RecordWell Data

Historic Preservation Commission (PDF)

Town of Bluffton · Beaufort County · meeting of Feb 3, 2021 · Agendas

Open the original document More from Town of Bluffton

Text

Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.

TOWN OF BLUFFTON HISTORIC PRESERVATION COMMISSION ELECTRONIC MEETING Wednesday, February 3, 2021 6:00p.m. PUBLIC COMMENT Public comments will be received via conference line provided by Staff. All requests for public hearing or public comment will be accepted up to two (2) hours prior to the scheduled meeting start time. This meeting can be viewed on the Town of Bluffton’s Facebook page https://www.facebook.com/TownBlufftonSC/ I. CALL TO ORDER II. ROLL CALL III. NOTICE REGARDING ADJOURNMENT The Historic Preservation Commission will not hear new items after 9:30 p.m. unless authorized by a majority vote of the Commission Members present. Items which have not been heard before 9:30 p.m. may be continued to the next regular meeting or a special meeting date as determined by the Commission Members. IV. NOTICE REGARDING PUBLIC COMMENTS* Every member of the public who is recognized to speak shall address the Chairman and in speaking, avoid disrespect to Commission, Staff, or other members of the Meeting. State your name and address when speaking for the record. COMMENTS ARE LIMITED TO THREE (3) MINUTES. V. ADOPTION OF AGENDA VI. ADOPTION OF MINUTES – January 6, 2021 VII. ELECTION OF OFFICERS – Election for vice-chair and Historic Preservation Review Committee Member VIII. PUBLIC COMMENTS FOR ITEMS NOT ON THE AGENDA* IX. OLD BUSINESS X. NEW BUSINESS Town of Bluffton Historic Preservation Commission Agenda February 3, 2021 Page 2 A. Certificate of Appropriateness: A request by Ansley Manuel, on behalf of the owner, Patricia Ellen Malphrus, for approval of a Certificate of Appropriateness to allow an addition of approximately 2,971 SF to the existing single-family structure of approximately 1,095 SF located at 114 Pritchard Street in the Old Town Bluffton Historic District and zoned Neighborhood Conservation-HD. (COFA- 12-20-014811) (Staff-Katie Peterson) B. Certificate of Appropriateness: A request by Court Atkins Architects, on behalf of the owner, Herkus, LLC, for approval of a Certificate of Appropriateness to allow the construction of a new 2 1/2 -story Mixed-Use building of approximately 5,272 heated square feet located at 6 Marianna Way, Building 4 in the Old Village Square development, in the Old Town Bluffton Historic District and zoned Neighborhood General – HD. (Staff-Katie Peterson)(COFA-01-21- 014892) XI. DISCUSSION No discussion. XII. ADJOURNMENT NEXT MEETING DATE– Wednesday, March 3, 2021 * Public Comments may be submitted electronically via the Town’s website at (https://bit.ly/TOBPublicComment ) or by emailing your comments to the Growth Management Coordinator at dmclain@townofbluffton.com. Comments will be accepted up to 2 hours prior to the scheduled meeting start time. All comments will be read aloud for the record and will be provided to the Historic Preservation Committee. “FOIA Compliance – Public notification of this meeting has been published and posted in compliance with the Freedom of Information Act and the Town of Bluffton policies.” In accordance with the requirements of Title II of the Americans with Disabilities Act of 1990 ("ADA"), the Town of Bluffton will not discriminate against qualified individuals with disabilities on the basis of disability in its services, programs, or activities. EXECUTIVE SESSION - The public body may vote to go into executive session for any item identified for action on the agenda. Any person requiring further accommodation should contact the Town of Bluffton ADA Coordinator at 843.706.4500 or adacoordinator@townofbluffton.com as soon as possible but no later than 48 hours before the scheduled event. Town of Bluffton  Historic Preservation Commission Page 1 of 6 January 6, 2021 TOWN OF BLUFFTON HISTORIC PRESERVATION COMMISSION Electronic Meeting Wednesday, January 6, 2021, Minutes Present: Bruce Trimbur - Chair; Courtney McNeil; Michael Lovecchio; Jesse Solomon, Mary Vaux Bell, and Kerri Schmelter Staff: Katie Peterson, Senior Planner; Kevin Icard, Planning and Community Development Manager; Charlotte Moore, Principal Planner; and, Darby McLain, Growth Management Coordinator I. CALL TO ORDER Chairman Trimbur called the meeting to order at 6:00 p.m. II. ROLL CALL All members were present. III. NOTICE REGARDING ADJOURNMENT The Historic Preservation Commission will not hear new items after 9:30 P.M. unless authorized by a majority vote of the Commission Members present. Items which have not been heard before 9:30 P.M. may be continued to the next regular meeting or an additional meeting date as determined by the Commission members. IV. NOTICE REGARDING PUBLIC COMMENTS Every member of the public who is recognized to speak shall address the Chairman and in speaking, avoid disrespect to the Commission, Town Staff, and other members of the meeting. State your name and address when speaking for the record. UNLESS OTHERWISE AMENDED BY THE HISTORIC PRESERVATION COMMISSION, COMMENTS ARE LIMITED TO THREE (3) MINUTES. V. ADOPTION OF THE AGENDA Commissioner McNeil made a motion to adopt the agenda. Commissioner Solomon seconded the motion. All were in favor and the motion passed. VI. ADOPTION OF MINUTES Commissioner Adams made a motion to adopt the December 2, 2020 Minutes. Commissioner Vaux Bell seconded the motion. All were in favor the motion passed. Town of Bluffton  Historic Preservation Commission Page 2 of 6 January 6, 2021 VII. ELECTION OF OFFICERS Two officer positions, Vice-Chair, and Historic Preservation Review Committee (HPRC) at large member was vacant. Chairman Trimbur nominated Commissioner Gallagher-Adams for vice-chair who accepted the nomination. Solomon motioned to approve; McNeil seconded the motion. All were in favor and the motion passed. Chairman Trimbur requested nominations for the HPRC at large member. Solomon asked if it was necessary to attend all Monday HPRC meetings. Peterson said that attendance was encouraged, however, as it is not a voting board and no action may be taken, is not necessary, comments are requested prior to the meeting date via email to the project manager. Vice-Chair Gallagher-Adams nominated Commissioner Solomon, who accepted the nomination. Commissioner McNeil seconded the motion. All were in favor and the motion passed. VIII. PUBLIC COMMENTS FOR ITEMS NOT ON THE AGENDA There were no public comments. IX. OLD BUSINESS There was no old business. X. NEW BUSINESS A. Certificate of Appropriateness: A request by Pearce Scott Architects, on behalf of the owners Gerard and Beth Romski, for approval of a Certificate of Appropriateness to allow the addition of an 85 SF golf cart bay and 600 SF second story addition to the existing one-story 514 SF Carriage House located at 5806 Yaupon Road, Lot 20A in the Stock Farm Development, in the Old Town Bluffton Historic District and zoned Neighborhood General- HD. (COFA-10-20-014698) (Staff – Katie Peterson) Peterson presented the information to the Commission, which is incorporated into these minutes. Chairman Trimbur asked Amanda Jackson Denmark, the Applicant, about changes necessary to foundation to support the proposed second story. She stated that any required modifications would be done on the inside and it is in the engineering process now. Vice-Chair Gallagher-Adams asked about the “bump-out.” Denmark explained that there was a desire to not make the main mass larger and taller while still gaining the square footage. Town of Bluffton  Historic Preservation Commission Page 3 of 6 January 6, 2021 Vice-Chair Gallagher-Adams made a motion to approve the application as submitted. Commissioner Solomon seconded the Motion. All were in favor and the motion passed. B. Certificate of Appropriateness: A request by Pearce Scott Architects, on behalf of the owner Kate Eagen, for approval of a Certificate of Appropriateness to allow the construction of a 1.5-story single-family residential structure of approximately 2,117 SF and a 2-story Carriage House of approximately 1,172 SF located at 5718 Guilford Place, Lot 45 in the Stock Farm Development in the Old Town Bluffton Historic District, and zoned Neighborhood General-HD. (COFA-10-20-014673) (Staff – Katie Peterson) Peterson presented the information to the Commission, which is incorporated into these minutes. While Peterson was presenting the landscape plan, Commissioner Solomon asked if the dashed line on the plans was for propane. Denmark responded that she did not know what that was. Chairman Trimbur added that the neighborhood has natural gas so it would not be propane. Commissioner Gallagher-Adams made a motion to approve the application with the following conditions: 1. Per Section 5.3.3.A.1 of the UDO, a Town of Bluffton tree removal permit is required for the removal of any trees over 14” in DBH. 2. Provide clarification on the 6” magnolia shown to stay on the site plan but removed on the landscape plan. 3. The HPC determined the columns may be approved as submitted due to the turn in the porch at the northwest corner and columns at the utility room may stay due to the constraint placed on the porch width clearance necessary for the washer and drier and the building code distance requirement for the locations of the door in proximity to the stairs. 4. Per Section 5.15.6.I. of the UDO, the exterior door style must be specified by owner prior to approval and Note 4 on the door schedule updated. 5. Per Section 3.2.2.E. of the UDO, a Grading Plan for the site is required for review as not enough information was provided at time of submittal. Commissioner Solomon seconded the motion. All were in favor and the motion passed. C. Certificate of Appropriateness - HD: A request by Webb Construction, on behalf of the owner Ernie Suozzi, for approval of a Certificate of Appropriateness to allow the construction of a 1.5-story-single-family Town of Bluffton  Historic Preservation Commission Page 4 of 6 January 6, 2021 residential structure of approximately 1,954 SF and a 1-story Carriage House of approximately 352 SF located at 20 Meriwether Court, Lot 3 in the Landen Oaks Development in the Old Town Bluffton Historic District, and zoned Neighborhood General-HD. (COFA-10-20-014694) (Staff- Katie Peterson) Peterson presented the information to the Commission, which is incorporated into these minutes. Chairman Trimbur asked if this structure could be a 2-story building. Peterson responded that as an Additional Building Type, it would not be permitted to be a two-story structure, it would be a Village House Building Type, which has increased setbacks. Peterson explained that while it may still classify as a 1.5-story structure, not enough information was provided by the Applicant to calculate the area which would have a possible head room of at least 5 feet. If the Applicant wishes to main the setbacks as shown on the Site Plan, the second story must not exceed 70% of the story beneath it. Westmark, as the representative of the Applicant, stated that the conceptual application submitted was a Village House, but has since revised the application to be an Additional Building Type to be able to meet the setback requirements. Peterson noted that the conceptual application did not meet the setbacks for either building type. Commissioner Solomon made a motion to approve the application with the following conditions: 1. Per Section 5.15.6.H. of the UDO, an additional column must be added to the to be spaced no farther apart than they are tall on the second- story porch, at the back of the house on the left elevation. 2. Per Section 5.15.5.C. The second-floor square footage must be updated, to be no more than 1.5 stories as defined by the UDO, and additional information must be provided regarding the possible floor area with head room of 5 feet or more. 3. The HPC determined that per Section 5.15.6.A the round window was appropriate for the gable, in conjunction with the rest of the detailing in the eaves, as a substitution for the window shapes listed in Section 5.15.6.I. of the UDO. Vice-Chair Gallagher-Adams seconded the motion. All were in favor and the motion passed. XI. DISCUSSION Town of Bluffton  Historic Preservation Commission Page 5 of 6 January 6, 2021 1. Discussion Regarding Building Size in Old Town Bluffton Historic District. Moore presented information to the Commission, which is incorporated into these minutes. Moore spoke about proposed amendments to the Main Street and Additional Building Types within the Neighborhood Center-HD zoning district (NCE-HD). The amendments are a response to Town Council’s concern that certain building types in the NCE-HD district may be too large and are incompatible with the character of Old Town. For the Main Street Building Type, the amendments included establishing differing building size ranges, square footages and heights (in stories) for the NCE-HD district and the Neighborhood Core-HD zoning district (NC-HD). Moore stated this was proposed as the character of the NCE-HD district was different than the NC-HD District, which includes developments like Promenade. Moore also discussed proposed amendments to the Front Build-to Zone and Side Setback for the Main Street and Additional Building Types. The Front Build- to Zone for both building types is proposed to a minimum of 10 feet and a maximum of 25 feet. This would allow larger buildings to be set back from the public right-of-way and be less overwhelming to the adjacent streetscape. The area in front of the building may serve as seating or outdoor dining areas. Additionally, Moore said the amendment proposed the Side Setback for the Additional Building Type be increased from a minimum of five feet to a minimum of eight feet, consistent with the Main Street Building Type. Amendments to the building footprint and size for Additional Building Types in all -HD zoning districts were also proposed to prevent the maximum size from exceeding the greatest maximum building size and footprint allowed by any of the other permitted building types in the same zoning district. Commissioner Gallagher-Adams stated that the building size range was decreased too substantially given the proposed footprint, and said that changing the permitted number of stories won’t make much of a difference as the limits on stories are broad. The proposed setback for the front build-to zone seems too substantial and suburban for a Main Street setting, like Calhoun Street, and the maximum depth of the Front Build-to Zone should be no more than 10 feet. Commissioner Solomon expressed concern with the current Front Build-to Zone with regards to the proximity of buildings to the sidewalks on Calhoun Street, which are no more than five feet. The amount of space does not provide enough room for pedestrians. An increased setback would allow the area to be used for other activities. Mt. Pleasant as an “activation” requirement for this space, as do other communities. He also mentioned that staff should look at buildings Town of Bluffton  Historic Preservation Commission Page 6 of 6 January 6, 2021 “that work” and determine their square footages. It was also suggested that height could be measured to the ridgeline. Chairman Trimbur asked about flat walls. Peterson replied that the UDO has requirements to prevent unarticulated blank facades. Vice-Chair Gallagher-Adams suggested the building at Calhoun Street and Bridge Street is an ideal height, with a reduction of two feet, to use as the maximum height. Commissioner Vaux-Bell felt that the newest buildings should not be used as precedent. There was agreement among the Commission that additional work is necessary with regards to building size. No action was taken as this item was for information only. XII. ADJOURNMENT Commissioner McNeil made a motion to adjourn the January 6, 2021 Historic Preservation Commission meeting. Vice Chair, Gallagher-Adams, seconded the motion, and all were in favor. The meeting was adjourned at 8:13 p.m. 114 Pritchard Street – Certificate of Appropriateness Historic Preservation Commission HISTORIC PRESERVATION COMMISSION STAFF REPORT Department of Growth Management MEETING DATE: February 6, 2021 PROJECT: 114 Pritchard Street–Addition to Single-Family Residential APPLICANT: Ansley H. Manuel, Architect PROJECT MANAGER: Katie Peterson, AICP, Senior Planner APPLICATION REQUEST: The Applicant, Ansley H. Manuel, on behalf of the owner, Patricia Ellen Malphrus, requests that the Historic Preservation Commission approve the following application: 1. COFA-12-20-014811. A Certificate of Appropriateness for the addition of approximately 2,971 SF to the existing single-family structure of approximately 1,095 SF located at 114 Pritchard Street in the Old Town Bluffton Historic District and zoned Neighborhood Conservation-HD. INTRODUCTION: The Applicant is proposing the construction of a 2,971 SF addition to the existing primary structure located at 114 Pritchard Street in the Old Town Bluffton Historic District. According to Beaufort County records, the single-family residence was originally constructed in approximately 1970. It has not been identified as a Contributing Structure within the Old Town Bluffton Historic District. While the existing structure likely classifies as a Cottage Building Type, the structure, with the proposed addition will not meet one of the permitted Building Types for the Neighborhood Conservation-HD zoning district, and therefore shall be reviewed as an Additional Building Type in accordance with Section 5.15.5.C. of the Unified Development Ordinance (UDO). The existing block structure is housed under a side-facing gable roof with two gabled projections to the front and a full-length rear porch under a shed roof. While most of the structure is painted concrete block, a small section on the south elevation and the gabled ends have wood siding. (See Attachment 6) The addition, which will be connected to the existing structure to the south by a small gabled hyphen, is a one and a half-story structure. The central mass is under a forward-facing gable roof surrounded on three sides by a one-story hip shed roof which is over the three sides not facing Heyward Cove. The rear (west) elevation, which faces towards Heyward Cove has an open balcony over the rear screened in porch. February 6, 2021 Page 2 114 Pritchard Street – Certificate of Appropriateness Historic Preservation Commission The materials proposed include vertical board and batten siding on the first floor with cedar shake on the second story. It features 5V crimp metal roofing to match the existing roof of the existing structure. This project was presented to the Historic Preservation Review Committee for conceptual review at the January 4, 2021 meeting and comments were provided to the Applicant (See Attachment 5). HISTORIC PRESERVATION COMMISSION ACTIONS: As granted by the powers and duties set forth in Section 2.2.6.E.2, the Historic Preservation Commission has the authority to take the following actions with respect to this application: 1. Approve the application as submitted by the Applicant; 2. Approve the application with conditions; or 3. Deny the application as submitted by the applicant. It is important to note that the intent of Section 5.15 Old Town Bluffton Historic District of the Unified Development Ordinance (UDO), is that the Section be user friendly and informative to the residents and the members of HPC and is not intended to discourage creativity or force the replication of historic models. Rather, it is to set forth a framework in which the diversity that has always characterized Bluffton can continue to grow. The Section also defines guidelines for design and materials similar to that used on structures within the Old Town, and it is the charge of the HPC to assess the interpretation of these guidelines as they pertain to applications using the established review criteria. REVIEW CRITERIA & ANALYSIS: Town Staff and the Historic Preservation Commission are required to consider the criteria set forth in Section 3.18.3 of the UDO in assessing an application for a Certificate of Appropriateness – Historic District (HD). The applicable criteria are provided below followed by a Staff Finding(s) based upon review of the application submittals to date. 1. Section 3.18.3.B. Consistency with the principles set forth in the Old Town Master Plan. a. Finding. The application is consistent with the principles set forth in the Old Town Master Plan. The Old Town Master Plan states that, “The built environment, in particular the historic structures scattered throughout Old Town, should be protected and enhanced. While it is of great importance to save and restore historic structures, it is just as important to add to the built environment in a way that makes Old Town more complete.” The Applicant proposes an addition to an existing single-family residential structure within the Old Town Bluffton Historic District, a locally and nationally designated historic district. The building has been designed to be sympathetic to the architectural character of the neighboring historic structures, so its addition to the architectural diorama will both protect the integrity of the existing historic structures and enhance the neighborhood by adding architectural variety. February 6, 2021 Page 3 114 Pritchard Street – Certificate of Appropriateness Historic Preservation Commission b. Finding. The Old Town Master Plan initiatives also include the adoption of a form-based code that included architectural standards for structures located within the Old Town Bluffton Historic District. These standards are included in Article 5 of the Unified Development Ordinance. The addition proposed as part of this request will be in conformance with those standards if the conditions noted in item 2 of this Section are met. c. Finding. The Old Town Master Plan initiatives also promote preservation and protection of the legacy of the Old Town Bluffton Historic District through additions to the built environment which make Old Town more complete. The proposed addition will continue to provide completeness to the neighborhood and overall district. 2. Section 3.18.3.C. The application must be in conformance with applicable provisions provided in Article 5, Design Standards. a. Finding. Town Staff finds that the design of the structure falls within the category of Additional Building Type within the Neighborhood Conservation Historic District per Section 5.15.5.D. As the Commission with approval authority in accordance with article 2 of the UDO, the HPC has final approval authority on the appropriateness of an Additional Building Type within this zoning district. Town Staff requests the Historic Preservation Commission review and make a final recommendation regarding the appropriateness of the Additional Building Type. b. Finding. Town Staff finds that if the conditions noted below are met, the proposed addition will be in conformance with applicable provisions provided in Article 5: 1) Section 5.15.5.F.4. Building Composition (Proportion, Alignment, Rhythm, and Spacing). Overall building proportions and Individual building features shall have a proportional relationship with one another. For example, features such as porches, chimneys, cornices, windows, and doors must be proportional to other features of the building as well as the overall building form. The Applicant’s Narrative notes the chimney on the new addition has been changed to Old Savannah or Charleston brick with similar detailing and cap design to echo the detail on the existing structure. The roof material is proposed to be the same 5V crimp metal. They have also proposed a painted CMU foundation to match the existing structure (see comment 6). In addition to the elements from the existing structure brought to the new addition, they have proposed to replace the existing wood siding (found on what will become the courtyard near the connection of the two structures) on the existing structure with board and batten on the majority with cedar shake on the gabled ends. Town Staff requests the HPC determine if these additions establish a relationship between the two structures, so they appear to have similar character to meet the intent of this section. February 6, 2021 Page 4 114 Pritchard Street – Certificate of Appropriateness Historic Preservation Commission 2) Section 5.15.6.H.2.d. Columns, Arches, Piers, Railings, Balustrades. Railings and balusters are permitted to be Wood (termite resistant), painted or natural Wrought or Cast Iron. Detail B on page A9 notes the railing section to have a teak handrail with stainless steel cable. The Applicant is requesting the HPC allow the use of this material as a substitute material for those listed as options under the Architectural Standards as permitted by Section 5.15.6.A. of the UDO. Section 5.15.6.A. notes that the UDO Administrator, in this case the HPC as the approval authority for Certificate of Appropriateness-HD Applications, shall have authority to approve substitute materials for those listed as options under the Architectural Standards as an additional reference for architectural standards, refer to Traditional Construction Patterns, by Stephen Mouzon (McGraw Hill, 2004). 3) Section 5.15.6.I.3.a Windows and Doors. Windows are permitted to be square, rectangle, transom, or sidelight. The plans propose a circular window on the east elevation and two right trapezoids on the west elevation. The Applicant is requesting the HPC allow the use of this material as a substitute material for those listed as options under the Architectural Standards as permitted by Section 5.15.6.A. of the UDO. 4) Section 5.15.5.F.1.c. General Standards. The first-floor finish height must be 3 feet above the average adjacent sidewalk grade. While there is no sidewalk, the measurement shall be taken from the where the sidewalk would exist along Pritchard Street. As this is an addition to an existing structure, the Applicant is requesting a deviation from the requirement of the 3-foot finished floor height. Staff recommends the deviation be allowed, however, requires that the finished floor height, at least from adjacent grade, for the existing structure be labeled on the elevations to ensure the addition will match at time of construction. 5) Section 5.15.6.E.5.c. Porches. Porches are required to have a minimum height of 30 inches minimum from the adjacent grade to the top of stairs. The narrative estimates the top of stair is at approximately 2 feet 3 inches, 9 inches less than requirement. The porch height must be raised. The height of the porch must be increased to meet this requirement. 6) Section 5.15.6.G.1.a. Building Walls. Exposed foundation walls (below the first-floor elevation) shall be Brick done in bond patterns; Painted brick; Tabby stucco (mixed shell size only); or Stucco over block or concrete (sand-finished or steel trowel only). The application proposes the foundation be concrete block sealed and painted to match the existing cottage in lieu of tabby or stucco. While this is not a permitted configuration, the Applicant is February 6, 2021 Page 5 114 Pritchard Street – Certificate of Appropriateness Historic Preservation Commission requesting the HPC allow the use of this material as a substitute material for those listed as options under the Architectural Standards as permitted by Section 5.15.6.A. of the UDO. 7) Section 5.15.7.D.1. Parking. In no case shall parking be located in front of a building. The plan proposes a new gravel drive, with a parking area towards the southwest side of the property line. The parking area is not behind the front plane of the structure and must be relocated to the side or rear of the structure. 3. Section 3.18.3.D. The nature and character of the surrounding area and consistency of the structure with the harmony of the surrounding neighborhood. Finding. Town Staff finds that nature and character of the addition to the existing structure is consistent and harmonious with that of the surrounding neighborhood. The mass and scale of the addition is appropriate for its location and the architectural detailing is sensitive to the neighboring properties. 4. Section 3.18.3.F. The historic, architectural, and aesthetic features of the structure including the extent to which its alteration or removal would be detrimental to the public interest. Finding. The Applicant seeks approval for the addition to a single-family residential structure built in approximately 1970 in the Old Town Bluffton Historic District. The proposed plans are sympathetic in design to the neighboring historic and non-historic resources; therefore, the addition, as proposed, will have no adverse effect on the public interest. 5. Section 3.18.3.H. The application must comply with applicable requirements in the Applications Manual. Finding. The Certificate of Appropriateness Application has been reviewed by Town Staff and has been determined to be complete, however, the following items must be addressed prior to approval of this application. 1) Per Section 3.22.2.A., a Town of Bluffton Tree Removal Permit is required for any tree 14” (DBH) or greater located on a single- family lot and proposed for removal. 2) Per Section 5.3.3.G., the landscape plan must be updated to show the site meets the 75% lot coverage with tree canopy measured as the mature canopy, not included rooftops. STAFF RECOMMENDATION: It is the charge of the HPC to assess and interpret the standards and guidelines set forth in the UDO as they pertain to applications using the review criteria established in the UDO and to take appropriate action as granted February 6, 2021 Page 6 114 Pritchard Street – Certificate of Appropriateness Historic Preservation Commission by the powers and duties set forth in Section 2.2.6.E.2. Town Staff finds that requirements of Section 3.18.3 of the Unified Development Ordinance have been met and recommends that the Historic Preservation Commission approve the application with the following conditions: 1. Per Section 5.15.5.F.4., the HPC must determine if the overall building proportions and individual building features have a proportional relationship with one another. 2. Per Section 5.15.6.A., the Applicant is requesting a determination on the appropriateness of the use of Stainless-Steel Cables in the railings as a substitute material for those listed in Section 5.15.6.H.2.d. of the UDO. 3. Per Section 5.15.6.A., the Applicant is requesting a determination on the appropriateness of the use of a circular window on the east elevation as a substitute material for those listed in 5.15.6.I.3.a of the UDO. 4. Per Section 5.15.6.A., the Applicant is requesting a determination on the appropriateness of the use of two right trapezoid windows on the west elevation as a substitute material for those listed in 5.15.6.I.3.a of the UDO. 5. The Applicant requests a determination on the appropriateness of the first finished floor height below 3 feet to match the existing structure. Staff requests a height be added to the elevations, should this be permitted, to ensure it matches at time of construction. 6. Per Section 5.15.6.E.5.c., the porch height must be increased to have a minimum height of 30 inches minimum from the adjacent grade to the top of stairs. 7. Per Section 5.15.6.A., the Applicant is requesting a determination on the appropriateness of the use of a concrete block sealed and painted to match the existing cottage foundation as a substitute foundation material for those listed in Section 5.15.6.G.1.a. of the UDO. 8. Per Section 5.15.7.D.1. the parking area must be relocated to the side (behind the front plane of the structure) or rear of the structure. 9. Per Section 3.22.2.A., a Town of Bluffton Tree Removal Permit must be obtained for any tree 14” (DBH) or greater located on a single-family lot and proposed for removal. 10.Per Section 5.3.3.G., the landscape plan must be updated to show the site meets the 75% lot coverage with tree canopy measured as the mature canopy, not included rooftops. ATTACHMENTS: 1. Location Map 2. Zoning Map 3. Applicant Narrative 4. Application and Plans 5. HPRC Comments H eyw a rd C o ve Location Map - 114 Pritchard Street 1 / 2 8 / 2 0 2 1 0 0 . 0 3 0 . 0 5 0 . 0 8 0 . 1 0 . 1 30 . 0 1 m i F I n f o L a y e r P a r c e l P r o p e r t y L in e s ATTACHMENT 1 H eyw a rd C o ve Zoning Map - 114 Pritchard Street 1 / 2 8 / 2 0 2 1 0 0 . 0 3 0 . 0 5 0 . 0 8 0 . 1 0 . 1 30 . 0 1 m i F I n f o L a y e r P a r c e l P r o p e r t y L in e s ATTACHMENT 2 ATTACHMENT 3 ATTACHMENT 3 ATTACHMENT 3 ATTACHMENT 3 ATTACHMENT 3 ATTACHMENT 3 Plan Review Comments and Response from Owner /Architect - Jan. 7, 2021 Property : Ellen Malphrus - 114 Pritchard St, Bluffton Staff Review & Owner Architect Comments - 12.4.2021 1. Windows are permitted to be square, rectangle, transom or sidelite. The plans propose a circular window on the east elevation and two right trapezoids on the west elevation. Windows must be revised to meet this requirement. (UDO 5.15.6.I.3.a.) 2.The UDO requires that porch posts shall be spaced no farther apart than they are tall. Columns are proposed as further apart on center than they are tall on the west elevation. The column placement must be revised to meet this requirement. (UDO5.15.6.H.1.a. and Traditional Construction Patterns Section 52) Okay - We have added an additional column as recommended by the Review Team 3.The first floor finish height must be 3 feet above the average adjacent sidewalk grade. While there is no sidewalk, the measurement shall be taken from the where the sidewalk would exist along Pritchard Street. Provide elevation of adjacent sidewalk grade to confirm that the finished floor is 36" above grade. (UDO Section 5.15.5.F.1.c.) 4.Porches are required to have a minimum height of 30 inches minimum from the adjacent grade to the top of stairs. The proposed height to top of stairs is 2' 3". The height of the porch must be increased to meet this requirement. (UDO Section 5.15.6.E.5.c.) 5.Provide additional information to clarify the finish of the stucco proposed on the foundation and chimney (tabby, sand-finished, and steel trowel are permitted). (UDO 5.15.6.G.1.a.) Response to Proposed Circular Window: We would ask that the the review board grant a variance from the the UDO for one round window, as we have envisioned this one traditional round window as a tribute to the historic architecture of the south. Below are 3 examples of a single round window located in the peak of the gable of historic structures in Beaufort & Charleston. Response to (2) Cove Side Gable End Trapezoid Windows: We would ask that the the review board grant an exception from the the UDO regarding the 2 trapezoid windows on the cove side or west elevationof the house as they are critical to our goal of bringing the outside in. We are building our new home as a timber structure using Eastern White Pine & North Carolina Hemlock. The benefit of building a timber structure is that aside from the inherent beauty of seeing the bones of your home built of the finest natural and local materials, we can maximize the useful area of the interior, and the gable ends are not filled with framing materials and solid wall construction, making these windows possible. There are other homes in Martin's Place just on the other side of Pritchard St. with promenent Trapezoid windows, our's could not be seen by anyone, ever, because of the way the house is situated on the cove side so they would be setting no precedent. Response to Building Height in relation to a Non-Existent Sidewalk: Pritchard Street is one of the last dirt and oyster shell roads left in Bluffton. We have been assured by our city planners and leaders, that the street will remain unpaved and without sidewalks as a matter of preservation and honoring bygone days. The relationship between our proposed house and existing cottage elevation, and a non-existent sidewalk is difficult to understand. The existing Cottage finish floor is around 23' above sea level and the road is at 20' above sea level. We would ask that the Review Board allow the new addition's finished floor to match that of the existing floor. As we understand from our meetings with the preliminary review team, one of the design criteria goals of the UDO is to honor the original structure and have the new addition and the existing be as cohesive as possible. To raise the elevation of the new structure above the existing cottage, would dwarf the cottage, aside from being a tremendous dissapointment to the flow of the house. Also, we are building this additionwith full consideration of its livabilityas we grow older. A change in elevation between our bedroom and the living area would defeat this goal. Response: The estimated top of stair at the east elevation was drawn in at 2'-3" above grade, just 9" shy of the 30" requirement. The property slopes down steadily towards the south (Water Street) and it necessary the porch stair could be lenghtened to acheive the 30" requirement. Response: In an effort to comply with the continuity goals of the UDO regarding tiying in old to new, we have changed the chimney to an old savannah brick to match the existing cottage chimney and would suggest that the existing foundation wall be costructed of concrete block sealed and painted to match the existing cottage construction in lieu of tabby or stucco as there is none on the existing. ATTACHMENT 3 6. Additional information must be provided on the walls behind the screened area on the west elevation as there is not enough information to complete review. (Applications Manual) 7.Building heights and widths shall be visually similar to those in the neighboring vicinity. As the addition to this structure is more than double the size of the existing structure, additional information showing the scale of the proposed in relation to the neighboring properties must be provided. (UDO 5.15.5.F.1.a.) 8.At time of final submittal, a landscape plan showing foundation buffers, canopy coverage, and street trees must be provided for review. (Applications Manual) Response: Okay Drawing's have been further detailed with a Landscape Plan 9.A Town of Bluffton Tree Removal Permit is required for any tree 14” (DBH) or greater located on a single family lot and proposed for removal (UDO Section 3.22.2.A.). Response: Okay Our goal is to preserve our ample trees and gardens. We will request a permit for any tree that must be removed. 10.The site plan shows a carport proposed to be inclosed. No information on the carport was provided. Additional information must be provided for review. Response: Carport will be left as is for the time being. 11.Railings are permitted to be wood (termite resistant), painted or natural wrought or cast iron. The plans note the use ofcable railings on the second story balcony on the west elevation. Railings must be revised to meet this standard. (UDO 5.15.6.H.2.d.) Response: We would ask the review board to please consider allowing the use of Stainless Steel Cable Railing on the second story balcony on the west elevation facing Heyward Cove. The balcony is in the plan as an open deck to be for observation of wildlife and to enjoy the cove. A cable railing offers the least obstruction to the view and has been used on other recent projects in Bluffton. The most recent example is on the Cunningham Residence, located just one cove down from Heyward Cove. Again, the cove/west side of the house cannot be seen from any street. 12.In no case shall parking be located in front of a building. The plan proposed a new gravel drive, all of which is located in front of the primary structure. The driveway must be reconfigured to allow parking to be located on the side or the rear of the structure.(UDO 5.15.7.D.1.) Response: We will Comply - We have revisited the driveway and parking at the request of the Preliminary Review Team and have studied the existing landscape. We would propose that 2 parking spaces be carved into the heavily landscaped buffer between our property and Water Street on the south side of the new addition, being cautious not to disrupt the natural grade, as this area is a critical natural drainage into the river. The existing trees and mature landscaping are essential to providing a natural buffer to Water Street and the OCRM Buffer. Since the "back" of the house actually fronts the cove, this is the only reasonable solution. The driveway and parking will be pervious to match existing shell mix. Manning House - Directly Across the Street 125 Pritchard Street - 2 Story with Garage 32+' above grade - Very Large Home Home with frontage in Martin's Place and Back Side on Water Street ATTACHMENT 3 Proposed Pervious Driveway and Parking Plan 13.Provide additional information on the existing chimney to ensure the proposed has a visual relationship to the existing. Additionally, provide additional information on the proposed chimney cap. In keeping with masonry building technology, metal spark arrestors, exposed metal flues, or pre-fabricated chimney caps are not permitted. (5.15.6.E.8.d.) 14. At time of final submittal provide architectural details of the railing and baluster, a typical window detail, corner board/pilaster trim detail and sections through the eave and wall depicting the material configuration and dimensions. (Applications Manual) 1.Overall building proportions and Individual building features shall have a proportional relationship with one another. For example, features such as porches, chimneys, cornices, windows and doors must be proportional to other features of the building as well as the overall building form. Based on the plans submitted, the existing structure does not have many elements which tie it to the proposed addition -possible chimney detailing and a metal roof. Provide detailing showing the relationship between the addition and the existing structure. Additionally, additions, connective wings, and outbuildings shall be secondary to the primary form. Provide additional information showing how the exiting structure will be prominent. (UDO 5.15.5.F.4. and UDO 5.15.5.F.4.a.) Response: The existing chimney is constructed of brick and has a metal chimney cap. We propose that the new Chimney be constructed of brick, similar to Old Savannah or Charleston traditional material, with a similar metal cap to ensure continuity with the old & new. Response: Included in this submittal Response to Overall Comments: As discussed in our Preliminary Review Meeting, the existing concrete block cottage does not have bold architectural features to incorporate into the new addition, but there are subtle elements that are culturally of value, and should be carried into the new structure to honor the existing building and create a cohesive blend of new and old. ATTACHMENT 3 Response to Overal Comments - continued Elements of construction and design to bring into the new building: • Use of brick for the new chimney - Old Savannah or Charleston brick to echo in tone and detail. Masonry details, and cap design would be similar. • We intend to use the same 5v crimp Galvelum roofing material as the existing cottage. • The new addition has board and batten siding on the first floor and cedar shakes above. At the recommendation of the Preliminary Review Team we would suggest replacing the existing wood siding on the cottage with board and batten on the main level and cedar shake on the existing gable ends. • To further bring the cottage elements into the new addition, we would propose that the foundation walls be painted concrete block to match the cottage. This will create a harmonious flow across the entire house. ATTACHMENT 3 C2 SITE PLAN 1/8/21 DATE : MANUEL STUDIO, LLC Ansley Hester Manuel, Architect 104 Pritchard Street, Bluffton, South Carolina 29910 843.338.8932 cell manuel.studio@aol.com SHEET MANUEL STUDIO, LLC BLUFFTON, SC 100072 ANSLEY HESTER MANUEL BLUFFTON, SC 6887 ANILORACHTUOSFOETATS REGISTERED ARCHITECT ANILORACHTUOSFOETATS REGISTERED ARCHITECT ADDITIONS & RENOVATIONS TO THE MALPHRUS/FISHKIND RESIDENCE 114 PRITCHARD STREET BLUFFTON, S.C. S SITE PLAN SCALE: 1"=70'-0" A C2 11" LAUREL OAK 22" LAUREL OAK (DISEASED) (TO BE REMOVED) PALMETTO LIVE OAK 28" MAGNOLIA PALMETTO 26" MAGNOLIA 26" PINE PALMETTO PALMETTO PALMETTO PALMETTO PALMETTO PINE CEDAR PINE PINE PINE PINE LAUREL OAK LAUREL OAK LAUREL OAK LAUREL OAK LAUREL OAK PINE PINE PINE PINE 8" PINE 26" LAUREL OAK DOGWOOD 22" PINE CEDAR GUM 14" PALMETTO 23" PINE CEDAR CEDAR MAGNOLIA 26" LAUREL OAK PINE 17" PINE WATER OAK EXISTING RESIDENCE AREA OFEXISTINGSEPTICSYSTEMTANK EXIST. CARPORT 10' SETBACK 58' SETBACK (VARIANCE) 58' SETBACK (VARIANCE) PROPOSEDADDITION NEW CONC. WALK NEW GRAVEL DRIVE 10' SETBACK 35' SETBACK NEW GRAVEL PARKING DOGWOOD PINE LAUREL OAK LAUREL OAK PALMETTO WATER OAK PINE TP PALM PINE LAUREL OAK CEDAR CREPE MYRTLE PINE PINE PINE PINE PALMETTO PALMETTO PALMETTO DW FH CEDAR LAUREL OAK LAUREL OAK LAUREL OAK LAUREL OAK MAGNOLIA MAGNOLIA PINE DOGWOOD MAGNOLIA MAGNOLIA PALMETTOGUM LAUREL OAK LAUREL OAK PINE PINE CEDAR PALMETTO TO MOVE LIVE OAKLIVE OAK PALMETTO LIVE OAK SHADE GARDEN ORNAMENTAL PLANTS AZELEAS RAVINE CEDAR WATER OAK MAGNOLIA MAGNOLIA HICKORY LIVE OAK PALMETTO PINE CEDAR LAUREL OAK LAUREL OAK PINE PINE PINEPINE LIVE OAK LAUREL OAK LAUREL OAK LAUREL OAK LAUREL OAK LAUREL OAK HEAVY UNDERBRUSH ORNAMENTAL PLANTS AZELEA AZELEA AZELEA AZELEA CAMELIA SAGO PALM OAK LEAF HYDRANGEA HYDRANGEA HYDRANGEA DWARF GARDENIAS BENCH MARKER 22.62 -8" GRADE ALONG DIRT ROAD (21.62) ATTACHMENT 4 6" A1 PROPOSED FIRST FLOOR PLAN 1/8/21 DATE : MANUEL STUDIO, LLC Ansley Hester Manuel, Architect 104 Pritchard Street, Bluffton, South Carolina 29910 843.338.8932 cell manuel.studio@aol.com SHEET MANUEL STUDIO, LLC BLUFFTON, SC 100072 ANSLEY HESTER MANUEL BLUFFTON, SC 6887 ANILORACHTUOSFOETATS REGISTERED ARCHITECT ANILORACHTUOSFOETATS REGISTERED ARCHITECT ADDITIONS & RENOVATIONS TO THE MALPHRUS/FISHKIND RESIDENCE 114 PRITCHARD STREET BLUFFTON, S.C. S Great Room 38'-1"X19'-8" Breakfast Room 14'-6"X9'-8" Kitchen 13'-10"X12'-4" Screened Porch 33'-5"-X13'-4" Bedroom2 13'-3"X13'-10" Screened Porch 12'-11"X13'-2" Front Porch 33'-6"X7'-2" Existing Carport Andy & Ellen's Bedroom 19'-6"X13'-4" Existing ConstructionProposed Andy's Office 12'-0"X12'-0" Ellen's Atelier 12'-0"X12'-0" Screened Writer's Porch 23'-8"X7'-7" Ellen's Boudoir 16'-0"X10'-0" Library 9'-4"X5'-6" Reading Nook 13'-3"X8'-0" Bath 2 Bath 1 Mudroom 10'-11"X7'-6" Laundry 8'-11"X8'-3" W.I.C. 8'-11"X6'-4" Bath 3 Foyer 6'-0"X24'-4" LAVW/C TUB/SH LINEN R&SH Furniture Nook BOOKS BOOKS CABS SINK W D SINKDW FIREPLACE DN DN DN ISLAND CABS CONVECT. OVEN REF. PROPOSED FIRST FLOOR PLAN SCALE: 1/4"=1'-0" A A1 UP OPEN TO ABOVE 16R CABS CABS OVEN/ RANGE DN DN Secret Garden Utility Closet Pantry 10'-11"X7'-6" 66'-6" 48'-0" 34'-5" 13'-7" 9'-4" 49'-6" 36'-9" 1 DP35 3 3 5 DP45 4 DP45 4 DP45 6 DP35 2 DP35 2 DP45 3 6 DP35 2 DP35 A DP35 A DP35 A DP35 A DP35 A DP35 B DP35 B DP35 B DP35 B DP35 B DP35 B DP35 C DP35 C DP35 C DP35 C DP35 C DP35 C DP35 A DP35 57'-4" 7'-11 2" 6'-91 2" 6'-83 4" 6'-83 4" 7'-03 4" 13'-7" 9'-4" 49'-6" 106'-10" 7'-11 2" 10'-7" 3'-31 2" 6'-0" 3'-31 2" 4'-11 2" 6'-81 2" 6'-101 2" 4'-8" 4'-8" 7'-1" 6'-9" 6'-9" 6'-9" 6'-9" 6'-91 2" 7'-11 2" 7'-10" 44'-8" 14'-0" 7'-10" 6'-8" 22'-8" 10'-0" 5'-4" 7'-0" 7'-0" 3'-81 2" 6'-9" 6'-9" 10'-11 2" 7'-1" 11'-1" 2'-6" 7'-3" 6'-7" 2'-4" 23'-91 2" 11'-9" 6'-21 2" 1'-6" CL CL CL CL CL CLCLCLCL CL CL CL CL CL CL CLCLCLCLCL CLCLCLCL CLCLCL 49'-6" 7'-6" 1'-10" ATTACHMENT 4 A2 PROPOSED SECOND FLOOR PLAN 1/8/20 DATE : MANUEL STUDIO, LLC Ansley Hester Manuel, Architect 104 Pritchard Street, Bluffton, South Carolina 29910 843.338.8932 cell manuel.studio@aol.com SHEET MANUEL STUDIO, LLC BLUFFTON, SC 100072 ANSLEY HESTER MANUEL BLUFFTON, SC 6887 ANILORACHTUOSFOETATS REGISTERED ARCHITECT ANILORACHTUOSFOETATS REGISTERED ARCHITECT ADDITIONS & RENOVATIONS TO THE MALPHRUS/FISHKIND RESIDENCE 114 PRITCHARD STREET BLUFFTON, S.C. S PROPOSED SECOND FLOOR PLAN SCALE: 1/4"=1'-0" A A2 BOOKSBENCHBOOKSBOOKSBOOKS BENCH BOOKSBENCHBOOKSBOOKSBENCH OPEN TO BELOW Loft 12'-1"X19'-5" DN Storage 20'-2"X7'-11" Bath 4 LAV W/C SH 16R Balcony 13'-3"X19'-4" 10" TEAK HANDRAIL 20'-10" 44'-8" 14'-1" 58'-9" 7 DP45 7 DP45 D DP35 D DP35 E DP35 E DP35 E DP35 E DP35 E DP35 E DP35 E DP35 E DP35 A DP35 A DP35 A DP35 F DP45 ABOVE 6'-8" 12'-0" 10'-8" 10'-0" 5'-4" 14'-1" 10'-5" 10'-5" 2'-9" 4'-1" 1'-11" 3'-4" 1'-11" 4'-1" 2'-9" 21'-0" 44'-8" 6'-8" 12'-0" 10'-8" 10'-0" 5'-4" 14'-1" 14'-1" 58'-9" ATTACHMENT 4 A3 PROPOSED ROOF PLAN 1/8/21 DATE : MANUEL STUDIO, LLC Ansley Hester Manuel, Architect 104 Pritchard Street, Bluffton, South Carolina 29910 843.338.8932 cell manuel.studio@aol.com SHEET MANUEL STUDIO, LLC BLUFFTON, SC 100072 ANSLEY HESTER MANUEL BLUFFTON, SC 6887 ANILORACHTUOSFOETATS REGISTERED ARCHITECT ANILORACHTUOSFOETATS REGISTERED ARCHITECT ADDITIONS & RENOVATIONS TO THE MALPHRUS/FISHKIND RESIDENCE 114 PRITCHARD STREET BLUFFTON, S.C. S PROPOSED ROOF PLAN SCALE: 1/4"=1'-0" A A3 3:12 HIP/SHED 8:12 GABLE 3:12 HIP 8:12 GABLE 3:12 HIP 3:12 HIP 3:12 GABLE 3:12 GABLE 2.3:12 SHED 2.3:12 SHED 6:12 GABLE 6:12 GABLE 6:12 GABLE 6:12 GABLE 6:12 GABLE 6:12 GABLE 6:12 GABLE 3:12 GABLE 24" 14" 24" 24" 24" 24" 14" 24" 24"24" TIGHT TO RAKE 24" SLOPE Balcony ATTACHMENT 4 A4 PROPOSED ELEVATIONS 1/8/21 DATE : MANUEL STUDIO, LLC Ansley Hester Manuel, Architect 104 Pritchard Street, Bluffton, South Carolina 29910 843.338.8932 cell manuel.studio@aol.com SHEET MANUEL STUDIO, LLC BLUFFTON, SC 100072 ANSLEY HESTER MANUEL BLUFFTON, SC 6887 ANILORACHTUOSFOETATS REGISTERED ARCHITECT ANILORACHTUOSFOETATS REGISTERED ARCHITECT ADDITIONS & RENOVATIONS TO THE MALPHRUS/FISHKIND RESIDENCE 114 PRITCHARD STREET BLUFFTON, S.C. S A A4 PROPOSED EAST ELEVATION SCALE: 1/4"=1'-0" (FACES PRITCHARD STREET) B A4 PROPOSED NORTH ELEVATION CUT THROUGH CONNECTOR SCALE: 1/4"=1'-0" 3 12 8 12 3 12 6 12 EXIST. 5V CRIMP SEAM @ 16" O.C. EXIST. CMUNEW BOARD AND BATTEN TO MATCH ADDITION 2'-3" 8'-3" 3 12 GRADE SLAB TOP OF PLATE SHINGLES BOARD & BATTEN 5V CRIMP SEAM @ 16" O.C. MATCH EXISTING BRICK AND CHIMNEY CAP PAINTED CONCRETE BLOCK FOUNDATION NEW SHINGLES TO MATCH ADDITION PAINTED CONCRETE BLOCK FOUNDATION ATTACHMENT 4 A5 ELEVATIONS 1/8/21 DATE : MANUEL STUDIO, LLC Ansley Hester Manuel, Architect 104 Pritchard Street, Bluffton, South Carolina 29910 843.338.8932 cell manuel.studio@aol.com SHEET MANUEL STUDIO, LLC BLUFFTON, SC 100072 ANSLEY HESTER MANUEL BLUFFTON, SC 6887 ANILORACHTUOSFOETATS REGISTERED ARCHITECT ANILORACHTUOSFOETATS REGISTERED ARCHITECT ADDITIONS & RENOVATIONS TO THE MALPHRUS/FISHKIND RESIDENCE 114 PRITCHARD STREET BLUFFTON, S.C. S A A5 PROPOSED WEST ELEVATION SCALE: 1/4"=1'-0" (FACES HEYWARD COVE) 8 12 3 12 5V CRIMP SEAM @ 16" O.C. EXIST. CMU B A5 PROPOSED SOUTH ELEVATION SCALE: 1/4"=1'-0" (FACES WATER STREET) SHINGLES BOARD & BATTEN CABLE RAILING MATCH EXISTING BRICK AND CHIMNEY CAP PAINTED CONCRETE BLOCK FOUNDATION PAINTED CONCRETE BLOCK FOUNDATION ATTACHMENT 4 A6 ELEVATIONS 1/8/21 DATE : MANUEL STUDIO, LLC Ansley Hester Manuel, Architect 104 Pritchard Street, Bluffton, South Carolina 29910 843.338.8932 cell manuel.studio@aol.com SHEET MANUEL STUDIO, LLC BLUFFTON, SC 100072 ANSLEY HESTER MANUEL BLUFFTON, SC 6887 ANILORACHTUOSFOETATS REGISTERED ARCHITECT ANILORACHTUOSFOETATS REGISTERED ARCHITECT ADDITIONS & RENOVATIONS TO THE MALPHRUS/FISHKIND RESIDENCE 114 PRITCHARD STREET BLUFFTON, S.C. S A A6 NORTH ELEVATION SCALE: 1/4"=1'-0" (FACES COVE STREET) 2.3 12 B A6 SOUTH ELEVATION CUT THROUGH CONNECTOR SCALE: 1/4"=1'-0" (FACES WATER STREET) 6 12 6 12 NEW BOARD & BATTEN TO MATCH ADDITION EXIST. 5V CRIMP SEAM @ 16" O.C. EXIST. CMUEXIST. CMU EXIST. 5V CRIMP SEAM @ 16" O.C. 2.3 12 6 12 2'-0" 8'-0" TOP OF PLATE TOP OF SLAB GRADE 8'-3" 3 12 NEW SHINGLES TO MATCH ADDITION NEW SHINGLES TO MATCH ADDITION ATTACHMENT 4 A7 WALL SECTIONS 1/8/21 DATE : MANUEL STUDIO, LLC Ansley Hester Manuel, Architect 104 Pritchard Street, Bluffton, South Carolina 29910 843.338.8932 cell manuel.studio@aol.com SHEET MANUEL STUDIO, LLC BLUFFTON, SC 100072 ANSLEY HESTER MANUEL BLUFFTON, SC 6887 ANILORACHTUOSFOETATS REGISTERED ARCHITECT ANILORACHTUOSFOETATS REGISTERED ARCHITECT ADDITIONS & RENOVATIONS TO THE MALPHRUS/FISHKIND RESIDENCE 114 PRITCHARD STREET BLUFFTON, S.C. S 2X6'S @ 16" O.C. STUD WALL WITH CONTINUOUS TIE ROD FROM CMU EMBEDMENT TO TOP PLATE BOARD AND BATTEN (SEE DETAIL) OVER HOUSEWRAP OVER 1/2" CDX PLYWOOD (FULL 48" TOP AND BOARD) BLOCKING BEHIND PLYWOOD SEAM HURRICANE STRAPS OR CLIPS @ EA. RAFTER SIMPSON OPTIONS 1: (2) H2.5, 2: MTS20, OR 3: H10 5V CRIMP METAL ROOF OVER 30# FELT OVER 5/8" CDX PLYWOOD OVER 3 1/2" S.I.P.S. (INSULATED PANEL) WITH 2X4 FIR STUDS @ 12" O.C. FOR ATTACHMENTS METAL DRIP EDGE A A7 TYPICAL WALL SECTION SCALE: 1"=1'-0" 3X8'S @ 24" O.C. RAFTERS WITH TAPERED TAILS 1X6 FASCIA 24" OVERHANG 2 6 2 6 2 6 2 6 2 4 2 4 2 4 2 4 2 4 2 4 24" 12" 8'-3" TOP OF SLAB VARIES GRADE TOP OF PLATE 3 12 8 12 9'-0" 12" 6'-8" TOP OF SLAB BOT OF BEAM TOP OF BEAM TOP OF PLATE 16" 2 4 2 4 2 4 2 4 2 4 2 4 2 4 2 4 2 4 2 4 2 4 2 4 2 4 2 4 2 4 2 4 1X RANDOM WIDTH SOFFIT FINISH 2X8 BIRDBLOCK 2X6 CORNICE R-13 SPRAY FOAM INSULATION "L" BLOCK WITH (1) #5'S VERTICAL REBAR. GROUT SOLID. PAINTED FINISH TO MATCH EXISTING COTTAGE 8" CMU STEM WALL WITH (2)#5'S VERTICAL REBAR. GROUT SOLID. CONCRETE FOOTING WITH (3)#5'S REBAR WOOD FLOORS OVER 4" CONCRETE SLAB WITH 6X6 W1.4 X W1.4 WWF OVER 6 MIL VAPOR BARRIER, DOUBLE 3' FROM EDGE 2X4'S @ 16" O.C. STUD WALL WITH CONTINUOUS TIE ROD FROM CMU EMBEDMENT TO TOP PLATE WOOD WALL FINISH 1X RANDOM WIDTH CEILING FINISH HURRICANE STRAPS OR CLIPS @ EA. RAFTER SIMPSON OPTIONS 1: (2) H2.5, 2: MTS20, OR 3: H10 5V CRIMP METAL ROOF OVER 30# FELT OVER 5/8" CDX PLYWOOD OVER 3 1/2" S.I.P.S. (INSULATED PANEL) WITH 2X4 FIR STUDS @ 12" O.C. FOR ATTACHMENTS METAL DRIP EDGE HEAVY TIMBER RAFTER WITH TAPERED TAILS WITH HEAVY TIMBER PURLING 1X6 FASCIA 1X RANDOM WIDTH SOFFIT FINISH 2X6 CORNICE 24" OVERHANG ROOF FLASHING WOOD SHINGLES OVER HOUSEWRAP OVER 1/2" CDX PLYWOOD (FULL 48" TOP AND BOARD) BLOCKING BEHIND PLYWOOD SEAM 10" WOOD WALL FINISH HEAVY TIMBER FRAME STRUCTURE (SEE SHOP DRAWING BY LOPER) 2 4 2 4 2 4 2 4 2 4 2 4 2 4 2 4 PITCH SOIL ATTACHMENT 4 A8 WALL SECTIONS 1/8/21 DATE : MANUEL STUDIO, LLC Ansley Hester Manuel, Architect 104 Pritchard Street, Bluffton, South Carolina 29910 843.338.8932 cell manuel.studio@aol.com SHEET MANUEL STUDIO, LLC BLUFFTON, SC 100072 ANSLEY HESTER MANUEL BLUFFTON, SC 6887 ANILORACHTUOSFOETATS REGISTERED ARCHITECT ANILORACHTUOSFOETATS REGISTERED ARCHITECT ADDITIONS & RENOVATIONS TO THE MALPHRUS/FISHKIND RESIDENCE 114 PRITCHARD STREET BLUFFTON, S.C. S A A8 FRONT PORCH SECTION SCALE: 1"=1'-0" 30" 12" VARIES 8'-5" 3 12 2 4 2 4 2 4 2 4 2 4 2 4 GRADE TOP OF PORCH DECK TOP OF PORCH PLATE 2 8 2 8 2 8 2 8 2 8 2 12 HURRICANE STRAPS OR CLIPS @ EA. RAFTER SIMPSON OPTIONS 1: (2) H2.5, 2: MTS20, OR 3: H10 5V CRIMP METAL ROOF OVER 30# FELT OVER 5/8" CDX PLYWOOD OVER 3 1/2" S.I.P.S. (INSULATED PANEL) WITH 2X4 FIR STUDS @ 12" O.C. FOR ATTACHMENTS METAL DRIP EDGE 3X8'S @ 24" O.C. RAFTERS WITH TAPERED TAILS 1X6 FASCIA 24" OVERHANG 1X RANDOM WIDTH SOFFIT FINISH 2X8 BIRDBLOCK 5/4X4 TREATED PINE TONGUE AND GROOVE PORCH DECKING P.T. 2X8'S @ 16" O.C. PORCH JOISTS WITH JOIST HANGERS PAINTED FINISH TO MATCH EXISTING COTTAGE 12" CMU PIER WITH (2)#5'S VERTICAL REBAR. GROUT SOLID. CONCRETE FOOTING WITH (4)#5'S REBAR PITCH SOIL PITCH DECK CONTINUOUS TIE ROD FROM PIER EMBEDMENT TO TOP PLATE 1X10 BANDBOARD P.T. 2X12 SILL WITH TERMITE SHIELD NOTCHED AND DOUBLE BOLTED B A8 COVE SCREEN PORCH WITH BALCONY SECTION SCALE: 1"=1'-0" 5/4X4 TREATED PINE TONGUE AND GROOVE PORCH DECKING P.T. 2X8'S @ 16" O.C. PORCH JOISTS WITH JOIST HANGERS 2 8 2 8 PITCH DECK (3) P.T. 2X12'S GIRDER PAINTED FINISH TO MATCH EXISTING COTTAGE 12" CMU PIER WITH (2)#5'S VERTICAL REBAR. GROUT SOLID. CONCRETE FOOTING WITH (4)#5'S REBAR 8X8 SOLID WOOD COLUMN PITCH SOIL 1X10 BANDBOARD P.T. 2X12 SILL WITH TERMITE SHIELD NOTCHED AND DOUBLE BOLTED 2 12 2 12 2 12 2 12 ANCHOR BOLT (3) P.T. 2X10'S GIRDER 2 8 2 8 2 8 2 8 2 10 2 10 P.T. 2X8'S @ 16" O.C. PORCH JOISTS WITH JOIST HANGERS 2 4 2 42 42 4 PITCH DECK PITCH DECK P.T. 2X4'S DECKING OVER P.T. 2X4'S SLEEPERS OVER WATERPROOFING MEMBRANE OVER 3/4" CDX PLYWOOD P.T. 2X4 RAILS WITH P.T. 1X1 SCREEN STOPS INSECT SCREEN 8X10 SOLID WOOD BEAM 1X BANDBOARD 30" 12" COPPER GUTTER P.T. 6X6 POST NOTCHED AND DOUBLE BOLTED STAINLESS STEEL CABLE RAILING TEAK HANDRAIL VARIES 9'-7" GRADE TOP OF PORCH DECK TOP OF BALCONY DECK 8X8 SOLID WOOD COLUMN 8X10 SOLID WOOD BEAM 1X BANDBOARD ATTACHMENT 4 A9 SCHEDULES & DETAILS 1/8/21 DATE : MANUEL STUDIO, LLC Ansley Hester Manuel, Architect 104 Pritchard Street, Bluffton, South Carolina 29910 843.338.8932 cell manuel.studio@aol.com SHEET MANUEL STUDIO, LLC BLUFFTON, SC 100072 ANSLEY HESTER MANUEL BLUFFTON, SC 6887 ANILORACHTUOSFOETATS REGISTERED ARCHITECT ANILORACHTUOSFOETATS REGISTERED ARCHITECT ADDITIONS & RENOVATIONS TO THE MALPHRUS/FISHKIND RESIDENCE 114 PRITCHARD STREET BLUFFTON, S.C. S CYPRESS BOARD & BATTEN SIDING OVER HOUSEWRAP OVER 1/2" CDX PLYWOOD31 2" 31 2" INTERIOR FINISH AS PER SCHEDULE CORNER DETAIL SCALE: 1"=1'-0" D A9 WINDOW TRIM DETAIL @ SHIPLAP SCALE: 3"=1'-0" C PEAL AND SEAL AROUND OPENING FLASHING @ DRIPCAP 2X CYPRESS CAP 2X4 CYPRESS HEAD CASE 2X4 CYPRESS CASE 2X4 CYPRESS SILL A9 MARK WIDTH & HEIGHT TYPE REMARKS 1 3'-0"X7'-0" 4 PANEL W/ 12" SIDELITES EA. SIDE LITES WIDTH & HEIGHT TYPE A 2'-6" X 3'-6" FIXED LITES ALL EXTERIOR DOORS TO BE ALUMINUM CLAD (EXTERIOR), WOOD (INTERIOR) UNLESS OTHERWISE NOTED. ALL INTERIOR DOORS TO BE 5 PANEL COMPOSITE MATERIAL, MDF PREFERRED, UNLESS OTHERWISE NOTED. ALL GLASS TO BE IMPACT RESISTANT. 7/8" MUNTIN WIDTH AND SIMULATED DIVIDED LIGHT. ALL WINDOWS ARE WOOD INTERIOR AND CLAD EXTERIOR. 7/8" MUNTIN WIDTH AND SIMULATED DIVIDED LIGHT. ALL GLASS TO BE IMPACT RESISTANT. DP RATINGS ARE 35 IF MORE THAN 4' FROM CORNER & 45 IF WITHIN 4' FROM CORNER 2 3'-0"X7'-0" FULL GLASS DOOR SCHEDULE WINDOW SCHEDULE REMARKSMARK HANDRAIL DETAIL (TYPICAL) SCALE: 3"=1'-0" B A9 TEAK RAILING 3'-0" STAINLESS STEEL CABLE MAX OPENING 3@SIDELITE B 2'-10" X 6'-0" FIXED 6 6 OUTSWING 3 4 6 7 C D E 10 OUTSWING INSWING3'-0"X7'-0" SCREEN 3'-0"X7'-0" HALF GLASS 6 OUTSWING 5'-0"X7'-0" FRENCH DOUBLE 10 OUTSWING 2'-0"X6'-8" FULL GLASS 6 OUTSWING 2'-6" X 4'-0" FIXED 6 2'-0" X 3'-6" FIXED 6,1 2'-0"x 3'-0" ANGLED TRANSOM 2'-6" X 2'-6" FIXED 4 4" CONCRETE SLAB WITH 6X6 W1.4 X W1.4 WWF, DOUBLE 3' FROM EDGES, OVER 6 MIL VAPOR BARRIER W T 3 1/2" MIN. 1 1 T = 1/2 W W= 16" FOR 2-STORY W= 12" FOR ONE STORY (2) #5 REBAR THICKENED SLAB SCALE: 1"=1'-0" A A9 F 2'-0" DIA. FIXED ROUND WINDOW 5 2'-10"X7'-0" HALF GLASS 6 OUTSWING CYPRESS 1X4 CORNER BOARDS 3 3/4" ATTACHMENT 4 PLAN REVIEW COMMENTS FOR COFA-12-20-014811 Town of Bluffton Department of Growth Management 20 Bridge Street P.O. Box 386 Bluffton, South Carolina 29910 Telephone 843-706-4522 OLD TOWN Plan Type: Apply Date: Plan Status: Plan Address: 114 Pritchard St Street BLUFFTON, SC 29910 Historic District Active 12/04/2020 Plan PIN #:Case Manager: Katie Peterson Plan Description: A request by Ansley Manuel, on behalf of the owner, Patricia Ellen Malphrus, for review of a Certificate of Appropriateness to allow an addition of approximately 4,065 SF to the existing single-family structure of approximately 1,095 SF and to enclose the existing Carriage House of approximately 1,075 SF located at 114 Pritchard Street in the Old Town Bluffton Historic District and zoned Neighborhood Conservation-HD. STATUS: The Application will be heard at the January 4, 2020 HPRC meeting. Staff Review (HD) Submission #: 1 Recieved: 01/02/2021 Completed: 01/02/2021 Reviewing Dept. Complete Date StatusReviewer Approved with Conditions01/02/2021Growth Management Dept Review (HD) Katie Peterson Comments: 1. Windows are permitted to be square, rectangle, transom or sidelite. The plans propose a circular window on the east elevation and two right trapezoids on the west elevation. Windows must be revised to meet this requirement. (UDO 5.15.6.I.3.a.) 2. The UDO requires that porch posts shall be spaced no farther apart than they are tall. Columns are proposed as further apart on center than they are tall on the west elevation. The column placement must be revised to meet this requirement. (UDO 5.15.6.H.1.a. and Traditional Construction Patterns Section 52) 3. The first floor finish height must be 3 feet above the average adjacent sidewalk grade. While there is no sidewalk, the measurement shall be taken from the where the sidewalk would exist along Pritchard Street. Provide elevation of adjacent sidewalk grade to confirm that the finished floor is 36" above grade. (UDO Section 5.15.5.F.1.c.) 4. Porches are required to have a minimum height of 30 inches minimum from the adjacent grade to the top of stairs. The proposed height to top of stairs is 2' 3". The height of the porch must be increased to meet this requirement. (UDO Section 5.15.6.E.5.c.) 5. Provide additional information to clarify the finish of the stucco proposed on the foundation and chimney (tabby, sand-finished, and steel trowel are permitted). (UDO 5.15.6.G.1.a.) 6. Additional information must be provided on the walls behind the screened area on the west elevation as there is not enough information to complete review. (Applications Manual) 7. Building heights and widths shall be visually similar to those in the neighboring vicinity. As the addition to this structure is more than double the size of the existing structure, additional information showing the scale of the proposed in relation to the neighboring properties must be provided. (UDO 5.15.5.F.1.a.) 8. At time of final submittal, a landscape plan showing foundation buffers, canopy coverage, and street trees must be provided for review. (Applications Manual) 9. A Town of Bluffton Tree Removal Permit is required for any tree 14” (DBH) or greater located on a single family lot and proposed for removal (UDO Section 3.22.2.A.). 10. The site plan shows a carport proposed to be inclosed. No information on the carport was provided. Additional information must be provided for review. 11. Railings are permitted to be wood (termite resistant), painted or natural wrought or cast iron. The plans note the use of cable railings on the second story balcony on the west elevation. Railings must be revised to meet this standard. (UDO 5.15.6.H.2.d.) 12. In no case shall parking be located in front of a building. The plan proposed a new gravel drive, all of which is located in front of the primary structure. The driveway must be reconfigured to allow parking to be located on the side or the rear of the structure. (UDO 5.15.7.D.1.) 13. Provide additional information on the existing chimney to ensure the proposed has a visual relationship to the existing. Additionally, provide additional information on the proposed chimney cap. In keeping with masonry building technology, metal spark arrestors, exposed metal flues, or pre-fabricated chimney caps are not permitted. (5.15.6.E.8.d.) 14. At time of final submittal provide architectural details of the railing and baluster, a typical window detail, corner board/pilaster trim detail and sections through the eave and wall depicting the material configuration and dimensions. (Applications Manual) Approved with Conditions01/02/2021HPRC Review Katie Peterson 01/02/2021 Page 1 of 2 ATTACHMENT 5 Comments: 1. Overall building proportions and Individual building features shall have a proportional relationship with one another. For example, features such as porches, chimneys, cornices, windows and doors must be proportional to other features of the building as well as the overall building form. Based on the plans submitted, the existing structure does not have many elements which tie it to the proposed addition -possible chimney detailing and a metal roof. Provide detailing showing the relationship between the addition and the existing structure. Additionally, additions, connective wings, and outbuildings shall be secondary to the primary form. Provide additional information showing how the exiting structure will be prominent. (UDO 5.15.5.F.4. and UDO 5.15.5.F.4.a.) 2. At time of final submittal provide architectural details of the railing and baluster, a typical window detail, corner board/pilaster trim detail and sections through the eave and wall depicting the material configuration and dimensions. (Applications Manual) Approved with Conditions01/02/2021Watershed Management Review William Baugher Comments: 1. Small Construction Activities. The Town will require a Stormwater Affidavit with a SC DHEC NOI form D-0451 and implementation of the Construction Site BMPs found in Chapter 9 of the Stormwater Design Manual and the SC DHEC Erosion and Sediment Reduction standards and other Stormwater Management regulations, where applicable before Building Permits will be issued. Approved01/02/2021Addressing Review Nick Walton Comments: 1. Address remains 114 Pritchard Street. Approved01/02/2021Beaufort Jasper Water and Sewer Review James Clardy Comments: 1. BJWSA provides no comments. Approved01/02/2021Transportation Department Review - HD William Howard Comments: 1. No comments provided. Plan Review Case Notes: 01/02/2021 Page 2 of 2 ATTACHMENT 5 ATTACHMENT 6 ATTACHMENT 6 ATTACHMENT 6 ATTACHMENT 6 ATTACHMENT 6 6 Marianna Way, Building 4 – Certificate of Appropriateness Historic Preservation Commission HISTORIC PRESERVATION COMMISSION STAFF REPORT Department of Growth Management MEETING DATE: February 3, 2021 PROJECT: 6 Marianna Way APPLICANT: Court Atkins Architects, Inc. PROJECT MANAGER: Katie Peterson, AICP, Senior Planner APPLICATION REQUEST: The Applicant, Court Atkins Architects, Inc., on behalf of Herkus, LLC, requests that the Historic Preservation Commission approve the following application: 1. COFA-01-21-014892. A Certificate of Appropriateness to allow the construction of a new 2 1/2-story Mixed-Use building of approximately 5,272 heated square feet located at 6 Marianna Way, Building 4 in the Old Village Square development, in the Old Town Bluffton Historic District and zoned Neighborhood General – HD. INTRODUCTION: The Applicant is proposing the construction of a mixed-use structure located in the Old Town Bluffton Historic District. The proposed building, of approximately 5,272 SF, does not meet any of the building types for the Neighborhood General-HD zoning district, and therefore shall be reviewed as an Additional Building Type in accordance with Section 5.15.5.C. of the Unified Development Ordinance (UDO). This lot is located within the Old Village Square development plan, which was last amended in April of 2019 (DPA-06-17-011010). The main mass of the addition is under a two and a half-story side-facing gable with hip roofed cupola at the center. There are four dormers (two front and two rear facing) under shed roofs as well as a front portico under a gable roof and a rear portico under the same. A two-story front porch split by the portico and stair well runs the length of the front elevation under a shed roof. The two sides have balconies supported by brackets, accessed by the loft level units. The proposed materials include combination of horizontal lap siding on most of the structure with vertical board and batten in the rear portico gabled end. The roofs are a combination of shingle and standing seam metal and operable shutters have been proposed on all windows which can accept them. This project was presented to the Historic Preservation Review Committee for conceptual review at the January 20, 2021 meeting and comments were provided to the Applicant (See Attachment 6). February 3, 2021 Page 2 6 Marianna Way, Building 4 – Certificate of Appropriateness Historic Preservation Commission HISTORIC PRESERVATION COMMISSION ACTIONS: As granted by the powers and duties set forth in Section 2.2.6.E.2, the Historic Preservation Commission has the authority to take the following actions with respect to this application: 1. Approve the application as submitted by the Applicant; 2. Approve the application with conditions; or 3. Deny the application as submitted by the Applicant. It is important to note that the intent of Section 5.15 Old Town Bluffton Historic District of the Unified Development Ordinance (UDO) is that the Section be user friendly and informative to the residents and the members of HPC and is not intended to discourage creativity or force the replication of historic models. Rather, it is to set forth a framework in which the diversity that has always characterized Bluffton can continue to grow. The Section also defines guidelines for design and materials similar to that used on structures within the Old Town, and it is the charge of the HPC to assess the interpretation of these guidelines as they pertain to applications using the established review criteria. REVIEW CRITERIA & ANALYSIS: Town Staff and the Historic Preservation Commission are required to consider the criteria set forth in Section 3.18.3 of the UDO in assessing an application for a Certificate of Appropriateness – Historic District (HD). The applicable criteria are provided below followed by a Staff Finding(s) based upon review of the application submittals to date. 1. Section 3.18.3.B. Consistency with the principles set forth in the Old Town Master Plan. a. Finding. The application is consistent with the principles set forth in the Old Town Master Plan. The Old Town Master Plan states that, “The built environment, in particular the historic structures scattered throughout Old Town, should be protected and enhanced. While it is of great importance to save and restore historic structures, it is just as important to add to the built environment in a way that makes Old Town more complete.” The Applicant proposes to construct a new Mixed-Use building within the Old Town Bluffton Historic District, a locally and nationally designated historic district. The building has been designed to be sympathetic to the architectural character of the neighboring historic structures, so its addition to the architectural diorama will both protect the integrity of the existing historic structures and enhance the neighborhood by adding architectural variety. b. Finding. The Old Town Master Plan initiatives also include the adoption of a form-based code that included architectural standards for structures located within the Old Town Bluffton Historic District. These standards are included in Article 5 of the UDO. The new construction proposed as part of this request will be in conformance with those standards if the conditions noted in item 2 of this Section are met. February 3, 2021 Page 3 6 Marianna Way, Building 4 – Certificate of Appropriateness Historic Preservation Commission c. Finding. The Old Town Master Plan initiatives also promote preservation and protection of the legacy of the Old Town Bluffton Historic District through additions to the built environment which make Old Town more complete. The addition of the proposed structure will add to the district as well as help provide completeness to the neighborhood and overall district. 2. Section 3.18.3.C. The application must be in conformance with applicable provisions provided in Article 5, Design Standards. a. Finding. Town Staff finds that the design of the structure falls within the category of Additional Building Type within the Neighborhood General Historic District per Section 5.15.5.C. As the Commission with approval authority in accordance with article 2 of the UDO, the HPC has final approval authority on the appropriateness of an Additional Building Type within this zoning district. Town Staff requests the Historic Preservation Commission review and make a final determination regarding the appropriateness of the Additional Building Type. b. Finding. The building location is in the Old Village Square Development Planned area. As such, the setbacks for the structure are determined by the approved Development Plan rather than by Article 5 of the UDO. The setbacks, as proposed, are in compliance with the approved Development Plan. c. Finding. Town Staff finds that if the conditions noted below are met, the proposed addition will be in conformance with applicable provisions provided in Article 5: 1) Section 5.15.6.J. Roofs and Gutters. Shingle materials can be Metal or Asphalt “dimensional” type, Slate, Composite Slate. The project narrative notes the shingle material as fiberglass shingles. Shingles must be revised to be a permitted material. 2) Section 5.15.6.M. Shutters. Shutter dogs used may be standard “S” hook, rat-tail hooks, generally less decorative iron butterfly, or other style shutter dog typical of the Old Town Bluffton Historic District’s period of significance. No shutter dog profile was provided. Additional information on the shutter dog profile must be provided for review. 3) Section 5.15.6.N. Corners and Water Tables Corners. Corner boards shall project beyond siding material. They shall be mitered, rabbeted, or butt jointed (butt face to be on side of wall), shall be beaded or have ¼ round inset trim mold. A corner board detail was not provided. A corner board detail must be provided for review. 4) Section 5.3.7.E. Foundation Plantings. Except when a build-to line or minimum setback makes the provision of foundation plantings impractical, a foundation planting area at least 8 feet wide shall be maintained around all structures. The foundation planting shall February 3, 2021 Page 4 6 Marianna Way, Building 4 – Certificate of Appropriateness Historic Preservation Commission incorporate a mixture of trees, shrubs, and ground covers in order to soften the building façade. Foundation plantings shall not be required along any building elevation or portion thereof that contains only service and/or delivery area that are not visible from any roadway. The Landscape Plan associated with the approved development plan was based on the structures having 8’ colonnades wrapping the whole building. As the form of the structure has changed, the areas which were previously porches must show additional landscaping. 5) Section 5.15.5.F.4. Building Composition (Proportion, Alignment, Rhythm and Spacing). Overall building proportions and individual building features shall have a proportional relationship with one another, as well as the overall building form. The central portico appears under-scaled relative to the overall width of both buildings. Additionally, the glazing on the rear elevations appears to have under-scaled glazing resulting in large areas of blank walls. The proportions should be reconsidered to draw attention to the central entrance and increase glazing on the rear elevation. 3. Section 3.18.3.D. Consistency with the nature and character of the surrounding area and consistency of the structure with the scale, form and building proportions of the surrounding neighborhood. Finding. Town Staff finds the nature and character of the new construction to be consistent and harmonious with that of the surrounding neighborhood. The mass and scale of the structure is appropriate for its location and the architectural detailing, with revisions to address the items in section 2 above, will be sensitive to the neighboring properties. 4. Section 3.18.3.F. The historic, architectural, and aesthetic features of the structure including the extent to which its alteration or removal would be detrimental to the public interest. Finding. The Applicant seeks approval for the construction of a new structure in the Old Town Bluffton Historic District. The proposed plans are sympathetic in design to the neighboring historic and non-historic resources; therefore, the structure, as proposed, will have no adverse effect on the public interest. 5. Section 3.18.3.H. The application must comply with applicable requirements in the Applications Manual. Finding. The application has been reviewed by Town Staff and has been determined to be complete, however, additional information is required as noted in the conditions found below. Additionally, it should be noted that while the Landscape Plan has been updated for the area surrounding Building 3 and 4, the Landscape Plan associated with the Development Plan must still be implemented for the areas outside the scope of work for this application. February 3, 2021 Page 5 6 Marianna Way, Building 4 – Certificate of Appropriateness Historic Preservation Commission STAFF RECOMMENDATION: It is the charge of the HPC to assess and interpret the standards and guidelines set forth in the UDO as they pertain to applications using the review criteria established in the UDO and to take appropriate action as granted by the powers and duties set forth in Section 2.2.6.E.2. Town Staff finds that with the conditions noted below, the requirements of Section 3.18.3 of the Unified Development Ordinance have been met and recommends that the Historic Preservation Commission approve the application including the architectural plan set dated 2021.01.22 with the following conditions: 1. Per Section 5.15.6.J., the fiberglass shingles must be replaced with a permitted roof material. 2. Per Section 5.3.7.E. the landscape plan must be revised to show plantings in the areas which had porches shown on the Development Plan and now are not within the porch/building footprint. 3. Per Section 5.15.6.M., the shutter dog profile must be provided for review. 4. Per Section 5.15.6.N., a corner board detail must be provided for review. 5. Per Section 5.15.F.4. the proportion of the central portico relative to the overall width of the building should be restudied. 6. Per Section 5.15.F.4., the glazing on the rear elevation should be restudied to reduce large areas of blank walls on the rear elevation. ATTACHMENTS: 1. Location Map 2. Zoning Map 3. Application & Applicant Narrative 4. Site Plan & Elevations 5. Landscape Plan 6. HPRC Report Location Map - 6 Marianna Way 1 / 2 8 / 2 0 2 1 0 0 . 0 3 0 . 0 5 0 . 0 8 0 . 1 0 . 1 30 . 0 1 m i F I n f o L a y e r P a r c e l P r o p e r t y L in e s ATTACHMENT 1 Zoning Map - 6 Marianna Way 1 / 2 8 / 2 0 2 1 0 0 . 0 3 0 . 0 5 0 . 0 8 0 . 1 0 . 1 30 . 0 1 m i F I n f o L a y e r P a r c e l P r o p e r t y L in e s ATTACHMENT 2 TOWN OF BLUFFTON CERTIFICATE OF APPROPRIATENESS- OLD TOWN BLUFFTON HISTORIC DISTRICT (HD) APPLICATION Town of Bluffton Certificate of Appropriateness-Historic District Application Last Updated: 4/8/2014 Growth Management Customer Service Center 20 Bridge Street Bluffton, SC 29910 (843)706-4522 www.townofbluffton.sc.gov applicationfeedback@townofbluffton.com Applicant Property Owner Name: Name: Phone: Phone: Mailing Address: Mailing Address: E-mail: E-mail: Town Business License # (if applicable): Project Information (tax map info available at http://www.townofbluffton.us/gis/) Project Name: Conceptual: Final: Amendment: Project Location: Application for: New Construction Renovation/Rehabilitation/Addition Relocation or Demolition Zoning District: Acreage: Tax Map Number(s): Project Description: Minimum Requirements for Submittal 1. Full sized copies and digital files of the Site Plan(s). One (1) set for Conceptual, two (2) sets for Final 2. Full sized copies and digital files of the Architectural Plan(s). One (1) set for Conceptual, two (2) sets for Final 3. Project Narrative describing reason for application and compliance with the criteri a in Article 3 of the UDO. 5. All information required on the attached Application Checklist. 6. An Application Review Fee as determined by the Town of Bluffton Master Fee Schedule. Checks made payable to the Town of Bluffton. Note: A Pre-Application Meeting is required prior to Application submittal. Disclaimer: The Town of Bluffton assumes no legal or financial liability to the applicant or any third party whatsoever by approving the plans associated with this permit. I hereby acknowledge by my signature below that the foregoing application is complete and accurate and that I am the owner of the subject property. As applicable, I authorize the subject property to be posted and inspected. Property Owner Signature: Date: Applicant Signature: Date: For Office Use Application Number: Date Received: Received By: Date Approved: TOWN OF BLUFFTON CERTIFICATE OF APPROPRIATENESS- OLD TOWN BLUFFTON HISTORIC DISTRICT (HD) APPLICATION PROCESS NARRATIVE Town of Bluffton Certificate of Appropriateness- Historic District Application Last Updated: 4/8/2014 The following Process Narrative is intended to provide Applicants with an understanding of the respective application process, procedures and Unified Development Ordinance (UDO) requirements for obtaining application approval in the Town of Bluffton. While intended to explain the process, it is not intended to repeal, eliminate or otherwise limit any requirements, regulations or provisions of the Town of Bluffton’s UDO. Compliance with these procedures will minimize delays and assure expeditious application review. Step 1. Pre-Application Meeting Applicant & Staff Prior to the filing of a Certificate of Appropriateness-HD Application, the Applicant is required to consult with the UDO Administrator at a Pre-Application Meeting for comments and advice on the appropriate application process and the required procedures, specifications, and applicable standards required by the UDO. Step 2. Application Check-In Meeting – Concept Review Submission Applicant & Staff Upon receiving input from Staff at the Pre-Application Meeting, the Applicant may submit a Concept Review Submission of the Certificate of Appropriateness Application with the required submittal materials during an Application Check-In Meeting where the UDO Administrator will review the submission for completeness. Step 3. Review by UDO Administrator and HPC Staff If the UDO Administrator determines that the Concept Review Submission of the Certificate of Appropriateness-HD Application is complete, it shall be forwarded to the Historic Preservation Review Committee. The Review Committee shall review the application and prepare written comment for review with the Applicant. Step 4. Historic Preservation Review Committee Applicant, Staff & Historic Preservation Review Committee A public meeting shall be held with the Applicant to the review the Review Committee’s Staff Report and discuss the application. The Review Committee shall review the Concept Review Submission for compliance with the criteria and provisions in the UDO. The Applicant will be given the opportunity to address comments, if any, and resubmit the application materials to proceed to the Final Review Submission. Step 5. Application Check-In Meeting - Final Review Submission Applicant & Staff The Applicant shall submit the completed Final Review Submission of the Certificate of Appropriateness Application with the required submittal materials during a mandatory Application Check-In Meeting where the UDO Administrator will review the submission for completeness. Step 6. Historic Preservation Commission Meeting Applicant, Staff & Historic Preservation Commission A public meeting shall be held with the Applicant where the HPC shall review the Final Application materials of the Certificate of Appropriateness-HD Application for compliance with the criteria and provisions in the UDO. The HPC may approve, approve with conditions, or deny the application. Step 7. Issue Certificate of Appropriateness Staff If the HPC approves the Certificate of Appropriateness-HD Application, the UDO Administrator shall issue the Certificate of Appropriateness-HD. TOWN OF BLUFFTON CERTIFICATE OF APPROPRIATENESS – HISTORIC DISTRICT PROJECT ANALYSIS Last Updated: 4/8/2014 In accordance with the Town of Bluffton Unified Development Ordinance (UDO), the following information shall be included as part of a Certificate of Appropriateness application submitted for review by the Historic Preservation Commission (HPC) and the Historic Preservation Review Committee . The use of this checklist by Town Staff or the Applicant shall not constitute a waiver of any requirement contained in the UDO. 1. DESIGN REVIEW PHASE CONCEPTUAL REVIEW FINAL REVIEW 2. SITE DATA Identification of Proposed Building Type (as defined in Article 5): Building Setbacks Front: Rear: Rt. Side: Lt. Side: 3. BUILDING DATA Building Description (Main House, Garage, Carriage House, etc.) Existing Square Footage Proposed Square Footage Main Structure Ancillary Ancillary 4. SITE COVERAGE Impervious Coverage Coverage (SF) Building Footprint(s) Impervious Drive, Walks & Paths Open/Covered Patios A.TOTAL IMPERVIOUS COVERAGE B.TOTAL SF OF LOT % COVERAGE OF LOT (A/B= %) 5. BUILDING MATERIALS Building Element Materials, Dimensions, and Operation Building Element Materials, Dimensions, and Operation Foundation Columns Walls Windows Roof Doors Chimney Shutters Trim Skirting/Underpinning Water table Cornice, Soffit, Frieze Corner board Gutters Railings Garage Doors Balusters Green/Recycled Materials Handrails TOWN OF BLUFFTON CERTIFICATE OF APPROPRIATENESS – HISTORIC DISTRICT APPLICATION CHECKLIST Town of Bluffton Applications Manual 2 of 3 Last Updated: 4/8/2014 Note: Certificate of Appropriateness application information will vary depending on the activities proposed. At a minimum, the following items (signified by a grayed checkbox) are required, as applicable to the proposed project. Concept Final BACKGROUND INFORMATION. COMPLETED CEFTIFICATE OF APPROPRIATENESS-HD APPLICATION: A competed and signed application providing general project and contact information. PROPERTY OWNER CONSENT: If the applicant is not the property owner, a letter of agency from the property owner is required to authorize the applicant to act on behalf of the property owner. PROJECT NARRATIVE: A detailed narrative describing the existing site conditions and use, the proposed development intent with proposed uses and activities that will be conducted on the site. Include a description of the proposed building type and proposed building materials as permitted in Article 5. DEED COVENANTS/RESTRICTIONS: A copy of any existing deed covenants, conditions and restrictions, including any design or architectural standards that apply to the site. ADDITIONAL APPROVALS: A written statement from the Declarant of any deed covenants, conditions, or restrictions and/or the Review Body of any design or architectural standards that the current design has been reviewed for consistency with the established restrictions/design principles and approved. Concept Final SITE ASSESSMENT. LOCATION MAP: Indicating the location of the lot and/or building within the Old Town Bluffton Historic District with a vicinity map. PROPERTY SURVEY: Prepared and sealed by a Registered Land Surveyor indicating the following, but not limited to:  All property boundaries, acreage, location of property markers, name of county, municipality, project location, and parcel identification number(s);  Municipal limits or county lines, zoning, overlay or special district boundaries, if they traverse the tract, form a part of the boundary of the tract, or are contiguous to such boundary;  All easements of record, existing utilities, other legal encumbrances, public and private rights-of-way, recorded roadways, alleys, reservations, and railways;  Existing watercourses, drainage structures, ditches, one-hundred (100) year flood elevation, OCRM critical line, wetlands or riparian corridors top of bank locations, and protected lands on or adjacent to the property;  Location of existing buildings, structures, parking lots, impervious areas, public and private infrastructure, or other man-made objects located on the development property; and  North arrow, graphic scale, and legend identifying all symbology. SITE PLAN: Showing layout and design indicating, but not limited to:  All property survey information showing all building footprint(s) with finish floor elevations, setbacks and build-to lines, building location(s), building orientation(s);  Overall lot configuration depicting ingress/egress, circulation, driveways, parking areas, patios, decks, pools, hardscape, service yards and all other site amenities;  Pedestrian circulation elements and ensuring design shows ADA accessibility compliance. Location, layout, and number of vehicular and bicycle parking spaces bicycle parking, and ensuring design shows ADA accessibility compliance; and  Include detailed dimensions as necessary and appropriate to demonstrate compliance with all applicable standards and requirements. TOWN OF BLUFFTON CERTIFICATE OF APPROPRIATENESS – HISTORIC DISTRICT APPLICATION CHECKLIST Town of Bluffton Applications Manual 3 of 3 Last Updated: 4/8/2014 SIGN AND RETURN THIS CHECKLIST WITH THE APPLICATION SUBMITTAL ALL SUBMITTALS MUST BE COLLATED AND FOLDED TO 8-1/2” X 11” By signature below I certify that I have reviewed and provided the submittal items listed above . Further, I understand that failure to provide a complete, quality application or erroneous information may result in the delay of processing my application(s). ______________________________________________________ _______________________ Signature of Property Owner or Authorized Agent Date ______________________________________________________ Printed Name PHOTOS: Comprehensive color photograph documentation of the property, all exterior facades, and the features impacted by the proposed work. If digital, images should be at a minimum of 300 dpi resolution. Concept Final ARCHITECTURAL INFORMATION. CONCEPTUAL ARCHITECTURAL SKETCHES : Sketch of plans, elevations, details, renderings, and/or additional product information to relay design intent. FLOOR/ROOF PLANS : Illustrate the roof and floor plan configurations. Include all proposed uses, walls, door & window locations, overall dimensions and square footage(s). ELEVATIONS: Provide scaled and dimensioned drawings to i llustrate the exterior appearance of all sides of the building(s). Describe all exterior materials and finishes and include all building height(s) and heights of appurtenance(s) as they relates to adjacent grade, first floor finished floor elevations, floor to ceil ing height for all stories, existing and finish grades for each elevation. ARCHITECTURAL DETAILS : Provide scaled and dimensioned drawings to show the configuration and operation of all doors, windows, shutters as well as the configuration and dimensional information for columns and porch posts, corner boards, water tables, cupolas and roof appurtenances, gutters and downspouts, awnings, marquees, balconi es, colonnades, arcades, stairs, porches, stoops and railings. MANUFACTURER’S CUT SHEET/SPECIFICATIONS : Include for all atypical building elements and materials not expressly permitted by Article 5 of the UDO with sizes and finishes noted. Concept Final LANDSCAPE INFORMATION. TREE REMOVAL PLAN: A site plan indicating location, species, and caliper of existing trees and trees to be removed. LANDSCAPE PLAN: Plan must include proposed plant materials including names, quantities, sizes and location, trees to be removed/preserved/relocated, areas of planting, water features, extent of lawns, and areas to be vegetated. Plant key and list to be shown on the lan dscape plan as well as existing and proposed canopy coverage calculations. Concept Final ADDITIONAL REQUIRED INFORMATION (Single-Family Residential Excluded). PRELIMINARY DEVELOPMENT PLAN APPLICATION: Submit a Preliminary Development Plan Application along with all required submittal items as depicted on the application checklist. January 20, 2021 Katie Peterson, Senior Planner Town of Bluffton Growth Management Bluffton, SC 29910 Project: Building 4 at Old Village Square Re: HPC submittal Katie, Please find the documents enclosed for the HPC to consider an alternate building design for Building #4 at the Old Village Square development. Due to design and construction constraints outside the control of the Owner, we were engaged to re-design the exterior envelope, while maintaining or reducing the previously approved square footage, width, length, and height. As discussed, the building will be maintained as an “Additional Building” type and reviewed as such. Please note, the approved development plan is a horizontal regime and thus, the site approvals and characteristics/parameters are unique (i.e. setbacks) to this project. Based upon the HPRC review and staff comments; the design drawings have been modified. Please see the specific comment responses below: Growth Management 1) The first floor of each building has been redesigned to accommodate a rentable commercial office space in order to qualify as a mixed-use building type. 2) Notices will be sent once the Town provides the list of adjacent property owners. 3) An updated application has been provided. 4) The building is submitted as an “additional building type” and to be reviewed as such. 5) The center gable on the porch was maintained as previously submitted based upon the HPRC discussion. The rear gable has been maintained as well due to head height requirements in the stair. The rear elevation has ample glazing and fenestration. 6) This building is a mixed-use (residential and commercial) structure noted as an “additional building type.” 7) The side porches have been removed. A balcony was added on the third floor. 8) The side porches have been removed. 9) The side porches have been removed. Services yard have been added on the sides. 10) The fiberglass doors have been changed to metal-clad. 11) The clipped gable has been removed. 12) The roof material has been changed to all fiberglass shingle except at the dormers and porch porch 13) While the originally approved development has 4 nearly identical buildings, modifications will be made to 10 Marianna Way to create visual distinction. 14) Details had been provided. Building Safety Review 1) Acknowledged. HPRC Review 1) Service yards are located on the side and rear of the building . 2) See calculations showing 70% or less for the ½ story area calculation. Calculations have been updated. 2 Kind Regards, James Atkins, Architect EXISTING BUILDING 2 WM SL 23,429 sq. ft. 0.54 acres PARCEL 746 REFERENCE PLAT ASPHALT IN NAIL N/F DEVSU, LLC N/F SADIE BRUIN PATRICK BLUE WATER INVESTMENT GROUP INC. N/F N/F WILLIAM G. MARTINI & VERONICA L. MARTINI PARCEL 1569 PARCEL 1585 JOHN P. TREADAWAY N/F PARCEL 1570 PARCEL 497 PARCEL 164B PARCEL 161 SHULTS ROAD 40' R/W IPF 1/2" REBAR 1/2" IPF REBAR IPF 1/2" REBAR IPF 1/2" REBAR IPF 1" PIPE 3"X3" CMF 3"X3" CMF 3"X3" CMF IPF 1" PIPE DYH WV BUILDING 4 BUILDING 5 FUTURE BLDG. UP MAY RIVER ROAD SHULTS ROAD N UP OLD VILLAGE SQUARE JANUARY 15, 2021 © COPYRIGHT 2021 COURT ATKINS GROUP 1 SITE PLAN SCALE 1/32" : 1'-0" ATTACHMENT 4 NOTE TO GENERAL CONTRACTORS: THESE DRAWINGS HAVE BE EN PRODUCED UNDER A LIMITED SERVICES AGREEMENT BETWEEN THE OWNE R/OWNER'S REPRESENTATION AND COURT ATKINS ARCHITECTS, INC. THEY ARE TO BE USED FOR DESIGN INTENT AND IN COORDINATION WITH SUPPLEMENT E NGINEERING DOCUMENTS. THE ARCHITECT'S DRAWINGS CANNOT STAND ALONE AS CONSTRUCTION DOCUMENTS. SEE STRUCTURAL ENGINEERING DOCUMENTS FOR STRUCTURAL CONNECTION TECHNIQUES, CALCULATIONS REQUIRED BY CODE, CODE COMPLIANCE INSTRUCTIONS FOR WALL AND ROOF CONSTRUCTION, AND TI E DOWN REQUIREMENTS. SEPARATE MECHANICAL, ELECTRICAL, AND PLUMBING ENGINEERING DOCUMENTS MAY BE PROVIDED, WHICH INDICATE REQUIRED SERVICE AN D RISER DIAGRAMS, CALCULATIONS AND INSTALLATION SPECIFICATIONS BEYOND THE ARCHITECTS BASIC LAYOUT AND SELECTIONS SUGGESTIONS. SEPARATE CIVIL ENGINEERING DOCUMENTS MAY BE PROVIDE D, WHICH INDICATE ADDITIONAL SITE PLANNING, DRAINAGE, AND OTHER RELATED SITE WORK REQUIREMENTS. SELECTIONS NOT INCLUDED IN THESE DOCUMENTS WILL BE COORDINATED BY THE OWNER/ OWNER'S REPRESENTATIVES. BY APPLYING FOR A BUILDING PERMIT AND/OR CONSTRUCTI NG THE PROJECT REPRESENTED HEREIN, THE OWNER AGREES TO LIMIT THE L IABILITY OF THE ARCHITECT TO THE OWNER OF THE PROJECT FOR ALL AND ANY CLAIMS, LOSSES, DAMAGES OR ANY NATURE WHATSOEVER, OR CLAIMS OF EXPE NSES FOR ANY SUCH ITEMS TO THE ARCHITECTS TOTAL COMPENSATION FOR SERVICES RENDERED HEREIN. THESE DOCUMENTS ARE THE WORK INSTRUMENTS OF THE ARCHITECT AND HAVE BEEN PREPARED SPECIFICALLY AND SOLELY FOR THE PROJECT NAMED HEREIN. THEY ARE NOT SUITABLE FOR USE ON OTHER PROJECTS OR IN OTHER LOCATIONS WITHOUT THE PARTICIPATION OF THE ARCHITECT. REPRODUCTION IS STRICTLY PROHIBITED. THE ARCHITECT SHALL BE DEEMED THE AUTHOR AND OWNER OF THESE DOCUMENTS AND SHALL RETAIN COMMON LAW, STATUTORY AND OTHER RESERVED RIGHTS, INCLUDING THE COPYRIGHT. THE ARCHITECT HAS NOT BEEN CONTRACTED TO PERFORM CONSTRUCTION ADMINISTRATION/ ON-SITE OBSERVATION FOR THIS PROJEC T. FOR DIMENSIONS NOT SHOWN OR IN QUESTION, THE CONTRA CTOR WILL REQUEST CLARIFICATION FROM THE ARCHITECT BEFORE PROCEEDING. CONTRACTOR WILL VERIFY ALL EXISTING CONDITIONS IN T HE FIELD- ANY DISCREPANCIES WILL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT. THE CONTRACTOR SHALL MAINTAIN AT THE SITE OF THE WORK, A SET OF RECORD DRAWINGS. THE CONTRACTOR SHALL RECORD ALL CHANGES AND DEVIATIONS FROM THE DRAWINGS ON THIS "AS-BUILT" SET, WHICH SHA LL BE UPDATED AT LEAST EVERY OTHER WEEK. AT THE CLOSE OF THE JOB, THE CONTRACTOR SHALL PROVIDE ONE COMPLETE SET OF ALL AS-BUILT INFORMATION TO THE ARCHITECT IN CLEAR AND LEGIBLE FORMAT. SIGNS SHALL BE LIMITED TO THE PROJECT IDENTIFICATIO N SIGN. THE IDENTIFICATION SIGN SHALL IDENTIFY THE PROJECT, THE ARCHITECT AND THE CONTRACTOR. INFORMATION CONTAINED ON THESE DRAWINGS IS PROVIDED FOR THE CONVENIENCE OF THE GENERAL CONTRACTOR IN EXECUTING THE WORK. EVERY ATTEMPT HAS BEEN MADE TO PROVIDE COMPLETE AND ACCURATE REPRESENTATIONS OF SUCH CONDITIONS. WHEN ARCHITECTURAL DRAWINGS ARE IN CONFLICT WITH EN GINEERING DRAWINGS THE GENERAL CONTRACTOR SHALL REQUEST CLARIFICATION FROM THE ARCHITECT BEFORE PROCEEDING. GENERAL NOTES THIS WRITTEN NOTICE REQUIRED BY SOUTH CAROLINA REGU LATIONS TO THE PERMITTING AUTHORITY AND BUILDING OWNER THAT THE AR CHITECTS WILLIAM COURT AND JAMES ATKINS HAVE NOT BEEN HIRED TO PROVIDE MINIMUM CONSTRUCTION ADMINISTRATION SERVICES ON THE FOLLOWI NG PROJECT. RESIDENTIAL (R) & BUSINESS (B) MIXED USE OCCUPANCY: REGULATION 11-12.B.4 AND 5 STATE: (1) ON A PROJECT WHERE A BUILDING PERMIT HAS BEEN ISSUED AND THE SEALING ARCHITECT AND THE FIRM OF RECORD HAVE NOT BEEN ENGAGED TO PERFORM AT LEAST MINIMUM CONSTRUCTION ADMINISTRATION SERVICES, AS DEFINED IN SUBSECTION (5) BELOW, THE SEALING ARCHITECT AND FIRM MUST REPORT TO THE PERMITTING AUTHORITY AND THE BUILDING OWNER THAT HE AND THE FIRM HAVE NOT BEEN SO ENGAGED. (2) THE MINIMUM CONSTRUCTION ADMINISTRATION SERVICE S EXPECTED OF THE SEALING ARCHITECT AND FIRM DEEMED NECESSARY TO PROTECT THE HEALTH, SAFETY, AND WELFARE OF THE PUBLIC SHALL BE PERIODIC SITE OBSERVATIONS OF THE CONSTRUCTION PROGRESS AND QUALITY, REVIEW OF CONTRACTOR SUBMITTAL DATA AND DRAWINGS, AND REPORTING TO THE BUILDING OFFICIAL AND OWNER ANY VIOLATIONS OF CODES OR SUBSTANTIAL DEVIATIONS F ROM THE CONTRACT DOCUMENTS WHICH THE ARCHITECT OBSERVED. CONSTRUCTION ADMINISTRATION OCCUPANCY CLASSIFICATION: RESIDENTIAL (R-2) & BUINESS (B) MIXED OCCUPANCY: YES X NO SEPARATION 0 HR. CONSTRUCTION TYPE: I-A I-B II-A II-B III-A III-B IV V-A V-B MIXED CONSTRUCTION: YES NO X TYPE SPRINKLERED: YES X NO FIRE DISTRICT: YES _______ NO X BUILDING HEIGHT: 37' - 8" AFF NUMBER OF STORIES: 2 1/2 MEZZANINE: YES _______ NO X HIGH RISE: YES _______ NO X BUILDING DATA PROJECT DESCRIPTION: CONSTRUCTION OF A 2 1/2 STORY MULTI-FAMILY / OFFICE BUILDING BUILDING CONSTRUCTION: LOAD BEARING WOOD STUDS, WOOD ROOF TRUSSES & CONCRETE SLAB ON GRADE. CATAGORY ALLOWABLE AC TUAL HEIGHT (RES.): 40'-0" 37'-8" STORIES(RES.): 3 ST. 2 1/2 ST. AREA PER FLOOR: 9,000 SF 2,604 SF AREA TOTAL: 18,000 SF 7,197 SF AREA INCREASE? Yes _______ No X HEIGHT INCREASE? Yes _______ No X RESIDENTIAL (R): 5,092 SF / 200 SQ.F.T (GROSS) PER PERSON = 26 TOTAL (R) OCCUPANCY: 26 OCCUPANTS BUSINESS (B): 180 SF / 150 SQ.F.T (GROSS) PER PERSON = 2 TOTAL (R) OCCUPANCY: 2 OCCUPANTS TOTAL OCCUPANCY ON SITE: 37 OCCUPANTS NUMBER OF EXITS: REQUIRED PROVIDED 2 2 EXIT ACCESS DESIGN REQUIREMENTS, PER MOST RESTRICTIVE CATAGORY MAX. ALLOWABLE ACTUAL MAX EXIT ACCESS TRAVEL DISTANCE (IBC TABLE 1017.2) : 250 FT (R-2) & 300 FT (B) XXX FT (R-2) & XXX FT (B) COMMON PATH OF TRAVEL (IBC TABLE 1006.2.1) 125 FT (R-2) & 100 FT (B) XXX FT (R-2) & XXX FT (B) DEAD END CORRIDOR (IBC TABLE 1020.4) 20 FT XX FT ALLOWABLE HEIGHT & AREA (PER IBC TABLE 504.3 & 504.4 & 506.2): OCCUPANT LOAD (IBC TABLE 1004.5): EXITS (IBC TABLE 1006.3.2) TRAVEL DISTANCE MINIMUM REQUIRED PLUMBING FIXTURES: PER IBC TABLE 2902.1 FIRE SEPARATION IBC TABLE 601, 602, 508.3.3 REQ'D HR DETAIL # % WALL OPENING UL RATED ASSEMBLY PRIMARY STRUCTURAL FRAME BEARING WALLS: EXTERIOR INTERIOR ALL INTERIOR WALLS AND CEILING FINISHES TO COMPLY WITH IBC-2018, TABLE 803.13 IBC TABLE 803.13 GROUP SPRINKLERED UNSPRINKLERED VERT. EXITS / EXIT PASSAGE- WAYS EXIT ACCESS CORRIDORS / OTHER EXITS ROOMS & ENCLOSED SPACES VERT. EXITS / EXIT PASSAGE- WAYS EXIT ACCESS CORRIDORS / OTHER EXITS ROOMS & ENCLOSED SPACES RESIDENTIAL (R-2) TOTAL OCCUPANCY FOR RESIDENTIAL (R-2) = X PERSONS TOTAL OCCUPANCY FOR RESIDENTIAL (B) = X PERSONS OCCUPANCY, 50% MALE / 50% FEMALE XX MALE OCCUPANTS & XX FEMALE OCCUPANTS (R-2) XX MALE OCCUPANTS & XX FEMALE OCCUPANTS (B) PLUMBING CALCULATIONS 0 PROJECT INFORMATION OWNER CONTACT MR. HOUSSAM ABOUKHATER 10 ANSON PARK ROAD E BLUFFTON, SC, 29910 (603) 205-5555 PH STRUCTURAL ENGINEER TBD MECHANICAL, PLUMBING & FIRE PROTECTION TBD ELECTRICAL ENGINEER TBD PROJECT TEAM ARCHITECT COURT ATKINS ARCHITECTS, INC. 32 BRUIN ROAD P.O. BOX 3978 BLUFFTON, SC 29910 (843) 815-2557 PH (843) 815-2547 FAX GENERAL CONTRACTOR TBD LANDSCAPE ARCHITECT TBD CIVIL ENGINEER TBD DISCIPLINE NAME LICENSE NO. TELEPHONE NO. ARCHITECTURAL JAMES C. ATKINS SC #6743 (843) 815-25 57 STRUCTURAL TBD -- (XXX) XXX-XXXX ELECTRICAL TBD -- (XXX) XXX-XXXX PLUMBING TBD -- (XXX) XXX-XXXX MECHANICAL TBD -- (XXX) XXX-XXXX CIVIL TBD -- (XXX) XXX-XXXX LANDSCAPE TBD -- (XXX) XXX-XXXX DESIGNER OF RECORD TOTAL GROSS AREA (H/C): 5,272 SF (H/C) GROSS BUILDING AREA LEVEL 01: HEATED & COOLED 1,984 SF LEVEL 02: HEATED & COOLED 1,984 SF LOFT LEVEL: HEATED & COOLED 1,304 SF NAME OF PROJECT: OLD VILLAGE SQUARE - BUILDINGS ADDRESS: 6 MARIANNA WAY BLUFFTON, SC 29910 PROPOSED USE: RESIDENTIAL (R-2) & BUSINESS (B) OWNER CONTACT: MR. HOUSSAM ABOUKHATER CODE ENFORCEMENT JURISDICTION: TOWN OF BLUFFTON INTERNATIONAL BUILDING CODE (IBC): 2018 INTERNATIONAL MECHANICAL CODE: 2018 INTERNATIONAL PLUMBING CODE: 2018 THE NATIONAL ELECTRICAL CODE: 2017 INTERNATIONAL FUEL GAS CODE: 2018 INTERNATIONAL FIRE CODE: 2018 INTERNATIONAL ENERGY CONSERV. CODE: 2009 ICC/ANSI A117.1: 2017 INTERNATIONAL RESIDENTIAL CODE 2018 0 0 NON-BEARING WALLS: EXTERIOR INTERIOR 0 0 FIRE SEPARATION WALLS: EXTERIOR INTERIOR FLOOR CONSTRUCTION 0 ROOF CONSTRUCTION 0 SHEET INDEX HEYWARD ST. SC HW Y 46 PROJECT LOCATION VICINITY MAP - N.T.S. NORTH W S E COLUMN GRID REFERENCE A ROOM 150 SF Comments ROOM TAG LEVEL 1 100' - 0" LEVEL/ELEVATION REFERENCE EXTERIOR ELEV. SYMBOLA3.0 1 INTERIOR ELEVATION SYMBOL A7.0 1 A4.0 1 BUILDING SECTION A5.0 1 WALL SECTION A5.0 1 DETAIL SECTION CALLOUT A5.0 1 ENLARGED PLAN/ DETAIL CALLOUT 1 REVISION CLOUD & TAG WINDOW TAG DOOR TAG101.1 SYMBOL KEY H 0 0 SCHULTS ST. GOETHE RD. PROMENADE ST. B LUFFTON RD. BOUNDRY ST. CALHOUN ST. DUBOIS LN. WHARF ST. BUSINESS (B) C C C B B C B C C A B C REQUIRED FIXTURE RATIO REQUIRED FIXTURES FIXTURES PROVIDED ITEM MEN WOMEN MEN WOMEN MEN WOMEN UNISEX TOTAL WATER CLOSETS TOTAL LAVATORIES DRINKING FOUNTAINS OTHER NOT REQUIRED (R-2) 1 PER 100 (B) 1 KITCHEN SINK PER DWELLING UNT; 1 AUTOMATIC CLOTHES WASHER CONNECTION PER DWELLING UNIT 1 (R-2) & 1 (B) 1 (B) 1 PER DWELLING UNIT (R-2) & 1 PER 25 FOR THE FIRST 50 & 1 PER 50 FOR THE REMAINDER EXCEEDING 50 (B) 1 (B) 1 KITCHEN SINK PER DWELLING UNT; 1 AUTOMATIC CLOTHES WASHER CONNECTION PER DWELLING UNIT NOT REQUIRED (R-2) 1 FIXTURE (B) 1 (R-2) & 1 (B) 1 (R-2) & 1 (B) 1 PER DWELLING UNIT (R-2) & 1 PER 40 FOR THE FIRST 80 & 1 PER 80 FOR THE REMAINDER EXCEEDING 80 (B) 1 (R-2) & 1 (B) 1 (R-2) & 1 (B) 1 (R-2) & 1 (B) 1 (R-2) & 1 (B) 1 (R-2) & 1 (B) NOT REQUIRED (R-2) 1 FIXTURE (B) BATH TUBS / SHOWERS 1 PER DWELLING UNIT (R-2) NOT REQUIRED (B) 1 FIXTURE (R-2) NOT REQUIRED (B) 1 FIXTURE (R-2) NOT REQUIRED (B) I SSUE P ROJECT INFO S HEET TITLE D ate P roject No. COPYRIGHT 2019 COURT ATKINS GROUP - THIS DRAWING IS THE PROPERTY OF THE ARCHITECT AND IS NOT TO BE REPRODUCED IN WHOLE OR IN PART BY ANY MEANS OR METHOD WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ARCHITECT. ANY UNAUTHORIZED REPRODUCTION OR REUSE OF THESE DOCUMENTS WILL RESULT IN LEGAL ACTION. POST OFFICE BOX 3978 BLUFFTON, SC 29910 PH: 843.815.2557 FX: 843.815.2547 WWW.COURTATKINS.COM © 1/22/2021 4:30:21 PM 2 021.01.22 2 0-0 95 A0.0 O LD VILLAGE SQUARE - B UILDING 4 6 MARIANNA WAY B LUFFTON, SC 29910 FINAL HPC SUBMITTAL OLD VILLAGE SQUARE - BUILDING 4 6 MARIANNA WAY BLUFFTON, SC 29910 C OVER SHEET NO. REV. DATE DESCRIPTION ARCHITECTURAL SHT. # SHEET NAME ISSUE DATE DRAWING SET A0.0 COVER SHEET 01/22/2021 HPC A1.0 SITE PLAN 01/22/2021 HPC A2.1 FIRST FLOOR PLAN 01/22/2021 HPC A2.2 SECOND FLOOR PLAN 01/22/2021 HPC A2.3 LOFT LEVEL PLAN 01/22/2021 HPC A2.4 ROOF PLAN 01/22/2021 HPC A3.0 FRONT EXTERIOR ELEVATION 01/22/2021 HPC A3.1 RIGHT SIDE EXTERIOR ELEVATION 01/22/2021 HPC A3.2 REAR EXTERIOR ELEVATION 01/22/2021 HPC A3.3 LEFT SIDE EXTERIOR ELEVATION 01/22/2021 HPC A5.0 DETAILS 01/22/2021 HPC A5.1 DETAILS 01/22/2021 HPC A6.0 DOOR AND WINDOW SCHEDULE 01/22/2021 HPC ATTACHMENT 4 UP Washer DryerWasherDryer Range Range Refrigerator Refrigerator A3.11 A3.0 1 A3.2 1 A3.3 1 BUSINESS OFFICE VESTIBULE 1 OFFICE BATH BEDROOM 1 VESTIBULE 2BATHROOM 1 LAUNDRY KITCHEN / DINING & LIVING CLOSET 2 CLOSET 1 BEDROOM 1 VESTIBULE 2 BATHROOM 1 LAUNDRYBATHROOM 2 VESTIBULE 1 BEDROOM 2 KITCHEN / DINING & LIVINGCLOSET 2 CLOSET 1 ELEC. RM. FIRE RISER OPEN AIR VESTIBULE OPEN AIR PORCH 9' - 11 3/8" 14' - 0 5/8" 8' - 0" 8' - 0" 8' - 0" 14' - 0 5/8" 9' - 11 3/8" 72' - 0" 1' - 10" 10' - 0 1/2" 31' - 0" 4' - 9 3/8" 2 5/8" 47' - 10 1/2" 2' - 0" 27' - 3 1/2" 13' - 5" 27' - 3 1/2" 2' - 0" 72' - 0" 1' - 10" 10' - 0 1/2" 31' - 0" 4' - 9 3/8" 2 5/8" 47' - 10 1/2" SERVICE YARD SERVICE YARD 7 1/2" 7' - 7 1/4" 1' - 10" 8' - 5 1/4" 1' - 10" 6' - 11 3/4" 7 1/2" 1' - 10" 8' - 6" 1' - 10" 7 1/2" 6' - 11 3/4" 1' - 10" 8' - 5 1/4" 1' - 10" 7' - 7 1/4" 7 1/2" 7 1/2" 5' - 7" 3' - 0" 5" 5" 2' - 10" 12' - 8" 12' - 8" 2' - 10"7 1/2" 7 1/2" 7 1/2" 5' - 7" 3' - 0" 5" 5" 2' - 10" 12' - 8" 12' - 8" 2' - 10" 4' - 2 1/8" 5' - 9 1/4" 6' - 3 7/8" 1' - 10 1/4" 4' - 0" 4' - 0" 4' - 0" 4' - 0" 1' - 10 1/4" 6' - 4 1/2" 5' - 9 1/4" 4' - 2 1/8" 7 1/2" 3' - 9 5/8" 9' - 10 1/8" 9' - 10 1/8" 3' - 9 5/8" 2' - 1" 4' - 0" 4' - 0" 2' - 1" 3' - 9 5/8" 9' - 10 1/8" 9' - 10 1/8" 3' - 9 5/8" 7 1/2" 11' - 7 3/4" 2' - 4 3/4" 6' - 0 1/4" 11' - 5 3/4" 8' - 0" 11' - 5 3/4" 6' - 3 3/4" 2' - 4 3/4" 11' - 4 1/4" 4' - 9 3/4" 8' - 11 1/4" 11' - 3 3/4" 6' - 0 1/4" 13' - 9" 6' - 10 1/8" 3' - 6 1/8" 1' - 7 5/8" 6' - 1 3/4" 5' - 11 1/8" 5" 2' - 0" 3' - 7 1/4" 6' - 10 1/8" 3' - 6 1/8" 1' - 10 5/8" 5' - 10 3/4" 5' - 11 1/8" 5" 2' - 0" 3' - 7 1/4" 14' - 0 1/2" 6' - 0 1/4" 11' - 0 1/4" 9' - 2 3/4" 4' - 9 3/4" 11' - 11 7/8" 11' - 11 3/8" 12' - 2 7/8" 11' - 11 3/8" A2.1 2 103 103A 103C 103D 103F 103G 103H 102 101 100 104 104A 104B 104C 104D 104H 104F 104G 104E 103E A A A A A ACCDDA A A OPEN AIR PORCH ENTRY PORCH 3' - 5" BB 2 A5.0 1 A5.0 4 A5.0 1 A5.1 2 A5.1 103B SEE COVER PAGE FOR NOTES AND LIMITATIONS TO ARCHITECTURAL SCOPE OF SERVICES. GENERAL CONTRACTOR NOTE: ADJUST TOP OF SLAB, WALL, AND ROOF BEARING PLATES AS REQUIRED FOR CHANGES IN STRUCTURAL MEMBER SIZES OR EXISTING SITE CONDITIONS. GC/OWNER TO COORDINATE ALL IN-SLAB ELECTRICAL AND PLUMBING REQUIREMENTS WITH APPROPRIATE SUBCONTRACTOR TRADES PRIOR TO PLACING SLAB. DIMENSION NOTES: DIMENSIONS ARE TO THE EDGE OF FOUNDATION AND FRAMING, U.O.N.. DO NOT SCALE DRAWINGS. CONTACT ARCHITECT WITH ANY DISCREPANCIES. CABINET & EQUIPMENT NOTES: CABINET LAYOUTS ARE PROVIDED FOR DESIGN CONFIGURATION ONLY. EXACT LAYOUT AND PLACEMENT OF FIXTURES, APPLIANCES, CABINETS, AND COUNTERTOPS ARE TO BE DETERMINED IN COORDINATION WITH OWNER AND GENERAL CONTRACTOR. FINISH NOTES: FLOOR, WALL, CEILING, FINISHES AND INTERIOR TRIM ARE TO BE DETERMINED BY THE GENERAL CONTRACTOR AND OWNER. GENERAL CONTRACTOR TO ADJUST SLAB, WALLS, AND CEILING TO ACCOMMODATE OWNER SPECIFIC FINISHES AND TRIM. OR FLOOR, WALL, CEILING, AND FINISHES ARE AS NOTED ON FINISH SCHEDULE - SEE SHEET A8.0. GENERAL CONTRACTOR TO ADJUST SLAB, WALLS, AND CEILING TO ACCOMMODATE OWNER SPECIFIC FINISHES AND TRIM. PLUMBING NOTES: G.C / OWNER TO COORDINATE LOCATION OF EXTERIOR HOSE BIBBS. FRAMING NOTES: STRUCTURAL ENGINEERING DOCUMENTS SUPERSEDE ARCHITECTURAL DOCUMENTS AND SCHEDULES WITH REGARD TO SIZE OF STRUCTURAL MEMBERS, PLACEMENT, AND CONNECTION DETAILS. DOOR OPENINGS SET 6" OFF INTERSECTING WALL, UNLESS OTHERWISE DIMENSIONED. UNLESS OTHERWISE NOTED BY TYPICAL WALL SECTIONS, STRUCTURAL ENGINEER, OR STRUCTURAL DRAWINGS. FRAMING IS TO BE AS FOLLOWS: WALLS: EXTERIOR: 1/2" PLYWOOD SHEATHING (EXTERIOR SIDE) ON 2x6'S AT 16" O.C. WITH BLOCKING AT MIDSPAN. INTERIOR: 2x4'S AND 2x6'S AT 16" O.C. WITH BLOCKING AT MIDSPAN. FIRST FLOOR SYSTEM: 3/4 " T&G PLYWOOD, GLUED AND NAILED ON 14" MANUFACTURED TRUSS JOIST SYSTEM AT 16" O.C. (OR SPECIFIED INTERVALS) SEE TYPICAL WALL SECTIONS AND DETAILS FOR VARIOUS CONNECTION DETAILS. NOTE: IF TRUSS JOISTS (OR SIM.) ARE USED IN LIEU OF SPECIFIED MATERIALS, TRUSS MANUFACTURER IS TO PROVIDE SHOP DRAWINGS, SUPPORT AND CONNECTION DETAILS, AND BEAM SIZES FOR ARCHITECT/ENGINEER APPROVAL. SECOND FLOOR SYSTEM: 3/4" T&G PLYWOOD, GLUED AND NAILED ON 14" OPEN WEB WOOD TRUSS SYSTEM (LAYOUT AND SPACING BY STRUCTURAL ENG). SEE TYPICAL WALL SECTIONS AND DETAILS FOR VARIOUS CONNECTION DETAILS, NOTE: IF TRUSS JOISTS (OR SIM.) ARE USED IN LIEU OF SPECIFIED MATERIALS, TRUSS MANUFACTURER IS TO PROVIDE SHOP DRAWINGS, SUPPORT AND CONNECTION DETAILS, AND BEAM SIZES FOR ARCHITECT/ENGINEER APPROVAL. PORCH FLOOR SYSTEM: 5/4" x 6" P.T. T&G WOOD DECKING (OR SYNTHETIC EQUIVALENT), GLUED AND NAILED ON 2X12 P.T. WOOD JOIST SYSTEM AT 16" O.C. (OR SPECIFIED INTERVALS) SEE TYPICAL WALL SECTIONS AND DETAILS FOR VARIOUS CONNECTION DETAILS. ATTIC FLOOR SYSTEM: (ONLY EXTENT TO BE DETERMINED BY G.C.) 3/4" T&G PLYWOOD, GLUED AND NAILED ON 2x12'S AT 16" O.C. SEE TYPICAL WALL SECTIONS AND DETAILS FOR VARIOUS CONNECTION DETAILS. NOTE: IF TRUSS JOISTS (OR SIM.) ARE USED IN LIEU OF SPECIFIED MATERIALS, TRUSS MANUFACTURER IS TO PROVIDE SHOP DRAWINGS, SUPPORT AND CONNECTION DETAILS, AND BEAM SIZES FOR ARCHITECT/ENGINEER APPROVAL. ATTIC CEILING JOISTS / PORCH CEILING: 2x8'S AT 16" O.C. (2x10'S FOR CERTAIN SPANS) ROOF RAFTERS: 1/2" EXT SHEATHING, NAILED ON 2x10'S WITH SIMPSON HURRICANE CLIPS AT 16" O.C. SEE TYPICAL WALL SECTIONS FOR VARIOUS CONNECTION DETAILS. IF PRE-ENGINEERED WOOD ROOF TRUSSES ARE INSTALLED IN LIEU OF SPECIFIED MATERIALS, TRUSS MANUFACTURER IS TO PROVIDE SHOP DRAWINGS, SUPPORT AND CONNECTION DETAILS, AND SIZES FOR ARCHITECT/ENGINEER APPROVAL. OR NOTE: SEE STRUCTURAL ENGINEERING DOCUMENTS FOR SIZE, LOCATION AND PLACEMENT OF ALL WORK DESCRIBED. ALL DIMENSIONS ARE TO EDGE OF SLAB, BLOCK, AND FRAMING AND ARE INDEPENDENT FROM ALL BRICK LEDGES U.N.O. G.C. TO COORDINATE SIZE AND LOCATIONS OF ADDITIONAL BRICK LEDGES WITH PLANS, ELEVATIONS, AND DETAILS. 10" 2 1/2" 5" 5" 1 3/4" 5 3/4" 3/4" 3" 5"5" 3/4"3" 2 1/2" 10" 5 3/4" 3 1/2" 4" CONCRETE SLAB KDAT WD. COLUMN BASE TRIM 1X10 KDAT WD. COLUMN TRIM 6X6 PT. WD. POST (SEE STRUCT.) 2X4 WD. BLOCKING 1 1/2" 5" 3 1/4" 1 1/2" 1X1 WD. PICKET 2X4 KDAT WD. TOP CAP 1X4 KDAT WD. MEMBERS (BELOW) I SSUE P ROJECT INFO S HEET TITLE D ate P roject No. COPYRIGHT 2019 COURT ATKINS GROUP - THIS DRAWING IS THE PROPERTY OF THE ARCHITECT AND IS NOT TO BE REPRODUCED IN WHOLE OR IN PART BY ANY MEANS OR METHOD WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ARCHITECT. ANY UNAUTHORIZED REPRODUCTION OR REUSE OF THESE DOCUMENTS WILL RESULT IN LEGAL ACTION. POST OFFICE BOX 3978 BLUFFTON, SC 29910 PH: 843.815.2557 FX: 843.815.2547 WWW.COURTATKINS.COM © 1/22/2021 4:30:25 PM 2 021.01.22 2 0-0 95 A2.1 O LD VILLAGE SQUARE - B UILDING 4 6 MARIANNA WAY B LUFFTON, SC 29910 F IRST FLOOR PLAN 1/4" = 1'-0"A2.1 1 FIRST FLOOR PLAN N O. REV. DATE DESCRIPTION 3/4" = 1'-0"A2.1 2 FIRST FLOOR - COLUMN DETAIL ATTACHMENT 4 DN UP Washer Dryer Range WasherDryer Range Refrigerator Refrigerator A3.11 A3.0 1 A3.2 1 A3.3 1 BEDROOM 1CLOSET 1 VESTIBULE 1 BATHROOM 1 LAUNDRY KITCHEN, LIVING & DINING VESTIBULE 2 BATHROOM 2 BEDROOM 2 CLOSET 2 KITCHEN, LIVING & DINING LAUNDRY BATHROOM 1VESTIBULE 1 BEDROOM 1 VESTIBULE 2 BATHROOM 2 BEDROOM 2 CLOSET 2 CLOSET 1 OPEN AIR PORCH COMMUNITY PORCH OPEN AIR PORCH 24' - 0" 8' - 0" 8' - 0" 8' - 0" 24' - 0" 7 1/4" 1' - 10" 9' - 5" 31' - 0" 5' - 0" 47' - 10 1/4" 72' - 0" 72' - 0" 5' - 0"31' - 0"9' - 5"1' - 10"7 1/4" 47' - 10 1/4" 4' - 2 1/8" 5' - 10 5/8" 1' - 10 1/8" 1' - 10 1/8" 5' - 10 5/8" 4' - 2 1/8" 2' - 10"12' - 8" 12' - 8"2' - 10"10"8' - 7"7 1/4" 2' - 0 1/4" 7 1/4" 7' - 7 1/4" 1' - 10" 8' - 5 1/4" 1' - 10" 6' - 11 7/8" 7 1/4" 1' - 10" 8' - 6" 1' - 10" 7 1/4" 6' - 11 7/8" 1' - 10" 8' - 5 1/4" 1' - 10" 7' - 7 1/4" 7 1/4" 2' - 0 1/4" 2' - 10"10"8' - 7"7 1/4" 12' - 8"12' - 8" 2' - 10" 3' - 9 5/8" 9' - 10 1/8" 9' - 10 1/8" 3' - 9 5/8" 2' - 1" 4' - 0" 4' - 0" 2' - 1" 3' - 9 5/8" 9' - 10 1/8" 9' - 10 1/8" 3' - 9 5/8" 11' - 7 3/4" 2' - 4 3/4" 6' - 0 1/4" 11' - 5 3/4" 8' - 0" 11' - 9 1/4" 6' - 0 1/4" 2' - 4 3/4" 11' - 4 1/4" 6' - 10 1/8" 5' - 4 3/4" 5' - 10 3/4" 5' - 11 1/8" 5" 2' - 0" 3' - 7 1/4" 14' - 0 1/2" 6' - 0 1/4" 11' - 0 1/4" 11' - 3 3/4" 6' - 0 1/4" 13' - 9" 3' - 7 1/4"2' - 0"5"5' - 11 1/8"5' - 10 3/4"5' - 4 3/4"6' - 10 1/8" 9' - 2 3/4" 4' - 9 3/4" 4' - 9 3/4" 8' - 11 1/4" LANDING STAIR LANDING A2.1 2 202E 201E 200 201 201A 201B 201C 201D 201H 201F 201G 202 202A 202B 202C 202D 202H 202F 202G E EEE E E E D D C C E E E BB 2 A5.0 1 A5.0 1 A5.1 2 A5.1 3 A5.1 SEE COVER PAGE FOR NOTES AND LIMITATIONS TO ARCHITECTURAL SCOPE OF SERVICES. GENERAL CONTRACTOR NOTE: ADJUST TOP OF SLAB, WALL, AND ROOF BEARING PLATES AS REQUIRED FOR CHANGES IN STRUCTURAL MEMBER SIZES OR EXISTING SITE CONDITIONS. GC/OWNER TO COORDINATE ALL IN-SLAB ELECTRICAL AND PLUMBING REQUIREMENTS WITH APPROPRIATE SUBCONTRACTOR TRADES PRIOR TO PLACING SLAB. DIMENSION NOTES: DIMENSIONS ARE TO THE EDGE OF FOUNDATION AND FRAMING, U.O.N.. DO NOT SCALE DRAWINGS. CONTACT ARCHITECT WITH ANY DISCREPANCIES. CABINET & EQUIPMENT NOTES: CABINET LAYOUTS ARE PROVIDED FOR DESIGN CONFIGURATION ONLY. EXACT LAYOUT AND PLACEMENT OF FIXTURES, APPLIANCES, CABINETS, AND COUNTERTOPS ARE TO BE DETERMINED IN COORDINATION WITH OWNER AND GENERAL CONTRACTOR. FINISH NOTES: FLOOR, WALL, CEILING, FINISHES AND INTERIOR TRIM ARE TO BE DETERMINED BY THE GENERAL CONTRACTOR AND OWNER. GENERAL CONTRACTOR TO ADJUST SLAB, WALLS, AND CEILING TO ACCOMMODATE OWNER SPECIFIC FINISHES AND TRIM. OR FLOOR, WALL, CEILING, AND FINISHES ARE AS NOTED ON FINISH SCHEDULE - SEE SHEET A8.0. GENERAL CONTRACTOR TO ADJUST SLAB, WALLS, AND CEILING TO ACCOMMODATE OWNER SPECIFIC FINISHES AND TRIM. PLUMBING NOTES: G.C / OWNER TO COORDINATE LOCATION OF EXTERIOR HOSE BIBBS. FRAMING NOTES: STRUCTURAL ENGINEERING DOCUMENTS SUPERSEDE ARCHITECTURAL DOCUMENTS AND SCHEDULES WITH REGARD TO SIZE OF STRUCTURAL MEMBERS, PLACEMENT, AND CONNECTION DETAILS. DOOR OPENINGS SET 6" OFF INTERSECTING WALL, UNLESS OTHERWISE DIMENSIONED. UNLESS OTHERWISE NOTED BY TYPICAL WALL SECTIONS, STRUCTURAL ENGINEER, OR STRUCTURAL DRAWINGS. FRAMING IS TO BE AS FOLLOWS: WALLS: EXTERIOR: 1/2" PLYWOOD SHEATHING (EXTERIOR SIDE) ON 2x6'S AT 16" O.C. WITH BLOCKING AT MIDSPAN. INTERIOR: 2x4'S AND 2x6'S AT 16" O.C. WITH BLOCKING AT MIDSPAN. FIRST FLOOR SYSTEM: 3/4 " T&G PLYWOOD, GLUED AND NAILED ON 14" MANUFACTURED TRUSS JOIST SYSTEM AT 16" O.C. (OR SPECIFIED INTERVALS) SEE TYPICAL WALL SECTIONS AND DETAILS FOR VARIOUS CONNECTION DETAILS. NOTE: IF TRUSS JOISTS (OR SIM.) ARE USED IN LIEU OF SPECIFIED MATERIALS, TRUSS MANUFACTURER IS TO PROVIDE SHOP DRAWINGS, SUPPORT AND CONNECTION DETAILS, AND BEAM SIZES FOR ARCHITECT/ENGINEER APPROVAL. SECOND FLOOR SYSTEM: 3/4" T&G PLYWOOD, GLUED AND NAILED ON 14" OPEN WEB WOOD TRUSS SYSTEM (LAYOUT AND SPACING BY STRUCTURAL ENG). SEE TYPICAL WALL SECTIONS AND DETAILS FOR VARIOUS CONNECTION DETAILS, NOTE: IF TRUSS JOISTS (OR SIM.) ARE USED IN LIEU OF SPECIFIED MATERIALS, TRUSS MANUFACTURER IS TO PROVIDE SHOP DRAWINGS, SUPPORT AND CONNECTION DETAILS, AND BEAM SIZES FOR ARCHITECT/ENGINEER APPROVAL. PORCH FLOOR SYSTEM: 5/4" x 6" P.T. T&G WOOD DECKING (OR SYNTHETIC EQUIVALENT), GLUED AND NAILED ON 2X12 P.T. WOOD JOIST SYSTEM AT 16" O.C. (OR SPECIFIED INTERVALS) SEE TYPICAL WALL SECTIONS AND DETAILS FOR VARIOUS CONNECTION DETAILS. ATTIC FLOOR SYSTEM: (ONLY EXTENT TO BE DETERMINED BY G.C.) 3/4" T&G PLYWOOD, GLUED AND NAILED ON 2x12'S AT 16" O.C. SEE TYPICAL WALL SECTIONS AND DETAILS FOR VARIOUS CONNECTION DETAILS. NOTE: IF TRUSS JOISTS (OR SIM.) ARE USED IN LIEU OF SPECIFIED MATERIALS, TRUSS MANUFACTURER IS TO PROVIDE SHOP DRAWINGS, SUPPORT AND CONNECTION DETAILS, AND BEAM SIZES FOR ARCHITECT/ENGINEER APPROVAL. ATTIC CEILING JOISTS / PORCH CEILING: 2x8'S AT 16" O.C. (2x10'S FOR CERTAIN SPANS) ROOF RAFTERS: 1/2" EXT SHEATHING, NAILED ON 2x10'S WITH SIMPSON HURRICANE CLIPS AT 16" O.C. SEE TYPICAL WALL SECTIONS FOR VARIOUS CONNECTION DETAILS. IF PRE-ENGINEERED WOOD ROOF TRUSSES ARE INSTALLED IN LIEU OF SPECIFIED MATERIALS, TRUSS MANUFACTURER IS TO PROVIDE SHOP DRAWINGS, SUPPORT AND CONNECTION DETAILS, AND SIZES FOR ARCHITECT/ENGINEER APPROVAL. OR NOTE: SEE STRUCTURAL ENGINEERING DOCUMENTS FOR SIZE, LOCATION AND PLACEMENT OF ALL WORK DESCRIBED. ALL DIMENSIONS ARE TO EDGE OF SLAB, BLOCK, AND FRAMING AND ARE INDEPENDENT FROM ALL BRICK LEDGES U.N.O. G.C. TO COORDINATE SIZE AND LOCATIONS OF ADDITIONAL BRICK LEDGES WITH PLANS, ELEVATIONS, AND DETAILS. I SSUE P ROJECT INFO S HEET TITLE D ate P roject No. COPYRIGHT 2019 COURT ATKINS GROUP - THIS DRAWING IS THE PROPERTY OF THE ARCHITECT AND IS NOT TO BE REPRODUCED IN WHOLE OR IN PART BY ANY MEANS OR METHOD WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ARCHITECT. ANY UNAUTHORIZED REPRODUCTION OR REUSE OF THESE DOCUMENTS WILL RESULT IN LEGAL ACTION. POST OFFICE BOX 3978 BLUFFTON, SC 29910 PH: 843.815.2557 FX: 843.815.2547 WWW.COURTATKINS.COM © 1/22/2021 4:30:28 PM 2 021.01.22 2 0-0 95 A2.2 O LD VILLAGE SQUARE - B UILDING 4 6 MARIANNA WAY B LUFFTON, SC 29910 S ECOND FLOOR P LAN 1/4" = 1'-0"A2.2 1 SECOND FLOOR N O. REV. DATE DESCRIPTION ATTACHMENT 4 DN Range WasherDryer Range Washer Dryer Refrigerator Refrigerator A3.11 A3.0 1 A3.2 1 A3.3 1 KITCHEN, DINING & LIVING BEDROOM 1 CLOSET 1 BATHROOM LAUNDRYLAUNDRY KITCHEN, DINING & LIVING CLOSET 1 BEDROOM 1 BATHROOMBALCONY BALCONY LANDING 31' - 0" 5' - 0" 5' - 0"31' - 0" 32' - 0" 8' - 0" 32' - 0" 82' - 0 1/4" CLOSET 2 BEDROOM 2 CLOSET 2 BEDROOM 2 9' - 11 1/2" 2' - 0 1/4" 2' - 10 3/8" 2' - 10 3/8" 2' - 10 3/8" 2' - 0 1/4" 9' - 5" 9' - 11 1/2"2' - 0 1/4"2' - 10 3/8"2' - 10 3/8"2' - 10 3/8"2' - 0 1/4"9' - 5" 8" 4' - 4 1/8" 32' - 0" 8' - 0" 32' - 0" 4' - 4 1/8" 8" 8' - 6 3/8" 2' - 0 1/4" 2' - 10 3/8" 2' - 10 3/8" 2' - 10 3/8" 2' - 0 1/4" 10' - 10 1/8" 4' - 0" 8' - 6 3/8"2' - 0 1/4"2' - 10 3/8"2' - 10 3/8"2' - 10 3/8"2' - 0 1/4"10' - 10 1/8" 36' - 0" 36' - 0" 8' - 6 3/8" 4' - 0 3/4" 7' - 11 1/4" 10' - 6 5/8" 9' - 11 1/2" 2' - 7" 5' - 4 1/4" 4' - 0 3/4" 5' - 9 3/4" 3' - 3 3/4" 3' - 0 1/4" 6' - 4 3/4" 4' - 0 3/4" 5' - 4 1/4" 2' - 3 1/2" 9' - 11 1/2" 20' - 6 3/8" 10' - 6 5/8" 7' - 10" 2' - 4 3/4" 7' - 2" 2' - 4 3/4" 3' - 0" 7' - 3 1/2" 3' - 1 3/4" 2' - 5 3/8" 12' - 6 1/8" 7' - 3 1/2" 7' - 10" 2' - 4 3/4" 7' - 2" 6' - 0 3/4" 6' - 7 1/2" 7' - 10" 2' - 4 3/4" 7' - 2" 2' - 4 3/4" 3' - 0" 7' - 3 1/2" 10' - 10 1/8" 20' - 2 7/8" 3' - 1 3/4" 2' - 4 3/4" 12' - 6 3/4" 7' - 3 1/2"10' - 10 1/8" 12' - 0" 8' - 2 7/8" 7' - 10" 2' - 4 3/4" 7' - 2" 6' - 0 3/4" 6' - 7 1/2" 301 301A 301B 301C 301D 301E 301F 301G 302 302A 302B302C 302E 302F 302G 302D F F F FFFFF F F F F H F F F F 1 A5.1 5' - 0 5/8" 7 1/4" 6' - 7" 3' - 3 1/2" 3' - 3 1/2" 6' - 7" 7 1/4" 4' - 11 7/8" 4' - 11 7/8"7 1/4"6' - 7"3' - 3 1/2"3' - 3 1/2"6' - 7"7 1/4"5' - 0 5/8" SEE COVER PAGE FOR NOTES AND LIMITATIONS TO ARCHITECTURAL SCOPE OF SERVICES. GENERAL CONTRACTOR NOTE: ADJUST TOP OF SLAB, WALL, AND ROOF BEARING PLATES AS REQUIRED FOR CHANGES IN STRUCTURAL MEMBER SIZES OR EXISTING SITE CONDITIONS. GC/OWNER TO COORDINATE ALL IN-SLAB ELECTRICAL AND PLUMBING REQUIREMENTS WITH APPROPRIATE SUBCONTRACTOR TRADES PRIOR TO PLACING SLAB. DIMENSION NOTES: DIMENSIONS ARE TO THE EDGE OF FOUNDATION AND FRAMING, U.O.N.. DO NOT SCALE DRAWINGS. CONTACT ARCHITECT WITH ANY DISCREPANCIES. CABINET & EQUIPMENT NOTES: CABINET LAYOUTS ARE PROVIDED FOR DESIGN CONFIGURATION ONLY. EXACT LAYOUT AND PLACEMENT OF FIXTURES, APPLIANCES, CABINETS, AND COUNTERTOPS ARE TO BE DETERMINED IN COORDINATION WITH OWNER AND GENERAL CONTRACTOR. FINISH NOTES: FLOOR, WALL, CEILING, FINISHES AND INTERIOR TRIM ARE TO BE DETERMINED BY THE GENERAL CONTRACTOR AND OWNER. GENERAL CONTRACTOR TO ADJUST SLAB, WALLS, AND CEILING TO ACCOMMODATE OWNER SPECIFIC FINISHES AND TRIM. OR FLOOR, WALL, CEILING, AND FINISHES ARE AS NOTED ON FINISH SCHEDULE - SEE SHEET A8.0. GENERAL CONTRACTOR TO ADJUST SLAB, WALLS, AND CEILING TO ACCOMMODATE OWNER SPECIFIC FINISHES AND TRIM. PLUMBING NOTES: G.C / OWNER TO COORDINATE LOCATION OF EXTERIOR HOSE BIBBS. FRAMING NOTES: STRUCTURAL ENGINEERING DOCUMENTS SUPERSEDE ARCHITECTURAL DOCUMENTS AND SCHEDULES WITH REGARD TO SIZE OF STRUCTURAL MEMBERS, PLACEMENT, AND CONNECTION DETAILS. DOOR OPENINGS SET 6" OFF INTERSECTING WALL, UNLESS OTHERWISE DIMENSIONED. UNLESS OTHERWISE NOTED BY TYPICAL WALL SECTIONS, STRUCTURAL ENGINEER, OR STRUCTURAL DRAWINGS. FRAMING IS TO BE AS FOLLOWS: WALLS: EXTERIOR: 1/2" PLYWOOD SHEATHING (EXTERIOR SIDE) ON 2x6'S AT 16" O.C. WITH BLOCKING AT MIDSPAN. INTERIOR: 2x4'S AND 2x6'S AT 16" O.C. WITH BLOCKING AT MIDSPAN. FIRST FLOOR SYSTEM: 3/4 " T&G PLYWOOD, GLUED AND NAILED ON 14" MANUFACTURED TRUSS JOIST SYSTEM AT 16" O.C. (OR SPECIFIED INTERVALS) SEE TYPICAL WALL SECTIONS AND DETAILS FOR VARIOUS CONNECTION DETAILS. NOTE: IF TRUSS JOISTS (OR SIM.) ARE USED IN LIEU OF SPECIFIED MATERIALS, TRUSS MANUFACTURER IS TO PROVIDE SHOP DRAWINGS, SUPPORT AND CONNECTION DETAILS, AND BEAM SIZES FOR ARCHITECT/ENGINEER APPROVAL. SECOND FLOOR SYSTEM: 3/4" T&G PLYWOOD, GLUED AND NAILED ON 14" OPEN WEB WOOD TRUSS SYSTEM (LAYOUT AND SPACING BY STRUCTURAL ENG). SEE TYPICAL WALL SECTIONS AND DETAILS FOR VARIOUS CONNECTION DETAILS, NOTE: IF TRUSS JOISTS (OR SIM.) ARE USED IN LIEU OF SPECIFIED MATERIALS, TRUSS MANUFACTURER IS TO PROVIDE SHOP DRAWINGS, SUPPORT AND CONNECTION DETAILS, AND BEAM SIZES FOR ARCHITECT/ENGINEER APPROVAL. PORCH FLOOR SYSTEM: 5/4" x 6" P.T. T&G WOOD DECKING (OR SYNTHETIC EQUIVALENT), GLUED AND NAILED ON 2X12 P.T. WOOD JOIST SYSTEM AT 16" O.C. (OR SPECIFIED INTERVALS) SEE TYPICAL WALL SECTIONS AND DETAILS FOR VARIOUS CONNECTION DETAILS. ATTIC FLOOR SYSTEM: (ONLY EXTENT TO BE DETERMINED BY G.C.) 3/4" T&G PLYWOOD, GLUED AND NAILED ON 2x12'S AT 16" O.C. SEE TYPICAL WALL SECTIONS AND DETAILS FOR VARIOUS CONNECTION DETAILS. NOTE: IF TRUSS JOISTS (OR SIM.) ARE USED IN LIEU OF SPECIFIED MATERIALS, TRUSS MANUFACTURER IS TO PROVIDE SHOP DRAWINGS, SUPPORT AND CONNECTION DETAILS, AND BEAM SIZES FOR ARCHITECT/ENGINEER APPROVAL. ATTIC CEILING JOISTS / PORCH CEILING: 2x8'S AT 16" O.C. (2x10'S FOR CERTAIN SPANS) ROOF RAFTERS: 1/2" EXT SHEATHING, NAILED ON 2x10'S WITH SIMPSON HURRICANE CLIPS AT 16" O.C. SEE TYPICAL WALL SECTIONS FOR VARIOUS CONNECTION DETAILS. IF PRE-ENGINEERED WOOD ROOF TRUSSES ARE INSTALLED IN LIEU OF SPECIFIED MATERIALS, TRUSS MANUFACTURER IS TO PROVIDE SHOP DRAWINGS, SUPPORT AND CONNECTION DETAILS, AND SIZES FOR ARCHITECT/ENGINEER APPROVAL. OR NOTE: SEE STRUCTURAL ENGINEERING DOCUMENTS FOR SIZE, LOCATION AND PLACEMENT OF ALL WORK DESCRIBED. ALL DIMENSIONS ARE TO EDGE OF SLAB, BLOCK, AND FRAMING AND ARE INDEPENDENT FROM ALL BRICK LEDGES U.N.O. G.C. TO COORDINATE SIZE AND LOCATIONS OF ADDITIONAL BRICK LEDGES WITH PLANS, ELEVATIONS, AND DETAILS. I SSUE P ROJECT INFO S HEET TITLE D ate P roject No. COPYRIGHT 2019 COURT ATKINS GROUP - THIS DRAWING IS THE PROPERTY OF THE ARCHITECT AND IS NOT TO BE REPRODUCED IN WHOLE OR IN PART BY ANY MEANS OR METHOD WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ARCHITECT. ANY UNAUTHORIZED REPRODUCTION OR REUSE OF THESE DOCUMENTS WILL RESULT IN LEGAL ACTION. POST OFFICE BOX 3978 BLUFFTON, SC 29910 PH: 843.815.2557 FX: 843.815.2547 WWW.COURTATKINS.COM © 1/22/2021 4:30:30 PM 2 021.01.22 2 0-0 95 A2.3 O LD VILLAGE SQUARE - B UILDING 4 6 MARIANNA WAY B LUFFTON, SC 29910 L OFT LEVEL PLAN 1/4" = 1'-0"A2.3 1 LOFT FLR. HT. N O. REV. DATE DESCRIPTION ATTACHMENT 4 SEE COVER PAGE FOR NOTES AND LIMITATIONS TO ARCHITE CTURAL SCOPE OF SERVICES. GENERAL CONTRACTOR NOTE: ADJUST TOP OF SLAB, WALL, AND ROOF BEARING PLATES AS REQUIRED FOR CHANGES IN STRUCTURAL MEMBER SIZES OR EXISTING SITE CONDITIONS. GC/OWNER TO COORDINATE ALL IN-SLAB ELECTRICAL AND PLUMBING REQUIREMENTS WITH APPROPRIATE SUBCONTRACTOR TRADES PRIOR TO PLACING SLAB. DIMENSION NOTES: DIMENSIONS ARE TO THE EDGE OF FOUNDATION AND FRAMING, U.O.N.. DO NOT SCALE DRAWINGS. CONTACT ARCHITECT WITH ANY DISCREPANCIES. CABINET & EQUIPMENT NOTES: CABINET LAYOUTS ARE PROVIDED FOR DESIGN CONFIGURATION ONLY. EXACT LAYOUT AND PLACEMENT OF FIXTURES, APPLIANCES, CABINETS, AND COUNTERTOPS ARE TO BE DETERMINED IN COORDINATION WITH OWNER AND GENERAL CONTRACTOR. FINISH NOTES: FLOOR, WALL, CEILING, FINISHES AND INTERIOR TRIM ARE TO BE DETERMINED BY THE GENERAL CONTRACTOR AND OWNER. GENERAL CONTRACTOR TO ADJUST SLAB, WALLS, AND CEILING TO ACCOMMODATE OWNER SPECIFIC FINISHES AND TRIM. OR FLOOR, WALL, CEILING, AND FINISHES ARE AS NOTED ON FINISH SCHEDULE - SEE SHEET A8.0. GENERAL CONTRACTOR TO ADJUST SLAB, WALLS, AND CEILING TO ACCOMMODATE OWNER SPECIFIC FINISHES AND TRIM. PLUMBING NOTES: G.C / OWNER TO COORDINATE LOCATION OF EXTERIOR HOSE BIBBS. FRAMING NOTES: STRUCTURAL ENGINEERING DOCUMENTS SUPERSEDE ARCHITECTURAL DOCUMENTS AND SCHEDULES WITH REGARD TO SIZE OF STRUCTURAL MEMBERS, PLACEMENT, AND CONNECTION DETAILS. DOOR OPENINGS SET 6" OFF INTERSECTING WALL, UNLESS OTHERWISE DIMENSIONED. UNLESS OTHERWISE NOTED BY TYPICAL WALL SECTIONS, STRUCTURAL ENGINEER, OR STRUCTURAL DRAWINGS. FRAMING IS TO BE AS FOLLOWS: WALLS: EXTERIOR: 1/2" PLYWOOD SHEATHING (EXTERIOR SIDE) ON 2x6'S AT 16" O.C. WITH BLOCKING AT MIDSPAN. INTERIOR: 2x4'S AND 2x6'S AT 16" O.C. WITH BLOCKING AT MIDSPAN. FIRST FLOOR SYSTEM: 3/4 " T&G PLYWOOD, GLUED AND NAILED ON 14" MANUFACTURED TRUSS JOIST SYSTEM AT 16" O.C. (OR SPECIFIED INTERVALS) SEE TYPICAL WALL SECTIONS AND DETAILS FOR VARIOUS CONNECTION DETAILS. NOTE: IF TRUSS JOISTS (OR SIM.) ARE USED IN LIEU OF SPECIFIED MATERIALS, TRUSS MANUFACTURER IS TO PROVIDE SHOP DRAWINGS, SUPPORT AND CONNECTION DETAILS, AND BEAM SIZES FOR ARCHITECT/ENGINEER APPROVAL. SECOND FLOOR SYSTEM: 3/4" T&G PLYWOOD, GLUED AND NAILED ON 14" OPEN WEB WOOD TRUSS SYSTEM (LAYOUT AND SPACING BY STRUCTURAL ENG). SEE TYPICAL WALL SECTIONS AND DETAILS FOR VARIOUS CONNECTION DETAILS, NOTE: IF TRUSS JOISTS (OR SIM.) ARE USED IN LIEU OF SPECIFIED MATERIALS, TRUSS MANUFACTURER IS TO PROVIDE SHOP DRAWINGS, SUPPORT AND CONNECTION DETAILS, AND BEAM SIZES FOR ARCHITECT/ENGINEER APPROVAL. PORCH FLOOR SYSTEM: 5/4" x 6" P.T. T&G WOOD DECKING (OR SYNTHETIC EQUIVALENT), GLUED AND NAILED ON 2X12 P.T. WOOD JOIST SYSTEM AT 16" O.C. (OR SPECIFIED INTERVALS) SEE TYPICAL WALL SECTIONS AND DETAILS FOR VARIOUS CONNECTION DETAILS. ATTIC FLOOR SYSTEM: (ONLY EXTENT TO BE DETERMINED BY G.C.) 3/4" T&G PLYWOOD, GLUED AND NAILED ON 2x12'S AT 16" O.C. SEE TYPICAL WALL SECTIONS AND DETAILS FOR VARIOUS CONNECTION DETAILS. NOTE: IF TRUSS JOISTS (OR SIM.) ARE USED IN LIEU OF SPECIFIED MATERIALS, TRUSS MANUFACTURER IS TO PROVIDE SHOP DRAWINGS, SUPPORT AND CONNECTION DETAILS, AND BEAM SIZES FOR ARCHITECT/ENGINEER APPROVAL. ATTIC CEILING JOISTS / PORCH CEILING: 2x8'S AT 16" O.C. (2x10'S FOR CERTAIN SPANS) ROOF RAFTERS: 1/2" EXT SHEATHING, NAILED ON 2x10'S WITH SIMPSON HURRICANE CLIPS AT 16" O.C. SEE TYPICAL WALL SECTIONS FOR VARIOUS CONNECTION DETAILS. IF PRE-ENGINEERED WOOD ROOF TRUSSES ARE INSTALLED IN LIEU OF SPECIFIED MATERIALS, TRUSS MANUFACTURER IS TO PROVIDE SHOP DRAWINGS, SUPPORT AND CONNECTION DETAILS, AND SIZES FOR ARCHITECT/ENGINEER APPROVAL. OR NOTE: SEE STRUCTURAL ENGINEERING DOCUMENTS FOR SIZE, LOCATION AND PLACEMENT OF ALL WORK DESCRIBED. ALL DIMENSIONS ARE TO EDGE OF SLAB, BLOCK, AND FRAMING AND ARE INDEPENDENT FROM ALL BRICK LEDGES U.N.O. G.C. TO COORDINATE SIZE AND LOCATIONS OF ADDITIONAL BRICK LEDGES WITH PLANS, ELEVATIONS, AND DETAILS. A3.11 A3.0 1 A3.2 1 A3.3 1 2'-2" OVERHANG 1'-9" OVERHANG 1'-2" OVERHANG 1'-2" OVERHANG 1'-9" OVERHANG 2'-2" OVERHANG2'-2" OVERHANG7' - 1 3/4"1'-7" OVERHANG1'-1" OVERHANG8" OVERHANG8" OVERHANG1'-10" OVERHANG1'-10" OVERHANG 1'-7" OVERHANG 1'-1" OVERHANG 1'-7" OVERHANG 2'-2" OVERHANG7' - 1 5/8"1'-7" OVERHANG 8" OVERHANG8" OVERHANG 1'-7" OVERHANG 1'-6" OVERHANG 1'-7" OVERHANG 8" OVERHANG 8" OVERHANG 8" OVERHANG 8" OVERHANG 8/12 8/12 8/12 8/12 8/12 8/12 8/12 8/12 10/12 10/12 10/1210/12 10/12 10/12 10/12 3/12 3/12 3/12 3/12 3/12 3/12 3/123/12 1'-2" OVERHANG1'-2" OVERHANG 1'-2" OVERHANG 1'-2" OVERHANG 3 A5.1 I SSUE P ROJECT INFO S HEET TITLE D ate P roject No. COPYRIGHT 2019 COURT ATKINS GROUP - THIS DRAWING IS THE PROPERTY OF THE ARCHITECT AND IS NOT TO BE REPRODUCED IN WHOLE OR IN PART BY ANY MEANS OR METHOD WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ARCHITECT. ANY UNAUTHORIZED REPRODUCTION OR REUSE OF THESE DOCUMENTS WILL RESULT IN LEGAL ACTION. POST OFFICE BOX 3978 BLUFFTON, SC 29910 PH: 843.815.2557 FX: 843.815.2547 WWW.COURTATKINS.COM © 1/22/2021 4:30:32 PM 2 021.01.22 2 0-0 95 A2.4 O LD VILLAGE SQUARE - B UILDING 4 6 MARIANNA WAY B LUFFTON, SC 29910 R OOF PLAN 1/4" = 1'-0"A2.4 1 ROOF PLAN N O. REV. DATE DESCRIPTION ATTACHMENT 4 FIRST FLOOR HT. PORCH HT. SECOND FLOOR B.O. BEAM LOFT FLR. HT. DORMER BRG. 4' - 10 1/4"1' - 10"2' - 9 1/2"5' - 2 1/2"1' - 9"9' - 0"12' - 0"3" 6' - 2"37' - 8 1/4" EEEE A A A A FFFFFFFF G G G 8 12 8 12 8 12 8 12 104A 100 103A 202A 200 201A 2X KDAT WD TRIM (CHAMFER TO DRAIN)ON 1X4 CEMEN. TRIM OVER 1X6 CEMEN. TRIM 1X6 CEMEN. CORNER BD. 10X10 KDAT WD. COLUMN KDAT WD. COLUMN CAP KDAT WD. COLUMN BASE 2X KDAT WD TRIM (CHAMFER TO DRAIN)ON 1X4 CEMEN. TRIM ON 1X6 CEMEN. TRIM OVER 1X10 CEMEN. TRIM ALUM. CLAD / WD. DOUBLE -HUNG WINDOW KDAT WD. SHUTTER CEMENTITIOUS HORIZ. SIDING W/ 7" EXPOSURE 2X KDAT WD TRIM (CHAMFER TO DRAIN)ON 1X4 CEMEN. TRIM ON 1X6 CEMEN. TRIM OVER 1X10 CEMEN. TRIM KDAT WD. BALUSTER KDAT WD. CAP KDAT WD. BASE ASPHALT SHINGLES 1X10 CEMEN. CORNER BD. 1X4 CEMEN. TRIM ON 1X6 CEMEN.TRIM FASCIA STANDING SEAM METAL ROOF ALUM. CLAD. / WD. DOUBLE -HUNG WINDOW 1X CEMEN. TRIM BD. 2X KDAT WD. TRIM (CHAMFER TO DRAIN) ON 1X4 CEMEN. TRIM OVER 1X6 CEMEN. TRIM ALUM. CLAD / WD. FIXED WINDOW 1X4 CEMEN. TRIM ON 1X6 CEMEN. TRIM FASCIA STANDING SEAM METAL ROOF KDAT WD. TOP RAILKDAT WD. BOTTOM RAILALUM. CLAD. / WD. PATIO DOORINSWING IRON GATES W/ TRANSOMALUM. CLAD. / WD. PATIO DOOR CEMEN. HORIZ. SIDING W/ 7" EXPOSUREALUM. CLAD / WD. DOUBLE-HUNG WINDOW 2X KDAT WD TRIM (CHAMFER TO DRAIN)ON 1X4 CEMEN. TRIM OVER 1X6 CEMEN. TRIM 1X6 CEMEN. CORNER BD. 10X10 KDAT WD. COLUMN KDAT WD. COLUMN CAP KDAT WD. COLUMN BASE 2X KDAT WD TRIM (CHAMFER TO DRAIN)ON 1X4 CEMEN. TRIM ON 1X6 CEMEN. TRIM OVER 1X10 CEMEN. TRIM STANDING SEAM METAL ROOF HORIZ. CEMEN. SIDING W/ 7" EXPOSURE INSWING IRON GATES 1X8 CEMEN. CORNER BD. PORCH RF. RIDGE REAR RF. RIDGE MAIN RF. RIDGE COUPOLA RIDGE 1 A5.0 2 A5.0 I SSUE P ROJECT INFO S HEET TITLE D ate P roject No. COPYRIGHT 2019 COURT ATKINS GROUP - THIS DRAWING IS THE PROPERTY OF THE ARCHITECT AND IS NOT TO BE REPRODUCED IN WHOLE OR IN PART BY ANY MEANS OR METHOD WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ARCHITECT. ANY UNAUTHORIZED REPRODUCTION OR REUSE OF THESE DOCUMENTS WILL RESULT IN LEGAL ACTION. POST OFFICE BOX 3978 BLUFFTON, SC 29910 PH: 843.815.2557 FX: 843.815.2547 WWW.COURTATKINS.COM © 1/22/2021 4:30:44 PM 2 021.01.22 2 0-0 95 A3.0 O LD VILLAGE SQUARE - B UILDING 4 6 MARIANNA WAY B LUFFTON, SC 29910 F RONT EXTERIOR E LEVATION 1/4" = 1'-0"A3.0 1 FRONT EXTERIOR ELEVATION N O. REV. DATE DESCRIPTION ATTACHMENT 4 FIRST FLOOR HT. PORCH HT. SECOND FLOOR B.O. BEAM LOFT FLR. HT. DORMER BRG. 4' - 10 1/4"1' - 10"2' - 9 1/2"5' - 2 1/2"1' - 9"9' - 0"12' - 0"3" 6' - 2"37' - 8 1/4" G EE A 8 12 10 12 10 12 8 12 3 12 3 12 3 12 301D 8 12 10 12 10 12 8 12 3 12 3 12 3 12 1X6 CEMEN. CORNER BD. KDAT WD. COLUMN BASE 2X KDAT WD TRIM (CHAMFER TO DRAIN)ON 1X4 CEMEN. TRIM ON 1X6 CEMEN. TRIM OVER 1X10 CEMEN. TRIM ALUM. CLAD / WD. DOUBLE -HUNG WINDOW CEMENTITIOUS HORIZ. SIDING W/ 7" EXPOSURE KDAT WD. BALUSTER KDAT WD. CAP ASPHALT SHINGLES 1X4 CEMEN. TRIM ON 1X6 CEMEN.TRIM FASCIA ALUM. CLAD. / WD. PATIO DR. KDAT WD. BASE 1X6 CEMEN. CORNER BD. 10X10 KDAT WD. COLUMN KDAT WD. COLUMN CAP KDAT WD. COLUMN BASE 2X KDAT WD TRIM (CHAMFER TO DRAIN)ON 1X4 CEMEN. TRIM ON 1X6 CEMEN. TRIM OVER 1X10 CEMEN. TRIM KDAT WD. BOTTOM RAIL 1X1 PT. WD. PICKETS KDAT WD. TOP RAIL ALUM. CLAD / WD. DOUBLE -HUNG WINDOW CEMENTITIOUS HORIZ. SIDING W/ 7" EXPOSURE 1X10 CEMEN. CORNER BOARD 1X4 CEMEN. TRIM ON 1X6 CEMEN.TRIM FASCIA STANDING SEAM METAL ROOF 2X KDAT WD. TRIM (CHAMFER TO DRAIN) ON 1X4 CEMEN. TRIM OVER 1X6 CEMEN. TRIM ALUM. CLAD / WD. FIXED WINDOW 1X4 CEMEN. TRIM ON 1X6 CEMENT TRIM FASCIA STANDING SEAM METAL ROOF KDAT WD. TOP RAIL KDAT WD. BOTTOM RAIL CEMEN. HORIZ. SIDING W/ 7" EXPOSURE ALUM. CLAD / WD. PICTURE WINDOW PORCH RF. RIDGE REAR RF. RIDGE MAIN RF. RIDGE COUPOLA RIDGE 3 A5.1 I SSUE P ROJECT INFO S HEET TITLE D ate P roject No. COPYRIGHT 2019 COURT ATKINS GROUP - THIS DRAWING IS THE PROPERTY OF THE ARCHITECT AND IS NOT TO BE REPRODUCED IN WHOLE OR IN PART BY ANY MEANS OR METHOD WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ARCHITECT. ANY UNAUTHORIZED REPRODUCTION OR REUSE OF THESE DOCUMENTS WILL RESULT IN LEGAL ACTION. POST OFFICE BOX 3978 BLUFFTON, SC 29910 PH: 843.815.2557 FX: 843.815.2547 WWW.COURTATKINS.COM © 1/22/2021 4:30:55 PM 2 021.01.22 2 0-0 95 A3.1 O LD VILLAGE SQUARE - B UILDING 4 6 MARIANNA WAY B LUFFTON, SC 29910 R IGHT SIDE E XTERIOR E LEVATION 1/4" = 1'-0"A3.1 1 RIGHT SIDE EXTERIOR ELEVATION N O. REV. DATE DESCRIPTION ATTACHMENT 4 FIRST FLOOR HT. PORCH HT. SECOND FLOOR B.O. BEAM LOFT FLR. HT. DORMER BRG. 3" 12' - 0" 9' - 0" 1' - 9" 8' - 0" 1' - 10" 4' - 10 1/4" 37' - 8 1/4" 6' - 2" H FFFFFFFF CC E D D E A C C D D A 8 12 8 12 8 12 8 12 102 101 A6.0 1 8 12 8 12 2X KDAT WD TRIM (CHAMFER TO DRAIN)ON 1X4 CEMEN. TRIM OVER 1X6 CEMEN. TRIM 1X6 CEMEN. CORNER BD. KDAT WD. COLUMN BASE 2X KDAT WD TRIM (CHAMFER TO DRAIN)ON 1X4 CEMEN. TRIM ON 1X6 CEMEN. TRIM OVER 1X10 CEMEN. TRIM ALUM. CLAD / WD. DOUBLE -HUNG WINDOW KDAT WD. SHUTTER CEMENTITIOUS HORIZ. SIDING W/ 7" EXPOSURE 2X KDAT WD TRIM (CHAMFER TO DRAIN)ON 1X4 CEMEN. TRIM ON 1X6 CEMEN. TRIM OVER 1X10 CEMEN. TRIM KDAT WD. BALUSTER KDAT WD. CAP KDAT WD. BASE ASPHALT SHINGLES 1X10 CEMEN. CORNER BOARD 1X4 CEMEN. TRIM ON 1X6 CEMEN.TRIM FASCIA STANDING SEAM METAL ROOF ALUM. CLAD. / WD. DOUBLE -HUNG WINDOW 1X CEMEN. TRIM BD. 2X KDAT WD. TRIM (CHAMFER TO DRAIN) ON 1X4 CEMEN. TRIM OVER 1X6 CEMEN. TRIM ALUM. CLAD / WD. FIXED WINDOW 1X4 CEMEN. TRIM ON 1X6 CEMENT TRIM FASCIA STANDING SEAM METAL ROOF HORIZ. KDAT WD. SLATS @ SERVICE YARD KDAT WD. GUARDRAIL HORIZ. KDAT WD. SLATS @ SERVICE YARDCEMEN. HORIZ. SIDING W/ 7" EXPOSURE ALUM. CLAD / WD. DOUBLE-HUNG WINDOW 2X KDAT WD TRIM (CHAMFER TO DRAIN)ON 1X4 CEMEN. TRIM OVER 1X6 CEMEN. TRIM 1X6 CEMEN. CORNER BD. KDAT WD. COLUMN BASE 2X KDAT WD TRIM (CHAMFER TO DRAIN)ON 1X4 CEMEN. TRIM ON 1X6 CEMEN. TRIM OVER 1X10 CEMEN. TRIM ASPHALT SHINGLES HORIZ. CEMEN. SIDING W/ 7" EXPOSURE KDAT WD. FRAME 1X8 CEMEN. CORNER BD. STANDING SEAM METAL ROOF KDAT WD. SHUTTER REAR RF. RIDGE MAIN RF. RIDGE COUPOLA RIDGE 4 A5.0 I SSUE P ROJECT INFO S HEET TITLE D ate P roject No. COPYRIGHT 2019 COURT ATKINS GROUP - THIS DRAWING IS THE PROPERTY OF THE ARCHITECT AND IS NOT TO BE REPRODUCED IN WHOLE OR IN PART BY ANY MEANS OR METHOD WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ARCHITECT. ANY UNAUTHORIZED REPRODUCTION OR REUSE OF THESE DOCUMENTS WILL RESULT IN LEGAL ACTION. POST OFFICE BOX 3978 BLUFFTON, SC 29910 PH: 843.815.2557 FX: 843.815.2547 WWW.COURTATKINS.COM © 1/22/2021 4:31:08 PM 2 021.01.22 2 0-0 95 A3.2 O LD VILLAGE SQUARE - B UILDING 4 6 MARIANNA WAY B LUFFTON, SC 29910 R EAR EXTERIOR E LEVATION 1/4" = 1'-0"A3.2 1 REAR EXTERIOR ELEVATION N O. REV. DATE DESCRIPTION ATTACHMENT 4 FIRST FLOOR HT. PORCH HT. SECOND FLOOR B.O. BEAM LOFT FLR. HT. DORMER BRG. 4' - 10 1/4"1' - 10"2' - 9 1/2"5' - 2 1/2"1' - 9"9' - 0"12' - 0"3" 6' - 2"37' - 8 1/4" EE A A G 8 12 10 12 10 12 8 12 3 12 3 12 3 12 302D 1X6 CEMEN. CORNER BD. KDAT WD. COLUMN BASE 2X KDAT WD TRIM (CHAMFER TO DRAIN)ON 1X4 KCEMEN. TRIM ON 1X6 CEMEN. TRIM OVER 1X10 CEMEN. TRIM ALUM. CLAD / WD. DOUBLE -HUNG WINDOW CEMENTITIOUS HORIZ. SIDING W/ 7" EXPOSURE KDAT WD. BALUSTER KDAT WD. CAP ASPHALT SHINGLES 1X4 CEMEN. TRIM ON 1X6 CEMEN.TRIM FASCIA ALUM. CLAD. / WD. PATIO DOOR KDAT WD. BASE 1X6 CEMEN. CORNER BD. 10X10 KDAT WD. COLUMN KDAT WD. COLUMN CAP KDAT WD. COLUMN BASE 2X KDAT WD TRIM (CHAMFER TO DRAIN)ON 1X4 CEMEN. TRIM ON 1X6 CEMEN. TRIM OVER 1X10 CEMEN. TRIM KDAT WD. BOTTOM RAIL 1X1 PT. WD. PICKETS KDAT WD. TOP RAIL ALUM. CLAD / WD. DOUBLE -HUNG WINDOW CEMENTITIOUS HORIZ. SIDING W/ 7" EXPOSURE 1X10 CEMEN. CORNER BOARD 1X4 CEMEN. TRIM ON 1X6 CEMEN.TRIM FASCIA STANDING SEAM METAL ROOF 2X KDAT WD. TRIM (CHAMFER TO DRAIN) ON 1X4 CEMEN. TRIM OVER 1X6 CEMEN. TRIM ALUM. CLAD / WD. FIXED WINDOW 1X4 CEMEN. TRIM ON 1X6 CEMENT TRIM FASCIA STANDING SEAM METAL ROOF KDAT WD. TOP RAILKDAT WD. BOTTOM RAILCEMEN. HORIZ. SIDING W/ 7" EXPOSURE ALUM. CLAD / WD. PICTURE WINDOW PORCH RF. RIDGE REAR RF. RIDGE MAIN RF. RIDGE COUPOLA RIDGE 3 A5.1 I SSUE P ROJECT INFO S HEET TITLE D ate P roject No. COPYRIGHT 2019 COURT ATKINS GROUP - THIS DRAWING IS THE PROPERTY OF THE ARCHITECT AND IS NOT TO BE REPRODUCED IN WHOLE OR IN PART BY ANY MEANS OR METHOD WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ARCHITECT. ANY UNAUTHORIZED REPRODUCTION OR REUSE OF THESE DOCUMENTS WILL RESULT IN LEGAL ACTION. POST OFFICE BOX 3978 BLUFFTON, SC 29910 PH: 843.815.2557 FX: 843.815.2547 WWW.COURTATKINS.COM © 1/22/2021 4:31:18 PM 2 021.01.22 2 0-0 95 A3.3 O LD VILLAGE SQUARE - B UILDING 4 6 MARIANNA WAY B LUFFTON, SC 29910 L EFT SIDE EXTERIOR E LEVATION 1/4" = 1'-0"A3.3 1 LEFT SIDE EXTERIOR ELEVATION N O. REV. DATE DESCRIPTION ATTACHMENT 4 B .O. BEAM T .O. GUARDRAIL T .O. GUARDRAIL DOOR HEAD HT. ROOF BEARING ROOF BEARING DOOR HEAD HT. B.O. BEAM ROOF BEARING WIN. HD. HT. WIN. SILL HT. T.O. BEAM T.O. SERVICE YARD F IRST FLOOR HT. P ORCH HT. SECOND FLOOR B .O. BEAM L OFT FLR. HT. PORCH RF. RIDGE 1 ' - 9"5 ' - 2 7/8"3 ' - 9 1/8"1 ' - 9"6 ' - 8 7/8"3 ' - 6 1/8"3 " STANDING SEAM METAL ROOF APA RATED PLYWD. SHEATHING PRE-FIN. MTL. DRIP EDGE 2X WD. BLOCKING (CONT.) KDAT WD. COVE MOLDING 2X WD. BLOKCKING (CONT.) 1X6 CEMEN. TRIM 2X WD. BLOCKING (CONT.) 3/8" CEMEN. SOFFIT BD. 1X2 CEMEN. TRIM @ GABLE 2X8 KDAT WD. TRIM @ GABLE PRE-FIN. MTL. FLASHING HORIZ. CEMEN. SIDING W/ 7" EXP. 5/8" APA RATED PLYWD. SHEATHING (1) LAYER COMMERCIAL BLDG. WRAP STANDING SEAM METAL ROOF PRE-FIN. MTL. FLASHING 2X WD. BLOCKING 5/8" APA RATED PLYWD. SHEATHING PRE-FIN. MTL. FLASHING KDAT WD. COVE MOLDING 1X10 CEMEN. TRIM WD. WD. BLOCKING KDAT WD. COVE 1X8 CEMEN. TRIM 1X WD. BLOCKING 3/8" CEMEN. SOFFIT BD. 5 ' - 2 1/2" KDAT WD. COLUMN CAPITAL TRIM KDAT WD. T&G CEILING 10X10 ENGINEERED WD. COLUMN 2X4 PT. WD. GUARDRTAIL CAP (CHAMFER TO DRAIN) 1X3 PT. WD. HORIZ. RAIL MEMBER 1X1 PT. WD. PICKETS 1X3 PT. WD. HORIZ. RAIL MEMBER 1X4 PT. WD. BOTTOM RAIL 1X6 PT. WD. DECK BOARDS 2X WD. SLEEPER (@ SLOPE 1/8" / FT.) 2X KDAT WD. TRIM (CHAMFER TO DRAIN) KDAT WD. COLUMN BASE TRIM 1X4 CEMEN. TRIM ON 1X10 CEMEN. TRIM EXTEND TPO MEMBRANE OVER EDGE ONTO TPO COATED MTL. FLASHING 1X4 WD. BLOCKING 5/8" APA RATED PLYWD. SHEATHING WD. BEAM (SEE STRUCT.) 1X12 CEMEN. TRIM 2X WD. FRAMING 1X CEMEN. TRIM 10X10 ENGINEERED WD. COLUMN KDAT WD. T&G CEILING 2X4 PT. WD. GUARDRTAIL CAP (CHAMFER TO DRAIN) 1X3 PT. WD. HORIZ. RAIL MEMBER 1X1 PT. WD. PICKETS 1X3 PT. WD. HORIZ. RAIL MEMBER 1X4 PT. WD. BOTTOM RAIL KDAT WD. COLUMN BASE TRIM 1 1/2"1 5/8"3' - 0"2 5/8"3 3/8" 5/8"2 3/4" 2 1/4" 1/4" 3 3/8" 2 5/8" 3' - 0" 3 1/8" 3' - 5 3/4"9 1/8" 7 1/8" 3 1/2" 1 1/2" 1/4" 4 5/8" 11 5/8" 3/4" 1' - 2 1/2" 5" 1' - 0" 5" 5" 5" 1' - 0" 5" 5" 5" 8 1/2" 7 1/2" 1/2" 5 1/2" 8" 8 1/2" 7 1/2" 1/2"4"7 1/2" SIDEWALK CONCRETE SLAB CONCRETE PORCH SLAB FIRST FLOOR HT. PORCH HT. SECOND FLOOR B.O. BEAM LOFT FLR. HT. PORCH RF. RIDGE 2' - 1"1' - 5 1/2"1' - 9"1' - 11 3/4"7' - 0 1/4"1' - 9"1' - 2 3/4"9' - 0 1/4"3" 1' - 8 1/8" ASPHALT SHINGLE ROOFING ROOFING FELT (# PER ROOFING MANF.) 5/8" APA RATED PLYWD. SHEATHING STANDING SEAM METAL ROOF ROOFING FELT (# PER ROOFING MANF.) 5/8" APA RATED PLYWD. SHEATHING 2X10 WD. RAFTERS @ 16" O.C. - TYP. 5/8" APA RATED PLYWD. SHEATHING (2) 2X6 WD. TOP PLATES 2X6 WD. STUDS @ 16" O.C. - TYP. WD. RAFTERS (BEYOND) (2) 2X6 WD. TOP PLATES 5/8" APA RATED PLYWD. SHEATHING 2X6 WD. STUD SILL PLATES WD. BEAM (SEE STRUCT.) 2X6 WD. SILL PLATE (BEYOND) 2X6 WD. CEILING JOISTS @ 16" O.C. - TYP. 1X6 KDAT WD. T&G CEILING 1X6 CEMEN. TRIM PRE-FIN. MTL. FLASH. WD. BEAM (SEE STRUCT.) HORIZ. CEMEN SIDING W/ 7" EXP. 2X6 WD. STUDS @ 16" O.C. - TYP. PRE-FIN. MTL. FLASHING 2X4 KDAT WD. CAP 2X6 KDAT WD. HEAD TRIM WD. HEADER (SEE STRUCT.) IRON PICKET @ GATE IRON PICKET @ GATE KDAT WD. DOOR STILES KDAT WD. DOOR STILES 1X6 KDAT WD. DECK BOARDS 3/4" APA RATED PLYWD. SUBFLOOR 2X WD. SLEEPER TPO MEMBRANE 2X10 WD. RAFTERS @ 16" O.C. - TYP. SIMPSON RAFTER HANGER 1X WD. BLOCKING 1X6 KDAT WD. T&G CEILING 2X6 WD. STUDS @ 16" O.C. - TYP. PRE-FIN. MTL. FLASHING 2X4 KDAT WD. CAP 2X6 KDAT WD. HEAD TRIM WD. HEADER (SEE STRUCT.) IRON PICKET @ GATE KDAT WD. DOOR STILES KDAT WD. DOOR STILES PRE-FIN. MTL. FLASHING ALUM. CLAD / WD. TRANSOM WINDOW ENGINEERED WD. COLUMN 1X6 CEMEN. CORNER BOARDS PT. WD. GATE (BEYOND) HORIZ. SIDING (BEYOND) PT. WD. GATE (BEYOND) 1X6 CEMEN. CORNER BOARDS 11 5/8"4" 5 1/2" 1 1/2" 3/4"11 1/4"3/4" 11 1/2" 5 1/2" 1 1/2" 11 1/4"3/4" 2' - 8 1/8" 7 3/4" COUPOLA RIDGE 1' - 8 3/4"1' - 4 1/8"2' - 8 1/4"1' - 10 1/2" 2X8 WD. ROOF RAFTERS 5/8" APA RATED PLYWD. SHEATH. PRE-FIN. MTL. ROOF RIDGE STANDING SEAM METAL ROOF 1X6 KDAT WD. T&G CEILING (2) 2X6 WD. TOP PLATES 1X4 CEMEN. TRIM (CONT.) PRE-FIN. METAL DRIP EDGE 1X6 CEMEN. TRIM ON 1X6 CEMEN. TRIM 2X WD. BLOCKING (CONT.) 1X6 KDAT WD. T&G SOFFIT 1/4" CEMEN. PANEL 5/4" CEMEN. TRIM @ WIN. HEAD ALUM. CLAD / WD. PICTURE WIN. 2X4 KDAT WD. TRIM PRE-FIN. MTL. PAN FLASHING (2) 2X6 WD. SILL PLATES 1X4 CEMEN. TRIN ON 1X8 CEMEN. TRIM 1X12 CEMEN. TRIM EXTEND ROOFING FELT UP 6" MIN. PRE-FIN. MTL. FLASHING WD. BEAM (SEE STRUCT.) SIMPSON RAFTER HANGER 5/8" AP ARATED PLYWD. SHEATHING ASPHALT SHINGLES ROOFING FELT (# PER ROOFING MANF.) 2X10 WD. RAFTERS @ 16" O.C. - TYP. 1X6 KDAT WD. T&G CEILING 1X12 KDAT WD. TRIM 1X WD. BLOCKING 1X8 KDAT WD. TRIM 1X4 KDAT WD. TRIM 1X KDAT WD. SILL W/ BULLNOSE EDGE 1X KDAT WD. JAMB EXTENSION 1X12 KDAT WD. TRIM 3/8" 10 1/4" 6 7/8" 3 3/8" 1 5/8" 3 1/2" 4 1/8"4 1/2" 4 1/2" 1' - 9 1/8" 12 10 FIRST FLOOR HT. PORCH HT. 4' - 6 1/2"3" 1"5 1/2"1" 2 3/4" 4' - 2 1/8" 3 1/4" 2 3/4" 1/2" 3' - 7 5/8" 1/2" 2 3/4" 4' - 8 1/8" 2X4 WD. DOOR FRAME MEMBER (BEYOND) 1X6 PT. WD. SLATS (BEYOND) PRE-FIN. MTL FLASHING @ CAP (@ GATE)1X6 PT. WD. CAP @ PERIM. PRE-FIN. MTL. FLASHING 1X6 PT. WD. SLATS 1X6 PT. WD. TRIM WRAP @ POST 4X4 PT. WD. POST (BEYOND) 2X4 PT. WD. BRACING @ GATE SIMPSON POST BASE SERVICE YARD CONC. SLAB REINFORCING (SEE STRUCT.) 5 1/4" 5" 5" 5 1/2" GAVLANIZED MTL. HINGES 4 1/2"1" PRE-FIN. MTL FLASHING @ CAP GAVLANIZED MTL. HINGES I SSUE P ROJECT INFO S HEET TITLE D ate P roject No. COPYRIGHT 2019 COURT ATKINS GROUP - THIS DRAWING IS THE PROPERTY OF THE ARCHITECT AND IS NOT TO BE REPRODUCED IN WHOLE OR IN PART BY ANY MEANS OR METHOD WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ARCHITECT. ANY UNAUTHORIZED REPRODUCTION OR REUSE OF THESE DOCUMENTS WILL RESULT IN LEGAL ACTION. POST OFFICE BOX 3978 BLUFFTON, SC 29910 PH: 843.815.2557 FX: 843.815.2547 WWW.COURTATKINS.COM © 1/22/2021 4:31:24 PM 2 021.01.22 2 0-0 95 A5.0 O LD VILLAGE SQUARE - B UILDING 4 6 MARIANNA WAY B LUFFTON, SC 29910 D ETAILS 3/4" = 1'-0"A5.0 1 WALL SECTION @ FRONT PORCH 3/4" = 1'-0"A5.0 2 WALL SECTION @ ENTRY GATE 3/4" = 1'-0"A5.0 3 COUPOLA SECTION DETAIL 3/4" = 1'-0"A5.0 4 SERVICE YARD DETAIL N O. REV. DATE DESCRIPTION ATTACHMENT 4 DORMER RF. BRG. W IN. HD. HT. W IN. SILL HT. D OOR HEAD HT. D OOR HEAD HT. T. O. GUARDRAIL T. O. GUARDRAIL PORCH RF. BRG. T.O. GUARDRAIL T.O. GUARDRAIL F IRST FLOOR HT. P ORCH HT. S ECOND FLOOR L OFT FLR. HT. 7 "4 ' - 8"3 ' - 1"3 ' - 9"3 ' - 2 7/8"3 ' - 9 1/8"3 ' - 0"5 ' - 5 7/8"3 ' - 6 1/8"3 " 4 1/2" 5 1/2" 1' - 7 3/4" ALUM. CLAD / WD. DOUBLE HUNG WIN. WD. HEADER (SEE STRUCT.) 2X6 KDAT WD. TRIM @ HEAD 1X6 KDAT WD. T&G SOFFIT 1X4 CEMEN. TRIM ON 1X8 CEMEN TRIM PRE-FIN. MTL. DRIP EDGE 5/8" APA RATED PLYWD. SHEATHING ROOFING FELT (# PER ROOFING MANF.) STANDING SEAM METAL ROOF 2X WD. BLOCKING (CONT.) 4 1/2" 1 1/2" 5 5/8" 3 5/8" 5/4"X6 KDAT WD. TRIM @ SILL PRE-FIN. METAL SILL FLASHING PRE-FIN. MTL. FLASHING STANDING SEAM METAL ROOF 5/8" APA RATED PLYWD. SHEATHING 2X8 WD. RAFTERS @ 16" O.C. - TYP. JOIST HANGER 2X WD. BLOCKING (CONT.) 5/8" APA RATED PLYWD. SHEATHING (2) 2X6 WD. SILL PLATES 3/4" APA RATED PLYWD. SUBFLOOR R-19 BATT INSULATION 1X6 KDAT WD. T&G CEILING 1X6 CEMEN. TRIM PRE-FIN. MTL. FLASHING (2) 2X6 WD. TOP PLATES HORIZ. CEMEN. SIDING W/ 7" EXP. R-19 BATT INSULATION PRE-FIN. MTL. FLASHING 2X4 KDAT WD. TRIM (CHAMFER TO DRAIN) 2X6 KDAT WD. HEAD TRIM WD. HEADER (SEE STRUCT.) 5 3/4" 1 1/2" ALUM. CLAD / WD. PATIO DOOR CEMEN. TRIM (BEYOND) 10X10 ENFINEERED WD. COLUMN PT. WD. GATE (BEYOND) GALVANIZED METAL HINGES SWEEP TYPICAL @ EXT. DOORS ADA "ROLL-IN" DOOR SILL 1X6 PT. WD. DECK BOARDS TPO WATER PROOF MEMBRANE 3/4" APA RATED PLYWD. SUBFLOOR JOIST HANGER 2X6 WD. CEILING JOISTS 1X6 KDAT WD. T&G CEILING 1X6 CEMEN. TRIM PRE-FIN. MTL. FLASHING HORIZ. CEMEN. SIDING W/ 7" EXP. (2) 2X6 WD. TOP PLATES PRE-FIN. MTL. FLASHING 2X4 KDAT WD. TRIM (CHAMFER TO DRAIN) 2X6 KDAT WD. HEAD TRIM 5 3/4" 1 1/2" ALUM. CLAD / WD. PATIO DOOR W/ TRANSOM WINDOW 10X10 ENFINEERED WD. COLUMN PT. WD. GATE (BEYOND) GALVANIZED METAL HINGES SWEEP TYPICAL @ EXT. DOORS 2X4 KDAT WD. SILL TRIM 8" 1' - 4" 1/2" 3 1/2" 7 1/2" 5" 4"8" 4"5" 3/4"1' - 4"5/8" 1 1/2" 3/4"1' - 4"5/8" 1 1/2" 5 1/8" FIRST FLOOR HT. PORCH HT. SECOND FLOOR B.O. BEAM 1' - 2 7/8"5' - 2 7/8"3' - 9 1/8"8' - 5 7/8"3' - 6 1/8"3" 3' - 5 3/4" 3' - 5 3/4" 1X3 PT. WD. HORIZ. RAIL MEMBER 1X4 PT. WD. BOTTOM RAIL 1X6 PT. WD. DECK BOARDS 2X WD. SLEEPER (@ SLOPE 1/8" / FT.) 2X KDAT WD. TRIM (CHAMFER TO DRAIN) KDAT WD. COLUMN BASE TRIM 1X4 CEMEN. TRIM ON 1X10 CEMEN. TRIM EXTEND TPO MEMBRANE OVER EDGE ONTO TPO COATED MTL. FLASHING 1X4 WD. BLOCKING 5/8" APA RATED PLYWD. SHEATHING WD. BEAM (SEE STRUCT.) 1X12 CEMEN. TRIM 2X WD. FRAMING 1X CEMEN. TRIM 9 1/4" 7" 3 1/2" 1" 1 5/8" 3' - 0" 1 5/8" 1 1/2"1" 1 5/8" 3' - 0" 1 5/8" 1 1/2" 10X10 ENGINEERED WD. COLUMN 2X4 PT. WD. GUARDRTAIL CAP (CHAMFER TO DRAIN) 1X3 PT. WD. HORIZ. RAIL MEMBER 1X1 PT. WD. PICKETS KDAT WD. COL. CAPITAL TRIM WD. BEAM (SEE STRUCT.) 1X4 CEMEN. TRIM ON 1X10 CEMEN. TRIM 1X6 KDAT WD. T&G SOFFIT 1X4 CEMEN. TRIM ON 1X8 CEMEN TRIM 1 1/2" 5 5/8" 3 5/8" PRE-FIN. MTL. DRIP EDGE 5/8" APA RATED PLYWD. SHEATHING ROOFING FELT (# PER ROOFING MANF.) STANDING SEAM METAL ROOF 2X WD. BLOCKING (CONT.) 10X10 ENGINEERED WD. COLUMN 2X4 PT. WD. GUARDRTAIL CAP (CHAMFER TO DRAIN) 1X3 PT. WD. HORIZ. RAIL MEMBER 1X1 PT. WD. PICKETS 1X3 PT. WD. HORIZ. RAIL MEMBER 1X4 PT. WD. BOTTOM RAIL KDAT WD. COLUMN BASE TRIM FINISHED GRADE FOUNDATION (SEE STRUCT.) 7 1/2" 9" 7 1/2" 4"7 1/2" 1/4" 7 3/8" 3 5/8" 1' - 7 3/8" 5 1/2" 5 1/2"7 3/4" 4" 3 3/8" 1X CEMEN. TRIM JOIST HANGER 2X8 WD. RAFTERS @ 16" O.C. - TYP. JOIST HANGER SECOND FLOOR 5/8" 1' - 4" 3/4" 1 1/2" 3/4"3/4" 2 1/2" CEMEN. HORIZ. SIDING W/ 7" EXP. - TYP. 5/8" APA RATED PLYWD. SHEATHING (1) LAYER COMM. BUILDING WRAP WD. STARTER STRIP (PER SIDING MANF.) PRE-FIN. METAL FLASHING W/ SEALANT 2X4 KDAT WD. TRIM (ANGLE TO DRAIN) 1X4 CEMEN. TRIM 1X10 CEMEN. TRIM PRE-FIN. MTL. FLASHING W/ SEALANT CEMEN. HORIZ. SIDING W/ 7" EXP. - TYP. WD. RIM JOIST - TYP. (2) 2X6 WD. TOP PLATES R-19 BATT INSULATION 6 7/8" 3 1/4" 1 1/2" 3/8" I SSUE P ROJECT INFO S HEET TITLE D ate P roject No. COPYRIGHT 2019 COURT ATKINS GROUP - THIS DRAWING IS THE PROPERTY OF THE ARCHITECT AND IS NOT TO BE REPRODUCED IN WHOLE OR IN PART BY ANY MEANS OR METHOD WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ARCHITECT. ANY UNAUTHORIZED REPRODUCTION OR REUSE OF THESE DOCUMENTS WILL RESULT IN LEGAL ACTION. POST OFFICE BOX 3978 BLUFFTON, SC 29910 PH: 843.815.2557 FX: 843.815.2547 WWW.COURTATKINS.COM © 1/22/2021 4:31:28 PM 2 021.01.22 2 0-0 95 A5.1 O LD VILLAGE SQUARE - B UILDING 4 6 MARIANNA WAY B LUFFTON, SC 29910 D ETAILS NO. REV. DATE DESCRIPTION 3/4" = 1'-0"A5.1 1 WALL SECTION @ TYP. EXT. WALL 3/4" = 1'-0"A5.1 2 WALL SECTION @ TYP. PORCH 1 1/2" = 1'-0"A5.1 3 TYP. WATERTABLE ATTACHMENT 4 DOOR HEAD HT. TRANSOM HD. HT. FIN. FLR. FIN. FLR. WIN. HD. HT. TRANSOM HD. HT. WIN. HD. HT. WIN. HD. HT. WIN. HD. HT. EXTERIOR GATE SYSTEM INSWING GATE PAIR 2'-8" x 7'-3" (R.O. ±5'-4" x 9'-3") 3/4" X 3/4" PICKETS (PATTERN AS SHOWN) MANUFACTURER T.B.D. BY G.C. / OWNER ADJUST DOOR HEIGHT TO ENSURE TRUE 9'-0" & 9'-3" ROUGH OPNGS. - TOP OF DOOR & TANSOMS TO ALIGN W/ TOP OF ADJACENT DRS. 100 1 3/4"1 3/4" 2' - 10" 2' - 10" 2' - 10" 1 3/4" 1 3/4" 1' - 9"3"4' - 2"2' - 10" 1' - 9"3"4' - 2"2' - 10" 1 3/4" 1 3/4" 1' - 9"3"4' - 5"2' - 10" 1" 1" 1/2" 2" 2" 2" 2" 1/2" 4 1/2" 6' - 8" 2" 1/2" 9' - 3" 7' - 3" 5' - 4" 2' - 8" 2' - 8" 5' - 4" 2' - 8" 2' - 8" 9' - 0" 1/2" 4"4" 1/2" 4" 1/2"4" 4" 3' - 0" 4"5' - 11"8 1/2" 4"4' - 8"4"1' - 4"4" 1 3/4" 1/2" 3 1/2" 1' - 2" 1/2" 3 1/2" 1' - 2" 3' - 0" 1/2"4"5' - 11"8 1/2" 4"6' - 0"8" 1/2" 3 1/2" 1' - 2" 3' - 0" SEE SCHED. SEE SCHEDULE SEE SCHED. SEE SCHEDULE EXTERIOR DOOR SYSTEM OUTSWING DOOR PAIR 2'-8" x 7'-0" (R.O. ±5'-4" x 9'-0") SDL MUNTINS W/ SPACE BAR (PATTERN AS SHOWN) MANUF. T.B.D. BY G.C. / OWNER DP RATING 50 OR APPROVED EQ. ADJUST DOOR HEIGHT TO ENSURE TRUE 9'-0" & 9'-3" ROUGH OPNGS. - TOP OF DOOR & TRANSOMS TO ALIGN W/ TOP OF ADJACENT DRS. 103A 7' - 0" 7' - 0" 7' - 0" 104B EXTERIOR DOOR SYSTEM OUTSWING DOOR 3'-0" x 7'-0" (R.O. ±3'-0" x 9'-0") SDL MUNTINS W/ SPACE BAR (PATTERN AS SHOWN) MANUF. T.B.D. BY G.C. / OWNER DP RATING 50 OR APPROVED EQ. ADJUST DOOR HEIGHT TO ENSURE TRUE 9'-0" & 9'-3" ROUGH OPNGS. - TOP OF DOOR & TRANSOMS TO ALIGN W/ TOP OF ADJACENT DRS. 103 104 9' - 0" EXTERIOR DOOR SYSTEM OUTSWING DOOR 3'-0" x 7'-0" (R.O. ±3'-0" x 7'-0") MANUF. T.B.D. BY G.C. / OWNER DP RATING 50 OR APPROVED EQ. ADJUST DOOR HEIGHT TO ENSURE TRUE 7'-0" ROUGH OPNGS. - TOP OF DOOR & TRANSOMS TO ALIGN W/ TOP OF ADJACENT DRS. 101 102 EXTERIOR DOOR SYSTEM OUTSWING DOOR 3'-0" x 7'-0" (R.O. ±3'-0" x 7'-0") SDL MUNTINS W/ SPACE BAR (PATTERN AS SHOWN) MANUF. T.B.D. BY G.C. / OWNER DP RATING 50 OR APPROVED EQ. ADJUST DOOR HEIGHT TO ENSURE TRUE 7'-0" ROUGH OPNGS. - TOP OF DOOR & TRANSOMS TO ALIGN W/ TOP OF ADJACENT DRS. 301D 302D INTERIOR DOOR SYSTEM SOLID CORE WOOD 2 PANEL MANUF. T.B.D. BY G.C. / OWNER SEE SCHEDULE FOR ADDITIONAL INFORMATION INTERIOR DOOR SYSTEM SOLID CORE WOOD 2 PANEL - DOUBLE MANUF. T.B.D. BY G.C. / OWNER SEE SCHEDULE FOR ADDITIONAL INFORMATION 1/2"4' - 1 1/2"2' - 10" 4 1/2" 6' - 5" 2 1/2" 7' - 0" 5' - 4" 2' - 8" 2' - 8" 1" 1" EXTERIOR GATE SYSTEM INSWING GATE PAIR 2'-8" x 7'-0" (R.O. ±5'-4" x 7'-0") 3/4" X 3/4" PICKETS (PATTERN AS SHOWN) MANUFACTURER T.B.D. BY G.C. / OWNER ADJUST DOOR HEIGHT TO ENSURE TRUE 9'-0" & 9'-3" ROUGH OPNGS. - TOP OF DOOR & TANSOMS TO ALIGN W/ TOP OF ADJACENT DRS. 100 2' - 0"7' - 0"3" 4" 2' - 4" 4" 3' - 8" 4" 7' - 0" 1 3/4" 2' - 10" 1 2 3 4 5 6 8 9 4' - 2"2' - 10" 1 3/4" 1 3/4" 1/2" 4"4" 1/2" 4" 1/2"4" 4" 1/2"4"5' - 11"8 1/2" 7' - 0" 2' - 8" 2' - 8" 5' - 4" EXTERIOR DOOR SYSTEM OUTSWING DOOR PAIR 2'-8" x 7'-0" (R.O. ±5'-4" x 7'-0") SDL MUNTINS W/ SPACE BAR (PATTERN AS SHOWN) MANUF. T.B.D. BY G.C. / OWNER DP RATING 50 OR APPROVED EQ. ADJUST DOOR HEIGHT TO ENSURE TRUE 7'-0" ROUGH OPNGS. - TOP OF DOOR & TRANSOMS TO ALIGN W/ TOP OF ADJACENT DRS. 103 7 SEE SCHED. SEE SCHEDULE SLIDE SLIDE INTERIOR DOOR SYSTEM SOLID CORE WOOD 2 PANEL - DOUBLE MANUF. T.B.D. BY G.C. / OWNER SEE SCHEDULE FOR ADDITIONAL INFORMATION 10 1' - 6" 5' - 6" 3" 1' - 9" 9' - 0" 2' - 8" 1" 5' - 6" 1" 1' - 4"1' - 4"7' - 6" 2' - 8"4' - 4" 2' - 8" 2' - 8"4' - 4" 7' - 0" 1" 2' - 8" 2' - 8" 1" 2' - 8" 2' - 8"4' - 4" 1' - 4" 1" 2' - 8" 1" 1' - 4" 5' - 0"2' - 0" 7' - 0" 7' - 0" 2' - 8" 4' - 8"3'-1" ALF 7'-9" ABOVE LOFT FLOOR 17'-9 1/2" ABOVE LOFT FLOOR 2' - 8"15'-1 1/2" ALF 2' - 8" FIN. FLOOR KDAT WD. SHUTTERS WROUGHT IRON SHUTTER DOG WROUGHT IRON SHUTTER DOG WROUGHT IRON SHUTTER DOG KDAT WD. SHUTTER KDAT WD. SHUTTER WROUGHT IRON SHUTTER DOG KDAT WD. SHUTTERS CLAD DOUBLE HUNG UNITS 2'-8" x 5'-6" (R.O. ± 2'-8" x 7'-6") SDL MUNTINS W/ SPACER BAR (PATTERN AS SHOWN) MANUF. T.B.D. BY G.C. / OWNER DP RATING 50 OR APPROVED EQUAL A CLAD PICTURE UNITS 2'-8" x 2'-8" (R.O. ± 2'-8" x 2'-8") SDL MUNTINS W/ SPACER BAR (PATTERN AS SHOWN) MANUF. T.B.D. BY G.C. / OWNER DP RATING 50 OR APPROVED EQUAL B CLAD CASEMENT UNITS 2'-8" x 2'-8" (R.O. ± 2'-8" x 2'-8") SDL MUNTINS W/ SPACER BAR (PATTERN AS SHOWN) MANUF. T.B.D. BY G.C. / OWNER DP RATING 50 OR APPROVED EQUAL C CLAD CASEMENT UNITS 2'-8" x 2'-8" (R.O. ± 2'-8" x 2'-8") SDL MUNTINS W/ SPACER BAR (PATTERN AS SHOWN) MANUF. T.B.D. BY G.C. / OWNER DP RATING 50 OR APPROVED EQUAL D CLAD DOUBLE HUNG UNITS 2'-8" x 5'-0" (R.O. ± 2'-8" x 5'-0") SDL MUNTINS W/ SPACER BAR (PATTERN AS SHOWN) MANUF. T.B.D. BY G.C. / OWNER DP RATING 50 OR APPROVED EQUAL E CLAD DOUBLE HUNG UNITS 2'-8" x 4'-8" (R.O. ± 2'-8" x 4'-8") SDL MUNTINS W/ SPACER BAR (PATTERN AS SHOWN) MANUF. T.B.D. BY G.C. / OWNER DP RATING 50 OR APPROVED EQUAL F CLAD PICTURE UNITS 2'-8" x 2'-8" (R.O. ± 2'-8" x 2'-8") SDL MUNTINS W/ SPACER BAR (PATTERN AS SHOWN) MANUF. T.B.D. BY G.C. / OWNER DP RATING 50 OR APPROVED EQUAL G 9' - 0" 2' - 8"2'-7" ALF 7' - 0" CLAD PICTURE UNITS 2'-8" x 2'-8" (R.O. ± 2'-8" x 2'-8") SDL MUNTINS W/ SPACER BAR (PATTERN AS SHOWN) MANUF. T.B.D. BY G.C. / OWNER DP RATING 50 OR APPROVED EQUAL H 2' - 8" KDAT WD. SHUTTER KDAT WD. SHUTTER 5 '-7" ABOVE LOFT FLR. 1' - 4" 1" 2' - 8" 1" 1' - 4"2 1/2" 1/2" 1/2"1/2" 2 1/2" 2 3/4" 3/4" VARIES 1" 2 3/4"VARIES1"VARIES EQ EQ 2 1/2" VARIES 2 1/2" VARIES 2 1/2" VARIES 2 1/2" VARIES 2 1/2"1/2" 1 1/2" 5 3/4" 1 1/2" 1 1/2" 2" 2X KDAT WD. HEAD TRIM (CHAMFER TO DRAIN) 1X CEMEN. HEAD TRIM IRON HINGES (BEYOND) 1X KDAT WD. STILE 1/2" X 1/4" KDAT WD. FLAT STOCK 1/4" KDAT WD. PANEL 1X KDAT WD. RAIL 1/4" KDAT WD. PANEL 1/2" X 1/4" KDAT WD. FLAT STOCK IRON HINGES (BEYOND) 1X KDAT WD. STILE IRON SHUTTER DOG 1X KDAT WD. RAIL 2X WD. SILL (CHAMFER TO DRAIN ALUM. CLAD /WD. DIOUBLE HUNG WINDOW 1X KDAT WD. TRIM 1X KDAT WD. RAIL 1X KDAT WD. TRIM I SSUE P ROJECT INFO S HEET TITLE D ate P roject No. COPYRIGHT 2019 COURT ATKINS GROUP - THIS DRAWING IS THE PROPERTY OF THE ARCHITECT AND IS NOT TO BE REPRODUCED IN WHOLE OR IN PART BY ANY MEANS OR METHOD WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ARCHITECT. ANY UNAUTHORIZED REPRODUCTION OR REUSE OF THESE DOCUMENTS WILL RESULT IN LEGAL ACTION. POST OFFICE BOX 3978 BLUFFTON, SC 29910 PH: 843.815.2557 FX: 843.815.2547 WWW.COURTATKINS.COM © 1/22/2021 4:31:36 PM 2 021.01.22 2 0-0 95 A6.0 O LD VILLAGE SQUARE - B UILDING 4 6 MARIANNA WAY B LUFFTON, SC 29910 D OOR AND W INDOW S CHEDULE WINDOW SCHEDULE TYPE MARK WINDOW TYPE DESCRPITION R.O. HEAD HEIGHT DESIGN PRESSURE COMMENTSWIDTH HEIGHT A CLAD DOUBLE HUNG UNIT 2'-8" x 5'-0" 2' - 8" 7' - 6" 9' - 0" B CLAD TRANSOM UNIT 2'-8" x 2'-8" 2' - 8" 2' - 8" 7' - 0 " C CLAD CASEMENT UNIT 2''-8" x 2'-8" 2' - 8" 2' - 8" 7' - 0" D CLAD CASEMENT UNIT 2''-8" x 2'-8" 2' - 8" 2' - 8" 7' - 0" E CLAD DOUBLE HUNG UNIT 2'-8" x 5'-0" 2' - 8" 5' - 0" 7' - 0" F CLAD DOUBLE HUNG UNIT 2'-8" x 4'-8" 2' - 8" 4' - 8" 7' - 9" G CLAD PICTURE UNIT 2'-8" x 2'-8" 2' - 8" 2' - 8" 17' - 9 1/2" H CLAD PICTURE UNIT 2'-8" x 2'-8" 2' - 8" 2' - 8" 5' - 3 " DOOR SCHEDULE NO. ROOM WIDTH HEIGHT DOOR FRAME HARDWARE COMMENTSTYPE MATERIAL FINISH RATED MAT'L FINIS H RATED LOCK CLOSER STOP PANIC MISC 201F CLOSET 1 4' - 0" 7' - 0" 9 SOLID CORE MDF PTD. WD. PTD . PASSAGE 201G BATHROOM 1 2' - 6" 7' - 0" 8 SOLID CORE MDF PTD. WD. P TD. PRIVACY X 201H LAUNDRY 4' - 0" 7' - 0" 9 SOLID CORE MDF PTD. WD. PTD. PASSAGE 202 KITCHEN, LIVING & DINING 3' - 0" 7' - 0" 6 ALUM. CLA D / WD. F.A.F. WD. F.A.F. ENTRY X 202A OPEN AIR PORCH 5' - 4" 7' - 0" 7 ALUM. CLAD / WD. F. A.F. WD. F.A.F. ENTRY 202B KITCHEN, LIVING & DINING 2' - 8" 6' - 11 1/2" 8 SOL ID CORE MDF PTD. WD. PTD. PRIVACY X 202C BEDROOM 2 4' - 0" 7' - 0" 9 SOLID CORE MDF PTD. WD. PT D. PASSAGE 202D VESTIBULE 2 2' - 6" 7' - 0" 8 SOLID CORE MDF PTD. WD. PTD. PRIVACY X 202E VESTIBULE 2 2' - 8" 7' - 0" 8 SOLID CORE MDF PTD. WD. PTD. PRIVACY X 202F VESTIBULE 1 4' - 0" 7' - 0" 9 SOLID CORE MDF PTD. WD. PTD. PASSAGE 202G VESTIBULE 1 2' - 6" 7' - 0" 8 SOLID CORE MDF PTD. WD. PTD. PRIVACY X 202H KITCHEN, LIVING & DINING 4' - 0" 7' - 0" 9 SOLID CO RE MDF PTD. WD. PTD. PASSAGE 301 KITCHEN, DINING & LIVING 3' - 0" 7' - 0" 6 ALUM. CLA D / WD. F.A.F. WD. F.A.F. ENTRY 301A KITCHEN, DINING & LIVING 5' - 0" 7' - 0" 9 SOLID CO RE MDF PTD. WD. PTD. PASSAGE 301B KITCHEN, DINING & LIVING 2' - 8" 7' - 0" 9 SOLID CO RE MDF PTD. WD. PTD. PRIVACY X 301C BEDROOM 2 4' - 0" 7' - 0" 10 SOLID CORE MDF PTD. WD. P TD. PRIVACY 301D BALCONY 3' - 0" 7' - 0" 6 ALUM. CLAD / WD. F.A.F. WD. F.A.F. ENTRY 301E KITCHEN, DINING & LIVING 2' - 6" 7' - 0" 8 SOLID CO RE MDF PTD. WD. PTD. PRIVACY X 301F BEDROOM 1 2' - 8" 7' - 0" 8 SOLID CORE MDF PTD. WD. PT D. PRIVACY X 301G CLOSET 1 6' - 0" 7' - 0" 10 SOLID CORE MDF PTD. WD. PT D. PASSAGE 302 KITCHEN, DINING & LIVING 3' - 0" 7' - 0" 6 ALUM. CLA D / WD. F.A.F. WD. F.A.F. ENTRY X 302A LAUNDRY 5' - 0" 7' - 0" 9 SOLID CORE MDF PTD. WD. PTD. PASSAGE 302B BEDROOM 2 2' - 8" 7' - 0" 9 SOLID CORE MDF PTD. WD. PT D. PRIVACY X 302C CLOSET 2 4' - 0" 7' - 0" 10 SOLID CORE MDF PTD. WD. PT D. PRIVACY 302D BALCONY 3' - 0" 7' - 0" 6 ALUM. CLAD / WD. F.A.F. WD. F.A.F. ENTRY 302E BATHROOM 2' - 6" 7' - 0" 8 SOLID CORE MDF PTD. WD. PTD . PRIVACY X 302F KITCHEN, DINING & LIVING 2' - 8" 7' - 0" 8 SOLID CO RE MDF PTD. WD. PTD. PRIVACY X 302G BEDROOM 1 6' - 0" 7' - 0" 10 SOLID CORE MDF PTD. WD. P TD. PASSAGE DOOR SCHEDULE NO. ROOM WIDTH HEIGHT DOOR FRAME HARDWARE COMMENTSTYPE MATERIAL FINISH RATED MAT'L FINIS H RATED LOCK CLOSER STOP PANIC MISC 100 ENTRY PORCH 5' - 4" 9' - 3" 1 WROUGHT IRON PWDR. COAT WD. PTD. ENTRY X 101 ELEC. RM. 3' - 0" 7' - 0" 5 HOLLOW MTL. PTD. H.M. PTD. S ECURITY 102 FIRE RISER 3' - 0" 7' - 0" 5 HOLLOW MTL. PTD. H.M. PTD. SECURITY 103 KITCHEN / DINING & LIVING 3' - 0" 9' - 0" 4 ALUM. CL AD / WD. F.A.F. WD. F.A.F. ENTRY X 103A OPEN AIR PORCH 5' - 4" 9' - 0" 3 ALUM. CLAD / WD. F. A.F. WD. F.A.F. SECURITY 103B BUSINESS OFFICE 3' - 0" 7' - 0" 6 ALUM. CLAD / WD. F .A.F. WD. F.A.F. SECURITY 103C CLOSET 2 3' - 6" 7' - 0" 9 SOLID CORE MDF PTD. WD. PTD . PASSAGE 103D BUSINESS OFFICE 2' - 6" 7' - 0" 8 SOLID CORE MDF PTD . WD. PTD. PRIVACY X 103E BEDROOM 1 2' - 8" 7' - 0" 8 SOLID CORE MDF PTD. WD. PT D. PRIVACY X 103F CLOSET 1 4' - 0" 7' - 0" 9 SOLID CORE MDF PTD. WD. PTD . PASSAGE 103G BATHROOM 1 2' - 6" 7' - 0" 8 SOLID CORE MDF PTD. WD. P TD. PRIVACY X 103H LAUNDRY 4' - 0" 7' - 0" 9 SOLID CORE MDF PTD. WD. PTD. PASSAGE 104 KITCHEN / DINING & LIVING 3' - 0" 9' - 0" 4 ALUM. CL AD / WD. F.A.F. WD. F.A.F. ENTRY X 104A OPEN AIR PORCH 5' - 4" 9' - 0" 3 ALUM. CLAD / WD. F. A.F. WD. F.A.F. ENTRY 104B KITCHEN / DINING & LIVING 2' - 8" 6' - 11 1/2" 8 SO LID CORE MDF PTD. WD. PTD. PRIVACY X 104C BEDROOM 2 4' - 0" 7' - 0" 9 SOLID CORE MDF PTD. WD. PT D. PASSAGE 104D VESTIBULE 1 2' - 6" 7' - 0" 8 SOLID CORE MDF PTD. WD. PTD. PRIVACY X 104E VESTIBULE 1 2' - 8" 7' - 0" 8 SOLID CORE MDF PTD. WD. PTD. PRIVACY X 104F VESTIBULE 2 4' - 0" 7' - 0" 9 SOLID CORE MDF PTD. WD. PTD. PASSAGE 104G VESTIBULE 2 2' - 6" 7' - 0" 8 SOLID CORE MDF PTD. WD. PTD. PRIVACY X 104H KITCHEN / DINING & LIVING 4' - 0" 7' - 0" 9 SOLID C ORE MDF PTD. WD. PTD. PASSAGE 200 COMMUNITY PORCH 5' - 4" 7' - 0" 2 WROUGHT IRON PWDR. COAT WD. PTD. ENTRY 201 KITCHEN, LIVING & DINING 3' - 0" 7' - 0" 6 ALUM. CLA D / WD. F.A.F. WD. F.A.F. ENTRY X 201A OPEN AIR PORCH 5' - 4" 7' - 0" 7 ALUM. CLAD / WD. F. A.F. WD. F.A.F. ENTRY 201B BEDROOM 2 2' - 8" 6' - 11 1/2" 8 SOLID CORE MDF PTD. WD. PTD. PRIVACY X 201C CLOSET 2 4' - 0" 7' - 0" 9 SOLID CORE MDF PTD. WD. PTD . PASSAGE 201D BATHROOM 2 2' - 6" 7' - 0" 8 SOLID CORE MDF PTD. WD. P TD. PRIVACY X 201E BEDROOM 1 2' - 8" 7' - 0" 8 SOLID CORE MDF PTD. WD. PT D. PRIVACY X NO. REV. DATE DESCRIPTION 3/4" = 1'-0"A6.0 1 TYPICAL WINDOW ELEVATION ATTACHMENT 4 OVERALL SITE PLAN - BUILDINGS 3 & 4 PHASE L100 SITE DEVELOPMENT PLANS FOR 6 SHULTS ROAD BLUFFTON, SOUTH CAROLINA DRAWING NUMBER DRAWING TITLE DESIGN CONCEPTS, DRAWING, SHEETS, LOGOS, SPECIFICATIONS, DETAILS, WRITTEN MATERIAL SHALL NOT BE USED OR REPRODUCED IN WHOLE OR IN PART IN ANY FORM WITHOUT PRIOR WRITTEN CONSENT OF WJK LTD. © 2020 WJK LTD. THIS SHEET TO SCALE AT: 24"X36" DATE: PROJECT NO.: DRAWN BY: CHECKED BY: JAN 15, 2021 20106.01 JM DK REVISIONS: c N EW BUILDINGS 3 & 4 PHASE L.O.W. BUILDINGS 3 & 4 PHASE L.O.W. BUILDINGS 3 & 4 PHASE L.O.W. BUILDINGS 3 & 4 PHASE L.O.W. EXISTING EXISTING FUTURE PHASE 020406080 10305070 Scale 1 " = 20' PREVIOUSLY APPROVED SITE & LANDSCAPE PLAN ATTACHMENT 5 PLANTING PLAN - BUILDINGS 3 & 4 PHASE L500 SITE DEVELOPMENT PLANS FOR 6 SHULTS ROAD BLUFFTON, SOUTH CAROLINA DRAWING NUMBER DRAWING TITLE DESIGN CONCEPTS, DRAWING, SHEETS, LOGOS, SPECIFICATIONS, DETAILS, WRITTEN MATERIAL SHALL NOT BE USED OR REPRODUCED IN WHOLE OR IN PART IN ANY FORM WITHOUT PRIOR WRITTEN CONSENT OF WJK LTD. © 2020 WJK LTD. THIS SHEET TO SCALE AT: 24"X36" DATE: PROJECT NO.: DRAWN BY: CHECKED BY: JAN 15, 2021 20106.01 JM DK REVISIONS: c N EW 010203040 5152535 Scale 1 " = 10' BUILDINGS 3 & 4 PLANT SCHEDULE: EXISTING LIVE OAK TO REMAIN, TYP. 1 QUEV 1 QUEV 1 QUEV BUILDINGS 3 & 4 PHASE L.O.W. BUILDINGS 3 & 4 PHASE L.O.W. BUILDINGS 3 & 4 PHASE L.O.W. BUILDINGS 3 & 4 PHASE L.O.W. OVERALL TREE CANOPY GREATER THAN 75% COVERAGE EXISTING EXISTING FUTURE PHASE 30 TRAA 20 TRAA 40 TRAA 5 ILNS 5 VIBS 1 MAGG 1 MAGG 5 ILEV EXISTING TREE CANOPY TO REMAIN, TYP. ATTACHMENT 5 PLAN REVIEW COMMENTS FOR COFA-01-21-014892 Town of Bluffton Department of Growth Management 20 Bridge Street P.O. Box 386 Bluffton, South Carolina 29910 Telephone 843-706-4522 OLD TOWN Plan Type: Apply Date: Plan Status: Plan Address: 6 Marianna Way Way BLUFFTON, SC 29910 Historic District Active 01/11/2021 Plan PIN #:Case Manager: R610 039 000 0746 0000Katie Peterson Plan Description: A request by Court Atkins Architects, on behalf of the owner, Herkus, LLC, for review of a Certificate of Appropriateness to allow the construction of a new 2 1/2 -story multifamily residential building of approximately 5,328 SF located at 6 Marianna Way, Building 4 in the Old Village Square development, in the Old Town Bluffton Historic District and zoned Neighborhood General – HD. [[Building 4-OVS]] STATUS [1-12-2021]: The application received 1-11-2021 is currently being reviewed by Staff for conformance with the Unified Development Ordinance (UDO), Traditional Construction Patterns, and any development plans associated with the parcel and is scheduled for review by the HPRC at the 1-20-2021 meeting. Please note all comments provided at this meeting reflect the 1-11 submittal and do not take into consideration the revised drawings submitted 1-19-2021. Staff Review (HD) Submission #: 1 Recieved: 01/15/2021 Completed: 01/19/2021 Reviewing Dept. Complete Date StatusReviewer Revisions Required01/19/2021Growth Management Dept Review (HD) Katie Peterson Comments: 01/19/2021 Page 1 of 3 ATTACHMENT 6 1. Multifamily is not a permitted use in the Neighborhood General – HD zoning district. (4.3) 2. Applicants are required to provide notice via certified mail to all owners of property, including any Property Owners Association (POA) abutting, adjacent or contiguous to the property that is subject of the application within fifteen (15) days of the UDO Administrator’s acceptance of a completed application. Upon submittal of the Final Application, a list of adjacent property owners and a letter template will be sent. (3.2.4.) 3. At time of final submittal the following fields on the application must be updated: address is 6 Marianna Way, as this is a new application, there are no previous applications and all fields must be completed, the existing square footage is 0, the plans must be printed to scale. (Applications Manual) 4. This structure will be reviewed as an Additional Building Type. The proposed structure most closely meets the characteristics of the Mansion Apartment House (use, size, number of units, appearance, defined central primary entrance, center hall in format), however does not meet all of the characteristics (no full-length shared porch, exceeds width, unit SF slightly under). It does not meet the characteristics of a Center Hall House (does not meet use, max SF, have side or rear wings secondary to the mass and exceeds typical width), with the exception of the footprint. Mansion Apartment House building types are not permitted in the NG-HD zoning district, however, this structure would be reviewed as an Additional Building Type with characteristics of the Mansion Apartment House. *Note: the building type may be altered when the use and other architectural standards are updated. 5. Overall building proportions and individual building features shall have a proportional relationship with one another, as well as the overall building form. The central portico appears under-scaled relative to the overall width of both buildings. Additionally, the glazing on the rear elevations appears to have under-scaled glazing resulting in large areas of blank walls. (Sec. 5.15.5.F.4.a.) 6. Residential structures shall have a first finished floor height raised a minimum of three (3) feet above average adjacent sidewalk grade. *Note: See comment 1 (5.15.5.F.1.c.) 7. Porches shall be a minimum of 6’ in depth. The side porches on the first floor are 5’ deep. The depth must be increased to meet the minimum depth requirement. *Note: See comment 1 (5.15.6.E.5.a) 8. Porch height shall be 30” minimum from grade to top of stairs. The porches are currently proposed at grade and must be raised to no less than 30”. *Note: See comment 1 (5.15.6.E.5.c.) 9. The Architectural standards encourage Bluffton vernacular architecture and construction which is straightforward and functional, and which draws its ornament and variety from the traditional assembly of genuine materials. The porches on either side of the second floor do not have any access and are not functional. Provide access or reconfigure the ends of the structure to a more traditional configuration. (5.15.6.A.) 10. Doors are permitted to be wood, metal or metal-clad. The door schedule lists doors 101 and 102, located on the rear exterior elevation, as insulated fiberglass. The door material must be revised to a permitted material (5.15.6.I.2.b.) 11. Roofs are permitted to be gabled, hipped, and shed. The structure proposes the use of a half-hipped roof. A determination on the appropriateness of this alternate roof shape is required prior to approval. (5.15.6.J.1.a.) 12. Rooflines shall be simple, utilizing gables, hips, and sheds, or combinations of these basic forms. Roofs shall correspond to the major massing of the building; roof forms that overwhelm the mass of the primary building form and complicated rooflines are to be avoided. As the proposed structure incorporates hip, gable, half-gable and shed roofs, the number of roof profiles is complicated by the number of materials proposed on the structure. Consider revising the roofing material to be single material. (5.15.5.F.2.b.) 13. The Old Town Bluffton Historic District embodies a diverse community character. Structures range from stately homes, unique shops, historic structures nestled among new construction infill. The proposed building plans for 6 and 10 Marianna Way are identical This is not representative of the architectural diversity of Old Town Bluffton Historic District, nor does this exist elsewhere within the District. Building elements should be reconsidered to introduce variation while maintaining consistency with the general character of the surrounding area. In order to ensure consistency with the existing nature and character of the surrounding area, elements of the buildings should be revised to maintain the same general character of the development while introducing variation into the design. (3.18.3.D.) 14. For the final application provide architectural details of the railings and balusters, corner board trim, water table detail, shutter dog profile, and a wall section through the eave depicting the material configuration and dimensions and a revised Landscape Plan as the footprint configuration has changed. (Applications Manual) Approved with Conditions01/19/2021Beaufort Jasper Water and Sewer Review James Clardy Comments: 1. The project is under construction, pending issuance of the close-out and permit to operate. Approved with Conditions01/19/2021Building Safety Review Richard Spruce Comments: 1. For Type V construction, building walls located 10 feet or less from the property line must be 1 hour rated. Approved with Conditions01/19/2021HPRC Review Katie Peterson Comments: 01/19/2021 Page 2 of 3 ATTACHMENT 6 1. Service yards are to be located in a rear or side yard location not facing a street and away from all public vantage. As the service yard will be visible from a public vantage on all elevations, special consideration shall be given to the screening of the service yard. Additionally, provide location of electric meters. (5.15.5.10.) 2. A space under a sloping roof that has the line of intersection of the roof and the exterior wall supporting the roof not more than 3 feet above the floor level, and in which space the possible floor area with head room of 5 feet or more occupies between 30 and 70 percent of the total floor area of the story directly beneath. If the possible floor area with head room of 5 feet or more occupies more than 70 percent of the total floor area of the story directly beneath, then that space shall be considered a full story. The third story appears to have significant area which has possible floor area with head room of 5 feet or more which has not been included in the SF calculations. The square footage calculations will need to be updated to reflect this calculation. Additionally, there are discrepancies between the SF labels within the rooms, the narrative, and the leader line calculations (the coversheet is missing the numbers). While it is expected that the leader lines and room labels will vary slightly (interior vs exterior wall measurements), the room labels and leader line calculations exceed 70% of the floor beneath and would constitute a 3rd story. (5.15.5.F.1.e.) Approved01/19/2021Addressing Review Nick Walton Comments: 1. Address is 6 Marianna Way. Approved01/19/2021Transportation Department Review - HD William Howard Comments: 1. No comment. Approved01/19/2021Watershed Management Review William Baugher Comments: 1. See DPA-06-17-011010. Plan Review Case Notes: 01/19/2021 Page 3 of 3 ATTACHMENT 6

Source: Town of Bluffton website. First collected Oct 14, 2026.