRCULATION 828
BUSINESS CIRCULATION 1,317
2,145
SF TOTALS
DAYCARE TOTAL SF 4,564
BUSINESS TOTAL SF 4,015
8,579 BUILDING TOTAL SF
N
SCALE: 1/8" = 1'-0"
1PROPOSED 1ST FLOOR PLAN
A.1.1
PLAN
Page 19 of 69
A R CH ITECT S
A R CH ITECT S
parkerdesigngrouparchitects
843 785 5171 POST OFFICE BOX 5010 HILTON HEAD ISLAND SC 29938
A facility upfit for:
Hilton Head Island, South Carolina
Memory MaƩers
REVISIONS DATE
DATE OF ISSUE:
SHEET
SGK
SCALE
DRAWN BY
CHECKED BY
JOB NO.
These documents & designs are
the property of Parker Design
Group|Architects & are not to
be used or reproduced there of or
for designs, working drawings,
or construction of buildings
without the written authorization
from the copyright owner
PDG|Architects 2025 copyright C
2546
@ 15 Trellis Court
FOR
FINAL
STATE REVIEW
A.1.2
REFLECTED CEILING
PLAN
7/27/2026
WTP
DPH PROJECT
#1016806
GUEST &
SENIOR
R.R. ADA
18'-8"
BUFFET
LAUNDRY
& JAN
OFFICE
CLASSROOM
STAFF
COFFEE
STAFF
R.R. ADA
STOR.
MUSIC ROOM
ART ROOM
GENERAL PROGRAM AREA
W.I.C.
PROGRAM
STORAGEOFFICE
BRAIN GAME ROOM
RESTING RM
ANTE
ROOM
ANTE
ROOM
STOR.
CONFERENCE
ENTRANCE 1
RECEPTIONIST
FOUR SEASONS
ROOM
COPIER
BY
OTHERS
CATERING STYLE
KITCHEN
SUPPLIES
SERVER
CLOSET
CL
COVERED
PORCH
FLEX
OFFICE
GYP. BD. @
15'-10" AFF
OPEN TO
ROOF DECK
OPEN TO
ROOF DECK
GYP. BD. @ 8'-6" AFF
GYP. BD.
@ 9'-8"
SALVAGE
ACT @
9'-8" AFF
SALVAGE
ACT @
9'-8" AFF
SALVAGE ACT @
9'-8" AFF
SALVAGE ACT @
9'-8" AFF
GYP. BD. @ 10'-0" AFF ACT @ 10'-0" AFF
PATCH
EXISTING
EXISTING EXISTING
EXISTING CEILING
TO REMAIN
EXISTING
CEILING TO
REMAIN
BEVERAGES STOR.
EXISTING EXISTING
DISPLAY
AREA
ALCOVE
ACT-1 @
11'-0" AFF
GYP. BD. @
9'-8" AFF
DAYCARE
ENTRANCE
SALVAGE
EXISTING
CEILING
TO REMAIN
ARMSTRONG "KITCHEN ZONE" ACT
@ 8'-0" AFF
ACT-1 @
8'-6" AFF
GYP. BD. HEADER AT 9'-11" AFF
ANTE
ROOM
ANTE
ROOM
SALVAGE ACT
@ 9'-8" AFF
WP
OPEN TO
ROOF DECK
STOR.
OPEN TO
ROOF DECK
EXISTING CEILING
TO REMAIN
OFFICE
EXIS. SMALL
DIRECTIONAL
CAN LIGHTS
EXIS. SMALL
DIRECTIONAL
CAN LIGHTS
OFFICE
OFFICE
EXISTING LIGHTS &
CEILING TO REMAIN
EXISTING LIGHTS &
CEILING TO REMAIN
EXISTING CEILING
TO REMAIN
EXISTING CEILING
TO REMAIN
GYP. BD. @
9'-8" AFF
EF
EF
EF
EF
EF
EF
EF
S/C
D
S/C
D
FEC
EXIT SIGN
EXIT
SIGN
EXIT/
EMER
SIGN
EXIT/
EMER
SIGN
EXIT/
EMER
SIGN
FEC
FEC
FEC
EXIT/
EMER
SIGN
EXIT/
EMER
SIGN
EXIT/
EMER
SIGN
FEC
S/C
D
S/C
D
S/C
D
S/C
D
S/C
D
S/C
D
S/C
D
S/C
D
S/C
D
S/C
D
S/C
D
S/C
D S/C
D
S/C
D
EXISTING CEILING TO REMAIN
EXISTING CEILING TO REMAIN
EXISTING CEILING TO REMAIN
EXISTING CEILING TO REMAIN
EXISTING CEILING TO REMAIN
EXISTING
CEILING
TO REMAIN
EXIT/
EMER
SIGN
EXIT/
EMER
SIGN
EXIT/
EMER
SIGN
EXISTING
CEILING
TO REMAIN
EXISTING
CEILING
TO REMAIN
CL
NEW GYP.
BD. CEILING
9'-8" AFF
EXTERIOR
EXIT/EMERG.
LIGHT
EXTERIOR
EXIT/EMERG.
LIGHT
EXTERIOR
EXIT/EMERG.
LIGHT
ALCOVE
EXISTING
CEILING
TO REMAIN
EXIT/
EMER
SIGN
GYP. BD.
@ 9'-8"
GYP. BD.
@ 9'-8"
ELEC.
ELEC.
EXIT/
EMER
SIGN
EMER
LIGHT
EMER
LIGHT
EMER
LIGHT
EXIT/
EMER
SIGN
EXIT/
EMER
SIGN
EXISTING CEILING
TO REMAIN
WALL-MOUNTED FIRE-ALARM
ANNUCIATOR PANEL
NEW
EXTERIOR
CAN
LIGHT
NEW FLOOD LIGHT IN EXIS.
JUNCTION BOX -
6'-8" AFF MIN. (A.D.A.)
EXTERIOR
EXIT/EMERG.
LIGHT
NEW FLOOD
LIGHT IN EXIS.
JUNCTION BOX
NEW STELLA OUTDOOR
FLOOD LIGHT ON SAME
CIRCUIT AS ADJACENT
FLOOD LIGHTS
OFFICE
PASS-
THRU
SERVING
COUNTER
RESTROOM
RESTROOM
RESTROOM
RESTROOM
SYMBOL KEY
3" x 48" PENDENT-MOUNTED
LED LIGHT
WALL SCONCE
PENDANT
CAN LIGHT
24"x24" LED LIGHT FIXTURE
CEILING FAN
DEMOLISHED LIGHT (DASHED)
EMERGENCY LIGHT
EXIT SIGN
EMERGENCY & EXIT LIGHT
TRACK LIGHTING
SUPPLY DIFFUSER
RETURN AIR GRILLE
S/C
D
EXHAUST FAN
COMBINATION SMOKE/
CARBON MONOXIDE DETECTOR
EXTERIOR FLOOD LIGHT
SELECTED BY ARCHITECT
EXTERIOR CANOPY LIGHT
SELECTED BY ARCHITECT
GENERAL CEILING NOTES
1. THE SPRINKLER SYSTEM AND FIRE ALARM SYSTEM WILL BE
DESIGNED BY OTHERS, UTILIZING INTERNATIONAL FIRE CODE
2021 W/ SOUTH CAROLINA AMENDMENTS, AFTER STATE &
LOCAL FINAL APPROVAL OF PLANS.
2. THE STATE OF CAROLINA AND THE TOWN OF HILTON HEAD
ISLAND RESERVE THE RIGHT TO REQUIRE CHANGES TO THE
SPRINKLER SYSTEM AND FIRE ALARM SYSTEM DESIGNS.
3. THE MEMORY MATTER FACILITY SHALL HAVE AN ALARM
SYSTEM THAT INCLUDES SMOKE DETECTION IN ALL MAIN
AREAS, AND PULL STATIONS THROUGHOUT THE BUILDING, ALL
SUPERVISED BY THE FIRE ALARM SYSTEM.
4. MEMORY MATTERS SHALL ENSURE THE ALARM SYSTEM IS
ARRANGED TO TRANSMIT AN ALARM AUTOMATICALLY TO A
THIRD PARTY BY AN APPROVED METHOD.
5. MEMORY MATTERS SHALL ENSURE THE ALARM SYSTEM
NOTIFIES BY AUDIBLE AND VISUAL ALARM ALL AREAS AND
FLOORS OF THE BUILDING.
6. MEMORY MATTERS SHALL ENSURE THE ALARM SYSTEM SHUTS
DOWN CENTRAL RECIRCULATING SYSTEMS AND OUTSIDE AIR
UNITS THAT SERVE THE AREA(S) OF ALARM ORIGINATION, AS
A MINIMUM.
7. THE FIRE ALARM SYSTEM SHALL ENSURE THAT NO SMOKE
DETECTOR IS LESS THAN 3'-0" AWAY FROM HVAC SUPPLY &
RETURN VENTS OR THE FAN-TIPS OF A CEILING FAN.
SCALE: 1/8" = 1'-0"
1REFLECTED CEILING PLAN
A.1.2
Page 20 of 69
A R CH ITECT S
A R CH ITECT S
parkerdesigngrouparchitects
843 785 5171 POST OFFICE BOX 5010 HILTON HEAD ISLAND SC 29938
A facility upfit for:
Hilton Head Island, South Carolina
Memory MaƩers
REVISIONS DATE
DATE OF ISSUE:
SHEET
SGK
SCALE
DRAWN BY
CHECKED BY
JOB NO.
These documents & designs are
the property of Parker Design
Group|Architects & are not to
be used or reproduced there of or
for designs, working drawings,
or construction of buildings
without the written authorization
from the copyright owner
PDG|Architects 2025 copyright C
2546
@ 15 Trellis Court
FOR
FINAL
STATE REVIEW
A.1.3
SCHEDULES & DOOR/
WINDOW TYPES
7/27/2026
WTP
DPH PROJECT
#1016806
8'-0"
SEE SCHED
8'-0"
6'-0"
8'-0"
SEE SCHED
5'-0"
3'-0"
8'-0"
7'-0"
SEE SCHED
HARDWARE SCHEDULE
MARK REMARKSMFG. & STYLETYPE
1
MFG. NUMBER
NOTES: 1. SUBMIT FULL HARDWARE SCHEDULE FOR REVIEW
2. ALL FINISHES TO MATCH EXISTING COLOR HARDWARE
3. ALL EXISTING KNOBS REPLACED WITH LEVERS
DOOR & FRAME ELEVATION KEYS
TYPE 3TYPE 1
2 SCHLAGE LATITUDE
FB50LAT622
4 DSP-3
SCHLAGE LATITUDESCHLAGE LATITUDE
SCHLAGE LATITUDE
PASSAGE LEVER
DOUBLE-SWING
3
ELIASON EASY SWING HINGE
101
102
FRAME
DOOR
Material /
Finish Type REMARKSSizeMARK
FIRE
RATING
TW H
DOOR & FRAME SCHEDULE
NA
HARD-
WARE
MARK
NA
NA
EXIST
NA
103
NA
WOOD
NA
NA
NA
104
105
112
114
118
119A
125
NA
EXIST NA
NA
NA
NA
NA
NA
NA
ADD AUTOMATIC OPENERS TO DOORS VIA EXTERIOR BUTTON ON
PEDESTAL AND VIA INTERIOR WALL BUTTON
1
EXISTEXIST/PAINT 5
1
1
REPLACE LEVER AND DEADBOLT
8'-0" 1 3/4"
8'-0"3'-0" 1 3/4"
8'-0"3'-0" 1 3/4"
8'-0"2'-8" 1 3/4"
8'-0"3'-0" 1 3/4"
8'-0"3'-0" 1 3/4"
1
EXIST EXIST EXIST
EXIST EXIST EXIST
WOOD NA
WOOD NA
WOOD NA
WOOD NA
NA
WOOD NA1
WOOD NA1
WOOD NA1
WOOD NA1
NA
6
2 DUMMY LEVERS W/ ROLLER CATCH AT TOP
EXIST/PAINT EXIST EXIST
8'-0"3'-0" 1 3/4"
2-PANEL SMOOTH
TO MATCH EXISTING
FULL-LITE SMOOTH
TO MATCH EXISTING
1WOOD/PAINT
PRIVACY LEVER LOCK FB51LAT622
F10LAT622
ENTRY LEVER LOCK W/ DEADBOLT
NO HANDLE HARDWARE
WOOD18'-0"3'-0" 1 3/4" 1WOOD/PAINT
WOOD28'-0" 1 3/4" 2WOOD/PAINT3'-0"
TYPE 2
FULL-LITE SMOOTH
TO MATCH EXISTING
WOOD8'-0" 1 3/4" 3WOOD/PAINT2X(3'-0")
PUSH & PULLS W/ CLOSERS
3
106 WOOD28'-0" 1 3/4" 2WOOD/PAINT3'-0"
108 WOOD28'-0" 1 3/4" 2WOOD/PAINT3'-0"
109A
109B
109C
8'-0"3'-0"
8'-0"3'-0"
STAINLESS STEEL
STAINLESS STEEL
TYPE 4
ELIASON DSP-3
STAINLESS STEEL
16 GA. DOOR W/
EASY SWING HINGE
WOOD CASED OPENING FRAME16 GA.
16 GA.
4
4
4
4
WOOD
WOOD WOOD CASED OPENING FRAME
DUMMY LEVER F170LAT622 ROLLER CATCHES AT TOP SCHLAGE LATITUDE
5
6
111 WOOD28'-0" 1 3/4" 2WOOD/PAINT3'-0"
NAWOOD8'-0"3'-0" 1 3/4" 1WOOD/PAINT
NAWOOD8'-0"3'-0" 1 3/4" 1WOOD/PAINT
116 NAWOOD28'-0" 1 3/4" 2WOOD/PAINT3'-0"
117 WOOD28'-0" 1 3/4" 2WOOD/PAINT3'-0"
WOOD28'-0" 1 3/4" 2WOOD/PAINT3'-0"
WOOD18'-0" 1 3/4" 2WOOD/PAINT3'-0"
123A WOOD28'-0" 1 3/4" 2WOOD/PAINT3'-0"
123B
123C
123D 22WOOD/PAINT
2X(1'-8")
2X(1'-8")
8'-0" 1 3/4"
WOOD/PAINT
WOOD/PAINT 1 WOOD6
2 DUMMY LEVERS W/ ROLLER CATCH AT TOP
22WOOD/PAINT
126 WOOD18'-0"3'-0" 1 3/4" 1WOOD/PAINT
127 2WOOD/PAINT
8'-0"3'-0" 1 3/4"128 WOOD12WOOD/PAINT
129
130 WOOD/PAINT 2
135 WOOD/PAINT 2
138
139 RELOCATED ADJACENT FR. DOOR PAIR INTO REDUCED-WIDTH FRAME
W/4 DUMMY LEVERS W/ ROLLER CATCH AT TOP EXISTEXIST
2X(2'-0") EXIST EXIST EXIST 1 WOOD NA
119B EXIST EXISTEXISTEXIST EXIST EXIST/PAINT 4 DUMMY LEVERS REPLACE KNOBS NA
1
120A EXIST EXISTEXISTEXIST EXIST NA
120B EXIST EXISTEXISTEXIST EXIST NA
EXIST/PAINT
EXIST/PAINT
2
2
6
PRIVACY LEVERS REPLACE KNOBS
PRIVACY LEVERS REPLACE KNOBS
PRIVACY LEVERS REPLACE KNOBS ON REPURPOSED DOOR
PRIVACY LEVERS REPLACE KNOBS ON REPURPOSED DOOREXIST EXISTEXIST EXIST EXIST/PAINT
EXIST EXISTEXIST EXIST EXIST/PAINT
TYPE 5
INSULATED METAL
DOOR
141 8'-0" 1 3/4" METAL NAMETAL/PAINT 15
NA109D 7'-0"3'-0" WOOD1 3/4" WOOD/PAINT 1 2
2X(3'-0")
FINISH SCHEDULE
Base HeightFinishMaterialFinishMaterialMaterial
WALLFLOOR CEILINGROOM NAME
PT-1DAYCARE ENTRANCE 11'-3"EXIST/ MATCH EXISTING PT-3
NOTES:
U.N.O. TYPICAL WALL BASE IS PAINT-GRADE 1X6 W/NOSING ON TOP TO MATCH EXISTING
SHEET VINYL W/ COVED EDGES AS SELECTED BY INTERIOR DESIGNER
LVP: CORETEC LVP AS SELECTED BY INTERIOR DESIGNER
T-1: WHITE WATERCOLOR SUBWAY 3X12 TILE, BF CERAMICS, PLACE FROM FLOOR UP TO
4'-0 AFF W/ GROUT AS SELECTED BY INTERIOR DESIGNER
PT-1: 2 COATS MINIMUM, SHERWIN WILLIAMS SW7008 ALABASTER, EGGSHELL
PT-2: 2 COATS MINIMUM, SHERWIN WILLIAMS SW7008 ALABASTER, SATIN
PT-3: 2 COATS MINIMUM, SHERWIN WILLIAMS SW7008 ALABASTER, FLAT
PT-4: 2 COATS MINIMUM, SHERWIN WILLIAMS SW6533 MILD BLUE, EGGSHELL
PT-5: 2 COATS MINIMUM, SHERWIN WILLIAMS SW6204 SEA SALT, EGGSHELL
PT-6: 2 COATS MINIMUM, SHERWIN WILLIAMS SW7029 AGREEABLE GRAY, EGGSHELL
PT-7: 2 COATS MINIMUM, SHERWIN WILLIAMS SW6246 NORTH STAR, EGGSHELL
PT-8: 2 COATS MINIMUM, SHERWIN WILLIAMS SW6247 KRYPTON, EGGSHELL
PT-9: 2 COATS MINIMUM, SHERWIN WILLAIMS SW6520 HONEST BLUE, FLAT
SHERWIN WILLIAMS PRIMER ON UNFINISHED WOOD AND UNFINISHED GYPSUM BOARD
SHEET VINYL: TARKETT IQ OPTIMA WITH COVED EDGES AND HEAT-WELDED SEAMS
ROOM
#
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
RESTROOM
BRAIN GAMES
WALK-IN STORAGE
BREEZEWAY
FOUR SEASONS
CATERING KITCHEN
ART ROOM
OFFICE
PT-4 / T-1 9'-0"GYP. BD. PT-3GYP. BD.
PT-3
PT-5 11'-0"MFR
PT-1
9'-8"
PT-9
EXIS ACTPT-1
VARIES
PT-1 10'-0"PT-3
PT-6 15'-10"PT-3
PT-2 8'-0"
"KITCHEN-ZONE"
ACT MFR.
PT-1
PT-3
PT-1 9'-8"PT-3
PT-3
PT-3
PT-3
PT-3
PT-3
PT-9
PT-1
PT-7
PT-7
PT-1
PT-7
PT-1
PT-1
PT-1
LVP
LVP
LVP
LVP
LVP
SHEET VINYL COVED VINYL
LVP
LVP
6"-HIGH T-1
LVP
LVP
LVP
LVP
LVP
LVP
LVP
LVP EXIST/GYP.BD.
RESTROOM GYP. BD.GYP. BD.6"-HIGH T-1 9'-0"
EXIST/ MATCH EXIST/GYP.BD.
EXIST/ MATCH EXIST/GYP.BD.
GYP.BD.
GENERAL PROGRAM
EXISTING
GYP BD
TYPICAL GYP.BD. GYP BD
EXIST/GYP.BD.
LVP
EXIST/GYP.BD.
EXIST/OPEN
ACT-1
EXIST/GYP.BD.
TYPICAL
EXIST/ MATCH
EXIST/ MATCH EXIST/OPEN VARIES
8'-6"ACT-1ANTE ROOM TYPICAL GYP.BD.
8'-6"GYP. BD. PT-3GYP. BD.6"-HIGH T-1RESTROOM
9'-8"GYP. BD. PT-3GYP. BD.6"-HIGH T-1RESTROOM
ANTE ROOM TYPICAL EXIST/GYP.BD. GYP. BD.
ANTE ROOM TYPICAL EXIST/GYP.BD. GYP. BD. 9'-8"
MUSIC ROOM EXIST/ MATCH EXIST/GYP.BD. SALVAGE ACT-1 9'-8"
CORRIDOR TYPICAL EXIST/GYP.BD. SALVAGE ACT-1 9'-8"
SALVAGE ACT-1 9'-8"
MFR.
MFR.
MFR.
MFR.RESTING ROOM EXIST/ MATCH EXIST/GYP.BD.
CORRIDOR PT-1LVP EXIST/ MATCH EXIST/GYP.BD. 8'-11"EXIS ACTEXISTING
RESTROOM EXISTING EXISTINGGYP. BD.6"-HIGH T-1
STAFF COFFEE EXIST/ MATCH EXIST/GYP.BD. EXISTING EXISTING
CORRIDOR EXIST/ MATCH EXIST/GYP.BD. EXISTING EXISTING
CLASSROOM EXIST/ MATCH EXIST/GYP.BD. EXISTING EXISTING
EXIS ACT
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
PT-1LVPCORRIDOR EXIST/ MATCH EXIST/GYP.BD. EXISTING EXISTINGEXIS ACT
PT-1LVPANTE ROOM EXIST/GYP.BD.EXIST/ MATCH EXISTINGEXIS ACT
EXIST/GYP.BD.RESTROOM 6"-HIGH T-1 PT-3EXISTING EXISTING
JANITOR/'LAUNDRY PT-1LVP EXIST/GYP.BD.EXIST/ MATCH PT-3EXISTING EXISTING
FLEX WORKSPACE PT-6LVP EXIST/GYP.BD.EXIST/ MATCH EXISTING EXISTINGMATCH EXIST.
PT-1LVP EXIST/GYP.BD.EXIST/ MATCH EXISTING EXISTINGMATCH EXIST.
OFFICE
OFFICE
PT-1LVP EXIST/GYP.BD.EXIST/ MATCH EXISTING EXISTING
PT-1LVP EXIST/GYP.BD.EXIST/ MATCH EXISTING EXISTING
ALCOVE LVP EXISTING EXISTING PT-1 PT-3EXISTING EXISTING
PT-3
PT-3
CONFERENCE ROOM LVP EXISTING EXISTING PT-8 PT-3EXISTING EXISTING
OFFICE PT-1LVP EXIST/GYP.BD.EXIST/ MATCH EXISTING EXISTINGPT-3
OFFICE PT-1LVP EXIST/GYP.BD.EXIST/ MATCH EXISTING EXISTINGPT-3
RECEPTIONIST PT-7LVP EXIST/GYP.BD.EXIST/ MATCH EXISTING EXISTINGPT-3
LVPCORRIDOR EXISTING EXISTING PT-1 EXISTING EXISTINGEXIS ACT
EXISTING
OFFICE PT-1LVP EXIST/GYP.BD.EXIST/ MATCH EXISTING EXISTINGEXIS ACT
ALCOVE LVP PT-1EXIST/GYP.BD.EXIST/ MATCH EXISTING EXISTINGPT-3
LOBBY LVP PT-8EXIST/GYP.BD.EXIST/ MATCH EXISTING EXISTINGPT-3
141 SPRINKLER RISER RM CONCRETE PT-1GYP.BD.EXIST/ MATCH OPEN VARIESPT-3
LVP
LVP
LVP
LVP
LVP
LVP
TRIM
Finish
PT-2
PT-2
PT-2
PT-2
PT-2
PT-2
PT-2
PT-2
PT-2
PT-2
PT-2
PT-2
PT-2
PT-2
PT-2
PT-2
PT-2
PT-2
PT-2
PT-2
PT-2
PT-2
PT-2
PT-2
PT-2
PT-2
PT-2
PT-2
PT-2
PT-2
PT-2
PT-2
PT-2
PT-2
PT-2
PT-2
PT-2
PT-2
PT-2
PT-2
PT-2
PT-4 / T-1
PT-4 / T-1
PT-4 / T-1
PT-4 / T-1
PT-4 / T-1
PAN FLASHING IN
SEALANT
HEAD
SILL
SILL BELOW
FLYASH 5/4 X 4
TRIM
5/4 X 4 TRIM
CONCEALED
FLASHING
CONCEALED
FLASHING
TR. 2 X 4
DRIP CUT
@ 15 DEGREE
ANGLE
CONCEALED
FLASHING
JAMB
5/4x4 FLYASH
TRIM
1/2"PLYWOOD
SHEATHING
TYP. SIDING
EXPOSED CAP
FLASHING
1 1/2"X 2 1/2"
FLYASH
DRIP CAP
8'-8"
4'-9"
6'-0"
4'-9"
3'-0"
3'-0"
6'-0"
4'-0"
3'-0"
2'-8"
5'-0"
3'-4"
3'-0"
MARK B
WINDOW
MARK A
WINDOW
MARK C
WINDOW
MARK D
WINDOW
4'-9" X 6'-0"
4'-9" X 8'-8"
A
B
ROUGH OPENING
SIZEMARK TYPE
WINDOW SCHEDULE
1. SIERRA PACIFIC WOOD WINDOWS W/ ARGON FILLED,
LOW-E GLASS, 5/8" SDL, & IMPACT GLASS - COLOR TO
MATCH EXISTING - SEE ELEVATIONS FOR LITE PATTERN
INCLUDES 2'-8" TRANSOMCASEMENT W/TRANSOM
CASEMENT
4'-0" X 6'-0"C CASEMENT
3'-4" X 5'-0"D CASEMENT
SCALE: 1 1/2"= 1'-0"
2WINDOW DETAILS
A.1.3 SCALE: 1/4" = 1'-0"
1WINDOW ELEVATIONS
A.1.3
Page 21 of 69
A R CH ITECT S
A R CH ITECT S
parkerdesigngrouparchitects
843 785 5171 POST OFFICE BOX 5010 HILTON HEAD ISLAND SC 29938
A facility upfit for:
Hilton Head Island, South Carolina
Memory MaƩers
REVISIONS DATE
DATE OF ISSUE:
SHEET
SGK
SCALE
DRAWN BY
CHECKED BY
JOB NO.
These documents & designs are
the property of Parker Design
Group|Architects & are not to
be used or reproduced there of or
for designs, working drawings,
or construction of buildings
without the written authorization
from the copyright owner
PDG|Architects 2025 copyright C
2546
@ 15 Trellis Court
FOR
FINAL
STATE REVIEW
A.1.4
FURNITURE PLAN
7/27/2026
WTP
DPH PROJECT
#1016806
DCB48
B36
B36
B36 B36
B8115
B36
B36
DCB48
B36
B36
B36 B36
B8115
B36
B36
101
102
103
104
105
106
107
108
109
FOUR SEASONS
ROOM
110
111
112
ART ROOMMUSIC ROOM
113
114
115
116
CORR. 117
118
119
120
CORR. 122
CLASS ROOM
123
124
125
126127
128
129
130
OFFICE
131
132
134
CONFERENCE 135 136
138
CORR. 136
139
140
ENTRANCE LOBBY
141
SPRINKLER
RISER
Room # Room Furniture
101 Daycare Entrance
Lockers - Custom Integrity Cabinetry
Benches - Lexington Abbott Benches
Chest - Sunset Key Kenan Hall
102 Restroom N/A
103 Restroom N/A
104 Brain Games Existing Tables and Chairs
105 General Program Existing Tables and Chairs
106 Walk In Storage N/A
107 Breezeway N/A
108 Four Seasons Existing Tables and Chairs
109 Catering Kitchen N/A
110 Ante Room N/A
111 Art Room Existing Tables and Chairs
112 Restroom N/A
113 Ante Room N/A
114 Restroom N/A
115 Ante Room N/A
116 Music Room Existing Tables and Chairs
117 Corridor N/A
118 Resting Room Pottery Barn Secretary Desk
119 Corridor N/A
120 Restroom N/A
121 Staff Coffee N/A
122 Corridor N/A
123 Classroom Existing Tables and Chairs
124 Corridor N/A
125 Ante Room N/A
126 Restroom N/A
127 Janitor/Laundry N/A
128 Flex Workspace Existing Desk, Chair, File Cabinet
129 Office Existing Desk, Chair, File Cabinet
130 Office Existing Desk, Chair, File Cabinet
131 Office Existing Desk, Chair, File Cabinet
132 Alcove N/A
133 Conference Room
Conference Table - Theodore Alexander Gabrielle's
Chairs - Hooker Sonora Dining Chair
134 Office Existing Desk, Chair, File Cabinet
135 Office Existing Desk, Chair, File Cabinet
136 Receptionist Existing Desk, Chair, File Cabinet
137 Corridor 2 Console Tables - Century Cadence
SCALE: 1/8" = 1'-0"
1FURNITURE PLAN
A.1.4
FURNITURE LIST
Page 22 of 69
A R CH ITECT S
A R CH ITECT S
parkerdesigngrouparchitects
843 785 5171 POST OFFICE BOX 5010 HILTON HEAD ISLAND SC 29938
A facility upfit for:
Hilton Head Island, South Carolina
Memory MaƩers
REVISIONS DATE
DATE OF ISSUE:
SHEET
SGK
SCALE
DRAWN BY
CHECKED BY
JOB NO.
These documents & designs are
the property of Parker Design
Group|Architects & are not to
be used or reproduced there of or
for designs, working drawings,
or construction of buildings
without the written authorization
from the copyright owner
PDG|Architects 2025 copyright C
2546
@ 15 Trellis Court
FOR
FINAL
STATE REVIEW
A.2.0
EXTERIOR
ELEVATIONS
7/27/2026
WTP
DPH PROJECT
#1016806
4-SEASON ROOM ADDITIONEXISTING BUILDING
2'-0" MIN. @ BUS DROP-OFF
1'-0"
TYP.
14'-0" MSL -
T.O. FLOOR
BREEZEWAY ADDITION
7
12
7
12
B B B BC
1'-0"
TYP.
10'-0" RAMP
@ 1:12 SLOPE 7'-0" RAMP
@ 1:12 SLOPE
3
12
24'-0"
4-SEASON ROOM ADDITION
EXISTING BUILDING
10'-0"
8'-1"
SPRINKLER RM.
9'-6"
25'-0" LONG 1:12 CONCRETE RAMP - BROOM FINISH
EQ. EQ. EQ. EQ.
7'-0"
6'-8" MIN. (A.D.A)
6'-8" MIN. (A.D.A.)
6'-8" MIN. (A.D.A)
14'-0" MSL -
T.O. FLOOR
NEW KITCHEN DOOR
EXIS. CONCRETE STEPS
& COMPLIANT RAILINGS
NEW DOWNSPOUT
& GUTTER
FOR ADDED ROOF
NEW WALL, BEYOND -
W/ 7" EXPOSURE
FLYASH SIDING
& FLYASH TRIM
ROOF SLOPES AT
1/2" PER FOOT
EXIS. CONCRETE STEPS
& NEW A.D.A.-COMPLIANT
RAILINGS
NEW EXIT DOOR WITH
REVERSED SWING NEW WINDOW
REPLACES
FORMER DOOR
4" CONCRETE WALK
LEADS TO SENSORY
GARDEN
7
12
7
12
B B B B
INFILL STUCCO
AS REQUIRED
METAL ROOF MATCHES EXISTING
EXISTING EMERGENCY
EGRESS LIGHT
DOOR PAINT TO
MATCH EXISTING
7/8" STUCCO ON METAL LATH -
MATCH EXISTING AS CLOSELY
AS POSSIBLE
CABLE RAILING SYSTEM
COTTERMAN FIXED
STEEL LADDER WITH
LOCKABLE
COTTERMAN LADDER
GUARD, OR SIMILAR
METAL CANOPIES W/ WIRE TIEBACKS-
MITCHELL METALS OR SIMILAR
PATCH STUCCO
AT REMOVED
EGRESS LIGHT
NEW STELLA OUTDOOR
FLOOD LIGHT IN EXISTING
JUNCTION BOX
NEW STELLA OUTDOOR
FLOOD LIGHT ON SAME
CIRCUIT AS ADJACENT
FLOOD LIGHTS
9'-0"
12'-4"
NEW BREEZEWAY
24'-0"
4-SEASONS ROOM ADDITION
EXISTING BUILDING
3'-0" 6'-0" 2'-8"
9'-7"
1'-0"
TYP.
11'-0" 2'-6"
2'-0"
R 1'-6"
TYP.
2'-0"
12'-1"
4'-9"
EXISTING
STUCCO
EXTERIOR
FINISH
EXISTING
METAL
ROOF
METAL ROOF
TO MATCH
EXISTING
EXISTING
CLAD
WINDOWS
NEW
CLAD
WINDOWS
CLAD WINDOWS
TO MATCH
EXISTING
POLY-ASH
TRIM & PILASTERS,
TYPICAL
POLY-ASH
LAP SIDING -
3 1/2" EXPOSURE -
TYPICAL
FYPON
BRACKETS
14'-0" MSL -
T.O. FLOOR
10'-0" RAMP
@ 1:12 SLOPE7'-0" RAMP
@ 1:12 SLOPE
CANOPY, POST,
& BRACKET
COLOR MATCHES
STUCCO
7/8" STUCCO ON
METAL LATH -
MATCH EXISTING
AS CLOSELY AS
POSSIBLE
7
12
7
12
A A B B BB
1x4 POLY-ASH TRIM
& HARDIE PANELS,
TYPICAL
7" EXPOSURE
FLY-ASH SIDING
X
A.3.0
UPSIDE
INNOVATIONS
CANOPIES -
SEE PLAN
SCALE: 3/16" = 1'-0"
2FRONT (SOUTH) ENTRY ELEVATION
A.2.0
SCALE: 3/16" = 1'-0"
3BACK (NORTH) ELEVATION
A.2.0
SCALE: 3/16" = 1'-0"
1FOUR-SEASONS ROOM (EAST) ELEVATION
A.2.0
Page 23 of 69
A R CH ITECT S
A R CH ITECT S
parkerdesigngrouparchitects
843 785 5171 POST OFFICE BOX 5010 HILTON HEAD ISLAND SC 29938
A facility upfit for:
Hilton Head Island, South Carolina
Memory MaƩers
REVISIONS DATE
DATE OF ISSUE:
SHEET
SGK
SCALE
DRAWN BY
CHECKED BY
JOB NO.
These documents & designs are
the property of Parker Design
Group|Architects & are not to
be used or reproduced there of or
for designs, working drawings,
or construction of buildings
without the written authorization
from the copyright owner
PDG|Architects 2025 copyright C
2546
@ 15 Trellis Court
FOR
FINAL
STATE REVIEW
A.3.0
BUILDING & WALL
SECTIONS
7/27/2026
WTP
DPH PROJECT
#1016806
10'-0"
15'-10"
14'-3 1/2" MSL -
T.O. FLOOR
7
12
4-SEASONS ROOM PLATE
PASS-THROUGH
CATERING
KITCHEN
7
12
ACOUSTICAL
TILE SYSTEM
ATTIC MINI-SPLIT
SYSTEM
BY OTHERS
EXISTING
BUILDING
4
A.3.0
1
A.3.0
WINDOWS -
BEYOND
5
A.3.0
9'-0"
10'-0"
10'-0"
1'-9"
4'-0" 24'-0"
11'-0" 4'-10"
10'-0"
COVERED
PORCH PLATE PASS-THROUGH BREEZEWAY
EDGE OF
PILASTER
1X1 OVER 1X12 FLYASH
TRIM BOARD
FLY-ASH LAP SIDING -
7" EXPOSURE, TYPICAL
1X6 FLY-ASH TRIM
BOARDS AT CORNERS
AND FRIEZE BAND,
TYP. ON THIS PORCH
RUN FLASHING UP
WALL BEHIND SIDING
2X12 FLY ASH BASE
TRIM W/2X4 SILL ON
TOP
FLY-ASH LAP SIDING -
7" EXPOSURE, TYPICAL
1X6 FLY-ASH TRIM
BOARDS
TYPICAL METAL ROOF
& ROOF TRIM
WALL BLOCKING AT
PLYWOOD SEAMS
3
A.3.0
1
12
7
12
7
12
ACOUSTICAL TILE
SYSTEM
14'-3 1/2" MSL -
T.O. FLOOR
EXISTING CONCRETE
STEPS TO REMAIN
2X4 HARDIE TRIM
CONTINUOUS CLEAT
1/2" PLYWOOD SHEATHING W/
TYVEK DRAIN WRAP V.B. OR EQ.
T.O. PARAPET WALL
15'-10" +/-
METAL COPING COVER
TO MATCH EXISTING ROOFING
2x6'S @ 16" O.C. -
SEE STRUCTURAL
TYPICAL SIDING
1'-0"
FLYASH 1X4 ON TR.
BLOCKING & FLYASH
1X6 TRIM
HURRICANE CLIPS -
SEE STRUCTURAL
2x6'S @ 16" O.C. WITH 1/2"
PLYWD. SHEATHING &
TYVEK DRAINWRAP OR EQ.
SOFFIT BOARD WITH 1X2
BATTENS AT WALL AND
PERPENDICULAR @
8'-0" O.C.
FLYASH 2X6 TRIM BOARD
TYPICAL SIDING
MTL. DRIP EDGE- COLOR
TO MATCH ROOFING TO
THE GREATEST EXTENT
POSSIBLE.
GRACE ICE & WATER
SHIELD HT OR EQUAL
OVER CDX 5/8" PLYWOOD
STANDING SEAM
ALUMINUM ROOFING -
MATCH EXISTING
3
12
SEE STRUCTURAL FOR
FOOTER AND REBAR
NOTES
PARGE BLOCK BELOW
TO MATCH STUCCO
SEE STRUCTURAL FOR
ANCHOR NOTES
RUN STUCCO UNDER TRIM
8" C.M.U. W/ CONC.
FILLED CELLS- SEE
STRUCTURAL FOR NOTES
EXPOSED COPPER
FLASHING
CUT TR. 2X4 DRIP TRIM
1X12 FLYASH TRIM ON
TR. 1X3 BLOCKING
1/2" SHEETROCK
TYP. BASE TRIM
OPEN CELL SPRAY FOAM
INSULATION EQUAL TO
R-19 14'-3 1/2" MSL -
T.O. FLOOR
4" 3000 PSI CONC. SLAB
W/ 6X6 10/10W.W.F.-
FLOAT FINISH
10 MILL VAPOR
BARRIER
COMPACTED &
TREATED SOIL
COMPACTED &
TREATED SOIL
1X FLYASH TRIM
1/4" HARDIE PANEL
7/8" CEMENT STUCCO
ON METAL LATH, #15
FELT - MATCH STUCCO
AS CLOSELY AS
POSSIBLE TO EXISTING
1'-9"
FLYASH 1X4 ON TR.
BLOCKING & FLYASH
1X6 TRIM
HURRICANE CLIPS -
SEE STRUCTURAL
2x6'S @ 16" O.C. WITH 1/2"
PLYWD. SHEATHING &
TYVEK DRAINWRAP OR EQ.
SOFFIT BOARD WITH 1X2
BATTENS AT WALL AND
PERPENDICULAR @
8'-0" O.C.
FLYASH 2X6 TRIM BOARD
TYPICAL SIDING - SEE
EXT. ELEVATIONS
MTL. DRIP EDGE- COLOR
TO MATCH ROOFING TO
THE GREATEST EXTENT
POSSIBLE.
GRACE ICE & WATER
SHIELD HT OR EQUAL
OVER CDX 5/8" PLYWOOD
STANDING SEAM
ALUMINUM ROOFING -
MATCH EXISTING
ALUMINUM RAIN GUTTERS
TO MATCH EXISTING
7
12
TRUSS DESIGN
BY OTHERS
OPEN CELL SPRAY FOAM
INSULATION EQUAL TO
R-19
1'-0"
TYP.
TYPICAL RAMP
@ 1:12 SLOPE
ROOF W-PANS
DRAIN TO GUTTER
6" FASCIA GUTTER
CUSTOM LOW-
COUNTRY METAL
TUBE BRACKETS
POST FLANGES
BOLT TO
CONCRETE
FOUNDATION
INTERNAL DRAINAGE
IN HOLLOW POSTS
TO GROUND
POWDER-COATED
CANOPY MEMBERS
MATCH BEIGE
STUCCO
POWDER-COATED
BRACKETS MATCH
BEIGE STUCCO
EPOXY #4 DOWELS INTO
EXISTING FOUNDATION
WALL & CMU AT 16" O.C.
IN BOTH DIRECTIONS
MATCH FOOTING DEPTH
TO EXISTING FOUNDATION
DEPTH
ALIGN OLD AND NEW
FLOOR LEVELS
1/2" GYP. BD. ON BOTH SIDES
OF 2X6 AND 2X4 TO FILL
FORMER OVERHEAD DOOR
SPACE FLUSH WITH
ADJACENT WALLS
SEE STRUCTURAL FOR
WALL & FOOTING
REINFORCEMENT
COMPACTED &
TREATED SOIL
EXISTING
FOUNDATION
COMPACTED &
TREATED SOIL
10 MILL VAPOR
BARRIER
4" 3000 PSI CONC. SLAB
W/ 6X6 10/10W.W.F.-
FLOAT FINISH
SCALE: 1/4" = 1'-0"
7PARTIAL BUILDING SECTION
A.3.0SCALE: 1/4" = 1'-0"
6SECTION THROUGH BACK PORCH
A.3.0
SCALE: 1" = 1'-0"
3WALL PARAPET SECTION
A.3.0SCALE: 1" = 1'-0"
2 BREEZEWAY-EAVE DETAIL
A.3.0SCALE: 1" = 1'-0"
1TYPICAL WALL-FDN. DETAIL
A.3.0 SCALE: 1" = 1'-0"
4HIP ROOF EAVE
A.3.0
SCALE: 1/2" = 1'-0"
8TYPICAL METAL CANOPY SECTION
A.3.0
SCALE: 1" = 1'-0"
5FOUNDATION CONNECTION
A.3.0
Page 24 of 69
A R CH ITECT S
A R CH ITECT S
parkerdesigngrouparchitects
843 785 5171 POST OFFICE BOX 5010 HILTON HEAD ISLAND SC 29938
A facility upfit for:
Hilton Head Island, South Carolina
Memory MaƩers
REVISIONS DATE
DATE OF ISSUE:
SHEET
SGK
SCALE
DRAWN BY
CHECKED BY
JOB NO.
These documents & designs are
the property of Parker Design
Group|Architects & are not to
be used or reproduced there of or
for designs, working drawings,
or construction of buildings
without the written authorization
from the copyright owner
PDG|Architects 2025 copyright C
2546
@ 15 Trellis Court
FOR
FINAL
STATE REVIEW
A.3.1
SECTIONS & DETAILS
7/27/2026
WTP
DPH PROJECT
#1016806
3'-0"
9'-0"
SPRINKLER
RISER ROOM
SPRINKLER
RISER
DESIGN BY
OTHERS
3
12
METAL CANOPY W/
WIRE TIEBACKS -
MITCHELL METALS
OR SIMILAR
ART ROOM
EXISTING
BUILDING
A.3.1
1
A.3.1
2
REMOVE EXISTING GUTTER &
DOWNSPOUT AT ADDITION
& RE-SLOPE REMAINING
GUTTERS AS REQUIRED
3
12
FLYASH 1X6 ON TR.
BLOCKING & FLYASH
1X4 TRIM
HURRICANE CLIPS -
SEE STRUCTURAL
HARDIE SOFFIT BOARD
WITH 1X2 BATTENS AT
EDGE & WALL
OPEN-CELL SPRAY FOAM
INSULATION EQ. TO R-30
MTL. DRIP EDGE- COLOR
TO MATCH ROOFING TO
THE GREATEST EXTENT
POSSIBLE.
GRACE ICE & WATER
SHIELD HT OR EQUAL
OVER CDX 5/8" PLYWOOD
STANDING SEAM
ALUMINUM ROOFING -
MATCH EXISTING
2X4 FRAMING AT
16" O.C. W/OPEN-CELL
SPRAY FOAM INSULATION
EQ. TO R-19
SPRINKLER SYSTEM
DESIGN BY OTHERS
1/2" PLYWOOD SHEATHING
MTL. DRIP EDGE- COLOR
TO MATCH ROOFING TO
THE GREATEST EXTENT
POSSIBLE.
7/8" CEMENT STUCCO
ON METAL LATH, #15
FELT, & TYVEC STUCCO
WRAP OR EQUAL -
MATCH STUCCO AS
CLOSELY AS POSSIBLE
EXISTING
BUILDING
T.O. SLAB 12.5 MSL
14'-3 1/2" MSL -
T.O. FLOOR
10 MILL VAPOR
BARRIER, TYP.
4" 3000 PSI CONC. SLAB
W/ 6X6 10/10W.W.F.-
FLOAT FINISH
COMPACTED &
TREATED SOIL
EPOXY #4 DOWELS
INTO EXISTING
FOUNDATION WALL
EXISTING
FOUNDATION
MATCH FOOTING DEPTH
TO EXISTING FOUNDATION
DEPTH
SEE STRUCTURAL FOR
CONCRETE REINFORCEMENT
1/4" : 1'-0"
SLOPE
2X4 FRAMING AT
16" O.C. W/OPEN-CELL
SPRAY FOAM INSULATION
EQ. TO R-19
1/2" PLYWOOD SHEATHING
7/8" CEMENT STUCCO
ON METAL LATH, #15
FELT, & TYVEC STUCCO
WRAP OR EQUAL -
MATCH STUCCO AS
CLOSELY AS POSSIBLE
COMPACTED &
TREATED SOIL
SIMPSON ABU44Z
STAINLESS STEEL
CONNECTION
TR. 4X4 POSTS
SLOPE CONCRETE
1/4" PER 1'-0"
COMPACTED &
TREATED SOIL
(2) CONT. #5 BARS W/
PERP. #5'S @ 32" O.C.-
SEE STRUCTURAL
4" 3000 PSI
CONCRETE SLAB
W/ BROOM FINISH
FOR HEAT PUMPS
ELEV 12.4 MSL
TR. 2X8 CAP
SLOPE SLIGHTLY
1 X 6 TRIM
TR. 2 x 4's
TR. 1 x 4 FRAME;
TOP & BOTTOM
1 X 4 TREATED WD. BLADES
1 X 6 TRIM
TR. 6X6 CHAMFERED
POSTS, BEYOND
2X8 FLY ASH TRIM BOARD
FYPON BRACVKET TBD
1X6 FLY ASH TRIM BOARD
2X4 FLY ASH TRIM BOARD
AZEK PVC OR FLY ASH
TRIM BOARD - 12" ACTUAL
2X6 FLY ASH TRIM BOARD
1X4 FLY ASH TRIM BOARDS, TYP.
2X2 FLY ASH TRIM BOARD
1X4 FLY ASH TRIM BOARDS, TYP.
1X4 FLY ASH TRIM BOARDS, TYP.
1/4 HARDIE PANEL
1/4 HARDIE PANEL
1X4 FLY ASH TRIM BOARDS, TYP.
3/4" FLY ASH QUARTER ROUND
1X12 FLY ASH TRIM BOARDS, TYP.
7/8" CEMENT STUCCO
ON METAL LATH, #15
FELT - MATCH STUCCO
AS CLOSELY AS
POSSIBLE TO EXISTING
PARGED STUCCO
6'-8"
4" 3000 PSI CONCRETE
SLAB W/ BROOM FINISH -
SLOPE 1/4" PER FOOT
TOWARD BACK -
SEE STRUCTURAL
(2) CONT. #5 BARS W/
PERP. #5
BARS -
SEE STRUCTURAL
COMPACTED &
TREATED SOIL
ALUM. LOUVERS
W/ 1" GAP
7/8" CEMENT STUCCO
ON METAL LATH -
COLOR TO
MATCH BUILDING
PRECAST CONCRETE
CAP WITH DRIP AND
SLOPED TO DRAIN
SEE STRUCTURAL
FOR CMU & FOOTER
NOTES AND
DIMENSIONS
12"x12" CMU PIER
BLOCKS, TYP.
SIMPSON STRONG TIE
GALVANIZED POST BASE
TR. SLOPED
TOP, TYPICAL
A.3.1
5
7'-0"
9'-8"
4-YARD
DUMPSTER
BY OTHERS
CONCRETE-FILLED
BOLLARDS
CONCRETE APRON
& DUMPSTER PAD
LOUVERED GATES
ALUMINUM LOUVERS
SEE 5/A.3.1
TR. 6x6 TYP.
DRILL HOLES IN
CONCRETE FOR 3/4"
METAL CANE BOLT
USE IN BOTH CLOSED
AND OPEN POSITIONS,
TYPICAL
ALUMINUM LOUVERS
SEE 5/A.3.1
ALUMINUM LOUVERS
SEE 5/A.3.1
+/- 5'-10"
TR. 6X6 POSTS,
TYPICAL
ALUM. GATE FRAME
AS PER OTHERS
5 1/2" WIDE
ALUM. LOUVERS
COLOR T.B.D.
STUCCO POSTS -
SEE 5/A.3.1
TR. SLOPED
TOP, TYPICAL
SCALE: 1/2" = 1'-0"
3LEAN-TO SPRINKLER RM SECTION
A.3.1
SCALE: 1" = 1'-0"
1SPRINKLER RM. ROOF SECTION
A.3.1
SCALE: 1" = 1'-0"
2SPRINKLER RM FOUNDATION SECTION
A.3.1SCALE: 1" = 1'-0"
4SAFETY FENCE SECTION
A.3.1
SCALE: 1" = 1'-0"
6TYPICAL PILASTER
A.3.1 SCALE: 1" = 1'-0"
5DUMPSTER ENCLOSURE SECTION
A.3.1SCALE: 1/2" = 1'-0"
8ENLARGED DUMSPTER ENCLOSURE
A.3.1
SCALE: 1/2" = 1'-0"
7GATES - TRASH ENCLOSURE
A.3.1
Page 25 of 69
A R CH ITECT S
A R CH ITECT S
parkerdesigngrouparchitects
843 785 5171 POST OFFICE BOX 5010 HILTON HEAD ISLAND SC 29938
A facility upfit for:
Hilton Head Island, South Carolina
Memory MaƩers
REVISIONS DATE
DATE OF ISSUE:
SHEET
SGK
SCALE
DRAWN BY
CHECKED BY
JOB NO.
These documents & designs are
the property of Parker Design
Group|Architects & are not to
be used or reproduced there of or
for designs, working drawings,
or construction of buildings
without the written authorization
from the copyright owner
PDG|Architects 2025 copyright C
2546
@ 15 Trellis Court
FOR
FINAL
STATE REVIEW
A.5.0
ENLARGED FLOOR
PLANS & ELEVS
7/27/2026
WTP
DPH PROJECT
#1016806
2
A.5.0
3
A.5.0
4
A.5.0
1'-4"
4" 3'-0"
R 2'-9 1/2"
7'-8"
1'-0" 2'-4" 1'-2" 2'-2"
6'-8"
2'-8"
TOILET TISSUE
DISPENSER
FD
GFCI
C
WP
PAPER
TOWEL
DISPENSER
PULL
CORD
SANITARY
DISPENSER
NAMEEKS TECLA
CONSOLE PER
INTERIORS
DELTA
SAYLOR
FAUCET
6
A.5.0
7
A.5.0
8
A.5.0
R 2'-9 1/2"
1'-4"
8'-2"
4" 1'-0" 2'-0"
1'-0" 2'-4" 1'-2" 2'-2"
6'-8"
PULL
CORD
FD
GFCI
C
WP
PAPER
TOWEL
DISPENSER
TOILET TISSUE
DISPENSER
SANITARY
DISPENSER
NAMEEKS TECLA
CONSOLE PER
INTERIORS
DELTA
SAYLOR
FAUCET
10
A.5.0
R 2'-9 1/2"
1'-2" 2'-4" 1'-0"
4" 3'-0"
1'-9"
3'-9 1/2" 3'-10" 7'-1"
14'-8 1/2"
1'-4"
6'-8"
3'-6" 3'-2"
C
SANITARY
DISPENSER
FD
PAPER
TOWEL
DISPENSER
TOILET TISSUE
DISPENSER
GFCI
WP
SHOWER UNIT WITH SEAT-
FREEDOM SHOWERS
APFQ3637BF3PR OR
SIMILAR
PULL CORD
ALERTS
RECEPTIONIST
3'-4" 1'-6"
3'-0"
1'-5"
2'-10"
1'-6"
4'-0"
PROVIDE SOLID
BLOCKING IN
WALLS AT
GRAB BARS
STAINLESS
STEEL GRAB
BARS, TYP.
BLOCK WALL AT
SINK & BRACING
POINTS
EBERN JAVEION
MIRROR PER
INTERIORS
NAMEEKS TECLA
BATHROOM
CONSOLE PER
INTERIORS
24" GRAB
BAR
FREEDOM SHOWER ADA
PREFAB SHOWER Model
APFXST3838BF.625
FOLD UP
SEAT
L-SHAPED
GRAB BAR
1'-10"
3'-0"
1'-5"
1'-6"3'-4"
7"2'-3"
1'-10"
4" MAX. TO REFLECTING SURFACE
PROVIDE SOLID
BLOCKING IN
WALL FOR GRAB
BARS, TYP.
BLOCK WALL AT SINK
& BRACING POINTS
PULL CORDS ALERT
RECEPTIONIST
EBERN JAVEION
MIRROR PER
INTERIORS
NAMEEKS TECLA
BATHROOM
CONSOLE PER
INTERIORS
1'-5"
1'-6"3'-4"
1'-10"
2'-3" 7" 4" MAX. TO REFLECTING SURFACE
PROVIDE SOLID
BLOCKING IN
WALL FOR GRAB
BARS, TYP.
BLOCK WALL AT SINK
& BRACING POINTS
PULL CORDS ALERT
RECEPTIONIST
EBERN JAVEION
MIRROR PER
INTERIORS
NAMEEKS TECLA
BATHROOM
CONSOLE PER
INTERIORS
LAVATORY
VITREOUS CHINA
ARCHER
K-2355
4'-0"
2'-10" ADA 4"
TOWEL
DISPENSER
PROVIDE SHROUD
FOR PLUMBING
NAMEEKS TECLA
BATHROOM
CONSOLE PER
INTERIORS
PROVIDE WALL
BLOCKING
DELTA
SAYLOR
FAUCET
3'-4" 1'-6"
3'-0"
1'-10"
4'-0"
PROVIDE SOLID
BLOCKING IN
WALLS AT
GRAB BARS
STAINLESS
STEEL GRAB
BARS, TYP.
3'-4" 1'-6"
3'-0"
1'-10"
4'-0"
PROVIDE SOLID
BLOCKING IN
WALLS AT
GRAB BARS
STAINLESS
STEEL GRAB
BARS, TYP.
LAVATORY
VITREOUS CHINA
ARCHER
K-2355
4'-0"
2'-10" ADA 4"
PROVIDE SHROUD
FOR PLUMBING
TOWEL
DISPNSER
NAMEEKS TECLA
BATHROOM
CONSOLE PER
INTERIORS
PROVIDE WALL
BLOCKING
DELTA
SAYLOR
FAUCET
1'-6"
2'-10" ADA 1'-6" 3'-8"
32" ADA
BASE CAB.
2x4 S-4-S
AS CROWN -
PAINT
ARTWORK
OR
MEMORY
MATTERS
IMAGERY
CAMBRIA IRONSBRIDGE
QUARTZ AS PER INTERIORS
WOOD SHAKER CABINETS PAINTED PT2, TYPICAL
32" X 44"
WALL CAB.
32" X 44"
WALL CAB.
32" ADA
BASE CAB.
32" ADA
BASE CAB.
DESCRIPTION
TOILET ROOM ACCESSORY SCHEDULE
18" GRAB BAR
DOUBLE TOILET ROLL
36" GRAB BAR
42" GRAB BAR
BRADLEY WASHROOM
ACCESSORIES ARE BASIS
OF DESIGN U.N.O.
MANUFACTURER
BRADLEY
MODEL NUMBER REMARKS
BRADLEY
BRADLEY
BRADLEY
SATIN CHROME
ROLLED HAND TOWEL BRADLEY
SATIN CHROME
SATIN CHROME
SATIN CHROME
SATIN CHROME
8120-001180
8120-001360
8120-001420
522-00
2A01-11
ADA MIRROR
TRASH CONTAINER PROVIDED BY OWNER
EBERN DESIGN JAVEION SKU # ENDG2891
SANITARY DISPOSAL BRADLEY 4A10-11000 SATIN CHROME
CLOTHES HOOK BRADLEY 932 INSIDE OF RR DOORS
MOP SHELF/HOOKS BRADLEY 9983 ABOVE MOP SINK
SCALE: 1/2" = 1'-0"
1ENLARGED RESTROOM 103
A.5.0
SCALE: 1/2" = 1'-0"
5ENLARGED RESTROOM 114
A.5.0
SCALE: 1/2" = 1'-0"
9SHOWER & RESTROOM
A.5.0SCALE: 1/2" = 1'-0"
10SHOWER WALL ELEVATION
A.5.0
SCALE: 1/2" = 1'-0"
2WET WALL ELEVATION RM 103
A.5.0
SCALE: 1/2" = 1'-0"
6WET WALL ELEVATION RM 114
A.5.0
SCALE: 1/2" = 1'-0"
4VANITY SECTION/ELEVATION
A.5.0 SCALE: 1/2" = 1'-0"
3ROOM 103 SIDE ELEV.
A.5.0
SCALE: 1/2" = 1'-0"
7ROOM 114 SIDE ELEVATION
A.5.0SCALE: 1/2" = 1'-0"
8VANITY SECTION/ELEV 114
A.5.0
SCALE: 1/2" = 1'-0"
11ART ROOM CABINETS
A.5.0
RESTROOM 102
SIMILAR
Page 26 of 69
A R CH ITECT S
A R CH ITECT S
parkerdesigngrouparchitects
843 785 5171 POST OFFICE BOX 5010 HILTON HEAD ISLAND SC 29938
A facility upfit for:
Hilton Head Island, South Carolina
Memory MaƩers
REVISIONS DATE
DATE OF ISSUE:
SHEET
SGK
SCALE
DRAWN BY
CHECKED BY
JOB NO.
These documents & designs are
the property of Parker Design
Group|Architects & are not to
be used or reproduced there of or
for designs, working drawings,
or construction of buildings
without the written authorization
from the copyright owner
PDG|Architects 2025 copyright C
2546
@ 15 Trellis Court
FOR
FINAL
STATE REVIEW
A.5.1
ENLARGED FLOOR
PLANS & ELEVS
7/27/2026
WTP
DPH PROJECT
#1016806
2
A.5.1
7'-6 1/2" 4'-6" 7'-6 1/2"
19'-7"
R 2'-9 1/2" R 2'-9 1/2"
10'-1"
3'-0" MIN.3'-0" MIN.
1'-6"
MIN.
LOCKED FIRST
AID, ETC.
ADJUSTABLE
MEDICAL BED
FBO
ADJUSTABLE
MEDICAL BED
FBO
POWER-
LIFT
RECLINER
FBO
PULL CORDS ALERT
RECEPTIONIST
LOCKED MEDS.
CABINET
SECRETARY DESK
SELECTED BY
INTERIORS
CUBICLE
CURTAINS
BY OWNER
ON
CEILING TRACK
1'-6"
MIN.
1'-2"
MAX.
1'-6"
MIN.
7
A.5.1
6
A.5.1
5
A.5.1
2'-2" 5'-0" 3'-0" 4'-11" 2'-0"
2'-10"
4'-2"
17'-1"
4'-0" 11'-6" 5'-0" 1'-9"
3'-5 1/2"
3'-2"
PASS-
THRU
SERVING
COUNTER
PROOFER
HEATED
CABINET
TO STAGE
CATERED
FOOD
PANTRY
ICETRO ICE MACHINE W/
DEDICATED WATER LINE,
BACKFLOW PREVENTER,
AND PROTECTED ICE
SCOOP
COVERED
PORCH
DISHWASHER/SANITIZER
BY JACKSON DISHSTAR
HAND SINK
CATERED MEALS
ARRIVE THROUGH
THIS DOOR
ATOSA
ONE-DOOR
REFRIGERATOR
3-COMPARTMENT
STAINLESS STEEL
SINK
STAINLESS STEEL
WORK ISLAND
FOR PLATING FOOD
FOUR-SEASONS
ROOM WITH
DINING TABLES
DOWN
BASE CABINETS
WITH SHELVES
OR CABINETS
ABOVE, TYPICAL
FIRE
EXTINGUISHER
CABINET
ATOSA
ONE-DOOR
FREEZER
3'-0"-WIDE
ELIASON DSP-3
STAINLESS STEEL
16 GA. DOORS
PULL CORDS ALERT
RECEPTIONIST
ADJUSTABLE MEDICAL
BED FBO
PULL CORDS ALERT
RECEPTIONIST
ADJUSTABLE MEDICAL
BED FBO
POWER-LIFT
RECLINER FBO
PULL CORDS ALERT
RECEPTIONIST
CUBICLE
CURTAINS
BY OWNER
ON
CEILING TRACK
2'-10"
7'-0"
22'-3"
2'-6" 2'-2" 4" 7'-0" 1/2" 2'-0" 11" 4'-9"2'-7"
30" X 42"
WALL CAB.
30" ADA
BASE CAB.
HAND SINK
W/ 30" W
KNEE
SPACE,
MIN.
3-COMPARTMENT
SINK T.B.D. DISHWASH/
SANITZER
MACHINE
OPEN SHELVES OR
UPPER CABINETS,
T.B.D.
LOCKABLE
CHEMICALS
CABINET
ICE
SCOOP
ICE
MACHINE
WITH
DEDICATED
COLD WATER
LINE WITH
BACKFLOW
PREVENTER
2'-10" 1'-8" 3'-6"
2"
FILLER
4"
21" X 42"
WALL CAB. 30" X 42"
WALL CAB.
30" ADA
BASE CAB.
30" ADA
BASE CAB.
30" ADA
BASE CAB.
24" ADA
BASE CAB.
PASS-THROUGH
COUNTER
TO 4-SEASONS
ROOM IS CAMBRIA
IRONSBRIDGE
QUARTZ WITH
4"H BACKSPLASH
PROOFER
HEATED
CABINET
EXTERIOR
DOOR WATER
HEATER
CLOSET
WOOD SHAKER CABINETS PAINTED PT2, TYPICAL
4'-4" 3'-8"
ALTOSA
1-DOOR
REFRIG.
36" X 96"
PANTRY
W/ ADJ.
SHELVES
PROOFER
HEATED
CABINET
24" X 96"
PANTRY
W/ ADJ.
SHELVES
36" X 96"
PANTRY
W/ ADJ.
SHELVES
WOOD SHAKER CABINETS PAINTED PT2, TYPICAL
27"Wx31-7/10"Dx83"HA
B
DIMENSIONSMARK MANUFACTURER AND MODEL NUMBER
CATERING KITCHEN EQUIPMENT LIST
ALTOSA REACH-IN FREEZER, MBF8501GR
C
REMARKS
27"Wx31-7/10"Dx83"HALTOSA REACH-IN REFRIGERATOR, MBF8505GR
21"Wx30-3/4"Dx66 1/2"HWINHOLT MOBILE PROOFER CABINET, NHPL-1836-ECOC
D1 84"Wx25 1/2"Dx44 1/4"HSAPPHIRE MFRING 3-COMPARTMENT SINK, SMS-3-1620D
E 17"Wx15"Dx14"HF
24 1/4"Wx25"Dx33 5/16"HJACKSON DISHWASHER/SANITIZER, DISHSTAR HT
G 26"Wx28"Dx39"HICETRO AMERICA (MIDDLEBY) ICEMAKER, IU-0220-AC
H 20 1/2"Wx16"Dx12 1/8"HSHARP MEDIUM-DUTY 1000W MICROWAVE, R-21LCFS
INCLUDES 2 DRAINBOARDS
D2 TAP PRE-RINSE FAUCET, TPRF-812 FOR 3-COMPARTMENT SINK
SAPPHIRE MFRING WALL-MOUNT HAND SINK, SMHS-01-D INCLUDES FAUCET SET
F
INCLUDES FAUCET SET
REQUIRES ICEPRO 500 WATER FILTER
2'-10"
A.D.A.
FILLER FILLER
1'-7"
1'-6"
4"
36" ADA
BASE CAB. -
W/ ADJ. SHELVES
36" ADA
BASE CAB. -
W/ ADJ. SHELVES
36" ADA
BASE CAB. -
W/ ADJ. SHELVES
36" ADA
BASE CAB. -
W/ ADJ. SHELVES
CAMBRIA IRONSBRIDGE COUNTER &
BACKSPLASH, TYP.
WOOD LOUVERED
CABINETS PAINTED PT-2
ARTWORK OR MEMORY MATTERS
IMAGERY AS SELECTED BY
INTERIORS
CABINET
SECTION
1'-6"
2'-10" ADA 1'-6" 3'-8"
32" ADA
BASE CAB.
2x4 S-4-S
AS CROWN -
PAINT
ARTWORK
OR
MEMORY
MATTERS
IMAGERY
CAMBRIA IRONSBRIDGE
QUARTZ AS PER INTERIORS
WOOD SHAKER CABINETS PAINTED PT2, TYPICAL
32" X 44"
WALL CAB.
32" X 44"
WALL CAB.
32" ADA
BASE CAB.
32" ADA
BASE CAB.
2'-10" ADA 1'-6" 3'-10 1/2"
8'-6"
2x4 S-4-S
AS CROWN -
PAINT
36"x42"
BULLETIN
BOARD OF
DAILY
ACTIVITIES,
MENUS,
ETC.
CAMBRIA IRONSBRIDGE
QUARTZ AS PER INTERIORS
WOOD SHAKER CABINETS PAINTED PT2, TYPICAL
32" X 46 1/2"
WALL CAB.
32" X 46 1/2"
WALL CAB.
18" ADA
BASE CAB.
18" ADA
BASE CAB.
DESK
CHAIR
BY
OWNER
SCALE: 1/2" = 1'-0"
1ENLARGED RESTING ROOM
A.5.1
SCALE: 1/2" = 1'-0"
4ENLARGED CATERING KITCHEN
A.5.1
SCALE: 1/2" = 1'-0"
2RESTING ROOM ELEVATION
A.5.1
SCALE: 1/2" = 1'-0"
53-COMPARTMENT SINK WALL ELEVATION
A.5.1
SCALE: 1/2" = 1'-0"
6PASS-THROUGH SERVING COUNTER ELEV
A.5.1
SCALE: 1/2" = 1'-0"
7PANTRY WALL ELEVATION
A.5.1
SCALE: 1/2" = 1'-0"
3CLASSROOM BUFFETT ELEVATION
A.5.1
SCALE: 1/2" = 1'-0"
9MUSIC ROOM CASEWORK
A.5.1
SCALE: 1/2" = 1'-0"
8INFO DESK CASEWORK
A.5.1
Page 27 of 69
STRUCTURAL
NOTES
1. BUILDING CODE:
2021 SOUTH CAROLINA BUILDING CODE (SCBC):
2. GRAVITY LOADS (ASCE 7-16):
DISTRIBUTED
ROOF LL = 20 PSF
DL = 20 PSF
1ST FLOORLL = 50 PSF
DL = 50 PSF
COLLATERAL LOAD CL = 5 PSF
3. WIND LOADS (ASCE 7-16/ 2021 SCBC):
BASIC DESIGN WIND SPEED, V = 145mph
ALLOWABLE STRESS DESIGN WIND SPEED, VASD = 112.3mph
RISK CATEGORY II
WIND EXPOSURE D
INTERNAL PRESSURE COEFFICIENT, GC^pi = ±0.18
4. SEISMIC LOADS (ASCE 7-16/ 2021 SCBC):
RISK CATEGORY II
SEISMIC IMPORTANCE FACTOR, IE = 1.00
MAPPED SPECTRAL RESPONSE ACCELERATION PARAMETERS:
SS = 0.456g; S1 = 0.152g
SITE CLASS D
DESIGN SPECTRAL RESPONSE ACCELERATION PARAMETERS:
SDS = 0.437g; SD1 = 0.233g
SEISMIC DESIGN CATEGORY D
BASIC SEISMIC FORCE-RESISTING SYSTEM:
STEEL ORDINARY MOMENT FRAMES:
V = CsW
W = EFFECTIVE SEISMIC MASS
SEISMIC RESPONSE COEFFICIENT, CS = 0.125
RESPONSE MODIFICATION FACTOR, R = 3.5
ANALYSIS PROCEDURE:
EQUIVALENT LATERAL FORCE METHOD
5.
SNOW LOAD (ASCE 7-16):
GROUND SNOW LOAD Pg = 0 PSF
6. RAIN LOAD DATA (2021 SCBC):
RAIN INTENSITY i = 4.5 in/hr
ROOF: 7 TO 45
DEGREESWALLS
ZONEAREA(SF)+P -PASD
+PASD -P
11042.267.7 25.3 40.6
120 36.5 59.7 21.9 35.8
150 28.9 49.1 17.3 29.5
1100 23.2 41.0 13.9 24.6
2e1042.281.0 25.3 48.6
2e20 36.571.9 21.943.1
2e50 28.9 59.8 17.3 35.9
2e100 23.2 50.6 13.9 30.4
2r1042.2 77.125.3 46.3
2r20 36.5 71.0 21.9 42.6
2r50 28.9 63.0 17.3 37.8
2r100 23.2 57.0 13.9 54.7
3 10 42.291.1 25.3 54.7
3 2036.5 76.4 21.9 45.8
3 5028.957.0 17.3 34.2
3 10023.2 57.0 13.9 34.2
410 57.0 61.8 34.2 37.1
420 54.4 59.2 32.6 35.5
450 51.0 55.8 30.6 33.5
4100 48.4 53.3 29.0 32.0
5 10 57.0 76.3 34.2 45.8
5 20 54.471.132.642.7
5 50 51.0 64.4 30.6 38.6
5 10048.459.2 29.0 35.5
a
aHIP ROOF a = 3.0 FT
5
4
4
a
a
15
1
1
2e
1
3
3
3
3
2e
2r
COMPONENTS & CLADDING
WIND PRESSURES (PSF)
STRUCTURAL NOTESSTRUCTURAL DESIGN CRITERIA
GENERAL REQUIREMENTS
1. WHERE A SECTION OR DETAIL IS SHOWN FOR ONE CONDITION, IT SHALL APPLY TO ALL SIMILAR CONDITIONS.
2. COORDINATE ALL LIMITS AND DEPTHS OF DEPRESSIONS FOR FLOOR FINISHES WITH ARCHITECTURAL
DRAWINGS AND SCHEDULES. LIMITS SHOWN ON STRUCTURAL DRAWINGS ARE SCHEMATIC.
3. THE DESIGN ADEQUACY AND SAFETY OF ERECTION BRACING, SHORING, TEMPORARY SUPPORTS, ETC. SHALL BE
THE SOLE RESPONSIBILITY OF THE CONTRACTOR.
4. DO NOT SCALE DRAWINGS. FOLLOW DIMENSIONS SHOWN ON PLANS.
5. CONTRACTOR SHALL COORDINATE AND VERIFY ALL DIMENSIONS AND ELEVATIONS SHOWN HEREIN WITH
ARCHITECTURAL PLANS, SECTIONS, AND DETAILS PRIOR TO CONSTRUCTION OR MATERIAL PURCHASE AND
SHALL NOTIFY ARCHITECT OR ENGINEER IN WRITING OF DISCREPANCIES. SEE ARCHITECTURAL DRAWINGS
FOR ALL DIMENSIONS AND ELEVATIONS NOT SHOWN HEREIN.
6. DIMENSIONS INDICATED RELATIVE TO AN EXISTING STRUCTURE ARE APPROXIMATE AND SHALL BE FIELD
VERIFIED BY THE CONTRACTOR PRIOR TO CONSTRUCTION OR MATERIALS PURCHASE. CONTRACTOR SHALL
NOTIFY ARCHITECT OR ENGINEER IN WRITING OF DISCREPANCIES.
7. SPECIFIED ANCHOR SYSTEMS SHALL BE INSTALLED IN STRICT ACCORDANCE WITH MANUFACTURER'S WRITTEN
INSTRUCTIONS. SPECIAL ATTENTION SHALL BE GIVEN TO THE DRILLING, CLEANING, AND PREPARATION OF
HOLES. WHERE ADHESIVE ANCHORS ARE SHOWN, SPECIAL ATTENTION SHALL BE GIVEN TO THE REQUIRED
MIXING, APPLICATION, AND CURING TIME OF ADHESIVE TYPE SPECIFIED.
SUBGRADE PREPARATION
1. CONTRACTOR SHALL STRIP AND REMOVE ALL VEGETATION, TOPSOIL, ROOTS, AND ORGANIC SOILS FROM THE
CONSTRUCTION AREA FOR A DISTANCE OF AT LEAST 10' BEYOND THE EXTENT OF BUILDING FOUNDATION
LIMITS. THE DEPTH OF STRIPPING SHALL BE THAT REQUIRED TO REMOVE SIGNIFICANT ROOT ZONES, SMALL
TREE STUMPS, AND OTHER UNACCEPTABLE MATERIALS, BUT IN NO CASE SHALL IT BE LESS THAN 12".
2. AFTER TOPSOILS, ETC. HAVE BEEN REMOVED FROM THE SITE WITHIN AND TO A POINT 10' OUTSIDE THE
BUILDING CONSTRUCTION AREA, THE UPPER 24" OF EXPOSED SOILS SHALL BE COMPACTED TO A MINIMUM
DENSITY OF 95% MODIFIED PROCTOR MAXIMUM DRY DENSITY (ASTM D1557) BY PROOFROLLING WITH A FULLY
LOADED PNEUMATIC TIRED TANDEM AXLE DUMP TRUCK CAPABLE OF TRANSFERRING A LOAD OF 10 TO 20 TONS
BY OVERLAPPING PASSES. A MINIMUM OF 8 COMPLETE PASSES SHALL BE MADE WITHIN THE BUILDING AREA.
3. PROOFROLLING SHALL BE PERFORMED UNDER THE OBSERVATION OF AN APPROVED TESTING LABORATORY
SUPERVISED BY A GEOTECHNICAL ENGINEER. UNDERCUT, BACKFILL, AND COMPACT AREAS WHICH PUMP,
DEFLECT, OR RUT EXCESSIVELY OR WHICH DO NOT STABILIZE AFTER SUCCESSIVE PASSES OF PROOFROLLING
EQUIPMENT.
4. AFTER COMPLETION OF DENSIFICATION OF EXISTING SOILS, PLACE STRUCTURAL FILL FOR BUILDING AND
PAVEMENT AREAS IN THIN (8" TO 10") LIFTS COMPACT TO A MINIMUM DENSITY OF 95% MODIFIED PROCTOR
MAXIMUM DRY DENSITY (ASTM D1557). MATERIAL USED AS STRUCTURAL FILL SHALL BE NON-PLASTIC
GRANULAR MATERIAL CONTAINING LESS THAN 15% FINES PASSING THROUGH THE NO. 200 SIEVE AND FREE OF
ORGANICS, BOULDERS, OR OTHER DELETERIOUS MATERIALS.
SLAB ON GRADE
1. APPLY AN APPROVED CURING COMPOUND CONFORMING TO ASTM C309 AFTER FINISHING THE SLAB.
2. ALL WELDED WIRE FABRIC SHALL BE IN ACCORDANCE WITH ASTM A185. LAP ADJOINING PIECES AT LEAST
ONE FULL MESH OR 8" MINIMUM. UNLESS OTHERWISE APPROVED, ALL WELDED WIRE FABRIC SHALL BE
BLOCKED INTO POSITION INDICATED WITH PRECAST CONCRETE BLOCKS HAVING A COMPRESSIVE STRENGTH
EQUAL TO THAT OF THE SLAB.
3. THE USE OF POLYPROPYLENE FIBERS (IN LIEU OF WELDED WIRE FABRIC) IS PROHIBITED WITHOUT THE
WRITTEN AUTHORIZATION OF THE ENGINEER.
4. THE MAXIMUM SPACING OF JOINTS SHALL BE 15' OR AS SHOWN ON PLANS.
5. ALL POROUS FILL MATERIAL SHALL BE A CLEAN GRANULAR MATERIAL WITH 100% PASSING 1 1
2" SIEVE AND
NO MORE THAN 5% PASSING A NO. 4 SIEVE. POROUS FILL SHALL BE COMPACTED TO 95% MODIFIED
PROCTOR. DRY DENSITY PER ASTM D1557.
6. SLAB JOINTS SHALL BE FILLED WITH APPROVED MATERIAL. THIS SHOULD TAKE PLACE AS LATE AS POSSIBLE,
PREFERABLY 4 TO 6 WEEKS AFTER THE SLAB HAS BEEN CAST. PRIOR TO FILLING, REMOVE ALL DEBRIS FROM
THE SLAB JOINTS, THEN FILL IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS.
7. SEE THE ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONS OF DEPRESSED SLAB AREAS AND DRAINS. SLOPE
SLAB TO DRAINS WHERE SHOWN.
8. THE FINISH TOLERANCE OF ALL SLABS SHALL BE IN ACCORDANCE WITH ACI 301, TYPE A.
9. WALKWAYS AND OTHER EXTERIOR SLABS ARE NOT INDICATED ON THE STRUCTURAL DRAWINGS. SEE THE
SITE PLAN AND ARCHITECTURAL DRAWINGS FOR LOCATIONS, DIMENSIONS, ELEVATIONS, JOINTING DETAILS
AND FINISH DETAILS.
10. CONTROL JOINT SEALANT SHALL BE SIKADUR 51 NS/SL OR APPROVED EQUAL. EXPANSION AND ISOLATION
JOINT SEALANT SHALL BE SIKAFLEX 1a OR APPROVED EQUAL.
REINFORCING STEEL
1. ALL REINFORCING STEEL SHALL BE ASTM A615, GRADE 60, UNLESS NOTED OTHERWISE.
2. ALL WELDED WIRE FABRIC SHALL BE ASTM A185, 70 KSI MINIMUM YIELD STRENGTH.
3. ADDITIONAL REINFORCING AND THAT QUANTITY OF REINFORCING OCCURRING AT OPENINGS SHALL
BE PLACED EQUALLY EACH SIDE OF OPENINGS AS DETAILED.
4. HOOKS IN REINFORCING ARE IN ADDITION TO LENGTH SHOWN.
5. REINFORCING IS TO BE SUPPORTED IN FORMS AND SPACED WITH WIRE BAR SUPPORTS ACCORDING
TO CRSI "PLACING REINFORCING BARS" UNLESS NOTED OTHERWISE.
6. MINIMUM REINFORCING STEEL CLEAR COVERS ARE AS FOLLOWS:
A. CONCRETE CAST DIRECTLY AGAINST EARTH - 3"
B. INTERIOR SLABS -1"
C. INTERIOR BEAMS AND COLUMNS -1 1/2"
D. EXTERIOR BEAMS AND COLUMNS -2"
E. EXTERIOR SLABS -1 1/2"
7. UNLESS NOTED OTHERWISE, ALL BAR REINFORCING LAP SPLICES SHALL HAVE A MINIMUM LAP LENGTH
OF 48 BAR DIAMETERS.
PLYWOOD / GYPBOARD SHEATHING
1. ALL PLYWOOD CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE AMERICAN PLYWOOD ASSOCIATION (APA)
SPECIFICATIONS.
2. ALL ROOF PANEL SHEATHING SHALL BE PER PLAN. SUITABLE EDGE SUPPORT SHALL BE PROVIDED BY THE USE OF PANEL
CLIPS OR BLOCKING BETWEEN FRAMING.
3. ALL FLOOR SHEATHING SHALL BE TONGUE & GROOVE PER PLAN. FIELD-GLUE USING ADHESIVES MEETING APA
SPECIFICATIONS AFG-01, APPLIED IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS.
4. ALL WALL PANEL SHEATHING SHALL BE PER PLAN.
5. INSTALL ALL PLYWOOD SHEATHING AT FLOOR AND ROOF WITH THE LONG DIMENSIONS OF THE PANEL ACROSS SUPPORTS
AND WITH PANEL CONTINUOUS OVER TWO OR MORE SPANS. STAGGER PANEL END JOINTS. ALLOW 1/8" SPACING AT
PANEL ENDS AND EDGES UNLESS OTHERWISE RECOMMENDED BY THE SHEATHING MANUFACTURER.
6. ALL NAILS SHALL NOT BE OVERDRIVEN.
7. ALL EXISTING WALLS SHALL BE SHEATHED PER PLAN.
8. PROVIDE BLOCKING AT UNSUPPORTED PANEL EDGES AS FOLLOWS:
ROOFS AND FLOORS - ONLY WHERE INDICATED ON PLAN
WALLS - FULLY BLOCKED
9. WHERE EITHER 2" OR 212" FASTENER SPACINGS ARE USED FOR WOOD STRUCTURAL PANELS USED AT ROOF OR FLOOR,
THE FRAMING MEMBER AT THE ADJOINING PANEL SHALL BE 3" NOMINAL WIDTH AND THE NAILS AT PANEL EDGES SHALL
BE STAGGERED IN TWO LINES.
10. ALL PLYWOOD AND SHEATHING SHALL BE APA RATED, BEAR THE STAMP OF AN APPROVED TESTING AGENCY, AND SHALL
BE FABRICATED WITH EXTERIOR GLUE. NAILS AT ABUTTING PLYWOOD EDGES MUST PENETRATE THE SAME PIECE OF
FRAMING OR BLOCKING.
11. PERIMETER OF ANY OPENINGS SHALL BE FASTENED AS BOUNDARY NAILING.
12. OPENINGS WITH A DIMENSION PERPENDICULAR TO THE JOISTS GREATER THAN 4'-0" SHALL BE BLOCKED BEYOND THE
HEADERS, AND METAL TIES NOT LESS THAN 16 GAGE BY 11
2" WIDE WITH (8)-16d COMMON NAILS ON EACH SIDE OF THE
HEADER-JOIST INTERSECTION SHALL BE PROVIDED.
13. AT SHEAR WALLS OR DRAG STRUTS, THE PLYWOOD DIAPHRAGM MUST BE NAILED TO TOP PLATES, MEMBERS, BLOCKING,
ETC. AS FOLLOWS:
EXTERIOR WALLS/ DIAPHRAGM EDGES: 1x BOUNDARY NAILING
INTERIOR WALL LINES:2x BOUNDARY NAILING
FOUNDATIONS
1. ALL FOUNDATION FILL SUBGRADE SOILS SHALL BE COMPACTED AS FOLLOWS: (REF. ASTM D1557)
A. 95% MODIFIED PROCTOR FOR GREATER THAN 18" BELOW FINAL FILL.
B. 98% MODIFIED PROCTOR FOR THE UPPER 18" BENEATH BUILDINGS AND PAVEMENTS.
2. SOILS TESTING LABORATORY SHALL CONDUCT COMPACTION TESTS IN ACCORDANCE WITH ASTM D6938.
RATE OF COMPACTION SHALL BE AS FOLLOWS:
A. ONE TEST FOR EACH SPREAD FOOTING;
B. ONE TEST FOR EACH 50 LINEAR FEET OF CONTINUOUS FOOTING;
C. ONE TEST FOR EACH 1000 S.F. OF SLAB.
3. FOUNDATIONS HAVE BEEN DESIGNED FOR 1,500 PSF MINIMUM ALLOWABLE SOIL BEARING PRESSURE.
4. REMOVE ALL WATER SOFTENED SOILS FROM FOOTING EXCAVATIONS PRIOR TO PLACING CONCRETE. FILL
REMAINING VOIDS WITH ADDITIONAL CONCRETE.
5. SUPPORT ALL BOTTOM REINFORCEMENT IN FOUNDATION WITH STANDEES OR WHOLE CONCRETE BRICKS AT
48" O.C. MAX. REQUIRED CONCRETE COVER SHALL BE MAINTAINED AT ALL TIMES.
6. ALL FOOTING, PIER, AND OTHER FOUNDATION REINFORCING SHALL BE TIED IN PLACE PRIOR TO POURING
CONCRETE.
7. WHERE FINISHED GRADES DIFFER ON OPPOSITE SIDES OF FOUNDATION WALLS, PROVIDE TEMPORARY
BRACING. PREVENT LATERAL MOVEMENT UNTIL ALL ADJACENT FILLING, COMPACTION, FLOOR SLABS, AND
FRAMING AT NEXT LEVEL OVER HAS BEEN COMPLETED.
8. UNLESS INDICATED ON FOUNDATION PLAN, VERTICAL STEPS IN FOOTINGS TO BE MAXIMUM 2'-0" VERTICAL
SPACED NO LESS THAN 4'-0" O.C. HORIZONTALLY TO MAINTAIN MINIMUM 12" COVER BELOW FINISHED EARTH
GRADE.
9. WHERE GRAVITY PLUMBING LINES OCCUR BELOW TOP OF WALL FOOTING, STEP FOOTING DOWN TO PROVIDE
CLEARANCES INDICATED ON PLANS. COORDINATE WITH PLUMBING DRAWINGS FOR LOCATIONS, SIZES, AND
INVERTS.
10. CONSTRUCTION JOINTS IN CONTINUOUS FOOTINGS TO BE FORMED VERTICALLY IN ACCORDANCE WITH
FOUNDATION DETAILS IN PLANS.
11. PROVIDE 1/2" EXPANSION JOINT FILLER AROUND PERIMETER OF SLABS WHERE THEY ABUT VERTICAL
SURFACES AND AT COLUMN ISOLATION JOINTS AS DETAILED.
STRUCTURAL STEEL
1. APPLICABLE STRUCTURAL STEEL CODES:
A. AISC SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS, 15TH EDITION
B. AISC CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS AND BRIDGES
2. MATERIALS:
"W" SHAPES -ASTM A992, GRADE 50
STEEL TUBING - ASTM A500, GRADE B, Fy = 46 KSI
STEEL PIPE -ASTM A500, GRADE B, Fy = 42 KSI
ALL OTHER -ASTM A36
ANCHOR BOLTS - ASTM A307
HIGH STRENGTH BOLTS - ASTM A325
ANCHOR RODS - ASTM F1554, GRADE 36
WELDING ELECTRODES - E70 SERIES
3. STRUCTURAL STEEL SHALL BE FABRICATED AND ERECTED ACCORDING TO THE LATEST EDITION OF AISC "SPECIFICATION, DESIGN, AND
ERECTION OF STRUCTURAL STEEL FOR BUILDINGS" AND RELATED PUBLICATIONS SPECIFIED THEREIN.
4. ALL SHEAR AND TENSION TYPE BOLTED CONNECTIONS SHALL BE MADE WITH 3/4" DIAMETER ASTM A325N HIGH STRENGTH BOLTS.
DESIGN TORQUE TO BE DEVELOPED USING LOAD INDICATOR WASHERS AS MANUFACTURED BY BETHLEHEM STEEL CORPORATION OR
APPROVED EQUIVALENT. INSTALL AS PER MANUFACTURER'S PUBLISHED INSTRUCTIONS. ALL OTHER BOLTED CONNECTIONS MAY BE
MADE WITH ASTM A307 BOLTS AND WASHERS.
5. STEEL FRAMING ERECTION INCLUDING ALL BOLTED AND WELDED CONNECTIONS, BRACING, AND ANCHORAGES SHALL BE COMPLETED
AND PLUMB PRIOR TO PLACEMENT OF DECK.
6. NON-SHRINK, NON-METALLIC GROUT WITH A 28 DAY COMPRESSIVE STRENGTH OF 5000 PSI SHALL BE USED UNDER BASE PLATES.
7. ENGINEER SHALL BE CONTACTED FOR APPROVAL OF ANY FIELD MODIFICATIONS OF ANCHOR BOLTS OR RODS AND COLUMN BASE PLATES.
8. TEMPORARY BRACING OF STEEL STRUCTURAL ELEMENTS IS THE RESPONSIBILITY OF THE CONTRACTOR. STRUCTURAL STABILITY SHALL
BE MAINTAINED AT ALL TIMES DURING THE ERECTION PROCESS.
9. FRAMING CONNECTIONS NOT DETAILED, OR CONNECTIONS THAT ARE MODIFIED FROM THOSE DETAILED SHALL BE DESIGNED BY
SUPPLIER FOR THE END REACTION SHOWN ON THE PLAN. IF NO REACTION IS PROVIDED, CONNECTIONS SHALL BE DESIGNED FOR 1/2
THE BEAM MAXIMUM UNIFORM LOAD PER AISC MANUAL FOR STEEL CONSTRUCTION.
10. SHOP CONNECTIONS SHALL BE WELDED OR HIGH STRENGTH BOLTED. USE 3/16" FILLET WELD MINIMUM.
11. FIELD CONNECTIONS SHALL BE WELDED OR HIGH STRENGTH BOLTED AS DETAILED. NO FIELD WELDING OF HOT-DIPPED GALVANIZED
MEMBERS IS ALLOWED. USE 3/16" FILLET WELD MINIMUM.
12. CONTRACTOR SHALL SUBMIT THE FOLLOWING FOR REVIEW:
A. SHOP DRAWINGS OF STEEL DETAILS PRIOR TO FABRICATING STRUCTURAL STEEL.
B. STRUCTURAL DESIGN CALCULATIONS AND MEMBERS SIZES FOR ALL STAIR MEMBERS AND CONNECTIONS NOT SHOWN HEREIN.
C.
STRUCTURAL STEEL CALCULATIONS AND MEMBER SIZES FOR ALL STAIR MEMBERS AND CONNECTIONS NOT SHOWN HEREIN.
D. ERECTION DRAWINGS FOR ALL STAIR MEMBERS SIGNED AND SEALED BY A REGISTERED ENGINEER IN THE STATE APPLICABLE TO
THE PROJECT.
E. ERECTION DRAWINGS FOR ALL STAIR MEMBERS SIGNED AND SEALED BY A REGISTERED ENGINEER IN THE STATE APPLICABLE TO
THE PROJECT.
13. ALL BRICK SHELF ANGLES SHALL BE HOT-DIPPED GALVANIZED.
14.
ALL EXTERIOR ELEMENTS AND THOSE ELEMENTS NOTED TO BE GALVANIZED SHALL BE HOT-DIPPED GALVANIZED IN ACCORDANCE WITH
ASTM A123 AFTER SANDBLAST CLEANING PER SSPC-SP10. USE ASTM A325 BOLTS HOT DIPPED GALVANIZED WITH GALVANIZED
HARDENED WASHERS AND GALVANIZED HEAVY HEX NUTS FOR BOLTING OF GALVANIZED ITEMS.
15. STEEL COLUMNS, BASE PLATES, AND ALL STEEL BELOW GRADE SHALL HAVE A MINIMUM 3" CONCRETE COVER PROTECTION.
16. ALL SHOP AND FIELD WELDS SHALL BE PERFORMED BY A CERTIFIED WELDER IN ACCORDANCE WITH AWS D1.1.
17. A GAS CUTTING TORCH SHALL NOT BE USED FOR CUTTING HOLES OR CORRECTING MANUFACTURING ERRORS IN THE FIELD WITHOUT
THE WRITTEN CONSENT OF THE ENGINEER OF RECORD FOR EACH OCCURRENCE.
18. STANDARD BRICK LINTELS:
SPANS
<2'-0": 1-BAR 2 1/2 x3/8 FOR EACH 4" WYTHE
2'-0" - 5'-0":1-L3 1/2 x 3 1/2 x 5/16 FOR EACH 4" WYTHE
5'-0" - 6'-0":1-L4 x 3 1/2 x 5/16 FOR EACH 4" WYTHE (LLV)
6'-0" - 8'-0":1-L5 x 3 1/2 x 5/16 FOR EACH 4" WYTHE (LLV)
8'-0" - 10'-0":1-L6 x 3 1/2 x 5/16 FOR EACH 4" WYTHE (LLV)
A. MINIMUM 6" BEARING EACH END. INCREASE EACH BEARING LENGTH 1" FOR EACH FOOT OF SPAN OVER 6'-0"
B. INCREASE WIDTH OF HORIZONTAL LEG WHERE REQUIRED TO COVER WALL CAVITY ABOVE. SEE ARCHITECTURAL
DETAILS.
CONCRETE MASONRY
1. APPLICABLE MASONRY CODES:
A. TMS 402-2016 BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES.
B. TMS 602-2016 SPECIFICATIONS FOR MASONRY STRUCTURES.
2. CONCRETE MASONRY UNITS SHALL BE LOAD BEARING TYPE CONFORMING TO ASTM C90 HAVING A MINIMUM COMPRESSIVE
STRENGTH OF 2000psi.
3. ALL CELLS BELOW GRADE SHALL BE FILLED SOLID WITH GROUT OR CONCRETE.
4. MORTAR SHALL CONFORM TO ASTM C270 TYPE S.
5. REINFORCED WALLS, STIFFENERS, PIERS, ETC. SHALL BE FILLED IN MAXIMUM OF 4'-0" LIFTS. FILL SHALL BE
MECHANICALLY MIXED (ASTM C476 COURSE) GROUT OR REGULAR WEIGHT CONCRETE (ASTM C94) WITH MAX 1/2" COARSE
AGGREGATE HAVING NOT LESS THAN 3,000psi (MIN.) 28 DAY STRENGTH. SEE SPECIFICATIONS.
6. PLAIN END TWO CELL UNITS SHALL BE USED FOR BLOCKS THAT ARE TO HAVE CELLS REINFORCED OR FILLED. WEB SHELLS
ADJACENT TO CELLS THAT ARE TO BE FILLED ARE TO BE BEDDED IN MORTAR.
7. FILL CELLS AS NOTED ON DRAWINGS WITH 3000psi GROUT CONFORMING TO ASTM C476 SPECIFICALLY DESIGNED FOR
FILLING CELLS.
8. VERTICAL REINFORCING TO BE LAPPED 48 BAR DIAMETERS AT DOWELS AND SPLICES.
9. HORIZONTAL JOINT REINFORCING TO BE CONTINUOUS THROUGH REINFORCED CELLS.
10. PROVIDE 9 GA. GALVANIZED WIRE TRUSS OR LADDER TYPE HORIZONTAL JOINT REINFORCING CONFORMING TO ASTM A82
AT 16" O.C. OR AS INDICATED ON DRAWINGS.
11. SEE ARCHITECTURAL DRAWINGS FOR THE EXTENT AND EXACT LOCATION OF MASONRY WALLS.
12. WALL CONTROL JOINTS SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE FOLLOWING:
A. WALL CONTROL JOINTS SHALL BE PROVIDED IN ALL CONCRETE MASONRY WALLS AT LOCATIONS INDICATED
ON THE STRUCTURAL DRAWINGS BUT AT A SPACING NOT GREATER THAN 24'-0" O.C.
B. HORIZONTAL JOINT REINFORCING SHALL BE INTERRUPTED AT EACH SIDE OF WALL CONTROL JOINTS
C. WALL CONTROL JOINTS SHALL NOT BE PLACED OVER OPENINGS OR WITHIN JAMB WIDTH
13. BLOCK LINTELS SHALL BE SPECIALLY FORMED U-BLOCK LINTEL OR LOW WEB LINTEL UNITS WITH REINFORCEMENT AS
SHOWN OR PRECAST UNITS DESIGNED FOR THE WEIGHT OF MASONRY ABOVE AND ALL OTHER APPLIED LOADS.
14. UNLESS NOTED OTHERWISE, PROVIDE CONTINUOUS 8" DEEP INTERMEDIATE BOND BEAMS AT MAXIMUM 8'-0" O.C.
VERTICALLY. REINFORCE WITH (2) #5 CONTINUOUS BARS OR AS NOTED ON THE PLANS. INTERRUPT AT VERTICAL
CONTROL JOINTS. PROVIDE BOND BEAM AT TOP OF ALL CMU WALLS.
15. PROVIDE (2) #5x24"x24" HORIZONTAL CORNER BARS AT CHANGES IN DIRECTION OF BOND BEAM. WHERE BOND BEAMS
INTERRUPTED BY OPENINGS, HOOK 12" INTO REINFORCED JAMB.
16. UNLESS NOTED OTHERWISE, REINFORCED PIERS AT JAMBS OF OPENINGS SHALL BE DISCONTINUOUS ABOVE LINTEL
BEARING EXCEPT AS FOLLOWS:
OPENING 4'-0" TO 8'-0": CONTINUE JAMB REINFORCING 24" ABOVE OPENING
OPENING OVER 8'-0": CONTINUE JAMB REINFORCING TO TOP OF WALL
17. ALL MASONRY WALLS SHOWN ON THESE STRUCTURAL DRAWINGS HAVE BEEN DESIGNED TO RESIST THE REQUIRED
VERTICAL AND LATERAL FORCES IN THE FINAL CONFIGURATION ONLY. IT IS THE SOLE RESPONSIBILITY OF THE
CONTRACTOR TO ADEQUATELY BRACE THE WALLS FOR VERTICAL AND LATERAL LOADS THAT COULD POSSIBLY BE APPLIED
PRIOR TO COMPLETION OF LATERAL SUPPORT BY CONNECTIONS AT FLOOR OR ROOF FRAMING LOCATIONS.
18. UNLESS SHOWN OTHERWISE IN WALL DETAILS, PLACE ONE VERTICAL #5 BAR IN FULLY GROUTED CELL @ 48" O.C.
MINIMUM ALONG THE LENGTH OF WALLS. VERTICAL BARS TO EXTEND FROM FOOTING DOWEL BAR SPLICE TO TOP OF
WALL AND SHALL PENETRATE INTO THE BOTTOM OF BOND BEAMS AT TOP OF WALL OR PARAPET 4" MINIMUM.
19. UNLESS SHOWN OTHERWISE, ONE VERTICAL #5 BAR IN A FULLY GROUTED CELL SHALL BE PLACED AT WALL CORNERS, AT
THE ENDS OF WALLS, ON EACH SIDE OF DOORS AND WINDOW JAMBS, AND ON EACH SIDE OF MASONRY CONTROL JOINTS.
VERTICAL BARS TO EXTEND FROM FOOTING DOWEL BAR SPLICE TO THE TOP OF WALL AND SHALL PENETRATE INTO THE
BOTTOM OF BOND BEAMS AT TOP OF WALL OR PARAPET 4" MINIMUM.
20. STANDARD BRICK LINTELS:
SPANS < 2'-0": 1-BAR 2 1/2 x3/8 FOR EACH 4" WYTHE
2'-0" - 5'-0":1-L3 1/2 x 3 1/2 x 5/16 FOR EACH 4" WYTHE
5'-0" - 6'-0":1-L4 x 3 1/2 x 5/16 FOR EACH 4" WYTHE (LLV)
6'-0" - 8'-0":1-L5 x 3 1/2 x 5/16 FOR EACH 4" WYTHE (LLV)
8'-0" - 10'-0":1-L6 x 3 1/2 x 5/16 FOR EACH 4" WYTHE (LLV)
A. MINIMUM 6" BEARING EACH END. INCREASE EACH BEARING LENGTH 1" FOR EACH FOOT OF SPAN OVER 6'-0"
B. INCREASE WIDTH OF HORIZONTAL LEG WHERE REQUIRED TO COVER WALL CAVITY ABOVE. SEE
ARCHITECTURAL DETAILS.
SHEET TITLE
PROJECT No.
DATE
REV.
No.DATENARRATIVE
0ISSUED FOR
PERMIT
MEMORY MATTERS
RENOVATION AND ADDITION
15 TRELLIS COURT
HILTON HEAD ISLAND,
SOUTH CAROLINA
26-562
06-05-2026
SHEET No.
STRUCTURAL DESIGN CONSULTANTS
S100
No. 7089
SOUTH
CAROLINA
SHEARLOCK
ENGINEERING,
LLC
CE
NOITA
RI TFICATE
ZIRO
OF
HT
AU
06-05-2026
1
UPDATED PER
EXISTING
CONDITIONS
07-21-2026
ENGINEERED WOOD TRUSSES
1. WOOD TRUSSES SHALL BE DESIGNED BY THE MANUFACTURER IN ACCORDANCE WITH THE APPLICABLE PROVISIONS OF
THE LATEST EDITION OF THE NATIONAL DESIGN SPECIFICATIONS OF THE NATIONAL FOREST PRODUCTS ASSOCIATION,
THE DESIGN SPECIFICATIONS FOR LIGHT METAL PLATE CONNECTED WOOD TRUSSES OF THE TRUSS PLATE INSTITUTE AND
INTERNATIONAL BUILDING CODE.
2. ALL TRUSSED RAFTERS SHALL BE DESIGNED, FABRICATED, AND ERECTED TO SUPPORT THE FOLLOWING MINIMUM LOADS:
LIVE - TOP CHORD = 20 PSF
DEAD - TOP CHORD = 15 PSF
DEAD - BOTTOM CHORD = 15 PSF + MECHANICAL EQUIPMENT
3. WOOD MATERIALS SHALL BE SOUTHERN PINE, DOUGLAS FIR OR LARCH AND SHALL BE KILN DRIED AND USED AT 19%
MAXIMUM MOISTURE CONTENT. PROVIDE GRADE NO. 2 OR AS REQUIRED TO SATISFY STRESS REQUIREMENTS.
4. PROVIDE AT EACH SUPPORT GALVANIZED METAL HURRICANE PLATE ANCHORAGES SUFFICIENT TO RESIST HORIZONTAL
AND VERTICAL WIND COMPONENTS WITH A SAFETY FACTOR OF 3. MINIMUM UPLIFT LOAD AS DETERMINED BY TRUSS
MANUFACTURER FROM REQUIREMENTS OF LOCAL BUILDING CODES.
5. THE CONTRACTOR SHALL PROVIDE ALL TEMPORARY AND PERMANENT BRACING AS REQUIRED FOR SAFE ERECTION AND
PERFORMANCE OF THE TRUSSES. THE GUIDELINES SET FORTH BY THE TRUSS PLATE INSTITUTE PUBLICATION "HIB-91,
COMMENTARY AND RECOMMENDATIONS FOR HANDLING, INSTALLING AND BRACING METAL PLATE CONNECTED WOOD
TRUSSES" SHALL BE A MINIMUM REQUIREMENT.
6. SHOP DRAWINGS, COMPUTATIONS, ETC. TO BE SUBMITTED FOR REVIEW. SHOP DRAWINGS SHALL PROVIDE ERECTION
LAYOUT FOR TRUSS RAFTERS, OUTRIGGERS, HEADERS, BRACING, ETC. SEE ARCHITECTURAL AND STRUCTURAL PLANS FOR
SUPPORT LOCATIONS.
7. CALCULATIONS AND DRAWINGS SHALL BEAR THE SEAL OF A PROFESSIONAL ENGINEER LICENSED IN THE STATE IN WHICH
THE PROJECT IS BEING CONSTRUCTED.
8. TRUSS WEB TO CHORD CONNECTION SHALL BE MADE WITH APPROVED GALVANIZED STEEL TRUSS CONNECTION PLATES
MEETING ALL REQUIREMENTS OF THE TRUSS PLATE INSTITUTE.
9. TRUSS MEMBERS AND COMPONENTS SHALL NOT BE CUT, NOTCHED, DRILLED NOR OTHERWISE ALTERED IN ANY WAY
WITHOUT WRITTEN APPROVAL OF THE ENGINEER.
10. ALL TRUSS RAFTERS SHALL MEET THE FOLLOWING MINIMUM STRESS GRADES
TOP CHORDS.......................SYP #2 KD MG
BOTTOM CHORDS................SYP #2 KD MG
WEB MEMBERS....................SYP #2 KD
OTHER................................SYP #2 KDNOTE: THIS STRUCTURAL DESIGN INCLUDES THE RENOVATION OF AN EXISTING BUSINESS AND ADDITION OF
A FOUR SEASONS ROOM AND CONNECTING BREEZEWAY. NEW CONCRETE RAMPS AND STAIRS AT ENTRYWAYS
AND COVERED CANOPIES ARE ALSO INCLUDED ADDITIONS. SHEARLOCK ENGINEERING, LLC (SLE) ASSUMES
THE EXISTING FOUNDATION AND FRAMING IS SOUND AND HAS BEEN DESIGNED IN ACCORDANCE WITH
APPLICABLE IBC AND LOCAL BUILDING CODES AT THE TIME OF CONSTRUCTION. DEMOLITION IS SOLELY THE
RESPONSIBILITY OF THE CONTRACTOR. SLE IS NOT RESPONSIBLE FOR MEANS AND METHODS OF
CONSTRUCTION OR FINISH / STRUCTURAL ISSUES THAT MAY ARISE DURING CONSTRUCTION.
PER 2021 IBC 102.7.1, ALL ADDITIONS, ALTERATIONS, AND REPAIRS OF THIS STRUCTURE ARE DESIGNED IN
COMPLIANCE WITH CURRENT CODE REQUIREMENTS.
DIMENSIONAL LUMBER FRAMING
1. ALL STRUCTURAL LUMBER DESIGN SHALL CONFORM TO THE REQUIREMENTS OF THE NATIONAL DESIGNS SPECIFICATION FOR
WOOD CONSTRUCTION (NDS-2018).
2. LOCATION, NUMBER, AND DIMENSIONS OF FRAMING MEMBERS SHOW GENERAL ARRANGEMENT ONLY. ACTUAL SPANS,
SPACING, ETC. SHALL BE DETERMINED FROM ARCHITECTURAL DETAILS.
3. SEE ARCHITECTURAL PLANS AND DETAILS FOR EDGE SECTIONS, HEADER AND LINTEL LOCATIONS, AND ALL NON-STRUCTURAL
FRAMING AND TRIM.
4. ALL WOOD FRAMING MATERIAL SHALL BE SURFACED DRY AND USED AT 19% MAXIMUM MOISTURE CONTENT. ALLOWABLE
STRESS REQUIREMENTS OF ALL MATERIALS SHALL BE IN ACCORDANCE WITH THE "SCHEDULE OF REQUIRED STRESS VALUES".
5. ALL STUD AND WALL FRAMING SHALL BE NO. 2 GRADE SOUTHERN YELLOW PINE (SYP). "STUD" GRADE MATERIAL IS STRICTLY
PROHIBITED FROM USE.
6. ALL JOIST, RAFTER & MISC. FRAMING SHALL BE NO. 2 GRADE, SOUTHERN YELLOW PINE. PROVIDE FULL-DEPTH BLOCKING AT
ENDS. PROVIDE FULL-DEPTH (OR METAL) BRIDGING AT MIDSPAN AND AT A MAXIMUM SPACING OF 8'-0" O.C. IN BETWEEN.
7. ALL LUMBER EXPOSED TO EXTERIOR ENVIRONMENT OR IN CONTACT WITH MASONRY OR CONCRETE SHALL BE PRESSURE
TREATED TO A MINIMUM RETENTION OF 0.25 lbs. OF ACQ PER CUBIC FOOT OF WOOD, AND EACH PIECE SHALL BEAR THE
THIRD PARTY QUALITY MARK, "ABOVE GRADE USE". ALL LUMBER IN CONTACT WITH THE GROUND SHALL BE PRESSURE
TREATED TO A MINIMUM RETENTION OF 0.40 lbs. OF ACQ PER CUBIC FOOT OF WOOD, AND EACH PIECE SHALL BEAR THE
THIRD PARTY QUALITY MARK, "GROUND CONTACT USE". REFERENCE AWPA STANDARD U1 TO THE REQUIREMENTS OF USE
CATEGORY 4 (UC4B) AND ASTM D1760 FOR PRESSURE TREATMENT OF TIMBER PRODUCTS.
8. WHERE POSSIBLE ALL CUTS AND HOLES SHOULD BE COMPLETED BEFORE TREATMENT. CUTS AND HOLES DUE TO ON-SITE
FABRICATION SHALL BE BRUSHED WITH 2 COATS OF COPPER NAPHTHENATE SOLUTION CONTAINING A MINIMUM OF 2%
METALLIC COPPER IN SOLUTION (PER AWPS STANDARD M4).
9. THE CONTRACTOR SHALL CAREFULLY SELECT LUMBER TO BE USED IN LOAD BEARING APPLICATIONS. THE LENGTH OF SPLIT
ON THE WIDE FACE OF 2" NOMINAL LOAD BEARING FRAMING SHALL BE LIMITED TO LESS THAN ½ OF THE WIDE FACE
DIMENSION. THE LENGTH OF SPLIT ON THE WIDE FACE OF 3" (NOMINAL) AND THICKER LUMBER SHALL BE LIMITED TO HALF
OF THE NARROW FACE DIMENSIONS.
10. ALL WOOD JOISTS AND HEADERS WHICH FRAME INTO BEAMS SHALL BE SUPPORTED BY SIMPSON LUS HANGERS WITH THE
SAME WIDTH AND DEPTH OF THE MEMBER, U.N.O. USE HANGERS WITH CONCEALED FLANGES WHERE THE CONNECTOR
CANNOT BE HIDDEN BY WOOD TRIM OR THE SUPPORT MEMBER IS WIDER THAN THE STANDARD FLANGE.
11. PROVIDE NAILING PATTERN IN COMPLIANCE WITH IBC RECOMMENDED FASTENING SCHEDULE.
12. LOAD BEARING STUD WALLS SHALL BE CONTINUOUSLY BRIDGED AT MID-HEIGHT AND UNSUPPORTED PLYWOOD WALL
SHEATHING JOINTS WITH SOLID WOOD BLOCKING, U.N.O.
13. NO CUTS, HOLES, OR COPES IN STRUCTURAL WOOD FRAMING SHALL BE PERMITTED WITHOUT PRIOR REVIEW AND APPROVAL
BY THE STRUCTURAL ENGINEER AND ARCHITECT.
14. PROVIDE FULL-DEPTH BLOCKING AT ENDS OF RAFTERS AND JOISTS. PROVIDE FULL-DEPTH (OR METAL) BRIDGING AT
MIDSPAN AND AT A MAXIMUM SPACING OF 8'-0" O.C. IN BETWEEN.
15. STRUCTURAL STEEL PLATE CONNECTORS SHALL CONFORM TO ASTM A36 SPECIFICATIONS AND BE ¼" THICK UNLESS
OTHERWISE INDICATED. BOLTS CONNECTING WOOD MEMBERS SHALL BE PER ASTM A307 AND BE 3
4" DIAMETER UNLESS
OTHERWISE INDICATED. PROVIDE WASHERS FOR ALL BOLT HEADS AND NUTS IN CONTACT WITH WOOD SURFACES.
16. BOLT HOLES SHALL BE CAREFULLY CENTERED AND DRILLED NOT MORE THAN 1/16" LARGER THAN THE BOLT DIAMETER.
BOLTED CONNECTIONS SHALL BE SNUG TIGHT BUT NOT TO THE EXTENT OF CRUSHING WOOD UNDER WASHERS.
17. HOLES AND NOTCHES DRILLED OR CUT INTO WOOD FRAMING SHALL NOT EXCEED THE REQUIREMENTS OF IBC, SECTION 23.
18. ALL PLATES, ANCHORS, NAILS, BOLTS, NUTS, WASHERS, AND OTHER MISCELLANEOUS HARDWARE INSTALLED IN PRESSURE
TREATED LUMBER, SHALL BE HOT DIP GALVANIZED.
19. ADEQUATE BRACING SHALL BE PROVIDED UNTIL PERMANENT BRACING AND/OR DIAPHRAGMS ARE INSTALLED.
20. OVERLAP ALL TOP PLATES AT CORNERS.
21. JOINTS IN THE DOUBLE TOP PLATES OF WALLS SHALL BE OFFSET A MINIMUM LAP LENGTH OF 4'-0" & NAILED WITH NOT LESS
THAN (15)-16d FACE NAILS ON EACH SIDE OF THE JOINT.
22. ALL BEAMS SHALL HAVE LATERAL SUPPORT AT THE COMPRESSION EDGE AT A MAXIMUM OF 24" O.C. AND AT BEARING POINTS,
WITH A MINIMUM BEARING LENGTH OF 3 1/2".
23. PROVIDE DOUBLE JOISTS OR SOLID BLOCKING AT 24" O.C. UNDER ALL PARTITIONS AND TO SUPPORT CONCENTRATED LOADS
FROM FRAMING ABOVE UNLESS NOTED OTHERWISE.
24. PROVIDE DOUBLE HEADER BEAMS OF THE SAME SIZE AS JOISTS OR RAFTERS TO FRAME AROUND OPENINGS IN PLYWOOD
DECK UNLESS OTHERWISE INDICATED.
25. PROVIDE DOUBLE LAYER PLYWOOD UNDER ALL CERAMIC OR STONE TILE FLOORS.
26. PROVIDE HEADERS, BRIDGING, CONNECTORS, BLOCKING, TRIMMERS, ETC. AS REQUIRED AND RECOMMENDED BY AITC
TIMBER CONSTRUCTION STANDARDS AND 2021 SCBC U.N.O.
27. WOOD FRAMING MATERIALS:
A. ALL DIMENSIONAL LUMBER SHALL BE #2 SYP KD OR BETTER AND PROVIDE NOT LESS THAN THE FOLLOWING
ALLOWABLE STRESSES:
Fb = 1,000 PSI
Ft = 600 PSI
E = 1,400,000 PSI
Fc = 1,400 PSI
Fcp = 565 PSI
B. SHEATHING:
WALLS..............................................APA RATED SHEATHING, EXPOSURE 1 OR EXTERIOR;
ROOF................................................APA RATED SHEATHING, EXPOSURE1, 2, OR EXTERIOR;
FLOOR..............................................APA RATED STURD-I-FLOOR;
C. ALL BOLTS SHALL BE ASTM A307 WITH WASHERS, GALVANIZED;
D. NAILS IN ACCORDANCE WITH MINIMUM NAILING REQUIREMENTS OF SCBC EXCEPT WHERE NOTED IN DETAILS
OR SPECIFICATIONS. ALL NAILS TO BE GALVANIZED.
CAST-IN-PLACE REINFORCED CONCRETE
1. THE FOLLOWING ACI STANDARDS (LATEST EDITION) APPLY:
A. ACI 318 - CODE
B. ACI 315 - DETAILING
C. ACI 301 - SPECIFICATIONS
D. ACI 304 - PLACING
E. ACI 347 - FORMWORK
F. ACI 211.1 - MIX PROPORTIONING
G. ACI 305 - HOT WEATHER CONCRETING
H. ACI 306 - COLD WEATHER CONCRETING
2. ALL CONCRETE SHALL BE NORMAL WEIGHT CONCRETE (145 PCF) WITH MIXES MEETING THE FOLLOWING
CRITERIA:
STRUCTURAL ELEMENT28 DAY COMPRESSIVE STRENGTH
FOOTINGS, GRADE BEAMS &
FOUNDATION WALLS3,000 PSI
SLAB ON GRADE3,000 PSI
ELEVATED SLABS & BEAMS4,000 PSI
COLUMNS4,000 PSI
3.SLUMP SHALL NOT EXCEED 5". SLUMP TESTS SHALL BE PERFORMED ON EACH TRUCK LOAD AND CONFORM
TO ASTM C143.
No. 33500
REGISTEREDPROFESSIONAL
ENGINEER
SOUTH CAROLINA
JAKE EAVENSON
10/19/2023
07/21/2026
Page 28 of 69
1
S200
DEMOLITION PLAN
SCALE: 1/8" - 1'-0"
DEMOLITION KEY NOTES:
1. G.C. TO VERIFY ALL INTERIOR WALLS TO
BE DEMOLISHED PER ARCH. PLANS ARE
NON-LOAD BEARING AND NOTIFY E.O.R.
OF DISCREPANCIES IN FIELD.
G.C. TO DEMO EXISTING WING
WALL OF RAMP AS REQUIRED FOR
NEW FOOTING AND CMU WALL
DEMOLISH AND REMOVE EXISTING
STAIRS AND LANDING (TYP. OF 2)
DEMOLISH EXISTING INTERIOR
NON-LOADING BEARING WALL
(TYP.) - SEE ARCH.
DEMOLISH EXISTING INTERIOR
NON-LOADING BEARING WALL
(TYP.) - SEE ARCH.
REMOVE EXISTING WINDOW ASSEMBLY
FOR NEW OPENING - EXISTING MASONRY
LINTEL AND JAMBS TO REMAIN
DEMOLISH AND REMOVE EXISTING
ENTRY SLAB TO PREPARE FOR NEW
FOOTINGS AND SLAB
DEMOLITION
PLAN
SHEET TITLE
PROJECT No.
DATE
REV.
No.DATENARRATIVE
0ISSUED FOR
PERMIT
MEMORY MATTERS
RENOVATION AND ADDITION
15 TRELLIS COURT
HILTON HEAD ISLAND,
SOUTH CAROLINA
26-562
06-05-2026
SHEET No.
STRUCTURAL DESIGN CONSULTANTS
S200
No. 7089
SOUTH
CAROLINA
SHEARLOCK
ENGINEERING,
LLC
CE
NOITA
RI TFICATE
ZIRO
OF
HT
AU
06-05-2026
1
UPDATED PER
EXISTING
CONDITIONS
07-21-2026
1
No. 33500
REGISTERED PROFESSIONAL ENGINEER
SOUTH CAROLINA
JAKE EAVENSON
10/19/2023
07/21/2026
Page 29 of 69
#5 @ 24" O.C. F1
MARK W L T
FOOTING SCHEDULE
'A' BARS'B' BARS
1'-0" CONT. 1'-8"(2)-#5 BOTT
W
L
T
3"
(TYP.)
PLAN SECTION
FOOTING DETAIL
"A" BARS
"B" BARS
#5 @ 24" O.C. F21'-0" CONT. 2'-6"(3)-#5 BOTT
F31'-6" 3'-0"(4)-#5 BOTT
(4)-#5 TOP
3'-0"(4)-#5 BOTT
(4)-#5 TOP
F41'-6" 3'-6"(4)-#5 BOTT
(4)-#5 TOP
3'-6"(4)-#5 BOTT
(4)-#5 TOP
F51'-6" 3'-6"(4)-#5 BOTT
(4)-#5 TOP
5'-6"(6)-#5 BOTT
(6)-#5 TOP
FOUNDATION NOTES:
1. CONTRACTOR SHALL COORDINATE ALL FLOOR DRAIN SIZES AND
LOCATIONS WITH ARCHITECTURAL PLANS.
2. AT FLOOR DRAINS, SLOPE FLOOR 12" FOR 2'-0"Ø AREA CENTERED ON
DRAIN. (SEE PLUMBING DRAWINGS) TOP OF DRAIN COVER SHALL BE
FLUSH WITH ADJACENT FLOOR FINISH MATERIAL. WHEN LOCATED IN
CERAMIC TILE FLOOR, GROUT AREA BETWEEN CERAMIC TILE AND
EDGE OF DRAIN. MAINTAIN SLAB THICKNESS AT ALL SLOPES AND
DEPRESSIONS.
3. ALL THICKENED SLABS SHALL BE CENTERED BELOW PROPOSED WALL
ABOVE.
MASONRY NOTES:
1. ALL LOAD BEARING MASONRY WALLS SHALL BE 2000psi (MIN)
8x8x16" OR 12x8x16" UNITS.
2. ALL CELLS SHALL BE GROUTED SOLID W/ 3000psi CONCRETE.
3. VERTICAL REINFORCEMENT SHALL BE #5 BARS @ 24" O.C. IN 8"
MASONRY WALLS.
4. VERTICAL REINFORCEMENT SHALL BE (2) #5 BARS @ 24" O.C. IN 12"
MASONRY WALLS
5. HORIZONTAL REINFORCEMENT SHALL BE W2.8 LADDER STYLE JOINT
REINFORCING @ 16" O.C. VERTICAL.
6. MASONRY BOND BEAMS SHALL BE INSTALLED AT TOP OF WALL IN
ACCORDANCE WITH STRUCTURAL NOTES ON S100.
7. 12" SQ. MASONRY PIERS, SHALL BE GROUTED SOLID W/ 3000 PSI
CONCRETE AND (4) #5 BARS VERTICAL AND #3 TIES @ 8" O.C.
1
S201
FOUNDATION PLAN
SCALE: 1/8" - 1'-0"
5'-6"10'-10"
24'-0"
24'-0"
29'-6"
24'-0"
12" CMU WALL
F2
F2
F2
29'-11" 14'-5"
F1
F1
12'-4"
5'-6"F2
8" CMU WALL (TYP.)
EXISTING TO REMAIN
F3
F3 F3
F5
F4F4F4
F4F4F4 F4
F4
9'-3"9'-3"9'-3"
8" CMU WALL (TYP.)
4'-2"
F1
12" CMU WALL
6'-10"
F4
7'-3"
1'-10"
6'-6" 6'-6"
1'-314"
36'-4"
1
S300
4
S300
F1
3
S300
COLUMN FOUNDATION ATTACHMENT TO
BE DETAILED BY CANOPY MANUFACTURER
AND SUBMITTED TO E.O.R. FOR APPROVAL
PRIOR TO FABRICATION (TYP.)
1'-5"
CMU WALL AT
EXISTING FOUNDATION
SIMILAR TO 3/S300
EXISTING CONCRETE LANDING AND
STAIRS TO REMAIN - G.C. TO VERIFY
CONDITION AND GEOMETRY IN FIELD
5'-2"
5'-0"
12
S300 F5
NOTE: ALL DIMENSIONS ARE
APPROXIMATE. G.C. TO VERIFY
ALL DIMENSIONS IN FIELD.
ANCHOR BOLT NOTES:
1. PROVIDE 5/8"Ø x 10" LONG ANCHOR BOLTS W/ 2"x2"x14" THICK
WASHER SPACED AT 32" O.C. ALONG WALL SILL PLATE AT ALL
EXTERIOR WALLS & AS INDICATED - U.N.O.
PROVIDE (2) BOLTS (MIN.) PER PIECE & 12" MAX FROM EACH END OF
PIECE.
2. PROVIDE 14"x3" TAPCONS @ 24" O.C. (MIN.) AT ALL NEW INTERIOR
NON-LOAD BEARING WALLS.
PROVIDE (2) TAPCONS (MIN.) PER PIECE & 12" MAX FROM EACH END
OF PIECE.
- CONTROL JOINT (C.J.)
- TURNDOWN SLAB
- THICKENED SLAB
- NEW NON-LOAD BEARING WALL
- FOOTING MARK - SEE FOOTING SCHEDULE
- COLUMN MARK - SEE COLUMN SCHEDULE
GENERAL LEGEND
- CMU WALL - SEE MASONRY NOTES
F1
C1
- LOAD BEARING WALL
(2) 2x6 STUD PACK
HSS5x5x12
C1
C2
C3
2
N/A
COLUMN SCHEDULE
COLUMN TYPEMARK
# OF
KING STUDS
AT EACH END
FOR COLUMNS INSTALLED IN WALL FRAMING, THE COLUMN TYPE INDICATES
THE NUMBER AND TYPE OF "JACK STUDS" DIRECTLY SUPPORTING THE BEAM.
ADDITIONAL KING STUDS (IF APPLICABLE) ARE NOTED IN THE LAST COLUMN.
N/A W16x31
FOUNDATION PLAN
SHEET TITLE
PROJECT No.
DATE
REV.
No.DATENARRATIVE
0ISSUED FOR
PERMIT
MEMORY MATTERS
RENOVATION AND ADDITION
15 TRELLIS COURT
HILTON HEAD ISLAND,
SOUTH CAROLINA
26-562
06-05-2026
SHEET No.
STRUCTURAL DESIGN CONSULTANTS
S201
No. 7089
SOUTH
CAROLINA
SHEARLOCK
ENGINEERING,
LLC
CE
NOITA
RI TFICATE
ZIRO
OF
HT
AU
06-05-2026
1
UPDATED PER
EXISTING
CONDITIONS
07-21-2026
No. 33500
REGISTERED PROFESSIONAL ENGINEER
SOUTH CAROLINA
JAKE EAVENSON
10/19/2023
07/21/2026
Page 30 of 69
#5 @ 24" O.C. F1
MARK W L T
FOOTING SCHEDULE
'A' BARS'B' BARS
1'-0" CONT. 1'-8"(2)-#5 BOTT
W
L
T
3"
(TYP.)
PLAN SECTION
FOOTING DETAIL
"A" BARS
"B" BARS
#5 @ 24" O.C. F21'-0" CONT. 2'-6"(3)-#5 BOTT
F31'-6" 3'-0"(4)-#5 BOTT
(4)-#5 TOP
3'-0"(4)-#5 BOTT
(4)-#5 TOP
F41'-6" 3'-6"(4)-#5 BOTT
(4)-#5 TOP
3'-6"(4)-#5 BOTT
(4)-#5 TOP
F51'-6" 3'-6"(4)-#5 BOTT
(4)-#5 TOP
5'-6"(6)-#5 BOTT
(6)-#5 TOP
FOUNDATION NOTES:
1. CONTRACTOR SHALL COORDINATE ALL FLOOR DRAIN SIZES AND
LOCATIONS WITH ARCHITECTURAL PLANS.
2. AT FLOOR DRAINS, SLOPE FLOOR 12" FOR 2'-0"Ø AREA CENTERED ON
DRAIN. (SEE PLUMBING DRAWINGS) TOP OF DRAIN COVER SHALL BE
FLUSH WITH ADJACENT FLOOR FINISH MATERIAL. WHEN LOCATED IN
CERAMIC TILE FLOOR, GROUT AREA BETWEEN CERAMIC TILE AND
EDGE OF DRAIN. MAINTAIN SLAB THICKNESS AT ALL SLOPES AND
DEPRESSIONS.
3. ALL THICKENED SLABS SHALL BE CENTERED BELOW PROPOSED WALL
ABOVE.
MASONRY NOTES:
1. ALL LOAD BEARING MASONRY WALLS SHALL BE 2000psi (MIN)
8x8x16" OR 12x8x16" UNITS.
2. ALL CELLS SHALL BE GROUTED SOLID W/ 3000psi CONCRETE.
3. VERTICAL REINFORCEMENT SHALL BE #5 BARS @ 24" O.C. IN 8"
MASONRY WALLS.
4. VERTICAL REINFORCEMENT SHALL BE (2) #5 BARS @ 24" O.C. IN 12"
MASONRY WALLS
5. HORIZONTAL REINFORCEMENT SHALL BE W2.8 LADDER STYLE JOINT
REINFORCING @ 16" O.C. VERTICAL.
6. MASONRY BOND BEAMS SHALL BE INSTALLED AT TOP OF WALL IN
ACCORDANCE WITH STRUCTURAL NOTES ON S100.
7. 12" SQ. MASONRY PIERS, SHALL BE GROUTED SOLID W/ 3000 PSI
CONCRETE AND (4) #5 BARS VERTICAL AND #3 TIES @ 8" O.C.
17'-0"
35'-0"
6'-0"18'-0"6'-0"
7'-0"
6"
5'-0"
1'-6"
14'-4"5'-0"
T.O.S. = VARIES - SEE ARCH.
4" CONCRETE SLAB ON GRADE
W/ 6x6-W2.1xW2.1 WWF (TYP)
F.F.E. = MATCH EXISTING
4" CONCRETE SLAB ON FILL W/
6x6-W2.1xW2.1 WWF (TYP)
C.J.
C.J.
12'-0"12'-0"
15'-2"8'-1"
4'-312"
T.O.S. NEAR GRADE - SEE ARCH.
4" CONCRETE SLAB ON GRADE
W/ 6x6-W2.1xW2.1 WWF (TYP)
5'-0"
1'-0"
38'-1012"
T.O.S. = VARIES - SEE ARCH.
4" CONCRETE SLAB ON GRADE
W/ 6x6-W2.1xW2.1 WWF (TYP)
G.C. TO SLOPE EXTERIOR
SLAB PER ARCH.
2
S300
1
S202
SLAB PLAN
SCALE: 1/8" - 1'-0"
7'-3"
5'-0"
12" CMU WALL
12" CMU WALL
C3
C3
C2
C3
C3
C2
C2
29'-11"
5'-2"
T.O.S. = VARIES - SEE ARCH.
6" CONCRETE SLAB ON FILL
8" CMU WALL (TYP.) EDGE OF SLAB (TYP.)
EDGE OF SLAB (TYP.)
EDGE OF SLAB (TYP.)
1
S300
C.J.
EQUAL
4
S300
3
S300
6
S300
6
S300
EQUAL
LEVELING SLAB BY G.C. AS
REQUIRED TO MATCH F.F.E.
SERVICE YARD BY OTHERS
NOTE: ALL DIMENSIONS ARE
APPROXIMATE. G.C. TO VERIFY
ALL DIMENSIONS IN FIELD.
5'-0"
4'-2"
EXISTING TO REMAIN
5
S300
TYP.
1'-0"
FRAMING NOTES:
1.ROOF SHEATHING: 15/32" APA-RATED 32/16 MIN. WOOD
STRUCTURAL PANELS MANUFACTURED W/ EXTERIOR-GRADE GLUE &
FASTENED W/ 8d COMMON NAILS (0.131"Øx2.5" LONG) OR
GALVANIZED 8d BOX NAILS (0.113"Øx2.5" LONG) AS FOLLOWS:
NAILING PATTERN:
SUPPORTED EDGES & DIAPHRAGM BOUNDARIES: 6" O.C.
FIELD & INTERMEDIATE SUPPORTS. 6" O.C.
2.ALL EXTERIOR WALLS ARE FRAMED W/ 2x6 @ 16" O.C. - U.N.O.
3.ALL NEW NON-LOAD BEARING WALLS ARE FRAMED W/ 2x4 @ 16"
O.C. - TOP OF WALLS TO BE FASTENED TO EXISTING STEEL JOISTS
PER 13/S400 & 14/S400. BOTTOM OF WALLS FASTENED PER ANCHOR
BOLT NOTES & 5/S300.
4.ALL EXTERIOR WALL SHEATHING AS FOLLOWS (U.N.O.):
15/32" APA-RATED SHEATHING, 32/16 MIN. WOOD STRUCTURAL
PANELS MANUFACTURED AS EXPOSURE 1 & FASTENED
W/ 8d COMMON NAILS (0.131"Øx2.5" LONG) OR GALVANIZED 8d BOX
NAILS (0.113"Øx2.5" LONG) AS FOLLOWS:
NAILING PATTERN:
SUPPORTED EDGES & DIAPHRAGM BOUNDARIES: 3" O.C.
FIELD & INTERMEDIATE SUPPORTS: 12" O.C.
ANCHOR BOLT NOTES:
1. PROVIDE 5/8"Ø x 10" LONG ANCHOR BOLTS W/ 2"x2"x14" THICK
WASHER SPACED AT 32" O.C. ALONG WALL SILL PLATE AT ALL
EXTERIOR WALLS & AS INDICATED - U.N.O.
PROVIDE (2) BOLTS (MIN.) PER PIECE & 12" MAX FROM EACH END OF
PIECE.
2. PROVIDE 14"x3" TAPCONS @ 24" O.C. (MIN.) AT ALL NEW INTERIOR
NON-LOAD BEARING WALLS.
PROVIDE (2) TAPCONS (MIN.) PER PIECE & 12" MAX FROM EACH END
OF PIECE.
- CONTROL JOINT (C.J.)
- TURNDOWN SLAB
- THICKENED SLAB
- NEW NON-LOAD BEARING WALL
- FOOTING MARK - SEE FOOTING SCHEDULE
- COLUMN MARK - SEE COLUMN SCHEDULE
GENERAL LEGEND
- CMU WALL - SEE MASONRY NOTES
F1
C1
- LOAD BEARING WALL
(2) 2x6 STUD PACK
HSS5x5x12
C1
C2
C3
2
N/A
COLUMN SCHEDULE
COLUMN TYPEMARK
# OF
KING STUDS
AT EACH END
FOR COLUMNS INSTALLED IN WALL FRAMING, THE COLUMN TYPE INDICATES
THE NUMBER AND TYPE OF "JACK STUDS" DIRECTLY SUPPORTING THE BEAM.
ADDITIONAL KING STUDS (IF APPLICABLE) ARE NOTED IN THE LAST COLUMN.
N/A W16x31
2
S202
SERVICE YARD SLAB PLAN
SCALE: 1/8" - 1'-0"
10'-8"
8'-0"
EDGE OF SLAB
12" CMU PIER (TYP.) -
SEE MASONRY NOTES
T.O.S. NEAR GRADE - SEE ARCH.
4" CONCRETE SLAB ON GRADE
W/ 6x6-W2.1xW2.1 WWF (TYP)
NOTE: G.C. TO DEFER TO
OWNER/ARCH. FOR LOCATION
AND ORIENTATION OF NEW
SERVICE YARD.
7
S300
NOTE: ALUMINUM LOUVERS FOR
SERVICE YARD PER ARCH. AND
ATTACHED TO STRUCTURE BY G.C.
SLAB PLANS
SHEET TITLE
PROJECT No.
DATE
REV.
No.DATENARRATIVE
0ISSUED FOR
PERMIT
MEMORY MATTERS
RENOVATION AND ADDITION
15 TRELLIS COURT
HILTON HEAD ISLAND,
SOUTH CAROLINA
26-562
06-05-2026
SHEET No.
STRUCTURAL DESIGN CONSULTANTS
S202
No. 7089
SOUTH
CAROLINA
SHEARLOCK
ENGINEERING,
LLC
CE
NOITA
RI TFICATE
ZIRO
OF
HT
AU
06-05-2026
1
UPDATED PER
EXISTING
CONDITIONS
07-21-2026
No. 33500
REGISTERED PROFESSIONAL ENGINEER
SOUTH CAROLINA
JAKE EAVENSON
10/19/2023
07/21/2026
Page 31 of 69
FRAMING NOTES:
1.ROOF SHEATHING: 15/32" APA-RATED 32/16 MIN. WOOD
STRUCTURAL PANELS MANUFACTURED W/ EXTERIOR-GRADE GLUE &
FASTENED W/ 8d COMMON NAILS (0.131"Øx2.5" LONG) OR
GALVANIZED 8d BOX NAILS (0.113"Øx2.5" LONG) AS FOLLOWS:
NAILING PATTERN:
SUPPORTED EDGES & DIAPHRAGM BOUNDARIES: 6" O.C.
FIELD & INTERMEDIATE SUPPORTS. 6" O.C.
2.ALL EXTERIOR WALLS ARE FRAMED W/ 2x6 @ 16" O.C. - U.N.O.
3.ALL NEW NON-LOAD BEARING WALLS ARE FRAMED W/ 2x4 @ 16"
O.C. - TOP OF WALLS TO BE FASTENED TO EXISTING STEEL JOISTS
PER 13/S400 & 14/S400. BOTTOM OF WALLS FASTENED PER ANCHOR
BOLT NOTES & 5/S300.
4.ALL EXTERIOR WALL SHEATHING AS FOLLOWS (U.N.O.):
15/32" APA-RATED SHEATHING, 32/16 MIN. WOOD STRUCTURAL
PANELS MANUFACTURED AS EXPOSURE 1 & FASTENED
W/ 8d COMMON NAILS (0.131"Øx2.5" LONG) OR GALVANIZED 8d BOX
NAILS (0.113"Øx2.5" LONG) AS FOLLOWS:
NAILING PATTERN:
SUPPORTED EDGES & DIAPHRAGM BOUNDARIES: 3" O.C.
FIELD & INTERMEDIATE SUPPORTS: 12" O.C.
ANCHOR BOLT NOTES:
1. PROVIDE 5/8"Ø x 10" LONG ANCHOR BOLTS W/ 2"x2"x14" THICK
WASHER SPACED AT 32" O.C. ALONG WALL SILL PLATE AT ALL
EXTERIOR WALLS & AS INDICATED - U.N.O.
PROVIDE (2) BOLTS (MIN.) PER PIECE & 12" MAX FROM EACH END OF
PIECE.
2. PROVIDE 1
4"x3" TAPCONS @ 24" O.C. (MIN.) AT ALL NEW INTERIOR
NON-LOAD BEARING WALLS.
PROVIDE (2) TAPCONS (MIN.) PER PIECE & 12" MAX FROM EACH END
OF PIECE.
- CONTROL JOINT (C.J.)
- TURNDOWN SLAB
- THICKENED SLAB
- NEW NON-LOAD BEARING WALL
- FOOTING MARK - SEE FOOTING SCHEDULE
- COLUMN MARK - SEE COLUMN SCHEDULE
GENERAL LEGEND
- CMU WALL - SEE MASONRY NOTES
F1
C1
- LOAD BEARING WALL
(2) 2x6 STUD PACK
HSS5x5x12
C1
C2
C3
2
N/A
COLUMN SCHEDULE
COLUMN TYPEMARK
# OF
KING STUDS
AT EACH END
FOR COLUMNS INSTALLED IN WALL FRAMING, THE COLUMN TYPE INDICATES
THE NUMBER AND TYPE OF "JACK STUDS" DIRECTLY SUPPORTING THE BEAM.
ADDITIONAL KING STUDS (IF APPLICABLE) ARE NOTED IN THE LAST COLUMN.
N/A W16x31
1
S203
CEILING FRAMING PLAN
SCALE: 1/8" - 1'-0"
CEILING FORMED BY
RAFTERS ABOVE
OPEN TO ABOVE
CEILING FORMED BY ACOUSTICAL
TILE CEILING - SEE ARCH.
CEILING FORMED BY
RAFTERS ABOVE
PRE-ENGINEERED CANOPY
ABOVE BY OTHERS
(3) 1.75"x9.25" 2.0E
LVL (DROPPED)(2) 2x10
(3) 1.75"x9.25" 2.0E LVL
C3
EXTEND STUD WALL PAST ROOF
FRAMING TO FORM PARAPET
WALL ABOVE - SEE 3/S400
C3
FACEMOUNT BEAM TO CORNER OF
EXISTING WALL W/ CONCEALED
FLANGE MASONRY HANGER OR EQUAL
C2
C3
C3
INFILL CMU WALL MATCHING DEPTH
OF EXISTING MASONRY WALL
C1
C1
EXISTING MASONRY
LINTEL TO REMAIN
(3) 1.75"x9.25" 2.0E
LVL (DROPPED)
C2
(3) 1.75"x9.25" 2.0E
LVL (DROPPED)
(3) 1.75"x9.25" 2.0E
LVL (DROPPED)
C2
(3) 1.75"x9.25" 2.0E
LVL (DROPPED)
(3) 1.75"x9.25" 2.0E
LVL (DROPPED)
4
S400
EXISTING STRUCTURE TO REMAIN
NEW INFILL NON-LOAD
BEARING WALL (TYP.)
COLUMN PER CANOPY
MANUFACTURER (TYP.)
5
S400
C1
(3) 2x10 (DROPPED
& CONT.)
10
S400
SEE 11/S400 FOR BEAM
CONNECTION @
CORNER STEEL COLUMN
WALL TO BE FRAMED
(2) 2x6 @ 16" O.C.
14
S400
TYP.
CONCEALED HANGER TO
STEEL COLUMN TO BEAM
- SIMILAR TO 11/S400
C1
2x8 @ 16" O.C.
NOTE: BEAMS NOTED AS
"LOW" SHALL BE LOCATED AT
THE TOP OF WINDOW ROUGH
OPENINGS W/ CLEARANCE AS
REQUIRED FOR INSTALLATION.
2
S203
PARTIAL HIGH CEILING FRAMING PLAN
SCALE: 1/8" - 1'-0"
C2C3
C3
C2
C2C3
C3
W14x26W14x26
W14x26 W14x26
W14x26W14x26
CEILING FORMED BY
BOTTOM CHORD OF
TRUSSES ABOVE
TYPICAL EXTERIOR
WALL FRAMING ABOVE
LOW BEAM ON 1/S203
1
S400
6
S400
CEILING
FRAMING PLANS
SHEET TITLE
PROJECT No.
DATE
REV.
No.DATENARRATIVE
0ISSUED FOR
PERMIT
MEMORY MATTERS
RENOVATION AND ADDITION
15 TRELLIS COURT
HILTON HEAD ISLAND,
SOUTH CAROLINA
26-562
06-05-2026
SHEET No.
STRUCTURAL DESIGN CONSULTANTS
S203
No. 7089
SOUTH
CAROLINA
SHEARLOCK
ENGINEERING,
LLC
CE
NOITA
RI TFICATE
ZIRO
OF
HT
AU
06-05-2026
1
UPDATED PER
EXISTING
CONDITIONS
07-21-2026
1
No. 33500
REGISTEREDPROFESSIONAL
ENGINEER
SOUTH CAROLINA
JAKE EAVENSON
10/19/2023
07/21/2026
Page 32 of 69
FRAMING NOTES:
1.ROOF SHEATHING: 15/32" APA-RATED 32/16 MIN. WOOD
STRUCTURAL PANELS MANUFACTURED W/ EXTERIOR-GRADE GLUE &
FASTENED W/ 8d COMMON NAILS (0.131"Øx2.5" LONG) OR
GALVANIZED 8d BOX NAILS (0.113"Øx2.5" LONG) AS FOLLOWS:
NAILING PATTERN:
SUPPORTED EDGES & DIAPHRAGM BOUNDARIES: 6" O.C.
FIELD & INTERMEDIATE SUPPORTS. 6" O.C.
2.ALL EXTERIOR WALLS ARE FRAMED W/ 2x6 @ 16" O.C. - U.N.O.
3.ALL NEW NON-LOAD BEARING WALLS ARE FRAMED W/ 2x4 @ 16"
O.C. - TOP OF WALLS TO BE FASTENED TO EXISTING STEEL JOISTS
PER 13/S400 & 14/S400. BOTTOM OF WALLS FASTENED PER ANCHOR
BOLT NOTES & 5/S300.
4.ALL EXTERIOR WALL SHEATHING AS FOLLOWS (U.N.O.):
15/32" APA-RATED SHEATHING, 32/16 MIN. WOOD STRUCTURAL
PANELS MANUFACTURED AS EXPOSURE 1 & FASTENED
W/ 8d COMMON NAILS (0.131"Øx2.5" LONG) OR GALVANIZED 8d BOX
NAILS (0.113"Øx2.5" LONG) AS FOLLOWS:
NAILING PATTERN:
SUPPORTED EDGES & DIAPHRAGM BOUNDARIES: 3" O.C.
FIELD & INTERMEDIATE SUPPORTS: 12" O.C.
- CONTROL JOINT (C.J.)
- TURNDOWN SLAB
- THICKENED SLAB
- NEW NON-LOAD BEARING WALL
- FOOTING MARK - SEE FOOTING SCHEDULE
- COLUMN MARK - SEE COLUMN SCHEDULE
GENERAL LEGEND
- CMU WALL - SEE MASONRY NOTES
F1
C1
- LOAD BEARING WALL
1
S204
ROOF FRAMING PLAN
SCALE: 1/8" - 1'-0"
PRE-ENGINEERED
TRUSSES @ 24" O.C.
PRE-ENGINEERED
TRUSSES @ 24" O.C.
PRE-ENGINEERED
TRUSSES @ 24" O.C.
HIP TRUSS
HIP TRUSS
HIP TRUSS
HIP TRUSS
6
S400
BEAM BELOW (TYP.)
SHED ROOF RAFTERS
TO BE 2x8 @ 16" O.C.
5
S400
SHED ROOF RAFTERS
TO BE 2x8 @ 16" O.C.
GIRDER TRUSS BY
MANUFACTURER
STUD WALL EXTENDS PAST
ROOF FRAMING TO FORM
PARAPET - SEE 3/S400
EXISTING STRUCTURE TO REMAIN
EXISTING PARAPET
WALL TO REMAIN (TYP.)
EXISTING HIGH ROOF
TO REMAIN (TYP.)
PRE-ENGINEERED
CANOPY BY OTHERS
SHED ROOF RAFTERS TO
BE 2x8 @ 16" O.C. (TYP.)4
S400
POST RAFTERS TO
WALL BELOW
1
S400
ROOF FRAMING
PLAN
SHEET TITLE
PROJECT No.
DATE
REV.
No.DATENARRATIVE
0ISSUED FOR
PERMIT
MEMORY MATTERS
RENOVATION AND ADDITION
15 TRELLIS COURT
HILTON HEAD ISLAND,
SOUTH CAROLINA
26-562
06-05-2026
SHEET No.
STRUCTURAL DESIGN CONSULTANTS
S204
No. 7089
SOUTH
CAROLINA
SHEARLOCK
ENGINEERING,
LLC
CE
NOITA
RI TFICATE
ZIRO
OF
HT
AU
06-05-2026
1
UPDATED PER
EXISTING
CONDITIONS
07-21-2026
No. 33500
REGISTERED PROFESSIONAL ENGINEER
SOUTH CAROLINA
JAKE EAVENSON
10/19/2023
07/21/2026
Page 33 of 69
SHEARWALL LEGEND
SW-1
- HOLD DOWN - SEE SCHEDULEHD-1
MF-1
- SHEARWALL - SEE SCHEDULE
- MOMENT FRAME - SEE SCHEDULE
FRAMING NOTES:
1.ROOF SHEATHING: 15/32" APA-RATED 32/16 MIN. WOOD
STRUCTURAL PANELS MANUFACTURED W/ EXTERIOR-GRADE GLUE &
FASTENED W/ 8d COMMON NAILS (0.131"Øx2.5" LONG) OR
GALVANIZED 8d BOX NAILS (0.113"Øx2.5" LONG) AS FOLLOWS:
NAILING PATTERN:
SUPPORTED EDGES & DIAPHRAGM BOUNDARIES: 6" O.C.
FIELD & INTERMEDIATE SUPPORTS. 6" O.C.
2.ALL EXTERIOR WALLS ARE FRAMED W/ 2x6 @ 16" O.C. - U.N.O.
3.ALL NEW NON-LOAD BEARING WALLS ARE FRAMED W/ 2x4 @ 16"
O.C. - TOP OF WALLS TO BE FASTENED TO EXISTING STEEL JOISTS
PER 13/S400 & 14/S400. BOTTOM OF WALLS FASTENED PER ANCHOR
BOLT NOTES & 5/S300.
4.ALL EXTERIOR WALL SHEATHING AS FOLLOWS (U.N.O.):
15/32" APA-RATED SHEATHING, 32/16 MIN. WOOD STRUCTURAL
PANELS MANUFACTURED AS EXPOSURE 1 & FASTENED
W/ 8d COMMON NAILS (0.131"Øx2.5" LONG) OR GALVANIZED 8d BOX
NAILS (0.113"Øx2.5" LONG) AS FOLLOWS:
NAILING PATTERN:
SUPPORTED EDGES & DIAPHRAGM BOUNDARIES: 3" O.C.
FIELD & INTERMEDIATE SUPPORTS: 12" O.C.
ANCHOR BOLT NOTES:
1. PROVIDE 5/8"Ø x 10" LONG ANCHOR BOLTS W/ 2"x2"x14" THICK
WASHER SPACED AT 32" O.C. ALONG WALL SILL PLATE AT ALL
EXTERIOR WALLS & AS INDICATED - U.N.O.
PROVIDE (2) BOLTS (MIN.) PER PIECE & 12" MAX FROM EACH END OF
PIECE.
2. PROVIDE 1
4"x3" TAPCONS @ 24" O.C. (MIN.) AT ALL NEW INTERIOR
NON-LOAD BEARING WALLS.
PROVIDE (2) TAPCONS (MIN.) PER PIECE & 12" MAX FROM EACH END
OF PIECE.
MOMENT FRAME SCHEDULE
MARK COLUMN BEAMCONNECTION
MF-1HSS5x5x12 &
W16x31W14x26CONN 1 - SEE DETAIL
9/S400
HOLD DOWN SCHEDULE
MARKTYPEALTERNATEINSTALLATION
HD-1SIMPSON HTT5
(OR EQUAL)
58"Ø THREADED RODPER MANUF. WITH (2) 2x6
COMPRESSION MEMBER FRAMING
HD-2STEEL COLUMN PER PLANN/AN/A
SHEARWALL SCHEDULE
SHEATHING
MARKSTRUCTURAL PANELFASTENER SIZESPACING AT
PANEL EDGES
SPACING AT
PANEL FIELD
SW-1
15/32" APA-RATED SHEATHING, 32/16
MIN. WOOD STRUCTURAL PANELS
MANUFACTURED AS EXPOSURE 1
8d COMMON NAILS (0.131"Øx2.5" LONG)
OR GALVANIZED 8d BOX NAILS
(0.113"Øx2.5" LONG)
3" O.C. 12" O.C.
1
S210
SHEAR WALL PLAN
SCALE: 1/8" - 1'-0"
EXISTING TO REMAIN
C3
C3
C2
C3
C3
C2
C2
MF-1
MF-1
MF-1
SW-1
HD-1
HD-2
SHEAR WALL PLAN
SHEET TITLE
PROJECT No.
DATE
REV.
No.DATENARRATIVE
0ISSUED FOR
PERMIT
MEMORY MATTERS
RENOVATION AND ADDITION
15 TRELLIS COURT
HILTON HEAD ISLAND,
SOUTH CAROLINA
26-562
06-05-2026
SHEET No.
STRUCTURAL DESIGN CONSULTANTS
S210
No. 7089
SOUTH
CAROLINA
SHEARLOCK
ENGINEERING,
LLC
CE
NOITA
RI TFICATE
ZIRO
OF
HT
AU
06-05-2026
1
UPDATED PER
EXISTING
CONDITIONS
07-21-2026
No. 33500
REGISTEREDPROFESSIONAL
ENGINEER
SOUTH CAROLINA
JAKE EAVENSON
10/19/2023
07/21/2026
Page 34 of 69
1
S300
FOUNDATION @ CMU STEM WALL
NOT TO SCALE
1'-0" (MIN.)
1'-4"
(2) #5 BARS (CONT.) 3"
CLR.
3"
CLR.
58"Ø HEADED ANCHOR
BOLTS @ 32" O.C.
P.T. 2x SILL PLATE
EXTERIOR SHEATHING
- SEE FRAMING NOTES
2x STUD WALL - SEE
FRAMING NOTES
FINISHED GRADE
WWF - SEE PLAN
CONCRETE SLAB - SEE PLAN
x
x x x x x x
x
#5 BARS @ 32" O.C.
#5 BAR (CONT.)
EXISTING STRUCTURE TO REMAIN
DOWEL #5 BARS @ 24" O.C. INTO EXISTING
FOUNDATION 6" (MIN.) W/ SIMPSON STRONG-TIE
SET-3G EPOXY PER MANUFACTURER'S SPECIFICATIONS
2
S300
FOUNDATION @ SPRINKLER ROOM
NOT TO SCALE
#5 DOWEL @ 24" O.C.
3" CLR.
4" SAND LAYER
10 MIL VAPOR BARRIER
24"
24"
xxxxxxxx
WWF - SEE PLAN
58"Ø HEADED ANCHOR BOLTS @ 32" O.C.
512"
MIN.
P.T. 2x SILL PLATE EXTERIOR SHEATHING -
SEE FRAMING NOTES
SEE FOOTING SCHEDULE FOR
SIZE AND REINFORCING
8" CMU WALL - SEE
MASONRY NOTES
FINISHED GRADE
1'-0" (MIN.)
3"
CLR.
3"
CLR.
6"
8" CMU BOND BEAM W/
(2) #5 BARS CONTINUOUS
2x STUD WALL - SEE
FRAMING NOTES
CONCRETE SLAB - SEE PLAN
4
S300
FOUNDATION AT STEEL COLUMN
NOT TO SCALE
4" SAND LAYER
10 MIL VAPOR BARRIER
xxxxxxxx
SEE FOOTING SCHEDULE FOR
SIZE AND REINFORCING
12" CMU WALL - SEE
MASONRY NOTES
FINISHED GRADE
1'-0" (MIN.)
3"
CLR.
3"
CLR.
6"
12" CMU BOND BEAM W/
(3) #5 BARS CONTINUOUS
STEEL COLUMN - SEE PLAN
CONCRETE SLAB - SEE PLAN
NOTE: PROVIDE #5 DOWEL @ 24" O.C. IN
SLAB HOOKED INTO CMU WALL PER 1/S300.
PROTECT COLUMN W/
MASTIC COATING
58" THICK BASE PLATE - SEE DETAIL
W16x31 PLATE DETAIL
58"x10"x1'-5" BASE PLATE
1'-5"
10"
(4) 58"Øx12" HEADED NELSON
STUDS PLUG WELDED TO THE
BOTTOM OF PLATE
3"11"3"
3"5"
2"
(4) 58"Øx12" HEADED NELSON STUDS PLUG
WELDED TO THE BOTTOM OF PLATE
STEEL COLUMN - SEE PLAN
TYP.3/16
HSS5x5 PLATE DETAIL
58"x11"x0'-11" BASE PLATE
11"
11"
(4) 58"Øx12" HEADED NELSON STUDS PLUG
WELDED TO THE BOTTOM OF PLATE
STEEL COLUMN - SEE PLAN
TYP.3/16
2"
6" 3"
3"6"
2"
WWF - SEE PLAN
512"
MIN.
1'-0"
EXISTING FOUNDATION TO REMAIN
FINISHED GRADE
3000psi CONCRETE RAMP
RAILING -
PER OWNER(SEE ARCH. PLAN FOR EXACT DIMENSION)
VARIES (3'-0" MAX.)
COMPACTED SUBGRADE -
SEE STRUCTURAL NOTES
SEE FOOTING SCHEDULE FOR
SIZE AND REINFORCING
40"
24"
3
S300
SECTION @ REAR RAMP
NOT TO SCALE
1'-0" (MIN.)
#5 BAR (CONT.) AT
TOP OF WALL (TYP.)
#5 HOOKED BAR
MATCHING CMU VERTICAL
REINFORCEMENT SPACING
#5 BAR MATCHING VERTICAL
REINFORCEMENT SPACING,
HOOKED INTO FOOTING
8" CMU WALL - SEE
MASONRY NOTES
EXISTING FOUNDATION
WALL TO REMAIN
EXISTING FOUNDATION
WALL TO REMAIN
6
S300
SLAB ON GRADE RAMP
NOT TO SCALE
8"
xxxxx
CONCRETE SLAB - SEE PLAN
WWF - SEE PLAN
3"
CLR.
3"
CLR.
#5 BAR (CONT.) (TYP.)
8"
FINISHED GRADE
x x x x x
10 MIL VAPOR BARRIER
4" SAND LAYER
COMPACTED SUBGRADE -
SEE STRUCTURAL NOTES8"
8"
SEE PLAN
1'-0"
NOTE: SEE FOOTING SCHEDULE ON FOUNDATION PLAN
FOR SIZE AND SPACING OF CONTINUOUS REINFORCING.
BAR SIZE LAP
24"
#5
#6 36"
30"
#4
2"x4 KEY JOINT
APPLY BONDING AGENT
TO FIRST POUR
3" CLR.
LAP
(TYP)
THICKNESS
VARIES
(SEE PLAN)
10
S300
CONSTRUCTION JOINT AT CONTINUOUS FOOTING
NOT TO SCALE
x x x x x x x x x x x x x
18" SAWCUT JOINT - FILL JOINT FULL DEPTH W/ SEMI-RIGID
EPOXY JOINT FILLER - WWF DISCONTINUOUS AT JOINT
COMPACTED SUBGRADE -
SEE STRUCTURAL NOTES
10 MIL VAPOR BARRIER
1"
112"
APPLY CURING COMPOUND
AFTER SLAB FINISHING
IS COMPLETE
4" SAND LAYER
CONCRETE SLAB - SEE PLAN
WWF - SEE PLAN
SAWCUT JOINT WITHIN 4 HOURS
AFTER POURING CONCRETE SLAB.
9
S300
SLAB CONTROL JOINT DETAIL - 4"
NOT TO SCALE
BAR SCHEDULE
BAR SIZE
24"
X
30"
36" #6
#5
1
1
X
VARIES
X
#4
X
X
CONTINUOUS
FOOTING
REINFORCING
DOWEL BAR TO MATCH
CONTINUOUS REINFORCEMENT
DOWEL BAR TO MATCH
CONTINUOUS REINFORCEMENT
1'-0"
2'-0" MAX.
X
MIN. LAP
(TYP.)
BAR SCHEDULE
BAR SIZE
#4
#5
#6 36"
30"
24"
X
NOTE: SEE FOOTING SCHEDULE ON FOUNDATION PLAN
FOR SIZE AND SPACING OF CONTINUOUS REINFORCING.
X
X
CORNER BARS TO MATCH
CONTINUOUS REINFORCING
(SEE SCHEDULE)
WIDTH VARIES
(SEE PLAN)
WIDTH VARIES
(SEE PLAN)
11
S300
CONTINUOUS REINFORCING AT CORNERS & INTERSECTIONS
NOT TO SCALE
8
S300
STEP FOOTING
NOT TO SCALE
5
S300
INTERIOR NON-LOAD BEARING WALL
NOT TO SCALE
EXISTING SLAB TO REMAIN
P.T. 2x SILL PLATE
INTERIOR NON-LOAD BEARING
WALL - SEE FRAMING NOTES
ATTACH SILL PLATE TO EXISTING
SLAB W/ 14"Øx3" TAPCON SCREWS
(OR EQUAL) @ 24" O.C.
NOTE: WHERE RAMP TRANSITIONS TO FLAT
SLAB ON GRADE, THICKEN SLAB TO 8" DEEP
AND 16" WIDE W/ (2) #5 BARS (CONT.).
7
S300
CMU PIER @ SERVICE YARD
NOT TO SCALE
1'-6"
x
x
x
xxxxxx
1'-0" (MIN.)
12" CMU PIER - SEE MASONRY NOTES
2
1
FINISHED GRADE
3" CLR.
3"
CLR.
CONCRETE SLAB - SEE PLAN
WWF - SEE PLAN
(2) #5 BARS (CONT.)
COMPACTED SUBGRADE -
SEE STRUCTURAL NOTES
10 MIL VAPOR BARRIER
4" SAND LAYER
(4) #5 BARS HOOKED
INTO FOUNDATION
1'-4"
#5 BARS @ 32" O.C.
NOTE: HEIGHT OF CMU PIER SHALL BE
7'-0" (MAX.) ABOVE SLAB ON GRADE.
SEE FOOTING SCHEDULE FOR
SIZE AND REINFORCING
3"
CLR.
3"
CLR.
12
S300
FOUNDATION @ PRE-ENGINEERED CANOPY COLUMN
NOT TO SCALE
4"
6" (MIN.)
FINISHED GRADE
PRE-ENGINEERED CANOPY COLUMN
AND ATTACHMENT BY FABRICATOR
NOTE: COLUMN FOUNDATION ATTACHMENT
TO BE DETAILED BY CANOPY MANUFACTURER
AND SUBMITTED TO E.O.R. FOR APPROVAL
PRIOR TO FABRICATION.
FOUNDATION
DETAILS
SHEET TITLE
PROJECT No.
DATE
REV.
No.DATENARRATIVE
0ISSUED FOR
PERMIT
MEMORY MATTERS
RENOVATION AND ADDITION
15 TRELLIS COURT
HILTON HEAD ISLAND,
SOUTH CAROLINA
26-562
06-05-2026
SHEET No.
STRUCTURAL DESIGN CONSULTANTS
S300
No. 7089
SOUTH
CAROLINA
SHEARLOCK
ENGINEERING,
LLC
CE
NOITA
RI TFICATE
ZIRO
OF
HT
AU
06-05-2026
1
UPDATED PER
EXISTING
CONDITIONS
07-21-2026
6"
No. 33500
REGISTERED PROFESSIONAL ENGINEER
SOUTH CAROLINA
JAKE EAVENSON
10/19/2023
07/21/2026
Page 35 of 69
RAFTER BEARING ELEV.
SEE ARCH. PLAN
ROOF SHEATHING - SEE FRAMING NOTES
RAFTER - SEE PLAN
12 SEE ARCH.
PLAN
ROOF FINISH - SEE ARCH. PLANS
PLATE
LINE
DOUBLE TOP PLATE
2x STUD WALL - SEE
FRAMING NOTES
EXTERIOR SHEATHING - SEE FRAMING NOTES
1
S400
EAVE DETAIL @ TRUSS
NOT TO SCALE
SIMPSON STRONG-TIE H2.5A HURRICANE CLIP
OR EQUAL, AT EACH RAFTER CONNECTION
2
S400
TYPICAL ROOF EAVE FRAMING
NOT TO SCALE
SIMPSON STRONG-TIE LUS24 OR EQUAL
2x4 LEDGER BOARD FASTENED TO WALL
W/ (2) 312" #12 WOOD SCREWS @ 16" O.C.
SIDELAP W/ (4) 10d NAILS
3
S400
PARAPET WALL DETAIL
NOT TO SCALE
SIMPSON STRONG-TIE LRU28Z
(OR EQUAL) AT EACH RAFTER
ROOF SHEATHING -
SEE FRAMING NOTES
RAFTER - SEE PLAN
2x STUD WALL - SEE
FRAMING NOTES
P.T. 2x LEDGER BOARD FASTENED TO EACH
STUD W/ (3) 312" #12 WOOD SCREWS (TYP.)
FLASHING AND ROOF FINISH -
SEE ARCH. PLAN
EXTERIOR SHEATHING -
SEE FRAMING NOTES
ROOF SHEATHING - SEE FRAMING NOTES
RAFTER - SEE PLAN
ROOF FINISH - SEE ARCH. PLANS
EAVE CONDITION
- SEE ARCH. PLAN
EXTERIOR SHEATHING -
SEE FRAMING NOTES
SEE 2/S400 FOR SOFFIT
FRAMING & CONNECTION
PLATE
LINE
4
S400
SECTION AT SPRINKLER ROOM
NOT TO SCALE
DOUBLE TOP PLATE
2x STUD WALL - SEE
FRAMING NOTES
EXISTING STRUCTURE TO REMAIN
GUTTER SYSTEM TO BE
REMOVED PER ARCH. PLANS
5
S400
SECTION THROUGH BREEZEWAY
NOT TO SCALE
EXISTING ROOF
STRUCTURE TO
REMAIN
EXISTING MASONRY
WALL TO REMAIN
6
S400
ROOF TRUSS AT STEEL
NOT TO SCALE
(2) SIMPSON STRONG-TIE H3
HURRICANE CLIP OR EQUAL AT EACH
TRUSS, ONE EACH SIDE OF TRUSS
BLOCKING BETWEEN EACH TRUSS
ROOF TRUSS PER MANUFACTURER
EAVE CONDITION - SEE
TRUSS MANUFACTURER
EXTERIOR SHEATHING -
SEE FRAMING NOTES
ROOF SHEATHING - SEE
FRAMING NOTES
SIMPSON STRONG-TIE
H2.5A HURRICANE CLIP OR
EQUAL AT EACH TRUSS
DOUBLE TOP PLATE
BLOCKING BETWEEN EACH TRUSS
ROOF TRUSS PER MANUFACTURER
2x STUD WALL - SEE
FRAMING NOTES
EAVE CONDITION - SEE
TRUSS MANUFACTURER
PLATE
LINE
EXTERIOR SHEATHING -
SEE FRAMING NOTES
ROOF SHEATHING - SEE
FRAMING NOTES
P.T. 2x PLATE FASTENED TO STEEL
W/ (2) SIMPSON STRONG-TIE
TFP1475 SCREWS @ 16" O.C.
2x STUD WALL - SEE
FRAMING NOTES
SINGLE TOP PLATE
STEEL BEAM - SEE PLAN
P.T. FULL-DEPTH BLOCKING FASTENED
W/ 12"Ø THROUGH BOLTS @ 24" O.C.,
STAGGERED HIGH AND LOW
EAVE CONDITION - SEE
ARCH. PLAN
2x FRAMING @ 16" O.C.
BLOCKING BETWEEN EACH RAFTER DOUBLE TOP PLATE
RAFTER - SEE PLAN
ROOF SHEATHING -
SEE FRAMING NOTES
BLOCKING BETWEEN RAFTERS
IN LAST (2) BAYS PER 3/S401
SIMPSON STRONG-TIE LRU28Z (OR EQUAL) AT EACH RAFTER
P.T. 2x LEDGER BOARD FASTENED TO EXISTING MASONRY
WALL W/ (2) 14" TITEN TURBO MASONRY ANCHORS @ 16" O.C.
SIMPSON STRONG-TIE H2.5A
HURRICANE CLIP OR EQUAL,
@ EACH RAFTER CONNECTION
BLOCKING BETWEEN EACH RAFTER
ROOF SHEATHING - SEE FRAMING NOTES
JOIST - SEE PLAN
ROOF FINISH - SEE ARCH. PLANS
EAVE CONDITION
- SEE ARCH. PLAN
EXTERIOR SHEATHING -
SEE FRAMING NOTES
SEE 2/S400 FOR SOFFIT
FRAMING & CONNECTION
PLATE
LINE
DOUBLE TOP PLATE
2x STUD WALL - SEE
FRAMING NOTES
GUTTER SYSTEM TO BE
REMOVED PER ARCH. PLANS
SIMPSON STRONG-TIE LRU28Z (OR EQUAL) AT EACH RAFTER
P.T. 2x LEDGER BOARD FASTENED TO EXISTING MASONRY
WALL W/ (2) 14" TITEN TURBO MASONRY ANCHORS @ 16" O.C.
SIMPSON STRONG-TIE H2.5A
HURRICANE CLIP OR EQUAL,
@ EACH RAFTER CONNECTION
BLOCKING BETWEEN
EACH RAFTER
RAFTER - SEE PLAN
7
S400
RETROFIT CMU LINTEL
NOT TO SCALE
ELEVATION VIEW
NOTE: SIMILAR CONNECTION AT BOTTOM OF POST.
(2) SIMPSON STRONG-TIE ST6224 OR
EQUAL - ONE EACH BEAM TO POST
COLUMN - SEE PLAN
BEAMS - SEE PLAN
8
S400
CONNECTION OF INTERIOR COLUMN TO BEAM
NOT TO SCALE
CLCOLUMN
38"x512"x1'-0" PLATE (TYP.)STEEL BEAM
- SEE PLAN 3"
112"
(4) 34"Ø A325N BOLTS IN 1316"Ø
HOLES AT 234" GAGE, TOP AND
BOTTOM (TYP.)
2"
CLCOLUMN
T.O.S. EL.
COORD. W/ ARCH.
12"x512"x2'-5" PLATE
STEEL BEAM
- SEE PLAN
112"
38"x4"x6" PLATE W/
(2) 34"Ø A325N BOLT
IN 1316"Ø HOLES (TYP.)3"
(4) 34"Ø A325N BOLTS IN 1316"Ø HOLES
AT 234" GAGE, TOP AND BOTTOM (TYP.)
TYP. 1/4
1/4
12"x512"x612" PLATE (TYP.)
2"
TYP.1/4
1/4
112"
9
S400
MOMENT FRAME CONNECTION
NOT TO SCALE
3"
112"
TYP.1/4
1/4 38"x512"x612" PLATE (TYP.)
TYP. 1/4
1/4 TYP.1/4
CLCOLUMN
38"x4"x6" PLATE W/
(2) 34"Ø A325N BOLT
IN 1316"Ø HOLES (TYP.)
TYP.1/4
1/4
112"
3"
112"
HSS COLUMN - SEE PLAN
HSS COLUMN - SEE PLAN
STEEL COLUMN - SEE PLAN
10
S400
LVL BEAM @ W COLUMN
NOT TO SCALE
STEEL COLUMN - SEE PLAN
LVL BEAM - SEE PLAN
FASTEN BEAM TO COLUMN W/ SIMPSON
STRONG-TIE HUC610 W/ (4) 1" WELD
SEGMENTS PER MANUFACTURER'S
SPECIFICATIONS
11
S400
LVL BEAM @ HSS COLUMN
NOT TO SCALE
LVL BEAM - SEE PLAN
FASTEN BEAM TO COLUMN W/
SIMPSON STRONG-TIE HUC610 W/
(8) #12 METAL SCREWS PER
MANUFACTURER'S SPECIFICATIONS
FASTEN JACK STUD TO STEEL W/
SIMPSON STRONG-TIE TFP1475
SCREWS @ 12" O.C. (VERTICAL)
STEEL COLUMN
- SEE PLAN
2x6 JACK STUD (TYP.)
SIMPSON STRONG-TIE
LUS26 @ EACH JOIST
STEEL COLUMN
- SEE PLAN FASTEN END STUD TO STEEL W/
SIMPSON STRONG-TIE TFP1475
SCREWS @ 12" O.C. (VERTICAL)
BOUNDARY NAIL EXTERIOR
SHEATHING TO END STUD
EXTERIOR SHEATHING
- SEE FRAMING NOTES
PLAN VIEW
12
S400
HSS COLUMN HOLD DOWN DETAIL
NOT TO SCALE
EXISTING STEEL
JOIST TO REMAIN
L2x2x18 (LLV) FASTENED THROUGH
BOTTOM CHORD OF EXISTING
STEEL JOIST W/ 38"Ø BOLT
2x CONT. PLATE FASTENED TO
BOTTOM OF ANGLE W/ (2) #12
SELF-TAPPING SCREWS
INTERIOR NON-LOAD BEARING
WALL - SEE FRAMING NOTES
13
S400
CONNECTION @ NON-LOAD BEARING WALL
NOT TO SCALE
2x CONT. PLATE FASTENED TO
BOTTOM OF ANGLE W/ (2) #12
SELF-TAPPING SCREWS
INTERIOR NON-LOAD BEARING
WALL - SEE FRAMING NOTES
SINGLE TOP PLATE FASTENED TO
CONTINUOUS PLATE ABOVE W/
SIMPSON STRONG-TIE SDPW14312
(OR EQUAL) PER MANUFACTURER'S
SPECIFICATIONS
SINGLE TOP PLATE FASTENED TO
CONTINUOUS PLATE ABOVE W/
SIMPSON STRONG-TIE SDPW14312
(OR EQUAL) PER MANUFACTURER'S
SPECIFICATIONS
14
S400
CONNECTION @ NON-LOAD BEARING WALL
NOT TO SCALE
EXISTING STEEL
JOIST TO REMAIN
2x STUD WALL - SEE
FRAMING NOTES
3 4"
3 4"
NOTE: BEAMS NOTED AS "LOW" PER PLAN SHALL BE
LOCATED AT THE TOP OF WINDOW ROUGH OPENINGS
W/ CLEARANCE AS REQUIRED FOR INSTALLATION.
NOTE: BEAMS NOTED AS "LOW" PER PLAN SHALL BE
LOCATED AT THE TOP OF WINDOW ROUGH OPENINGS
W/ CLEARANCE AS REQUIRED FOR INSTALLATION.
DETAIL
OMITTED
STRUCTURAL
DETAILS
SHEET TITLE
PROJECT No.
DATE
REV.
No.DATENARRATIVE
0ISSUED FOR
PERMIT
MEMORY MATTERS
RENOVATION AND ADDITION
15 TRELLIS COURT
HILTON HEAD ISLAND,
SOUTH CAROLINA
26-562
06-05-2026
SHEET No.
STRUCTURAL DESIGN CONSULTANTS
S400
No. 7089
SOUTH
CAROLINA
SHEARLOCK
ENGINEERING,
LLC
CE
NOITA
RI TFICATE
ZIRO
OF
HT
AU
06-05-2026
1
UPDATED PER
EXISTING
CONDITIONS
07-21-2026
11
No. 33500
REGISTERED PROFESSIONAL ENGINEER
SOUTH CAROLINA
JAKE EAVENSON
10/19/2023
07/21/2026
Page 36 of 69
BOUNDARY NAILING
ROOF FRAMING - SEE PLAN
FIELD NAILING AT
INTERMEDIATE
SUPPORTS
SUPPORTED PANEL
EDGE NAILING
DIRECTION OF FACE GRAIN SUPPORT ALL SHEATHING
EDGES IN ACCORDANCE W/
DIMENSIONAL LUMBER
FRAMING NOTES
EXTERIOR
ENDWALL
BLOCKING
FOR (2)
JOIST BAYS
BLOCKING
BETWEEN JOISTS
JOIST - SEE PLAN
FLOOR OR CEILING JOISTS
AA
PLAN
SECTION A-A
4
S401
CONNECTION OF ROOF SHEATHING
NOT TO SCALE
3
S401
BLOCKING AT ENDWALL
NOT TO SCALE
SIMPSON STRONG-TIE H2.5A
HURRICANE CLIP OR EQUAL, AT
EACH RAFTER CONNECTION
SIMPSON STRONG-TIE
CS22 COILED STRAP
W/ A MINIMUM OF
(10) 10d OR (12) 8d
NAILS IN BOTH
CONNECTED MEMBERS
COMPRESSION
MEMBERS
EACH SIDE OF ROD
2x BLOCKING @ 48" O.C.
MAX AND @ EVERY FREE
EDGE OF SHEATHING
2x STUDS
@ 16" O.C. MAX.
SIMPSON STRONG-TIE CNW
OR EQUAL COUPLER NUT
SIMPSON STRONG-TIE
H2.5A HURRICANE CLIP
OR EQUAL AT EACH
RAFTER CONNECTION
THREADED ROD - SEE HOLD
DOWN SCHEDULE
6"
(MIN.)
ANCHOR BOLT EMBEDDED INTO
FOUNDATION PER ASTM F1554
OR WITH SIMPSON SET EPOXY
ANCHOR (6" MIN. EMBED.)
GC TO COMPLY WITH MINIMUM
DIMENSIONS SHOWN FOR
WASHER AND NUT PLACEMENT
5"
(MIN.)
R.O.
HEADER CRIPPLE STUD
-SINGLE FOR R.O. < 4'
-DOUBLE FOR R.O. < 8'
(UNLESS NOTED
OTHERWISE ON
FRAMING PLANS)
CRIPPLE STUDS
TRUSS/ RAFTER BEARING
T.O.S.
RAFTER BEARING
FULL HEIGHT STUDS EACH
SIDE OF ROUGH OPENING -
12 OF STUDS INTERRUPTED
BY ROUGH OPENING (2 MIN.)
SILL ANCHOR BOLT -
SEE ANCHOR BOLT
NOTES
2
S401
UPLIFT STRAP CONNECTION
NOT TO SCALE
1
S401
DETAIL AT THREADED ROD
NOT TO SCALE
HOLD DOWN AT ENDS OF
SHEARWALLS - SEE PLAN
FOR TYPE AND LOCATION
2'-0" (MAX.)
BOUNDARY NAILING
AT ALL EDGES
HEADER - SEE
SCHEDULE
2x BLOCKING W/ 12"
C-D EXTERIOR GRADE
PLYWOOD SHEATHING
BETWEEN RAFTERS
SIMPSON STRONG-TIE
BEARING PLATE OR EQUAL
DOUBLE 2x TOP PL.
2x BLOCKING W/ 12" C-D
EXTERIOR PLYWOOD
SHEATHING BETWEEN
RAFTERS BOUNDARY NAILING
AT ALL EDGES
STUD SPACING SCHEDULE
EXTERIOR LOAD BEARING WALLS
2x4(2)2x42x6 2x8 STUD SIZE
UNBRACED
LENGTH
10'
12'
14'
16'
18'
20'
8' 16"O.C. 16"O.C. 16"O.C. 16"O.C.
12"O.C. 16"O.C. 16"O.C. 16"O.C.
16"O.C. 16"O.C.16"O.C.
12"O.C. 16"O.C. 16"O.C.
12"O.C. 16"O.C.
16"O.C.
12"O.C.-
- -
- -
-
-
-
-
-
6'-0" OR
HEADER SCHEDULE
R.O. WIDTH
4'-0" TO 6'-0"
GREATER
HEADER SIZE
(3) 2x10 (MIN.)
(2) 2x12 OR
AS SHOWN
LESS THAN 4'-0"(3) 2x8 (MIN.)
# OF JACK
STUDS
EACH END
# OF KING
STUDS
EACH END
22
23
12
STRUCTURAL
DETAILS
SHEET TITLE
PROJECT No.
DATE
REV.
No.DATENARRATIVE
0ISSUED FOR
PERMIT
MEMORY MATTERS
RENOVATION AND ADDITION
15 TRELLIS COURT
HILTON HEAD ISLAND,
SOUTH CAROLINA
26-562
06-05-2026
SHEET No.
STRUCTURAL DESIGN CONSULTANTS
S401
No. 7089
SOUTH
CAROLINA
SHEARLOCK
ENGINEERING,
LLC
CE
NOITA
RI TFICATE
ZIRO
OF
HT
AU
06-05-2026
1
UPDATED PER
EXISTING
CONDITIONS
07-21-2026
No. 33500
REGISTERED PROFESSIONAL ENGINEER
SOUTH CAROLINA
JAKE EAVENSON
10/19/2023
07/21/2026
Page 37 of 69
NAILING PROVIDED IN
HORIZONTAL FRAMING
MEMBER (SINGLE OR
DOUBLE ROW)
FOUNDATION -
SEE PLAN
PANEL ATTACHMENT TO
BOTTOM PLATE - SEE
DETAIL 5/S402
P.T. BOTTOM PLATE
NAILING PROVIDED IN
STUDS ON EACH SIDE
OF HORIZONTAL JOINT
BAND JOIST
PANEL ATTACHMENT TO
UPPER TOP PLATE - SEE
DETAIL 5/S402
DOUBLE TOP PLATE
BAND JOIST
6
S402
FOUNDATION -
SEE PLAN
PANEL ATTACHMENT TO
BOTTOM PLATE - SEE
DETAIL 5/S402
P.T. BOTTOM PLATE
PANEL ATTACHMENT TO
UPPER TOP PLATE - SEE
DETAIL 5/S402
DOUBLE TOP PLATE
1
S402
HORIZONTAL FRAMING MEMBER
NOT TO SCALE
PANEL SPLICE OCCURRING OVER
4
S402
2
S402
PANEL SPLICE OCCURRING ACROSS STUDS
NOT TO SCALE
SHEAR WALL DESIGN NAIL SPACING
NAIL SPACING AT
INTERMEDIATE
FRAMING, 12" O.C.
UPLIFT NAIL SPACING PER PLAN
3
S402
PANEL ATTACHMENT
NOT TO SCALE
8'-0"
4'-0"
3 4"
12"
514"6"
SPACING
(FOR SHEAR
WALL DESIGN)
INCREASE STUD NAILING
FOR UPLIFT (EACH SIDE OF
HORIZONTAL JOINT)
INCREASE STUD NAILING
FOR UPLIFT (EACH SIDE
OF HORIZONTAL JOINT)
3 4"
PANEL EDGE
BLOCKING, SAME SPECIES
AS TOP AND BOTTOM PLATES
(2x FLAT-WISE SHOWN)
4
S402
DETAIL
NOT TO SCALE
618"
12"
3 4"
SPACING
PANEL EDGE
SPACING
PANEL EDGE
SPACING
SINGLE ROW OF FASTENERS
DOUBLE ROW OF FASTENERS
SPACING
3 4"
PANEL EDGE
SHEATHING EDGE AT BOTTOM PLATE
(SINGLE ROW AND DOUBLE ROW OF
FASTENERS)
12"
12" SPACING
SHEATHING EDGE AT TOP PLATE
(SINGLE ROW AND DOUBLE ROW OF
FASTENERS)
SINGLE ROW OF FASTENERS
DOUBLE ROW OF FASTENERS
SPACINGPANEL EDGE
SPACING
PANEL EDGE
3 4"
SINGLE ROW OF FASTENERS DOUBLE ROW OF FASTENERS
12"
12"SPACING
PANEL EDGE
3 4"SPACING
12"
5
S402
DETAIL
NOT TO SCALE
SPACING
(SINGLE ROW
SHOWN)
3 4"PANEL EDGE
SHEATHING
SPLICE PLATE
A
A
2x FLAT-WISE
BLOCKING
SHEATHING SPLICE PLATE,
SAME THICKNESS AND
FACE GRAIN ORIENTATION
AS SHEATHING
SECTION A-A
7
S402
SHEATHING SPLICE PLATE (ALTERNATE DETAIL)
NOT TO SCALE
6
S402
DETAIL
NOT TO SCALE
312"
112"
STRUCTURAL
DETAILS
SHEET TITLE
PROJECT No.
DATE
REV.
No.DATENARRATIVE
0ISSUED FOR
PERMIT
MEMORY MATTERS
RENOVATION AND ADDITION
15 TRELLIS COURT
HILTON HEAD ISLAND,
SOUTH CAROLINA
26-562
06-05-2026
SHEET No.
STRUCTURAL DESIGN CONSULTANTS
S402
No. 7089
SOUTH
CAROLINA
SHEARLOCK
ENGINEERING,
LLC
CE
NOITA
RI TFICATE
ZIRO
OF
HT
AU
06-05-2026
1
UPDATED PER
EXISTING
CONDITIONS
07-21-2026
No. 33500
REGISTERED PROFESSIONAL ENGINEER
SOUTH CAROLINA
JAKE EAVENSON
10/19/2023
07/21/2026
Page 38 of 69
©
LONDONO
Page 39 of 69
©
LONDONO
Page 40 of 69
©
LONDONO
Page 41 of 69
©
LONDONO
Page 42 of 69
©
LONDONO
Page 43 of 69
©
LONDONO
Page 44 of 69
©
LONDONO
Page 45 of 69
©
LONDONO
Page 46 of 69
©
LONDONO
Page 47 of 69
©
LONDONO
Page 48 of 69
©
LONDONO
Page 49 of 69
MEMORY MATTERS RENOV AION
15 TRELLIS COURT
SITE PLANS
Page 50 of 69
COVER SHEET ANDPROJECT NOTES
SHEET INDEX
ALL ARCHITECTURALINFORMATION WAS TAKEN FROMDIGITAL FILES PROVIDED BY:PDG ARCHITECTSHILTON HEAD ISLAND, SC.(843) 785.5171
3 DAYS BEFORE DIGGINGCALL TOLL FREE1-888-721-7877A ONE-CALL SYSTEM FOR COMMUNITY AND JOB SAFETYUTILITY PROTECTION CENTER****CAUTION****CS
PROJECT TEAMARCHITECTUREWITMER JONES KEEFERBLUFFTON, SC(843) 757.7411LANDSCAPE ARCHITECTISSUED:JULY 29, 2026
SITE DEVELOPMENT PLANSFORMEMORY MATTERSHILTON HEAD ISLAND, SOUTH CAROLINA
DRAWING NUMBERDRAWING TITLE
DESIGN CONCEPTS, DRAWING, SHEETS,LOGOS, SPECIFICATIONS, DETAILS,WRITTEN MATERIAL SHALL NOT BE USEDOR REPRODUCED IN WHOLE OR IN PARTIN ANY FORM WITHOUT PRIOR WRITTENCONSENT OF WJK LTD.© 2026 WJK LTD.THIS SHEET TO SCALE AT: 24"X36"
DATE:PROJECT NO.:DRAWN BY:CHECKED BY:JUL 29, 202626056.01SDJC
REVISIONS:DRB SUBMITTALPLAN, NOT FORCONSTRUCTION
CS-L10-L11-L50-L200-L300-L400 -L500-L501-L600-L601 -L602 -COVER SHEETEXISTING CONDITIONSEXISTING CONDITIONS - PHOTOSDEMOLITION PLANLAYOUT PLANGRADING PLANUTILITY PLANPLANTING PLANPLANT SCHEDULE AND DETAILSSITE DETAILS - 01SITE DETAILS - 02SITE DETAILS - 03
1.ALL NOTES APPLY TO ALL DRAWINGS AND ALL TRADES.2.REFER TO ENGINEERING PLANS FOR LAYOUT AND LOCATION OF UTILITIES AND ROADS.3.ALL SURVEY AND SITE INFORMATION WERE COMPILED FROM A VARIETY OF SOURCES AT VARIOUS TIMES.SITE INFORMATION MUST BE FIELD VERIFIED BEFORE CONSTRUCTION BEGINS. REPORT ANY DISCREPANCIES TO THE OWNER OR OWNER'S REPRESENTATIVE.4.IT IS THE RESPONSIBILITY OF ALL CONTRACTORS AND TRADES TO COORDINATE THE INSTALLATION OF THEIR WORK WITH THE INSTALLATION OF WORK BY ALL OTHER CONTRACTORS AND TRADES.5.THE REQUIREMENTS OF THE SPECIFICATIONS, DRAWINGS, GENERAL REQUIREMENTS, AND ALL ITEMS OF THE CONTRACT DOCUMENTS ARE EQUALLY BINDING FOR ALL CONTRACTORS AND TRADES.6.EACH CONTRACTOR IS REQUIRED TO MAINTAIN FULL (COLOR) SETS OF THE CONTRACT DOCUMENTSFOR HIS EMPLOYEES USE ON THE PROJECT TO ASSURE THAT ALL WORK IS PROPERLY COORDINATEDAND FOR REVIEWS BY COUNTY AND / OR MUNICIPALITY OFFICIALS FOR INSPECTIONS.7.ALL CONTRACTORS AND ALL TRADES ARE RESPONSIBLE FOR OBTAINING THE CORRECT PERMITS AND INSPECTIONS PRIOR TO CONSTRUCTION AS REQUIRED BY LOCAL PLANNING, ZONING, BUILDING CODEAND OTHER TOWN AUTHORITIES.8.W.J.K. LTD., THE OWNER AND / OR THE OWNER'S REPRESENTATIVE SHALL BE NOTIFIED OF ANY SITE CONDITIONS WHICH MAY NECESSITATE MODIFICATION TO THE PLAN. THE OWNER OR OWNER'SREPRESENTATIVE SHALL MAKE 'INFIELD MODIFICATIONS,' IF NECESSARY.9.CONTRACTOR SHALL PROVIDE AND FURNISH ALL MATERIALS, EQUIPMENT AND LABOR NECESSARY FOR ALL CONSTRUCTION, PROTECTION, MAINTENANCE AND RELATED ITEMS TO COMPLETE WORKINDICATED ON THE DRAWINGS.10.BEFORE COMMENCING ANY WORK CONTRACTOR SHALL ASCERTAIN THE LOCATION OF ALL UTILITIES,SUB-SURFACE DRAINAGE, AND UNDERGROUND CONSTRUCTION SO THAT PROPER PRECAUTIONS MAY BE TAKEN NOT TO DISTURB ANY SUB-SURFACE IMPROVEMENTS. CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS IN BRINGING EQUIPMENT ON TO AND OFF OF THE SITE, PROTECTING WALKS,PAVING, STEPS AND OTHER EXISTING CONSTRICTION ON THE SITE. CONTACTS SHALL BE MADE BY CONTRACTOR WITH PROPER AUTHORITIES BEFORE AND DURING THIS WORK SO AS TO COMPLY WITH ALL REGULATIONS AND ORDINANCES.11.CONTRACTOR SHALL FIELD LOCATE ALL UTILITIES AND CONFIRM / DETERMINE UTILITY ELEVATIONSPRIOR TO CONSTRUCTION. CONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE AND MAKE REPAIRS, AT THEIR OWN EXPENSE, THAT MAY OCCUR TO EXISTING UTILITIES IN ACCORDANCE WITH NATIONAL,STATE AND LOCAL CODES.12.CONTRACTOR SHALL VERIFY ALL EXISTING TREE CONDITIONS AND ELEVATIONS PRIOR TO CONSTRUCTION. CONTRACTOR SHALL NOTIFY THE OWNER OR OWNER'S REPRESENTATIVE OF ANY DISCREPANCIES PRIOR TO THEIR REMOVAL.13.CONTRACTOR SHALL PROTECT AND INSTALL TREE PROTECTION FENCE AROUND THE DRIP LINE OF ALL TREES, NATURAL AREAS AND EXISTING VEGETATION TO REMAIN. TREE PROTECTION LOCATION SHALLBE APPROVED BY LANDSCAPE ARCHITECT PRIOR TO CONSTRUCTION.14.ALL CONSTRUCTION FOR ALL TRADES SHALL CONFORM TO OR EXCEED THE PRODUCTMANUFACTURER'S RECOMMENDATIONS, REGULATIONS OF THE TOWN OF HILTON HEAD AND THE AMERICANS WITH DISABILITIES ACT, AND / OR OTHER APPLICABLE NATIONAL, STATE, AND LOCALCODES AND ANY OTHER GOVERNING AUTHORITIES.15.CONTRACTOR ACCESS FOR CONSTRUCTION AS DIRECTED BY THE OWNER OR OWNER'S REPRESENTATIVE.16.CONTRACTOR SHALL PROTECT THE GENERAL PUBLIC FROM CONSTRUCTION AREAS DURINGCONSTRUCTION.17.THE OWNER MAY REQUIRE FLAG MEN TO BE AVAILABLE DURING THE CONSTRUCTION PROCESS.18.ANY DEVIATIONS FROM THESE PLANS MUST BE SPECIFICALLY APPROVED BY W.J.K. LTD., AND THE OWNER OR OWNER'S REPRESENTATIVE.
GENERAL NOTES:
1.THE CONTRACTOR, BEFORE BEGINNING ANY DEMOLITION ACTIVITY, SHALL CONTACT THE LOCALUTILITIES FOR INSTRUCTION ON SPECIAL PROCEDURES THAT MAY BE REQUIRED BY THE UTILITIESCONCERNING DEMOLITION.2.ALL DEMOLISHED MATERIAL SHALL BE HAULED AWAY AND DISPOSED OF PROPERLY IN A LANDFILL AS APPLICABLE PER TOWN OF HILTON HEAD CODE(S).3.THE CONTRACTOR SHALL FOLLOW ALL REQUIREMENTS OF LOCAL, STATE AND FEDERAL REGULATORYAGENCIES WHICH MAY HAVE JURISDICTION OVER SUCH ACTIVITIES.4.THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL DATA PROVIDED IN THESE DRAWINGS. THE CONTRACTOR SHALL PERFORM HIS OWN ESTIMATE OF MATERIAL FOR DEMOLITION AND REPORT ANY DISCREPANCIES TO THE OWNER OR THE OWNER'S REPRESENTATIVE PRIOR TO BEGINNING WORK.5.ALL UTILITIES SHOWN ON THE DRAWINGS ARE APPROXIMATE AND FOR ESTIMATING PURPOSES ONLY.THE EXACT LOCATIONS SHALL BE FIELD VERIFIED BY THE CONTRACTOR PRIOR TO BEGINNINGDEMOLITION WORK. ALL UTILITIES SHALL BE LOCATED AND PROTECTED TO PREVENT DAMAGE. ANY DAMAGE WHICH MAY OCCUR DURING THE CONSTRUCTION PROCESS IS TO BE PROMPTLY REPORTED TO THE APPROPRIATE UTILITY AUTHORITY AND REPAIRS SHALL BE MADE IN ACCORDANCE WITH THEIRREQUIREMENTS. THE SAFE DEMOLITION AND REMOVAL OF UTILITIES, STRUCTURES AND EQUIPMENT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR.6.IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO NOTIFY, AT THE DIRECTION OF THE OWNER OR OWNER'S REPRESENTATIVE, THE UTILITIES HAVING JURISDICTION OVER ANY UTILITY EASEMENTS OF ANY KIND FOR APPROVAL OF WORK WITHIN THE EASEMENT.7.REMOVAL OF ANY AND ALL MATERIALS INDICATED INCLUDES ALL MATERIALS ASSOCIATED WITH THAT ITEM INCLUDING SUBSURFACE MATERIAL, IF APPLICABLE, NOT NEEDED OR IN NEED OF REPAIR OR REPLACEMENT.8.THE CONTRACTOR SHALL TAKE CARE WHEN WORKING AROUND EXISTING TREES SCHEDULED TO REMAIN. PROPER TREE PROTECTION IN ACCORDANCE WITH LOCAL CODES SHALL BE MADE PRIOR TO CONSTRUCTION BEGINNING AND THROUGHOUT THE CONSTRUCTION PROCESS.9.SOME TREES AND SHRUBS SCHEDULED FOR RELOCATION AND REUSE ON THE PROPERTY MAY NOT BE SALVAGEABLE DUE TO UNDERGROUND UTILITIES.10.BARRIERS AND / OR FLAG MEN MAY BE REQUIRED FOR SAFETY, VERIFY REQUIREMENTS WITH THE OWNER FOR SUCH NEEDS PRIOR TO BEGINNING THE WORK.11.THE OWNER SHALL BE NOTIFIED AS TO THE TIMING OF THE WORK SO THAT PROPER SECURITYNOTIFICATION IS MADE.
DEMOLITION NOTES:
1.ALL CONSTRUCTION STAKING SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR.2.CONTRACTOR TO USE DIGITAL FILES PROVIDED BY WITMER-JONES-KEEFER, LTD. TO LAYOUT AND STAKEALL SITE IMPROVEMENTS AND ELEMENTS. FINAL LAYOUT AND STAKING TO BE FIELD VERIFIED AND APPROVED BY LANDSCAPE ARCHITECT AND OWNER OR OWNER'S REPRESENTATIVE PRIOR TO CONSTRUCTION.3.CONTRACTOR SHALL FIELD LOCATE, STAKE AND USE COLOR CODED SPRAY PAINT FOR ALL ABOVE AND BELOW GROUND UTILITIES. CONTRACTOR TO CONFIRM / DETERMINE UTILITY ELEVATIONS PRIOR TO CONSTRUCTION. ANY EXISTING UTILITY CONFLICTS WITH SITE IMPROVEMENTS TO BE REPORTED TO OWNER, OWNER'S REPRESENTATIVE AND LANDSCAPE ARCHITECT PRIOR TO CONSTRUCTION.CONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE TO EXISTING UTILITIES AS STATED IN THE GENERALNOTES.4.ALL SITE IMPROVEMENTS REPRESENTED IN THIS SET OF PLANS SHALL BE STAKED AND REVIEWED WITH THE OWNER OR OWNER'S REPRESENTATIVE PRIOR TO CONSTRUCTION. ANY DISCREPANCIES TO BE REPORTED TO THE OWNER, OWNER'S REPRESENTATIVE OR LANDSCAPE ARCHITECT.5.ALL DIMENSIONS ARE TO EDGE OF PAVING AND CENTERLINE OF WALLS AND COLUMNS UNLESSOTHERWISE INDICATED.6.ALL ANGLES ARE 90 UNLESS OTHERWISE INDICATED.7.CONTRACTOR SHALL PROVIDE LIGHTING, IRRIGATION AND ANY OTHER CONDUIT NEEDED TO ALL LANDSCAPE AREAS.8.ANY AND ALL FIELD ADJUSTMENTS SHALL RECEIVE APPROVAL FROM THE OWNER, OWNER'SREPRESENTATIVE OR LANDSCAPE ARCHITECT PRIOR TO CONSTRUCTION.
LAYOUT NOTES:
GRADING NOTES:
1.THE INTENT OF THE LIGHTING DESIGN IS TO PROVIDE LOW LEVEL UNOBTRUSIVE SITE LIGHTING OR ARCHITECTURAL ELEMENTS. THE CONTRACTOR SHALL MAKE EVERY EFFORT TO CREATE THIS EFFECT BY CLOSE COORDINATION WITH THE LANDSCAPE ARCHITECT AND CAREFUL PLACEMENT OF ALL FIXTURES.2.THE CONTRACTOR SHALL ENGINEER THE ELECTRICAL SYSTEM BASED ON THE LOCATION AND TYPE OF FIXTURES AS SHOWN ON THE PLAN. PROPERLY SIZED WIRING, TRANSFORMERS, BREAKERS, ACCESSORIES,ETC., SHALL BE PROVIDED BY THE CONTRACTOR AS NECESSARY TO GUARANTEE A COMPLETELYFUNCTIONAL LIGHTING, DISTRIBUTION AND CONTROL SYSTEM.3.CONTRACTOR TO PROVIDE ELECTRICAL PLANS AND SHOP DRAWINGS FOR REVIEW AND APPROVAL BY THE LANDSCAPE ARCHITECT AND OWNER OR OWNER'S REPRESENTATIVE PRIOR TO INSTALLATION.4.ALL LIGHTING EQUIPMENT SHALL BE INSTALLED PER MANUFACTURERS INSTRUCTIONS AND RECOMMENDATIONS, AND MUST COMPLY WITH ALL APPLICABLE STATE AND COUNTY CODES.5.THE CONTRACTOR IS RESPONSIBLE FOR ACQUIRING ALL NECESSARY PERMITS AND INSPECTION / APPROVALS REQUIRED.6.THE CONTRACTOR SHALL STAKE OUT ALL LIGHT FIXTURE AND TRANSFORMER LOCATIONS FOR APPROVAL BY THE LANDSCAPE ARCHITECT, OWNER, OR OWNER'S REPRESENTATIVE PRIOR TO INSTALLATION. EXACT LOCATIONS OF CONTROLLERS, ELECTRICAL PANELS, ETC. TO BE COORDINATEDWITH AND APPROVED BY OWNER, OWNER'S REPRESENTATIVE OR LANDSCAPE ARCHITECT.7.FINAL AIMING AND ADJUSTMENT SHALL BE MADE AT NIGHT WITH LANDSCAPE ARCHITECT PRESENT TO GIVE FINAL APPROVAL.8.THE CONTRACTOR SHALL COORDINATE, STAKE AND FLAG ALL LOCATIONS WHERE ELECTRICALCONDUIT OR P.V.C. SLEEVING MAY BE REQUIRED BENEATH WALKS OR OTHER PAVED AREAS PRIOR TO HARDSCAPE INSTALLATION.9.ALL ELECTRICAL WIRING RUNNING UNDER PAVED AREAS SHALL BE PLACED IN ELECTRICAL CONDUIT OR PVC SLEEVES PROVIDED BY CONTRACTOR.10.CONTRACTOR SHALL RUN ALL NECESSARY ELECTRICAL WIRING TO UTILITY PANEL AND TRANSFORMER.11.CONTRACTOR SHALL PROVIDE A MINIMUM OF 36" OF BURIES EXCESS CABLE AT EACH FIXTURE TO ALLOW FOR FIXTURE ADJUSTMENT.12.ALL LIGHTING TO BE PLACED ON AN APPROPRIATE TIMER. THE CONTRACTOR SHALL SELECT AN APPROPRIATE TIMER FOR ALL LIGHTS AND SET THE TIME APPROPRIATELY FOR PROPER NIGHT TIME ILLUMINATION, FOR APPROVAL BY OWNER OR OWNER'S REPRESENTATIVE.13.CONTRACTOR SHALL PROVIDE GROUND FAULT CIRCUIT BREAKERS FOR ALL CIRCUITS AS REQUIRED BY NATIONAL, STATE AND LOCAL CODES.14.THE CONTRACTOR SHALL PROVIDE ALL EQUIPMENT, LABOR, EXCAVATION AND BACKFILL NECESSARY TO COMPLETE THE WORK.15.ALL FIXTURES PER MODELS SPECIFIED UNLESS CONTRACTOR GETS APPROVAL FROM LANDSCAPEARCHITECT FOR A SUBSTITUTION.16.SYSTEM INSTALLATION, INCLUDING PARTS AND LABOR, SHALL BE GUARANTEED AND REPAIRED AS NECESSARY BY THE CONTRACTOR FOR ONE YEAR.17.CONTRACTOR TO PROVIDE "AS-BUILT" DRAWINGS IMMEDIATELY AFTER FINAL ACCEPTANCE, ALONGWITH ALL INSTRUCTION MANUALS FOR ALL EQUIPMENT INSTALLED.18.IF POSSIBLE, FIELD MODIFICATIONS WILL BE DIRECTED BY THE LANDSCAPE ARCHITECT, OWNER OR OWNER'S REPRESENTATIVE.
LIGHTING NOTES:
1.ALL CONTRACTORS AND ALL TRADES ARE RESPONSIBLE FOR OBTAINING THE CORRECT PERMITS AND INSPECTIONS PRIOR TO CONSTRUCTION AS REQUIRED BY LOCAL PLANNING, ZONING, BUILDING CODEAND OTHER TOWN AUTHORITIES.2.CONTRACTOR SHALL PROVIDE SAMPLES OF ALL MATERIALS AND OBTAIN APPROVAL FROM OWNER,OWNER'S REPRESENTATIVE OR LANDSCAPE ARCHITECT PRIOR TO CONSTRUCTION.3.ON SITE TOPOGRAPHY MAY REQUIRE ADJUSTMENTS OF FINAL SPOT ELEVATIONS ON SITE FOR PROPOSED VERTICAL CONSTRUCTION ELEMENTS. THE CONTRACTOR SHALL NOTIFY THE OWNER OR OWNER'S REPRESENTATIVE PROMPTLY UPON THE DISCOVERY OF ANY SUCH REQUIRED ADJUSTMENTS.4.THE CONTRACTOR SHALL PROVIDE FILL AS IS REQUIRED TO OBTAIN PROPER RELATIONSHIP OF FOOTINGTO FINISH GRADE REQUIREMENTS - FEATHER FILL TO ADJACENT EXISTING GRADE TO ASSURE A COORDINATED AND DESIRED EFFECT.5.THE CONTRACTOR IS RESPONSIBLE FOR ALL DAMAGE TO EXISTING CONDITIONS SCHEDULED TO REMAINDURING CONSTRUCTION.6.THE CONTRACTOR IS RESPONSIBLE FOR LOCATING ALL EXISTING UTILITIES AND FOR ANY DAMAGE THAT MAY OCCUR TO EXISTING UTILITIES DURING CONSTRUCTION.7.'IN-FIELD MODIFICATIONS' MAY BE NECESSARY TO PRODUCE DESIRED EFFECT. MODIFICATIONS TO BE APPROVED BY LANDSCAPE ARCHITECT AND OWNER OR OWNER'S REPRESENTATIVE.8.ALL WELDS TO BE CONTINUOUS.9.FOR ALL WOOD MEMBERS, ALL CUTS SHALL BE EVEN AND JOINTS FLUSH. SAND FOUR SIDES AND FILL IMPERFECTIONS, COUNTERSINKS AND NAIL HOLES TO ASSURE EVEN FINISH.10.CONTRACTOR SHALL VERIFY ALL WOOD MEMBERS FOR APPROPRIATE SIZE, SPACING, ATTACHMENTSAND STRUCTURAL STABILITY PRIOR TO CONSTRUCTION. CONTRACTOR TO REPORT ANY DISCREPANCIESTO OWNER, OWNER'S REPRESENTATIVE OR LANDSCAPE ARCHITECT.11.ALL NOTCHES SHALL BE SHOP CUT TO ASSURE TIGHT JOINTS. EACH MEMBER SHALL BE DRIVEN HOMETO ASSURE TIGHT FIT. PILOT HOLES SHALL BE DRILLED FOR EACH CARRIAGE BOLT. PLUG, SEAL AND PRIME.12.FINISH ALL SIDES AND CAULK ALL JOINTS WITH APPROPRIATE EXTERIOR CAULK PRIOR TO FINISHING.13.ALL CONNECTORS, UNLESS OTHERWISE SPECIFIED, SHALL BE STAINLESS STEEL. BOLTS, THREADED RODS,WASHERS, NUTS AND ALL BUILDING HARDWARE SHALL BE STAINLESS STEEL AND SUITABLE FOR PRESSURE TREATED WOOD. ALL THROUGH BOLTS TO BE SMOOTH SHAFT WITH STAINLESS STEEL NUTS,BOLTS AND WASHERS. ALL NAILS AND FINISH NAILS SHALL BE ANNULAR STAINLESS STEEL.14.ALL DECKING SHALL BE SECURED WITH STAINLESS STEEL SCREWS SIZED FOR DECK APPLICATION.MINIMUM 3" APART.
CONSTRUCTION NOTES:
PLANTING NOTES:1.CONTRACTOR IS RESPONSIBLE FOR INSPECTION OF EXISTING CONDITIONS, INCLUDING UTILITIES, AND PROMPTLY REPORTING ANY DISCREPANCIES OR CONFLICTS WITH PLANTING AREAS. REPORTINFORMATION TO OWNER, OWNER'S REPRESENTATIVE AND LANDSCAPE ARCHITECT.2.CONTRACTOR SHALL FIELD LOCATE ALL UTILITIES. CONTRACTOR IS RESPONSIBLE FOR ANY DAMAGEAND MAKE REPAIRS THAT MAY OCCUR TO EXISTING UTILITIES IN ACCORDANCE WITH NATIONAL, STATEAND LOCAL CODES.3.LANDSCAPE PLANTING AND / OR MULCHED AREAS TO BE FINE GRADED, HAND RAKED SMOOTH AND FREE OF DEBRIS.4.CONTRACTOR TO PERFORM SOIL TESTS AS NECESSARY TO ASSURE PLANT HEALTH AND GROWTH.5.MULCH ALL PLANTING BEDS TO A MIN. 3" DEPTH WITH MULCH SPECIFIED IN PLANT SCHEDULE.6.CONTRACTOR VERIFIES THAT ALL PLANT MATERIAL IS DETERMINED AVAILABLE AS SPECIFIED WHEN BID / PROPOSAL IS SUBMITTED.7.PLANT SCHEDULE WAS PREPARED FOR ESTIMATING PURPOSES ONLY. CONTRACTOR SHALL MAKE OWN QUANTITY TAKEOFFS USING DRAWINGS TO DETERMINE QUANTITIES TO HIS SATISFACTION, REPORTINGPROMPTLY ANY DISCREPANCIES WHICH MAY AFFECT BIDDING.8.GALLON SIZES ARE FOR PRICING PURPOSES ONLY. PLANT MUST MEET HEIGHTS AND WIDTHS SPECIFIEDIN PLANT SCHEDULE.9.ROOT TYPE MAY BE FREELY SUBSTITUTED IN CASE OF BALLED AND BURLAPPED OR CONTAINER GROWN,OTHER SPECIFICATIONS REMAINING UNCHANGED, EXCEPT IN THE CASE OF CONTAINER GROWNSPECIMEN TREES AS INDICATED IN THE TREE PLANTING SCHEDULE.10.ANY SIGNIFICANT ROOTS ENCOUNTERED 2" DIA. AND LARGER SHALL BE DUG OUT BY HAND AND CLEANLY CUT BACK IN THE FOOTING / FOUNDATION AREA TO PROMOTE ROOT RE-GROWTH AND HELP PREVENT ROOT DIEBACK.11.ALL PLANT MATERIAL (EXCEPT SEASONAL COLOR) SHALL BE GUARANTEED AND REPLACED AS NECESSARY BY THE CONTRACTOR FOR ONE YEAR.12.ALL SEASONAL COLOR SHALL BE GUARANTEED AND REPLACED AS NECESSARY BY THE CONTRACTORFOR THREE MONTH TIME FRAMES.
IRRIGATION NOTES:
TURF AND GRASSING NOTES:
1.CONTRACTOR TO SUPPLY AUTOMATIC IRRIGATION SYSTEM, COMPLETE AND INSTALLED. SYSTEM TO INCLUDE ALL VALVES, PIPES, HEADS, FITTINGS, BACK FLOW CONTROLLER, AND IRRIGATION METER AND TO PROVIDE 100% COVERAGE FOR ALL NEW PLANTINGS. DRIP IRRIGATION TO BE USED FOR ALL PLANTINGS, EXCEPT LAWNS.2.NO IRRIGATION COMPONENTS SHALL BE CLOSER THAN 12" TO ANY EDGE OF PAVEMENT OR CURB AND GUTTER. IRRIGATION SHALL NOT SPRAY BEYOND LANDSCAPED AREAS, OR INTO ANY UNDISTURBEDBUFFERS. NO OVER SPRAY SHALL BE PERMITTED ONTO ADJACENT PROPERTIES OR PEDESTRIANSIDEWALK AREAS.3.LANDSCAPE CONTRACTOR TO FIELD VERIFY ALL COMPONENT LOCATIONS TO ENSURE APPROPRIATECOVERAGE.4.LANDSCAPE CONTRACTOR SHALL LOCATE WATER SOURCE AND PROVIDE POWER TO CONTROLLER.5.CONTROLLER LOCATION TO BE SPECIFIED BY OWNERS REPRESENTATIVE IN FIELD PRIOR TO CONSTRUCTION.6.ALL DRIP TUBING SHALL BE COVERED WITH MIN. 3" OF MULCH.7.ALL DRIP AND SPRAY ZONES SHALL BE SEPARATE.8.CONTRACTOR SHALL SUBMIT FINAL IRRIGATION PLANS TO OWNER'S REPRESENTATIVE AND ALL REVIEWING BODIES / AGENCIES FOR FINAL APPROVAL PRIOR TO INSTALLATION.
1.CONTRACTOR SHALL IMPLEMENT ALL SILT FENCE OR OTHER SEDIMENT CONTROL MEASURES AROUNDALL DISTURBED AREAS PRIOR TO ANY CONSTRUCTION ACTIVITIES.2.TEMPORARY CONSTRUCTION ENTRANCE SHALL BE INSTALLED AFTER SILT FENCE AND PRIOR TO ALL OTHER CONSTRUCTION ACTIVITIES.3.ALL SEDIMENT AND EROSION CONTROL DEVICES SHALL BE INSPECTED BY THE CONTRACTOR AT LEASTONCE EVERY FOURTEEN (14) CALENDAR DAYS AND WITHIN 24 HOURS OF THE END OF A STORM EVENTOF 0.5 INCHES OR GREATER. IF SITE INSPECTIONS IDENTIFY B.M.P.S. THAT ARE DAMAGED OR ARE NOT OPERATING EFFECTIVELY, MAINTENANCE MUST BE PERFORMED AS SOON AS PRACTICAL AND BEFORETHE NEXT STORM EVENT IF PRACTICAL.4.CONTRACTOR TO PROVIDE SILT FENCE AND / OR OTHER CONTROL DEVICES, AS MAY BE REQUIRED, TO CONTROL SOIL EROSION DURING UTILITY CONSTRUCTION. ALL DISTURBED AREAS SHALL BE CLEANED,GRADED AND STABILIZED WITH GRASSING IMMEDIATELY AFTER THE UTILITY INSTALLATION. FILL, COVERAND TEMPORARY SEEDING AT THE END OF EACH DAY ARE RECOMMENDED. IF WATER IS ENCOUNTERED WHILE TRENCHING, THE WATER SHOULD BE FILTERED TO REMOVE ANY SEDIMENTSBEFORE BEING PUMPED BACK INTO ANY WATERS OF THE STATE.5.ALL EROSION CONTROL DEVICES SHALL BE PROPERLY MAINTAINED BY THE CONTRACTOR DURING ALL PHASES OF CONSTRUCTION UNTIL THE COMPLETION OF ALL CONSTRUCTION ACTIVITIES AND ALL DISTURBED AREAS HAVE BEEN STABILIZED. ADDITIONAL CONTROL DEVICES MAY BE REQUIRED DURINGCONSTRUCTION IN ORDER TO CONTROL EROSION AND / OR OFFSITE SEDIMENTATION. ALL TEMPORARYCONTROL DEVICES SHALL BE REMOVED ONCE CONSTRUCTION IS COMPLETE AND THE SITE IS STABILIZED.6.THE CONTRACTOR MUST TAKE NECESSARY ACTION TO MINIMIZE THE TRACKING OF MUD ONTO PAVEDSURFACES FROM CONSTRUCTION AREAS AND THE GENERATION OF DUST. THE CONTRACTOR SHALLREMOVE MUD / SOIL DAILY FROM PAVED SURFACES, AS REQUIRED.7.RESIDENTIAL SUBDIVISIONS REQUIRE EROSION CONTROL FEATURES FOR INFRASTRUCTURE AS WELL AS FOR INDIVIDUAL LOT CONSTRUCTION. INDIVIDUAL PROPERTY OWNERS SHALL FOLLOW THESE PLANSDURING CONSTRUCTION OR OBTAIN APPROVAL OF AN INDIVIDUAL PLAN IN ACCORDANCE WITH S.C. REG. 72-300 ET SEQ. AND SCR100000.8.TEMPORARY DIVERSION BERMS AND / OR DITCHES WILL BE PROVIDED AS NEEDED DURINGCONSTRUCTION TO PROTECT WORK AREAS FROM UPSLOPE RUNOFF AND / OR TO DIVERTSEDIMENT-LADEN WATER TO APPROPRIATE TRAPS OR STABLE OUTLETS.9.ALL WATERS OF THE STATE (W.O.S.), INCLUDING WETLANDS, ARE TO BE FLAGGED OR OTHERWISECLEARLY MARKED IN THE FIELD. A DOUBLE ROW OF SILT FENCE IS TO BE INSTALLED IN ALL AREASWHERE A 50-FOOT BUFFER CAN'T BE MAINTAINED BETWEEN THE DISTURBED AREA AND ALL W.O.S. A 10-FOOT BUFFER SHOULD BE MAINTAINED BETWEEN THE LAST ROW OF SILT FENCE AND ALL W.O.S.10.LITTER, CONSTRUCTION DEBRIS, OILS, FUELS AND BUILDING PRODUCTS WITH SIGNIFICANT POTENTIALFOR IMPACT (SUCH AS STOCKPILES OF FRESHLY TREATED LUMBER) AND CONSTRUCTION CHEMICALSTHAT COULD BE EXPOSED TO STORMWATER MUST BE PREVENTED FROM BECOMING A POLLUTANTSOURCE IN STORMWATER DISCHARGES.11.STABILIZATION MEASURES SHALL BE INITIATED AS SOON AS PRACTICAL IN PORTIONS OF THE SITE WHERECONSTRUCTION ACTIVITIES HAVE TEMPORARILY OR PERMANENTLY CEASED, BUT IN NO CASE MORETHAN FOURTEEN (14) DAYS AFTER WORK HAS CEASED EXCEPT AS STATED BELOW:11.1.WHERE STABILIZATION BY THE 14TH DAY IS PRECLUDED BY SNOW COVER OR FROZEN GROUNDCONDITIONS, STABILIZATION MEASURES MUST BE INITIATED AS SOON AS PRACTICAL.11.2.WHERE CONSTRUCTION ACTIVITY ON A PORTION OF THE SITE IS TEMPORARILY CEASED ANDEARTH-DISTUBING ACTIVITIES WILL BE RESUMED WITHIN 14 DAYS, TEMPORARY STABILIZATIONMEASURES DO NOT HAVE TO BE INITIATED ON THAT PORTION OF THE SITE.
GENERAL DISTURBANCE NOTES:
1.CONTRACTOR SHALL VERIFY ALL ELEVATIONS PRIOR TO CONSTRUCTION AND NOTIFY OWNER'SREPRESENTATIVE OF DISCREPANCIES.2.CROSS SLOPES ON ALL HARDSCAPE WALKWAYS / PATHWAYS ARE NOT TO EXCEED 2%.3.ALL ACCESSIBLE WALKWAYS / PATHWAYS RUNNING SLOPE (GRADIENT) MAY NOT EXCEED 4.9%, UNLESSA RAMP IS INSTALLED. IF A RAMP IS INSTALLED THE RUNNING SLOPE (GRADIENT) SHALL NOT EXCEED8.33%, AND HANDRAILS SHALL BE INSTALLED ON BOTH SIDES (MINIMUM 36" CLEARANCE BETWEENHANDRAILS) WHEN RAMP RISE IS GREATER THAN 6".4.IF DISCREPANCIES DEVELOP BETWEEN THE PROPOSED GRADES AS SHOWN ON THE PLAN AND THE EXISTING GROUND SURFACE, THE CONTRACTOR, WITH PRIOR APPROVAL FROM THE OWNER'SREPRESENTATIVE, SHALL MAKE GRADING ADJUSTMENTS NECESSARY TO MAINTAIN THE GENERAL INTENTOF THE DESIGN.5.CONTRACTOR IS RESPONSIBLE FOR ALL PAVED AREAS DAMAGED DURING CONSTRUCTION.6.CONTRACTOR SHALL PROVIDE POSITIVE DRAINAGE AWAY FROM ALL ADJACENT PROPERTIES, WALLS,WALKS AND PLANTING BEDS AND TOWARDS EXISTING DRAIN INLETS, SWALES, STORMWATER LAGOONSOR ROADS.7.ALL DISTURBED AREAS INCLUDING SHALLOW SWALES SHALL BE MULCHED OR PLANTED AS INDICATEDON PLANTING PLANS.8.IF REQUIRED, POP UP EMITTER SHALL BE N.D.S. 6" POP UP DRAINAGE EMITTER BLACK IN COLOR.9.LANDSCAPE DRAIN SHALL BE AS SPECIFIED ON PLANS.10.LANDSCAPE DRAINS SHALL BE ADDED TO PROVIDE POSITIVE DRAINAGE AWAY FROM BUILDINGS IN LOW / FLAT AREAS THAT DID NOT SHOW UP ON THE TOPOGRAPHIC SURVEY. LANDSCAPE DRAIN SHALLBE APPROVED BY OWNER, OWNER'S REPRESENTATIVE OR LANDSCAPE ARCHITECT PRIOR TO INSTALLATION.
1.GRASS SEED: PROVIDE FRESH, CLEAN, NEW-CROP SEED COMPLYING WITH TOLERANCE FOR PURITY AND GERMINATION ESTABLISHED BY OFFICIAL SEED ANALYSIS OF NORTH AMERICA. PROVIDE SEED MIXTURECOMPOSED OF GRASS SPECIES, PROPORTIONS AND MINIMUM PERCENTAGES OF PURITY, GERMINATION,AND MAXIMUM PERCENTAGE OF WEED SEED, AS SPECIFIED SEED MANUFACTURER.2.SOD SHALL BE STRONGLY ROOTED AND FREE OF PERNICIOUS WEEDS. ALL NETTING SHALL BE REMOVEDFROM SOD BEFORE IT IS LAID.3.ALL AREAS IN WHICH EARTHWORK SHALL BE SUSPENDED FOR MORE THAN TWO (2) WEEKS SHALL BE GRASSED WITH TEMPORARY GRASS.4.AFTER TOPSOIL HAS BEEN INSTALLED, AND BEFORE ANY SOD IS LAID, CORRECT ALL SOFT SPOTS AND IRREGULARITIES IN GRADE. THE SOD SHALL BE BE LAID BY BUTTING THE ENDS AND SIDES UP EVENLYAND STAGGERING THE ROLLS OF SOD. CONTRACTOR SHALL NOT OVERLAP SOD. AS SOON AS THE SOD IS LAID OR AS IT IS BEING LAID ROLL OVER WITH A LIGHT ROLLER, MAKING CERTAIN THAT ALL OF THE SOD IS IN CONTACT WITH THE SOIL. THE COMPLETED SODDED AREAS SHALL BE TRUE TO FINISH GRADE,EVEN AND FIRM AT ALL POINTS.5.SEED SHALL BE AT A RATE OF 10 POUNDS PER ACRE.6.THIRTY DAYS AFTER LAST SEEDING/SODDING OPERATION, APPLY 1 POUND OF TYPE A NITROGENFERTILIZER PER ACRE OF LAWN AREAS AND IMMEDIATELY WATER.7.UPON COMPLETION OF PLANTINGS ALL EXCESS SOIL STONES AND DEBRIS WHICH HAS NOT PREVIOUSLYBEEN CLEANED UP SHALL BE REMOVED FROM THE SITE AND DISPOSED OF AS DIRECTED BY THE OWNER'S REPRESENTATIVE.8.ALL LAWN AREAS THAT DO NOT SHOW SATISFACTORY GROWTH WITHIN (18) DAYS AFTER PLANTINGSHALL BE RE-PLANTED AND RE-FERTILISZED AS SPECIFIED UNTIL A SATISFACTORY LAWN IS ESTABLISHED.THE LAWN SHALL BE CONSIDERED ESTABLISHED WHEN ITS REASONABLY FREE FROM WEED, GREEN IN APPEARANCE AND THE SPECIFIED GRASS IS VIGOROUS AND GROWING WELL ON EACH SQ. FT. OF LAWNAREA.9.LAWN SHALL BE PROTECTED AND MAINTAINED BY WATERING, MOWING, AND REPLANTING,OVERSEEING, AS NECESSARY FOR AS LONG AS IS NECESSARY TO ESTABLISH A UNIFORM STAND.SCATTERED BARE SPOTS, NONE OF WHICH IS LARGER THAN ONE SQ. FT., WILL BE ALLOWED UP TO MAXIMUM OF THREE PERCENT OF ANY LAWN AREA. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO REPAIR ANY EROSIONAL DAMAGE TO THE LAWN AREA. FULL COVERAGE IS REQUIREDIN SIXTY DAYS.10.MAINTENANCE OF GRASSED AREAS SHALL CONSIST OF MOWING, WATERING AND FERTILIZING. ALL GRASSED AREAS SHALL BE MAINTAINED AT A HEIGHT NOT TO EXCEED 6" ABOVE FINISHED GRADE.11.IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO MAINTAIN ALL GRASSED AREAS UNTIL ACCEPTANCEBY OWNER AT END OF PROJECT. LAWN MAINTENANCE SHALL OCCUR AT A MINIMUM OF ONCE PER SEVEN CALENDAR DAYS.12.FINAL SEEDING AND SOD AREAS / SQUARE FOOTAGES TO BE PAINTED IN FIELD AND APPROVED AND ADJUSTED IN FIELD BY OWNER'S REPRESENTATIVE PRIOR TO INSTALLATION.13.SEEDING SHALL TAKE PLACE IMMEDIATELY AFTER FINE GRADING. MAINTAIN SEEDED LAWN UNTILCOMPLETION AND ACCEPTANCE OF ENTIRE PROJECT.14.SEEDING BED SHALL HAVE TOPSOIL LOOSEN TO A DEPTH OF 4". REMOVE STONE OVER 1" IN ANY DIMENSION, ROOTS, RUBBISH, AND EXTRANEOUS MATTER.
1.TOPSOIL SHALL CONSIST OF THE NATURAL LOAM, SANDY LOAM, SILT LOAM, OR CLAY LOAM HUMUSBEARING SOILS, ADAPTED TO THE SUSTENANCE OF PLANT LIFE, WITH THE FOLLOWING TEXTURE:1.1.ORGANIC MATERIAL - TWO (2) TO TWENTY (20) PERCENT BY MASS1.2.SAND CONTENT - TWENTY (20) TO SIXTY (60) PERCENT BY MASS1.3.CLAY-SILT CONTENT – THIRTY FIVE (35) TO SEVENTY (70) PERCENT BY MASS.1.4.TOPSOIL PH SHALL BE BETWEEN FIVE (5) AND SEVEN (7).2.TOPSOIL SHALL BE OF UNIFORM QUALITY AND FREE FROM FOREIGN MATERIAL SUCH HARD CLODS,SOD, STIFF CLAY, HARD PAN, STONES LARGER THAN ONE (1) INCH DIAMETER, LIME CEMENT, ASHES,SLAG, CONCRETE, TAR RESIDUES, TARRED PAPER, BOARDS, CHIPS, STICKS, OR OTHER UNDESIRABLEMATERIALS. IT SHALL ALSO BE REASONABLY FREE FROM WEEDS AND OBJECTIONABLE PLANT MATERIAL.3.AFTER ALL DEMOLITION, CLEARING AND DISPOSAL IS COMPLETED, THE CONTRACTOR SHALL STRIP FROMTHE TOP OF THE EXISTING GROUND ALL TOPSOIL IN ALL AREAS TO BE GRADED.4.PRIOR TO STOCKPILING OF TOPSOIL, TOPSOIL SHALL BE SCREENED WITH A ONE HALF (1/2) INCH SIZE SIEVE. STOCKPILE TOPSOIL IN DESIGNATED OR APPROVED LOCATIONS WITH PROPER DRAINAGE AND WHERE IT WILL NOT INTERFERE WITH THE WORK. AFTER TOPSOIL HAS BEEN STOCKPILED, CONTRACTORSHALL QUANTIFY THE AMOUNTS AT NO ADDITIONAL COST TO THE OWNER. QUANTITIES SHALL BE GIVEN TO THE ARCHITECT, OWNER AND SITE DESIGN PROFESSIONAL.5.IF AMOUNT OF SCREENED TOPSOIL STOCKPILED FROM STRIPING OPERATIONS IS INSUFFICIENT TO PROVIDE THE NECESSARY AMOUNTS (4" MINIMUM DEPTH), IT SHALL BE THE CONTRACTOR’S RESPONSIBILITY TO OBTAIN (FROM OFF-SITE SOURCE) THE NECESSARY AMOUNT OF SCREENED TOPSOILTO COMPLETE THE PROJECT.6.SCREENED TOPSOIL SHALL BE DISTRIBUTED WITH A MINIMUM DEPTH OF FOUR (4) INCHES TO ALL GRADED AREAS (NOT INCLUDING BUILDING, PAVED, SYNTHETIC TURF, PERVIOUS PAVEMENT, ETC.) AND / OR AS DIRECTED BY THE OWNER OR OWNER'S REPRESENTATIVE. GROUND SHALL BE SCARIFIED BEFOREPLACING TOPSOIL. AREAS WHERE SCREENED TOPSOIL IS DISTRIBUTED SHALL BE STABILIZED WITH TEMPORARY AND/OR PERMANENT VEGETATION (SEASON DEPENDENT) OR TEMPORARY MULCH WITHINFOURTEEN (14) CALENDAR DAYS OF DISTRIBUTION.
SOIL AMENDMENT NOTES:
Page 51 of 69
26 DBH LIVE OAK (SIGNIFICANT TREE) - EXISTING CANOPY IMPACT: 33%5 9 10 11 13 16 17 DBH LIVE OAK (SPECIMEN TREE) - EXISTING CANOPY IMPACT: 69% 13 16 19 DBH LIVE OAK (SIGNIFICANT TREE) - EXISTING CANOPYIMPACT: 48%26 DBH LIVE OAK (SIGNIFICANT TREE) - EXISTING CANOPY IMPACT: 79%15 22 DBH LIVE OAK (SIGNIFICANT TREE) - EXISTING CANOPY IMPACT: 3%24 DBH LIVE OAK (SIGNIFICANT TREE) - EXISTING CANOPY IMPACT: 12%
SPECIMEN AND SIGNIFICANT TREEENCROACHMENT SUMMARY:ABDCE
REFERENCE PLANEXISTING CONDITIONS
SITE DEVELOPMENT PLANSFORMEMORY MATTERSHILTON HEAD ISLAND, SOUTH CAROLINA
DRAWING NUMBERDRAWING TITLE
DESIGN CONCEPTS, DRAWING, SHEETS,LOGOS, SPECIFICATIONS, DETAILS,WRITTEN MATERIAL SHALL NOT BE USEDOR REPRODUCED IN WHOLE OR IN PARTIN ANY FORM WITHOUT PRIOR WRITTENCONSENT OF WJK LTD.© 2026 WJK LTD.THIS SHEET TO SCALE AT: 24"X36"
DATE:PROJECT NO.:DRAWN BY:CHECKED BY:JUL 29, 202626056.01SDJC
REVISIONS:DRB SUBMITTALPLAN, NOT FORCONSTRUCTION
L10
MEMORY MATTERSBUILDING
02040608010305070Scale 1 " = 20'cNEW
LAGOON
PROPERTY LINE20' ADJACENT USE SETBACK
PROPERTY LINEBIKE PATH EASEMENT
40' ADJACENT STREET SETBACK
PROPERTY LINE
PROPERTY LINE
20' ADJACENT STREET SETBACKPROPERTY LINE
LOT 17
LOT 19TRELLIS COURT
LEG OF MUTTON ROAD
MARSHLAND ROAD
EXISTING CONDITIONS REFERENCENOTES:1EXISTING PERVIOUS SURFACE (LANDSCAPE AREAS).EXISTING PERVIOUS SURFACE - PERVIOUS PAVERS.EXISTING IMPERVIOUS SURFACE - CONCRETE.ENTRY AND EXIT LANE.EXISTING DOCK.EXISTING BULKHEAD.EXISTING PLANTER.EXISTING UTILITIES.FLOOD ZONE.EXISTING STORM PIPE.
2345678PROJECT INFORMATION:ZONINGZONING DISTRICT: LIGHT INDUSTRIAL (IL)OVERLAY DISTRICT: OCRM HIGH TIDE LINE (COR)USE OF PROPERTY: OTHER COMMERCIALSITEGROSS SITE ACREAGE: 2.39 ACNET SITE ACREAGE: 2.39 ACAREA OF DISTURBANCE: <0.5 ACDENSITYALLOWED TOTAL DENSITY: 23,900 GFA (10,000 GFA PER ACRE)EXISTING BUILDING SQUARE FOOTAGE: +/- 7,970PROPOSED BUILDING SQUARE FOOTAGE: +/- 8,635BUILDING HEIGHTMAXIMUM HEIGHT ALLOWED: 35'PROPOSED BUILDING HEIGHT: AS EXISTING <35'SITE IMPERVIOUSMAXIMUM ALLOWED IMPERVIOUS AREA: 67,546 SF (65% OF SITE)CURRENT IMPERVIOUS AREA: 52,132 SF (50% OF SITE)PROPOSED IMPERVIOUS AREA: 55,939 SF (54%)PARKINGMINIMUM NUMBER OF PARKING SPACES REQUIRED: 1 PER 350 GFAEXISTING NUMBER OF PARKING SPACES: 22PROPOSED NUMBER OF PARKING SPACES: 22FLOOD ZONE ZONE 'X-SHADED' SHOWN ON HHI FEMA 2021 MAP
EXISTINGPARKING
EXISTINGUNLOADZONE
BIKE PATH
EXISTING GRAVELPAD / SITTING AREA
1
2 3
5
68
9
79
TREE IMPACT LEGENDSYMBOLDESCRIPTIONTREE CANOPY - SPECIMENSPECIMEN TREE IMPACTS - EXISTINGSIGNIFICANT TREE IMPACTS - EXISTINGNOTE: HATCHES ARE GRAPHIC IN NATURE AND ARE NOT INTENDED TO BE TO SCALE.LOWEST LIMB WITH CLEARANCE FROM GRADE+12'TREE CANOPY - SIGNIFICANT
A BDC EF
F
EXISTINGSTORMPAVERS
40' ADJACENT STREET SETBACK
20' ADJACENT USE SETBACK
SOUTHERN BOUNDARY (325 LF) - MARSHLAND ROADTYPE 'B' OPTION 1 (25') MINOR ARTERIAL BUFFER
WESTERN BOUNDARY (139 LF) - LEG OF MUTTON ROADTYPE 'B' OPTION 1 (25') MINOR ARTERIAL BUFFER
NORTHWESTERN BOUNDARY (282 LF) - SHARED INDUSTRIAL (IL ZONING) PROPERTYLINENO EXTERIOR BOUNDARY BUFFER REQUIRED
4NORTHERN BOUNDARY(90 LF) - TRELIS COURTTYPE 'A' OPTION 1 (20')ADJACENTSTREET BUFFEREASTERN BOUNDARY (235 LF) - SHARED INDUSTRIAL (IL ZONING) PROPERTY LINENO EXTERIOR BOUNDARY BUFFER REQUIRED
10
10
EXISTINGVEGETATIONTO REMAIN, TYP.
EXISTINGVEGETATIONTO REMAIN, TYP.
Page 52 of 69
SITE PHOTOSEXISTING CONDITIONS
SITE DEVELOPMENT PLANSFORMEMORY MATTERSHILTON HEAD ISLAND, SOUTH CAROLINA
DRAWING NUMBERDRAWING TITLE
DESIGN CONCEPTS, DRAWING, SHEETS,LOGOS, SPECIFICATIONS, DETAILS,WRITTEN MATERIAL SHALL NOT BE USEDOR REPRODUCED IN WHOLE OR IN PARTIN ANY FORM WITHOUT PRIOR WRITTENCONSENT OF WJK LTD.© 2026 WJK LTD.THIS SHEET TO SCALE AT: 24"X36"
DATE:PROJECT NO.:DRAWN BY:CHECKED BY:JUL 29, 202626056.01SDJC
REVISIONS:DRB SUBMITTALPLAN, NOT FORCONSTRUCTION
L11
MEMORY MATTERSBUILDING
cNEW
LAGOON
PROPERTY LINE20' ADJACENT USE SETBACK
PROPERTY LINEBIKE PATH EASEMENT
40' ADJACENT STREET SETBACK
PROPERTY LINE
PROPERTY LINE
20' ADJACENT STREET SETBACKPROPERTY LINE
LOT 17
LOT 19TRELLIS COURT
LEG OF MUTTON ROAD
MARSHLAND ROAD
EXISTINGPARKING
EXISTINGUNLOADZONE
BIKE PATH
40' ADJACENT STREET SETBACK
20' ADJACENT USE SETBACK
EXISTINGVEGETATIONTO REMAIN, TYP.
EXISTINGVEGETATIONTO REMAIN, TYP.
EXISTINGPARKING
040801201602060100140Scale 1 " = 40'
1ONLY VIEW INTO SITE FROM MARSHLAND ROAD
4VIEW INTO SITE FROM TRELLIS COURT ENTRY
2INTERNAL VIEW TO MARSHLAND ROAD
5BUILDING FRONTAGE AND PARKING LOT LIVE OAKS
3INTERNAL VIEW TO LEG O'MUTTON ROAD
6BUILDING FRONT AND PERVIOUS PARKING
7LAGOON BULKHEAD WALL8FUTURE GARDEN SPACE AND WATER OAK TO REMAIN
9PERVIOUS PARKING SURFACE10BUILDING FRONTAGE
1 23
45 7 8106
Page 53 of 69
G
DEMOLITION PLANL50
SITE DEVELOPMENT PLANSFORMEMORY MATTERSHILTON HEAD ISLAND, SOUTH CAROLINA
DRAWING NUMBERDRAWING TITLE
DESIGN CONCEPTS, DRAWING, SHEETS,LOGOS, SPECIFICATIONS, DETAILS,WRITTEN MATERIAL SHALL NOT BE USEDOR REPRODUCED IN WHOLE OR IN PARTIN ANY FORM WITHOUT PRIOR WRITTENCONSENT OF WJK LTD.© 2026 WJK LTD.THIS SHEET TO SCALE AT: 24"X36"
DATE:PROJECT NO.:DRAWN BY:CHECKED BY:JUL 29, 202626056.01SDJC
REVISIONS:DRB SUBMITTALPLAN, NOT FORCONSTRUCTION
MEMORY MATTERSBUILDING
LAGOON
PROPERTY LINE
PROPERTY LINEBIKE PATH EASEMENT
PROPERTY LINE
PROPERTY LINE
PROPERTY LINE
LOT 17
LOT 19TRELLIS COURT
LEG OF MUTTON ROAD
MARSHLAND ROAD
cNEW02040608010305070Scale 1 " = 20'
SITE DEMOLITION LEGENDSYMB.DESCRIPTIONTREE TO BE REMOVED- SEE SHEET L500 & L501 FOR MITIGATIONCALL-OUTNOTE: DEMOLITION HATCHES ARE GRAPHIC IN NATURE AND ARE NOT INTENDED TO BE TOSCALE.2.2SILT FENCE2.12.3DEMOLITION LIMITS
PLANT PROTECTION LEGENDSYMB.DETAILDESCRIPTIONCALL-OUT1.1TREE PROTECTION FENCE - WOOD1/L6001.2TREE PROTECTION FENCE - ALT (ORANGE)1/L600
DEMOLITION REFERENCE NOTES:1PROTECT EXISTING PAVEMENT(S) DURING CONSTRUCTION.PAVEMENT TO BE MAINTAINED AND INTEGRATED WITH NEWCONSTRUCTION.EXISTING TREE TO REMAIN, DO NOT DISTURB, PROTECT IN PLACE.REVIEW HEALTH OF EXISTING TREE WITH ARBORIST PRIOR TOREMOVAL OF EXISTING PAVEMENT WITHIN DRIP LINE. FOLLOWARBORISTS INSTRUCTION FOR PAVEMENT REMOVAL TO MINIMIZEDAMAGE TO TREE ROOTS. REPORT ANY CONFLICTS TOLANDSCAPE ARCHITECT.EXISTING TREE TO BE REMOVED INCLUDING ROOTS AND STUMP,LEGALLY DISPOSE OF OFF SITE.EXISTING LANDSCAPING TO BE REMOVED INCLUDING ROOTS ANDSTUMPS. REMOVE ANY AND ALL MULCH / ROCK. LEGALLY DISPOSEOF OFF SITE.CLEAN AND CLEAR AREA OF ALL TRASH, LANDSCAPE DEBRIS, ANDANY ADDITIONAL LANDSCAPING. LEGALLY DISPOSE OF OFF SITE.LIMIT GRADING WITHIN TREE PROTECTION FENCE AREA TO HANDDIGGING, TAKING CARE NOT TO DISTURB ROOTS.MITIGATE SOIL COMPACTION WITH 12" OF HARDWOOD MULCHBETWEEN TREE PROTECTION FENCE AND STRUCTURE.PROVIDE A DESIGNATED CONCRETE WASHOUT AREA IN ANAPPROVED LOCATION. PREVENT DISCHARGE OF WASHOUTMATERIALS TO STORM DRAINS OR ADJACENT AREAS.
24356789
20' ADJACENT USE SETBACK
40' ADJACENT STREET SETBACK
20' ADJACENT STREET SETBACK
40' ADJACENT STREET SETBACK
20' ADJACENT USE SETBACK
SOUTHERN BOUNDARY (325 LF) - MARSHLAND ROADTYPE 'B' OPTION 1 (25') MINOR ARTERIAL BUFFER
WESTERN BOUNDARY (139 LF) - LEG OF MUTTON ROADTYPE 'B' OPTION 1 (25') MINOR ARTERIAL BUFFER
NORTHWESTERN BOUNDARY (282 LF) - SHARED INDUSTRIAL (IL ZONING) PROPERTYLINENO EXTERIOR BOUNDARY BUFFER REQUIRED
NORTHERN BOUNDARY(90 LF) - TRELIS COURTTYPE 'A' OPTION 1 (20')ADJACENTSTREET BUFFER
EASTERN BOUNDARY (235 LF) - SHARED INDUSTRIAL (IL ZONING) PROPERTY LINENO EXTERIOR BOUNDARY BUFFER REQUIRED
EXISTINGVEGETATIONTO REMAIN, TYP.
EXISTINGVEGETATIONTO REMAIN, TYP.
G1.3TYPE G IMPERVIOUS INLET PROTECTION
1.1TYP.1.2TYP.
1.3TYP.
2.1TYP.2.2TYP.2.3TYP.
1TYP.3TYP.
4TYP.
5TYP.6TYP.
7TYP.8TYP.
9TYP. MOVEABLE DUMPSTER, TYP.
NA
Page 54 of 69
26 DBH LIVE OAK (SIGNIFICANT TREE) - PROPOSED CANOPY IMPACT: 33%5 9 10 11 13 16 17 DBH LIVE OAK (SPECIMEN TREE) - PROPOSED CANOPY IMPACT: 71%13 16 19 DBH LIVE OAK (SIGNIFICANT TREE) - PROPOSED CANOPY IMPACT:50%26 DBH LIVE OAK (SIGNIFICANT TREE) - PROPOSED CANOPY IMPACT: 80%15 22 DBH LIVE OAK (SIGNIFICANT TREE) - PROPOSED CANOPY IMPACT: 16%
SPECIMEN AND SIGNIFICANT TREEENCROACHMENT SUMMARY:
24 DBH LIVE OAK (SIGNIFICANT TREE) - PROPOSED CANOPY IMPACT: 9%ABDCEFLAYOUT PLANL200
SITE DEVELOPMENT PLANSFORMEMORY MATTERSHILTON HEAD ISLAND, SOUTH CAROLINA
DRAWING NUMBERDRAWING TITLE
DESIGN CONCEPTS, DRAWING, SHEETS,LOGOS, SPECIFICATIONS, DETAILS,WRITTEN MATERIAL SHALL NOT BE USEDOR REPRODUCED IN WHOLE OR IN PARTIN ANY FORM WITHOUT PRIOR WRITTENCONSENT OF WJK LTD.© 2026 WJK LTD.THIS SHEET TO SCALE AT: 24"X36"
DATE:PROJECT NO.:DRAWN BY:CHECKED BY:JUL 29, 202626056.01SDJC
REVISIONS:DRB SUBMITTALPLAN, NOT FORCONSTRUCTION
MEMORY MATTERSBUILDING
LAGOON
PROPERTY LINE
PROPERTY LINEBIKE PATH EASEMENT
PROPERTY LINE
PROPERTY LINE
PROPERTY LINE
LOT 17
LOT 19TRELLIS COURT
LEG OF MUTTON ROAD
MARSHLAND ROAD
cNEW02040608010305070Scale 1 " = 20'
KEY SHEET REFERENCE NOTES:1PLANTING AREA, TYP., REFER TO PLANTING PLANSMAINTAIN EXISTING ENTRANCE ACCESS.MAINTAIN EXISTING PERMEABLE PAVER DRIVE, CONTRACTORRESPONSIBLE FOR REPLACEMENT / REPAIR OF ANY AND ALLDAMAGES.TIE PROPOSED WALK INTO EXISTING PARKING LOT EVENLY ANDSMOOTHLY.PROPOSED IMPROVEMENTS BY OTHERS, N.I.C., SHOWN FORREFERENCE ONLY. COORDINATE WITH ARCHITECT AS REQUIRED.A.D.A ACCESSIBLE PARKING PROVIDED NEAR RAMP ENTRANCE.243P.A.
EXISTINGPAVE DRIVE
EXISTINGSTORMPAVER DRIVE
SITE HARDSCAPE LEGENDSYMB.DETAILDESCRIPTIONCALL-OUT2.2BRICK PAVERSTABBY CONCRETE2.35/L6002.1GRANITE FINES4/L600SITE DETAILS LEGENDDETAILDESCRIPTION9.1CALL-OUT7.2FENCE7/L6001/L6012/L6017.1GATEARBOR
BORDERS, REFER TO DETAILS 3/L600,4/L600NANA 2.4
20' ADJACENT USE SETBACK
40' ADJACENT STREET SETBACK
20' ADJACENT STREET SETBACK
40' ADJACENT STREET SETBACK
20' ADJACENT USE SETBACK
SOUTHERN BOUNDARY (325 LF) - MARSHLAND ROADTYPE 'B' OPTION 1 (25') MINOR ARTERIAL BUFFER
WESTERN BOUNDARY (139 LF) - LEG OF MUTTON ROADTYPE 'B' OPTION 1 (25') MINOR ARTERIAL BUFFER
NORTHWESTERN BOUNDARY (282 LF) - SHARED INDUSTRIAL (IL ZONING) PROPERTYLINENO EXTERIOR BOUNDARY BUFFER REQUIRED
NORTHERN BOUNDARY(90 LF) - TRELIS COURTTYPE 'A' OPTION 1 (20')ADJACENTSTREET BUFFEREASTERN BOUNDARY (235 LF) - SHARED INDUSTRIAL (IL ZONING) PROPERTY LINENO EXTERIOR BOUNDARY BUFFER REQUIRED
EXISTINGVEGETATIONTO REMAIN, TYP.
EXISTINGVEGETATIONTO REMAIN, TYP.
PROJECT INFORMATION:ZONINGZONING DISTRICT: LIGHT INDUSTRIAL (IL)OVERLAY DISTRICT: OCRM HIGH TIDE LINE (COR)USE OF PROPERTY: OTHER COMMERCIALSITEGROSS SITE ACREAGE: 2.39 ACNET SITE ACREAGE: 2.39 ACAREA OF DISTURBANCE: <0.5 ACDENSITYALLOWED TOTAL DENSITY: 23,900 GFA (10,000 GFA PER ACRE)EXISTING BUILDING SQUARE FOOTAGE: +/- 7,970PROPOSED BUILDING SQUARE FOOTAGE: +/- 8,635BUILDING HEIGHTMAXIMUM HEIGHT ALLOWED: 35'PROPOSED BUILDING HEIGHT: AS EXISTING <35'SITE IMPERVIOUSMAXIMUM ALLOWED IMPERVIOUS AREA: 67,546 SF (65% OF SITE)CURRENT IMPERVIOUS AREA: 52,132 SF (50% OF SITE)PROPOSED IMPERVIOUS AREA: 55,939 SF (54%)PARKINGMINIMUM NUMBER OF PARKING SPACES REQUIRED: 1 PER 350 GFAEXISTING NUMBER OF PARKING SPACES: 22PROPOSED NUMBER OF PARKING SPACES: 22FLOOD ZONE ZONE 'X-SHADED' SHOWN ON HHI FEMA 2021 MAP
CONCRETE STAIRS
GATE WITHELECTRONIC BY-PASS
GATE WITHELECTRONIC BY-PASS
GATE WITHELECTRONIC BY-PASS
ENTRY SIGNAGEBY OWNERDONORPLAQUETBDEXISTING PLANTINGBED TO REMAIN
2.3TYP.2.1TYP.
2.2TYP.7.1TYP.7.2TYP.9.1TYP.
SITE FURNITUREBY OWNERBENCHES WILL BEANCHORED TOCONCRETE PADS, TYP.ENGRAVEDPAVER WALKTBD ENGRAVEDFOUNDERS RINGTBDP.A.
P.A.TYP.1
2TYP.3TYP.4TYP.
3/L600
6/L600
DUMPSTERENCLOSURESEE ARCHITECT'S PLANS
GENERATOR, SEEARCHITECT'S PLANS
350 GAL. BURIEDPROPANE TANK
5 2.4TYP.
FOOD DELIVERY PARKINGTO MATCH EXISTINGDRIVE
A BDC EF5TYP.
Page 55 of 69
GRADING PLANL300
SITE DEVELOPMENT PLANSFORMEMORY MATTERSHILTON HEAD ISLAND, SOUTH CAROLINA
DRAWING NUMBERDRAWING TITLE
DESIGN CONCEPTS, DRAWING, SHEETS,LOGOS, SPECIFICATIONS, DETAILS,WRITTEN MATERIAL SHALL NOT BE USEDOR REPRODUCED IN WHOLE OR IN PARTIN ANY FORM WITHOUT PRIOR WRITTENCONSENT OF WJK LTD.© 2026 WJK LTD.THIS SHEET TO SCALE AT: 24"X36"
DATE:PROJECT NO.:DRAWN BY:CHECKED BY:JUL 29, 202626056.01SDJC
REVISIONS:DRB SUBMITTALPLAN, NOT FORCONSTRUCTION
GRADING ABBREVIATIONSDESCRIPTIONABBR.DESCRIPTIONFINISHED FLOORELEVATIONFFETOP OF DRAINRIMHIGH POINTHP
LOW POINTLPBOTTOM OF STEPBSTOP OF STEPTSBOTTOM OF WALLBWTOP OF WALLTWABBR.BOTTOM OF CURBBCFINISHED GRADEFGTOP OF CURBTC
GRADING LEGENDSYMB.DESCRIPTIONSPOT GRADEDRAINAGE ARROWPROPOSED CONTOUR MAJORPROPOSED CONTOUR MINOREXISTING GRADE
GRADING REFERENCE NOTES:1MINIMIZE DISTURBANCE AROUND TREES TO REMAIN.PITCH TO DRAIN INLET AT 1% MIN., 2% MAX.PROVIDE 2% MAX. SLOPE IN ALL DIRECTIONS.A.D.A. RAMP AT 1:12 MAX.CONTRACTOR SHALL TIE GUTTER DOWNSPOUTS INTOSUBSURFACE DRAINAGE SYSTEM WHENEVER POSSIBLE.TIE INTO EXISTING GRADE. MEET SMOOTHLY AND EVENLY.MAINTAIN EXISTING DRAINAGE PATTERN AWAY FROM BUILDING.DIRECT STORMWATER TOWARDS STREET OR EXISTING DRAINAGEDITCH, DRAINAGE SHALL NOT BE DIRECTED TOWARDS ADJACENTPROPERTY. CONTRACTOR SHALL PROVIDE SUPPLEMENTALAREA DRAINS, FRENCH DRAINS, AND DRY WELLS AS REQUIREDTO PROMOTE PROPER STORMWATER DRAINAGE, REFER TODETAILS.
2435678
MEMORY MATTERSBUILDING
LAGOON
PROPERTY LINE
PROPERTY LINEBIKE PATH EASEMENT
PROPERTY LINE
PROPERTY LINE
PROPERTY LINE
LOT 17
LOT 19TRELLIS COURT
LEG OF MUTTON ROAD
MARSHLAND ROAD
cNEW02040608010305070Scale 1 " = 20'
20' ADJACENT USE SETBACK
40' ADJACENT STREET SETBACK
20' ADJACENT STREET SETBACK
40' ADJACENT STREET SETBACK
20' ADJACENT USE SETBACK
SOUTHERN BOUNDARY (325 LF) - MARSHLAND ROADTYPE 'B' OPTION 1 (25') MINOR ARTERIAL BUFFER
WESTERN BOUNDARY (139 LF) - LEG OF MUTTON ROADTYPE 'B' OPTION 1 (25') MINOR ARTERIAL BUFFER
NORTHWESTERN BOUNDARY (282 LF) - SHARED INDUSTRIAL (IL ZONING) PROPERTYLINENO EXTERIOR BOUNDARY BUFFER REQUIRED
NORTHERN BOUNDARY(90 LF) - TRELIS COURTTYPE 'A' OPTION 1 (20')ADJACENTSTREET BUFFEREASTERN BOUNDARY (235 LF) - SHARED INDUSTRIAL (IL ZONING) PROPERTY LINENO EXTERIOR BOUNDARY BUFFER REQUIRED
EXISTINGVEGETATIONTO REMAIN, TYP.
EXISTINGVEGETATIONTO REMAIN, TYP.
11.912.212.214.313.513.513.314.314.314.214.112.712.6TC 13.113.313.012.7 11.911.912.011.012.012.412.4512.5
12.412.512.714.31213 12
12141413 1TYP.
122TYP.
3TYP.4TYP.
5TYP. 6TYP.7TYP.
8TYP.
Page 56 of 69
UTILITY PLANL400
SITE DEVELOPMENT PLANSFORMEMORY MATTERSHILTON HEAD ISLAND, SOUTH CAROLINA
DRAWING NUMBERDRAWING TITLE
DESIGN CONCEPTS, DRAWING, SHEETS,LOGOS, SPECIFICATIONS, DETAILS,WRITTEN MATERIAL SHALL NOT BE USEDOR REPRODUCED IN WHOLE OR IN PARTIN ANY FORM WITHOUT PRIOR WRITTENCONSENT OF WJK LTD.© 2026 WJK LTD.THIS SHEET TO SCALE AT: 24"X36"
DATE:PROJECT NO.:DRAWN BY:CHECKED BY:JUL 29, 202626056.01SDJC
REVISIONS:DRB SUBMITTALPLAN, NOT FORCONSTRUCTION
MEMORY MATTERSBUILDING
LAGOON
PROPERTY LINE
PROPERTY LINEBIKE PATH EASEMENT
PROPERTY LINE
PROPERTY LINE
PROPERTY LINE
LOT 17
LOT 19TRELLIS COURT
LEG OF MUTTON ROAD
MARSHLAND ROAD
cNEW02040608010305070Scale 1 " = 20'
SODSOD
20' ADJACENT USE SETBACK
40' ADJACENT STREET SETBACK
20' ADJACENT STREET SETBACK
40' ADJACENT STREET SETBACK
20' ADJACENT USE SETBACK
SOUTHERN BOUNDARY (325 LF) - MARSHLAND ROADTYPE 'B' OPTION 1 (25') MINOR ARTERIAL BUFFER
WESTERN BOUNDARY (139 LF) - LEG OF MUTTON ROADTYPE 'B' OPTION 1 (25') MINOR ARTERIAL BUFFER
NORTHWESTERN BOUNDARY (282 LF) - SHARED INDUSTRIAL (IL ZONING) PROPERTYLINENO EXTERIOR BOUNDARY BUFFER REQUIRED
NORTHERN BOUNDARY(90 LF) - TRELIS COURTTYPE 'A' OPTION 1 (20')ADJACENTSTREET BUFFEREASTERN BOUNDARY (235 LF) - SHARED INDUSTRIAL (IL ZONING) PROPERTY LINENO EXTERIOR BOUNDARY BUFFER REQUIRED
LIGHTING SCHEDULESYMB.DETAIL3/L60110.1CALL-OUT4/L6015/L6011/L60210.210.310.4DESCRIPTIONPATH LIGHTQTY.37223UP LIGHTSTEP LIGHT5POST LIGHTLIGHTING / UTILITY REFERENCE NOTES:1243SPACE LIGHTS EQUALLY AS SHOWN.ADJUST LAMP ORIENTATION IN FIELD PER LANDSCAPEARCHITECTS INSTRUCTION.4" P.V.C. SLEEVE FOR ELECTRICAL CONDUIT AND WIRING. PLACE AMINIMUM OF 12" UNDER BOTTOM OF PAVING SURFACE.LIGHTING CONTROL SYSTEM TO BE COORDINATED WITHARCHITECTS BUILDING CONTROL SYSTEMS. TIMER BASED WITHMANUAL OVERRIDE FOR SPECIAL EVENTS.NOTE: PARKING LOT LIGHTING TO REMAIN.
10.1TYP.10.2TYP.
10.3TYP. 10.4TYP.1TYP.2TYP.
3TYP.
4TYP.
5
Page 57 of 69
PLANTING PLANL500
SITE DEVELOPMENT PLANSFORMEMORY MATTERSHILTON HEAD ISLAND, SOUTH CAROLINA
DRAWING NUMBERDRAWING TITLE
DESIGN CONCEPTS, DRAWING, SHEETS,LOGOS, SPECIFICATIONS, DETAILS,WRITTEN MATERIAL SHALL NOT BE USEDOR REPRODUCED IN WHOLE OR IN PARTIN ANY FORM WITHOUT PRIOR WRITTENCONSENT OF WJK LTD.© 2026 WJK LTD.THIS SHEET TO SCALE AT: 24"X36"
DATE:PROJECT NO.:DRAWN BY:CHECKED BY:JUL 29, 202626056.01SDJC
REVISIONS:DRB SUBMITTALPLAN, NOT FORCONSTRUCTION
PLANT KEY LEGENDPLANTING DETAILSDETAILDESCRIPTIONTREE PLANTING14.1CALL-OUT14.214.3PALM TREE PLANTINGSHRUB PLANTING14.4GROUND COVER PLANTING1/L5012/L5013/L5014/L501
PLANTING REFERENCE NOTES:1EXISTING VEGETATION TO REMAIN.EXISTING TREES TO REMAIN.EXISTING TREES TO BE REMOVED.UNDISTURBED BUFFER.CAREFULLY EXCAVATE SHRUB PITS IN VICINITY OF EXISTING TREES,WITHOUT DISTURBING TREE ROOTS.COORDINATE SHRUB LAYOUT WITH EXISTING UTILITIES. REPORTANY CONFLICTS TO LANDSCAPE ARCHITECT.24356
MEMORY MATTERSBUILDING
LAGOON
PROPERTY LINE
PROPERTY LINEBIKE PATH EASEMENT
PROPERTY LINE
PROPERTY LINE
PROPERTY LINE
LOT 17
LOT 19TRELLIS COURT
LEG OF MUTTON ROAD
MARSHLAND ROAD
cNEW02040608010305070Scale 1 " = 20'
1 QUEV
3 HYLL
6 SERR
2 CHAH10 PLUA1 CAMS9 LOPD
SODSOD3 ILLP15 LIRE1 QUEV5 LANC1 SABP5 ILEN4 HYDE9 PODM20 OPHJ
1 QUEV8 VIBS19 PODM3 OSMF15 FARG
20' ADJACENT USE SETBACK
40' ADJACENT STREET SETBACK
20' ADJACENT STREET SETBACK
40' ADJACENT STREET SETBACK
20' ADJACENT USE SETBACK
SOUTHERN BOUNDARY (325 LF) - MARSHLAND ROADTYPE 'B' OPTION 1 (25') MINOR ARTERIAL BUFFER
WESTERN BOUNDARY (139 LF) - LEG OF MUTTON ROADTYPE 'B' OPTION 1 (25') MINOR ARTERIAL BUFFER
NORTHWESTERN BOUNDARY (282 LF) - SHARED INDUSTRIAL (IL ZONING) PROPERTYLINENO EXTERIOR BOUNDARY BUFFER REQUIRED
NORTHERN BOUNDARY(90 LF) - TRELIS COURTTYPE 'A' OPTION 1 (20')ADJACENTSTREET BUFFEREASTERN BOUNDARY (235 LF) - SHARED INDUSTRIAL (IL ZONING) PROPERTY LINENO EXTERIOR BOUNDARY BUFFER REQUIRED
EXISTINGVEGETATIONTO REMAIN, TYP.
EXISTINGVEGETATIONTO REMAIN, TYP.
1 QUEV
3 SERR
3 SERR7 ILEV5 ILLP3 ILLP3 ILEN1 ILEV3 ILEN3 ILLP3 AZAE3 AZAE1 MAGV3 AZAE3 ILLP2 VIBS3 ILLP3 HYDE
3 ILEV5 LANC3 AZAE3 ILEN5 PLUA5 PLUA2 ILEN3 AZAE7 AZAE3 ILEN5 PODM6 AZAE3 SERR
1 SABP5 LANC13 PODM3 ILEN4 PODM3 LOPD
10 LANC
10 FARJ
11 ILEN10 LIRE3 SERR1 MAGV3 AZAE3 HYLL10 LIRE
6 ILEN9 LOPD
3 HYLL10 LIRE1 OSMF15 FARJ1 CAMS3 HYLL10 PODM
3 LAGN10 FARG
10 LANC3 CAMS3 SERR2 AZAE6 ILEN
14.1TYP.
14.2TYP.
14.3TYP.
14.4TYP.
12
3TYP. 5TYP.
6
2 TRAJ20 LANC
2 CAMS
5 FARJ
1 MAGV
20 LANC6 ILLP
Page 58 of 69
PLANT SCHEDULE ANDDETAILSL501
SITE DEVELOPMENT PLANSFORMEMORY MATTERSHILTON HEAD ISLAND, SOUTH CAROLINA
DRAWING NUMBERDRAWING TITLE
DESIGN CONCEPTS, DRAWING, SHEETS,LOGOS, SPECIFICATIONS, DETAILS,WRITTEN MATERIAL SHALL NOT BE USEDOR REPRODUCED IN WHOLE OR IN PARTIN ANY FORM WITHOUT PRIOR WRITTENCONSENT OF WJK LTD.© 2026 WJK LTD.THIS SHEET TO SCALE AT: 24"X36"
DATE:PROJECT NO.:DRAWN BY:CHECKED BY:JUL 29, 202626056.01SDJC
REVISIONS:DRB SUBMITTALPLAN, NOT FORCONSTRUCTION
1L501TREE PLANTINGSCALE: N.T.S.2L501PALM TREE PLANTINGSCALE: N.T.S.
3L501SHRUB PLANTINGSCALE: N.T.S.4L501GROUND COVER PLANTINGSCALE: N.T.S.5L501TREE STAKINGSCALE: N.T.S.
PLANT SCHEDULE:
PLANT TABLE:
BLACK RUBBER HOSE120°120°120°PLANDOUBLE STRAND 12 GAUGEWIREPROTECT TREE TRUNK WITH BLACK RUBBERHOSE OR APPROVED EQUALDOUBLE STRAND 12 GAUGE WIRE WITHGALVANIZED TURNBUCKLE OR APPROVEDEQUAL. MARK AS HAZARD IN LOCATIONWITH HIGH PEDESTRIAN TRAFFIC3" MINIMUM MULCH DEPTH, REFER TO PLANTSCHEDULE FOR TYPESOIL BERM TO HOLD WATERTREE 2"X4" STAKES (36" LONG) BURIED BELOWFINISH GRADE - ENSURE STAKES ARE MARKEDTO SIGNIFY HAZARD IN LOCATIONS WITHHIGH PEDESTRIAN TRAFFICFINISH GRADEB&B OR CONTAINERIZED (REFER TO PLANTSCHEDULE)SCARIFY SIDES OF HOLE TO 4" DEPTH MINIMUMAMENDED PLANTING SOIL AS NEEDED PERSOIL ANALYSISCOMPACT PLANTING SOIL BENEATHROOTBALLNOTES:1.TREE STAKING OPTIONAL, HOWEVER, LANDSCAPE CONTRACTOR RESPONSIBLE FOR MAINTAINING TREES IN AN UPRIGHT (90 DEGREE/PERPENDICULAR) POSITION FOR 1 YEAR AFTER PLANTING IS COMPLETE OR UNTIL TREE ROOT SYSTEM IS FULLY ESTABLISHED AND STURDY.FINAL TREE STAKING DETAILS AND PLACEMENT TO BE APPROVED BY OWNER'S REPRESENTATIVE.2.CONTRACTOR SHALL ASSURE PERCOLATION OF ALL PLANTING PITS PRIOR TO INSTALLATION.3.IN SEMI-IMPERVIOUS SOIL CONDITIONS, ROOTBALL ELEVATION SHALL BE 2" ABOVE FINISH GRADE. COORDINATE WITH OWNER'SREPRESENTATIVE PRIOR TO SETTING ROOTBALL ELEVATIONS.
12" TYP.
12"MIN.
DOUBLE SIZE OFROOTBALL, TYP.
CLEAR TRUNK,REFER TO PLANTSCHEDULE
COMPACTED SUBGRADE
AMENDED PLANTING SOIL ASNEEDED PER SOIL ANALYSIS3" MINIMUM MULCH DEPTH,REFER TO PLANT SCHEDULE FORTYPEFINISH GRADESOIL BERM TO HOLD WATERMAINTAIN TREE IN A PLUMBUPRIGHT POSITION
TRUNK OF PALMETTOS SHALL BENEARLY UNIFORM IN SIZE OVERENTIRE HEIGHT AND SHALL BEFREE OF OLD FROND STUBS, FIREBLACK AND OTHER DAMAGE
REFOLIATED PALMETTO
NOTES:1.FINAL TREE STAKING DETAILS AND PLACEMENT TO BE APPROVED BY OWNER OR OWNER'S REPRESENTATIVE,2.CONTRACTOR SHALL ASSURE PERCOLATION OF ALL PLANTING PITS PRIOR TO INSTALLATION.3.SABAL PALMETTOS SHALL BE REFOLIATED, PROTECT CABBAGE HEAD FROM DAMAGE.
NOTES:1.WHEN GROUNDCOVERS AND SHRUBS ARE USED IS MASSES, ENTIRE BED TO BE EXCAVATED TO RECEIVE PLANTING SOIL ANDPLANT MATERIAL.2.CONTRACTOR SHALL ASSURE PERCOLATION OF ALL PLANTING PITS PRIOR TO INSTALLATION.3.IN SEMI-IMPERVIOUS SOIL CONDITIONS, ROOTBALL ELEVATION SHALL BE ±2" ABOVE FINISH GRADE. COORDINATE WITHOWNER'S REPRESENTATIVE PRIOR TO SETTING ROOTBALL ELEVATIONS.
4" TYP.DOUBLE SIZE OFROOTBALL, TYP.AMENDED PLANTING SOIL ASNEEDED PER SOIL ANALYSISB&B OR CONTAINERIZED (SEEPLANTING SCHEDULE, THIS SHEET)FINISH GRADESOIL BERM TO HOLD WATER3" MINIMUM MULCH DEPTH,REFER TO PLANT SCHEDULE FORTYPE
--- SPECIFIED O.C. SPACINGNOTE:1.EXCAVATE ENTIRE BED SPECIFIED FORGROUNDCOVER PLANTING TO A DEPTHOF 12"TYPICAL EDGE OFPLANT BED1/2 OF SPECIFIED O.C.SPACINGSPECIFIED O.C.SPACINGATYPICAL SPACING INCURVILINEAR PLANT BEDS.OUTSIDE ROW TO FOLLOWCURVE AS SHOWN ON PLAN
±5' DIA.3" MINIMUM MULCH DEPTH, REFERTO PLANT SCHEDULE FOR TYPESMOOTH CONTINUOUSLY CUT EDGETYPICAL TREETREE STAKE
NOTES:1.APPLY MULCH IN A ±5' DIAMETER WHEREPROPOSED TREE PLANTINGS OCCUR IN SODOR SEEDED AREAS.
CAT. I AND CAT. II TREE MITIGATION SATISFIED BY PLANTINGOF 4 LIVE OAKS (QUEV)SEE PLANT SCHEDULE -CAT. III MITIGATION SATISFIED BY PLANTING OF 13 ILEV, 3MAGV, AND 2 SABP.SEE PLANT SCHEDULE -NOTE:***
*******
Page 59 of 69
SITE DEVELOPMENT PLANSFORMEMORY MATTERSHILTON HEAD ISLAND, SOUTH CAROLINA
DRAWING NUMBERDRAWING TITLE
DESIGN CONCEPTS, DRAWING, SHEETS,LOGOS, SPECIFICATIONS, DETAILS,WRITTEN MATERIAL SHALL NOT BE USEDOR REPRODUCED IN WHOLE OR IN PARTIN ANY FORM WITHOUT PRIOR WRITTENCONSENT OF WJK LTD.© 2026 WJK LTD.THIS SHEET TO SCALE AT: 24"X36"
DATE:PROJECT NO.:DRAWN BY:CHECKED BY:JUL 29, 202626056.01SDJC
REVISIONS:DRB SUBMITTALPLAN, NOT FORCONSTRUCTION
L600SITE DETAILS - 01
1L600TREE PROTECTION FENCESCALE: 1" - 1'-0"2L600SILT FENCESCALE: 1" - 1'-0"
3L600BRICK PAVERSSCALE: 1" - 1'-0"4L600TABBY CONCRETESCALE: 1" - 1'-0"5L600GRANITE FINESSCALE: 1" - 1'-0"
6L600CONCRETE STAIRSSCALE: 1" - 1'-0"7L600GATESCALE: 3/4" - 1'-0"
SECTION4", TYP.1012" 3'-3"7"11"6'-8' O.C., FIELD ADJUSTTO PROTECT TREE412" SLOTS3'-10"2'6"
RADIUS = 12 X D.B.H. OR5', WHICHEVER IS GREATER3"X6" CEDAR SPLITRAIL UPRIGHTS,NATURAL FINISH2"X4" CEDAR SPLITRAILS WITHTAPERED TIPS TOMEET SLOTS,NATURAL FINISHCOMPACTEDAGGREGATE BASEEXISTING SUBGTADE
WARNING SIGN24"x24" MIN.TREE PROTECTION ZONEDOT NOT ENTERZONA DE PROTECCIONDE ARBOLESNO ENTRAR
ALTERNATIVE FENCING:BRIGHT ORANGE PLASTIC MESH - 48" HT. WITH REQUIRED SIGNAGE. PER TOWN OF HILTON HEAD LMO SEC. 16-6-104.3
MAXIMUM SPACING = 6 FT.FILTER FABRICBACKFILL TRENCH WITHCOMPACTED EARTHCOMPACTEDEARTHFILTER FABRIC6-IN.24-IN.(MINIMUM)
24-IN.(MINIMUM)6-IN.
RUNOFFRUNOFF
RUNOFF
18-IN. TO 24-IN.
BURY FABRICUSE EITHER FLAT-BOTTOMOR V-BOTTOM TRENCHSEE DETAILS
FLAT-BOTTOM TRENCH DETAIL
V-SHAPED TRENCH DETAIL
SILT FENCE INSTALLATION
FILTERFABRIC
BURY FILTER FABRICAT LEAST 12-INCHES
1.25 LB./LINEAR FT. STEEL POSTSHEAVY DUTYPLASTIC TIEFOR STEEL POSTS(RESTRICT TO TOP8-INCHES OFFABRIC)18-IN. TO 24-IN.SILT FENCE - GENERAL NOTES1.Do not place silt fence across channels or in other areas subject to concentrated flows. Silt fenceshould not be used as a velocity control BMP. Concentrated flows are any flows greater than 0.5 cfs.2.Maximum sheet or overland flow path length to the silt fence shall be 100-feet.3.Maximum slope steepness (normal [perpendicular] to the fence line) shall be 2:1.4. Silt fence joints, when necessary, shall be completed by one of the following options:-Wrap each fabric together at a support post with both ends fastened to the post, with a 1-foot minimum overlap;-Overlap silt fence by installing 3-feet passed the support post to which the new silt fence roll is attached. Attach old roll to new roll with heavy-duty plastic ties; or,-Overlap entire width of each silt fence roll from one support post to the next support post.5. Attach filter fabric to the steel posts using heavy-duty plastic ties that are evenly spaced within thetop 8-inches of the fabric.6.Install the silt fence perpendicular to the direction of the stormwater flow and place the silt fencethe proper distance from the toe of steep slopes to provide sediment storage and access formaintenance and cleanout.7.Install Silt Fence Checks (Tie-Backs) every 50-100 feet, dependent on slope, along silt fence that isinstalled with slope and where concentrated flows are expected or are documented along theproposed/installed silt fence.
HEAVY DUTY PLASTIC TIESSILT FENCE - POST REQUIREMENTS1.Silt Fence posts must be 48-inch long steel posts that meet, at a minimum, thefollowing physical characteristics.-Composed of a high strength steel with a minimum yield strength of 50,000 psi.-Include a standard "T" section with a nominal face width of 1.38-inches and anominal "T" length of 1.48-inches.-Weigh 1.25 pounds per foot (± 8%)2.Posts shall be equipped with projections to aid in fastening of filter fabric.3. Steel posts may need to have a metal soil stabilization plate welded near thebottom when installed along steep slopes or installed in loose soils. The plate shouldhave a minimum cross section of 17-square inches and be composed of 15 gaugesteel, at a minimum. The metal soil stabilization plate should be completely buried.4.Install posts to a minimum of 24-inches. A minimum height of 1- to 2- inchesabove the fabric shall be maintained, and a maximum height of 3 feet shall bemaintained above the ground.5.Post spacing shall be at a maximum of 6-feet on center.SILT FENCE - FABRIC REQUIREMENTS1.Silt fence must be composed of woven geotextile filter fabric that consists ofthe following requirements:-Composed of fibers consisting of long chain synthetic polymers of at least 85% byweight of polyolefins, polyesters, or polyamides that are formed into a networksuch that the filaments or yarns retain dimensional stability relative to each other;-Free of any treatment or coating which might adversely alter its physicalproperties after installation;-Free of any defects or flaws that significantly affect its physical and/or filteringproperties; and,-Have a minimum width of 36-inches.2.Use only fabric appearing on SC DOT's Qualified Products Listing (QPL),Approval Sheet #34, meeting the requirements of the most current edition of theSC DOT Standard Specifications for Highway Construction.3. 12-inches of the fabric should be placed within excavated trench and toed inwhen the trench is backfilled.4.Filter Fabric shall be purchased in continuous rolls and cut to the length ofthe barrier to avoid joints.5.Filter Fabric shall be installed at a minimum of 24-inches above the ground.
1.The key to functional silt fence is weekly inspections, routine maintenance, andregular sediment removal.2.Regular inspections of silt fence shall be conducted once every calendar weekand, as recommended, within 24-hours after each rainfall even that produces1/2-inch or more of precipitation.3.Attention to sediment accumulations along the silt fence is extremely important.Accumulated sediment should be continually monitored and removed whennecessary.4.Remove accumulated sediment when it reaches 1/3 the height of the siltfence.5. Removed sediment shall be placed in stockpile storage areas or spread thinlyacross disturbed area. Stabilize the removed sediment after it is relocated.6.Check for areas where stormwater runoff has eroded a channel beneath thesilt fence, or where the fence has sagged or collapsed due to runoffovertopping the silt fence. Install checks/tie-backs and/or reinstall silt fence,as necessary.7.Check for tears within the silt fence, areas where silt fence has begun todecompose, and for any other circumstance that may render the silt fenceineffective. Removed damaged silt fence and reinstall new silt fenceimmediately.8.Silt fence should be removed within 30 days after final stabilization is achievedand once it is removed, the resulting disturbed area shall be permanentlystabilized.
SILT FENCE - INSPECTION & MAINTENANCE
COMPACTEDEARTHFILTER FABRICHEAVY DUTY PLASTIC TIES6-IN.
HAND TIGHT / BUTTJOINTED WITH SANDSWEPT JOINTSNOTES:1.PROVIDE 1% MIN., 2% MAX. CROSS SLOPEON ALL PAVED SURFACES FOR POSITIVEDRAINAGE.2.REFER TO PLAN (SHEET L200) FORWIDTHS OF WALKS AND LOCATION OFBRICK BORDERS.3.CONTRACTOR SHALL COORDINATEBORDERS AND PATTERN WITH OWNER'SREPRESENTATIVE PRIOR TOCONSTRUCTION.4.UPON REQUEST, CONTRACTOR SHALLPROVIDE 4'X4' PAVING PANELS OFALTERNATIVE COLORS PRIOR TOCONSTRUCTION FOR APPROVAL BYOWNER OR LANDSCAPE ARCHITECT.
BRICK MANUFACTURER INFORMATION:MANUFACTURER: TO MATCHARCHITECTUREBRICK: TO MATCH ARCHITECTURECOLOR: TO MATCH ARCHITECTUREPATTERN: HERRINGBONE FIELD (REFERTO PLAN, SHEET L100, FOR DIRECTION)WITH SINGLE HEADER COURSE BORDERJOINTS: HAND TIGHT / BUTT JOINTED,SAND SWEPT
4"5"8" BRICK FIELD, TYP.BRICK BORDER, TYP.SAND SETTING BED PERMANUFACTURER'SSPECIFICATIONSCONCRETE BASECOMPACTEDAGGREGATE BASE COMPACTED SUBGRADEEXISTING SUBGRADE6" MORTAR, TYP.
BRICK FIELD, TYP.BRICK BORDER, TYP.HAND TIGHT / BUTTJOINTED WITH SANDSWEPT JOINTS45° CUT ATINTERSECTIONS, TYP., CUTALL BRICK FROM FULL,TYP.ADJACENT MATERIALVARIES, REFER TO PLANSPLAN
SECTION A-A'
AA'OTHER INFORMATION:CONCRETE: 3,000 P.S.I. AT 28 DAYSSOIL COMPACTION: 95% STANDARDPROCTORFINISHED GRADE4"6"NOTES:1.PROVIDE 1% MIN., 2% MAX. CROSS SLOPEON ALL PAVED SURFACES FOR POSITIVEDRAINAGE.2.REFER TO PLAN (SHEET L200) FORWIDTHS OF WALK.3.CONSTRUCT EXPANSION JOINTS WHEREWALK MEETS CURBS, STEPS, WALLS ORFIXED SLABS.4.UPON REQUEST, CONTRACTOR SHALLPROVIDE 4'X4' SAMPLE OF CONCRETEWITH 2 SIZES OF OYSTER SHELL FINISHFOR APPROVAL BY OWNER ORLANDSCAPE ARCHITECT.
TABBY SPEC:1.SHELL FINISH SHALL BE OYSTER SHELL MIX(EQUAL PARTS, SIZE #2, AND #3) HANDTHROWN / SPREAD TO 100% COVERAGEON FRESH POURED AND LEVELEDCONCRETE.2.HAND FLOAT UNTIL SHELL ISSUBMERGED, THEN AFTER 90% CURED,LIGHTLY PRESSURE WASH UNTIL SHELL ISEXPOSED.
SECTION A-A'12"TABBY CONCRETE WALKWITH TURNDOWNSAND 6X6 10-10 W.W.M.FINISHED GRADECOMPACTEDSUBGRADEEXISTING SUBGRADEBRICK BORDER, TYP.MORTAR SETTING BEDPER MANUFACTURERSSPEC., TYP.
BRICK MANUFACTURER INFORMATION:MANUFACTURER: TO MATCHARCHITECTUREBRICK: TO MATCH ARCHITECTURECOLOR: TO MATCH ARCHITECTUREPATTERN: SINGLE HEADER COURSE BORDERJOINTS: TO MATCH ARCHITECTUREPLAN
TABBY CONCRETEWALKEXPANSION JOINTCONTROL JOINTA
A'WIDTH VARIES, REFER TOPLAN, SHEET L200
BRICK BORDER, TYP.MORTAR JOINTS, TYP.
CONCRETE INFORMATION:CONCRETE: 3,000 P.S.I. AT 28 DAYSFINISH: TABBY SHELL
SOIL INFORMATION:SOIL COMPACTION: 95% STANDARDPROCTOR4"
45° CUT ATINTERSECTIONS, TYP., CUTALL BRICK FROM FULL,TYP.± 5"PLANSECTION A-A'
STEEL STAKEFINISHEDGRADE± 4" COMPACTED CRUSHEDAGGREGATE BASEGEOTEXTILE FABRIC± 1" SPRING MIX GRAVEL TOPCOATCOMPACTED SUBGRADEEXISTING SUBGRADE
SPRING MIX GRAVELADJACENT MATERIALVARIES, REFER TO PLANS(SHEET L200)STEEL EDGINGAA'EDGING AND STAKE INFORMATION:MANUFACTURER:BORDER CONCEPTS, INC.7621 LITTLE AVE., SUITE 426CHARLOTTE, NC. 28226PHONE: (800) 845.3343WEB: WWW.BORDER CONCEPTS.COMSTEEL EDGE: BORDER GUARD 3/16" X 4" X 16'STAKES: :STANDARD STAKE 3/16" THICK X 15"LONG (6 PER 16')COLOR: BLACKNOTE: INSTALL FLUSH PER MANUFACTURESSPECIFICATIONSOTHER INFORMATION:GEOTEXTILE FABRIC: TYPAR 3401 ORAPPROVED EQUALSOIL COMPACTION: 95% STANDARDPROCTOR4"STEEL EDGING
4" NON-SLIP SKIDGUARDS AS REQUIRED1'-2"7"R12" 10"12"
EXPANSION JOINT, TYP.
COMPACTEDAGGREGATE BASECOMPACTEDSUBGRADEEXISTING SUBGRADE
CONCRETE STEPS ANDFOOTING, TYP.
"L" BAR IN NOSE,CONTINUOUS, TYP."H" BAR, TYP."V" BAR, NO SPLICESHALL BE MADE, TYP.12" LONG METALDOWEL, TYP."L" BAR,CONTINUOUS, TYP.
TABBYCONCRETEWALK, REFERTO DETAILX/LXEXPANSIONJOINT, TYP.REFER TODETAIL X/LXTABBY CONCRETE WALK,REFER TO DETAIL 4/L600NOTES:1.PROVIDE MIN. 1%, MAX. 2%CROSS SLOPE ON ALL PAVEDSURFACES FOR POSITIVEDRAINAGE.2.REFER TO PLAN FOR WIDTHS OFWALK.3.CONSTRUCT EXPANSION JOINTSWHERE WALK MEETS CURBS,STEPS, WALLS OR FIXED SLABS.4.UPON REQUEST, CONTRACTORSHALL PROVIDE 4'X4' SAMPLE OFCONCRETE WITH 2 SIZES OFOYSTER SHELL FINISH FORAPPROVAL BY OWNER ORLANDSCAPE ARCHITECT.
CONCRETE INFORMATION:CONCRETE: 3,000 P.S.I. AT 28 DAYSFINISH: LIGHT BROOM FINISH WITHGRIT SEALER (STEPS TO HAVE NONSLIP SURFACE)SOIL INFORMATION:SOIL COMPACTION: 95% STANDARDPROCTORREBAR SCHEDULEREBARSIZESPACING"H" BAR"V" BAR#4#412" O.C.12" O.C.6"4""L" BAR#412" O.C.METALDOWEL#424" O.C.
TYP. SECTION A-ANOTES:1.FENCE / GATE POSTS MOUNTING TO BECONFIRMED PER MANUFACTURERS SPEC. TO POOLDECK AND CONCRETE WALK. REFER TO PLANSHEET L200 FOR LOCATION.2.INSTALLATION TO BE COMPLETED PERMANUFACTURERS SPECIFICATIONS.3.CONTRACTOR SHALL CONFIRM GATE OPENINGAND HINGE ATTACHMENTS TO WOOD POSTSPRIOR TO CONSTRUCTION. REPORT ANYDISCREPANCIES TO OWNER , OWNER'SREPRESENTATIVE OF LANDSCAPE ARCHITECT.4.CONTRACTOR SHALL PROVIDE COLOR SAMPLESPRIOR TO CONSTRUCTION FOR APPROVAL BYOWNER OR LANDSCAPE ARCHITECT.
LATCH, HINGE AND CANE BOLT INFORMATION:LATCH:SELF-LOCKING / QUICK RELEASEOR ACCESSED CONTROLLEDHINGE: SELF-CLOSINGCANE BOLT: TO BE COORDINATED WITHACCESS CONTROLLED LATCHOWNER TO APPROVE LATCH AND HINGEATTACHMENTS PRIOR TO ORDERING.FINISHED GRADE
6X6 WOOD POST1" SQUARE ALUMINUMFRAME, TYP.1" SQUAREALUMINUM RAIL, TYP.HINGE, TYP.FENCE5/8" SQUAREALUMINUM PICKET,TYP.4'-4"4'MIN.REFER TO NOTE 1FOR ATTACHMENTFINISHED GRADEALUMINUM GATE,REFER TO ELEVATIONAND MANUFACTURERSINFORMATION6X6 WOOD POST,SEE DETAIL 1/L602
72" WIDTH ELEVATIONA
A
LATCH, TYP.6X6 WOOD POST, TYP.CANE BOLT, REFER TO ELEVATION
4'MIN.4'-4"6'2'-1012"112"
3"
6'-5" O.C.72" WIDTH PLANINTERIOR SIDEEXTERIOR SIDEALUMINUM GATE
CANE BOLT, TYP.
SELF-LATCHINGLATCH, TYP.HINGE, TYP.312" MAX.
GATE MANUFACTURER INFORMATION:MANUFACTURER:JERITH MANUFACTURING LLC14400 MCNULTY RD,PHILADELPHIA, PA, 19154PHONE: (800) 344.2242WEB: WWW.JERITH.COMGATE: LIBERTY STANDARD GATE 202 - 48"HEIGHTMATERIAL: ALUMINUMFENCE:POWDER COATED BLACKPOSTS:6X6 PRESSURE TREATED PINEMATERIAL: WOODCOLOR:MATCH STUCCO ACCENT OFBUILIDNG
Page 60 of 69
SITE DEVELOPMENT PLANSFORMEMORY MATTERSHILTON HEAD ISLAND, SOUTH CAROLINA
DRAWING NUMBERDRAWING TITLE
DESIGN CONCEPTS, DRAWING, SHEETS,LOGOS, SPECIFICATIONS, DETAILS,WRITTEN MATERIAL SHALL NOT BE USEDOR REPRODUCED IN WHOLE OR IN PARTIN ANY FORM WITHOUT PRIOR WRITTENCONSENT OF WJK LTD.© 2026 WJK LTD.THIS SHEET TO SCALE AT: 24"X36"
DATE:PROJECT NO.:DRAWN BY:CHECKED BY:JUL 29, 202626056.01SDJC
REVISIONS:DRB SUBMITTALPLAN, NOT FORCONSTRUCTION
L601SITE DETAILS - 02
1L601FENCESCALE: 3/4" - 1'-0"2L601ARBORSCALE: 1/2" - 1'-0"
FENCE MANUFACTURER INFORMATION:MANUFACTURER:JERITH MANUFACTURING LLC14400 MCNULTY RD,PHILADELPHIA, PA, 19154PHONE: (800) 344.2242WEB: WWW.JERITH.COMFENCE: RESIDENTIAL FENCE STYLE 202 - 48" HEIGHTMATERIAL: ALUMINUMCOLOR: POWDER COATED BLACKPOSTS: 4X4 PRESSURE TREATED PINEMATERIAL: WOODCOLOR: MATCH STUCCO ACCENT OF BUILDING
NOTES:1.INSTALLATION TO BE COMPLETEDPER MANUFACTURERSSPECIFICATIONS2.CONTRACTOR TO VERIFY ALLDIMENSIONS PRIOR TOCONSTRUCTION. REPORT ANYDISCREPANCIES TO OWNER,OWNER'S REPRESENTATIVE ORLANDSCAPE ARCHITECT.3.CONTRACTOR SHALL PROVIDECOLOR SAMPLES PRIOR TOCONSTRUCTION FOR APPROVAL BYOWNER OR LANDSCAPE ARCHITECT.SECTION - A
612"2'-11"7"112" ± 5'-11"
2" MIN.
4'-4"4" MAX., TYP.
FINISHEDGRADE
1" TAPER CAP4x4 WOOD POST,6X6 POST ATCORNERS ANDGATES1" SQUAREALUMINUM RAIL,TYP.5/8" SQUAREPICKET, TYP.
1'-11"4"4"TYP.
4'-4"4' A
A
1112" ELEVATIONSET TOP OFCONCRETE 1" BELOWFINISHED GRADE,SLOPE TO DRAINCOMPACTEDSUBGRADEEXISTING SUBGRADEFINISHED GRADEALUMINUM FENCE,REFER TO ELEVATIONAND MANUFACTURERSINFORMATIONCONCRETE FOOTING
4X4 WOOD POST,6X6 POST ATCORNERS ANDGATES
OTHER INFORMATION:CONCRETE: 3,000 P.S.I. AT 28 DAYSSOIL COMPACTION: 95% STANDARD PROCTOR
8'4'-6"3'-112" 5'R2'-6"
SIDE ELEVATION DIAGRAMFRONT ELEVATION(FOR DETAILED INFORMATIONREFER TO FRONT ELEVATIONTHIS DETAIL)
R2'-6"
3"
CUT WOOD ARCHFROM 6" X MATERIAL(OVERLAP LAPJOINTS 4" MIN.6"X6" WOOD ARCH2"X2" WOOD PERLINWRAP 6"X6" WOODPOST WITH 1"X4"WOOD TRIM 1/2"CHAMFER AT TOPAND BOTTOM, TYP.4"X6" WOOD POST
WOOD FENCEMETAL HINGE,BLACK, BY OWNERSELF LATCHINGGATE MECHANISM,BLACK (MOUNT ONINTERIOR OF FENCE1"X4" WOODBOARDS, TYP.1"X4" WOOD FRAME,TYP.FINISHED GRADE5'-6" O.C.TABBY CONCRETEWALK
4" O.H.TYP.WOODPERLINWOODPOST
NOTES:1.ALL LUMBER SHALL BE PRESSURE TREATED SOUTHER YELLOW PINE, COLOR TO MATCHSTUCCO ACCENT OR TO BE APPROVED BY OWNER.2.ALL CONNECTORS SHALL BE STAINLESS STEEL. ATTACHMENTS SHALL BE WITH STAINLESSSTEEL SCREWS SUITABLE FOR PRESSURE TREATED WOOD, NO NAILS SHALL BE USED.3.CONTRACTOR SHALL PROVIDE COLOR SAMPLES TO BE APPROVED BY OWNER'SREPRESENTATIVE.
WOOD FENCEIN FRONTGATE BEYOND,REFER TOLAYOUT PLAN(SHEET L200)FOR GATELOCATION
3L601PATH LIGHTSCALE: NTS4L601UPLIGHTSCALE: NTS5L601STEP LIGHTSCALE: NTS
OR EQUAL - SUBSTITUTIONS TOBE APPROVED BY OWNERS REP.OR EQUAL - SUBSTITUTIONS TOBE APPROVED BY OWNERS REP.OR EQUAL - SUBSTITUTIONS TOBE APPROVED BY OWNERS REP.
Page 61 of 69
SITE DEVELOPMENT PLANSFORMEMORY MATTERSHILTON HEAD ISLAND, SOUTH CAROLINA
DRAWING NUMBERDRAWING TITLE
DESIGN CONCEPTS, DRAWING, SHEETS,LOGOS, SPECIFICATIONS, DETAILS,WRITTEN MATERIAL SHALL NOT BE USEDOR REPRODUCED IN WHOLE OR IN PARTIN ANY FORM WITHOUT PRIOR WRITTENCONSENT OF WJK LTD.© 2026 WJK LTD.THIS SHEET TO SCALE AT: 24"X36"
DATE:PROJECT NO.:DRAWN BY:CHECKED BY:JUL 29, 202626056.01SDJC
REVISIONS:DRB SUBMITTALPLAN, NOT FORCONSTRUCTION
L602SITE DETAILS - 03
1L602WALL LIGHTSCALE: NTSOR EQUAL - SUBSTITUTIONS TOBE APPROVED BY OWNERS REP.
2L602SITE FURNISHINGSSCALE: NTS
MANUFACTURER INFORMATION:LANDSCAPEFORMSKALAMAZOO, MI 29048PHONE: (800) 430.6209WEB: WWW.LANDSCAPEFORMS.COMMODEL: BASICCOLOR: FOGOTHER INFO: 23" BENCH WITH BACKAND ARMS; 60" FOUR SLAT TABLEOR APPROVED EQUAL
TABLE AND CHAIRSBENCHGARDEN PLANTERS
MANUFACTURER INFORMATION:LANDSCAPEFORMSKALAMAZOO, MI 29048PHONE: (800) 430.6209WEB: WWW.LANDSCAPEFORMS.COMMODEL: MELVILLE BENCHCOLOR: FOGOTHER INFO: 76" BACKED BENCHOR APPROVED EQUAL
MANUFACTURER INFORMATION:VEGTRUGHATFIELD, PA 19440PHONE: (888) 908.2008WEB: WWW.US.VEGTRUG.COMMODEL: VEGTRUG CLASSIC 1.8MCOLOR: NATURALOR APPROVED EQUAL
MANUFACTURER INFORMATION:EARTHEASYPHONE: (888) 451.6752WEB: WWW.EARTHEASY.COMMODEL: HARMONY ACCESSIBILITYSELF-WATERING CEDAR GARDENCOLOR: RAW CEDAROR APPROVED EQUAL
Page 62 of 69
MEMORY MATTERS RENOV AION
15 TRELLIS COURT
EXTERIOR COLORS &
EXTERIOR LIGHT DETAILS
Page 63 of 69
MEMORY MATTERS EXTERIOR COLORS
As the Eurostone building is remodeled into the new home of Memory Matters, it is the intention
that the materials on the exterior of the Four Season Room addition mimic the existing exterior
colors.
Therefore the metal roof and the window frames will be sage green, and the flyash horizontal
siding will match the main beige stucco color. The flyash trim will be the same color as the
existing stucco trim. New concrete walks will match existing concrete walks. Minor alterations
to the paver parking lot will match the existing pavers.
Page 64 of 69
,.,.SAVOY HOUSE
A LIGHTING NEW YORK STORE
Q Find the products you'll love My Projects O e,,
Lighting Fans Furniture & Decor Sale & Clearance Shop Collections Shop by Room
o @ [si .G o ts·, - iii ii
Savoy House I Lighting I Outdoor Lighting I Outdoor Wall Lights
Er Stella Outdoor Flood Light in Bronze, Essentials
by Savoy House
SKU: 4-FLOOD-A2-3000K-BZ
ix;;;; 0Reviews
$37.40 s+4.00
Select Finish: Bronze
15% 0ffapplied. Details
$37.40 s44.0o too+in stock)
V Add to Cart Free Returns! Details
9 No Restocking Fee Q Bulbs Included
Are you a Trade Professional?
Log in to your LNY Pro account, or sign up
here to receive exclusive trade pricing and
other Pro benefits today!
Original List Price: $67.00 (you save 34.39%)
In stock items ship in 1-2 business days.
CO Add to Project
f
Love the look of this product?
Ex6 lore Similar St vies
Recommended by LNY, Powered by Beacon
6' Request Price Alert
Page 65 of 69
#SAVOY HOUSE
A LIGHTING NEW YORK STORE
Q Find the products you'll love My Projects O e,,
Lighting Fans Furniture & Decor Sale & Clearance Shop Collections Shop by Room
pt Stella Outdoor Flood Light in Bronze, Essentials
Product Specifications
EER
Product Information
Brand: Savoy House
Brand Category: Outdoor Flood Light
Brand Product Description: LED Double Flood Light in Bronze
Shipping Method: Ground
SKU: 4-FLOOD-A2-3000K-BZ
UPC:822920311383
Electrical and Operational Information
Color Rendering Index: 80
Color Temperature: 3000K
Dimmable: No
Lamping Category: LED
Lamping Features: LED Delivered Lumens: 1600
Lamping Included: Bulbs Included
Lamping Type: Integrated LED
Lumens: 1600
Primary Number of Bulbs: 2
Socket: Integrated LED
Total Number of Bulbs: 2
Voltage: 120V
Wattage Max: 22.00
Dimensions and Measurements
Backplate/Canopy Extension: 1.77
Backplate/Canopy Height: 5
Backplate/Canopy Width: 5
Height: 4.13
Weight: 1.56
Width:7.87
Warranty and Specifications
Prop 65: Yes
UL Ratings: ETL Wet
Additional Details
Features:
• Maximum Extends: 6.5
• Assembly Required: Minimal Required
• Maximum Extends: 6.5
• Minimal Assembly Required
Material: Aluminum/ Glass
Page 66 of 69
972-535-0926 | PLTSOLUTIONS.COM | ver 021723
WATTAGE AND COLOR SELECTABLE LED CANOPY FIXTURE
FEATURES
WARRANTY
LISTINGS
THERMAL
INSTALLATION
ELECTRICAL
CONSTRUCTION
PERFORMANCE
DESCRIPTION
project name type
catalog number
comments voltage
approved by date
• Up to 157 LPW ultra-high efficiency delivers superior
performance over older fixtures
• Replaces 50W, 150W, or 250W metal halide fixtures
• Lumen output varies depending on the wattage and color
temperature selected; see Selectable Table for full breakdown
• Wattage and color temperature are adjusted via dip switches
on the side of the fixture underneath clear plastic knockouts;
see installation instructions for more information
• 0-10V dimming; see Compatible Dimmers section for full list of
compatible dimmers
• 5 year limited warranty; see
pltsolutions.com for warranty details
• IP65 Rated
• UL Listed for wet locations
• IK10
• DesignLights Consortium® 5.1 Premium - meets the
requirements for the highest DLC qualification for efficacy and
lumen maintenance
• -22°F to 113°F (-30°C to 45°C) operating temperature
• Designed for pendant or surface mounting with J-box (not
included); see installation instructions for more information
• THD: ≤20%
• Power Factor: ≥0.9
• Input Voltage: 120-277V
• Dimmable power supply (0-10V)
• Surge Protection: 4kV
• Low-profile aluminum alloy housing with white finish
• PC lens
• CRI: >80
• CCT: 3000K, 4000K, 5000K
• LED L70 Life Hours: 160,000 hours
• BUG: B1-U3-G1, B1-U3-G2, or B1-U3-G3
A long-lasting and highly efficient replacement for metal halide
fixtures, use this wattage and color selectable LED canopy light to
improve outdoor security lighting.
APPLICATIONS
• Warehouses
• Factories
• Hospitals
• Hotels
• Offices
1
Page 67 of 69
972-535-0926 | PLTSOLUTIONS.COM | ver 021723
Item # Watts* CCT CRI Lens Dimming Voltage Replaces BUG DLC # DLC Level
PLT-12486
10/
15/
20
3000K/
4000K/
5000K
>80 PC 0-10V 120-277V MH50 B1-U3-G1 PLTSNM111141 5.1 Premium
PLT-12487
20/
30/
40
3000K/
4000K/
5000K
>80 PC 0-10V 120-277V MH150 B1-U3-G2 PLTSNM211141 5.1 Premium
PLT-12488
40/
60/
70
3000K/
4000K/
5000K
>80 PC 0-10V 120-277V MH250 B1-U3-G3 PLTSNM311141 5.1 Premium
2
PERFORMANCE SUMMARY
SELECTABLE TABLE
COMPATIBLE DIMMERS
* See Selectable Table for full breakdown
Item # Wattage CCT Lumen Efficacy
PLT-12486
10
3000K 1328 133
4000K 1400 140
5000K 1393 139
15
3000K 1899 127
4000K 2031 135
5000K 2060 137
20
3000K 2656 133
4000K 2860 143
5000K 2892 145
PLT-12487
20
3000K 2767 138
4000K 2984 149
5000K 3032 152
30
3000K 4038 135
4000K 4394 146
5000K 4398 147
40
3000K 5010 125
4000K 5399 135
5000K 5462 137
PLT-12488
40
3000K 5696 142
4000K 6188 155
5000K 6283 157
60
3000K 7743 129
4000K 8710 145
5000K 8695 145
75
3000K 9363 125
4000K 9812 131
5000K 9977 133
Brand Model
Legrand RH4FBL3PTC
Leviton IP710-DLZ
Leviton DS710-10Z
Lutron NTSTV-DV-WH
Lutron NFTV-WH
Lutron DVSTV-WH
Page 68 of 69
972-535-0926 | PLTSOLUTIONS.COM | ver 021723
3
DIMENSIONS
PHOTOMETRICS
PL T-12486
DIMENSIONS:
PL T-12486
PHOTOMETRICS:
PL T-12487
DIMENSIONS
PL T-12487
PHOTOMETRICS:
PL T-12488
DIMENSIONS:
PL T-12488
PHOTOMETRICS:
Length: 8.03"
Height: 3.5"
Width: 8.03"
Weight: 2.98 lbs
Length: 8.03"
Height: 3.5"
Width: 8.03"
Weight: 3.9 lb
Length: 10"
Height: 3.9"
Width: 10"
Weight: 6.26 lbs
8.03" 8.03"
3.5" 3.5" 3.9"
8.03" 8.03"
10"
10"
Page 69 of 69
Source: Town of Hilton Head Island website. First collected Oct 13, 2026.