RecordWell Data

Historic Preservation Commission (PDF)

Town of Bluffton · Beaufort County · meeting of Apr 7, 2021 · Agendas

Open the original document More from Town of Bluffton

Text

Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.

TOWN OF BLUFFTON HISTORIC PRESERVATION COMMISSION ELECTRONIC MEETING Wednesday, April 7, 2021 6:00p.m. PUBLIC COMMENT Public comments will be received via conference line provided by Staff. All requests for public hearing or public comment will be accepted up to two (2) hours prior to the scheduled meeting start time. This meeting can be viewed on the Town of Bluffton’s Facebook page https://www.facebook.com/TownBlufftonSC/ I. CALL TO ORDER II. ROLL CALL III. NOTICE REGARDING ADJOURNMENT The Historic Preservation Commission will not hear new items after 9:30 p.m. unless authorized by a majority vote of the Commission Members present. Items which have not been heard before 9:30 p.m. may be continued to the next regular meeting or a special meeting date as determined by the Commission Members. IV. NOTICE REGARDING PUBLIC COMMENTS* Every member of the public who is recognized to speak shall address the Chairman and in speaking, avoid disrespect to Commission, Staff, or other members of the Meeting. State your name and address when speaking for the record. COMMENTS ARE LIMITED TO THREE (3) MINUTES. V. ADOPTION OF AGENDA VI. ADOPTION OF MINUTES – March 3, 2021 VII. PUBLIC COMMENTS FOR ITEMS NOT ON THE AGENDA* VIII. OLD BUSINESS IX. NEW BUSINESS A. Certificate of Appropriateness: A request by Sawyer Graham and Preston Glover, on behalf of the owners on behalf of the owner, Town of Bluffton Historic Preservation Commission Agenda April 7, 2021 Page 2 William Glover, for approval of a Certificate of Appropriateness to the construction of a new one and a half-story single-family structure of approximately 2,604 SF and a Carriage House of approximately 880 SF located at 7 Pearl Street, Lot 20 in the Tabby Roads Development, in the Old Town Bluffton Historic District and zoned Neighborhood General-HD. (COFA-02-21-014972) (Staff- Katie Peterson) X. DISCUSSION No discussion. XI. ADJOURNMENT NEXT MEETING DATE– Wednesday, May 5, 2021 * Public Comments may be submitted electronically via the Town’s website at (https://bit.ly/TOBPublicComment ) or by emailing your comments to the Growth Management Coordinator at dmclain@townofbluffton.com. Comments will be accepted up to 2 hours prior to the scheduled meeting start time. All comments will be read aloud for the record and will be provided to the Historic Preservation Committee. “FOIA Compliance – Public notification of this meeting has been published and posted in compliance with the Freedom of Information Act and the Town of Bluffton policies.” In accordance with the requirements of Title II of the Americans with Disabilities Act of 1990 ("ADA"), the Town of Bluffton will not discriminate against qualified individuals with disabilities on the basis of disability in its services, programs, or activities. EXECUTIVE SESSION - The public body may vote to go into executive session for any item identified for action on the agenda. Any person requiring further accommodation should contact the Town of Bluffton ADA Coordinator at 843.706.4500 or adacoordinator@townofbluffton.com as soon as possible but no later than 48 hours before the scheduled event. Town of Bluffton  Historic Preservation Commission Page 1 of 5 March 3, 2021 TOWN OF BLUFFTON HISTORIC PRESERVATION COMMISSION Electronic Meeting Wednesday, March 3, 2021, Minutes Present: Bruce Trimbur - Chair; Elaine Gallagher Adams- Vice Chair; Michael Lovecchio; Jesse Solomon; Mary Vaux Bell; and Kerri Schmelter Staff: Katie Peterson, Senior Planner; Charlotte Moore, Principal Planner; and, Darby McLain, Growth Management Coordinator I. CALL TO ORDER Chairman Trimbur called the meeting to order at 6:04 p.m. II. ROLL CALL All members were present. III. NOTICE REGARDING ADJOURNMENT The Historic Preservation Commission will not hear new items after 9:30 P.M. unless authorized by a majority vote of the Commission Members present. Items which have not been heard before 9:30 P.M. may be continued to the next regular meeting or an additional meeting date as determined by the Commission members. IV. NOTICE REGARDING PUBLIC COMMENTS Every member of the public who is recognized to speak shall address the Chairman and in speaking, avoid disrespect to the Commission, Town Staff, and other members of the meeting. State your name and address when speaking for the record. UNLESS OTHERWISE AMENDED BY THE HISTORIC PRESERVATION COMMISSION, COMMENTS ARE LIMITED TO THREE (3) MINUTES. V. ADOPTION OF THE AGENDA Vice Chair Gallagher-Adams made a motion to adopt the agenda. Commissioner Schmelter seconded the motion. All were in favor and the motion passed. VI. ADOPTION OF MINUTES Commissioner Vaux-Bell made a motion to adopt the February 3, 2021 Minutes as presented with revision to the motion in items three. Vice Chair Gallagher-Adams seconded the motion. All were in favor the motion passed. Town of Bluffton  Historic Preservation Commission Page 2 of 5 March 3, 2021 VII. PUBLIC COMMENTS FOR ITEMS NOT ON THE AGENDA There were no public comments. VIII. OLD BUSINESS There was no old business. IX. NEW BUSINESS A. Certificate of Appropriateness: A request by Ansley Manuel, on behalf of the owner, Patricia Ellen Malphrus, for approval of owners, James Mitchell and Laurie Brown, for approval of a Certificate of Appropriateness to allow addition of approximately 1,034 SF to the existing single-family structure of approximately 1,546 SF located at 38 Lawrence Street in the Old Town Bluffton Historic District and zoned Neighborhood General-HD. (COFA-12- 20-014812) (Staff- Katie Peterson) Staff Katie Peterson presented the information to the Commission which is included in these minutes. Vice Chair Gallagher-Adams motioned to approve the application with the following conditions: 1. Per Section 5.15.6.P., the Plywood in the Soffit must be revised to a permitted material. 2. Per Section 5.15.6.J., a gutter profile must be provided to ensure it is rectangle, square or half round in profile. 3. Per Section 5.15.5.E.8. and Traditional Construction Patterns, the proposed chimney should be revised to be bricked to match the existing, or the existing chimneys refaced to math the new proposed. 4. Per Section 5.15.6.G.1.a. the exposed foundation shall be changed to Mixed Shell size tabby stucco. 5. Per Section 5.15.6.E., a chimney cap detail must be provided to ensure it is in keeping with masonry building technology. 6. The Commission determined that the first-floor finished height is appropriate to be below 3 feet from average adjacent sidewalk grade as it is an addition to an existing structure. 7. The Commission determined that the porch height is appropriate as submitted as it is an addition to an existing structure. Town of Bluffton  Historic Preservation Commission Page 3 of 5 March 3, 2021 8. Per Section 3.22.2.A., a Town of Bluffton Tree Removal Permit must be obtained for any tree 14” (DBH) or greater on a single-family lot and proposed for removal. Commissioner Vaux-Bell seconded the motion. All were in favor and the motion passed. B. Certificate of Appropriateness: A request by Court Atkins Architects, on behalf of the owner, Herkus, LLC, for approval of a Certificate of Appropriateness to allow the construction of a new 2 1/2 -story Mixed-Use building of approximately 5,272 heated square feet located at 10 Marianna Way, Building 5 in the Old Village Square development, in the Old Town Bluffton Historic District and zoned Neighborhood General – HD. (Staff- Katie Peterson)(COFA-01-21-014894) Staff member Katie Peterson presented the information to the commission which is incorporated into these minutes. Commissioner Solomon motioned to approve the application with the following conditions: 1. Per Section 5.15.6.A., The Commission found the use of false windows to be inappropriate. 2. Additional information on the configuration of the false windows on the rear elevation was unnecessary due to the windows being removed. 3. The Floor Plans or Elevations and Wall Section must be updated to reflect the partitions on the second-floor porch. 4. The Elevations or Wall Sections must be revised to reflect the same roofing material. 5. Per the Applications Manual, the Application must be signed by both the applicant and the owner. Vice Chair Gallagher-Adams seconded the motion. All were in favor and the motion passed. C. Certificate of Appropriateness: A request by DH Abney Company, on behalf of the owners, Donna and James Brancato, for approval of a Certificate of Appropriateness to allow the construction of a 1.5-story single-family residential structure of approximately 2,373 SF and a 2-story Carriage House of approximately 1,093 SF located at 22 Stock Farm Road, Lot 34 in the Stock Farm Development in the Old Town Bluffton Historic Town of Bluffton  Historic Preservation Commission Page 4 of 5 March 3, 2021 District, and zoned Neighborhood General-HD. (COFA-01-21-014894) (Staff- Katie Peterson) Staff Katie Peterson presented the information to the commission which is incorporated into these minutes. Commissioner Solomon motioned to approve the application with the following conditions: 1. Per the Applications Manual, the Site Plan must be updated to show the driveway location and configuration. 2. Per Section 5.3.3.C., the Carriage House shall be moved North to preserve the existing canopy from the 20” 12” split trunk Laurel Oak tree labeled on the Site Plan. An arborist report per Section 3.22.2. of the Unified Development Ordinance, by an arborist not removing the tree, must be provided in conjunction with the Tree Removal Plan showing the declined health of the tree and mitigation provided or the Carriage House location revised to avoid the root system of the existing tree. The Tree Removal Plan shall be review by the Historic Preservation Review Committee and approved at staff level. 3. Per Section 3.18., the raise deck and swim spa, must be removed from the Landscape Plan as not enough information was provided to complete the review. 4. Per Section 5.15.6.E.8., the chimney cap must be removed from all elevations to match Left Elevation. The chimney cap must be drawn on the plans and a detail provided to ensure it meets the requirements of section 5.15.6.E.8. 5. Per Section 5.15.6.H. the railing and balustrades must be revised to termite resistant wood, painted or natural wrought or cast iron. 6. Per Section 5.15.6.E.5. the porch height must be revised to be 30” minimum to top of stairs. 7. Per Section 5.15.5.F.1.c the first finished floor height must be raised to be a minimum of thee (3) feet above average adjacent sidewalk grade. 8. The Commission determined the use of a false window (closed shutter) was not appropriate and the window should be either a true window or removed and the siding continued to be in compliance with Section 5.15.6. 9. Per Section 5.15.6.A. and 5.15.6.M., the shutters must be revised to be a durable wood material or additional information on the composite Town of Bluffton  Historic Preservation Commission Page 5 of 5 March 3, 2021 proposed to ensure the shutters will be consistent with the character of the Historic District and the materials used are of equal or better quality than traditional building materials. 10. Per Section 5.15.6.M., a shutter dog profile must be provided for review. 11. Per Section 5.15.6.J., a gutter profile must be provided to ensure they will be rectangle, square or half round in profile. 12. The Commission determined that the material for the gas chimney on the screen porch must be monolithic in the material to not change material on an exterior corner. 13. The Commission found the use of awning windows as a substitute to be appropriate. 14. Per Section 5.15.5.F.4. shutters shall be added to all windows that can accept them, specifically, they must be added on the Carriage House. 15. Per Section 5.3.3.G. the Landscape Plan must be revised to show the requirement of 75 percent lot coverage with tree canopy measured as the mature canopy, not including rooftops has been met. 16. Per Section 3.22.2.A., a Town of Bluffton Tree Removal Permit must be obtained for any tree 14” (DBH) or greater located on a single- family lot and proposed for removal. 17. Per Section 5.15.6.E.7.2., the porch is to be shifted to center to allow the doors and gable (including the window in the second story) to be centered on the columns. Vice Chair Gallagher-Adams seconded the motion. All were in favor and the motion passed. X. DISCUSSION No discussion. XI. ADJOURNMENT Vice Chair Gallagher-Adams made a motion to adjourn the March 3, 2021 Historic Preservation Commission meeting. Commissioner Schmelter seconded the motion, and all were in favor. The meeting was adjourned at 8:30 p.m. 7 Pearl Street, Lot 20 – Certificate of Appropriateness Historic Preservation Commission HISTORIC PRESERVATION COMMISSION STAFF REPORT Department of Growth Management MEETING DATE: April 7, 2021 PROJECT: Lot 20, 7 Pearl Street – New Construction: Single- Family Residential APPLICANT: Sawyer Graham and Preston Glover PROJECT MANAGER: Katie Peterson, AICP, Senior Planner APPLICATION REQUEST: The Applicant, Sawyer Graham and Preston Glover, on behalf of William Glover, requests that the Historic Preservation Commission approve the following application: 1. COFA-02-21-014972. A Certificate of Appropriateness to allow the construction of a new one and a half-story single-family structure of approximately 2,604 SF and a Carriage House of approximately 880 SF located at 7 Pearl Street, Lot 20 of the Tabby Roads Development, in the Old Town Bluffton Historic District and zoned Neighborhood General-HD. INTRODUCTION: The Applicant is proposing the construction of a detached single- family residence located in the Old Town Bluffton Historic District. The proposed building, of approximately 2,604 SF, has similar attributes of the Village House, but is not 2 stories in height, so it is reviewed as an Additional Building Type in accordance with the allowable building types for the Neighborhood General-HD zoning district. In addition to the primary structure, the Applicant is proposing a Carriage House structure of approximately 880 SF, which meets the design standards for a Carriage House Building Type. This lot is located within the Tabby Roads development plan, which specifies lot fronts Pearl Street and has a 6-foot front setback, 10-foot rear setback, 7.5-foot left and right setbacks. The proposed placement meets these setbacks. The main house structure is under a two-story cross gabled roof with the side- facing gable closer to the front of the structure. It features full-length front and rear porches both under hipped roofs. The rear porch is screened in. At the rear of the structure, an unconditioned breezeway attaches the primary structure to the Carriage House. The proposed materials include combination of horizontal and vertical siding, tabby stucco foundation and chimney, and a combination of shingle and metal roofs. The Carriage House also features a cross gable roof and similar materials and trim detailing as the primary structure. April 7, 2021 Page 2 7 Pearl Street, Lot 20 – Certificate of Appropriateness Historic Preservation Commission This project was presented to the Historic Preservation Review Committee for conceptual review at the March 8, 2021 meeting and comments were provided to the Applicant (See attachment 6). HISTORIC PRESERVATION COMMISSION ACTIONS: As granted by the powers and duties set forth in Section 2.2.6.E.2, the Historic Preservation Commission has the authority to take the following actions with respect to this application: 1. Approve the application as submitted by the Applicant; 2. Approve the application with conditions; or 3. Deny the application as submitted by the Applicant. It is important to note that the intent of Section 5.15 Old Town Bluffton Historic District of the Unified Development Ordinance (UDO) is that the Section be user friendly and informative to the residents and the members of HPC and is not intended to discourage creativity or force the replication of historic models. Rather, it is to set forth a framework in which the diversity that has always characterized Bluffton can continue to grow. The Section also defines guidelines for design and materials similar to that used on structures within the Old Town, and it is the charge of the HPC to assess the interpretation of these guidelines as they pertain to applications using the established review criteria. REVIEW CRITERIA & ANALYSIS: Town Staff and the Historic Preservation Commission are required to consider the criteria set forth in Section 3.18.3 of the UDO in assessing an application for a Certificate of Appropriateness – Historic District (HD). The applicable criteria are provided below followed by a Staff Finding(s) based upon review of the application submittals to date. 1. Section 3.18.3.B. Consistency with the principles set forth in the Old Town Master Plan. a. Finding. The application is consistent with the principles set forth in the Old Town Master Plan. The Old Town Master Plan states that, “The built environment, in particular the historic structures scattered throughout Old Town, should be protected and enhanced. While it is of great importance to save and restore historic structures, it is just as important to add to the built environment in a way that makes Old Town more complete.” The Applicant proposes to construct a new single-family residence and Carriage House within the Old Town Bluffton Historic District, a locally and nationally designated historic district. The buildings have been designed to be sympathetic to the architectural character of the neighboring historic structures, so their addition to the architectural diorama will both protect the integrity of the existing historic structures and enhance the neighborhood by adding architectural variety. b. Finding. The Old Town Master Plan initiatives also include the adoption of a form-based code that included architectural standards for structures located within the Old Town Bluffton Historic District. These standards are included in Article 5 of the UDO. The new construction proposed as April 7, 2021 Page 3 7 Pearl Street, Lot 20 – Certificate of Appropriateness Historic Preservation Commission part of this request will be in conformance with those standards if the conditions noted in item 2 of this Section are met. c. Finding. The Old Town Master Plan initiatives also promote preservation and protection of the legacy of the Old Town Bluffton Historic District through additions to the built environment which make Old Town more complete. The addition of the proposed residential structure and Carriage House add to the district as well as help provide completeness to the neighborhood and overall district. 2. Section 3.18.3.C. The application must be in conformance with applicable provisions provided in Article 5, Design Standards. a. Finding. Town Staff finds that the design of the primary structure falls within the category of Additional Building Type as allowed in the Neighborhood General Historic District per Section 5.15.5.C. Additional Building Types are permissible. As has been past practice, the Town Staff requests the Historic Preservation Commission review and make a final recommendation regarding the appropriateness of the Additional Building Type. b. Finding. Town Staff finds that if the conditions noted below are met, the proposed addition will be in conformance with applicable provisions provided in Article 5: 1) Section 5.15.6.J. Roofs and Gutters. Metal roofs must be revised to be Galvanized, Copper, Aluminum, Zinc-Alum material and have a profile of either Standing Seam or 5-V Crimp 24” maximum spacing with panel ends exposed at overhang in profile. The plans show the use of a metal roof but there is not enough information to complete the review. Additional detail must be provided. 2) Section 5.15.6.J. Roofs and Gutters. Shingle roofs must be Metal or Asphalt “dimensional” type, Slate, Composite Slate material and be Square, Rectangular, Fish Scale, Diamond in profile. The plans show the use of shingles, but there is not enough information to complete the review. Additional detail must be provided. 3) Section 5.15.6.I. Windows and Doors. Door material must be wood, metal, or metal-clad. There is not enough information to complete the review. Additional information on a door schedule must be provided for review. 4) Section 5.15.6.I. Windows and Doors. Windows with true divided lite or simulated divided lite are encouraged. The window detail does not provide enough information to determine the configuration. Additional information on a window schedule must be provided for review. April 7, 2021 Page 4 7 Pearl Street, Lot 20 – Certificate of Appropriateness Historic Preservation Commission 5) Section 5.15.6.G. Building Walls. Exposed foundation walls (below the first floor elevation) shall be; Brick done in bond patterns; Painted brick; Tabby stucco (mixed shell size only); or Stucco over block or concrete (sand-finished or steel trowel only). The foundation is noted to have Tabby finish, but the size is not noted. Additional information must be provided to ensure the tabby finish is mixed shell size only or it is another permitted material. 6) Section 5.15.5.F. General Standards. Residential structures shall have a first finished floor height raised a minimum of three (3) feet above average adjacent sidewalk grade. The first finished floor height can be elevated as much as five (5) feet above average adjacent sidewalk grade without counting the undercroft as a story. When scaled, the elevations show the first finished floor height at 3 feet, however it is labeled to check the site plan, which shows the finished floor height at approximately 5.9 feet above average adjacent sidewalk grade. The site plan must be updated to be no less than 3 feet and no more than five feet above average adjacent sidewalk grade. Should the finished floor height exceed 3.5 feet, a grading plan must be provided for review. 7) Section 5.15.6.E.5. Porches. Porches shall be a minimum of 30 inches from grade to top of stairs with a maximum of 96 inches from grade to top of stairs. When scaled, the elevations show the porch height at 33 inches, however it is labeled to check the site plan, which shows the front porch height at approximately 64 inches above adjacent grade. The site plan and elevations must be updated to be consistent. 8) Section 5.15.6.E. Porches. Porches may be screened; however, if screened, all architectural expression (columns, railings, pickets, etc.) must occur on the outside of the screen (facing the street or public space). The rear porch is shown as screened, but a detail has not been provided. Additional information must be provided to ensure all architectural expression occurs outside of the screen. 9) Section 5.15.6.P. Cornice, Soffit, and Frieze. Rough sawn wood, plywood and aluminum are not permitted materials for soffit or cornice detailing. All wall section details show plywood material in the soffits and must be revised to a permitted material. 10) Section 5.15.6.E.8. Chimneys, Roof Appurtenances, and Roof Penetrations. In keeping with masonry building technology, metal spark arrestors, exposed metal flues, or pre-fabricated chimney caps are not permitted. Detail A-202 shows a 24 inch standing seam chimney cap. The chimney cap must be revised to a permitted configuration. 11) Section 5.15.6.N. Corners and Water Tables. Water table skirt boards shall be a minimum 5/4 stock and furred out to sit just April 7, 2021 Page 5 7 Pearl Street, Lot 20 – Certificate of Appropriateness Historic Preservation Commission beyond the face of the foundation wall (after finish foundation material is applied, i.e. brick, stucco). The plans show a 2x material drip board with a 1x material skirt board. The skirt board must be revised to a minimum of 5/4 stock. 12) Section 5.15.6.H. Columns, Arches, Piers, Railings, Balustrades. Railings shall be wood (termite resistant), painted or natural Wrought or Cast Iron. They shall have a top rail of 2-3/4” minimum diameter; Balusters shall be 4” on center spacing minimum with a 5” on center spacing maximum. A railing detail must be provided for review. 13) Section 5.15.7. Garages. Driveways shall be a maximum of 10 feet wide in front of the principal plane of the building. The plans show the driveway at 13 feet 10 inches in front of the principal plane of the building. The driveway must be narrowed to no wider than 10 feet in front of the principal plane of the building. 3. Section 3.18.3.D. Consistency with the nature and character of the surrounding area and consistency of the structure with the scale, form and building proportions of the surrounding neighborhood. Finding. Town Staff finds the nature and character of the new construction to be consistent and harmonious with that of the surrounding neighborhood. The mass and scale of the structures are appropriate for their location and the architectural detailing is sensitive to the neighboring properties. 4. Section 3.18.3.F. The historic, architectural, and aesthetic features of the structure including the extent to which its alteration or removal would be detrimental to the public interest. Finding. The Applicant seeks approval for the construction of new structures in the Old Town Bluffton Historic District. The proposed plans are sympathetic in design to the neighboring historic and non-historic resources; therefore, the structure, as proposed, will have no adverse effect on the public interest. 5. Section 3.18.3.H. The application must comply with applicable requirements in the Applications Manual. Finding. The Certificate of Appropriateness Application has been reviewed by Town Staff and has been determined to be complete, however, the following items must be addressed prior to approval of this application: 1) As the lot is located within the Tabby Roads Development, a letter of approval from the HARB must be submitted. April 7, 2021 Page 6 7 Pearl Street, Lot 20 – Certificate of Appropriateness Historic Preservation Commission STAFF RECOMMENDATION: It is the charge of the HPC to assess and interpret the standards and guidelines set forth in the UDO as they pertain to applications using the review criteria established in the UDO and to take appropriate action as granted by the powers and duties set forth in Section 2.2.6.E.2. Town Staff finds that with the conditions noted below, the requirements of Section 3.18.3 of the Unified Development Ordinance have been met and recommends that the Historic Preservation Commission approve the application with the following conditions: 1. Per Section the Applications Manual, Final Approval from the Tabby Roads HARB must be obtained and submitted to Town Staff. 2. Per Section 5.15.6.J., the metal roofs must be revised to be Galvanized, Copper, Aluminum, Zinc-Alum material and have a profile of either Standing Seam or 5-V Crimp 24” maximum spacing with panel ends exposed at overhang. 3. Per Section 5.15.6.J., the shingle roofs must be revised to be Metal or Asphalt “dimensional” type, Slate, Composite Slate material and be Square, Rectangular, Fish Scale, Diamond in profile. 4. Per Section 5.15.6.I., additional information on the doors must be provided to ensure they will be to be wood, metal, or metal-clad. 5. Per Section 5.15.6.I., additional information must be provided to ensure the windows are true divided lite or simulated divided lite (not snap-in or between the glass). 6. Per Section 5.15.6.G., additional information must be provided on the Tabby Stucco at the foundation to ensure it is mixed shell size. 7. Per Section 5.15.5.F., the first finished floor height on the elevations and site plan must match and be a minimum of three (3) feet above average adjacent sidewalk grade and a maximum of 5 feet above average adjacent sidewalk grade. Additionally, if the finished floor height exceeds 3.5 feet, a grading plan must be provided for the site to ensure the grade change will not affect drainage onto other lots. 8. Per Section 5.15.6.E.5., the porch height on the elevations and floor plans must be revised to match and be 30” minimum from grade to top of stairs; 96” maximum. 9. Per Section 5.15.6.E.5., a screen detail must be provided. 10.Per Section 5.15.6.P., plywood in the soffits must be removed and replaced with an approvable material. 11.Per Section 5.15.6.E.8., the chimney cap must be revised to one in keeping with masonry building technology. April 7, 2021 Page 7 7 Pearl Street, Lot 20 – Certificate of Appropriateness Historic Preservation Commission 12.Per Section 5.15.6.N., the water table skirt boards must be revised from a 1x material to be a minimum 5/4 stock and furred out to sit just beyond the face of the foundation wall (after finish foundation material is applied, i.e. brick, stucco). 13.Per Section 5.15.6.H. a railing and balustrade detail must be provided for review. 14.Per Section 5.15.7., the driveway must be narrowed to no wider than 10 feet in front of the principal plane of the building. ATTACHMENTS: 1. Location Map 2. Zoning Map 3. Application & Applicant Narrative 4. Site Plan & Elevations 5. Landscape Plan 6. HPRC Report 2 1 3 5 7 2 6 4 6 4 8 5 1E B ru in R d B lu e C ra b S tW ild Spartina St 2 6 3 0 3 2 3 6 3 4 2 4 2 8 8 2 92 72 5 3 53 33 1 Burnt Church Rd B a ite rs W a lk PearlSt W ild Spartina St T a b b y S h e ll R d 17 1 6 0 3 14 2 5 9 BurntChurch Rd B ru in R d Lost Hollow Ln PearlSt 7 5 16 1 15 9 15 7 15 1 Burnt Church Rd PearlSt Tabby Shell Rd 7 Pearl - Location Map 3 / 3 0 / 2 0 2 1 0 0 . 0 1 0 . 0 2 0 . 0 3 0 . 0 4 0 . 0 50 . 0 1 m i F I n f o L a y e r P a r c e l P r o p e r t y L in e s ATTACHMENT 1 1 3 5 7 2 6 4 4 8 5 1E B ru in R d B lu e C ra b S tW ild Spartina St 2 6 3 0 3 2 3 6 3 4 2 4 2 8 2 92 72 5 3 53 33 1 Burnt Church Rd B a ite rs W a lk PearlSt W ild Spartina St T a b b y S h e ll R d 17 1 6 0 3 14 2 BurntChurch Rd B ru in R d Lost Hollow Ln PearlSt 7 5 16 1 15 9 15 7 15 1 Burnt Church Rd LostHollow Ln PearlSt Tabby Shell Rd 2 3 7 Pearl - Zoning Map 3 / 3 0 / 2 0 2 1 0 0 . 0 1 0 . 0 2 0 . 0 3 0 . 0 4 0 . 0 50 . 0 1 m i F I n f o L a y e r P a r c e l P r o p e r t y L in e s ATTACHMENT 2 ATTACHMENT 3 ATTACHMENT 3 ATTACHMENT 3 ATTACHMENT 3 ATTACHMENT 3 ATTACHMENT 3 Project Narrative for the Proposed Glover Residence Located at 7 Pearl Street We propose to build a two-story single-family residence with approximately 2,602 heated square feet, along with a matching carriage house with 440 heated square feet (880 total) located at 7 Pearl Street, Identified as Lot 20 in the Tabby Roads development, In the Old Town Bluffton Historic District and zoned Neighborhood General-HD. The carriage house will be slab on grade, while the main structure will be a raised monolithic slab with turndowns. The exposed slab and chimney will be finished in tabby stucco. The covered porches and stairs to said porches will be finished in tabby with brick borders and brick stairs. The structures will be framed with spruce lumber and engineered beams, trusses, and strapping per engineering specs. The structures will be fully clad with Hardie (fiber cement siding). The stairs in the portico, the carriage house stairs, service yard, privacy fence, and all brackets, handrails, drink rails, posts, and balusters will be premium kdat treated lumber. The main roofs of the structures will be architectural asphalt shingles, while all porch roofs, shed roofs, and breezeway roof will be standing seam metal. Windows will be black vinyl. The front door will be solid core wood stained to match the rough sawn cypress columns. (All other exterior doors, will be painted) We have included with this application: -A tree and topographical survey of the property. -Digital and hardcopies of our architectural plans, including floor plans, roof plans, site plan, elevations, and architectural details. -Digital and hardcopies of our landscape design. Please allow this full size plan to also serve as our tree removal plan. It indicates with red exes each tree on the property to be removed (location, size, and species) However, to further clarify our tree removal plan, we have included our previous rough sketch of our site plan with the trees we plan to keep circled in red along with the narrative we submitted in our tree removal application to the town. This narrative notes the number of each species of tree we will need to remove. ATTACHMENT 3 REVIEW - 00SINGLE USE ONLY . 21 - 013 PEARL STREET PEARL STREET GENERAL PROJECT NOTES 00 L - 100 DRAWING NOTES SCALE: 1" = 10'-0" SITE PLAN L - 100 - 1 WYER AS E N V I S I O ND E S I G NB U I L D STRUCTURAL INFORMATION DESIGN LOADS I.R.C. - 2018 ICC 600-2014 x STRUCTURAL INFORMATION DESIGN LOADS I.R.C. - 2018 ICC 600-2014 x SCALE: 1/8" = 1'-0" EXTERIOR ELEVATION - STREET CONTEXT L - 100 - 2 GARAGE SERVICE YARD FRONT COVERED PORCH FIRST FLOOR BACKCOVERED PORCH ATTACHMENT 4 REVIEW - 00SINGLE USE ONLY . 21 - 013 PEARL STREET PEARL STREET GENERAL PROJECT NOTES 00 A - 100 DRAWING NOTES SCALE: 1/4" = 1'-0" SECOND FLOOR PLAN - MAIN HOUSE A - 100 - 2 WYER AS E N V I S I O ND E S I G NB U I L D STRUCTURAL INFORMATION DESIGN LOADS I.R.C. - 2018 ICC 600-2014 x STRUCTURAL INFORMATION DESIGN LOADS I.R.C. - 2018 ICC 600-2014 x GARAGE BAY NO. 2 000 GARAGE BAY NO. 1 000 MASTER BEDROOM 000 STUDY 000 DINING ROOM 000 LAUNDRY 000 M - BATH 000 LIVING ROOM 000 KITCHEN 000 BACK COVERED PORCH 000 POWDER 000 FOYER 000 FRONT COVERED PORCH 000 MUD 000 ATTACHMENT 4 REVIEW - 00SINGLE USE ONLY . 21 - 013 PEARL STREET PEARL STREET GENERAL PROJECT NOTES 00 A - 101 DRAWING NOTES WYER AS E N V I S I O ND E S I G NB U I L D STRUCTURAL INFORMATION DESIGN LOADS I.R.C. - 2018 ICC 600-2014 x STRUCTURAL INFORMATION DESIGN LOADS I.R.C. - 2018 ICC 600-2014 x SCALE: 1/4" = 1'-0" SECOND FLOOR PLAN - MAIN HOUSE A - 100 - 2 LIVING ROOM 000 KITCHEN 000 BEDROOM 000 BATH 000 BEDROOM NO.1 000 BEDROOM NO. 2 000 BATH NO. 1 000 BATH NO. 2 000 ATTACHMENT 4 REVIEW - 00SINGLE USE ONLY . 21 - 013 PEARL STREET PEARL STREET GENERAL PROJECT NOTES 00 A - 102 DRAWING NOTES SCALE: 1/8" = 1'-0" SECOND FLOOR PLAN - WINDOWS AND DOORS A - 102 - 2 WYER AS E N V I S I O ND E S I G NB U I L D STRUCTURAL INFORMATION DESIGN LOADS I.R.C. - 2018 ICC 600-2014 x STRUCTURAL INFORMATION DESIGN LOADS I.R.C. - 2018 ICC 600-2014 x SCALE: 1/8" = 1'-0" FIRST FLOOR PLAN - WINDOW AND DOORS A - 102 - 1 EGRESS MANUFACTURE ALIGNMENT SHOP DRAWINGS NOTES WINDOWS AND DOORS AND SIZES PRIOR TO VERIFY ALL SPECIFICATIONS ORDERING AND INSTALLATION DOOR SWING I I H A G G I G C G G G G I I I I I I I IIGI I I IFFF E E H I H D I B I I C SCALE: 1/4" = 1'-0" WINDOW AND DOOR NOTES A - 102 - 3 A SCALE: 1-1/2" = 1'-0" WINDOW TRIM DETAIL A - 102 - 5 SCALE: 1/2" = 1'-0" WINDOW AND DOOR TRIM A - 102 - 4 B C D E F G H I 4 44 ATTACHMENT 4 REVIEW - 00SINGLE USE ONLY . 21 - 013 PEARL STREET PEARL STREET GENERAL PROJECT NOTES 00 A - 102 DRAWING NOTES SCALE: 1/8" = 1'-0" SECOND FLOOR PLAN - WINDOWS AND DOORS A - 102 - 2 WYER AS E N V I S I O ND E S I G NB U I L D STRUCTURAL INFORMATION DESIGN LOADS I.R.C. - 2018 ICC 600-2014 x STRUCTURAL INFORMATION DESIGN LOADS I.R.C. - 2018 ICC 600-2014 x SCALE: 1/8" = 1'-0" FIRST FLOOR PLAN - WINDOW AND DOORS A - 102 - 1 EGRESS MANUFACTURE ALIGNMENT SHOP DRAWINGS NOTES WINDOWS AND DOORS AND SIZES PRIOR TO VERIFY ALL SPECIFICATIONS ORDERING AND INSTALLATION DOOR SWING I I H A G G I G C G G G G I I I I I I I IIGI I I IFFF E E H I H D I B I I C SCALE: 1/4" = 1'-0" WINDOW AND DOOR NOTES A - 102 - 3 A SCALE: 1-1/2" = 1'-0" WINDOW TRIM DETAIL A - 102 - 5 SCALE: 1/2" = 1'-0" WINDOW AND DOOR TRIM A - 102 - 4 B C D E F G H I 4 44 ATTACHMENT 4 REVIEW - 00SINGLE USE ONLY . 21 - 013 PEARL STREET PEARL STREET GENERAL PROJECT NOTES 00 A - 200 DRAWING NOTES SCALE: 1/4" = 1'-0" EXTERIOR ELEVATION - LEFT A - 200 - 1 WYER AS E N V I S I O ND E S I G NB U I L D STRUCTURAL INFORMATION DESIGN LOADS I.R.C. - 2018 ICC 600-2014 x STRUCTURAL INFORMATION DESIGN LOADS I.R.C. - 2018 ICC 600-2014 x SCALE: 1/4" = 1'-0" EXTERIOR ELEVATION - FRONT A - 200 - 2 12-12 12-12 12-12 12-12 12-12 12-12 3-12 3-12 3-12 3-12 ATTACHMENT 4 REVIEW - 00SINGLE USE ONLY . 21 - 013 PEARL STREET PEARL STREET GENERAL PROJECT NOTES 00 A - 201 DRAWING NOTES WYER AS E N V I S I O ND E S I G NB U I L D STRUCTURAL INFORMATION DESIGN LOADS I.R.C. - 2018 ICC 600-2014 x STRUCTURAL INFORMATION DESIGN LOADS I.R.C. - 2018 ICC 600-2014 x SCALE: 1/4" = 1'-0" EXTERIOR ELEVATION - RIGHT A - 201 - 1 SCALE: 1/4" = 1'-0" EXTERIOR ELEVATION - BACK A - 201 - 2 12-12 12-12 12-12 12-12 12-12 12-12 3-12 3-12 3-12 3-12 4 4 ATTACHMENT 4 REVIEW - 00SINGLE USE ONLY . 21 - 013 PEARL STREET PEARL STREET GENERAL PROJECT NOTES 00 A - 202 DRAWING NOTES WYER AS E N V I S I O ND E S I G NB U I L D STRUCTURAL INFORMATION DESIGN LOADS I.R.C. - 2018 ICC 600-2014 x STRUCTURAL INFORMATION DESIGN LOADS I.R.C. - 2018 ICC 600-2014 x SCALE: 1/4" = 1'-0" EXTERIOR ELEVATION - RIGHT A - 202 - 2 SCALE: 1/4" = 1'-0" EXTERIOR ELEVATION - BACK A - 202 - 1 12-1212-12 12-1212-12 3-123-12 2-122-12 SCALE: 1/4" = 1'-0" EXTERIOR ELEVATION - RIGHT - WITH FENCE A - 202 - 3 SCALE: 3/4" = 1'-0" CHIMNEY CAP DETAIL A - 202 - 4 4 ATTACHMENT 4 REVIEW - 00SINGLE USE ONLY . 21 - 013 PEARL STREET PEARL STREET GENERAL PROJECT NOTES 00 A - 400 DRAWING NOTES SCALE: 1" = 1'-0" WALL DETAIL - COVERED PORCH A - 400 - 4 WYER AS E N V I S I O ND E S I G NB U I L D STRUCTURAL INFORMATION DESIGN LOADS I.R.C. - 2018 ICC 600-2014 x STRUCTURAL INFORMATION DESIGN LOADS I.R.C. - 2018 ICC 600-2014 x SCALE: 1" = 1'-0" WALL DETAIL - LOW ROOF PLATE A - 400 - 2 SCALE: 1" = 1'-0" WALL DETAIL - TYPICAL A - 400 - 1 SCALE: 1" = 1'-0" WALL DETAIL - INTERIOR FOOTING A - 400 - 3 SCALE: 1" = 1'-0" WALL DETAIL - TYPICAL CORNER A - 400 - 5 ATTACHMENT 4 REVIEW - 00SINGLE USE ONLY . 21 - 013 PEARL STREET PEARL STREET GENERAL PROJECT NOTES 00 A - 301 DRAWING NOTES WYER AS E N V I S I O ND E S I G NB U I L D STRUCTURAL INFORMATION DESIGN LOADS I.R.C. - 2018 ICC 600-2014 x STRUCTURAL INFORMATION DESIGN LOADS I.R.C. - 2018 ICC 600-2014 x SCALE: 1/8" = 1'-0" ROOF PLAN A - 301 - 1 ROOF PLAN - DETAILS DRAWING NOTES HIP OVERHANGS GABLE OVERHANGS ROOF PITCH STRAPPING RAFTERS DESIGN LOADS SHEATHING PRELIMINARY WATER PROOFING STRUCTURAL HARDWARE TREATED WOOD FASTENERS ROOF PITCH 12 - 12 SEE NOTES FOR CLARIFICATION ROOF SHINGLES 12-12 12-12 12-12 12-1212-12 12-12 12-12 12-12 12-1212-12 12-1212-12 12-1212-12 12-1212-12 3-12 3-12 3-12 3-12 3-12 ATTACHMENT 4 REVIEW - 00SINGLE USE ONLY . 21 - 013 PEARL STREET PEARL STREET 3-12 GENERAL PROJECT NOTES 00 A - 401 DRAWING NOTES WYER AS E N V I S I O ND E S I G NB U I L D STRUCTURAL INFORMATION DESIGN LOADS I.R.C. - 2018 ICC 600-2014 x STRUCTURAL INFORMATION DESIGN LOADS I.R.C. - 2018 ICC 600-2014 x SCALE: 1" = 1'-0" WALL DETAIL - CARRIAGE HOUSE A - 401 - 1 SCALE: 1" = 1'-0" WALL DETAIL - DOOR SHED ROOF A - 401 - 3 SCALE: 1" = 1'-0" WALL DETAIL - SERVICE YARD A - 401 - 2 ATTACHMENT 4 16' 8' 0 4' 8' SCALE: 1/8"= 1'-0"1 SHEET OF phone: (843) 816-3518 Bluffton, SC 29910 BGR 1/8"= 1'-0"SCALE: DATE: DRAWN BY: 1 25 Palmetto Beach Drive Rose Landscape, LLC Preliminary Landscape Plan for William Glover Bluffton SC 29910 THIS DOCUMENT AND ALL REPRODUCIBLE COPIES OF THIS DOCUMENT ARE THE PROPERTY OF ROSE LANDSCAPE, LLC. ANY REPRODUCTION OF THIS DOCUMENT WITHOUT THE PERMISSION OF ROSE LANDSCAPE, LLC IS PROHIBITED. ANY ALTERATIONS TO THIS DOCUMENT ARE PROHIBITED. N PLANT LIST: notes: 1. Cover all disturbed areas with mulch or pine straw to prevent erosion. 2. Contractor to provide 100% irrigation coverage for all newly installed plant material. www.roselandscape.com qty Sizeremarks Quercus virginianasouthern live oak165gal3" caliper Azalea formosalavender formosa azalea53 gal Azalea formosalavender formosa azalea37 gal camellia JaponicaPInk Japanese camellia17gal dianella tasmanicavariegated flax lily123 gal dietes iridioidesaFrican iris31gal Fatsia japonicaJapanese aralia37gal hydrangea M. 'nikko Blue'Nikko Blue Hydrangea23gal lantana m. 'chapel hill'Chapel hill yellow lantana7 1gal Ligustrum japonicawaxleaf ligustrum815gal loropetalum c. 'red chocolate'Red Chocolate loropetalum67 gal nerium oleander 'ice pink'Dwarf pink oleander57gal Osmanthus fragransTea Olive115gal podocarpus m. MetaMeta dwarf podocarpus127gal podocarpus macrophyllaJapanese plum yew515 gal Trachelospermum jasminoidesConfederate jasmine 131gal36" oc. on fence Empire zoysia sod1,050 sf Residence japanese camellia 7 gallon (1) 3/10/21 v. flax lily 3 gal (12) Hydrangea 3 gal (2) lawn #7 Pearl Street Landscape Plan dwf Podocarpus 7 gal (6) Tea olive 15 gal (1) lantana 1 gal (7) dwf oleander 3 gal (5) Loropetalum 7 gal (3) Podocarpus 15 gal (5) Azalea 7 gal (3) Southern live oak 65 gal (1) azalea 3 gallon (5) arfican iris 1 gallon (3) loropetalum 7 gal (3) EDGE OF EX. TREE CANOPY PINESTRAW lawn PINESTRAW LIVING FENCE W/ CONFEDERATE JASMINE 36" O.C 1 gal (13) proposed live oak canopy 3,404 sf ex. Tree canopy 2,350 sf Tree canopy calculations total site square footage8,766 sf Total Building foot print, including all out buildings3,230 sf Site area less building foot print5,536 sf Proposed new canopy coverage3,404 sf Existing tree canopy2,350 sf Total canopy coverage5,754 sf Site area with no coverage 1,130 sf proposed percentage of site coverage87.10% total area with no canopy 1,130 sf total bldg footprint 3,230 sf Tree Canopy Coverage fatsia 7 gal (3) shi shi gashira camellia 7 gal (6) garage drive 36" 52" 48" 2" x 4" Steel wire mesh 2" x 4" Rail 1" x 4" cap 2" x 4" Rail 6" x 6" post gate Steel Wire Fence Detail SCALE N.T.S. Note: fence to be painted to match house trim stepping stone (typ.) #7 Pearl Street ATTACHMENT 5 PLAN REVIEW COMMENTS FOR COFA-02-21-014972 Town of Bluffton Department of Growth Management 20 Bridge Street P.O. Box 386 Bluffton, South Carolina 29910 Telephone 843-706-4522 OLD TOWN Plan Type: Apply Date: Plan Status: Plan Address: 7 Pearl St Street BLUFFTON, SC 29910 Historic District Active 02/09/2021 Plan PIN #:Case Manager: R610 039 000 1201 0000Katie Peterson Plan Description: A request Sawyer Graham and Preston Glover, on behalf of the owner, William Glover, for review of a Certificate of Appropriateness to allow the construction of a new two-story single-family residence of approximately 2,500 SF and a Carriage House of approximately 880 SF located at 7 Pearl Street, identified as Lot 20 in the Tabby Roads Development, in the Old Town Bluffton Historic District and zoned Neighborhood General-HD. STATUS: The Application will be heard at the March 8th HPRC Meeting. Staff Review (HD) Submission #: 1 Recieved: 02/22/2021 Completed: 03/05/2021 Reviewing Dept. Complete Date StatusReviewer Approved with Conditions03/05/2021Growth Management Dept Review (HD) Katie Peterson Comments: 1. As the project moves toward Final submittal, provide a landscape plan noting foundation plantings, street trees and canopy coverage, typical window detail, chimney cap detail, a railing detail, a corner board detail, water table detail and a section through the exterior wall and eave as not enough information was provided in submittal to review these items for conformance with the UDO. Additionally, the items listed in the narrative as changes to the drawings will need to be incorporated into the final submittal plans. (Applications Manual) 2. Driveways shall be a maximum of 10 feet in width in front of the principal plane of the building. The current site plan shows the driveway wider than 10 feet in front of the principal plane and it must be reduced to meet this requirement. (UDO 5.15.7.H.) 3.There will likely be further comment once updated drawings have been submitted. Approved with Conditions03/05/2021HPRC Review Katie Peterson Comments: 1. Consider the location of trash can storage when finalizing service yard details. (UDO 5.15.5.F.10) 2. Long unarticulated masses shall be avoided. The house is on a corner lot. Preference would be to choose a floorplan that wraps the corner with a porch or treats both sides as the front elevation. It is likely possible for this floorplan to work, but the applicant should study the Tabby Shell Road elevation to make it feel more polished. It may make sense to mirror the floorplan so the more public rooms – Office / Dining Room are facing Tabby to allow a better window rhythm. (UDO 5.15.5.F.2.d.) 3. For context - Would be Helpful to see Tabby Shell Elevation with proposed fence & Pearl Street Elevation in relation to 5 Pearl Street. Approved03/05/2021Beaufort Jasper Water and Sewer Review James Clardy Comments: 1.No comments. Approved03/05/2021Building Safety Review Richard Spruce Comments: 1. Building Safety will provide review at time of permit submittal. Approved03/05/2021Transportation Department Review - HD William Howard 03/05/2021 Page 1 of 2 ATTACHMENT 6 Comments: 1. No comment. Approved03/05/2021Watershed Management Review Bridgette Noonan Comments: 1. No Comment. Approved02/25/2021Addressing Review Nick Walton Comments: 1. No comments. Plan Review Case Notes: 03/05/2021 Page 2 of 2 ATTACHMENT 6

Source: Town of Bluffton website. First collected Oct 14, 2026.