_04302026-532
City of North Myrtle Beach · Horry County · meeting of Apr 30, 2026 · Minutes
Open the original document More from City of North Myrtle Beach
Text
Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.
TRC Minutes 04.30.26 Page 1 of 3
TECHNICAL REVIEW COMMITTEE MINUTES
Thursday, April 30, 2026 – 10:00 A.M.
Planning & Development Conference Room/Zoom
NEW APPLICATIONS
CR-26-25: Courtesy Review – 16 EV Tesla Charging Stations – 4835 Highway 17 South
Attending
Customer
Representatives:
Cameron Frueh, Applicant
Staff Comments
Public Works: No comments
Zoning: No comments
Building: 1. Tesla manufacturers specs required at permitting.
2. See Fire Marshall Note.
Fire: 3. Will need bollards and a Knox ESTOP switch.
4. Current NFPA 70 (2020)
625.43 Disconnecting Means.
For EVSE and WPTE rated more than 60 amperes or more than 150 volts to
ground, the disconnecting means shall be provided and installed in a readily
accessible location. If the disconnecting means is installed remote from the
equipment, a plaque shall be installed on the equipment denoting the location
of the disconnecting means. The disconnecting means shall be lockable open in
accordance with 110.25.
Planning: 5. This project does not require Technical Review Committee (TRC) review.
Please proceed directly with a building permit application. All applicable code
requirements will be reviewed as part of the permitting process.
CR-26-26: Courtesy Review – Commercial Development - PIN: 38900000002
Attending
Customer
Representatives:
Dustin Briggs, Applicant
Staff Comments
Public Works: 1. Update layout for gas station, there is no longer an entrance on Water Tower
Rd.
2. Stormwater to meet City Stormwater Design Manual guidelines.
3. Provide a minimum 20’ access drive behind long building for fire access.
4. Show dumpster locations for the long building.
5. Dumpsters at grocery building appear to be front load - which required private
service. See City standard details for minimum dumpster pad/screening
requirements. Confirm adequate maneuvering room.
6. Verify driveway spacing meets SCDOT Arms manual spacing requirements.
7. Extend Henry Road per City standards. Turnaround required at the end of the
public street. See the City’s Street Planning Manual for roadway design
requirements. Center road within Right-of-Way.
TRC Minutes 04.30.26 Page 2 of 3
8. Provide as-built of existing pond if used for site stormwater drainage per
standards. Refer to SCDES Engineer's checklist. Downstream analysis
required. Address offsite easements and pond maintenance responsibility.
9. GSWSA service area. Coordinate water and sewer extensions with GSWSA.
10. Additional comments reserved.
Zoning: 11. Major PDD amendment needed.
12. Review Sec. 23-29 of the zoning ordinance.
Building: No comments
Fire: 13. Have we established utility placement yet? All portions of the building must be
within required fire access distance. Revise the plan to demonstrate compliance.
14. Provide a fire apparatus turning exhibit to confirm that emergency vehicles can
access all areas of the site.
15. Fire hydrants shall be spaced in accordance with City standards (maximum
spacing measured along the roadway). Provide a dimensioned exhibit
demonstrating compliance.
Planning: 16. Major PDD amendment required. Pattern book uploaded for commercial
development architecture standards. Recommend including signage in initial
proposal to avoid delays in permitting.
17. This item will also require Planning Commission review prior to approval as a
major subdivision plat improving Henry Road.
18. Provide a continuous, accessible pedestrian connection between the public
sidewalk on Henry and the primary building entrance. Revise the site plan to
clearly show the route and associated improvements.
TRC-26-8: Site Plan – Ocean & Oak – 4403 Highway 17 South
Attending
Customer
Representatives:
Cameron Parker, Engineer
Staff Comments
Public Works: 1. Remove driveway connection for the back parking lot to the pharmacy.
2. Revise dumpster access so that trucks can turn around on-site before entering
the right-of-way.
3. Label grinder pump as “Owned and Maintained by Owner (Private)”.
4. Remove note 11 under Utility Notes on sheet C2.0.
5. Update landscape plan to match revised site plan. Show site triangles at all
driveways.
Zoning: No comments
Building: No comments
Fire: No comments
Planning: 6. Relocate the sidewalk connection to link with the public sidewalk, extending it
through the parking lot to the front entrance of the building.
TRC-26-9: Site Plan – Temporary Pay Parking Lot – 2004 North Ocean Boulevard
Attending
Customer
Representatives:
Mark Hardee, Developer
Staff Comments
TRC Minutes 04.30.26 Page 3 of 3
Public Works: 1. Pay kiosk location may be problematic. Clarify intent/location of pay kiosk.
Drive-up or walk-up? Gated?
2. Clarify traffic flow at entrance; add pavement marking/arrows as required.
3. SCDOT encroachment permit required for driveway.
4. Show existing light pole location.
Zoning: No comments
Building: No comments
Fire: No comments
Planning: No comments
SUB-25-79: Major Preliminary Plat – Tilghman Estates - PIN: 35604020024
Attending
Customer
Representatives:
James Baldwin, Engineer
Staff Comments
Public Works: 1. Review proposed sidewalk elevations vs. edge of pavement elevations. Sidewalk
is higher than the roadway in places.
2. Revisit landscape plan, trees are shown on utilities and at intersections. Add site
triangles.
3. Provide utility easements over water and/or sewer lines where lines are close to
property lines.
4. City Attorney to review the proposed Maintenance Agreement.
Zoning: No comments
Building: No comments
Fire: No comments
Planning: 5. Replace Japanese Zelkova street tree with a native species.
6. Can go on 5/19 PC Agenda.
Source: City of North Myrtle Beach website. First collected Oct 13, 2026.