RecordWell Data

_07022026-562

City of North Myrtle Beach · Horry County · meeting of Jul 2, 2026 · Minutes

Open the original document More from City of North Myrtle Beach

Text

Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.

TRC Minutes 07.02.26 Page 1 of 3 TECHNICAL REVIEW COMMITTEE MINUTES Thursday, July 2, 2026 – 10:00 A.M. Training Room/Zoom NEW APPLICATIONS CR-26-32: Courtesy Review – Quick Service Restaurant at 1350 Highway 17 South Attending Customer Representatives: Robin Roberts, Applicant Staff Comments Public Works: 1. Confirm all drive aisles are minimum of 22 feet wide for 90-degree parking stalls. 2. Confirm cross access location matches existing cross access at Krispy Kreme. 3. One-way traffic is shown at the entrances, but two-way traffic arrows are shown internally. May be confusing to drivers, causing wrong way exits, etc. Recommend two full access driveways subject to SCDOT review/approval. 4. Provide a fire apparatus turning exhibit to confirm that emergency vehicles can access all areas of the site. 5. All proposed work within the Hwy. 17 right-of-way will require SCDOT encroachment permit(s). 6. Provide dimensions for key site elements including drive aisles, setbacks, and access points. 7. Show proposed grease trap location(s) on design plans. 8. Provide location and sizing for required SCDES approved backflow prevention devices (DCVA) on both domestic and irrigation services on design plans. 9. Provide a stormwater analysis demonstrating that the proposed system meets current City standards and accommodates the 25 year, 24-hour storm event. The pre-existing site condition is an open grassed field for the underlying soil condition. See storm water design documents on the City website under Public Works/ Engineering. 10. Front load dumpster is shown, will require a private hauler. City service is available, but would require side load dumpster(s). 11. Verify the size, location, and adequacy of all existing water and sewer services. Provide documentation and revise plans as needed to reflect accurate conditions. 12. Additional comments may be forthcoming pending further review or receipt of revised documents. Zoning: 13. Show parking space dimensions. 14. Label drive aisle width. 15. Cross access points reduce the parking requirement by 3 spaces. 16. 10% of parking area shall be green space. 17. 44 parking spaces are needed. 18. Landscape plan needed. 19. Lighting plan needed. 20. Show parking space dimensions for compact cars. 21. Only 10 percent of required spaces can be compact. TRC Minutes 07.02.26 Page 2 of 3 22. A landscaped area shall be provided at the end of each parking area adjacent to the travel lane serving the parking aisle. Building: No comments Fire: 23. All portions of the building must be within required fire access distance. Revise the plan to demonstrate compliance. 24. Provide a fire apparatus turning exhibit to confirm that emergency vehicles can access all areas of the site. 25. Fire hydrants shall be spaced in accordance with City standards (maximum spacing measured along the roadway). Provide a dimensioned exhibit demonstrating compliance. 26. Based on the proposed occupancy/load, additional fire protection systems (e.g., sprinklers, fire alarm) may be required. Revise plans to demonstrate compliance with applicable code provisions. Planning: 27. Cross-access between adjacent properties is required to support interconnected vehicular circulation and minimize direct access points to the public right-of- way. Revise the site plan to provide a cross-access connection to both adjacent parcels. CR-26-33: Courtesy Review – Mother-in-Law Suite Addition – 903 23rd Ave North Attending Customer Representatives: Travis Yates, Applicant Staff Comments Public Works: No comments Zoning: 1. The R-1 zoning district permits one single-family dwelling unit per lot. A dwelling unit is defined as separate living quarters that include cooking, sleeping, and sanitary facilities for exclusive use by a household. 2. Possible solutions: Add on to existing dwelling, meeting requirements of all zoning, building and flood ordinances. Expansion of existing home without adding a second dwelling unit. 3. Applicant can appeal zoning administrator's decision to the BZA that the submitted drawings are showing an additional dwelling unit. Building: 4. Must comply with Zoning and Flood Zone requirements. 5. Flood zone ordinances will allow for a completely separate single-family residence or an addition to the existing non-conforming structure that meets current flood zone ordinances. Accessory structures are limited to no more than 100 sq ft and are not allowed to have any habitable space. Fire: No comments Planning: No comments Z-26-13: Minor PDD Amendment to Robbers Roost for Vinyl Fencing in Common Area Attending Customer Representatives: Monica Powell, Applicant Staff Comments Public Works: No comments Zoning: 1. I want to post a rezoning sign in the area the fence is planned. Building: No comments TRC Minutes 07.02.26 Page 3 of 3 Fire: No comments Planning: 2. This item will require Planning Commission review prior to approval and is scheduled for the July 21, 2026, meeting. CR-26-1: Courtesy Review – Coconuts Tiki Bar 38x40 Covered Patio Attending Customer Representatives: Bill Robinson, Contractor Staff Comments Public Works: No comments Zoning: 1. Poolside Activities (Sec. 23-118): Proposed poolside activities shall comply with Sec. 23-118, including guest-only use, no outside storage, a maximum of 100 sq. ft. of enclosed space (or FEMA maximum, whichever is less), a maximum of 1,200 sq. ft. of total roofed area, compliance with setbacks and impervious surface limits, and seating limited to one (1) seat per two (2) guest rooms, with no additional parking required. 2. 15' rear yard setback (Ocean Side) 3. 5' side yard setback (North Side) Building: No comments Fire: 4. Show egress path from the patio. Planning: No comments

Source: City of North Myrtle Beach website. First collected Oct 13, 2026.