Historic Preservation Review Commission (PDF)
Town of Bluffton · Beaufort County · meeting of Jan 6, 2021 · Agendas
Open the original document More from Town of Bluffton
Text
Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.
TOWN OF BLUFFTON
HISTORIC PRESERVATION COMMISSION
ELECTRONIC MEETING
Wednesday, January 6, 2021 6:00p.m.
This meeting can be viewed on the Town of Bluffton’s Facebook page
https://www.facebook.com/TownBlufftonSC/
I. CALL TO ORDER
II. ROLL CALL
III. NOTICE REGARDING ADJOURNMENT
The Historic Preservation Commission will not hear new items after 9:30
p.m. unless authorized by a majority vote of the Commission Members
present. Items which have not been heard before 9:30 p.m. may be
continued to the next regular meeting or a special meeting date as
determined by the Commission Members.
IV. NOTICE REGARDING PUBLIC COMMENTS*
Every member of the public who is recognized to speak shall address the
Chairman and in speaking, avoid disrespect to Commission, Staff, or other
members of the Meeting. State your name and address when speaking for
the record. COMMENTS ARE LIMITED TO THREE (3) MINUTES.
V. ADOPTION OF AGENDA
VI. ADOPTION OF MINUTES – December 2, 2020
VII. ELECTION OF OFFICERS – Election for vice-chair and Historic Preservation
Review Committee Member
VIII. PUBLIC COMMENTS FOR ITEMS NOT ON THE AGENDA*
IX. OLD BUSINESS
X. NEW BUSINESS
A. Certificate of Appropriateness: A request by Pearce Scott
Architects, on behalf of the owners Gerard and Beth Romski, for
approval of a Certificate of Appropriateness to allow the addition of
an 85 SF golf cart bay and 600 SF second story addition to the
Town of Bluffton
Historic Preservation Commission Agenda
January 6, 2021
Page 2
existing one-story 514 SF Carriage House located at 5806 Yaupon
Road, Lot 20A in the Stock Farm Development, in the Old Town
Bluffton Historic District and zoned Neighborhood General-HD.
(COFA-10-20-014698) (Staff – Katie Peterson)
B. Certificate of Appropriateness: A request by Pearce Scott
Architects, on behalf of the owner Kate Eagen, for approval of a
Certificate of Appropriateness to allow the construction of a 1.5-
story single-family residential structure of approximately 2,117 SF
and a 2-story Carriage House of approximately 1,172 SF located at
5718 Guilford Place, Lot 45 in the Stock Farm Development in the
Old Town Bluffton Historic District, and zoned Neighborhood
General-HD. (COFA-10-20-014673) (Staff – Katie Peterson)
C. Certificate of Appropriateness: A request by Webb Construction, on
behalf of the owner Ernie Suozzi, for approval of a Certificate of
Appropriateness to allow the construction of a 1.5-story single-
family residential structure of approximately 1,954 SF and a 1-story
Carriage House of approximately 352 SF located at 20 Meriwether
Court, Lot 3 in the Landen Oaks Development in the Old Town
Bluffton Historic District, and zoned Neighborhood General-HD.
(COFA-10-20-014694) (Staff – Katie Peterson)
XI. DISCUSSION
1. Discussion regarding large scale commercial development in Old Town
Bluffton Historic District (No Staff Report Attached).
XII. ADJOURNMENT
2. NEXT MEETING DATE– Wednesday, February 3, 2021
3.
* Public Comments may be submitted electronically via the Town’s website at
(https://bit.ly/TOBPublicComment ) or by emailing your comments to the Growth Management Coordinator at
dmclain@townofbluffton.com. Comments will be accepted up to 2 hours prior to the scheduled meeting start time.
All comments will be read aloud for the record and will be provided to the Historic Preservation Committee.
“FOIA Compliance – Public notification of this meeting has been published and posted in compliance with the
Freedom of Information Act and the Town of Bluffton policies.”
In accordance with the requirements of Title II of the Americans with Disabilities Act of 1990 ("ADA"), the Town
of Bluffton will not discriminate against qualified individuals with disabilities on the basis of disability in its
services, programs, or activities.
EXECUTIVE SESSION - The public body may vote to go into executive session for any item identified for action on the agenda.
Any person requiring further accommodation should contact the Town of Bluffton ADA Coordinator at
843.706.4500 or adacoordinator@townofbluffton.com as soon as possible but no later than 48 hours before the
scheduled event.
Town of Bluffton Historic Preservation Commission
Page 1 of 4
December 2, 2020
TOWN OF BLUFFTON HISTORIC PRESERVATION COMMISSION
Electronic Meeting
Wednesday, December 2, 2020, Minutes
Present: Bruce Trimbur - Chair; Will Guenther – Vice Chair; Courtney McNeil;
Michael Lovecchio; and, Jesse Solomon
Absent: Elaine Gallagher Adams
Staff: Katie Peterson, Senior Planner; Kevin Icard, Planning and Community
Development Manager; Charlotte Moore, Principal Planner; and, Darby
McLain, Growth Management Coordinator
I. CALL TO ORDER
Chairman Trimbur called the meeting to order at 6:04 p.m.
II. ROLL CALL
Commissioner Solomon was not present for the roll call but arrived at 6:08 p.m.
Commissioner Gallagher Adams was not in attendance.
III. NOTICE REGARDING ADJOURNMENT
The Historic Preservation Commission will not hear new items after 9:30 P.M.
unless authorized by a majority vote of the Commission Members present. Items
which have not been heard before 9:30 P.M. may be continued to the next regular
meeting or an additional meeting date as determined by the Commission members.
IV. NOTICE REGARDING PUBLIC COMMENTS
Every member of the public who is recognized to speak shall address the Chairman
and in speaking, avoid disrespect to the Commission, Town Staff, and other
members of the meeting. State your name and address when speaking for the
record. UNLESS OTHERWISE AMENDED BY THE HISTORIC PRESERVATION
COMMISSION, COMMENTS ARE LIMITED TO THREE (3) MINUTES.
V. ADOPTION OF THE AGENDA
Commissioner Guenther made a motion to adopt the agenda. Commissioner McNeil
seconded the motion. All were in favor and the motion passed. Commissioner
Solomon was not present.
VI. ADOPTION OF MINUTES
Town of Bluffton Historic Preservation Commission
Page 2 of 4
December 2, 2020
Commissioner McNeil made a motion to adopt the November 4, 2020 Minutes.
Commissioner Guenther seconded the motion. All were in favor the motion passed.
Commissioner Solomon was not present.
VII. ADOPTION OF 2021 MEETING DATES
Commissioner Guenther made a motion to adopt the 2021 meeting dates as
presented by Staff during the meeting. Commissioner Lovecchio seconded the
motion. All were in favor and the motion passed.
VIII. PUBLIC COMMENTS FOR ITEMS NOT ON THE AGENDA
There were no public comments.
IX. OLD BUSINESS
There was no old business.
X. NEW BUSINESS
A. Certificate of Appropriateness: A request by Christopher Epps of InCircle
Architecture, on behalf of the owners Trudy J. Eaton Trust, for approval of
a Certificate of Appropriateness to allow the addition of a 578 SF second
story addition to the existing one-story 514 SF Carriage House located at
23 Pritchard Street, Lot 1 in the Tabby Roads Development, in the Old Town
Bluffton Historic District and zoned Neighborhood General-HD. (COFA-09-
20-014597) (Staff – Katie Peterson)
Peterson presented the information to the Commission, which is
incorporated into these minutes.
Chris Epps, Applicant, spoke about the project and explained the approach
to the addition. Mr. Epps indicated that his client is in the process of getting
approval from the Tabby Roads Habitat and Architectural Review Board.
Commissioner Guenther stated that he liked the creativity of the project.
There were no other comments from the Commission.
Commissioner Guenther made a motion to approve the application with the
following condition:
1. Per the Applications Manual, the Application must be signed by the
Property Owner.
Commissioner Solomon seconded the Motion.
Commissioner McNeil made a motion to Amend the Primary Motion to
include that the letter of approval from Tabby Roads ARB be submitted to
The Town.
Town of Bluffton Historic Preservation Commission
Page 3 of 4
December 2, 2020
2. Prior to approval, a copy of the letter of approval from the Tabby Roads
ARB is required.
Commissioner Solomon seconded the motion to amend the Primary Motion.
All voted in favor to amend to the Primary Motion and the motion to amend
passed.
All voted in favor of Amended Primary Motion and the motion passed.
B. Certificate of Appropriateness - HD: A request by Pearce Scott Architects,
on behalf of the owners, Gerard and Beth Romski for approval of a
Certificate of Appropriateness to allow the addition of 120 SF outdoor
shower and a dog door on the exiting 2,849 SF single-family residence
located at 5806 Yaupon Road, Lot 20A in the Stock Farm Development, in
the Old Town Bluffton Historic District and zoned Neighborhood General-
HD. (COFA-09-20- 014957) (Staff – Katie Peterson)
Peterson presented the information to the Commission, which is
incorporated into these minutes.
Chairman Trimbur asked the Applicant, Sam Bielanin with Pearce Scott
Architects, if she had anything to add. She did not.
Commissioner Solomon asked about purpose of the roof configuration.
Bielani replied that as the shower area was smaller than the gabled roof
above, they chose a smaller shed roof rather than bring the full gabled roof
out. She indicated that roof will be metal. Commissioner Guenther said the
metal roof looks appropriate.
Commissioner McNeil made a motion to approve as submitted.
Commissioner Solomon seconded the motion. All were in favor and the
motion passed.
C. Certificate of Appropriateness - HD: A request by Dan Keefer for approval
of a Certificate of Appropriateness to allow the addition of a 396 SF carport
and storage area to the existing 577 SF Carriage House located at 5469
Mistletoe Loop, Lot 41 in the Stock Farm Development, in the Old Town
Bluffton Historic District and zoned Neighborhood General-HD. (COFA-10-
20-014675)(Staff – Katie Peterson)
Peterson presented the information to the Commission, which is
incorporated into these minutes.
Commissioner Solomon made a motion to approve the application as
submitted by the Applicant as the HPC found that in this case, the use of
the sliding barn doors on the courtyard side of the Carriage House was an
appropriate substitute for the door operations found in Section 5.15.6.I. of
Town of Bluffton Historic Preservation Commission
Page 4 of 4
December 2, 2020
the UDO. Commissioner McNeil seconded the motion. All were in favor and
the motion passed.
XI. DISCUSSION
1. Chairman Trimbur thanked Commissioner Guenther for his many years of
service on the Historic Preservation Commission and the Historic Preservation
Review Committee.
Peterson also thanked Commissioner Guenther for everything he put into the
HPC and said she hoped to continue to see him active in the Historic District.
Commissioner Guenther spoke on his time as a Commissioner and thanked both
staff and the other Commissioners for their work.
2. Discussion Regarding Building Size in Old Town Bluffton Historic District.
Moore presented several topics to be discussed in the future. The highlights
included:
Focus on Neighborhood Center Historic District
Mass and scale should fit into streetscape
Consider reducing the maximum building footprint in the NCE-HD
district to 2,000 – 2,500 sq. ft and the overall square footage to 4,500
sq. ft
Is there too much commercial development? How do we mitigate
impacts like traffic and parking?
Is it time to update the Old Town Master Plan (2006)?
What UDO Amendments would be needed to accomplish?
The Commissioners had multiple questions and concerns that the information
being presented had not been fully reviewed and felt that it was premature to
make any changes to the UDO at this time. Staff stated that they would present
their concerns to the UDO Administrator and would follow up with the
Commissioners at their next meeting.
XII. ADJOURNMENT
Commissioner Guenther made a motion to adjourn the December 2, 2020 Historic
Preservation Commission meeting. Commissioner McNeil seconded the motion, and
all were in favor. The meeting was adjourned at 7:38 p.m.
5806 Yaupon Road, Lot 20A– Certificate of Appropriateness Historic Preservation Commission
HISTORIC PRESERVATION
COMMISSION
STAFF REPORT
Department of Growth Management
MEETING DATE: January 6, 2021
PROJECT: 5806 Yaupon Road, Lot 20A– Carriage House
Addition
APPLICANT: Pearce Scott Architects
PROJECT MANAGER: Katie Peterson, AICP, Senior Planner
APPLICATION REQUEST: The Applicant, Pearce Scott Architects, on behalf of the
owners, Gerard and Beth Romski, requests that the Historic Preservation
Commission approve the following application:
1. COFA-10-20-014698. A Certificate of Appropriateness to allow the addition
of an 85 SF golf cart bay and 600 SF second story addition to the existing
one-story 514 SF Carriage House located at 5806 Yaupon Road, Lot 20A in
the Stock Farm Development, in the Old Town Bluffton Historic District and
zoned Neighborhood General-HD.
INTRODUCTION: The Applicant is proposing the construction of an 85 SF golfcart
bay and 600 SF second story addition the existing primary Carriage House located
at 5806 Yaupon Road in the Old Town Bluffton Historic District. The single-family
residence and Carriage House were originally reviewed and approved by the
Historic Preservation Commission at the May 6, 2015 HPC meeting (COFA-03-15-
009157). The proposed addition would expand the existing 15 SF bump-out to
create a golf cart bay on the first floor, remove the roof of the existing Carriage
House, and add a second story directly on top. The materials would be a
continuation of the existing structure, and the roof shape and pitch would remain
the same. The bracketed shed roof over the garage doors, which was approved in
2015, but not constructed would be installed at this time.
This project was presented to the Historic Preservation Review Committee for
conceptual review at the October 16, 2020 meeting and comments were provided
to the Applicant (See Attachment 5).
HISTORIC PRESERVATION COMMISSION ACTIONS: As granted by the powers and
duties set forth in Section 2.2.6.E.2, the Historic Preservation Commission has the
authority to take the following actions with respect to this application:
1. Approve the application as submitted by the Applicant;
2. Approve the application with conditions; or
January 6, 2021 Page 2
5806 Yaupon Road, Lot 20A – Certificate of Appropriateness Historic Preservation Commission
3. Deny the application as submitted by the applicant.
It is important to note that the intent of Section 5.15 Old Town Bluffton Historic
District of the Unified Development Ordinance (UDO), is that the Section be user
friendly and informative to the residents and the members of HPC and is not
intended to discourage creativity or force the replication of historic models. Rather,
it is to set forth a framework in which the diversity that has always characterized
Bluffton can continue to grow. The Section also defines guidelines for design and
materials similar to that used on structures within the Old Town, and it is the
charge of the HPC to assess the interpretation of these guidelines as they pertain to
applications using the established review criteria.
REVIEW CRITERIA & ANALYSIS: Town Staff and the Historic Preservation
Commission are required to consider the criteria set forth in Section 3.18.3 of the
UDO in assessing an application for a Certificate of Appropriateness – Historic
District (HD). The applicable criteria are provided below followed by a Staff
Finding(s) based upon review of the application submittals to date.
1. Section 3.18.3.B. Consistency with the principles set forth in the Old Town
Master Plan.
a. Finding. The application is consistent with the principles set forth in the
Old Town Master Plan. The Old Town Master Plan states that, “The built
environment, in particular the historic structures scattered throughout Old
Town, should be protected and enhanced. While it is of great importance
to save and restore historic structures, it is just as important to add to the
built environment in a way that makes Old Town more complete.”
The Applicant proposes an addition to an existing Carriage House
structure within the Old Town Bluffton Historic District, a locally and
nationally designated historic district. The addition, with the conditions
met found in Item 2 of this Section, has been designed to be sympathetic
to the architectural character of the neighboring historic structures, so its
addition to the architectural diorama will both protect the integrity of the
existing historic structures and enhance the neighborhood by adding
architectural variety.
b. Finding. The Old Town Master Plan initiatives also include the adoption of
a form-based code that included architectural standards for structures
located within the Old Town Bluffton Historic District. These standards
are included in Article 5 of the Unified Development Ordinance. The
addition proposed as part of this request will be in conformance with
those standards if the conditions noted in Item 2 of this Section are met.
c. Finding. The Old Town Master Plan initiatives also promote preservation
and protection of the legacy of the Old Town Bluffton Historic District
through additions to the built environment which make Old Town more
complete. The proposed addition will continue to provide completeness to
the neighborhood and overall district.
January 6, 2021 Page 3
5806 Yaupon Road, Lot 20A – Certificate of Appropriateness Historic Preservation Commission
2. Section 3.18.3.C. The application must be in conformance with applicable
provisions provided in Article 5, Design Standards.
a. Finding. Town Staff finds that the proposed addition will be in
conformance with the applicable provisions provided in Article 5.
3. Section 3.18.3.D. The nature and character of the surrounding area and
consistency of the structure with the harmony of the surrounding
neighborhood.
Finding. Town Staff finds that nature and character of the addition to the
existing structure is consistent and harmonious with that of the surrounding
neighborhood. The mass and scale of the addition is appropriate for its
location and the architectural detailing is sensitive to the neighboring
properties.
4. Section 3.18.3.F. The historic, architectural, and aesthetic features of the
structure including the extent to which its alteration or removal would be
detrimental to the public interest.
Finding. The Applicant seeks approval for the addition to a Carriage House
on a single-family residential lot built in 2015 in the Old Town Bluffton
Historic District. The proposed plans are sympathetic in design to the
neighboring historic and non-historic resources; therefore, the addition, as
proposed, will have no adverse effect on the public interest.
5. Section 3.18.3.H. The application must comply with applicable requirements
in the Applications Manual.
Finding. The Certificate of Appropriateness Application has been reviewed
by Town Staff and has been determined to be complete.
STAFF RECOMMENDATION: It is the charge of the HPC to assess and interpret the
standards and guidelines set forth in the UDO as they pertain to applications using
the review criteria established in the UDO and to take appropriate action as granted
by the powers and duties set forth in Section 2.2.6.E.2. Town Staff finds the
requirements of Section 3.18.3 of the Unified Development Ordinance have been
met and recommends that the Historic Preservation Commission approve the
application as submitted.
ATTACHMENTS:
1. Location Map
2. Zoning Map
3. Applicant Narrative
4. Application and Plans
5. HPRC Comments
6. HOA Approval
5806 Yaupon Road, Lot 20A: Location Map
1 2 / 2 1 / 2 0 2 0
0 0 . 0 3 0 . 0 5 0 . 0 8 0 . 1 0 . 1 30 . 0 1
m i
F
ATTACHMENT 1
5806 Yaupon Road, Lot 20A: Zoning Map
1 2 / 2 1 / 2 0 2 0
0 0 . 0 3 0 . 0 5 0 . 0 8 0 . 1 0 . 1 30 . 0 1
m i
F
O v e r r id e 1
P a r c e l P r o p e r t y L in e s
ATTACHMENT 2
TOWN OF BLUFFTON
CERTIFICATE OF APPROPRIATENESS- OLD TOWN BLUFFTON
HISTORIC DISTRICT (HD) APPLICATION
Town of Bluffton Certificate of Appropriateness-Historic District Application Last Updated: 4/8/2014
Growth Management Customer Service Center
20 Bridge Street
Bluffton, SC 29910
(843)706-4522
www.townofbluffton.sc.gov
applicationfeedback@townofbluffton.com
Applicant Property Owner
Name: Name:
Phone: Phone:
Mailing Address: Mailing Address:
E-mail: E-mail:
Town Business License # (if applicable):
Project Information (tax map info available at http://www.townofbluffton.us/gis/)
Project Name: Conceptual: Final: Amendment:
Project Location: Application for:
New Construction
Renovation/Rehabilitation/Addition
Relocation or Demolition
Zoning District:
Acreage:
Tax Map Number(s):
Project Description:
Minimum Requirements for Submittal
1. Full sized copies and digital files of the Site Plan(s). One (1) set for Conceptual, two (2) sets for Final
2. Full sized copies and digital files of the Architectural Plan(s). One (1) set for Conceptual, two (2) sets for Final
3. Project Narrative describing reason for application and compliance with the criteri a in Article 3 of the UDO.
5. All information required on the attached Application Checklist.
6. An Application Review Fee as determined by the Town of Bluffton Master Fee Schedule. Checks made payable
to the Town of Bluffton.
Note: A Pre-Application Meeting is required prior to Application submittal.
Disclaimer: The Town of Bluffton assumes no legal or financial liability to the applicant or any
third party whatsoever by approving the plans associated with this permit.
I hereby acknowledge by my signature below that the foregoing application is complete and accurate and that I am
the owner of the subject property. As applicable, I authorize the subject property to be posted and inspected.
Property Owner Signature: Date:
Applicant Signature: Date:
For Office Use
Application Number: Date Received:
Received By: Date Approved:
ATTACHMENT 3
TOWN OF BLUFFTON
CERTIFICATE OF APPROPRIATENESS – HISTORIC DISTRICT
PROJECT ANALYSIS
Last Updated: 4/8/2014
In accordance with the Town of Bluffton Unified Development Ordinance (UDO), the following information shall
be included as part of a Certificate of Appropriateness application submitted for review by the Historic
Preservation Commission (HPC) and the Historic Preservation Review Committee . The use of this checklist by
Town Staff or the Applicant shall not constitute a waiver of any requirement contained in the UDO.
1. DESIGN REVIEW PHASE CONCEPTUAL REVIEW FINAL REVIEW
2. SITE DATA
Identification of Proposed Building Type (as defined in Article 5):
Building Setbacks Front: Rear: Rt. Side: Lt. Side:
3. BUILDING DATA
Building
Description
(Main House, Garage, Carriage
House, etc.)
Existing Square
Footage
Proposed Square
Footage
Main Structure
Ancillary
Ancillary
4. SITE COVERAGE
Impervious Coverage Coverage (SF)
Building Footprint(s)
Impervious Drive, Walks & Paths
Open/Covered Patios
A.TOTAL IMPERVIOUS COVERAGE
B.TOTAL SF OF LOT
% COVERAGE OF LOT (A/B= %)
5. BUILDING MATERIALS
Building Element Materials, Dimensions,
and Operation Building Element Materials, Dimensions,
and Operation
Foundation Columns
Walls Windows
Roof Doors
Chimney Shutters
Trim Skirting/Underpinning
Water table Cornice, Soffit, Frieze
Corner board Gutters
Railings Garage Doors
Balusters
Green/Recycled Materials
Handrails
ATTACHMENT 3
TOWN OF BLUFFTON
CERTIFICATE OF APPROPRIATENESS – HISTORIC DISTRICT
APPLICATION CHECKLIST
Town of Bluffton Applications Manual 2 of 3 Last Updated: 4/8/2014
Note: Certificate of Appropriateness application information will vary depending on the activities proposed.
At a minimum, the following items (signified by a grayed checkbox) are required, as applicable to the
proposed project.
Concept Final BACKGROUND INFORMATION.
COMPLETED CEFTIFICATE OF APPROPRIATENESS-HD APPLICATION: A
competed and signed application providing general project and contact information.
PROPERTY OWNER CONSENT: If the applicant is not the property owner, a letter of
agency from the property owner is required to authorize the applicant to act on behalf of
the property owner.
PROJECT NARRATIVE: A detailed narrative describing the existing site conditions and
use, the proposed development intent with proposed uses and activities that will be
conducted on the site. Include a description of the proposed building type and proposed
building materials as permitted in Article 5.
DEED COVENANTS/RESTRICTIONS: A copy of any existing deed covenants,
conditions and restrictions, including any design or architectural standards that apply to
the site.
ADDITIONAL APPROVALS: A written statement from the Declarant of any deed
covenants, conditions, or restrictions and/or the Review Body of any design or
architectural standards that the current design has been reviewed for consistency with the
established restrictions/design principles and approved.
Concept Final SITE ASSESSMENT.
LOCATION MAP: Indicating the location of the lot and/or building within the Old Town
Bluffton Historic District with a vicinity map.
PROPERTY SURVEY: Prepared and sealed by a Registered Land Surveyor indicating the
following, but not limited to:
All property boundaries, acreage, location of property markers, name of county, municipality,
project location, and parcel identification number(s);
Municipal limits or county lines, zoning, overlay or special district boundaries, if they traverse
the tract, form a part of the boundary of the tract, or are contiguous to such boundary;
All easements of record, existing utilities, other legal encumbrances, public and private
rights-of-way, recorded roadways, alleys, reservations, and railways;
Existing watercourses, drainage structures, ditches, one-hundred (100) year flood elevation,
OCRM critical line, wetlands or riparian corridors top of bank locations, and protected lands
on or adjacent to the property;
Location of existing buildings, structures, parking lots, impervious areas, public and private
infrastructure, or other man-made objects located on the development property; and
North arrow, graphic scale, and legend identifying all symbology.
SITE PLAN: Showing layout and design indicating, but not limited to:
All property survey information showing all building footprint(s) with finish floor elevations,
setbacks and build-to lines, building location(s), building orientation(s);
Overall lot configuration depicting ingress/egress, circulation, driveways, parking areas,
patios, decks, pools, hardscape, service yards and all other site amenities;
Pedestrian circulation elements and ensuring design shows ADA accessibility compliance.
Location, layout, and number of vehicular and bicycle parking spaces bicycle parking, and
ensuring design shows ADA accessibility compliance; and
Include detailed dimensions as necessary and appropriate to demonstrate compliance with
all applicable standards and requirements.
ATTACHMENT 3
TOWN OF BLUFFTON
CERTIFICATE OF APPROPRIATENESS – HISTORIC DISTRICT
APPLICATION CHECKLIST
Town of Bluffton Applications Manual 3 of 3 Last Updated: 4/8/2014
SIGN AND RETURN THIS CHECKLIST WITH THE APPLICATION SUBMITTAL
ALL SUBMITTALS MUST BE COLLATED AND FOLDED TO 8-1/2” X 11”
By signature below I certify that I have reviewed and provided the submittal items listed above . Further, I
understand that failure to provide a complete, quality application or erroneous information may result in the delay
of processing my application(s).
______________________________________________________ _______________________
Signature of Property Owner or Authorized Agent Date
______________________________________________________
Printed Name
PHOTOS: Comprehensive color photograph documentation of the property, all exterior
facades, and the features impacted by the proposed work. If digital, images should be at
a minimum of 300 dpi resolution.
Concept Final ARCHITECTURAL INFORMATION.
CONCEPTUAL ARCHITECTURAL SKETCHES : Sketch of plans, elevations, details,
renderings, and/or additional product information to relay design intent.
FLOOR/ROOF PLANS : Illustrate the roof and floor plan configurations. Include all
proposed uses, walls, door & window locations, overall dimensions and square footage(s).
ELEVATIONS: Provide scaled and dimensioned drawings to i llustrate the exterior
appearance of all sides of the building(s). Describe all exterior materials and finishes and
include all building height(s) and heights of appurtenance(s) as they relates to adjacent
grade, first floor finished floor elevations, floor to ceil ing height for all stories, existing and
finish grades for each elevation.
ARCHITECTURAL DETAILS : Provide scaled and dimensioned drawings to show the
configuration and operation of all doors, windows, shutters as well as the configuration
and dimensional information for columns and porch posts, corner boards, water tables,
cupolas and roof appurtenances, gutters and downspouts, awnings, marquees, balconi es,
colonnades, arcades, stairs, porches, stoops and railings.
MANUFACTURER’S CUT SHEET/SPECIFICATIONS : Include for all atypical building
elements and materials not expressly permitted by Article 5 of the UDO with sizes and
finishes noted.
Concept Final LANDSCAPE INFORMATION.
TREE REMOVAL PLAN: A site plan indicating location, species, and caliper of existing
trees and trees to be removed.
LANDSCAPE PLAN: Plan must include proposed plant materials including names,
quantities, sizes and location, trees to be removed/preserved/relocated, areas of planting,
water features, extent of lawns, and areas to be vegetated. Plant key and list to be
shown on the lan dscape plan as well as existing and proposed canopy coverage
calculations.
Concept Final ADDITIONAL REQUIRED INFORMATION (Single-Family Residential Excluded).
PRELIMINARY DEVELOPMENT PLAN APPLICATION: Submit a Preliminary
Development Plan Application along with all required submittal items as depicted on the
application checklist.
ATTACHMENT 3
December 04, 2020
Lot 20A Stock Farm Narrative
On behalf of the owner, we would like to propose a new golf cart addition and second
floor to the existing Garage. All details and materials will match existing and follow
the UDO requirements.
The windows on the existing garage will be relocated on the new addition. The
covered connector will remain and is not in this scope of work.
Please find attached drawings and the main house existing photos in this submittal.
Thank you for your consideration,
Amanda Jackson Denmark
Project Manager
ATTACHMENT 3
ATTACHMENT 3
ATTACHMENT 3
ATTACHMENT 3
Existing
ATTACHMENT 4
Existing
ATTACHMENT 4
Existing
ATTACHMENT 4
EXISTING
GARAGE
EXISTING
MAIN HOUSE PROPOSED
ADDITION
1/8" = 1'-0"
SITE PLAN
1
CH001
SITE PLAN
N
© 2020 PEARCE SCOTT ARCHITECTS
PEARCE
SCOTT
ARCHITECTS
6 STATE OF MIND ST
SUITE 200
BLUFFTON, SC 29910
843.837.5700
RENOVATION FOR:
GERARD & BETH ROMSKI
LOT 20A, 5806 YAUPON ROAD
STOCK FARM
BLUFFTON, SC 29910
DESCRIPTION / REVISION LOGNO. INITIALDATE
PROJECT NO. 2075
DATE 10.20.20
DRAWN BY SDB
CHECKED BY AWB
SHEET NO.
DO NOT SCALE FROM DRAWINGSNOT FOR CONSTRUCTION
24X36 PAPER SIZE
CONCEPTUAL HPC SUBMITTAL AJD10.20.20
FINAL HPC SUBMITTAL - CH AJD11.03.20
ATTACHMENT 4
32'-0"
6'-0" 5'-312" 6'-0"
30" REF.
SLOPEDSLOPED
SLOPEDSLOPED
EXISTING
CONNECTOR
ROOF
BELOW
7'-0" VANITY
11'-6" 5'-3"5'-3"
10'-0"
24" X 28"
STACKED
W/D
D/W
R&S
LIVING SPACE
002
CLOSET
004
BEDROOM
003
BATH
005
22'-0"
4'-9" 6'-612" 5'-1112" 4'-9"
EXISTING
DH WINDOW
5'-9" 5'-9"
EXISTING
CA WINDOW
10'-0"
22'-0"
5'-0" 5'-0"
22'-0"
11'-0"
002A
005A
003A
004A
B B
A
B
3'-612" 7'-512"
4'-812"
1
COUNTERTOP WITH
BRACKETS FOR SEATING
1
CH301
1
CH301
2
CH201
1
CH201
3
CH201
4
CH201
1
CH401
CL
3'-11"
DN
3
3
FLAT CEILING
5'-3"5'-3"5'-3"
10'-0"
22'-0"
11'-6"
EXISTING
CONNECTOR
EXISTING
GARAGE
REMOVE EXISTING ROOF AND CEILING
STRUCTURE AND PREP FOR NEW
SECOND FLOOR ADDITION
CART BAY
001
EXISTING
DH WINDOW
10'-0"
5'-0" 5'-0"
5'-9" 5'-9"
EXISTING
CA WINDOWS
EXISTING
DOOR
EXISTING
DOOR
EXISTING
DOOR
001A
5'-0" 5'-0"
2
2
1
CH301
1
CH301
2
CH201
1
CH201
3
CH201
4
CH201 4'-6"
4'-6"
UP
1
CH401
3
7'-0"
2'-6"11'-6"8'-0"
SERVICE YARD
10X10 POST8X8 POST
AREA CALCULATIONS
CONDITIONED SPACE:
SECOND FLOOR
UNCONDITIONED SPACE:
GARAGE
OVERALL TOTAL
599
599
1,198
LEGEND
R&S: ROD AND SHELF
: CENTERLINE
1. 18 RISERS @ +/- 7 1/2", 17 TREADS @ 11" EA.
2. REMOVE EXISTING WINDOW AND INFILL WITH NEW
WALL TO MATCH EXISTING
3. RELOCATED WINDOW
PROJECT NOTES
GENERAL NOTES
A. ALL SECOND FLOOR INTERIOR WALLS TO
BE 2X6 UNLESS OTHERWISE NOTED.
B. ALL INTERIOR DOORS TO BE 6" OFF OF
ADJACENT STUD WALL UNLESS
OTHERWISE NOTED
C. ALL FIRST FLOOR CEILING HEIGHTS TO
BE 9'-6" UNLESS OTHERWISE NOTED
D. ALL SECOND FLOOR CEILING HEIGHTS TO
BE 8'-0" UNLESS 0THERWISE NOTED
E. ALL WINDOWS AND DOORS MEASURED
TO THE CENTERLINE
F. ALL EXTERIOR WINDOW MULLS TO BE 4"
UNLESS OTHERWISE NOTED
NEW FRAMING
EXISTING FRAMING
- BEFORE COMMENCING WORK, THE
CONTRACTOR SHALL FILE ALL REQUIRED
CERTIFICATES OF INSURANCE WITH THE
DEPARTMENT OF BUILDINGS, OBTAIN ALL
REQUIRED PERMITS, AND PAY ALL FEES
REQUIRED BY BEAUFORT COUNTY.
- THE CONTRACTOR SHALL VERIFY ALL
EXISTING CONDITIONS IN THE FIELD PRIOR TO
COMMENCING WORK, AND SHALL REPORT ANY
DISCREPANCIES BETWEEN DRAWINGS AND
FIELD CONDITIONS TO THE ARCHITECT.
- THE CONTRACTOR IS NOT TO SCALE
DRAWINGS OR DETAILS. ONLY WRITTEN
DIMENSIONS ARE TO BE USED.
- MINOR DETAILS NOT USUALLY SHOWN OR
SPECIFIED, BUT NECESSARY FOR PROPER
CONSTRUCTION OF ANY PART OF THE WORK
SHALL BE INCLUDED AS IF THEY WERE
INDICATED IN THE DRAWINGS.
- THE CONTRACTOR SHALL COORDINATE ALL
WORK PROCEDURES WITH REQUIREMENTS OF
LOCAL AUTHORITIES.
- THE CONTRACTOR SHALL BE RESPONSIBLE
FOR THE PROTECTION OF ALL CONDITIONS AND
MATERIALS WITHIN THE PROPOSED
CONSTRUCTION AREA. THE CONTRACTOR
SHALL DESIGN AND INSTALL ADEQUATE
SHORING AND BRACING FOR ALL STRUCTURAL
OR REMOVAL TASKS. THE CONTRACTOR
SHALL HAVE SOLE RESPONSIBILITY FOR ANY
DAMAGE OR INJURIES CAUSED BY OR DURING
THE EXECUTION OF THE WORK.
- EACH CONTRACTOR SHALL LAY OUT HIS OWN
WORK, AND SHALL PROVIDE ALL DIMENSIONS
REQUIRED FOR OTHER CONTRACTORS
(PLUMBING, ELECTRICAL, MECH).
- PLUMBING, MECHANICAL AND ELECTRICAL
WORK SHALL BE PERFORMED BY PERSONS
LICENSED IN THEIR TRADES, WHO SHALL
ARRANGE FOR AND OBTAIN INSPECTIONS AND
REQUIRED SIGN-OFFS.
- EACH CONTRACTOR SHALL DO CUTTING,
PATCHING, REPAIRING AS REQUIRED TO
PERFORM ALL OF THE WORK INDICATED ON
THE DRAWINGS, AND ALL OTHER WORK THAT
MAY BE REQUIRED TO COMPLETE THE JOB IN
EACH PRIME CONTRACT.
- EACH CONTRACTOR SHALL COORDINATE HIS
WORK WITH THAT OF THE OTHER
CONTRACTORS AND SUPPLIERS.
DEMO GENERAL NOTES
DOORS
001A
002A
003A
004A
005A
WINDOWS
A
B
NOTE: ALL HEAD, JAMB AND SILL
DETAILS TO MATCH EXISTING
WINDOW/DOOR SCHEDULE
6'-0" X 8'-0" OVERHEAD DOOR, MATCH EXISTING
3'-0" X 6'-8" 4 LITE, 1 PANEL (2/3 LITE)
2'-10" X 6'-9" BARN DOOR (2'-8" X 6'-8" C.O.)
2'-4" X 6'-8" POCKET DOOR
2'-4" X 6'-8" INTERIOR DOOR
2'-8" X 3'-6" CASEMENT, MATCH EXISTING
2'-8" X 5'-0" CASEMENT, MATCH EXISING
CL
EXISTING
CONNECTOR
BELOW
6:12
SLOPE
RIDGE RIDGE
1'-0"
2'-0"
1'-0"
2'-0"
6:12
SLOPE
6:12
SLOPE6:12
SLOPE
4:12
SLOPE
4"
2'-0"
1
CH301
1
CH301
2
CH201
1
CH201
3
CH201
4
CH201
2'-5"
METAL ROOF
MATCH EXISTING
LINE OF SECOND FLOOR BELOW
ROOF BRACKETS BELOW
10'-0"
+/- 5'-3"11'-6"+/- 5'-3"
10'-0"
EXISTING GARAGE FOUNDATION
SLOPE TO
DRAIN
TOP OF SLAB
6" A. FIN. GRADE
MATCH EXISTING
+/- 3'-0"
EXISTING
7'-0"
+/- 3'-0"
EXISTING
7'-0"
1
CH301
1
CH301
19'-6" +/- 2'-6"
3'-10"
BITUMINOUS
EXPANSION FILLER
NOTE: TIE NEW SLAB IN
TO EXISTING SLAB
11'-6"8'-0"
TOP OF SLAB
4" A. FIN. GRADE
LINE OF POST
ABOVE
1.
2.
FOUNDATION NOTES:
ARCHITECTURAL FOUNDATION FOR
EXTERIOR DIMENSIONS & LEVEL CHANGES
ONLY. REFER TO STRUCTURAL FOR ALL
OTHER INFORMATION.
CONTACT ARCHITECT IF MATERIALS
CHANGE, AS THIS WILL AFFECT FINISHED
FLOOR TO FINISHED FLOOR LEVEL
CHANGES.
REFER TO STRUCTURAL FOUNDATION
PLAN FOR CONTROL JOINT LOCATIONS
AND FOOTING SIZES AND DETAILS.
3.
CONTRACTOR TO COORDINATE ALL FIRST
FLOOR PLUMBING PRIOR TO SLAB POUR.
4.
5. ALL HARDSCAPE / PAVING, PADS, FILL &
GRADING TO BE COORD. BY CONTRACTOR
& LANDSCAPE ARCHITECT
1/4" = 1'-0"
SECOND FLOOR PLAN
2
CH101
C.H. PLANS
1/4" = 1'-0"
FIRST FLOOR PLAN
1
1/4" = 1'-0"
ROOF PLAN
4
1/4" = 1'-0"
FOUNDATION PLAN
3
© 2020 PEARCE SCOTT ARCHITECTS
PEARCE
SCOTT
ARCHITECTS
6 STATE OF MIND ST
SUITE 200
BLUFFTON, SC 29910
843.837.5700
RENOVATION FOR:
GERARD & BETH ROMSKI
LOT 20A, 5806 YAUPON ROAD
STOCK FARM
BLUFFTON, SC 29910
DESCRIPTION / REVISION LOGNO. INITIALDATE
PROJECT NO. 2075
DATE 10.20.20
DRAWN BY SDB
CHECKED BY AWB
SHEET NO.
DO NOT SCALE FROM DRAWINGSNOT FOR CONSTRUCTION
24X36 PAPER SIZE
CONCEPTUAL HPC SUBMITTAL AJD10.20.20
FINAL HPC SUBMITTAL - CH AJD11.03.20
ATTACHMENT 4
412
HORIZONTAL LAP
SIDING TO MATCH
EXISTING
SHAKE SIDING
TO MATCH
EXISTING
12
6
EXISTING CONNECTOR
6"
GRADE
T.O. SLAB @ GARAGE
T.O. SUBFLOOR
T.O. PLATE
T.O. EXISTING DOOR
8'-0"
10'-111 4" 8'-11 4"
6'-83 4"
T.O. WINDOW
B
6"
GRADE
T.O. SLAB @ GARAGE
T.O. SUBFLOOR
T.O. DOOR
8'-0"
10'-111 4" 6'-83 4"
T.O. WINDOW
B B A
1
CH301
HORIZONTAL LAP
SIDING TO MATCH
EXISTING
METAL ROOF
TO MATCH
EXISTING
CLOSED SOFFIT
TO MATCH
EXISTING
WOOD HANDRAILS
& STEPS
6"
GRADE
T.O. SLAB @ GARAGE
T.O. SUBFLOOR
T.O. DOOR
8'-0"
10'-111 4" 6'-83 4"
T.O. WINDOW
EXISTING
WINDOW
EXISTING
WINDOW
5'-0"
TO BE REUSED/
RELOCATED
TO BE REUSED/
RELOCATED
1
CH301
SERVICE YARD UNDER STAIR
MATCH EXISTING
6"
GRADE
T.O. SLAB @ GARAGE
T.O. SUBFLOOR
T.O. PLATE
T.O. WINDOW
8'-0"
10'-111 4" 8'-11 4"
6'-83 4"
T.O. WINDOW
12
6
4 12
EXISTING
WINDOW
EXISTING
WINDOW
EXISTING
WINDOW
1
CH401
9'-1012"
B.O. BEAM
3
CH301
TO BE REUSED/
RELOCATED
TO BE REUSED/
RELOCATED
1/4" = 1'-0"
FRONT ELEVATION
1
1/4" = 1'-0"
REAR ELEVATION
2
CH201
C.H.
ELEVATIONS
© 2020 PEARCE SCOTT ARCHITECTS
PEARCE
SCOTT
ARCHITECTS
6 STATE OF MIND ST
SUITE 200
BLUFFTON, SC 29910
843.837.5700
RENOVATION FOR:
GERARD & BETH ROMSKI
LOT 20A, 5806 YAUPON ROAD
STOCK FARM
BLUFFTON, SC 29910
DESCRIPTION / REVISION LOGNO. INITIALDATE
PROJECT NO. 2075
DATE 10.20.20
DRAWN BY SDB
CHECKED BY AWB
SHEET NO.
DO NOT SCALE FROM DRAWINGSNOT FOR CONSTRUCTION
24X36 PAPER SIZE
CONCEPTUAL HPC SUBMITTAL AJD10.20.20
FINAL HPC SUBMITTAL - CH AJD11.03.20
1/4" = 1'-0"
RIGHT ELEVATION
4
1/4" = 1'-0"
LEFT ELEVATION
3
ATTACHMENT 4
8'-0"
13'-31 4"9'-6"
EXISTING GARAGE
CART BAY BEYOND
LIVING SPACE
002
CLOSET
004
VAULTED SPACE
BEYOND
12
6
TYPE 'X' GYP.
2X8 CEILING FRAMING
2X8 ROOF FRAMING
WOOD CASING,
MATCH EXISTING
3 1/2"
5 1/2"
1" SQUARE
WOOD PICKETS
4X4 P.T. NEWEL
POST W/ CAP
5/4 X TREADS
& RISERS
1" SQUARE
WOOD PICKETS
P.T. 1x4
P.T. 2X4 TOP RAIL,
DOUBLE SLOPED TOP
P.T. 1x BOTTOM
RAIL
2" 5" 1" 2 1/2"2'-3 1/2"
P.T. 2X4 TOP RAIL,
DOUBLE SLOPED TOP
3 3/4"
3'-0"
+/- 6"
1" 10"
6"
3'-0"
4
12
2'-6"
5 1/2"
2'-2 1/2" 5 1/2"6"
4"
1'-8"
3"
4"
2"
BRACKET ELEVATION
HURRICANE CLIP @
EA. RAFTER
2X8 RAFTERS @ 16" O.C.,
SEE STRUCTURAL
METAL ROOF
MATCH EXISTING
EXTERIOR ROOF SHEATHING
6X6 BEAM
3
4" DIA. LAG SCREWS
(MIN. 4" PEN. IN TO
BLOCKING),
PLUG WITH LIKE WOOD
(2) 2X BLOCKING
@ EA. BRACKET
P.T. 2X6 VERTICAL
WALL SUPPORT @ EA. BRACKET
P.T. 6X6
BRACKET
5
8" DIA. GALV. THRU BOLT
(COUNTERSINK)
1
2" DIA. LAG SCREW
(MIN. 2.5" PEN. INTO 6X6),
PLUG WITH LIKE WOOD
P.T. 6X6
1
2" DIA. LAG SCREW
(MIN. 2.5" PEN.)
(2) 2X BLOCKING
@ EA. BRACKET
2'-0"
45° 5 1/2" 5 1/2"
3 1/2"
THRU WALL FLASHING
3'-2"
COUNTER FLASHING
2X BLOCKING AS
REQUIRED
2X6 LEDGER BOARD
1X4
2X FRIEZE
SIDING -
SEE ELEVATION
2 1/2"
THRU WALL FLASHING
METAL
DRIP EDGE
2X8
1X4 TRIM
1X8 TRIM
INTERIOR FLOOR FINISH
P.T. SHIM
DOOR, SEE SCHEDULE
2X FLOOR FRAMING,
SEE STRUCTURAL
P.T. WOOD SILL
METAL PAN FLASHING W/
END DAMS
STAIR FRAMING,
SEE STRUCTURAL
WOOD DECKING
SLOPE TO DRAIN
3"
3"
13
4" 1
2"
CH301
BUILDING
SECTION &
DETAILS
1" = 1'-0"
WINDOW TRIM
2
1/4" = 1'-0"
BUILDING SECTION
1
© 2020 PEARCE SCOTT ARCHITECTS
PEARCE
SCOTT
ARCHITECTS
6 STATE OF MIND ST
SUITE 200
BLUFFTON, SC 29910
843.837.5700
RENOVATION FOR:
GERARD & BETH ROMSKI
LOT 20A, 5806 YAUPON ROAD
STOCK FARM
BLUFFTON, SC 29910
DESCRIPTION / REVISION LOGNO. INITIALDATE
PROJECT NO. 2075
DATE 10.20.20
DRAWN BY SDB
CHECKED BY AWB
SHEET NO.
DO NOT SCALE FROM DRAWINGSNOT FOR CONSTRUCTION
24X36 PAPER SIZE
CONCEPTUAL HPC SUBMITTAL AJD10.20.20
FINAL HPC SUBMITTAL - CH AJD11.03.20
1" = 1'-0"
RAILING DETAIL
4
1" = 1'-0"
BRACKET DETAIL
33" = 1'-0"
DOOR SILL, TYP.
5
ATTACHMENT 4
3
CH401
6"
GRADE
T.O. SLAB @ GARAGE
9'-6"
T.O. SUBFLOOR
10'-11 1/4" 8'-1 1/4"
16" FLOOR SYSTEM
TYPE 'X' GYP. BOARD
T.O. PLATE
6
12
2
CH401
2X6 STUD WALL @ 16" O.C.
W/ THERMAL INSULATION
MOISTURE BARRIER
OVER 1/2" EXTERIOR SHEATHING
HURRICANE CLIP @
EA. RAFTER
2X RAFTERS @ 16" O.C.,
SEE STRUCTURAL
METAL
DRIP EDGE
2X8
1X4 HARDIE SOFFIT
SPRAY FOAM INSULATION
AT ALL ROOFS, TYP.
1X4 TRIM
1X8 TRIM
SIDING, MATCH EXISTING
STANDING SEAM METAL ROOF
MATCH EXISTING
NOTE: PER CODE, RAFTER
NOTCH CANNOT EXCEED
25% DEPTH OF RAFTER
ICE & WATER SHIELD OVER
ROOF SHEATHING
(2) 2X6 TOP PLATE
INTERIOR WALL FINISH
6
12
2'-0"
1 2"
P.T. 2X10 HARDIE TRIM
BOTTOM OF TRIM TO ACT AS WINDOW HEAD TRIM
P.T. 2X2 (ACTUAL)
HARDIE TRIM
MOISTURE BARRIER
OVER 1/2" EXTERIOR SHEATHING
ANCHOR BOLT PER
STRUCTURAL
BLOCKING AS REQ'D FOR TRIM
INTERIOR WALL FINISH
P.T. STARTER STRIP
FOUNDATION,
SEE STRUCTURAL
GRADE - SLOPE TO DRAIN
P.T. 2X6 BASE PLATE
+/- 6"
CONTINUOUS METAL FLASHING, LAP
MOISTURE BARRIER OVER FLASHING
EXTEND UP WALL MIN. 16"
SIDING, MATCH EXISTING
2X6 STUD WALL @ 16" O.C.
1 1/2" = 1'-0"
FOUNDATION DETAIL
3 1" = 1'-0"
WALL SECTION
1
1 1/2" = 1'-0"
EAVE DETAIL
2
CH401
WALL
SECTION &
DETAILS
© 2020 PEARCE SCOTT ARCHITECTS
PEARCE
SCOTT
ARCHITECTS
6 STATE OF MIND ST
SUITE 200
BLUFFTON, SC 29910
843.837.5700
RENOVATION FOR:
GERARD & BETH ROMSKI
LOT 20A, 5806 YAUPON ROAD
STOCK FARM
BLUFFTON, SC 29910
DESCRIPTION / REVISION LOGNO. INITIALDATE
PROJECT NO. 2075
DATE 10.20.20
DRAWN BY SDB
CHECKED BY AWB
SHEET NO.
DO NOT SCALE FROM DRAWINGSNOT FOR CONSTRUCTION
24X36 PAPER SIZE
CONCEPTUAL HPC SUBMITTAL AJD10.20.20
FINAL HPC SUBMITTAL - CH AJD11.03.20
ATTACHMENT 4
DUPLEX OUTLET
GROUND FAULT CIRCUIT INTERUPTER
WEATHER-PROOF OUTLET
SWITCHED OUTLET
220 V. OUTLET
FLOOR OUTLET
CABLE T.V. JACK
TELEPHONE JACK
SURFACE MOUNTED CEILING FIXTURE
CHANDELIER
WALL FIXTURE
EXHAUST FAN
SWITCH
THREE-WAY SWITCH
FOUR-WAY SWITCH
FAN SWITCH
CEILING FAN
RECESSED FIXTURE
GARBAGE DISPOSAL
PENDANT
DIMMER SWITCH
ELECTRICAL LEGEND
DATA
WALL WASHER
GENERAL ELECTRICAL PLAN NOTES:
1. COORDINATE W/ OWNER ELECTRICAL ROUGH-IN
LOCATIONS PRIOR TO START OF ELECTRICAL WORK.
2. INSTALL SMOKE DETECTORS IN ACCORDANCE WITH
SECTION R313 (SMOKE ALARMS) OF THE INTERNATIONAL
RESIDENTIAL CODE.
3. COORDINATE THERMOSTAT LOCATIONS W/ OWNER AND
PER FINAL HVAC RETURN GRILLE LOCATIONS.
4. COORDINATE LANDSCAPE LIGHTS AND GAS LAMP
POST LOCATIONS W/ LANDSCAPE ARCHITECT.
5. COORDINATE METER SIZE WITH CONTRACTOR
WATER PROOF RECESSED FIXTURE
SLOPED RECESSED FIXTURE
UNDER COUNTER LIGHT
GAS LIGHT
SMOKE DETECTOR
FLOURESCENT LIGHT
GARAGE DOOR OPENER
J JUNCTION BOX
METER - SIZE TBD BY CONTRACTOR
KING
TO LIGHT &
SWITCH BELOW
LIVING SPACE
002
CLOSET
004
BEDROOM
003
BATH
005
TIE INTO EXISTING
GARAGE ELECTRICAL
TO LIGHT &
SWITCH ABOVE
TIE INTO EXISTING
GARAGE ELECTRICAL
CART BAY
001
EXISTING GARAGE
ELECTRICAL TO REMAIN
ELECTRICAL
PLANS
1/4" = 1'-0"
FIRST FLOOR ELECTRICAL PLAN
1
CH-E101
© 2020 PEARCE SCOTT ARCHITECTS
PEARCE
SCOTT
ARCHITECTS
6 STATE OF MIND ST
SUITE 200
BLUFFTON, SC 29910
843.837.5700
RENOVATION FOR:
GERARD & BETH ROMSKI
LOT 20A, 5806 YAUPON ROAD
STOCK FARM
BLUFFTON, SC 29910
DESCRIPTION / REVISION LOGNO. INITIALDATE
PROJECT NO. 2075
DATE 10.20.20
DRAWN BY SDB
CHECKED BY AWB
SHEET NO.
DO NOT SCALE FROM DRAWINGSNOT FOR CONSTRUCTION
24X36 PAPER SIZE
CONCEPTUAL HPC SUBMITTAL AJD10.20.20
FINAL HPC SUBMITTAL - CH AJD11.03.20
1/4" = 1'-0"
SECOND FLOOR ELECTRICAL PLAN
2
ATTACHMENT 4
PLAN REVIEW COMMENTS FOR COFA-10-20-014698
Town of Bluffton
Department of Growth Management
20 Bridge Street P.O. Box 386 Bluffton, South Carolina 29910
Telephone 843-706-4522
OLD TOWN
Plan Type: Apply Date:
Plan Status: Plan Address: 5806 Yaupon Rd Road
BLUFFTON, SC 29910
Historic District
Active
10/22/2020
Plan PIN #:Case Manager: R610 039 000 1626 0000Katie Peterson
Plan Description: A request by Pearce Scott Architects, on behalf of owners, Gerard and Beth Romski, for review of a
Certificate of Appropriateness Application to allow for the addition of a golf cart bay and second floor of
approximately 599 SF to the existing Carriage House of approximately 514 SF located at 5806 Yaupon Road,
identified as Lot 20A in the Stock Farm Development, in the Old Town Bluffton Historic District and zoned
Neighborhood General – HD.
STATUS 10-27-2020: The application is currently being reviewed by Staff for conformance with the Unified
Development Ordinance (UDO), Traditional Construction Patterns, and any development plans associated
with the parcel and is scheduled for review by the HPRC at the November 16, 2020 meeting.
Staff Review (HD)
Submission #: 1 Recieved: 10/29/2020 Completed: 11/13/2020
Reviewing Dept. Complete Date StatusReviewer
Approved with Conditions11/13/2020Building Safety Review Richard Spruce
Comments:
1. Comments may be provided at Building Permit.
Approved with Conditions11/13/2020Growth Management Dept Review
(HD)
Katie Peterson
Comments:
1. For the Final submittal, a letter of approval from the Stock Farm HARC is required. (Applications Manual)
Approved with Conditions11/13/2020HPRC Review Katie Peterson
Comments:
1. For the final application provide architectural details of the railings and balusters, window detail, corner board trim, a typical wall
section, and a wall section through the eave depicting the material configuration and dimensions and photos of the primary structure
for context. (Applications Manual)
Approved11/10/2020Beaufort Jasper Water and Sewer
Review
James Clardy
Comments:
1. No Comment.
Approved11/10/2020Transportation Department Review
- HD
William Howard
Comments:
1. No Comment.
Approved11/12/2020Watershed Management Review William Baugher
Approved11/03/2020Addressing Review Nick Walton
11/13/2020 Page 1 of 2
ATTACHMENT 5
Plan Review Case Notes:
11/13/2020 Page 2 of 2
ATTACHMENT 5
STOCK FARM DEVELOPMENT
BOX 2570
BLUFFTON, SC 29910
15 December 2020
To: Katie Peterson, Town of Bluffton
Subject: HPC Review of Stock Farm Applications
Katie—It is understood that the HPC, in January, will review plans from two applicants and Stock Farm
property owners:
-----Romski-5806 Yaupon Road (Lot 20A)—Carriage House Additions
-----Eagen-5718 Guilford Place (Lot 45)—Personal Residence
Stock Farm has reviewed the plans and found these to meet the community requirements. It is
recommended that these plans be granted a Certificate of Appropriateness.
Emmett McCracken
Manager
ATTACHMENT 6
5718 Guilford Place, Lot 45 – Certificate of Appropriateness Historic Preservation Commission
HISTORIC PRESERVATION
COMMISSION
STAFF REPORT
Department of Growth Management
MEETING DATE: January 6, 2021
PROJECT: Lot 45, 5718 Guilford Place – New Construction:
Single-Family Residential
APPLICANT: Pearce Scott Architects
PROJECT MANAGER: Katie Peterson, AICP, Senior Planner
APPLICATION REQUEST: The Applicant, Pearce Scott Architects, on behalf of Kate
Eagen, requests that the Historic Preservation Commission approve the following
application:
1. COFA-10-20-014673. A Certificate of Appropriateness to allow the
construction of a 1.5-story single-family residential structure of
approximately 2,117 SF and a 2-story Carriage House of approximately
1,172 SF located at 5718 Guilford Place, Lot 45 in the Stock Farm
Development in the Old Town Bluffton Historic District, and zoned
Neighborhood General-HD.
INTRODUCTION: The Applicant is proposing the construction of a detached single-
family residence located in the Old Town Bluffton Historic District. The proposed
building, of approximately 2,117 SF, has similar attributes of the Village House, but
is not 2 stories in height, so it is reviewed as an Additional Building Type in
accordance with the allowable building types for the Neighborhood General-HD
zoning district. In addition to the primary structure, the Applicant is proposing a
Carriage House structure of approximately 1,172 SF, which meets the design
standards for a Carriage House Building Type. While this lot is located within the
Stock Farm Development, it was added to the development through a Development
Plan Amendment in 2018 (DPA-12-18-012661), which specified that the lot must
meet the setbacks found in the Unified Development Ordinance, which is different
than most lots within this development.
The main house structure is under a two-story forward-facing gable with a one-
story gabled projection to the rear. It features a front porch under a shed roof
which wraps around the left side and extends halfway back. The proposed
materials include combination of horizontal lap siding and vertical board and batten,
a 5V metal roof and the piers and chimneys are done in Tabby stucco.
The Carriage House, which features similar materials as the primary structure, is
connected by a breezeway to the primary structure. It is a two-story structure
under a gable roof with a second garage bay under a one-story shed roof.
January 6, 2021 Page 2
5718 Guilford Place, Lot 45 – Certificate of Appropriateness Historic Preservation Commission
This project was presented to the Historic Preservation Review Committee for
conceptual review at the November 2, 2020 meeting and comments were provided
to the Applicant (See attachment 6).
HISTORIC PRESERVATION COMMISSION ACTIONS: As granted by the powers and
duties set forth in Section 2.2.6.E.2, the Historic Preservation Commission has the
authority to take the following actions with respect to this application:
1. Approve the application as submitted by the Applicant;
2. Approve the application with conditions; or
3. Deny the application as submitted by the Applicant.
It is important to note that the intent of Section 5.15 Old Town Bluffton Historic
District of the Unified Development Ordinance (UDO) is that the Section be user
friendly and informative to the residents and the members of HPC and is not
intended to discourage creativity or force the replication of historic models. Rather,
it is to set forth a framework in which the diversity that has always characterized
Bluffton can continue to grow. The Section also defines guidelines for design and
materials similar to that used on structures within the Old Town, and it is the
charge of the HPC to assess the interpretation of these guidelines as they pertain to
applications using the established review criteria.
REVIEW CRITERIA & ANALYSIS: Town Staff and the Historic Preservation
Commission are required to consider the criteria set forth in Section 3.18.3 of the
UDO in assessing an application for a Certificate of Appropriateness – Historic
District (HD). The applicable criteria are provided below followed by a Staff
Finding(s) based upon review of the application submittals to date.
1. Section 3.18.3.B. Consistency with the principles set forth in the Old Town
Master Plan.
a. Finding. The application is consistent with the principles set forth in the
Old Town Master Plan. The Old Town Master Plan states that, “The built
environment, in particular the historic structures scattered throughout Old
Town, should be protected and enhanced. While it is of great importance
to save and restore historic structures, it is just as important to add to the
built environment in a way that makes Old Town more complete.”
The Applicant proposes to construct a new single-family residence and
Carriage House within the Old Town Bluffton Historic District, a locally and
nationally designated historic district. The buildings have been designed
to be sympathetic to the architectural character of the neighboring
historic structures, so their addition to the architectural diorama will both
protect the integrity of the existing historic structures and enhance the
neighborhood by adding architectural variety.
b. Finding. The Old Town Master Plan initiatives also include the adoption of
a form-based code that included architectural standards for structures
located within the Old Town Bluffton Historic District. These standards
are included in Article 5 of the UDO. The new construction proposed as
January 6, 2021 Page 3
5718 Guilford Place, Lot 45 – Certificate of Appropriateness Historic Preservation Commission
part of this request will be in conformance with those standards if the
conditions noted in item 2 of this Section are met.
c. Finding. The Old Town Master Plan initiatives also promote preservation
and protection of the legacy of the Old Town Bluffton Historic District
through additions to the built environment which make Old Town more
complete. The addition of the proposed residential structure and Carriage
House add to the district as well as help provide completeness to the
neighborhood and overall district.
2. Section 3.18.3.C. The application must be in conformance with applicable
provisions provided in Article 5, Design Standards.
a. Finding. Town Staff finds that the design of the primary structure falls
within the category of Additional Building Type as allowed in the
Neighborhood General Historic District per Section 5.15.5.C. Additional
Building Types are permissible. As has been past practice, the Town Staff
requests the Historic Preservation Commission review and make a final
recommendation regarding the appropriateness of the Additional Building
Type.
b. Finding. Town Staff finds that if the conditions noted below are met, the
proposed addition will be in conformance with applicable provisions
provided in Article 5:
1) Section 5.15.6.H. Columns, Arches, Piers, Railings, Balustrades.
The UDO states that columns and porch posts shall be spaced no
farther apart than they are tall. The proposed columns on the
front porch closest to the left side are spaced approximately 10’ 8”
apart on center and are 10’ 0” tall, and the furthest back bay on
the left elevation is proposed at 10’ 6” on center and are 10’ 0”
tall. The columns must be reconfigured to meet the dimensional
standards found in the UDO.
2) Section 5.15.6.I. Windows and Doors. Doors must be wood,
metal, or metal-clad. The door schedule notes fir- or similar,
however, Note 4 on the door schedule notes that door style shall
be specified by owner. Note 4 must be updated and exterior doors
selected by owner prior to approval.
3. Section 3.18.3.D. Consistency with the nature and character of the
surrounding area and consistency of the structure with the scale, form and
building proportions of the surrounding neighborhood.
Finding. Town Staff finds the nature and character of the new construction
to be consistent and harmonious with that of the surrounding neighborhood.
The mass and scale of the structure is appropriate for its location and the
architectural detailing is sensitive to the neighboring properties.
January 6, 2021 Page 4
5718 Guilford Place, Lot 45 – Certificate of Appropriateness Historic Preservation Commission
4. Section 3.18.3.F. The historic, architectural, and aesthetic features of the
structure including the extent to which its alteration or removal would be
detrimental to the public interest.
Finding. The Applicant seeks approval for the construction of new structures
in the Old Town Bluffton Historic District. The proposed plans are
sympathetic in design to the neighboring historic and non-historic resources;
therefore, the structure, as proposed, will have no adverse effect on the
public interest.
5. Section 3.18.3.H. The application must comply with applicable requirements
in the Applications Manual.
Finding. The application has been reviewed by Town Staff and has been
determined to be complete. However, it appears at there are a number of
trees over 14” in diameter that will require removal for the placement of the
structure. A Town of Bluffton tree removal permit must be submitted,
reviewed and approved prior to any site clearing. A 6” Magnolia has been
marked on the site plan to stay but is shown to be removed on the landscape
plan. Clarify if the magnolia should be removed or stay.
Additionally, a grading plan, showing all removal and fill for the site must be
provided prior to approval per Section 3.2.2.E. of the UDO, as not enough
information was provided at time of submittal. Please note that care shall be
given to root systems of trees to remain on the site.
STAFF RECOMMENDATION: It is the charge of the HPC to assess and interpret the
standards and guidelines set forth in the UDO as they pertain to applications using
the review criteria established in the UDO and to take appropriate action as granted
by the powers and duties set forth in Section 2.2.6.E.2. Town Staff finds that with
the conditions noted below, the requirements of Section 3.18.3 of the Unified
Development Ordinance have been met and recommends that the Historic
Preservation Commission approve the application with the following conditions:
1. Per Section 5.3.3.A.1. of the UDO, a Town of Bluffton tree removal permit
is required for the removal of any trees over 14” in DBH.
2. Provide clarification on the 6” magnolia shown to stay on the site plan but
removed on the landscape plan.
3. Per Section 5.15.6.H. of the UDO, columns must be reconfigured to be
spaced no farther apart than they are tall at the front left corner and the
left side in the last bay.
4. Per Section 5.15.6.I. of the UDO, the door style must be specified by
owner prior to approval and Note 4 on the door schedule updated.
5. Per Section 3.2.2.E. of the UDO, a Grading Plan for the site is required for
review as not enough information was provided at time of submittal.
ATTACHMENTS:
1. Location Map
2. Zoning Map
3. Application &Applicant Narrative
January 6, 2021 Page 5
5718 Guilford Place, Lot 45 – Certificate of Appropriateness Historic Preservation Commission
4. Site Plan & Elevations
5. Landscape Plan
6. HPRC Report
7. POA Approval Letter
5718 Guilford Place, Lot 45: Location Map
1 2 / 2 1 / 2 0 2 0
0 0 . 0 3 0 . 0 5 0 . 0 8 0 . 1 0 . 1 30 . 0 1
m i
F
ATTACHMENT 1
5718 Guilford Place, Lot 45: Zoning Map
1 2 / 2 1 / 2 0 2 0
0 0 . 0 3 0 . 0 5 0 . 0 8 0 . 1 0 . 1 30 . 0 1
m i
F
O v e r r id e 1
P a r c e l P r o p e r t y L in e s
ATTACHMENT 2
TOWN OF BLUFFTON
CERTIFICATE OF APPROPRIATENESS- OLD TOWN BLUFFTON
HISTORIC DISTRICT (HD) APPLICATION
Town of Bluffton Certificate of Appropriateness-Historic District Application Last Updated: 4/8/2014
Growth Management Customer Service Center
20 Bridge Street
Bluffton, SC 29910
(843)706-4522
www.townofbluffton.sc.gov
applicationfeedback@townofbluffton.com
Applicant Property Owner
Name: Name:
Phone: Phone:
Mailing Address: Mailing Address:
E-mail: E-mail:
Town Business License # (if applicable):
Project Information (tax map info available at http://www.townofbluffton.us/gis/)
Project Name: Conceptual: Final: Amendment:
Project Location: Application for:
New Construction
Renovation/Rehabilitation/Addition
Relocation or Demolition
Zoning District:
Acreage:
Tax Map Number(s):
Project Description:
Minimum Requirements for Submittal
1. Full sized copies and digital files of the Site Plan(s). One (1) set for Conceptual, two (2) sets for Final
2. Full sized copies and digital files of the Architectural Plan(s). One (1) set for Conceptual, two (2) sets for Final
3. Project Narrative describing reason for application and compliance with the criteri a in Article 3 of the UDO.
5. All information required on the attached Application Checklist.
6. An Application Review Fee as determined by the Town of Bluffton Master Fee Schedule. Checks made payable
to the Town of Bluffton.
Note: A Pre-Application Meeting is required prior to Application submittal.
Disclaimer: The Town of Bluffton assumes no legal or financial liability to the applicant or any
third party whatsoever by approving the plans associated with this permit.
I hereby acknowledge by my signature below that the foregoing application is complete and accurate and that I am
the owner of the subject property. As applicable, I authorize the subject property to be posted and inspected.
Property Owner Signature: Date:
Applicant Signature: Date:
For Office Use
Application Number: Date Received:
Received By: Date Approved:
ATTACHMENT 3
TOWN OF BLUFFTON
CERTIFICATE OF APPROPRIATENESS – HISTORIC DISTRICT
PROJECT ANALYSIS
Last Updated: 4/8/2014
In accordance with the Town of Bluffton Unified Development Ordinance (UDO), the following information shall
be included as part of a Certificate of Appropriateness application submitted for review by the Historic
Preservation Commission (HPC) and the Historic Preservation Review Committee . The use of this checklist by
Town Staff or the Applicant shall not constitute a waiver of any requirement contained in the UDO.
1. DESIGN REVIEW PHASE CONCEPTUAL REVIEW FINAL REVIEW
2. SITE DATA
Identification of Proposed Building Type (as defined in Article 5):
Building Setbacks Front: Rear: Rt. Side: Lt. Side:
3. BUILDING DATA
Building
Description
(Main House, Garage, Carriage
House, etc.)
Existing Square
Footage
Proposed Square
Footage
Main Structure
Ancillary
Ancillary
4. SITE COVERAGE
Impervious Coverage Coverage (SF)
Building Footprint(s)
Impervious Drive, Walks & Paths
Open/Covered Patios
A.TOTAL IMPERVIOUS COVERAGE
B.TOTAL SF OF LOT
% COVERAGE OF LOT (A/B= %)
5. BUILDING MATERIALS
Building Element Materials, Dimensions,
and Operation Building Element Materials, Dimensions,
and Operation
Foundation Columns
Walls Windows
Roof Doors
Chimney Shutters
Trim Skirting/Underpinning
Water table Cornice, Soffit, Frieze
Corner board Gutters
Railings Garage Doors
Balusters
Green/Recycled Materials
Handrails
ATTACHMENT 3
December 08, 2020
Lot 45 Stock Farm Narrative
On behalf of the owner, we would like to propose a Single Family Residence with a
Carriage House. The house will be located at the end of the Guilford Place Cul-de-sac.
The house is 2,117 heated square feet and the carriage house is 448 heated sf.
All details and materials will follow the UDO requirements.
The finished floor will be 36” above finished grade and the porches will be 30” above
finished grade. The landscape plan will show the grades.
We realize the column spacing on the wrapped corner is not in complete compliance
with the UDO, but we ask for a deviation as it is difficult to have the exact dimensions
when creating a corner element. The dimension from center of column to center of
column is 10’ 3” where as the height from top of porch to bottom of beam is 10’-0”.
The vertical member of the screening will give you the vertical proportion.
Please find attached pictures and drawings in this submittal.
Thank you for your consideration,
Amanda Jackson Denmark
Project Manager
ATTACHMENT 3
ATTACHMENT 3
ATTACHMENT 3
CVR
COVER SHEET
& DWG INDEX
DRAWING INDEX
EAGEN RESIDENCE at Stock Farm
Lot 45, Guilford Place
Final HPC Submittal - 12.08.20
CVR
S-A100
A001
A101
A102
A103
A104
A200
A201
A202
A203
A301
A401
A501
A502
A503
A504
A505
A601
E101
E102
COVER SHEET & DRAWING INDEX
SURVEY
ARCHITECTURAL FOUNDATION PLAN.
SITE PLAN
FIRST FLOOR PLAN
SECOND FLOOR PLAN
ROOF PLAN
C.H. FLOOR PLANS
OVERALL ELEVATIONS
EXTERIOR ELEVATIONS
EXTERIOR ELEVATIONS
CH EXTERIOR ELEVATIONS
BUILDING SECTIONS
WALL SECTIONS
DETAILS
DETAILS
DETAILS
DETAILS
WINDOW & DOOR DETAILS
WINDOW & DOOR SCHEDULES
FIRST FLOOR ELECTRICAL PLAN
SECOND FLOOR & C.H. ELECTRICAL PLANS
PROJECT TEAM
GENERAL NOTES:
1. The contractor is responsible for compliance, and
shall construct, to all applicable local, state, and
federal codes and regulations, in conformance to
all industry standards and methods of
construction, and per manufacturer's
recommended installations.
2. All materials will be new, unless otherwise
specified. All materials, finishes, and workmanship
will meet accepted industry standards, and will be
consistent with the plans regarding sizes. A
reasonable allowance on all dimensions is allowed
according to normal industry standards.
3. For dimensions not shown or in question, the
contractor will notify Architect of any discrepancies
or conflicts before proceeding.
4. For discrepancies or conflicts between the
architectural and engineering drawings, the
contractor shall request clarification from the
Architect before proceeding.
5. Contractor shall verify all existing field conditions.
Any discrepancies shall be brought to the attention
of the Architect.
6. Contractor to provide a sample board of exterior
materials, finishes and colors for final approval by
the Neighborhood/Development review board and
Owner.
7. Contractor to provide a job sign in accordance
with the neighborhood/development regulations.
8. The site is to be kept clean at all times for the
duration of the project.
9. The design documents are instruments of
professional service and shall remain the property
of Pearce Scott Architects. Such instruments shall
not be used by the client, or others, for any other
purposes without the prior written consent of the
Architect. The documents are a one-time only use.
10. The design documents are to be used for design
intent and in coordination with supplemental
engineering documents.
11. All walls are dimensioned to the face of stud or
masonry unless noted otherwise.
12. See structural engineering documents for
structural connection details and call-outs,
calculation and notes required by code, and
details for wall and roof connections including tie
down requirements.
13. The design documents do not indicate required
drainage and other site related work requirements.
See landscape, civil, or other supplemental
drawings.
14. When the Architect is contracted for construction
observation services by the owner, the Contractor
will coordinate with the Architect for progress visits
based on the schedule and availability of both
parties. Pay applications, if applicable, shall be
provided to the Architect prior to the meeting to
allow site review of work within the billing cycle.
PROJECT INFORMATION
AREA CALCULATIONS: (AJD - 12.04.20)
MAIN HOUSE:
FIRST FLOOR HEATED
SECOND FLOOR HEATED
MAIN HOUSE HEATED
ENTRY PORCH
SCREENED PORCH
SIDE PORCH
MAIN HOUSE UNHEATED
GROSS UNDER ROOF
CARRIAGE HOUSE:
SECOND FLOOR HEATED
GARAGE UNHEATED
GROSS UNDER ROOF
OVERALL PROJECT
TOTAL HEATED
GROSS UNDER ROOF
1,460
657
2,117
280
403
64
747
2,864
724
488
1,172
2,841
4,036
PROJECT ANALYSIS: (AJD - 10.14.20)
FRONT SETBACK:
REAR SETBACK:
RIGHT SETBACK:
LEFT SETBACK:
DRIVEWAY ACCESS:
MIN. FINISH FLR. ELEV.:
ACTUAL FINISH FLR. ELEV.:
BUILDING TYPE:
10'
25'
10'
10'
STREET
3'-0" A.F.G
3'-0" A.F.G
ADDITIONAL BUILDING TYPE
W/ VILLAGE HOUSE
CHARACTERISTICS
ARCHITECT:
Pearce Scott Architects
H. Pearce Scott, AIA
6 State of Mind, Suite 200
Bluffton, SC 29910
P: 843.837.5700
C: 843.816.6067
E: pearce@pscottarch.com
© 2020 PEARCE SCOTT ARCHITECTS
PEARCE
SCOTT
ARCHITECTS
6 STATE OF MIND ST
SUITE 200
BLUFFTON, SC 29910
843.837.5700
NEW RESIDENCE FOR:
KATE EAGEN
LOT 45 STOCK FARM
HISTORIC DISTRICT
BLUFFTON, SC 29910
DESCRIPTION / REVISION LOGNO. INITIALDATE
PROJECT NO. NO.
DATE 12.08.20
DRAWN BY AJD
CHECKED BY AWB
SHEET NO.
DO NOT SCALE FROM DRAWINGSNOT FOR CONSTRUCTION
24X36 PAPER SIZE
HPC CONCEPTUAL SUBMITTAL AJD10.14.20
HPC FINAL SUBMITTAL AJD12.08.20
LANDSCAPE ARCHITECT:
Witmer-Jones-Keefer
Dan Keefer
23 Promenade Street
Bluffton, SC 29910
P: 843.757.7411
C: 843.290.5437
E: dan@wjkltd.com
GENERAL CONTRACTOR:
DH Abney
David Abney
PO Box 452
Bluffton, SC 29910
C: 843.683.7873
E: david@dhabney.com
ATTACHMENT 4
ATTACHMENT 4
T.O. SLAB
6" A. FIN. GRADE
16'-0"12'-0"
23'-0"2'-6"
16'-0"12'-0"
28'-0"
28'-0"
2'-6"
28'-0"
SLOPE TO
DRAIN
SLOPE TO
DRAIN
POURED CONCRETE
LANDING FOR STAIRS
3'-0"
LINE OF
FOOTING
BELOW
4'-2"
9'-8" 9'-4" 9'-3" 11'-1"
2'-2"
2'-10"
10'-0" 6'-2" 5'-3" 6'-512" 7'-112" 6'-5" 8'-01 4" 12'-3"
35'-0" 26'-8"
61'-8"
39'-4"
2'-1112" 5'-7" 2'-612" 7'-7" 7'-8" 8'-0"
34'-4" 10'-6"
28'-6"
8'-8" 7'-8" 8'-2" 12'-6" 14'-8"
10'-4"
8'-10" 8'-4" 8'-10"
5'-6"4'-6"2'-0"
2'-0"
10'-0"
14'-8"
1'-0"
8" 8"
8" 8"
1'-0"
1'-0"
7'-10" 7'-4" 7'-10"
4'-10"11'-8"8'-6"
T.O. SLAB
4" A. FIN. GRADE
T.O. SLAB
4" A. FIN. GRADE
FOOTING BELOW
TOP FINISH FLOOR
3'-0" A. FIN. GRADE
TOP PORCH
2'-6" A. FIN. GRADE
TOP PORCH
2'-6" A. FIN. GRADE
16X16 PIER
12X12 PIER
8X16 PIER
LINE OF COLUMN ABOVE LINE OF COLUMN ABOVE
12X12 PIER
16X16 PIER
8X16 PIER
8X16 PIER
LINE OF COLUMN ABOVE
FOOTING BELOW
8" CMU WALL FOR
FIREPLACE, VERIFY
SIZE W/
MANUFACTURER,
SEE STRUCTURAL
8" CMU WALL FOR
FIREPLACE, VERIFY
SIZE W/
MANUFACTURER,
SEE STRUCTURAL
2'-8"
1.
2.
3.
NOTES:
ARCHITECTURAL FOUNDATION FOR
EXTERIOR DIMENSIONS & LEVEL CHANGES
ONLY. REFER TO STRUCTURAL FOR ALL
OTHER INFORMATION.
LEVEL CHANGES INDICATE TOP OF SLAB
STEP UPS ONLY--SEE SECTIONS &
DETAILS FOR INTENDED FINISHED FLOOR
TO FINISHED FLOOR LEVEL CHANGES.
CONTACT ARCHITECT IF MATERIALS
CHANGE, AS THIS WILL AFFECT FINISHED
FLOOR TO FINISHED FLOOR LEVEL
CHANGES.
REFER TO STRUCTURAL FOUNDATION
PLAN FOR CONTROL JOINT LOCATIONS
AND FOOTING SIZES AND DETAILS.
4.
CONTRACTOR TO COORDINATE ALL FIRST
FLOOR PLUMBING PRIOR TO SLAB POUR.
VERIFY FLOOR OUTLET LOCATIONS PRIOR
TO SLAB POUR.
5.
6.
7. ALL HARDSCAPE / PAVING, PADS, FILL &
GRADING TO BE COORD. BY CONTRACTOR
& LANDSCAPE ARCHITECT
1/4" = 1'-0"
ARCHITECTURAL FOUNDATION PLAN
1
S-A100
ARCH. FOUND.
PLAN
© 2020 PEARCE SCOTT ARCHITECTS
PEARCE
SCOTT
ARCHITECTS
6 STATE OF MIND ST
SUITE 200
BLUFFTON, SC 29910
843.837.5700
NEW RESIDENCE FOR:
KATE EAGEN
LOT 45 STOCK FARM
HISTORIC DISTRICT
BLUFFTON, SC 29910
DESCRIPTION / REVISION LOGNO. INITIALDATE
PROJECT NO. NO.
DATE 12.08.20
DRAWN BY AJD
CHECKED BY AWB
SHEET NO.
DO NOT SCALE FROM DRAWINGSNOT FOR CONSTRUCTION
24X36 PAPER SIZE
HPC CONCEPTUAL SUBMITTAL AJD10.14.20
HPC FINAL SUBMITTAL AJD12.08.20
N
ATTACHMENT 4
K-3429MEMOIRS TOILETS VITREOUS CHINA
K-3429 MEMOIRS TOILETS VITREOUS CHINA
K-710 IRON WORKS BATH KOHLER CAST IRON
10' BUILDING SETBACK
10' BUILDING SETBACK
10' BUILDING SETBACK
25' BUILDING SETBACK
26'-1 1
2"
8'-1 1
2"
5'-6"
31'-5
1 2"
49'-6"
35'-6"
5'-0"
PROPOSED
RESIDENCE
PROPOSED
CARRIAGE
HOUSE
DRIVE
MOTOR
COURT
WALK WAY
FINAL DRIVEWAY LAYOUT
SEE LANDSCAPE PLAN
1/8" = 1'-0"
SITE PLAN
1
A001
SITE PLAN
N
© 2020 PEARCE SCOTT ARCHITECTS
PEARCE
SCOTT
ARCHITECTS
6 STATE OF MIND ST
SUITE 200
BLUFFTON, SC 29910
843.837.5700
NEW RESIDENCE FOR:
KATE EAGEN
LOT 45 STOCK FARM
HISTORIC DISTRICT
BLUFFTON, SC 29910
DESCRIPTION / REVISION LOGNO. INITIALDATE
PROJECT NO. NO.
DATE 12.08.20
DRAWN BY AJD
CHECKED BY AWB
SHEET NO.
DO NOT SCALE FROM DRAWINGSNOT FOR CONSTRUCTION
24X36 PAPER SIZE
HPC CONCEPTUAL SUBMITTAL AJD10.14.20
HPC FINAL SUBMITTAL AJD12.08.20
ATTACHMENT 4
48" FIRE BOX
K-3429 MEMOIRS TOILETS VITREOUS CHINA
K-3429 MEMOIRS TOILETS VITREOUS CHINA
48" REF.
DW
DN
DN
ENTRY
PORCH
100
GREAT
ROOM
101
KITCHEN
102
MUDROOM /
LAUNDRY
103
POWDER
104
OWNER'S
BEDROOM
105
SIDE PORCH
108
SCREENED
PORCH
109
101B
101D
104A
107A 106A
107B
105A
103B
103A
A AA
B
UP
ISLAND
4'-0"X8'-0"
1 2
C.O.3'X8'
2X4
UP
2
36" RANGE
W
D
R&S
STORAGE
UNDER
LANDING
48" FIRE BOX
R&S
R&S
R&S
OWNER'S
WIC
106
H.B.
K-710 IRON WORKS BATH KOHLER CAST IRON
8'-6" VANITY
5'-6" TUB
6'-2" X 4'-0"
BENCH
101C
101A
B
103C
OWNER'S
BATH
107
A
4'-7"7'-8"4'-0"4'-0"
6'-5"
11'-2"2'-5"5'-3"2'-5"3'-9"
25'-0" 20'-3"10'-0"
61'-8"
3'-8"9'-8"12'-8"
2'-2" 26'-0"
6'-6" 5'-6"
40'-2"
2'-0"
2'-0"
5'-812" 9'-312" 9'-312" 5'-812"
2'-0"
7'-312"7'-312"5'-212" 5'-212" 6'-812" 12'-512" 7'-6"
16'-10"10'-6"
8'-0"7'-8"7'-7"2'-612"5'-7"2'-1112"
8"
34'-4"
30'-0"
10'-8"9'-8"9'-4"9'-8"8"
40'-0"
A
AAAA
B
2'-6"2'-6"
11'-6"11'-6"
H.B.
6'-0"
23'-0"
12'-0"
11'-8"
4'-10" 9'-0" 9'-0" 5'-8"
6'-0" 5'-8"
COVERED
CONNECTOR
004
6'-10"8'-1"
CL CL CL
CLCL CL
CLCL
CL
6'-5"
4
3
3
001C
109A
109B
2'-3" 6'-11" 3'-0"
2'-312"
9'-512" 4'-612" 12'-0"
5'-512" 12'-6" 9'-2"
4'-1"
3'-1112"
7'-112"
SERVICE
YARD
METER
HVAC
1112"
3'-0"
2'-2"
3'-1112"
AREA CALCULATIONS
MAIN HOUSE
CONDITIONED SPACE:
FIRST FLOOR
SECOND FLOOR
TOTAL COND.
UNCONDITIONED SPACE:
ENTRY PORCH
SCREENED PORCH
SIDE PORCH
TOTAL UNCOND.
MAIN HOUSE TOTAL
CH UNCONDITIONED:
GARAGE
CH CONDITIONED:
STUDIO
CH TOTAL
OVERALL TOTAL
1,460
657
2,117
280
403
64
747
2,864
724
448
1,172
4,036
1. 5 RISERS @ +/- 6", 4 TREADS @ 11" EA.
2. 10"X10" SQUARE COLUMN
3. 8"X8" SQUARE COLUMN
4. 2'-0" X 6'-8" SHOWER DOOR WITH CURB
NOTES
LEGEND
R&S: ROD AND SHELF
C.O.: CASED OPENING
H.B.: HOSE BIB
2X4: 2X4 STUD WALLS
1/4" = 1'-0"
FIRST FLOOR PLAN
1
A101
FIRST FLOOR
PLAN
© 2020 PEARCE SCOTT ARCHITECTS
PEARCE
SCOTT
ARCHITECTS
6 STATE OF MIND ST
SUITE 200
BLUFFTON, SC 29910
843.837.5700
NEW RESIDENCE FOR:
KATE EAGEN
LOT 45 STOCK FARM
HISTORIC DISTRICT
BLUFFTON, SC 29910
DESCRIPTION / REVISION LOGNO. INITIALDATE
PROJECT NO. NO.
DATE 12.08.20
DRAWN BY AJD
CHECKED BY AWB
SHEET NO.
DO NOT SCALE FROM DRAWINGSNOT FOR CONSTRUCTION
24X36 PAPER SIZE
HPC CONCEPTUAL SUBMITTAL AJD10.14.20
HPC FINAL SUBMITTAL AJD12.08.20
N SEE SHEET A104
ATTACHMENT 4
K-1123 ARCHER BATHING ACRYLIC
K-3429 MEMOIRS TOILETS VITREOUS CHINA
R&S
R&S
STORAGE
STAIR
HALL
200
BATH 2
201
BEDROOM 2
202
BEDROOM 3
203
203A
203B
202A
202B
200A 201A
201B
DN
SEE ELEVATIONS FOR
WINDOW HEAD HEIGHT
@ THIS LOCATION
2X4
2X4
2X4
2X4
9 RISERS @ +/- 7 11/16",
8 TREADS @ 11" EA.
9 RISERS @ +/- 7 11/16",
8 TREADS @ 11" EA.
DN
FLUEC
C D
D
3'-9"10'-1112"3'-612"3'-9" 3'-0"
25'-0"
5'-6" 5'-412" 9'-412" 4'-312" 5'-512"
30'-0"
4'-812"2'-012"4'-9"7'-6"6'-0"
5'-6"6'-4"6'-4"6'-4"5'-6"
30'-0"
25'-0"
C
C
C
C
D
15'-3" 14'-9"
4'-5"3'-1112"3'-112"13'-6"
7'-9" 3'-112" 4'-7" 5'-512"
AREA CALCULATIONS
MAIN HOUSE
CONDITIONED SPACE:
FIRST FLOOR
SECOND FLOOR
TOTAL COND.
UNCONDITIONED SPACE:
ENTRY PORCH
SCREENED PORCH
SIDE PORCH
TOTAL UNCOND.
MAIN HOUSE TOTAL
CH UNCONDITIONED:
GARAGE
CH CONDITIONED:
STUDIO
CH TOTAL
OVERALL TOTAL
1,460
657
2,117
280
403
64
747
2,864
724
448
1,172
4,036
1. 5 RISERS @ +/- 6", 4 TREADS @ 11" EA.
2. 10"X10" SQUARE COLUMN
3. 8"X8" SQUARE COLUMN
4. 2'-0" X 6'-8" SHOWER DOOR WITH CURB
NOTES
LEGEND
R&S: ROD AND SHELF
C.O.: CASED OPENING
H.B.: HOSE BIB
2X4: 2X4 STUD WALLS
1/4" = 1'-0"
SECOND FLOOR PLAN
1
A102
SECOND
FLOOR PLAN
© 2020 PEARCE SCOTT ARCHITECTS
PEARCE
SCOTT
ARCHITECTS
6 STATE OF MIND ST
SUITE 200
BLUFFTON, SC 29910
843.837.5700
NEW RESIDENCE FOR:
KATE EAGEN
LOT 45 STOCK FARM
HISTORIC DISTRICT
BLUFFTON, SC 29910
DESCRIPTION / REVISION LOGNO. INITIALDATE
PROJECT NO. NO.
DATE 12.08.20
DRAWN BY AJD
CHECKED BY AWB
SHEET NO.
DO NOT SCALE FROM DRAWINGSNOT FOR CONSTRUCTION
24X36 PAPER SIZE
HPC CONCEPTUAL SUBMITTAL AJD10.14.20
HPC FINAL SUBMITTAL AJD12.08.20
N
ATTACHMENT 4
RIDGERIDGE
PITCH BREAK
PITCH BREAK
HIP
8:12 SLOPE8:12 SLOPE
8:12 SLOPE8:12 SLOPE
4:12 SLOPE
4:12 SLOPE
4:12 SLOPE
4:12 SLOPE
8"
2'-0"
2'-0"
2'-0"
8"
2'-0"
2'-0"
8"
1'-0"
2'-0"
8"
2'-0"
1'-0"
2'-0"
LINE OF COLUMN BELOW
LINE OF FIRST FLOOR
WALL BELOW
LINE OF SECOND FLOOR
WALL BELOW
5-V CRIMP METAL ROOF
5-V CRIMP METAL ROOF
8:12
SLOPE
8:12 SLOPE8:12 SLOPE3:12 SLOPE
RIDGE
1'-0"
2'-0"
1'-0"
3'-0"2'-0"
8" 12'-6" 8" 1'-1"1'-1"
3:12 SLOPE
RIDGE
RIDGE
3:12 SLOPE3:12 SLOPE
LINE OF COLUMN BELOW
1'-0" VALLEY
VALLEY
1'-0"
1'-0"
2'-0"
CRICKET
CHIMNEY
CRICKET
CHIMNEY
8"
1/4" = 1'-0"
ROOF PLAN
1
A103
ROOF PLAN
© 2020 PEARCE SCOTT ARCHITECTS
PEARCE
SCOTT
ARCHITECTS
6 STATE OF MIND ST
SUITE 200
BLUFFTON, SC 29910
843.837.5700
NEW RESIDENCE FOR:
KATE EAGEN
LOT 45 STOCK FARM
HISTORIC DISTRICT
BLUFFTON, SC 29910
DESCRIPTION / REVISION LOGNO. INITIALDATE
PROJECT NO. NO.
DATE 12.08.20
DRAWN BY AJD
CHECKED BY AWB
SHEET NO.
DO NOT SCALE FROM DRAWINGSNOT FOR CONSTRUCTION
24X36 PAPER SIZE
HPC CONCEPTUAL SUBMITTAL AJD10.14.20
HPC FINAL SUBMITTAL AJD12.08.20
N
ATTACHMENT 4
K-3429 MEMOIRS TOILETS VITREOUS CHINA
R&S
DN
STUDIO
002
STUDIO BATH
003
16'-0" 4'-2"
8'-0"8'-0"
D
D
28'-0"
D
8'-0"8'-0"
16'-0"
28'-0"
002A
18 RISERS @ +/- 7 3/16",
17 TREADS @ 11" EA.
2X4
5'-0"
14'-0"
2X4
14'-0"
24" REF.
STACKED
W/D
BENCH
MICRO
2X4
2X42X4
2X4
R&S
4
002B
002C
003A 003B
AREA CALCULATIONS
MAIN HOUSE
CONDITIONED SPACE:
FIRST FLOOR
SECOND FLOOR
TOTAL COND.
UNCONDITIONED SPACE:
ENTRY PORCH
SCREENED PORCH
SIDE PORCH
TOTAL UNCOND.
MAIN HOUSE TOTAL
CH UNCONDITIONED:
GARAGE
CH CONDITIONED:
STUDIO
CH TOTAL
OVERALL TOTAL
1,460
657
2,117
280
403
64
747
2,864
724
448
1,172
4,036
1. 5 RISERS @ +/- 6", 4 TREADS @ 11" EA.
2. 10"X10" SQUARE COLUMN
3. 8"X8" SQUARE COLUMN
4. 2'-0" X 6'-8" SHOWER DOOR WITH CURB
NOTES
LEGEND
R&S: ROD AND SHELF
C.O.: CASED OPENING
H.B.: HOSE BIB
2X4: 2X4 STUD WALLS
R&S
A
3'-8"9'-8"12'-8"
26'-0"
40'-2"
A
GARAGE
001
28'-0"
UP
16'-0"12'-0"
2'-6"2'-6"
B
8'-0"8'-0"
001A
001B
11'-6"11'-6"
5'-0"5'-8"5'-8"11'-8"
CL
28'-0"
H.B.
6'-0" 6'-0"
23'-0"
12'-0" 16'-0"
B
12'-0"
9'-0" 5'-8"
6'-0" 5'-8"
6'-10"8'-1"
CL
6'-5"
3
3
001C
SERVICE
YARD
TRASH
HVAC
1/4" = 1'-0"
FIRST FLOOR PLAN
1
A104
C.H. FLOOR
PLANS
© 2020 PEARCE SCOTT ARCHITECTS
PEARCE
SCOTT
ARCHITECTS
6 STATE OF MIND ST
SUITE 200
BLUFFTON, SC 29910
843.837.5700
NEW RESIDENCE FOR:
KATE EAGEN
LOT 45 STOCK FARM
HISTORIC DISTRICT
BLUFFTON, SC 29910
DESCRIPTION / REVISION LOGNO. INITIALDATE
PROJECT NO. NO.
DATE 12.08.20
DRAWN BY AJD
CHECKED BY AWB
SHEET NO.
DO NOT SCALE FROM DRAWINGSNOT FOR CONSTRUCTION
24X36 PAPER SIZE
HPC CONCEPTUAL SUBMITTAL AJD10.14.20
HPC FINAL SUBMITTAL AJD12.08.20
N
1/4" = 1'-0"
SECOND FLOOR PLAN
2
SEE SHEET A101
ATTACHMENT 4
A200
OVERALL
ELEVATIONS
© 2020 PEARCE SCOTT ARCHITECTS
PEARCE
SCOTT
ARCHITECTS
6 STATE OF MIND ST
SUITE 200
BLUFFTON, SC 29910
843.837.5700
NEW RESIDENCE FOR:
KATE EAGEN
LOT 45 STOCK FARM
HISTORIC DISTRICT
BLUFFTON, SC 29910
DESCRIPTION / REVISION LOGNO. INITIALDATE
PROJECT NO. NO.
DATE 12.08.20
DRAWN BY AJD
CHECKED BY AWB
SHEET NO.
DO NOT SCALE FROM DRAWINGSNOT FOR CONSTRUCTION
24X36 PAPER SIZE
HPC CONCEPTUAL SUBMITTAL AJD10.14.20
HPC FINAL SUBMITTAL AJD12.08.20
1/8" = 1'-0"
LEFT ELEVATION W/ CONNECTOR
1
1/8" = 1'-0"
RIGHT ELEVATION W/ CONNECTOR
2
ATTACHMENT 4
HORIZONTAL LAP SIDING W/ 7"
EXPOSURE, TYP.
EXPOSED RAFTER TAILS, TYP.
2X6 TRIM BAND
2X6 TRIM BAND TO
ACT AS WINDOW SILL
5V CRIMP METAL ROOF
CRICKET
TABBY STUCCO CHIMNEY
2X WATER TABLE
& SKIRT BOARD
TABBY STUCCO
PIERS
5/4X6 WOOD
UNDERPINNING
WOOD HANDRAILS &
STEPS
WOOD DECKING
DECORATIVE GABLE
END BRACKET
10X10 WOOD
COLUMN
T.O. SUBFLOOR
+/- 2'-11 1/4" GRADE
T.O. PORCH
514" 8'-03 4"
10'-0"
11'-6"
T.O. DOOR
T.O. SUBFLOOR
9'-10"
B.O. BEAM
T.O. WINDOW
8'-03 4"
T.O. PLATE
9'-103 4"
8
12
4
12
2X6 CORNER
BOARD
VERTICAL BOARD AND
BATTEN 12" O.C.
4'-6"
4
A503
C C C C
T.O. SUBFLOOR
+/- 2'-11 1/4" GRADE
8'-03 4"
11'-6"
T.O. WINDOW
8'-03 4"
T.O. SUBFLOOR
T.O. WINDOW
T.O. PLATE
9'-53 4"
9'-103 4"
4'-6"
T.O. PLATE
10'-912"
4'-0"
10'-0"
B.O. BEAM
4
12
4
12
8
12
4
12
10X10 WOOD
COLUMN
TABBY STUCCO
CHIMNEY
2X6 TRIM BAND
2X6 TRIM BAND
2X WATER TABLE
& SKIRT BOARD
HORIZONTAL LAP
SIDING W/ 7"
EXPOSURE, TYP.
TABBY STUCCO
PIERS
2X6 CORNER
BOARD
VERTICAL BOARD AND
BATTEN 12" O.C.
CRICKET
2X6 TRIM BAND
VERTICAL BOARD AND
BATTEN 12" O.C.
5/4X6 WOOD
UNDERPINNING
WOOD HANDRAILS &
STEPS
CRICKET
DECORATIVE GABLE
END BRACKET
8
12
COVERED CONNECTOR
3
12
D
A A
1/4" = 1'-0"
FRONT ELEVATION
1
1/4" = 1'-0"
REAR ELEVATION
2
A201
EXTERIOR
ELEVATIONS
© 2020 PEARCE SCOTT ARCHITECTS
PEARCE
SCOTT
ARCHITECTS
6 STATE OF MIND ST
SUITE 200
BLUFFTON, SC 29910
843.837.5700
NEW RESIDENCE FOR:
KATE EAGEN
LOT 45 STOCK FARM
HISTORIC DISTRICT
BLUFFTON, SC 29910
DESCRIPTION / REVISION LOGNO. INITIALDATE
PROJECT NO. NO.
DATE 12.08.20
DRAWN BY AJD
CHECKED BY AWB
SHEET NO.
DO NOT SCALE FROM DRAWINGSNOT FOR CONSTRUCTION
24X36 PAPER SIZE
HPC CONCEPTUAL SUBMITTAL AJD10.14.20
HPC FINAL SUBMITTAL AJD12.08.20
ATTACHMENT 4
VERTICAL BOARD AND
BATTEN 12" O.C.
T.O. SUBFLOOR
+/- 2'-11 1/4" GRADE
T.O. PORCH
51 4" 8'-03 4"
11'-6"
T.O. WINDOW / DOOR
T.O. SUBFLOOR
T.O. WINDOW
8'-03 4"
10'-0"
B.O. BEAM
12'-6" +/- 13'-1012"
HORIZONTAL LAP
SIDING W/ 7"
EXPOSURE, TYP.
10X10 WOOD
COLUMN
EXPOSED
RAFTER TAILS,
TYP.
5V CRIMP
METAL ROOF
2X WATER TABLE
& SKIRT BOARD
TABBY STUCCO
PIERS
2X6 CORNER
BOARD
5/4X6 WOOD
UNDERPINNING
10X10 COLUMNWOOD HANDRAILS &
STEPS
WOOD DECKING SCREEN NOT SHOWN
2X6 TRIM BAND
TABBY STUCCO
CHIMNEY
5V CRIMP METAL ROOF
5
A503
COVERED CONNECTOR NOT SHOWN
4
12
D C
B BAAA
T.O. SUBFLOOR
+/- 2'-11 1/4" GRADE
T.O. PORCH
514" 8'-03 4"
11'-6"
T.O. WINDOW
T.O. SUBFLOOR
T.O. WINDOW
8'-03 4"
13'-6" +/- 22'-112"
HORIZONTAL LAP SIDING W/ 7"
EXPOSURE, TYP.
EXPOSED RAFTER TAILS, TYP.
5 V CRIMP METAL ROOF
TABBY STUCCO CHIMNEY
2X WATER TABLE
& SKIRT BOARD
TABBY STUCCO
PIERS
2X6 CORNER
BOARD
VERTICAL BOARD AND
BATTEN 12" O.C.
2X6 TRIM BAND TO
ACT AS WINDOW SILL
WOOD DECKING SCREEN NOT SHOWNWOOD HANDRAILS &
STEPS
5/4X6 WOOD
UNDERPINNING
VERTICAL BOARD AND
BATTEN 12" O.C.
10X10 COLUMN
10'-0"
B.O. BEAM
4
12
C D
BA AAA
2
A503
5'-6"
1/4" = 1'-0"
LEFT ELEVATION
1
1/4" = 1'-0"
RIGHT ELEVATION
2
A202
EXTERIOR
ELEVATIONS
© 2020 PEARCE SCOTT ARCHITECTS
PEARCE
SCOTT
ARCHITECTS
6 STATE OF MIND ST
SUITE 200
BLUFFTON, SC 29910
843.837.5700
NEW RESIDENCE FOR:
KATE EAGEN
LOT 45 STOCK FARM
HISTORIC DISTRICT
BLUFFTON, SC 29910
DESCRIPTION / REVISION LOGNO. INITIALDATE
PROJECT NO. NO.
DATE 12.08.20
DRAWN BY AJD
CHECKED BY AWB
SHEET NO.
DO NOT SCALE FROM DRAWINGSNOT FOR CONSTRUCTION
24X36 PAPER SIZE
HPC CONCEPTUAL SUBMITTAL AJD10.14.20
HPC FINAL SUBMITTAL AJD12.08.20
ATTACHMENT 4
+/- 6" GRADE
8'-0"
10'-111 4"
T.O. SLAB
T.O. SUBFLOOR
T.O. WINDOW
7'-03 4"
T.O. DOOR
HORIZONTAL LAP
SIDING W/ 7"
EXPOSURE, TYP.
VERTICAL BOARD AND
BATTEN 12" O.C.
2X6 TRIM BAND TO
ACT AS WINDOW SILL
EXPOSED
RAFTER TAILS,
TYP.
METAL ROOF
8
12
2
A502
COVERED CONNECTOR
3
12
8X8 COLUMN
GRADE
T.O. WALK
B.O. BEAM
9'-0"4"
D
+/- 6" GRADE
9'-6"
10'-1114"
T.O. SLAB
T.O. SUBFLOOR
T.O. DOOR
B.O. BEAM
7'-03 4"
3'-03 4"
EXPOSED
RAFTER TAILS,
TYP.
5V CRIMP METAL ROOF
8
12
8X8 COLUMNWOOD HANDRAILS & STEPS
HORIZONTAL LAP
SIDING W/ 7"
EXPOSURE, TYP.
VERTICAL BOARD AND
BATTEN 12" O.C.
2X6 TRIM BAND
2X6 CORNER BOARD
5
A503
5'-0"
3
12
+/- 6" GRADE
9'-612"
T.O. SLAB
T.O. PLATE
T.O. DOOR
8'-0"
VERTICAL BOARD AND
BATTEN 12" O.C.
2X6 TRIM BAND TO
ACT AS WINDOW SILL
DECORATIVE GABLE
END BRACKET
8
12
4'-6"
METAL ROOF
2X6 CORNER BOARD
D
3
12
+/- 6" GRADE
314"
10'-1114"
T.O. SLAB
T.O. WINDOW
7'-03 4"
T.O. WINDOW
T.O. PLATE
8'-0"
T.O. SUBFLOOR
T.O. PORCH
9'-012" HORIZONTAL LAP
SIDING W/ 7"
EXPOSURE, TYP.
2X6 CORNER
BOARD
VERTICAL BOARD AND
BATTEN 12" O.C.
DECORATIVE GABLE
END BRACKET
8
12
4'-6"
WOOD HANDRAIL
8X8 COLUMN
2X6 TRIM BAND TO
ACT AS WINDOW SILL
D
B B
1/4" = 1'-0"
FRONT ELEVATION
1
1/4" = 1'-0"
REAR ELEVATION
2
A203
CH EXTERIOR
ELEVATIONS
© 2020 PEARCE SCOTT ARCHITECTS
PEARCE
SCOTT
ARCHITECTS
6 STATE OF MIND ST
SUITE 200
BLUFFTON, SC 29910
843.837.5700
NEW RESIDENCE FOR:
KATE EAGEN
LOT 45 STOCK FARM
HISTORIC DISTRICT
BLUFFTON, SC 29910
DESCRIPTION / REVISION LOGNO. INITIALDATE
PROJECT NO. NO.
DATE 12.08.20
DRAWN BY AJD
CHECKED BY AWB
SHEET NO.
DO NOT SCALE FROM DRAWINGSNOT FOR CONSTRUCTION
24X36 PAPER SIZE
HPC CONCEPTUAL SUBMITTAL AJD10.14.20
HPC FINAL SUBMITTAL AJD12.08.20
1/4" = 1'-0"
RIGHT ELEVATION
4
1/4" = 1'-0"
LEFT ELEVATION
3
ATTACHMENT 4
T.O. FIN. FLOOR
+/- 3'-0"
GRADE
T.O. PORCH
6" 8'-0"
11'-514"
T.O. WINDOW / DOOR
T.O. SUBFLOOR
T.O. WINDOW / DOOR
8'-03 4"
T.O. PLATE
9'-103 4"
10X10 COLUMN
8
12
4
12
TO
LAUNDRY KITCHEN
ISLAND
KITCHEN
102
TO HALL
BEDROOM 2
202
BEDROOM 3
203
TO
STAIR
HALL
TO
STAIR
HALL
TO
CLOSET
TO
CLOSET
STORAGE UNDER
STAIR, FIELD
ADJUST
HANDRAIL TBD
BY OWNER
16" FLOOR SYSTEM
2X COLLAR TIE,
SEE STRUCTURAL
INTERIOR
SUPPORT AS
REQUIRED BY
STRUCTURAL
2X8 CEILING FRAMING
2X8 ROOF FRAMING
2X8 ROOF FRAMING
ATTIC
2X8 ROOF FRAMING
2X8 CEILING FRAMING
SCREENED
PORCH
109
10'-0"
9'-0"
TO
STUDIO
BATH
CLOSET
STUDIO
002
GARAGE
001
T.O. SLAB
+/- 6"
GRADE
10'-111 4"
T.O. SUBFLOOR
T.O. PORCH
31 4"
T.O. PLATE
9'-11 4"
7'-03 4"8'-0"
T.O. SLAB
GRADE
T.O. PLATE
+/- 6" 9'-612"
8
12
2X8 ROOF FRAMING
2X8 CEILING FRAMING
2X8 ROOF FRAMING
2X8 ROOF FRAMING
2X8 CEILING FRAMING16" FLOOR SYSTEM
5/8 TYPE "X"
GYP.
3
12
9'-6"
9'-0"
3
A501
A301
BUILDING
SECTIONS
© 2020 PEARCE SCOTT ARCHITECTS
PEARCE
SCOTT
ARCHITECTS
6 STATE OF MIND ST
SUITE 200
BLUFFTON, SC 29910
843.837.5700
NEW RESIDENCE FOR:
KATE EAGEN
LOT 45 STOCK FARM
HISTORIC DISTRICT
BLUFFTON, SC 29910
DESCRIPTION / REVISION LOGNO. INITIALDATE
PROJECT NO. NO.
DATE 12.08.20
DRAWN BY AJD
CHECKED BY AWB
SHEET NO.
DO NOT SCALE FROM DRAWINGSNOT FOR CONSTRUCTION
24X36 PAPER SIZE
HPC CONCEPTUAL SUBMITTAL AJD10.14.20
HPC FINAL SUBMITTAL AJD12.08.20
1/4" = 1'-0"
C.H.BUILDING SECTION
2
1/4" = 1'-0"
BUILDING SECTION
1
ATTACHMENT 4
T.O. SUBFLOOR
GRADE
+/- 2'-11 1/4"
SET T.O. FIN. FLOOR
3'-0" ABOVE FIN. GRADE
6
A501
T.O. PLATE
8
12
9'-10 3/4"
2'-0"
1
A501
2X6 STUD WALL @ 16" O.C.
W/ BATT INSULATION
16" FLOOR SYSTEM
2X BLOCKING AS
NEEDED FOR TRIM
11'-6"
10'-0"
1/2" GYPSUM BOARD
1/2" GYPSUM BOARD
3/4" PLYWOOD SUBFLOOR
T.O. SUBFLOOR
3'-0 3/4"
HORIZONTAL LAP SIDING W/ 7"
EXPOSURE, TYP.
VERTICAL BOARD AND
BATTEN 12" O.C.
FLASHING
2X6 W/ CHAMFER,
OVER BLOCKING
2X6 BASE PLATE
FINISHED FLOOR
+/- 6" GRADE
T.O. SUBFLOOR
5
A501
10'-11 1/4"
9'-6"
T.O. SUBFLOOR
T.O. PLATE
8
12
2'-0"
9'-1 1/4"
9'-0"
2X6 STUD WALL @ 16" O.C.
W/ BATT INSULATION
16" FLOOR SYSTEM
2X BLOCKING AS
NEEDED FOR TRIM
1/2" GYPSUM BOARD
1/2" GYPSUM BOARD
3/4" PLYWOOD SUBFLOOR
3'-0 3/4"
HORIZONTAL LAP SIDING W/ 7"
EXPOSURE, TYP.
VERTICAL BOARD AND
BATTEN 12" O.C.
FLASHING
2X6 W/ CHAMFER,
OVER BLOCKING
2X6 BASE PLATE
FINISHED FLOOR
4
A501
T.O. SUBFLOOR
GRADE
+/- 2'-11 1/4"
10'-10"
T.O. PLATE
SET T.O. FIN. FLOOR
3'-0" ABOVE FIN. GRADE
8
12
2'-0"
2
A501
6
A501
A401
WALL
SECTIONS
© 2020 PEARCE SCOTT ARCHITECTS
PEARCE
SCOTT
ARCHITECTS
6 STATE OF MIND ST
SUITE 200
BLUFFTON, SC 29910
843.837.5700
NEW RESIDENCE FOR:
KATE EAGEN
LOT 45 STOCK FARM
HISTORIC DISTRICT
BLUFFTON, SC 29910
DESCRIPTION / REVISION LOGNO. INITIALDATE
PROJECT NO. NO.
DATE 12.08.20
DRAWN BY AJD
CHECKED BY AWB
SHEET NO.
DO NOT SCALE FROM DRAWINGSNOT FOR CONSTRUCTION
24X36 PAPER SIZE
HPC CONCEPTUAL SUBMITTAL AJD10.14.20
HPC FINAL SUBMITTAL AJD12.08.20
1" = 1'-0"
C.H. 2 STORY WALL SECTION
3 1" = 1'-0"
2 STORY WALL SECTION
11" = 1'-0"
1 STORY WALL SECTION
2
ATTACHMENT 4
HURRICANE CLIP @
EA. RAFTER
2X8 RAFTERS @ 16" O.C.,
SEE STRUCTURAL
SPRAY FOAM INSULATION
AT ALL ROOFS, TYP.
METAL DRIP EDGE
5-V CRIMP METAL ROOF
OVER ICE AND WATER SHIELD
EXTERIOR ROOF SHEATHING
1X4 TRIM
2'-0", TYP.
1X4 HARDIE SOFFIT
5/4X TRIM OVER BLOCKING
(2) 2X6 TOP PLATE
2X8 CEILING FRAMING
8
12NOTE: PER CODE, RAFTER
NOTCH CANNOT EXCEED
25% DEPTH OF RAFTER
1/3
2/3
P.T. 2X6
SISTERED ON
EXPOSED RAFTER
W/ 13 EXPOSURE
1/2" GYPSUM BOARD
2X6 TOP PLATE
HURRICANE CLIP @
EA. RAFTER
2X8 RAFTERS @ 16" O.C.,
SEE STRUCTURAL
SPRAY FOAM INSULATION
AT ALL ROOFS, TYP.
METAL DRIP EDGE
5-V CRIMP METAL ROOF
OVER ICE AND WATER SHIELD
EXTERIOR ROOF SHEATHING
1X4 TRIM
2'-0", TYP.
1X4 HARDIE SOFFIT
5/4X TRIM OVER BLOCKING
(2) 2X6 TOP PLATE
2X8 CEILING FRAMING
2X6 TOP PLATE
8
12NOTE: PER CODE, RAFTER
NOTCH CANNOT EXCEED
25% DEPTH OF RAFTER
1/3
2/3
P.T. 2X6
SISTERED ON
EXPOSED RAFTER
W/ 13 EXPOSURE
3/4" PLYWOOD SUBFLOOR
1/2" GYPSUM BOARD
HURRICANE CLIP @
EA. RAFTER
2X8 RAFTERS @ 16" O.C.,
SEE STRUCTURAL
SPRAY FOAM INSULATION
AT ALL ROOFS, TYP.
METAL DRIP EDGE
5-V CRIMP METAL ROOF
OVER ICE AND WATER SHIELD
EXTERIOR ROOF SHEATHING
1X4 TRIM
2'-0", TYP.
1X4 HARDIE SOFFIT
5/4X TRIM OVER BLOCKING
(2) 2X6 TOP PLATE
2X8 CEILING FRAMING
8
12NOTE: PER CODE, RAFTER
NOTCH CANNOT EXCEED
25% DEPTH OF RAFTER
1/3
2/3
P.T. 2X6
SISTERED ON
EXPOSED RAFTER
W/ 13 EXPOSURE
1/2" GYPSUM BOARD
2X6 BASE PLATE
2X BLOCKING AS
NEEDED FOR TRIM
2X6 STUD WALL @ 16" O.C.
W/ BATT INSULATION
SIDING -SEE ELEVATIONS
MOISTURE BARRIER
OVER 1/2" EXTERIOR SHEATHING
3/4" PLYWOOD SUBFLOOR
FINISHED FLOOR
2X FLOOR JOISTS,
SEE STRUCTURAL
CONTINUOUS METAL FLASHING -
LAP MOISTURE BARRIER
OVER FLASHING
SEALANT - UNDER FLASHING
2"
FOUNDATION,
SEE STRUCTURAL
TABBY STUCCO FINISH
CONT. METAL
WEEP SCREED
CASING BEAD, TYP.
HARDIE 2X6 RIPPED IN
HALF, CHAMFERED
2X12 SKIRT BOARD
30°
P.T. 2X STARTER STRIP W/
METAL FLASHING
MOISTURE BARRIER
OVER 1/2" EXTERIOR SHEATHING
ANCHOR BOLT PER
STRUCTURAL
BLOCKING AS REQ'D FOR TRIM
INTERIOR WALL FINISH
P.T. STARTER STRIP
FOUNDATION,
SEE STRUCTURAL
GRADE - SLOPE TO DRAIN
P.T. 2X6 BASE PLATE
+/- 6"
CONTINUOUS METAL FLASHING, LAP
MOISTURE BARRIER OVER FLASHING
EXTEND UP WALL MIN. 16"
SIDING, SEE ELEVATION
2X6 STUD WALL @ 16" O.C.
HURRICANE CLIP @
EA. RAFTER
2X8 RAFTERS @ 16" O.C.,
SEE STRUCTURAL
SPRAY FOAM INSULATION
AT ALL ROOFS, TYP.
METAL DRIP EDGE
5-V CRIMP METAL ROOF
OVER ICE AND WATER SHIELD
EXTERIOR ROOF SHEATHING
1X4 TRIM
1'-0", TYP.
1X4 HARDIE SOFFIT
5/4X TRIM OVER BLOCKING
(2) 2X6 TOP PLATE
2X8 CEILING FRAMING
3
12 NOTE: PER CODE, RAFTER
NOTCH CANNOT EXCEED
25% DEPTH OF RAFTER
P.T. 2X6
SISTERED ON
EXPOSED RAFTER
W/ 13 EXPOSURE
1/2" GYPSUM BOARD
1/3
2/3
A501
DETAILS
© 2020 PEARCE SCOTT ARCHITECTS
PEARCE
SCOTT
ARCHITECTS
6 STATE OF MIND ST
SUITE 200
BLUFFTON, SC 29910
843.837.5700
NEW RESIDENCE FOR:
KATE EAGEN
LOT 45 STOCK FARM
HISTORIC DISTRICT
BLUFFTON, SC 29910
DESCRIPTION / REVISION LOGNO. INITIALDATE
PROJECT NO. NO.
DATE 12.08.20
DRAWN BY AJD
CHECKED BY AWB
SHEET NO.
DO NOT SCALE FROM DRAWINGSNOT FOR CONSTRUCTION
24X36 PAPER SIZE
HPC CONCEPTUAL SUBMITTAL AJD10.14.20
HPC FINAL SUBMITTAL AJD12.08.20
8:12 EAVE DETAIL @ 2 STORY
1 1 1/2" = 1'-0"
8:12 EAVE DETAIL @ 1 STORY
2 1 1/2" = 1'-0"
8:12 EAVE DETAIL @ C.H.
4 1 1/2" = 1'-0"
TYP. FOUNDATION DETAIL
6 1 1/2" = 1'-0"
3:12 EAVE DETAIL @ C.H.
3 1 1/2" = 1'-0"
FOUNDATION DETAIL @ C.H.
5 1 1/2" = 1'-0"
ATTACHMENT 4
P.T. 2X4 NAILED
TO SILL PLATE
VERTICAL P.T. 1X6 W/ EQ.
1" GAP SPACING,
INSTALL AFTER STUCCO
TABBY STUCCO
TO WRAP CMU BLOCK
GAP @ FINISH GRADE
FOR DRAINAGE
COLUMN BEYOND
GALV. RODENT SCREENING,
MIN. 6" UNDER GROUND
2"
5/4X DECKING
5/4 X TRIM OVER
P.T. BLOCKING
3"
FOUNDATION,
SEE STRUCTURAL
3
12
10"
2X RAFTERS @ 16" O.C.,
SEE STRUCTURAL
ROOF MATERIAL OVER
ICE & WATER SHIELD,
SEE ELEVATIONS
EXTERIOR
ROOF SHEATHING
BEAM , SEE STRUCTURAL
5/4X TRIM OVER BLOCKING
2'-0"
10"
1X4 HARDIE SOFFIT
5/4X TRIM
2X TRIM
FLASHING
HURRICANE CLIP @
EA. RAFTER
2X FLOOR JOIST @ 16" O.C.,
SEE STRUCTURAL
5/4X T&G DECKING
SLOPE TO DRAIN
COUPLER
MITRED CORNERS
2X COLUMN
1"
2X4 SEAT
TIE-DOWN SYSTEM,
SEE STRUCTURAL
P.T. 2X4 COLUMN BASE
TERMITE SHIELD
P.T. 2X PLATETABBY STUCCO
5/4 X TRIM OVER
P.T. BLOCKING
PORCH BEAM,
SEE STRUCTURAL
TIE-DOWN SYSTEM,
SEE STRUCTURAL
5/4X10 BASE TRIM
P.T. 2X4 FRAME
METAL DRIP EDGE
1X4 HARDIE TRIM
SISTERED ON EXPOSED
RAFTER TAILS
ALIGN
"SCREENTIGHT" CHANNEL
SCREEN FRAME BEYOND
PT 2X4
FRAME
COLUMN BEYOND,
AS PER ELEVATION SCREEN
10"
"SCREENTIGHT" CHANNEL
8" X 8" COLUMN, TYP.
P.T. 2X4
FRAME
CONT. P.T. 2X4
"SCREENTIGHT"
CHANNEL
PROVIDE 1/2" X 3"
OPENINGS CENTERED ON
EA. PANEL & 2'-0" O.C. TO
ALLOW WATER TO DRAIN
21
2" T.O. DECK
SCREEN
INTERIOR EXTERIOR
P.T. 2X6
DRINK RAIL
"SCREENTIGHT" CHANNEL
2'-6"
SCREEN
SCREEN FRAMING
BEYOND
PLAN VIEW
VERTICAL
"SCREENTIGHT"
CHANNEL BEYOND
3"21
2"
2"
51
2"
(2) 3
4" DIA. LAG SCREWS (MIN. 4" PEN. IN TO
BLOCKING), PLUG WITH LIKE WOOD
P.T. 6X6 BRACKET
P.T. 2X6 VERTICAL WALL SUPPORT @ EA. BRACKET
(2) 2X P.T. BLOCKING
@ EA. BRACKET
P.T. 6X6 BRACKET,
CUT TO SHAPE
12
P.T. 8X8 BEAM
2X8 RAFTER
51
2"
3'-2"
5/4X 10 TRIM OVER
P.T. 2X CONT. LEDGER
HANGER
1
2" DIA. LAG SCREW
(MIN. 2.5" PEN. INTO 6X6),
PLUG WITH LIKE WOOD
5
8" DIA. GALV. THRU BOLT
(COUNTERSINK)
1
2" DIA. LAG SCREW
(MIN. 2.5" PEN.)
2'-0"
(2) 2X P.T. BLOCKING
@ EA. BRACKET
1X4 HARDIE SOFFIT
P.T. 2X6
METAL DRIP EDGE
3'-0"
3"
45°
EXPOSED RAFTER TAIL
8
HURRICANE CLIP @
EA. RAFTER
1X4 HARDIE
TRIM
3" 3"21
2"
A502
DETAILS
© 2020 PEARCE SCOTT ARCHITECTS
PEARCE
SCOTT
ARCHITECTS
6 STATE OF MIND ST
SUITE 200
BLUFFTON, SC 29910
843.837.5700
NEW RESIDENCE FOR:
KATE EAGEN
LOT 45 STOCK FARM
HISTORIC DISTRICT
BLUFFTON, SC 29910
DESCRIPTION / REVISION LOGNO. INITIALDATE
PROJECT NO. NO.
DATE 12.08.20
DRAWN BY AJD
CHECKED BY AWB
SHEET NO.
DO NOT SCALE FROM DRAWINGSNOT FOR CONSTRUCTION
24X36 PAPER SIZE
HPC CONCEPTUAL SUBMITTAL AJD10.14.20
HPC FINAL SUBMITTAL AJD12.08.20
COLUMN DETAIL
1 1 1/2" = 1'-0"
SCREEN DETAIL
3 1 1/2" = 1'-0"
BRACKET DETAIL
2 1 1/2" = 1'-0"
ATTACHMENT 4
1'-0"
METAL DRIP EDGE
P.T. 2X FLY
RAFTERS
1X4 HARDIE SOFFIT
SIDING,
SEE ELEVATIONS
P.T. 2X OUTLOOKERS
@ 24" O.C.
TRIM/RAFTER TO CREATE
FRIEZE TO EXTEND DOWN
FACE OF GABLE END
31
2"
1X4 HARDIE TRIM
METAL ROOF
OVER ICE & WATER SHIELD
EXTERIOR
ROOF SHEATHING
4"SEE ELEVATIONS3"
4" CONC. SLAB WITH W.W.M.
REINFORCING. TURN DOWN
SLAB AT EDGES
HORIZONTAL
P.T. 1X6,
BOTH SIDES
VERTICAL P.T. 1X6,
ALTERNATE SIDES FOR
VENTILATION
3X6 P.T. TOP RAIL,
DOUBLE SLOPED TOP
3X8 P.T. NEWEL
CAP ON 6X6 POST
(SLOPED ON ALL
4 SIDES) 51
2" 1"1"
3
4"13
4"
FRONT SIDE
SIMPSON CONCEALED POST TIE
HORIZONTAL
P.T. 1X6,
BOTH SIDES
1"11
2"
P.T. 2X4
FRAME HORIZONTAL P.T. 2X4 AS
NEEDED FOR STABILITY
SIDING REF ELEVATAIONS
1/2" SHEATHING
2X TRIM
FULL MEMBER TO FACE
BITUMEN SPLINE ON SHEATHING -
MOISTURE BARRIER
EXTEND 12" EACH DIRECTION
51
2"
THERMAL INSULATION
51
2"
INTERIOR
SPARK ARRESTOR
PER MANUFACTURER
RECOMMENDATION
FOR METAL FLUE
STUCCO VENEER
+/- 2'-6"
1" 1"
4" 73
4" +/- 1'-7 1
4"
7 1
4"
51
2"
3"
STUCCO VENEER
R1'-7
34"
4X4 P.T. NEWEL
POST W/ CAP
5/4 X TREADS
& RISERS
P.T. 2X4 TOP RAIL,
DOUBLE SLOPED TOP
3'-0"
+/- 6"
1"
11"
6"
1"3'-0"
NUMBER OF STEPS
DETERMINED BY FINAL
GRADING
P.T. 2X4 TOP RAIL,
DOUBLE SLOPED TOP
P.T.
HORIZONTAL
1X4 BOARDS
P.T. 1X4
1" 2 1
4"
3'-0"
4X4 P.T. NEWEL
POST W/ CAP
5/4 X TREADS
& RISERS
3'-0"+/- 6"
1"
11"
6"
P.T. 2X4 TOP RAIL,
DOUBLE SLOPED TOP
2" TYP.
NUMBER OF STEPS
DETERMINED BY FINAL
GRADING
LOCATION: CARRIAGE HOUSELOCATION: MAIN HOUSE
+/- 2"
2"
P.T. 5/4X6 W/ EQ.
1" GAP SPACING,
INSTALL AFTER STUCCO
GALV. RODENT SCREENING,
MIN. 18" UNDER GROUND
GAP @ FINISH GRADE
FOR DRAINAGE
1"
11
2"
TABBY STUCCO
P.T. 2X4 NAILED
TO SILL PLATE
P.T. 2X4 FRAME SCREWED TO
CMU BLOCK @ PIERS
FOUNDATION,
SEE STRUCTURAL
A503
DETAILS
© 2020 PEARCE SCOTT ARCHITECTS
PEARCE
SCOTT
ARCHITECTS
6 STATE OF MIND ST
SUITE 200
BLUFFTON, SC 29910
843.837.5700
NEW RESIDENCE FOR:
KATE EAGEN
LOT 45 STOCK FARM
HISTORIC DISTRICT
BLUFFTON, SC 29910
DESCRIPTION / REVISION LOGNO. INITIALDATE
PROJECT NO. NO.
DATE 12.08.20
DRAWN BY AJD
CHECKED BY AWB
SHEET NO.
DO NOT SCALE FROM DRAWINGSNOT FOR CONSTRUCTION
24X36 PAPER SIZE
HPC CONCEPTUAL SUBMITTAL AJD10.14.20
HPC FINAL SUBMITTAL AJD12.08.20
RAKE DETAIL
1 1 1/2" = 1'-0"
SERVICE YARD
2 1 1/2" = 1'-0"
STEPS / HANDRAIL DETAIL
5 1 1/2" = 1'-0"
CORNER BOARD DETAIL
3 3" = 1'-0"
CHIMNEY DETAIL
4 1" = 1'-0"
UMDERPINNING DETAIL
6 1" = 1'-0"
ATTACHMENT 4
GRADE
B.O. BEAM
T.O. SLAB
+/- 4"
3
12
2
A504
6'-10"
+/- 9'-0"
3
12
ROOF MATERIAL OVER
ICE & WATER SHIELD,
SEE ELEVATIONS
EXTERIOR
ROOF SHEATHING
BEAM , SEE STRUCTURAL
5/4X TRIM OVER BLOCKING
HURRICANE CLIP @
EA. RAFTER
1X4 HARDIE TRIM
SISTERED ON EXPOSED
RAFTER TAILS
EXPOSED 2X8 ROOF FRAMING
@ 16" O.C., SEE STRUCTURAL
1X4 HARDIE
SOFFIT
METAL DRIP EDGE
P.T. 2X6
1'-0"
8"
1X TRIM ON UNDERSIDE OF BEAM
8"
1X4 CEILING
1/3
2/3
8X8
COLUMN
NOTE: PER CODE, RAFTER
NOTCH CANNOT EXCEED 25%
DEPTH OF RAFTER
5/4X TRIM OVER
BLOCKING
ADJUST HEIGHT AS NEEDED TO
ENSURE SOFFIT & FASCIA ALIGN W/
1 STORY GARAGE PORTION
A504
DETAILS
© 2020 PEARCE SCOTT ARCHITECTS
PEARCE
SCOTT
ARCHITECTS
6 STATE OF MIND ST
SUITE 200
BLUFFTON, SC 29910
843.837.5700
NEW RESIDENCE FOR:
KATE EAGEN
LOT 45 STOCK FARM
HISTORIC DISTRICT
BLUFFTON, SC 29910
DESCRIPTION / REVISION LOGNO. INITIALDATE
PROJECT NO. NO.
DATE 12.08.20
DRAWN BY AJD
CHECKED BY AWB
SHEET NO.
DO NOT SCALE FROM DRAWINGSNOT FOR CONSTRUCTION
24X36 PAPER SIZE
HPC CONCEPTUAL SUBMITTAL AJD10.14.20
HPC FINAL SUBMITTAL AJD12.08.20
COVERED CONNECTOR SECTION
1 1 1/2" = 1'-0"
EAVE DETAIL
2 1 1/2" = 1'-0"
ATTACHMENT 4
2X STUD WALL @ 16" O.C.
W/ THERMAL INSULATION
INTERIOR WALL FINISH
HEADER, SEE
STRUCTURAL
5/4X6 CASING
P.T. SHIM W/ THERMAL
INSULATION BETWEEN
SHIMS
JAMB CASING BEYOND
3
4"
2X CAP W/
CHAMFER
SEALANT
BETWEEN
FLASHING
AND CAP
3
4"
3
4"
2"
SIDING - REF.
ELEVATIONS
SEALANT UNDER FLASHING
WINDOW/DOOR,
SEE SCHEDULE
51
2"
EXTERIOR INTERIOR
WOOD CASING,
TBD BY OWNER
INTERIOR
EXTERIOR
31
2"
WINDOW/DOOR,
SEE SCHEDULE
WOOD SILL BELOW
SILL BELOW
P.T. SHIM W/ THERMAL INSULATION
B/W SHIMS
BACKER ROD AND SEALANT
MOISTURE BARRIER
EXTERIOR SHEATHING
SIDING - REF. ELEVATIONS
INTERIOR FINISH MATERIAL
1X CASING
2X STUD WALL @ 16" O.C.
W/ THERMAL INSULATION
5/4X4 TRIM
2X SILL PLATE
2X6 STUD WALL @ 16" O.C.
W/ THERMAL INSULATION
INTERIOR FINISH MATERIAL
BLOCKING
EXTERIOR INTERIOR
EXTERIOR SHEATHING
2X TRIM, CHAMFER
BACKER ROD AND SEALANT
11
2"
2"
WINDOW,
SEE SCHEDULE
EXTERIOR INTERIOR
1"
3
4"
SIDING - REF. ELEVATIONS
OPTIONAL SILL PAN, SEE
MANUFACTURER'S SPECIFICATIONS
SILL TRIM TBD BY OWNER
INTERIOR
EXTERIOR
4"INTERIOR WALL FINISH
1X CASING
EXTENSION JAMB
WOOD SILL BELOW
EXTERIOR SHEATHING
2X STUD
5/4X6 TRIM RIPPED TO 4"
SHIM W/ THERMAL INSULATION
BETWEEN SHIMS
CLAD WINDOW,
SEE SCHEDULE
SILL BELOW
BACKER ROD & SEALANT
3"
6"
INTERIOR FLOOR FINISH
P.T. SHIM
DOOR, SEE SCHEDULE
2X FLOOR FRAMING,
SEE STRUCTURAL
P.T. WOOD SILL
3"
13
4" 1
2"
METAL PAN FLASHING W/
END DAMS SET IN CONT.
BED OF SEALANT
2X FLOOR FRAMING,
SEE STRUCTURAL
WOOD DECKING
SLOPE TO DRAIN
5/4X OVER BLOCKING
2X SILL PLATE
2X6 STUD WALL @ 16" O.C.
W/ THERMAL INSULATION
INTERIOR FINISH MATERIAL
BLOCKING
EXTERIOR INTERIOR
EXTERIOR SHEATHING
CHAMFER 2X6 TRIM,
OVER BLOCKING
BACKER ROD AND SEALANT
51
2"
2"
WINDOW,
SEE SCHEDULE
EXTERIOR INTERIOR
1
2"
1
2"
SIDING - REF. ELEVATIONS
OPTIONAL SILL PAN, SEE
MANUFACTURER'S SPECIFICATIONS
SILL TRIM TBD BY OWNER
1
2
3
3" = 1'-0"
WINDOW HEAD - TYP
3" = 1'-0"
WINDOW SILL - TYP
3" = 1'-0"
WINDOW JAMB - TYP
4 3" = 1'-0"
WINDOW MULL - TYP
A505
WIN. & DOOR
DETAILS
5 3" = 1'-0"
DOOR SILL - TYP
NOTE: WINDOW / DOOR DETAILS BY WINDOSOR LEGEND SERIES.
SEE INSTALLATION DIAGRAM AND MANUFACTURER'S INSTALLATION
INSTRUCTIONS FOR FLASHING AND WATERPROOFING.
© 2020 PEARCE SCOTT ARCHITECTS
PEARCE
SCOTT
ARCHITECTS
6 STATE OF MIND ST
SUITE 200
BLUFFTON, SC 29910
843.837.5700
NEW RESIDENCE FOR:
KATE EAGEN
LOT 45 STOCK FARM
HISTORIC DISTRICT
BLUFFTON, SC 29910
DESCRIPTION / REVISION LOGNO. INITIALDATE
PROJECT NO. NO.
DATE 12.08.20
DRAWN BY AJD
CHECKED BY AWB
SHEET NO.
DO NOT SCALE FROM DRAWINGSNOT FOR CONSTRUCTION
24X36 PAPER SIZE
HPC CONCEPTUAL SUBMITTAL AJD10.14.20
HPC FINAL SUBMITTAL AJD12.08.20
6 3" = 1'-0"
6" WINDOW SILL
ATTACHMENT 4
A B C D
2'-8"
6'-0"
2'-8"
4'-6"
2'-8"
5'-0"
NOTE: VERIFY ALL SIZES, DIMENSIONS AND
ROUGH OPENING REQUIREMENTS WITH MANUFACTURER.
2'-8"
4'-0"
2 OVER 2
REMARKSDESCRIPTIONMANUF.MODEL NO.TYPE
WINDOW
HEAD SILL
A
DETAILS
FRAME SIZE
2'-8" X 6'-0"
JAMB MULL
NOMINAL
LITE CONFIG.
CLAD DOUBLE HUNG 1/A505 2/A505 3/A505
2'-8" X 4'-6"B
C*
2 OVER 2
D
MARVIN ELEVATE
2'-8" X 4'-0"
2'-8" X 5'-0" 2 OVER 2
NOTES:
1. DESIGN BASED ON MARVIN ELEVATE WINDOWS. (CLASSIC DOUBLE-HUNG & SIGNATURE CASEMENT). ALL WINDOWS & DOORS TO HAVE SIMULATED DIVIDED LITES WITH SPACER BARS (SDLS).
2. ALL WINDOWS ARE TO BE IMPACT-RATED OR CONTRACTOR TO INSTALL PERMANENT FASTENERS FOR HURRICANE PROTECTION AS REQUIRED BY CODE.
3. REFER TO MANUFACTURER'S SPECIFICATIONS FOR VARIOUS EXTERIOR WINDOW ROUGH OPENING REQUIREMENTS.
4. *VERIFY THAT SELECT WINDOWS MEET NATIONAL EGRESS CODES FOR FIRE EVACUATION. SILL TO BE MAX. 44" A.F.F. FOR EGRESS
5. ALL WINDOWS TO BE OPERABLE UNLESS OTHERWISE NOTED.
6. IF MANUFACTURER CHANGES, COORDINATE WITH ARCHITECT AS IT MAY HAVE AN IMPACT ON DESIGN.
7. IF WINDOWS ARE GROUPED, MAINTAIN MULL AS PER DETAIL.
CLAD DOUBLE HUNG
CLAD CASEMENT
CLAD CASEMENT 2 OVER 2
4/A505
1/A505 2/A505 3/A505 4/A505
1/A505
6 OR 2/A505
3/A505 4/A505
1/A505 3/A505 4/A505 6/A505 IN C.H. 2/A505 IN MAIN HOUSE
MARVIN ELEVATE
MARVIN ELEVATE
MARVIN ELEVATE
6/A505
NOTES:
1. REFER TO MANUFACTURER'S SPECIFICATIONS FOR VARIOUS INTERIOR AND EXTERIOR DOOR ROUGH OPENING REQUIREMENTS.
2. PROVIDE TEMPERED GLAZING AS REQUIRED BY CODE. SEE DOOR ELEVATIONS FOR LOCATIONS OF TEMPERED GLAZING IN DOORS.
3. POCKET DOORS TO HAVE FOUR WHEEL HEAVY DUTY TRACK ASSEMBLY BY JOHNSON HARDWARE.
4. DOOR STYLE TO BE SELECTED BY OWNER/CONTRACTOR.
REMARKSDESCRIPTIONTYPEROOM NAMEDOOR HEAD
DETAILS
JAMBSILLDOOR SIZE
NOMINAL
1/A505 SIM.
3/A505 SIM.001A
001C
002A
002B
002C
003A
GARAGE 9'-0" X 8'-0"OVERHEAD GARAGE DOOR
MATERIAL
FIR OR SIM. 5/A505 SIM.
003B
101A
H 6 LITE, 2 PANEL
001B GARAGE
GARAGE
STUDIO
9'-0" X 8'-0"OVERHEAD GARAGE DOORH
3'-0" X 8'-0"EXTERIOR OUTSWING DOORG 4 LITE, 1 PANEL (1/2 LITE)
3/A505 SIM.
3/A505 SIM.
6 LITE, 2 PANE
STUDIO
STUDIO
STUDIO BATH
STUDIO BATH
101B
101C
101D
103A
103B
103C
104A
105A
106A
107A
107B
109A
109B
200A
201A
201B
202A
202B
203A
203B
GREAT ROOM
GREAT ROOM
GREAT ROOM
GREAT ROOM
MUDROOM/LAUNDRY
MUDROOM/LAUNDRY
MUDROOM/LAUNDRY
POWDER
OWNER'S BEDROOM
OWNER'S WIC
OWNER'S BATH
OWNER'S BATH
SCREENED PORCH
SCREENED PORCH
STAIR HALL
BATH 2
BEDROOM 2
BATH 2
BEDROOM 2
BEDROOM 3
BEDROOM 3
EXTERIOR INSWING ENTRY DOOR
PAIR INTERIOR DOOR
INTERIOR DOOR
INTERIOR POCKET DOOR
INTERIOR POCKET DOOR
PAIR EXTERIOR OUTSWING DOOR (2) 3'-0" X 8'-0" 1/A505 SIM. 5/A505 3/A505 SIM. 6 LITE
FIR OR SIM.3'-0" X 7'-0" 1/A505 SIM. 5/A505 SIM. (4" STEP) 3/A505 SIM.J
MDF
MDF
MDF
MDF
(2) 2'-0" X 7'-0"
2'-8" X 7'-0"
PAIR EXTERIOR OUTSWING DOOR
PAIR EXTERIOR OUTSWING DOOR
PAIR EXTERIOR OUTSWING DOOR
(2) 3'-0" X 8'-0"
(2) 3'-0" X 8'-0"
(2) 3'-0" X 8'-0"
1/A505 SIM. 3/A505 SIM. 6 LITE
1/A505 SIM. 3/A505 SIM. 6 LITE
1/A505 SIM. 3/A505 SIM. 6 LITE
2'-4" X 7'-0"
2'-4" X 7'-0"
EXTERIOR INSWING DOORG 3'-0" X 8'-0" 1/A505 SIM. 3/A505 SIM.
F
K
M
L
L
MDFINTERIOR POCKET DOORD 3'-0" X 8'-0"
MDFINTERIOR POCKET DOORD 3'-0" X 8'-0"
MDFINTERIOR DOORD 3'-0" X 8'-0"
MDFINTERIOR DOORD 3'-0" X 8'-0"
INTERIOR DOOR MDF2'-4" X 8'-0"B
INTERIOR DOOR MDF2'-4" X 8'-0"B
INTERIOR POCKET DOOR MDF2'-4" X 8'-0"B
EXTERIOR SCREENED DOOR SCREENED DOOR1/A505 SIM.3'-0" X 7'-0"E 3/A505 SIM.FIR OR SIM.
EXTERIOR SCREENED DOOR SCREENED DOOR1/A505 SIM.3'-0" X 7'-0"E 3/A505 SIM.
B INTERIOR DOOR MDF2'-4" X 8'-0"
B INTERIOR DOOR MDF2'-4" X 8'-0"
B INTERIOR DOOR MDF2'-4" X 8'-0"
C INTERIOR DOOR MDF2'-8" X 8'-0"
B INTERIOR DOOR MDF2'-4" X 8'-0"
C INTERIOR DOOR MDF2'-8" X 8'-0"
B INTERIOR DOOR MDF2'-4" X 8'-0"
1/A505 SIM.
1/A505 SIM.COMPOSITE
COMPOSITE
5/A505
5/A505
5/A505
5/A505
POCKET
POCKET
POCKET
POCKET
POCKET
F
F
F
FIR OR SIM.
FIR OR SIM.
FIR OR SIM.
FIR OR SIM.
FIR OR SIM.
FIR OR SIM.
4 LITE, 1 PANEL (1/2 LITE)
4 LITE, 1 PANEL (1/2 LITE)
A C
8'-0"
3'-0"
FB
2'-4"
8'-0"
8'-0"
D
8'-0"
2'-8" 3'-0"
7'-0"
3'-0"
E 512"
512"
512"8"
T = TEMPERED
T
G
3'-0"
T
3'-0"
8'-0"
9'-0"
8'-0"
H J
3'-0"
T
3'-0"
7'-0"
K ML
2'-4"
7'-0"
7'-0"
2'-8"2'-0"
7'-0"
NOT USED
1 2 3 4
STEP STEP STEP STEP
MOISTURE BARRIER
MOISTURE BARRIER PEELED
UP WITH 45 DEGREE
SEAMS AT OPENING
S.A.F. OVER
MOISTURE BARRIER UNDER
NAILING FLANGE
(LEAVING FLANGE EXPOSED)
WRAP MOISTURE BARRIER
OVER TOP NAILING METAL FLASHING S.A.F. OVER
SEAMS OF MOISTURE
BARRIER AT TOP FLANGE
S.A.F. OVER NAILING
FLANGES AT JAMBS,
LAP OVER S.A.F. AT SILL
S.A.F. OVER
MOISTURE BARRIER
AT JAMBS
OPTIONAL SILL PAN W/ END DAMS,
SET IN CONTINUOUS BEAD OF SEALANT, SEE
WINDOW MANUFACTURER RECOMMENDATIONS NOTE: DETAILS SIMILAR @ DOOR HEAD AND JAMBS
CONTINUOUS BEAD OF SEALANT
BEHIND FLANGE AT HEAD
AND JAMBS
S.A.F. OVER NAILING
FLANGE AT HEAD,
LAP OVER S.A.F. AT JAMBS
METAL FLASHING OVER
S.A.F., SEALED AT TOP
W/ ADD. PIECE OF S.A.F.
A601
WIN. & DOOR
SCHEDULE
1/4" = 1'-0"
WINDOW ELEVATIONS
2
4 NTS
DOOR SCHEDULE
5 NTS
WINDOW SCHEDULE
1/4" = 1'-0"
DOOR ELEVATIONS
1
1/4" = 1'-0"
INSTALLATION DIAGRAM
3
© 2020 PEARCE SCOTT ARCHITECTS
PEARCE
SCOTT
ARCHITECTS
6 STATE OF MIND ST
SUITE 200
BLUFFTON, SC 29910
843.837.5700
NEW RESIDENCE FOR:
KATE EAGEN
LOT 45 STOCK FARM
HISTORIC DISTRICT
BLUFFTON, SC 29910
DESCRIPTION / REVISION LOGNO. INITIALDATE
PROJECT NO. NO.
DATE 12.08.20
DRAWN BY AJD
CHECKED BY AWB
SHEET NO.
DO NOT SCALE FROM DRAWINGSNOT FOR CONSTRUCTION
24X36 PAPER SIZE
HPC CONCEPTUAL SUBMITTAL AJD10.14.20
HPC FINAL SUBMITTAL AJD12.08.20
ATTACHMENT 4
DUPLEX OUTLET
GROUND FAULT CIRCUIT INTERUPTER
WEATHER-PROOF OUTLET
SWITCHED OUTLET
220 V. OUTLET
FLOOR OUTLET
CABLE T.V. JACK
TELEPHONE JACK
SURFACE MOUNTED CEILING FIXTURE
CHANDELIER
WALL FIXTURE
EXHAUST FAN
SWITCH
THREE-WAY SWITCH
FOUR-WAY SWITCH
FAN SWITCH
CEILING FAN
RECESSED FIXTURE
GARBAGE DISPOSAL
PENDANT
DIMMER SWITCH
ELECTRICAL LEGEND
DATA
WALL WASHER
GENERAL ELECTRICAL PLAN NOTES:
1. COORDINATE W/ OWNER ELECTRICAL ROUGH-IN
LOCATIONS PRIOR TO START OF ELECTRICAL WORK.
2. INSTALL SMOKE DETECTORS IN ACCORDANCE WITH
SECTION R313 (SMOKE ALARMS) OF THE INTERNATIONAL
RESIDENTIAL CODE.
3. COORDINATE THERMOSTAT LOCATIONS W/ OWNER AND
PER FINAL HVAC RETURN GRILLE LOCATIONS.
4. COORDINATE LANDSCAPE LIGHTS AND GAS LAMP
POST LOCATIONS W/ LANDSCAPE ARCHITECT.
5. COORDINATE METER SIZE WITH CONTRACTOR
WATER PROOF RECESSED FIXTURE
SLOPED RECESSED FIXTURE
UNDER COUNTER LIGHT
GAS LIGHT
SMOKE DETECTOR
FLOURESCENT LIGHT
GARAGE DOOR OPENER
JUNCTION BOX
METER - SIZE TBD BY CONTRACTOR
J
K-3429 MEMOIRS TOILETS VITREOUS CHINA
K-3429 MEMOIRS TOILETS VITREOUS CHINA
K-710 IRON WORKS
BATH KOHLER CAST IRON
CL
CL CL CL
CL
CLCL
CL
CL
CLCL
CL
CL
CL
CL
CL
CL
CL CL
CL
CL CL CL
CL
CL
CL
CL
CL
CL
CL
CL
EQ.EQ.
CL
EQ. EQ.
CL
TO LIGHTS &
SWITCH ABOVE J
CL
EQ. EQ.
CL
CL
D/W
REF
D
W
STEP LIGHTS
JAMB SWITCH
TO LIGHTS
ON C.H.
TO SWITCH @
GARAGE
FIRST FLOOR
ELEC. PLAN
1/4" = 1'-0"
FIRST FLOOR ELECTRICAL PLAN
1
E101
© 2020 PEARCE SCOTT ARCHITECTS
PEARCE
SCOTT
ARCHITECTS
6 STATE OF MIND ST
SUITE 200
BLUFFTON, SC 29910
843.837.5700
NEW RESIDENCE FOR:
KATE EAGEN
LOT 45 STOCK FARM
HISTORIC DISTRICT
BLUFFTON, SC 29910
DESCRIPTION / REVISION LOGNO. INITIALDATE
PROJECT NO. NO.
DATE 12.08.20
DRAWN BY AJD
CHECKED BY AWB
SHEET NO.
DO NOT SCALE FROM DRAWINGSNOT FOR CONSTRUCTION
24X36 PAPER SIZE
HPC CONCEPTUAL SUBMITTAL AJD10.14.20
HPC FINAL SUBMITTAL AJD12.08.20
SEE SHEET A104
ATTACHMENT 4
DUPLEX OUTLET
GROUND FAULT CIRCUIT INTERUPTER
WEATHER-PROOF OUTLET
SWITCHED OUTLET
220 V. OUTLET
FLOOR OUTLET
CABLE T.V. JACK
TELEPHONE JACK
SURFACE MOUNTED CEILING FIXTURE
CHANDELIER
WALL FIXTURE
EXHAUST FAN
SWITCH
THREE-WAY SWITCH
FOUR-WAY SWITCH
FAN SWITCH
CEILING FAN
RECESSED FIXTURE
GARBAGE DISPOSAL
PENDANT
DIMMER SWITCH
ELECTRICAL LEGEND
DATA
WALL WASHER
GENERAL ELECTRICAL PLAN NOTES:
1. COORDINATE W/ OWNER ELECTRICAL ROUGH-IN
LOCATIONS PRIOR TO START OF ELECTRICAL WORK.
2. INSTALL SMOKE DETECTORS IN ACCORDANCE WITH
SECTION R313 (SMOKE ALARMS) OF THE INTERNATIONAL
RESIDENTIAL CODE.
3. COORDINATE THERMOSTAT LOCATIONS W/ OWNER AND
PER FINAL HVAC RETURN GRILLE LOCATIONS.
4. COORDINATE LANDSCAPE LIGHTS AND GAS LAMP
POST LOCATIONS W/ LANDSCAPE ARCHITECT.
5. COORDINATE METER SIZE WITH CONTRACTOR
WATER PROOF RECESSED FIXTURE
SLOPED RECESSED FIXTURE
UNDER COUNTER LIGHT
GAS LIGHT
SMOKE DETECTOR
FLOURESCENT LIGHT
GARAGE DOOR OPENER
JUNCTION BOX
METER - SIZE TBD BY CONTRACTOR
J
K-3429
MEMOIRS TOILETS VITREOUS CHINA
KING
CL
CL
CL
CL
CL
CLCL
CLCL
STEP LIGHTS
REF
W/D
CL
CL
CL
EQ. EQ. EQ.
EQ. EQ.
CL
J
TO SWITCH @
MAIN HOUSE
TO SWITCH @
MAIN HOUSE
K-1123 ARCHER BATHING ACRYLIC
K-3429 MEMOIRS TOILETS VITREOUS CHINA
CL
CL CL
CLCLCL
CL
CL CL
CL
CL
CL
CL
CL
TO SWITCH
BELOW
SCND FLOOR
ELEC. PLAN
1/4" = 1'-0"
SECOND FLOOR ELECTRICAL PLAN
1
E102
© 2020 PEARCE SCOTT ARCHITECTS
PEARCE
SCOTT
ARCHITECTS
6 STATE OF MIND ST
SUITE 200
BLUFFTON, SC 29910
843.837.5700
NEW RESIDENCE FOR:
KATE EAGEN
LOT 45 STOCK FARM
HISTORIC DISTRICT
BLUFFTON, SC 29910
DESCRIPTION / REVISION LOGNO. INITIALDATE
PROJECT NO. NO.
DATE 12.08.20
DRAWN BY AJD
CHECKED BY AWB
SHEET NO.
DO NOT SCALE FROM DRAWINGSNOT FOR CONSTRUCTION
24X36 PAPER SIZE
HPC CONCEPTUAL SUBMITTAL AJD10.14.20
HPC FINAL SUBMITTAL AJD12.08.20
1/4" = 1'-0"
SECOND FLOOR ELECTRICAL PLAN
11/4" = 1'-0"
SECOND FLOOR ELECTRICAL PLAN
1
ATTACHMENT 4
PLANTING PLAN
L1
SUBMITTAL PLAN,
NOT FOR
CONSTRUCTION
DRAWING NUMBER
DRAWING TITLE
DESIGN CONCEPTS, DRAWING, SHEETS,
LOGOS, SPECIFICATIONS, DETAILS,
WRITTEN MATERIAL SHALL NOT BE USED
OR REPRODUCED IN WHOLE OR IN PART
IN ANY FORM WITHOUT PRIOR WRITTEN
CONSENT OF WJK LTD.
© 2020 WJK LTD.
THIS SHEET TO SCALE AT: 24"X36"
DATE:
PROJECT NO.:
DRAWN BY:
CHECKED BY:
DEC. 09, 2020
XXXXX.XX
JM
DK
REVISIONS:
SITE DEVELOPMENT PLANS
FOR
EAGEN RESIDENCE
STOCK FARM / BLUFFTON, SOUTH CAROLINA
GUILFORD PLACE / LOT 45
PLANTING REFERENCE NOTES:
1EXISTING TREES TO REMAIN.
EXISTING TREES TO BE REMOVED.
MULCH DISTURBED AREAS DUE TO CONSTRUCTION.
PROTECT AREA DRAIN FROM CLOGGING DURING INSTALLATION
OF PLANTS AND MULCH. MAINTAIN FUNCTIONALITY AND
POSITIVE PITCH TO DRAIN.
PRUNE TREE LIMBS CONFLICTING WITH HOUSE FRAMING.
2
4
3
5
010203040
5152535
Scale 1 " = 10'
c
N
E
W
RESIDENCE
CARRIAGE
HOUSE
GUILFORD PLACE
PROPERTY LINE
10' B.S.L.
10' B.S.L. PROPERTY LINE
PROPERTY LINE
25' B.S.L.
PROPERTY LINE
10' B.S.L.
1 LAGN
7 SPAB
5 ILLF
10 SPAB
1 HYDP
3 ILLF
1 HYDP
5 PODM
HERB GARDEN,
BY OWNER
3 ILVN
5 PERE
10 PERE
1 QUEV
1 OSMF
2 SABP
5 PODM
1 OSMF
1 PHIS
10 PLUA
10 PODP
1 CAMS
10 PERE
5 THEK
5 ALPZ
1 CAMS
5 THEK
3TYP.
1TYP.
2TYP.
4TYP.
5TYP.
PAVING SCHEDULE
SYMB.DESCRIPTION
2.1
CALL-
OUT
2.2
2.3
OYSTER SHELL WALK
TABBY CONCRETE APRON
2.4BRICK WALK / LANDING / PATIO
SPRING MIX GRAVEL DRIVE
NABRICK BORDERS
NOTE: MATERIAL SYMBOLS / HATCHES ARE GRAPHIC IN NATURE AND ARE NOT INTENDED
TO BE TO SCALE. REFER TO SITE DETAILS AND LAYOUT PLANS FOR SIZES AND DIMENSIONS.
SITE DETAILS LEGEND
DESCRIPTION
9.1
CALL-
OUT
7.1LIVING FENCE
FIRE PIT
7.2GATE
2.3
2.1
2.4
2.2
9.1
7.2
7.1
SOD
SOD
SOD
SOD
SOD
PLANT SCHEDULE:
TREE CANOPY COVERAGE:
CANOPY COVERAGE SUMMARY
COVERAGE (SF) DESCRIPTION
SITE AREA
BUILDING FOOTPRINT
REMAINING SITE AREA
MATURE CANOPY COVERAGE
PROVIDED
(EXISTING AND PROPOSED)
10,952
3,128
7,824
5,839
% CANOPY COVERAGE (75% MIN.)75%
CANOPY COVERAGE
OF EXISTING AND
PROPOSED TREES
(GREEN SHADED AREA)
1 SABP (OPTIONAL)
5 ILVN
5 ILVN
ATTACHMENT 5
PLAN REVIEW COMMENTS FOR COFA-10-20-014673
Town of Bluffton
Department of Growth Management
20 Bridge Street P.O. Box 386 Bluffton, South Carolina 29910
Telephone 843-706-4522
OLD TOWN
Plan Type: Apply Date:
Plan Status: Plan Address: 5718 Guilford Pl Place
BLUFFTON, SC 29910
Historic District
Active
10/15/2020
Plan PIN #:Case Manager: R610 039 00A 0396 0000Katie Peterson
Plan Description: A request by Pearce Scott Architects, on behalf of owner, Kate Eagen, for review of a Certificate of
Appropriateness Application to allow for the construction of a new single-family residential structure of
approximately 2,117 SF and a Carriage House of approximately 1,172 SF located at 5718 Guilford Place,
identified as Lot 45 in the Stock Farm Development, in the Old Town Bluffton Historic District and zoned
Neighborhood General – HD.
STATUS 10-27-2020: The application is currently being reviewed by Staff for conformance with the Unified
Development Ordinance (UDO), Traditional Construction Patterns, and any development plans associated
with the parcel and is scheduled for review by the HPRC at the November 2, 2020 meeting.
Staff Review (HD)
Submission #: 1 Recieved: 10/15/2020 Completed: 10/30/2020
Reviewing Dept. Complete Date StatusReviewer
Approved with Conditions10/30/2020Building Safety Review Richard Spruce
Comments:
15 Oct 2020 - RAS
Guardrails may be required for all porches. The porches show an elevation of 30-inches in these drawings. The International
Residential Code (IRC), 2018 Edition, section 312.1.1 states that guardrails are required where the walking surfaces are over
30-inches above grade measured 36-inches out from the open edge of the walking surface. Insect screening shall not be
considered as a guard.
So it depends on final grade before we can tell if the guardrails will be required. Of course there is another section that states
grading shall be away from the foundation at 6-inches in the first 10-feet (IRC 401.3). With this being said it appears that 3 feet away
from the porch the drop will exceed 30-inches, therefore guardrails will be required.
Approved with Conditions10/30/2020Growth Management Dept Review
(HD)
Katie Peterson
Comments:
1. For the Final submittal, a letter of approval from the Stock Farm HARC is required. (Applications Manual)
2. In keeping with masonry building technology, metal spark arrestors, exposed metal flies, or pre-fabricated chimney capos are
not permitted. The proposed chimney shows a metal chimney cap. Revise the chimney cap to a permitted material or provide
additional information for HPC review and determination on the appropriateness of a material not specifically listed in the UDO.
(UDO Section 5.15.6.E.8.d.)
3. The UDO requires that porch posts shall be spaced no farther apart than they are tall. Columns are proposed as further apart on
center than they are tall at the corner bay (11'1") on the front elevation and the side porch (10'6"). The porch post placement must
be revised to meet this requirement. (UDO Section 5.15.6.H.1.a. and Traditional Construction Patterns Section 52)
4. Metal roofs are permitted to have a 5-V or Standing Seam profile. The plans and application note the roof to be metal, but do not
specify what profile will be used. Provide additional information on the metal roof profile.
5.For the final application provide a landscape plan noting foundation plantings, street tree locations, canopy coverage, and any
landscaping proposed for buffering; as well provide architectural details of the railing and baluster, a typical window detail, corner
board/pilaster trim detail, water table detail, screen porch detail, and sections through the eave and wall depicting the material
configuration and dimensions. (Applications Manual)
6. A tree removal permit is required for the removal of any tree on a single-family residential lot that measures 14" in DBH or greater.
A few of the trees on the site proposed for removal exceed 14" in DBH. As such, a tree removal permit is required.
Approved with Conditions10/30/2020Watershed Management Review William Baugher
Comments:
10/30/2020 Page 1 of 2
ATTACHMENT 6
1. Small Construction Activities, The Town will require a Stormwater Affidavit with a SC DHEC NOI form D-0451 and implementation
of the Construction Site BMPs found in Chapter 9 of the Stormwater Design Manual and the SCDHEC Erosion and Sediment
Reduction standards and other Stormwater Management regulations, where applicable before Building Permits will be issued.
Approved10/30/2020Beaufort Jasper Water and Sewer
Review
James Clardy
Approved10/30/2020HPRC Review Katie Peterson
Comments:
1. Thank you for providing well dimensioned and wholly visible plans with your submittal.
Approved10/30/2020Transportation Department Review
- HD
William Howard
Approved10/22/2020Addressing Review Nick Walton
Comments:
1. No comment.
Plan Review Case Notes:
10/30/2020 Page 2 of 2
ATTACHMENT 6
STOCK FARM DEVELOPMENT
BOX 2570
BLUFFTON, SC 29910
15 December 2020
To: Katie Peterson, Town of Bluffton
Subject: HPC Review of Stock Farm Applications
Katie—It is understood that the HPC, in January, will review plans from two applicants and Stock Farm
property owners:
-----Romski-5806 Guilford Place (Lot 20A)—Carriage House Additions
-----Eagen-5718 Guilford Place (Lot 45)—Personal Residence
Stock Farm has reviewed the plans and found these to meet the community requirements. It is
recommended that these plans be granted a Certificate of Appropriateness.
Emmett McCracken
Manager
ATTACHMENT 7
20 Meriwether Court, Lot 3 – Certificate of Appropriateness Historic Preservation Commission
HISTORIC PRESERVATION
COMMISSION
STAFF REPORT
Department of Growth Management
MEETING DATE: January 6, 2021
PROJECT: Lot 3, 20 Meriwether Court – New Construction:
Single-Family Residential
APPLICANT: Webb Construction
PROJECT MANAGER: Katie Peterson, AICP, Senior Planner
APPLICATION REQUEST: The Applicant, Webb Construction, on behalf of Ernie
Suozzi, requests that the Historic Preservation Commission approve the following
application:
1. COFA-10-20-014694. A Certificate of Appropriateness to allow the
construction of a 1.5-story single-family residential structure of
approximately 1,954 SF and a 1-story Carriage House of approximately 352
SF located at 20 Meriwether Court, Lot 3 in the Landen Oaks Development in
the Old Town Bluffton Historic District, and zoned Neighborhood General-HD.
INTRODUCTION: The Applicant is proposing the construction of a detached single-
family residence located in the Old Town Bluffton Historic District. The proposed
building, of approximately 1,954 SF, has similar attributes of the Village House, but
is not 2 stories in height, so it is reviewed as an Additional Building Type in
accordance with the allowable building types for the Neighborhood General-HD
zoning district. In addition to the primary structure, the Applicant is proposing a
Carriage House structure of approximately 352 SF, which meets the design
standards for a Carriage House Building Type. This lot is located within the Landen
Oaks development plan, which was approved in April of 2019 (COFA-07-15-
009290), which specifies that the setbacks must meet those found in the Unified
Development Ordinance.
The main house structure is under a two-story forward-facing gable with side-facing
gable projection to the left. It features a front porch under a hip roof and a small
rear porch under the same. The second story porch on the rear elevation has a
trellis detail rather than a roof. The proposed materials include combination of
horizontal lap siding on most of the house with vertical board and batten in the
gabled ends. The gable ends also unique trim detailing and a round window. It has
a 5V metal roof. The Carriage House features similar materials and trim detailing
as the primary structure. It is one-story in height and has a forward facing gable
roof.
January 6, 2021 Page 2
20 Meriwether Court, Lot 3 – Certificate of Appropriateness Historic Preservation Commission
This project was presented to the Historic Preservation Review Committee for
conceptual review at the November 16, 2020 meeting and comments were provided
to the Applicant (See attachment 5).
HISTORIC PRESERVATION COMMISSION ACTIONS: As granted by the powers and
duties set forth in Section 2.2.6.E.2, the Historic Preservation Commission has the
authority to take the following actions with respect to this application:
1. Approve the application as submitted by the Applicant;
2. Approve the application with conditions; or
3. Deny the application as submitted by the Applicant.
It is important to note that the intent of Section 5.15 Old Town Bluffton Historic
District of the Unified Development Ordinance (UDO) is that the Section be user
friendly and informative to the residents and the members of HPC and is not
intended to discourage creativity or force the replication of historic models. Rather,
it is to set forth a framework in which the diversity that has always characterized
Bluffton can continue to grow. The Section also defines guidelines for design and
materials similar to that used on structures within the Old Town, and it is the
charge of the HPC to assess the interpretation of these guidelines as they pertain to
applications using the established review criteria.
REVIEW CRITERIA & ANALYSIS: Town Staff and the Historic Preservation
Commission are required to consider the criteria set forth in Section 3.18.3 of the
UDO in assessing an application for a Certificate of Appropriateness – Historic
District (HD). The applicable criteria are provided below followed by a Staff
Finding(s) based upon review of the application submittals to date.
1. Section 3.18.3.B. Consistency with the principles set forth in the Old Town
Master Plan.
a. Finding. The application is consistent with the principles set forth in the
Old Town Master Plan. The Old Town Master Plan states that, “The built
environment, in particular the historic structures scattered throughout Old
Town, should be protected and enhanced. While it is of great importance
to save and restore historic structures, it is just as important to add to the
built environment in a way that makes Old Town more complete.”
The Applicant proposes to construct a new single-family residence and
Carriage House within the Old Town Bluffton Historic District, a locally and
nationally designated historic district. The buildings have been designed
to be sympathetic to the architectural character of the neighboring
historic structures, so their addition to the architectural diorama will both
protect the integrity of the existing historic structures and enhance the
neighborhood by adding architectural variety.
b. Finding. The Old Town Master Plan initiatives also include the adoption of
a form-based code that included architectural standards for structures
located within the Old Town Bluffton Historic District. These standards
are included in Article 5 of the UDO. The new construction proposed as
January 6, 2021 Page 3
20 Meriwether Court, Lot 3 – Certificate of Appropriateness Historic Preservation Commission
part of this request will be in conformance with those standards if the
conditions noted in item 2 of this Section are met.
c. Finding. The Old Town Master Plan initiatives also promote preservation
and protection of the legacy of the Old Town Bluffton Historic District
through additions to the built environment which make Old Town more
complete. The addition of the proposed residential structure and Carriage
House add to the district as well as help provide completeness to the
neighborhood and overall district.
2. Section 3.18.3.C. The application must be in conformance with applicable
provisions provided in Article 5, Design Standards.
a. Finding. Town Staff finds that the design of the primary structure falls
within the category of Additional Building Type as allowed in the
Neighborhood General Historic District per Section 5.15.5.C. Additional
Building Types are permissible. As has been past practice, the Town Staff
requests the Historic Preservation Commission review and make a final
recommendation regarding the appropriateness of the Additional Building
Type.
b. Finding. Town Staff finds that if the conditions noted below are met, the
proposed addition will be in conformance with applicable provisions
provided in Article 5:
1) Section 5.15.6.A&I. Windows and Doors. Windows shall be square
or rectangle. The plans show a decorative round window in the
gable on the front and rear elevation. Per Section 5.15.6.A. of the
UDO, the UDO Administrator, or in this case the HPC as the
approval authority for a COFA, has the authority to allow
substitute materials for those listed in the UDO, when it is
appropriate. The applicant is requesting a determination on the
appropriateness of the use of a round window as a substitute for
those listed in Section 5.15.6.I of the UDO.
2) Section 5.15.6.H. Columns. Columns shall be spaced no further
apart than they are tall. The columns on the second-story porch,
at the back of the house on the left elevation are approximately
11’ apart and 8 feet tall. An additional column must be added or
the columns reconfigured to be spaced no farther apart than they
are tall in this location.
3) Section 5.15.5.C. Neighborhood General -HD Permitted Building
Types. This structure has been designed as an Additional Building
Type and meets the setbacks for an additional building type. It
has all of the characteristics of a Village House, but the square
footage listed falls within the half story definition. There appears
to be a significant amount of space in the ‘Attic’ which should be
January 6, 2021 Page 4
20 Meriwether Court, Lot 3 – Certificate of Appropriateness Historic Preservation Commission
included in the square footage calculations as it meets has the
required head height as defined in Article 9 of the UDO. A half-
story is defined as a space under a sloping roof that has the line of
intersection of the roof and the exterior wall supporting the roof
not more than 3 feet above the floor level, and in which space the
possible floor area with head room of 5 feet or more occupies
between 30 and 70 percent of the total floor area of the story
directly beneath. Additional information regarding the possible
floor area with head room of 5 feet or more must be provided for
review.
Should the revised square-footage calculations exceed 70 percent
of the story beneath it, the structure would be identified as a
Village House and the setbacks would need to be revised to have a
10’-15’ front build-to, 15’ side setbacks and a 30’ rear setback.
Alternately, the roof line may be lowered to reduce the amount of
space with the possible floor area with head room of 5 feet or
more to be within the 30 to 70 percent area of the floor beneath.
4)
3. Section 3.18.3.D. Consistency with the nature and character of the
surrounding area and consistency of the structure with the scale, form and
building proportions of the surrounding neighborhood.
Finding. Town Staff finds the nature and character of the new construction
to be consistent and harmonious with that of the surrounding neighborhood.
The mass and scale of the structure is appropriate for its location and the
architectural detailing is sensitive to the neighboring properties.
4. Section 3.18.3.F. The historic, architectural, and aesthetic features of the
structure including the extent to which its alteration or removal would be
detrimental to the public interest.
Finding. The Applicant seeks approval for the construction of new structures
in the Old Town Bluffton Historic District. The proposed plans are
sympathetic in design to the neighboring historic and non-historic resources;
therefore, the structure, as proposed, will have no adverse effect on the
public interest.
5. Section 3.18.3.H. The application must comply with applicable requirements
in the Applications Manual.
Finding. The application has been reviewed by Town Staff and has been
determined to be complete.
STAFF RECOMMENDATION: It is the charge of the HPC to assess and interpret the
standards and guidelines set forth in the UDO as they pertain to applications using
the review criteria established in the UDO and to take appropriate action as granted
January 6, 2021 Page 5
20 Meriwether Court, Lot 3 – Certificate of Appropriateness Historic Preservation Commission
by the powers and duties set forth in Section 2.2.6.E.2. Town Staff finds that with
the conditions noted below, the requirements of Section 3.18.3 of the Unified
Development Ordinance have been met and recommends that the Historic
Preservation Commission approve the application with the following conditions:
1. Per Section 5.15.6.A. and 5.15.6.I. The applicant is requesting a
determination on the appropriateness of the use of a round window as a
substitute for those listed in the UDO.
2. Per Section 5.15.6.H. of the UDO, columns must be reconfigured to be
spaced no farther apart than they are tall on the second-story porch, at
the back of the house on the left elevation.
3. Per Section 5.15.5.C. The second-floor square footage must be updated,
and additional information must be provided regarding the possible floor
area with head room of 5 feet or more.
4. Per Section 5.15.5.C. If the square footage exceeds 70% of the floor
beneath, the setbacks must be revised to meet the Village House
setbacks.
ATTACHMENTS:
1. Location Map
2. Zoning Map
3. Application & Applicant Narrative
4. Site Plan & Elevations
5. Landscape Plan
6. HPRC Report
7. HOA Approval Letter
8. Chimney Cap Detail
20 Meriwether Ct, Lot 3: Location Map
1 2 / 2 1 / 2 0 2 0
0 0 . 0 3 0 . 0 5 0 . 0 8 0 . 1 0 . 1 30 . 0 1
m i
F
ATTACHMENT 1
20 Meriwether Ct, Lot 3: Zoning Map
1 2 / 2 1 / 2 0 2 0
0 0 . 0 3 0 . 0 5 0 . 0 8 0 . 1 0 . 1 30 . 0 1
m i
F
O v e r r id e 1
P a r c e l P r o p e r t y L in e s
ATTACHMENT 2
TOWN OF BLUFFTON Growth Management Customer Service Center
CERTIFICATE OF APPROPRIATENESS- OLD TOWN BLUFFTON
HISTORIC DISTRICT (HD) APPUCATION
20 Bridge Street
Bluffton, SC 29910
(843)706-4522
www.townofbluffton.sc.gov
applicationfeedback@townofbluffton.com
Applicant Property Owner
Name: Webb Construction/ Brian Webb Name: Ernie Suozzi
Phone: 843-247-7883 Phone: 843-422-0564
Mailing Address: 365 Red Cedar St. Ste 404 Mailing Address: 6 Mossy Oaks Lane
Bluffton, SC 29910 Hilton Head Is. SC 29926
E-mail: webbconstruction96@gmail.com E-mail:
athsoccer1@gmail.com
Town Business License# (if applicable): UC- 06-20-033549
Project Information (tax map info available at http://www.townofbluffton.us/gis/)
Project Name: 20 Meriwether Court
Project Location: Landen Oaks Development
Zoning District: Neighborhood General - HD
Conceptual: I Final: D I Amendment: D
Application for:
� New Construction
Acreage: .1340 □ Renovation/Rehabilitation/ Addition
Tax Map Number(s): □ Relocation or Demolition
Project Description: New residential home with a detached garage
Minimum Requirements for Submittal
□ 1. Full sized copies and digital files of the Site Plan(s). One (1) set for Conceptual, two (2) sets for Final
□ 2. Full sized copies and digital files of the Architectural Plan(s). One (1) set for Conceptual, two (2) sets for Final
□ 3. Project Narrative describing reason for application and compliance with the criteria in Article 3 of the UDO.
□ 5. All information required on the attached Application Checklist.
□ 6. An Application Review Fee as determined by the Town of Bluffton Master Fee Schedule. Checks made payable
to the Town of Bluffton.
Note: A Pre-Application Meeting is required prior to Application submittal.
Disclaimer: The Town of Bluffton assumes no legal or financial liability to
the
applicant or any
third party whatsoever by approving the plans associated with this permit.
I hereby acknowledge by my signature below that the foregoing application is complete and accurate and that I am
the owner of the subject property. As applicable, I authorize 9'e subject property to be posted and inspected.
Property Owner Signature: I? /'--vJ1-1 �-
)
1671 Date: I ) ( � I IA-/))�
Applicant Signature: R""'
- ·-
Date: \ \ I 4 I �o,... ,.
For Office Use
Application Number: Date Received:
Received By: Date Approved:
Town of Bluffton Certificate of Appropriateness-Historic District Application Last Updated: 4/8/2014
v)
ATTACHMENT 3
TOWN OF BLUFFTON
CERTIFICATE OF APPROPRIATENESS - HISTORIC DISTRICT
PROJECT ANALYSIS
In accordance with the Town of Bluffton Unified Development Ordinance (UDO), the following information shall
be included as part of a Certificate of Appropriateness application submitted for review by the Historic
Preservation Commission (HPC) and the Historic Preservation Review Committee. The use of this checklist by
Town Staff or the Applicant shall not constitute a waiver of any requirement contained in the UDO.
1. DESIGN REVIEW PHASE CONCEPTUAL REVIEW
FINAL REVIEW I
2. SITE DATA
Identification of Proposed Building Type (as defined in Article 5): Add i t io n al b uil d i n g typ e
Building
Main Structure
Ancillary
Ancillary
4. SITE COVERAGE
I Rear: 25
Description
(Main House, Garage, carriage
House, etc.)
Main House
Garage
Impervious Coverage
Building Footprint(s)
Impervious Drive, Walks & Paths
Open/Covered Patios
A.TOTAL IMPERVIOUS COVERAGE
B.TOTAL SF OF LOT
% COVERAGE OF LOT (A/B= %)
5. BUILDING MATERIALS
Building Element Materials, Dimensions,
and Operation
Foundation Block
Walls Hardie
Roof Metal
Chimney Stucco
Trim 2x4
Water table 2 x ripped w/ 2x12
Corner board 2x6
Railings 2x4 p.t
Balusters 2x2
Handrails 2x4 p.t
Building Setbacks Front: 10 Rt. Side: 10
3. BUILDING DATA
Lt. Side: 10
Existing Square Proposed Square
Footage Footage
1954
352
Coverage (SF)
2306
0
270
2576
5837
44%
Building Element Materials, Dimensions,
and Operation
Columns Wod
Windows Vinyl
Doors Wood
Shutters N/A
Skirting/Underpinning 5/4 p.t
Cornice, Soffit, Frieze Hardie
Gutters N/A
Garage Doors Metal/ Aluminum
N/A Green/Recycled Materials
Last Updated: 4/8/2014
ATTACHMENT 3
ATTACHMENT 3
New Single-Family Residence –
- Two story 1954 heated sqft
- Detached garage
- No Trusses
- Block foundation
- Hardie Siding
ATTACHMENT 3
ATTACHMENT 4
ATTACHMENT 4
ATTACHMENT 4
ATTACHMENT 4
ATTACHMENT 4
ATTACHMENT 4
ATTACHMENT 4
ATTACHMENT 4
ATTACHMENT 4
ATTACHMENT 4
& Engineering, Inc.
www.sci-engng.com
Bus(843) 718-2525
Goose Creek, South Carolina
105 Central Ave 200-B
Structural Engineering
Fax (843) 718-2776
SOUTHERNCONSULTINGINC.ANDENGINEERING,
Southern Consulting
Suozzi Residence
20 Merriweather Court
Bluffton, SC
Oct 29, 2020
ATTACHMENT 4
& Engineering, Inc.
www.sci-engng.com
Bus(843) 718-2525
Goose Creek, South Carolina
105 Central Ave 200-B
Structural Engineering
Fax (843) 718-2776
SOUTHERNCONSULTINGINC.ANDENGINEERING,
Southern Consulting
Suozzi Residence
20 Merriweather Court
Bluffton, SC
Oct 29, 2020
ATTACHMENT 4
& Engineering, Inc.
www.sci-engng.com
Bus(843) 718-2525
Goose Creek, South Carolina
105 Central Ave 200-B
Structural Engineering
Fax (843) 718-2776
SOUTHERNCONSULTINGINC.ANDENGINEERING,
Southern Consulting
Suozzi Residence
20 Merriweather Court
Bluffton, SC
Oct 29, 2020
ATTACHMENT 4
✱
✱
✱
✱ ✱
✱
✱
✱
✱ ✱
PLANTING PLAN
L1
SUBMITTAL PLAN
NOT FOR
CONSTRUCTION
DRAWING NUMBER
DRAWING TITLE
DESIGN CONCEPTS, DRAWING, SHEETS,
LOGOS, SPECIFICATIONS, DETAILS,
WRITTEN MATERIAL SHALL NOT BE USED
OR REPRODUCED IN WHOLE OR IN PART
IN ANY FORM WITHOUT PRIOR WRITTEN
CONSENT OF WJK LTD.
© 2020 WJK LTD.
THIS SHEET TO SCALE AT: 24"X36"
DATE:
PROJECT NO.:
DRAWN BY:
CHECKED BY:
DEC. 1, 2020
200XX.01
CB
DK
REVISIONS:
SITE DEVELOPMENT PLANS
FOR
SUOZZI RESIDENCE
BLUFFTON, SOUTH CAROLINA
20 MARIWETHER COURT / LOT 3
PLANT SCHEDULE
08162432
4122028
Scale 1" = 8'
c
N
E W
LOT 45
STOCK FARM RD.
OPEN
SPACE
& R/W
LOT 4
PARCEL
225
PERE
2 SABP
3 TRAJ
3 ILLF
3 PODP
5 PODM
SOD
GRAVEL
DRIVE
TABBY LANDING
5 PODP
1 PHIS
3 PODP
1 LIVC
100 OPHJ
1 CERC
3 HYDM
5 AZAF
5 BUXM
TABBY LANDING
3 MUHC
3 MUHC
1 HYDP
3 PODM
5 PODM
2 TRAJ
TABBY APRON
1 CAMS
50 OPHJ
15 OPHJ
1 CAMS
1 CAMS
5 BUXM
MULCH
DISTURBED
AREAS, TYP.
EXISTING TREE TO
REMAIN, TYP.
TABBY STEPPING
STONES TO BE
COORDINATED WITH
DOOR LOCATION
SYRUP KETTLE FIRE
PIT
GRAVEL
TABBY LANDING
TABBY STEPPING
STONES, TYP.
1 CAMJ
1 QUEV
1 OSMF
TREE CANOPY COVERAGE
CANOPY COVERAGE SUMMARY
COVERAGE (SF) DESCRIPTION
SITE AREA
BUILDING FOOTPRINT
REMAINING SITE AREA
MATURE CANOPY COVERAGE
PROVIDED
(EXISTING AND PROPOSED)
5820
1942
3878
3130
% CANOPY COVERAGE (75% MIN.)81%
CANOPY COVERAGE
OF EXISTING AND
PROPOSED TREES
(GRAY SHADED AREA)
ATTACHMENT 4
✱
✱
✱
✱ ✱
✱
✱
✱
✱ ✱
PLANTING PLAN
L1
SUBMITTAL PLAN
NOT FOR
CONSTRUCTION
DRAWING NUMBER
DRAWING TITLE
DESIGN CONCEPTS, DRAWING, SHEETS,
LOGOS, SPECIFICATIONS, DETAILS,
WRITTEN MATERIAL SHALL NOT BE USED
OR REPRODUCED IN WHOLE OR IN PART
IN ANY FORM WITHOUT PRIOR WRITTEN
CONSENT OF WJK LTD.
© 2020 WJK LTD.
THIS SHEET TO SCALE AT: 24"X36"
DATE:
PROJECT NO.:
DRAWN BY:
CHECKED BY:
DEC. 1, 2020
200XX.01
CB
DK
REVISIONS:
SITE DEVELOPMENT PLANS
FOR
SUOZZI RESIDENCE
BLUFFTON, SOUTH CAROLINA
20 MARIWETHER COURT / LOT 3
PLANT SCHEDULE
08162432
4122028
Scale 1" = 8'
c
N
E W
LOT 45
STOCK FARM RD.
OPEN
SPACE
& R/W
LOT 4
PARCEL
225
PERE
2 SABP
3 TRAJ
3 ILLF
3 PODP
5 PODM
SOD
GRAVEL
DRIVE
TABBY LANDING
5 PODP
1 PHIS
3 PODP
1 LIVC
100 OPHJ
1 CERC
3 HYDM
5 AZAF
5 BUXM
TABBY LANDING
3 MUHC
3 MUHC
1 HYDP
3 PODM
5 PODM
2 TRAJ
TABBY APRON
1 CAMS
50 OPHJ
15 OPHJ
1 CAMS
1 CAMS
5 BUXM
MULCH
DISTURBED
AREAS, TYP.
EXISTING TREE TO
REMAIN, TYP.
TABBY STEPPING
STONES TO BE
COORDINATED WITH
DOOR LOCATION
SYRUP KETTLE FIRE
PIT
GRAVEL
TABBY LANDING
TABBY STEPPING
STONES, TYP.
1 CAMJ
1 QUEV
1 OSMF
TREE CANOPY COVERAGE
CANOPY COVERAGE SUMMARY
COVERAGE (SF) DESCRIPTION
SITE AREA
BUILDING FOOTPRINT
REMAINING SITE AREA
MATURE CANOPY COVERAGE
PROVIDED
(EXISTING AND PROPOSED)
5820
1942
3878
3130
% CANOPY COVERAGE (75% MIN.)81%
CANOPY COVERAGE
OF EXISTING AND
PROPOSED TREES
(GRAY SHADED AREA)
ATTACHMENT 5
PLAN REVIEW COMMENTS FOR COFA-10-20-014694
Town of Bluffton
Department of Growth Management
20 Bridge Street P.O. Box 386 Bluffton, South Carolina 29910
Telephone 843-706-4522
OLD TOWN
Plan Type: Apply Date:
Plan Status: Plan Address: 20 Meriwether Ct Court
BLUFFTON, SC 29910
Historic District
Active
10/21/2020
Plan PIN #:Case Manager: R610 039 00A 0390 0000Katie Peterson
Plan Description: A request by Brian Webb, on behalf of owner, Ernie Suozzi, for review of a Certificate of Appropriateness
Application to allow the construction of a new 1 ½ story single family residence of approximately 1,955 SF
and a Carriage House of approximately 352 SF to be located at 20 Meriweather Court, in the Landon Oaks
development, in the Old Town Bluffton Historic District and zoned Neighborhood General – HD.
STATUS [11-4-2020]: The application is currently being reviewed by Staff for conformance with the Unified
Development Ordinance (UDO), Traditional Construction Patterns, and any development plans associated
with the parcel and is scheduled for review by the HPRC at the November 16, 2020 meeting.
Staff Review (HD)
Submission #: 1 Recieved: 10/29/2020 Completed: 11/13/2020
Reviewing Dept. Complete Date StatusReviewer
Approved with Conditions11/09/2020Building Safety Review Richard Spruce
Comments:
9 Nov 20 - RAS
The plans do not show the height of the porches. They only state equal with the finished first floor. Guardrails may be required
depending on the height of the porches above grade that is within 36 inches of the walking surface of the porch.
Approved with Conditions11/13/2020Growth Management Dept Review
(HD)
Katie Peterson
Comments:
1. The application identifies the structure as a Village House building type. While it has characteristics of a Village House, it is 1.5
stories rather than 2 and would therefore be reviewed as an Additional Building type. (UDO 5.15.5.C.)
2. The site plan shows the structure located at 5' from the left side, 26.7' from the rear, and 17.9' from the front property line. As an
Additional Building type, the required setbacks are: Front 10'-20', Side 10', Rear 25'. (UDO5.15.5.C.)
3. For final submittal, a letter of approval from the POA is required as it is located in the Landen Oaks development. (Applications
Manual)
4. The elevations show an attached garage while the site plan shows a detached garage. As a detached garage, the elevations
must be updated to show the rear elevation where the connection will not be as not enough information was provided to complete
the review.
5. Additional information on the finished floor height and porch height must be provided for review. Finished First Floor height is
required to be a minimum of 3' above average adjacent sidewalk grade. (UDO 5.15.5.F.) Porch height is required to be a minimum
of 30" from adjacent grade.
6. The porch section detail and garage wall section show the use of plywood in the soffit. Rough sawn wood, plywood, and
aluminum are not permitted as soffit materials. The soffit material must be revised to a permitted material.
7. In keeping with masonry building technology, metal spark arrestors, exposed metal flies, or pre-fabricated chimney capos are not
permitted. The proposed chimney shows is unclear about the proposed chimney cap. Provide additional information regarding the
chimney cap material and configuration. (UDO Section 5.15.6.E.8.d.)
8. At time of final submittal, provide a Landscape Plan showing foundation plantings, street trees and canopy coverage.
(Applications Manual)
9. The UDO requires that porch posts shall be spaced no farther apart than they are tall. Columns are proposed as further apart on
center than they are tall on the right side rear porch on the first and second story and the left side elevation on the second story. The
porch post placement must be revised to meet this requirement. (UDO Section 5.15.6.H.1.a. and Traditional Construction Patterns
Section 52)
10. The UDO states that driveways shall be a maximum of 10 feet wide in front of the principal plane of the buildings. The plans
show a 12 foot wide drive. Reduce the drive width to no more than 10 feet in width. (UDO Section 5.157.H.2.)
11/13/2020 Page 1 of 2
ATTACHMENT 6
Approved11/10/2020Beaufort Jasper Water and Sewer
Review
James Clardy
Comments:
1. No comment.
Approved11/13/2020HPRC Review Katie Peterson
Comments:
1. No comment.
Approved11/13/2020Transportation Department Review
- HD
William Howard
Comments:
1. No Comment.
Approved11/12/2020Watershed Management Review William Baugher
Comments:
1. No Comment.
Approved11/05/2020Addressing Review Nick Walton
Comments:
1. No Comment.
Plan Review Case Notes: