Pacolet-Gateway-Sign-RFP-Packet
Town of Pacolet · Spartanburg County · meeting of Jul 17, 2024 · Agenda packets
Open the original document More from Town of Pacolet
Text
Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.
I. Introduction
The Town of Pacolet is requesting proposals for installation of a new gateway Welcome Sign at
the intersection of Hwy 176 and West Main Street. This will include landscaping as well as the
sign. The Encroachment Permit has been issued by SCDOT to proceed within their Right of
Way.
II. Overview:
This will be the 3rd sign of it’s type installed on Hwy 176 to welcome visitors in the Town of
Pacolet. The look, style and dimensions should be like the other two signs located at the
following intersections: Hwy 176 and Hwy 150; and Hwy 176 and Hwy 9.
III. Scope:
This Request for Proposals (RFP) is for a company or companies that can provide the monument
styled sign and the landscaping as described in the attached drawings. Included with this will
also be the removal of some of the trees located at this corner to allow for enough room to place
the entirety of the sign and landscape plan. The project includes electrical, masonry and
landscape work. All of this should be included in the proposal and cost. Please be aware of tree
removal area as well as the requirement for silt fencing.
IV. Questions and Addenda:
All questions and/or requests for clarification regarding this RFP should be provided in writing to
Patrick Kay, Town Administrator at pkay@townofpacolet.com no later than 4pm on August 2nd,
2024. All questions submitted and their answers will be posted on the Town of Pacolet website as
an addendum to this RFP. No telephone inquiries will be accepted.
If it becomes necessary to revise any part of this RFP, a written addendum will be issued. All
addenda issued by Town of Pacolet will become part of the official RFP and will be posted on the
Town of Pacolet website, www.townofpacolet.com . Receipt of all addenda must be
acknowledged in the proposal. The attached site plan should provide the contractor with all
relevant information to both provide proposal and cost sheet as well as installation of the project.
V. Proposal Contents:
Respondents interested in providing the services outlined in this RFP must prepare and submit a
proposal that includes the following, in the order listed:
a. Cover Letter:
The response should contain a cover letter signed by a person who is authorized to
commit the respondent to perform the work included in the proposal and should identify
all subcontractors, materials, and enclosures being forwarded in response to the RFP.
b. Project Schedule:
Provide a proposed project schedule that includes the key tasks, duration, and
deliverables that will complete the scope of work in this RFP. This should include a
proposed start date and days to complete the task.
c. Project Cost:
Provide a fixed price, total cost proposal for completing the scope of work outlined in this
RFP. The proposal should be itemized by work tasks and inclusive of all fees. Include
hourly fees that would be charged if additional work is added to the contract via change
order.
d. References:
Provide three (3) client references for relevant projects within the last 5 years that
indicate the past performances and abilities of the proposed team. Include a key client
contact person for each project with their current daytime phone number and email
address.
VI. Submittal Requirements:
One printed and one digital copy must be submitted to the Town of Pacolet by August 12th at 2:00
PM. Submit Quote Packet to:
Patrick Kay, Town Administrator
pkay@townofpacolet.com
ATTN: Gateway Sign
180 Montgomery Avenue
P O Box 700
Pacolet, SC 29372
VII. Deadline
The deadline for all submissions is August 12th, 2024, at 2:00 p.m. Town reserves the right to
extend the term of this RFP.
Filename:\\Ldg-1\f\Projects\21011\21011-00\Pdata\PWS-Existing Conditions and Demo.dwgPlot Time:5/8/2024 9:40:46 AM
SHEET TITLE:
SHEET
OF
DATE:REVISIONS:
DRAWN:
APPROVED:
JOB #:
This drawing is the property of The LandArt Design Group, Inc. and contains proprietary information furnished with the understanding that it is not to be modified, copied, reproduced or used by others except as required for this specific project without written authorization by The LandArt Design Group, Inc.
1.2.3.4.5.6.
PACOLET MONUMENT WELCOME SIGNHWY 176 & WEST MAIN STREET
PACOLET, SOUTH CAROLINA
EXISTING CONDITIONS
EXISTING CONDITIONS
21011-00
05/08/24
TP/EV/BB
TP
- -- -- -
L1L3
®
YOU ARE REQUIRED TO CALL AT LEAST3 WORKING DAYS BEFORE YOU DIG
http://www.call811.com/
Know what's below. Call before you dig.
SCALE:1" = 20'
1EXISTING CONDITIONS PLAN
L1
HERRING LAND SURVEYING105 GREENGATE LN.SPARTANBURG, SC. 29307Phone: (864) 384-2316
SCOTT HERRING, PLSherringlandsurveying@gmail.com
SURVEYOR
LOCATION MAP
SCALE:1" = 20'
2DEMOLITION PLAN
L1
EROSION CONTROL NOTES:
1.IF NECESSARY, SLOPES WHICH EXCEED EIGHT (8) VERTICAL FEET SHOULD BESTABILIZED WITH SYNTHETIC OR VEGETATIVE MATS, IN ADDITION TO HYDRO-SEEDING.IT MAY BE BE NECESSARY TO INSTALL TEMPORARY SLOPE DRAINS DURINGCONSTRUCTION. TEMPORARY BERMS MAY BE NEEDED UNTIL THE SLOPE IS BROUGHTTO GRADE.2.STABILIZATION MEASURES SHALL BE INITIATED AS SOON AS PRACTICABLE IN PORTIONSOF THE SITE WHERE CONSTRUCTION ACTIVITIES HAVE TEMPORARILY OR PERMANENTLYCEASED, BUT IN NO CASE MORE THAN FOURTEEN (14) DAYS AFTER WORK HASCEASED, UNLESS ACTIVITY IN THAT PORTION OF THE SITE WILL RESUME WITHINTWENTY-ONE (21) DAYS.3.ALL SEDIMENT AND EROSION CONTROL DEVICES SHALL BE INSPECTED EVERY SEVEN(7) DAYS OR AFTER EACH RAINFALL OCCURRENCE THAT EXCEEDS ONE-HALF (12) INCH. DAMAGED OR INEFFECTIVE DEVICES SHALL BE REPAIRED OR REPLACED, ASNECESSARY. INSPECTIONS SHOULD BE DOCUMENTED AND KEPT ON SITE FOR REVIEWBY SPARTANBURG COUNTY OR SCDHEC.4.PROVIDE SILT FENCE AND/OR OTHER CONTROL DEVICES, AS MAY BE REQUIRED, TOCONTROL SOIL EROSION DURING UTILITY CONSTRUCTION. ALL DISTURBED AREASSHALL BE CLEANED, GRADED AND STABILIZED WITH GRASSING IMMEDIATELY AFTERTHE UTILITY INSTALLATION.5.ALL EROSION CONTROL DEVICES SHALL BE PROPERLY MAINTAINED DURING ALLPHASES OF CONSTRUCTION UNTIL THE COMPLETION OF ALL CONSTRUCTIONACTIVITIES AND ALL DISTURBED AREAS HAVE BEEN STABILIZED. ADDITIONAL CONTROLDEVICES MAY BE REQUIRED DURING CONSTRUCTION IN ORDER TO CONTROLEROSION AND/OR OFFSITE SEDIMENTATION. ALL TEMPORARY CONTROL DEVICESSHALL BE REMOVED ONCE CONSTRUCTION IS COMPLETE AND THE SITE IS STABILIZED.6.THE CONTRACTOR SHALL DAILY REMOVE MUD/SOIL FROM PAVEMENT, AS MAY BEREQUIRED.7.RESIDENTIAL SUBDIVISIONS REQUIRE EROSIONS CONTROL FEATURES FORINFRASTRUCTURE AS WELL AS FOR INDIVIDUAL LOT CONSTRUCTION. INDIVIDUALPROPERTY OWNERS SHALL FOLLOW THESE PLANS DURING CONSTRUCTION ORPROVIDE AN INDIVIDUAL PLAN MEETING SECTION R.72-307 OF THE STORMWATERMANAGEMENT AND SEDIMENT REDUCTION ACT.8.TEMPORARY DIVERSION BERMS AND/OR DITCHES WILL BE PROVIDED AS NEEDEDDURING CONSTRUCTION TO PROTECT WORK AREAS FROM UPSLOPE RUNOFFAND/OR TO DIVERT SEDIMENT-LADEN WATER TO APPROPRIATE TRAPS OR STABLEOUTLETS.
DEMOLITION NOTES:
1.ALL MATERIAL GENERATED BY THE DEMOLITION WILL BE HAULED FROM THE SITE ANDDISPOSED OF PER LOCAL ORDINANCE.2.CONTRACTOR SHALL BE RESPONSIBLE FOR TRAFFIC CONTROL DURINGCONSTRUCTION PER WORK AREA TRAFFIC CONTROL HANDBOOK STANDARDS(W.A.T.C.H.).3.CONTRACTOR TO SUBMIT A SEQUENCING SCHEDULE FOR DEMOLITION.4.CONTRACTOR IS REPSONISBLE FOR COORDINATION OF DEMOLITION, RELOCATION,OR BURIAL WITH APPLICABLE UTILITY COMPANIES & SCDOT, I.E., GAS, CABLE,POWER, TELEPHONE, WATER, DRAINAGE, ETC.5.INSTALL ORANGE CONSTRUCTION FENCE AROUND PERIMETER OF AREAS BEINGDEMOLISHED AND AREAS UNDER CONSTRUCTION.
SEQUENCE OF CONSTRUCTION ACTIVITIES:
1.DETERMINE AND MARK LIMITS OF DISTURBANCE.2.HARVEST TIMBER3.PLACE PERIMETER SILT FENCE4.TOPSOIL REMOVAL AND/OR STORAGE.5.PLACE REMAINING SILT FENCES AS SHOWN ON PLANS.6.BEGIN MASS GRADING OPERATIONS.7.INSPECT AND MAINTAIN ALL EROSION CONTROL MEASURES EVERY 7 DAYS AND AFTER EACHSIGNIFICANT RAINFALL (0.5 INCHES OR GREATER) AND DOCUMENT WITH INSPECTIONREPORTS.8.PLACE TEMPORARY SEEDING ON ALL DISTURBED AREAS THAT WILL BE IDLE 14 DAYS ORLONGER.9.PERMANENT GRASS SHALL BE INSTALLED FOR ALL AREAS AT FINAL GRADE AND IN SEASON.FERTILIZE, WATER, AND RESEED AS REQUIRED TO ESTABLISH AND MAINTAIN A VIGOROUSSTAND OF GRASS.10.AFTER COMPLETION OF CONSTRUCTION AND THE SITE IS STABILIZED, (A) REMOVE ALLACCUMULATED SEDIMENT FROM SEDIMENT TRAPPING MEASURES AND SPREAD EVENLYACROSS THE SITE (B) REMOVE TEMPORARY EROSION CONTROL MEASURES, SMOOTH AREAAND APPLY APPROPRIATE GRASS.
0
SCALE:
feet 204060
1" = 20'
CONSTRUCTION NOTES:
1.INITIATE EROSION CONTROL SEQUENCE BEFORE BEGINNING CLEARING AND GRADING OPERATIONS.2.CLEAR AREAS TO BE GRADED OF ALL VEGETATION. PROTECT VEGETATION BEYOND CLEARING LIMITS.3.STRIP REMAINING TOPSOIL TO FULL DEPTH IN AREAS TO BE GRADED AND STOCKPILE. COMPACT ALL FILL AREAS TO 95% OF MAXIMUM DENSITY.4.ALL AREAS ARE TO BE GRADED SO THAT NO AREAS OF STANDING WATER OCCUR. PROPOSED SPOT ELEVATIONS ARE SHOWN AT FINISHED GRADE(BACK OF CURB ELEVATION, WHERE APPLICABLE).5.OPERATOR SHALL FIELD VERIFY EXISTING TOPOGRAPHY IN RELATION TO THE PROPOSED GRADES TO ENSURE DRAINAGE IN THE DIRECTIONS INDICATEDON THE PLAN.6.ALL MATERIALS AND CONSTRUCTION METHODS SHALL BE IN ACCORDANCE WITH SCDOT STANDARDS AND SPECIFICATIONS.7.THE SURVEY INDICATES NO PRESENCE OF 100-YEAR FLOOD ZONES WITHIN THE CONSTRUCTION LIMITIS OF THIS PROJECT SITE.8.ALL CALCULATIONS ARE BASED ON THE 10-YEAR STORM.9.ANY SEDIMENT SPILLED, DROPPED, WASHED OR TRACKED ONTO PUBLIC STREETS MUST BE REMOVED IMMEDIATELY.10.WHEN APPROPRIATE, WHEELS MUST BE CLEANED TO REMOVE SEDIMENT PRIOR TO ENTERING A PUBLIC STREET.11.CONTRACTOR SHALL STAKE SITE AS INDICATED ON CONSTRUCTION DOCUMENTS PRIOR TO COMMENCEMENT OF CONSTRUCTION. NOTIFY THELANDART DESIGN GROUP, INC. IMMEDIATELY OF ANY DISCREPANCIES.12.ALL DIMENSIONS ARE TO BACK OF CURB, FACE OF BUILDING OR CENTERLINE UNLESS OTHERWISE NOTED.13.ALL DETAILS SHALL BE CONSTRUCTED IN STRICT COMPLIANCE WITH SPECIFICATIONS AND CONSTRUCTION DOEUMENTS.14.CONSTRACTOR IS FULLY RESPONSIBLE FOR CONTACTING APPROPRIATE PARTIES AND ASSURING THAT EXSITING UTILITIES ARE LOCATED PRIOR TOBEGINNING CONSTRUCTION.15.CONTRACTOR IS RESPONSIBLE FOR PLACING BARRICADES, USING FLAG MEN, ETC, AS NECESSARY TO INSURE SAFETY TO THE PUBLIC.16.ALL PAVEMENT CUTS, CONCRETE OR ASPHALT, ARE TO BE REPLACED ACCORDING TO STANDARDS OF THE SOUTH CAROLINA DEPARTMENT OFTRANSPORTATION.17.ALL EARTHWORK MUST CONFORM TO LATEST SCDOT STANDARD SPECIFICATIONS FOR HIGHWAY CONSTRUCTION.
PROJECT INFORMATION
TOWN OF PACOLET180 MONTGOMERY AVE.PACOLET, SOUTH CAROLINA, 29372Phone: (864) 474-9504
PATRICK KAYpkay@townofpacolet.com
LANDART DESIGN GROUP, INC.647 EAST MAIN ST.SPARTANBURG, SC. 29302Phone: (864) 585-7500Fax: (864) 585-3808
TIPTON PITTS, ASLAtip@landartdesigngroup.com
KIPP KEMPERkipp@landartdesigngroup.com
LANDSCAPE ARCHITECT:
OWNER:
Sheet List TableSheet NumberSheet TitleL1EXISTING CONDITIONSL2LANDSCAPE PLANL3LIGHTING PLAN & DETAILS
No. 178
TheLandArtDesign Group,Inc.
CERTIFICATEOFAUTHORIZATION
SOUTHCAROLINA
TMAILLI
STTIP
W
. Caroln
uo
ai
ht
SfoetatSNo. 850REGISTEREDLANDSCAPEARCHITECT
F-101
D-101
REMOVE SIGNS DURINGCLEARING, & RE-INSTALLWHEN COMPLETED
DEMOLITIONSYMBOLDESCRIPTIONQTYDETAIL
TREE REMOVAL / CLEARING2,160 SF
FENCE SYMBOLDESCRIPTIONQTYDETAIL
SILT FENCING237 LF
D-101
F-101
REFERENCE NOTES SCHEDULE
S-42-10875' R/W(35 MPH)
810'-0"
SOUTH PINE ST
SC HWY 9 / US HWY 176R/W VARIES(55 MPH)
33
STREET SIGN
35
DOT SIGN
36
DOT SIGN
OHP
OHP
OHPOHP
759.00
759.00
758.00757.00
757.00
756.00
755.00
754.00753.00751.00749.00747.00
746.00
746.00
745.00
WHITESTRIPE
WHITESTRIPE
EDGEOFPAVEMENT
EDGEOFPAVEMENT
IPO 1" RB
24.79
58.42
33.01
755
754
753
752
751
S-42-10875' R/W(35 MPH)
SOUTH PINE ST
SC HWY 9 / US HWY 176R/W VARIES(55 MPH)
33
STREET SIGN
35
DOT SIGN
36
DOT SIGN
OHP
OHP
OHPOHP
759.00
759.00
758.00757.00
757.00
756.00
755.00
754.00753.00751.00749.00747.00
746.00
746.00
745.00
WHITESTRIPE
WHITESTRIPE
EDGEOFPAVEMENT
EDGEOFPAVEMENT
IPO 1" RB
810'-0"
Filename:\\Ldg-1\f\Projects\21011\21011-00\Pdata\PWS-Landscape and Layout Plan.dwgPlot Time:5/8/2024 9:40:47 AM
SHEET TITLE:
SHEET
OF
DATE:REVISIONS:
DRAWN:
APPROVED:
JOB #:
This drawing is the property of The LandArt Design Group, Inc. and contains proprietary information furnished with the understanding that it is not to be modified, copied, reproduced or used by others except as required for this specific project without written authorization by The LandArt Design Group, Inc.
1.2.3.4.5.6.
PACOLET MONUMENT WELCOME SIGNHWY 176 & WEST MAIN STREET
PACOLET, SOUTH CAROLINA
LANDSCAPE PLAN
LANDSCAPE PLAN
21011-00
05/08/24
TP/EV/BB
TP
- -- -- -
L2L3
NOTE:THE BASE INFORMATION FOR THIS DRAWING HAS BEEN COMPILEDFROM A VARIETY OF SOURCES AT VARIOUS TIMES AND AS SUCH ISINTENDED TO BE USED ONLY AS A CONCEPTUAL GUIDE. ALLPROPERTY LINES, TRACT DIMENSIONS AND DESCRIPTIONS ARE FORGRAPHIC PURPOSES ONLY, AS AN AID TO SITE LOCATION ANDPOSSIBLE POTENTIAL LAND USE. ANY PERSON DESIRING TODETERMINE ACTUAL COMMITMENTS SHOULD EXAMINE THEAPPROPRIATE PLATS, DEED RESTRICTIONS, COVENANTS, ANDPLANNING AND ZONING REGULATIONS APPLICABLE TO SPECIFICPORTIONS OF THE PROPERTY.
®
YOU ARE REQUIRED TO CALL AT LEAST3 WORKING DAYS BEFORE YOU DIG
http://www.call811.com/
Know what's below. Call before you dig.
SCALE:1" = 20'
1LAYOUT PLAN
L2
0
SCALE:
feet 102030
1" = 10'
SCALE:1" = 20'
2LANDSCAPE PLAN
L2
PLANTING NOTES:
1.MATERIALS LIST WAS PREPARED FOR ESTIMATING PURPOSES, CONTRACTORSHALL MAKE OWN QUANTITY TAKE-OFF USING DRAWINGS AND SPECIFICATIONSTO DETERMINE QUANTITIES TO HIS SATISFACTION, REPORTING PROMPTLY ANYDISCREPANCIES WHICH MAY EFFECT BIDDING.2.ROOT TYPES MAY BE FREELY SUBSTITUTED IN CASE OF BALLED AND BURLAPPEDOR CONTAINER GROWN. ALL PLANT MATERIAL MUST ADHERE TO ANSIZ60.1-2004 (AMERICAN STANDARD FOR NURSERY STOCK) SPECIFICATIONS FORROOT BALLS AND CONTAINER SIZES.3.CONTRACTOR TO VERIFY THAT ALL PLANT MATERIALS ARE AVAILABLE ASSPECIFIED WHEN BID/PROPOSAL IS SUBMITTED.4.UNLESS SPECIFICALLY NOTED, ALL PLANTS SHALL BE OF SPECIMEN QUALITY,EXCEPTIONALLY HEAVY, SYMMETRICAL, AND SO TRAINED OR FAVORED INDEVELOPMENT AND APPEARANCE AS TO BE UNQUESTIONABLY ANDOUTSTANDINGLY SUPERIOR IN FORM, COMPACTNESS AND SYMMETRY. THEYSHALL BE SOUND, HEALTHY, VIGOROUS, WELL BRANCHED AND DENSELYFOLIATED WHEN IN LEAF; FREE OF DISEASE AND INSECTS, EGGS OR LARVAE;AND SHALL HAVE HEALTHY, WELL-DEVELOPED ROOT SYSTEMS. THEY SHALL BEFREE FROM PHYSICAL DAMAGE OR OTHER CONDITIONS THAT WOULD PREVENTVIGOROUS GROWTH.5.SUBSTITUTIONS OF PLANT MATERIALS WILL NOT BE PERMITTED UNLESSAUTHORIZED IN WRITING BY THE LANDSCAPE ARCHITECT. IF PROOF IS SUBMITTED IN WRITING THAT A PLANT SPECIFIED IS NOT OBTAINABLE,CONSIDERATION WILL BE GIVEN TO THE NEAREST AVAILABLE SIZE OR SIMILARVARIETY, WITH A CORRESPONDING ADJUSTMENT OF THE CONTRACT PRICE.6.PLANTS SHALL CONFORM TO THE MEASUREMENTS SPECIFIED, EXCEPT TATPLANTS LARGER THAN THOSE SPECIFIED MAY BE USED IF APPROVED BY THELANDSCAPE ARCHITECT IN WRITING. USE OF LARGER PLANTS SHALL NOTINCREASE THE CONTRACT PRICE. IF LARGER PLANTS ARE APPROVED, THE ROOTBALL SHALL BE INCREASED IN PROPORTION TO THE SIZE OF THE PLANT.7.ROOT FLARE OF PLANT MATERIAL MUST BE AT OR SLIGHTLY HIGHER THANEXISTING GRADE. PULL MULCH BACK 6 IN. FROM ROOT FLARE.8.TREES WITH MULTIPLE LEADERS, UNLESS SPECIFIED, WILL BE REJECTED. TREESWITH A DAMAGED OR CROOKED LEADER, BARK ABRASIONS, SUNSCALD,DISFIGURING KNOTS, INSECT DAMAGE, CUTS OF LIMBS OVER 20 MM (34 IN.) IN DIAMETER THAT ARE NOT COMPLETELY CLOSED OR FLUSH PRUNING CUTS THATDO NOT PRESERVE THE COLLAR AT THE BRANCH WILL BE REJECTED.9.TREE PLANTING DETAILS AND SPECIAL PROVISIONS FOR PLANTING MUST BEFOLLOWED. DETAILS ARE PROVIDED ON THIS SHEET.10.CONTRACTOR SHALL TEST SOIL pH AND CONDITIONS FOR ALL SOD AREAS TOINSURE THAT PROPER SOIL REQUIREMENTS ARE MET FOR THE SODDED LAWN.SOIL SHALL BE AMENDED BY CONTRACTOR AS INDICATED BY SOIL TEST ANDSPECIFICATIONS TO ACHIEVE PROPER SOIL CONDITIONS.11.ALL PLANT BEDS TO RECEIVE 3" DEEP HARDWOOD MULCH, PULLED 6" AWAYFROM THE TRUNK.12.CONTRACTOR TO MAINTAIN THE PLANTINGS AND CONTROL WEEDS IN MULCHAREAS THROUGH THE DURATION OF CONSTRUCTION UNTIL FINALACCEPTANCE.13.ALL PLANT BED AND SOD AREAS TO RECEIVE 100% IRRIGATION COVERAGE .14.IN THE PLANT SCHEDULE, PLANTS NOTED AS "SPECIMEN", SHALL BE SELECTED BYTHE LANDSCAPE ARCHITECT AT THE NURSERY OR PHOTOS OF THE PLANTINGSTOCK SHALL BE SUBMITTED TO THE LANDSCAPE ARCHITECT FOR APPROVAL.15.PREEMERGENT HERBICIDE SHALL BE APPLIED TO PLANTING AREAS PRIOR TOLANDSCAPE INSTALLATION AND ACCORDING TO MANUFACTURER'SINSTRUCTIONS.16.PLANT BED SHALL BE TESTED FOR pH AND AMENDED PRIOR TO INSTALLATION.17.ALL PLANT MATERIAL SHALL CONFORM TO STANDARD SET FORTH BY"AMERICAN STANDARDS FOR NURSERY STOCK" ANSI Z60.1-2004 PUBLISHED BYTHE AMERICAN NURSERY AND LANDSCAPE ASSOCIATION.18.ALL PLANT MATERIAL SHALL BE PROTECTED DURING TRANSPORT AND DELIVERYTO JOB SITE WITH SHADE CLOTH OR OTHER ACCEPTABLE MEANS OF WINDBURNPREVENTION.19.ANY SUBSTITUTIONS IN SIZE AND/OR PLANT MATERIAL MUST BE APPROVED BYTHE LANDSCAPE ARCHITECT BEFORE PLANTING CAN BEGIN. 20.ALL TREES MUST BE STRAIGHT TRUNK, FULL HEADED, AND MEET ALLREQUIREMENTS SPECIFIED.21.PRIOR TO CONSTRUCTION, THE CONTRACTOR IS RESPONSIBLE FOR LOCATINGALL UNDERGROUND UTILITIES AND SHALL AVOID DAMAGE TO ALL UTILITIESDURING CONSTRUCTION. SHOULD THE CONTRACTOR CAUSE DAMAGE TOANY UTILITIES, NECESSARY REPAIRS SHALL BE MADE AS QUICKLY ASPRACTICABLE, AT CONTRACTOR'S EXPENSE.22.ALL ELEMENTS OF LANDSCAPING SHALL BE INSTALLED SO AS TO MEET ALLAPPLICABLE ORDINANCES AND CODES REQUIREMENTS.23.CONTRACTOR SHALL ASSURE DRAINAGE AND PERCOLATION OF PLANTING PITSPRIOR TO INSTALLATION OF PLANT MATERIAL. CONTRACTOR IS RESPONSIBLEFOR THE REPLACEMENT OF ALL PLANTS LOST DUE TO INADEQUATE DRAINAGECONDITIONS.24.BALLED AND BURLAP MATERIAL SHALL HAVE THE TOP ONE HALF (1/2) OF THEBURLAP AND STRAPS REMOVED.25.CONTRACTORS SHALL REFER TO THE LANDSCAPE PLANTING DETAILS, PLANTSLISTS, GENERAL NOTES AND THE PLANTING SPECIFICATIONS FOR COMPLETELANDSCAPE PLANTING INSTRUCTIONS.26.TURF GRASS SHALL BE PLANTED AFTER ALL PLANTS ARE INSTALLED ANDMULCHED. SEED AND/OR SOD BED PREPARATIONS BY MEANS OFPULVERIZATION TO LOOSEN SOIL. SMOOTH AND FINE GRADE AREA REMOVINGANY ROCKS, ROOTS, TRASH, AND CLODS OVER ENTIRE AREA.27.THE CONTRACTOR IS RESPONSIBLE FOR MAINTAINING IN FULL ALL PLANTINGAREAS (INCLUDING WATERING, SPRAYING, MULCHING, MOWING, FERTILIZING,ETC.) UNTIL THE OWNER AND LANDSCAPE ARCHITECT ACCEPT CONSTRUCTIONIN FULL AT THE END FOR THE ESTABLISHED PERIOD.28.CONTRACTOR TO GUARANTEE PLANT MATERIAL FOR 12 MONTHSESTABLISHMENT PERIOD FOLLOWING DATE OF COMPLETED CONSTRUCTION.
GENERAL NOTES:
1.THE CITY WILL FURNISH, INSTALL AND MAINTAIN ALL PLANTINGS. SCDOT SHALL NOT BE RESPONSIBLE FOR PROVIDING WATER,FERTILIZER, LABOR, MATERIALS, OR MAINTENANCE WITHIN THE LANDSCAPING LIMITS OF THE RIGHT OF WAY.2.ALL LANDSCAPING WORK WITHIN THE SCDOT RIGHT-OF-WAY SHALL CONFORM TO ALL LOCAL ORDINANCES AND ALL STATEENVIRONMENTAL REGULATIONS.3.CONTRACTOR SHALL PERFORM INSTALLATION UNDER THE SUPERVISION OF THE SCDOT, AND SHALL NOT BLOCK TRAFFIC AT ANYTIME. ALL TRAFFIC CONTROL DEVICES SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR AND SHALL CONFORM TO SECTION VOF THE MUTCD.4.CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVING AND DISPOSAL OF EXISTING PLANT MATERIAL WITHIN THE NEW BULB OUTPLANTING AREAS.5.CONTRACTOR SHALL DAILY REMOVE MUD / SOIL FROM ALL PAVEMENTS, AS MAY BE REQUIRED.6.PRIOR TO CONSTRUCTION, THE CONTRACTOR IS RESPONSIBLE FOR LOCATING ALL UTILITIES, AND SHALL AVOID DAMAGE TO ALLUTILITIES DURING CONSTRUCTION. SHOULD THE CONTRACTOR CAUSE DAMAGE TO ANY UTILITIES, NECESSARY REPAIRS SHALL BEMADE AS QUICKLY AS PRACTICABLE, AT THE CONTRACTORS EXPENSE.7.CONTRACTOR TO REMOVE & DISPOSE OF EXISTING PLANTS IN THE PROPOSED NEW PLANTINGS, INCLUDING REMOVAL OF ANYTREE STUMPS.8.ALL SIGN LOCATIONS ARE TO BE MEASURED FROM THE WORK AREA. WORK AREA LIMITS FOR THE PROJECT WILL BE DETERMINEDBY THE ENGINEER AND AS INDICATED IN THE CONTRACT.9.ALL PERMANENT CONSTRUCTION SIGNS ARE TO BE GROUND MOUNTED 2 FEET FROM THE EDGE OF A PAVED SHOULDER OR THEFACE OF A CURB OR 6-12 FEET FROM THE EDGE OF AN ADJACENT TRAVEL LANE WHERE NO PAVED SHOULDER EXISTS TO THENEAREST EDGE OF THE SIGN. ALSO, MOUNT EACH PERMANENT CONSTRUCTION SIGN SO THE BOTTOM EDGE OF THE SIGN SHALLHAVE A MINIMUM MOUNTING HEIGHT OF NO LESS THAN 7 FEET ABOVE THE ELEVATION OF THE ADJACENT TRAVEL LANE.HOWEVER, IF SECONDARY SIGN IS MOUNTED BELOW THE MAJOR SIGN, THE BOTTOM EDGE OF THE SECONDARY SIGN SHALL BENO LESS THAN 6 FEET ABOVE THE ELEVATION OF THE TRAVEL LANE. SPECIAL SIGN MOUNTING ASSEMBLIES MAY BE NECESSARY INAREAS OF DOUBLE-FACED GUARDRAIL, CONCRETE MEDIAN BARRIER AND/OR BRIDGE PARAPET WALLS AND SHALL BE PROVIDEDBY THE CONTRACTOR.10.MOUNT FLAT SHEET SIGNS SUCH THAT THEY ARE STRAIGHT AND LEVEL AND THE FACE OF THE SIGNS ARE PERPENDICULAR TO THESURFACE OF THE ROADWAY.11.REFLECTORIZE ALL ORANGE PERMANENT CONSTRUCTION SIGNS AND ANY ORANGE AREAS OF A MULTICOLORED PERMANENTCONSTRUCTION SIGN WITH A FLUORESCENT ORANGE COLORED PRISMATIC REFLECTIVE SHEETING WHERE THE SIGNS ARE TO BEORANGE. ALSO, REFLECTORIZE ALL WHITE PERMANENT CONSTRUCTION SIGNS AND ANY WHITE AREAS OF A MULTICOLOREDPERMANENT CONSTRUCTION SIGN WITH A WHITE COLORED PRISMATIC REFLECTIVE SHEETING WHERE THE SIGNS ARE TO BE WHITE.12.SPACINGS INDICATED ARE FOR NORMAL CONDITIONS; ADJUSTMENTS MAY BE REQUIRED DUE TO HORIZONTAL AND/ORVERTICAL ALIGNMENTS OR OTHER SIGHT DISTANCE RESTRICTIONS.13.THE DEPARTMENT RESERVED THE RIGHT TO RESTRICT CONSTRUCTION OPERATIONS AND/OR WITHHOLD THE MONTHLY ESTIMATES IFTHE PERMANENT CONSTRUCTION SIGNS ARE NOT PROPERLY INSTALLED AND MAINTAINED IN ACCORDANCE WITH THE STANDARDSPECIFICATIONS, THE SPECIAL PROVISIONS, THE STANDARD DRAWINGS, THE PLANS AND/OR THE ENGINEER.14.ALL TRAFFIC CONTROL DEVICES, INCLUDING PORTABLE SIGN SUPPORTS, SIGN SUBSTRATUMS, AND BREAKAWAY SYSTEMS FORGROUND MOUNTED SIGN SUPPORTS, SHALL COMPLY WITH ALL NCHRP REPORT 350 REQUIREMENTS AND SHALL BE APPROVED BYTHE DEPARTMENT. ALL APPROVED TRAFFIC CONTROL DEVICES SHALL BE INCLUDED ON THE "APPROVED PRODUCTS LIST FORTRAFFIC CONTROL DEVICES IN WORK ZONES". THIS LIST MAY BE ACCESSED ON THE DEPARTMENT'S WEBSITE AT: www.scdot.org .15.PERMANENT CONSTRUCTION SIGNS WITH THE "ROAD WORK" LEGEND IS REQUIRED ON ALL PROJECTS LET TO CONTRACT AFTEROCTOBER 1, 20033. SIGNS WITH THE "ROAD CONSTRUCTION" LEGEND CONTINUE TO BE ACCEPTABLE ON PROJECT LET TOCONTRACT PRIOR TO OCTOBER 1, 2003. ON PROJECTS LET PRIOR TO OCTOBER 1, 2003, INTERMINGLING OF SIGNS WITH "ROADWORK" AND "ROAD CONSTRUCTION" IS PROHIBITED.16.TEMPORARY SIGNAGE MUST ALSO BE USED WHILE WORKMEN ARE PRESENT.
MONUMENT SIGN2L3
CODEQTYBOTANICAL / COMMON NAMECONTCAL
TREESCHI CHS3CHIONANTHUS RETUSUS `CHINA SNOW` / CHINA SNOW CHINESE FRINGE TREEB & B2.5"CAL JUN TOR3JUNIPERUS CHINENSIS `TORULOSA` / HOLLYWOOD JUNIPER15 GAL
CODEQTYBOTANICAL / COMMON NAMECONTSIZE
SHRUBSCRY GLO2CRYPTOMERIA JAPONICA 'GLOBOSA NANA' / DWARF JAPANESE CEDAR3 GAL ROS PED7ROSA MEIDILAND SERIES `PEACH DRIFT` / PEACH DRIFT ROSE3 GAL YUC COG6YUCCA FILAMENTOSA `COLOR GUARD` / COLOR GUARD YUCCA3 GAL
PLANT SCHEDULE
B & B - 3CHI CHS
15 gal - 3JUN TOR
3 gal - 7ROS PED
3 gal - 6YUC COG
3 gal - 2CRY GLO
SCDOT SIGHT TRIANGLEISD = 810'SCDOT SIGHT TRIANGLEISD = 810'
33
STREET SIGN
3536
OHP
OHP
OHP
OHP
OHP
OHP
OHP
755.00
754.00753.00751.00749.00747.00 WHIT
EDGEOFPAVEMENT
COMPACTED SUBGRADE
#4 TRANSVERSE REBAR @ 18" O.C.
#4 REBAR CONTINUOUS @ 18" O.C.
4000 PSI CONCRETE FOOTER
MASONRY TIES EVERY THIRDCOURSE OR AS NEEDED (TYP.)
8"X12"X12" C.M.U., BASEFILLED SOLID WITH GROUT (TYP.)
#4 REBAR
STONE, 3" THICK; TO MATCH EXISTING MONUMENTMORTAR TO TOP OF COLUMN
A
CHISELED CUT STONE CAP
1'-8"1'-6"
412"5'-2"
7'-0"
3'-0"
12'-0"
#4 REBAR CONTINUOUS @ 18" O.C.4000 PSI CONCRETE FOOTER
SECTION A
8"X12"X12" C.M.U., BASEFILLED SOLID WITH GROUT (TYP.)
#4 REBAR
STONE, 3" THICK;TO MATCH EXISTING MONUMENT
CHISELED CUT STONE CAP
FOOTING OUTLINE
1'-8"1'-6"
1'-8"1'-6"
7'-0"
Filename:\\Ldg-1\f\Projects\21011\21011-00\Pdata\PWS-Lighting Plan and Details.dwgPlot Time:5/8/2024 9:40:51 AM
SHEET TITLE:
SHEET
OF
DATE:REVISIONS:
DRAWN:
APPROVED:
JOB #:
This drawing is the property of The LandArt Design Group, Inc. and contains proprietary information furnished with the understanding that it is not to be modified, copied, reproduced or used by others except as required for this specific project without written authorization by The LandArt Design Group, Inc.
1.2.3.4.5.6.
PACOLET MONUMENT WELCOME SIGNHWY 176 & WEST MAIN STREET
PACOLET, SOUTH CAROLINA
LIGHTING PLAN & DETAILS
LIGHTING PLAN &DETAILS
21011-00
05/08/24
TP/EV/BB
TP
- -- -- -
L3L3
0
SCALE:
feet 102030
1" = 10'
NOTE:THE BASE INFORMATION FOR THIS DRAWING HAS BEEN COMPILEDFROM A VARIETY OF SOURCES AT VARIOUS TIMES AND AS SUCH ISINTENDED TO BE USED ONLY AS A CONCEPTUAL GUIDE. ALLPROPERTY LINES, TRACT DIMENSIONS AND DESCRIPTIONS ARE FORGRAPHIC PURPOSES ONLY, AS AN AID TO SITE LOCATION ANDPOSSIBLE POTENTIAL LAND USE. ANY PERSON DESIRING TODETERMINE ACTUAL COMMITMENTS SHOULD EXAMINE THEAPPROPRIATE PLATS, DEED RESTRICTIONS, COVENANTS, ANDPLANNING AND ZONING REGULATIONS APPLICABLE TO SPECIFICPORTIONS OF THE PROPERTY.
®
YOU ARE REQUIRED TO CALL AT LEAST3 WORKING DAYS BEFORE YOU DIG
http://www.call811.com/
Know what's below. Call before you dig.
SCALE:1" = 10'
1LIGHTING PLAN
L3
GENERAL LIGHTING NOTES:1. THIS PLAN IS INTENDED FOR LANDSCAPE LIGHTING PURPOSES ONLY. ALL LIGHTING FIXTURES AND TRANSFORMERS SHALL BEINSTALLED PER MANUFACTURERS SPECIFICATIONS. IT IS THE CONTRACTORS RESPONSIBILITY TO MAINTAIN COMPLIANCE WITH ALL LOCALBUILDING SAFETY CODES AND ORDINANCES.2. FIXTURES ARE SHOWN IN APPROXIMATE LOCATION. THE CONTRACTOR SHOW FIELD VERIFY THE ACTUAL PLACEMENT OF EACH FIXTUREUPON COMPLETION OF LANDSCAPE INSTALLATION.3. ALL PATH LIGHTS ARE TO BE INSTALLED AT A MINIMUM OF 12 INCHES FROM ANY SIDEWALK OR VERTICAL STRUCTURE.4. ALL LOW-VOLTAGE DIRECT BURIAL WIRE TO BE INSTALLED AT >/= 6" BELOW FINISH GRADE PER ELECTRICAL CODE.5. IN ORDER TO MINIMIZE FUTURE DISTURBANCE, ALL WIRE RUNS SHALL BE INSTALLED PARALLEL AND ADJACENT TO HARD SURFACESSUCH AS SIDEWALKS DRIVEWAYS AND WALLS.6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING SLEEVES UNDER ALL HARDSCAPE SURFACES USING A MINIMUM 1 INCH PVCPIPE.7. ALL UNDERGROUND SPLICES SHALL BE UL-486RATED AND INSTALLED IN UNDERGROUND J-BOXES WITH WATER TIGHT CONNECTIONSLEAVING 12 INCHES OF EXCESS WIRE SLACK.8. ALL EXTERIOR 120 - VOLT ELECTRICAL OUTLETS SHALL BE GFI PROTECTED AS PER NATIONALELECTRICAL CODE.9. ALL TRANSFORMERS PLUGGED INTO AN OUTDOOR RECEPTACLE SHALL HAVE AN "IN USE" COVER. CONTRACTOR SHALL INSTALLTAYMAC TYPE COVERS AT ALL OUTLETS.10. ALL PLUG-IN TRANSFORMERS SHALL HAVE A DRIP LOOP IN THE POWER CORD.11. ALL EXPOSED CONDUIT'S SHALL BE PAINTED TO MATCH SURROUNDINGS.12. THE INSTALLING CONTRACTOR SHALL BE RESPONSIBLE FOR ADJUSTING THE FIXTURES AT NIGHT TO HELP ELIMINATE GLARE AND TOENSURE OPTIMUM LIGHTING EFFECT.13. CONTRACTOR TO VERIFY A MINIMUM OF 11 VOLTS FOR ZDC AT THE LAST AT THE LAST FIXTURE FOR OPTIMAL OPERATION.14. CONTRACTOR TO CENTER FEED THE SYSTEM WHEN AT ALL POSSIBLE and VERIFY ALL WIRE CONNECTIONS ARE AT THE FIXTURES.15.ALL WIRE CONNECTIONS AT FIXTURES SHALL BE MADE USING WATER TIGHT CONNECTIONS.
SYMBOLMANUFACTURER/MODEL/DESCRIPTIONQTYDETAIL
STERLING LIGHTING SL24 FLOOD LIGHT2
STERLING LIGHTING SLO6 WELL LIGHT6
STERLING LIGHTING TRANSFORMER 300 W1 WITH PHOTO CELL
SYMBOLMANUFACTURER/MODEL/DESCRIPTIONQTYDETAIL
NEW ELEC. PANEL / METER BASE1
QUAD OUTDOOR OUTLET1
LIGHTING SCHEDULE
SCALE:1/2" = 1'
2WELCOME SIGN ELEVATION
L3SCALE:1/2" = 1'
6FOOTING DETAIL
L3
SCALE:1/2" = 1'
5WELCOME SIGN SECTION
L3
SCALE:1/2" = 1'
4WELCOME SIGN SECTION PLAN
L3
SCALE:1/2" = 1'
3WELCOME SIGN PLAN
L3
7.2W15V
7.2W15V
1 21W300W
MOUNTING EXAMPLE FOR POWER METER, OUTLET, AND BREAKER BOX.
WELCOME SIGN MATERIALS AND DIMENSIONS.
Source: Town of Pacolet website. First collected Oct 13, 2026.