TRC Minutes 08.27.26 Page 1 of 5
TECHNICAL REVIEW COMMITTEE MINUTES
Thursday, August 27, 2026 – 10:00 A.M.
Training Room/Zoom
NEW APPLICATIONS
CR-26-42: Courtesy Review – Gas Station at 870 Highway 17 South
Attending
Customer
Representatives:
Ryan Goff, James Farrelley & Mellissa Norman
Staff Comments
Public Works: 1. Provide current survey and wetland delineation/determination.
2. Water and sewer available
3. Add a SCDES approved backflow on water service and fire/ irrigation lines.
4. Provide traffic impact analysis.
5. Entrance radii on 9th S. & Hwy. 17 crosses the property lines.
6. SCDOT permits for all work in rights-of-way. Right turn lane may be required
on 9th Ave S.
7. Signalized intersection may be required. Coordinate with SCDOT. Significant
improvements to 9th Ave S may be required.
8. Sign appears to be in the site triangle. See SCDOT standards for site triangle
dimensions.
9. Relocate the fuel tanks away from the existing water line along Hwy 17 right-of-
way. GIS shows an 8” water main only 2’ inside the Hwy 17 right-of-way (+/- 12’
to fuel tanks current location).
10. Front load dumpsters will require a private hauler.
11. There is drainage that passes through this site that will need to be accounted for.
Perimeter drainage needs to be addressed.
12. Must meet city storm water design standards.
13. Impact fees to be calculated based on water usage of a similar sized store.
14. Applicant to provide copies of water bills from a similar sized store for
evaluation. Applicant will be required to execute a Water and Sewer Fee 24-
month agreement.
15. Additional comments reserved.
Zoning: 16. Screening needed between incompatible uses. A finished six-foot high solid
masonry wall on the rear property line.
17. Landscaping plan needed.
18. Lighting plan needed. Shield all fixtures from residential properties. Ligh shall
not exceed .5 fc at the residential property line in the rear.
19. Move proposed sign out of 20' x 29' sight triangle.
20. Additional comments may be generated.
Building: No comments
Fire: 21. All portions of the building must be within required fire access distance. Revise
the plan to demonstrate compliance.
TRC Minutes 08.27.26 Page 2 of 5
22. Provide a fire apparatus turning exhibit to confirm that emergency vehicles can
access all areas of the site.
23. Fire hydrants shall be spaced in accordance with City standards (maximum
spacing measured along the roadway). Provide a dimensioned exhibit
demonstrating compliance.
Planning: 24. The requirement for cross-access has been waived by the Planning &
Development Director due to site-specific constraints. No cross-access
connection is required for this project.
25. Extend the public sidewalk to 9th Ave S.
26. Provide a continuous, accessible pedestrian connection between the public
sidewalk and the primary building entrance. Revise the site plan to clearly show
the route and associated improvements.
SUB-26-36: Major Preliminary Subdivision – Five Residential Lots, Common Area, and Private Right-of-Way off West
Pelican Road called Long Bay Marina
Attending
Customer
Representatives:
Mary Kramer, Engineer
Staff Comments
Public Works: 1. Add check dams or sediment tubes to erosion control plans for the ditch that
extends to the waterway.
2. Show EC matting on the steep slopes on waterway grading. Provide ECM detail.
3. Address the above prior to printing construction sets for sigh-off.
Zoning: No comments
Building: No comments
Fire: No comments
Planning: 4. This item will require Planning Commission review prior to approval.
5. Please provide the letter from NALT approving the construction plans.
TRC-26-23: Site Specific Development Plan –Compass Resort at 1025 Highway 17 South
Attending
Customer
Representatives:
Cameron Parker, Engineer
Staff Comments
Public Works: Comments pending second review.
Zoning: 1. 6 HC spaces needed total.
2. How many compact parking spaces are proposed in total? 10% od required
minimum spaces. Any surplus spaces may be compact.
3. Please label drive aisle width on all parking lots. Lot 1 appears to fall short of
the 22' drive aisle width in some areas.
4. Label parking lot interior landscape percentage on all the parking lots.
5. Provide landscaping plan.
6. Provide lighting plan.
7. Shield all fixtures from residential property.
8. .5 maximum FC at residential property lines.
9. Parking lot 2. What angles are these parking spaces?
TRC Minutes 08.27.26 Page 3 of 5
10. Lot 2. Label one way traffic pattern and paint arrows, provide "do not enter"
sign.
11. Lot 2. Provide curbing to protect landscaping. Trees less than 24" are not
required to be saved. Any existing natural landscape character shall be
preserved whenever possible, but curbing is required to protect landscaping.
Lot 2 appears to have no curbing.
12. All parking needs to be within 300 ft of the principal site. Lot 3 has 15 parking
spaces that are either greater than 300 feet away or the drive aisle to access them
is over 300 feet away. Possible moving of dumpster/compactor to rear of lot
13. would allow for two additional parking spaces.
14. Show proposed dumpster/compactor.
15. Show the parking spaces on site, only counting 17.
16. 182 spaces remain as of now.
17. Provide parking requirement on front page, show the number of rooms and
bedroom count.
Building: 18. Handicap parking requirements (6 spots).
Fire: No comments
Planning: No comments
TRC-26-25: Site Specific Development Plan – Drift Eatery at 1023 Highway 17 South
Attending
Customer
Representatives:
James Baldwin, Engineer
Staff Comments
Public Works: 1. SCDOT encroachment permit for work in the Hwy R/W. SCDOT must review
and approve the new point discharge to US Hwy 17 right-of-way.
2. Provide percentage of of redevelopment area vs existing developed conditions.
3. Per the city’s storm water design manual, Sec 1.2:2.
4. If the redevelopment project does not have an existing stormwater conveyance
system, no detention or retention, or no water quality treatment, then perform
the following:
A. If the redevelopment project area is less than fifty (50) percent of the
existing developed condition area and includes the addition of
impervious area, then all standards of the SWDM apply to the
additional impervious area.
B. If the redevelopment project area equals or exceeds fifty (50) percent of
the existing developed condition area, then all standards of the SWDM
apply for the entire redevelopment project area. Pre-development
conditions shall be evaluated as open grass for the onsite soil type(s) for
the project site.
5. Additional comments reserved.
Zoning: No comments
Building: No comments
Fire: 6. Piping to meet standards (See City of North Myrtle Beach Public Utilities
Guidebook)
7. Fittings to meet standards (See City of North Myrtle Beach Public Utilities
Guidebook)
TRC Minutes 08.27.26 Page 4 of 5
8. Bituminous coating applied (NFPA 24)
9. 36 in. Burial depth (NFPA 24)
10. Trace wire for CPVC piping
11. Visual inspection before covering
12. Proper thrust blocking (See City of North Myrtle Beach Public Utilities
Guidebook)
13. Hydro test 200 psi/2hrs (NFPA 24)
14. Flush pipe (NFPA 24)
15. NFPA 24 certificate (NFPA 24)
16. Show details for all piping including fire department connections
17. A permit is required by the utility contractor for underground fire lines.
18. If you put the BFP in the building the vault is not required.
19. Fire hydrants shall be spaced in accordance with City standards (maximum
spacing measured along the roadway). Provide a dimensioned exhibit
20. demonstrating compliance. Needs a hydrant within 150 of FDC
21. FDC to be 5-inch stortz connection.
22. Based on the proposed occupancy/load, additional fire protection systems (e.g.,
sprinklers, fire alarm) may be required. Revise plans to demonstrate compliance
with applicable code provisions.
Planning: No comments
CR-26-43: Courtesy Review – Obtaining Access to 27th Avenue North at 2607 Little River Neck Road
Attending
Customer
Representatives:
No attending representative
Staff Comments
Public Works: 1. This section of 27th Ave N is maintained by SCDOT (S-1232).
Zoning: No comments
Building: No comments
Fire: No comments
Planning: 2. City needs to convert parcel to public ROW; this will require a major final plat
with approval by Planning Commission.
CR-26-44: Courtesy Review – Discussion for Unopened Right-of-Way at the Intersection of Harbor Point Drive and
Village Crossing Boulevard
Attending
Customer
Representatives:
No attending representative
Staff Comments
Public Works: 1. Comments pending.
Zoning: Minor amendment needed.
Building: No comments
Fire: No comments
Planning: 2. I am not sure why ROW was created in a development but not constructed.
Should the city consider closing the public ROW and allow the neighborhood
to create the ROW whenever they want to move forward with the construction?
TRC Minutes 08.27.26 Page 5 of 5
BLD-26-4018: Building Permit – Medical Office on Second Floor at 1639 Highway 17 South
Attending
Customer
Representatives:
No attending representative
Staff Comments
Public Works: No comments
Zoning: No comments
Building: No comments
Fire: No comments
Planning: No comments