Historic Preservation Committee Agenda (PDF)
Town of Bluffton · Beaufort County · meeting of Mar 3, 2021 · Agendas
Open the original document More from Town of Bluffton
Text
Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.
TOWN OF BLUFFTON
HISTORIC PRESERVATION COMMISSION
ELECTRONIC MEETING
Wednesday, March 3, 2021 6:00p.m.
PUBLIC COMMENT
Public comments will be received via conference line provided by Staff. All requests
for public hearing or public comment will be accepted up to two (2) hours prior to the
scheduled meeting start time.
This meeting can be viewed on the Town of Bluffton’s Facebook page
https://www.facebook.com/TownBlufftonSC/
I. CALL TO ORDER
II. ROLL CALL
III. NOTICE REGARDING ADJOURNMENT
The Historic Preservation Commission will not hear new items after 9:30
p.m. unless authorized by a majority vote of the Commission Members
present. Items which have not been heard before 9:30 p.m. may be
continued to the next regular meeting or a special meeting date as
determined by the Commission Members.
IV. NOTICE REGARDING PUBLIC COMMENTS*
Every member of the public who is recognized to speak shall address the
Chairman and in speaking, avoid disrespect to Commission, Staff, or other
members of the Meeting. State your name and address when speaking for
the record. COMMENTS ARE LIMITED TO THREE (3) MINUTES.
V. ADOPTION OF AGENDA
VI. ADOPTION OF MINUTES – February 3, 2021
VII. PUBLIC COMMENTS FOR ITEMS NOT ON THE AGENDA*
VIII. OLD BUSINESS
IX. NEW BUSINESS
A. Certificate of Appropriateness: A request by Ansley Manuel, on
behalf of the owners on behalf of the owners, James Mitchell and
Town of Bluffton
Historic Preservation Commission Agenda
March 3, 2021
Page 2
Laurie Brown, for approval of a Certificate of Appropriateness to
allow addition of approximately 1,034 SF to the existing single-
family structure of approximately 1,546 SF located at 38 Lawrence
Street in the Old Town Bluffton Historic District and zoned
Neighborhood General-HD. (COFA-12-20-014812) (Staff-Katie
Peterson)
B. Certificate of Appropriateness: A request by Court Atkins Architects,
on behalf of the owner, Herkus, LLC, for approval of a Certificate of
Appropriateness to allow the construction of a new 2 1/2 -story
Mixed-Use building of approximately 5,272 heated square feet
located at 10 Marianna Way, Building 5 in the Old Village Square
development, in the Old Town Bluffton Historic District and zoned
Neighborhood General – HD. (COFA-01-21-014894) (Staff-Katie
Peterson)
C. Certificate of Appropriateness: A request by DH Abney Company,
on behalf of the owners, Donna and James Brancato, for approval
of a Certificate of Appropriateness to allow the construction of a
1.5-story single-family residential structure of approximately 2,373
SF and a 2-story Carriage House of approximately 1,093 SF located
at 22 Stock Farm Road, Lot 34 in the Stock Farm Development in
the Old Town Bluffton Historic District, and zoned Neighborhood
General-HD. (COFA-10-20-014637) (Staff – Katie Peterson)
X. DISCUSSION
No discussion.
XI. ADJOURNMENT
NEXT MEETING DATE– Wednesday, April 7, 2021
* Public Comments may be submitted electronically via the Town’s website at
(https://bit.ly/TOBPublicComment ) or by emailing your comments to the Growth Management Coordinator at
dmclain@townofbluffton.com. Comments will be accepted up to 2 hours prior to the scheduled meeting start time.
All comments will be read aloud for the record and will be provided to the Historic Preservation Committee.
“FOIA Compliance – Public notification of this meeting has been published and posted in compliance with the
Freedom of Information Act and the Town of Bluffton policies.”
In accordance with the requirements of Title II of the Americans with Disabilities Act of 1990 ("ADA"), the Town
of Bluffton will not discriminate against qualified individuals with disabilities on the basis of disability in its
services, programs, or activities.
EXECUTIVE SESSION - The public body may vote to go into executive session for any item identified for action on the agenda.
Town of Bluffton
Historic Preservation Commission Agenda
March 3, 2021
Page 2
Any person requiring further accommodation should contact the Town of Bluffton ADA Coordinator at
843.706.4500 or adacoordinator@townofbluffton.com as soon as possible but no later than 48 hours before the
scheduled event.
Town of Bluffton Historic Preservation Commission
Page 1 of 5
February 3, 2021
TOWN OF BLUFFTON HISTORIC PRESERVATION COMMISSION
Electronic Meeting
Wednesday, February 3, 2021, Minutes
Present: Bruce Trimbur - Chair; Elaine Gallagher Adams- Vice Chair; Michael
Lovecchio; Jesse Solomon; Mary Vaux Bell; and Kerri Schmelter
Staff: Katie Peterson, Senior Planner; Charlotte Moore, Principal Planner; and,
Darby McLain, Growth Management Coordinator
I. CALL TO ORDER
Chairman Trimbur called the meeting to order at 6:02 p.m.
II. ROLL CALL
All members were present.
III. NOTICE REGARDING ADJOURNMENT
The Historic Preservation Commission will not hear new items after 9:30 P.M.
unless authorized by a majority vote of the Commission Members present. Items
which have not been heard before 9:30 P.M. may be continued to the next regular
meeting or an additional meeting date as determined by the Commission members.
IV. NOTICE REGARDING PUBLIC COMMENTS
Every member of the public who is recognized to speak shall address the Chairman
and in speaking, avoid disrespect to the Commission, Town Staff, and other
members of the meeting. State your name and address when speaking for the
record. UNLESS OTHERWISE AMENDED BY THE HISTORIC PRESERVATION
COMMISSION, COMMENTS ARE LIMITED TO THREE (3) MINUTES.
V. ADOPTION OF THE AGENDA
Commissioner Schmelter made a motion to adopt the agenda. Vice Chair
Gallagher-Adams seconded the motion. All were in favor and the motion passed.
VI. ADOPTION OF MINUTES
Commissioner Solomon made a motion to adopt the January 6, 2021 Minutes with
the addition that Vice Chair Gallagher Adams be marked present at the last
meeting. Vice Chair Gallagher-Adams seconded the motion. All were in favor the
motion passed.
Town of Bluffton Historic Preservation Commission
Page 2 of 5
February 3, 2021
VII. ELECTION OF OFFICERS – Election for vice-chair and Historic Preservation Review
Committee Member
Commissioner Schmelter motioned to remove this item from the agenda as it was
voted on during the last meeting. Vice Chair Gallagher-Adams seconded the
motion. All were in favor and the motion passed.
VIII. PUBLIC COMMENTS FOR ITEMS NOT ON THE AGENDA
There were no public comments.
IX. OLD BUSINESS
There was no old business.
X. NEW BUSINESS
A. Certificate of Appropriateness: A request by Ansley Manuel, on behalf of
the owner, Patricia Ellen Malphrus, for approval of a Certificate of
Appropriateness to allow an addition of approximately 2,971 SF to the
existing single-family structure of approximately 1,095 SF located at 114
Pritchard Street in the Old Town Bluffton Historic District and zoned
Neighborhood Conservation-HD. (COFA-12-20-014811) (Staff-Katie
Peterson)
Staff Katie Peterson presented the information to the Commission which is
included in these minutes.
Commissioner Solomon made a motion to approve the application with the
following conditions:
1. Per Section 5.15.5.F.4., the HPC determined the overall building proportions
and individual building features have a proportional relationship with one
another as the new addition will be the primary mass of the structure upon
completion and the existing structure a secondary wing.
2. Per Section 5.15.6.A., the HPC determined the use of Stainless-Steel Cables
in the railings on the balcony is a substitute material for those listed in
Section 5.15.6.H.2.d. of the UDO as it is on a rear elevation, will be low
profile and will withstand the elements better than those listed in the UDO at
this location.
3. Per Section 5.15.6.A., the HPC determined the use of a circular window on
the east elevation was a substitute material for those listed in 5.15.6.I.3.a of
the UDO as there is precedent in many local houses for the use of a circular
Town of Bluffton Historic Preservation Commission
Page 3 of 5
February 3, 2021
window shape as a decorative detail.
4. Per Section 5.15.6.A., the HPC determined the use of a circular window on
the west elevation was a substitute material for those listed in 5.15.6.I.3.a of
the UDO as there is precedent in many local houses for the use of a right
trapezoid window shapes as a decorative detail.
5. The HPC determined that as the existing structure does not have a finished
floor height, it is appropriate that the addition does not meet the required 3
feet, but rather matches that of the existing structure. Staff requests a height
be added to the elevations to ensure it matches at time of construction.
6. The HPC determined that as the finished floor height will match the existing,
the porch height is appropriate at 2’ 9” from adjacent grade as meeting the
minimum in section 5.15.6.E.5.c., would require a step up.
7. Per Section 5.15.6.A., the HPC determined that the use of a concrete block
foundation sealed and painted to match the existing cottage and better define
the relationship between the new and existing construction is an appropriate
substitute for those materials listed in Section 5.15.6.G.1.a. of the UDO.
8. Per Section 5.15.7.D.1. the parking area must be relocated to the side
(behind the front plane of the structure) or rear of the structure.
9. Per Section 3.22.2.A., a Town of Bluffton Tree Removal Permit must be
obtained for any tree 14” (DBH) or greater located on a single-family lot and
proposed for removal.
10. Per Section 5.3.3.G., the landscape plan must be updated to show the site
meets the 75% lot coverage with tree canopy measured as the mature
canopy, not included rooftops.
11. Per Section 5.15.6.H., a detail of the underpinning on the pier porches must
be submitted for review.
Vice Chair Gallagher-Adams seconded the motion. All were in favor and the
motion passed.
B. Certificate of Appropriateness: A request by Court Atkins Architects, on
behalf of the owner, Herkus, LLC, for approval of a Certificate of
Appropriateness to allow the construction of a new 2 1/2 -story Mixed-Use
building of approximately 5,272 heated square feet located at 6 Marianna
Way, Building 4 in the Old Village Square development, in the Old Town
Bluffton Historic District and zoned Neighborhood General – HD. (Staff-
Katie Peterson)(COFA-01-21-014892)
Commissioner Lovecchio made a motion to approve the application with
the following conditions:
Town of Bluffton Historic Preservation Commission
Page 4 of 5
February 3, 2021
1. Per Section 5.15.6.J., the fiberglass shingles must be replaced with a permitted
roof material.
2. Per Section 5.3.7.E. the landscape plan must be revised to show plantings in the
areas which had porches shown on the Development Plan and now are not within
the porch/building footprint.
3. Per Section 5.15.6.M., the shutter dog profile must be provided for review.
4. Per Section 5.15.6.N., a corner board detail must be provided for review.
5. The HPC determined that the proportion of the central portico relative to the
overall width of the building was appropriate per Section 5.15.F.4. and is
approved as drawn
6. The HPC determined that as it is the rear elevation and additional glazing would
result in the installation of false windows or detailing, the glazing on the rear
elevation was appropriate as submitted.
7. Per Section 5.7.6.A. the site plan must be revised to provide a dedicated and
improved pedestrian walkway between the commercial space and the parking
area and the ADA compliant space and commercial and residential units.
Commissioner Schmelter seconded the motion. After a discussion between
Commissioners, Commissioner Schmelter made a motion to amend the original
motion to include the following conditions:
1. Per Section 5.15.F.4 the proportion of the central portico relative to the
overall width of the building should be restudied.
2. Per Section 5.15.F.4., the glazing on the rear elevation should be restudied to
reduce large areas of blank walls on the rear elevation.
Commissioner Vaux-Bell seconded the motion to amend the primary motion.
All were in favor to the amended motion and it passed.
Commissioner Schmelter made a motion to approve the primary and amended
motion to allow the approve application with conditions.
All were in favor to amend the primary motion and the amended motion.
XI. DISCUSSION
No discussion.
XII. ADJOURNMENT
Town of Bluffton Historic Preservation Commission
Page 5 of 5
February 3, 2021
Commissioner Vaux-Bell made a motion to adjourn the February 3, 2021 Historic
Preservation Commission meeting. Vice Chair, Gallagher-Adams, seconded the
motion, and all were in favor. The meeting was adjourned at 8:11 p.m.
38 Lawrence Street – Certificate of Appropriateness Historic Preservation Commission
HISTORIC PRESERVATION
COMMISSION
STAFF REPORT
Department of Growth Management
MEETING DATE: March 3, 2021
PROJECT: 38 Lawrence Street– Addition to Single-Family
Residential
APPLICANT: Ansley H. Manuel, Architect
PROJECT MANAGER: Katie Peterson, AICP, Senior Planner
APPLICATION REQUEST: The Applicant, Ansley H. Manuel, on behalf of the owners,
James Mitchell and Laurie Brown, requests that the Historic Preservation
Commission approve the following application:
1. COFA-12-20-014812. A Certificate of Appropriateness for the addition of
approximately 1,034 SF to the existing single-family structure of
approximately 1,546 SF located at 38 Pritchard Street in the Old Town
Bluffton Historic District and zoned Neighborhood General-HD.
INTRODUCTION: The Applicant is proposing the construction of a 1,034 SF addition
to the existing primary structure located at 38 Lawrence Street in the Old Town
Bluffton Historic District. According to Beaufort County records, the single-family
residence was originally constructed in approximately 2002, with an addition in
2008. While the existing structure likely classifies as a Village House Building Type,
the structure, with the proposed addition will not meet one of the permitted
Building Types for the Neighborhood General-HD zoning district, and therefore shall
be reviewed as an Additional Building Type in accordance with Section 5.15.5.C. of
the Unified Development Ordinance (UDO).
The existing structure is a two-story cement shingle sided structure with a two-
story front porch. It is oriented on the lot facing the east, which is not the front of
the lot. The proposed addition, which will be added to the front of the structure
(right side if using the lot orientation), will bring the structure’s front into
compliance with the lot standards found in the UDO.
The addition removes the existing two-story porch and adds a one story side-facing
gable addition to the center and a forward facing gable to the far right side. The
addition proposes to use the same cement shingle siding and standing seam roof
material as the existing structure. It will also feature windows will the same lite
pattern.
This project was presented to the Historic Preservation Review Committee for
conceptual review at the January 4, 2021 meeting and comments were provided to
March 3, 2021 Page 2
38 Lawrence Street – Certificate of Appropriateness Historic Preservation Commission
the Applicant (See Attachment 5).
HISTORIC PRESERVATION COMMISSION ACTIONS: As granted by the powers and
duties set forth in Section 2.2.6.E.2, the Historic Preservation Commission has the
authority to take the following actions with respect to this application:
1. Approve the application as submitted by the Applicant;
2. Approve the application with conditions; or
3. Deny the application as submitted by the applicant.
It is important to note that the intent of Section 5.15 Old Town Bluffton Historic
District of the Unified Development Ordinance (UDO), is that the Section be user
friendly and informative to the residents and the members of HPC and is not
intended to discourage creativity or force the replication of historic models. Rather,
it is to set forth a framework in which the diversity that has always characterized
Bluffton can continue to grow. The Section also defines guidelines for design and
materials similar to that used on structures within the Old Town, and it is the
charge of the HPC to assess the interpretation of these guidelines as they pertain to
applications using the established review criteria.
REVIEW CRITERIA & ANALYSIS: Town Staff and the Historic Preservation
Commission are required to consider the criteria set forth in Section 3.18.3 of the
UDO in assessing an application for a Certificate of Appropriateness – Historic
District (HD). The applicable criteria are provided below followed by a Staff
Finding(s) based upon review of the application submittals to date.
1. Section 3.18.3.B. Consistency with the principles set forth in the Old Town
Master Plan.
a. Finding. The application is consistent with the principles set forth in the
Old Town Master Plan. The Old Town Master Plan states that, “The built
environment, in particular the historic structures scattered throughout Old
Town, should be protected and enhanced. While it is of great importance
to save and restore historic structures, it is just as important to add to the
built environment in a way that makes Old Town more complete.”
The Applicant proposes an addition to an existing single-family residential
structure within the Old Town Bluffton Historic District, a locally and
nationally designated historic district. The building has been designed to
be sympathetic to the architectural character of the neighboring historic
structures, so its addition to the architectural diorama will both protect
the integrity of the existing historic structures and enhance the
neighborhood by adding architectural variety.
b. Finding. The Old Town Master Plan initiatives also include the adoption of
a form-based code that included architectural standards for structures
located within the Old Town Bluffton Historic District. These standards
are included in Article 5 of the Unified Development Ordinance. The
addition proposed as part of this request will be in conformance with
those standards if the conditions noted in item 2 of this Section are met.
March 3, 2021 Page 3
38 Lawrence Street – Certificate of Appropriateness Historic Preservation Commission
c. Finding. The Old Town Master Plan initiatives also promote preservation
and protection of the legacy of the Old Town Bluffton Historic District
through additions to the built environment which make Old Town more
complete. The proposed addition will continue to provide completeness to
the neighborhood and overall district.
2. Section 3.18.3.C. The application must be in conformance with applicable
provisions provided in Article 5, Design Standards.
a. Finding. Town Staff finds that the design of the structure falls within the
category of Additional Building Type within the Neighborhood General
Historic District per Section 5.15.5.C. As the Commission with approval
authority in accordance with article 2 of the UDO, the HPC has final
approval authority on the appropriateness of an Additional Building Type
within this zoning district. Town Staff requests the Historic Preservation
Commission review and make a final recommendation regarding the
appropriateness of the Additional Building Type.
b. Finding. Town Staff finds that if the conditions noted below are met, the
proposed addition will be in conformance with applicable provisions
provided in Article 5:
1) Section 5.15.6.J. Roofs and Gutters. Gutters may be Rectangular
section, Square section, Half-round section. Gutters are proposed
on the application, however, a profile was not provided. A gutter
profile must be provided to ensure compliance with this section.
2) Section 5.15.6.E.8. Chimneys. In keeping with masonry building
technology, metal spark arrestors, exposed metal flues, or
prefabricated chimney caps are not permitted. Additional
information on the proposed chimney cap must be provided as not
enough information as provided to review.
3) Section 5.15.6.P. Cornice, Soffit and Eaves. Rough sawn wood,
plywood and aluminum are not permitted materials for soffit or
cornice detailing. Detail A and B on Sheet A9 as well as the
application notes the use of plywood in the soffit. The soffit
material must be revised to a permitted material.
4) Section 5.15.5.E.8. Exterior chimneys shall be finished in brick,
tabby, or stucco. While the application proposes the chimney on
the new addition to be Tabby stucco, the existing structure already
has two chimneys (one brick, one cement board shingles). The
addition of a third chimney material is not consistent and should
be revised to be brick (as the cement shingles are an existing
nonconforming material) to match the existing structure.
Alternately, the chimneys on the existing structure could be
reworked to be Tabby stucco to match the proposed addition.
5) Section 5.15.5.F.1.c. General Standards. The first-floor finish
height must be 3 feet above the average adjacent sidewalk grade.
March 3, 2021 Page 4
38 Lawrence Street – Certificate of Appropriateness Historic Preservation Commission
As this is an addition to an existing structure, the Applicant is
requesting a deviation from the requirement of the 3-foot finished
floor height. Staff recommends the deviation be allowed,
however, requires that the finished floor height, at least from
adjacent grade, for the existing structure be labeled on the
elevations to ensure the addition will match at time of
construction.
6) Section 5.15.6.E.5.c. Porches. Porches are required to have a
minimum height of 30 inches minimum from the adjacent grade to
the top of stairs. The porch height must be raised. The height of
the porch must be increased to meet this requirement.
7) Section 5.15.6.G.1.a. Building Walls. Exposed foundation walls
(below the first-floor elevation) shall be Brick done in bond
patterns; Painted brick; Tabby stucco (mixed shell size only); or
Stucco over block or concrete (sand-finished or steel trowel only).
The application proposes the foundation be Size One Shell Tabby
Stucco. The material must be revised to be a permitted material.
3. Section 3.18.3.D. The nature and character of the surrounding area and
consistency of the structure with the harmony of the surrounding
neighborhood.
Finding. Town Staff finds that nature and character of the addition to the
existing structure is consistent and harmonious with that of the surrounding
neighborhood. The mass and scale of the addition is appropriate for its
location and the architectural detailing is sensitive to the neighboring
properties.
4. Section 3.18.3.F. The historic, architectural, and aesthetic features of the
structure including the extent to which its alteration or removal would be
detrimental to the public interest.
Finding. The Applicant seeks approval for the addition to a single-family
residential structure built in approximately 2002 in the Old Town Bluffton
Historic District. The proposed plans are sympathetic in design to the
neighboring historic and non-historic resources; therefore, the addition, as
proposed, will have no adverse effect on the public interest.
5. Section 3.18.3.H. The application must comply with applicable requirements
in the Applications Manual.
Finding. The Certificate of Appropriateness Application has been reviewed
by Town Staff and has been determined to be complete, however, the
following items must be addressed prior to approval of this application.
1) Per Section 3.22.2.A., a Town of Bluffton Tree Removal Permit is
required for any tree 14” (DBH) or greater located on a single-
March 3, 2021 Page 5
38 Lawrence Street – Certificate of Appropriateness Historic Preservation Commission
family lot and proposed for removal.
STAFF RECOMMENDATION: It is the charge of the HPC to assess and interpret the
standards and guidelines set forth in the UDO as they pertain to applications using
the review criteria established in the UDO and to take appropriate action as granted
by the powers and duties set forth in Section 2.2.6.E.2. Town Staff finds that
requirements of Section 3.18.3 of the Unified Development Ordinance have been
met and recommends that the Historic Preservation Commission approve the
application with the following conditions:
1. Per Section 5.15.6.P., the Plywood in the Soffit must be revised to a
permitted material.
2. Per Section 5.15.6.J., a gutter profile must be provided to ensure it is
rectangle, square or half round in profile.
3. Per Section 5.15.5.E.8. and Traditional Construction Patters, the proposed
chimney should be revised to be brick to match the existing, or the
existing chimneys refaced to match the new proposed.
4. Per Section 5.15.6.G.1.a. the exposed foundation shall be changed to
Mixed Shell size tabby stucco.
5. Per Section 5.15.6.E., a chimney cap detail must be provided to ensure it
is in keeping with masonry building technology.
6. Applicant requests a determination on the appropriateness of the first
finished floor height below 3 feet to match the existing structure. Staff
requests a height be added to the elevations, should this be permitted, to
ensure it matches at time of construction.
7. Per Section 5.15.6.E.5.c., the porch height must be increased to have a
minimum height of 30 inches minimum from the adjacent grade to the
top of stairs.
8. Per Section 3.22.2.A., a Town of Bluffton Tree Removal Permit must be
obtained for any tree 14” (DBH) or greater located on a single-family lot
and proposed for removal.
ATTACHMENTS:
1. Location Map
2. Zoning Map
3. Application and Narrative
4. Site Plan and Elevations
5. Landscape Plan
6. Photos by Applicant
7. HPRC Comments
H
uger
Cove
38 Lawrence St - Location Map
2 / 5 / 2 0 2 1
0 0 . 0 3 0 . 0 5 0 . 0 8 0 . 1 0 . 1 30 . 0 1
m i
F
I n f o L a y e r
P a r c e l P r o p e r t y L in e s
ATTACHMENT 1
H
uger
Cove
38 Lawrence St - Zoning Map
2 / 5 / 2 0 2 1
0 0 . 0 3 0 . 0 5 0 . 0 8 0 . 1 0 . 1 30 . 0 1
m i
F
I n f o L a y e r
P a r c e l P r o p e r t y L in e s
ATTACHMENT 2
ATTACHMENT 3
ATTACHMENT 3
ATTACHMENT 3
ATTACHMENT 3
CV1
PROPOSED SITE PLAN
2/5/21
DATE :
SHEET
MANUEL
STUDIO, LLC
BLUFFTON, SC
100072
ANSLEY HESTER
MANUEL
BLUFFTON, SC
6887
ANILORACHTUOSFOETATS
REGISTERED ARCHITECT
ANILORACHTUOSFOETATS
REGISTERED ARCHITECTS
MANUEL STUDIO, LLC
Ansley Hester Manuel, Architect
104 Pritchard Street, Bluffton, South Carolina 29910
843.338.8932 cell manuel.studio@aol.com
ADDITIONS TO
THE BROWN RESIDENCE
38 LAWRENCE ST. BLUFFTON SOUTH CAROLINA 29910
NEW 1 STORY
ADDITION
83'-6"'
25' B.S.L.
10' B.S.L.
10' B.S.L.
60/40 B.S.L.
PROPOSED SITE PLAN
SCALE: 1"=40'-0"
A
CV1
GRAVEL
PARKING
SPACES
2 NEW
8"CM
GRADE +/- 12"
BELOW FIN. FLR.
GRADE +/- 36"
BELOW FIN. FLR.
GRADE +/- 36"
BELOW FIN. FLR.
GRADE +/- 12"
BELOW FIN. FLR.
ATTACHMENT 4
A1
PROPOSED FOUNDATION PLAN
2/5/21
DATE :
SHEET
MANUEL
STUDIO, LLC
BLUFFTON, SC
100072
ANSLEY HESTER
MANUEL
BLUFFTON, SC
6887
ANILORACHTUOSFOETATS
REGISTERED ARCHITECT
ANILORACHTUOSFOETATS
REGISTERED ARCHITECTS
MANUEL STUDIO, LLC
Ansley Hester Manuel, Architect
104 Pritchard Street, Bluffton, South Carolina 29910
843.338.8932 cell manuel.studio@aol.com
ADDITIONS TO
THE BROWN RESIDENCE
38 LAWRENCE ST. BLUFFTON SOUTH CAROLINA 29910
PROPOSED FOUNDATION PLAN
SCALE: 1/4"=1'-0"
A
A1
8'-31
2"6'-0"8'-31
2"16'-0"3'-0"
41'-7"
14'-0" 10'-8" 5'-8" 2'-0"
3'-0" 4'-0"
32'-4"
8'-0" 4'-0" 22'-7"
41'-7"
15'-4" 12" 22'-3"
2'-10"
2'-10" 15'-10" 2'-10" 3'-8" 2'-10"
8" 2'-2"
18'-4" 12" 3'-1" 2'-10" 10'-11
2" 2'-10" 3'-41
2"
4" CONCRETE SLAB WITH 6X6
W1.4 X W1.4 WWF
OVER 6 MIL VAPOR BARRIER OVER
CLEAN COMPACT AND TREATED SOIL
EXPANSION JOINT
SLOPE
SLAB
CONTROL JOINT
CONTROL JOINT
CONTROL JOINT
CONTROL JOINT
SLOPE
SLAB
Slab Foundation
Existing Concrete
DRILL & EPOXY 4' (#5) REBAR @ 24" O.C.
8" CMU STEM WALL WITH
"L" BLOCK @ TOP COURSE
BRICK OVER MORTAR BED OVER 4" CONCRETE SLAB
WITH 6X6 W1.4 X W1.4 WWF
OVER 6 MIL VAPOR BARRIER OVER
CLEAN COMPACT AND TREATED SOIL
BRICK OVER MORTAR BED OVER
4" CONCRETE SLAB WITH 6X6 W1.4 X W1.4 WWF
OVER 6 MIL VAPOR BARRIER OVER
CLEAN COMPACT AND TREATED SOIL
THICKENED PAD
@ COLUMN
CONTINUOUS TIE ROD @
6'-0" O.C., CORNER,
COLUMNS & ALL OPENINGS
TURNDOWN SLAB @ PORCH WITH BRICK EDGE
16'-0" 22'-7"3'-0"
2'-10" 22'-4" 2'-10"
15'-10" 2'-10" 3'-8" 2'-10"
TOP OF SLAB
TO MATCH
EXISTING SLAB
(SEE B/A10)
THICKENED SLAB
(SEE A/A10)
THICKENED PAD
@ COLUMN
(SEE B/A10)
3'-0"
2'-4"
LINE OF BRICK EDGE @ PORCH
ATTACHMENT 4
A2
EXISTING FIRST FLOOR PLAN
2/5/21
Wood Shop
Deck
Patio Family Room
Dining Room
PorchScreened
Shower Garden
DATE :
SHEET
MANUEL
STUDIO, LLC
BLUFFTON, SC
100072
ANSLEY HESTER
MANUEL
BLUFFTON, SC
6887
ANILORACHTUOSFOETATS
REGISTERED ARCHITECT
ANILORACHTUOSFOETATS
REGISTERED ARCHITECTS
MANUEL STUDIO, LLC
Ansley Hester Manuel, Architect
104 Pritchard Street, Bluffton, South Carolina 29910
843.338.8932 cell manuel.studio@aol.com
ADDITIONS TO
THE BROWN RESIDENCE
38 LAWRENCE ST. BLUFFTON SOUTH CAROLINA 29910
Fireplace
2-Way
Kitchen
EXISTING FIRST FLOOR PLAN
SCALE: 1/4"=1'-0"
A
A2
REMOVE
STOOP
REMOVE TWO STORY
SCREENED PORCH
ATTACHMENT 4
K-520DYNAMETRIC BATH CAST IRON
A3
EXISTING SECOND FLOOR PLAN
2/5/21
DATE :
SHEET
MANUEL
STUDIO, LLC
BLUFFTON, SC
100072
ANSLEY HESTER
MANUEL
BLUFFTON, SC
6887
ANILORACHTUOSFOETATS
REGISTERED ARCHITECT
ANILORACHTUOSFOETATS
REGISTERED ARCHITECTS
MANUEL STUDIO, LLC
Ansley Hester Manuel, Architect
104 Pritchard Street, Bluffton, South Carolina 29910
843.338.8932 cell manuel.studio@aol.com
ADDITIONS TO
THE BROWN RESIDENCE
38 LAWRENCE ST. BLUFFTON SOUTH CAROLINA 29910
Roof of Wood Shop
Deck
Over Patio
Shed Roof
Master Suite
M. Bath
Bedroom
PorchScreened
Shower Garden
EXISTING SECOND FLOOR PLAN
SCALE: 1/4"=1'-0"
A
A3
ATTACHMENT 4
A4
PROPOSED FIRST FLOOR PLAN
2/5/21
DATE :
SHEET
MANUEL
STUDIO, LLC
BLUFFTON, SC
100072
ANSLEY HESTER
MANUEL
BLUFFTON, SC
6887
ANILORACHTUOSFOETATS
REGISTERED ARCHITECT
ANILORACHTUOSFOETATS
REGISTERED ARCHITECTS
MANUEL STUDIO, LLC
Ansley Hester Manuel, Architect
104 Pritchard Street, Bluffton, South Carolina 29910
843.338.8932 cell manuel.studio@aol.com
ADDITIONS TO
THE BROWN RESIDENCE
38 LAWRENCE ST. BLUFFTON SOUTH CAROLINA 29910
Wood Shop
Deck
Patio Family Room
Dining Room
Shower Garden
Fireplace
2-way
Kitchen
Existing
Existing
Existing Existing
Existing
Existing
Existing
ISLAND
Living RoomNew FoyerNew
Master BedroomNew
W.I.C.
New
TUB
W/C
LAV
SHOWER
10'-8" 5'-8" 2'-0"
+/-61'-7"
+/-61'-7"
19'-6"
+/-31'-4" +/-9'-8"
+/-13'-6"+/-17'-10"
BOOKSBOOKS BOOKS
SLOPE
CLG
SLOPE
CLG
R&SH
R&SH
SEAT
SCREEN PORCH
REMOVE 18" COLUMN
BRICK PORCH
LANDING
BRICK
+/-20'-0"41'-7" ADDITION
3'-0"
DOOR & AWNING
REMOVE
Sloped Clg.
Wood Floor
10' Flat Clg.
Wood Floor
12' Flat Clg.
Wood Floor
Master Bathroom
New
12' Flat Clg.
Wood Floor
9' Flat Clg.
Wood Floor
LAV
LINEN
COMP.
W/D
3'-0" C.O.
3'-0"X8'-0"
2'-8"X8'-0"
POCKET
2'-8"X8'-0"
POCKET
2'-4"X8'-0"
2'-8"X8'-0"GLASS2'-0"X8'-0"2'-8"X8'-0"DBL
5'-0" C.O. 3'-0" C.O.
INFILL DOOR @ WALL
ATTIC
ACCESS
PROPOSED FIRST FLOOR PLAN
SCALE: 1/4"=1'-0"
A
A4
2'-0"X8'-0"
TABBY FINISH
FIREPLACE
@ EAVE
GUTTER
BRICK PORCH
32'-4"
14'-0"
4'-0" 4'-0" 4'-0" 4'-0" 3'-11" 7'-41
2" 7'-4 1/2" 3'-11" +/-20'-0"
7'-73
4" 7'-1/2" 7'-73
4"
19'-0" 22'-7" +/-20'-0"
+/-73'-4"
+/-9'-8"
+/-17'-10" +/-13'-6" 2'-9" 8'-10" 2'-5" 10'-8" 2'-3" 3'-5" 2'-0"
+/-42'-1"
CLCLCLCL
CLCL
+/-9'-8"
CL CL CL
3'-0" 16'-0" 22'-7" +/-20'-0"
3'-0" 8'-0" 8'-0" 4'-13
4" 4'-13
4" 6'-0" 4'-13
4" 4'-13
4"CL CLCL
+/-20'-0"
1
DP35
2
DP35
2
DP35
D
DP35
D
DP35
A
DP35
A
DP35
C
DP45
C
DP35
C
DP45
B
DP45
B
DP45
B
DP45
A
DP35
A
DP35
Wood Floor Wood Floor
2'-10" 16'-6" 18" 4'-4" 2'-10"
E
DP45
E
DP45
E
DP45
SH.8'-2" 6'-8" 4'-0" 4'-3" 18" 11'-51
2" 18" 4'-01
2"
14'-0" 3'-10" 3'-10" 2'-8"
22'-4"'3'-0" 3'-0"
6'-0"
ATTACHMENT 4
A5
PROPOSED ROOF PLAN
2/5/21
DATE :
SHEET
MANUEL
STUDIO, LLC
BLUFFTON, SC
100072
ANSLEY HESTER
MANUEL
BLUFFTON, SC
6887
ANILORACHTUOSFOETATS
REGISTERED ARCHITECT
ANILORACHTUOSFOETATS
REGISTERED ARCHITECTS
MANUEL STUDIO, LLC
Ansley Hester Manuel, Architect
104 Pritchard Street, Bluffton, South Carolina 29910
843.338.8932 cell manuel.studio@aol.com
ADDITIONS TO
THE BROWN RESIDENCE
38 LAWRENCE ST. BLUFFTON SOUTH CAROLINA 29910
6:12 SLOPE 6:12 SLOPE 3:12 SHED
RIDGE
6:12 GABLE 6:12 GABLE
3:12
SHED
24"
26"
26"
12"
12"
26"
26"
26"
12"
@ LIVING
GUTTER
EX. 6:12 GABLE EX. 6:12 GABLE
3:12
SHED
EX.
RIDGE
RIDGE
PROPOSED ROOF PLAN
SCALE: 1/4"=1'-0"
A
A5
ATTACHMENT 4
A6
EXISTING ELEVATIONS
2/5/21
DATE :
SHEET
MANUEL
STUDIO, LLC
BLUFFTON, SC
100072
ANSLEY HESTER
MANUEL
BLUFFTON, SC
6887
ANILORACHTUOSFOETATS
REGISTERED ARCHITECT
ANILORACHTUOSFOETATS
REGISTERED ARCHITECTS
MANUEL STUDIO, LLC
Ansley Hester Manuel, Architect
104 Pritchard Street, Bluffton, South Carolina 29910
843.338.8932 cell manuel.studio@aol.com
ADDITIONS TO
THE BROWN RESIDENCE
38 LAWRENCE ST. BLUFFTON SOUTH CAROLINA 29910
123
12 6
12 3
12 3
12 6
123
EXISTING FRONT ELEVATION
SCALE: 1/4"=1'-0"
A
A6
EXISTING EAST ELEVATION
SCALE: 1/4"=1'-0"
B
A6
EXISTING REAR ELEVATION
SCALE: 1/4"=1'-0"
C
A6
EXISTING WEST ELEVATION
SCALE: 1/4"=1'-0"
D
A6
ATTACHMENT 4
A7
PROPOSED ELEVATIONS
2/5/21
DATE :
SHEET
MANUEL
STUDIO, LLC
BLUFFTON, SC
100072
ANSLEY HESTER
MANUEL
BLUFFTON, SC
6887
ANILORACHTUOSFOETATS
REGISTERED ARCHITECT
ANILORACHTUOSFOETATS
REGISTERED ARCHITECTS
MANUEL STUDIO, LLC
Ansley Hester Manuel, Architect
104 Pritchard Street, Bluffton, South Carolina 29910
843.338.8932 cell manuel.studio@aol.com
ADDITIONS TO
THE BROWN RESIDENCE
38 LAWRENCE ST. BLUFFTON SOUTH CAROLINA 29910
EXISTINGNEW ADDITION
12
6
12
6
TOP OF SLAB
WINDOW HEAD
6'-8"
TOP OF PLATE
12'-0"VARIESGRADE
TABBY CHIMNEY
1" STANDING
SEAM ROOF
OUTLINE OF LIVING ROOM BEYOND
BRICK LANDING
DOUBLE HUNG WINDOWS
WINDOW HEAD
8'-8"
CEMENT BOARD RANDOM
WIDTH STAGGERED EDGE
SHINGLES
PROPOSED FRONT ELEVATION
SCALE: 1/4"=1'-0"
A
A7
PROPOSED EAST ELEVATION
SCALE: 1/4"=1'-0"
B
A7
8'-0"
HEADER
TOP OF SLAB
NUMBER ONE OYSTER
SHELL STUCCO
ATTACHMENT 4
A8
PROPOSED ELEVATIONS
2/5/21
DATE :
SHEET
MANUEL
STUDIO, LLC
BLUFFTON, SC
100072
ANSLEY HESTER
MANUEL
BLUFFTON, SC
6887
ANILORACHTUOSFOETATS
REGISTERED ARCHITECT
ANILORACHTUOSFOETATS
REGISTERED ARCHITECTS
MANUEL STUDIO, LLC
Ansley Hester Manuel, Architect
104 Pritchard Street, Bluffton, South Carolina 29910
843.338.8932 cell manuel.studio@aol.com
ADDITIONS TO
THE BROWN RESIDENCE
38 LAWRENCE ST. BLUFFTON SOUTH CAROLINA 29910
EXISTING NEW ADDITION
12
6
12
6
TOP OF SLAB
TABBY CHIMNEY
BRICK LANDING
DOUBLE HUNG WINDOWS
HEADER
8'-0"
PROPOSED REAR ELEVATION
SCALE: 1/4"=1'-0"
A
A8
TOP OF PLATE
12'-0"
TOP OF SLAB
VARIES
GRADE
8'-0"
TOP OF SLAB
HEADER
1" STANDING
SEAM ROOF
CEMENT BOARD RANDOM
WIDTH STAGGERED EDGE
SHINGLES
NUMBER ONE OYSTER
SHELL STUCCO
ATTACHMENT 4
A9
WALL & PORCH SECTIONS
2/5/21
DATE :
SHEET
MANUEL
STUDIO, LLC
BLUFFTON, SC
100072
ANSLEY HESTER
MANUEL
BLUFFTON, SC
6887
ANILORACHTUOSFOETATS
REGISTERED ARCHITECT
ANILORACHTUOSFOETATS
REGISTERED ARCHITECTS
MANUEL STUDIO, LLC
Ansley Hester Manuel, Architect
104 Pritchard Street, Bluffton, South Carolina 29910
843.338.8932 cell manuel.studio@aol.com
ADDITIONS TO
THE BROWN RESIDENCE
38 LAWRENCE ST. BLUFFTON SOUTH CAROLINA 29910
TYP. WALL SECTION
SCALE: 1"=1'-0"
A
A9
26" OVERHANG
12
6
62
62
62
62
62
2
8
VARIES 12'-0"
12"
24"
FRONT PORCH AND FOYER SECTION
SCALE: 1"=1'-0"
B
A9
24"
12"
13"
1" STANDING SEAM ROOF OVER
30# FELT OVER 1/2" CDX
PLYWOOD
SIMPSON MTS-20 @ EA. RAFTER
1X4
2X8 RAFTERS @ 16" O.C
METAL DRIP
2X8 BOX BEAM W/ 1X WRAP
1X2 COLUMN CAP
P.T. 8X8 COX HOLLOW CORE
COLUMN W/ CONTINUOUS TIE
ROD FROM SLAB EMBEDMENT
TO PLATE
P.T. 2X BEVELED BASE
COLUMN BASE STAND
24" OVERHANG
TURNED DOWN
CONCRETE FOOTING
W/ (3) #5 REBAR
CLEAN COMPACT AND
TREATED SOIL
BRICK ROWLOCK EDGE
BRICK OVER MORTAR BED OVER CONCRETE
SLAB WITH 6X6 W1.4 X W1.4 WWF OVER 6
MIL VAPOR BARRIER, DOUBLE 3' FROM EDGE
PITCH SOIL
PITCH SLAB
12
3
TOP OF PLATE
TOP OF SLAB
GRADE
62
62
62
62
62
8" CMU STEM WALL WITH (2) #5
VERTICAL REBAR @ 32" O.C. &
CORNERS, NUMBER ONE OYSTER
STUCCO FINISH
"L" BLOCK @ TOP COURSE
WITH (1) #5 REBAR
CONCRETE FOOTING WITH (3)
#5'S REBAR
CLEAN, COMPACT AND
TREATED SOIL
CONCRETE SLAB WITH 6X6 W1.4 X W1.4
WWF OVER 6 MIL VAPOR BARRIER, DOUBLE 3'
FROM EDGE
CEMENT BOARD RANDOM
WIDTH STAGGERED EDGE
SHINGLES OVER
HOUSEWRAP OVER 1
2" CDX
PLYWOOD SHEATHING
CONTINUOUS TIE ROD
FROM PIER EMBEDMENT
TO PLATE @ ALL
CORNERS, OPENINGS &
6'-0" O.C.
2X6 BLOCKING @
PLYWOOD SEAMS, FULL
48" TOP & BOTTOM
2X6'S @ 16" O.C. STUD WALL WITH R-13
INSUL. (OPT. OPEN CELL SPRAY FOAM)
P.T. 2X6 SILL
1
2" SHEETROCK @ WALLS
1X10
2
8
SIMPSON MTS-20 @ EA. RAFTER
2X8'S RAFTER @ 16" O.C. W/
R-30 OPEN CELL SPRAY FOAM
10'-0"
TOP OF PLATE
TOP OF SLAB
1" STANDING SEAM ROOF OVER
30# FELT OVER 1
2" CDX
PLYWOOD
2"
1/2" SHEETROCK ON 2X8'S @
16'-0" O.C. CEILING JOIST
8" CMU STEM WALL WITH (2) #5
VERTICAL REBAR @ 32" O.C. &
CORNERS.
"L" BLOCK @ TOP COURSE
WITH (1) #5 REBAR
CONCRETE FOOTING WITH (3)
#5'S REBAR
CLEAN, COMPACT AND
TREATED SOIL
CONCRETE SLAB WITH 6X6 W1.4 X W1.4
WWF OVER 6 MIL VAPOR BARRIER, DOUBLE 3'
FROM EDGE
CEMENT BOARD RANDOM
WIDTH STAGGERED EDGE
SHINGLES OVER
HOUSEWRAP OVER 1
2" CDX
PLYWOOD SHEATHING
CONTINUOUS TIE ROD
FROM PIER EMBEDMENT
TO PLATE @ ALL
CORNERS, OPENINGS &
6'-0" O.C.
2X6 BLOCKING @
PLYWOOD SEAMS, FULL
48" TOP & BOTTOM
2X6'S @ 16" O.C. STUD WALL WITH R-13
INSUL. (OPT. OPEN CELL SPRAY FOAM)
P.T. 2X6 SILL PLATE
1
2" SHEETROCK @ WALLS
1/2" SHEETROCK ON 2X8'S @
16'-0" O.C. CEILING JOIST
SIMPSON MTS-20 @ EA. RAFTER
2X8'S RAFTER @ 16" O.C. W/
R-30 OPEN CELL SPRAY FOAM
BRICK FINISH WITH TIE
EVERY THIRD COURSE
2
8
2
8
3/8" SMOOTH PLYWOOD SOFFIT
W/ VENTILATION
HARDIE PANEL PORCH CEILING
3/8" SMOOTH PLYWOOD SOFFIT W/
VENTILATION STRIP
PITCH SOIL
1X4
METAL DRIP
1X10
2
8
2"
8" 14"
22"
ATTACHMENT 4
A10
DETAILS, SECTIONS & SCHEDULES
2/5/21
CEMENT BOARD
RANDOM WIDTH
STAGGERED EDGE
SHINGLES OVER
HOUSEWRAP OVER 1/2"
CDX PLYWOOD
51
2"
51
2"
1/2" SHEETROCK
DOOR # WIDTH & HEIGHT STYLE REMARKS
1 3'-0" X 8'-0" FULL GLASS OUTSWING, 1'-2"X8'-0" SIDELITES
WINDOW WIDTH & HEIGHT STYLE REMARKS
A 3'-0" X 5'-0" DBLHUNG
C 2'-4" X 5'-0"
LITES
ALL DOORS ARE WOOD INTERIOR AND CLAD EXTERIOR.
CONSULT WITH OWNER ON FRONT DOOR (DOOR #1).
ALL GLASS TO BE IMPACT RESISTANT.
ALL WINDOWS ARE SIMULATED DIVIDED LITE WITH 7/8" MUNTINS.
ALL WINDOWS ARE WOOD INTERIOR AND VINYL CLAD EXTERIOR.
ALL GLASS TO BE IMPACT RESISTANT.
DP RATINGS ARE 35 IF MORE THAN 4' FROM CORNER & 45 IF WITHIN 4' FROM CORNER
LITES
4/4
4/4/2B 2'-0" X 4'-0" DBLHUNG
CORNER DETAIL
SCALE: 1"=1'-0"
D
A10
DATE :
SHEET
MANUEL
STUDIO, LLC
BLUFFTON, SC
100072
ANSLEY HESTER
MANUEL
BLUFFTON, SC
6887
ANILORACHTUOSFOETATS
REGISTERED ARCHITECT
ANILORACHTUOSFOETATS
REGISTERED ARCHITECTS
MANUEL STUDIO, LLC
Ansley Hester Manuel, Architect
104 Pritchard Street, Bluffton, South Carolina 29910
843.338.8932 cell manuel.studio@aol.com
ADDITIONS TO
THE BROWN RESIDENCE
38 LAWRENCE ST. BLUFFTON SOUTH CAROLINA 29910
WINDOW TRIM DETAIL
SCALE: 3"=1'-0"
C
A10
PEAL AND SEAL AROUND
OPENING
FLASHING @ DRIPCAP
2X DRIP CAP (CYPRESS)
5/4X4 CASE TRIM (CYPRESS)
6
EGRESS REQUIRED @ BEDROOM
2 6'-0" X 8'-0" FRENCH DBL OUTSWING 6
4/4DBLHUNG
5/4 X 6 CYPRESS
CORNER TRIM
TRANSOM 2'-0"X1'-6", TEMPERED
5/4X4 CASE TRIM (CYPRESS)
5/4X4 CASE TRIM (CYPRESS)
4" CONCRETE SLAB
WITH 6X6 W1.4 X
W1.4 WWF, DOUBLE
3' FROM EDGES,
OVER 6 MIL VAPOR
BARRIER
12"
(2) #5 REBAR
TYP. THICKENED SLAB
SCALE: 1"=1'-0"
A
A10
6"
DOOR SCHEDULE
WINDOW SCHEDULE
62
62
62
2
6
2
6
2
6
2
6
1/2" SHEETROCK
THICKENED SLAB @ COLUMN
SCALE: 1"=1'-0"
B
A10
D 3'-0" X 6'-0" DBLHUNG
E *2'-6" X 5'-0" DBLHUNG *MATCH EXISTING DINING WINDOW 4/4
2'-10"
6" 4"
4"
18"X18" INTERIOR
"COLUMN"
2X6'S FRAME
PACK STUDS @ BEAM
ABOVE
6262
ATTACHMENT 4
ATTACHMENT 5
ATTACHMENT 5
ATTACHMENT 5
ATTACHMENT 6
ATTACHMENT 6
ATTACHMENT 6
ATTACHMENT 6
ATTACHMENT 6
ATTACHMENT 6
ATTACHMENT 6
ATTACHMENT 6
ATTACHMENT 6
ATTACHMENT 6
PLAN REVIEW COMMENTS FOR COFA-12-20-014812
Town of Bluffton
Department of Growth Management
20 Bridge Street P.O. Box 386 Bluffton, South Carolina 29910
Telephone 843-706-4522
OLD TOWN
Plan Type: Apply Date:
Plan Status: Plan Address: 38 Lawrence St Street
BLUFFTON, SC 29910
Historic District
Active
12/07/2020
Plan PIN #:Case Manager: R610 039 00A 0253 0000Katie Peterson
Plan Description: A request by Ansley Manuel, on behalf of James Mitchell and Laurie Brown for review of a Certificate of
Appropriateness to an addition of approximately 2,580 SF to the existing single-family structure of
approximately 1.545 SF located at 38 Lawrence Street in the Old Town Bluffton Historic District and zoned
Neighborhood General-HD.
STATUS: The Application will be heard at the January 4, 2021 HPRC meeting.
Staff Review (HD)
Submission #: 1 Recieved: 12/08/2020 Completed: 01/02/2021
Reviewing Dept. Complete Date StatusReviewer
Approved with Conditions01/02/2021Growth Management Dept Review
(HD)
Katie Peterson
Comments:
1. Doors are permitted to be wood, metal or metal clad. The application lists the doors as to match existing, however, additional
information must be provided to ensure they will be a permitted material. (5.15.6.I.2.b.)
2. Windows are permitted to be Wood, Aluminum, Copper, Steel, Vinyl, Clad Wood, or Fiberglass. The application lists the windows
to match existing, however, additional information must be provided to ensure they will be a permitted material. (5.15.6.I.2.a.)
3. The first floor finish height must be 3 feet above the average adjacent sidewalk grade. Provide elevation of adjacent sidewalk
grade to confirm that the finished floor is 36" above grade. (UDO Section 5.15.5.F.1.c.)
4. Porches are required to have a minimum height of 30 inches minimum from the adjacent grade to the top of stairs. The height of
the porch must be increased to meet this requirement. (UDO Section 5.15.6.E.5.c.)
5. Missing west and rear elevations. As such, the review is not complete.
6. Building heights and widths shall be visually similar to those in the neighboring vicinity. As the addition to this structure is
substantial, additional information showing the scale of the proposed in relation to the neighboring properties must be provided.
(UDO 5.15.5.F.1.a.)
7. In no case shall parking be located in front of a building. The plan proposed reconfigures how the house is approached by
vehicle. The driveway must be reconfigured, or to allow parking to be located on the side or the rear of the structure. (UDO
5.15.7.D.1.)
Approved with Conditions01/02/2021HPRC Review Katie Peterson
Comments:
1. As the project moves toward Final submittal, provide a landscape plan noting foundation plantings, canopy coverage and street
trees, typical window detail, a railing detail, a corner board detail, and a section through the exterior wall and eave as not enough
information was provided in submittal to review these items for conformance with the UDO. (Applications Manual)
Approved01/02/2021Beaufort Jasper Water and Sewer
Review
James Clardy
Comments:
1. BJWSA provides no comments.
Approved01/02/2021Transportation Department Review
- HD
William Howard
Comments:
1. No comment.
Approved12/17/2020Addressing Review Nick Walton
01/02/2021 Page 1 of 2
ATTACHMENT 7
Comments:
1. Address will remain 38 Lawrence Street.
Approved12/10/2020Watershed Management Review William Baugher
Comments:
1. No comment.
Plan Review Case Notes:
01/02/2021 Page 2 of 2
ATTACHMENT 7
10 Marianna Way, Building 5 – Certificate of Appropriateness Historic Preservation Commission
HISTORIC PRESERVATION
COMMISSION
STAFF REPORT
Department of Growth Management
MEETING DATE: March 3, 2021
PROJECT: 10 Marianna Way
APPLICANT: Court Atkins Architects, Inc.
PROJECT MANAGER: Katie Peterson, AICP, Senior Planner
APPLICATION REQUEST: The Applicant, Court Atkins Architects, Inc., on behalf of
Herkus, LLC, requests that the Historic Preservation Commission approve the
following application:
1. COFA-01-21-014894. A Certificate of Appropriateness to allow the
construction of a new 2 1/2-story Mixed-Use building of approximately 5,272
heated square feet located at 10 Marianna Way, Building 5 in the Old Village
Square development, in the Old Town Bluffton Historic District and zoned
Neighborhood General – HD.
INTRODUCTION: The Applicant is proposing the construction of a mixed-use
structure located in the Old Town Bluffton Historic District. The proposed building,
of approximately 5,272 SF, does not meet any of the building types for the
Neighborhood General-HD zoning district, and therefore shall be reviewed as an
Additional Building Type in accordance with Section 5.15.5.C. of the Unified
Development Ordinance (UDO). This lot is located within the Old Village Square
development plan, which was last amended in April of 2019 (DPA-06-17-011010).
The main mass of the addition is under a two and a half-story side-facing gable
with hip roofed dormers on the front and rear. It features a full-length two-story
porch on the front elevation. The two sides have balconies supported by brackets,
accessed by the loft level units. The structure is sided in Horizontal Lap Siding. The
roofs are a combination of shingle and standing seam metal and operable shutters
have been proposed on all windows which can accept them.
This project was presented to the Historic Preservation Review Committee for
conceptual review at the January 20, 2021 meeting and comments were provided
to the Applicant (See Attachment 6).
HISTORIC PRESERVATION COMMISSION ACTIONS: As granted by the powers and
duties set forth in Section 2.2.6.E.2, the Historic Preservation Commission has the
authority to take the following actions with respect to this application:
1. Approve the application as submitted by the Applicant;
March 3, 2021 Page 2
10 Marianna Way, Building 5 – Certificate of Appropriateness Historic Preservation Commission
2. Approve the application with conditions; or
3. Deny the application as submitted by the Applicant.
It is important to note that the intent of Section 5.15 Old Town Bluffton Historic
District of the Unified Development Ordinance (UDO) is that the Section be user
friendly and informative to the residents and the members of HPC and is not
intended to discourage creativity or force the replication of historic models. Rather,
it is to set forth a framework in which the diversity that has always characterized
Bluffton can continue to grow. The Section also defines guidelines for design and
materials similar to that used on structures within the Old Town, and it is the
charge of the HPC to assess the interpretation of these guidelines as they pertain to
applications using the established review criteria.
REVIEW CRITERIA & ANALYSIS: Town Staff and the Historic Preservation
Commission are required to consider the criteria set forth in Section 3.18.3 of the
UDO in assessing an application for a Certificate of Appropriateness – Historic
District (HD). The applicable criteria are provided below followed by a Staff
Finding(s) based upon review of the application submittals to date.
1. Section 3.18.3.B. Consistency with the principles set forth in the Old Town
Master Plan.
a. Finding. The application is consistent with the principles set forth in the
Old Town Master Plan. The Old Town Master Plan states that, “The built
environment, in particular the historic structures scattered throughout Old
Town, should be protected and enhanced. While it is of great importance
to save and restore historic structures, it is just as important to add to the
built environment in a way that makes Old Town more complete.”
The Applicant proposes to construct a new Mixed-Use building within the
Old Town Bluffton Historic District, a locally and nationally designated
historic district. The building has been designed to be sympathetic to the
architectural character of the neighboring historic structures, so its
addition to the architectural diorama will both protect the integrity of the
existing historic structures and enhance the neighborhood by adding
architectural variety.
b. Finding. The Old Town Master Plan initiatives also include the adoption of
a form-based code that included architectural standards for structures
located within the Old Town Bluffton Historic District. These standards
are included in Article 5 of the UDO. The new construction proposed as
part of this request will be in conformance with those standards if the
conditions noted in item 2 of this Section are met.
c. Finding. The Old Town Master Plan initiatives also promote preservation
and protection of the legacy of the Old Town Bluffton Historic District
through additions to the built environment which make Old Town more
complete. The addition of the proposed structure will add to the district
as well as help provide completeness to the neighborhood and overall
district.
March 3, 2021 Page 3
10 Marianna Way, Building 5 – Certificate of Appropriateness Historic Preservation Commission
2. Section 3.18.3.C. The application must be in conformance with applicable
provisions provided in Article 5, Design Standards.
a. Finding. Town Staff finds that the design of the structure falls within the
category of Additional Building Type within the Neighborhood General
Historic District per Section 5.15.5.C. As the Commission with approval
authority in accordance with Article 2 of the UDO, the HPC has final
approval authority on the appropriateness of an Additional Building Type
within this zoning district. Town Staff requests the Historic Preservation
Commission review and make a final determination regarding the
appropriateness of the Additional Building Type.
b. Finding. The building location is in the Old Village Square Development
Planned area. As such, the setbacks for the structure are determined by
the approved Development Plan rather than by Article 5 of the UDO. The
setbacks, as proposed, are in compliance with the approved Development
Plan.
c. Finding. Town Staff finds that if the conditions noted below are met, the
proposed structures will be in conformance with applicable provisions
provided in Article 5:
1) Section 5.15.6.A. Architectural Standards. The standards
encourage Bluffton vernacular architecture and construction which
is straightforward and functional, and which draws its ornament
and variety from the traditional assembly of genuine materials.
The UDO Administrator shall have authority to approve substitute
materials for those listed as options under the Architectural
Standards. The rear elevation shows the use of what appears to
be two false windows or closed shutters. Additional information
regarding the windows is required. A determination on the
appropriateness of the use of a false window must be made by the
HPC. If it is a closed shutter, a detail must be provided and
traditional hardware, including hinges and shutter dogs, must be
provided.
2) The Floor Plans show partitions on the second-floor porch. The
Elevations and Wall Sections must be updated to show the
materials and configuration of the partitions, or the floor plans to
remove them. Additionally, the elevations show the use of
shingles on the main gable and standing seam metal on porches
and dormers. The wall sections do not show asphalt shingles and
must be updated to reflect the elevations.
3. Section 3.18.3.D. Consistency with the nature and character of the
surrounding area and consistency of the structure with the scale, form and
building proportions of the surrounding neighborhood.
March 3, 2021 Page 4
10 Marianna Way, Building 5 – Certificate of Appropriateness Historic Preservation Commission
Finding. Town Staff finds the nature and character of the new construction
to be consistent and harmonious with that of the surrounding neighborhood.
The mass and scale of the structure is appropriate for its location and the
architectural detailing, with revisions to address the items in section 2 above,
will be sensitive to the neighboring properties.
4. Section 3.18.3.F. The historic, architectural, and aesthetic features of the
structure including the extent to which its alteration or removal would be
detrimental to the public interest.
Finding. The Applicant seeks approval for the construction of a new structure
in the Old Town Bluffton Historic District. The proposed plans are
sympathetic in design to the neighboring historic and non-historic resources;
therefore, the structure, as proposed, will have no adverse effect on the
public interest.
5. Section 3.18.3.H. The application must comply with applicable requirements
in the Applications Manual.
Finding. The application has been reviewed by Town Staff and has been
determined to be incomplete, the revised application did not include the
signature of the Applicant or Owner and must be signed prior to approval.
Additionally, it should be noted that the review is only of page L501 of the
Landscape Plan, as this review is for Building 5 only. The Landscape Plan
associated with the Development Plan must still be implemented for the
areas outside the scope of work for this application.
STAFF RECOMMENDATION: It is the charge of the HPC to assess and interpret the
standards and guidelines set forth in the UDO as they pertain to applications using
the review criteria established in the UDO and to take appropriate action as granted
by the powers and duties set forth in Section 2.2.6.E.2. Town Staff finds that with
the conditions noted below, the requirements of Section 3.18.3 of the Unified
Development Ordinance have been met and recommends that the Historic
Preservation Commission approve the application including the architectural plan
set dated 2021.02.08, the Landscape Plan (Page L501 only) dated Feb 22, 2021
with the following conditions:
1. Per Section 5.15.6.A., the Applicant is requesting a determination on the
appropriateness of the use of two false windows on the rear elevation.
2. Additional information must be provided on the configuration of the false
windows on the rear elevation.
3. The Floor Plans or Elevations and Wall Section must be updated to reflect
the partitions on the second-floor porch.
4. The Elevations or Wall Sections must be revised to reflect the same
roofing material.
5. Per the Applications Manual, the Application must be signed by both the
Applicant and the Owner.
March 3, 2021 Page 5
10 Marianna Way, Building 5 – Certificate of Appropriateness Historic Preservation Commission
ATTACHMENTS:
1. Location Map
2. Zoning Map
3. Application & Applicant Narrative
4. Site Plan & Elevations
5. Landscape Plan
6. HPRC Report
10 Marianna Way - Location Map
2 / 5 / 2 0 2 1
0 0 . 0 3 0 . 0 5 0 . 0 8 0 . 1 0 . 1 30 . 0 1
m i
F
ATTACHMENT 1
10 Marianna Way - Zoning Map
2 / 5 / 2 0 2 1
0 0 . 0 3 0 . 0 5 0 . 0 8 0 . 1 0 . 1 30 . 0 1
m i
F
I n f o L a y e r
P a r c e l P r o p e r t y L in e s
ATTACHMENT 2
TOWN OF BLUFFTON
CERTIFICATE OF APPROPRIATENESS- OLD TOWN BLUFFTON
HISTORIC DISTRICT (HD) APPLICATION
Town of Bluffton Certificate of Appropriateness-Historic District Application Last Updated: 4/8/2014
Growth Management Customer Service Center
20 Bridge Street
Bluffton, SC 29910
(843)706-4522
www.townofbluffton.sc.gov
applicationfeedback@townofbluffton.com
Applicant Property Owner
Name: Name:
Phone: Phone:
Mailing Address: Mailing Address:
E-mail: E-mail:
Town Business License # (if applicable):
Project Information (tax map info available at http://www.townofbluffton.us/gis/)
Project Name: Conceptual: Final: Amendment:
Project Location: Application for:
New Construction
Renovation/Rehabilitation/Addition
Relocation or Demolition
Zoning District:
Acreage:
Tax Map Number(s):
Project Description:
Minimum Requirements for Submittal
1. Full sized copies and digital files of the Site Plan(s). One (1) set for Conceptual, two (2) sets for Final
2. Full sized copies and digital files of the Architectural Plan(s). One (1) set for Conceptual, two (2) sets for Final
3. Project Narrative describing reason for application and compliance with the criteri a in Article 3 of the UDO.
5. All information required on the attached Application Checklist.
6. An Application Review Fee as determined by the Town of Bluffton Master Fee Schedule. Checks made payable
to the Town of Bluffton.
Note: A Pre-Application Meeting is required prior to Application submittal.
Disclaimer: The Town of Bluffton assumes no legal or financial liability to the applicant or any
third party whatsoever by approving the plans associated with this permit.
I hereby acknowledge by my signature below that the foregoing application is complete and accurate and that I am
the owner of the subject property. As applicable, I authorize the subject property to be posted and inspected.
Property Owner Signature: Date:
Applicant Signature: Date:
For Office Use
Application Number: Date Received:
Received By: Date Approved:
ATTACHMENT 3
TOWN OF BLUFFTON
CERTIFICATE OF APPROPRIATENESS – HISTORIC DISTRICT
PROJECT ANALYSIS
Last Updated: 4/8/2014
In accordance with the Town of Bluffton Unified Development Ordinance (UDO), the following information shall
be included as part of a Certificate of Appropriateness application submitted for review by the Historic
Preservation Commission (HPC) and the Historic Preservation Review Committee . The use of this checklist by
Town Staff or the Applicant shall not constitute a waiver of any requirement contained in the UDO.
1. DESIGN REVIEW PHASE CONCEPTUAL REVIEW FINAL REVIEW
2. SITE DATA
Identification of Proposed Building Type (as defined in Article 5):
Building Setbacks Front: Rear: Rt. Side: Lt. Side:
3. BUILDING DATA
Building
Description
(Main House, Garage, Carriage
House, etc.)
Existing Square
Footage
Proposed Square
Footage
Main Structure
Ancillary
Ancillary
4. SITE COVERAGE
Impervious Coverage Coverage (SF)
Building Footprint(s)
Impervious Drive, Walks & Paths
Open/Covered Patios
A.TOTAL IMPERVIOUS COVERAGE
B.TOTAL SF OF LOT
% COVERAGE OF LOT (A/B= %)
5. BUILDING MATERIALS
Building Element Materials, Dimensions,
and Operation Building Element Materials, Dimensions,
and Operation
Foundation Columns
Walls Windows
Roof Doors
Chimney Shutters
Trim Skirting/Underpinning
Water table Cornice, Soffit, Frieze
Corner board Gutters
Railings Garage Doors
Balusters
Green/Recycled Materials
Handrails
ATTACHMENT 3
January 20, 2021
Katie Peterson, Senior Planner
Town of Bluffton
Growth Management
Bluffton, SC 29910
Project: Building 5 at Old Village Square
Re: HPC submittal
Katie,
Please find the documents enclosed for the HPC to consider an alternate building design for Building #5 at the Old
Village Square development. Due to design and construction constraints outside the control of the Owner, we
were engaged to re-design the exterior envelope, while maintaining or reducing the previously approved square
footage, width, length, and height. As discussed, the building will be maintained as an “Additional Building” type
and reviewed as such. Please note, the approved development plan is a horizontal regime and thus, the site
approvals and characteristics/parameters are unique (i.e. setbacks) to this project.
Based upon the HPRC review and staff comments; the design drawings have been modified. Please see the specific
comment responses below:
Growth Management
1) The first floor of each building has been redesigned to accommodate a rentable commercial office space
in order to qualify as a mixed-use building type.
2) Notices will be sent once the Town provides the list of adjacent property owners.
3) An updated application has been provided.
4) The building is submitted as an “additional building type” and to be reviewed as such.
5) The center gable on the porch was maintained as previously submitted based upon the HPRC discussion.
The rear gable has been maintained as well due to head height requirements in the stair. The rear
elevation has ample glazing and fenestration.
6) This building is a mixed-use (residential and commercial) structure noted as an “additional building type.”
7) The side porches have been removed. A balcony was added on the third floor.
8) The side porches have been removed.
9) The side porches have been removed. Services yard have been added on the sides.
10) The fiberglass doors have been changed to metal-clad.
11) The clipped gable has been removed.
12) The roof material has been changed to all fiberglass shingle except at the dormers and porch.
13) While the originally approved development has 4 nearly identical buildings, modifications will be made to
10 Marianna Way to create visual distinction from Building #4.
14) Details had been provided.
Building Safety Review
1) Acknowledged.
HPRC Review
1) Service yards are located on the side and rear of the building .
2) See calculations showing 70% or less for the ½ story area calculation. Calculations have been updated.
ATTACHMENT 3
2
Kind Regards,
James Atkins, Architect
ATTACHMENT 3
NOTE TO GENERAL CONTRACTORS: THESE DRAWINGS HAVE BE EN PRODUCED
UNDER A LIMITED SERVICES AGREEMENT BETWEEN THE OWNE R/OWNER'S
REPRESENTATION AND COURT ATKINS ARCHITECTS, INC. THEY ARE TO BE USED FOR
DESIGN INTENT AND IN COORDINATION WITH SUPPLEMENT E NGINEERING
DOCUMENTS.
THE ARCHITECT'S DRAWINGS CANNOT STAND ALONE AS CONSTRUCTION
DOCUMENTS.
SEE STRUCTURAL ENGINEERING DOCUMENTS FOR STRUCTURAL CONNECTION
TECHNIQUES, CALCULATIONS REQUIRED BY CODE, CODE COMPLIANCE
INSTRUCTIONS FOR WALL AND ROOF CONSTRUCTION, AND TI E DOWN
REQUIREMENTS.
SEPARATE MECHANICAL, ELECTRICAL, AND PLUMBING ENGINEERING DOCUMENTS
MAY BE PROVIDED, WHICH INDICATE REQUIRED SERVICE AN D RISER DIAGRAMS,
CALCULATIONS AND INSTALLATION SPECIFICATIONS BEYOND THE ARCHITECTS
BASIC LAYOUT AND SELECTIONS SUGGESTIONS.
SEPARATE CIVIL ENGINEERING DOCUMENTS MAY BE PROVIDE D, WHICH INDICATE
ADDITIONAL SITE PLANNING, DRAINAGE, AND OTHER RELATED SITE WORK
REQUIREMENTS.
SELECTIONS NOT INCLUDED IN THESE DOCUMENTS WILL BE COORDINATED BY THE
OWNER/ OWNER'S REPRESENTATIVES.
BY APPLYING FOR A BUILDING PERMIT AND/OR CONSTRUCTI NG THE PROJECT
REPRESENTED HEREIN, THE OWNER AGREES TO LIMIT THE L IABILITY OF THE
ARCHITECT TO THE OWNER OF THE PROJECT FOR ALL AND ANY CLAIMS, LOSSES,
DAMAGES OR ANY NATURE WHATSOEVER, OR CLAIMS OF EXPE NSES FOR ANY
SUCH ITEMS TO THE ARCHITECTS TOTAL COMPENSATION FOR SERVICES RENDERED
HEREIN.
THESE DOCUMENTS ARE THE WORK INSTRUMENTS OF THE ARCHITECT AND HAVE
BEEN PREPARED SPECIFICALLY AND SOLELY FOR THE PROJECT NAMED HEREIN. THEY
ARE NOT SUITABLE FOR USE ON OTHER PROJECTS OR IN OTHER LOCATIONS WITHOUT
THE PARTICIPATION OF THE ARCHITECT. REPRODUCTION IS STRICTLY PROHIBITED. THE
ARCHITECT SHALL BE DEEMED THE AUTHOR AND OWNER OF THESE DOCUMENTS
AND SHALL RETAIN COMMON LAW, STATUTORY AND OTHER RESERVED RIGHTS,
INCLUDING THE COPYRIGHT.
THE ARCHITECT HAS NOT BEEN CONTRACTED TO PERFORM CONSTRUCTION
ADMINISTRATION/ ON-SITE OBSERVATION FOR THIS PROJEC T.
FOR DIMENSIONS NOT SHOWN OR IN QUESTION, THE CONTRA CTOR WILL REQUEST
CLARIFICATION FROM THE ARCHITECT BEFORE PROCEEDING.
CONTRACTOR WILL VERIFY ALL EXISTING CONDITIONS IN T HE FIELD- ANY
DISCREPANCIES WILL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT.
THE CONTRACTOR SHALL MAINTAIN AT THE SITE OF THE WORK, A SET OF RECORD
DRAWINGS. THE CONTRACTOR SHALL RECORD ALL CHANGES AND DEVIATIONS
FROM THE DRAWINGS ON THIS "AS-BUILT" SET, WHICH SHA LL BE UPDATED AT LEAST
EVERY OTHER WEEK. AT THE CLOSE OF THE JOB, THE CONTRACTOR SHALL PROVIDE
ONE COMPLETE SET OF ALL AS-BUILT INFORMATION TO THE ARCHITECT IN CLEAR
AND LEGIBLE FORMAT.
SIGNS SHALL BE LIMITED TO THE PROJECT IDENTIFICATIO N SIGN. THE IDENTIFICATION
SIGN SHALL IDENTIFY THE PROJECT, THE ARCHITECT AND THE CONTRACTOR.
INFORMATION CONTAINED ON THESE DRAWINGS IS PROVIDED FOR THE
CONVENIENCE OF THE GENERAL CONTRACTOR IN EXECUTING THE WORK. EVERY
ATTEMPT HAS BEEN MADE TO PROVIDE COMPLETE AND ACCURATE
REPRESENTATIONS OF SUCH CONDITIONS.
WHEN ARCHITECTURAL DRAWINGS ARE IN CONFLICT WITH EN GINEERING
DRAWINGS THE GENERAL CONTRACTOR SHALL REQUEST CLARIFICATION FROM THE
ARCHITECT BEFORE PROCEEDING.
GENERAL NOTES
THIS WRITTEN NOTICE REQUIRED BY SOUTH CAROLINA REGU LATIONS TO THE
PERMITTING AUTHORITY AND BUILDING OWNER THAT THE AR CHITECTS WILLIAM
COURT AND JAMES ATKINS HAVE NOT BEEN HIRED TO PROVIDE MINIMUM
CONSTRUCTION ADMINISTRATION SERVICES ON THE FOLLOWI NG PROJECT.
RESIDENTIAL (R) & BUSINESS (B) MIXED USE OCCUPANCY:
REGULATION 11-12.B.4 AND 5 STATE:
(1) ON A PROJECT WHERE A BUILDING PERMIT HAS BEEN ISSUED AND THE SEALING
ARCHITECT AND THE FIRM OF RECORD HAVE NOT BEEN ENGAGED TO PERFORM AT
LEAST MINIMUM CONSTRUCTION ADMINISTRATION SERVICES, AS DEFINED IN
SUBSECTION (5) BELOW, THE SEALING ARCHITECT AND FIRM MUST REPORT TO THE
PERMITTING AUTHORITY AND THE BUILDING OWNER THAT HE AND THE FIRM HAVE
NOT BEEN SO ENGAGED.
(2) THE MINIMUM CONSTRUCTION ADMINISTRATION SERVICE S EXPECTED OF THE
SEALING ARCHITECT AND FIRM DEEMED NECESSARY TO PROTECT THE HEALTH,
SAFETY, AND WELFARE OF THE PUBLIC SHALL BE PERIODIC SITE OBSERVATIONS OF
THE CONSTRUCTION PROGRESS AND QUALITY, REVIEW OF CONTRACTOR SUBMITTAL
DATA AND DRAWINGS, AND REPORTING TO THE BUILDING OFFICIAL AND OWNER
ANY VIOLATIONS OF CODES OR SUBSTANTIAL DEVIATIONS F ROM THE CONTRACT
DOCUMENTS WHICH THE ARCHITECT OBSERVED.
CONSTRUCTION ADMINISTRATION
OCCUPANCY CLASSIFICATION: RESIDENTIAL (R-2) & BUINESS (B)
MIXED OCCUPANCY: YES X NO SEPARATION 0 HR.
CONSTRUCTION TYPE: I-A I-B II-A II-B
III-A III-B IV V-A V-B
MIXED CONSTRUCTION: YES NO X TYPE
SPRINKLERED: YES X NO
FIRE DISTRICT: YES _______ NO X
BUILDING HEIGHT: 37' - 8" AFF NUMBER OF STORIES: 2 1/2
MEZZANINE: YES _______ NO X
HIGH RISE: YES _______ NO X
BUILDING DATA
PROJECT DESCRIPTION:
CONSTRUCTION OF A 2 1/2 STORY MULTI-FAMILY / OFFICE BUILDING
BUILDING CONSTRUCTION:
LOAD BEARING WOOD STUDS, WOOD ROOF TRUSSES & CONCRETE SLAB ON GRADE.
CATAGORY ALLOWABLE AC TUAL
HEIGHT (RES.): 40'-0" 37'-8"
STORIES(RES.): 3 ST. 2 1/2 ST.
AREA PER FLOOR: 9,000 SF 2,604 SF
AREA TOTAL: 18,000 SF 7,197 SF
AREA INCREASE? Yes _______ No X
HEIGHT INCREASE? Yes _______ No X
RESIDENTIAL (R): 5,092 SF / 200 SQ.F.T (GROSS) PER PERSON = 26
TOTAL (R) OCCUPANCY: 26 OCCUPANTS
BUSINESS (B): 180 SF / 150 SQ.F.T (GROSS) PER PERSON = 2
TOTAL (R) OCCUPANCY: 2 OCCUPANTS
TOTAL OCCUPANCY ON SITE: 37 OCCUPANTS
NUMBER OF EXITS: REQUIRED PROVIDED
2 2
EXIT ACCESS DESIGN REQUIREMENTS, PER MOST RESTRICTIVE
CATAGORY MAX. ALLOWABLE ACTUAL MAX
EXIT ACCESS TRAVEL DISTANCE
(IBC TABLE 1017.2) : 250 FT (R-2) & 300 FT (B) XXX FT (R-2) & XXX FT (B)
COMMON PATH OF TRAVEL
(IBC TABLE 1006.2.1) 125 FT (R-2) & 100 FT (B) XXX FT (R-2) & XXX FT (B)
DEAD END CORRIDOR
(IBC TABLE 1020.4) 20 FT XX FT
ALLOWABLE HEIGHT & AREA (PER IBC TABLE 504.3 & 504.4 & 506.2):
OCCUPANT LOAD (IBC TABLE 1004.5):
EXITS (IBC TABLE 1006.3.2)
TRAVEL DISTANCE
MINIMUM REQUIRED PLUMBING FIXTURES: PER IBC TABLE 2902.1
FIRE SEPARATION
IBC TABLE 601, 602, 508.3.3 REQ'D HR DETAIL # % WALL OPENING UL RATED ASSEMBLY
PRIMARY STRUCTURAL FRAME
BEARING WALLS:
EXTERIOR
INTERIOR
ALL INTERIOR WALLS AND CEILING FINISHES TO COMPLY WITH IBC-2018, TABLE 803.13
IBC TABLE 803.13
GROUP
SPRINKLERED UNSPRINKLERED
VERT. EXITS /
EXIT PASSAGE-
WAYS
EXIT ACCESS
CORRIDORS /
OTHER EXITS
ROOMS &
ENCLOSED
SPACES
VERT. EXITS /
EXIT PASSAGE-
WAYS
EXIT ACCESS
CORRIDORS /
OTHER EXITS
ROOMS &
ENCLOSED
SPACES
RESIDENTIAL (R-2)
TOTAL OCCUPANCY FOR RESIDENTIAL (R-2) = X PERSONS
TOTAL OCCUPANCY FOR RESIDENTIAL (B) = X PERSONS
OCCUPANCY, 50% MALE / 50% FEMALE
XX MALE OCCUPANTS & XX FEMALE OCCUPANTS (R-2)
XX MALE OCCUPANTS & XX FEMALE OCCUPANTS (B)
PLUMBING CALCULATIONS
0
PROJECT INFORMATION
OWNER CONTACT
MR. HOUSSAM ABOUKHATER
10 ANSON PARK ROAD E
BLUFFTON, SC, 29910
(603) 205-5555 PH
STRUCTURAL ENGINEER
TBD
MECHANICAL, PLUMBING & FIRE
PROTECTION
TBD
ELECTRICAL ENGINEER
TBD
PROJECT TEAM
ARCHITECT
COURT ATKINS ARCHITECTS, INC.
32 BRUIN ROAD
P.O. BOX 3978
BLUFFTON, SC 29910
(843) 815-2557 PH
(843) 815-2547 FAX
GENERAL CONTRACTOR
TBD
LANDSCAPE ARCHITECT
TBD
CIVIL ENGINEER
TBD
DISCIPLINE NAME LICENSE NO. TELEPHONE NO.
ARCHITECTURAL JAMES C. ATKINS SC #6743 (843) 815-25 57
STRUCTURAL TBD -- (XXX) XXX-XXXX
ELECTRICAL TBD -- (XXX) XXX-XXXX
PLUMBING TBD -- (XXX) XXX-XXXX
MECHANICAL TBD -- (XXX) XXX-XXXX
CIVIL TBD -- (XXX) XXX-XXXX
LANDSCAPE TBD -- (XXX) XXX-XXXX
DESIGNER OF RECORD
TOTAL GROSS AREA (H/C): 5,272 SF (H/C)
GROSS BUILDING AREA
LEVEL 01: HEATED & COOLED 1,984 SF
LEVEL 02: HEATED & COOLED 1,984 SF
LOFT LEVEL: HEATED & COOLED 1,304 SF
NAME OF PROJECT: OLD VILLAGE SQUARE - BUILDINGS
ADDRESS: 10 MARIANNA WAY
BLUFFTON, SC 29910
PROPOSED USE: RESIDENTIAL (R-2) & BUSINESS (B)
OWNER CONTACT: MR. HOUSSAM ABOUKHATER
CODE ENFORCEMENT JURISDICTION: TOWN OF BLUFFTON
INTERNATIONAL BUILDING CODE (IBC): 2018
INTERNATIONAL MECHANICAL CODE: 2018
INTERNATIONAL PLUMBING CODE: 2018
THE NATIONAL ELECTRICAL CODE: 2017
INTERNATIONAL FUEL GAS CODE: 2018
INTERNATIONAL FIRE CODE: 2018
INTERNATIONAL ENERGY CONSERV. CODE: 2009
ICC/ANSI A117.1: 2017
INTERNATIONAL RESIDENTIAL CODE 2018
0
0
NON-BEARING WALLS:
EXTERIOR
INTERIOR
0
0
FIRE SEPARATION WALLS:
EXTERIOR
INTERIOR
FLOOR CONSTRUCTION 0
ROOF CONSTRUCTION 0
SHEET INDEX
HEYWARD ST.
SC HW
Y 46
PROJECT LOCATION
VICINITY MAP - N.T.S.
NORTH
W
S
E
COLUMN GRID
REFERENCE
A
ROOM
150 SF
Comments ROOM TAG
LEVEL 1
100' - 0"
LEVEL/ELEVATION
REFERENCE
EXTERIOR ELEV. SYMBOLA3.0
1
INTERIOR ELEVATION
SYMBOL
A7.0
1
A4.0
1 BUILDING SECTION
A5.0
1 WALL SECTION
A5.0
1 DETAIL SECTION
CALLOUT
A5.0
1
ENLARGED PLAN/
DETAIL CALLOUT
1
REVISION CLOUD
& TAG
WINDOW TAG DOOR TAG101.1
SYMBOL KEY
H
0
0
SCHULTS ST.
GOETHE RD.
PROMENADE ST.
B LUFFTON RD.
BOUNDRY ST.
CALHOUN ST.
DUBOIS LN.
WHARF ST.
BUSINESS (B)
C C C B B C
B C C A B C
REQUIRED FIXTURE RATIO REQUIRED FIXTURES FIXTURES PROVIDED
ITEM MEN WOMEN MEN WOMEN MEN WOMEN UNISEX
TOTAL WATER
CLOSETS
TOTAL
LAVATORIES
DRINKING
FOUNTAINS
OTHER
NOT REQUIRED (R-2)
1 PER 100 (B)
1 KITCHEN SINK PER DWELLING UNT;
1 AUTOMATIC CLOTHES WASHER CONNECTION PER
DWELLING UNIT
1 (R-2) &
1 (B) 1 (B)
1 PER DWELLING UNIT (R-2)
& 1 PER 25 FOR THE FIRST
50 & 1 PER 50 FOR THE
REMAINDER EXCEEDING
50 (B)
1 (B)
1 KITCHEN SINK PER DWELLING UNT;
1 AUTOMATIC CLOTHES WASHER
CONNECTION PER DWELLING UNIT
NOT REQUIRED (R-2)
1 FIXTURE (B)
1 (R-2) &
1 (B)
1 (R-2) &
1 (B)
1 PER DWELLING UNIT (R-2)
& 1 PER 40 FOR THE FIRST
80 & 1 PER 80 FOR THE
REMAINDER EXCEEDING
80 (B)
1 (R-2) &
1 (B)
1 (R-2) &
1 (B)
1 (R-2) &
1 (B)
1 (R-2) &
1 (B)
1 (R-2) &
1 (B)
NOT REQUIRED (R-2)
1 FIXTURE (B)
BATH TUBS /
SHOWERS
1 PER DWELLING UNIT (R-2)
NOT REQUIRED (B)
1 FIXTURE (R-2)
NOT REQUIRED (B)
1 FIXTURE (R-2)
NOT REQUIRED (B)
I SSUE
P ROJECT INFO
S HEET TITLE
D ate
P roject No.
COPYRIGHT 2019 COURT ATKINS GROUP -
THIS DRAWING IS THE PROPERTY OF THE
ARCHITECT AND IS NOT TO BE REPRODUCED IN
WHOLE OR IN PART BY ANY MEANS OR METHOD
WITHOUT THE EXPRESS WRITTEN CONSENT OF THE
ARCHITECT. ANY UNAUTHORIZED
REPRODUCTION OR REUSE OF THESE
DOCUMENTS WILL RESULT IN LEGAL ACTION.
POST OFFICE BOX 3978
BLUFFTON, SC 29910
PH: 843.815.2557
FX: 843.815.2547
WWW.COURTATKINS.COM
©
2/8/2021 11:27:22 AM
2 021.02.08
2 0-0 95
A0.0 O LD VILLAGE SQUARE - B UILDING 5
1 0 MARIANNA WAY
B LUFFTON, SC 29910
FINAL HPC SUBMITTAL
OLD VILLAGE SQUARE - BUILDING 5
10 MARIANNA WAY
BLUFFTON, SC 29910
C OVER SHEET
NO. REV. DATE DESCRIPTION
ARCHITECTURAL
SHT. # SHEET NAME ISSUE DATE DRAWING SET
A0.0 COVER SHEET 02/08/2021 HPC
A1.0 SITE PLAN 02/08/2021 HPC
A2.1 FIRST FLOOR PLAN 02/08/2021 HPC
A2.2 SECOND FLOOR PLAN 02/08/2021 HPC
A2.3 LOFT LEVEL PLAN 02/08/2021 HPC
A2.4 ROOF PLAN 02/08/2021 HPC
A3.0 FRONT EXTERIOR ELEVATION 02/08/2021 HPC
A3.1 RIGHT SIDE EXTERIOR ELEVATION 02/08/2021 HPC
A3.2 REAR EXTERIOR ELEVATION 02/08/2021 HPC
A3.3 LEFT SIDE EXTERIOR ELEVATION 02/08/2021 HPC
A5.0 DETAILS 02/08/2021 HPC
A6.0 DOOR AND WINDOW SCHEDULE 02/08/2021 HPC
ATTACHMENT 4
EXISTING
BUILDING
2
WM
SL
23,429 sq. ft.
0.54 acres
PARCEL 746
REFERENCE PLAT
ASPHALT
IN
NAIL
N/F
DEVSU, LLC
N/F
SADIE BRUIN PATRICK
BLUE WATER INVESTMENT GROUP INC.
N/F
N/F
WILLIAM G. MARTINI
&
VERONICA L. MARTINI
PARCEL 1569
PARCEL 1585
JOHN P. TREADAWAY
N/F
PARCEL 1570
PARCEL 497
PARCEL 164B
PARCEL 161
SHULTS ROAD 40' R/W
IPF
1/2"
REBAR
1/2"
IPF
REBAR
IPF
1/2"
REBAR
IPF
1/2"
REBAR
IPF
1" PIPE
3"X3"
CMF
3"X3"
CMF
3"X3"
CMF
IPF
1" PIPE
DYH
WV
BUILDING
4
BUILDING
5
FUTURE
BLDG.
UP
MAY RIVER ROAD
SHULTS ROAD
N
UP
OLD VILLAGE SQUARE
FEBRUARY 8, 2021
© COPYRIGHT 2021 COURT ATKINS GROUP
1 SITE PLAN
SCALE 1/32" : 1'-0"
ATTACHMENT 4
UP
Washer DryerWasherDryer
Range
Range
Refrigerator
Refrigerator
A3.11
A3.0
1
A3.2
1
A3.3 1
BUSINESS
OFFICE
VESTIBULE 1
OFFICE BATH
BEDROOM 1
VESTIBULE 2BATHROOM 1
LAUNDRY
KITCHEN /
DINING &
LIVING
CLOSET 2
CLOSET 1
BEDROOM 1
VESTIBULE 2
BATHROOM 1
LAUNDRYBATHROOM 2
VESTIBULE 1
BEDROOM 2
KITCHEN /
DINING &
LIVING
CLOSET 2
CLOSET 1
ELEC. RM. FIRE RISER
OPEN AIR
VESTIBULE
OPEN AIR
PORCH
9' - 11 3/8" 14' - 0 5/8" 8' - 0" 8' - 0" 8' - 0" 14' - 0 5/8" 9' - 11 3/8"
5' - 1" 72' - 0" 5' - 1"
10' - 0 1/2" 31' - 0" 4' - 9 3/8" 2 5/8"
46' - 0 1/2"
2' - 0" 68' - 0" 2' - 0"
5' - 1" 72' - 0" 5' - 1"
10' - 0 1/2" 31' - 0" 4' - 9 3/8" 2 5/8"
SERVICE
YARD
SERVICE
YARD
7 1/2" 7' - 7 1/4" 1' - 10" 8' - 5 1/4" 1' - 10" 7' - 7 1/4" 1' - 10" 8' - 6" 1' - 10" 7' - 7 1/4" 1' - 10" 8' - 5 1/4" 1' - 10" 7' - 7 1/4" 7 1/2"
7 1/2" 9' - 0" 5" 2' - 10" 5' - 7 1/2" 7' - 0 1/2" 7' - 0 5/8" 5' - 7 3/8" 2' - 10"
7 1/2" 9' - 0" 5" 2' - 10" 5' - 7 1/2" 7' - 0 5/8" 7' - 0 5/8" 5' - 7 1/2" 2' - 10"
4' - 2 1/8" 5' - 9 1/4" 6' - 3 7/8" 1' - 10 1/4" 4' - 0" 4' - 0" 4' - 0" 4' - 0" 1' - 10 1/4" 6' - 4 1/2" 5' - 9 1/4" 4' - 2 1/8"
4' - 5 1/8" 9' - 10 1/8" 9' - 10 1/8" 5' - 10 5/8" 4' - 0" 4' - 0" 5' - 10 5/8" 9' - 10 1/8" 9' - 10 1/8" 4' - 5 1/8"
11' - 7 3/4" 2' - 4 3/4" 6' - 0 1/4" 11' - 5 3/4" 8' - 0" 11' - 5 3/4" 6' - 3 3/4" 2' - 4 3/4" 11' - 4 1/4"
4' - 9 3/4" 8' - 11 1/4"
11' - 3 3/4" 6' - 0 1/4" 13' - 9"
6' - 10 1/8" 3' - 6 1/8" 1' - 7 5/8" 6' - 1 3/4" 5' - 11 1/8" 5" 2' - 0" 3' - 7 1/4"
6' - 10 1/8" 3' - 6 1/8" 1' - 10 5/8" 5' - 10 3/4" 5' - 11 1/8" 5" 2' - 0" 3' - 7 1/4"
14' - 0 1/2" 6' - 0 1/4" 11' - 0 1/4"
9' - 2 3/4" 4' - 9 3/4"
11' - 11 7/8" 11' - 11 3/8"
12' - 2 7/8" 11' - 11 3/8"
A2.1
2
103
103A
103C
103D
103F
103G
103H
102
101
100
104
104A
104B
104C
104D
104H
104F
104G
104E
103E
A A A A
A
ACCDDA
A
A
OPEN AIR
PORCH
ENTRY
PORCH
3' - 5"
B
2
A5.0
3
A5.0
4
A5.0
1
A5.0
3
A5.0
103B
46' - 0 1/2"
A2.1
3
SEE COVER PAGE FOR NOTES AND LIMITATIONS TO ARCHITE CTURAL SCOPE
OF SERVICES.
GENERAL CONTRACTOR NOTE:
ADJUST TOP OF SLAB, WALL, AND ROOF BEARING PLATES AS REQUIRED FOR
CHANGES IN STRUCTURAL MEMBER SIZES OR EXISTING SITE CONDITIONS.
GC/OWNER TO COORDINATE ALL IN-SLAB ELECTRICAL AND PLUMBING
REQUIREMENTS WITH APPROPRIATE SUBCONTRACTOR TRADES PRIOR TO
PLACING SLAB.
DIMENSION NOTES:
DIMENSIONS ARE TO THE EDGE OF FOUNDATION AND FRAMING, U.O.N..
DO NOT SCALE DRAWINGS. CONTACT ARCHITECT WITH ANY DISCREPANCIES.
CABINET & EQUIPMENT NOTES:
CABINET LAYOUTS ARE PROVIDED FOR DESIGN CONFIGURATION ONLY. EXACT
LAYOUT AND PLACEMENT OF FIXTURES, APPLIANCES, CABINETS, AND
COUNTERTOPS ARE TO BE DETERMINED IN COORDINATION WITH OWNER AND
GENERAL CONTRACTOR.
FINISH NOTES:
FLOOR, WALL, CEILING, FINISHES AND INTERIOR TRIM ARE TO BE DETERMINED
BY THE GENERAL CONTRACTOR AND OWNER. GENERAL CONTRACTOR TO
ADJUST SLAB, WALLS, AND CEILING TO ACCOMMODATE OWNER SPECIFIC
FINISHES AND TRIM.
OR
FLOOR, WALL, CEILING, AND FINISHES ARE AS NOTED ON FINISH SCHEDULE -
SEE SHEET A8.0. GENERAL CONTRACTOR TO ADJUST SLAB, WALLS, AND CEILING
TO ACCOMMODATE OWNER SPECIFIC FINISHES AND TRIM.
PLUMBING NOTES:
G.C / OWNER TO COORDINATE LOCATION OF EXTERIOR HOSE BIBBS.
FRAMING NOTES:
STRUCTURAL ENGINEERING DOCUMENTS SUPERSEDE ARCHITECTURAL
DOCUMENTS AND SCHEDULES WITH REGARD TO SIZE OF STRUCTURAL
MEMBERS, PLACEMENT, AND CONNECTION DETAILS.
DOOR OPENINGS SET 6" OFF INTERSECTING WALL, UNLESS OTHERWISE
DIMENSIONED.
UNLESS OTHERWISE NOTED BY TYPICAL WALL SECTIONS, STRUCTURAL
ENGINEER, OR STRUCTURAL DRAWINGS.
FRAMING IS TO BE AS FOLLOWS:
WALLS:
EXTERIOR: 1/2" PLYWOOD SHEATHING (EXTERIOR SIDE) ON 2x6'S AT 16" O.C.
WITH BLOCKING AT MIDSPAN.
INTERIOR: 2x4'S AND 2x6'S AT 16" O.C. WITH BLOCKING AT MIDSPAN.
FIRST FLOOR SYSTEM:
3/4 " T&G PLYWOOD, GLUED AND NAILED ON 14" MANUFACTURED TRUSS
JOIST SYSTEM AT 16" O.C. (OR SPECIFIED INTERVALS) SEE TYPICAL WALL
SECTIONS AND DETAILS FOR VARIOUS CONNECTION DETAILS. NOTE: IF TRUSS
JOISTS (OR SIM.) ARE USED IN LIEU OF SPECIFIED MATERIALS, TRUSS
MANUFACTURER IS TO PROVIDE SHOP DRAWINGS, SUPPORT AND
CONNECTION DETAILS, AND BEAM SIZES FOR ARCHITECT/ENGINEER APPROVAL.
SECOND FLOOR SYSTEM:
3/4" T&G PLYWOOD, GLUED AND NAILED ON 14" OPEN WEB WOOD TRUSS
SYSTEM (LAYOUT AND SPACING BY STRUCTURAL ENG). SEE TYPICAL WALL
SECTIONS AND DETAILS FOR VARIOUS CONNECTION DETAILS, NOTE: IF TRUSS
JOISTS (OR SIM.) ARE USED IN LIEU OF SPECIFIED MATERIALS, TRUSS
MANUFACTURER IS TO PROVIDE SHOP DRAWINGS, SUPPORT AND
CONNECTION DETAILS, AND BEAM SIZES FOR ARCHITECT/ENGINEER APPROVAL.
PORCH FLOOR SYSTEM:
5/4" x 6" P.T. T&G WOOD DECKING (OR SYNTHETIC EQUIVALENT), GLUED AND
NAILED ON 2X12 P.T. WOOD JOIST SYSTEM AT 16" O.C. (OR SPECIFIED
INTERVALS) SEE TYPICAL WALL SECTIONS AND DETAILS FOR VARIOUS
CONNECTION DETAILS.
ATTIC FLOOR SYSTEM: (ONLY EXTENT TO BE DETERMINED BY G.C.)
3/4" T&G PLYWOOD, GLUED AND NAILED ON 2x12'S AT 16" O.C. SEE TYPICAL
WALL SECTIONS AND DETAILS FOR VARIOUS CONNECTION DETAILS. NOTE: IF
TRUSS JOISTS (OR SIM.) ARE USED IN LIEU OF SPECIFIED MATERIALS, TRUSS
MANUFACTURER IS TO PROVIDE SHOP DRAWINGS, SUPPORT AND
CONNECTION DETAILS, AND BEAM SIZES FOR ARCHITECT/ENGINEER APPROVAL.
ATTIC CEILING JOISTS / PORCH CEILING:
2x8'S AT 16" O.C. (2x10'S FOR CERTAIN SPANS)
ROOF RAFTERS:
1/2" EXT SHEATHING, NAILED ON 2x10'S WITH SIMPSON HURRICANE CLIPS AT
16" O.C. SEE TYPICAL WALL SECTIONS FOR VARIOUS CONNECTION DETAILS. IF
PRE-ENGINEERED WOOD ROOF TRUSSES ARE INSTALLED IN LIEU OF SPECIFIED
MATERIALS, TRUSS MANUFACTURER IS TO PROVIDE SHOP DRAWINGS, SUPPORT
AND CONNECTION DETAILS, AND SIZES FOR ARCHITECT/ENGINEER APPROVAL.
OR
NOTE: SEE STRUCTURAL ENGINEERING DOCUMENTS FOR SIZE, LOCATION
AND PLACEMENT OF ALL WORK DESCRIBED.
ALL DIMENSIONS ARE TO EDGE OF SLAB, BLOCK, AND FRAMING AND ARE
INDEPENDENT FROM ALL BRICK LEDGES U.N.O. G.C. TO COORDINATE SIZE
AND LOCATIONS OF ADDITIONAL BRICK LEDGES WITH PLANS, ELEVATIONS,
AND DETAILS.
10" 2 1/2"
5" 5"
7 1/2"
3/4" 3"
5"5"
3/4"3"
10"
4" CONCRETE
SLAB
KDAT WD. COLUMN
BASE TRIM
1X10 KDAT WD. COLUMN
TRIM
6X6 PT. WD. POST (SEE STRUCT.)
2X4 WD. BLOCKING
1 1/2" 5"
1 1/2"
1X1 WD. PICKET
2X4 KDAT WD. TOP CAP
1X4 KDAT WD. MEMBERS
(BELOW)
5 1/2"
3 5/8"
5 1/2"
5/8" 1 1/4"
1 1/4"5/8"
5/4X6 CEMEN. CORNER BOARDSHORIZ. CEMEN. SIDING
WD. WATERTABLE (BELOW)
CEMEN. HORIZ. SIDING
5/8" APA RATED PLYWD. SHEATHING
SELF-ADHERING FLEXIBLE FLASHING
5/4X4 CEMEN. WIN. TRIM
2X KDAT WD. SILL (BELOW)
(2) 2X6 WD. STUDS
5/8" GYP. BD. SHEATHING
R-19 BATT INSULATION
2X6 WD. STUDS @ CORNER
(1) LAYER COMM. BLDG. WRAP
WD. WINDOW CASING
WD. WIN. SILL (BELOW)
ALUM CLAD / WD. WINDOW
5/8"
5 1/2"
5/8"
3 5/8"
I SSUE
P ROJECT INFO
S HEET TITLE
D ate
P roject No.
COPYRIGHT 2019 COURT ATKINS GROUP -
THIS DRAWING IS THE PROPERTY OF THE
ARCHITECT AND IS NOT TO BE REPRODUCED IN
WHOLE OR IN PART BY ANY MEANS OR METHOD
WITHOUT THE EXPRESS WRITTEN CONSENT OF THE
ARCHITECT. ANY UNAUTHORIZED
REPRODUCTION OR REUSE OF THESE
DOCUMENTS WILL RESULT IN LEGAL ACTION.
POST OFFICE BOX 3978
BLUFFTON, SC 29910
PH: 843.815.2557
FX: 843.815.2547
WWW.COURTATKINS.COM
©
2/8/2021 11:27:26 AM
2 021.02.08
2 0-0 95
A2.1 O LD VILLAGE SQUARE - B UILDING 5
1 0 MARIANNA WAY
B LUFFTON, SC 29910
F IRST FLOOR PLAN
1/4" = 1'-0"A2.1
1 FIRST FLOOR PLAN
N O. REV. DATE DESCRIPTION
3/4" = 1'-0"A2.1
2 FIRST FLOOR - COLUMN DETAIL
3/4" = 1'-0"A2.1
3 CORNER BOARD DETAIL
ATTACHMENT 4
DN
UP
Washer Dryer
Range
WasherDryer
Range
Refrigerator
Refrigerator
A3.11
A3.0
1
A3.2
1
A3.3 1
BEDROOM 1CLOSET 1
VESTIBULE 1
BATHROOM 1
LAUNDRY
KITCHEN,
LIVING &
DINING
VESTIBULE 2
BATHROOM 2
BEDROOM 2
CLOSET 2
KITCHEN,
LIVING &
DINING
LAUNDRY
BATHROOM 1VESTIBULE 1
BEDROOM 1
VESTIBULE 2
BATHROOM 2
BEDROOM 2
CLOSET 2
CLOSET 1
OPEN AIR
PORCH
COMMUNITY
PORCH
OPEN AIR
PORCH
24' - 0" 8' - 0" 8' - 0" 8' - 0" 24' - 0"
7 1/4" 9' - 5" 31' - 0" 5' - 0"
72' - 0"
72' - 0"
5' - 0"31' - 0"9' - 5"7 1/4"
4' - 2 1/8" 5' - 10 5/8" 1' - 10 1/8" 1' - 10 1/8" 5' - 10 5/8" 4' - 2 1/8"
2' - 10"12' - 8" 12' - 8"2' - 10"10"8' - 7"
2' - 0 1/4" 7 1/4" 7' - 7 1/4" 1' - 10" 8' - 5 1/4" 1' - 10" 7' - 7 1/4" 1' - 10" 8' - 6" 1' - 10" 7' - 7 1/4" 1' - 10" 8' - 5 1/4" 1' - 10" 7' - 7 1/4" 7 1/4" 2' - 0 1/4"
2' - 10"10"8' - 7" 12' - 8"12' - 8" 2' - 10"
3' - 9 5/8" 9' - 10 1/8" 9' - 10 1/8" 3' - 9 5/8" 2' - 1" 8' - 0" 2' - 1" 3' - 9 5/8" 9' - 10 1/8" 9' - 10 1/8" 3' - 9 5/8"
11' - 7 3/4" 2' - 4 3/4" 6' - 0 1/4" 11' - 5 3/4" 8' - 0" 11' - 9 1/4" 6' - 0 1/4" 2' - 4 3/4" 11' - 4 1/4"
6' - 10 1/8" 5' - 4 3/4" 5' - 10 3/4" 5' - 11 1/8" 5" 2' - 0" 3' - 7 1/4"
14' - 0 1/2" 6' - 0 1/4" 11' - 0 1/4" 11' - 3 3/4" 6' - 0 1/4" 13' - 9"
3' - 7 1/4"2' - 0"5"5' - 11 1/8"5' - 10 3/4"5' - 4 3/4"6' - 10 1/8"
9' - 2 3/4" 4' - 9 3/4" 4' - 9 3/4" 8' - 11 1/4"
LANDING
STAIR
LANDING
A2.1
2
202E
201E
201
201A
201B
201C
201D
201H
201F
201G
202
202A
202B
202C
202D
202H
202F
202G
E EEE
E
E
E D D C C E
E
E
BB
2
A5.0
1
A5.0
3
A5.0
5
A5.0
45' - 11 1/2"
3' - 5"
200
3
A5.0
46' - 0 1/4"
SEE COVER PAGE FOR NOTES AND LIMITATIONS TO ARCHITECTURAL SCOPE
OF SERVICES.
GENERAL CONTRACTOR NOTE:
ADJUST TOP OF SLAB, WALL, AND ROOF BEARING PLATES AS REQUIRED FOR
CHANGES IN STRUCTURAL MEMBER SIZES OR EXISTING SITE CONDITIONS.
GC/OWNER TO COORDINATE ALL IN-SLAB ELECTRICAL AND PLUMBING
REQUIREMENTS WITH APPROPRIATE SUBCONTRACTOR TRADES PRIOR TO
PLACING SLAB.
DIMENSION NOTES:
DIMENSIONS ARE TO THE EDGE OF FOUNDATION AND FRAMING, U.O.N..
DO NOT SCALE DRAWINGS. CONTACT ARCHITECT WITH ANY DISCREPANCIES.
CABINET & EQUIPMENT NOTES:
CABINET LAYOUTS ARE PROVIDED FOR DESIGN CONFIGURATION ONLY. EXACT
LAYOUT AND PLACEMENT OF FIXTURES, APPLIANCES, CABINETS, AND
COUNTERTOPS ARE TO BE DETERMINED IN COORDINATION WITH OWNER AND
GENERAL CONTRACTOR.
FINISH NOTES:
FLOOR, WALL, CEILING, FINISHES AND INTERIOR TRIM ARE TO BE DETERMINED
BY THE GENERAL CONTRACTOR AND OWNER. GENERAL CONTRACTOR TO
ADJUST SLAB, WALLS, AND CEILING TO ACCOMMODATE OWNER SPECIFIC
FINISHES AND TRIM.
OR
FLOOR, WALL, CEILING, AND FINISHES ARE AS NOTED ON FINISH SCHEDULE -
SEE SHEET A8.0. GENERAL CONTRACTOR TO ADJUST SLAB, WALLS, AND CEILING
TO ACCOMMODATE OWNER SPECIFIC FINISHES AND TRIM.
PLUMBING NOTES:
G.C / OWNER TO COORDINATE LOCATION OF EXTERIOR HOSE BIBBS.
FRAMING NOTES:
STRUCTURAL ENGINEERING DOCUMENTS SUPERSEDE ARCHITECTURAL
DOCUMENTS AND SCHEDULES WITH REGARD TO SIZE OF STRUCTURAL
MEMBERS, PLACEMENT, AND CONNECTION DETAILS.
DOOR OPENINGS SET 6" OFF INTERSECTING WALL, UNLESS OTHERWISE
DIMENSIONED.
UNLESS OTHERWISE NOTED BY TYPICAL WALL SECTIONS, STRUCTURAL
ENGINEER, OR STRUCTURAL DRAWINGS.
FRAMING IS TO BE AS FOLLOWS:
WALLS:
EXTERIOR: 1/2" PLYWOOD SHEATHING (EXTERIOR SIDE) ON 2x6'S AT 16" O.C.
WITH BLOCKING AT MIDSPAN.
INTERIOR: 2x4'S AND 2x6'S AT 16" O.C. WITH BLOCKING AT MIDSPAN.
FIRST FLOOR SYSTEM:
3/4 " T&G PLYWOOD, GLUED AND NAILED ON 14" MANUFACTURED TRUSS
JOIST SYSTEM AT 16" O.C. (OR SPECIFIED INTERVALS) SEE TYPICAL WALL
SECTIONS AND DETAILS FOR VARIOUS CONNECTION DETAILS. NOTE: IF TRUSS
JOISTS (OR SIM.) ARE USED IN LIEU OF SPECIFIED MATERIALS, TRUSS
MANUFACTURER IS TO PROVIDE SHOP DRAWINGS, SUPPORT AND
CONNECTION DETAILS, AND BEAM SIZES FOR ARCHITECT/ENGINEER APPROVAL.
SECOND FLOOR SYSTEM:
3/4" T&G PLYWOOD, GLUED AND NAILED ON 14" OPEN WEB WOOD TRUSS
SYSTEM (LAYOUT AND SPACING BY STRUCTURAL ENG). SEE TYPICAL WALL
SECTIONS AND DETAILS FOR VARIOUS CONNECTION DETAILS, NOTE: IF TRUSS
JOISTS (OR SIM.) ARE USED IN LIEU OF SPECIFIED MATERIALS, TRUSS
MANUFACTURER IS TO PROVIDE SHOP DRAWINGS, SUPPORT AND
CONNECTION DETAILS, AND BEAM SIZES FOR ARCHITECT/ENGINEER APPROVAL.
PORCH FLOOR SYSTEM:
5/4" x 6" P.T. T&G WOOD DECKING (OR SYNTHETIC EQUIVALENT), GLUED AND
NAILED ON 2X12 P.T. WOOD JOIST SYSTEM AT 16" O.C. (OR SPECIFIED
INTERVALS) SEE TYPICAL WALL SECTIONS AND DETAILS FOR VARIOUS
CONNECTION DETAILS.
ATTIC FLOOR SYSTEM: (ONLY EXTENT TO BE DETERMINED BY G.C.)
3/4" T&G PLYWOOD, GLUED AND NAILED ON 2x12'S AT 16" O.C. SEE TYPICAL
WALL SECTIONS AND DETAILS FOR VARIOUS CONNECTION DETAILS. NOTE: IF
TRUSS JOISTS (OR SIM.) ARE USED IN LIEU OF SPECIFIED MATERIALS, TRUSS
MANUFACTURER IS TO PROVIDE SHOP DRAWINGS, SUPPORT AND
CONNECTION DETAILS, AND BEAM SIZES FOR ARCHITECT/ENGINEER APPROVAL.
ATTIC CEILING JOISTS / PORCH CEILING:
2x8'S AT 16" O.C. (2x10'S FOR CERTAIN SPANS)
ROOF RAFTERS:
1/2" EXT SHEATHING, NAILED ON 2x10'S WITH SIMPSON HURRICANE CLIPS AT
16" O.C. SEE TYPICAL WALL SECTIONS FOR VARIOUS CONNECTION DETAILS. IF
PRE-ENGINEERED WOOD ROOF TRUSSES ARE INSTALLED IN LIEU OF SPECIFIED
MATERIALS, TRUSS MANUFACTURER IS TO PROVIDE SHOP DRAWINGS, SUPPORT
AND CONNECTION DETAILS, AND SIZES FOR ARCHITECT/ENGINEER APPROVAL.
OR
NOTE: SEE STRUCTURAL ENGINEERING DOCUMENTS FOR SIZE, LOCATION
AND PLACEMENT OF ALL WORK DESCRIBED.
ALL DIMENSIONS ARE TO EDGE OF SLAB, BLOCK, AND FRAMING AND ARE
INDEPENDENT FROM ALL BRICK LEDGES U.N.O. G.C. TO COORDINATE SIZE
AND LOCATIONS OF ADDITIONAL BRICK LEDGES WITH PLANS, ELEVATIONS,
AND DETAILS.
I SSUE
P ROJECT INFO
S HEET TITLE
D ate
P roject No.
COPYRIGHT 2019 COURT ATKINS GROUP -
THIS DRAWING IS THE PROPERTY OF THE
ARCHITECT AND IS NOT TO BE REPRODUCED IN
WHOLE OR IN PART BY ANY MEANS OR METHOD
WITHOUT THE EXPRESS WRITTEN CONSENT OF THE
ARCHITECT. ANY UNAUTHORIZED
REPRODUCTION OR REUSE OF THESE
DOCUMENTS WILL RESULT IN LEGAL ACTION.
POST OFFICE BOX 3978
BLUFFTON, SC 29910
PH: 843.815.2557
FX: 843.815.2547
WWW.COURTATKINS.COM
©
2/8/2021 11:27:29 AM
2 021.02.08
2 0-0 95
A2.2 O LD VILLAGE SQUARE - B UILDING 5
1 0 MARIANNA WAY
B LUFFTON, SC 29910
S ECOND FLOOR
P LAN
1/4" = 1'-0"A2.2
1 SECOND FLOOR
N O. REV. DATE DESCRIPTION
ATTACHMENT 4
DN
Range
WasherDryer
Range
Washer Dryer
Refrigerator
Refrigerator
A3.11
A3.0
1
A3.2
1
A3.3 1
KITCHEN,
DINING &
LIVING
BEDROOM 1
CLOSET 1
BATHROOM
LAUNDRYLAUNDRY
KITCHEN,
DINING &
LIVING
CLOSET 1
BEDROOM 1
BATHROOMBALCONY BALCONY
LANDING
5' - 0 5/8" 20' - 11 1/2" 4' - 11 7/8" 5' - 0"
72' - 0"
82' - 0 1/4"
CLOSET 2
BEDROOM 2
CLOSET 2
BEDROOM 2
9' - 11 1/2" 2' - 0 1/4" 2' - 10 3/8" 2' - 10 3/8" 2' - 10 3/8" 2' - 0 1/4" 9' - 11 1/2"2' - 0 1/4"2' - 10 3/8"2' - 10 3/8"2' - 10 3/8"2' - 0 1/4"8' - 6 3/8"2' - 0 1/4"2' - 10 3/8"2' - 10 3/8"2' - 0 1/4"8' - 6 3/8"
8" 4' - 4 1/8" 72' - 0" 4' - 4 1/8" 8"
8' - 6 3/8" 2' - 0 3/8" 2' - 10 3/8" 2' - 10 3/8" 2' - 10 3/8" 2' - 0" 29' - 8 1/2" 2' - 0" 2' - 10 3/8" 2' - 10 3/8" 2' - 10 3/8" 2' - 0 3/8" 8' - 6 3/8"
8' - 2 7/8" 4' - 4 1/4" 7' - 11 1/4"
9' - 11 1/2" 2' - 7" 5' - 4 1/4" 4' - 0 3/4" 5' - 9 3/4" 2' - 10 5/8" 9' - 9 1/8" 2' - 10 5/8" 6' - 1 1/4" 4' - 0 3/4" 5' - 4 1/4" 12' - 3"
20' - 6 1/4" 11' - 0 1/4"
7' - 10" 2' - 4 3/4" 7' - 2" 2' - 4 3/4" 3' - 0"
5' - 7 1/8" 12' - 6 1/8" 7' - 3 1/2"
7' - 10" 2' - 4 3/4" 7' - 2" 6' - 0 3/4" 6' - 7 1/2"
2' - 4 3/4" 7' - 2" 2' - 4 3/4" 3' - 0" 7' - 3 1/2"
10' - 10 1/4" 20' - 2 3/4"
3' - 1 3/4" 2' - 4 3/4" 12' - 6 3/4" 7' - 3 1/2" 11' - 8 1/2" 8' - 6 3/8"
7' - 10" 2' - 4 3/4" 7' - 2" 6' - 0 3/4" 6' - 7 1/2"
301A
301B 301C
301D
301E
301F
301G
302A
302B302C
302E
302F
302G
302D
FFFF
1
A5.0
7 1/4" 6' - 7" 3' - 3 1/2" 3' - 3 1/2" 6' - 7" 7 1/4"
7 1/4"6' - 7"3' - 3 1/2"3' - 3 1/2"6' - 7"7 1/4"
301302
F F F F F F F
5' - 0"4' - 11 7/8"20' - 11 1/2"5' - 0 5/8"
36' - 0"
F F F F F F F F
SEE COVER PAGE FOR NOTES AND LIMITATIONS TO ARCHITECTURAL SCOPE
OF SERVICES.
GENERAL CONTRACTOR NOTE:
ADJUST TOP OF SLAB, WALL, AND ROOF BEARING PLATES AS REQUIRED FOR
CHANGES IN STRUCTURAL MEMBER SIZES OR EXISTING SITE CONDITIONS.
GC/OWNER TO COORDINATE ALL IN-SLAB ELECTRICAL AND PLUMBING
REQUIREMENTS WITH APPROPRIATE SUBCONTRACTOR TRADES PRIOR TO
PLACING SLAB.
DIMENSION NOTES:
DIMENSIONS ARE TO THE EDGE OF FOUNDATION AND FRAMING, U.O.N..
DO NOT SCALE DRAWINGS. CONTACT ARCHITECT WITH ANY DISCREPANCIES.
CABINET & EQUIPMENT NOTES:
CABINET LAYOUTS ARE PROVIDED FOR DESIGN CONFIGURATION ONLY. EXACT
LAYOUT AND PLACEMENT OF FIXTURES, APPLIANCES, CABINETS, AND
COUNTERTOPS ARE TO BE DETERMINED IN COORDINATION WITH OWNER AND
GENERAL CONTRACTOR.
FINISH NOTES:
FLOOR, WALL, CEILING, FINISHES AND INTERIOR TRIM ARE TO BE DETERMINED
BY THE GENERAL CONTRACTOR AND OWNER. GENERAL CONTRACTOR TO
ADJUST SLAB, WALLS, AND CEILING TO ACCOMMODATE OWNER SPECIFIC
FINISHES AND TRIM.
OR
FLOOR, WALL, CEILING, AND FINISHES ARE AS NOTED ON FINISH SCHEDULE -
SEE SHEET A8.0. GENERAL CONTRACTOR TO ADJUST SLAB, WALLS, AND CEILING
TO ACCOMMODATE OWNER SPECIFIC FINISHES AND TRIM.
PLUMBING NOTES:
G.C / OWNER TO COORDINATE LOCATION OF EXTERIOR HOSE BIBBS.
FRAMING NOTES:
STRUCTURAL ENGINEERING DOCUMENTS SUPERSEDE ARCHITECTURAL
DOCUMENTS AND SCHEDULES WITH REGARD TO SIZE OF STRUCTURAL
MEMBERS, PLACEMENT, AND CONNECTION DETAILS.
DOOR OPENINGS SET 6" OFF INTERSECTING WALL, UNLESS OTHERWISE
DIMENSIONED.
UNLESS OTHERWISE NOTED BY TYPICAL WALL SECTIONS, STRUCTURAL
ENGINEER, OR STRUCTURAL DRAWINGS.
FRAMING IS TO BE AS FOLLOWS:
WALLS:
EXTERIOR: 1/2" PLYWOOD SHEATHING (EXTERIOR SIDE) ON 2x6'S AT 16" O.C.
WITH BLOCKING AT MIDSPAN.
INTERIOR: 2x4'S AND 2x6'S AT 16" O.C. WITH BLOCKING AT MIDSPAN.
FIRST FLOOR SYSTEM:
3/4 " T&G PLYWOOD, GLUED AND NAILED ON 14" MANUFACTURED TRUSS
JOIST SYSTEM AT 16" O.C. (OR SPECIFIED INTERVALS) SEE TYPICAL WALL
SECTIONS AND DETAILS FOR VARIOUS CONNECTION DETAILS. NOTE: IF TRUSS
JOISTS (OR SIM.) ARE USED IN LIEU OF SPECIFIED MATERIALS, TRUSS
MANUFACTURER IS TO PROVIDE SHOP DRAWINGS, SUPPORT AND
CONNECTION DETAILS, AND BEAM SIZES FOR ARCHITECT/ENGINEER APPROVAL.
SECOND FLOOR SYSTEM:
3/4" T&G PLYWOOD, GLUED AND NAILED ON 14" OPEN WEB WOOD TRUSS
SYSTEM (LAYOUT AND SPACING BY STRUCTURAL ENG). SEE TYPICAL WALL
SECTIONS AND DETAILS FOR VARIOUS CONNECTION DETAILS, NOTE: IF TRUSS
JOISTS (OR SIM.) ARE USED IN LIEU OF SPECIFIED MATERIALS, TRUSS
MANUFACTURER IS TO PROVIDE SHOP DRAWINGS, SUPPORT AND
CONNECTION DETAILS, AND BEAM SIZES FOR ARCHITECT/ENGINEER APPROVAL.
PORCH FLOOR SYSTEM:
5/4" x 6" P.T. T&G WOOD DECKING (OR SYNTHETIC EQUIVALENT), GLUED AND
NAILED ON 2X12 P.T. WOOD JOIST SYSTEM AT 16" O.C. (OR SPECIFIED
INTERVALS) SEE TYPICAL WALL SECTIONS AND DETAILS FOR VARIOUS
CONNECTION DETAILS.
ATTIC FLOOR SYSTEM: (ONLY EXTENT TO BE DETERMINED BY G.C.)
3/4" T&G PLYWOOD, GLUED AND NAILED ON 2x12'S AT 16" O.C. SEE TYPICAL
WALL SECTIONS AND DETAILS FOR VARIOUS CONNECTION DETAILS. NOTE: IF
TRUSS JOISTS (OR SIM.) ARE USED IN LIEU OF SPECIFIED MATERIALS, TRUSS
MANUFACTURER IS TO PROVIDE SHOP DRAWINGS, SUPPORT AND
CONNECTION DETAILS, AND BEAM SIZES FOR ARCHITECT/ENGINEER APPROVAL.
ATTIC CEILING JOISTS / PORCH CEILING:
2x8'S AT 16" O.C. (2x10'S FOR CERTAIN SPANS)
ROOF RAFTERS:
1/2" EXT SHEATHING, NAILED ON 2x10'S WITH SIMPSON HURRICANE CLIPS AT
16" O.C. SEE TYPICAL WALL SECTIONS FOR VARIOUS CONNECTION DETAILS. IF
PRE-ENGINEERED WOOD ROOF TRUSSES ARE INSTALLED IN LIEU OF SPECIFIED
MATERIALS, TRUSS MANUFACTURER IS TO PROVIDE SHOP DRAWINGS, SUPPORT
AND CONNECTION DETAILS, AND SIZES FOR ARCHITECT/ENGINEER APPROVAL.
OR
NOTE: SEE STRUCTURAL ENGINEERING DOCUMENTS FOR SIZE, LOCATION
AND PLACEMENT OF ALL WORK DESCRIBED.
ALL DIMENSIONS ARE TO EDGE OF SLAB, BLOCK, AND FRAMING AND ARE
INDEPENDENT FROM ALL BRICK LEDGES U.N.O. G.C. TO COORDINATE SIZE
AND LOCATIONS OF ADDITIONAL BRICK LEDGES WITH PLANS, ELEVATIONS,
AND DETAILS.
I SSUE
P ROJECT INFO
S HEET TITLE
D ate
P roject No.
COPYRIGHT 2019 COURT ATKINS GROUP -
THIS DRAWING IS THE PROPERTY OF THE
ARCHITECT AND IS NOT TO BE REPRODUCED IN
WHOLE OR IN PART BY ANY MEANS OR METHOD
WITHOUT THE EXPRESS WRITTEN CONSENT OF THE
ARCHITECT. ANY UNAUTHORIZED
REPRODUCTION OR REUSE OF THESE
DOCUMENTS WILL RESULT IN LEGAL ACTION.
POST OFFICE BOX 3978
BLUFFTON, SC 29910
PH: 843.815.2557
FX: 843.815.2547
WWW.COURTATKINS.COM
©
2/8/2021 11:27:32 AM
2 021.02.08
2 0-0 95
A2.3 O LD VILLAGE SQUARE - B UILDING 5
1 0 MARIANNA WAY
B LUFFTON, SC 29910
L OFT LEVEL PLAN
1/4" = 1'-0"A2.3
1 LOFT FLR. HT.
N O. REV. DATE DESCRIPTION
ATTACHMENT 4
SEE COVER PAGE FOR NOTES AND LIMITATIONS TO ARCHITE CTURAL SCOPE
OF SERVICES.
GENERAL CONTRACTOR NOTE:
ADJUST TOP OF SLAB, WALL, AND ROOF BEARING PLATES AS REQUIRED FOR
CHANGES IN STRUCTURAL MEMBER SIZES OR EXISTING SITE CONDITIONS.
GC/OWNER TO COORDINATE ALL IN-SLAB ELECTRICAL AND PLUMBING
REQUIREMENTS WITH APPROPRIATE SUBCONTRACTOR TRADES PRIOR TO
PLACING SLAB.
DIMENSION NOTES:
DIMENSIONS ARE TO THE EDGE OF FOUNDATION AND FRAMING, U.O.N..
DO NOT SCALE DRAWINGS. CONTACT ARCHITECT WITH ANY DISCREPANCIES.
CABINET & EQUIPMENT NOTES:
CABINET LAYOUTS ARE PROVIDED FOR DESIGN CONFIGURATION ONLY. EXACT
LAYOUT AND PLACEMENT OF FIXTURES, APPLIANCES, CABINETS, AND
COUNTERTOPS ARE TO BE DETERMINED IN COORDINATION WITH OWNER AND
GENERAL CONTRACTOR.
FINISH NOTES:
FLOOR, WALL, CEILING, FINISHES AND INTERIOR TRIM ARE TO BE DETERMINED
BY THE GENERAL CONTRACTOR AND OWNER. GENERAL CONTRACTOR TO
ADJUST SLAB, WALLS, AND CEILING TO ACCOMMODATE OWNER SPECIFIC
FINISHES AND TRIM.
OR
FLOOR, WALL, CEILING, AND FINISHES ARE AS NOTED ON FINISH SCHEDULE -
SEE SHEET A8.0. GENERAL CONTRACTOR TO ADJUST SLAB, WALLS, AND CEILING
TO ACCOMMODATE OWNER SPECIFIC FINISHES AND TRIM.
PLUMBING NOTES:
G.C / OWNER TO COORDINATE LOCATION OF EXTERIOR HOSE BIBBS.
FRAMING NOTES:
STRUCTURAL ENGINEERING DOCUMENTS SUPERSEDE ARCHITECTURAL
DOCUMENTS AND SCHEDULES WITH REGARD TO SIZE OF STRUCTURAL
MEMBERS, PLACEMENT, AND CONNECTION DETAILS.
DOOR OPENINGS SET 6" OFF INTERSECTING WALL, UNLESS OTHERWISE
DIMENSIONED.
UNLESS OTHERWISE NOTED BY TYPICAL WALL SECTIONS, STRUCTURAL
ENGINEER, OR STRUCTURAL DRAWINGS.
FRAMING IS TO BE AS FOLLOWS:
WALLS:
EXTERIOR: 1/2" PLYWOOD SHEATHING (EXTERIOR SIDE) ON 2x6'S AT 16" O.C.
WITH BLOCKING AT MIDSPAN.
INTERIOR: 2x4'S AND 2x6'S AT 16" O.C. WITH BLOCKING AT MIDSPAN.
FIRST FLOOR SYSTEM:
3/4 " T&G PLYWOOD, GLUED AND NAILED ON 14" MANUFACTURED TRUSS
JOIST SYSTEM AT 16" O.C. (OR SPECIFIED INTERVALS) SEE TYPICAL WALL
SECTIONS AND DETAILS FOR VARIOUS CONNECTION DETAILS. NOTE: IF TRUSS
JOISTS (OR SIM.) ARE USED IN LIEU OF SPECIFIED MATERIALS, TRUSS
MANUFACTURER IS TO PROVIDE SHOP DRAWINGS, SUPPORT AND
CONNECTION DETAILS, AND BEAM SIZES FOR ARCHITECT/ENGINEER APPROVAL.
SECOND FLOOR SYSTEM:
3/4" T&G PLYWOOD, GLUED AND NAILED ON 14" OPEN WEB WOOD TRUSS
SYSTEM (LAYOUT AND SPACING BY STRUCTURAL ENG). SEE TYPICAL WALL
SECTIONS AND DETAILS FOR VARIOUS CONNECTION DETAILS, NOTE: IF TRUSS
JOISTS (OR SIM.) ARE USED IN LIEU OF SPECIFIED MATERIALS, TRUSS
MANUFACTURER IS TO PROVIDE SHOP DRAWINGS, SUPPORT AND
CONNECTION DETAILS, AND BEAM SIZES FOR ARCHITECT/ENGINEER APPROVAL.
PORCH FLOOR SYSTEM:
5/4" x 6" P.T. T&G WOOD DECKING (OR SYNTHETIC EQUIVALENT), GLUED AND
NAILED ON 2X12 P.T. WOOD JOIST SYSTEM AT 16" O.C. (OR SPECIFIED
INTERVALS) SEE TYPICAL WALL SECTIONS AND DETAILS FOR VARIOUS
CONNECTION DETAILS.
ATTIC FLOOR SYSTEM: (ONLY EXTENT TO BE DETERMINED BY G.C.)
3/4" T&G PLYWOOD, GLUED AND NAILED ON 2x12'S AT 16" O.C. SEE TYPICAL
WALL SECTIONS AND DETAILS FOR VARIOUS CONNECTION DETAILS. NOTE: IF
TRUSS JOISTS (OR SIM.) ARE USED IN LIEU OF SPECIFIED MATERIALS, TRUSS
MANUFACTURER IS TO PROVIDE SHOP DRAWINGS, SUPPORT AND
CONNECTION DETAILS, AND BEAM SIZES FOR ARCHITECT/ENGINEER APPROVAL.
ATTIC CEILING JOISTS / PORCH CEILING:
2x8'S AT 16" O.C. (2x10'S FOR CERTAIN SPANS)
ROOF RAFTERS:
1/2" EXT SHEATHING, NAILED ON 2x10'S WITH SIMPSON HURRICANE CLIPS AT
16" O.C. SEE TYPICAL WALL SECTIONS FOR VARIOUS CONNECTION DETAILS. IF
PRE-ENGINEERED WOOD ROOF TRUSSES ARE INSTALLED IN LIEU OF SPECIFIED
MATERIALS, TRUSS MANUFACTURER IS TO PROVIDE SHOP DRAWINGS, SUPPORT
AND CONNECTION DETAILS, AND SIZES FOR ARCHITECT/ENGINEER APPROVAL.
OR
NOTE: SEE STRUCTURAL ENGINEERING DOCUMENTS FOR SIZE, LOCATION
AND PLACEMENT OF ALL WORK DESCRIBED.
ALL DIMENSIONS ARE TO EDGE OF SLAB, BLOCK, AND FRAMING AND ARE
INDEPENDENT FROM ALL BRICK LEDGES U.N.O. G.C. TO COORDINATE SIZE
AND LOCATIONS OF ADDITIONAL BRICK LEDGES WITH PLANS, ELEVATIONS,
AND DETAILS.
A3.11
A3.0
1
A3.2
1
A3.3 1
2'-2" OVERHANG
1'-9" OVERHANG 1'-9" OVERHANG
2'-2" OVERHANG2'-2" OVERHANG
2'-2" OVERHANG7' - 1 5/8"1'-7" OVERHANG
1'-7" OVERHANG
1'-7" OVERHANG
10/12 10/1210/12 10/12
10/12 10/12
6/12
6/12
3/12 3/12
1'-2" OVERHANG1'-2" OVERHANG
1'-2" OVERHANG 1'-2" OVERHANG
6/12 6/12
6/12
6/12 6/12
6/12
6/126/12
6/12
6/12
6/12
6/12
6/12
6/12
6/12
6/12
6/12
1'-9" OVERHANG
1'-9" OVERHANG
1'-9" OVERHANG
1'-9" OVERHANG
1'-9" OVERHANG
6/12
3/12
1'-7" OVERHANG 1'-7" OVERHANG
7' - 1 3/4"1'-7" OVERHANG
I SSUE
P ROJECT INFO
S HEET TITLE
D ate
P roject No.
COPYRIGHT 2019 COURT ATKINS GROUP -
THIS DRAWING IS THE PROPERTY OF THE
ARCHITECT AND IS NOT TO BE REPRODUCED IN
WHOLE OR IN PART BY ANY MEANS OR METHOD
WITHOUT THE EXPRESS WRITTEN CONSENT OF THE
ARCHITECT. ANY UNAUTHORIZED
REPRODUCTION OR REUSE OF THESE
DOCUMENTS WILL RESULT IN LEGAL ACTION.
POST OFFICE BOX 3978
BLUFFTON, SC 29910
PH: 843.815.2557
FX: 843.815.2547
WWW.COURTATKINS.COM
©
2/8/2021 11:27:33 AM
2 021.02.08
2 0-0 95
A2.4 O LD VILLAGE SQUARE - B UILDING 5
1 0 MARIANNA WAY
B LUFFTON, SC 29910
R OOF PLAN
1/4" = 1'-0"A2.4
1 ROOF PLAN
N O. REV. DATE DESCRIPTION
ATTACHMENT 4
FIRST FLOOR HT.
PORCH HT.
SECOND FLOOR
B.O. BEAM
LOFT FLR. HT.
DORMER BRG.
4' - 10 1/4"1' - 10"2' - 9 1/2"5' - 2 1/2"1' - 9"9' - 0"12' - 0"3"
37' - 8 1/4"
EEEE
A A A A
FFFF
104A
100
103A
202A 201A
2X KDAT WD TRIM (CHAMFER
TO DRAIN)ON 1X4 CEMEN.
TRIM OVER 1X6 CEMEN. TRIM
1X6 CEMEN. CORNER BD.
10X10 KDAT WD. COLUMN
KDAT WD. COLUMN CAP
KDAT WD. COLUMN BASE
2X KDAT WD TRIM (CHAMFER
TO DRAIN)ON 1X4 CEMEN.
TRIM ON 1X6 CEMEN. TRIM
OVER 1X10 CEMEN. TRIM
ALUM. CLAD / WD. DOUBLE
-HUNG WINDOW
KDAT WD. SHUTTER
CEMENTITIOUS HORIZ. SIDING
W/ 7" EXPOSURE
2X KDAT WD TRIM (CHAMFER
TO DRAIN)ON 1X4 CEMEN.
TRIM ON 1X6 CEMEN. TRIM
OVER 1X10 CEMEN. TRIM
KDAT WD. BALUSTER
KDAT WD. CAP
KDAT WD. BASE
ASPHALT SHINGLES
1X10 CEMEN. CORNER BD.
1X4 CEMEN. TRIM ON 1X6
CEMEN.TRIM FASCIA
STANDING SEAM METAL ROOF
ALUM. CLAD. / WD. DOUBLE
-HUNG WINDOW
ALUM. CLAD. / WD. PATIO DOORINSWING IRON GATES W/ TRANSOMALUM. CLAD. / WD. PATIO DOOR CEMEN. HORIZ. SIDING W/ 7" EXPOSUREALUM. CLAD / WD. DOUBLE-HUNG WINDOW
2X KDAT WD TRIM (CHAMFER
TO DRAIN)ON 1X4 CEMEN.
TRIM OVER 1X6 CEMEN. TRIM
1X6 CEMEN. CORNER BD.
10X10 KDAT WD. COLUMN
KDAT WD. COLUMN CAP
KDAT WD. COLUMN BASE
2X KDAT WD TRIM (CHAMFER
TO DRAIN)ON 1X4 CEMEN.
TRIM ON 1X6 CEMEN. TRIM
OVER 1X10 CEMEN. TRIM
STANDING SEAM METAL ROOF
HORIZ. CEMEN. SIDING W/ 7" EXPOSURE
INSWING IRON GATES
PORCH RF. RIDGE
REAR RF. RIDGE
MAIN RF. RIDGE
3
A5.0
2
A5.0
6
12
6
12
6
12
6
12
6
12
6
12
I SSUE
P ROJECT INFO
S HEET TITLE
D ate
P roject No.
COPYRIGHT 2019 COURT ATKINS GROUP -
THIS DRAWING IS THE PROPERTY OF THE
ARCHITECT AND IS NOT TO BE REPRODUCED IN
WHOLE OR IN PART BY ANY MEANS OR METHOD
WITHOUT THE EXPRESS WRITTEN CONSENT OF THE
ARCHITECT. ANY UNAUTHORIZED
REPRODUCTION OR REUSE OF THESE
DOCUMENTS WILL RESULT IN LEGAL ACTION.
POST OFFICE BOX 3978
BLUFFTON, SC 29910
PH: 843.815.2557
FX: 843.815.2547
WWW.COURTATKINS.COM
©
2/8/2021 11:27:44 AM
2 021.02.08
2 0-0 95
A3.0 O LD VILLAGE SQUARE - B UILDING 5
1 0 MARIANNA WAY
B LUFFTON, SC 29910
F RONT EXTERIOR
E LEVATION
1/4" = 1'-0"A3.0
1 FRONT EXTERIOR ELEVATION
N O. REV. DATE DESCRIPTION
ATTACHMENT 4
FIRST FLOOR HT.
PORCH HT.
SECOND FLOOR
B.O. BEAM
LOFT FLR. HT.
DORMER BRG.
4' - 10 1/4"1' - 10"2' - 9 1/2"5' - 2 1/2"1' - 9"9' - 0"12' - 0"3"
37' - 8 1/4"
EE
A
3
12
301D
3
12
1X6 CEMEN. CORNER BD.
KDAT WD. COLUMN BASE
2X KDAT WD TRIM (CHAMFER
TO DRAIN)ON 1X4 CEMEN.
TRIM ON 1X6 CEMEN. TRIM
OVER 1X10 CEMEN. TRIM
ALUM. CLAD / WD. DOUBLE
-HUNG WINDOW
CEMENTITIOUS HORIZ. SIDING
W/ 7" EXPOSURE
KDAT WD. BALUSTER
KDAT WD. CAP
ASPHALT SHINGLES
1X4 CEMEN. TRIM ON 1X6
CEMEN.TRIM FASCIA
ALUM. CLAD. / WD. PATIO DR.
KDAT WD. BASE
1X6 CEMEN. CORNER BD.
10X10 KDAT WD. COLUMN
KDAT WD. COLUMN CAP
KDAT WD. COLUMN BASE
2X KDAT WD TRIM (CHAMFER
TO DRAIN)ON 1X4 CEMEN.
TRIM ON 1X6 CEMEN. TRIM
OVER 1X10 CEMEN. TRIM
KDAT WD. BOTTOM RAIL
1X1 PT. WD. PICKETS
KDAT WD. TOP RAIL
ALUM. CLAD / WD. DOUBLE
-HUNG WINDOW
CEMENTITIOUS HORIZ. SIDING
W/ 7" EXPOSURE
1X10 CEMEN. CORNER BOARD
1X4 CEMEN. TRIM ON 1X6
CEMEN.TRIM FASCIA
STANDING SEAM METAL ROOF
CEMEN. HORIZ. SIDING W/ 7"
EXPOSURE
ALUM. CLAD / WD. PICTURE WINDOW
PORCH RF. RIDGE
REAR RF. RIDGE
MAIN RF. RIDGE
5
A5.0
10
12
6
12
10
12
6
12
B
103B
6
12
B
I SSUE
P ROJECT INFO
S HEET TITLE
D ate
P roject No.
COPYRIGHT 2019 COURT ATKINS GROUP -
THIS DRAWING IS THE PROPERTY OF THE
ARCHITECT AND IS NOT TO BE REPRODUCED IN
WHOLE OR IN PART BY ANY MEANS OR METHOD
WITHOUT THE EXPRESS WRITTEN CONSENT OF THE
ARCHITECT. ANY UNAUTHORIZED
REPRODUCTION OR REUSE OF THESE
DOCUMENTS WILL RESULT IN LEGAL ACTION.
POST OFFICE BOX 3978
BLUFFTON, SC 29910
PH: 843.815.2557
FX: 843.815.2547
WWW.COURTATKINS.COM
©
2/8/2021 11:27:54 AM
2 021.02.08
2 0-0 95
A3.1 O LD VILLAGE SQUARE - B UILDING 5
1 0 MARIANNA WAY
B LUFFTON, SC 29910
R IGHT SIDE
E XTERIOR
E LEVATION
1/4" = 1'-0"A3.1
1 RIGHT SIDE EXTERIOR ELEVATION
N O. REV. DATE DESCRIPTION
ATTACHMENT 4
FIRST FLOOR HT.
PORCH HT.
SECOND FLOOR
B.O. BEAM
LOFT FLR. HT.
DORMER BRG.
3" 12' - 0" 9' - 0" 1' - 9" 8' - 0" 1' - 10" 4' - 10 1/4"
37' - 8 1/4"CC
E
D D
E
A
C C D D
A
102 101
A6.0
1
2X KDAT WD TRIM (CHAMFER
TO DRAIN)ON 1X4 CEMEN.
TRIM OVER 1X6 CEMEN. TRIM
1X6 CEMEN. CORNER BD.
KDAT WD. COLUMN BASE
2X KDAT WD TRIM (CHAMFER
TO DRAIN)ON 1X4 CEMEN.
TRIM ON 1X6 CEMEN. TRIM
OVER 1X10 CEMEN. TRIM
ALUM. CLAD / WD. DOUBLE
-HUNG WINDOW
KDAT WD. SHUTTER
CEMENTITIOUS HORIZ. SIDING
W/ 7" EXPOSURE
2X KDAT WD TRIM (CHAMFER
TO DRAIN)ON 1X4 CEMEN.
TRIM ON 1X6 CEMEN. TRIM
OVER 1X10 CEMEN. TRIM
KDAT WD. BALUSTER
KDAT WD. CAP
KDAT WD. BASE
ASPHALT SHINGLES
1X10 CEMEN. CORNER BOARD
1X4 CEMEN. TRIM ON 1X6
CEMEN.TRIM FASCIA
STANDING SEAM METAL ROOF
ALUM. CLAD. / WD. DOUBLE
-HUNG WINDOW
HORIZ. KDAT WD. SLATS @ SERVICE YARD KDAT WD. GUARDRAIL HORIZ. KDAT WD. SLATS @ SERVICE YARDCEMEN. HORIZ. SIDING W/ 7" EXPOSURE ALUM. CLAD / WD. DOUBLE-HUNG WINDOW
2X KDAT WD TRIM (CHAMFER
TO DRAIN)ON 1X4 CEMEN.
TRIM OVER 1X6 CEMEN. TRIM
1X6 CEMEN. CORNER BD.
KDAT WD. COLUMN BASE
2X KDAT WD TRIM (CHAMFER
TO DRAIN)ON 1X4 CEMEN.
TRIM ON 1X6 CEMEN. TRIM
OVER 1X10 CEMEN. TRIM
ASPHALT SHINGLES
HORIZ. CEMEN. SIDING W/ 7" EXPOSURE
KDAT WD. FRAME
STANDING SEAM METAL ROOF
KDAT WD. SHUTTER
REAR RF. RIDGE
MAIN RF. RIDGE
4
A5.0
6
12
6
12
6
12
6
12
6
12
6
12
F F F F F F FF
I SSUE
P ROJECT INFO
S HEET TITLE
D ate
P roject No.
COPYRIGHT 2019 COURT ATKINS GROUP -
THIS DRAWING IS THE PROPERTY OF THE
ARCHITECT AND IS NOT TO BE REPRODUCED IN
WHOLE OR IN PART BY ANY MEANS OR METHOD
WITHOUT THE EXPRESS WRITTEN CONSENT OF THE
ARCHITECT. ANY UNAUTHORIZED
REPRODUCTION OR REUSE OF THESE
DOCUMENTS WILL RESULT IN LEGAL ACTION.
POST OFFICE BOX 3978
BLUFFTON, SC 29910
PH: 843.815.2557
FX: 843.815.2547
WWW.COURTATKINS.COM
©
2/8/2021 11:28:04 AM
2 021.02.08
2 0-0 95
A3.2 O LD VILLAGE SQUARE - B UILDING 5
1 0 MARIANNA WAY
B LUFFTON, SC 29910
R EAR EXTERIOR
E LEVATION
1/4" = 1'-0"A3.2
1 REAR EXTERIOR ELEVATION
N O. REV. DATE DESCRIPTION
ATTACHMENT 4
FIRST FLOOR HT.
PORCH HT.
SECOND FLOOR
B.O. BEAM
LOFT FLR. HT.
DORMER BRG.
4' - 10 1/4"1' - 10"2' - 9 1/2"5' - 2 1/2"1' - 9"9' - 0"12' - 0"3"
37' - 8 1/4"
EE
A A
10
12
6
12
3
12
302D
1X6 CEMEN. CORNER BD.
KDAT WD. COLUMN BASE
2X KDAT WD TRIM (CHAMFER
TO DRAIN)ON 1X4 KCEMEN.
TRIM ON 1X6 CEMEN. TRIM
OVER 1X10 CEMEN. TRIM
ALUM. CLAD / WD. DOUBLE
-HUNG WINDOW
CEMENTITIOUS HORIZ. SIDING
W/ 7" EXPOSURE
KDAT WD. BALUSTER
KDAT WD. CAP
ASPHALT SHINGLES
1X4 CEMEN. TRIM ON 1X6
CEMEN.TRIM FASCIA
ALUM. CLAD. / WD. PATIO DOOR
KDAT WD. BASE
1X6 CEMEN. CORNER BD.
10X10 KDAT WD. COLUMN
KDAT WD. COLUMN CAP
KDAT WD. COLUMN BASE
2X KDAT WD TRIM (CHAMFER
TO DRAIN)ON 1X4 CEMEN.
TRIM ON 1X6 CEMEN. TRIM
OVER 1X10 CEMEN. TRIM
KDAT WD. BOTTOM RAIL
1X1 PT. WD. PICKETS
KDAT WD. TOP RAIL
ALUM. CLAD / WD. DOUBLE
-HUNG WINDOW
CEMENTITIOUS HORIZ. SIDING
W/ 7" EXPOSURE
1X10 CEMEN. CORNER BOARD
1X4 CEMEN. TRIM ON 1X6
CEMEN.TRIM FASCIA
STANDING SEAM METAL ROOF
CEMEN. HORIZ. SIDING W/ 7"
EXPOSURE
ALUM. CLAD / WD. PICTURE WINDOW
PORCH RF. RIDGE
REAR RF. RIDGE
MAIN RF. RIDGE
5
A5.0
6
12
10
12
6
12
B
B
I SSUE
P ROJECT INFO
S HEET TITLE
D ate
P roject No.
COPYRIGHT 2019 COURT ATKINS GROUP -
THIS DRAWING IS THE PROPERTY OF THE
ARCHITECT AND IS NOT TO BE REPRODUCED IN
WHOLE OR IN PART BY ANY MEANS OR METHOD
WITHOUT THE EXPRESS WRITTEN CONSENT OF THE
ARCHITECT. ANY UNAUTHORIZED
REPRODUCTION OR REUSE OF THESE
DOCUMENTS WILL RESULT IN LEGAL ACTION.
POST OFFICE BOX 3978
BLUFFTON, SC 29910
PH: 843.815.2557
FX: 843.815.2547
WWW.COURTATKINS.COM
©
2/8/2021 11:28:13 AM
2 021.02.08
2 0-0 95
A3.3 O LD VILLAGE SQUARE - B UILDING 5
1 0 MARIANNA WAY
B LUFFTON, SC 29910
L EFT SIDE EXTERIOR
E LEVATION
1/4" = 1'-0"A3.3
1 LEFT SIDE EXTERIOR ELEVATION
N O. REV. DATE DESCRIPTION
ATTACHMENT 4
ROOF BEARING
ROOF BEARING
ROOF BEARING
ROOF BEARING
DOOR HEAD HT.
DOOR HEAD HT.
B.O. BEAM
T.O. SERVICE YARD
D ORMER RF. BRG.
W IN. HD. HT.
W IN. SILL HT.
D OOR HEAD HT.
D OOR HEAD HT.
T .O. GUARDRAIL
T .O. GUARDRAIL
PORCH RF. BRG.
T.O. GUARDRAIL
T.O. GUARDRAIL
FIRST FLOOR HT.
PORCH HT.
SECOND FLOOR
B.O. BEAM
LOFT FLR. HT.
1' - 2"1' - 7 1/2"1' - 5 1/2"1' - 9"1' - 11 3/4"7' - 0 1/4"1' - 9"1' - 2 3/4"9' - 0 1/4"3"
ROOFING FELT (# PER ROOFING MANF.)
5/8" APA RATED PLYWD. SHEATHING
5/8" APA RATED PLYWD. SHEATHING
2X10 WD. BLOCKING (CONT.)
2X6 WD. STUDS @ 16" O.C. - TYP.
5/8" APA RATED PLYWD. SHEATHING
2X6 WD. STUD SILL PLATE
WD. BEAM (SEE STRUCT.)
JOIST HANGER (SEE STRUCT.)
2X6 WD. CEILING JOISTS @
16" O.C. - TYP.
1X6 KDAT WD. T&G CEILING
1X6 CEMEN. TRIM
PRE-FIN. MTL. FLASH.
WD. BEAM (SEE STRUCT.)
HORIZ. CEMEN SIDING W/ 7" EXP.
2X6 WD. STUDS @ 16" O.C. - TYP.
PRE-FIN. MTL. FLASHING
2X4 KDAT WD. CAP
2X6 KDAT WD. HEAD TRIM
WD. HEADER (SEE STRUCT.)
IRON PICKET @ GATE
IRON PICKET @ GATE
KDAT WD. DOOR STILES
KDAT WD. DOOR STILES
1X6 KDAT WD. DECK BOARDS
3/4" APA RATED PLYWD. SUBFLOOR
2X WD. SLEEPER
TPO MEMBRANE
2X10 WD. RAFTERS @ 16" O.C. - TYP.
SIMPSON RAFTER HANGER
1X WD. BLOCKING
1X6 KDAT WD. T&G CEILING
2X6 WD. STUDS @ 16" O.C. - TYP.
PRE-FIN. MTL. FLASHING
2X4 KDAT WD. CAP
2X6 KDAT WD. HEAD TRIM
WD. HEADER (SEE STRUCT.)
IRON PICKET @ GATE
KDAT WD. DOOR STILES
KDAT WD. DOOR STILES
PRE-FIN. MTL. FLASHING
ALUM. CLAD / WD. TRANSOM WINDOW
ENGINEERED WD. COLUMN
1X6 CEMEN. CORNER BOARDS
PT. WD. GATE (BEYOND)
HORIZ. SIDING (BEYOND)
PT. WD. GATE (BEYOND)
1X6 CEMEN. CORNER BOARDS
4" 5 1/2"
3/4"11 1/4"3/4"
5 1/2"
JOIST HANGER (SEE STRUCT.)
STANDING SEAM MTL. ROOF
2X4 KDAT WD. SILL TRIM
PRE-FIN. MTL. SILL PAN FLASHING
ALUM. CLAD / WD. DOUBLR HUNG WIN.
3/4"11 1/4"3/4"
4' - 8"
WD. HEADER (SEE STRUCT.)
2X6 KDAT WD. TRIM @ HEAD
1X6 KDAT WD. T&G SOFFIT
1X4 CEMEN. TRIM
ON 1X8 CEMEN TRIM
PRE-FIN. MTL. DRIP EDGE
5/8" APA RATED PLYWD. SHEATHING
ROOFING FELT (# PER ROOFING
MANF.)
STANDING SEAM METAL ROOF
2X WD. BLOCKING (CONT.)
2X KDAT WD. TRIM
2X10 WD. ROOF RAFTERS @ 16"
O.C. - TYP.
1X6 KDAT WD. T&G CEILING
(2) 2X6 WD. TOP PLATES
2X10 WD. BLOCKING - TYP.
3' - 0 1/2" 4"
1' - 10 1/4"
FIRST FLOOR HT.
PORCH HT.
4' - 6 1/2"3"
1"5 1/2"1"
2 3/4" 4' - 2 1/8" 3 1/4"
2 3/4" 1/2" 3' - 7 5/8" 1/2" 2 3/4"
4' - 8 1/8"
2X4 WD. DOOR FRAME MEMBER (BEYOND)
1X6 PT. WD. SLATS (BEYOND)
PRE-FIN. MTL FLASHING @ CAP (@ GATE)1X6 PT. WD. CAP @ PERIM.
PRE-FIN. MTL. FLASHING
1X6 PT. WD. SLATS
1X6 PT. WD. TRIM WRAP @ POST
4X4 PT. WD. POST (BEYOND)
2X4 PT. WD. BRACING @ GATE
SIMPSON POST BASE
SERVICE YARD CONC. SLAB
REINFORCING (SEE STRUCT.)
5 1/4" 5" 5" 5 1/2"
GAVLANIZED MTL. HINGES
4 1/2"1"
PRE-FIN. MTL FLASHING @ CAP
GAVLANIZED MTL. HINGES
F IRST FLOOR HT.
P ORCH HT.
S ECOND FLOOR
L OFT FLR. HT.
1 ' - 2"4 ' - 8"3 ' - 1"3 ' - 9"3 ' - 2 7/8"3 ' - 9 1/8"3 ' - 0"5 ' - 5 7/8"3 ' - 6 1/8"3 "
4 1/2"
ALUM. CLAD / WD. DOUBLE HUNG WIN.
WD. HEADER (SEE STRUCT.)
2X6 KDAT WD. TRIM @ HEAD
1X6 KDAT WD. T&G SOFFIT
1X4 CEMEN. TRIM ON 1X8 CEMEN TRIM
PRE-FIN. MTL. DRIP EDGE
5/8" APA RATED PLYWD. SHEATHING
ROOFING FELT (# PER ROOFING MANF.)
2X8 WD. BLOCKING
2X WD. BLOCKING (CONT.)
5/4"X6 KDAT WD. TRIM @ SILL
PRE-FIN. METAL SILL FLASHING
PRE-FIN. MTL. FLASHING
STANDING SEAM METAL ROOF
5/8" APA RATED PLYWD. SHEATHING
2X8 WD. RAFTERS @ 16" O.C. - TYP.
JOIST HANGER
2X WD. BLOCKING (CONT.)
5/8" APA RATED PLYWD. SHEATHING
(2) 2X6 WD. SILL PLATES
3/4" APA RATED PLYWD. SUBFLOOR
R-19 BATT INSULATION
1X6 KDAT WD. T&G CEILING
1X6 CEMEN. TRIM
PRE-FIN. MTL. FLASHING
(2) 2X6 WD. TOP PLATES
HORIZ. CEMEN. SIDING W/ 7" EXP.
R-19 BATT INSULATION
PRE-FIN. MTL. FLASHING
2X4 KDAT WD. TRIM (CHAMFER TO DRAIN)
2X6 KDAT WD. HEAD TRIM
WD. HEADER (SEE STRUCT.)
5 3/4" 1 1/2"
ALUM. CLAD / WD. PATIO DOOR
CEMEN. TRIM (BEYOND)
10X10 ENFINEERED WD. COLUMN
PT. WD. GATE (BEYOND)
GALVANIZED METAL HINGES
SWEEP TYPICAL @ EXT. DOORS
ADA "ROLL-IN" DOOR SILL
1X6 PT. WD. DECK BOARDS
TPO WATER PROOF MEMBRANE
3/4" APA RATED PLYWD. SUBFLOOR
JOIST HANGER
2X6 WD. CEILING JOISTS
1X6 KDAT WD. T&G CEILING
1X6 CEMEN. TRIM
PRE-FIN. MTL. FLASHING
HORIZ. CEMEN. SIDING W/ 7" EXP.
(2) 2X6 WD. TOP PLATES
PRE-FIN. MTL. FLASHING
2X4 KDAT WD. TRIM (CHAMFER TO DRAIN)
2X6 KDAT WD. HEAD TRIM
5 3/4" 1 1/2"
ALUM. CLAD / WD. PATIO DOOR W/
TRANSOM WINDOW
10X10 ENFINEERED WD. COLUMN
PT. WD. GATE (BEYOND)
GALVANIZED METAL HINGES
SWEEP TYPICAL @ EXT. DOORS
2X4 KDAT WD. SILL TRIM
8" 1' - 4" 1/2" 3 1/2"
7 1/2"
5"
4"8"
4"5"
3/4"1' - 4"5/8"
1 1/2"
STANDING SEAM METAL ROOF
1X6 CEMEN. TRIM
2X10 WD. RAFTERS @ 16" O.C. - TYP.
3/4"1' - 4"5/8"
1 1/2"
FIRST FLOOR HT.
PORCH HT.
SECOND FLOOR
B.O. BEAM
1' - 2 7/8"5' - 2 7/8"3' - 9 1/8"8' - 5 7/8"3' - 6 1/8"3"
3' - 5 3/4"
1X3 PT. WD. HORIZ. RAIL MEMBER
1X4 PT. WD. BOTTOM RAIL
1X6 PT. WD. DECK BOARDS
2X WD. SLEEPER (@ SLOPE 1/8" / FT.)
2X KDAT WD. TRIM (CHAMFER TO DRAIN)
KDAT WD. COLUMN BASE TRIM
1X4 CEMEN. TRIM ON 1X10 CEMEN.
TRIM
EXTEND TPO MEMBRANE OVER EDGE
ONTO TPO COATED MTL. FLASHING
1X4 WD. BLOCKING
5/8" APA RATED PLYWD. SHEATHING
WD. BEAM (SEE STRUCT.)
1X12 CEMEN. TRIM
2X WD. FRAMING
1X CEMEN. TRIM
3 1/2"
1" 1 5/8" 3' - 0" 1 5/8" 1 1/2"
10X10 ENGINEERED WD. COLUMN
2X4 PT. WD. GUARDRTAIL CAP
(CHAMFER TO DRAIN)
1X3 PT. WD. HORIZ. RAIL MEMBER
1X1 PT. WD. PICKETS
KDAT WD. COL. CAPITAL TRIM
WD. BEAM (SEE STRUCT.)
1X4 CEMEN. TRIM ON 1X10 CEMEN.
TRIM
1X6 KDAT WD. T&G SOFFIT
1X4 CEMEN. TRIM ON 1X8 CEMEN
TRIM
PRE-FIN. MTL. DRIP EDGE
5/8" APA RATED PLYWD. SHEATHING
ROOFING FELT (# PER ROOFING MANF.)
STANDING SEAM METAL ROOF
2X WD. BLOCKING (CONT.)
10X10 ENGINEERED WD. COLUMN
2X4 PT. WD. GUARDRTAIL CAP
(CHAMFER TO DRAIN)
1X3 PT. WD. HORIZ. RAIL MEMBER
1X1 PT. WD. PICKETS
1X3 PT. WD. HORIZ. RAIL MEMBER
1X4 PT. WD. BOTTOM RAIL
KDAT WD. COLUMN BASE TRIM
FINISHED GRADE
FOUNDATION (SEE STRUCT.)
9"
4"7 1/2"
7 3/4"
4"
1X CEMEN. TRIM
JOIST HANGER
2X8 WD. RAFTERS @
16" O.C. - TYP.
JOIST HANGER
1' - 7 3/8"
5 1/2" 5 1/2"
SECOND FLOOR
5/8" 1' - 4" 3/4" 1 1/2"
3/4"3/4"
2 1/2"
CEMEN. HORIZ. SIDING W/ 7" EXP. - TYP.
5/8" APA RATED PLYWD. SHEATHING
(1) LAYER COMM. BUILDING WRAP
WD. STARTER STRIP (PER SIDING MANF.)
PRE-FIN. METAL FLASHING W/ SEALANT
2X4 KDAT WD. TRIM (ANGLE TO DRAIN)
1X4 CEMEN. TRIM
1X10 CEMEN. TRIM
PRE-FIN. MTL. FLASHING W/ SEALANT
CEMEN. HORIZ. SIDING W/ 7" EXP. - TYP.
WD. RIM JOIST - TYP.
(2) 2X6 WD. TOP PLATES
R-19 BATT INSULATION
6 7/8" 3 1/4"
1 1/2" 3/8"
I SSUE
P ROJECT INFO
S HEET TITLE
D ate
P roject No.
COPYRIGHT 2019 COURT ATKINS GROUP -
THIS DRAWING IS THE PROPERTY OF THE
ARCHITECT AND IS NOT TO BE REPRODUCED IN
WHOLE OR IN PART BY ANY MEANS OR METHOD
WITHOUT THE EXPRESS WRITTEN CONSENT OF THE
ARCHITECT. ANY UNAUTHORIZED
REPRODUCTION OR REUSE OF THESE
DOCUMENTS WILL RESULT IN LEGAL ACTION.
POST OFFICE BOX 3978
BLUFFTON, SC 29910
PH: 843.815.2557
FX: 843.815.2547
WWW.COURTATKINS.COM
©
2/8/2021 11:28:20 AM
2 021.02.08
2 0-0 95
A5.0 O LD VILLAGE SQUARE - B UILDING 5
1 0 MARIANNA WAY
B LUFFTON, SC 29910
D ETAILS
3/4" = 1'-0"A5.0
2 WALL SECTION @ ENTRY GATE
3/4" = 1'-0"A5.0
4 SERVICE YARD DETAIL
N O. REV. DATE DESCRIPTION
3/4" = 1'-0"A5.0
1 WALL SECTION @ TYP. EXT. WALL
3/4" = 1'-0"A5.0
3 WALL SECTION @ TYP. PORCH
1 1/2" = 1'-0"A5.0
5 TYP. WATERTABLE
ATTACHMENT 4
DOOR HEAD HT.
TRANSOM HD. HT.
FIN. FLR.
FIN. FLR.
WIN. HD. HT.
TRANSOM HD. HT. WIN. HD. HT.
EXTERIOR GATE SYSTEM
INSWING GATE
PAIR 2'-8" x 7'-3" (R.O. ±5'-4" x 9'-3")
3/4" X 3/4" PICKETS (PATTERN AS
SHOWN) MANUFACTURER T.B.D. BY
G.C. / OWNER
ADJUST DOOR HEIGHT TO ENSURE
TRUE 9'-0" & 9'-3" ROUGH OPNGS.
- TOP OF DOOR & TANSOMS TO
ALIGN W/ TOP OF ADJACENT DRS.
100
1 3/4"1 3/4"
2' - 10"
2' - 10"
2' - 10"
1 3/4" 1 3/4"
1' - 9"3"4' - 2"2' - 10"
1' - 9"3"4' - 2"2' - 10"
1 3/4" 1 3/4"
1' - 9"3"4' - 5"2' - 10"
1" 1"
1/2" 2" 2" 2" 2" 1/2"
4 1/2" 6' - 8" 2" 1/2"
9' - 3"
7' - 3"
5' - 4"
2' - 8" 2' - 8"
5' - 4"
2' - 8" 2' - 8"
9' - 0"
1/2" 4"4" 1/2" 4" 1/2"4" 4"
3' - 0"
4"5' - 11"8 1/2"
4"4' - 8"4"1' - 4"4"
1 3/4"
1/2" 3 1/2"
1' - 2"
1/2" 3 1/2"
1' - 2"
3' - 0"
1/2"4"5' - 11"8 1/2"
4"6' - 0"8"
1/2" 3 1/2"
1' - 2"
3' - 0" SEE SCHED.
SEE SCHEDULE
SEE SCHED.
SEE SCHEDULE
EXTERIOR DOOR SYSTEM
OUTSWING DOOR
PAIR 2'-8" x 7'-0" (R.O. ±5'-4" x 9'-0")
SDL MUNTINS W/ SPACE BAR
(PATTERN AS SHOWN) MANUF. T.B.D.
BY G.C. / OWNER
DP RATING 50 OR APPROVED EQ.
ADJUST DOOR HEIGHT TO ENSURE
TRUE 9'-0" & 9'-3" ROUGH OPNGS.
- TOP OF DOOR & TRANSOMS TO
ALIGN W/ TOP OF ADJACENT DRS.
103A
7' - 0"
7' - 0"
7' - 0"
104B
EXTERIOR DOOR SYSTEM
OUTSWING DOOR
3'-0" x 7'-0" (R.O. ±3'-0" x 9'-0")
SDL MUNTINS W/ SPACE BAR
(PATTERN AS SHOWN) MANUF. T.B.D.
BY G.C. / OWNER
DP RATING 50 OR APPROVED EQ.
ADJUST DOOR HEIGHT TO ENSURE
TRUE 9'-0" & 9'-3" ROUGH OPNGS.
- TOP OF DOOR & TRANSOMS TO
ALIGN W/ TOP OF ADJACENT DRS.
103
104
9' - 0"
EXTERIOR DOOR SYSTEM
OUTSWING DOOR
3'-0" x 7'-0" (R.O. ±3'-0" x 7'-0")
MANUF. T.B.D. BY G.C. / OWNER
DP RATING 50 OR APPROVED EQ.
ADJUST DOOR HEIGHT TO ENSURE
TRUE 7'-0" ROUGH OPNGS.
- TOP OF DOOR & TRANSOMS TO
ALIGN W/ TOP OF ADJACENT DRS.
101
102
EXTERIOR DOOR SYSTEM
OUTSWING DOOR
3'-0" x 7'-0" (R.O. ±3'-0" x 7'-0")
SDL MUNTINS W/ SPACE BAR
(PATTERN AS SHOWN)
MANUF. T.B.D. BY G.C. / OWNER
DP RATING 50 OR APPROVED EQ.
ADJUST DOOR HEIGHT TO ENSURE
TRUE 7'-0" ROUGH OPNGS.
- TOP OF DOOR & TRANSOMS TO
ALIGN W/ TOP OF ADJACENT DRS.
301D
302D
INTERIOR DOOR SYSTEM
SOLID CORE WOOD
2 PANEL
MANUF. T.B.D. BY G.C. / OWNER
SEE SCHEDULE FOR
ADDITIONAL INFORMATION
INTERIOR DOOR SYSTEM
SOLID CORE WOOD
2 PANEL - DOUBLE
MANUF. T.B.D. BY G.C. / OWNER
SEE SCHEDULE FOR
ADDITIONAL INFORMATION
1/2"4' - 1 1/2"2' - 10"
4 1/2" 6' - 5" 2 1/2"
7' - 0"
5' - 4"
2' - 8" 2' - 8"
1" 1"
EXTERIOR GATE SYSTEM
INSWING GATE
PAIR 2'-8" x 7'-0" (R.O. ±5'-4" x 7'-0")
3/4" X 3/4" PICKETS (PATTERN AS
SHOWN) MANUFACTURER T.B.D. BY
G.C. / OWNER
ADJUST DOOR HEIGHT TO ENSURE
TRUE 9'-0" & 9'-3" ROUGH OPNGS.
- TOP OF DOOR & TANSOMS TO
ALIGN W/ TOP OF ADJACENT DRS.
100
2' - 0"7' - 0"3"
4" 2' - 4" 4" 3' - 8" 4"
7' - 0"
1 3/4"
2' - 10"
1 2 3 4 5 6 8 9
4' - 2"2' - 10"
1 3/4" 1 3/4"
1/2" 4"4" 1/2" 4" 1/2"4" 4"
1/2"4"5' - 11"8 1/2"
7' - 0"
2' - 8" 2' - 8"
5' - 4"
EXTERIOR DOOR SYSTEM
OUTSWING DOOR
PAIR 2'-8" x 7'-0" (R.O. ±5'-4" x 7'-0")
SDL MUNTINS W/ SPACE BAR
(PATTERN AS SHOWN) MANUF. T.B.D.
BY G.C. / OWNER
DP RATING 50 OR APPROVED EQ.
ADJUST DOOR HEIGHT TO ENSURE
TRUE 7'-0" ROUGH OPNGS.
- TOP OF DOOR & TRANSOMS TO
ALIGN W/ TOP OF ADJACENT DRS.
103
7
SEE SCHED.
SEE SCHEDULE
SLIDE SLIDE
INTERIOR DOOR SYSTEM
SOLID CORE WOOD
2 PANEL - DOUBLE
MANUF. T.B.D. BY G.C. / OWNER
SEE SCHEDULE FOR
ADDITIONAL INFORMATION
10
1' - 6" 5' - 6" 3" 1' - 9"
9' - 0"
2' - 8"
1"
5' - 6"
1"
1' - 4"1' - 4"7' - 6"
2' - 8"4' - 4"
2' - 8"
4' - 4"
7' - 0"
2' - 8"
1"
2' - 8"
2' - 8"4' - 4"
1' - 4"
1"
2' - 8"
1"
1' - 4"
5' - 0"2' - 0"
7' - 0"
7' - 0"
2' - 8"
4' - 8"3'-1" ALF
7 '-9" ABOVE LOFT FLOOR
FIN. FLOOR
KDAT WD. SHUTTERS
WROUGHT IRON
SHUTTER DOG
WROUGHT IRON
SHUTTER DOG
WROUGHT IRON
SHUTTER DOG
KDAT WD. SHUTTER KDAT WD. SHUTTER
WROUGHT IRON
SHUTTER DOG
KDAT WD. SHUTTERS
CLAD DOUBLE HUNG UNITS
2'-8" x 5'-6" (R.O. ± 2'-8" x 7'-6")
SDL MUNTINS W/ SPACER BAR
(PATTERN AS SHOWN)
MANUF. T.B.D. BY G.C. / OWNER
DP RATING 50 OR APPROVED EQUAL
A
CLAD PICTURE UNITS
2'-8" x 2'-8" (R.O. ± 2'-8" x 2'-8")
SDL MUNTINS W/ SPACER BAR
(PATTERN AS SHOWN)
MANUF. T.B.D. BY G.C. / OWNER
DP RATING 50 OR APPROVED EQUAL
B
CLAD CASEMENT UNITS
2'-8" x 2'-8" (R.O. ± 2'-8" x 2'-8")
SDL MUNTINS W/ SPACER BAR
(PATTERN AS SHOWN)
MANUF. T.B.D. BY G.C. / OWNER
DP RATING 50 OR APPROVED EQUAL
C
CLAD CASEMENT UNITS
2'-8" x 2'-8" (R.O. ± 2'-8" x 2'-8")
SDL MUNTINS W/ SPACER BAR
(PATTERN AS SHOWN)
MANUF. T.B.D. BY G.C. / OWNER
DP RATING 50 OR APPROVED EQUAL
D
CLAD DOUBLE HUNG UNITS
2'-8" x 5'-0" (R.O. ± 2'-8" x 5'-0")
SDL MUNTINS W/ SPACER BAR
(PATTERN AS SHOWN)
MANUF. T.B.D. BY G.C. / OWNER
DP RATING 50 OR APPROVED EQUAL
E
CLAD DOUBLE HUNG UNITS
2'-8" x 4'-8" (R.O. ± 2'-8" x 4'-8")
SDL MUNTINS W/ SPACER BAR
(PATTERN AS SHOWN)
MANUF. T.B.D. BY G.C. / OWNER
DP RATING 50 OR APPROVED EQUAL
F
9' - 0"
7' - 0"
1' - 4"
1"
2' - 8"
1"
1' - 4"2 1/2" 1/2"
1/2"1/2"
2 1/2"
2 3/4"
3/4"
VARIES 1" 2 3/4"VARIES1"VARIES
EQ EQ
2 1/2" VARIES 2 1/2" VARIES 2 1/2" VARIES 2 1/2"
VARIES
2 1/2"1/2"
1 1/2"
5 3/4" 1 1/2"
1 1/2"
2"
2X KDAT WD. HEAD TRIM
(CHAMFER TO DRAIN)
1X CEMEN. HEAD TRIM
IRON HINGES (BEYOND)
1X KDAT WD. STILE
1/2" X 1/4" KDAT WD. FLAT STOCK
1/4" KDAT WD. PANEL
1X KDAT WD. RAIL
1/4" KDAT WD. PANEL
1/2" X 1/4" KDAT WD. FLAT STOCK
IRON HINGES (BEYOND)
1X KDAT WD. STILE
IRON SHUTTER DOG
1X KDAT WD. RAIL 2X WD. SILL (CHAMFER TO DRAIN
ALUM. CLAD /WD. DIOUBLE HUNG
WINDOW
1X KDAT WD. TRIM
1X KDAT WD. RAIL
1X KDAT WD. TRIM
7/8" 1 3/4" 2" 1/2"
1/2"
1/4" 1/4"
5 1/8"
1 1/8"
SCROLLED END
POWDERCOATED STL.
SHUTTER DOG
SCROLLED END
POWDERCOATED FASTENER
& HARDWARE
1/2"
1"
2 3/4" 2 1/2"
I SSUE
P ROJECT INFO
S HEET TITLE
D ate
P roject No.
COPYRIGHT 2019 COURT ATKINS GROUP -
THIS DRAWING IS THE PROPERTY OF THE
ARCHITECT AND IS NOT TO BE REPRODUCED IN
WHOLE OR IN PART BY ANY MEANS OR METHOD
WITHOUT THE EXPRESS WRITTEN CONSENT OF THE
ARCHITECT. ANY UNAUTHORIZED
REPRODUCTION OR REUSE OF THESE
DOCUMENTS WILL RESULT IN LEGAL ACTION.
POST OFFICE BOX 3978
BLUFFTON, SC 29910
PH: 843.815.2557
FX: 843.815.2547
WWW.COURTATKINS.COM
©
2/8/2021 11:28:26 AM
2 021.02.08
2 0-0 95
A6.0 O LD VILLAGE SQUARE - B UILDING 5
1 0 MARIANNA WAY
B LUFFTON, SC 29910
D OOR AND
W INDOW
S CHEDULE
WINDOW SCHEDULE
TYPE
MARK WINDOW TYPE DESCRPITION
R.O. HEAD
HEIGHT
DESIGN
PRESSURE COMMENTSWIDTH HEIGHT
A CLAD DOUBLE HUNG UNIT 2'-8" x 5'-0" 2' - 8" 7' - 6" 9' - 0"
B CLAD TRANSOM UNIT 2'-8" x 2'-8" 2' - 8" 2' - 8" 7' - 0 "
C CLAD CASEMENT UNIT 2''-8" x 2'-8" 2' - 8" 2' - 8" 7' - 0"
D CLAD CASEMENT UNIT 2''-8" x 2'-8" 2' - 8" 2' - 8" 7' - 0"
E CLAD DOUBLE HUNG UNIT 2'-8" x 5'-0" 2' - 8" 5' - 0" 7' - 0"
F CLAD DOUBLE HUNG UNIT 2'-8" x 4'-8" 2' - 8" 4' - 8" 7' - 9"
DOOR SCHEDULE
NO. ROOM WIDTH HEIGHT
DOOR FRAME HARDWARE
COMMENTSTYPE MATERIAL FINISH RATED MAT'L
FINIS
H RATED LOCK CLOSER STOP PANIC MISC
201F CLOSET 1 4' - 0" 7' - 0" 9 SOLID CORE MDF PTD. WD. PTD . PASSAGE
201G BATHROOM 1 2' - 6" 7' - 0" 8 SOLID CORE MDF PTD. WD. P TD. PRIVACY X
201H LAUNDRY 4' - 0" 7' - 0" 9 SOLID CORE MDF PTD. WD. PTD. PASSAGE
202 KITCHEN, LIVING & DINING 3' - 0" 7' - 0" 6 ALUM. CLA D / WD. F.A.F. WD. F.A.F. ENTRY X
202A OPEN AIR PORCH 5' - 4" 7' - 0" 7 ALUM. CLAD / WD. F. A.F. WD. F.A.F. ENTRY
202B KITCHEN, LIVING & DINING 2' - 8" 6' - 11 1/2" 8 SOL ID CORE MDF PTD. WD. PTD. PRIVACY X
202C BEDROOM 2 4' - 0" 7' - 0" 9 SOLID CORE MDF PTD. WD. PT D. PASSAGE
202D VESTIBULE 2 2' - 6" 7' - 0" 8 SOLID CORE MDF PTD. WD. PTD. PRIVACY X
202E VESTIBULE 2 2' - 8" 7' - 0" 8 SOLID CORE MDF PTD. WD. PTD. PRIVACY X
202F VESTIBULE 1 4' - 0" 7' - 0" 9 SOLID CORE MDF PTD. WD. PTD. PASSAGE
202G VESTIBULE 1 2' - 6" 7' - 0" 8 SOLID CORE MDF PTD. WD. PTD. PRIVACY X
202H KITCHEN, LIVING & DINING 4' - 0" 7' - 0" 9 SOLID CO RE MDF PTD. WD. PTD. PASSAGE
301 LANDING 3' - 0" 7' - 0" 6 ALUM. CLAD / WD. F.A.F. WD. F .A.F. SECURITY
301A KITCHEN, DINING & LIVING 5' - 0" 7' - 0" 9 SOLID CO RE MDF PTD. WD. PTD. PASSAGE
301B KITCHEN, DINING & LIVING 2' - 8" 7' - 0" 9 SOLID CO RE MDF PTD. WD. PTD. PRIVACY X
301C BEDROOM 2 4' - 0" 7' - 0" 10 SOLID CORE MDF PTD. WD. P TD. PRIVACY
301D BALCONY 3' - 0" 7' - 0" 6 ALUM. CLAD / WD. F.A.F. WD. F.A.F. ENTRY
301E KITCHEN, DINING & LIVING 2' - 6" 7' - 0" 8 SOLID CO RE MDF PTD. WD. PTD. PRIVACY X
301F BEDROOM 1 2' - 8" 7' - 0" 8 SOLID CORE MDF PTD. WD. PT D. PRIVACY X
301G CLOSET 1 6' - 0" 7' - 0" 10 SOLID CORE MDF PTD. WD. PT D. PASSAGE
302 KITCHEN, DINING & LIVING 3' - 0" 7' - 0" 6 ALUM. CLA D / WD. PTD. WD. F.A.F. SECURITY
302A LAUNDRY 5' - 0" 7' - 0" 9 SOLID CORE MDF PTD. WD. PTD. PASSAGE
302B BEDROOM 2 2' - 8" 7' - 0" 9 SOLID CORE MDF PTD. WD. PT D. PRIVACY X
302C CLOSET 2 4' - 0" 7' - 0" 10 SOLID CORE MDF PTD. WD. PT D. PRIVACY
302D BALCONY 3' - 0" 7' - 0" 6 ALUM. CLAD / WD. F.A.F. WD. F.A.F. ENTRY
302E BATHROOM 2' - 6" 7' - 0" 8 SOLID CORE MDF PTD. WD. PTD . PRIVACY X
302F KITCHEN, DINING & LIVING 2' - 8" 7' - 0" 8 SOLID CO RE MDF PTD. WD. PTD. PRIVACY X
302G BEDROOM 1 6' - 0" 7' - 0" 10 SOLID CORE MDF PTD. WD. P TD. PASSAGE
DOOR SCHEDULE
NO. ROOM WIDTH HEIGHT
DOOR FRAME HARDWARE
COMMENTSTYPE MATERIAL FINISH RATED MAT'L
FINIS
H RATED LOCK CLOSER STOP PANIC MISC
100 ENTRY PORCH 5' - 4" 9' - 3" 1 WROUGHT IRON PWDR. COAT WD. PTD. ENTRY X
101 ELEC. RM. 3' - 0" 7' - 0" 5 HOLLOW MTL. PTD. H.M. PTD. S ECURITY
102 FIRE RISER 3' - 0" 7' - 0" 5 HOLLOW MTL. PTD. H.M. PTD. SECURITY
103 KITCHEN / DINING & LIVING 3' - 0" 9' - 0" 4 ALUM. CL AD / WD. F.A.F. WD. F.A.F. ENTRY X
103A OPEN AIR PORCH 5' - 4" 9' - 0" 3 ALUM. CLAD / WD. F. A.F. WD. F.A.F. SECURITY
103B BUSINESS OFFICE 3' - 0" 7' - 0" 6 ALUM. CLAD / WD. F .A.F. WD. F.A.F. SECURITY
103C CLOSET 2 3' - 6" 7' - 0" 9 SOLID CORE MDF PTD. WD. PTD . PASSAGE
103D BUSINESS OFFICE 2' - 6" 7' - 0" 8 SOLID CORE MDF PTD . WD. PTD. PRIVACY X
103E BEDROOM 1 2' - 8" 7' - 0" 8 SOLID CORE MDF PTD. WD. PT D. PRIVACY X
103F CLOSET 1 4' - 0" 7' - 0" 9 SOLID CORE MDF PTD. WD. PTD . PASSAGE
103G BATHROOM 1 2' - 6" 7' - 0" 8 SOLID CORE MDF PTD. WD. P TD. PRIVACY X
103H LAUNDRY 4' - 0" 7' - 0" 9 SOLID CORE MDF PTD. WD. PTD. PASSAGE
104 KITCHEN / DINING & LIVING 3' - 0" 9' - 0" 4 ALUM. CL AD / WD. F.A.F. WD. F.A.F. ENTRY X
104A OPEN AIR PORCH 5' - 4" 9' - 0" 3 ALUM. CLAD / WD. F. A.F. WD. F.A.F. ENTRY
104B KITCHEN / DINING & LIVING 2' - 8" 6' - 11 1/2" 8 SO LID CORE MDF PTD. WD. PTD. PRIVACY X
104C BEDROOM 2 4' - 0" 7' - 0" 9 SOLID CORE MDF PTD. WD. PT D. PASSAGE
104D VESTIBULE 1 2' - 6" 7' - 0" 8 SOLID CORE MDF PTD. WD. PTD. PRIVACY X
104E VESTIBULE 1 2' - 8" 7' - 0" 8 SOLID CORE MDF PTD. WD. PTD. PRIVACY X
104F VESTIBULE 2 4' - 0" 7' - 0" 9 SOLID CORE MDF PTD. WD. PTD. PASSAGE
104G VESTIBULE 2 2' - 6" 7' - 0" 8 SOLID CORE MDF PTD. WD. PTD. PRIVACY X
104H KITCHEN / DINING & LIVING 4' - 0" 7' - 0" 9 SOLID C ORE MDF PTD. WD. PTD. PASSAGE
200 COMMUNITY PORCH 5' - 4" 7' - 0" 2 WROUGHT IRON PWDR. COAT WD. PTD. PASSAGE
201 KITCHEN, LIVING & DINING 3' - 0" 7' - 0" 6 ALUM. CLA D / WD. F.A.F. WD. F.A.F. ENTRY X
201A OPEN AIR PORCH 5' - 4" 7' - 0" 7 ALUM. CLAD / WD. F. A.F. WD. F.A.F. ENTRY
201B BEDROOM 2 2' - 8" 6' - 11 1/2" 8 SOLID CORE MDF PTD. WD. PTD. PRIVACY X
201C CLOSET 2 4' - 0" 7' - 0" 9 SOLID CORE MDF PTD. WD. PTD . PASSAGE
201D BATHROOM 2 2' - 6" 7' - 0" 8 SOLID CORE MDF PTD. WD. P TD. PRIVACY X
201E BEDROOM 1 2' - 8" 7' - 0" 8 SOLID CORE MDF PTD. WD. PT D. PRIVACY X
NO. REV. DATE DESCRIPTION
3/4" = 1'-0"A6.0
1 TYPICAL WINDOW ELEVATION
3" = 1'-0"A6.0
2 SHUTTER DOG DETAIL
ATTACHMENT 4
UP
UP
UP
PLANTING PLAN -
PHASE 02
L501
SITE DEVELOPMENT PLANS
FOR
6 SHULTS ROAD
BLUFFTON, SOUTH CAROLINA
DRAWING NUMBER
DRAWING TITLE
DESIGN CONCEPTS, DRAWING, SHEETS,
LOGOS, SPECIFICATIONS, DETAILS,
WRITTEN MATERIAL SHALL NOT BE USED
OR REPRODUCED IN WHOLE OR IN PART
IN ANY FORM WITHOUT PRIOR WRITTEN
CONSENT OF WJK LTD.
© 2020 WJK LTD.
THIS SHEET TO SCALE AT: 24"X36"
DATE:
PROJECT NO.:
DRAWN BY:
CHECKED BY:
FEB 22, 2021
20106.01
JM
DK
REVISIONS:
c
N
EW
010203040
5152535
Scale 1 " = 10'
PHASE 02 (BUILDINGS 3, 4, 5) PLANT SCHEDULE:
EXISTING LIVE OAK
TO REMAIN, TYP.
15 MUHC
20 TRAA
MATCHLINE L500
PHASE 02 L.O.W.
PHASE 02 L.O.W.
1 QUEV
MATCHLINE L501
PHASE 02 L.O.W.
TREE CANOPY COVERAGE:
CANOPY COVERAGE SUMMARY
COVERAGE (SF) DESCRIPTION
SITE AREA (PHASE 02)
BUILDING FOOTPRINT
REMAINING SITE AREA
MATURE CANOPY COVERAGE
PROVIDED
(EXISTING AND PROPOSED)
39,112
6,000
33,112
25,692
% CANOPY COVERAGE (75% MIN.)78%
CANOPY COVERAGE
OF EXISTING AND
PROPOSED TREES
(GREEN SHADED AREA)
1 ILEO
5 VIBO
1 QUEV
40 TRAA
1 QUEV
50 JUNE
1 MAGG
15 SPAB
5 AZAE
1 LAGN
1 ILEO
10 VIBO
5 DIEB
1 LAGN
3 DIEB
7 ILVN
5 VIBS
BUILDING
5
ACCESSIBLE PARKING
5 PLUA
5 PLUA
3 VIBS
1 SABP
ATTACHMENT 5
PLAN REVIEW COMMENTS FOR COFA-01-21-014894
Town of Bluffton
Department of Growth Management
20 Bridge Street P.O. Box 386 Bluffton, South Carolina 29910
Telephone 843-706-4522
OLD TOWN
Plan Type: Apply Date:
Plan Status: Plan Address: 10 Marianna Way Way
BLUFFTON, SC 29910
Historic District
Active
01/11/2021
Plan PIN #:Case Manager: R610 039 000 0746 0000Katie Peterson
Plan Description: A request by Court Atkins Architects, on behalf of the owner, Herkus, LLC, for review of a Certificate of
Appropriateness to allow the construction of a new 2 1/2 -story multifamily residential building of
approximately 5,328 SF located at 10 Marianna Way, Building 5 in the Old Village Square development, in the
Old Town Bluffton Historic District and zoned Neighborhood General – HD.
STATUS [1-12-2021]: The application received 1-11-2021 is currently being reviewed by Staff for
conformance with the Unified Development Ordinance (UDO), Traditional Construction Patterns, and any
development plans associated with the parcel and is scheduled for review by the HPRC at the 1-20-2021
meeting. Please note all comments provided at this meeting reflect the 1-11 submittal and do not take into
consideration the revised drawings submitted 1-19-2021.
Staff Review (HD)
Submission #: 1 Recieved: 01/15/2021 Completed: 01/19/2021
Reviewing Dept. Complete Date StatusReviewer
Revisions Required01/19/2021Growth Management Dept Review
(HD)
Katie Peterson
Comments:
01/19/2021 Page 1 of 3
1. Multifamily is not a permitted use in the Neighborhood General – HD zoning district. The plan proposes a multi-family structure.
Revise use to one permitted by the UDO. (4.3)
2. Applicants are required to provide notice via certified mail to all owners of property, including any Property Owners Association
(POA) abutting, adjacent or contiguous to the property that is subject of the application within fifteen (15) days of the UDO
Administrator’s acceptance of a completed application. Upon submittal of the Final Application, a list of adjacent property owners
and a letter template will be sent. (3.2.4.)
3. At time of final submittal the following fields on the application must be updated: address is 6 Marianna Way, as this is a new
application, there are no previous applications and all fields must be completed, the existing square footage is 0, the plans must be
printed to scale. (Applications Manual)
4. This structure will be reviewed as an Additional Building Type. The proposed structure most closely meets the characteristics of
the Mansion Apartment House (use, size, number of units, appearance, defined central primary entrance, center hall in format),
however does not meet all of the characteristics (no full-length shared porch, exceeds width, unit SF slightly under). It does not
meet the characteristics of a Center Hall House (does not meet use, max SF, have side or rear wings secondary to the mass and
exceeds typical width), with the exception of the footprint. Mansion Apartment House building types are not permitted in the NG-HD
zoning district, however, this structure would be reviewed as an Additional Building Type with characteristics of the Mansion
Apartment House. *Note: the building type may be altered when the use and other architectural standards are updated.
5. Overall building proportions and individual building features shall have a proportional relationship with one another, as well as the
overall building form. The central portico appears under-scaled relative to the overall width of both buildings. Additionally, the glazing
on the rear elevations appears to have under-scaled glazing resulting in large areas of blank walls. (Sec. 5.15.5.F.4.a.)
6. Residential structures shall have a first finished floor height raised a minimum of three (3) feet above average adjacent sidewalk
grade. *Note: See comment 1 (5.15.5.F.1.c.)
7. Porches shall be a minimum of 6’ in depth. The side porches on the first floor are 5’ deep. The depth must be increased to meet
the minimum depth requirement. *Note: See comment 1 (5.15.6.E.5.a)
8. Porch height shall be 30” minimum from grade to top of stairs. The porches are currently proposed at grade and must be raised to
no less than 30”. *Note: See comment 1 (5.15.6.E.5.c.)
9. The Architectural standards encourage Bluffton vernacular architecture and construction which is straightforward and functional,
and which draws its ornament and variety from the traditional assembly of genuine materials. The porches on either side of the
second floor do not have any access and are not functional. Provide access or reconfigure the ends of the structure to a more
traditional configuration. (5.15.6.A.)
10. Doors are permitted to be wood, metal or metal-clad. The door schedule lists doors 101 and 102, located on the rear exterior
elevation, as insulated fiberglass. The door material must be revised to a permitted material (5.15.6.I.2.b.)
11. Roofs are permitted to be gabled, hipped, and shed. The structure proposes the use of a half-hipped roof. A determination on
the appropriateness of this alternate roof shape is required prior to approval. (5.15.6.J.1.a.)
12. Rooflines shall be simple, utilizing gables, hips, and sheds, or combinations of these basic forms. Roofs shall correspond to the
major massing of the building; roof forms that overwhelm the mass of the primary building form and complicated rooflines are to be
avoided. As the proposed structure incorporates hip, gable, half-gable and shed roofs, the number of roof profiles is complicated by
the number of materials proposed on the structure. Consider revising the roofing material to be single material. (5.15.5.F.2.b.)
13. The Old Town Bluffton Historic District embodies a diverse community character. Structures range from stately homes, unique
shops, historic structures nestled among new construction infill. The proposed building plans for 6 and 10 Marianna Way are
identical This is not representative of the architectural diversity of Old Town Bluffton Historic District, nor does this exist elsewhere
within the District. Building elements should be reconsidered to introduce variation while maintaining consistency with the general
character of the surrounding area. In order to ensure consistency with the existing nature and character of the surrounding area,
elements of the buildings should be revised to maintain the same general character of the development while introducing variation
into the design. (3.18.3.D.)
14. For the final application provide architectural details of the railings and balusters, corner board trim, water table detail, shutter
dog profile, and a wall section through the eave depicting the material configuration and dimensions and a revised Landscape Plan
as the footprint configuration has changed. (Applications Manual)
15. Additional comments may be provided at the HPRC meeting based off of discussion.
Approved with Conditions01/19/2021Addressing Review Nick Walton
Comments:
1. 10 Marianna Way.
Approved with Conditions01/19/2021Beaufort Jasper Water and Sewer
Review
James Clardy
Comments:
1. The project is under construction, pending issuance of the close-out and permit to operate.
Approved with Conditions01/19/2021Building Safety Review Richard Spruce
Comments:
1. For Type V construction, building walls located 10 feet or less from the property line must be 1 hour rated.
Approved with Conditions01/19/2021HPRC Review Katie Peterson
Comments:
01/19/2021 Page 2 of 3
1. Service yards are to be located in a rear or side yard location not facing a street and away from all public vantage. As the service
yard will be visible from a public vantage on all elevations, special consideration shall be given to the screening of the service yard.
Additionally, provide location of electric meters. (5.15.5.10.)
2. A space under a sloping roof that has the line of intersection of the roof and the exterior wall supporting the roof not more than 3
feet above the floor level, and in which space the possible floor area with head room of 5 feet or more occupies between 30 and 70
percent of the total floor area of the story directly beneath. If the possible floor area with head room of 5 feet or more occupies more
than 70 percent of the total floor area of the story directly beneath, then that space shall be considered a full story. The third story
appears to have significant area which has possible floor area with head room of 5 feet or more which has not been included in the
SF calculations. The square footage calculations will need to be updated to reflect this calculation.
Additionally, there are discrepancies between the SF labels within the rooms, the narrative, and the leader line calculations (the
coversheet is missing the numbers). While it is expected that the leader lines and room labels will vary slightly (interior vs exterior
wall measurements), the room labels and leader line calculations exceed 70% of the floor beneath and would constitute a 3rd story.
(5.15.5.F.1.e.)
Approved with Conditions01/19/2021Transportation Department Review
- HD
William Howard
Comments:
1. No Comment.
Approved01/19/2021Watershed Management Review William Baugher
Comments:
1. See DPA-06-17-011010.
Plan Review Case Notes:
01/19/2021 Page 3 of 3
1
Katie Peterson
From: Jack Trenta <jacktrenta@verizon.net>
Sent: Thursday, February 18, 2021 5:51 PM
To: 'Jen Sommerville'
Cc: Katie Peterson; Daniel Keefer; 'Andrea Eldred'
Subject: RE: Landscape and construction plans for new construction - 22 Stock Farm Road -
Approved by POA
WARNING!
This email originated from outside of the Town of Bluffton's email system. DO NOT click any links or open any
attachments unless you recognize the sender and know the content is safe.
Hi Jen,
The construction plans and landscape plan have been approved by the Stock Farm POA. The only concern
is tree removal. The next time you’re going to be over this way let me know as I’d like to walk the lot with
you and have you clarify which trees will remain. We’d naturally like to retain as much of the tree canopy
along Stock Farm Road as possible. And we need to retain all possible vegetation and plantings along the
street side of the sidewalk. I may get Dan Keefer to join us as well.
And we absolutely want you or David to be here the day the site prep and clearing is to occur. And please
let me know when that will be when you know, so myself or Dan or Andrea can be there so we can all be
on the same page as to what goes and what stays. We’ve had a couple of bad experiences with the “now
you see it and now you don’t” and by then it’s too late.
My best to Shea and Ida!
Jack Trenta
Broker Associate
703-338-9529
jacktrenta@verizon.net
https://www.century21.com/agent/jack.trenta@century21.com
38B New Orleans Rd • Hilton Head • SC • 29928
www.century21diamondrealty.com
From: Jen Sommerville <jen@dhabney.com>
Sent: Tuesday, February 09, 2021 1:27 PM
2
To: Jack Trenta <jacktrenta@verizon.net>
Subject: Landscape plans for new construction
Hello Jack,
Please see attached for the landscape plans for the Brancato residence at 22 Stock Farm Road. I think I had already sent
the building plans for your review, let me know if you need them.
Thank you :)
-Jen Sommerville
D.H. ABNEY COMPANY INC.
Licensed General Contractor
Commercial & Residential Construction
License Number: G118163
DHAbney.com
Bluffton, SC 29910
Please consider the environment before printing this e-mail
Notice: This e-mail message is for the sole use of the intended recipient(s) and may contain confidential and
privileged information. Any unauthorized review, use, disclosure or distribution is prohibited. If you are not the
intended recipient, please contact the sender by reply e-mail and destroy all copies of the original message. Please
virus check all attachments to prevent widespread contamination and corruption of files and operating systems. The
unauthorized access, use, disclosure, or distribution of this email may constitute a violation of the Federal Electronic
Communications Privacy Act of 1986 and similar state laws. This communication does not reflect an intention by the
sender or the sender's client or principal to conduct a transaction or make any agreement by electronic means.
Nothing contained in this message or in any attachment shall satisfy the requirements for a writing, and nothing
contained herein shall constitute a contract or electronic signature under the Electronic Signatures in Global and
National Commerce Act, any version of the Uniform Electronic Transactions Act or any other statute governing
electronic transactions.
Source: Town of Bluffton website. First collected Oct 14, 2026.