Agenda
Town of James Island · Charleston County · meeting of Apr 9, 2026 · Agenda packets
Open the original document More from Town of James Island
Text
Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.
April 9, 2026
5:00 PM
NOTICE OF THIS MEETING WAS POSTED IN ACCORDANCE WITH THE FREEDOM OF INFORMATION ACT
This meeting will be live streamed on the Town’s website:
jamesislandsc.us
Public Comments need to be received via email by noon on Wednesday 4/8/2026 to
kcrane@jamesislandsc.us
I. CALL TO ORDER
II. PRAYER AND PLEDGE
III. COMPLIANCE WITH THE FREEDOM OF INFORMATION ACT
IV. INTRODUCTIONS
V. APPROVAL OF OCTOBER 9, 2025 MINUTES
VI. PUBLIC COMMENTS
VII. ZONING MAP AMENDMENT:
a. Case #ZRSM-2-26-016
Request to rezone property located at 1114 Jeffery Drive from the Low-Density Single Family
Residential (RSL) Zoning District to the Moderate-Density Suburban Residential (RSM) Zoning
District
(TMS #428-03-00-006)
Planning Commission will vote on a recommendation to Town Council.
VIII. PROPOSED AMENDMENTS TO THE TOWN OF JAMES ISLAND ZONING AND LAND
DEVELOPMENT REGULATIONS ORDINANCE (ZLDR) INCLUDING:
a. DEFINITIONS (153.013): Adding definitions for pet washing stations, pet shelters, and clarifying pet
store definition
b. ANIMAL SERVICES (153.152): Adding wording and conditions to animal service uses
c. USE TABLE (Table 153.110): Adding pet washing stations and pet shelters to table, and
corresponding use categories
d. BOARD OF ZONING APPEALS (153.027): Adding wording to allow for variances and appeals of
administrative decisions concerning the Flood Damage Prevention Ordinance and the Town
Building Regulations Ordinance to be heard by the Board of Zoning Appeals
(See attached packet, only highlighted sections in Chapter 153 are up for consideration;
Planning Commission will vote on a recommendation to Town Council.)
IX. ELECTION OF PLANNING COMMISSION OFFICERS: CHAIR & VICE-CHAIR
X. CHAIR'S COMMENTS
XI. COMMISSIONERS COMMENTS
XII. NEXT SCHEDULED MEETING DATE: MAY 14, 2026
XIII. ADJOURN
JAMES ISLAND PLANNING COMMISSION
MEETING AGENDA
1122 Dills Bluff Road, James Island, SC 29412
1
TOWN OF JAMES ISLAND PLANNING COMMISSION:
April 9, 2026
Case Summary: ZRSM-2-26-016
Request to rezone from the Low-Density Suburban Residential (RSL)
Zoning District to the Moderate-Density Suburban Residential (RSM)
Zoning District
History and Overview:
1114 Jeffery Drive is located near the corner of Lemontree Lane and Jeffery Drive
and is one block from Camp Rd. The parcel currently has one home located on it
and the rest of the property is wooded . The parcel included in the Zoning Map
Amendment Request is 0. 93 acres in size and is in the RSL Zoning District. The
parcel is considered a legal conforming lot.
The applicant and owner (Jonathan Schumacher) is seeking to rezone the parcel
from the RSL Zoning District to the RSM Zoning District to allow for a density that
may permit three dw elling units, due to the lot size bein g slightly less than one
acre. Maximum density in the RSL Zoning District is 3 dwelling units per acre, while
the maximum density in the RSM Zoning District is 4 units per acre. The applicant
“believes that RSM more accurately reflects the historical character of this
neighborhood.”
Adjacent Zoning:
Surrounding properties to the south and west are in the RSL Zoning District in the
Town of James Island and are residentially utilized. Property to the north is also in
the RSL Zoning District, is owned by First Baptist Church a nd is used as an
overflow parking lot. Property to the east is owned by Storer Cable of Carolina, is
zoned SR-1 in the City of Charleston and has a cell tower located on it. Other uses
within 300’ are mostly residential but also include a church and parks/recreation.
Approval Criteria:
According to Section §153.043 of the Zoning and Land Development Regulations
Ordinance (ZLDR), applications for Zoning Map Amendment (Re-zoning)
approval may be approved only if Town Council determines that the following
criteria are met:
1. The proposed amendment is consistent with the Comprehensive Plan
and the stated purposes of this Ordinance;
ZONING/PLANNING
DEPARTMENT
2
Staff’s response: The proposed zoning map amendment is consistent with
the intent of the Comprehensive Plan, specifically the Land Use Element
Goal which states the Town will, “ encourage the orderly and
environmentally sound development of the land with special consideration
to maintaining the suburban character and natural ecosystems of the area.”.
Additionally, the Purpose and Intent of the Zoning Ordinance states the
chapters are intended to assure, in general “the wise and timely
development of new areas, and redevelop ment of previously developed
areas in harmony with the Comprehensive Plan”, amongst other purposes
and intents.
2. The proposed amendment will allow development that is compatible
with existing uses and zoning of nearby property;
Staff’s response: The applicant’s letter of intent states that “the surrounding
neighborhood already functions at densities that exceed both the RSL and
RSM maximums. The current RSL zoning is a poor match for the reality of
this area. RSM is a most appropriate and accurate zoning classification .”
Additionally, the applicant maintains that “both districts allow identical uses
and maintain the same front setback (25 feet), side setback (10 feet), and
maximum height (35 feet) .” The proposed amend ment will allow the
property to retain its residential character and the residential use capability
will also be retained.
3. The Town and other service providers will be able to provide adequate
water and sewer supply, storm water facilities, waste disposal and
other public facilities and services to the subject property, while
maintaining adequate levels of service to existing development;
Staff’s response: The subject property has previously been serviced by
public facilities and the Town and other service providers will be able to
continue these public facilities and services while maintaining adequate
levels of service to existing development.
4. The applicant provides documentation that the proposed amendment
will not result in significant adverse impacts on other property in the
vicinity of the subject tract or on the environment, including air, water,
noise, storm water management, traffic conge stion, wildlife and
natural resources; and
Staff’s response: The proposed amendment should not result in significant
adverse impacts on other property in the vicinity or on the environment as
the applicant explains, “RSM does not intro duce densities that are foreign
to this area; it adopts a classification that is closer to what already exists on
the ground.”.
5. The subject property is suitable for proposed zoning classification
considering such things as parcel size, parcel configuration, road
access and the presence of resources and amenities.
Staff’s response: The subject property is a legal conforming lot in its current
zoning designation of RSL. The property also meets the minimum standards
for a Moderate-Density Suburban Residential (RSM) zoning designation
including parcel size and parcel configuration. There is direct access from
3
Jeffery Drive and it is suitable for the proposed zoning c lassification
because it will retain its residential compatibility with neighboring properties.
Planning Commission Meeting: April 9, 2026
Recommendation: TBD
Town Council Meetings: Public Hearing and 1st reading on May 21, 2026
2nd Reading on June 18, 2026
4/1/2026
1
1114 Jeffery Dr.
Adjacent Property
6
7
4/1/2026
2
Jeffery Drive
8
SUPPORTING STATEMENT FOR REZONING APPLICATION
1114 Jeffrey Drive, James Island, SC 29412 TMS# 428-03-00-006 | RSL → RSM | 0.93 Acres Applicant: John Schumacher February 2026
Overview of Request
This document provides the supporting arguments for the rezoning of the property at 1114 Jeffrey Drive
(TMS#
428-03-00-006)
from
RSL
(Low-Density
Suburban
Residential)
to
RSM
(Moderate-Density
Suburban
Residential).
The
applicant,
John
Schumacher,
believes
that
RSM
more
accurately
reflects
the
historical
character
of
this
neighborhood.
The RSL district permits a maximum of 3 dwelling units per acre. The RSM district permits a maximum of 4
dwelling
units
per
acre.
Both
districts
allow
identical
uses
and
maintain
the
same
front
setback
(25
feet),
side
setback
(10
feet),
and
maximum
height
(35
feet).
RSM
allows
a
slightly
reduced
rear
setback
(10
feet
versus
15
feet),
modestly
higher
building
coverage
(35%
versus
30%),
and
a
narrower
minimum
lot
width
(40
feet
versus
60
feet).
As the data in this statement demonstrates, the surrounding neighborhood already functions at densities that
exceed
both
the
RSL
and
RSM
maximums.
The
current
RSL
zoning
is
a
poor
match
for
the
reality
of
this
area.
RSM
is
a
most
appropriate
and
accurate
zoning
classification.
Neighborhood Analysis
The justification for this rezoning is empirical: the neighborhood surrounding the subject property already
operates
at
densities
that
exceed
what
the
RSM
district
would
permit.
The
applicant
conducted
an
analysis
of
all
developed
parcels
within
500
feet
of
the
center
of
the
subject
property.
Key Findings
Metric Value
Total developed parcels within 500 ft 22
Average density per-parcel 5 units/acre
Approx. Feet from Subject Parcel Number Lot Size (ac) Dwelling Units Density (u/ac)
0 428-03-000-75 0.25 2 8.00
0 428-03-000-76 0.25 1 4.00
30 428-03-000-57 0.25 2 8.00
32 428-03-000-16 0.27 1 3.70
50 428-03-000-05 0.41 2 4.88
50 428-03-000-58 0.33 2 6.06
80 428-03-000-61 0.22 1 4.55
108 428-03-000-13 0.18 1 5.56
120 428-03-000-59 0.52 1 1.92
122 428-03-000-17 0.40 2 5.00
178 428-03-000-74 0.45 2 4.44
184 428-03-000-80 0.21 1 4.76
202 428-03-000-18 0.12 1 8.33
232 428-03-000-12 0.19 1 5.26
254 428-03-000-19 0.38 1 2.63
255 428-03-000-10 0.35 2 5.71
260 428-03-000-73 0.46 2 4.35
270 428-03-000-11 0.26 1 3.85
318 428-03-000-21 0.20 1 5.00
320 428-03-000-22 0.18 1 5.56
326 428-03-000-20 0.17 1 5.88
358 428-03-000-72 0.46 1 2.17
The subject parcel consists of 0.93 acres. Under RSM, a maximum of three dwelling units would be permitted,
resulting
in
a
density
of
3.22
units
per
acre
—
still
below
the
neighborhood
median
of
5
units
per
acre.
RSM
does
not
introduce
densities
that
are
foreign
to
this
area;
it
adopts
a
classification
that
is
closer
to
what
already
exists
on
the
ground.
Conclusion
The applicant respectfully asks the Planning Commission for a favorable recommendation and the Town
Council
for
approval
of
this
zoning
map
amendment.
Respectfully,
John Schumacher Owner, 1114 Jeffrey Drive TMS# 428-03-00-006
§ 153.013 DEFINITIONS
PET GROOMING SALONS/PET WASHING STATIONS. An establishment primarily
engaged in the grooming and/or washing of household pets.
PET, HOUSEHOLD. Domestic animals typically kept for company or enjoyment within
the home. HOUSEHOLD PETS shall include, but not be limited to, domestic cats,
domestic dogs, domestic ferrets, gerbils, guinea pigs, hamsters, domestic laboratory
mice, domestic rabbits, goldfish, canaries, and parrots.
PET STORE. An establishment primarily engaged in the retail sale of household pets
supplies and food. May also include the retail sales of household pets and
various animal services as an accessory use.
PET SHELTERS. An establishment primarily engaged in providing temporary
housing, care, and medical attention for lost, abandoned, surrendered, or abused
animals.
§ 153.152 RESERVED. ANIMAL SERVICES.
(A) In zoning districts subject to conditions (C), animal services shall have a
maximum floor area of 5,000 square feet or less; otherwise this use shall fall
under the special exception procedures of this chapter.
(B) In zoning districts subject to conditions (C), all activities and storage areas
associated with animal services must be conducted in completely enclosed
structures; otherwise this use shall fall under the special exception procedures of
this chapter.
(C) All animal service uses shall comply with the site plan review requirements
of this chapter.
Table 153.110
Zoning Districts
Condition
NRM-25 AG-5 AGR RSL RSM MHS OR OG CN CC I
Septic tank installation, cleaning, or
related services
S S
Solid waste combustors or
incinerators, including cogeneration
plants
S
Solid waste disposal facility S § 153.171
Waste collection services S
Waste transfer facilities S
COMMERCIAL USES
ACCOMMODATIONS
Bed and breakfast inns C C C C S S C C C C § 153.124
Hotels or motels S A A A
Rooming or boarding houses S A A
RV (recreational vehicle) parks or
campgrounds
S S S § 153.132
ANIMAL SERVICES
Kennel A A C § 153.174
Pet stores, grooming salons, or pet washing
stations
S C A § 153.152
Small animal boarding (enclosed
building)
A A S S A § 153.152
Veterinary services A A S S C C C A A § 153.152
Pet shelters A A A C C C A A § 153.152
CHAPTER 153: ZONING AND LAND DEVELOPMENT REGULATIONS
General Provisions
§ 153.027 BOARD OF ZONING APPEALS.
(A) Review authority. The Board of Zoning Appeals does not act in a review or
recommending capacity.
(B) Decision-making authority. The Board of Zoning Appeals shall have final decision-
making authority on the following matters:
(1) Special exceptions;
(2) Variances, including those described in Section 151.55 of the Flood
Damage Prevention Ordinance; and
(3) Adjustments as described in Section 150.14 of the Town Building
Regulations Ordinance; and
(43) Appeals of administrative decisions on:
(a) Zzoning-related matters as described in this Chapter;.
(b) Floodplain regulations-related matters, as described in Chapter 151 of the
Code of Ordinances; and
(a) Building regulations-related matters, as described in Chapter 150 of the Code
of Ordinances.
(C) Officers, rules, meetings, and minutes. Pursuant to S.C. Code § 6-29-790360, the
Board of Zoning Appeals shall elect one of its members as chair who shall serve for one
year or until re-election or a successor is elected and qualified. The Board of Zoning
Appeals shall adopt rules and procedures in accordance with the provisions of this chapter
not inconsistent with the provisions of S.C. Code Title 6, Chapter 29, as amended. The Board
of Zoning Appeals shall appoint a secretary. The secretary may be an employee of the town.
Meetings of the Board shall be at the call of the chair and at such other times as the Board
of Zoning Appeals may determine. Public notice of all meetings of the Board of Zoning
Appeals shall be provided by publication in a newspaper of general circulation in the town.
The Board of Zoning Appeals shall keep minutes of its proceedings, showing the vote of
each member upon each question or if absent or failing to vote. The Board of Zoning
Appeals shall maintain records of its examinations and official actions, all of which, upon
approval, shall be filed immediately in the office of the Zoning Administrator. Such records
shall be available for public review and inspection during normal business hours.
(D) Composition. The Board of Zoning Appeals shall consist of five members appointed
by the Town Council for terms of four years each; provided, however, that, of the initial
members of the Board of Zoning Appeals, three members shall be appointed for four-year
terms and two members shall be appointed for two-year terms. Members shall serve until
their successors are appointed and qualified. Any vacancy which may occur on the Board of
Zoning Appeals shall be filled by the Town Council appointing a successor to serve out the
un-expired term of the vacancy. In appointing members to the Board of Zoning Appeals, the
Town Council shall consider their professional expertise, knowledge of the community, and
concern for the future welfare of the total community and its citizens. All members of the
Board of Zoning Appeals shall reside within the municipal jurisdiction of the town. No
member of the Board of Zoning Appeals may hold an elected public office.
(Ord. 2012-06, § 2.3, passed 10-18-2012; Ord. 2012-21, passed 12-20-2012; Ord. 2014-01,
passed 2-20-2014)
FOR REFERENCE ONLY, NOT UP FOR PLANNING COMMISSION VOTE
CHAPTER 151: TOWN REGULATIONS CONCERNING FLOOD DAMAGE PREVENTION
Section
General Provisions
151.01 Statutory authorization
151.02 Findings of fact
151.03 Statement of purpose
151.04 Objectives
151.05 Definitions
151.06 Lands to which this chapter applies
151.07 Basis for establishing areas of special flood hazard
151.08 Warning; disclaimer of liability
151.09 Provisions cumulative
151.10 Severability
151.11 Abrogation and greater restrictions
151.12 Effective date; application
Administration
151.25 Designation of Building Official
151.26 Duties and responsibilities of the Building Official
151.27 Duties and responsibilities of the Planning and Zoning Official
151.28 Duties and responsibilities of the Public Works Official
Provisions for Flood Hazard Reduction
151.40 General standards
151.41 Specific standards in addition to general standards for unnumbered A zones, AE
zones
151.42 Standards for regulatory floodways
151.43 Standards for subdivision proposals and other development
Appeals and Variances
151.55 Appeal and variance procedures
FOR REFERENCE ONLY, NOT UP FOR PLANNING COMMISSION VOTE
Compliance for Proposed Real Estate Transactions
151.70 Provision for inspections
Nuisances
151.85 Nuisances within a special flood hazard area
151.99 Penalty
Editor’s note:
The regulations set forth in this chapter are those of Charleston County Ordinance 1838,
adopted by the county on January 20, 2015, which was adopted by the Ttown’s Ordinance
2016-14 on January 19, 2017, and Ord. 2020-11, passed 12-17-2020, and Ord. 2024-XX,
passed xx.
GENERAL PROVISIONS
§ 151.01 STATUTORY AUTHORIZATION.
The Legislature of the State of South Carolina has in Code of Laws, § 5-7-30,4-9-30(5),
delegated the responsibility to local governmental units to adopt regulations designed to
promote the public health, safety, and general welfare of its citizenry. Therefore, the Town
of James Island, does ordain these flood damage prevention and protection regulations.
(Ord. 2016-14, passed 1-19-2017)
§ 151.02 FINDINGS OF FACT.
(A) The flood hazard areas of the Town of James Island are subject to periodic
inundation which results in loss of life and property, health and safety hazards, disruption
of commerce and governmental services, extraordinary public expenditures for flood
protection and relief, and impairment of the tax base, all of which adversely affect the
public health, safety and general welfare.
(B) These flood losses are caused by the cumulative effect of obstructions in floodplains,
causing increases in flood heights and velocities, and by the occupancy in flood hazard
areas by uses vulnerable to floods or hazardous to other lands which are inadequately
elevated, flood proofed, or otherwise unprotected from flood damage.
(C) In order for owners of property located within the Town which is subject to periodic
inundation to obtain flood damage insurance through the National Flood Insurance
Program, the United States government, by statute and through regulations promulgated
FOR REFERENCE ONLY, NOT UP FOR PLANNING COMMISSION VOTE
by the Federal Emergency Management Agency (FEMA), requires that the Town enact
floodplain regulations designed to reduce the amount of potential flood losses.
(D) The Town has previously adopted various ordinances establishing regulations
related to the prevention of flood damage.
(E) Based on the findings set forth above, the Town finds it is in the public interest and a
benefit to the general health, safety, and welfare of the residents of the Town, to adopt an
ordinance revising and amending the Town’s flood damage prevention regulations.
(Ord. 2016-14, passed 1-19-2017)
§ 151.03 STATEMENT OF PURPOSE.
It is the purpose of this chapter to promote the public health, safety, and general welfare
and to minimize public and private losses due to flood conditions in specific areas by
provisions designed to:
(A) Restrict or prohibit uses which are dangerous to health, safety, and property due to
water or erosion hazards, or which result in damaging increases in erosion or in flood
heights or velocities;
(B) Require that structures vulnerable to floods, including appurtenant structures, be
protected against flood damage.
(Ord. 2016-14, passed 1-19-2017)
§ 151.04 OBJECTIVES.
The objectives of this chapter are:
(A) To protect human life and health;
(B) To minimize expenditure of public money for costly flood control projects;
(C) To minimize the need for rescue and relief efforts associated with flooding and
generally undertaken at the expense of the general public;
(D) To minimize prolonged business interruptions;
(E) To minimize damage to public facilities and utilities such as water and gas mains,
electric, telephone and sewer lines, street and bridges located in floodplains;
(F) To help maintain a stable tax base by providing for the sound use and development
of flood prone areas in such a manner as to minimize flood blight areas;
(G) To insure that potential homebuyers are notified that property is in a flood area;
(H) To provide protection to assets and infrastructure against sea level rise;
FOR REFERENCE ONLY, NOT UP FOR PLANNING COMMISSION VOTE
(I) To build resilience throughout the community to better respond to recurrent burdens
and sudden disasters;
(J) To increase property protection for all structures during flooding events due to
hurricane and rainwater flooding; and
(K) To protect the natural floodplain functions and capacity for flooding within the
community.
(Ord. 2016-14, passed 1-19-2017; Ord. 2020-11, passed 12-17-2020)
§ 151.05 DEFINITIONS.
For the purpose of this chapter, the following definitions shall apply unless the context
clearly indicates or requires a different meaning. Unless specifically defined below, words
or phrases used in this chapter shall be interpreted so as to give them the meaning they
have in common usage and to give this chapter its most reasonable application in light of its
stated objectives. Where it states “means” is the literal definition.
“A” -ZONE is areas subject to inundation by the 1% annual chance flood event. Because
detailed hydraulic analyses have not been performed, no Base Flood Elevations (BFEs) or
flood depths are shown.
“AE” ZONE are areas subject to inundation by the 1% annual chance flood event
determined by detailed methods. BFEs are shown within these zones.
ACCESSORY RESIDENTIAL STRUCTURE is a structure on the same parcel of property as
the principal structure, used for parking of vehicles or typical residential equipment, or for
limited storage. A SMALL ACCESSORY STRUCTURE is defined as one that has a footprint of
less than 120 square feet, and a LOW VALUE ACCESSORY STRUCTURE as one that has a
value of less than $1,000.
ADDITION (to an existing building) is an extension or increase in the floor area or height
of a building or structure. Additions to existing buildings shall comply with the
requirements for new construction regardless as to whether the addition is a substantial
improvement or not. Where a firewall or load-bearing wall is provided between the
addition and the existing building, the addition(s) shall be considered a separate building
and must comply with the standards for new construction.
APPEAL is a request for a review of the building official’s interpretation of any provision
of the chapter to the Construction Board of Adjustment and AppealBoard of Zoning
Appeals.
APPURTENANT STRUCTURE is a structure which is on the same parcel of property as the
principal structure, the use of which is incidental to the use of the principal structure in
light of its stated objectives.
FOR REFERENCE ONLY, NOT UP FOR PLANNING COMMISSION VOTE
AREA OF SPECIAL FLOOD HAZARD is the land in the floodplain within a community,
subject to a 1% or greater chance of flooding in any given year. For purposes of these
regulations, the term “special flood hazard area (SFHA)” is synonymous in meaning with
the phrase “area of special flood hazard”.
BASE FLOOD or 100 YEAR FLOOD means the flood having a 1% chance of being equaled
or exceeded in any given year.
BASEMENT means area of a building having its floor subgrade (below ground level) on all
sides.
BREAKAWAY WALL means a wall that is not part of the structural support of a building
that is intended through its design and construction to collapse under specific lateral
loading forces without causing damage to the elevated portion of the building or the
supporting foundation system.
BUILDING - See STRUCTURE.
BUILDING OFFICIAL The individual charged with administration and enforcement of the
building codes and floodplain regulations for the Town of James Island.
BUILDING PERMIT includes mechanical, electrical, plumbing, and any other permits
issued by the Town Building Official.
COASTAL “AE” ZONE are areas subject to inundation by at least 1% annual chance flood
event as determined by detailed methods, and where wave action is expected with wave
heights between 1.5 and 3.0 feet. COASTAL AE ZONES are landward of the VE Zone up to
the Limit of Moderate Wave Action (LIMWA) line. This area may also be referred to as a
Coastal “A” Zone.
COASTAL HIGH HAZARD AREA means an area of special flood hazard extending from
offshore to the inland limit of a primary frontal dune along an open coast and any other
area subject to flooding and high velocity waters caused by, but not limited to, hurricane
wave wash. This includes zones V and VE.
CONDITIONAL LETTER OF MAP REVISION (CLOMR) is a formal review and comment as to
whether a proposed flood protection project or other project complies with the minimum
National Flood Insurance Program (NFIP) requirements for such projects with respect to
delineation of special flood hazard areas. A CLOMR does not revise the effective Flood
Insurance Rate Map (FIRM) or Flood Insurance Study (FIS). Upon submission and approval
of certified as-built documentation, a Letter of Map Revision (LOMP) may be issued by
FEMA to revise the effective FIRM. Building permits and/or flood development permits
cannot be issued based on a CLOMR, because a CLOMR does not change the NFIP map.
CRITICAL FACILITY means a structure or facility that:
(1) Produces, uses, or stores highly volatile, flammable, explosive, toxic and/or water-
reactive materials; or
FOR REFERENCE ONLY, NOT UP FOR PLANNING COMMISSION VOTE
(2) Is a hospital, nursing home, or housing likely to contain occupants who may not be
sufficiently mobile to avoid death or injury during a flood; or
(3) Is a police station, fire station, vehicle and equipment storage facility or emergency
operations center that is needed for flood response activities before, during, or after a
flood; or
(4) Is a public or private utility facility that is vital to maintaining or restoring normal
services to flooded areas before, during or after a flood.
CRITICAL FEATURE means an integral and readily identifiable part of a flood protection
system, without which the flood protection provided by the entire system would be
compromised.
CURVILINEAR LINE means the border on either a FHBM or FIRM that delineates the
special flood, mudslide (i.e., mudflow), and/or flood-related erosion hazard areas and
consists of a curved or contour line that follows the topography.
DATUM Is the National Geodetic Vertical Datum of 1929 (NGVD 29) on FIRMs dated
November 17, 2004 or before and North American Vertical Datum of 1988 (NAVD 88) on
FIRMs dated after November 17, 2004.
DESIGN FLOOD ELEVATION (DFE) is Base Flood Elevation (BFE) plus freeboard.
DEVELOPED AREA means an area of a community that is:
(1) A primarily urbanized, built-up area that is a minimum of 20 contiguous acres, has
basic urban infrastructure including roads, utilities, communications, and public facilities,
to sustain industrial, residential, and commercial activities, and
(a) Within which 75% or more of the parcels, tracts, or lots contain commercial,
industrial, or residential structures or uses; or
(b) A single parcel, tract, or lot in which 75% of the area contains existing commercial
or industrial structures or uses; or
(c) A subdivision developed at a density of at least two residential structures per acre
within which 75% or more of the lots contain existing residential structures at the time the
designation is adopted.
(2) Undeveloped parcel, tract, or lot, the combination of which is less than 20 acres and
is contiguous on at least three sides to areas meeting the criteria of division (1)(a) above at
the time the designation is adopted.
(3) A subdivision that is a minimum of 20 contiguous acres that has obtained all
necessary government approvals, provided that the actual “start of construction” of
structures has occurred on at least 10% of the lots or remaining lots of a subdivision of
10% of the maximum building coverage or remaining building coverage allowed for a
single lot subdivision at the time the designation is adopted and construction of structures
FOR REFERENCE ONLY, NOT UP FOR PLANNING COMMISSION VOTE
is underway. Residential subdivisions must meet the density criteria in division (1)(c)
above of this definition.
DEVELOPMENT means any manmade change to improved or unimproved real estate
including, but not limited to, buildings or other structures, mining, dredging, filling,
grading, paving, excavating, drilling operations, or storage of equipment or materials or
comparable activity of operation; any material change in the use or appearance of any
structure or in the land itself; the division of land into parcels; any change in the intensity
of use of land (such as an increase in the number of dwelling units in a structure); and
change from one use of another use; and any activity that alters a river, stream, lake, pond,
canal, woodland, wetland, endangered species habitat, or other natural resource area.
DEVELOPMENT does include agriculture and forestry operations.
DIRECTOR OF PUBLIC WORKS means the director of the Town of James Island
Department of Public Works.
ELEVATED BUILDING is a non-basement building which has its lowest elevated floor
raised above the ground level by means of fill, solid foundation perimeter walls, pilings,
columns, piers, or shear walls.
EXISTING CONSTRUCTION is, for the purposes of determining rates, any structures for
which the start of construction commenced before January 1, 1975November 15, 1973.
EXISTING CONSTRUCTION may also be referred to as “existing structures” or “Pre-FIRM
Structure”.
EXISTING MANUFACTURED HOME PARK OR SUBDIVISION means a manufactured home
park or subdivision for which the construction of facilities for servicing the lots on which
the manufactured homes are to be affixed (including, at a minimum, the installation of
utilities, the construction of streets, and either final site grading or the pouring of concrete
pads) was completed before November 15,1973.
EXPANSION TO AN EXISTING MANUFACTURED HOME PARK OR SUBDIVISION means
the preparation of additional sites by the construction of facilities for servicing the lots on
which the manufactured homes are to be affixed (including the installation of utilities, the
construction of streets, and either final site grading or the pouring of concrete pads).
FARM STRUCTURE is a structure which is constructed on a farm, other than a residence
or a structure attached to it, for use on the farm including, but not limited to, barns, sheds
and poultry houses, but not including public livestock areas.
FEMA refers to the Federal Emergency Management Agency.
FLOOD or FLOODING means a general and temporary condition of partial or complete
inundation of normally dry land areas from:
(1) The overflow of inland or tidal waters; and/or
(2) The unusual and rapid accumulation or runoff of surface waters from any source.
FOR REFERENCE ONLY, NOT UP FOR PLANNING COMMISSION VOTE
Note: A flood inundates a floodplain. Most floods fall into three major categories:
riverine flooding, coastal flooding, and shallow flooding. Structures could fall in the
floodplain.
FLOOD ELEVATION STUDY refers to an examination, evaluation and determination of
flood hazards and, if appropriate, corresponding water surface elevations, or an
examination, evaluation and determination of mudslide (i.e., mudflow) and/or flood-
related erosion hazards.
FLOOD HAZARD BOUNDARY MAP (FHBM) is an official map of a community, issued by
the Federal Insurance Administrator, where the boundaries of the flood, mudslide (i.e.,
mudflow) and related erosion areas having special hazards have been designated.
FLOOD INSURANCE RATE MAP (FIRM) is an official map of a community, on which the
Federal Insurance Administrator has delineated both the areas of special flood hazard and
the risk premium zones applicable to the community. A FIRM that has been made available
digitally is called a Digital Flood Insurance Rate Map (DFIRM). A FIRM may also refer to a
Flood Insurance Risk Map.
FLOOD INSURANCE STUDY see FLOOD ELEVATION STUDY.
FLOODPLAIN or FLOOD-PRONE AREA means any land area susceptible to being
inundated by water from any source.
FLOODPLAIN MANAGEMENT refers to the operation of an overall program of corrective
and preventive measures for reducing flood damage, including but not limited to,
emergency preparedness plans, flood control works and floodplain management
regulations.
FLOODPLAIN MANAGEMENT REGULATIONS refers to state or local regulations, in any
combination thereof, which provide standards for the purpose of flood damage prevention
and reduction.
FLOODPROOFING means any combination of structural and non-structural additions,
changes, or adjustments to structures which reduce or eliminate flood damage to real
estate or improved real property, water and sanitary facilities, structures and their
contents.
FLOODWAY see REGULATORY FLOODWAY.
FLOODWAY ENCROACHMENT LINES refers to the lines marking the limits of floodways
on federal, state and local flood plain maps.
FREEBOARD is a factor of safety usually expressed in feet above a mandatory base flood
elevation for purposes of floodplain management.
FUNCTIONALLY DEPENDENT USE means a use which cannot perform its intended
purpose unless it is located or carried out in close proximity to water, such as a docking or
port facility necessary for the loading and unloading of cargo or passengers, shipbuilding
FOR REFERENCE ONLY, NOT UP FOR PLANNING COMMISSION VOTE
or ship repair. The term does not include long-term storage or related manufacturing
facilities.
HAZARDOUS VELOCITIES Refers to hydrodynamic pressure must be considered in the
design of any foundation system where velocity waters or the potential for debris flow
exists. If flood velocities are excessive (greater than five feet per second), foundation
systems other than solid foundations walls should be considered so that obstructions to
damaging flood flows are minimized.
HIGHEST ADJACENT GRADE means the highest natural elevation of the ground surface,
prior to construction, next to the proposed walls of a structure.
HISTORIC STRUCTURE means any structure that is:
(1) Listed individually on the National Register of Historic Places (a listing maintained
by the Department of Interior) or preliminarily determined by the Secretary of the Interior
as meeting the requirements or potentially eligible for individual listing on the National
Register;
(2) Certified or preliminarily determined by the Secretary of the Interior as
contributing to the historical significance of a registered historic district or a district
preliminarily determined by the Secretary to qualify as a registered historic district;
(3) Individually listed on a state inventory of historic places in states with historic
preservation programs which have been approved by the Secretary of the Interior; or
(4) Individually listed on a local inventory of historic places that has been certified by
the South Carolina Department of Archives and History.
IMPROVEMENT is any alteration, addition, or structural repair to an existing structure
where “substantial improvement” or “substantial damage” is not a factor.
LAND CHARACTERISTIC is an attribute of land that can be measured or estimated.
LETTER OF MAP AMENDMENT (LOMA) is an official amendment, by letter, to an effective
Nation Flood Insurance Program (NFIP) map. A LOMA establishes a property’s or
structures location in relation to th especial flood hazard area (SFHA). LOMAs are usually
issued because a property or structure has been inadvertently mapped as being in the
floodplain but is actually on natural high ground above the base flood elevation.
LETTER OF MAP CHANGE (LOMC) is an official FEMA determination, by letter, to amend or
revise effective flood insurance rate maps, flood boundary and floodway maps, and flood
insurance studies. LOMCs are issued in the following categories: Letter of Map Revision
(LOMR) and Letter of Map Revision Based On Fill (LOMR-F).
LETTER OF MAP REVISION (LOMR) refers to FEMA’s modification to an effective flood
insurance rate map (FIRM) or a flood boundary and floodway map (FBFM) or both. LOMRs
are general based on the implementation of physical measures that affect the hydrologic or
hydraulic characteristics of a flooding source and thus result in the modification of the
existing regulatory floodway, the effective base flood elevations (BFEs), to the special flood
FOR REFERENCE ONLY, NOT UP FOR PLANNING COMMISSION VOTE
hazards area (SFHA). The LOMR officially revises the Flood I nsurance Rate Map (FIRM) or
the Flood Boundary and Floodway Map (FBFM), and sometimes the flood insurance study
(FIS) report, and when appropriate, includes a description of the modifications. The LOMR
is generally accompanied by an annotated copy of the affected portions of the FIRM, FBFM,
or FIS report.
LETTER OF MAP REVISION BASED ON FILL (LOMR-F) refers to FEMA’s modification of the
special flood hazard area (SFHA) shown on the flood insurance rate map (FIRM) based on
the placement of fill outside the existing regulatory floodway. The LOMR-F does not
changes the FIRM, FBFM, or FIS report.
LIMIT OF MODERATE WAVE ACTION (LIMWA) is the line shown on FIRMs to indicate the
inland limit of the area expected to receive one- half foot or greater breaking waves during
a 1% annual flood event.
LIMITED STORAGE Is an area used for storage and intended to be limited to incidental
items that can withstand exposure to the elements and have low flood damage potential.
Such an area must be of flood resistant or breakaway material, void of utilities except for
essential lighting and cannot be temperature controlled. If the area is located below the
base flood elevation in an A, AE and A1-A30 zone it must meet the requirements of §
151.41(A)(4). If the area is located below the base flood elevation in a V, VE and V1-V30
zone it must meet the requirements of § 151.41(C).
LOW VALUE STRUCTURE see ACCESSORY STRUCTURE.
LOWEST ADJACENT GRADE (LAG) is an elevation of the lowest ground surface that
touches any deck support, exterior walls of a building or proposed building walls.
MANGROVE STAND refers to an assemblage of mangrove trees which is mostly low trees
noted for a copious development of interlacing adventitious roots above the ground and
which contain one or more of the following species: Black mangrove (Avicennia nitida);
Red mangrove (Rhizophora mangle); White mangrove (Longunculariaracemosa); and
buttonwood (Conocarpus erecta).
MANUFACTURED HOME means a structure, transportable in one or more sections, which
is built on a permanent chassis and is designed to meet HUD standards, for use with or
without a permanent foundation when attached to the required utilities. The term
MANUFACTURED HOME does not include a “recreational vehicle”.
MANUFACTURED HOME PARK OR SUBDIVISION means a parcel (or contiguous parcels)
of land divided into two or more manufactured home lots for rent or sale.
MANUFACTURED HOME PERMANENT FOUNDATION is a foundation designed by a
professional engineer registered in South Carolina, with said design subject to the approval
of the Building Official. A bolt-on/bolt-off foundation system is considered as a permanent
foundation for mobile homes placed into a manufactured home park.
MEAN SEA LEVEL is, for the purpose of this chapter, the National Geodetic Vertical Datum
(NGVD) of 1929, North American Vertical Datum (NAVD) of 1988, or other datum, to which
FOR REFERENCE ONLY, NOT UP FOR PLANNING COMMISSION VOTE
the base flood elevations shown on a community’s Flood Insurance Rate Maps (FIRM) are
shown.
MODULAR BUILDING UNIT is a building or set of building components manufactured off-
site and transported to the point of use for installation or erection, with or without other
specified components, as a finished building and not designed for ready removal to another
site, and built in accordance to the Modular Construction Act of the State of South Carolina.
This term is not to be limited to residential dwellings.
NEW CONSTRUCTION is, for flood plain management purposes, structures for which the
start of construction commenced on or after the effective date of the NFIP community’s a
fFloodp Plain mManagement oOrdinance adopted by the NFIP community, November 15,
1973 and includes subsequent improvements to such structures, also known as Post-FIRM.
(Exception: An addition to an existing structure (built prior to November 15, 1973) is not
considered “new construction” unless it is a substantial improvement.)
NEW DEVELOPMENT is any of the following actions undertaken by any person, including,
without limitation, any public or private individual entity: a) division of combination of
lots, tracts, or parcels of other divisions by plat or deed; b) the construction, installation, or
alteration of land, a structure, impervious surface or drainage facility; c) clearing, scraping,
grubbing or otherwise significantly disturbing the soil, vegetation, mud, sand, or rock of a
site, or changing the physical drainage characteristics of the site; or d) adding, removing,
exposing, excavating, leveling, grading, digging, burrowing, dumping, piling, dredging, or
otherwise disturbing the soil, vegetation, mud, sand or rock of a site. The transition from
native landscapes to a developed condition reduces the infiltration, evapotranspiration,
and surface roughness onsite, regardless of the amount of green space and BMPs
implemented into the site design.
NEW MANUFACTURED HOME PARK OR SUBDIVISION refers to a manufactured home
park or subdivision for which the construction of facilities for servicing the lots on which
the manufactured homes are to be affixed (including, at a minimum, the installation of
utilities, the construction of streets, and either final site grading or the pouring of concrete
pads) was completed on or after November 15, 1973, also known as Post-FIRM.
NFIP is the National Flood Insurance Program
PLANNING AND ZONING OFFICIAL refers to the individual charged with administration
and enforcement of planning and zoning for the Town.
POST-FIRM STRUCTURE is a building for which construction or substantial improvement
occurred after November 15, 1973. See NEW CONSTRUCTION.
PRIMARY OCEANFRONT SAND DUNE is a continuous or nearly continuous mound or
ridge of sand with relatively steep seaward and landward slopes immediately landward
and adjacent to the beach and subject to erosion and overtopping from high tides and
waves during major coastal storms. The inland limit of the primary frontal dune occurs at
the point where there is a distinct change from a relatively steep slope to a relatively mild
slope.
FOR REFERENCE ONLY, NOT UP FOR PLANNING COMMISSION VOTE
RECREATIONAL VEHICLE means a vehicle, for flood insurance purposes, which is:
(1) Built on a single chassis;
(2) Four hundred square feet or less when measured at the largest horizontal
projection;
(3) Designed to be self-propelled or permanently towable by a light duty truck; and
(4) Designed primarily not for use as a permanent dwelling but as temporary living
quarters for recreational, camping, travel, or seasonal use.
REDEVELOPMENT is a development on a previously developed site where the impervious
surface on the previously developed site is equal to or greater than 20% of the total site or
where any repair, reconstruction, or improvements, to that site or to any structures located
on that site such that the cumulative costs of repairs, reconstruction, or improvements,
over a five-year period equals or exceeds 49% of the fair market value of the property and
the structures located on that property. The cost of repairs, reconstruction, or
improvements includes remodeling of existing building interiors, resurfacing of paved
areas, and exterior building changes. The cost of repairs excludes ordinary maintenance
activities that do not materially increase or concentrate stormwater runoff, or cause
additional nonpoint source pollution.
REPETITIVE LOSS refers to a building covered by a contract for flood insurance that has
incurred flood related damages on two occasions during a ten-year period ending on the
date of the event for which a second claim is made, in which the cost of repairing flood
damage, on the average, equaled or exceeded 25% of the market value of the building at the
time of each such flood event.
REPETITIVE LOSS AREA is an area with one or more repetitive loss structures and
includes at-risk properties for flooding who may or may not be in a special flood hazard
area (SFHA) as well as those who have made a flood insurance claim previously but do not
qualify as a repetitive loss property.
REPETITIVE LOSS PROPERTY is an insurable building for which two or more claims of
more than $1,000 were paid by the National Flood Insurance Program (NFIP) within any
rolling ten-year period, since 1978. A RL PROPERTY may or may not be currently insured
by the NFIP.
RESILIENCE is the ability of a community to respond, adapt, and thrive under changing
conditions, including, but not limited to, recurrent burdens and sudden disasters.
REGULATORY FLOODWAY is the channel of a river or other watercourse and the adjacent
land areas that must be reserved in order to discharge the base flood without cumulatively
increasing the water surface elevation more than one-half of one foot.
REMEDY A VIOLATION means to bring the structure or other development into
compliance with state or local floodplain management regulations, or, if this is not
reasonably possible as provided in the standards for grant of a variance, to reduce the
impacts of its noncompliance. Ways that impacts may be reduced include protecting the
FOR REFERENCE ONLY, NOT UP FOR PLANNING COMMISSION VOTE
structure or other affected development from flood damages, implementing the
enforcement provisions of the ordinance or otherwise deterring future similar violations,
or reducing federal, state or local financial exposure with regard to the structure or other
development.
RIVERINE is relating to, formed by, or resembling a river (including tributaries), stream,
brook, etc.
SAND DUNE is a naturally occurring accumulations of sand in ridges or mounds landward
of the beach.
SEA LEVEL RISE is an increase in sea level that is primarily related to climate change:
added water from melting ice sheets and glaciers and the expansion of seawater as it
warms. Global sea level has been increasing over the past century, and the rate has
increased in recent decades.
SECTION 1316 OF THE NATIONAL FLOOD INSURANCE ACT OF 1968 is the Act provides
that no new flood insurance shall be provided for any property found by the Federal
Emergency Management Agency to have been declared by a state or local authority to be in
violation of state of local ordinances.
SEVERE REPETITIVE LOSS PROPERTY is a property with at least four flood insurance
claims for buildings and/or contents of more than $5,000 or at least two building-only
payments that cumulatively exceeded the value of the property.
SIXTY-YEAR SETBACK is a distance equal to 60 times the average annual long term
recession rate at a site, measured from the reference feature.
SMALL ACCESSORY STRUCTURES see ACCESSORY STRUCTURE.
SPECIAL FLOOD HAZARD AREA (SFHA) see AREA OF SPECIAL FLOOD HAZARD.
SPECIAL HAZARD AREA is an area having special flood, mudslide (i.e., mudflow), or flood-
related erosion hazards, and shown on a flood hazard boundary map or flood insurance
rate map.
START OF CONSTRUCTION other than new construction or substantial improvements
under the Coastal Barrier Resources Act (Pub. L. 97-348), includes substantial
improvement, and means the date the construction permit was issued, provided the actual
start of construction, repair, reconstruction, rehabilitation, addition placement, or other
improvement was within 180 days of the permit date. The actual start means either the
first placement of permanent construction of a structure on a site, such as the pouring of
slab or footings, the installation of piles, the construction of columns, or any work beyond
the stage of excavation; or the placement of a manufactured home on a foundation.
Permanent construction does not include land preparation, such as clearing, grading and
filling; nor does it include the installation of streets and/or walkways; nor does it include
excavation for a basement, footings, piers, or foundations or the erection of temporary
forms; nor does it include the installation on the property of accessory buildings, such as
garages or sheds not occupied as dwelling units or not part of the main structure. For a
FOR REFERENCE ONLY, NOT UP FOR PLANNING COMMISSION VOTE
substantial improvement, the actual start of construction means the first alteration of any
wall, ceiling, floor, or other structural part of a building, whether or not that alteration
affects the external dimensions of the building.
STEM WALLS are a solid perimeter foundation wall on a continuous spread footing
backfilled to the underside of the floor slab. Refer to Flood Elevation Diagram Number 1B.
STRUCTURE means, for flood plain management purposes, a walled and roofed building,
including gas or liquid storage tanks, that is principally above ground, as well as modular
and manufactured homes.
SUBDIVISION is all divisions of a tract or parcel of land into two or more lots, building
sites, or other divisions for the purpose, whether immediate or future, of sale, lease, or
building development, and includes all division of land involving a new street or change in
existing streets, and includes resubdivision which would involve the further division or
relocation of lot lines of any lot or lots within a subdivision previously made and approved
or recorded according to law; or, the alteration of any streets or the establishment of any
new streets within any subdivision previously made and approved or recorded according
to law, and includes combination of lots of record. (Stormwater and Planning/Zoning)
SUBSTANTIAL DAMAGE means damage of any origin sustained by a structure whereby
the cost of restoring the structure to its before-damaged condition would equal or exceed
4950% of the market value of the structure before the damage occurred as determined by
the Building Official. Flood plain management requirements for new construction apply to
substantial damage.
SUBSTANTIAL IMPROVEMENT means any reconstruction, rehabilitation, addition or
other improvement of a structure, taking place during any five consecutive years in the life
of a building, the cumulative cost of which equals or exceeds 4950% of the market value of
the existing structure at the date of “start of construction” of the improvement as
determined by the Building Official. This term includes structures which have incurred
“substantial damage,” regardless of the actual repair work performed. The term does not,
however, include either:
(1) Any project for improvement of a structure to correct existing violations of state or
local health, sanitary, or safety code specifications which have been identified by the local
code enforcement official and which are the minimum necessary to assure safe living
conditions; or
(2) Any alteration of a historic structure provided that the alteration will not preclude
the structure’s continued designation as a historic structure.
THIRTY-YEAR SETBACK is a distance equal to 30 times the average annual long term
recession rate at a site, measured from the reference feature.
UNNUMBERED A ZONE is a zone without base flood elevations determined. These are still
considered special flood hazard areas.
FOR REFERENCE ONLY, NOT UP FOR PLANNING COMMISSION VOTE
VARIANCE is a grant of relief from the requirements of this chapter which permits
construction in a manner otherwise prohibited by this chapter where specific enforcement
would result in exceptional hardship.
VE ZONE are high risk areas subject to inundation by at least a 1% annual chance flood
event as determined by detailed methods, and where wave action is expected with wave
heights of more than three feet. BFEs or base flood depths are shown within these zones.
VIOLATION is the failure of a structure or other development to be fully compliant with
the Town’s floodplain management regulations. A structure or other development without
the elevation certificate, other certifications, or other evidence of compliance required in
this chapter is presumed to be in violation until such time as that documentation is
provided.
WATER SURFACE ELEVATION is the height of floods of various magnitudes and
frequencies in the floodplains of coastal or riverine areas.
WATERSHEDS are areas of land that drain to a single point, bounded by higher elevations
at the edges. Within a watershed, water travels over land until it reaches a body of water,
and as the water passes farther downstream, draining a larger area, eventually everything
leads to the ocean. In coastal areas, wetlands border the land, and many of the local
streams and creeks enter wetlands border the land, and many of the local streams and
creeks enter wetlands before discharging to the ocean. Wetlands perform a crucial function
in the watershed, intercepting pollutants carried downstream and removing them from the
water in a natural treatment process. Additionally, wetlands slow the water down, acting as
a buffer for hurricanes and reducing severity of flooding.
X ZONE (SHADED) is a moderate risk areas within the 0.2% annual chance floodplain,
areas of 1% annual chance flooding where the average depths are less than one foot. No
BFEs or base flood depths are shown within these zones.
X ZONE (UNSHADED) are the minimal risk areas outside the 1% and 0.2% annual chance
floodplains. No BFEs or base flood depths are shown within these zones.
(Ord. 2016-14, passed 1-19-2017; Ord. 2020-11, passed 12-17-2020)
§ 151.06 LANDS TO WHICH THIS CHAPTER APPLIES.
This chapter shall apply to all areas of special flood hazard within the jurisdiction of the
Town of James Island.
(Ord. 2016-14, passed 1-19-2017)
§ 151.07 BASIS FOR ESTABLISHING THE AREAS OF SPECIAL FLOOD HAZARD.
Charleston County The Town of James Island declares that the Charleston County Flood
Insurance Study, including the FIRMs, dated January 29, 2021, copies of which are on file in
FOR REFERENCE ONLY, NOT UP FOR PLANNING COMMISSION VOTE
the Office of Building Inspection Servicesat Town Hall and online at charlestoncounty.org
and msc.fema.gov, is hereby adopted and declared to be as fully a part of this chapter as if
set forth herein. Letters of Map Change (LOMC) to these adopted maps authorized by the
NFIP shall become effective immediately upon the date established by the NFIP. Permits of
any kind from the Town of James Island will only be issued based on the current effective
data set by the most recent applicable FIRM or LOMC authorized by the National Flood
Insurance Program/ FEMA.
(A) Lands to which this chapter applies. This chapter shall apply to all areas of special
flood hazard within the jurisdiction of the Town of James Island.
(Ord. 2016-14, passed 1-19-2017; Ord. 2018-12, passed 10-18-2018; Ord. 2020-11, passed
12-17-2020)
§ 151.08 WARNING AND DISCLAIMER OF LIABILITY.
The degree of flood protection required by this chapter is considered reasonable for
regulatory purposes and is based on scientific and engineering consideration. Larger floods
can and will occur on rare occasions. Flood heights may be increased by man-made or
natural causes. This chapter does not imply that land outside the areas of special flood
hazard or uses permitted within such areas will be free from flooding or flood damages.
This chapter shall not create liability on the part of the Town or by any officer or employee
thereof for any flood damages that result from reliance on this chapter or any
administrative decision lawfully made thereunder.
(Ord. 2016-14, passed 1-19-2017)
§ 151.09 PROVISIONS CUMULATIVE.
The provisions of this chapter are to be cumulative of all other ordinances or parts of
ordinances governing or regulating the same subject matter as that covered herein,
provided, however, that all prior ordinances or parts of ordinances inconsistent with or in
conflict with any of the provisions of this chapter, including, but not limited to, Ordinance
No. 1526 and 1349, are hereby expressly repealed to the extent of any such inconsistency
or conflict. The enactment of this chapter shall not serve to terminate or be cause for the
termination of the prosecution of any civil or criminal actions under the prior ordinances
which were pending at the time of the enactment hereof.
(Ord. 2016-14, passed 1-19-2017; Ord. 2020-11, passed 12-17-2020)
§ 151.10 SEVERABILITY.
If any provision of this chapter or its application to any circumstance is held by a court of
competent jurisdiction to be invalid for any reason, then this holding does not affect other
FOR REFERENCE ONLY, NOT UP FOR PLANNING COMMISSION VOTE
provisions or applications of this chapter which can be given effect without the invalid
provision or application, and, to this end, the provisions of this chapter are severable.
(Ord. 2016-14, passed 1-19-2017; Ord. 2020-11, passed 12-17-2020)
§ 151.11 ABROGATION AND GREATER RESTRICTIONS.
This chapter shall not in any way impair/remove the necessity of compliance with any
other applicable laws, ordinances, regulations, etc. Where this chapter imposes a greater
restriction, the provisions of this chapter shall control.
(Ord. 2016-14, passed 1-19-2017)
§ 151.12 EFFECTIVE DATE; APPLICATION.
This chapter shall be effective immediately for all new permits issued on or after the date
of ratification.
(Ord. 2016-14, passed 1-19-2017; Ord. 2020-11, passed 12-17-2020)
ADMINISTRATION
§ 151.25 DESIGNATION OF BUILDING OFFICIAL.
As designated by the Town Administrator, tThe Town Building Official (“Building
Official”), and/or his designee, is hereby appointed to administer and implement the
provisions of this chapter.
(Ord. 2016-14, passed 1-19-2017)
§ 151.26 DUTIES AND RESPONSIBILITIES OF THE BUILDING OFFICIAL.
Duties of the Building Official shall include, but not be limited to:
(A) Review all applications for construction permits to assure that the requirements of
this chapter have been satisfied, the requirements of 44 CFR, and are adequate to
determine whether proposed building sites will be reasonably safe from flooding.
(B) Review application for a construction permit on forms furnished by the Building
Official, prior to authorizing the commencement of any construction activities. The
following information, as a minimum, is required to be reviewed:
FOR REFERENCE ONLY, NOT UP FOR PLANNING COMMISSION VOTE
(1) Two A digital set and one hard copy sets of building plans drawn to scale and
showing, at a minimum, elevations for each exterior wall; floor plan(s); foundation and wall
sections and details; stair details; and electrical, plumbing and mechanical riser diagrams.
The plans shall give a full description of proposed construction including a site plan
identifying area(s) having special flood related hazards as applicable.
(2) Plans shall indicate the BFE and the DFE elevation of the proposed building,
verification that materials proposed below the design flood elevation (DFE) are flood
resistant per FEMA Technical Bulletin 2; if applicable, include flood proofing certification
(non-residential), hydrostatic venting information, breakaway wall details and
certifications from a registered architect/engineer.
(C) Maintain permanent copy of building permits issued and copies of all required
certifications for the life of the structure.
(D) Where interpretation is needed as to the exact location and elevation of all areas of
special flood hazard (for example, where there appears to be a conflict between a mapped
boundary and actual field conditions), the Building Official shall make the necessary
interpretation. The person contesting the location of the boundary shall be given a
reasonable opportunity to appeal the interpretation as provided in this chapter.
(E) Maintain a copy of letter of map changes (LOMC) issued by FEMA in the office of the
Building Official.
(F) Maintain on file, for public access, flood maps issued by the Federal Emergency
Management Agency (FEMA).
(G) Review violations that occur during the course of construction. Failure of the
contractor to make required changes shall be cause for issuance of a stop-work order for
the project.
(H) When base flood elevation or floodway data have not been provided by the
applicants, the Building Official shall obtain, review, and reasonably utilize any base flood
elevation and floodway data available from a federal, state or other source.
(I) Advise owners, no new flood insurance coverage may be provided for any new
construction of, or substantial improvement to, a structure located within the coastal
barrier resources system as defined in Section 4 of the Coastal Barrier Resources Act.
(J) Determine the elevation requirement for construction in flood zones.
(K) Review proposed development to assure that all necessary permits have been
received from those governmental agencies from which approval is required by federal or
state law, including section 404 of the Federal Water Pollution Control Act Amendments of
1972, 33 U.S.C. 1334 and that no adverse impact occurs during the development process as
authorized by the 44 CFR 59 and 60.
(L) Notify adjacent communities and the S.C. Natural Resources Department prior to any
alteration or relocation of a watercourse and submit evidence of such notification to the
Federal Emergency Management Agency.
FOR REFERENCE ONLY, NOT UP FOR PLANNING COMMISSION VOTE
(M) Ensure that maintenance and inspections are provided within the altered or
relocated portion of watercourses so that the flood-carrying capacity is not diminished, and
maintaining records of the same until completion of the project.
(N) Notify all repetitive loss area structures of their risk of flooding and the services
available to them.
(Ord. 2016-14, passed 1-19-2017; Ord. 2020-11, passed 12-17-2020)
§ 151.27 DUTIES AND RESPONSIBILITIES OF THE PLANNING AND ZONING OFFICIAL.
Duties and responsibilities of the Planning and Zoning Official shall include, but not be
limited to: require a zoning permit to be issued in conformance with the provisions of the
Town of James Island Zoning and Land Development Regulations, as amended, and/or the
Town of James Island Comprehensive Plan prior to the commencement of any development
or construction activities. The permit shall give a full description of proposed construction.
(Ord. 2016-14, passed 1-19-2017)
§ 151.28 DUTIES AND RESPONSIBILITIES OF THE PUBLIC WORKS OFFICIAL.
Duties and responsibilities of the Public Works Official shall include, but not be limited to,
requiring stormwater permit approval in conformance with the provisions of the Town of
James Island Public Works Stormwater Utility Fee Ordinance, the Town of James Island
Stormwater Management Program, and the Town of James Island Stormwater Program
Standards and Procedures Manual prior to the commencement of any land disturbance or
development activities and requiring encroachment permit approval in conformance with
the SCDOT Roadside Access and Management ManualEncroachment Permit Manual prior
to impacting public right-of-way or easement. The stormwater approval should provide a
full description of the proposed construction.
(A) To coordinate, implement, and manage the Town of James Island’s drainage systems.
(B) To deny a facility connection to Town of James Island stormwater systems or
facilities or discharge to waters of the State if town requirements are not met.
(C) To require the submittal of an application for all applicable construction activities
that cause any land disturbance or alter the storm drainage characteristics of the land. The
application shall include the information required to control stormwater pollutants and
other components in accordance with the current versions of the Charleston County
Stormwater Permitting Standards and Procedures Manual and the Town of James Island
Supplemental Stormwater Design Standards.Stormwater Program Standards and
Procedures Manual.
FOR REFERENCE ONLY, NOT UP FOR PLANNING COMMISSION VOTE
(D) To require the development and enforcement of a stormwater pollution prevention
plan (SWPPP) for all new and re-development projects, as required by the Charleston
County Municipal Separate Storm Sewer System (MS4) Program.
(E) To approve construction activities and to require as a condition of such approval
structural or non-structural controls, practices, devices, operating procedures or other
mechanisms to protect public and private property from flooding, erosion, pollutants, and
attain total maximum daily loads (TMDLs) pollutant reductions and water quality
standards.
(F) To require the submittal of an application for all applicable activities that impact a
public right-of-way or easement.
(G) To require the removal of an encroachment, if necessary, at the expense of the
permittee.
(Ord. 2016-14, passed 1-19-2017)
PROVISIONS FOR FLOOD HAZARD REDUCTION
§ 151.40 GENERAL STANDARDS.
(A) All new construction and substantial improvements within the areas of special flood
hazard shall comply with the following:
(1) Be designed (or modified) and adequately anchored to prevent flotation, collapse,
or lateral movement of the structure resulting from hydrodynamic and hydrostatic loads,
including the effects of buoyancy and debris impact.
(2) Be constructed to meet or exceed the required design flood elevation (DFE), which
is the base flood elevation plus a two-foot freeboard.
(3) When proposed new construction and substantial improvements are partially
located in an area of special flood hazard, the entire structure shall meet the standards for
new construction.
(4) When proposed new construction and substantial improvements are located in
multiple flood hazard risk zones or in a flood hazard risk zone with multiple base flood
elevations, the entire structure shall meet the standards for the most hazardous flood
hazard risk zone and the highest base flood elevation.
(5) Be constructed with Class 4 or 5 materials resistant to flood damage as per FEMA
Technical Bulletin 2, entitled “Flood-Resistant Materials Requirements for Buildings
Located in Special Flood Hazard Areas”, incorporated herein by reference, in all areas
below the design flood elevation,
FOR REFERENCE ONLY, NOT UP FOR PLANNING COMMISSION VOTE
(6) Be constructed by methods and practices that minimize potential for flood
damages.
(7) A temporary construction trailer may only be permitted to be on site for fewer than
180 consecutive calendar days at a time, and must be fully ready for highway use, and shall
be attached to the site only by quick disconnect type utilities and security devices.
(8) Electrical, ventilation, plumbing, heating and air conditioning equipment (including
ductwork), and other service facilities shall be designed and/or located so as to prevent
water from entering or accumulating within the components during conditions of the base
flood plus two feet (freeboard).
(9) Be constructed with methods and practices outlined in ASCE 24 or an at least
equally stringent standard.
(B) Elevation certificate requirements when a structure is constructed or substantially
improved in the area of special flood hazard:
(1) A certified under construction elevation certificate is required, after the lowest
floor is completed and before any further inspections are accepted and vertical
construction commences.
(2) Floodproofing certificate for non-residential construction including floodproofing
level is required immediately after the floodproofing is completed. When floodproofing is
utilized for non-residential structures, said certification shall be prepared by or under the
direct supervision of a professional engineer or architect and certified by same.
(3) A certified finished construction elevation certificate shall be provided after
completion of construction including final grading of the site.
(4) Elevation certificates shall be prepared by or under the direct supervision of a
registered land surveyor or professional engineer and certified by same.
(5) Any work undertaken prior to approval of these certifications shall be at the permit
holder’s risk. The Building Official shall review the above referenced certification data
submitted. Deficiencies detected by such review shall be corrected by the permit holder
immediately and prior to further work being allowed to proceed.
(6) Failure to submit certification or failure to make the corrections required hereby
shall be cause to issue a stop work order for the project and/or the certificate of occupancy
may be withheld.
(C) New development in the area of special flood hazard shall minimize disruption to
shorelines, stream channels, stream banks, and the regulatory floodway.
(D) (1) Water supply systems: All new and replacement water supply systems shall be
designed to minimize or eliminate infiltration of floodwaters into the system.
(2) Sanitary sewage systems: New and replacement sanitary sewage systems shall be
designed to minimize or eliminate infiltration of floodwaters into the systems and
FOR REFERENCE ONLY, NOT UP FOR PLANNING COMMISSION VOTE
discharges from the systems into floodwaters. On-site waste disposal systems shall be
located and constructed to avoid impairment to them or contamination from them during
flooding.
(E) Existing buildings and structures (Pre-FIRM Structures):
(1) Where substantial improvement or substantial damage is not a factor, replacement
of electrical, heating, plumbing, heating and air conditioning equipment to existing
structures shall be elevated to at least the existing lowest floor level or to the design flood
elevation; and replacement ductwork installed below DFE shall be designed so as to
prevent water from entering or accumulating within during conditions of flooding.
(2) Improvements to a structure where substantial improvement or substantial
damage is not a factor shall be designed and constructed so as to meet the requirements of
this chapter, with an exception that the minimum elevation of the lowest floor of an
improvement may match the existing legally non-conforming structure existing lowest
floor.
(F) Modular construction shall be consistent with the South Carolina Modular Building
Construction Act (S.C. Code § 23-43-10 et seq.) as may be amended from time to time,
which is incorporated herein by reference.
(G) Enclosures below the design flood elevation, shall be the minimum necessary to
allow for parking of vehicles, limited storage, or entry to the living area.
(H) An exterior door with a landing shall be installed at the top of the stairs that provide
access to the building.
(I) Accessory residential structure specific standards. New construction or substantial
improvements to residential accessory structures that contain habitable space shall meet
the requirements of new construction as contained in this chapter. Small and/or low value
accessory structures that do not contain habitable space may be exempted from the
elevation requirements in AE Zones only, provided the following conditions are met:
(1) The building is constructed of flood-resistant materials below the design flood
elevation.
(2) Exterior perimeter walls are provided with openings to relieve hydrostatic
pressure and the interior is not partitioned or finished into separate rooms.
(3) Electrical, heating, ventilation, plumbing, air conditioning, and other service
facilities are prohibited, except for essential lighting and power circuits. Flood elevation
certificates may be required to determine the elevation of electric or other utility services
provided to the accessory structure. Service facilities such as electrical and heating
equipment shall be elevated or floodproofed to DFE.
(4) Accessory structures shall be constructed and placed on the building site so as to
offer the minimum resistance to the flow of floodwaters. Accessory structures shall be
firmly anchored to prevent flotation which may result in damage to other structures.
FOR REFERENCE ONLY, NOT UP FOR PLANNING COMMISSION VOTE
(5) The building is used only for parking of vehicles and/or limited storage of
equipment used to service the principal building.
(J) Manufactured home additional specification standards.
(1) Permits shall be obtained for placement of manufactured homes or temporary
construction trailers.
(2) All manufactured homes permitted to be placed shall be installed using methods
and practices which minimize flood damage, which include but are not limited to elevating
the lowest floor of the manufactured home on a permanent foundation, as defined herein as
a MANUFACTURED HOME PERMANENT FOUNDATION, to or above the design flood
elevation in A or AE zones only.
(a) For the purposes of this requirement, manufactured homes must be elevated and
anchored to resist flotation, collapse, or lateral movement.
(b) Methods of anchoring may include, but are not limited to, use of over-the-top or
frame ties to ground anchors.
(c) This requirement is in addition to applicable state and local anchoring
requirements for resisting wind forces.
(d) Designs for manufactured home permanent foundations are subject to approval of
the Building Official.
(K) Recreational vehicles additional specific standards. All recreational vehicles, other
than those parked at another permanent structure temporarily while not in use, place or
sited within special flood hazard areas must:
(1) Be on the site for fewer than 180 consecutive calendar days, and
(2) Be fully registered and ready for highway use. A recreational vehicle is ready for
highway use if it is on its wheels or jacking system, is attached to the site only by quick
disconnect type utilities and security devices, and has no permanently attached additions.
(3) If the vehicle is to remain in an A or AE zone, it must be elevated in accordance with
requirements for manufactured homes as provided in § 151.41.
(Ord. 2016-14, passed 1-19-2017; Ord. 2018-12, passed 10-18-2018; Ord. 2020-11, passed
12-17-2020)
§ 151.41 SPECIFIC STANDARDS IN ADDITION TO GENERAL STANDARDS FOR
UNNUMBERED A ZONES, AE ZONES.
(A) (1) All new construction and substantial improvements of residential structures
shall be elevated so that the top of the lowest floor level (including basement) is elevated to
or above the design flood elevation.
FOR REFERENCE ONLY, NOT UP FOR PLANNING COMMISSION VOTE
(2) All new construction and substantial improvements of non-residential structures
within Zone AE on the community FIRM may be floodproofed below DFE if they are
designed so that below the design flood elevation the structure is watertight with walls
substantially impermeable to the passage of water and with structural components having
the capability of resisting hydrostatic and hydrodynamic loads and effects of buoyancy
including attendant utilities and sanitary facilities.
(3) Where a non-residential structure is intended to be made watertight below the
base flood level:
(a) A registered professional engineer or architect licensed in the state shall develop
and/or review structural design, specifications, and plans for the construction, and shall
certify that the design and methods of construction are in accordance with accepted
standards of practice for meeting the applicable provisions of this chapter, including but
not limited to Floodproofing Non-Residential Buildings (FEMA P-936) as published by the
Federal Emergency Management Agency incorporated herein by reference; and
(b) A record of such certificates which includes the specific elevation (in relation to
mean sea level) to which such structures are flood proofed shall be maintained with the
Building Official.
(4) Enclosed areas below the design flood elevation, including foundation crawl space
areas, shall be designed to automatically equalize hydrostatic and hydrodynamic flood
forces on exterior walls by allowing for the entry and exit of floodwaters. Designs for
meeting this requirement must either be certified by a registered professional engineer or
architect licensed in the state or meet or exceed the following minimum criteria:
(a) A minimum of two openings having a total net area of not less than one square
inch for every square foot of enclosed area subject to flooding shall be provided.
(b) The bottom of all openings shall be no higher than one foot above grade.
(c) Only the portions of openings that are below the base flood elevation (BFE) can be
counted towards the required net open area.
(d) Openings may be equipped with screens, louvers, valves, or other coverings or
devices provided that they permit the automatic entry and exit of flood waters.
(e) The area of the opening is the net clear opening calculated as the open area
(excluding area of screening or other coverings that prohibit the free flow of water through
the opening).
(f) Fill placed around foundation walls must be grated so that the grade inside the
enclosed area is equal to or higher than the adjacent grade outside the building on at least
one side of the building.
(5) In special flood hazard areas without base flood elevation data, new construction or
substantial improvements of structures shall be elevated to at least two feet above the
anticipated flood elevation during a base flood, as determined through an engineering
FOR REFERENCE ONLY, NOT UP FOR PLANNING COMMISSION VOTE
analysis meeting the Federal Emergency Management Agency guidelines for flood
insurance studies with the floodway to be established with no more than one-half foot rise.
(B) Specific standards in addition to general standards for VE and Coastal A zones. VE
zones and Coastal A zones are areas designated as coastal high hazard areas. These areas
have special flood hazards associated with wave wash, and therefore, the following
provisions shall apply:
(1) All new construction and buildings that are substantially damaged or improved
within VE and Coastal A zones are to be located landward of the reach of mean high tide.
(2) Provide that all new construction and substantial improvements in zone VE and
Coastal A Zone, on the Charleston County FIRM, are elevated on pilings or columns so that:
(a) The bottom of the lowest horizontal structural member of the lowest floor
(excluding the pilings or columns) is elevated to or above the design flood elevation; and
(b) The pile or column foundation and structure attached thereto is anchored to
resist flotation, collapse and lateral movement due to the effects of wind and water loads
acting simultaneously on all building components. Water loading values used shall be those
associated with the base flood. Wind loading values used shall be those required by the
International Building Code or International Residential Code as adopted and periodically
amended by the state.
(c) A registered professional engineer or architect licensed in the state shall develop
and/or review the structural design, specifications and plans for construction, and shall
certify that the design and methods of construction are in accordance with accepted
standards of practice for meeting the applicable provisions.
(3) New construction and substantial improvements shall have the space below the
lowest floor either free of obstruction or constructed with non-supporting breakaway
walls, open wood latticework, or insect screening intended to collapse under wind and
water loads without causing collapse, displacement, or other structural damage to the
elevated portion of the building or supporting foundation system. A breakaway wall shall
be permitted only if a registered professional engineer or architect licensed in the state
certifies that the designs proposed meet the following conditions:
(a) Breakaway wall collapse shall result from a water load less than that which would
occur during the base flood; and
(b) The elevated portion of the building and supporting foundations system shall not
be subject to collapse, displacement, or other structural damage due to the effects of wind
and water loads acting simultaneously on all building components (structural and non-
structural). Water loading values used shall be those associated with the base flood. Wind
loading values used shall be those required by applicable state or local building standards.
(c) Electrical, mechanical and plumbing system components are not to be mounted on
or penetrate through walls that are designed to break away under flood loads.
FOR REFERENCE ONLY, NOT UP FOR PLANNING COMMISSION VOTE
(4) There shall be no fill used as structural support. Non-compacted fill may be used
around the perimeter of a building for landscaping/aesthetic purposes provided the fill will
wash out from storm surge, thereby rendering the building free of obstruction prior to
generating excessive loading forces, ramping effects, or wave deflection. The Building
Official shall approve design plans for landscaping/aesthetic fill only after the applicant has
provided an analysis by an engineer, architect, and/or soil scientist licensed in the state
which demonstrates that the following factors have been fully considered:
(a) Particle composition of fill material does not have a tendency for excessive natural
compaction;
(b) Volume and distribution of fill will not cause wave deflection to adjacent
properties; and
(c) Slope of fill will not cause wave run-up or ramping.
(5) Man-made alteration of sand dunes and mangrove stands within zone VE and
Coastal A Zones which would increase potential flood damage shall be prohibited.
(6) Pre-construction and as-built design and breakaway wall certifications, where
applicable, shall be provided by registered professional engineers and/or architects
licensed in the state for new and substantially improved structures in VE and Coastal A
flood zones on the Charleston County FIRM. These certificates shall also be provided for all
lateral additions to structures in the VE and Coastal A flood zones.
(7) Enclosed areas below the lowest floor shall be the minimum necessary to allow for
parking of vehicles, limited storage, and access to the primary occupancy.
(8) Walls intended to break away under flood loads as specified shall have flood
openings that meet the criteria in the general standards section for enclosed space below
design flood elevation.
(9) Appurtenant features, defined as swimming pools, decks, gazebos, fences, and other
features as determined by the Building Official as potentially causing an obstruction in the
coastal high hazard area, must comply with the Federal Emergency Management Agency
(FEMA) Technical Bulletin 5, Free of Obstruction Requirements, or any revisions thereto,
incorporated herein by reference.
(10) Any and all other obstructions located in the VE Zone shall meet all applicable
requirements of this chapter.
(C) Manufactured home and recreational vehicles additional specification standards in
VE and Coastal A Zones.
(1) New or replacement manufactured homes (e.g., those designed to meet HUD
standards) shall not be placed within property located in VE and Coastal A Zones.
(2) Existing manufactured homes in VE and Coastal A Zones may be permitted to
remain as long as the structure complies with minimum health and safety standards and is
anchored to resist flotation, collapse, lateral movement or debris impacts.
FOR REFERENCE ONLY, NOT UP FOR PLANNING COMMISSION VOTE
(3) The placement of a permanent recreational vehicle is prohibited in VE and Coastal
A Zones.
(D) In Coastal A Zones, stem wall foundations supporting a floor system above and
backfilled with soil or gravel to the underside of the floor system shall be permitted
provided that the foundations are designed to account for wave action, debris impact,
erosion and local scour. Where soils are susceptible to erosion and local scour, stem wall
foundations shall have deep footings to account for the loss of soil. Stem walls are to be
limited to a height of two feet above existing grade.
(Ord. 2016-14, passed 1-19-2017; Ord. 2020-11, passed 12-17-2020)
§ 151.42 STANDARDS FOR REGULATORY FLOODWAYS.
Areas of special flood hazard established as regulatory floodways in the Charleston
County Flood Insurance Rate Map (FIRM) and/or the Charleston County Flood Insurance
Study, are the Charleston County designated floodways. Since the floodway is an extremely
hazardous area due to the velocity of flood waters which carry debris, potential projectiles
and has erosion potential, the following provisions shall apply:
(A) Prohibition of encroachments, including fill, new construction, substantial
improvements and other development within the adopted regulatory floodway unless it
has been demonstrated through hydrologic and hydraulic analyses performed in
accordance with standard engineering practice in accordance with the Charleston County
Flood Insurance Study or as otherwise deemed appropriate by FEMA or the Building
Official, certified by a state licensed engineer, that the proposed encroachment would not
result in any increase in flood levels within the community during the occurrence of the
base flood discharges.
(B) (1) Encroachments may be permitted within the adopted regulatory floodway that
would result in an increase in base flood elevations, provided that the town first applies for
a conditional FIRM and floodway revision, fulfills the requirements for such revisions as
established under the provisions of § 65.12 of 44 CFR and receives the approval of the
federal insurance administrator.’
(2) (a) Standards for streams with established base flood elevations but without
floodways along rivers and streams where base flood elevation data is provided but no
floodway is identified for a Special Flood Area on the FIRM or in the FIS. The following
provisions apply within such areas:
(b) No encroachments, including fill material, new construction, or substantial
improvement shall be permitted unless certification with supporting technical data by a
registered professional engineer is provided demonstrating that the cumulative effect of
the proposed development, when combined with all other existing and anticipated
development, will not increase the water surface elevation of the base flood at any point.
FOR REFERENCE ONLY, NOT UP FOR PLANNING COMMISSION VOTE
(C) The area chosen for the regulatory floodway must be designed to carry the waters of
the base flood, without increasing the water surface elevation of that flood more than one -
half foot at any point.
(Ord. 2016-14, passed 1-19-2017; Ord. 2020-11, passed 12-17-2020)
§ 151.43 STANDARDS FOR SUBDIVISION PROPOSALS AND OTHER DEVELOPMENT.
Standards for subdivision proposals shall meet or exceed the following minimum criteria:
(A) All subdivision proposals shall be consistent with the need to minimize flood
damage;
(B) All subdivision proposals shall have public utilities and facilities such as sewer, gas,
electrical and water systems located and constructed to minimize flood damage;
(C) All subdivision proposals shall have adequate drainage provided to reduce exposure
to flood hazards, and;
(D) Base flood elevation data shall be provided for all subdivision proposals (including
manufactured home parks and subdivisions).
(E) In all areas of special flood hazard where base flood elevation data is not available,
the applicant shall provide a hydrologic and hydraulic engineering analysis that generates
base flood elevations for all subdivision proposals and other proposed developments.
(Ord. 2016-14, passed 1-19-2017; Ord. 2020-11, passed 12-17-2020)
APPEALS AND VARIANCES
§ 151.55 APPEAL AND VARIANCE PROCEDURE.
(A) General. In order to hear and decide appeals of orders, decisions or determinations
made by the Building Official relative to the application and interpretation of this chapter,
the Board of Zoning Appeals (BZA) shall be the designated board of officials appointed by
the governing body, as established in Section 153.047 of the Zoning and Land Development
Ordinance.The Charleston County Construction Board of Adjustment and Appeals as
established by the County Council shall hear and decide appeals and requests for variance
meeting the following provisions from the requirements of this chapter:
(1) Public notice of all meeting of the Board shall be provided by at least electronic
delivery to the news television stations, the newspaper of general circulation, the radio
communication companies, and several individual town/jurisdictional distribution papers.
(1) Decisions on which a variance or appeal is requested shall be those made by the
Building Official or his designee.
FOR REFERENCE ONLY, NOT UP FOR PLANNING COMMISSION VOTE
(2) Requests for a hearing for a variance or appeal of a decision shall be in writing, and
shall be received in the office of the Building Official within 30 calendar days of notice to
the appellant of the decision.
(3) The appellant shall be the owner of the property affected by the decision or his or
her duly authorized representative.
(B) This Board shall hear and decide appeals when it is alleged there is an error in any
requirement, decision, or determination made by the Building or the Planning and Zoning
Official in the enforcement or administration of this chapter.
(C) Any person aggrieved by the decision of this Board or any taxpayer may appeal such
decision, as provided in § 6-29-8004-9-30 of the S.C. Code of Laws.
(D) Variances may be issued for the repair or rehabilitation of historic structures upon a
determination that the proposed repair or rehabilitation will not preclude the structure’s
continued designation as a historic structure and the variance is the minimum to preserve
the historic character and design of the structure.
(E) Variances may be issued for a new construction and substantial improvements and
for other development necessary for the conduct of a functionally dependent use provided
that requirements of this section are met and the structure or other development is
protected by methods that minimize flood damages during the base flood and create no
additional threats to public safety.
(F) Variances may be issued to wet flood proof an expansion to an existing farm
structure in accordance with Technical Bulletin 7, Wet Flood Proofing Requirements for
Structures Located in Special Flood Hazard Areas in accordance with the National Flood
Insurance Program available from the Federal Emergency Management Agency. The
structure must meet all of the conditions and considerations for variances otherwise
established within this chapter. In addition, the following standards shall apply:
(1) Use of the structure must be limited to agricultural purposes such as pole frame
buildings with open or closed sides used exclusively for the storage of farm machinery and
equipment; steel grain bins and steel frame corn cribs; and general purpose barns for
temporary feeding of livestock;
(2) The expansion to an existing farm structure must be built or rebuilt, in the case of
an existing building which is substantially damaged, with flood resistant materials for
building elements below the base flood elevation;
(3) The expansion to an existing farm structure must be adequately anchored to
prevent flotation, collapse or lateral movement. All of the structure’s components must be
capable of resisting specific flood-related forces including hydrostatic, buoyancy,
hydrodynamic and debris impact forces;
(4) The expansion to an existing farm structure shall meet the requirements for
hydrostatic venting requirements of this chapter;
FOR REFERENCE ONLY, NOT UP FOR PLANNING COMMISSION VOTE
(5) Electrical, mechanical or other utility equipment must be located at or above the
design flood elevation, or must be maintained in a flood proofed enclosure complying with
this chapter which is capable of resisting damage during flood conditions;
(6) The expansion to an existing farm structure must comply with floodway
encroachment provisions of this chapter; and
(7) Major equipment or machinery must be protected from damage by flooding, which
may include safely removing the contents of an expansion to an existing farm structure to a
specified site out of the flood plain upon notification of potential flooding event.
(G) In passing upon such applications, this Board shall consider all staff reports and
technical evaluations, all relevant factors and all standards specified in other sections of
this chapter, and:
(1) The danger that materials may be swept onto other lands to the injury of others;
(2) The danger to life and property due to flooding or erosion damage;
(3) The susceptibility of the proposed facility and its contents to flood damage and the
effect of such damage on the individual owner;
(4) The importance of the services provided by the proposed facility to the community;
(5) The necessity of the facility to a waterfront location, in the case of a functionally
dependent usage;
(6) The availability of alternative locations, not subject to flooding or erosion damage,
for the proposed use;
(7) The conformance of the proposed use to the Town Comprehensive Plan and the
Town of James Island Zoning and Land Development Regulations;
(8) The safety of access to the property in times of flood for ordinary and emergency
vehicles;
(9) The expected heights, velocity, duration, rate of rise and sediment transport of the
flood waters and the effects of wave action, if applicable, expected at the site during a base
flood event; and
(10) The costs of providing governmental services to the site during and after flood
conditions, including maintenance and repair of public utilities and facilities, such as sewer,
gas, electrical and water systems, and streets and bridges.
(H) The Board may attach such reasonable conditions to the granting of variances as it
deems necessary to further the purpose of this chapter.
(I) Variances shall not be issued within any designated floodway if any increase in flood
levels during the base flood discharge would result, nor shall a variance be based on
financial hardship alone; nor solely due to existing or as-built elevation deficiencies that
will cause extreme hardship.
FOR REFERENCE ONLY, NOT UP FOR PLANNING COMMISSION VOTE
(J) Conditions for variances.
(1) Variances shall be issued only on a determination that the variance is the minimum
necessary needed to afford relief considering the flood hazard; and in the instance of an
historical building, a determination that the variance is the minimum necessary so as not to
destroy the historic character and design of the building;
(2) Variances shall be issued only upon:
(a) A showing of good and sufficient cause;
(b) A determination that failure to grant the variance would result in exceptional
hardship; and
(c) A determination that the granting of a variance will not result in increased flood
heights, additional threats to public safety, extraordinary public expense, creation of a
nuisance, fraud on or victimization of the public, or conflict with other existing laws or
ordinances.
(3) Any applicant to whom a variance is granted shall be given written notice
specifying the differences between the base flood elevation and the elevation of which the
building is to be built and a statement that the cost of flood insurance will be
commensurate with the increased risk resulting from the reduced lowest floor elevation.
(4) The Building Official shall maintain the records of all appeal actions and report any
variances granted to the Federal Emergency Management Agency upon request.
(5) Variances may not be issued when the variance will make the structure in violation
of other federal, state or local laws, regulations or ordinances.
(Ord. 2016-14, passed 1-19-2017)
COMPLIANCE FOR PROPOSED REAL ESTATE TRANSACTIONS
§ 151.70 PROVISION FOR INSPECTIONS.
(A) For the purpose of establishing pre-existing conditions which may not be in
compliance with the Town of James Island Flood Damage Prevention and Protection
Ordinance, it is hereby established that the Building Official or designee Building Services
Department is authorized to conduct inspections of existing structures at the request or
with the consent of the owner of the structure or his agent for compliance with the Town of
James Island Flood Damage Prevention and Protection Ordinance when requested for a
proposed real estate transaction or insurance policy issue.
(B) The Building Official may promulgate regulations for the implementation of this
program, consistent with the intent hereof and with the terms of the remainder of Chapter
151 of the Code of Ordinances of the Town of James Island.
FOR REFERENCE ONLY, NOT UP FOR PLANNING COMMISSION VOTE
(C) These inspections are to be conducted at a convenient time for the property owner
or his agent and during the normal operating hours of the Building Services Department.
(D) Reports generated as a result of these inspections are to be considered public
records and are to be maintained in the Office of the Building Official in accordance with
the Town’s records retention schedule.
(Ord. 2016-14, passed 1-19-2017)
NUISANCES
§ 151.85 NUISANCES WITHIN A SPECIAL FLOOD HAZARD AREA.
(A) Certain nuisances defined. Notwithstanding anything to the contrary set forth in the
Code of Ordinances, Town of James Island, the following activities occurring within a
special flood hazard area constitute a danger to the health, safety, and welfare of the
residents of the Town, are hereby defined as public nuisances and are prohibited within
any special flood hazard area.
(1) The manufacture, processing, blending, mixing or refining of the following products
as defined in the International Fire Code as adopted by the Town of James Island:
(a) Explosives;
(b) Blasting agents;
(2) Storage of the products listed in division (A)(1) above, except that the retail sale of
packages products off-the-shelf at properly licensed and otherwise authorized retail sales
outlets, is allowed.
(B) Defense - prior use of property. It shall be a defense to prosecution pursuant to
division (A) above if:
(1) Property located within a special flood hazard zone was being used for a purpose
defined as a nuisance in division (A)(1) above, before August 3, 1971, has been
continuously used for such purpose thereafter, and such use:
(a) Was a permitted use pursuant to the county zoning ordinance as of August
3,1971; or
(ab) Constituted a lawful non-conforming use under the countyTown Zoning and
Land Development Regulations Ordinance’s zoning ordinance on August 3,1971; and
(2) Property which becomes located within a special flood hazard area as the result of
an amendment to the county’s FIRM was being used for a purpose defined as a nuisance in
division (A)(1) above, before the effective date of the amended FIRM, has been
continuously used for such purpose thereafter, and such use:
FOR REFERENCE ONLY, NOT UP FOR PLANNING COMMISSION VOTE
(a) Was a permitted use pursuant to the Town Zoning and Land Development
Regulations Ordinance ’s zoning ordinance as of the effective date of the FIRM; or
(b) Constituted a lawful non-conforming use under the town’s zoning ordinanceTown
Zoning and Land Development Regulations Ordinance on the effective date of the FIRM.
(Ord. 2016-14, passed 1-19-2017)
§ 151.99 PENALTY.
(A) Criminal penalties. Violation of the provisions of this chapter or failure to comply
with any of its requirements, including violation of conditions and safeguards established
in connection with grants of variance or special exceptions, shall constitute a misdemeanor.
Any person who violates this chapter or fails to comply with any of its requirements shall,
upon conviction thereof, be fined not more than $500 or imprisoned for not more than 30
days, or both, and in addition, shall pay all costs and expenses involved in the case. Each
day such violation continues shall be considered a separate offense. Nothing herein
contained shall prevent the town from taking such other lawful actions as are necessary to
prevent or remedy any violation.
(B) Civil remedies. In addition to any other criminal or civil remedies that may be
available to the town, the town may seek and obtain an injunction against the owner or
owner's representative with control over the property in accordance with applicable laws
and procedures.
(Ord. 2016-14, passed 1-19-2017)
FOR REFERERENCE ONLY, NOT UP FOR PLANNING COMMISSION VOTE
CHAPTER 150: TOWN BUILDING REGULATIONS
Section
150.01 General provisions
150.02 Applicability
150.03 Department of Building Inspection Services
150.04 Duties and powers of Building Official
150.05 Permits
150.06 Construction documents
150.07 Temporary structures and uses
150.08 Fees
150.09 Inspections
150.10 Certificate of occupancy
150.11 Service utilities
150.12 Licensing and registration
150.13 Unsafe dwellings and equipment
150.14 Construction Board of Adjustment and Appeals
150.15 Violations
150.99
Penalty
Editor’s note:
The regulations set forth in this chapter are those of Charleston County Ordinance 1839,
adopted by the county on January 20, 2015, which was adopted by the Town’s Ordinance
2016-14 on January 19, 2017, as amended.
§ 150.01 GENERAL PROVISIONS.
(A) Title. These regulations shall be known as the Building Code of the Town of James
Island, hereinafter referred to as “this chapter.”
(B) Scope. The provisions of this chapter shall apply to the construction, alteration,
movement, enlargement, replacement, repair, equipment, use and occupancy, location,
FOR REFERERENCE ONLY, NOT UP FOR PLANNING COMMISSION VOTE
maintenance, removal and demolition of every building or structure or any appurtenances
connected or attached to such buildings or structures.
(C) Appendices. Provisions in the appendices shall not apply unless specifically adopted.
(D) Intent. The purpose of this chapter is to regulate the provisions found in S.C. Code §§
6-9-5 et seq. and S.C. Code of Regulations 8-100 et seq. that establish the minimum
requirements to safeguard the public health, safety and general welfare through structural
strength, means of egress facilities, stability, sanitation, adequate light and ventilation,
energy conservation, and safety to life and property from fire and other hazards attributed
to the built environment and to provide safety to fire fighters and emergency responders
during emergency operations.
(E) Referenced codes. The provisions in divisions (E)(1) through (E)(8) below and
referenced elsewhere in this chapter shall be considered part of the requirements of this
chapter to the prescribed extent of each such reference.
(1) Building.
(a) The provisions of the International Building Code as adopted by the S. C. Building
Codes Council shall apply to the construction of buildings and structures.
(b) Exception: Detached one- and two-family dwellings and multiple single-family
dwellings (townhouses) not more than three stories above grade plane in height with a
separate means of egress and their accessory structures shall comply with the
International Residential Code as adopted by the S.C. Building Code Council.
(2) Electrical. The provisions of the National Electrical Code as adopted by the S.C.
Building Codes Council shall apply to the installation of electrical systems, including
alterations, repairs, replacement, equipment, appliances, fixtures, fittings and
appurtenances thereto.
(3) Gas. The provisions of the International Fuel Gas Code as adopted by the S.C.
Building Codes Council shall apply to the installation of gas piping from the point of
delivery, gas appliances and related accessories as covered in this chapter. These
requirements apply to gas piping systems extending from the point of delivery to the inlet
connections of appliances and the installation and operation of residential and commercial
gas appliances and related accessories.
(4) Mechanical. The provisions of the International Mechanical Code as adopted by the
S.C. Building Codes Council shall apply to the installation, alterations, repairs and
replacement of mechanical systems, including equipment, appliances, fixtures, fittings
and/or appurtenances, including ventilation, heating, cooling, air-conditioning and
refrigeration systems, incinerators and other energy-related systems.
(5) Plumbing. The provisions of the International Plumbing Code as adopted by the S.C.
Building Codes Council shall apply to the installation, alteration, repair and replacement of
plumbing systems, including equipment, appliances, fixtures, fittings and appurtenances,
and where connected to a water or sewage system and all aspects of a medical gas system.
FOR REFERERENCE ONLY, NOT UP FOR PLANNING COMMISSION VOTE
(6) Fire prevention. The provisions of the International Fire Code as adopted by the S.C.
Building Codes Council shall apply to matters affecting or relating to structures, processes
and premises from the hazard of fire and explosion arising from the storage, handling or
use of structures, materials or devices, from conditions hazardous to life, property or public
welfare in the occupancy of structures or premises; and from the construction, extension,
repair, alteration or removal of fire suppression and alarm systems or fire hazards in the
structure or on the premises from occupancy or operation.
(7) Energy. The provisions of the International Energy Conservation Code as adopted
by the State of South Carolina shall apply to all matters governing the design and
construction of buildings for energy efficiency.
(8) Unsafe buildings and equipment. (See § 150.13).
(F) Definitions. References throughout this chapter are defined as follows:
CODE OFFICIAL. Shall mean “Building Official.”
(Ord. 2016-14, passed 1-19-2017)
§ 150.02 APPLICABILITY.
(A) Area of applicability. This chapter shall affect all unincorporated areas of the Town,
unless this chapter is adopted by an incorporated area, excluding any parcels of land
owned by the state or the federal government, and any buildings and installations thereon
unless duly requested or required by law.
(B) General. Where, in any specific case, different sections of this chapter specify
different materials, methods of construction or other requirements, the most restrictive
shall govern. Where there is a conflict between a general requirement and a specific
requirement, the specific requirement shall be applicable.
(C) Other laws. The provisions of this chapter shall not be deemed to nullify any
provisions of local, state, or federal law.
(D) Application of references. References to chapter or section numbers, or to provisions
not specifically identified by number, shall be construed to refer to such chapter, section, or
provision of this chapter.
(E) Referenced codes and standards.
(1) The codes and standards referenced in this chapter shall be considered part of the
requirements of this chapter to the prescribed extent of each such reference. Where
differences occur between provisions of this chapter and referenced codes and standards,
the provisions of this chapter shall apply.
(2) Exception: Where enforcement of a code provision would violate the conditions of
the listing of the equipment or appliance, the conditions of the listing and manufacturer’s
instructions shall apply.
FOR REFERERENCE ONLY, NOT UP FOR PLANNING COMMISSION VOTE
(F) Partial invalidity. In the event that any part or provision of this chapter is held to be
illegal or void, this shall not have the effect of making void or illegal any of the other parts
or provisions.
(G) Existing structures.
(1) The legal occupancy of any structure existing on the date of adoption of this chapter
shall be permitted to continue without change, except as is specifically covered in this
chapter or as is deemed necessary by the Building Official for the general safety and
welfare of the occupants and the public.
(2) Existing installations. Building systems lawfully in existence at the time of the
adoption of this chapter shall be permitted to have their use and maintenance continued if
the use, maintenance or repair is in accordance with the original design and no hazard to
life, health or property is created by such system.
(H) Maintenance. All building systems, materials, and appurtenances, both existing and
new, and all parts thereof, shall be maintained in proper operating condition in accordance
with the original design in a safe and sanitary condition. All devices or safeguards required
by this chapter shall be maintained in compliance with the code edition under which they
were installed.
(1) Maintenance of safeguards. Whenever or wherever any device, equipment, system,
condition, arrangement, level of protection, or any other feature is required for compliance
with the provisions of this chapter or otherwise installed, such device, equipment, system,
condition, arrangement, level of protection, or other feature shall thereafter be
continuously maintained in accordance with the chapter and applicable referenced
standards, in effect on the date permitted or if done without permits at the time of
installation.
(2) Testing and operation. Equipment requiring periodic testing or operation to ensure
maintenance shall be tested or operated as specified in this chapter.
(a) Test and inspection records. Required test and inspection records shall be
available to the Building Official at all times.
(b) Reinspection and testing. Where any work or installation does not pass an initial
test or inspection, the necessary corrections shall be made so as to achieve compliance with
this chapter.
(3) Supervision. Maintenance and testing shall be under the supervision of a
responsible person who shall ensure that such maintenance and testing are conducted at
specified intervals in accordance with this chapter.
(4) Rendering equipment inoperable. Portable or fixed fire-extinguishing systems or
devices and fire-warning systems shall not be rendered inoperative or inaccessible except
as necessary during emergencies, maintenance, repairs, alterations, drills or prescribed
testing.
FOR REFERERENCE ONLY, NOT UP FOR PLANNING COMMISSION VOTE
(5) Owner/occupant responsibility. Correction and abatement of violations of this
chapter shall be the responsibility of the owner. If an occupant creates, or allows to be
created, hazardous conditions in violation of this chapter, the occupant shall be held
responsible for the abatement of such hazardous conditions.
(6) Overcrowding. Overcrowding or admittance of any person beyond the approved
capacity of a building or a portion thereof shall not be allowed. The Building Official, upon
finding any overcrowding conditions or obstructions in aisles, passageways, or other
means of egress, or upon finding any condition which constitutes a life safety hazard, shall
be authorized to cause the event to be stopped until such condition or obstruction is
corrected.
(I) Additions, alterations, or repairs. Additions, alterations, or repairs to any structure or
building systems shall conform to that required for a new structure without requiring the
existing structure to comply with all of the requirements of this chapter, unless otherwise
stated. Additions, alterations, or repairs shall not cause an existing structure to become
unsafe or adversely affect the performance of the building. See division (L) of this section
concerning substantial improvements.
(J) Historic buildings.
(1) The provisions of this chapter relating to the construction, alteration, repair,
enlargement restoration, relocation or moving of buildings or structures shall not be
mandatory for existing buildings or structures identified and/or classified by the federal,
state or town as historic buildings when such buildings or structures are judged by the
Building Official to be safe and in the public interest of health, safety and welfare regarding
any proposed construction, alteration, repair, enlargement, restoration, relocation, change
of occupancy, or moving of buildings.
(2) HISTORIC BUILDINGS are defined as:
(a) Listed or preliminarily determined to be eligible for listing in the National
Register of Historic Places;
(b) Determined by the Secretary of the U.S. Department of Interior as contributing to
the historical significance of a registered historic district, or a district preliminarily
determined to qualify as an historic district;
(c) Designated as historic under a state or local historic preservation program that is
approved by the Department of Interior; or
(d) Individually listed on a local inventory of historical places that has been certified
by the South Carolina Department of Archives and History.
(K) Moved buildings. Buildings and/or structures and their components moved into or
within theTown shall comply with the provisions of this chapter for new installations.
(L) Substantially improved or substantially damaged existing buildings and structures.
The Building Official shall examine or cause to be examined the construction documents for
reconstruction, rehabilitation, addition, or other improvement of existing buildings or
FOR REFERERENCE ONLY, NOT UP FOR PLANNING COMMISSION VOTE
structures, and shall prepare a finding with regard to the value of the proposed work. For
buildings that have sustained damage of any origin and/or improvement to a building or
structure, the value of the proposed work shall include the cost to repair the building or
structure to its pre-damaged condition and/or cost of any improvements. If the Building
Official finds that the value of proposed work equals or exceeds 50% of the fair market
value of the building or structure, the entire building or structure shall be brought into
compliance with all applicable codes.
(M) Change in occupancy (Including Use as Short Term Rental). It shall be unlawful to
make a change in the occupancy of any structure which will subject the structure to any
special provision of this chapter applicable to the new occupancy without approval. The
Building Official shall certify that such structure meets the intent of the provisions of law
governing building construction for the proposed new occupancy and that such change of
occupancy does not result in any hazard to the public health, safety, or welfare.
(N) Requirements not covered by this chapter. Requirements necessary for the strength,
stability, or proper operation of an existing or proposed building or structure and its
components, or for the public safety, health and general welfare, not specifically covered by
this chapter, shall be determined by the Building Official.
(Ord. 2016-14, passed 1-19-2017) Penalty, see § 150.99
§ 150.03 DEPARTMENT OF BUILDING INSPECTION SERVICES.
(A) Creation of enforcement agency. The Department of Building Inspection Services is
hereby created and the official in charge thereof shall be known as the Building Official.
(B) Appointment. The Building Official shall be appointed by the appointing
authorityMayor, or his/her designee, of the Town of James Island.
(C) Deputies. In accordance with the prescribed procedures of this Town and with the
concurrence of the appointing authority, the Town Administrator Building Official shall
have the authority to appointassign a Deputy Building Official, the related technical officers,
inspectors, plan examiners, code enforcement officers, and other employees. Such
employees shall have powers as delegated by the Building Official upon approval of the
Town Administrator.
(Ord. 2016-14, passed 1-19-2017)
§ 150.04 DUTIES AND POWERS OF BUILDING OFFICIAL.
(A) General. The Building Official is hereby authorized and directed to enforce the
provisions of this chapter. The Building Official shall have the authority to render
interpretations of this chapter and to adopt policies and procedures in order to clarify the
application of its provisions. Such interpretations, policies and procedures shall be in
FOR REFERERENCE ONLY, NOT UP FOR PLANNING COMMISSION VOTE
compliance with the intent and purpose of this chapter. Such policies and procedures shall
not have the effect of waiving requirements specifically provided for in this chapter.
(B) Applications and permits. The Building Official shall receive applications, review
construction documents and issue permits for the erection, and alteration, demolition and
moving of buildings and structures, inspect the premises for which such permits have been
issued and enforce compliance with the provisions of this chapter.
(C) Notices and orders. The Building Official shall issue all necessary notices or orders to
ensure compliance with this chapter.
(D) Inspections. The Building Official shall make all of the required inspections, or the
Building Official shall have the authority to accept reports of inspection by approved
agencies or individuals. Reports of such inspections shall be in writing and be certified by a
responsible officer of such approved agency or by the responsible individual.
(E) Identification. The Building Official shall carry proper identification when inspecting
structures or premises in the performance of duties under this chapter.
(F) Right of entry. Where it is necessary to make an inspection to enforce the provisions
of this chapter, or where the Building Official has reasonable cause to believe that there
exists in a structure or upon a premises a condition which is contrary to or in violation of
this chapter which makes the structure or premises unsafe, dangerous or hazardous, the
Building Official is authorized to enter the structure or premises at reasonable times to
inspect or to perform the duties imposed by this chapter, provided that if such structure or
premises be occupied that credentials be presented to the occupant and entry requested. If
such structure or premises is unoccupied, the Building Official shall first make a reasonable
effort to locate the owner or other person having charge or control of the structure or
premises and request entry. If entry is refused, the Building Official shall have recourse to
the remedies provided by law to secure entry.
(G) Department records. The Building Official shall keep official records of applications
received, permits and certificates issued, fees collected, reports of inspections, and notices
and orders issued. Such records shall be retained in the official records for the period
required for retention of public records.
(H) Liability. The Building Official, member of the board designated to review appeals,
Construction Board of Adjustment and Appeals or employee charged with the enforcement
of this chapter, while acting for the Town in good faith and without malice in the discharge
of the duties required by this chapter or other pertinent law or ordinance, shall not thereby
be rendered liable personally and is hereby relieved from personal liability for any damage
accruing to persons or property as a result of any act or by reason of an act or omission in
the discharge of official duties. Any suit instituted against an officer or employee because of
an act performed by that officer or employee in the lawful discharge of duties and under
the provisions of this chapter shall be defended by legal representative of the Town until
the final termination of the proceedings. The Building Official or any subordinate shall not
be liable for cost in any action, suit or proceeding that is instituted in pursuance of the
provisions of this chapter.
FOR REFERERENCE ONLY, NOT UP FOR PLANNING COMMISSION VOTE
(I) Approved materials and equipment.
(1) Materials, equipment, and devices approved by the Building Official shall be
constructed and installed in accordance with such approval.
(2) Used materials and equipment. The use of used materials which meet the
requirements of this chapter for new materials is permitted. Used equipment and devices
shall not be reused unless approved by the Building Official.
(J) Modifications. Wherever there are practical difficulties involved in carrying out the
provisions of this chapter, the Building Official shall have the authority to grant
modifications for individual cases, upon application of the owner or owner’s
representative, provided the Building Official shall first find that special individual reason
makes the strict letter of this chapter impractical and the modification is in compliance
with the intent and purpose of this chapter and that such modification does not lessen
health, accessibility, life and fire safety, or structural requirements. The details of the action
granting modifications shall be recorded and entered in the files of the Department of
Building Services.
(K) Alternative materials, design and methods of construction and equipment. The
provisions of this chapter are not intended to prevent the installation of any material or to
prohibit any design or method of construction not specifically prescribed by this chapter,
provided that any such alternative has been approved. An alternative material, design or
method of construction shall be approved where the Building Official finds that the
proposed design is satisfactory and complies with the intent of the provisions of this
chapter, and that the material, method or work offered is, for the purpose intended, at least
the equivalent of that prescribed in this chapter in quality, strength, effectiveness, fire
resistance, durability, and safety.
(1) Research reports. Supporting data, where necessary to assist in the approval of
materials or assemblies not specifically provided for in this chapter, shall consist of valid
research reports from approved sources.
(2) Tests. Whenever there is insufficient evidence of compliance with the provisions of
this chapter, or evidence that a material or method does not conform to the requirements
of this chapter, or in order to substantiate claims for alternative materials or methods, the
Building Official shall have the authority to require tests as evidence of compliance to be
made at no expense to the Town. Test methods shall be as specified in this chapter or by
other recognized test standards. In the absence of recognized and accepted test methods,
the Building Official shall approve the testing procedures. Tests shall be performed by an
approved agency. Reports of such tests shall be retained by the Building Official for the
period required for retention of public records.
(L) Evacuation. The Building Official and/or the Fire Department Official in charge of an
incident shall be authorized to order the immediate evacuation of any occupied building
deemed unsafe when such building has hazardous conditions that present imminent
danger to building occupants. Persons so notified shall immediately leave the structure or
FOR REFERERENCE ONLY, NOT UP FOR PLANNING COMMISSION VOTE
premises and shall not enter or re-enter until authorized to do so by the Building Official
and/or the Fire Department Official in charge of the incident.
(Ord. 2016-14, passed 1-19-2017) Penalty, see § 150.99
§ 150.05 PERMITS.
(A) Required permits.
(1) Any owner or authorized agent who intends to construct, enlarge, alter, repair,
move, demolish, or change the occupancy of a building or structure, or to erect, install,
enlarge, alter, repair, remove, convert or replace any electrical, gas, mechanical or
plumbing system, the installation of which is regulated by this chapter, or to cause any such
work to be done, shall first make application; to the Building Official and obtain the
required permit.
(2) Additional required permits. The Building Official is authorized to issue permits for
work as set forth in divisions (A)(2)(a) through (A)(2)(c) of this section.
(a) Automatic fire-extinguishing systems. A permit is required for installation of or
modification to an automatic fire-extinguishing system. Maintenance performed in
accordance with this chapter is not considered a modification and does not require a
permit.
(b) Fire alarm and detection systems and related equipment.
1. A permit is required for installation of or modification to fire alarm and detection
systems and related equipment. Maintenance performed in accordance with this chapter is
not considered a modification and does not require a permit.
2. Exception: Residential type smoke detectors installed individually or wired in
series in single-family residences.
(c) Fire pumps and related equipment. A permit is required for installation of or
modification to fire pumps and related fuel tanks, jockey pumps, controllers, and
generators. Maintenance performed in accordance with this chapter is not considered a
modification and does not require a permit.
(d) Hazardous materials. A permit is required to install, repair damage to, abandon,
remove, place temporarily out of service, or close or substantially modify a storage facility
or other area regulated by Chapter 27 of the International Fire Code.
(e) Private fire hydrants. A permit is required for the installation or modification of
private fire hydrants and their systems.
(f) Standpipe systems. A permit is required for the installation, modification, or
removal from service of a standpipe system. Maintenance performed in accordance with
this chapter is not considered a modification and does not require a permit.
FOR REFERERENCE ONLY, NOT UP FOR PLANNING COMMISSION VOTE
(g) Special permits. In addition to the required permits, the following permits are
required for the following installation and/or repairs; vinyl siding, insulation, roofing, floor
covering/carpet, masonry, drywall, carpentry, stucco, paint/wallpaper, low voltage
electrical, and elevators., landscape/site development.
(B) Work exempt from permit.
(1) Exemptions from permit requirements of this chapter shall not be deemed to grant
authorization for any work to be done in any manner in violation of the provisions of this
chapter or any other laws or ordinances of this Town. Permits shall not be required for the
following:
(a) Building.
1. One-story detached accessory structures used as tool and storage sheds,
playhouses and similar uses, provided the floor area does not exceed 120 square feet (11
m2).
2. Fences not over six feet (1829 mm) high.
3. Water tanks supported directly on grade if the capacity does not exceed 5,000
gallons (18,925 L) and the ratio of height to diameter or width does not exceed 2:1.
4. Retaining walls that are not over four feet (1219 mm) in height measured from
the bottom of the footing to the top of the wall, unless supporting a surcharge or
impounding Class I, II, or IIIA liquids.
5. Sidewalks and driveways not more than 30 inches (762 mm) above adjacent
grade, and not over any basement or story below and are not part of an accessible route.
6. Temporary motion picture, television and theater stage sets and scenery.
7. Prefabricated swimming pools accessory to a Group R-3 occupancy that are less
than 24 inches (610 mm) deep, do not exceed 5,000 gallons (19,000 L) and are installed
entirely above ground.
8. Shade cloth structures constructed for nursery or agricultural purposes, and not
including service systems.
9. Swings and other playground equipment.
10. Nonfixed and movable fixtures, cases, racks, counters, and partitions not over
five feet nine inches (1753 mm) in height.
11. Window awnings supported by an exterior wall that do not project more than
54 inches (1372 mm) from the exterior wall and do not require additional support.
(b) Electrical.
FOR REFERERENCE ONLY, NOT UP FOR PLANNING COMMISSION VOTE
1. Repairs and maintenance. Minor repair work, including the replacement of lamps
or the connection of approved portable electrical equipment to approved permanently
installed receptacles.
2. Radio and television transmitting stations. The provisions of this chapter shall not
apply to electrical equipment used for radio and television transmissions but do apply to
equipment and wiring for a power supply and the installation of towers and antennas.
3. Temporary testing systems. A permit shall not be required for the installation of
any temporary system required for the testing or servicing of electrical equipment or
apparatus.
(c) Gas.
1. Portable gas equipment of all types that is not connected to a fixed fuel piping
system.
2. Replacement of any minor part that does not alter approval of equipment or make
such equipment unsafe.
3. Portable fuel cell appliances that are not connected to a fixed piping system and
are not interconnected to a power grid.
(d) Mechanical.
1. Portable heating appliance.
2. Portable ventilation equipment.
3. Portable cooling unit.
4. Steam, hot or chilled water piping within any heating or cooling equipment
regulated by this chapter.
5. Replacement of any part that does not alter its approval or make it unsafe.
6. Portable evaporative cooler.
7. Self-contained refrigeration system containing ten pounds (five kg) or less of
refrigerant and actuated by motors of one horsepower (746 W) or less.
8. Portable-fuel-cell appliances that are not connected to a fixed piping system and
are not interconnected to a power grid.
(e) Plumbing.
1. The stopping of leaks in drains, water, soil, waste or vent pipe, provided, however,
that if any concealed trap, drain pipe, water, soil, waste or vent pipe becomes defective and
it becomes necessary to remove and replace the same with new material, such work shall
be considered as new work and a permit shall be obtained and inspection made as
provided in this chapter.
FOR REFERERENCE ONLY, NOT UP FOR PLANNING COMMISSION VOTE
2. The clearing of stoppages or the repairing of leaks in pipes, valves or fixtures and
the removal and reinstallation of water closets, provided such repairs do not involve or
require the replacement or rearrangement of valves, pipes, or fixtures.
(f) Energy. The following need not comply provided the energy use of the building is
not increased:
1. Storm windows installed over existing fenestration.
2. Glass only replacements in an existing sash and frame.
3. Construction where the existing roof, wall or floor cavity is not exposed.
(2) Emergency repairs. Where equipment replacements and repairs must be
performed in an emergency situation, the permit application shall be submitted within the
next working business day to the Building Official.
(3) Repairs. Application or notice to the Building Official is not required for ordinary
repairs to structures, replacement of lamps or the connection of approved portable
electrical equipment to approved permanently installed receptacles. Such repairs shall not
include the cutting away of any wall, partition or portion thereof, the removal or cutting of
any structural beam or load-bearing support, or the removal or change of any required
means of egress, or rearrangement of parts of a structure affecting the egress
requirements; nor shall ordinary repairs include addition to, alteration of, replacement or
relocation of any standpipe, water supply, sewer, drainage, drain leader, gas, soil, waste,
vent or similar piping, electric wiring or mechanical or other work affecting public health
or general safety.
(4) Public service agencies. A permit shall not be required for the installation,
alteration, or repair of generation; transmission, distribution or metering or other related
equipment that is under the ownership and control of public service agencies by
established right.
(C) Application for permit.
(1) Filing of application. To obtain a permit, the applicant shall first file an application
therefore in writing on a form furnished by the Department of Building Services for that
purpose. Such application shall:
(a) Identify and describe the work to be covered by the permit for which application
is made;
(b) Describe the land on which the proposed work is to be done by address and tax
map number (TMS) or property identification number (PID);
(c) Indicate the use and occupancy for which the proposed work is intended;
(d) Be accompanied by construction documents and other information as required in
§ 150.06.
(e) State the valuation of the proposed work.
FOR REFERERENCE ONLY, NOT UP FOR PLANNING COMMISSION VOTE
(f) Be signed by the applicant, or the applicant’s authorized agent.
(g) Submit such other data and information as required by the Building Official.
(2) Action on application. The Building Official shall examine or cause to be examined
applications for permits and amendments thereto within a reasonable time after filing. If
the application or the construction documents do not conform to the requirements of
pertinent laws, the Building Official shall reject such application in writing, stating the
reasons, therefore. If the Building Official is satisfied that the proposed work conforms to
the requirements of this chapter and laws and ordinances applicable thereto, the Building
Official shall issue a permit therefore as soon as practicable.
(3) Time limitation of application. An application for a permit for any proposed work
shall be deemed to have been abandoned 180 days after the date of filing, unless such
application has been pursued in good faith or a permit has been issued; except that the
Building Official is authorized to grant one or more extensions of time for additional
periods not exceeding 90 days each. The extension shall be requested in writing and
justifiable cause demonstrated.
(D) Validity of permit. The issuance or granting of a permit shall not be construed to be a
permit for, or an approval of, any violation of any of the provisions of this chapter or of any
other ordinance of the Town. Permits presuming to give authority to violate or cancel the
provisions of this chapter or other ordinances of the Town shall not be valid. The issuance
of a permit based on construction documents and other data shall not prevent the Building
Official from requiring the correction of errors in the construction documents and other
data. The Building Official is also authorized to prevent occupancy or use of a structure
where in violation of this chapter or of any other ordinances of this Town.
(E) Expiration. Every permit issued shall become invalid unless the work on the site
authorized by such permit is commenced within 180 days after its issuance, or if the work
authorized on the site by such permit is suspended or abandoned for a period of 180 days
after the time the work is commenced. The Building Official is authorized to grant, in
writing, one or more extensions of time, for periods not more than 180 days each. The
extensions shall be requested in writing and justifiable cause demonstrated.
(F) Suspension or revocation. The Building Official is authorized to suspend or revoke a
permit issued under the provisions of this chapter wherever the permit is issued in error or
on the basis of incorrect, inaccurate, or incomplete information, or in violation of any
ordinance or regulation or any of the provisions of this chapter.
(G) Placement of permit. The building permit or copy shall be kept on the site for the
work until the completion of the project at an accessible and visible location.
(H) Responsibility. It shall be the duty of every person who performs work for the
installation or repair of building systems, for which this chapter is applicable, to comply
with this chapter.
FOR REFERERENCE ONLY, NOT UP FOR PLANNING COMMISSION VOTE
(I) Manufactured housing permits. In order for a permit to be issued to install a
manufactured home in the Town, a copy of the current license of the installer or contractor,
issued by the South Carolina Manufactured Housing Board, must be submitted with the
application for the permit. If a retail dealer is installing the home, a current copy of the
retail dealer’s license, issued by the South Carolina Manufactured Housing Board, must be
submitted with the application for the permit. The installer, contractor, or dealer may
submit an electronic copy of the license, in an acceptable format such as JPEG or PDF, by
email, or through the online submittal system in place of a copy.
(J) Unauthorized tampering. Signs, tags, or seals posted or affixed by the Building Official
shall not be mutilated, destroyed, or tampered with or removed without authorization
from the Building Official.
(Ord. 2016-14, passed 1-19-2017) Penalty, see § 150.99
§ 150.06 CONSTRUCTION DOCUMENTS.
(A) Submittal documents.
(1) Submission of documents.
(a) One paper set of construction documents, statement of special inspections and
other data, and one electronic set of these documents, shall be submitted in two or more
sets with each permit application. The construction documents shall be prepared by a
registered design professional where required by the statutes of the Town in which the
project is to be constructed. Where special conditions exist, the Building Official is
authorized to require additional construction documents to be prepared by a registered
design professional.
(b) Exception: The Building Official is authorized to waive the submission of
construction documents and other data not required to be prepared by a registered design
professional if it is found that the nature of the work applied for is such that review of
construction documents is not necessary to obtain compliance with this chapter.
(2) Information on construction documents. Construction documents shall be
dimensioned and drawn upon suitable material. Electronic media documents are permitted
to be submitted when approved by the Building Official. Construction documents shall be of
sufficient clarity to indicate the location, nature and extent of the work proposed and show
in detail that it will conform to the provisions of this chapter and relevant laws, ordinances,
rules, and regulations, as determined by the Building Official.
(a) Fire protection system shop drawings. Shop drawings for the fire protection
system(s) shall be submitted to indicate conformance with this chapter and the
construction documents and shall be approved prior to the start of system installation.
Shop drawings shall contain all information as required by the referenced installation
standards in Chapter 9 of the IBC.
FOR REFERERENCE ONLY, NOT UP FOR PLANNING COMMISSION VOTE
(b) Manufacturer’s installation instructions. The manufacturer’s installation
instructions, as required by this chapter, shall be available on the job site at the time of
inspection.
(3) Means of egress. The construction documents shall show in sufficient detail the
location, construction, size, and character of all portions of the means of egress in
compliance with the provisions of this chapter. In other than occupancies in groups R-2, R-
3, and 1-1, the construction documents shall designate the number of occupants to be
accommodated on every floor, and in all rooms and spaces.
(4) Exterior wall envelope.
(a) Construction documents for all buildings shall describe the exterior wall envelope
in sufficient detail to determine compliance with this chapter. The construction documents
shall provide details of the exterior wall envelope as required, including flashing,
intersections with dissimilar materials, corners, end details, control joints, intersections at
roof, eaves, or parapets, means of drainage, water-resistive membrane, details around
openings and wind borne debris protection systems.
(b) The construction documents shall include manufacturer’s installation instructions
that provide supporting documentation that the proposed penetration and opening details
described in the construction documents maintain the weather resistance of the exterior
wall envelope. The supporting documentation shall fully describe the exterior wall system,
which was tested, where applicable, as well as the test procedure used.
(5) Energy requirements. Details shall include, but are not limited to, insulation
materials and their R-values; fenestration U-factors and SHGCs; system and equipment
efficiencies, types, sizes, and controls; duct sealing, insulation and location; and air sealing
details.
(B) Site plan. The construction documents submitted with the application for permit
shall be accompanied by a site plan showing, to an engineer’s scale, the size and location of
new construction and existing structures on the site, distances from lot lines, the
established street grades and the proposed finished grades and, as applicable, flood hazard
areas, floodways, and design flood elevations; and it shall be drawn in accordance with an
accurate boundary line survey. In the case of demolition, the site plan shall show
construction to be demolished and the location and size of existing structures and
construction that are to remain on the site or plot. The Building Official is authorized to
waive or modify the requirement for a site plan when the application for permit is for
alteration or repair or when otherwise warranted.
(C) Examination of documents. The Building Official shall examine or cause to be
examined the accompanying construction documents and shall ascertain by such
examinations whether the construction indicated and described is in accordance with the
requirements of this chapter and other pertinent laws or ordinances.
(1) Approval of construction documents. When the Building Official issues a permit, the
construction documents shall be approved, in writing or by stamp, as “Reviewed for Code
FOR REFERERENCE ONLY, NOT UP FOR PLANNING COMMISSION VOTE
Compliance.” One electronic set of construction documents so reviewed shall be retained
by the Building Official. The Building Official may request that an approved paper set of
construction documents be kept at the site of work until a Certificate of Occupancy has
been issued.
(2) Previous approvals. This chapter shall not require changes in the construction
documents, construction, or designated occupancy of a structure for which a lawful permit
has been heretofore issued or otherwise lawfully authorized, and the construction of which
has been pursued in good faith within 180 days after the effective date of this chapter and
has not been abandoned. Approvals made by Charleston County, on behalf of the Town of
James Island, shall be completed by Charleston County Building Inspection Services. After
180 days from issuance of approval by Charleston County, the Building Official may require
a new application be made to the Town of James Island, and may waive any additional fees,
in order to issue approval from the Town instead of Charleston County. This provision
shall be in effect only during the initial 180-day period after the County is no longer issuing
reviews and approvals on the Town’s behalf. After this period, all previous approvals shall
be submitted as a new application.
(3) Phased approval. The Building Official is authorized to issue a permit for the
construction of foundations or any other part of a building or structure before the
construction documents for the whole building or structure have been submitted, provided
that adequate information and detailed statements have been filed complying with
pertinent requirements of this chapter. The holder of such permit for the foundation or
other parts of a building or structure shall proceed at the holder’s own risk with the
building operation and without assurance that a permit for the entire structure will be
granted.
(4) Design professional in responsible charge.
(a) General.
1. When it is required that documents be prepared by a registered design
professional, the Building Official shall be authorized to require the owner to engage and
designate on the building permit application a registered design professional who shall act
as the registered design professional in responsible charge. If the circumstances require,
the owner shall designate a substitute registered design professional in responsible charge
who shall perform the duties required of the original registered design professional in
responsible charge. The Building Official shall be notified in writing by the owner if the
registered design professional in responsible charge is changed or is unable to continue to
perform the duties.
2. The registered design professional in responsible charge shall be responsible for
reviewing and coordinating submittal documents prepared by others, including phased and
deferred submittal items, for compatibility with the design of the building.
3. Where structural observation is required by the IBC, the statement of special
inspections shall name the individual or firms who are to perform structural observation
and describe the stages of construction at which structural observation is to occur.
FOR REFERERENCE ONLY, NOT UP FOR PLANNING COMMISSION VOTE
(b) Deferred submittals.
1. For the purposes of this section, deferred submittals are defined as those portions
of the design that are not submitted at the time of the application and that are to be
submitted to the Building Official within a specified period.
2. Deferral of any submittal items shall have the prior approval of the Building
Official. The registered design professional in responsible charge shall list the deferred
submittals on the construction documents for review by the Building Official.
3. Documents for deferred submittal items shall be submitted to the registered
design professional in responsible charge who shall review them and forward them to the
Building Official with a notation indicating that the deferred submittal documents have
been reviewed and been found to be in general conformance to the design of the building.
The deferred submittal items shall not be installed until the design and submittal
documents have been approved by the Building Official.
(D) Amend construction documents. Work shall be installed in accordance with the
approved construction documents, and any changes made during construction that are not
in compliance with the approved construction documents shall be resubmitted for
approval as an amended set of construction documents.
(E) Retention of construction documents. One set of approved construction documents
shall be retained by the Building Official for a period of not less than 180 days from date of
completion of the permitted work, as required by state, local laws or in accordance with the
Town records retention schedule.
(Ord. 2016-14, passed 1-19-2017) Penalty, see § 150.99
§ 150.07 TEMPORARY STRUCTURES AND USES.
(A) General. The Building Official is authorized to issue a permit for temporary
structures and temporary occupancy/uses. Such permits shall be limited as to time of
service but shall not be permitted for more than 180 days. The Building Official is
authorized to grant extensions for demonstrated cause.
(B) Conformance. Temporary structures and uses shall conform to the structural
strength, fire safety, means of egress, accessibility, light, ventilation, and sanitary
requirements of this code as necessary to ensure public health, safety, and general welfare.
(C) Temporary power. The Building Official is authorized to give permission to
temporarily supply and use power in part of an electric installation before such installation
has been fully completed and the final certificate of completion has been issued. The part
covered by the temporary certificate shall comply with the requirements specified for
temporary lighting, heat, or power in the National Electrical Code.
FOR REFERERENCE ONLY, NOT UP FOR PLANNING COMMISSION VOTE
(D) Termination of approval. The Building Official is authorized to terminate such permit
for a temporary structure or use and to order the temporary structure or use to be
discontinued.
(Ord. 2016-14, passed 1-19-2017) Penalty, see § 150.99
§ 150.08 FEES.
(A) Payment of fees. A permit shall not be valid until the permit, contractor
licenselicense verification/registration (if applicable), and/or business license, and
other fees as prescribed by law have been paid, nor shall an amendment to a permit
be released until the additional fees, if any, have been paid.
(B) Contractor LLR License Verification/Registration. Any permit application requiring a
South Carolina contractor’s license (as prescribed by the South Carolina Labor, Licensing,
and Registration) shall pay a fee which covers the research required to review the
licensee's current registration status prior to permit issuance.
[1] LLR License Verification/Registration Fee: $10.00
[2] Non-LLR Licensed Contractors Verification/Registration Fee: $50.00
(CB) Schedule of permit fees. On buildings, structures, electrical, gas, mechanical, and
plumbing systems or alterations requiring a permit, a fee for each permit shall be paid as
required, in accordance with the schedule as established by the governing authority.
(DC) Building permit valuations. The applicant for a permit shall provide an estimated
permit value at the time of application. Permit valuations shall include total value of work,
including materials and labor, for which the permit is being issued, such as electrical, gas,
mechanical, plumbing equipment, and permanent systems. If, in the opinion of the Building
Official, the valuation is underestimated on the application, the permit shall be denied,
unless the applicant can show detailed estimates to meet the approval of the Building
Official. The final building permit valuation shall be set by the Building Official.
(D) Work commencing before permit issuance. Any person who commences any work on
a building or structure before obtaining the necessary permits shall be subject to a double
fee.
(E) Related fees. The payment of the fee for the construction, alteration, removal, or
demolition for work done in connection to or concurrently with the work authorized by a
permit shall not relieve the applicant or holder of the permit from the payment of other
fees that are prescribed by law.
(F) Refunds.
(1) There shall be no refund unless it is due to a Town mistake. All refunds caused by a
Town mistake are to be referred to the Building OfficialTown Administrator for processing.
FOR REFERERENCE ONLY, NOT UP FOR PLANNING COMMISSION VOTE
(2) Exceptions: Requests for refunds by the applicant’s mistake may be made up to
financial close of books (3:304:00 pm) on the day the funds are paid.
(G) Permit fees. Fees shall be as established by the Town of James Island, as set forth
below in this section.
Total Valuation Fee
Total Valuation Fee
$1,000.00 and less No fee, unless an inspection is required, in which case a permit is
required and a $75.00$50.00 fee shall be charged
$1,000.00 to
$2,000.00
$75.00$50.00
$2,001.00 to
$50,000.00
$75.00 $50.00 for the first $2,000.00 + $4.50$4.00 per $1,000.00
$50,001.00 to
$100,000.00
$291.00$242.00 for the first $50,000.00 + $4.50$3.75 per
$1,000.00
$100,001.00 to
$300,000.00
$516.00$429.50 for the first $100,000.00 +$4.00$3.50 per
$1,000.00
$300,001.00 to
$500,000.00
$1,316.00$1,129.50 for the first $300,000.00 +$3.75$3.35 per
$1,000.00
$500,001.00 and up $2,066.00$1,799.50 for the first $500,000.00 + $3.50$3.00 per
$1,000.00
(b) Working without permits: Double fee.
(3) Other permit fees.
Permit fee when the contractor is working as a subcontractor for the following activities:
painting/wallpaper; floor covering, drywall (unless part of fire related assembly), trim,
cabinets, shelving, countertops, closet systems, and shower glassdoor, and vinyl siding.
$25.00
Exceptions:
(a) When permits are issued for work being done as the prime contractor, the fees shall
be based on construction value as in division (G)(2) above, valuation chart, for the
appropriate type of work being performed.
FOR REFERERENCE ONLY, NOT UP FOR PLANNING COMMISSION VOTE
(b) Prime contractors permitted and performing subcontractor work utilizing their full-
time regular hourly employees will be required to notify the Building Official of what work
they are self-performing. be issued trade permits with no fee.
(4) Manufactured housing permit fees.
For setup on a new or existing site
$250.00$100.00
Note: Fees for modular construction as defined by the South Carolina Modular Construction
Act shall be based upon the fee schedule for permits based on construction valuations.
(5) Inspection fees.
(a) Reinspection When a reinspection fee is required, an additional fee
of $75.00$50.00 will be charged for each inspection.
(b) Minimum permit or
inspection fee
$75.00$50.00
(c) Floodplain management
compliance inspection
$100.00$75.00
(d) Hazardous occupant
permits
$100.00
(e) Fireworks stand permits $75.00$50.00
(f) Structural moving permit
fee
$100.00
(g) Demolition permit fee $75.00$50.00
(6) Other fees.
(a)
Plan review fees:
One-half permit fee based on construction valuations.
(b)
Construction in flood zones/filing fee:
FOR REFERERENCE ONLY, NOT UP FOR PLANNING COMMISSION VOTE
$25.00$20.00
Note: If a prime contractor has paid a flood zone filing fee, the subcontractor working for
the prime contractor will not be charged an additional filing fee.
(c)
Fees for replacement of placards shall be
$25.00
(d) (d)
Variance/appeal application fee
$100.00
Note: Application fees for appeals successfully granted by the Construction Board of
Adjustment and Appealsthe designated board shall be applied to the required permit or
plan review fees associated with the appealed project, or if all fees have been paid, the fees
shall be refunded reimbursed to the applicant.
(e)
Vehicle decal fee
$6.00/vehicle/set
(f)
Annual vehicle
$3.00
(7) Penalties. Where work for which a permit is required by this chapter is started or
proceeded prior to obtaining said permit, the fees herein specific shall be doubled, but the
payment of such double fee shall not relieve any persons from fully complying with the
requirements of this chapter in the execution of work, nor from any other penalties
prescribed herein.
(Ord. 2016-14, passed 1-19-2017)
Editor’s Note:
The specific fees set forth in this section are those of Charleston County Ordinance 1840,
adopted by the county on January 20, 2015, which was adopted by the town’s Ordinance
2016-14 on January 19, 2017
FOR REFERERENCE ONLY, NOT UP FOR PLANNING COMMISSION VOTE
§ 150.09 INSPECTIONS.
(A) General. Construction or work for which a permit is required, including safety
inspections, shall be subject to inspection by the Building Official and such construction or
work shall remain accessible and exposed for inspection purposes until approved.
Approval as a result of an inspection shall not be construed to be an approval of a violation
of the provisions of this chapter or of other ordinances of the Town. Inspections presuming
to give authority to violate or cancel the provisions of this chapter or of other ordinances of
the Town shall not be valid. It shall be the duty of the permit applicant to cause the work to
remain accessible and exposed for inspection purposes. Neither the Building Official nor
the Town shall be liable for the expense entailed in the removal or replacement of any
material required to allow inspection.
(B) Preliminary inspection. Before issuing a permit, the Building Official is authorized to
examine or cause to be examined building, structures, and sites for which an application
has been filed.
(C) Required inspections. The Building Official, upon notification, shall make the
inspections set forth in divisions (C)(1) through (C)(12) below.
(1) Footing and foundation inspection. Footing and foundation inspections shall be
made after excavations for footings are complete and any required reinforcing steel is in
place. For concrete foundations, any required forms shall be in place prior to inspection.
Materials for the foundation shall be on the job, except where concrete is ready mixed in
accordance with ASTM C 94, the concrete need not be on the job.
(2) Concrete slab and under-floor inspection. Concrete slab and under-floor
inspections shall be made after in-slab or under-floor reinforcing steel and building service
equipment, conduit, piping accessories and other ancillary equipment items are in place,
but before any concrete is placed or floor sheathing installed, including the sub floor.
(3) Lowest floor elevation. In flood hazard areas, upon placement of the lowest floor
including the basement, and prior to further vertical construction, an elevation certificate
as required in Chapter 151, Town Regulations Concerning Flood Damage Prevention, shall
be submitted to the Building Official.
(4) Plumbing, mechanical, gas and electrical systems inspection.
(a) Rough inspection of plumbing, mechanical, gas and electrical systems shall be
made prior to covering or concealment, before fixtures or appliances are set or installed,
and prior to framing inspection.
(b) Exception: Back-filling of ground-source heat pump loop systems tested in
accordance with the International Mechanical Code prior to inspection shall be permitted.
(5) Frame and masonry inspection. Framing inspections shall be made after the roof
deck or sheathing, all framing, fire blocking, bracing and masonry are in place and pipes,
FOR REFERERENCE ONLY, NOT UP FOR PLANNING COMMISSION VOTE
chimneys, and vents to be concealed are complete and the rough electrical, plumbing,
heating wires, pipes and ducts are approved.
(6) Fire-resistance-rated construction inspection. Where fire-resistance-rated
construction is required between dwelling units or due to location on property, the
Building Official shall require an inspection of such construction after all lathing and/or
wallboard is in place, but before any plaster is applied, or before wall-board joints and
fasteners are taped and finished.
(7) Reinforced masonry, insulating concrete form (ICF) and conventionally formed
concrete wall inspection. Reinforced masonry walls, insulating concrete form (ICF) walls
and conventionally formed concrete walls shall be inspected after plumbing, mechanical,
and electrical systems are embedded within the walls, reinforcing steel is in place and prior
to placement of grout or concrete. Inspection shall verify the correct size, location, spacing,
and lapping of reinforcing. For masonry walls, inspection shall also verify that the location
of grout cleanouts and size of grout spaces comply with the requirements of this chapter.
(8) Fire-resistant penetrations. Protection of joints and penetrations in fire-resistance-
rated assemblies shall not be concealed from view until inspected and approved.
(9) Energy efficiency inspections. Inspections shall be made to determine compliance
with the International Energy Conservation Code and shall include, but not be limited to
inspections for: envelope insulation R and U values, fenestration U value, duct system R
value, and HVAC and water-heating equipment efficiency.
(10) Other inspections. In addition to the inspections specified above, the Building
Official is authorized to make or require other inspections of any construction work to
ascertain compliance with the provisions of this chapter and other laws that are enforced
by the Building Official.
(11) Special inspections. Special inspections shall be in compliance with the applicable
provisions of this chapter.
(12) Final inspection. The final inspection shall be made after all work required by the
applicable permits are completed.
(D) Inspection agencies. The Building Official is authorized to accept reports of approved
inspection agencies, provided such agencies satisfy the requirements as to qualifications
and reliability.
(E) Inspection requests. It shall be the duty of the holder of the building permit or their
duly authorized agent to notify the Building Official when work is ready for inspection. It
shall be the duty of the permit holder to provide access to and means for inspection of such
work that are required by this chapter.
(F) Approval required. Work shall not be done beyond the point indicated in each
successive inspection without first obtaining the approval of the Building Official. The
Building Official, upon notification, shall make the requested inspections and shall either
indicate the portion of the construction that is satisfactory as completed, or notify the
FOR REFERERENCE ONLY, NOT UP FOR PLANNING COMMISSION VOTE
permit holder or his or her agent wherein the same fails to comply with this chapter. Any
portions that do not comply shall be corrected and such portion shall not be covered or
concealed until authorized by the Building Official.
(Ord. 2016-14, passed 1-19-2017) Penalty, see § 150.99
§ 150.10 CERTIFICATE OF OCCUPANCY.
(A) Use and occupancy.
(1) No building or structure shall be used or occupied, and no change in the existing
occupancy classification of a building or structure or portion thereof shall be made until the
Building Official has issued a certificate of occupancy therefore as provided herein.
Issuance of a certificate of occupancy shall not be construed as an approval of a violation of
the provisions of this code or of other ordinances of the Town. Certificates presuming to
give authority to violate or cancel the provisions of this chapter or other ordinances of the
Town shall not be valid.
(2) Exception: Certificates of occupancy are not required for work exempt from
permits.
(B) Change in use. Changes in the character or use of an existing structure shall not be
made except in compliance with this chapter.
(C) Certificate issued. After the Building Official Inspects the building or structure and
finds no violations of the provisions of this chapter or other laws that are enforced by the
Department of Building Services, the Building Official shall issue a certificate of occupancy
or certificate of completion that contains the following:
(1) The permit number.
(2) Permit issue date.
(3) The address and tax map (TMS) number or property identification description
(PID) of the structure.
(4) The name of the contractor or permit holder.
(5) A statement that describes the structure or portion thereof has been inspected for
compliance with the requirements of this chapter.
(6) The name of the Building Official.
(7) The type of construction if applicable.
(8) The design occupant load if applicable.
(9) Flood zone information.
(10) Any special stipulations and conditions of the building permit.
FOR REFERERENCE ONLY, NOT UP FOR PLANNING COMMISSION VOTE
(D) Temporary occupancy. The Building Official is authorized to issue a temporary
certificate of occupancy before the completion of the entire work covered by the permit,
provided that such portion or portions shall be occupied safely. The Building Official shall
set a time period during which the temporary certificate of occupancy is valid.
(E) Revocation. The Building Official is authorized to, in writing, suspend or revoke a
certificate of occupancy or completion issued under the provisions of this chapter
wherever the certificate is issued in error, or on the basis of incorrect information supplied,
or where it is determined that the building or structure or portion thereof is in violation of
any ordinance or regulation or any of the provisions of this chapter.
(Ord. 2016-14, passed 1-19-2017) Penalty, see § 150.99
§ 150.11 SERVICE UTILITIES.
(A) Connection of service utilities. No person shall make connections from a utility,
source of energy, fuel or power to any building or system that is regulated by this chapter
for which a permit is required, until released by the Building Official.
(B) Temporary connection. The Building Official shall have the authority to authorize the
temporary connection of the building or system to the utility source of energy, fuel or
power.
(C) Authority to disconnect service utilities. The Building Official shall have the authority
to authorize disconnection of utility service to the building, structure or system regulated
by this chapter and the codes referenced herein in case of emergency where necessary to
eliminate an immediate hazard to life or property. The Building Official shall notify the
serving utility, and wherever possible the owner and occupant of the building, structure, or
service system of the decision to disconnect prior to taking such action. If not notified prior
to disconnecting, the owner or occupant of the building, structure or service system shall
be notified in writing, as soon as practical thereafter.
(Ord. 2016-14, passed 1-19-2017) Penalty, § 150.99
§ 150.12 LICENSING AND REGISTRATION.
(A) Definitions. For the purpose of this section, the following definitions shall apply
unless the context clearly indicates or requires a different meaning.
BURGLAR ALARM SYSTEM. The installation service, maintenance or alteration of a
system that detects intrusion, burglary, and breaking or entering but does not include
home health care signaling devices.
EMPLOYEE. A regularly employed, qualified tradespersons on the premises owned or
operated by the applicant for a permit.
FOR REFERERENCE ONLY, NOT UP FOR PLANNING COMMISSION VOTE
FIRE ALARM SYSTEM. A system or portion of a combination system consisting of
components and circuits arranged to monitor and announce the status of fire alarm or
supervisory signal-initiating devices and to initiate the appropriate response to those
signals.
FIRE SPRINKLER SYSTEM. A system of overhead or underground piping, or both, to
protect the interior or exterior of a building or structure from fire where the primary
extinguishing agent is water and designed in accordance with fire protection engineering
standards. Fire protection sprinkler systems include the following types: water based or
wet-pipe systems, water foam systems, dry-pipe systems, preaction systems, residential
systems, deluge systems, combined dry-pipe and preaction systems, non-freeze systems,
and circulating closed loop systems.
LOW VOLTAGE. A system consisting of an isolating power supply, the low-voltage
luminaries, and associated equipment that are all identified for the use. The output circuits
of the power supply are rated for not more than 25 amperes and operate at 30 volts (42.4
volts peak) or less under all load conditions.
OWNER. The property owner, owner’s parents, sisters and brothers, children of the
owner and owner’s sisters and brothers, and those married to these family members;
however, when actual hardship is caused by these limitations, the Building Official may
waive these requirements.
SIGN OR OUTDOOR ADVERTISING SIGN. Any outdoor sign, display, device, figure,
painting, drawing, message, plaque, poster, billboard, or other thing which is designed,
intended or used to advertise or inform, any part of the advertising or informative contents
of which is visible from any place on the main traveled way of any road, street or highway
for the purpose of this chapter.
SITE CONSTRUCTION WORK. Work is considered the act or process or altering the
natural cover or topography and alters the quality or quantity of stormwater runoff.
SWIMMING POOLS. Any structure intended for swimming, recreational bathing or
wading that contains water over 24 inches (610 mm) deep. This includes in-ground, above-
ground and on-ground pools; hot tubs; spas and fixed-in-place wading pools.
TOWN CONTRACTOR'S LICENSELICENSE VERIFICATION. Duty of permit issuer to verify
aAuthorization for a holder of a South Carolina license or registration issued by the South
Carolina Contractors' Licensing Board, the South Carolina Residential Builders
Commission, or the South Carolina Manufactured Housing Board, or an individual or
company that installs, alters or repairs signs, low-volt electrical systems, or elevators to
contract and/or perform construction work in the Town within the limits prescribed by the
South Carolina Code of Laws or as established by Town ordinance.
TOWN CONTRACTOR'S REGISTRATION. Authorization for a holder of a South Carolina
registration issued by the South Carolina Residential Builders Commission or an individual
or company that installs, alters or repairs swimming pools, signs, low-volt electrical
systems, elevators or landscaping/site development, to contract and/or perform
FOR REFERERENCE ONLY, NOT UP FOR PLANNING COMMISSION VOTE
construction work in the tTown within the limits prescribed by the South Carolina Code of
Laws or as established by the town ordinance.
(B) Town license or registration requiredLicense verification required. Before any
person shall engage in the business of construction, alteration or repairs in any building or
structure in the Town, he or she must obtain a license or registration from the Ttown as
requiredappropriate entity as required by law. It shall be the duty of every contractor or
builder who shall make contracts for erection or construction or repair of a building for
which a permit is required in the Town, and every contractor or builder making such
contracts and subletting the same or any part thereof, to secure a license or registration as
provided herein.
(1) Anyone required to be licensed or registered by the Town as South Carolina LLR
shall present a copy of his or her state license or registration, if required by state statutes. If
the application is satisfactory, a Ttown license or registration shall be issued to the
applicant within the limitations of the state license or registration is required by state
statutes, or as established by the Construction Board of Adjustment and Appeal and upon
payment of the required license and registration fee.
(2) Plumbing and electrical journeymen are limited to working only under a licensed
plumber or licensed electrician and shall not be issued permits.
(C) Grounds for revocation; procedure for filing charges. The Construction Board of
Adjustment and AppealsLicensing Official for the Town may revoke the license or
registrationpermits of any building contractor who is found guilty of fraud or deceit in
obtaining a license or registration, or gross negligence, incompetence, or misconduct in
conducting his business as a contractor. Any person, who prefers charges of gross
negligence, incompetence, or misconduct against any contractor licensed or registered
under the provisions of this division, shall submit such charges in affidavit form and file
same with the Licensing OfficialSecretary of the Construction Board of Adjustment and
Appeals.
(D) License identification. All holders of a license or registration in the town shall display
a current license or registration identification decal issued by the Building Official. This
decal shall be displayed on the left and right sides of work vehicle(s).
(E) Limitations of work by owner. The performance of any kind of construction,
alteration, or repair upon any property by the owner thereof shall be contingent on
verification by the owner of his or her working knowledge of the kind of construction to be
done prior to issuing a permit, such verification to be accomplished by such means as
deemed sufficient by the Building Official. In the event the owner does not qualify as to the
knowledge required to perform the work, the owner must then have a licensed or
registered contractor secure a permit and do the work.
(F) Residential work by owner. Pursuant to S.C. Code, § 40-59-260 as amended, the
following provisions shall apply to homeowners obtaining permits to perform
construction-related work on their own homes:
FOR REFERERENCE ONLY, NOT UP FOR PLANNING COMMISSION VOTE
(1) The owner shall do the construction-related work himself, with his own employees,
or with licensed or registered contractors or individuals;
(2) The structure, group of structures, or appurtenances, including the improvements,
shall be intended for the owner's sole occupancy or occupancy by the owner's family, and
shall not be intended for sale or rent for a minimum of two years after completion or
issuance of a certificate of occupancy;
(3) The term “sale” or “rent” includes an arrangement by which an owner received
compensation in money, provisions, chattel, or labor from the occupancy, or the transfer of
the property or the structures on the property;
(4) The general public shall not have access to this structure;
(5) This section does not exempt a person who is employed by the owner and who acts
in the capacity of a builder of any kind;
(6) The homeowner shall personally appear and sign the building permit application
and shall provide the Town of James Island with a disclosure statement provided by the
Building Official or his designee; and
(7) The owner shall promptly file as a matter of public record a notice with the Register
of Deeds, indexed under the owner’s name in the grantor’s index, stating that the
residential building or structure was constructed by the owner as an unlicensed builder.
(Ord. 2016-14, passed 1-19-2017) Penalty, see § 150.99
§ 150.13 UNSAFE DWELLINGS AND EQUIPMENT.
(A) Authority. The provisions of this section are adopted pursuant to “Building Code” by
S.C. Code § 31-15-310 for municipalities in counties and S.C. Code § 6-9-10.
(B) General. Structures or existing equipment that are or hereafter become unsafe,
unsanitary or deficient because of inadequate means of egress facilities, inadequate light
and ventilation or which constitute a fire hazard or are otherwise dangerous to human life
or the public welfare, or that involve illegal or improper occupancy or inadequate
maintenance, shall be deemed an unsafe condition. Unsafe structures shall be taken down
and removed or made safe, as the Building Official deems necessary and as provided for in
this section.
(1) Investigation and filing of a complaint. Whenever it appears to the Building Official
(on his own motion) that any dwelling is unfit for human habitation, the Building Official
shall, if his preliminary investigation discloses a basis for such charges, issue and cause to
be served upon the owner of and all parties in interest in such dwelling a complaint stating
the charges in that respect and containing a notice that a hearing will be held before the
Building Official or his designated agent at a place therein fixed not less than ten days nor
more than 30 days after the serving of such complaint; that the owner and parties in
interest shall be given the right to file an answer to the complaint and to appear in person
FOR REFERERENCE ONLY, NOT UP FOR PLANNING COMMISSION VOTE
or otherwise and give testimony at the place and time fixed in the complaint; and that the
rules of evidence prevailing in courts of law or equity shall not be controlling in hearings
before the Building Official;
(2) Powers of the Building Official. The Building Official may exercise such powers as
may be necessary or convenient to carry out and effectuate the purposes and provisions of
this section, including the following powers in addition to others herein granted:
(a) To investigate the dwelling conditions in the Town in order to determine which
dwellings therein are unfit for human habitation;
(b) To administer oaths and affirmations, examine witnesses and receive evidence;
(c) To enter upon premises for the purpose of making examinations, provided such
entries be made in such manner as to cause the least possible inconvenience to the persons
in possession;
(d) To appoint and fix the duties of such officers, agents and employees as deemed
necessary to carry out the purposes of this chapter; and
(e) To delegate any of his functions and powers to such officers and agents as he may
designate.
(3) Service of complaints or orders; posting and filing copies. Complaints or orders
issued by the Building Official pursuant to this chapter shall be served upon persons either
personally or by registered mail, but if the whereabouts of such persons is unknown and
cannot be ascertained by the Building Official in the exercise of reasonable diligence and
the Building Official shall make to that effect, then the serving of such complaint or order
upon such persons may be made by publishing it once each week for two consecutive
weeks in a newspaper printed and published in the municipality or, in the absence of such
newspaper, in one printed and published in Charleston County and circulating in the Town
of James Island. A copy of such complaint or order shall be posted in a conspicuous place
on the premises affected by the complaint or order. A copy of such complaint or order shall
also be filed with the clerk of the Magistrate’s Court in which the dwelling is located and
such filing of the complaint or order shall have the same force and effect as other lis
pendens notices provided by law.
(4) Determination of Building Official.
(a) That if, after such notice and hearing, the Building Official determines that the
dwelling under consideration is unfit for human habitation he shall state in writing his
findings of fact in support of such determination and shall issue and cause to be served
upon the owner thereof an order:
1. If the repair, alteration or improvement of the dwelling can be made at a
reasonable cost in relation to the value of the dwelling (as determined by the Building
Official), requiring the owner, within the time specified in the order, to repair, alter or
improve such dwelling to render it fit for human habitation or to vacate and close the
dwelling as a human habitation; or
FOR REFERERENCE ONLY, NOT UP FOR PLANNING COMMISSION VOTE
2. If the repair, alteration, or improvement of the dwelling cannot be made at a
reasonable cost in relation to the value of the dwelling (as determined by the Building
Official), requiring the owner, within the time specified in the order, to remove or demolish
such dwelling;
(b) That, if the owner fails to comply with an order to repair, alter or improve or to
vacate and close the dwelling, the Building Official may cause such dwelling to be repaired,
altered or improved or to be vacated and closed; that the Building Official may cause to be
posted on the main entrance of any dwelling so closed, a placard with the following words:
'This building is unfit for human habitation; the use or occupation of this building for
human habitation is prohibited and unlawful";
(c) That, if the owner fails to comply with an order to remove or demolish the
dwelling, the Building Official may cause such dwelling to be removed or demolished; and
(d) That the amount of the cost of such repairs, alterations, or improvements,
vacating and closing, or removal or demolition by the Building Official shall be a lien
against the real property upon which such cost was incurred and shall be collectible in the
same manner as municipal taxes.
(C) Unsafe conditions.
(1) A vacant structure that is not secured against entry is considered an unsafe
structure.
(2) The building, structure or portion thereof constitutes a fire hazard having received
damage by fire, flood, earthquake, wind, or other cause to the extent that the structural
integrity of the building or structure is less than it was prior to the damage and is less than
the minimum requirement established by this chapter, for new buildings.
(3) Any accessory structure and exterior appendage or portion of the building or
structure, shall be maintained and kept in good repair and sound structural condition and
must be securely fastened, attached, or anchored such that it is capable of resisting wind,
seismic or similar loads must meet the requirements of this chapter.
(4) If for any reason the building, structure or portion thereof is manifestly unsafe or
unsanitary for the purpose for which it is being used.
(5) The building, structure, or portion thereof as a result of decay, deterioration or
dilapidation is likely to fully or partially collapse.
(6) The building, structure or portion thereof has been constructed or maintained in
violation of specific requirements of this chapter.
(7) Any building, structure, or portion thereof that is in such a condition as to
constitute a public nuisance.
(8) The stress in any material, member, or portion thereof, due to all imposed loads
including dead load exceeds the stresses allowed in this chapter for new buildings.
FOR REFERERENCE ONLY, NOT UP FOR PLANNING COMMISSION VOTE
(9) Any means of egress or portion thereof, such as but not limited to fire doors, closing
devices and fire resistive ratings, is in disrepair or in a dilapidated or nonworking condition
such that the means of egress could be rendered unsafe.
(10) Roofs shall be structurally sound and maintained in a safe manner and have no
defects which might admit rain or cause dampness in the walls or interior portion of the
building.
(11) Every inside and outside stair, porch and any appurtenance thereof shall be safe
to use and capable of supporting the load that normal use may cause to be placed thereon,
shall be kept in sound condition, and good repair.
(D) Minimum standards.
(1) Windows and doors. Every window and door shall be substantially weather-tight,
watertight and rodent-proof, and shall be kept in sound working condition and good repair.
(2) Wood surfaces and masonry joints. All exterior wood surfaces, other than decay
resistant woods, shall be protected from the elements and decay by painting or other
protective covering or treatment. All masonry joints shall be sufficiently tuck pointed to
insure water and air tightness.
(3) Skirting. Existing skirting shall be maintained free from broken or missing sections,
pieces or cross members. Skirting shall be securely attached and sized from the ground to
the lower outside perimeter of the structure.
(4) Floors, walls, and ceilings. Every floor, interior wall and ceiling shall be
substantially rodent proof, shall be kept in sound condition and good repair and shall be
safe to use and capable of supporting the load which normal use may cause to be placed
thereon.
(5) Bathroom. Every bathroom shall comply with the light and ventilation
requirements for habitable rooms except that no window or skylight shall be required in
adequately ventilated bathrooms equipped with an approved ventilation system.
(6) Bathroom doors. Privacy of bathrooms shall be afforded by doors complete with
privacy hardware intended by the manufacturer for that purpose.
(7) Electric lights and outlets. Where there is electric service available to the building
structure, every habitable room or space shall contain at least two separate and remote
receptacle outlets. Bedrooms shall have, in addition, at least one wall switch controlled
lighting outlet, in kitchens, two separate circuits and controlled lighting outlets shall be
provided (receptacles rendered inaccessible by appliances fastened in place or by
appliances occupying dedicated space shall not be considered as these required outlets)
and a wall or ceiling lighting outlet controlled by a wall switch shall be provided. Every hall,
water closet compartment, bathroom, laundry room or furnace room shall contain at least
one ceiling-mounted or wall-mounted lighting outlet in every bathroom and laundry room
there shall be provided at least one receptacle outlet. Any new bathroom receptacle outlet
shall have ground fault circuit interrupter protection.
FOR REFERERENCE ONLY, NOT UP FOR PLANNING COMMISSION VOTE
(8) Light on public halls and stairways. Every electrical outlet and fixture, and all
electrical wiring and equipment shall be installed, maintained and connected to a source of
electric power in accordance with the provisions of the electrical code of the Town of James
Island.
(9) Garbage disposal. Every owner or tenant shall dispose of all his garbage and any
other organic waste which might provide food for rodents and all rubbish in a clean and
sanitary manner.
(E) Additional minimum residential standards.
(1) General. No person shall occupy as owner-occupant or let or sublet to another for
occupancy any dwelling or dwelling unit designed or intended to be used for the purpose of
living, sleeping, cooking, or eating therein, nor shall any vacant dwelling building be
permitted to exist which does not comply with the following requirements.
(a) Sanitary facilities. Every dwelling unit shall contain not less than a kitchen sink,
lavatory, tub or shower, and a water closet all in good working condition and properly
connected to an approved water and sewer system. Every plumbing fixture and water and
waste pipe shall be properly installed and maintained in good sanitary working condition
free from defects, leaks, and obstructions.
(b) Location of sanitary facilities. All required plumbing fixtures shall be located
within the dwelling unit and be accessible to the occupants of same. The water closet, tub
or shower and lavatory shall be located in a room affording privacy to the user and such
room shall have a minimum floor space of 30 square feet (2.8 m) with no dimension less
than four feet. (1219 mm). Bathrooms shall be accessible from habitable rooms, hallways,
corridors or other protected or enclosed area.
(c) Hot and cold water supply. Every dwelling unit shall have an adequate supply of
both cold and hot water connected to the kitchen sink, lavatory and tub or shower. All
water shall be supplied through an approved distribution system connected to a potable
water supply.
(d) Water heating facilities. Every dwelling unit shall have water heating facilities
which are property installed and maintained in a safe and good working condition and are
capable of heating water to such a temperature as to permit an adequate amount of water
to be drawn at every required kitchen sink, lavatory basin, bathtub or shower at a
temperature of not less than 120°F (49°C). Such water heating facilities shall be capable of
meeting the requirements when the dwelling or dwelling unit heating facilities required
under the provisions of this chapter are not in operation. Apartment houses may use a
centralized water heating facility capable of heating an adequate amount of water as
required by the International Plumbing Code to not less than 120°F (49°C).
(e) Heating facilities. Every dwelling unit shall have permanent heating facilities
which are properly installed, are maintained in safe and good working conditions, and are
capable of safely and adequately heating all habitable rooms and bathrooms. Where a
FOR REFERERENCE ONLY, NOT UP FOR PLANNING COMMISSION VOTE
central heating system is not provided, each dwelling unit shall be provided with facilities
whereby heating appliances may be connected.
(f) Kitchen facilities. Every dwelling unit shall contain a kitchen equipped with the
following minimum facilities:
1. Food preparation surfaces impervious to water and free of defects which could
trap food or liquid.
2. Shelving, cabinets, or drawers for the storage of food and cooking and eating
utensils, all of which shall be maintained in good repair.
3. Freestanding or permanently installed cook stove. Portable electric cooking
equipment shall not fulfill this requirement. Portable cooking equipment employing flame
shall be prohibited.
4. Mechanical refrigeration equipment for the storage of perishable foodstuffs.
Exception: Nothing herein shall preclude a written agreement between the owner and
tenant that the tenant will furnish mechanical refrigeration equipment and/or a cook stove
as required in this section. It shall be an affirmative defense available to an owner charged
with a violation of this section if such an agreement exists.
(g) Smoke detector and/or carbon monoxide systems. Every dwelling unit shall be
provided with an approved listed detector, installed in accordance with the manufacturer’s
recommendations and listing. When activated, the detector shall provide an audible alarm.
The detector shall be tested in accordance with and meet the requirements of UL 217,
single and multiple station smoke detectors.
(2) Minimum requirements for light and ventilation.
(a) Windows.
1. Every habitable room shall have at least one window or skylight facing directly to
the outdoors. The minimum total window area, measured between stops, for every
habitable room shall be 8% of the floor area of such room. Whenever wall or other portions
of structures face a window of any such room and such light-obstruction structures are
located less than three feet (914 mm) from the window and extend to a level above that of
the ceiling of the room, such a window shall not be deemed to face directly to the required
minimum total window area. Whenever the only window in a room is a skylight-type
window in the top of such room, the total window area of such skylight shall equal at least
15% of the total floor area of such room.
2. Exception: Where adequate artificial light is provided and controlled by a wall
switch.
(b) Ventilation. The total of openable window area in every habitable space shall
equal to at least 45% of the minimum window area or shall have other approved,
equivalent ventilation. Year round mechanically ventilating conditioned air systems may be
substituted for windows, as required herein, in rooms other than rooms used for sleeping
purposes. Window type air-conditioning units are not included in this exception. Where
FOR REFERERENCE ONLY, NOT UP FOR PLANNING COMMISSION VOTE
mechanical year round ventilation is not provided screens over opening must be in good
working condition. Every habitable room shall have at least one window or skylight which
can be easily opened or such other device as will adequately ventilate the room.
(3) Minimum dwelling space requirements.
(a) Required space in dwelling unit. Every dwelling unit shall contain at least 150
square feet (13.9 m2) of floor space for the first occupant thereof and at least an additional
100 square feet (9.3 m2) of floor area per additional occupant. The floor area shall be
calculated on the basis of the total area of all habitable rooms.
(b) Required space in sleeping rooms. In every dwelling unit, every room occupied for
sleeping purposes by one occupant shall contain at least 70 square feet of floor space, and
every room occupied for sleeping purposes by more than one occupant shall contain at
least 50 square feet (4.6 m2) of floor space for each occupant thereof.
(c) Minimum ceiling height. Habitable (space) rooms other than kitchens, storage
rooms and laundry rooms shall have a ceiling height of not less than seven feet (2134 mm).
Hallways, corridors, bathrooms, water closet rooms and kitchens shall have a ceiling height
of not less than seven feet (2134 mm) measured to the lowest projection from the ceiling. If
any room in a building has a sloping ceiling, the prescribed ceiling height for the room is
required in only one-half the room area. No portion of the room measuring less than five
feet (1524 mm) from the finished floor to the finished ceiling shall be included in any
computation of the minimum room area.
(d) Occupancy of dwelling unit below grade. No basement or cellar space shall be
used as a habitable room or dwelling unit unless:
1. The floor and walls are impervious to leakage of underground and surface runoff
water and are insulated against dampness;
2. The total window area in each room is equal to at least the minimum window
area size as required;
3. Such required minimum window area is located entirely above the grade of the
ground adjoining such window area; and
4. The total of openable window area in each room is equal to at least the minimum
as required, except where some other device affording adequate ventilation is supplied.
(4) Sanitation requirements.
(a) Sanitation. Every owner of a multiple dwelling shall be responsible for
maintaining in a clean and sanitary condition the shared or common areas of the dwelling
and premises thereof.
(b) Cleanliness. Every tenant of a dwelling unit shall keep in a clean and sanitary
condition that part of the dwelling, dwelling unit and premises thereof which he occupies,
or which is provided for his particular use.
FOR REFERERENCE ONLY, NOT UP FOR PLANNING COMMISSION VOTE
(c) Extermination. Every owner of a single dwelling building and every owner of a
building containing two or more dwelling units shall be responsible for the extermination
of any insects, rodents, wood-destroying organisms, or other pests within the building or
premises.
(5) Rooming houses.
(a) Compliance exceptions. No person shall operate a rooming house or shall occupy
or let to another for occupancy any rooming unit in any rooming house, except in
compliance with the provisions of every section of this chapter.
(b) Water closet, lavatory and bath facilities. At least one flush water closet, lavatory
basin, and bathtub or shower, properly connected to a water and sewer system and in good
working condition, shall be supplied for each four rooms within a rooming house wherever
such facilities are shared. All such facilities shall be located on the floor they serve within
the dwelling so as to be reasonably accessible from a common hall or passageway to all
persons sharing such facilities.
(c) Water heater required. Every lavatory basin and bathtub or shower shall be
supplied with hot water at all times.
(d) Minimum floor area for sleeping purposes. Every room occupied for sleeping
purposes by one person shall contain at least 70 square feet (6.5 m2) of floor space and
every room occupied for sleeping purposes by more than one person shall contain at least
50 square feet (4.6 m2) of floor space for each occupant thereof.
(e) Exit requirements. Every rooming unit shall have safe, unobstructed means of
egress leading to safe and open space at ground level, as required by the building code.
(f) Sanitary conditions. The operator of every rooming house shall be responsible for
the sanitary maintenance of all walls, floors, and ceilings, and for maintenance of a sanitary
condition in every other part of the rooming house, and shall be further responsible for the
sanitary maintenance of the entire premises where the entire structure or building is
leased or occupied by the operator.
1. The building shall be ordered repaired in accordance with this chapter or
demolished in accordance with procedures as established within this chapter.
2. If the building or structure poses an immediate hazard to life or to the safety of
the public it shall be ordered vacated immediately.
(Ord. 2016-14, passed 1-19-2017) Penalty, see § 150.99
§ 150.14 BOARD DESIGNATED TO HEAR APPEALS OF DECISIONS MADE BY THE BUILDING
OFFICIAL.CONSTRUCTION BOARD OF ADJUSTMENT AND APPEALS.
(A) General. In order to hear and decide appeals of orders, decisions or determinations
made by the Building Official relative to the licensing and/or application and interpretation
FOR REFERERENCE ONLY, NOT UP FOR PLANNING COMMISSION VOTE
of this chapter, the Board of Zoning Appeals (BZA) shall be the designated board of officials
appointed by the governing body, as established in Section 153.047 of the Zoning and Land
Development Ordinance.re shall be and is hereby created a Construction Board of
Adjustment and Appeals. The Construction Board of Adjustment and Appeals shall be
appointed by the governing body and shall hold office at its pleasure. The Board shall adopt
rules of procedure for conducting its business.
(1) Decision-making authority. The Town of James Island The Charleston County Board
of Zoning AppealsConstruction Board of Adjustment and Appeals shall have final decision-
making authority on the following matters:
(a) Appeals of orders, decision or determination made by the Building Official.;
(b) Appeals of revocation of Llicensing or registration of building contractors;
(c) Adjustments and appeals for stormwater management utility fees; and
(d) Appeals and variances of flood plain management in reference to Chapter 151 of
the Code of Ordinances of the Town of James Island entitled “Town Regulations Concerning
Flood Damage Prevention”.
(ce) The Town of James Island Board of Zoning Appeals Charleston County
Construction Board of Adjustment and Appeals (“Board”) does not act in a review or
recommending capacity.
(2) Officers, rules, meetings and minutes. The composition of the Board, rules, meeting
and minutes shall be those set forth in Section 153.27 of the Zoning and Land Development
Regulations Ordinance. In cases of appeal, the Building Official shall serve as the Town’s
designee who shall provide a case number, a staff report documenting the facts of the case
and present that report and any other pertinent information to the Board. The Charleston
CountyTown of James Island Construction Board of Adjustments and Appeals shall elect
one of its members as Chairperson and another as Vice-Chairperson, both who shall serve
for one year or until re-election or a successor is elected and qualified. The Charleston
CountyTown of James Island Construction Board of Adjustment and Appeals shall adopt
rules and procedures in accordance with the provision of this chapter and shall keep a
record of its resolutions, findings and determinations, all of which, upon approval, shall be
filed immediately in the office of Building Official. Such records shall be available for public
review and inspection during normal business hours. The Building Official shall be a non-
voting member of the Board and shall serve as the Secretary. Meetings of the Board shall be
at the call of the Chairperson or at such other times as a majority of the Board may
determine. Public notice of all meetings of the Board shall be provided by at least electronic
deliver to the major news television stations, the major newspaper of general circulation,
the major radio communication companies, and several individual town/jurisdiction
papers. A quorum for the transaction of official business by the Board shall consist of six
members. The decision of the Board shall be final unless the petitioner appeals the decision
FOR REFERERENCE ONLY, NOT UP FOR PLANNING COMMISSION VOTE
to the circuit court in Charleston County within 30 days after the date of the decision of the
Board.
(B) Adjustments and appeals.
(1) The Board of Zoning Appeals Construction Board of Adjustment and Appeals shall
hear and decide requests for adjustment and appeals meeting all of the following
provisions:
(a) Decisions on which an adjustment or appeal is requested shall be those made by
the Building Official or his designee.
(b) The Board of Zoning Appeals Construction Board of Adjustment and Appeals is
authorized to hear requests for adjustment or appeal to this code and other codes,
regulations, or ordinances as specifically authorized in the Code of Ordinances, Town of
James Island, South Carolina. or determined by the Building Official to be within the scope
of the Construction Board of Adjustment and Appeals.
(2) Right to appeal. Appeals of administrative orders, decisions or determinations
causing the appeal or variance as required may be filed by the owner of the property
affected by the decision or his or her duly authorized representative, or by any person with
a substantial interest in a decision of the Building Official.
(3) Application filing; timing. Requests for a hearing for an adjustment or appeal of a
decision shall be in writing, and shall be received in the office of the Building Official within
20 calendar days of notice of the decision causing the filing of the adjustment or appeal.
The case will be added to the next regularly scheduled Board of Zoning Appeals meeting.
Proper notification requirements and timelines shall be met; if they are not able to be met
then the case will be scheduled for the next available scheduled meeting date.
(C) Decisions. The decisions of the Board of Zoning Appeals Construction Board of
Adjustment and Appeals shall be final unless the applicant appeals the decision to the
circuit court in Charleston County within 320 days after the date of the decision of the
Board of Zoning AppealsConstruction Board of Adjustment and Appeals.
(D) Limitations on authority. An application for appeal shall be based on a claim that the
true intent of this chapter or the rules legally adopted thereunder have been incorrectly
interpreted, the provisions of this chapter do not fully apply or an equally good or better
form of construction is proposed. The Board shall have no authority to waive requirements
of this chapter.
(E) Qualifications. The Construction Board of Adjustment and Appeals shall consist of
members who are qualified by experience and training to pass on matters pertaining to
building construction and are not employees of the jurisdiction
.
(F) Composition. The Charleston County Construction Board of Adjustment and Appeals
shall consist of eleven members appointed by Charleston County Council for a term of four
FOR REFERERENCE ONLY, NOT UP FOR PLANNING COMMISSION VOTE
years each. The term of office shall be staggered so no more than one-third of the Board is
appointed or replaced in any year. Members shall serve without compensation for the
county. Any vacancy which may occur on the Board shall be filled by County Council
appointing a successor to serve out the unexpired term of the vacancy. No member of the
Board may hold an elected public office in Charleston County. The eleven member Board
shall consist of the following:
(1) Two must be registered architects;
(2) One must be a registered structural engineer;
(3) One must be a registered mechanical engineer;
(4) Two must be registered civil engineers;
(5) One must be a licensed general contractor;
(6) One must be a mechanical contractor;
(7) One must be a licensed electrical contractor;
(8) One must be a licensed plumbing contractor; and
(9) One licensed residential home builder.
(G) Established; composition. The Construction Board of Adjustment and Appeals
appointed by County CouncilTown Council shall consist of 11 appointed members and the
Building Official shall be a non-voting member of the Board and shall serve as the
Secretary. All appointments shall be for a term of four years. The terms of office shall be
staggered so no more then one-third of the Board is appointed or replaced in any year.
Vacancies shall be filled for an unexpired term in the manner in which original
appointments are required to be made. Absence of a member in excess of three consecutive
meetings may render any such member liable to immediate removal from office.
(H) Quorum. Six members of the Board shall constitute a quorum.
(I) Establish rules for the carrying out responsibilities. The Construction Board of
Adjustment and Appeals shall establish rules, as appropriate, for carrying out these
assigned responsibilities.
(J) The decisions of the Construction Board of Adjustment and Appeals shall be final
unless the petitioner appeals the decision to the circuit court in Charleston County within
20 days after the date of the decision of the Construction Board of Adjustment and Appeals.
(K) Additional responsibilities.
(1) Licensing.
(a) Ground for revocation of town license. The Board may revoke the license or
registration of any building contractor who is found guilty of fraud or deceit in obtaining a
license, or gross negligence incompetence, or gross misconduct in conducting his business
FOR REFERERENCE ONLY, NOT UP FOR PLANNING COMMISSION VOTE
as a contractor. Any person who alleges gross negligence, incompetence, or gross
misconduct against any contractor licensed or registered hereunder shall submit such
allegation in affidavit form and file the same with the Secretary of the Board.
(ab) Reissuance of revoked license or registration. The Licensing Official or Building
Official may revoke a Town Contractor license. The Board may consider aappeals request
to reissue the Ttown licenses of any person whose license or registration has been revoked
six months after the date of revocation, if a majority of the members of the Board vote in
favor of such reissuance for reasons the Board deems sufficient. If the reissuance is denied,
the reissuance can be reconsidered at six-month intervals thereafter.
(c) Probation. The Board may place any building contractor on probation for a
specified period of time in lieu of reissuing a revokeding his or her Ttown license or
registration when allegations presented do not warrant revocation by the majority of the
Board for whatever reasons the Board deems sufficient.
(d) Hearing and decision of charges. Grounds detailed in division (K)(1)(a) above,
unless they are dismissed without hearing by the Board as unfounded or trivial, shall be
heard based on testimony under oath and a determination shall be made by the Board
within three months after the date of the hearing. The accused may cross examine
witnesses against him and produce evidence or witnesses in his or her defense. A written
record shall be made of the proceedings. If, after such hearing, the Board, by majority, votes
in favor of finding the accused guilty of any fraud or deceit in obtaining his license or
registration, or gross negligence, incompetence, or gross misconduct in conducting his
business as a contractor, his or her town license or registration will be revoked.
(2) Stormwater management. The Construction Board of Adjustment and Appeals shall
hear and decide requests for stormwater management utility adjustment and appeals as
follows:
(a) The Construction Board of Adjustment and Appeals shall hear the petition to
determine if the annual stormwater management utility fee does not apportion the fee with
approximate equality, based upon a reasonable basis of classification and with due regard
to the benefits conferred by providing stormwater management services to the utility
customer and the requirements of public health, safety or welfare. The determination of the
annual fee by the Construction Board of Adjustment and Appeals is entitled to presumption
of correctness and the applicant has the burden of rebutting the presumption of
correctness.
(b) The Construction Board of Adjustment and Appeals shall render a written
decision on each application that is heard, and such written decision shall be issued within
20 calendar days from the day the Board heard the application. The decision of the
Construction Board of Adjustment and Appeals shall contain findings of fact and
conclusions of law and the decision shall be sent to the petitioner by first class mail.
(c) Prior to bringing an action to contest an annual fee, the petitioner shall pay to the
treasurer not less than the amount of the annual stormwater fee which he admits in good
FOR REFERERENCE ONLY, NOT UP FOR PLANNING COMMISSION VOTE
faith owes. Payment of the fee shall not be deemed an admission that the annual fee was
due and shall not prejudice the applicant in bringing an action as provided herein.
(3) Flood plain management. The Construction Board of Adjustment and Appeals shall
hear and decide requests for appeals and variances as referenced in the current ordinance,
entitled “The Flood Damage Prevention and Protection.”
(Ord. 2016-14, passed 1-19-2017)
§ 150.15 VIOLATIONS.
(A) Violations.
(1) The violation of any of the codes or regulations adopted pursuant to the provisions
of this chapter is hereby declared to be a misdemeanor, and any person violating such
codes or regulations shall be deemed guilty of a misdemeanor and, upon conviction, shall
be punished in accordance with this section. In case of any violation of or proposed
violation of the codes or regulations adopted pursuant to this chapter, the Building Official
or other appropriate authority of the Town, or any adjacent or neighboring property owner
who would be damaged by such violation may, in addition to other remedies, apply for
injunctive relief, mandamus or other appropriate proceedings to prevent, correct or abate
such violation or threatened violation.
(2) Nothing in this chapter or in the codes adopted in this chapter shall be construed to
affect any suit or proceeding now pending in any court, or any rights acquired or liability
incurred, or any cause of action accrued or existing under any act or ordinance repealed
hereby, nor shall any right or remedy of any character be lost, impaired or affected by this
chapter.
(3) Each day any violation of this chapter or any such ordinance, resolution, rule,
regulation or order shall continue shall constitute, except where otherwise provided, a
separate offense.
(B) Service of complaint. Complaints by letter or orders hereunder shall be delivered to
and/or served upon such persons either personally or by registered mail (return receipt
requested), but if the whereabouts of such persons are unknown and cannot be ascertained
in the exercise of reasonable diligence, the Building Official or his designated
representative(s) shall make an affidavit to that effect, then the serving of such complaint
or order upon such persons may be made by publishing it once each week for two
consecutive weeks in a newspaper printed, and published, and in Charleston County and
circulating in the Town of James Island. A copy of such complaint or order shall be posted
in a conspicuous place on the premises affected by the complaint or order.
(C) Rights of persons affected by orders. Any person affected by an order issued by the
Building Official or his designated representative(s), may within 60 days after the posting
and service of the order, petition the circuit court for an injunction restraining the Building
FOR REFERERENCE ONLY, NOT UP FOR PLANNING COMMISSION VOTE
Official or his designated representative(s) from carrying out the provisions of the order,
and the court may, upon such petition, issue a temporary injunction restraining the
Building Official pending the final disposition of the cause. Hearings shall be had by the
court on such petitions within 20 days or as soon thereafter as possible and shall be given
preference over other matters on the court’s calendar as authorized by S.C. Code, § 31-15-
370, as amended. The court shall hear and determine the issues raised and shall enter such
final order or decree as law and justice may require. In all such proceedings, the findings of
the Building Official as to the facts, if supported by evidence, shall be conclusive. Costs shall
be at the discretion of the court. The remedies herein provided shall be exclusive remedies,
and no person affected by an order of the Building Official shall be entitled to recover any
damages for action taken pursuant to any order of the Building Official or his designated
representative(s) or because of compliance by such person with any order of the Building
Official.
(Ord. 2016-14, passed 1-19-2017)
§ 150.99 PENALTY.
Wherever in this chapter or in any ordinance of the Town any act is prohibited or is
declared to be unlawful or an offense or misdemeanor, or the doing of any act is required,
or the failure to do any act is declared to be unlawful or an offense or a misdemeanor, and
no specific penalty is provided for the violation thereof, the violation of any such provision
of this chapter, or any such ordinance, shall be subject to the maximum penalties
authorized for the Magistrates' Courts of the State of South Carolina, as from time to time
provided in S.C. Code, § 22-3-55, as amended, or successor legislation.
(Ord. 2016-14, passed 1-19-2017)
City of Charleston: BZA: 5pm
PC: 5pm
Charleston County: BZA: 5pm
PC: 2pm
Mt. Pleasant: BZA: 6pm
PC: 5pm
Summerville: BZA: 5pm
PC: 4pm
Ravenel: BZA: 6pm
PC: 6pm
Hollywood: BZA: 5pm
PC: 6:30pm
Folly Beach: BZA: 6pm
PC: 7pm
Awendaw: BZA: 6:30pm
PC: 6pm
Edisto Beach: BZA: 5pm
PC: work sessions 4pm; meetings 5pm
Source: Town of James Island website. First collected Oct 13, 2026.