RecordWell Data

Agenda

City of Isle of Palms · Charleston County · meeting of Sep 1, 2026 · Agenda packets

Open the original document More from City of Isle of Palms

This document is no longer listed on City of Isle of Palms's website. We kept the copy we read.

Text

Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.

P ublic Services & Facilities Committee 9:00 a.m., Tuesday, September 1, 2026 1207 Palm Boulevard City Hall Council Chambers P ublic Comment: Citizens who wish to speak during the meeting must email their first and last name, address and topic to Nicole DeNeane, City Clerk, at nicoled@isleofpalms.gov no later than 3:00 p.m. the day before the meeting. Citizens may also provide written public comment here: https://www.isleofpalms.gov/public-comment-form A genda 1. Call to order and acknowledgment that the press and the public have been dul y notified of the meeting in accordance with the Freedom of Information Act. 2. Citizens’ Comments – All comments have a time limit of three (3) minutes. 3. Approval of previous meeting’s minutes – August 4, 2026 4. Marina Tenants’ Comments 5. Departmental Reports- P ublic Works overview from Director Asero 6. Old Business a. U pdate and discussion of Waterway Boulevard project b. Update and discussion of beach projects c. Update and discussion of marina parking lot reconfiguration d. Update and discussion of marina dredging project work schedule e. Discussion and consideration of amending trash collection policies as they relate to commercial operations 7. N ew Business a. Discussion and consideration of proposals to manage bulkhead recoating b. Discussion and consideration of Waterway flood barrier project- Thomas and Hutton CO#6 $35,000 for additional field management expenses c. Discussion of Waterway flood barrier project- Thomas and Hutton CO#7 $63,550 for feasibility/planning work for Phase 3 of Waterway flood barrier project d. Discussion of drainage project for Palm Boulevard and 38th-41st Avenues e. Discussion and consideration of A/V RFP responses f. Discussion and consideration of IT RFP responses g. Consideration of purchase of new truck for Building Department for $37,686.00- Santee Automotive, State purchasing contract ($45,000 in FY27 budget, Capital) 8. M iscellaneous Business- next meeting: Tuesday, October 6, 2026 at 9am 9. A djournment 1 Public Services & Facilities Committee Meeting 9:00am, Tuesday, August 4, 2026 1207 Palm Boulevard, Isle of Palms, SC and broadcasted live on YouTube: https://www.youtube.com/user/cityofisleofpalms MINUTES 1. Call to Order Present: Council members Miars , Streetman and Pierce Staff Present: Deputy Administrator Kuester, Director Asero, Director Ferrell Absent: Administrator Kerr 2. Citizen’s Comments - none 3. Approval of Previous Meeting’s Minutes – July 7, 2026 MOTION: Council Member Streetman made a motion to approve the minutes. Council Member Pierce seconded the motion. The motion passed unanimously. 4. Marina Tenant’s Comments – none 5. Departmental Reports Council Member Pierce asked that future communications further clarify the dropoff spots for camp attendees. Council Member Pierce asked about the increased level of debris pickup. Director Asero agreed the volume was high for June and it has continued into July. He noted that construction and yard debris pickup has increased and that household waste has remained steady. Director Asero will share a “State of the Union” for the Public Works Department at the September meeting. 6. Old Business A. Update and discussion of Waterway Boulevard project Deputy Administrator Kuester reported that paving work continues. Some new infrastructure needs to be installed at 31st Avenue requiring AT&T to move some utilities which requires a permit from SCDOT. There is no timeline for when that permit might be received. Staff still anticipates a mid-September completion. 2 Public Services & Facilities Committee, 8/4/2026 2 Council Member Miars asked about the addition of a crosswalk at 28th Avenue connecting the Recreation Center to the Waterway Boulevard path. Deputy Administrator Kuester said he would look into it. B. Update and discussion of beach projects Deputy Administrator Kuester reported that renourishment began on July 27, and to date, Marinex has placed 157,000 cubic yards of sand within Wild Dunes. Dredge operations have stopped during the recent rainy weather. The project remains generally on schedule. Staff is working with BCM and DES to address some derelict sand fencing that is out of compliance with BCM standards. Deputy Administrator Kuester stated that at a point in the near future, the public will be unable to walk back and forth along the beach. The public has been notified of the lack of access. He believes that will last for a month. He added that sandbag removal will exacerbate the situation. He will work with Mr. Traynum on possible solutions and timeline. C. Update and discussion of marina parking lot reconfiguration Deputy Administrator Kuester reported that Mr. Cline has submitted permitting plans to the County for the marina parking lot. Permitting could take 6-9 weeks. He noted the differences between the concept plans and the permitting plans, including an update to the driveway between the trailer spots to allow for easier truck exit and maneuverability, an added bid alternate for a Barracuda water quality control system, a second bid alternate for a ribbon curve, and modified asphalt to match the existing conditions more closely. As water quality is an issue related to the permitting, the $50,000 water quality system will need more discussion when the bids are opened. Deputy Administrator Kuester said they are working closely with Mr. Cline to stay on top of the timeline due to the “kill switch” in the lease agreement. Updated timelines and planning documents will be available at the September meeting. D. Update on Marina dredging project work schedule Deputy Administrator Kuester stated that Geosyntech (formerly ATM) has prepared the plans for bidding. They are awaiting a package from USACE stating the City’s use of the disposal site near the IOP Connector creates no environmental impact on the ICW. The bid process can be initiated before that package arrives, but it is required prior to the start of work. E. Update on potential beach volleyball court Deputy Administrator Kuester said that while staff continues to investigate possible locations for a beach volleyball court, it will be hard to do without taking away from pre-existing programs. Director Ferrell said that a grass court could be a temporary solution that would allow them to gauge interest in the court. She estimates the cost of a grass court could be $3-$5,000. She will bring more information to the September meeting. 3 Public Services & Facilities Committee, 8/4/2026 3 F. Update on IT Costs Deputy Administrator Kuester said “big ticket” IT accounts are being pruned. The bid for managed IT services has gone out and there have been several site visits from potential vendors. The bids will be opened on August 28. G. Discussion of amending trash collection policies as they relate to commercial operations Director Asero said the City needs an ordinance to deal with “imported” debris. He noted that Wild Dunes has a rule preventing landscapers from leaving debris, but they have no way to enforce it. A cleaner version of the proposed ordinance will be discussed at the September meeting. 7. New Business A. Discussion and consideration of purchase of Public Works Automated Side Loader (FY 27, Hospitality Fund, $435K budgeted) Director Asero said this side loader is in the F27 budget and will provide departmental efficiencies, including savings on temporary labor, but add some maintenance. The truck will be received in the off season, giving staff time to be educated on its use as well as to educate residents on the proper placement of their roll carts. MOTION: Council Member Pierce made a motion to approve the purchase and recommend the purchase to the Ways & Means Committee for approval. Council Member Miars seconded the motion. The motion passed unanimously. B. Discussion of trash at the marina Committee members discussed the problem of trash at the marina following complaints from residents. Director Asero reviewed the trash pickup schedule at the marina, adding that some of the trash has been due to lack of oversight. He said household trash is being placed in the dumpsters. He would like an enclosed trash receptacle when the parking lot and greenspace are complete to prevent people from placing their trash in the area. Council Member Streetman reported that Mr. Lorenz has committed to trash sweeps of the area. Deputy Administrator Kuester said he will identify where the dumpsters will be located in the marina parking lot following the parking lot reconfiguration. 8. Miscellaneous Business The next regular meeting of the Public Services & Facilities Committee will be Tuesday, September 1, 2026 at 9am. 4 Public Services & Facilities Committee, 8/4/2026 4 9. Adjournment Council Member Pierce made a motion to adjourn and Council Member Streetman seconded the motion. The meeting was adjourned at 10:19am. Respectfully submitted, Nicole DeNeane City Clerk 5 Month 2021 2022 2023 2024 2025 2026 Jan 177.84 195.16 177.78 213.1 188.39 163.35 Feb 146.48 166.74 141.99 155.8 122.54 146.13 Mar 204.6 269.88 283.84 174.12 155.86 204.7 Apr 249.86 232.29 228.59 231.41 200.01 246.21 May 238.23 224.49 230.63 270.85 172.1 231.4 Jun 309.71 295.83 286.52 285.71 312.67 322.86 Jul 334.17 317.47 290.33 369.56 360.17 365.13 Aug 285.21 275.99 279.2 251.11 275.98 Sept 247.76 167.91 164.66 207.05 174.7 Oct 184.63 175.99 188.33 188.84 147.66 Nov 315.31 147.67 213.92 130.67 155.89 Dec 286.85 133.1 162.31 177.15 203.88 Month 2021 2022 2023 2024 2025 2026 Jan 183.07 218.4 252.78 279.78 126.21 145 Feb 156.06 190.63 188.5 182.95 212.03 123.28 Mar 282.37 215.58 176.46 236.88 286.98 212.02 Apr 256.07 231.64 248.37 288.91 366.07 249.44 May 208.32 190.02 265.62 229.39 300.94 180.87 Jun 266.23 217.88 236.52 186.2 189.64 205.54 Jul 273.08 202.64 159.51 256.16 218.83 214.01 Aug 223.64 184.78 172.83 250.74 207.4 Sept 182.96 212.11 227.8 176.09 239.25 Oct 152.16 528.77 178.51 317.18 225.59 Nov 124.04 304.19 120.6 166.13 350.71 Dec 125.14 126.89 106.2 141.64 183.77 Month 2025 2026 2027 Jan 35.07 50.14 Household Garbage (Tons) Yard Debris (Tons) Miscellaneous Garbage Collection (Tons) Public Services Department - July 2026 Report City of Isle of Palms, SC 0 50 100 150 200 250 300 350 400 Jan Feb Mar Apr May Jun Jul Aug Sept Oct Nov Dec 2023 2024 2025 2026 0 50 100 150 200 250 300 350 400 Jan Feb Mar Apr May Jun Jul Aug Sept Oct Nov Dec 2023 2024 2025 2026 50 60 6 Feb 32.09 42.84 Mar 22.25 28.92 Apr 37.1 34.49 May 38.12 25.02 Jun 24.64 34.11 Jul 28.98 15.17 CW7/8 - 2.80 tons Trident container Aug 27.3 7/16 - 4.27 tons Trident container Sept 29.06 7/24 - 4.59 tons Trident container Oct 34.36 26.83 July Nov 40.14 Dec 36.36 Month 2025 2026 Jan 0 6587 Feb 1679 5087 Mar 395 2940 Apr 358 7295 May 2010 2230 Jun 3115 5750 Jul 5530 2360 Aug 8445 Sept 2150 Oct 2140 Nov 975 Dec 2000 DATE COMPANY ZONE LOCATION ft DESCRIPTION Column1 Column2 Column3 DATE COMPANY ZONE LOCATION ft DESCRIPTION 7/2/2026 IOP 25th Ave 600 Weed eat and remove debris 7/3/2026 IOP 5th and Palm 10 Maintenance on tide valve 7/6/2026 IOP 7th palm 150 Maintenannce of right-a-way/ditches 7/8/2026 IOP 29th and Palm 50 Clean ditch 7/10/2026 IOP Citywide 250 Weed eat and remove debris from ditch line 7/28/2026 Fortis 32nd ditch 1300 Vegetation maint. of ditch line 7/26/2026 IOP City wide Cleaning of drains on July 26th storm Stormwater Management (Linear Feet) Stormwater Management 0 1000 2000 3000 4000 5000 6000 7000 8000 9000 Jan Feb Mar Apr May Jun Jul Aug Sept Oct Nov Dec 2025 2026 0 10 20 30 40 50 Jan Feb Mar Apr May Jun Jul Aug Sept Oct Nov Dec 2025 2026 2027 7 Fortis Enviornmental LLC-City of Isle of Palms drainage maintence contractor FE IOP Public Services IOP-PS Drainage maintenance Pleasant Places Drainage Maintenance LOCATION DESCRIPTION Island wide Maintenance Front beach restroom access Maintenance and repair City wide beach clean up Cleaning of beach sanitation Trident Waste-Public Services Public restroom, sea cabins, 9th 1X Regrading beach accesses Palm Blvd. 21st-41st Rights of way maintenance Beach accesses Beach access maintenance LOCATION DESCRIPTION Exterior repairs Building & Facilities Maintenance Tree removal Hazard tree removal 27h and Hartnett Carmen R Bunch Park Eagle scout landscape project scheduled City Hall Streets Street sign instalation Garbage compactor Maintenance Public Services Estimates for building interior repairs Marina UST Marina/ PSB and compliance testing City wide City wide trash clean up - FVS contracting-public services City wide UST DES Compliance teting Beach Access Paths Maintenance & Improvements Garbage compactor Cleaning weekly/powerwashing Public Services Ongoing deployment of new city garbage cans Front Beach Ongoing Plant a palm 2.0 coordination. Beach/Public Services Public services city wide clean up City Hall City Hall roof installation PSB Elevator repairs/irrigation repairs 8 Monthly Report August 2026 Isle of Palms Recreation Department Programs, Group Fitness, Athletics & Special Events September - December 2026 Activity Guide released Thursday, Aug. 6. Adult Classes: Fitness Classes and Programs with top participation: Core & More (13), Strength (12), Tabata (20), Move-It (18), Stability & Strength (17), RXFit Club (15), Suspension Training (12), and Pilates (11) Beach Yoga: Tuesdays at 7:30am through Oct. - 25th Ave Beach Access. Approximately 26 people per week. Youth Soccer: Registration closed Aug. 14. 135 youth registered for the league, practices & games start in Sept. Adult Athletics: 3 on 3 Basketball - 6 teams registered. 6 v 6 Soccer – 4 teams registered. Table Tennis - 7 people registered. Games start in Sept. Farmers Market, Food Truck Jam, Thursday, Aug. 20. 51 vendors onsite, live music and great community support. Get your Spike On Volleyball Camp: August 3 - 6 from 9am - 11am, 16 youth participated. Gymnastics Camp: Aug. 3 - 5 from 10:30am - Noon, 15 youth participated. Trading Card Lab: Aug. 4 - 6 from 3:15 - 5:15pm, Ages 7-11. 2 youth participated. 28 Annual Half Rubber Tournament: Saturday, August 8 at 8am, 8 teams participated in a double elimination tournament. Teams traveled from Savannah and Charleston areas to participate. Below Average, Charleston team won the 2026 tournament. th Tiny Chefs: Aug. 10 - Sept. 14 at 3pm. 4 youth participating. Speaker Series: Narcan Training for youth and families: Monday, Aug. 10 - 19 participated. Move Better, Live Better, Simple Strategies to stay strong & Active: Tuesday, Aug. 11 - 1 participated. Sea Stroll & Learn: Thursday, Aug. 13 - 22 participated. Art at the Rec: August 3 - October 31 the Recreation Center’s hallway & lobby are turning into an Art Walk, showcasing local talent. Artists featured to-date include - Amanda Lamontagne and Alba Ortiz. Operations Tennis Court reopened Monday, August 24. Landscape, signage and finishing touches will continue over the next few weeks. Meeting with vendors for quotes on exterior lighting upgrades at the Recreation Center. Special Elections: August 11 and August 25. Hosted IOP Chamber Meeting on August 25, facility tour, sponsorship opportunities and involvement with the Rec. IOP Connector Run: monthly meetings with board for preparations and planning of the 5K & 10K Run on October 3. Maintenance & Repairs Upcoming Programs, & Events Coffee with the Mayor: Friday, Aug. 28 at 9am Keenagers: Wednesday, September 3 at Noon. Covered dish lunch and entertainment. Free Speaker Series: Guardianship- September 8 at 6pm The Science behind water runoff - September 9 at 11am The Power of positive painting - September 15 at 11am IOP Compost Program - September 18 at 11am Connection before correction- September 28 at 5:30pm. Sea Stroll & Learn: Thursday, September 10 at 7:30am – Stingrays, Barrier Island Eco Tours. Free Farmers Market & Food Truck Jam: Thursday, September 17 from 4pm - 7pm. Mahjong Tournament: September 23 at 10am. IOP Connector Run: Saturday, October 3 at 8am. Soccer Field: replaced irrigation heads, turf field applications, treatment for moles. Prepped fields for Half Rubber Tournament, 6 v 6 soccer league and youth leagues ages 7-8 & 9-12. Basketball, Pickleball, Fitness Court: daily blowing, cleaning, trash pickup, trim and edge. Repaired fitness court tiles. Tennis Court: prepped new sidewalk at tennis courts, ordered sod and continue to work on landscaping around courts. Multi-purpose field: treatments and prep for youth soccer leagues ages 3-4 & 5-6. Cleaning and prepping island curb to be painted safety yellow. Planet Green Tree service cut 18 palm trees on Recreation grounds as a part of the city wide contract. HVAC: Berkely Heating and Air site and maintenance visit for three units. Exterior lights: replaced bulbs and cleaned lights around building. 9 Enrollment Report August 2026 Monthly Revenues 2026 Annual Comparison RecTrac WebTrac Total January February March April May June July August September October November December 0 10000 20000 30000 40000 50000 60000 70000 2023 2024 2025 2026 January February March April May June July August September October November December 0 10,000 20,000 30,000 40,000 50,000 60,000 70,000 Participants registering for classes during the month from July 31 - August 27 RecTrac: in-house registration vs. WebTrac: online Registrations. Total registrations for August: 446 Revenue sales brought in by programs, athletics and events. RecTrac: in-house vs WebTrac: online Total Revenue for August: $28,148 Year to Year RecTrac WebTrac RecTrac 67.5% WebTrac 32.5% 10 2025 2026 January February March April May June July August September October November December 0 2 4 6 8 10 12 14 2025 2026 January February March April May June July August September October November December 0 5 10 15 20 TTaalleessTales GGHHoossttllyy TTiiddeeGHostly Tide Front Beach Isle of Palms CC KIEKIE FREEFREEFREE Family Friendly Ghost Stories FREE Cardio Room Daily Average Visits Open Gym Daily Average Visits Participants utilizing the gymnasium for open play Participants utilizing the cardio room Upcoming Events: halloween Golf Cart Parade & Carnival 10.31.26 Haunted House, Games, Music, Candy & More 4pm-6pm FFrriiddaayy,, OOccttoobbeerr 1166 Friday, October 16 66ppmm6pm SATURDAY, DECEMBER 5 2PM - 7PM TREE LIGHTING 5:30PM FRONT BEACH, ISLE OF PALMS ISLE OF PALMS FOOD, CRAFTS, GIFTS, AND LIVE MUSIC, SANTA CLAUS, CARNIVAL RIDES & MORE! HOLIDAY MAGIC AWAITS! HOLIDAY STREET FESTIVAL WORKSHOPWORKSHOPWORKSHOP SANTA’SSANTA’SSANTA’S DECDECDEC 171717 4 PM4 PM4 PM IOP Connector Run Saturday, October 3 8am Mahjong Tournament September 23 10am 11 682 Johnnie Dodds Blvd., Suite 100 Mt. Pleasant, SC 29464 843.849.0200 thomasandhutton.com Project Meeting Notes Meeting Date Start End Next Meeting Next Time Prepared By August 20, 2026 9:00 AM 9:20 AM 9/3/26 9:00 AM MCV Purpose Location Waterway Blvd Pathway Construction Progress Meeting Virtual Attended By Copies To Douglas Kerr – City of Isle of Palms Sean Kuester – City of Isle of Palms Robert Asero – City of Isle of Palms Greg Parris – Bastion Rick Karkowski – Thomas & Hutton Maria Valenzuela – Thomas & Hutton Douglas Kerr Sean Kuester Robert Asero Greg Parris Rick Karkowski Maria Valenzuela Summary of Meeting 1. Schedule/ construction progress o Utility relocations complete o Drainage around 3605 – 3607 Waterway Blvd complete o Starting on drainage at Sparrow Drive o Starting curb and gutter, wall on Monday o Seewee to stabilize ditch at 22nd Avenue o Pleasant Places to start seeding 2. Wild Dunes driveway o Expected to be low cost o Murray and Robert coordination 3. AT&T coordination o AT&T waiting on SCDOT o Maria to follow up and ask for SCDOT contact 4. Change order #3 o Removal/reduction of Dewees work, driveways, and sodding o Bastion change order for unexpected utility conflicts and changes – End of Notes 12 M E E T I N G N O T E S( CO N T I N U E D) August 20, 2026 Waterway Blvd Pathway Project Above is a summary of the meeting. Notify the undersigned as soon as possible if there are any discrepancies or misunderstandings with the above notes. Please contact me if you have any questions or if there are other issues or items requiring attention. Prepared by: Maria Valenzuela MARIA VALENZUELA | Designer THOMAS & HUTTON p 843-725-5249 e valenzuela.m@tandh.com a 682 Johnnie Dodds Blvd.; Suite 100 | Mt. Pleasant, SC 29464 vCard | Website | LinkedIn | Facebook | Instagram | YouTube 13 Z:\27670\27670.0010\Documents\Construction\Change Orders\Change Order #3\Change Order No 3.docx CO–3 C O N S T R U C T I O N C O N T R A C T C H A N G E O R D E R www.thomasandhutton.com Project: Waterway Blvd. Pathway Construction Contract: Contract I Change Order Number: 3 Owner: City of Isle of Palms Date Issued: TBD Contractor: The Bastion Group, LLC Engineer’s Project Number: 27670.0010 The Contract is changed as follows: • Remove work behind fire station on 41 st and within the Dewees marina driveway, remove sod, reduce driveway replacements, and additional utility conflict work. Not valid until signed by the Owner, Engineer, and Contractor. Adjustments in the Contract Sum: The original Contract Amount was ............................................................................. $ 2,890,156.00 Net change by previously authorized Change Orders............................................ $ 102,100.50 The Contract Amount prior to this Change Order was ............................................ $ 2,992,256.50 The new Contract Amount will be (increased) (decreased) (unchanged) by this Change Order in the amount of ............................................................. $ 155,625.90 The new Contract Amount including this Change Order will be .......................... $ 2,836,630.60 Adjustments in the Contract Time: Original Substantial Completion Date ....................................................................... 07/21/2026 Sum of Previously Approved Increases and Decreases ...................... ( 56 ) days Date of Substantial Completion prior to this Change Order ................................... 09/15/2026 The Contract Time will be (increased) (decreased) (unchanged) by (0 ) days The date of Substantial Completion as a result of this Change Order therefore is 09/15/2026 E NGINEER RECOMMENDATION Richard Karkowski, PE, PH, D.WRE 08/28/2026 ENGINEER SIGNATURE D ATE CONTRACTOR ACCEPTANCE CONTRACTOR SIGNATURE D ATE OWNER APPROVAL Douglas Kerr OWNER SIGNATURE D ATE 14 NUMBER OF UNITS UNIT MEASURE UNIT PRICE TOTAL COST NUMBER OF UNITS UNIT MEASURE UNIT PRICE TOTAL COST 8 Removal & Disposal of Existing Pavement 6,685 SY 11.65$ 77,880$ (325.0) SY 11.65$ (3,786.25)$ deduct - driveways removed 9 Removal & Disposal of Existing Concrete 600 CY 20.15$ 12,090$ (249.0) CY 20.15$ (5,017.35)$ deduct - driveways removed 10 Controlled Fill - Borrow Material 750 CY 49.95$ 37,463$ (32.0) CY 49.95$ (1,598.40)$ deduct - Dewees work removed 11 Grading 11,400 SY 5.95$ 67,830$ (120) SY 5.95$ (714.00)$ deduct - Dewees work removed 12 Graded Aggregate Base Course 2,191 SY 45.00$ 98,595$ (325.00) SY 45.00$ (14,625.00)$ deduct - driveways removed 13 Hot Mix Asphalt Intermediate Course Type B 7,715 TON 22.65$ 174,745$ (0.45) TON 223.00$ (100.35)$ deduct - driveways removed 14 Hot Mix Asphalt Surface Course Type B 244 TON 223.00$ 54,412$ (0.45) TON 223.00$ (100.35)$ deduct - driveways removed 18 Concrete Driveway 550 SY 113.00$ 62,150$ (249) SY 113.00$ (28,137.00)$ deduct - driveways removed 19 Gravel Drive 220 SY 40.80$ 8,976$ (84) SY 40.80$ (3,427.20)$ deduct - Dewees work removed 44 Sodding 7.25 MSY 12,800.00$ 92,800$ (7.25) MSY 12,800.00$ (92,800.00)$ removed from contract 45 CMU Wall - Firestation 313 LF 238.00$ 74,494$ (140) LF 238.00$ (33,320.00)$ deduct - Dewees work removed Structure Adjustments 9 EA 1,000.00$ 9,000.00$ added per Bastion CO Field Coordination Delays (incorrect utility locates, etc.) 38 HR 500.00$ 19,000.00$ added per Bastion CO CONTRACT TOTAL TO DATE $2,992,256.00 CO #3 TOTAL -$155,625.90 ITEM DESCRIPTION COST NOTES: THE QUANTITIES LISTED HEREIN ARE ESTIMATES ONLY AND DO NOT CONSTITUTE ANY WARRANTY OR GUARANTEE BY THE CITY, AND SHOULD NOT BE RELIED UPON BY BIDDERS. ALL QUANTITIES MAY VARY. THE TOTALS REQUIRED ON THE BID FORM HEREIN ARE FOR INFORMAL COMPARISON ONLY. PAYMENTS WILL BE BASED UPON UNIT PRICES WHERE INDICATED. CONTRACTOR MUST BID ON ALL WORK HEREIN. City of Isle of Palms Miscellaneous Change Order #3 - Additional Line Items ADD/DEDUCT NOTES CONTRACT CHANGE ORDER #1 QUANTITY COST Earthwork Roadway and Pathway QUANTITY Waterway Blvd Pathway Change Order #3 Thomas & Hutton Sheet 1 of 1 File \Z:\27670\27670.0010\Documents\Construction\Change Orders\Change Order #3\Waterway Blvd Pathway - Change Order #3 Quantities.xlsx 15 16 17 18 19 PLOT DATE: 7/29/2026 10:53:46 AM FILE LOCATION: X:\2022\22047.ACAD\001\X\PRODUCTION.DRAWINGS\PD.0027 C L I N E E N G I N E E R I N G THIS DRAWING AND ASSOCIATED CAD FILES ARE AN INSTRUMENT OF SERVICE AND THE PROPERTY OF CLINE ENGINEERING, INC. AND SHALL NOT BE USED OR REPRODUCED IN ANY WAY OTHER THAN AUTHORIZED BY CLINE ENGINEERING, INC. IN WRITING. REV. DATE DRAWN APPV.DESCRIPTION SHEET NUMBER PROJECT MANAGER DRAWN BY PROJECT DATE JOB NUMBER PROFESSIONAL DESIGN CONSULTING 50 41ST AVENUE ISLE OF PALMS, SOUTH CAROLINA IOP MASTER PLAN 22047 AUGUST 2022 AJ/JR MDC A 07/29/2026 ISSUED FOR REVIEW AND APPROVAL -- MDC G-1 COVER site development plans for 50 41ST AVENUE ISLE OF PALMS, south carolina IOP MASTER PLAN VICINITY MAP SCALE 1" = 1000' PROJECT LOCATION ADA COMPLIANCE THE PUBLIC RIGHT-OF-WAY MUST REMAIN ADA COMPLIANT DURING CONSTRUCTION OR AN ALTERNATIVE ROUTE MUST BE PROVIDED. IT IS THE OWNERS RESPONSIBILITY TO REPAIR ALL DAMAGED SIDEWALKS TO REINSTATE AN ADA ACCESSIBLE ROUTE. PROJECT DESCRIPTION SITE IMPROVEMENTS WILL CONSIST OF THE REDEVELOPMENT OF PARKING LOT AND DRIVEWAYS. SITE CONTACTS CLIENTCIVIL ENGINEER MATTHEW CLINE, P.E. CLINE ENGINEERING P.O. BOX 21204 CHARLESTON, SC 29413 PHONE (843) 991-7239 PROJECT SURVEYOR CITY OF ISLE OF PALMS DOUGLAS KERR PO DRAWER 508 ISLE OF PALMS, SC 29451 PHONE (843) 886-6428 SOUTH CAROLINA EROSION CONTROL S.C.D.E.S. B.C.M. STORMWATER DIVISION 1362 MCMILLAN AVE. SUITE 400 CHARLESTON, SC 29405 PHONE (843) 953-0200 SOUTH CAROLINA DEPARTMENT OF TRANSPORTATION DISTRICT 6 6355 FAIN BLVD. NORTH CHARLESTON, SC 29406 PHONE (843) 740-1667 SHEET LIST TABLE SHEET NUMBERSHEET TITLE G-1 COVER G-2 GENERAL NOTES G-3 GENERAL NOTES V-1 SITE CONDITIONS C-1 SITE PLAN C-2 DEMOLITION AND SWPPP C-3 GRADING AND DRAINAGE PLAN C-4 UTILITY PLAN C-5 CONSTRUCTION DETAILS C-6 CONSTRUCTION DETAILS C-7 CONSTRUCTION DETAILS 20 PLOT DATE: 7/29/2026 10:53:53 AM FILE LOCATION: X:\2022\22047.ACAD\001\X\PRODUCTION.DRAWINGS\PD.0028 C L I N E E N G I N E E R I N G THIS DRAWING AND ASSOCIATED CAD FILES ARE AN INSTRUMENT OF SERVICE AND THE PROPERTY OF CLINE ENGINEERING, INC. AND SHALL NOT BE USED OR REPRODUCED IN ANY WAY OTHER THAN AUTHORIZED BY CLINE ENGINEERING, INC. IN WRITING. REV. DATE DRAWN APPV.DESCRIPTION SHEET NUMBER PROJECT MANAGER DRAWN BY PROJECT DATE JOB NUMBER PROFESSIONAL DESIGN CONSULTING 50 41ST AVENUE ISLE OF PALMS, SOUTH CAROLINA IOP MASTER PLAN 22047 AUGUST 2022 AJ/JR MDC A 07/29/2026 ISSUED FOR REVIEW AND APPROVAL -- MDC G-2 GENERAL NOTES SITEWORK 1. TOPOGRAPHIC AND BOUNDARY SURVEY BY OTHERS AND PROVIDED TO CLINE ENGINEERING BY CLIENT. 2. THE CONTRACTOR SHALL VERIFY THE LOCATION AND INVERT ELEVATION OF ALL UNDERGROUND UTILITIES, AND VERIFY PROPERTY CORNERS AND TOPOGRAPHY BEFORE ANY CONSTRUCTION IS BEGUN. CALL UTILITY COMPANIES BEFORE EXCAVATION TO LOCATE ALL BURIED CABLES AND UNDERGROUND UTILITIES. PRIOR TO INSTALLATION OF STORM OR SANITARY SEWER, THE CONTRACTOR SHALL VERIFY THE INVERTS OF EXISTING STRUCTURES AND INFORM THE OWNER AND THE ENGINEER OF ANY CONFLICTS PRIOR TO CONSTRUCTION. 3. THE CONTRACTOR SHOULD NOTIFY THE ENGINEERS FOR A REVIEW SHOULD DISCREPANCIES BE DISCOVERED AT THE SITE OR ON THE DRAWINGS BEFORE AND DURING CONSTRUCTION. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE BETWEEN ALL CIVIL DRAWINGS WITH GRADING AND UTILITY CONTRACTORS IN ORDER TO AVOID PROBLEMS DURING CONSTRUCTION. 4. CONTRACTOR TO SCHEDULE A PRECONSTRUCTION MEETING WITH ALL UTILITY COMPANIES PRIOR TO CONSTRUCTION. CONTRACTOR SHALL NOTIFY THE ENGINEER AND UTILITY COMPANIES DURING CONSTRUCTION OF WATER AND SEWER SO PERIODIC OBSERVATIONS CAN BE MADE. CONTRACTOR WILL CERTIFY TO THE ENGINEER IN WRITING THAT WATER AND SEWER LINES HAVE BEEN TESTED AND CONSTRUCTED ACCORDING TO THE ENGINEER'S AND UTILITY COMPANY'S DRAWINGS AND SPECIFICATIONS. 5. EXISTING DRAINAGE STRUCTURES TO BE INSPECTED AND REPAIRED AS NEEDED AND EXISTING PIPES TO BE CLEANED OUT TO REMOVE ALL SILT AND DEBRIS. 6. ALL REFERENCE TO SPECIFICATIONS FOR HIGHWAY CONSTRUCTION OR MATERIALS ARE MADE FROM SOUTH CAROLINA STATE HIGHWAY DEPARTMENT'S STANDARD SPECIFICATION, LATEST EDITION. 7. ALL DIMENSIONS SHOWN ARE MEASURED FROM OUTSIDE FACE OF BUILDING WALL AND TO FACE OF CURB LINE. MIDDLE LINE IS THE FACE OF CURB. 8. EARTHWORK SHALL BE TO THE LINES AND GRADES SHOWN. PROOF ROLLING AND COMPACTION TEST SHALL BE ACCOMPLISHED IN THE FIELD TO TEST ALL AREAS. THE OWNER SHALL RETAIN THE SERVICES OF A TESTING COMPANY TO TEST ALL AREAS. MASS AREAS OF FILL SHALL BE PLACED IN LOOSELY MEASURED LIFTS NOT EXCEEDING 8" THICKNESS. ISOLATED AREAS OF FILL (SUCH AS TRENCH BACKFILL) SHALL BE PLACED IN LIFTS NOT EXCEEDING 6" THICKNESS. 9. CONTRACTOR SHALL PROTECT ALL TREES THAT ARE TO REMAIN AS MARKED IN THE FIELD BY OWNER'S REPRESENTATIVE. 10. THE GRADING CONTRACTOR SHALL PROOF-ROLL THE CONSTRUCTION AREA WITH A FULLY-LOADED TANDEM-AXLE DUMP TRUCK, OR APPROVED EQUAL, BY MAKING 2 COMPLETE PASSES IN EACH OF 2 PERPENDICULAR DIRECTIONS. ALL SOFT SPOTS SHALL BE UNDERCUT AND RE-COMPACTED WITH SUITABLE STRUCTURAL FILL MATERIAL. MINIMUM AXLE WEIGHT = 10 TONS. 11. THE CONTRACTOR SHALL BE SOLELY AND COMPLETELY RESPONSIBLE FOR CONDITIONS OF THE JOB SITE, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY DURING PERFORMANCE OF THE WORK. THIS REQUIREMENT WILL APPLY CONTINUOUSLY AND WILL NOT BE LIMITED TO NORMAL WORKING HOURS. THE DUTY OF THE ENGINEER TO CONDUCT CONSTRUCTION REVIEW OF THE CONTRACTOR'S PERFORMANCE IS NOT INTENDED TO INCLUDE REVIEW OF THE ADEQUACY OF THE CONTRACTOR'S SAFETY MEASURES, IN, ON, OR NEAR THE CONSTRUCTION SITE. THE CONTRACTOR WILL BE RESPONSIBLE FOR PROVIDING AND MAINTAINING ALL BARRICADES, WARNING SIGNS, FLASHING LIGHTS, AND TRAFFIC CONTROL DEVICES DURING CONSTRUCTION. THE CONTRACTOR IS TO COMPLY WITH ALL OSHA REGULATIONS, REQUIREMENTS, AND SAFETY MEETING REQUIREMENTS. 12. ALL NEW ELEVATIONS SHOWN ARE FINISH GRADE ELEVATION. THE GRADING CONTRACTOR SHALL DEDUCT THE FOLLOWING FOR SUBGRADE ELEVATION: ·BUILDING FLOOR - SEE ARCHITECTURAL PLANS ·HEAVY DUTY PAVEMENT - 11" ·LIGHT DUTY PAVEMENT - 8" ·PCC PAVEMENT - 12" ·SIDEWALKS - 4" ·TURF AREAS - 4" 13. THE CONTRACTOR SHALL REMOVE ALL TREES AND VEGETATION THAT ARE WITHIN 5 FEET OF NEW CONSTRUCTION. REMOVE DEBRIS FROM SITE OR BURN IN ACCORDANCE WITH LOCAL LAWS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING NECESSARY BURNING PERMITS. PROTECT ALL TREES THAT ARE TO REMAIN. 14. TOPSOIL SHALL BE STRIPPED TO A DEPTH AS REQUIRED BY OWNER OR GEOTECH AND STOCKPILED AS DIRECTED BY THE OWNER'S REPRESENTATIVE. 15. THE TOP 18" OF FILL SHALL BE COMPACTED TO 98% OF MAXIMUM DRY DENSITY BY THE STANDARD PROCTOR METHOD ASTM D-698. ALL OTHER FILL SHALL BE COMPACTED TO 95% MAXIMUM DRY DENSITY. MOISTURE SHALL BE CONTROLLED TO WITHIN ±2% OF OPTIMUM. 16. ALL EXCAVATION SHALL BE "CLASSIFIED EXCAVATION". EXCAVATION SHALL BE "CLASSIFIED" AS "COMMON EXCAVATION" OR "ROCK EXCAVATION". ROCK EXCAVATION SHALL BE CLASSIFIED AS FOLLOWS: ·MASSIVE ROCK EXCAVATION - ANY MATERIAL WHICH CANNOT BE EXCAVATED WITH A SINGLE TOOTH RIPPER DRAWN BY A CRAWLER TRACTOR HAVING A MINIMUM DRAW BAR RATED AT NOT LESS THAN 53,000 POUNDS (CATERPILLAR D-8 OR EQUIVALENT) AND OCCUPYING AN ORIGINAL VOLUME OF AT LEAST ONE CUBIC YARD OR MORE. ·TRENCH EXCAVATION - ANY MATERIAL WHICH CANNOT BE EXCAVATED WITH A POWER SHOVEL HAVING THE CAPACITY OF AT LEAST THAT OF A CATERPILLAR 225 AND OCCUPYING AN ORIGINAL VOLUME OF AT LEAST 1/2 CUBIC YARD OR MORE. COMMON EXCAVATION SHALL INCLUDE ALL MATERIALS THAT CAN BE RIPPED, BOULDERS, AND ALL OTHER MATERIALS THAT DO NOT FALL IN THE CATEGORY OF ROCK EXCAVATION AS DEFINED ABOVE. 17. THE CLASSIFICATION OF SOILS INCLUDE: TOPSOIL, FILL MATERIAL, UNSUITABLE MATERIAL, AND ROCK EXCAVATION. THE CLASSIFICATION OF SOILS IS THE RESPONSIBILITY OF THE OWNER'S SOIL TESTING FIRM. 18. ALL FILL MATERIAL SHALL CONSIST OF AN APPROVED MATERIAL AND BE FREE OF ORGANIC MATTER AND DEBRIS. IMPORTED FILL SHALL HAVE A MINIMUM STANDARD PROCTOR MAXIMUM DRY DENSITY OF 95 PCF, CLAY/SILT FINES CONTENT NOT GREATER THAN 25%, AND A PLASTICITY INDEX LESS THAN 15%. 19. ALL EXISTING SLOPES STEEPER THAN 4:1 THAT WILL RECEIVE FILL SHALL BE PLOWED AND SCARIFIED SO NEW FILL WILL BOND WITH EXISTING SURFACE. 20. CONTRACTOR SHALL SCARIFY ALL EXISTING ASPHALT PAVEMENT BEFORE PLACING FILL, UNLESS OVERLAYING ASPHALT ONTO EXISTING ASPHALT. 21. THE GRADING CONTRACTOR SHALL CONFORM TO ELEVATIONS AND DIMENSIONS SHOWN WITHIN A TOLERANCE OF PLUS OR MINUS 0.05 FEET. (FINAL GRADED SURFACE UNDER BUILDING SLABS SHALL BE WITHIN A TOLERANCE OF 3/8" WHEN MEASURED WITH A 10' STRAIGHT EDGE). (FINAL PAVEMENT WEARING COURSE SURFACE SHALL BE WITHIN A TOLERANCE OF 3/16" WHEN MEASURED WITH A 10' STRAIGHT EDGE.) (PAVEMENT VARIATION FROM TRUE DESIGN ELEVATION SHALL BE 1/4" OR LESS.) 22. SPOT ELEVATIONS SHALL TAKE PRECEDENCE OVER CONTOURS AND SLOPES SHOWN. THE CONTRACTOR SHALL NOTIFY THE ENGINEER OF SPOT ELEVATIONS WHICH DO NOT APPEAR TO BE CONSISTENT WITH THE CONTOURS AND SLOPES. SPOT ELEVATIONS SHALL BE USED FOR SETTING ELEVATIONS OF CURB AND GUTTER AND UTILITIES. 23. IF GRADE ADJUSTMENTS ARE REQUIRED, THE CONTRACTOR SHALL NOTIFY THE THE ENGINEER TO INVESTIGATE SUCH ADJUSTMENTS. 24. GRADES SHOWN AT ALL ENTRANCES ARE DESIGN GRADES. CONTRACTOR SHALL COORDINATE GRADING IN THESE AREAS WITH THE EXISTING FEATURES IN THE FIELD AND/OR CURRENT DESIGN DRAWINGS. 25. SITE CONTRACTOR SHALL EXTEND UNDERGROUND ROOF DRAINAGE PIPING TO WITHIN 5 FT OF BUILDING FOR CONNECTION TO ROOF DOWNSPOUTS. CONNECTIONS SHALL BE COORDINATED WITH BUILDING CONTRACTOR. 26. ALL ROADS AND PARKING LOTS SHALL HAVE A MINIMUM 3'-0" WIDE GRASSED SHOULDER. A 5'-0" WIDE SHOULDER IS PREFERRED AND SHALL BE PROVIDED WHERE POSSIBLE. 27. ALL REINFORCED CONCRETE PIPE (RCP) SHALL BE CLASS III, UNLESS NOTED ON DRAWINGS WITH BELL & SPIGOT ENDS AND SHALL CONFORM TO ALL REQUIREMENTS OF ASTM C 76, LATEST EDITION, INSTALLED WITH FLEXIBLE PLASTIC (BITUMEN) GASKETS AT ALL JOINTS. GASKETS SHALL COMPLY WITH AASHTO M-198 751, TYPE B, AND SHALL BE INSTALLED IN STRICT ACCORDANCE WITH PIPE MANUFACTURER'S RECOMMENDATIONS. 28. ALL CORRUGATED PLASTIC PIPE SHALL MEET THE REQUIREMENTS OF AASHTO M-294, TYPE S, SHALL BE SMOOTH INTERIOR WITH ANNULAR CORRUGATED EXTERIOR. HI-Q SURE-LOCK 10.8 PIPE, ADS, N-12, OR APPROVED EQUAL. ALL JOINTS SHALL BE BELL AND SPIGOT AND SHALL MEET THE REQUIREMENTS OF AASHTO M-294, SHALL BE WATERTIGHT, MEETING THE REQUIREMENTS OF ASTM D 3212. THE GASKETS SHALL BE MADE OF POLYISOPRENE MEETING THE REQUIREMENTS OF ASTM F 477. INSTALLATION SHALL CONFORM TO AASHTO M-294, ASTM D-2321, AND MANUFACTURERS INSTALLATION PROCEDURES. 29. ANY REINFORCED CONCRETE PIPE WITH MORE THAN 15 FOOT OF COVER SHALL BE CLASS IV WITH O-RING JOINTS. 30. ALL STORM PIPE LENGTH AND ELEVATIONS (TOPS AND INVERTS) OF STORM DRAINAGE STRUCTURES SHOWN ON THE DRAWINGS ARE APPROXIMATE. CONTRACTOR MAY HAVE TO FIELD ADJUST AS NECESSARY DURING CONSTRUCTION. THE CONTRACTOR MAY USE PRE-CAST DRAINAGE STRUCTURES AS AN ALTERNATE FOR STRUCTURES SPECIFIED ON THIS PLAN. HOWEVER, THE OWNER AND CLINE ENGINEERING, INC. ASSUME NO RESPONSIBILITY FOR THESE STRUCTURES, AS FIELD CONDITIONS DURING CONSTRUCTION OFTEN DICTATE ADJUSTMENTS STORM DRAINAGE STRUCTURES. THE CONTRACTOR RETAINS ALL RESPONSIBILITY AND EXPENSE FOR MODIFYING THESE PRE-CAST STRUCTURES TO ACCOMMODATE THESE ADJUSTMENTS. 31. ANY REINFORCED CONCRETE PIPE STEEPER THAN 10 PERCENT MUST HAVE CONCRETE COLLARS. CORRUGATED METAL PIPE WITH HUGGER BANDS MAY BE SUBSTITUTED. THE NUMBER OF CONCRETE COLLARS AND TYPE OF STORM PIPE WILL BE DETERMINED TOGETHER BY THE CONTRACTOR AND THE ENGINEER. 32. ALL SANITARY SEWER WORK SHALL BE CONSTRUCTED TO LINES AND GRADES SHOWN AND AS DETAILED ON THE DRAWINGS. ALL MANHOLE/CLEANOUT TOP ELEVATIONS ON CIVIL DRAWINGS ARE APPROXIMATE. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO ENSURE THAT ALL MANHOLE/CLEANOUT TOPS ARE FLUSH WITH PAVEMENT FINISHED GRADE THROUGHOUT THE PROJECT. 33. THE CONTRACTOR SHALL PROVIDE STANDARD CLEAN-OUTS OR MANHOLES AT ALL BENDS AND CHANGES IN GRADE IN SEWER LINES AND CONNECTIONS TO EXISTING SEWER LINES. PIPE BEDDING AND BACKFILL SHALL BE CAREFULLY CONTROLLED. ALL SANITARY SEWER WORK SHALL COMPLY WITH LOCAL CODES AND ORDINANCES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR MEETING WITH THE LOCAL AND STATE SEWER APPROVAL AUTHORITIES TO INSURE THAT ALL MATERIALS, INSTALLATION, TESTING, AND AS-BUILT DRAWING REQUIREMENTS WILL BE TO THE SATISFACTION OF THE LOCAL AND STATE AUTHORITIES. 34. ALL WATER LINES SHALL BE INSTALLED AS SHOWN ON THE DRAWINGS. ALL PIPES, VALVES, AND FITTINGS SHALL COMPLY WITH AWWA STANDARDS, ALL LOCAL AND STATE CODES AND ORDINANCES. PIPE BEDDING AND BACKFILL SHALL BE CAREFULLY CONTROLLED. WATER LINES SHALL BE PRESSURE TESTED, AND DISINFECTED AS REQUIRED. ALL NECESSARY AS-BUILTS SHALL BE ACCOMPLISHED TO THE SATISFACTION OF THE LOCAL AUTHORITY. 35. ALL UTILITY TRENCHES SHALL BE THOROUGHLY COMPACTED AND TESTED TO PREVENT SETTLEMENT AND DAMAGE TO FUTURE PAVEMENT AND STRUCTURES. 36. ASPHALT PAVING FOR LIGHT DUTY AREAS SHALL BE CONSTRUCTED ON A PREPARED AND WELL-DRAINED SUBGRADE COMPACTED AS SPECIFIED. THE BASE COURSE SHALL BE CONSTRUCTED WITH 6" COMPACTED THICKNESS STONE BASE. THE SURFACE COURSE SHALL BE CONSTRUCTED WITH 2" COMPACTED THICKNESS ALL PAVING WORK (MATERIALS AND CONSTRUCTION) SHALL COMPLY WITH STATE SPECIFICATIONS. 37. ASPHALT PAVING FOR HEAVY DUTY AREAS SHALL BE CONSTRUCTED ON A PREPARED AND WELL-DRAINED SUBGRADE COMPACTED AS SPECIFIED. THE BASE COURSE SHALL BE CONSTRUCTED WITH 8" COMPACTED THICKNESS STONE BASE. THE BINDER COURSE SHALL BE CONSTRUCTED WITH 1.5" COMPACTED THICKNESS ASPHALT CONCRETE. THE SURFACE COURSE SHALL BE CONSTRUCTED WITH 1.5" COMPACTED THICKNESS ASPHALT CONCRETE. ALL PAVING WORK (MATERIALS AND CONSTRUCTION) SHALL COMPLY WITH STATE SPECIFICATIONS. 38. CONCRETE TRUCK PAVEMENT SHALL BE CONSTRUCTED WITH 4,000 PSI CONCRETE, 6" THICK REINFORCED WITH 6" X 6" - W2.9 X W2.9 W.W.M. JOINTS SHALL BE CONSTRUCTED AS SHOWN ON DETAILS. 39. CONCRETE SIDEWALKS SHALL BE CONSTRUCTED WITH 3,000 PSI CONCRETE, 4" THICK NON-REINFORCED WITH JOINTS AS SHOWN ON DETAILS. 40. ALL AREAS NOT COVERED BY BUILDINGS AND PAVEMENT SHALL RECEIVE TOPSOIL AND BE GRASSED IN ACCORDANCE WITH SPECIFICATIONS. 41. CONCRETE CURB AND GUTTER SHALL BE 18" WIDE WITH 6" CURB CONSTRUCTED WITH 3,000 PSI CONCRETE WITH EXPANSION JOINTS AND CONTRACTION JOINTS INSTALLED TO COMPLY WITH S.C.D.O.T. STANDARD SPECIFICATION FOR MATERIALS AND CONSTRUCTION OF CURB AND GUTTER. 42. THE GRADING CONTRACTOR SHALL MAINTAIN POSITIVE DRAINAGE AWAY FROM BUILDING AT ALL TIMES. CONTRACTOR SHALL BRING TO THE ATTENTION OF THE ENGINEER ANY AREAS THAT MAY NOT DRAIN PROPERLY DURING CONSTRUCTION. 43. GRADING CONTRACTOR SHALL INCLUDE IN COST ALL CUT/FILL AND IMPORT/EXPORT NECESSARY FOR EARTHWORK BALANCE. CONTRACTOR SHALL INCLUDE IN COST ALL WETTING/DRYING OF SOILS NECESSARY TO ACHIEVE COMPACTION PER SPECIFICATIONS. 44. THE CONTRACTOR SHALL CONFORM TO THE CONSTRUCTION SEQUENCE. 45. THE CONTRACTOR SHALL CONSTRUCT TEMPORARY SEDIMENT TRAPS BEFORE OTHER SITE GRADING AND SITEWORK IS BEGUN. THE SEDIMENT TRAPS AND SEDIMENT CONTROL DURING CONSTRUCTION SHALL COMPLY WITH ALL LOCAL CODES AND REGULATIONS. AFTER ALL SITEWORK IS COMPLETED AND GRASSING ESTABLISHED, THE GRADING CONTRACTOR SHALL REMOVE ALL SILT FROM THE SITE AND LEGALLY DISPOSE OF ALL SILT OFF-SITE AT NO ADDITIONAL COST TO THE OWNER. 46. THE CONTRACTOR SHALL NOTIFY THE OWNER'S REPRESENTATIVE WHEN INSTRUCTIONS FROM REGULATORY AGENCIES ARE RECEIVED AND COMPLY WITH INSTRUCTIONS AS DIRECTED BY THE OWNER'S REPRESENTATIVE. 47. THE CONTRACTOR SHALL CAREFULLY STUDY AND COMPARE THE CONSTRUCTION DOCUMENTS AND SHALL AT ONCE REPORT TO THE ENGINEER ANY INCONSISTENCIES OR OMISSIONS DISCOVERED. THE CONTRACTOR SHALL TAKE FIELD MEASUREMENTS TO VERIFY THAT ALL LOCATIONS ARE CORRECT PRIOR TO COMMENCING CONSTRUCTION. 48. THE CONTRACTOR SHALL NOT PERFORM ANY WORK ON ANY UTILITIES OR IN ANY PUBLIC RIGHT-OF-WAYS UNTIL HE HAS OBTAINED COPIES OF ALL NECESSARY ENCROACHMENT AND CONSTRUCTION PERMITS. ANY FIELD CHANGES WITHIN SCDOT R/W OR CHANGES THAT WOULD IMPACT SCDOT R/W WILL REQUIRE WRITTEN SCDOT APPROVAL PRIOR TO CHANGES BEING IMPLEMENTED IN THE FIELD. (E.G. DRAINAGE, GRADING, ACCESS DESIGN ETC..). 49. THE CONTRACTOR SHALL PROVIDE A TRAFFIC CONTROL PLAN FOR ALL LANE AND SHOULDER CLOSURES WILL NEED TO BE SUBMITTED FOR ALL WORK WITHIN THE R/W PRIOR TO CONSTRUCTION. NIGHT WORK COULD BE REQUIRED FOR ANY AND ALL LANE CLOSURES. 50. THE OWNER SHALL BE RESPONSIBLE FOR THE MAINTENANCE OF DRIVEWAYS AND OTHER ACCESS POINTS, INCLUDING ANY NEW DRAINAGE STRUCTURES, FOR AREAS WITHIN THE RIGHTS-OF-WAYS OF STATE MAINTAINED FACILITIES IN PERPETUITY. 51. THE CONTRACTOR SHALL BE RESPONSIBLE FOR RELOCATING ANY EXISTING UTILITIES NECESSARY FOR SITE CONSTRUCTION INCLUDING ALL PERMITS AND FEES. 52. THE CONTRACTOR SHALL VERIFY BENCH MARK LOCATION AND ELEVATION WITH SURVEYOR BEFORE BEGINNING CONSTRUCTION. 53. THE CONTRACTOR SHALL VERIFY THE LOCATIONS OF ALL EASEMENTS ON THE SITE BEFORE PROCEEDING WITH CONSTRUCTION. 54. ALL PARKING LOT STRIPING IS TO BE PER SOUTH CAROLINA D.O.T. SPECIFICATIONS AND HAVE TWO (2) COATS OF PAINT. THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING FIRE LANE STRIPING AND SIGNAGE TO MEET LOCAL REQUIREMENTS. THE BASES OF ALL LIGHT POLES, ALL SPEED BUMPS, ALL BOLLARDS, AND ALL FACES OF SIDEWALK THAT ARE NOT FLUSH WITH ASPHALT ARE TO BE PAINTED TRAFFIC YELLOW. 55. IN THE CASE OF A CONFLICT IN SPECIFICATIONS, NOTES, OR DETAILS, THE STRICTER SHALL GOVERN. DEMOLITION NOTES 1. DEMOLITION INCLUDES THE REMOVAL AND DISPOSAL OF DEMOLISHED MATERIALS, AS SHOWN ON THE DRAWINGS AND HEREIN SPECIFIED. 2. CONDITIONS EXISTING AT THE TIME OF INSPECTION FOR BIDDING PURPOSES WILL BE MAINTAINED BY THE OWNER IN SO FAR AS PRACTICABLE, HOWEVER, VARIATIONS MAY OCCUR. 3. STORAGE OR SALE OF DEMOLISHED MATERIAL ON THE SITE WILL NOT BE PERMITTED. 4. THE USE OF EXPLOSIVES WILL BE PERMITTED ONLY WHEN AUTHORIZED BY THE CONSTRUCTION PROJECT MANAGER. 5. CONDUCT DEMOLITION OPERATIONS AND THE REMOVAL OF DEBRIS TO ENSURE MINIMUM INTERFERENCE WITH ROADS, STREETS, WALKS, AND OTHER ADJACENT OCCUPIED OR USED FACILITIES OR ADJACENT CONSTRUCTION PROCESSES. 6. DO NOT CLOSE OR OBSTRUCT STREETS, WALKS OR OTHER OCCUPIED OR USED FACILITIES WITHOUT PERMISSION FROM THE CONSTRUCTION PROJECT MANAGER AND THE AUTHORITIES HAVING JURISDICTION. PROVIDE ALTERNATE ROUTES AROUND CLOSED OR OBSTRUCTED TRAFFIC WAYS IF REQUIRED BY GOVERNING REGULATIONS. 7. ENSURE THE SAFE PASSAGE OF PERSONS AROUND THE AREA OF DEMOLITION. CONDUCT OPERATIONS TO PREVENT INJURY TO ADJACENT BUILDINGS, STRUCTURES, OTHER FACILITIES, AND PERSONS. 8. PROMPTLY REPAIR DAMAGES CAUSED TO ADJACENT FACILITIES BY DEMOLITION OPERATIONS AT NO COST TO THE OWNER. 9. MAINTAIN EXISTING UTILITIES, INDICATED TO REMAIN, KEEP IN SERVICE, AND PROTECT AGAINST DAMAGE DURING DEMOLITION OPERATIONS. CONTRACTOR SHALL FIELD LOCATE AND VERIFY ALL UTILITIES ON SITE. 10. DO NOT INTERRUPT EXISTING UTILITIES SERVING OCCUPIED OR USED FACILITIES, EXCEPT WHEN AUTHORIZED IN WRITING FROM THE CONSTRUCTION PROJECT MANAGER AND THE AUTHORITIES HAVING JURISDICTION. PROVIDE TEMPORARY SERVICES DURING INTERRUPTIONS TO EXISTING UTILITIES, AS ACCEPTABLE TO THE GOVERNING AUTHORITIES. NOTIFY ALL BUSINESSES IMPACTED IN ADVANCE OF ALL SCHEDULED UTILITY INTERRUPTIONS. 11. COMPLY WITH GOVERNING REGULATIONS PERTAINING TO ENVIRONMENTAL PROTECTION. 12. DEMOLISH CONCRETE AND MASONRY IN SMALL SECTIONS. 13. COMPLETELY FILL BELOW-GRADE AREAS AND VOIDS RESULTING FROM THE DEMOLITION OF STRUCTURES BELOW GRADE. 14. PLACE FILL MATERIALS IN HORIZONTAL LAYERS NOT EXCEEDING 6" IN LOOSE DEPTH. COMPACT EACH LAYER AT OPTIMUM MOISTURE CONTENT OF THE FILL MATERIAL TO A DENSITY EQUAL TO THE ORIGINAL ADJACENT GROUND, UNLESS SUBSEQUENT EXCAVATION FOR NEW WORK IS REQUIRED. AFTER FILL PLACEMENT AND COMPACTION, GRADE THE SURFACE TO MEET ADJACENT CONTOURS AND TO PROVIDE FLOW TO SURFACE DRAINAGE STRUCTURES. 15. REMOVE FROM THE SITE DEBRIS, RUBBISH, AND OTHER MATERIALS RESULTING FROM DEMOLITION OPERATIONS, OR AS DIRECTED BY THE CONSTRUCTION PROJECT MANAGER AND LEGALLY DISPOSE OF DEBRIS "OFF-SITE". 16. ALL PIPING, FENCING AND OTHER MATERIALS THAT INTERFERE WITH NEW CONSTRUCTION SHALL BE REMOVED OR ABANDONED AS DIRECTED BY THE CONSTRUCTION PROJECT MANAGER. 17. ALL SALVAGEABLE MATERIALS WILL REMAIN THE PROPERTY OF THE OWNER. THE CONTRACTOR SHALL REMOVE AND STORE THIS MATERIAL AS DIRECTED BY THE CONSTRUCTION PROJECT MANAGER. 18. TRANSPORT MATERIALS REMOVED FROM DEMOLISHED STRUCTURES AND DISPOSE OF "OFF" SITE AS REQUIRED. DEBRIS SHALL NOT BE "BURIED" OR LEFT ON SITE EXCEPT AS ALLOWED BY ALL APPLICABLE LAWS AND BY THE GEOTECHNICAL ENGINEER. 19. THE CONTRACTOR IS TO MAINTAIN MINIMUM COVER OVER ALL UTILITY LINES THROUGHOUT CONSTRUCTION. THE CONTRACTOR IS RESPONSIBLE FOR REPAIRING ANY DAMAGE TO UTILITY LINES AT NO ADDITIONAL COST TO THE OWNER. 20. THE CONTRACTOR IS RESPONSIBLE FOR REPAIRING ANY DAMAGE TO THE SITE OR TO THE BUILDING AND IMPROVEMENTS ON THE SITE THAT OCCUR DURING CONSTRUCTION AT NO ADDITIONAL COST TO THE OWNER. 21. THE CONTRACTOR MUST VISIT SITE PRIOR TO SUBMITTING BID AND INCLUDE IN HIS PRICE ALL DEMOLITION AND DISPOSAL COSTS TO REMOVE/RELOCATE ANY AND ALL ITEMS THAT MAY INTERFERE WITH NEW CONSTRUCTION. 22. THE CONTRACTOR SHALL CONTACT ALL UTILITY COMPANIES AND COORDINATE THE DEMOLITION, REMOVAL, RELOCATION, ABANDONMENT, ETC. OF ALL UTILITIES THAT INTERFERE WITH NEW CONSTRUCTION. ANY DEMOLITION AND RELOCATION SHOWN IS SCHEMATIC ONLY. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING THE DESIGN, CONSTRUCTION, AND EASEMENTS OF ALL UTILITY WORK WITH THE APPROPRIATE UTILITIES. 23. DEMOLISH ALL EXISTING UTILITIES THAT LIE UNDER AND 10' OUTSIDE OF NEW BUILDING. THE EXISTING UTILITIES 10' OR MORE OUTSIDE NEW BUILDINGS MAY BE DRAINED AND FILLED WITH FLOWABLE FILL IF TESTING COMPANY APPROVES EXISTING BACKFILL. TEMPORARY SEEDING DESCRIPTION THE PURPOSE OF TEMPORARY SEEDING IS TO REDUCE EROSION AND SEDIMENTATION BY STABILIZING DISTURBED AREAS THAT WOULD OTHERWISE LAY BARE FOR LONG PERIODS OF TIME BEFORE THEY ARE WORKED OR STABILIZED. TEMPORARY SEEDING IS ALSO USED WHERE PERMANENT VEGETATION GROWTH IS NOT NECESSARY OR APPROPRIATE. WHEN AND WHERE TO USE IT TEMPORARY SEEDING IS USED ON EXPOSED SOIL SURFACES SUCH AS DENUDED AREAS, SOIL STOCKPILES, DIKES, DAMS, BANKS OF SEDIMENT BASINS, BANKS OF SEDIMENT TRAPS, AND TEMPORARY ROAD BANKS. TEMPORARY SEEDING PREVENTS AND LIMITS COSTLY MAINTENANCE OPERATIONS ON OTHER SEDIMENT CONTROL STRUCTURES. SEDIMENT CLEANOUT REQUIREMENTS FOR SEDIMENT BASINS, SEDIMENT, TRAPS, AND SILT FENCE IS REDUCED IF THE DRAINAGE AREA IS SEEDED WHEN GRADING AND CONSTRUCTION OPERATION ARE NOT TAKING PLACE. TEMPORARY STABILIZATION IS REQUIRED WITHIN 14 DAYS AFTER CONSTRUCTION ACTIVITY IS COMPLETE UNLESS CONSTRUCTION ACTIVITY IS GOING TO RESUME WITHIN 21 DAYS. COVER SEEDED AREAS WITH AN APPROPRIATE MULCH TO PROVIDE PROTECTION FROM THE WEATHER. WHEN THE TEMPORARY VEGETATION DOES NOT GROW QUICKLY OR THICK ENOUGH TO PREVENT EROSION, RE-SEED AS SOON AS POSSIBLE. KEEP SEEDED AREAS ADEQUATELY MOIST. IRRIGATE THE SEEDED AREA IF NORMAL RAINFALL IS NOT ADEQUATE FOR THE GERMINATION AND GROWTH OF SEEDLINGS. WATER SEEDED AREAS AT CONTROLLED RATES THAT ARE LESS THAN THE RATE AT WHICH THE SOIL CAN ABSORB WATER TO PREVENT RUNOFF. RUNOFF OF IRRIGATION WATER WASTES WATER AND CAN CAUSE EROSION. SEED SELECTION SEED SELECTION IS BASED ON GEOGRAPHICAL LOCATION, SOIL TYPE AND THE SEASON OF THE YEAR IN WHICH THE PLANTING IS TO BE DONE. USE THE TABLES IN APPENDIX C AS A GUIDE FOR CONVENTIONAL TILLAGE METHODS (PLOWING, SEEDBED PREPARATION, HYDROSEEDING, ETC). IF A FAST GROWING CROP TO NURSE THE PERMANENT SPECIE OR SPECIES IS REQUIRED, THEN USE THE MIX RATE. FAILURE TO CAREFULLY FOLLOW AGRONOMIC RECOMMENDATIONS RESULTS IN AN INADEQUATE STAND OF TEMPORARY VEGETATION THAT PROVIDES LITTLE OR NO EROSION CONTROL. INSTALLATION ·TILLAGE: IF THE AREA HAS BEEN RECENTLY PLOWED, NO TILLAGE IS REQUIRED OTHER THAN RAKING OR SURFACE ROUGHENING TO BREAK ANY CRUST THAT HAS FORMED LEAVING A TEXTURED SURFACE. DISK THE SOIL FOR OPTIMAL GERMINATION WHEN THE SOIL IS COMPACTED LESS THAN 6-INCHES. ·SOIL TESTING: SOIL TESTING IS AVAILABLE THROUGH CLEMSON UNIVERSITY COOPERATIVE EXTENSION SERVICE. ·LIME: LIME IS NOT REQUIRED FOR TEMPORARY SEEDING UNLESS A SOIL TEST SHOWS THAT THE SOIL PH IS BELOW 5.0. IT MAY BE DESIRABLE TO APPLY LIME DURING THE TEMPORARY SEEDING OPERATION TO BENEFIT THE LONG-TERM PERMANENT SEEDING. ·FERTILIZER: APPLY A MINIMUM OF 1.5 TONS OF LIME/ACRE (70 POUNDS PER 1000 SQUARE FEET) IF IT IS TO BE USED.APPLY A MINIMUM OF 500 POUNDS PER ACRE OF 10-10-10 FERTILIZER (11.5 POUNDS PER 1000 SQUARE FEET) OR EQUIVALENT DURING TEMPORARY SEEDING UNLESS A SOIL TEST INDICATES A DIFFERENT REQUIREMENT. INCORPORATE FERTILIZER AND LIME (IF USED) INTO THE TOP 4-6 INCHES OF THE SOIL BY DISKING OR OTHER MEANS WHERE CONDITIONS ALLOW. ·SEEDING: LOOSEN THE SOIL SURFACE BEFORE BROADCASTING THE SEED. APPLY SEED EVENLY BY THE MOST CONVENIENT METHOD AVAILABLE FOR THE TYPE OF SEED USED AND THE LOCATION OF THE TEMPORARY SEEDING. TYPICAL APPLICATION METHODS INCLUDE BUT ARE NOT LIMITED TO CYCLONE SEEDERS, ROTARY SPREADERS, DROP SPREADERS, BROADCAST SPREADERS, HAND SPREADERS, CULTIPACKER SEEDER, AND HYDRO-SEEDERS. COVER APPLIED SEED BY RAKING OR DRAGGING A CHAIN, AND THEN LIGHTLY FIRM THE AREA WITH A ROLLER OR CULTIPACKER. ·MULCHING: USE MULCH WITH TEMPORARY SEED APPLICATIONS TO RETAIN SOIL MOISTURE AND REDUCE EROSION DURING THE ESTABLISHMENT OF VEGETATION. TYPICAL MULCH APPLICATIONS INCLUDE STRAW, WOOD FIBER, HYDROMULCHES, BFM AND FGM. USE HYDROMULCHES WITH A MINIMUM BLEND OF 70% WOOD FIBERS. THE MOST COMMONLY ACCEPTED MULCH USED IN CONJUNCTION WITH TEMPORARY SEEDING IS SMALL GRAIN STRAW. THIS STRAW SHOULD BE DRY AND FREE FROM MOLD DAMAGE AND NOXIOUS WEEDS. THE STRAW MAY NEED TO BE ANCHORED WITH NETTING OR EMULSIONS TO PREVENT IT FROM BEING BLOWN OR WASHED AWAY. APPLY THE STRAW MULCH BY HAND OR MACHINE AT THE RATE 1.5-2 TONS PER ACRE (90 POUNDS PER 1000 SQUARE FEET). FREQUENT INSPECTIONS ARE NECESSARY TO CHECK THAT CONDITIONS FOR GROWTH ARE GOOD. ·IRRIGATION: SEEDED AREAS SHOULD BE KEPT ADEQUATELY MOIST. IRRIGATE THE SEEDED AREA IF NORMAL RAINFALL IS NOT ADEQUATE FOR THE GERMINATION AND GROWTH OF SEEDLINGS. WATER SEEDED AREAS AT CONTROLLED RATES THAT ARE LESS THAN THE RATE AT WHICH THE SOIL CAN ABSORB WATER TO PREVENT RUNOFF. RUNOFF OF IRRIGATION WATER WASTES WATER AND CAN CAUSE EROSION. ·RE-SEEDING: RE-SEED AREAS WHERE SEEDING DOES NOT GROW QUICKLY, THICK ENOUGH, OR ADEQUATELY TO PREVENT EROSION. BASE SEED SELECTION SHOULD ON THE REQUIREMENTS OF LOCAL SPECIFICATIONS. INSPECTION AND MAINTENANCE ·INSPECT EVERY 7 CALENDAR DAYS AND WITHIN 24-HOURS AFTER EACH RAINFALL EVENT THAT PRODUCES ½-INCHES OR MORE OF PRECIPITATION. ·COVER SEEDED WITH MULCH TO PROVIDE PROTECTION. FREQUENT INSPECTIONS ARE NECESSARY TO CHECK THAT CONDITIONS FOR GROWTH ARE GOOD. ·SUPPLY TEMPORARY SEEDING WITH ADEQUATE MOISTURE. SUPPLY WATER AS NEEDED, ESPECIALLY IN ABNORMALLY HOT OR DRY WEATHER OR ON ADVERSE SITES. CONTROL WATER APPLICATION RATES TO PREVENT RUNOFF. ·BASE SEED SELECTION ON LOCAL SPECIFICATIONS. ·RE-SEED AREAS WHERE THE PLANTS DO NOT GROW QUICK ENOUGH, THICK ENOUGH, OR ADEQUATELY ENOUGH TO PREVENT EROSION SHOULD BE RE-SEEDED. PERMANENT SEEDING DESCRIPTION CONTROLLING RUNOFF AND PREVENTING EROSION BY ESTABLISHING A PERENNIAL VEGETATIVE COVER WITH SEED. WHEN AND WHERE TO USE IT A MAJOR CONSIDERATION IN THE SELECTION OF THE TYPE OF PERMANENT GRASS TO ESTABLISH IS THE INTENDED USE OF THE LAND. LAND USE IS SEPARATED IN TO TWO CATEGORIES, HIGH-MAINTENANCE AND LOW-MAINTENANCE. ·HIGH-MAINTENANCE: HIGH MAINTENANCE AREAS ARE MOWED FREQUENTLY, LIME OR FERTILIZED ON A REGULAR BASIS, AND REQUIRE MAINTENANCE TO AN AESTHETIC STANDARD. LAND USES WITH HIGH MAINTENANCE GRASSES INCLUDE HOMES, INDUSTRIAL PARKS, SCHOOLS, CHURCHES, AND RECREATIONAL AREAS SUCH AS PARKS, ATHLETIC FIELDS, AND GOLF COURSES. ·LOW-MAINTENANCE: LOW MAINTENANCE AREAS ARE MOWED INFREQUENTLY, IF AT ALL, AND LIME AND FERTILIZER MAY NOT BE APPLIED ON A REGULAR SCHEDULE. THESE AREAS ARE NOT SUBJECT TO INTENSE USE AND DO NOT REQUIRE A UNIFORM APPEARANCE. THE VEGETATION MUST BE ABLE TO SURVIVE WITH LITTLE MAINTENANCE OVER LONG PERIODS OF TIME. GRASS AND LEGUME MIXTURES ARE FAVORED IN THESE AREAS BECAUSE LEGUMES ARE CAPABLE OF FIXING NITROGEN IN THE SOIL FOR THEIR OWN USE AND THE USE OF THE GRASSES AROUND THEM. LAND USES REQUIRING LOW-MAINTENANCE GRASSES INCLUDE STEEP SLOPES, STREAM AND CHANNEL BANKS, ROAD BANKS, AND COMMERCIAL AND INDUSTRIAL AREAS WITH LIMITED ACCESS. SEED SELECTION THE USE OF NATIVE SPECIES IS PREFERRED WHEN SELECTING VEGETATION. BASE PLANT SEED SELECTION ON GEOGRAPHICAL LOCATION, THE TYPE OF SOIL, THE SEASON OF THE YEAR IN WHICH THE PLANTING IS TO BE DONE, AND THE NEEDS AND DESIRES OF THE PERMANENT LAND USER. FAILURE TO CAREFULLY FOLLOW AGRONOMIC RECOMMENDATIONS RESULTS IN AN INADEQUATE STAND OF PERMANENT VEGETATION THAT PROVIDES LITTLE OR NO EROSION CONTROL. INSTALLATION ·TOPSOIL: APPLY TOPSOIL IF THE SURFACE SOIL OF THE SEEDBED IS NOT ADEQUATE FOR PLANT GROWTH. ·TILLAGE: IF THE AREA HAS BEEN RECENTLY PLOWED, NO TILLAGE IS REQUIRED OTHER THAN RAKING OR SURFACE ROUGHENING TO BREAK ANY CRUST THAT HAS FORMED LEAVING A TEXTURED SURFACE. DISK THE SOIL FOR OPTIMAL GERMINATION WHEN THE SOIL IS COMPACTED LESS THAN 6-INCHES. IF THE SOIL IS COMPACTED MORE THAN 6-INCHES, SUB-SOILED AND DISK THE AREA. ·SOIL TESTING: SOIL TESTING IS AVAILABLE THROUGH CLEMSON UNIVERSITY COOPERATIVE EXTENSION SERVICE. ·LIME: UNLESS A SPECIFIC SOIL TEST INDICATES OTHERWISE, APPLY 1½ TONS OF GROUND COURSE TEXTURED AGRICULTURAL LIMESTONE PER ACRE (70 POUNDS PER 1000 SQUARE FEET). ·FERTILIZER: APPLY A MINIMUM OF 1000 POUNDS PER ACRE OF A COMPLETE 10-10-10 FERTILIZER (23 POUNDS PER 1000 SQUARE FEET) OR EQUIVALENT DURING PERMANENT SEEDING OF GRASSES UNLESS A SOIL TEST INDICATES A DIFFERENT REQUIREMENT. INCORPORATE FERTILIZER AND LIME (IF USED) INTO THE TOP 4-6 INCHES OF THE SOIL BY DISKING OR OTHER MEANS WHERE CONDITIONS ALLOW. DO NOT MIX THE LIME AND THE FERTILIZER PRIOR TO THE FIELD APPLICATION. ·SEEDING: LOOSEN THE SURFACE OF THE SOIL JUST BEFORE BROADCASTING THE SEED. EVENLY APPLY SEED BY THE MOST CONVENIENT METHOD AVAILABLE FOR THE TYPE OF SEED APPLIED AND THE LOCATION OF THE SEEDING. TYPICAL APPLICATION METHODS INCLUDE BUT ARE NOT LIMITED TO CYCLONE SEEDERS, ROTARY SPREADERS, DROP SPREADERS, BROADCAST SPREADERS, HAND SPREADERS, CULTIPACKER SEEDER, AND HYDRO-SEEDERS. COVER APPLIED SEED BY RAKING OR DRAGGING A CHAIN OR BRUSH MAT, AND THEN LIGHTLY FIRM THE AREA WITH A ROLLER OR CULTIPACKER. DO NOT ROLL SEED THAT IS APPLIED WITH A HYDRO-SEEDER AND HYDRO-MULCH. ·MULCHING: COVER ALL PERMANENT SEEDED AREAS WITH MULCH IMMEDIATELY UPON COMPLETION OF THE SEEDING APPLICATION TO RETAIN SOIL MOISTURE AND REDUCE EROSION DURING ESTABLISHMENT OF VEGETATION. APPLY THE MULCH EVENLY IN SUCH A MANNER THAT IT PROVIDES A MINIMUM OF 75% COVERAGE. TYPICAL MULCH APPLICATIONS INCLUDE STRAW, WOOD FIBER, HYDROMULCHES, BFM AND FGM. USE HYDROMULCHES WITH A MINIMUM BLEND OF 70% WOOD FIBERS. THE MOST COMMONLY ACCEPTED MULCH USED IN CONJUNCTION WITH PERMANENT SEEDING IS SMALL GRAIN STRAW. SELECT STRAW THAT IS DRY AND FREE FROM MOLD DAMAGE AND NOXIOUS WEEDS. THE STRAW MAY NEED TO BE ANCHORED WITH NETTING OR ASPHALT EMULSIONS TO PREVENT IT FROM BEING BLOWN OR WASHED AWAY. APPLY STRAW MULCH BY HAND OR MACHINE AT THE RATE 2 TONS PER ACRE (90 POUNDS PER 1000 SQUARE FEET). FREQUENT INSPECTIONS ARE NECESSARY TO CHECK THAT CONDITIONS FOR GROWTH ARE GOOD. ·IRRIGATION: KEEP PERMANENT SEEDED AREAS ADEQUATELY MOIST, ESPECIALLY LATE IN THE SPECIFIC GROWING SEASON. IRRIGATE THE SEEDED AREA IF NORMAL RAINFALL IS NOT ADEQUATE FOR THE GERMINATION AND GROWTH OF SEEDLINGS. WATER SEEDED AREAS AT CONTROLLED RATES THAT ARE LESS THAN THE RATE AT WHICH THE SOIL CAN ABSORB WATER TO PREVENT RUNOFF. RUNOFF OF IRRIGATION WATER WASTES WATER AND CAN CAUSE EROSION. ·RE-SEEDING: INSPECT PERMANENTLY SEEDED AREAS FOR FAILURE, MAKE NECESSARY REPAIRS AND RE-SEED OR OVERSEED WITHIN THE SAME GROWING SEASON IF POSSIBLE. IF THE GRASS COVER IS SPARSE OR PATCHY, RE-EVALUATE THE CHOICE OF GRASS AND QUANTITIES OF LIME AND FERTILIZER APPLIED. FINAL STABILIZATION BY PERMANENT SEEDING OF THE SITE REQUIRES THAT IT BE COVERED BY A 70% COVERAGE RATE. INSPECTION AND MAINTENANCE FOR PERMANENT SEEDING ·INSPECT SEEDED AREAS FOR FAILURE AND MAKE NECESSARY REPAIRS AND RE-SEED IMMEDIATELY. CONDUCT A FOLLOW-UP SURVEY AFTER ONE YEAR AND REPLACE FAILED PLANTS WHERE NECESSARY. ·IF VEGETATIVE COVER IS INADEQUATE TO PREVENT RILL EROSION, OVERSEED AND FERTILIZE IN ACCORDANCE WITH SOIL TEST RESULTS. ·IF A STAND OF PERMANENT VEGETATION HAS LESS THAN 40 PERCENT COVER, RE-EVALUATE CHOICE OF PLANT MATERIALS AND QUANTITIES OF LIME AND FERTILIZER. ·RE-ESTABLISH THE STAND FOLLOWING SEED BED PREPARATION AND SEEDING RECOMMENDATIONS, OMITTING LIME AND FERTILIZER IN THE ABSENCE OF SOIL TEST RESULTS. ·IF THE SEASON PREVENTS RE-SOWING, MULCH IS AN EFFECTIVE TEMPORARY COVER. ·FINAL STABILIZATION OF THE SITE REQUIRES A 70 PERCENT OVERALL COVERAGE RATE. THIS DOES NOT MEAN THAT 30 PERCENT OF THE SITE CAN REMAIN BARE. THE COVERAGE IS DEFINED AS LOOKING AT A SQUARE YARD OF COVERAGE, IN WHICH 70 PERCENT OF THAT SQUARE YARD IS COVERED WITH VEGETATION. TEMPORARY SEEDING - COASTAL SPECIESRATES PER ACREPLANTING DATES SANDY, DROUGHTY SITES BROWNTOP MILLET40 LBS.MAR. 10 - SEPT. 1 RYE, GRAIN56 LBS.SEPT. 1 - MAR. 15 RYEGRASS50 LBS.SEPT. 1 - APR. 15 WELL DRAINED, CLAYEY/LOAMEY SITES BROWNTOP MILLET OR JAPANESE MILLET40 LBS.MAR. 15 - SEPT. 1 RYE, GRAIN OR OATS 56 LBS. 75 LBS. SEPT. 1 - MAR. 15 RYEGRASS50 LBS.SEPT. 1 - APR. 15 PERMANENT SEEDING - COASTAL SPECIESRATES PER ACREPLANTING DATES SANDY, DROUGHTY SITES BROWNTOP MILLET BAHIAGRASS 10 LBS. 40 LBS. MAR. 10 - SEPT. 1 BROWNTOP MILLET BAHIAGRASS SERICEA LESPEDEZA 10 LBS. 30 LBS. 40 LBS. MAR. 10 - SEPT. 1 BROWNTOP MILLET ATLANTIC COASTAL PANICGRASS 10 LBS. 15 LBS. PLS MAR. 10 - JUN. 25 BROWNTOP MILLET SWITCHGRASS (ALAMO) LITTLE BLUESTEM SERICEA LESPEDEZA 10 LBS. 8 LBS. PLS 4 LBS. 20 LBS. MAR. 10 - JUN. 25 BROWNTOP MILLET WEEPING LOVEGRASS 10 LBS. 8 LBS. MAR. 10 - JUN. 25 WELL DRAINED, CLAYEY/LOAMEY SITES BROWNTOP MILLET BAHIAGRASS 10 LBS. 40 LBS. MAR. 15 - SEPT. 1 RYE, GRAIN BAHIAGRASS CLOVER, CRIMSON (ANNUAL) 10 LBS. 40 LBS. 5 LBS. SEPT. 1 - NOV. 10 BROWNTOP MILLET BAHIAGRASS SERICEA LESPEDEZA 10 LBS. 30 LBS. 40 LBS. MAR. 15 - SEPT. 1 BROWNTOP MILLET BERMUDA, COMMON SERICEA LESPEDEZA 10 LBS. 10 LBS. 40 LBS. MAR. 15 - SEPT. 1 BROWNTOP MILLET BERMUDA, COMMON KOBE LESPEDEZA (ANNUAL) 10 LBS. 12 LBS. 10 LBS. MAR. 15 - SEPT. 1 BROWNTOP MILLET BAHIAGRASS BERMUDA, COMMON SERICEA LESPEDEZA 10 LBS. 20 LBS. 6 LBS. 40 LBS. MAR. 15 - SEPT. 1 BROWNTOP MILLET SWITCHGRASS LITTLE BLUESTEM INDIANGRASS 10 LBS. 8 LBS. PLS 3 LBS. PLS 3 LBS. PLS MAR. 15 - SEPT. 1 21 PLOT DATE: 7/29/2026 10:53:55 AM FILE LOCATION: X:\2022\22047.ACAD\001\X\PRODUCTION.DRAWINGS\PD.0028 C L I N E E N G I N E E R I N G THIS DRAWING AND ASSOCIATED CAD FILES ARE AN INSTRUMENT OF SERVICE AND THE PROPERTY OF CLINE ENGINEERING, INC. AND SHALL NOT BE USED OR REPRODUCED IN ANY WAY OTHER THAN AUTHORIZED BY CLINE ENGINEERING, INC. IN WRITING. REV. DATE DRAWN APPV.DESCRIPTION SHEET NUMBER PROJECT MANAGER DRAWN BY PROJECT DATE JOB NUMBER PROFESSIONAL DESIGN CONSULTING 50 41ST AVENUE ISLE OF PALMS, SOUTH CAROLINA IOP MASTER PLAN 22047 AUGUST 2022 AJ/JR MDC A 07/29/2026 ISSUED FOR REVIEW AND APPROVAL -- MDC G-3 GENERAL NOTES WATER LINES 1. ALL WATER LINES SHALL BE INSTALLED IN ACCORDANCE WITH THE SPECIFICATIONS AND DETAILS. ALL MATERIALS AND PRODUCTS THAT CONTACT POTABLE WATER MUST BE THIRD PARTY CERTIFIED AS MEETING THE SPECIFICATIONS OF ANSI/NSF STANDARD 61. ALL PIPING MATERIALS AND INSTALLATION SHALL MEET THE APPROVAL OF THE LOCAL AUTHORITY AND THE STATE HEALTH AUTHORITY. 2. ALL DUCTILE IRON PIPE (DIP) SHALL BE PRESSURE CLASS "350" CONFORMING TO AWWA C151. ALL FITTINGS SHALL BE EITHER MECHANICAL OR PUSH-ON JOINT AND SHALL COMPLY WITH AWWA C110. ALL POLY-VINYL CHLORIDE WATER LINES 4" AND SMALLER SHALL BE CLASS 200 -SDR21 CONFORMING TO ASTM D-2241 AND ASTM D-1784. WATER LINES 6" AND LARGER SHALL BE 235, DR18, JM EAGLE OR APPROVED EQUAL CONFORMING TO AWWA C-900 AND N.S.F. APPROVED. A DETECTABLE TAPE WITH THE WORDS "CAUTION: WATERLINE BURIED BELOW" SHALL BE INSTALLED 6" TO 12" ABOVE THE PIPE. 3. SEAMLESS COPPER TUBING, 3" AND SMALLER SHALL BE TYPE "K" ROLL FORM TO COMPLY WITH ASTM B-88, LATEST REVISION AND SHALL BE INSTALLED WITH WROUGHT COPPER (95-5 TIN ANTIMONY SOLDER JOINT) FITTINGS IN ACCORDANCE WITH ASTM B16.22. 4. ALL WATER LINES SHALL BE PRESSURE TESTED TO 1.5 TIMES THE MAXIMUM WORKING PRESSURE, 150 PSIG (MINIMUM), CLEANED, STERILIZED, AND FLUSHED UNTIL TWO SUCCESSIVE SATISFACTORY WATER BACTERIOLOGICAL SAMPLES TAKEN AT LEAST 24 HOURS APART ARE OBTAINED. THE SAMPLES SHALL BE ANALYZED BY A STATE APPROVED LABORATORY. THE RESULTS SHALL INCLUDE BOTH COLIFORM AND NON-COLIFORM GROWTH. ALL BACKFLOW PREVENTION DEVICES SHALL BE INSPECTED AND CERTIFIED BY A LICENSED INSPECTOR. 5. ALL FIRE HYDRANTS SHALL COMPLY WITH AWWA C502 AND MEET THE APPROVAL OF THE LOCAL WATER AUTHORITY. 6. ALL GATE VALVES SHALL COMPLY WITH AWWA C500, 175 PSI WORKING PRESSURE AND MEET THE APPROVAL OF THE LOCAL WATER AUTHORITY. 7. A MINIMUM OF A DOUBLE CHECK VALVE (BACKFLOW PREVENTOR) ASSEMBLY SHALL BE INSTALLED ON ALL LINES DEDICATED FOR FIRE LINE SPRINKLER SYSTEMS IN A MANNER ACCEPTABLE TO THE LOCAL AUTHORITY. A BACKFLOW PREVENTION DEVICE MEETING STATE AND LOCAL REQUIREMENTS SHALL BE INSTALLED ON ALL DOMESTIC WATER LINES. 8. ALL PIPE MATERIAL, SOLDER AND FLUX SHALL BE LEAD FREE (LESS THAN 0.2% LEAD IN SOLDER AND FLUX AND LESS THAN 8.0% LEAD IN PIPES AND FITTINGS). LUBRICANTS WHICH WILL SUPPORT MICROBIOLOGICAL GROWTH SHALL NOT BE USED FOR SLIP ON JOINTS. VEGETABLE SHORTENING SHALL NOT BE USED TO LUBRICATE JOINTS. NATURAL RUBBER OR OTHER MATERIAL WHICH WILL SUPPORT MICROBIOLOGICAL GROWTH MAY NOT BE USED FOR ANY GASKETS, O-RINGS, AND OTHER PRODUCTS USED FOR JOINTING PIPES, SETTING METERS OR VALVES, OR OTHER APPURTENANCES WHICH WILL EXPOSE THE MATERIAL TO THE WATER. 9. ALL WATER LINES SHALL BE INSPECTED BY THE UTILITY COMPANY AND THE ENGINEER AND CERTIFIED TO THE STATE HEALTH AUTHORITY BEFORE ACCEPTANCE AND A PERMIT TO OPERATE WILL BE ISSUED AS REQUIRED. 10. ALL WATER LINE SHALL HAVE A MINIMUM 3'-0" COVER. 11. WATER LINE SHALL BE INSTALLED AFTER SANITARY SEWER LINES ARE COMPLETE WHERE THEY CROSS. CONTRACTOR SHALL MAINTAIN A 10' HORIZONTAL AND 2' VERTICAL CLEARANCE OF WATER AND SEWER LINES. ALL WATER LINES SHALL CROSS ABOVE SEWER LINES. 12. CONTRACTOR SHALL INCLUDE COST OF METER AND TAP FEES IN PROPOSAL. THE CONTRACTOR WILL BE RESPONSIBLE FOR ALL EXCAVATION, COORDINATION AND SCHEDULING OF TAPS. THE CONTRACTOR WILL INSTALL WATER METER AND BOX AS FURNISHED BY THE LOCAL AUTHORITY AND INSTALL SERVICES LINES TO WITHIN 5' OF BUILDING AS INDICATED ON THE DRAWINGS. 13. THE CONTRACTOR WILL FOLLOW PROCEDURES AS DIRECTED TO FLUSH, STERILIZE AND FURNISH WATER SAMPLES FOR TESTING AS PER AWWA 651 UNTIL APPROVAL IS GRANTED BY THE STATE HEALTH AUTHORITY AND THE LOCAL WATER SYSTEM. A PERMIT TO OPERATE WILL NOT BE ISSUED UNTIL THE COMPLETED WATER SYSTEM MEETS ALL REQUIRED STATE AND LOCAL APPROVALS. THE CONTRACTOR IS RESPONSIBLE TO FURNISH THE OWNER WITH A COMPLETED AND APPROVED WATER SYSTEM ALONG WITH A SET OF APPROVED AS-BUILT DRAWINGS IN A FORMAT ACCEPTABLE TO THE LOCAL UTILITY AUTHORITY. 14. THE CONTRACTOR SHALL NOT PERFORM ANY WORK UNTIL HE HAS OBTAINED COPIES OF ALL NECESSARY ENCROACHMENT AND CONSTRUCTION PERMITS. 15. THE CONTRACTOR IS RESPONSIBLE FOR CONTACTING THE LOCAL WATER AUTHORITY AND DETERMINING THE REQUIREMENTS AND PROCEDURES FOR OBTAINING THE AUTHORITY'S APPROVAL OF THE WATER SYSTEM PRIOR TO SUBMITTING A PRICE TO THE OWNER. THE DETAILS AND SPECIFICATIONS OF THE LOCAL WATER AUTHORITY SHALL GOVERN. SANITARY SEWER LINES 1. ALL CONSTRUCTION SHALL BE PER THE LOCAL SEWER UTILITY'S REQUIREMENTS AND SPECIFICATIONS. 2. THE PLUMBER IS RESPONSIBLE FOR SETTING INVERT ELEVATIONS, PIPE SLOPES, ETC MEETING ALL LOCAL AND STATE CODES. 3. EACH JOINT SHALL BE CLEARLY AND LEGIBLY MARKED WITH THE MANUFACTURER'S NAME OR IDENTIFYING SYMBOL WITH THE LETTERS E.S. APPEARING ON THE EXTERIOR OF THE PIPE NEAR THE SOCKET. 4. A MINIMUM OF 3 FEET OF COVER SHALL BE MAINTAINED OVER ALL PVC PIPE LINES. 5. WATER LINES SHALL BE INSTALLED AFTER ALL GRAVITY SEWER LINES ARE INSTALLED. 6. THIS CONTRACTOR SHALL VERIFY THE LOCATION OF ALL EXISTING UNDERGROUND UTILITIES BEFORE COMMENCING WORK. CONTACT WATER, TELEPHONE, POWER AND GAS COMPANY BEFORE EXCAVATION IS BEGUN. 7. THIS CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SURVEY WORK NECESSARY TO STAKE SEWER LINES. THE CENTERLINE AND ALL CLEANOUT LOCATIONS SHALL BE STAKED IN THE FIELD. THE OWNER'S SURVEYOR WILL SET ALL LOT CORNERS. THE CONTRACTOR SHALL PROTECT ALL PROPERTY MARKERS. 8. ALL UTILITY TRENCHES SHALL BE THOROUGHLY COMPACTED TO PREVENT SETTLEMENT AND DAMAGE TO FUTURE PAVEMENT AND STRUCTURES. 9. THE CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIRS TO EXISTING ROADS USED BY HIS OPERATION. THE CONTRACTOR SHALL REMOVE MUD AND DEBRIS FROM HIGHWAY AND NOT ALLOW DUST TO BECOME A NUISANCE OR SAFETY HAZARD. 10. ALL SANITARY SEWER WORK SHALL BE CONSTRUCTED TO LINES AND GRADES SHOWN AS DETAILED ON THE DRAWING. THE CONTRACTOR SHALL PROVIDE STANDARD MANHOLES OR CLEAN-OUTS AT ALL BENDS AND CHANGES IN GRADE IN SEWER LINES AND CONNECTIONS TO EXISTING SEWER LINES. PIPE BEDDING AND BACKFILL SHALL BE CAREFULLY CONTROLLED. ALL SANITARY SEWER WORK SHALL COMPLY WITH LOCAL CODES AN ORDINANCES. THE ENGINEER, THE LOCAL AUTHORITY AND THE STATE HEALTH AUTHORITY MUST INSPECT ALL SEWER WORK AS REQUIRED BEFORE BEING PUT IN SERVICE. 11. ALL WORK SHALL BE CONSTRUCTED IN STRICT ACCORDANCE WITH THE PLANS AND SPECIFICATIONS AND INSTRUCTIONS GIVEN BY THE OWNER'S REPRESENTATIVE, THE STATE HEALTH AUTHORITY AND THE LOCAL GOVERNING AUTHORITY. 12. ALL SEWER LINES IN RELATION TO WATER LINES MUST CONFORM TO "TEN STATES STANDARDS", SECTION 38.3, 1990 EDITION, AT A MINIMUM. MAINTAIN A MINIMUM OF 10' HORIZONTAL AND 2' VERTICAL SEPARATION BETWEEN THE WATER AND SANITARY SEWER LINES. WATER LINES SHALL CROSS OVER SANITARY SEWER LINES. 13. CONTRACTOR TO ASSUME CLASS "B" BEDDING FOR SDR-26 PVC IN HIS BID PROPOSAL. CLASS "A" BEDDING WILL BE PAID FOR AS AN "EXTRA" SHOULD FIELD CONDITIONS REQUIRE THIS BEDDING. 14. COUPLINGS SHALL BE EASTERN STANDARD SEWER REPAIR COUPLINGS AS MANUFACTURED BY MISSION RUBBER COMPANY, INC. CATALOG NO. 0408-807 (8640) 0410-704 (0636), OR 0412-6250 (2636), OR AS MANUFACTURED BY FERNCO JOINT SEALER CO., FERNDALE, MICHIGAN, OR APPROVED EQUAL. 15. SANITARY SEWER SERVICES SHALL BE INSTALLED PER DETAILS. LOCATION OF SERVICE LINES SHALL BE MEASURED FROM MANHOLES AND FURNISHED WITH "AS-BUILT" DRAWINGS TO THE ENGINEER. EACH BUILDING SHALL HAVE (1) 6" OR 4" SERVICE LINE, AS SPECIFIED FOR ON THE DRAWINGS, BROUGHT TO WITHIN 5' OF THE BUILDING. SERVICE LINES SHALL BE INSTALLED AS REQUIRED ON PLANS. MINIMUM SLOPE AND CLEANOUT SPACING SHALL 1.04% FOR 6" AND 2.08% FOR 4" SERIES. 16. ALL WATER AND SEWER LINE BACKFILL SHALL BE COMPACTED TO 95% STD. PROCTOR BY CONTRACTOR. THE OWNER SHALL TEST COMPACTION. 17. THE OWNER SHALL PAY ALL SEWER TAP FEES TO THE LOCAL GOVERNING AUTHORITY. THE CONTRACTOR SHALL COORDINATE WITH LOCAL AUTHORITY ON SEWER TAPS. 18. THIS CONTRACTOR SHALL SHORE TRENCH EXCAVATION AND USE PIPE BOX TO COMPLY WITH ALL OSHA SAFETY REGULATIONS. IT IS THE CONTRACTORS SOLE RESPONSIBILITY TO PROVIDE JOB SITE SAFETY AND COMPLY WITH ALL SAFETY REQUIREMENTS. THE CONTRACTOR IS RESPONSIBLE FOR HIS MEANS AND METHODS OF CONSTRUCTION. 19. POLYVINYL CHLORIDE (PVC) 8" AND LARGER SHALL CONFORM TO ASTM D-3034, SDR-26, INSTALLED IN ACCORDANCE WITH ASTM D-2321. ELASTOMERIC JOINTS SHALL COMPLY WITH ASTM D-3212. SDR-26 SHALL BE INSTALLED IN CLASS "B" BEDDING AS DETAILED ON THE DRAWINGS. PVC SEWER 6" AND SMALLER SHALL CONFORM TO SCHEDULE 40. 20. DUCTILE IRON SHALL BE PRESSURE CLASS "350", CONFORMING TO AWWA C151, FURNISHED AND INSTALLED IN ACCORDANCE WITH THE SPECIFICATIONS. JOINTS IN DIP AT THE CREEK CROSSING SHALL BE RESTRAINED FROM MOVEMENT (LOK-TIGHT OR APPROVED EQUAL). 21. THE CONTRACTOR IS RESPONSIBLE FOR CONTACTING THE LOCAL SEWER AUTHORITY AND DETERMINING THE REQUIREMENTS AND PROCEDURES FOR OBTAINING THE AUTHORITY'S APPROVAL OF THE SEWER SYSTEM PRIOR TO SUBMITTING A PRICE TO THE OWNER. THE DETAILS AND SPECIFICATIONS OF THE LOCAL SEWER AUTHORITY SHALL GOVERN. 22. MANHOLE FRAME AND COVER SHALL BE MF-11 AND MC-18 RESPECTIVELY AS MANUFACTURED BY SUMTER MACHINERY COMPANY OR SEWER AUTHORITY APPROVED EQUAL. FRAME SHALL WEIGH 208 POUNDS AND COVER SHALL WEIGH 120 POUNDS. ALL SURFACES OF FRAME AND COVER SHALL BE BITUMINOUS COATED. 23. STEPS SHALL BE COPOLYMER POLYPROPYLENE PLASTIC, REINFORCED WITH 1/2" GRADE 60 REINFORCEMENT OR SEWER DISTRICT APPROVED (IF ALLOWED BY LOCAL AUTHORITY). 24. ALL SANITARY SEWER LINES SHALL BE AIR TESTED AND MUST CONFORM TO ASTM C828, LATEST REVISION. 25. ALL FLEXIBLE AND SEMI-RIGID PIPE SHALL BE TESTED BY PULLING A MANDREL, GO/NO GO, DEVICE BY HAND NO EARLIER THAN 30 DAYS AFTER THE TRENCHING HAS BEEN COMPLETELY BACKFILLED. THE MAXIMUM ALLOWABLE DEFLECTION SHALL NOT EXCEED 5 PERCENT OF NOMINAL INSIDE DIAMETER. 26. CONTRACTOR SHALL NOT TIE NEW SEWER LINE TO EXISTING MANHOLE UNTIL ALL CONSTRUCTION IS APPROVED, TESTED AND ACCEPTED BY THE LOCAL GOVERNING AUTHORITY. 27. A PRE-CONSTRUCTION CONFERENCE WITH THE CONTRACTOR, SEWER AUTHORITY, STATE HEALTH AUTHORITY, AND THE ENGINEER WILL BE HELD PRIOR TO SEWER LINE CONSTRUCTION. CONTRACTOR SHALL SET UP PRE-CONSTRUCTION CONFERENCE WITH CITY. 28. THE CONTRACTOR SHALL GRASS ALL RIGHT-OF-WAY IN ACCORDANCE WITH SPECIFICATIONS FOR GRASSING. 29. ALL SEWER LINE WORK SHALL BE "APPROVED" BY THE STATE HEALTH AND LOCAL AUTHORITY, AND "APPROVED" AS-BUILT DRAWINGS SHALL BE FURNISH TO THE OWNER BEFORE CONTRACTOR RECEIVES FINAL PAYMENT. 30. THE CONTRACTOR SHALL NOT PERFORM ANY WORK UNTIL HE HAS OBTAINED COPIES OF ALL NECESSARY ENCROACHMENT AND CONSTRUCTION PERMITS. SCDES 1. IF NECESSARY, SLOPES, WHICH EXCEED EIGHT (8) VERTICAL FEET SHOULD BE STABILIZED WITH SYNTHETIC OR VEGETATIVE MATS, IN ADDITION TO HYDROSEEDING. IT MAY BE NECESSARY TO INSTALL TEMPORARY SLOPE DRAINS DURING CONSTRUCTION. TEMPORARY BERMS MAY BE NEEDED UNTIL THE SLOPE IS BROUGHT TO GRADE. 2. STABILIZATION MEASURES SHALL BE INITIATED AS SOON AS PRACTICABLE IN PORTIONS OF THE SITE WHERE CONSTRUCTION ACTIVITIES HAVE TEMPORARILY OR PERMANENTLY CEASED, BUT IN NO CASE MORE THAN FOURTEEN (14) DAYS AFTER WORK HAS CEASED, EXCEPT AS STATED BELOW. ·WHERE STABILIZATION BY THE 14TH DAY IS PRECLUDED BY SNOW COVER OR FROZEN GROUND CONDITIONS STABILIZATION MEASURES MUST BE INITIATED AS SOON AS PRACTICABLE. ·WHERE CONSTRUCTION ACTIVITY ON A PORTION OF THE SITE IS TEMPORARILY CEASED, AND EARTH-DISTURBING ACTIVITIES WILL BE RESUMED WITHIN 14 DAYS, TEMPORARY STABILIZATION MEASURES DO NOT HAVE TO BE INITIATED ON THAT PORTION OF THE SITE. 3. ALL SEDIMENT AND EROSION CONTROL DEVICES SHALL BE INSPECTED ONCE EVERY CALENDAR WEEK. IF PERIODIC INSPECTION OR OTHER INFORMATION INDICATES THAT A BMP HAS BEEN INAPPROPRIATELY, OR INCORRECTLY, THE PERMITTEE MUST ADDRESS THE NECESSARY REPLACEMENT OR MODIFICATION REQUIRED TO CORRECT THE BMP WITHIN 48 HOURS OF IDENTIFICATION. 4. PROVIDE SILT FENCE AND/OR OTHER CONTROL DEVICES, AS MAY BE REQUIRED, TO CONTROL SOIL EROSION DURING UTILITY CONSTRUCTION. ALL DISTURBED AREAS SHALL BE CLEANED, GRADED, AND STABILIZED WITH GRASSING IMMEDIATELY AFTER THE UTILITY INSTALLATION. FILL, COVER, AND TEMPORARY SEEDING AT THE END OF EACH DAY ARE RECOMMENDED. IF WATER IS ENCOUNTERED WHILE TRENCHING, THE WATER SHOULD BE FILTERED TO REMOVE SEDIMENT BEFORE BEING PUMPED BACK INTO ANY WATERS OF THE STATE. 5. ALL EROSION CONTROL DEVICES SHALL BE PROPERLY MAINTAINED DURING ALL PHASES OF CONSTRUCTION UNTIL THE COMPLETION OF ALL CONSTRUCTION ACTIVITIES AND ALL DISTURBED AREAS HAVE BEEN STABILIZED. ADDITIONAL CONTROL DEVICES MAY BE REQUIRED DURING CONSTRUCTION IN ORDER TO CONTROL EROSION AND/OR OFFSITE SEDIMENTATION. ALL TEMPORARY CONTROL DEVICES SHALL BE REMOVED ONCE CONSTRUCTION IS COMPLETE AND THE SITE IS STABILIZED. 6. THE CONTRACTOR MUST TAKE NECESSARY ACTION TO MINIMIZE THE TRACKING OF MUD ONTO PAVED ROADWAY(S) FROM CONSTRUCTION AREAS AND THE GENERATION OF DUST. THE CONTRACTOR SHALL DAILY REMOVE MUD/SOIL FROM PAVEMENT, AS MAY BE REQUIRED. 7. RESIDENTIAL SUBDIVISIONS REQUIRE EROSION CONTROL FEATURES FOR INFRASTRUCTURE AS WELL AS FOR INDIVIDUAL LOT CONSTRUCTION. INDIVIDUAL PROPERTY OWNERS SHALL FOLLOW THESE PLANS DURING CONSTRUCTION OR OBTAIN APPROVAL OF AN INDIVIDUAL PLAN IN ACCORDANCE WITH S.C REG. 72-300 ET SEQ. AND SCR100000. 8. TEMPORARY DIVERSION BERMS AND/OR DITCHES WILL BE PROVIDED AS NEEDED DURING CONSTRUCTION TO PROTECT WORK AREAS FROM UPSLOPE RUNOFF AND/OR TO DIVERT SEDIMENT-LADEN WATER TO APPROPRIATE TRAPS OR STABLE OUTLETS. 9. ALL WATERS OF THE STATE (WOS), INCLUDING WETLANDS, ARE TO BE FLAGGED OR OTHERWISE CLEARLY MARKED IN THE FIELD. A DOUBLE ROW OF SILT FENCE IS TO BE INSTALLED IN ALL AREAS WHERE A 50-FOOT BUFFER CAN’T BE MAINTAINED BETWEEN THE DISTURBED AREA AND ALL WOS. A 10-FOOT BUFFER SHOULD BE MAINTAINED BETWEEN THE LAST ROW OF SILT FENCE AND ALL WOS.. 10. LITTER, CONSTRUCTION DEBRIS, OILS, FUELS, AND BUILDING PRODUCTS WITH SIGNIFICANT POTENTIAL FOR IMPACT (SUCH AS STOCKPILES OF FRESHLY TREATED LUMBER) AND CONSTRUCTION CHEMICALS THAT COULD BE EXPOSED TO STORM WATER MUST BE PREVENTED FROM BECOMING A POLLUTANT SOURCE IN STORM WATER DISCHARGES. 11. A COPY OF THE SWPPP, INSPECTIONS RECORDS, AND RAINFALL DATA MUST BE RETAINED AT THE CONSTRUCTION SITE OR A NEARBY LOCATION EASILY ACCESSIBLE DURING NORMAL BUSINESS HOURS, FROM THE DATE OF COMMENCEMENT OF CONSTRUCTION ACTIVITIES TO THE DATE THAT FINAL STABILIZATION IS REACHED. 12. INITIATE STABILIZATION MEASURES ON ANY EXPOSED STEEP SLOPE (3H:1V OR GREATER) WHERE LAND-DISTURBING ACTIVITIES HAVE PERMANENTLY OR TEMPORARILY CEASED, AND WILL NOT RESUME FOR A PERIOD OF 7 CALENDAR DAYS. 13. MINIMIZE SOIL COMPACTION AND, UNLESS INFEASIBLE, PRESERVE TOPSOIL. 14. MINIMIZE THE DISCHARGE OF POLLUTANTS FROM EQUIPMENT AND VEHICLE WASHING, WHEEL WASH WATER, AND OTHER WASH WATERS. WASH WATERS MUST BE TREATED IN A SEDIMENT BASIN OR ALTERNATIVE CONTROL THAT PROVIDES EQUIVALENT OR BETTER TREATMENT PRIOR TO DISCHARGE; 15. MINIMIZE THE DISCHARGE OF POLLUTANTS FROM DEWATERING OF TRENCHES AND EXCAVATED AREAS. THESE DISCHARGES ARE TO BE ROUTED THROUGH APPROPRIATE BMPS (SEDIMENT BASIN, FILTER BAG, ETC.). 16. THE FOLLOWING DISCHARGES FROM SITES ARE PROHIBITED ·WASTEWATER FROM WASHOUT OF CONCRETE, UNLESS MANAGED BY AN APPROPRIATE CONTROL; ·WASTEWATER FROM WASHOUT AND CLEANOUT OF STUCCO, PAINT, FORM RELEASE OILS, CURING COMPOUNDS AND OTHER CONSTRUCTION MATERIALS; ·FUELS, OILS, OR OTHER POLLUTANTS USED IN VEHICLE AND EQUIPMENT OPERATION AND MAINTENANCE; AND ·SOAPS OR SOLVENTS USED IN VEHICLE AND EQUIPMENT WASHING. 17. AFTER CONSTRUCTION ACTIVITIES BEGIN, INSPECTIONS MUST BE CONDUCTED AT A MINIMUM OF AT LEAST ONCE EVERY CALENDAR WEEK AND MUST BE CONDUCTED UNTIL FINAL STABILIZATION IS REACHED ON ALL AREAS OF THE CONSTRUCTION SITE. 18. IF EXISTING BMPS NEED TO BE MODIFIED OR IF ADDITIONAL BMPS ARE NECESSARY TO COMPLY WITH THE REQUIREMENTS OF THIS PERMIT AND/OR SC’S WATER QUALITY STANDARDS, IMPLEMENTATION MUST BE COMPLETED BEFORE THE NEXT STORM EVENT WHENEVER PRACTICABLE. IF IMPLEMENTATION BEFORE THE NEXT STORM EVENT IS IMPRACTICABLE, THE SITUATION MUST BE DOCUMENTED IN THE SWPPP AND ALTERNATIVE BMPS MUST BE IMPLEMENTED AS SOON AS REASONABLY POSSIBLE. 19. A PRE-CONSTRUCTION CONFERENCE MUST BE HELD FOR EACH CONSTRUCTION SITE WITH AN APPROVED ON-SITE SWPPP PRIOR TO THE IMPLEMENTATION OF CONSTRUCTION ACTIVITIES. FOR NON-LINEAR PROJECTS THAT DISTURB 10 ACRES OR MORE THIS CONFERENCE MUST BE HELD ON-SITE UNLESS THE DEPARTMENT HAS APPROVED OTHERWISE. MISCELLANEOUS 1. ALL RIP RAP FOR CHECK DAMS, EMERGENCY SPILLWAYS, AND OUTLET STABILIZATION PROTECTION TO BE UNDERLAIN WITH FILTER FABRIC. ALL RIP-RAP SHALL BE DUMPED RIP-RAP IN ACCORDANCE WITH THE SOUTH CAROLINA STATE HIGHWAY DEPARTMENT STANDARD SPECIFICATIONS FOR HIGHWAY CONSTRUCTION, LATEST EDITION. PIECES SHALL BE NO LARGER THAN 24 INCHES. 2. ASPHALT DESIGN SHALL BE DONE BY GEOTECHICAL ENGINEER. CONTRACTOR TO COORDINATE WITH OWNER FOR ASPHALT SPECIFICATION. 3. THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL PERMITS HIS REQUIRED FOR BORROW AREA (IF NEEDED). 4. ALL EROSION CONTROL FOR STOCKPILING OF DIRT SHALL COMPLY WITH SCDES STANDARDS. 5. SEDIMENT MUST BE REMOVED FROM SEDIMENT CONTROL DIKE WHEN SEDIMENT REACHES 50% OF THE SEDIMENT STORAGE VOLUME OR THE TOP OF THE CLEAN-OUT STAKE, WHICHEVER IS LESS. 6. ALL SLOPES DRAINING OFF-SITE, (NOT THROUGH POND) TO BE GRASSED AND STABILIZED WITH EROSION CONTROL BLANKETS. ABBREVIATIONS ±MORE OR LESS ØDIAMETER AASHTO AMERICAN ASSOCIATION OF STATE HIGHWAY TRANSPORTATION OFFICIALS Ac.ACRE ADAAMERICANS WITH DISABILITY ACT ANSI AMERICAN NATIONAL STANDARDS INSTITUTE ASTM AMERICAN SOCIETY OF TESTING AND MATERIALS AWWA AMERICAN WATER WORKS ASSOCIATION BMBENCHMARK BMPEROSION CONTROL BEST MANAGEMENT PRACTICES BOW BOTTOM OF WALL C&GCURB AND GUTTER CBCATCH BASIN CIPCAST IN PLACE CLCENTERLINE CYCUBIC YARD DBHDIAMETER BREAST HEIGHT DESDEPARTMENT OF ENVIRONMENTAL SERVICES DIPDUCTILE IRON PIPE EEAST E.G.EXAMPLE GIVEN ELELEVATION ETCETCETERA FDCFIRE DEPARTMENT CONNECTION FFEFINISHED FLOOR ELEVATION FHWA FEDERAL HIGHWAY ADMINISTRATION FIRM FLOOD INSURANCE RATE MAP FPEFINISHED PAD ELEVATION FTFEET (LENGTH) HHORIZONTAL HDPE HIGH-DENSITY POLYETHYLENE HPHIGH POINT IBCINTERNATIONAL BUILDING CODE IEINVERT ELEVATION INVINVERT LBSPOUNDS LFLINEAR FEET (LENGTH) LPLOW POINT MAXMAXIMUM MINMINIMUM MPCE MATCH PRE-CONSTRUCTION ELEVATION MS4s STORMWATER DISCHARGE FROM MUNICIPAL SEPARATE STORM SEWER SYSTEMS MUTCD MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES NNORTH NENORTHEAST NO.NUMBER NSFNATIONAL SANITATION FOUNDATION NTSNOT TO SCALE NWNORTHWEST OCON CENTER OSHA OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION PCPRECAST PVCPOLYVINYLCHLORIDE RRADIUS RCPREINFORCED CONCRETE PIPE R/WRIGHT OF WAY PSFPOUNDS PER SQUARE FOOT (PRESSURE) PSIPOUNDS PER SQUARE INCH (PRESSURE) PSIGPOUNDS PER SQUARE INCH GUAGE SSOUTH SCDES SOUTH CAROLINA DEPARTMENT OF ENVIRONMENTAL SERVICES SCDOT SOUTH CAROLINA DEPARTMENT OF TRANSPORATION SESOUTHEAST SFSQUARE FEET STASTATION STD. STANDARD SWSOUTHWEST TCTOP OF CURB TPTOP OF PAVEMENT TOW TOP OF WALL TYPTYPICAL VVERTICAL VCPVITRIFIED CLAY PIPE WWEST WWF WELDED WIRE FABRIC THERE MAY BE ADDITIONAL ABBREVIATIONS USED IN THESE PLANS. PLEASE CONTACT ENGINEER IF ANY ABBREVIATION IS UNDEFINED OR UNCLEAR. OVERHEAD CABLE XOC LEGEND G XGGAS OC DIVERSION BERM DB DIVERSION DITCH DD OVERHEAD ELECTRIC XOEOE OVERHEAD TELEPHONE XOTOT PERMANENT DIVERSION DITCHPD ROOF DRAIN RD RSFREINFORCED SILT FENCE STORM DRAINAGE XDSD SANITARY SEWER XSSS SSDSUBSURFACE DRAIN TEMPORARY DIVERSION DITCHTD TREE PROTECTION TP C XCUNDERGROUND COMMUNICATION E XEUNDERGROUND ELECTRIC W XWWATER FIRE SERVICE FW X XXFENCE THERE MAY BE ADDITIONAL SYMBOLS USED IN THESE PLANS. PLEASE CONTACT ENGINEER IF ANY SYMBOL IS UNDEFINED OR UNCLEAR. EXISTINGPROPOSEDDESCRIPTION FIRE HYDRANT SEWER CLEANOUT ELECTRICAL BOX UTILITY POLE WATER VALVE LIGHT POLE WATER METER CABLE BOX TELEPHONE BOX BENCHMARK POST INDICATOR VALVE IRON PIN SIGN REDUCER TELEPHONE MANHOLE ELECTRICAL MANHOLE PARKING COUNT FIRE DEPARTMENT CONNECTION ASPHALT PAVEMENT (LIGHT DUTY) CONCRETE PAVEMENT BRICK PAVEMENT OR HARDSCAPE WETLANDS PROPERTY BOUNDARY ADJACENT/INTERNAL PROPERTY LINES BUFFER WETLANDS CENTERLINE GRAVEL PAVEMENT LIMITS OF DISTURBANCE UTILITY LINE, PIPE, OR CURB TO BE DEMOLISHED ASPHALT PAVEMENT (HEAVY DUTY) SANITARY SEWER MANHOLE STORM DRAINAGE - CATCH BASIN TYPE 16 STORM DRAINAGE - CATCH BASIN TYPE 9 STORM DRAINAGE - CURB INLET TYPE 1 STORM DRAINAGE - DROP INLET STORM DRAINAGE - JUNCTION BOX INLET PROTECTION TYPE A INLET PROTECTION TYPE F INLET PROTECTION TYPE E ROCK OUTLET STABILIZATION ROCK SEDIMENT DIKE STORM DRAINAGE - MISCELLANEOUS TREE - TO BE REMOVED TREE EASEMENT SETBACK ENTITY TO BE DEMOLISHED HOSE PULL HP ROCK CHECK DAM SILTSACK INLET PROTECTION CONCRETE WASHOUT SILT FENCE SF TREE - TO BE RELOCATED PARKING ISLAND GUTTER EEL INLET PROTECTION TREE PROTECTION BARRICADETB or or or or or TURBIDITY BARRIER 22 6121)4#2*+%5748'; +5.'1(2#./5/#4+0# %*#4.'5610%1706;5176*%#41.+0# ,./ 5*''607/$'4 241,'%607/$'4 &4#90%*'%-'& &4#9+0)(+.'0#/' &#6'5748';'& 1( ENVIRONMENTAL ENGINEERING SURVEYING Engineering LLC a member of THE GEL GROUP problem solved P.O. BOX 30712 Charleston, SC 29417 2040 Savage Road Charleston, SC 29407 P 843.769.7378 F 843.769.7397 www.gel.com 018'/$'4 ,./ #6/#   #22418'&2.166'& ($  .#564'8+5'&  .+0'.')'0& GRAPHIC SCALE #$$4'8+#6+105 +1227/256#6+10 %106174+06'48#.ž SITE CONDITIONS V-1 SHEET NUMBER SITE CONDITION DATA PROVIDED TO CLINE ENGINEERING BY OTHERS. CONTRACTOR TO VERIFY PRIOR TO CONSTRUCTION. 23 XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XE XE XE XE XS XS XS XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XEXE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XSXSXSXSXSXSXSXSXSXSXSXSXSXSXSXS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XD XD XD XD XD XD XD XD XD XD XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XCXCXCXCXCXCXCXCXCXCXCXC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X ADA ACCESSIBLE PATH ADA ACCESSIBLE PATH PLOT DATE: 7/29/2026 10:54:21 AM FILE LOCATION: X:\2022\22047.ACAD\001\X\PRODUCTION.DRAWINGS\PD.0025 C L I N E E N G I N E E R I N G THIS DRAWING AND ASSOCIATED CAD FILES ARE AN INSTRUMENT OF SERVICE AND THE PROPERTY OF CLINE ENGINEERING, INC. AND SHALL NOT BE USED OR REPRODUCED IN ANY WAY OTHER THAN AUTHORIZED BY CLINE ENGINEERING, INC. IN WRITING. REV. DATE DRAWN APPV.DESCRIPTION SHEET NUMBER PROJECT MANAGER DRAWN BY PROJECT DATE JOB NUMBER PROFESSIONAL DESIGN CONSULTING 50 41ST AVENUE ISLE OF PALMS, SOUTH CAROLINA IOP MASTER PLAN 22047 AUGUST 2022 AJ/JR MDC A 07/29/2026 ISSUED FOR REVIEW AND APPROVAL -- MDC SITE PLAN C-1 N 53 27.9 Max 68.5° Horiz Max 10° Vert 43.542.5 23.5 417.44.2 WB-67 - Interstate Semi-Trailer Overall Length73.501ft Overall Width8.500ft Overall Body Height13.500ft Min Body Ground Clearance1.334ft Max Track Width8.500ft Lock-to-lock time6.00s Max Steering Angle (Virtual)28.40° VEHICLE TRACKING SPECIFICATIONS SAFETY NOTE TO CONTRACTOR THE CONTRACTOR SHALL SHORE TRENCH EXCAVATION AND USE PIPE BOX TO COMPLY WITH ALL OSHA SAFETY REGULATIONS. IT IS THE CONTRACTOR'S SOLE RESPONSIBILITY TO PROVIDE JOB SITE SAFETY AND COMPLY WITH ALL SAFETY REQUIREMENTS. THE CONTRACTOR IS RESPONSIBLE FOR HIS MEANS AND METHODS OF CONSTRUCTION. UTILITY NOTE TO CONTRACTOR THE UTILITIES SHOWN ARE FOR THE CONTRACTOR'S CONVENIENCE ONLY. THERE MAY BE OTHER UTILITIES NOT SHOWN ON THESE PLANS. THE ENGINEER ASSUMES NO RESPONSIBILITY FOR THE LOCATIONS SHOWN AND IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE LOCATIONS OF ALL UTILITIES WITHIN THE LIMITS OF THE WORK. ALL DAMAGE MADE TO EXISTING UTILITIES BY THE CONTRACTOR SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR. SITE DATA TABLE TAX MAP INFORMATION TMS # 571-08-00-007 SUBJECT PARCEL(S) ZONINGGENERAL COMMERCIAL DISTRICT (GC1) SUBJECT PARCEL(S) AREA5.12 Ac.± BUILDING AREA - PROPOSEDNONE BUILDING SETBACK REQUIREMENTS N/A SITE BUFFER REQUIREMENTS 15' BUFFER YARD ABUTTING RESIDENTIAL PROPERTY BUILDING HEIGHT LIMITSN/A FLOOD ZONE INFORMATION (PROVIDED BY OTHERS) PROJECT SITE APPEARS TO BE LOCATED IN FLOOD ZONE "AE (11 & 12)" AS SCALED FROM FIRM COMMUNITY PANEL NUMBER 455416 AND MAP NUMBER 45019C0542K DATED JANUARY 29, 2021. THE DEPICTION OF THE FLOOD ZONE WITHIN THIS SET OF PLANS SHALL NOT BE USED AS THE BASIS FOR FLOOD ZONE DETERMINATION OR FLOOD ZONE RELATED ISSUES. 24 XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XE XE XE XE XS XS XS XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XEXE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XSXSXSXSXSXSXSXSXSXSXSXSXSXSXSXS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XD XD XD XD XD XD XD XD XD XD XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XCXCXCXCXCXCXCXCXCXCXCXC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SFSFSFSF PLOT DATE: 7/29/2026 10:54:43 AM FILE LOCATION: X:\2022\22047.ACAD\001\X\PRODUCTION.DRAWINGS\PD.0031 C L I N E E N G I N E E R I N G THIS DRAWING AND ASSOCIATED CAD FILES ARE AN INSTRUMENT OF SERVICE AND THE PROPERTY OF CLINE ENGINEERING, INC. AND SHALL NOT BE USED OR REPRODUCED IN ANY WAY OTHER THAN AUTHORIZED BY CLINE ENGINEERING, INC. IN WRITING. REV. DATE DRAWN APPV.DESCRIPTION SHEET NUMBER PROJECT MANAGER DRAWN BY PROJECT DATE JOB NUMBER PROFESSIONAL DESIGN CONSULTING 50 41ST AVENUE ISLE OF PALMS, SOUTH CAROLINA IOP MASTER PLAN 22047 AUGUST 2022 AJ/JR MDC A 07/29/2026 ISSUED FOR REVIEW AND APPROVAL -- MDC C-2 DEMOLITION AND SWPPP N SAFETY NOTE TO CONTRACTOR THE CONTRACTOR SHALL SHORE TRENCH EXCAVATION AND USE PIPE BOX TO COMPLY WITH ALL OSHA SAFETY REGULATIONS. IT IS THE CONTRACTOR'S SOLE RESPONSIBILITY TO PROVIDE JOB SITE SAFETY AND COMPLY WITH ALL SAFETY REQUIREMENTS. THE CONTRACTOR IS RESPONSIBLE FOR HIS MEANS AND METHODS OF CONSTRUCTION. UTILITY NOTE TO CONTRACTOR THE UTILITIES SHOWN ARE FOR THE CONTRACTOR'S CONVENIENCE ONLY. THERE MAY BE OTHER UTILITIES NOT SHOWN ON THESE PLANS. THE ENGINEER ASSUMES NO RESPONSIBILITY FOR THE LOCATIONS SHOWN AND IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE LOCATIONS OF ALL UTILITIES WITHIN THE LIMITS OF THE WORK. ALL DAMAGE MADE TO EXISTING UTILITIES BY THE CONTRACTOR SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR. 25 XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XE XE XE XE XS XS XS XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XEXE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XSXSXSXSXSXSXSXSXSXSXSXSXSXSXSXS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XD XD XD XD XD XD XD XD XD XD XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XCXCXCXCXCXCXCXCXCXCXCXC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SFSFSFSF PLOT DATE: 7/29/2026 10:55:06 AM FILE LOCATION: X:\2022\22047.ACAD\001\X\PRODUCTION.DRAWINGS\PD.0032 C L I N E E N G I N E E R I N G THIS DRAWING AND ASSOCIATED CAD FILES ARE AN INSTRUMENT OF SERVICE AND THE PROPERTY OF CLINE ENGINEERING, INC. AND SHALL NOT BE USED OR REPRODUCED IN ANY WAY OTHER THAN AUTHORIZED BY CLINE ENGINEERING, INC. IN WRITING. REV. DATE DRAWN APPV.DESCRIPTION SHEET NUMBER PROJECT MANAGER DRAWN BY PROJECT DATE JOB NUMBER PROFESSIONAL DESIGN CONSULTING 50 41ST AVENUE ISLE OF PALMS, SOUTH CAROLINA IOP MASTER PLAN 22047 AUGUST 2022 AJ/JR MDC A 07/29/2026 ISSUED FOR REVIEW AND APPROVAL -- MDC C-3 GRADING AND DRAINAGE PLAN N SAFETY NOTE TO CONTRACTOR THE CONTRACTOR SHALL SHORE TRENCH EXCAVATION AND USE PIPE BOX TO COMPLY WITH ALL OSHA SAFETY REGULATIONS. IT IS THE CONTRACTOR'S SOLE RESPONSIBILITY TO PROVIDE JOB SITE SAFETY AND COMPLY WITH ALL SAFETY REQUIREMENTS. THE CONTRACTOR IS RESPONSIBLE FOR HIS MEANS AND METHODS OF CONSTRUCTION. UTILITY NOTE TO CONTRACTOR THE UTILITIES SHOWN ARE FOR THE CONTRACTOR'S CONVENIENCE ONLY. THERE MAY BE OTHER UTILITIES NOT SHOWN ON THESE PLANS. THE ENGINEER ASSUMES NO RESPONSIBILITY FOR THE LOCATIONS SHOWN AND IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE LOCATIONS OF ALL UTILITIES WITHIN THE LIMITS OF THE WORK. ALL DAMAGE MADE TO EXISTING UTILITIES BY THE CONTRACTOR SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR. 26 XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XD XE XE XE XE XS XS XS XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XEXE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XE XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XSXSXSXSXSXSXSXSXSXSXSXSXSXSXSXS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XS XD XD XD XD XD XD XD XD XD XD XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XCXCXCXCXCXCXCXCXCXCXCXC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC XC X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SFSFSFSF PLOT DATE: 7/29/2026 10:55:26 AM FILE LOCATION: X:\2022\22047.ACAD\001\X\PRODUCTION.DRAWINGS\PD.0033 C L I N E E N G I N E E R I N G THIS DRAWING AND ASSOCIATED CAD FILES ARE AN INSTRUMENT OF SERVICE AND THE PROPERTY OF CLINE ENGINEERING, INC. AND SHALL NOT BE USED OR REPRODUCED IN ANY WAY OTHER THAN AUTHORIZED BY CLINE ENGINEERING, INC. IN WRITING. REV. DATE DRAWN APPV.DESCRIPTION SHEET NUMBER PROJECT MANAGER DRAWN BY PROJECT DATE JOB NUMBER PROFESSIONAL DESIGN CONSULTING 50 41ST AVENUE ISLE OF PALMS, SOUTH CAROLINA IOP MASTER PLAN 22047 AUGUST 2022 AJ/JR MDC A 07/29/2026 ISSUED FOR REVIEW AND APPROVAL -- MDC C-4 UTILITY PLAN N SAFETY NOTE TO CONTRACTOR THE CONTRACTOR SHALL SHORE TRENCH EXCAVATION AND USE PIPE BOX TO COMPLY WITH ALL OSHA SAFETY REGULATIONS. IT IS THE CONTRACTOR'S SOLE RESPONSIBILITY TO PROVIDE JOB SITE SAFETY AND COMPLY WITH ALL SAFETY REQUIREMENTS. THE CONTRACTOR IS RESPONSIBLE FOR HIS MEANS AND METHODS OF CONSTRUCTION. UTILITY NOTE TO CONTRACTOR THE UTILITIES SHOWN ARE FOR THE CONTRACTOR'S CONVENIENCE ONLY. THERE MAY BE OTHER UTILITIES NOT SHOWN ON THESE PLANS. THE ENGINEER ASSUMES NO RESPONSIBILITY FOR THE LOCATIONS SHOWN AND IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE LOCATIONS OF ALL UTILITIES WITHIN THE LIMITS OF THE WORK. ALL DAMAGE MADE TO EXISTING UTILITIES BY THE CONTRACTOR SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR. NO UTILITY IMPROVEMENTS PROPOSED 27 PLOT DATE: 7/29/2026 10:55:35 AM FILE LOCATION: X:\2022\22047.ACAD\001\X\PRODUCTION.DRAWINGS\PD.0034 C L I N E E N G I N E E R I N G THIS DRAWING AND ASSOCIATED CAD FILES ARE AN INSTRUMENT OF SERVICE AND THE PROPERTY OF CLINE ENGINEERING, INC. AND SHALL NOT BE USED OR REPRODUCED IN ANY WAY OTHER THAN AUTHORIZED BY CLINE ENGINEERING, INC. IN WRITING. REV. DATE DRAWN APPV.DESCRIPTION SHEET NUMBER PROJECT MANAGER DRAWN BY PROJECT DATE JOB NUMBER PROFESSIONAL DESIGN CONSULTING 50 41ST AVENUE ISLE OF PALMS, SOUTH CAROLINA IOP MASTER PLAN 22047 AUGUST 2022 AJ/JR MDC A 07/29/2026 ISSUED FOR REVIEW AND APPROVAL -- MDC C-5 CONSTRUCTION DETAILS CONSTRUCTION ENTRANCE South Carolina Department of Health and Environmental Control SIZE SPECIFICATION PLAN SYMBOL DATE South Carolina Department of Health and Environmental Control CONSTRUCTION ENTRANCE DATE FLAT-BOTTOM TRENCH DETAIL V-SHAPED TRENCH DETAIL SILT FENCE INSTALLATION South Carolina Department of Health and Environmental Control PLAN SYMBOL DATE STANDARD DRAWING NO. South Carolina Department of Health and Environmental Control DATE SILTSACK INLET PROTECTION DETAIL NOT TO SCALE · · · 28 PLOT DATE: 7/29/2026 10:55:38 AM FILE LOCATION: X:\2022\22047.ACAD\001\X\PRODUCTION.DRAWINGS\PD.0034 C L I N E E N G I N E E R I N G THIS DRAWING AND ASSOCIATED CAD FILES ARE AN INSTRUMENT OF SERVICE AND THE PROPERTY OF CLINE ENGINEERING, INC. AND SHALL NOT BE USED OR REPRODUCED IN ANY WAY OTHER THAN AUTHORIZED BY CLINE ENGINEERING, INC. IN WRITING. REV. DATE DRAWN APPV.DESCRIPTION SHEET NUMBER PROJECT MANAGER DRAWN BY PROJECT DATE JOB NUMBER PROFESSIONAL DESIGN CONSULTING 50 41ST AVENUE ISLE OF PALMS, SOUTH CAROLINA IOP MASTER PLAN 22047 AUGUST 2022 AJ/JR MDC A 07/29/2026 ISSUED FOR REVIEW AND APPROVAL -- MDC C-6 CONSTRUCTION DETAILS TYPICAL PARKING SPACE DETAIL NOT TO SCALE TYPICAL ADA PARKING STRIPING DETAIL NOT TO SCALE INTERNATIONAL ADA SYMBOL DETAIL NOT TO SCALE ADA PARKING SIGN DETAIL NOT TO SCALE DO NOT ENTER SIGN DETAIL NOT TO SCALE ENTER DO NOT CHAIN LINK FENCE AND GATE DETAIL NOT TO SCALE CONCRETE SIDEWALK DETAIL NOT TO SCALE SECTIONASECTIONBTYPICAL THICKENED EDGE AT PARKING LOT HEAVY DUTY ASPHALT PAVEMENT NOT TO SCALE 29 PLOT DATE: 7/29/2026 10:55:39 AM FILE LOCATION: X:\2022\22047.ACAD\001\X\PRODUCTION.DRAWINGS\PD.0034 C L I N E E N G I N E E R I N G THIS DRAWING AND ASSOCIATED CAD FILES ARE AN INSTRUMENT OF SERVICE AND THE PROPERTY OF CLINE ENGINEERING, INC. AND SHALL NOT BE USED OR REPRODUCED IN ANY WAY OTHER THAN AUTHORIZED BY CLINE ENGINEERING, INC. IN WRITING. REV. DATE DRAWN APPV.DESCRIPTION SHEET NUMBER PROJECT MANAGER DRAWN BY PROJECT DATE JOB NUMBER PROFESSIONAL DESIGN CONSULTING 50 41ST AVENUE ISLE OF PALMS, SOUTH CAROLINA IOP MASTER PLAN 22047 AUGUST 2022 AJ/JR MDC A 07/29/2026 ISSUED FOR REVIEW AND APPROVAL -- MDC C-7 CONSTRUCTION DETAILS 30 - CODE OF ORDINANCES Title 3 PUBLIC WORKS Isle of Palms, South Carolina, Code of Ordinances Created: 2026-01-06 12:52:59 [EST] (Supp. No. 27) Page 1 of 42 Title 3 PUBLIC WORKS CHAPTER 1. STREETS AND SIDEWALKS1 ARTICLE A. GENERAL PROVISIONS Sec. 3-1-1. Obstruction—Consent required. It shall be unlawful for any person to obstruct, cause to be obstructed, or permit the obstruction by any means or in any manner and to any extent any public sidewalk, footway, bicycle path, public street or highway, public square, alley or other public place or grounds within the City for any purpose without the consent of the City. (Code 1994, § 3-1-1) Sec. 3-1-2. Same—Removal required within time fixed or required. It shall be unlawful for any person to refuse or fail to remove or cause to be removed any obstruction on any street, highway or other public place within the time for which the City may have given its permission for the obstruction thereof; or if no time is set when permission is given, the obstruction shall be removed within such time as the City may require. (Code 1994, § 3-1-2) Sec. 3-1-3. Same—Permanent obstruction prohibited. No permission shall be granted for the placing of a permanent obstruction on any of the streets, highways or other public places in the City. (Code 1994, § 3-1-3) Sec. 3-1-4. Building materials in streets, sidewalks and public places—Permission required. BD Building materials shall not be laid on any sidewalk, street or public place until the consent of the Director of Public Works Building inspectorOfficial is first obtained; and it shall be the duty of the person desiring to use the streets to inform the Building inspectorOfficial Director when permission is desired to lay material thereon, and otherwise to obstruct the places for the purpose of erecting a building adjoining the street, where some obstruction thereof is necessary, what space will be needed and for what length of time the obstruction will be 1State law reference(s)—Streets and sidewalks, S.C. Code 1976, § 5-7-10 et seq.; issuance of permits to charitable groups to solicit funds from motorists, S.C. Code 1976, § 5-27-910; municipality may establish a farm marketing center, S.C. Code 1976, § 46-19-110; municipal authority to regulate processions on highways, S.C. Code 1976, § 56-5-710(3). 31 Created: 2026-01-06 12:52:57 [EST] (Supp. No. 27) Page 2 of 42 necessary; and the Director building inspector shall then give permission accordingly, imposing then and from time to time the reasonable conditions as the Director building inspector may consider necessary or proper for the protection of the public and the public property. (Code 1994, § 3-1-4) Sec. 3-1-5. Same—Protection by barricades, lights. While the obstructions provided for herein remain on the streets, sidewalks or other public places, suitable safeguards by day and by night shall be maintained by the contractor, owner or person in charge of the work, for the protection of the public, by roping off and using lanterns and other proper means. (Code 1994, § 3-1-5) Sec. 3-1-6. Same—Removal of conditions. BD At the expiration of the time provided for herein, all obstructions, materials and trash or other things shall be removed by the owner or contractor, and the street, sidewalk or public place shall be restored to as good condition in every respect as before the materials or other obstructions are laid thereon. (Code 1994, § 3-1-6) Sec. 3-1-7. Removal of glass, etc., left by wrecked vehicle. Any person removing a wrecked or damaged vehicle from a highway shall remove any glass or other injurious substance dropped upon the highway from the vehicle. (Code 1970, § 20-2; Code 1994, § 3-1-7) Sec. 3-1-8. Draining of grease, oil, etc., upon street prohibited. It shall be unlawful for any person to drain, deposit or discharge grease, oil, gasoline, animal waste, washing machine wastewater or other deleterious substances upon any street, ditch or ground, or into the ocean or marsh. (Code 1970, § 20-3; Code 1994, § 3-1-8; Ord. No. 1991-5, 7-25-1991) Sec. 3-1-9. Putting glass, trash, oil, etc., on the street prohibited. No person shall throw or deposit upon any street any glass, bottles, glass, nails, tacks, wire, cans, paper, trash or any other substance. Any person who drops or permits to be dropped or thrown upon any highway any destructive or injurious material shall immediately remove the same or cause it to be removed. (Code 1970, § 20-4; Code 1994, § 3-1-9) Sec. 3-1-10. Picnics on streets, rights-of-way, etc., prohibited. Outings and picnics on the rights-of-way, streets, highways or roads within the City are expressly prohibited. (Code 1970, § 6-6; Code 1994, § 3-1-10) 32 Created: 2026-01-06 12:52:57 [EST] (Supp. No. 27) Page 3 of 42 Sec. 3-1-11. Dumping prohibited is prohibited in waterways and ditches. (a) No person shall throw or place any refuse, paper, trash, glass, nails, tacks, wire, bottles, cans, yard trash, concrete, earthen fill, garbage, containers or litter or other debris in any ditch, creek, stream, river, or retention basin that regularly or periodically carries surface water runoff. (b) Any person who deposits any of the above-referenced items in any ditch, creek, stream, river or retention basin that regularly or periodically carries surface water runoff shall remove such items or cause such items to be removed therefrom immediately. (c) A violation of the foregoing shall be punishable as provided in section 1-3-66. (d) If deposited debris is not removed by the violator, the City is authorized to enter onto and upon private property as necessary to effect removal of debris. (e) The City is authorized to enter onto and upon private property to perform routine maintenance of all ditches, streams, rivers, or retention basins so as to effect the removal of any debris deposited for which no individual bears responsibility. (Code 1994, § 3-1-11; Ord. No. 1993-24, 12-28-1993) Secs. 3-1-12—3-1-20. Reserved. ARTICLE B. EXCAVATIONS Sec. 3-1-21. Permit required. It shall be unlawful for any person to dig any ditch, excavation, hole or opening in any street, sidewalk or public place without the permission of the City or the appropriate State agency where such excavation is not on private property. Permission shall not be granted until the purpose for which it is to be made or dug shall be made known, and then the ditch, excavation, hole or opening shall be used for the purpose so declared and no other. (Code 1994, § 3-1-21) Sec. 3-1-22. Protection by barricades, lights. Every ditch, excavation, hole or opening in any street, sidewalk or public place, no matter for what purpose made, shall be securely and safely covered over with boards or other suitable material, or enclosed in a secure way as to prevent accidents to persons, animals and vehicles, both during the night and day, when the workmen are not engaged thereon; and during the night provide safety lighting lanterns shall be kept burning at these places as a signal of danger to all pedestrians and drivers. (Code 1994, § 3-1-22) Sec. 3-1-23. Restoration of surface. Every ditch, excavation, hole or opening in any street, sidewalk or public place, shall be as speedily filled as possible, and shall not be kept open longer than is absolutely necessary. The street, sidewalk or public place shall be restored to as good condition with as good materials as existed before the ditch, excavation, hole or opening was made. 33 - CODE OF ORDINANCES Title 3 - PUBLIC WORKS CHAPTER 2. SOLID WASTE Isle of Palms, South Carolina, Code of Ordinances Created: 2026-01-06 12:52:58 [EST] (Supp. No. 27) Page 10 of 42 CHAPTER 2. SOLID WASTE2 Sec. 3-2-1. Burning to be performed in incinerator, etc. FD No person shall burn or cause to be burned any rubbish, trash, leaves, tree limbs, shavings, chips, sawdust or other debris within the City unless such material is burned in an incinerator or suitable metal container and such burning complies with all applicable state, federal and local environmental and safety laws, rules and regulations. (Code 1970, § 18-1; Code 1994, § 3-2-1; Ord. No. 1997-16, § 1, 8-26-1997) Sec. 3-2-2. Hours of authorized burning. FD Burning shall be allowed only during daylight hours. (Code 1994, § 3-2-2; Ord. No. 1997-16, § 2, 8-26-1997) State law reference(s)—Regulations of department of health and environmental control concerning burning, R 61- 62.2. Sec. 3-2-3. Procedure for burning quantity exceeding incinerator capacity. FD Whenever the material to be disposed of as set forth in section 3-2-1 exceeds the quantity that can be accommodated by an incinerator or suitable metal container, written permission to burn the material shall be secured from the Chief of the Fire Department and the burning shall be done only under the direction of the Fire Department and during daylight hours. (Code 1970, § 18-3; Code 1994, § 3-2-3) Sec. 3-2-4. Garbage containers required. (a) Residential. It shall be the duty of every owner or other occupant of a residential dwelling to use either a 96 90-gallon or a 40-gallon plastic roll-out cart approved by the City. Each dwelling shall receive one (1) cart from the City at no cost to the user. Additional carts may be rented purchased by the user. Each dwelling owner shall be responsible for damage to the cart unless such damage is caused by City personnel or normal wear. All garbage shall be kept in the carts until collected by the City and shall be kept closed in such a manner as will prevent access by flies, rodents and other animals. The cart and contents shall not weigh more than two hundred (200) pounds. No garbage cart shall be used for any other purpose. In the event of overflow, plastic bags which are tightly bound may be placed on the carts at curbside on the day of collection. In the event of regular overflow, the Director of Public Works may require owners to purchase an additional roll cart(s). The owner or occupant of any dwelling where carts or plastic bags are placed at curbside shall be responsible for prompt cleanup and removal of the contents of such carts and bags if the 2State law reference(s)—Spilling loads on highways, S.C. Code 1976, § 56-5-4100; solid waste management; storage, transportation and collection of municipal solid wastes, S.C. Code Reg. 61-107.5; full cost disclosure by local governments concerning solid waste management, S.C. Code 1976, § 44-96-90. 34 Created: 2026-01-06 12:52:58 [EST] (Supp. No. 27) Page 11 of 42 bags are torn or the carts overturned from any cause. If a cart is damaged through negligence or abuse, it shall be the responsibility of the owner to replace the cart and the Public Works Department may refuse to handle such cart until it is replaced. Roll-out carts found to be inoperable due to normal wear or usage shall be repaired or replaced by the Public Works Department. The Public Works Department will notify users that a roll-out cart is unfit for continued use by placing a tag on the cart. All carts shall remain at the dwelling, and shall remain the property of the City. (b) Commercial. (1) Each business which generates a volume of garbage in excess of two (2) 90-gallon roll-out carts between scheduled collection dates of the Public Works Department may be required to use a bulk container of appropriate capacity approved by the Public Works Department if the site lacks sufficient area for safe and proper storage of the cart. (2) Bulk containers shall be of sufficient size to hold all garbage deposited between scheduled collection dates so that there shall be no spillage of garbage or other material from said container. (3) Bulk containers shall be placed in an area easily accessible to the equipment used for collection. Such area shall be designated for each container by the Public Works Department. (4) No container used for garbage shall be used for any other purpose. Garbage will be collected only if it is deposited in an approved container at a location also approved by the Public Works Department. (5) The Public Works Department may refuse service to any bulk container that is no longer in serviceable condition to rust, wear, or other damage. (6) It shall be the duty of the commercial user to maintain the bulk container in a reasonably clean and sanitary condition. (c) Rental property. The owner and tenant of each rental property shall have joint and several liability for any violation of this section. (d) Proper disposal. It shall be unlawful for any person to place any material in any bulk container, or garbage roll-out cart, which at the time of collection is not qualified for municipal solid waste disposal at the County solid waste landfill or Resource Recovery Center. (Code 1994, § 3-2-4; Ord. No. 1979-16, 10-14-1979; Ord. No. 1997-16, § 3, 8-26-1997) Sec. 3-2-5. Trash collection. (a) No waste which at the time of collection is defined by the United States Environmental Protection Agency or the State Department of Health and Environmental Control as hazardous waste shall be collected by the City. (b) No tires, batteries, motor oil, petroleum products or auto parts of any kind will be collected by the City. No paint shall be mixed in with household trash into city roll carts. Paint spillage on to city, state or private roads is not the responsibility of the Isle of Palms public service department. Proper disposal of same shall be the responsibility of the owner or person in possession of the same. (c) Leaves and grass clippings. All leaves and grass clippings shall be placed at the curb in front of the property in bio-degradable paper bags or plastic containers for collection. No plastic bags shall be used for the disposal of leaves or grass clippings. No household garbage or other materials may be placed with leaves or grass clippings. No mixed materials or plastic bags will be collected by the City. Home composting of leaves and grass clippings is encouraged. (d) Logs, limbs, brush, and like materials shall be placed at the curb in front of the property in the following manner: 35 Created: 2026-01-06 12:52:58 [EST] (Supp. No. 27) Page 12 of 42 (1) Length of material shall not exceed four feet. (2) Diameter of material shall not exceed four inches. (3) The City will only collect materials as listed in this category which are generated by routine landscape maintenance on developed lots. Debris generated by grading or clearing of undeveloped property shall be disposed of by the party generating such debris. The city will not collect materials listed in this category which are generated by landscapers, tree services or other contractors. Debris resulting from commercial landscaping maintenance operations tree service or other contractors shall be removed and legally disposed of by the contractor. (4) When placed at the curbside for collection, materials shall not obstruct access to water meters, stormwater collection boxes, sewer manhole covers, or fire hydrants. (5) No garbage shall be mixed with the items listed in this category. (6) No plastic bags shall be used for the disposal of any items listed in this category. (e) Building materials, furniture or other trash shall be placed at the curb in front of the property for collection in the following manner: Builder refuse which is generated exclusively by an owner or resident shall be collected by the city when the volume of the said material does not exceed limits outlined in the Solid Waste Services Collection Procedures (1) Any single collection day will be limited to the equivalent of ninety ( 19280 ) gallons in volume the equivalent of two trash carts. (2) No hazardous waste as defined in subsection (a) of this section will be collected by the City. (3) No roofing shingles will be collected by the City. (4) No building materials or other trash generated by a contractor shall be collected by the City. (5) Items within this category shall be separated at the curb for collection. Any materials in these categories that are mixed together shall not be collected by the City. (6) No garbage shall be mixed with the items in this category. (f) Collection days shall be designated by the City from time to time. Reasonable notice will be given by the City of collection schedules or practices. (Code 1994, § 3-2-5; Ord. No. 1993-8, 5-25-1993; Ord. No. 1997-16, § 4, 8-26-1997; Ord. No. 1998-8, 4-28-1998; Ord. No. 2011-03, § 1, 3-22-2011) Sec. 3-2-6. Removal of contractors' and builders' refuse. Contractors' and builders' refuse , generated by a contractor, bricks, scraps of lumber, mortar, plaster, roofing, guttering, shavings, vegetative debris and all other like materials shall be removed by the contractor, owner or tenant of the premises, each being jointly and severally responsible for such removal. (Code 1970, § 18-7; Code 1994, § 3-2-6; Ord. of 1-13-1977) Sec. 3-2-7. Scattering of contents or rummaging through garbage containers. It shall be unlawful for any person to dump, scatter or spread, or allow to be dumped, scattered or spread, the contents of garbage carts, bags or containers, public or private, on any property in the City, and further it shall be unlawful for any person to enter upon or rummage or plunder through the contents of any garbage cart, bag or 36 Created: 2026-01-06 12:52:58 [EST] (Supp. No. 27) Page 13 of 42 container of another, or to use the container or trash enclosure of another without permission. Placing items on vacant parcels or on any public or on any public property shall be considered illegal dumping. (Code 1970, § 18-9; Code 1994, § 3-2-7; Ord. of 1-13-1977; Ord. No. 1997-16, § 5, 8-26-1997) Sec. 3-2-8. Garbage roll-out carts and county recycling containers shall not be kept upon street or road rights-of-way. Garbage roll-out carts and county recycling containers shall not be placed in the right-of-way of a street or road except when placed for collection. Garbage carts and recycling containers shall not be placed for collection prior to 5:00 p.m. on the day before collection. Garbage carts and recycling containers shall be removed from the right-of-way no later than 9:00 a.m. on the day following collection. Except for such times when lawfully placed for collection, no garbage carts or recycling containers shall be allowed to remain clearly visible from a street, road, or right-of-way. Garbage carts and recycling containers located on publicly owned areas, including, but not limited to, public parking lots, public parks, public beach and recreational areas, or any City-owned property, are exempt from the requirements of this section. The City has the right to move garbage carts and recycling containers placed in violation of this section. (Code 1970, § 18-10; Code 1994, § 3-2-8; Ord. of 1-13-1977; Ord. No. 1997-16, § 6, 8-26-1997; Ord. No. 2001-3, § 1, 2-27-2001; Ord. No. 2013-03, § 1, 5-28-2013) Editor's note(s)—Ord. No. 2013-03, § 1, adopted May 28, 2013, changed the title of § 3-2-8 from garbage roll-out carts shall not be kept upon street or road rights-of-way to garbage roll-out carts and county recycling containers shall not be kept upon street or road rights-of-way. PAPER AND CARDBOARD. (A) Paper and cardboard boxes in large quantities shall be disposed of at a recycling center. (B) If being disposed in the Charleston County blue recycling carts, cardboard boxes must be broken down and fit loosely in the cart. Sec. 3-2-9. Collection. All garbage generated from residential property will be collected in accordance with schedules established by the City from time to time. Scheduled collections of, garbage, trash shall be collected according to the schedule established by the Director of Public Services Department. Property owners and tenants shall be notified of such schedule change or practices by public notice. (Code 1994, § 3-2-9; Ord. No. 1997-16, § 7, 8-26-1997) Sec. 3-2-10. Placing garbage roll-out carts for collection. When placing garbage roll-out carts for collection, they shall be placed within ten (10) feet of the edge of the pavement of the street. Carts which are not placed in a location which is easily accessible by collection personnel and equipment will not be emptied. The handles of the carts shall be faced toward the street unless otherwise notified with the implementation of the automatic side loading garbage truck which will effect handle placement.. (Code 1994, § 3-2-10; Ord. No. 1997-16, § 8, 8-26-1997) 37 Created: 2026-01-06 12:52:58 [EST] (Supp. No. 27) Page 14 of 42 Sec. 3-2-11. Collection of major household appliances. The collection of major household appliances such as refrigerators, washing machines, dryers, dishwashers, furniture, bed mattresses, etc., are to be placed out Tuesday night for Wednesday pick up, unless otherwise agreed to by the Public Works Department. . (Code 1970, § 18-13; Code 1994, § 3-2-11) Sec. 3-2-12. Penalties for noncompliance with or violation of this chapter. Any person violating any provision of this chapter shall, upon conviction, be punished as provided in section 1-3-66. A violation of this chapter shall not be considered as a continuing offense, but each day that this chapter is violated shall be a separate and distinct offense. (Code 1994, § 3-2-12; Ord. No. 1979-16, 10-14-1979) Sec. 3-2-13. Definition of curb. For purpose of this chapter, the term "curb" shall include the edge of a street, road or right-of-way. (Code 1994, § 3-2-13; Ord. No. 2001-3, § 2, 2-27-2001) CHAPTER 3. STORMWATER REGULATIONS ARTICLE A. STORMWATER MANAGEMENT UTILITY3 Sec. 3-3-1. Article designation and authority. This article may be cited as the "Stormwater Management Utility Ordinance" and is adopted pursuant to S.C. Code 1976, § 48-14-10 et seq.; S.C. Code 1976, § 5-7-30; and S.C. Code Reg. 72-300 et seq., and S.C. Code 1976, § 5-31-10 et seq. (Ord. No. 2007-14, § 2(3-3-1), 8-28-2007) Sec. 3-3-2. Definitions. The following words, terms and phrases, when used in this article, shall have the meaning ascribed to them in this section, except where the context clearly indicates a different meaning. Unless otherwise stated herein or the context specifically indicates otherwise, the meaning of words and terms used in this article shall be as set forth in S.C. Code 1976, § 48-10-20 and S.C. Code Reg. 72-301. City means the City of Isle of Palms, South Carolina. City Administrator means the City Administrator of the City. 3State law reference(s)—Stormwater Management and Sediment Reduction Act, S.C. Code 1976, § 48-14-10 et seq.; standards for stormwater management and sediment reduction, S.C. Code Reg. 72-300 et seq. 38 Important Notice: The information contained in this proposal is proprietary to Geosyntec Consultants Inc. and is intended solely for the lawful use of the persons/parties named above; it must not be used for any other purpose other than its evaluation; and it must not be divulged to any other third party, in whole or in part, without the prior written permission of Geosyntec. Initials: ______ (Client) Initials: ______ (ATM) PROPOSAL FOR CONSULTING SERVICES MARINA BULKHEAD COATING MAINTENANCE ISLE OF PALMS MARINA PREPARED FOR: The City of Isle of Palms Attn: Mr. Douglas Kerr June 9, 2026 GEOSYNTEC CONSULTANTS, INC. 39 Geosyntec Consultants, Inc. Page 2 of 4 PROPOSAL FOR CONSULTING SERVICES INTRODUCTION Geosyntec Consultants (formerly Applied Technology & Management, Inc.) respectfully submits this proposal to the City of Isle of Palms (the City) to provide professional services associated with the assessment, design, bidding, and construction support for maintenance recoating of the existing steel sheetpile bulkhead at the Isle of Palms Marina. About Geosyntec Geosyntec is a specialized consulting and engineering firm that has been working with private and public sector clients for more than 40 years to address complex problems involving the environment, natural resources, and civil infrastructure. In 2021, Geosyntec acquired Applied Technology and Management (ATM), who has previously supported the City with related consulting services. Project Background In 2020 and 2021, Geosyntec (then ATM) supported the City with development of a bulkhead re- coating program, bidding support, and observation of the completed maintenance work. Bulkhead coating was required following moderate corrosion and coating degradation identified, primarily within the splash zone and concentrated along seams, joints, and other vulnerable features. The City has identified the bulkhead is due for maintenance and recoating. At the request of the City, Geosyntec performed an initial screening of the current condition of the bulkhead. The bulkhead again shows signs of corrosion and need for maintenance. Geosyntec has recommended the following steps: • Update plans and specifications for recoating • Assist with bid process • Perform limited construction phase services To support these objectives, Geosyntec proposes the following scope of services. TASK 1: UPDATE BULKHEAD COATING PLANS Under this task, Geosyntec will formalize our cursory, visual assessment of the bulkhead to document the current condition of the exposed/outer face of the wall. As part of this effort, we will coordinate with the coating product manufacturer to assess the performance of the wall coating to date and i dentify any recommendations for additional or alternative coating products or application methods for improved performance / longevity. ATM will update our bulkhead maintenance plan for patching and recoating the exterior/exposed side of the bulkhead with a specific focus on the sheets, hardware, and walers. The plan will include a plan view and sections of the proposed maintenance as well as specification of surface preparation and coating treatment . Our estimated effort and associated fee assume minor revisions and updates to the 2021 bid package. On completion of this task, we will notify SCDHEC- OCRM of the proposed maintenance. We assume no permitting is required as part of this scope of services and do not expect this requirement (as was the case previously). Deliverables: Summary memo of observations; Basic plan & section drawings with technical specification. 40 Geosyntec Consultants, Inc. Page 3 of 4 TASK 2: PROJECT BIDDING ASSISTANCE We assume that the City will lead a formal bid process to solicit competitive bids from qualified contractors to complete the maintenance works. To support the City, we propose to provide limited assistance to this process. This is assumed to include: • Review and c ompile the bid package for distribution by the City. The package will include documentation prepared by the City (i.e. Invitation, Instructions, Bid Form, Form of Contract) and the technical drawings and specification • Participate in pre-bid meeting with the City • Respond to technical inquiries • Review of bids received for conformance and recommendation for award (as desired by the City). Geosyntec’s efforts are assumed to be limited. Should additional support be required, we will be pleased to revisit the level of service offered and the associated fee. Deliverables: Compiled bid package, bid tabulation, and recommendation. TASK 3: LIMITED CONSTRUCTION PHASE SERVICES Geosyntec will provide limited construction phase services for the project, including: • Coordinate and lead pre-construction meeting on site • Review Contractor submittals (coating materials, etc.) • Conduct 3 field observations of the work at milestones below: o 1) at ~10% completion to review contractor performance and approach, o 2) at substantial completion of the field work, and o 3) at final completion. • Review and certify contractor payment applications (assume 2) Deliverables: Pre-construction meeting agenda and minutes, documentation of field observations (3 memoranda), two certified payment applications. TASK 4: ADDITIONAL MEETINGS AND COORDINATION (T&M) Where the City or the Contractor team requires additional coordination with G eosyntec, we include this task that may be used for team meetings, calls, presentation, preparation of additional documentation, etc. on a time and material basis for efforts in addition to the above prescribed scope of work. This task may also include coordination between team members, advice, extra site visits, or other services not specifically included herein. We will notify the City if the efforts demanded may exceed the budgeted allowance. Geosyntec hourly billing rates will apply. 41 Geosyntec Consultants, Inc. Page 4 of 4 FEES AND SPECIFIC CONDITIONS Task 1-3 fees below include estimated professional labor fees and expenses . Task 4 is offered on a Time & Materials allowance basis. Task Professional Fee (USD) 1. Update Bulkhead Coating Plans $8,000 2. Project Bidding Assistance $8,000 3. Limited Construction Phase Services $13,000 4. Additional Meetings & Coordination (T&M Allowance) $4,000 Total $33,000 Geosyntec services may be initiated immediately upon the acceptance of this proposal and execution of a professional services agreement (PSA). 2026 Geosyntec hourly billing rates Staff Professional $175 Senior Staff Professional $200 Professional $227 Project Professional $254 Senior Professional $280 Principal $305 Senior Principal $325 Project Administrator $94 Clerical $78 42 P26-038.docx August 8, 2026 Douglas Kerr City of Isle of Palms 1207 Palm Blvd. Isle Of Palms, SC 29451 Via email: Douglas Kerr <dkerr@isleofpalms.gov> RE: Professional Engineering and Construction Administration Services City of Isle of Palms Marine Steel Bulkhead Re-Coating Isle of Palms, South Carolina Mr. Kerr, Outlined below is the scope of work and fee schedule for professional services associated with development of the re-coating plans and specifications for the re-coating of the steel bulkhead at the City of Isle of Palms Marine, Isle of Palms, South Carolina. Scope of Services: The scope of services in this contract includes the following: TASK 1: ASSESSMENT AND RECOMMENDATIONS JGT will work with Industry Standard Engineers & Consultants – PLLC (ISEC) and an AMPP (formerly National Association of Corrosion Engineers - NACE) Coating Inspector to develop options, and probable cost estimates for the re-coating of the steel bulkhead. This will include:  Work with a NACE Coatings Inspector to conduct a site visit to review and inspect the existing bulkhead.  Review the original coating information and specifications of the steel sheets and components, review the information and specifications of the re-coating of the steel sheets in 2020/2021. This will include materials used, techniques for re-coating that were used and inspection reports.  Develop options for the re-coating of the steel bulkhead. This will include coating options and alternative corrosion prevention systems.  Develop probable cost estimates for each of the options.  Develop a brief report outlining the re-coating options, pros and cons of each, estimated life expectancy and probable costs. 43 P26-038.docx  Review with the City of Isle of Palms and make recommendations for re- coating. Assessment and Recommendations ................................................ $8,500.00 Total Assessment and Recommendations Fees ................................... $8,500.00 TASK 2: RECOATING PLANS AND SPECIFICATIONS JGT will work with ISEC and an AMPP Coating Inspector to develop a complete plan and specification package for the re-coating of the steel bulkhead at the City of Isle of Palms Marina. This will include:  Use the information from Task 1 and the selected recoating option to develop the plans and specifications package.  Specifications and plans include: minimum product specifications, minimum recoating process requirements and testing and inspection requirements.  Plans and specification will meet Association for Materials Protection and Performance (AMPP) minimum specifications for preparation, application, testing and inspections.  Present package to the City of Isle of Palms for review, revisions and approval. Recoating Plans and Specifications ................................................ $21,500.00 Total Recoating Plans and Specifications Fees ................................... $21,500.00 TASK 3: RECOATING INSPECTION AND OVERSIGHT JGT will work with ISEC and an AMPP Coating Inspector to inspect, test and oversee the recoating process. This will include:  Conduct a pre-construction meeting with the selected Contractor to ensure the product, preparation, recoating, testing and inspection requirements are adhered to and review the recoating project procedures and schedule.  Answer questions and address issues or changes during the recoating process.  Conduct regular site visits to oversee recoating process  Weekly project meetings with City of Isle of Palms, Contractor and JGT to review progress, issues and schedule.  Review inspection and testing reports.  Conduct walk-thru with Contractor for section and overall approval of recoating.  Conduct substantial completion punch list walk-thru with Contractor.  Conduct final walk-thru with Contractor and issue final approval.  Finalize all warranty and final approval package items. 44 P26-038.docx Recoating Inspection and Oversight .............................................. $30,000.00 Total Recoating Inspection and Oversight Fees ................................. $30,000.00 FEES TOTALS: TASK 1: Assessment and Recommendations: .................................... $8,500.00 TASK 2: Recoating Plans and Specifications: ..................................... $21,500.00 TASK 3: Recoating Inspection and Oversight: ................................... $30,000.00 Total: ............................................................................................... $60,000.00 Terms and Conditions: Reimbursable expenses are in addition to the Basic Services and will be billed at cost plus 10%. These include printing and plotting fees beyond what is reasonable for the above Scope of Work, mileage ($0.70 per mile) and application or permit fees. Anticipated Reimbursables: none Invoices will be rendered monthly based on percentage completed in accordance with the fees outlined for this Scope of Work. Payments are due within thirty days of the date of the invoice. Invoices not paid within forty-five days of date rendered will be assessed as a finance charge of one percent per month, or fraction thereof, for every month past due. Invoices not paid within sixty days will result in Jon Guerry Taylor & Associates, Inc. stopping work until such invoices are paid in full. Jon Guerry Taylor & Associates, Inc. will commence work upon receipt of the signed and dated proposal by the Owner. The professional services shall be completed within the allotted time outlined in this Scope of Work with adjustments made to the schedule based upon changes or directions from the Owner. Any changes to the Scope of Work or schedule shall be mutually agreed to in writing by the Owner and Jon Guerry Taylor & Associates, Inc. prior to implementation. Jon Guerry Taylor & Associates, Inc. will perform the work in a timely manner but will not be held responsible for delays that occur from factors beyond their control or that could not have been reasonably foreseen at the time this Proposal was executed. Limits of Liability: The Owner and Jon Guerry Taylor & Associates, Inc. mutually agree that the services provided pursuant to this Proposal involve risk of liability, which cannot be adequately compensated for by payments the Owner makes under this Proposal. Therefore, the total cumulative liability of Jon Guerry Taylor & Associates, Inc., it’s agent(s) and employee(s) including negligence (whether sole or concurrent) and strict liability, or otherwise arise out of, connected with or resulting from services provided pursuant to this Proposal shall not exceed the total fees paid by the Owner. Should you have any questions or comments once you have reviewed the above Scope of Services, please feel free to give us a call at (843) 884-6415. 45 P26-038.docx Sincerely, JON GUERRY TAYLOR & ASSOCIATES, INC. Christopher Moore, P.E. President/Principal Engineer cc: Craig Pawlyk, JGT 46 P26-038.docx Background and Team: Jon Guerry Taylor & Associates, Inc. (JGT) has been involved with projects within the Morgan Creek basin for over 30+ years. This includes working with the Morgan Creek Homeowners Association (MCHA) on Dredging, dock replacement and the installation of a cathodic protection system and recoating of the MCHA steel bulkhead. JGT has worked with Dewees Island on the inspection of the existing aluminum bulkhead and was involved in the design of elements of the marina replacement. JGT has conducted several condition assessments of the original timber bulkhead at the City of Isle of Palms Marina and in 2008, permitted, design and conducted construction oversight of the bulkhead replacement of the original timber bulkhead with the existing steel sheet pile bulkhead. JGT was involved in the design of several structural elements of the City of Isle of Palms Marina redevelopment. JGT has designed hundreds of bulkheads along the coast of South Carolina and North Carolina. In addition, JGT has been involved in several steel recoating projects including the MCHA steel bulkhead rehabilitation and recoating project and the Waterfront Plantation Bulkhead inspection and recoating project. JGT worked with Southern Cathodic Protection, Inc. to develop the cathodic protection system and recoating of the 6,000 linear feet of steel bulkhead around the Morgan Creek Basin. Chris Moore, PE is the President and Principal Engineer at JGT. He has over 26 years of experience with bulkhead inspections, design and construction. Chris was the design engineer on the City of Isle of Palms Marina bulkhead replacement in 2008/2009 and other design elements of the marina replacement. He was the JGT Project Manager representative for the MCHA bulkhead recoating and cathodic protection project Team. Caleb Wright, PE, is the Principal Engineer of Industry Standard Engineers & Consultants – PLLC (ISEC) with more than 30 years of experience in metallurgical, corrosion, and cathodic protection engineering. MR. Wright served as the on-site engineering lead for the MCHA steel bulkhead rehabilitation and recoating project, directing the redevelopment and validation of the coating specification, cathodic protection design, leak remediation, and structural repairs. Mr. Wright has provided corrosion engineering services for the U.S. Army Corps of Engineers, Department of Defense, industrial clients, and local governments on projects involving waterfront structures, tanks, pipelines, and process equipment. He holds AMPP certifications in Coating Inspection and Cathodic Protection and is licensed as a Professional Engineer in multiple states. Mr. Moore and Mr. Wright worked on the MCHA bulkhead re-coating project as project engineers together. Mr. Wright and ISEC will be part of the Team for the City of Isle of Palms Marina Recoating project. Mr. Craig Pawlyk with JGT will oversee the regulatory agencies permitting approvals. Resumes Attached 47 JGT - P.O. Box 1082 Mt. Pleasant SC 29465 - Ph. (843)884-6415 Fax (843)884-4025 - Website: www.jgtinc.com CHRISTOPHER W. MOORE, P.E. 2008 to Present - Jon Guerry Taylor, & Associates, Inc., President/Principal Engineer 2000-2007 - Zande - Jon Guerry Taylor, P.E., Inc., Associate Engineer / Assistant Manager Responsible for business development, project coordination, contracts, financial and company management. Technical involvement in engineering and planning includes project management and engineering design of waterfront projects and structures, docks, bulkheads , marinas and piers. Other civil engineering duties include permitting and design of water and wastewater systems, storm drainage systems, roadway systems requiring general civil engineering expertise. Project Management tasks include complete preparation of engineering construction drawings and specificat ions, communications with owners, contractors, and regulatory authorities associated with projects, cost estimating, bidding administration, and construction supervision/inspection. Years with this firm: 26 Years with other Firms: 4 Total Experience: 30 years RELEVANT PROJECTS: Cumberland Island National Park Boat Ramp Replacement, Cumberland Island, GA Congaree National Park Pedestrian Bridge and Kayak Launch; Hopkins, SC Morgan Creek Dredging; Isle of Palms, SC Morgan Creek Bulkhead Recoating and Renovations; Isle of Palms, SC Waterfront Plantation Bulkhead Recoating; Charleston, SC James Island Yacht Club Dredging, Charleston, SC Remley’s Point Boat Landing Replacement and Expansion; Mount Pleasant, SC Ebenezer Park Fixed Pier, Kayak Launch and Dredging; York County, SC Clark Island Dry Stack and Marina; Johns Island, SC Northbridge Park Kayak Launch and Fishing Pier; Charleston, SC Calhoun Falls State Park Marina; Abbeville, SC James Island Yacht Club Dock Replacements; Charleston, SC Congaree National Park Boardwalk Replacement, Phase 1 and Phase 2; Hopkins, SC Natchez Trace National Parkway Pedestrian Bridges; Mississippi Limehouse Bridge Fishing Pier; Charleston, SC Wando Marina, Berkeley County, SC Governors Park Marsh Boardwalk; Daniel Island, Charleston, SC Isle of Palms Municipal Marina Bulkhead Replacement; Isle of Palms, SC Richardson’s Landing Breakwater; Lake Moultrie, SC EDUCATION: B.S. Civil Engineering, The Citadel, The Military College of South Carolina, 1997 Structural Engineering Graduate Certificate Program; The Citadel Graduate School PROFESSIONAL REGISTRATION: Professional Engineer; South Carolina No. 22003 Professional Engineer; North Carolina No. 59680 Professional Engineer; Mississippi No. 32442 Professional Engineer; Georgia No. 32534 National Council of Examiners for Engineering and Surveying (NCEES) No. 28717 MEMBERSHIPS AND ACTIVITIES: Member of American Society of Civil Engineers (ASCE) 48 JGT - P.O. Box 1082 Mt. Pleasant SC 29465 - Ph. (843)884-6415 Fax (843)884-4025 - Website: www.jgtinc.com CRAIG A. PAWLYK, R.L.A., A.S.L.A., A.I.C.P. 2008 to Present – Jon Guerry Taylor & Associates, Inc., Vice-President/Director of Critical Area Permitting 2001-2007 - Zande - Jon Guerry Taylor, P.E., Inc., Planning Project Manager Environmental Permitting duties include preparation and administration of Regulatory permits including Army Corps of Engineers, SCDES Navigable Water Permits and SCDES-BCM Critical Area permits (including docks, marinas, dredging, boat ramps, piers, boardwalks ), and SCDES 401 Water Quality Certifications. Additional r esponsibilities include preparation of public waterfront recreation land use plans, conceptual master plans, and marina facilities planning as well as construction documents for waterfront commercial and recreational projects. Years with this firm: 24 Y ears with other Firms: 4 Total Experience: 28 years RELEVANT PROJECTS: Morgan Creek Dredging; Isle of Palms, SC Morgan Creek Bulkhead Recoating and Renovations; Isle of Palms, SC James Island Yacht Club Dredging, Charleston, SC Hidden Cove Marina, Moncks Corner, SC Harborage at the Ashley Marina, Charleston, SC The Pointe at Rivertown Community Dock, Mt. Pleasant, SC Riverland Terrance Boat Ramp, Charleston, SC Atlantis Marine Docks and Dredging, Berkeley County, SC Beaufort County SC Boat Landing Study, Beaufort County, SC Remleys Point Boat Landing Replacement and Expansion; Mount Pleasant, SC Ebenezer Park Fixed Pier, Kayak Launch and Dredging; York County, SC Northbridge Park Kayak Launch and Fishing Pier; Charleston, SC Palmetto Islands County Park Kayak Launch Dock; Mount Pleasant, SC James Island Yacht Club Dock Replacements; Charleston, SC Calhoun Falls State Park Marina; Abbeville, SC Hidden Cove Marina Redevelopment; Moncks Corner, SC Limehouse Bridge Fishing Pier; Charleston, SC Charleston Waterfront Park Harbor Taxi Dock; Charleston, SC Ross Marine Drystack and Wet Slip Marina; Johns Island, Marina Town of McClellanville Observation and Fishing Pier; McClellanville, SC Shem Creek Park Dredging; Town of Mount Pleasant, SC EDUCATION: B.L.A. Landscape Architecture, Clemson University, 1994 PROFESSIONAL REGISTRATION: Landscape Architect – South Carolina – No. 826 Landscape Architect - North Carolina – No. 1245 Certified Planner (A.I.C.P.) – No. 020183 MEMBERSHIPS AND ACTIVITIES: American Society of Landscape Architects American Institute of Certified Planners American Planning Association 49 CALEB WRIGHT, PE Corrosion Engineer Industry Standard Engineers & Consultants – PLLC PROFESSIONAL SUMMARY Corrosion Engineer with 30 years of professional experience , including 12 years with Industry Standard Engineers & Consultants – PLLC , specializing in corrosion engineering, cathodic protection, protective coatings, and corrosion mitigation for water, utility, marine, and infrastructure systems. Experienced in cathodic protection system design, coating system design and inspection, field engineering, construction support, contractor coordination, and evaluation of existing corrosion-control systems. Provides hands-on technical leadership from design through construction and commissioning. CORE QUALIFICATIONS • Corrosion Engineering • Cathodic Protection System Design • Galvanic Cathodic Protection • Protective Coating Systems • Coating Inspection • Corrosion Control & Mitigation • Field Engineering & Construction Support • Utility & Water Infrastructure • Contractor Coordination • Construction Quality Assurance • Existing-System Evaluation • Technical Coordination with Owners and Contractors • PROFESSIONAL CERTIFICATIONS & QUALIFICATIONS • NACE/AMPP Cathodic Protection Technician #66725 • NACE/AMPP Basic Coating Inspector / CIP Level 1 #11038 RELEVANT PROJECT EXPERIENCE MCHA Steel Bulkhead Rehabilitation Isle of Palms, South Carolina | Professional Services: 2025 | Construction: 2025 Served as site engineering representative for Southern Cathodic Protection Company during rehabilitation of a steel bulkhead. Reworked cathodic protection, coating, repair, and leak-control plans as field conditions warranted. Managed site coating contractors and inspectors and conducted weekly coordination meetings with the owner. Provided hands -on involvement in coating inspections and contractor negotiations to address performance and ensure successful execution of the rehabilitation work. Williams Gas Pipeline Crossing – Atrium Hospital Charlotte, North Carolina | Professional Services: 2023 | Construction: 2024 Served as Corrosion Engineer providing coating system design, cathodic protection system design, and corrosion engineering services for a ductile iron water main serving the hospital. Addressed corrosion-control requirements associated with the water main's interference with two existing 30-inch gas mains. 50 Fire Water Tank Cathodic Protection RFP Stennis Space Center, Mississippi | Professional Services: 2022 Served as Corrosion Engineer providing cathodic protection design and corrosion engineering services for the fire water tank serving the facility. Developed corrosion-control recommendations supporting the cathodic protection procurement and implementation process. DIP Water Main – 361 ISRG Mission Operations Facility Hurlburt Field, Florida | Professional Services: 2024 Served as Corrosion Engineer providing galvanic cathodic protection design and corrosion engineering services for civil utility infrastructure supporting the facility. Applied corrosion-control engineering principles to protect ductile iron water main components and associated utility systems. DIP Water Main – EUPH Barracks, Camp Simons, 7th SFG Eglin AFB, Florida | Professional Services: 2024 Served as Corrosion Engineer providing galvanic cathodic protection design and corrosion engineering services for civil utilities serving the facility. Supported corrosion -control requirements for ductile iron water main infrastructure through development of an appropriate cathodic protection approach. PROFESSIONAL EXPERIENCE Industry Standard Engineers & Consultants – PLLC Corrosion Engineer | 12 years with current firm Provides corrosion engineering, cathodic protection, protective coating, inspection, and construction-support services for infrastructure and utility projects. Responsibilities include system design, field evaluation, coating inspection, construction coordination, contractor management, and technical support to owners and project teams. EXPERIENCE 30 Years Total Professional Experience 12 Years with Current Firm 51 _______ CLIENT’S INITIALS _______ CONSULTANT’S INITIALS August 27, 2026 Mr. Douglas Kerr City of Isle of Palms P.O. Drawer 508 Isle of Palms, SC 29451 Re: Waterway Boulevard Pathway Tidal Inundation Mitigation Project City of Isle of Palms, South Carolina T&H J-27670.0010 Letter Agreement for Additional Services (CO#6) Dear Mr. Kerr: Thank you for requesting additional service from Thomas & Hutton (T&H) to continue to assist the City with the implementation of this very important and impactful project for City residents. As you are aware, the City is currently constructing the pathway project within the SCDOT right-of-way. During construction, numerous unexpected utility conflicts and field adjustments have occurred, requiring additional time and extending the construction timeline. Our original design and permitting contract (October 1, 2023), and our previous additional services agreements (CO#1, CO#2, CO#3, CO#4, CO#5) did not include the extended construction work listed under this change order (CO#6). Please see the attached table for the current project/contract fee and the proposed fee for this additional services request. If acceptable, please indicate your authorization to proceed with this additional work by signing and initialing where designated below and returning a copy to us for our files. This Proposal will be open for acceptance for 90 days, unless changed by us in writing. Please note that no work will be performed without prior written authorization to proceed. This extra work is subject to the terms and conditions of the Contract executed for this Project dated October 1, 2023. This Proposal between The City of Isle of Palms (Owner), and Thomas & Hutton Engineering Co. (Consultant), consisting of the Consulting Services on a Time & Expense Basis Rate Sheet, and Exhibit “A,” represent the entire understanding between you and us with respect to the Scope change. This agreement may only be modified in writing if signed by both of us. 52 Mr. Douglas Kerr City of Isle of Palms Letter Agreement for Additional Services August 27, 2026 Page 2 _______ CLIENT’S INITIALS _______ CONSULTANT’S INITIALS We appreciate this opportunity to be of service to you on this Project. Should you have any questions or need further information, please do not hesitate to call us. Very truly yours, THOMAS & HUTTON ENGINEERING CO. By Richard Karkowski, PE, PH, D.WRE Water Resources Department Manager RPK/ Enclosures: Exhibit “A” – Additional Services Fee Table 2026 Consulting Services Rate Sheet CITY OF ISLE OF PALMS ACCEPTED: _________________________, 2026 By _______________________________________ ________________________________________ TITLE 53 EXHIBIT “A” TO LETTER AGREEMENT FOR ADDITIONAL SERVICES BETWEEN THOMAS & HUTTON ENGINEERING CO. (CONSULTANT) AND THE CITY OF ISLE OF PALMS (OWNER) WATERWAY BOULEVARD PATHWAY TIDAL INUNDATION MITIGATION PROJECT AUGUST 27, 2026 _______ CLIENT’S INITIALS 1 of 2 _______ CONSULTANT’S INITIALS EXHIBIT “A” 1. ADDITIONAL SERVICES OF CONSULTANT (CO#6) A. General Consulting Phase Consultant shall attend construction progress meetings and additional meetings at the request of the Owner. B. Construction Phase Consultant will review material data, shop drawings, and construction schedules provided by the Contractor. Consultant will periodically observe construction of the project to ensure compliance with construction drawings and intent of the project. Construction observation and monitoring does not include exhaustive or continuous on–site inspections. However, it does include visits to the Project site at intervals appropriate to the various stages of construction to review general compliance with approved plans and intent of the project. The Consultant shall address the Contractors questions, requests for additional information, etc. The Consultant shall visit the site as needed to address potential field changes. The Consultant shall advise the City as to suitability of the work and percent completion of the work. C. Exclusions Items not included in the additional Scope of Services are as follows: • Accessibility construction compliance verification • Archaeological survey and report • Easement plat recording • Phase One or Phase Two environmental assessments • Endangered species survey and report • Materials Testing • Off–site work unless specifically covered in the Scope of Services • As-built surveys • Approvals or permits other than those related to the Scope of Work covered by this Contract • Act as an expert witness for legal activities These items can be coordinated or provided, if requested by the Owner in writing. 54 Phase Fee Structure Fee or Time & Expense Budget Feasibility Add. Serv. (April 2024) Total Revised Budget Design Add. Serv. Total Revised Budget Design Add. Serv. Total Revised Budget Design, Survey, Bid, and CE&I Add. Serv. Total Revised Budget Previous Invoiced Pending Nov. 2025 Invoice Budget Remaining Previous Invoiced Total Revised Budget CE&I Add. Serv. Total Revised Budget General Consulting Time & Expense - Budget 22,400$ 1,000$ 23,400 $ 20,000 $ 43,400 $ 43,400 $ 5,000$ 48,400 $ 34,464.60$ 2,600.00$ 11,335.40$ 48,400 $ 5,000 $ 53,400$ Survey Lump Sum 50,000$ 50,000$ 50,000$ 50,000$ 7,500$ 57,500$ 57,500.00$ -$ 57,500$ 57,500$ Survey - Easement Plats Lump Sum (3 easements) 4,100$ 4,100$ 4,100$ 2,500$ 6,600$ 3,500$ 10,100$ 9,940.00$ 160.00$ 10,100$ 10,100$ Design Lump Sum 44,600$ 44,600$ 45,000$ 89,600$ 89,600$ 35,000$ 124,600$ 124,600.00$ -$ 124,600$ 124,600$ SW Mang. (Feasibility) Lump Sum 13,500$ 13,500$ 13,500$ 13,500$ 13,500$ 13,500.00$ -$ 13,500$ 13,500$ Permitting Time & Expense - Budget 35,600$ 35,600$ 35,600$ 2,500$ 38,100$ 38,100$ 38,100.00$ -$ 5,000$ 43,100$ 43,100$ Bidding (and Cont. Neg.) Time & Expense - Budget - $ 7,500$ 7,500 $ 7,500.00$ - $ 15,000 $ 22,500 $ 22,500$ Construction Services Time & Expense - Budget -$ 25,000$ 25,000$ 4,248.25$ 1,965.00$ 18,786.75$ 55,000$ 80,000$ 30,000$ 110,000$ Reimbursable Expenses Time & Expense - Budget 2,000 $ 2,000 $ 2,000 $ 2,000 $ 115.63$ 1,884.37$ 2,000 $ 2,000$ TOTAL: 156,700$ 14,500$ 171,200$ 67,000 $ 238,200$ 5,000 $ 243,200$ 83,500$ 326,700$ 289,968$ 4,565$ 32,166.52$ 75,000 $ 401,700 $ 35,000 $ 436,700$ Add. Serv. No. 5 Proposed Fee Add. Serv. No. 6Original Proposal (August 2023) Add. Serv. No. 1 Add. Serv. No. 2 Add. Serv. No. 3 Project Budget as of October 25, 2025Add. Serv. No. 4 Additional Services Request No. 6 - Construction for Pathway (SCDOT Right-of-way) Pathway Widening and Tidal Inundation Mitigation Project Waterway Boulevard 55 ____________ CLIENT´S INITIALS ____________ CONSULTANT´S INITIALS 2026 CONSULTING SERVICES RATE SHEET WWW .THOMASANDHUTTON .COM Revised May 28, 2026 Thomas & Hutton provides services on a time and expense basis as follows: 1. This basis includes allowance for direct salary expenses and for direct non–salary expenses. It also provides for services we may subcontract to others. 2. Direct salary expenses are generally based upon our payroll costs. The payroll costs include the cost of salaries and wages (including sick leave, vacation, and holiday pay) for time directly chargeable to the project; plus, unemployment, excise, payroll taxes, and contributions for social security, employment compensation insurance, retirement benefits, and medical and insurance benefits. The current hourly rate charges for each skill position for 2026 are as follows: Hourly Rate Engineer Survey Landscape GIS Quality Control Business/ Administrative $ 325.00 Consultant Consultant Consultant Consultant Consultant $ 305.00 Senior Manager Senior Manager Survey Party (3–Men) Senior Manager Senior Manager Senior Manager Senior Manager $ 285.00 Project Manager V Project Engineer V Survey Manager V Project Surveyor V Landscape Architect V LA Project Manager V GIS Manager V $ 265.00 Project Manager IV Project Engineer IV Survey Manager IV Project Surveyor IV Landscape Architect IV LA Project Manager IV GIS Manager IV Senior Application Developer IV, Software/Computer Consultant IV $ 245.00 Project Manager III Project Engineer III Survey Manager III Project Surveyor III Landscape Architect III LA Project Manager III GIS Manager III Senior Application Developer III, Software/Computer Consultant III $ 230.00 Project Manager II Project Engineer II Designer VI Survey Manager II Project Surveyor II Survey Party (2–Men) Landscape Architect II LA Project Manager II Landscape Designer VI GIS Manager II Construction Administrator II Senior Application Developer II, Software/Computer Consultant II $ 215.00 Project Manager I Project Engineer I Designer V Engineering Technician V Survey Manager I Project Surveyor I Landscape Architect I LA Project Manager I Landscape Designer V GIS Manager I Construction Administrator I Field Representative V Grant Administrator, Senior Application Developer I, Software/Computer Consultant I $ 195.00 Designer IV Engineering Technician IV Staff Surveyor V Survey Field Supervisor Landscape Designer IV GIS Analyst IV Field Representative IV Application Developer IV $ 180.00 Designer III Engineering Technician III Staff Surveyor IV Landscape Designer III GIS Analyst III Field Representative III Application Developer III Permit Coordinator III Project Coordinator III $ 165.00 Designer II Engineering Technician II Staff Surveyor III Survey Party (1–Man) Landscape Designer II GIS Analyst II Field Representative II Application Developer II Permit Coordinator II, Project Coordinator II, Admin IV $ 150.00 Designer I Engineering Technician I Staff Surveyor II Landscape Designer I GIS Analyst I Application Developer I Permit Coordinator I Project Coordinator I $ 135.00 CADD Technician III Staff Surveyor I Survey Technician III Landscape Technician III GIS Technician III $ 125.00 CADD Technician II Survey Technician II Landscape Technician II GIS Technician II Field Representative I Admin III $ 115.00 CADD Technician I Survey Technician I Landscape Technician I GIS Technician I $ 110.00 Admin II $ 100.00 Admin I $ 485.00 Expert Witness 3. When warranted, overtime will be charged for any non–salary employees. Overtime hours will be billed at 1.5 times the individual’s charge rate. 4. Direct non–salary (reimbursable) expenses, including printing, reproduction, air travel, lodging, and meals are billed at cost. Travel in company or private vehicles will be billed at the IRS Standard Mileage Rate and may be revised based on fuel pricing. Outside consultant fees will be billed at 1.15 times the cost. 5. All rates and charges are effective through December 31st, 2026, including printing, reproductions, materials, and travel and are subject to change at that time. New rates and costs will become immediately effective to contracts in effect at the time of rate changes. 56 _______ CLIENT’S INITIALS _______ CONSULTANT’S INITIALS August 26, 2026 Mr. Douglas Kerr City of Isle of Palms P.O. Drawer 508 Isle of Palms, SC 29451 Re: Waterway Boulevard Pathway Tidal Inundation Mitigation Project City of Isle of Palms, South Carolina T&H J-27670.0010 Letter Agreement for Additional Services (CO#7) Dear Mr. Kerr: Thank you for requesting additional service from Thomas & Hutton (T&H) to assist the City with the completion of this very important and impactful project for City residents. As you are aware, T&H and the City have worked together to complete the previous two phases of this project. The City has requested T&H to assist in a feasibility study for the third and final phase of the flood mitigation project. Our original design and permitting contract (October 1, 2023), and our previous additional services agreements (CO#1, CO#2, CO #3, CO#4, CO#5, and CO#6) did not include the services listed under this change order (CO#7). Please see the attached table for the current project/contract fee and the proposed fee for this additional services request. If acceptable, please indicate your authorization to proceed with this additional work by signing and initialing where designated below and returning a copy to us for our files. This Proposal will be open for acceptance for 90 days, unless changed by us in writing. Please note that no work will be performed without prior written authorization to proceed. This extra work is subject to the terms and conditions of the Contract executed for this Project dated October 1, 2023. This Proposal between The City of Isle of Palms (Owner), and Thomas & Hutton Engineering Co. (Consultant), consisting of the Consulting Services on a Time & Expense Basis Rate Sheet, and Exhibit “A,” represent the entire understanding between you and us with respect to the Scope change. This agreement may only be modified in writing if signed by both of us. 57 Mr. Douglas Kerr City of Isle of Palms Letter Agreement for Additional Services August 26, 2026 Page 2 _______ CLIENT’S INITIALS _______ CONSULTANT’S INITIALS We appreciate this opportunity to be of service to you on this Project. Should you have any questions or need further information, please do not hesitate to call us. Very truly yours, THOMAS & HUTTON ENGINEERING CO. By Richard Karkowski, PE, PH, D.WRE Water Resources Department Manager RPK/MCV Enclosures: Exhibit “A” – Additional Services Fee Table 2026 Consulting Services Rate Sheet CITY OF ISLE OF PALMS ACCEPTED: _________________________, 2026 By _______________________________________ ________________________________________ TITLE 58 EXHIBIT “A” TO LETTER AGREEMENT FOR ADDITIONAL SERVICES BETWEEN THOMAS & HUTTON ENGINEERING CO. (CONSULTANT) AND THE CITY OF ISLE OF PALMS (OWNER) WATERWAY BOULEVARD PATHWAY TIDAL INUNDATION MITIGATION PROJECT AUGUST 26, 2026 _______ CLIENT’S INITIALS 1 of 2 _______ CONSULTANT’S INITIALS EXHIBIT “A” 1. ADDITIONAL SERVICES OF CONSULTANT A. General Consulting Phase Consultant shall attend additional meetings at the request of the City. The Consultant shall prepare sketches, plans, or other documents; conduct feasibility analyses; prepare cost estimates; and conduct additional tasks as requested by the City. B. Feasibility Study Phase 1. Alternatives for protection at 3607-3615 Waterway Blvd Consultant shall create two alternatives for protection between 3607 and 3615 Waterway Blvd. The first alternative should include the flood barrier protection within the residential lots. The second alternative should provide flood barrier protection outside of the residential lots. Preliminary exhibits and drawings will be created for the two alternatives, as well as cost estimates. The Consultant shall present the feasibility of each plan and review the benefits and concerns for each alternative. 2. Alternatives for protection around fire station at 41 st Avenue Consultant shall create two alternatives to complete the flood protection barrier at 41st Avenue, including the fire station in the protected area. The first alternative should consist of the flood barrier incorporating the Dewees property. The second alternative should provide a plan for the flood barrier, not located within the Dewees property. Preliminary exhibits and drawings will be created for the two alternatives, as well as cost estimates. The Consultant shall present the feasibility of each plan and review the benefits and concerns for each alternative. C. Exclusions Items not included in the additional Scope of Services are as follows: • Construction drawings • Accessibility construction compliance verification • Archaeological survey and report • Boundary surveys • Additional Field Survey • Easement plat preparation and/or recording • Phase One or Phase Two environmental assessments • Endangered species survey and report • Materials Testing • Off–site work unless specifically covered in the Scope of Services • Approvals or permits other than those related to the Scope of Work covered by this Contract • Act as an expert witness for legal activities 59 EXHIBIT “A” TO LETTER AGREEMENT FOR ADDITIONAL SERVICES BETWEEN THOMAS & HUTTON ENGINEERING CO. (CONSULTANT) AND THE CITY OF ISLE OF PALMS (OWNER) WATERWAY BOULEVARD PATHWAY TIDAL INUNDATION MITIGATION PROJECT AUGUST 26, 2026 _______ CLIENT’S INITIALS 2 of 2 _______ CONSULTANT’S INITIALS These items can be coordinated or provided, if requested by the Owner in writing. 60 Phase Fee Structure Fee or Time & Expense Budget Feasibility Add. Serv. (April 2024) Total Revised Budget Design Add. Serv. Total Revised Budget Design Add. Serv. Total Revised Budget Design, Survey, Bid, and CE&I Add. Serv. Total Revised Budget Previous Invoiced Pending Nov. 2025 Invoice Budget Remaining Previous Invoiced Total Revised Budget CE&I Add. Serv. Total Revised Budget Add. Serv. Fee Total Revised Budget General Consulting Time & Expense - Budget 22,400$ 1,000$ 23,400 $ 20,000 $ 43,400 $ 43,400 $ 5,000$ 48,400 $ 34,464.60$ 2,600.00$ 11,335.40$ 48,400$ 5,000 $ 53,400$ 13,800 $ 67,200 $ Survey Lump Sum 50,000$ 50,000$ 50,000$ 50,000$ 7,500$ 57,500$ 57,500.00$ -$ 57,500$ 57,500$ 57,500$ Survey - Easement Plats Lump Sum (3 easements) 4,100$ 4,100$ 4,100$ 2,500$ 6,600$ 3,500$ 10,100$ 9,940.00$ 160.00$ 10,100$ 10,100$ 10,100$ Design Lump Sum 44,600$ 44,600$ 45,000$ 89,600$ 89,600$ 35,000$ 124,600$ 124,600.00$ -$ 124,600$ 124,600$ 124,600$ SW Mang. (Feasibility) Lump Sum 13,500$ 13,500$ 13,500$ 13,500$ 13,500$ 13,500.00$ -$ 13,500$ 13,500$ 49,500$ 63,000$ Permitting Time & Expense - Budget 35,600$ 35,600$ 35,600$ 2,500$ 38,100$ 38,100$ 38,100.00$ -$ 5,000$ 43,100$ 43,100$ 43,100$ Bidding (and Cont. Neg.) Time & Expense - Budget - $ 7,500$ 7,500 $ 7,500.00$ - $ 15,000 $ 22,500$ 22,500$ 22,500 $ Construction Services Time & Expense - Budget -$ 25,000$ 25,000$ 4,248.25$ 1,965.00$ 18,786.75$ 55,000$ 80,000$ 30,000$ 110,000$ 110,000$ Reimbursable Expenses Time & Expense - Budget 2,000 $ 2,000 $ 2,000 $ 2,000 $ 115.63$ 1,884.37$ 2,000$ 2,000$ 250 $ 2,250 $ TOTAL: 156,700$ 14,500$ 171,200$ 67,000 $ 238,200$ 5,000 $ 243,200$ 83,500$ 326,700$ 289,968$ 4,565$ 32,166.52$ 75,000 $ 401,700 $ 35,000 $ 436,700$ 63,550 $ 500,250 $ Additional Services Request No. 7 - Phase 3 Feasibility Study Pathway Widening and Tidal Inundation Mitigation Project Waterway Boulevard Add. Serv. No. 5 Add. Serv. No. 7 Proposed Fee Add. Serv. No. 6Original Proposal (August 2023) Add. Serv. No. 1 Add. Serv. No. 2 Add. Serv. No. 3 Project Budget as of October 25, 2025Add. Serv. No. 4 61 ____________ CLIENT´S INITIALS ____________ CONSULTANT´S INITIALS 2026 CONSULTING SERVICES RATE SHEET WWW .THOMASANDHUTTON .COM Revised May 28, 2026 Thomas & Hutton provides services on a time and expense basis as follows: 1. This basis includes allowance for direct salary expenses and for direct non–salary expenses. It also provides for services we may subcontract to others. 2. Direct salary expenses are generally based upon our payroll costs. The payroll costs include the cost of salaries and wages (including sick leave, vacation, and holiday pay) for time directly chargeable to the project; plus, unemployment, excise, payroll taxes, and contributions for social security, employment compensation insurance, retirement benefits, and medical and insurance benefits. The current hourly rate charges for each skill position for 2026 are as follows: Hourly Rate Engineer Survey Landscape GIS Quality Control Business/ Administrative $ 325.00 Consultant Consultant Consultant Consultant Consultant $ 305.00 Senior Manager Senior Manager Survey Party (3–Men) Senior Manager Senior Manager Senior Manager Senior Manager $ 285.00 Project Manager V Project Engineer V Survey Manager V Project Surveyor V Landscape Architect V LA Project Manager V GIS Manager V $ 265.00 Project Manager IV Project Engineer IV Survey Manager IV Project Surveyor IV Landscape Architect IV LA Project Manager IV GIS Manager IV Senior Application Developer IV, Software/Computer Consultant IV $ 245.00 Project Manager III Project Engineer III Survey Manager III Project Surveyor III Landscape Architect III LA Project Manager III GIS Manager III Senior Application Developer III, Software/Computer Consultant III $ 230.00 Project Manager II Project Engineer II Designer VI Survey Manager II Project Surveyor II Survey Party (2–Men) Landscape Architect II LA Project Manager II Landscape Designer VI GIS Manager II Construction Administrator II Senior Application Developer II, Software/Computer Consultant II $ 215.00 Project Manager I Project Engineer I Designer V Engineering Technician V Survey Manager I Project Surveyor I Landscape Architect I LA Project Manager I Landscape Designer V GIS Manager I Construction Administrator I Field Representative V Grant Administrator, Senior Application Developer I, Software/Computer Consultant I $ 195.00 Designer IV Engineering Technician IV Staff Surveyor V Survey Field Supervisor Landscape Designer IV GIS Analyst IV Field Representative IV Application Developer IV $ 180.00 Designer III Engineering Technician III Staff Surveyor IV Landscape Designer III GIS Analyst III Field Representative III Application Developer III Permit Coordinator III Project Coordinator III $ 165.00 Designer II Engineering Technician II Staff Surveyor III Survey Party (1–Man) Landscape Designer II GIS Analyst II Field Representative II Application Developer II Permit Coordinator II, Project Coordinator II, Admin IV $ 150.00 Designer I Engineering Technician I Staff Surveyor II Landscape Designer I GIS Analyst I Application Developer I Permit Coordinator I Project Coordinator I $ 135.00 CADD Technician III Staff Surveyor I Survey Technician III Landscape Technician III GIS Technician III $ 125.00 CADD Technician II Survey Technician II Landscape Technician II GIS Technician II Field Representative I Admin III $ 115.00 CADD Technician I Survey Technician I Landscape Technician I GIS Technician I $ 110.00 Admin II $ 100.00 Admin I $ 485.00 Expert Witness 3. When warranted, overtime will be charged for any non–salary employees. Overtime hours will be billed at 1.5 times the individual’s charge rate. 4. Direct non–salary (reimbursable) expenses, including printing, reproduction, air travel, lodging, and meals are billed at cost. Travel in company or private vehicles will be billed at the IRS Standard Mileage Rate and may be revised based on fuel pricing. Outside consultant fees will be billed at 1.15 times the cost. 5. All rates and charges are effective through December 31st, 2026, including printing, reproductions, materials, and travel and are subject to change at that time. New rates and costs will become immediately effective to contracts in effect at the time of rate changes. 62 PROJECT : Palm Blvd Drainage Improvements REVISED: LOCATION : Old Village, Mt. PleasantIsle of Palms, SC ESTIMATOR : HEA, MCV X SCDOT I TEM NO. DESCRIPTION NUMBER OF UNITS UNIT MEASURE PER UNIT TOTAL COST 1031000 Mobilization 1 LS 240,000.00$ 6011000 Traffic Control 1 LS 100,000.00$ 1050800 Construction Stakes, Lines & Grades 1 LS 65,000.00$ - As-built Construction Plans 1 LS 20,000.00$ 2011000 Clearing and Grubbing within Right-of-Way 1 LS 20,000.00$ 2023000 Removal & Disposal of Existing Pavement 455 CY 60.00$ 27,300.00$ 2106000 Selected Removal of Marked Trees 14 EA 1,500.00$ 21,000.00$ 3050108 Graded Aggregate Base Course 726 SY 50.00$ 36,300.00$ 4013990 Milling Existing Asphalt Pavement 31,385 SY 15.00$ 470,775.00$ 4020320 Asphalt Base Course Type B 82 TON 225.00$ 18,450.00$ 4040320 Asphalt Surface Course Type B 393 TON 225.00$ 88,425.00$ 6271010 4" White Solid Lines (Pvt. Edge Lines) Thermoplastic - 90 mil. 2,100 LF 4.00$ 8,400.00$ 6271015 8" White Solid Lines (Crosswalk) Thermoplastic - 125 mil. 205 LF 6.00$ 1,230.00$ 6271025 24" White Solid Lines (Stop/Diag Lines) Thermoplastic - 125 mil. 24 LF 25.00$ 600.00$ 6271074 4" Yellow Solid Lines (PVT. Edge Lines) Thermoplastic - 90 mil. 860 LF 4.00$ 3,440.00$ - 6" Sewer Service & 12" Steel Casing 18 LF 1,500.00$ 27,000.00$ - Water Service 1 EA 4,500.00$ 4,500.00$ - 8" PVC 37 LF 550.00$ 20,350.00$ - 12" PVC 76 LF 600.00$ 45,600.00$ - 14" PVC 337 LF 650.00$ 219,050.00$ - Hydrant Assembly 1 EA 12,000.00$ 12,000.00$ - 14" x 12" Reducer 1 EA 1,800.00$ 1,800.00$ - 12" x 8" Tee 1 EA 1,400.00$ 1,400.00$ - 14" x 12" Reducer 1 EA 1,500.00$ 1,500.00$ - 14" x 14" Tee 1 EA 1,600.00$ 1,600.00$ - 8" 45 Degree Bend 3 EA 1,800.00$ 5,400.00$ 8" 90 Degree Bend 1 EA 2,000.00$ 2,000.00$ - 12" 45 Degree Bend 2 EA 2,500.00$ 5,000.00$ - 14" 22.5 Degree Bend 2 EA 2,800.00$ 5,600.00$ - 14" 45 Degree Bend 6 EA 2,800.00$ 16,800.00$ - 8" Gate Valve 1 EA 8,500.00$ 8,500.00$ - 12" Gate Valve 1 EA 10,000.00$ 10,000.00$ 7141118 38" x 60" RCEP (Class III) 835 LF 900.00$ 751,500.00$ 7191205 Catch Basin - Type 9 2 EA 10,000.00$ 20,000.00$ 7192020 Drop Inlet (24" x 36") 6 EA 8,000.00$ 48,000.00$ 7192105 Manhole 1 EA 12,000.00$ 12,000.00$ 7192110 Junction Box 2 EA 10,000.00$ 20,000.00$ 7204100 Concrete Sidewalk 144 SY 100.00$ 14,400.00$ 7204900 Detectable Warning Material 20 SF 40.00$ 800.00$ 7205000 Concrete Driveway 215 SY 150.00$ 32,250.00$ 8041020 Rip Rap (Class B) 80 TON 200.00$ 16,000.00$ 8048205 Geotextile for Erosion Control Under Riprap (Class 2) Type B 110 SY 40.00$ 4,400.00$ 8131000 Sodding 6.1 MSY 12,000.00$ 73,200.00$ - Misc. Erosion Control/Water Management 1 LS 65,000.00$ SUBTOTAL 2,566,570.00$ Contingency at 10.0 % 256,700.00$ 256,700.00$ GRAND TOTAL OPINION OF CONSTRUCTION COST $2,823,300 (Other) QUANTITY COST OPINION OF PROBABLE CONSTRUCTION COST DATE PREPARED : 07/15/2025 BASIS FOR ESTIMATE (No design completed-Master Plan) (Preliminary design - 50% Design Level) (Final design - 95% level) OPINION OF PROBABLE CONSTRUCTION COST Since the Engineer has no control over the cost of labor, materials, equipment, over the Contractor's methods of determining prices, or over competitive bidding or market conditions, the Opinions of Probable Construction Costs provided for herein are made on the basis of his experience and qualifications. These opinions represent his best judgment as a design professional familiar with the construction industry. However, the Engineer cannot and does not guarantee that proposals, bids, or the construction cost will not vary from Opinions of Probable Construction Costs prepared by him. Thomas & Hutton Sheet 1 of 1 64 PROJECT : Palm Blvd Drainage Improvements REVISED: LOCATION : Old Village, Mt. PleasantIsle of Palms, SC ESTIMATOR : HEA, MCV X SCDOT I TEM NO. DESCRIPTION NUMBER OF UNITS UNIT MEASURE PER UNIT TOTAL COST 1031000 Mobilization 1 LS 430,000.00$ 6011000 Traffic Control 1 LS 150,000.00$ 1050800 Construction Stakes, Lines & Grades 1 LS 75,000.00$ - As-built Construction Plans 1 LS 25,000.00$ 2011000 Clearing and Grubbing within Right-of-Way 1 LS 25,000.00$ 2023000 Removal & Disposal of Existing Pavement 936 CY 60.00$ 56,160.00$ 2106000 Selected Removal of Marked Trees 49 EA 1,500.00$ 73,500.00$ 3050108 Graded Aggregate Base Course 1,520 SY 50.00$ 76,022.22$ 4013990 Milling Existing Asphalt Pavement 4,412 SY 25.00$ 110,300.00$ 4020320 Asphalt Base Course Type B 172 TON 225.00$ 38,700.00$ 4040320 Asphalt Surface Course Type B 497 TON 225.00$ 111,825.00$ 6271010 4" White Solid Lines (Pvt. Edge Lines) Thermoplastic - 90 mil. 2,100 LF 4.00$ 8,400.00$ 6271015 8" White Solid Lines (Crosswalk) Thermoplastic - 125 mil. 205 LF 6.00$ 1,230.00$ 6271025 24" White Solid Lines (Stop/Diag Lines) Thermoplastic - 125 mil. 144 LF 25.00$ 3,600.00$ 6271074 4" Yellow Solid Lines (PVT. Edge Lines) Thermoplastic - 90 mil. 860 LF 4.00$ 3,440.00$ - 6" Sewer Service & 12" Steel Casing 18 LF 1,500.00$ 27,000.00$ - Water Service 19 EA 4,500.00$ 85,500.00$ - 2" PVC FM 350 LF 250.00$ 87,500.00$ - 8" PVC 103 LF 550.00$ 56,650.00$ - 12" PVC 76 LF 600.00$ 45,600.00$ - 14" PVC 337 LF 650.00$ 219,050.00$ - Hydrant Assembly 1 EA 12,000.00$ 12,000.00$ - 14" x 12" Reducer 1 EA 1,800.00$ 1,800.00$ - 12" x 8" Tee 1 EA 1,400.00$ 1,400.00$ - 14" x 8" Tee 2 EA 1,400.00$ 2,800.00$ - 14" x 12" Reducer 1 EA 1,500.00$ 1,500.00$ - 14" x 14" Tee 1 EA 1,600.00$ 1,600.00$ - 8" 45 Degree Bend 11 EA 1,800.00$ 19,800.00$ - 8" 90 Degree Bend 1 EA 2,500.00$ 2,500.00$ - 12" 45 Degree Bend 2 EA 2,500.00$ 5,000.00$ - 14" 22.5 Degree Bend 2 EA 2,800.00$ 5,600.00$ - 14" 45 Degree Bend 6 EA 2,800.00$ 16,800.00$ - 8" Gate Valve 3 EA 8,500.00$ 25,500.00$ - 12" Gate Valve 1 EA 10,000.00$ 10,000.00$ 7141118 38" x 60" RCEP (Class III) 2,402 LF 900.00$ 2,161,800.00$ 7191205 Catch Basin - Type 9 2 EA 10,000.00$ 20,000.00$ 7192020 Drop Inlet (24" x 36") 21 EA 8,000.00$ 168,000.00$ 7192105 Manhole 1 EA 12,000.00$ 12,000.00$ 7192110 Junction Box 2 EA 10,000.00$ 20,000.00$ 7204100 Concrete Sidewalk 144 SY 100.00$ 14,400.00$ 7204900 Detectable Warning Material 20 SF 40.00$ 800.00$ 7205000 Concrete Driveway 595 SY 150.00$ 89,250.00$ 8041020 Rip Rap (Class B) 80 TON 200.00$ 16,000.00$ 8048205 Geotextile for Erosion Control Under Riprap (Class 2) Type B 110 SY 40.00$ 4,400.00$ 8131000 Sodding 22.4 MSY 12,000.00$ 268,800.00$ - Misc. Erosion Control/Water Management 1 LS 75,000.00$ SUBTOTAL 4,666,227.22$ Contingency at 10.0 % 466,623.00$ 466,623.00$ GRAND TOTAL OPINION OF CONSTRUCTION COST $5,132,900 (Other) QUANTITY COST OPINION OF PROBABLE CONSTRUCTION COST DATE PREPARED : 07/15/2025 BASIS FOR ESTIMATE (No design completed-Master Plan) (Preliminary design - 50% Design Level) (Final design - 95% level) OPINION OF PROBABLE CONSTRUCTION COST Since the Engineer has no control over the cost of labor, materials, equipment, over the Contractor's methods of determining prices, or over competitive bidding or market conditions, the Opinions of Probable Construction Costs provided for herein are made on the basis of his experience and qualifications. These opinions represent his best judgment as a design professional familiar with the construction industry. However, the Engineer cannot and does not guarantee that proposals, bids, or the construction cost will not vary from Opinions of Probable Construction Costs prepared by him. Thomas & Hutton Sheet 1 of 1 65 RFP 2026.08 AV Live-streaming Equipment INA Display PMC Audio Visual Portside Technology Sharp Business Systems 66 City of Isle of Palms, South Carolina Request for Proposals (RFP) 2026-08 Audio Visual Design and Implementation Services In compliance with the City of Isle of Palms procurement ordinances, the City is requesting proposals from qualified vendors to design and implement audio visual technology in the City Hall Council Chambers. The request will be awarded pursuant to the City’s procurement ordinance. The City reserves the right to reject any and all proposals and to waive irregularities. Project Overview The City of Isle of Palms desires to modernize and upgrade Council Chambers with the latest Audio Visual (AV) technology, including but not limited to new 4K cameras, livestreaming equipment, microphones, displays, speakers, and real-time captioning. The City is looking for a qualified vendor to provide professional services for this effort by designing and implementing upgrades to enhance the quality of the audio, visual, captioning and livestreaming capabilities. The system should balance the latest AV technology with ease of use for when primary AV staff are absent. The current quality of our streams can be viewed on YouTube: www.youtube.com/@CityofIsleofPalmsLivestream Existing Equipment: The City currently has the following equipment installed in Council Chambers which may be reused: • Fourteen (14) gooseneck microphones • One (1) wireless microphone • Two (2) flat-panel TVs • Cabinet for housing racks of equipment The City is open to either reusing or replacing existing equipment based on the vendor's proposed design and recommendations. The City does not require reuse of any existing equipment if new equipment is necessary to meet the functional requirements of this RFP. City Provided Equipment: • Apple Mac Studio: M4 Max, Four Thunderbolt 5 (USB-C) ports, Two USB-A ports; Two USB-C ports • A 300mbps+ upload and download fiber internet connection 67 Room Arrangements: (1) Council meeting layout (2) Committee meeting layout Traditional dais arrangement Round Table Arrangement Mandatory Requirements: • Four (4) or more permanently installed 4K pan, tilt, and optical zoom cameras • Camera coverage of councilmembers, public comment podium, wide room view, and multiple angles for round-table discussions. • Professional production capabilities and video switching between camera angles, presentation content, remote meetings, and meeting start, recess, and adjournment screens. • System should facilitate remote meeting participants (Zoom/Teams/etc.) to show on the livestream and display in the council chamber • Install necessary cabling for all audio/video work that is hidden or minimally visible • Ability to overlay graphics including lower-thirds, meeting titles, and City branding. • Provide hands on training of all AV technology installed • Provide documentation on network setup, passwords and access information, and instructions on how to use all equipment Accessibility Requirements • Real time closed captions with four (4) seconds or less latency. • Captions must be viewer-selectable and not permanently burned into the video. • Caption functionality during YouTube livestreams. • Vendors shall disclose caption accuracy, hardware/cloud subscription costs, licensing requirements. • Ability to live stream 4K video quality 68 System Architecture Diagram Requirement Each proposal shall include a detailed system architecture diagram illustrating cameras, audio systems, video switching, cable connection and feed types, captioning workflow, remote meeting integration, network connectivity, and YouTube streaming workflows. Signal flow and system responsibilities shall be clearly identified. Proposal Evaluation Criteria • Experience in similar installations • Adherence to best practices to yield a professional, high quality, reliable, and neat AV installation • References for similar installations • Timeline for completion of project and proposed downtime • Cost • On-going support, training and availability for support 24/7 Proposal Requirements • The contractor must provide documentation articulating their qualifications, and how many years of experience they have in the area of AV design and implementation. • The Contractor shall provide a detailed pricing breakdown of all designs and installation services. • Warranty o Labor: Provide a 12-month labor guarantee of all shop and field fabricated components and all QSYS control functionality. This includes the labor to remove and replace any/all defective audio, power or video cabling. o Materials: Provide a 12-month warranty of all small components i.e. cables, connectors, stands, custom fabricated products. All other audio, power and video components are covered by each respective manufacturer’s warranty and subject to their implicit terms. o Provide any software maintenance agreements or warranty information o Provide information on any manufacturer or third party hardware warranties • Provide all system passwords and admin access information 69 Deadline for Questions The deadline for questions is August 13, 2026. Proposers should send questions regarding this Request for Proposals to Joshua Uys, Public Information Officer, in writing by email to juys@isleofpalms.gov. Questions received before this deadline will be answered via addendum posted on the City’s website at www.isleofpalms.gov/requests-bids-proposals. If an addendum is issued, proposers must acknowledge receipt of the addendum with their proposal. Questions received after this deadline will not be answered. By submitting a proposal, proposers attest that they have read the “Agreement” that is included in this Request for Proposals and are prepared to execute these documents should they be the successful proposer. Deadline for Submission Deadline for submission is 12pm on August 27, 2026. Submissions must be received at 1207 Palm Boulevard, Isle of Palms, South Carolina 29451 in a sealed envelope, where they will be opened and read aloud. Sealed envelopes must be clearly marked RFP 2021-03“Audio Visual Design and Implementation Services” and include one (1) hard copy and one (1) electronic copy in PDF format. The City accepts no responsibility for electronic submissions, and it will be the responsibility of the proposers to verify receipt by the City. Proposals may be delivered by hand or by mail, but no proposal shall be considered which is not actually received by the City at the place, date and time appointed by the City and the City shall not be responsible for any failure, misdirection, delay or error resulting from the selection by any proposer of any particular means of delivery of Proposals. If an addendum is issued, proposers must acknowledge receipt of the addendum with their Proposals. Proposers acknowledge and agree that the City will not be liable for any costs, expenses, losses, damages (including damages for loss of anticipated profit) or liabilities incurred by the respondent or any member of the respondent’s organization as a result of, or arising out of, submitting a proposal, negotiating changes to such proposal, or due to the City’s acceptance or non-acceptance of the proposal or the rejection of any and all Proposals. Respondents are responsible for submission of accurate, adequate and clear descriptions of the information requests. Neither issuance of the RFP, preparation and submission of a response, nor the subsequent receipt and evaluation of any response by the City of Isle of Palms will commit the City to award a contract to any respondent even if all the requirements in the RFP have been met. By signing its proposal, Proposer certifies that it will comply with the applicable requirements of Title 8, Chapter 14 of the South Carolina Code of Laws and agrees to provide to the City upon request any documentation required to establish either: (a) that Title 8, Chapter 14 is inapplicable both to Proposer and its subcontractors or sub-subcontractors; or (b) that Proposer and its subcontractors or sub-subcontractors are in compliance with Title 8, Chapter 14. Pursuant to Section 8-14-60, "A person who knowingly makes or files any false, fictitious, or fraudulent document, statement, or report pursuant to this chapter is guilty of a felony, and, upon conviction, must be fined within the discretion of the court or imprisoned for not more than five 70 years, or both." Proposer agrees to include in any contracts with its subcontractors language requiring its subcontractors to (a) comply with the applicable requirements of Title 8, Chapter 14, and (b) include in their contracts with the sub-subcontractors language requiring the sub- subcontractors to comply with the applicable requirements of Title 8, Chapter 14. If the Proposer is a corporation, state your correct corporate name and State of incorporation. If Proposer is a partnership, state names and addresses of partners. If Proposer is a trust or other legal entity, state correct names and addresses of trustees or names and address of those legally authorized to proposal and enter into contracts. 71 RFP 2026.09 IT Managed Technology Services AAIT Asset Technology Group Automate IT Cantey Tech Consulting CMIT Solutions Consultaad Public Services Corsica Technologies CyberGarde Golden Five Interdev Katalyst Merit Technologies Nano Defense NetCertPRO (Network Certified Professionals) Novatech Portside Technology SNS Technologies SoftSages Tretek Systems VC3 WeldonPC 72 Evaluation Criteria RFP 2026.09 SCORING. All evaluation criteria will be scored on a scale of 0 to 4. [1] A score of zero (0) is rated as Unsatisfactory or Non-Responsive. The proposal fails to address the requirement, does not meet the minimum requirement, or the information provided is insufficient to evaluate. [2] A score of one (1) is rated as Marginal. The proposal minimally addresses the requirement. Significant deficiencies, unanswered questions, or concerns exist that could affect successful performance. Presents high implementation risk. [3] A score of three (3) is rated as Partially Meets Requirements. The proposal generally addresses the requirement but contains notable weaknesses, omissions, or areas requiring clarification. Presents some implementation risk. [4] A score of four (4) is rated as Exceptional. The proposal fully meets or exceeds the City's requirements. Response is comprehensive, demonstrates a clear understanding of the City's needs, presents minimal risk, and provides significant added value or innovation. Each individual criterion has an assigned weight. The base score will be multiplied by the weighting factor to determine that criterion’s total score. See below. WEIGHTING. There are seven (7) evaluation criteria listed from A-G on pages six through seven of the RFP. The weight for each of the criteria is as follows: -Understanding the City’s Needs. Weight of one (1) -Qualifications and Experience. Weight of one (1) -Technical Approach. Weight of three (3) -Strategic Advisory Services. Weight of one (1) -Operational Support. Weight of one (1) -Pricing. Weight of two (2) -References. Weight of one (1) 73 City of Isle of Palms Request for Proposals (RFP 2026-09) “Managed Technology Services” Requirement. The City of Isle of Palms ("City") is requesting proposals from qualified firms to provide comprehensive managed technology services that support the City's municipal day-to- day and crisis response operations, enhance cybersecurity, improve organizational resilience, and assist City leadership in making informed technology decisions. The City seeks a long-term technology partner rather than a traditional managed services provider. While dependable technical support remains essential, the City also seeks a partner that understands municipal government, assists executive leadership with planning, budgeting, procurement, cybersecurity, and technology decision-making. Moreover, this partner participates in operational and emergency planning as needed and provides proactive recommendations that improve organizational effectiveness and resilience. The City is seeking a right-sized approach in which it pays a predictable fee for routine operational support while retaining the flexibility to procure additional professional services, when needed, through clearly defined and transparent pricing and service level agreements. The successful proposer shall demonstrate the ability to deliver reliable technical support, proactive technology management, sound strategic guidance and roadmaps that continuously improve the City's technology environment while balancing operational effectiveness, cybersecurity, fiscal responsibility, optimization and long-term sustainability. Background. The City of Isle of Palms is a full-service coastal municipality serving approximately 4,500 residents and a substantially larger seasonal population. City operations include Police, Fire, Public Works, Recreation, Building, Administration, Finance, Municipal Court, and other municipal services. As a coastal community, the City is subject to natural disasters such as hurricanes which create operational challenges in planning for and executing continuity of operations of which IT is essential. Technology plays a critical role in nearly every City function, including public safety communications, financial management, permitting, public works operations, citizen services, emergency response, and continuity of government. The City currently operates multiple municipal facilities connected through a managed network environment utilizing Microsoft technologies, virtualization, cloud services, public safety applications, and numerous third-party business systems. The City's objective is not simply to maintain this environment but to continually improve and optimize it through thoughtful planning, sound fiscal stewardship, disciplined cybersecurity practices, and dependable but right-sized operational support. Desired Relationship. The City desires a technology partner that becomes familiar with its organization, understands departmental operations, anticipates technology needs, and participates in planning rather than simply responding to service requests. The City values firms 74 that communicate candidly, identify opportunities for improvement, and provide recommendations that support informed executive decision-making. Current Technology Environment The following information is provided solely to assist proposers in preparing realistic proposals. The City's primary legacy technology environment includes Microsoft 365, Hyper-V virtualization, public safety systems, enterprise financial software, cloud services, and multiple third-party municipal applications. • 103 full-time employees • Approximately 125 Microsoft 365 users • Mix of Exchange Online Plans 1 and 2 with 137 total licenses • 90 workstations • 9 servers (2 being virtual) • 8 multi-function networked printers • Multiple additional items classified as network “gear” • 1 business class backup device • 2 firewalls • Fiber/ internet provided by Segra • Payroll, permitting, and accounting provided by BS&A Software • Myriad additional software and services such as: Axon, Diverse (NCIC access), Geothinq, iWorks, Image Trend, Power DMS, and others The successful proposer should assume responsibility for supporting the City's existing technology environment while recommending thoughtful modernization where appropriate. SCOPE OF WORK AND SERVICES The following descriptions identify minimum service expectations. Proposers should clearly identify services included within the base monthly fee and distinguish those requiring additional authorization or project pricing. Base Monthly Support • Unlimited help desk support (remote, phone, and onsite as required) for approximately 50 managed users and 82 email-only users • Business-hours support with emergency after-hours response for critical incidents • Network operations including monitoring, maintenance, firmware updates, configuration backup, and administration of switches, routers, firewalls, wireless infrastructure, Internet connectivity, and patch management • Following initial procurement, conduct maintenance and management of all Microsoft licensing • Server administration including preventative maintenance, configuration management, monitoring, operating system patching, storage management, virtualization support, and backup monitoring 75 • Maintain an accurate and current inventory of the City's technology assets, including identification of active and inactive assets • Cybersecurity operations including endpoint detection and response (EDR), security monitoring, vulnerability detection and remediation, MFA administration, email protection, phishing response, and security event monitoring • Microsoft 365 administration including Exchange Online, Teams, SharePoint, OneDrive, license management, and Entra ID routine administration • Backup and disaster recovery monitoring, including periodic restore testing and an annual disaster recovery exercise • Routine vendor coordination with third-party software, internet, telecommunications, and hardware providers for incident resolution • Develop and maintain current documentation of the City's technology environment, including network diagrams, system configurations, administrative credentials, backup procedures, and recovery documentation • Software and hardware recommendations with immediate operational impacts • Provide operational support before, during, and after significant events such as hurricanes • Standard monthly reporting: o Open and closed ticket summary o Average response and resolution times o Patch compliance status o Backup success/failure status o Critical vulnerabilities and remediation actions o Major incidents and root causes o Asset inventory updates o Recommendations for operational improvements • Quarterly Operational Review at the executive level covering trends, recurring operational issues, infrastructure health, cybersecurity events, asset lifecycle concerns Professional Services (Outside Base Monthly Support) • Annual Strategic Planning: o Technology roadmap development / “Greenfield” look o Network redesign or architecture changes o Budget planning/ forecasting o Capital planning and replacement planning recommendations o Asset portfolio assessments to ensure City is right-sized, based on usage • Major projects, implementations, migrations, and new system deployments • Extended on-site operational support during declared emergencies, prolonged Emergency Operations Center activations, or multi-day disaster response operations beyond the base support services • Server replacements or infrastructure refresh projects, as needed • Wireless redesign or expansion projects • ERP or enterprise application implementations • Enterprise level security assessments, penetration testing, or vCISO services 76 • SharePoint development, workflow automation, and data conversions • Procurement consulting and preparation of specifications unless specifically requested by the City Modular Options/ Features The City recognizes that technology needs evolve rapidly. Accordingly, a successful proposer will have the ability to scale technology services, including adding, modifying, or removing technology services, without requiring replacement of the entire agreement. Potential add on services include but are not limited to: • All services in the preceding section above • Telecommunications • GIS support • Website management • Cloud services • Public safety technology • Additional facilities • Additional users • Other mutually agreed technology services PROPOSAL CONTENTS AND SUBMITTAL INSTRUCTIONS Consistent with Chapter 10 Purchasing Procedures, Section 1-10-5 Methods of Source Selection, of the city code, the City is requesting information that speaks to a firm’s track record of “professional and technical qualifications” and “demonstrated competence and qualification.” By 10:00 AM on Friday August 28, 2026 please provide a hard copy proposal by courier or mail to: P hysical Address Instructions (Delivery by Courier, Mail Service (FEDEX, etc)): C/o Douglas Kerr City Administrator City of Isle of Palms 1207 Palm Boulevard Isle of Palms, South Carolina 29451 Mailing Instructions (US Mail): C/o Douglas Kerr City Administrator City of Isle of Palms Post Office Box 508 Isle of Palms, South Carolina 29451 PROPOSAL REQUIREMENTS The proposal should demonstrate the firm's understanding of municipal government and clearly explain how the proposed services satisfy the City's objectives. 77 The narrative portion of the Proposals should not be more than ten pages. At a minimum, proposals shall include/ address the following areas: 1. Cover Letter Introduce the firm, summarize the firm's understanding of the City's objectives, and identify the individual authorized to negotiate on behalf of the proposer. 2. Firm Qualifications Describe: • Years in business • Office locations • Number of employees • Municipal experience • South Carolina experience • Experience supporting organizations of similar size and complexity 3. Understanding of the City's Needs Rather than simply describing services, proposers should explain their understanding of the City's operating environment and philosophy as described in this RFP. The City is particularly interested in understanding how the proposer approaches long-term client relationships, strategic planning, operational support, cybersecurity, and technology leadership. 4. Proposed Service Delivery Describe how services will be delivered including: • Transition of current services/ data and new service implementation • Help Desk operations • On-site support • Remote support • Assigned personnel • Escalation procedures • After-hours support • Emergency response • Cybersecurity services • Strategic advisory services 5. Strategic Advisory Approach Describe how your firm assists executive leadership with: • Technology planning • Budget preparation • Lifecycle and capital planning • Cybersecurity governance • Risk management • Cost optimization 6. Emergency Operations Support 78 Describe how your firm supports clients during: • Hurricanes/ severe weather events • Cyber incidents • Significant outages • Emergency Operations Center activation Include expected response capabilities and availability of senior technical personnel. 7. References Provide at least five references from organizations of similar size. 8. Detailed Pricing Proposal. • Base managed services fee • Per managed user fee • Per email only user fee • Hourly rates for projects, engineering, consulting, project management, travel, after- hours support, and security consulting • Pricing assumptions and any annual escalation provisions • Identify any assumptions that materially affect the proposed pricing EVALUATION PROCESS AND CRITERIA The City's objective is to select the firm that provides the greatest overall value to the organization while demonstrating technical competence, operational understanding, financial responsibility, and a commitment to long-term partnership. The City reserves the right to reject any or all proposals, waive minor irregularities, request additional information, interview proposers, negotiate modifications, or cancel this solicitation if determined to be in the City's best interest. Proposals will be evaluated using, at minimum, the following criteria. A. Understanding of the City's Needs The proposer's understanding of the City's operational environment, organizational objectives, and philosophy of services. The City will evaluate the extent to which the proposal demonstrates an understanding of municipal government operations rather than merely describing generic managed technology services. B. Qualifications and Experience The firm's experience supporting organizations of similar size and complexity, particularly municipalities and public safety agencies. Consideration may include: • Years in business • Technical certifications • Relevant experience 79 • Staff qualifications • Organizational stability C. Technical Approach The quality and completeness of the proposed technical solution including: • Infrastructure support • Cybersecurity • Help Desk • Network administration • Disaster recovery • Documentation • Technology planning • Ability to scale and make any future contract vehicle “modular” D. Strategic Advisory Services The City places significant value on a firm's ability to assist executive leadership through high level strategic planning from inception to at least three years out, technology planning, budgeting, lifecycle management, procurement assistance, executive reporting, operational planning, and organizational improvement. E. Operational Support The City's technology partner should understand that technology supports municipal operations. The proposal should demonstrate an ability to support the City during routine operations as well as major incidents, emergency response, continuity of government activities, and significant community events. F. Pricing Cost savings is a major factor in this RFP and the City will preference proposers with dedicated processes that illustrate a bias toward cost optimization. Additional consideration may include: • Overall value • Pricing transparency and clarity • Long-term affordability • Cost predictability • Optional service pricing G. References The City may contact references and consider prior performance, responsiveness, professionalism, communication, and overall client satisfaction. Deadline for Submissions: The deadline for submission is 10:00 AM Friday August, 28 2026. Proposals will be received by mail or courier (see above) in a sealed envelope. Sealed envelopes must be clearly marked “RFP 2026-09 – Managed Technology Services” and include one (1) hard copy. 80 The deadline for questions is 5:00 PM, Friday August, 14 2026. Questions will be answered in addendum format and posted on the City’s RFP tab on the City’s webpage. Site visits are encouraged. To coordinate a visit please contact the Deputy City Administrator, Sean Kuester at skuester@isleofpalms.gov or at 843-886-6428. All visits must be complete no later than Friday August 14, 2026. I t will be the responsibility of the proposers to verify receipt by the City. Proposals may be delivered by hand or by mail, but no proposal shall be considered which is not actually received by the City at the place, date and time appointed by the City and the City shall not be responsible for any failure, misdirection, delay or error resulting from the selection by any proposer of any means of delivery. All proposals submitted shall include a current e-mail address. Proprietary and/or Confidential Information: Your proposal is a public document under the South Carolina Freedom of Information Act (FOIA), except as to information that may be treated as confidential as an exception to disclosure under the FOIA as determined by the City. If you cannot agree to this standard, please do not submit your proposal. All information that is to be treated as confidential and/or proprietary must be clearly identified, and each page containing confidential and/or proprietary information, in whole or in part, must be stamped and/or denoted as CONFIDENTIAL, in bold, in a font of at least 12-point type, in the upper right-hand corner of the page. All information not so denoted and identified will be subject to disclosure by the City. Proposers acknowledge and agree that the City will not be liable for any costs, expenses, losses, damages (including damages for loss of anticipated profit) or liabilities incurred by the respondent or any member of the respondent’s organization as a result of, or arising out of, submitting a proposal, negotiating changes, or due to the City’s acceptance or non-acceptance of the proposal or the rejection of any and all proposals. Proposers are responsible for submission of accurate, adequate and clear descriptions of the information requests. Neither issuance of the RFP, preparation and submission of a response, nor the subsequent receipt and evaluation of any response by the City of Isle of Palms will commit the City to award a contract to any respondent even if all the requirements in the RFP have been met. Proposers must have or be able to procure an Isle of Palms Business License. 81 QUOTE 2026 Ford Ranger STX 4x4 Santee Automotive LLC 2601 Paxville Highway Manning, South Carolina 29102 United States Phone: 1-888-853-5338 Fax: 1-888-853-5338 info@santeefleet.com BILL TO City of Isle of Palms Douglas Kerr 1027 Palm Boulevard Isle of Palms, South Carolina 29451 United States (843)886-6428 dkerr@isleofpalms.gov Estimate Number: 16490 Customer Ref: State Contract # 4400035151 Estimate Date: August 27, 2026 Valid Until: October 26, 2026 Grand Total (USD): $37,686.00 Units Quantity Price Amount Ford Ranger State Contract # 4400035151 1 $36,771.00 $36,771.00 2026 Ford Ranger SXT 4x4 Model Code R4P XL Series 100A Equipment Package STX Appearance Package 2.3 L EcoBoost Engine 10 Speed Auto Transmission 3.73 Locking RR Axle Ebony Cloth Bucket Seats Rear Cloth Bench Seat Carpet Flooring with Floor Mats Power Windows & Door Locks Power Glass, Manual Folding Sideview Mirrors Halogen Fog Lamps 17" Black Steel Wheels 255/70 R17 A/T Tires Spare Tire (Full Sized) Black Running Boards Trailer Tow Package Integrated Trailer Brake Controller Class IV Receiver Hitch with 4 & 7 Pin Wiring Ford Ranger Standard Features 1 $0.00 $0.00 FORD CO-PILOT360 TECHNOLOGY ● Headlamps – Autolamp (Automatic On/Off) ● Auto High-Beam Headlamps Page 1 of 3 for Quote #16490 82 Units Quantity Price Amount ● Pre-Collision Assist with Automatic Emergency Braking ● Analog Rear View Camera ● Cruise Control ● Lane Keeping Aid ● Post-Collision Braking FUNCTIONAL ● Remote Keyless-Entry w/Remote Tailgate Lock ● AM/FM stereo and Six (6) Speakers ● Extended Service Interval Monitor ● FordPass Connect ● USB Ports – A & C ● SYNC 4A — Enhanced Voice Recognition Communications and Entertainment System — 10” Touchscreen in Center Stack with Swipe Capability — Applink — 911 Assist — Apple CarPlay and Android Auto Compatibility Exterior Color Carbonized Gray Metallic 1 $0.00 $0.00 Oxford White Shadow Black Premium Paints: Ruby Red metallic Tri-Coat Marsh Gray Desert Sand Velocity Blue Metallic 3rd Key Fob Third Key Fob 1 $415.00 $415.00 Page 2 of 3 for Quote #16490 QUOTE 2026 Ford Ranger STX 4x4 Santee Automotive LLC 2601 Paxville Highway Manning, South Carolina 29102 United States Phone: 1-888-853-5338 Fax: 1-888-853-5338 info@santeefleet.com 83 Units Quantity Price Amount Vehicle Delivery $15.00 Delivery Fee Plus $1.50 Per Mile 1 $0.00 $0.00 Vehicle Sales Tax South Carolina Vehicle Sales Tax/Infrastructure Maintenance Fee 1 $500.00 $500.00 Grand Total (USD): $37,686.00 Notes / Terms State Contract # 4400035151 Saved Order A001 Page 3 of 3 for Quote #16490 QUOTE 2026 Ford Ranger STX 4x4 Santee Automotive LLC 2601 Paxville Highway Manning, South Carolina 29102 United States Phone: 1-888-853-5338 Fax: 1-888-853-5338 info@santeefleet.com 84

Source: City of Isle of Palms website. First collected Oct 13, 2026.