RecordWell Data

Historic Preservation Review Commission (PDF)

Town of Bluffton · Beaufort County · meeting of Jan 6, 2021 · Agendas

Open the original document More from Town of Bluffton

Text

Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.

TOWN OF BLUFFTON HISTORIC PRESERVATION COMMISSION ELECTRONIC MEETING Wednesday, January 6, 2021 6:00p.m. This meeting can be viewed on the Town of Bluffton’s Facebook page https://www.facebook.com/TownBlufftonSC/ I. CALL TO ORDER II. ROLL CALL III. NOTICE REGARDING ADJOURNMENT The Historic Preservation Commission will not hear new items after 9:30 p.m. unless authorized by a majority vote of the Commission Members present. Items which have not been heard before 9:30 p.m. may be continued to the next regular meeting or a special meeting date as determined by the Commission Members. IV. NOTICE REGARDING PUBLIC COMMENTS* Every member of the public who is recognized to speak shall address the Chairman and in speaking, avoid disrespect to Commission, Staff, or other members of the Meeting. State your name and address when speaking for the record. COMMENTS ARE LIMITED TO THREE (3) MINUTES. V. ADOPTION OF AGENDA VI. ADOPTION OF MINUTES – December 2, 2020 VII. ELECTION OF OFFICERS – Election for vice-chair and Historic Preservation Review Committee Member VIII. PUBLIC COMMENTS FOR ITEMS NOT ON THE AGENDA* IX. OLD BUSINESS X. NEW BUSINESS A. Certificate of Appropriateness: A request by Pearce Scott Architects, on behalf of the owners Gerard and Beth Romski, for approval of a Certificate of Appropriateness to allow the addition of an 85 SF golf cart bay and 600 SF second story addition to the Town of Bluffton Historic Preservation Commission Agenda January 6, 2021 Page 2 existing one-story 514 SF Carriage House located at 5806 Yaupon Road, Lot 20A in the Stock Farm Development, in the Old Town Bluffton Historic District and zoned Neighborhood General-HD. (COFA-10-20-014698) (Staff – Katie Peterson) B. Certificate of Appropriateness: A request by Pearce Scott Architects, on behalf of the owner Kate Eagen, for approval of a Certificate of Appropriateness to allow the construction of a 1.5- story single-family residential structure of approximately 2,117 SF and a 2-story Carriage House of approximately 1,172 SF located at 5718 Guilford Place, Lot 45 in the Stock Farm Development in the Old Town Bluffton Historic District, and zoned Neighborhood General-HD. (COFA-10-20-014673) (Staff – Katie Peterson) C. Certificate of Appropriateness: A request by Webb Construction, on behalf of the owner Ernie Suozzi, for approval of a Certificate of Appropriateness to allow the construction of a 1.5-story single- family residential structure of approximately 1,954 SF and a 1-story Carriage House of approximately 352 SF located at 20 Meriwether Court, Lot 3 in the Landen Oaks Development in the Old Town Bluffton Historic District, and zoned Neighborhood General-HD. (COFA-10-20-014694) (Staff – Katie Peterson) XI. DISCUSSION 1. Discussion regarding large scale commercial development in Old Town Bluffton Historic District (No Staff Report Attached). XII. ADJOURNMENT 2. NEXT MEETING DATE– Wednesday, February 3, 2021 3. * Public Comments may be submitted electronically via the Town’s website at (https://bit.ly/TOBPublicComment ) or by emailing your comments to the Growth Management Coordinator at dmclain@townofbluffton.com. Comments will be accepted up to 2 hours prior to the scheduled meeting start time. All comments will be read aloud for the record and will be provided to the Historic Preservation Committee. “FOIA Compliance – Public notification of this meeting has been published and posted in compliance with the Freedom of Information Act and the Town of Bluffton policies.” In accordance with the requirements of Title II of the Americans with Disabilities Act of 1990 ("ADA"), the Town of Bluffton will not discriminate against qualified individuals with disabilities on the basis of disability in its services, programs, or activities. EXECUTIVE SESSION - The public body may vote to go into executive session for any item identified for action on the agenda. Any person requiring further accommodation should contact the Town of Bluffton ADA Coordinator at 843.706.4500 or adacoordinator@townofbluffton.com as soon as possible but no later than 48 hours before the scheduled event. Town of Bluffton  Historic Preservation Commission Page 1 of 4 December 2, 2020 TOWN OF BLUFFTON HISTORIC PRESERVATION COMMISSION Electronic Meeting Wednesday, December 2, 2020, Minutes Present: Bruce Trimbur - Chair; Will Guenther – Vice Chair; Courtney McNeil; Michael Lovecchio; and, Jesse Solomon Absent: Elaine Gallagher Adams Staff: Katie Peterson, Senior Planner; Kevin Icard, Planning and Community Development Manager; Charlotte Moore, Principal Planner; and, Darby McLain, Growth Management Coordinator I. CALL TO ORDER Chairman Trimbur called the meeting to order at 6:04 p.m. II. ROLL CALL Commissioner Solomon was not present for the roll call but arrived at 6:08 p.m. Commissioner Gallagher Adams was not in attendance. III. NOTICE REGARDING ADJOURNMENT The Historic Preservation Commission will not hear new items after 9:30 P.M. unless authorized by a majority vote of the Commission Members present. Items which have not been heard before 9:30 P.M. may be continued to the next regular meeting or an additional meeting date as determined by the Commission members. IV. NOTICE REGARDING PUBLIC COMMENTS Every member of the public who is recognized to speak shall address the Chairman and in speaking, avoid disrespect to the Commission, Town Staff, and other members of the meeting. State your name and address when speaking for the record. UNLESS OTHERWISE AMENDED BY THE HISTORIC PRESERVATION COMMISSION, COMMENTS ARE LIMITED TO THREE (3) MINUTES. V. ADOPTION OF THE AGENDA Commissioner Guenther made a motion to adopt the agenda. Commissioner McNeil seconded the motion. All were in favor and the motion passed. Commissioner Solomon was not present. VI. ADOPTION OF MINUTES Town of Bluffton  Historic Preservation Commission Page 2 of 4 December 2, 2020 Commissioner McNeil made a motion to adopt the November 4, 2020 Minutes. Commissioner Guenther seconded the motion. All were in favor the motion passed. Commissioner Solomon was not present. VII. ADOPTION OF 2021 MEETING DATES Commissioner Guenther made a motion to adopt the 2021 meeting dates as presented by Staff during the meeting. Commissioner Lovecchio seconded the motion. All were in favor and the motion passed. VIII. PUBLIC COMMENTS FOR ITEMS NOT ON THE AGENDA There were no public comments. IX. OLD BUSINESS There was no old business. X. NEW BUSINESS A. Certificate of Appropriateness: A request by Christopher Epps of InCircle Architecture, on behalf of the owners Trudy J. Eaton Trust, for approval of a Certificate of Appropriateness to allow the addition of a 578 SF second story addition to the existing one-story 514 SF Carriage House located at 23 Pritchard Street, Lot 1 in the Tabby Roads Development, in the Old Town Bluffton Historic District and zoned Neighborhood General-HD. (COFA-09- 20-014597) (Staff – Katie Peterson) Peterson presented the information to the Commission, which is incorporated into these minutes. Chris Epps, Applicant, spoke about the project and explained the approach to the addition. Mr. Epps indicated that his client is in the process of getting approval from the Tabby Roads Habitat and Architectural Review Board. Commissioner Guenther stated that he liked the creativity of the project. There were no other comments from the Commission. Commissioner Guenther made a motion to approve the application with the following condition: 1. Per the Applications Manual, the Application must be signed by the Property Owner. Commissioner Solomon seconded the Motion. Commissioner McNeil made a motion to Amend the Primary Motion to include that the letter of approval from Tabby Roads ARB be submitted to The Town. Town of Bluffton  Historic Preservation Commission Page 3 of 4 December 2, 2020 2. Prior to approval, a copy of the letter of approval from the Tabby Roads ARB is required. Commissioner Solomon seconded the motion to amend the Primary Motion. All voted in favor to amend to the Primary Motion and the motion to amend passed. All voted in favor of Amended Primary Motion and the motion passed. B. Certificate of Appropriateness - HD: A request by Pearce Scott Architects, on behalf of the owners, Gerard and Beth Romski for approval of a Certificate of Appropriateness to allow the addition of 120 SF outdoor shower and a dog door on the exiting 2,849 SF single-family residence located at 5806 Yaupon Road, Lot 20A in the Stock Farm Development, in the Old Town Bluffton Historic District and zoned Neighborhood General- HD. (COFA-09-20- 014957) (Staff – Katie Peterson) Peterson presented the information to the Commission, which is incorporated into these minutes. Chairman Trimbur asked the Applicant, Sam Bielanin with Pearce Scott Architects, if she had anything to add. She did not. Commissioner Solomon asked about purpose of the roof configuration. Bielani replied that as the shower area was smaller than the gabled roof above, they chose a smaller shed roof rather than bring the full gabled roof out. She indicated that roof will be metal. Commissioner Guenther said the metal roof looks appropriate. Commissioner McNeil made a motion to approve as submitted. Commissioner Solomon seconded the motion. All were in favor and the motion passed. C. Certificate of Appropriateness - HD: A request by Dan Keefer for approval of a Certificate of Appropriateness to allow the addition of a 396 SF carport and storage area to the existing 577 SF Carriage House located at 5469 Mistletoe Loop, Lot 41 in the Stock Farm Development, in the Old Town Bluffton Historic District and zoned Neighborhood General-HD. (COFA-10- 20-014675)(Staff – Katie Peterson) Peterson presented the information to the Commission, which is incorporated into these minutes. Commissioner Solomon made a motion to approve the application as submitted by the Applicant as the HPC found that in this case, the use of the sliding barn doors on the courtyard side of the Carriage House was an appropriate substitute for the door operations found in Section 5.15.6.I. of Town of Bluffton  Historic Preservation Commission Page 4 of 4 December 2, 2020 the UDO. Commissioner McNeil seconded the motion. All were in favor and the motion passed. XI. DISCUSSION 1. Chairman Trimbur thanked Commissioner Guenther for his many years of service on the Historic Preservation Commission and the Historic Preservation Review Committee. Peterson also thanked Commissioner Guenther for everything he put into the HPC and said she hoped to continue to see him active in the Historic District. Commissioner Guenther spoke on his time as a Commissioner and thanked both staff and the other Commissioners for their work. 2. Discussion Regarding Building Size in Old Town Bluffton Historic District. Moore presented several topics to be discussed in the future. The highlights included:  Focus on Neighborhood Center Historic District  Mass and scale should fit into streetscape  Consider reducing the maximum building footprint in the NCE-HD district to 2,000 – 2,500 sq. ft and the overall square footage to 4,500 sq. ft  Is there too much commercial development? How do we mitigate impacts like traffic and parking?  Is it time to update the Old Town Master Plan (2006)?  What UDO Amendments would be needed to accomplish? The Commissioners had multiple questions and concerns that the information being presented had not been fully reviewed and felt that it was premature to make any changes to the UDO at this time. Staff stated that they would present their concerns to the UDO Administrator and would follow up with the Commissioners at their next meeting. XII. ADJOURNMENT Commissioner Guenther made a motion to adjourn the December 2, 2020 Historic Preservation Commission meeting. Commissioner McNeil seconded the motion, and all were in favor. The meeting was adjourned at 7:38 p.m. 5806 Yaupon Road, Lot 20A– Certificate of Appropriateness Historic Preservation Commission HISTORIC PRESERVATION COMMISSION STAFF REPORT Department of Growth Management MEETING DATE: January 6, 2021 PROJECT: 5806 Yaupon Road, Lot 20A– Carriage House Addition APPLICANT: Pearce Scott Architects PROJECT MANAGER: Katie Peterson, AICP, Senior Planner APPLICATION REQUEST: The Applicant, Pearce Scott Architects, on behalf of the owners, Gerard and Beth Romski, requests that the Historic Preservation Commission approve the following application: 1. COFA-10-20-014698. A Certificate of Appropriateness to allow the addition of an 85 SF golf cart bay and 600 SF second story addition to the existing one-story 514 SF Carriage House located at 5806 Yaupon Road, Lot 20A in the Stock Farm Development, in the Old Town Bluffton Historic District and zoned Neighborhood General-HD. INTRODUCTION: The Applicant is proposing the construction of an 85 SF golfcart bay and 600 SF second story addition the existing primary Carriage House located at 5806 Yaupon Road in the Old Town Bluffton Historic District. The single-family residence and Carriage House were originally reviewed and approved by the Historic Preservation Commission at the May 6, 2015 HPC meeting (COFA-03-15- 009157). The proposed addition would expand the existing 15 SF bump-out to create a golf cart bay on the first floor, remove the roof of the existing Carriage House, and add a second story directly on top. The materials would be a continuation of the existing structure, and the roof shape and pitch would remain the same. The bracketed shed roof over the garage doors, which was approved in 2015, but not constructed would be installed at this time. This project was presented to the Historic Preservation Review Committee for conceptual review at the October 16, 2020 meeting and comments were provided to the Applicant (See Attachment 5). HISTORIC PRESERVATION COMMISSION ACTIONS: As granted by the powers and duties set forth in Section 2.2.6.E.2, the Historic Preservation Commission has the authority to take the following actions with respect to this application: 1. Approve the application as submitted by the Applicant; 2. Approve the application with conditions; or January 6, 2021 Page 2 5806 Yaupon Road, Lot 20A – Certificate of Appropriateness Historic Preservation Commission 3. Deny the application as submitted by the applicant. It is important to note that the intent of Section 5.15 Old Town Bluffton Historic District of the Unified Development Ordinance (UDO), is that the Section be user friendly and informative to the residents and the members of HPC and is not intended to discourage creativity or force the replication of historic models. Rather, it is to set forth a framework in which the diversity that has always characterized Bluffton can continue to grow. The Section also defines guidelines for design and materials similar to that used on structures within the Old Town, and it is the charge of the HPC to assess the interpretation of these guidelines as they pertain to applications using the established review criteria. REVIEW CRITERIA & ANALYSIS: Town Staff and the Historic Preservation Commission are required to consider the criteria set forth in Section 3.18.3 of the UDO in assessing an application for a Certificate of Appropriateness – Historic District (HD). The applicable criteria are provided below followed by a Staff Finding(s) based upon review of the application submittals to date. 1. Section 3.18.3.B. Consistency with the principles set forth in the Old Town Master Plan. a. Finding. The application is consistent with the principles set forth in the Old Town Master Plan. The Old Town Master Plan states that, “The built environment, in particular the historic structures scattered throughout Old Town, should be protected and enhanced. While it is of great importance to save and restore historic structures, it is just as important to add to the built environment in a way that makes Old Town more complete.” The Applicant proposes an addition to an existing Carriage House structure within the Old Town Bluffton Historic District, a locally and nationally designated historic district. The addition, with the conditions met found in Item 2 of this Section, has been designed to be sympathetic to the architectural character of the neighboring historic structures, so its addition to the architectural diorama will both protect the integrity of the existing historic structures and enhance the neighborhood by adding architectural variety. b. Finding. The Old Town Master Plan initiatives also include the adoption of a form-based code that included architectural standards for structures located within the Old Town Bluffton Historic District. These standards are included in Article 5 of the Unified Development Ordinance. The addition proposed as part of this request will be in conformance with those standards if the conditions noted in Item 2 of this Section are met. c. Finding. The Old Town Master Plan initiatives also promote preservation and protection of the legacy of the Old Town Bluffton Historic District through additions to the built environment which make Old Town more complete. The proposed addition will continue to provide completeness to the neighborhood and overall district. January 6, 2021 Page 3 5806 Yaupon Road, Lot 20A – Certificate of Appropriateness Historic Preservation Commission 2. Section 3.18.3.C. The application must be in conformance with applicable provisions provided in Article 5, Design Standards. a. Finding. Town Staff finds that the proposed addition will be in conformance with the applicable provisions provided in Article 5. 3. Section 3.18.3.D. The nature and character of the surrounding area and consistency of the structure with the harmony of the surrounding neighborhood. Finding. Town Staff finds that nature and character of the addition to the existing structure is consistent and harmonious with that of the surrounding neighborhood. The mass and scale of the addition is appropriate for its location and the architectural detailing is sensitive to the neighboring properties. 4. Section 3.18.3.F. The historic, architectural, and aesthetic features of the structure including the extent to which its alteration or removal would be detrimental to the public interest. Finding. The Applicant seeks approval for the addition to a Carriage House on a single-family residential lot built in 2015 in the Old Town Bluffton Historic District. The proposed plans are sympathetic in design to the neighboring historic and non-historic resources; therefore, the addition, as proposed, will have no adverse effect on the public interest. 5. Section 3.18.3.H. The application must comply with applicable requirements in the Applications Manual. Finding. The Certificate of Appropriateness Application has been reviewed by Town Staff and has been determined to be complete. STAFF RECOMMENDATION: It is the charge of the HPC to assess and interpret the standards and guidelines set forth in the UDO as they pertain to applications using the review criteria established in the UDO and to take appropriate action as granted by the powers and duties set forth in Section 2.2.6.E.2. Town Staff finds the requirements of Section 3.18.3 of the Unified Development Ordinance have been met and recommends that the Historic Preservation Commission approve the application as submitted. ATTACHMENTS: 1. Location Map 2. Zoning Map 3. Applicant Narrative 4. Application and Plans 5. HPRC Comments 6. HOA Approval 5806 Yaupon Road, Lot 20A: Location Map 1 2 / 2 1 / 2 0 2 0 0 0 . 0 3 0 . 0 5 0 . 0 8 0 . 1 0 . 1 30 . 0 1 m i F ATTACHMENT 1 5806 Yaupon Road, Lot 20A: Zoning Map 1 2 / 2 1 / 2 0 2 0 0 0 . 0 3 0 . 0 5 0 . 0 8 0 . 1 0 . 1 30 . 0 1 m i F O v e r r id e 1 P a r c e l P r o p e r t y L in e s ATTACHMENT 2 TOWN OF BLUFFTON CERTIFICATE OF APPROPRIATENESS- OLD TOWN BLUFFTON HISTORIC DISTRICT (HD) APPLICATION Town of Bluffton Certificate of Appropriateness-Historic District Application Last Updated: 4/8/2014 Growth Management Customer Service Center 20 Bridge Street Bluffton, SC 29910 (843)706-4522 www.townofbluffton.sc.gov applicationfeedback@townofbluffton.com Applicant Property Owner Name: Name: Phone: Phone: Mailing Address: Mailing Address: E-mail: E-mail: Town Business License # (if applicable): Project Information (tax map info available at http://www.townofbluffton.us/gis/) Project Name: Conceptual: Final: Amendment: Project Location: Application for: New Construction Renovation/Rehabilitation/Addition Relocation or Demolition Zoning District: Acreage: Tax Map Number(s): Project Description: Minimum Requirements for Submittal 1. Full sized copies and digital files of the Site Plan(s). One (1) set for Conceptual, two (2) sets for Final 2. Full sized copies and digital files of the Architectural Plan(s). One (1) set for Conceptual, two (2) sets for Final 3. Project Narrative describing reason for application and compliance with the criteri a in Article 3 of the UDO. 5. All information required on the attached Application Checklist. 6. An Application Review Fee as determined by the Town of Bluffton Master Fee Schedule. Checks made payable to the Town of Bluffton. Note: A Pre-Application Meeting is required prior to Application submittal. Disclaimer: The Town of Bluffton assumes no legal or financial liability to the applicant or any third party whatsoever by approving the plans associated with this permit. I hereby acknowledge by my signature below that the foregoing application is complete and accurate and that I am the owner of the subject property. As applicable, I authorize the subject property to be posted and inspected. Property Owner Signature: Date: Applicant Signature: Date: For Office Use Application Number: Date Received: Received By: Date Approved: ATTACHMENT 3 TOWN OF BLUFFTON CERTIFICATE OF APPROPRIATENESS – HISTORIC DISTRICT PROJECT ANALYSIS Last Updated: 4/8/2014 In accordance with the Town of Bluffton Unified Development Ordinance (UDO), the following information shall be included as part of a Certificate of Appropriateness application submitted for review by the Historic Preservation Commission (HPC) and the Historic Preservation Review Committee . The use of this checklist by Town Staff or the Applicant shall not constitute a waiver of any requirement contained in the UDO. 1. DESIGN REVIEW PHASE CONCEPTUAL REVIEW FINAL REVIEW 2. SITE DATA Identification of Proposed Building Type (as defined in Article 5): Building Setbacks Front: Rear: Rt. Side: Lt. Side: 3. BUILDING DATA Building Description (Main House, Garage, Carriage House, etc.) Existing Square Footage Proposed Square Footage Main Structure Ancillary Ancillary 4. SITE COVERAGE Impervious Coverage Coverage (SF) Building Footprint(s) Impervious Drive, Walks & Paths Open/Covered Patios A.TOTAL IMPERVIOUS COVERAGE B.TOTAL SF OF LOT % COVERAGE OF LOT (A/B= %) 5. BUILDING MATERIALS Building Element Materials, Dimensions, and Operation Building Element Materials, Dimensions, and Operation Foundation Columns Walls Windows Roof Doors Chimney Shutters Trim Skirting/Underpinning Water table Cornice, Soffit, Frieze Corner board Gutters Railings Garage Doors Balusters Green/Recycled Materials Handrails ATTACHMENT 3 TOWN OF BLUFFTON CERTIFICATE OF APPROPRIATENESS – HISTORIC DISTRICT APPLICATION CHECKLIST Town of Bluffton Applications Manual 2 of 3 Last Updated: 4/8/2014 Note: Certificate of Appropriateness application information will vary depending on the activities proposed. At a minimum, the following items (signified by a grayed checkbox) are required, as applicable to the proposed project. Concept Final BACKGROUND INFORMATION. COMPLETED CEFTIFICATE OF APPROPRIATENESS-HD APPLICATION: A competed and signed application providing general project and contact information. PROPERTY OWNER CONSENT: If the applicant is not the property owner, a letter of agency from the property owner is required to authorize the applicant to act on behalf of the property owner. PROJECT NARRATIVE: A detailed narrative describing the existing site conditions and use, the proposed development intent with proposed uses and activities that will be conducted on the site. Include a description of the proposed building type and proposed building materials as permitted in Article 5. DEED COVENANTS/RESTRICTIONS: A copy of any existing deed covenants, conditions and restrictions, including any design or architectural standards that apply to the site. ADDITIONAL APPROVALS: A written statement from the Declarant of any deed covenants, conditions, or restrictions and/or the Review Body of any design or architectural standards that the current design has been reviewed for consistency with the established restrictions/design principles and approved. Concept Final SITE ASSESSMENT. LOCATION MAP: Indicating the location of the lot and/or building within the Old Town Bluffton Historic District with a vicinity map. PROPERTY SURVEY: Prepared and sealed by a Registered Land Surveyor indicating the following, but not limited to:  All property boundaries, acreage, location of property markers, name of county, municipality, project location, and parcel identification number(s);  Municipal limits or county lines, zoning, overlay or special district boundaries, if they traverse the tract, form a part of the boundary of the tract, or are contiguous to such boundary;  All easements of record, existing utilities, other legal encumbrances, public and private rights-of-way, recorded roadways, alleys, reservations, and railways;  Existing watercourses, drainage structures, ditches, one-hundred (100) year flood elevation, OCRM critical line, wetlands or riparian corridors top of bank locations, and protected lands on or adjacent to the property;  Location of existing buildings, structures, parking lots, impervious areas, public and private infrastructure, or other man-made objects located on the development property; and  North arrow, graphic scale, and legend identifying all symbology. SITE PLAN: Showing layout and design indicating, but not limited to:  All property survey information showing all building footprint(s) with finish floor elevations, setbacks and build-to lines, building location(s), building orientation(s);  Overall lot configuration depicting ingress/egress, circulation, driveways, parking areas, patios, decks, pools, hardscape, service yards and all other site amenities;  Pedestrian circulation elements and ensuring design shows ADA accessibility compliance. Location, layout, and number of vehicular and bicycle parking spaces bicycle parking, and ensuring design shows ADA accessibility compliance; and  Include detailed dimensions as necessary and appropriate to demonstrate compliance with all applicable standards and requirements. ATTACHMENT 3 TOWN OF BLUFFTON CERTIFICATE OF APPROPRIATENESS – HISTORIC DISTRICT APPLICATION CHECKLIST Town of Bluffton Applications Manual 3 of 3 Last Updated: 4/8/2014 SIGN AND RETURN THIS CHECKLIST WITH THE APPLICATION SUBMITTAL ALL SUBMITTALS MUST BE COLLATED AND FOLDED TO 8-1/2” X 11” By signature below I certify that I have reviewed and provided the submittal items listed above . Further, I understand that failure to provide a complete, quality application or erroneous information may result in the delay of processing my application(s). ______________________________________________________ _______________________ Signature of Property Owner or Authorized Agent Date ______________________________________________________ Printed Name PHOTOS: Comprehensive color photograph documentation of the property, all exterior facades, and the features impacted by the proposed work. If digital, images should be at a minimum of 300 dpi resolution. Concept Final ARCHITECTURAL INFORMATION. CONCEPTUAL ARCHITECTURAL SKETCHES : Sketch of plans, elevations, details, renderings, and/or additional product information to relay design intent. FLOOR/ROOF PLANS : Illustrate the roof and floor plan configurations. Include all proposed uses, walls, door & window locations, overall dimensions and square footage(s). ELEVATIONS: Provide scaled and dimensioned drawings to i llustrate the exterior appearance of all sides of the building(s). Describe all exterior materials and finishes and include all building height(s) and heights of appurtenance(s) as they relates to adjacent grade, first floor finished floor elevations, floor to ceil ing height for all stories, existing and finish grades for each elevation. ARCHITECTURAL DETAILS : Provide scaled and dimensioned drawings to show the configuration and operation of all doors, windows, shutters as well as the configuration and dimensional information for columns and porch posts, corner boards, water tables, cupolas and roof appurtenances, gutters and downspouts, awnings, marquees, balconi es, colonnades, arcades, stairs, porches, stoops and railings. MANUFACTURER’S CUT SHEET/SPECIFICATIONS : Include for all atypical building elements and materials not expressly permitted by Article 5 of the UDO with sizes and finishes noted. Concept Final LANDSCAPE INFORMATION. TREE REMOVAL PLAN: A site plan indicating location, species, and caliper of existing trees and trees to be removed. LANDSCAPE PLAN: Plan must include proposed plant materials including names, quantities, sizes and location, trees to be removed/preserved/relocated, areas of planting, water features, extent of lawns, and areas to be vegetated. Plant key and list to be shown on the lan dscape plan as well as existing and proposed canopy coverage calculations. Concept Final ADDITIONAL REQUIRED INFORMATION (Single-Family Residential Excluded). PRELIMINARY DEVELOPMENT PLAN APPLICATION: Submit a Preliminary Development Plan Application along with all required submittal items as depicted on the application checklist. ATTACHMENT 3 December 04, 2020 Lot 20A Stock Farm Narrative On behalf of the owner, we would like to propose a new golf cart addition and second floor to the existing Garage. All details and materials will match existing and follow the UDO requirements. The windows on the existing garage will be relocated on the new addition. The covered connector will remain and is not in this scope of work. Please find attached drawings and the main house existing photos in this submittal. Thank you for your consideration, Amanda Jackson Denmark Project Manager ATTACHMENT 3 ATTACHMENT 3 ATTACHMENT 3 ATTACHMENT 3 Existing ATTACHMENT 4 Existing ATTACHMENT 4 Existing ATTACHMENT 4 EXISTING GARAGE EXISTING MAIN HOUSE PROPOSED ADDITION 1/8" = 1'-0" SITE PLAN 1 CH001 SITE PLAN N © 2020 PEARCE SCOTT ARCHITECTS PEARCE SCOTT ARCHITECTS 6 STATE OF MIND ST SUITE 200 BLUFFTON, SC 29910 843.837.5700 RENOVATION FOR: GERARD & BETH ROMSKI LOT 20A, 5806 YAUPON ROAD STOCK FARM BLUFFTON, SC 29910 DESCRIPTION / REVISION LOGNO. INITIALDATE PROJECT NO. 2075 DATE 10.20.20 DRAWN BY SDB CHECKED BY AWB SHEET NO. DO NOT SCALE FROM DRAWINGSNOT FOR CONSTRUCTION 24X36 PAPER SIZE CONCEPTUAL HPC SUBMITTAL AJD10.20.20 FINAL HPC SUBMITTAL - CH AJD11.03.20 ATTACHMENT 4 32'-0" 6'-0" 5'-312" 6'-0" 30" REF. SLOPEDSLOPED SLOPEDSLOPED EXISTING CONNECTOR ROOF BELOW 7'-0" VANITY 11'-6" 5'-3"5'-3" 10'-0" 24" X 28" STACKED W/D D/W R&S LIVING SPACE 002 CLOSET 004 BEDROOM 003 BATH 005 22'-0" 4'-9" 6'-612" 5'-1112" 4'-9" EXISTING DH WINDOW 5'-9" 5'-9" EXISTING CA WINDOW 10'-0" 22'-0" 5'-0" 5'-0" 22'-0" 11'-0" 002A 005A 003A 004A B B A B 3'-612" 7'-512" 4'-812" 1 COUNTERTOP WITH BRACKETS FOR SEATING 1 CH301 1 CH301 2 CH201 1 CH201 3 CH201 4 CH201 1 CH401 CL 3'-11" DN 3 3 FLAT CEILING 5'-3"5'-3"5'-3" 10'-0" 22'-0" 11'-6" EXISTING CONNECTOR EXISTING GARAGE REMOVE EXISTING ROOF AND CEILING STRUCTURE AND PREP FOR NEW SECOND FLOOR ADDITION CART BAY 001 EXISTING DH WINDOW 10'-0" 5'-0" 5'-0" 5'-9" 5'-9" EXISTING CA WINDOWS EXISTING DOOR EXISTING DOOR EXISTING DOOR 001A 5'-0" 5'-0" 2 2 1 CH301 1 CH301 2 CH201 1 CH201 3 CH201 4 CH201 4'-6" 4'-6" UP 1 CH401 3 7'-0" 2'-6"11'-6"8'-0" SERVICE YARD 10X10 POST8X8 POST AREA CALCULATIONS CONDITIONED SPACE: SECOND FLOOR UNCONDITIONED SPACE: GARAGE OVERALL TOTAL 599 599 1,198 LEGEND R&S: ROD AND SHELF : CENTERLINE 1. 18 RISERS @ +/- 7 1/2", 17 TREADS @ 11" EA. 2. REMOVE EXISTING WINDOW AND INFILL WITH NEW WALL TO MATCH EXISTING 3. RELOCATED WINDOW PROJECT NOTES GENERAL NOTES A. ALL SECOND FLOOR INTERIOR WALLS TO BE 2X6 UNLESS OTHERWISE NOTED. B. ALL INTERIOR DOORS TO BE 6" OFF OF ADJACENT STUD WALL UNLESS OTHERWISE NOTED C. ALL FIRST FLOOR CEILING HEIGHTS TO BE 9'-6" UNLESS OTHERWISE NOTED D. ALL SECOND FLOOR CEILING HEIGHTS TO BE 8'-0" UNLESS 0THERWISE NOTED E. ALL WINDOWS AND DOORS MEASURED TO THE CENTERLINE F. ALL EXTERIOR WINDOW MULLS TO BE 4" UNLESS OTHERWISE NOTED NEW FRAMING EXISTING FRAMING - BEFORE COMMENCING WORK, THE CONTRACTOR SHALL FILE ALL REQUIRED CERTIFICATES OF INSURANCE WITH THE DEPARTMENT OF BUILDINGS, OBTAIN ALL REQUIRED PERMITS, AND PAY ALL FEES REQUIRED BY BEAUFORT COUNTY. - THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS IN THE FIELD PRIOR TO COMMENCING WORK, AND SHALL REPORT ANY DISCREPANCIES BETWEEN DRAWINGS AND FIELD CONDITIONS TO THE ARCHITECT. - THE CONTRACTOR IS NOT TO SCALE DRAWINGS OR DETAILS. ONLY WRITTEN DIMENSIONS ARE TO BE USED. - MINOR DETAILS NOT USUALLY SHOWN OR SPECIFIED, BUT NECESSARY FOR PROPER CONSTRUCTION OF ANY PART OF THE WORK SHALL BE INCLUDED AS IF THEY WERE INDICATED IN THE DRAWINGS. - THE CONTRACTOR SHALL COORDINATE ALL WORK PROCEDURES WITH REQUIREMENTS OF LOCAL AUTHORITIES. - THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OF ALL CONDITIONS AND MATERIALS WITHIN THE PROPOSED CONSTRUCTION AREA. THE CONTRACTOR SHALL DESIGN AND INSTALL ADEQUATE SHORING AND BRACING FOR ALL STRUCTURAL OR REMOVAL TASKS. THE CONTRACTOR SHALL HAVE SOLE RESPONSIBILITY FOR ANY DAMAGE OR INJURIES CAUSED BY OR DURING THE EXECUTION OF THE WORK. - EACH CONTRACTOR SHALL LAY OUT HIS OWN WORK, AND SHALL PROVIDE ALL DIMENSIONS REQUIRED FOR OTHER CONTRACTORS (PLUMBING, ELECTRICAL, MECH). - PLUMBING, MECHANICAL AND ELECTRICAL WORK SHALL BE PERFORMED BY PERSONS LICENSED IN THEIR TRADES, WHO SHALL ARRANGE FOR AND OBTAIN INSPECTIONS AND REQUIRED SIGN-OFFS. - EACH CONTRACTOR SHALL DO CUTTING, PATCHING, REPAIRING AS REQUIRED TO PERFORM ALL OF THE WORK INDICATED ON THE DRAWINGS, AND ALL OTHER WORK THAT MAY BE REQUIRED TO COMPLETE THE JOB IN EACH PRIME CONTRACT. - EACH CONTRACTOR SHALL COORDINATE HIS WORK WITH THAT OF THE OTHER CONTRACTORS AND SUPPLIERS. DEMO GENERAL NOTES DOORS 001A 002A 003A 004A 005A WINDOWS A B NOTE: ALL HEAD, JAMB AND SILL DETAILS TO MATCH EXISTING WINDOW/DOOR SCHEDULE 6'-0" X 8'-0" OVERHEAD DOOR, MATCH EXISTING 3'-0" X 6'-8" 4 LITE, 1 PANEL (2/3 LITE) 2'-10" X 6'-9" BARN DOOR (2'-8" X 6'-8" C.O.) 2'-4" X 6'-8" POCKET DOOR 2'-4" X 6'-8" INTERIOR DOOR 2'-8" X 3'-6" CASEMENT, MATCH EXISTING 2'-8" X 5'-0" CASEMENT, MATCH EXISING CL EXISTING CONNECTOR BELOW 6:12 SLOPE RIDGE RIDGE 1'-0" 2'-0" 1'-0" 2'-0" 6:12 SLOPE 6:12 SLOPE6:12 SLOPE 4:12 SLOPE 4" 2'-0" 1 CH301 1 CH301 2 CH201 1 CH201 3 CH201 4 CH201 2'-5" METAL ROOF MATCH EXISTING LINE OF SECOND FLOOR BELOW ROOF BRACKETS BELOW 10'-0" +/- 5'-3"11'-6"+/- 5'-3" 10'-0" EXISTING GARAGE FOUNDATION SLOPE TO DRAIN TOP OF SLAB 6" A. FIN. GRADE MATCH EXISTING +/- 3'-0" EXISTING 7'-0" +/- 3'-0" EXISTING 7'-0" 1 CH301 1 CH301 19'-6" +/- 2'-6" 3'-10" BITUMINOUS EXPANSION FILLER NOTE: TIE NEW SLAB IN TO EXISTING SLAB 11'-6"8'-0" TOP OF SLAB 4" A. FIN. GRADE LINE OF POST ABOVE 1. 2. FOUNDATION NOTES: ARCHITECTURAL FOUNDATION FOR EXTERIOR DIMENSIONS & LEVEL CHANGES ONLY. REFER TO STRUCTURAL FOR ALL OTHER INFORMATION. CONTACT ARCHITECT IF MATERIALS CHANGE, AS THIS WILL AFFECT FINISHED FLOOR TO FINISHED FLOOR LEVEL CHANGES. REFER TO STRUCTURAL FOUNDATION PLAN FOR CONTROL JOINT LOCATIONS AND FOOTING SIZES AND DETAILS. 3. CONTRACTOR TO COORDINATE ALL FIRST FLOOR PLUMBING PRIOR TO SLAB POUR. 4. 5. ALL HARDSCAPE / PAVING, PADS, FILL & GRADING TO BE COORD. BY CONTRACTOR & LANDSCAPE ARCHITECT 1/4" = 1'-0" SECOND FLOOR PLAN 2 CH101 C.H. PLANS 1/4" = 1'-0" FIRST FLOOR PLAN 1 1/4" = 1'-0" ROOF PLAN 4 1/4" = 1'-0" FOUNDATION PLAN 3 © 2020 PEARCE SCOTT ARCHITECTS PEARCE SCOTT ARCHITECTS 6 STATE OF MIND ST SUITE 200 BLUFFTON, SC 29910 843.837.5700 RENOVATION FOR: GERARD & BETH ROMSKI LOT 20A, 5806 YAUPON ROAD STOCK FARM BLUFFTON, SC 29910 DESCRIPTION / REVISION LOGNO. INITIALDATE PROJECT NO. 2075 DATE 10.20.20 DRAWN BY SDB CHECKED BY AWB SHEET NO. DO NOT SCALE FROM DRAWINGSNOT FOR CONSTRUCTION 24X36 PAPER SIZE CONCEPTUAL HPC SUBMITTAL AJD10.20.20 FINAL HPC SUBMITTAL - CH AJD11.03.20 ATTACHMENT 4 412 HORIZONTAL LAP SIDING TO MATCH EXISTING SHAKE SIDING TO MATCH EXISTING 12 6 EXISTING CONNECTOR 6" GRADE T.O. SLAB @ GARAGE T.O. SUBFLOOR T.O. PLATE T.O. EXISTING DOOR 8'-0" 10'-111 4" 8'-11 4" 6'-83 4" T.O. WINDOW B 6" GRADE T.O. SLAB @ GARAGE T.O. SUBFLOOR T.O. DOOR 8'-0" 10'-111 4" 6'-83 4" T.O. WINDOW B B A 1 CH301 HORIZONTAL LAP SIDING TO MATCH EXISTING METAL ROOF TO MATCH EXISTING CLOSED SOFFIT TO MATCH EXISTING WOOD HANDRAILS & STEPS 6" GRADE T.O. SLAB @ GARAGE T.O. SUBFLOOR T.O. DOOR 8'-0" 10'-111 4" 6'-83 4" T.O. WINDOW EXISTING WINDOW EXISTING WINDOW 5'-0" TO BE REUSED/ RELOCATED TO BE REUSED/ RELOCATED 1 CH301 SERVICE YARD UNDER STAIR MATCH EXISTING 6" GRADE T.O. SLAB @ GARAGE T.O. SUBFLOOR T.O. PLATE T.O. WINDOW 8'-0" 10'-111 4" 8'-11 4" 6'-83 4" T.O. WINDOW 12 6 4 12 EXISTING WINDOW EXISTING WINDOW EXISTING WINDOW 1 CH401 9'-1012" B.O. BEAM 3 CH301 TO BE REUSED/ RELOCATED TO BE REUSED/ RELOCATED 1/4" = 1'-0" FRONT ELEVATION 1 1/4" = 1'-0" REAR ELEVATION 2 CH201 C.H. ELEVATIONS © 2020 PEARCE SCOTT ARCHITECTS PEARCE SCOTT ARCHITECTS 6 STATE OF MIND ST SUITE 200 BLUFFTON, SC 29910 843.837.5700 RENOVATION FOR: GERARD & BETH ROMSKI LOT 20A, 5806 YAUPON ROAD STOCK FARM BLUFFTON, SC 29910 DESCRIPTION / REVISION LOGNO. INITIALDATE PROJECT NO. 2075 DATE 10.20.20 DRAWN BY SDB CHECKED BY AWB SHEET NO. DO NOT SCALE FROM DRAWINGSNOT FOR CONSTRUCTION 24X36 PAPER SIZE CONCEPTUAL HPC SUBMITTAL AJD10.20.20 FINAL HPC SUBMITTAL - CH AJD11.03.20 1/4" = 1'-0" RIGHT ELEVATION 4 1/4" = 1'-0" LEFT ELEVATION 3 ATTACHMENT 4 8'-0" 13'-31 4"9'-6" EXISTING GARAGE CART BAY BEYOND LIVING SPACE 002 CLOSET 004 VAULTED SPACE BEYOND 12 6 TYPE 'X' GYP. 2X8 CEILING FRAMING 2X8 ROOF FRAMING WOOD CASING, MATCH EXISTING 3 1/2" 5 1/2" 1" SQUARE WOOD PICKETS 4X4 P.T. NEWEL POST W/ CAP 5/4 X TREADS & RISERS 1" SQUARE WOOD PICKETS P.T. 1x4 P.T. 2X4 TOP RAIL, DOUBLE SLOPED TOP P.T. 1x BOTTOM RAIL 2" 5" 1" 2 1/2"2'-3 1/2" P.T. 2X4 TOP RAIL, DOUBLE SLOPED TOP 3 3/4" 3'-0" +/- 6" 1" 10" 6" 3'-0" 4 12 2'-6" 5 1/2" 2'-2 1/2" 5 1/2"6" 4" 1'-8" 3" 4" 2" BRACKET ELEVATION HURRICANE CLIP @ EA. RAFTER 2X8 RAFTERS @ 16" O.C., SEE STRUCTURAL METAL ROOF MATCH EXISTING EXTERIOR ROOF SHEATHING 6X6 BEAM 3 4" DIA. LAG SCREWS (MIN. 4" PEN. IN TO BLOCKING), PLUG WITH LIKE WOOD (2) 2X BLOCKING @ EA. BRACKET P.T. 2X6 VERTICAL WALL SUPPORT @ EA. BRACKET P.T. 6X6 BRACKET 5 8" DIA. GALV. THRU BOLT (COUNTERSINK) 1 2" DIA. LAG SCREW (MIN. 2.5" PEN. INTO 6X6), PLUG WITH LIKE WOOD P.T. 6X6 1 2" DIA. LAG SCREW (MIN. 2.5" PEN.) (2) 2X BLOCKING @ EA. BRACKET 2'-0" 45° 5 1/2" 5 1/2" 3 1/2" THRU WALL FLASHING 3'-2" COUNTER FLASHING 2X BLOCKING AS REQUIRED 2X6 LEDGER BOARD 1X4 2X FRIEZE SIDING - SEE ELEVATION 2 1/2" THRU WALL FLASHING METAL DRIP EDGE 2X8 1X4 TRIM 1X8 TRIM INTERIOR FLOOR FINISH P.T. SHIM DOOR, SEE SCHEDULE 2X FLOOR FRAMING, SEE STRUCTURAL P.T. WOOD SILL METAL PAN FLASHING W/ END DAMS STAIR FRAMING, SEE STRUCTURAL WOOD DECKING SLOPE TO DRAIN 3" 3" 13 4" 1 2" CH301 BUILDING SECTION & DETAILS 1" = 1'-0" WINDOW TRIM 2 1/4" = 1'-0" BUILDING SECTION 1 © 2020 PEARCE SCOTT ARCHITECTS PEARCE SCOTT ARCHITECTS 6 STATE OF MIND ST SUITE 200 BLUFFTON, SC 29910 843.837.5700 RENOVATION FOR: GERARD & BETH ROMSKI LOT 20A, 5806 YAUPON ROAD STOCK FARM BLUFFTON, SC 29910 DESCRIPTION / REVISION LOGNO. INITIALDATE PROJECT NO. 2075 DATE 10.20.20 DRAWN BY SDB CHECKED BY AWB SHEET NO. DO NOT SCALE FROM DRAWINGSNOT FOR CONSTRUCTION 24X36 PAPER SIZE CONCEPTUAL HPC SUBMITTAL AJD10.20.20 FINAL HPC SUBMITTAL - CH AJD11.03.20 1" = 1'-0" RAILING DETAIL 4 1" = 1'-0" BRACKET DETAIL 33" = 1'-0" DOOR SILL, TYP. 5 ATTACHMENT 4 3 CH401 6" GRADE T.O. SLAB @ GARAGE 9'-6" T.O. SUBFLOOR 10'-11 1/4" 8'-1 1/4" 16" FLOOR SYSTEM TYPE 'X' GYP. BOARD T.O. PLATE 6 12 2 CH401 2X6 STUD WALL @ 16" O.C. W/ THERMAL INSULATION MOISTURE BARRIER OVER 1/2" EXTERIOR SHEATHING HURRICANE CLIP @ EA. RAFTER 2X RAFTERS @ 16" O.C., SEE STRUCTURAL METAL DRIP EDGE 2X8 1X4 HARDIE SOFFIT SPRAY FOAM INSULATION AT ALL ROOFS, TYP. 1X4 TRIM 1X8 TRIM SIDING, MATCH EXISTING STANDING SEAM METAL ROOF MATCH EXISTING NOTE: PER CODE, RAFTER NOTCH CANNOT EXCEED 25% DEPTH OF RAFTER ICE & WATER SHIELD OVER ROOF SHEATHING (2) 2X6 TOP PLATE INTERIOR WALL FINISH 6 12 2'-0" 1 2" P.T. 2X10 HARDIE TRIM BOTTOM OF TRIM TO ACT AS WINDOW HEAD TRIM P.T. 2X2 (ACTUAL) HARDIE TRIM MOISTURE BARRIER OVER 1/2" EXTERIOR SHEATHING ANCHOR BOLT PER STRUCTURAL BLOCKING AS REQ'D FOR TRIM INTERIOR WALL FINISH P.T. STARTER STRIP FOUNDATION, SEE STRUCTURAL GRADE - SLOPE TO DRAIN P.T. 2X6 BASE PLATE +/- 6" CONTINUOUS METAL FLASHING, LAP MOISTURE BARRIER OVER FLASHING EXTEND UP WALL MIN. 16" SIDING, MATCH EXISTING 2X6 STUD WALL @ 16" O.C. 1 1/2" = 1'-0" FOUNDATION DETAIL 3 1" = 1'-0" WALL SECTION 1 1 1/2" = 1'-0" EAVE DETAIL 2 CH401 WALL SECTION & DETAILS © 2020 PEARCE SCOTT ARCHITECTS PEARCE SCOTT ARCHITECTS 6 STATE OF MIND ST SUITE 200 BLUFFTON, SC 29910 843.837.5700 RENOVATION FOR: GERARD & BETH ROMSKI LOT 20A, 5806 YAUPON ROAD STOCK FARM BLUFFTON, SC 29910 DESCRIPTION / REVISION LOGNO. INITIALDATE PROJECT NO. 2075 DATE 10.20.20 DRAWN BY SDB CHECKED BY AWB SHEET NO. DO NOT SCALE FROM DRAWINGSNOT FOR CONSTRUCTION 24X36 PAPER SIZE CONCEPTUAL HPC SUBMITTAL AJD10.20.20 FINAL HPC SUBMITTAL - CH AJD11.03.20 ATTACHMENT 4 DUPLEX OUTLET GROUND FAULT CIRCUIT INTERUPTER WEATHER-PROOF OUTLET SWITCHED OUTLET 220 V. OUTLET FLOOR OUTLET CABLE T.V. JACK TELEPHONE JACK SURFACE MOUNTED CEILING FIXTURE CHANDELIER WALL FIXTURE EXHAUST FAN SWITCH THREE-WAY SWITCH FOUR-WAY SWITCH FAN SWITCH CEILING FAN RECESSED FIXTURE GARBAGE DISPOSAL PENDANT DIMMER SWITCH ELECTRICAL LEGEND DATA WALL WASHER GENERAL ELECTRICAL PLAN NOTES: 1. COORDINATE W/ OWNER ELECTRICAL ROUGH-IN LOCATIONS PRIOR TO START OF ELECTRICAL WORK. 2. INSTALL SMOKE DETECTORS IN ACCORDANCE WITH SECTION R313 (SMOKE ALARMS) OF THE INTERNATIONAL RESIDENTIAL CODE. 3. COORDINATE THERMOSTAT LOCATIONS W/ OWNER AND PER FINAL HVAC RETURN GRILLE LOCATIONS. 4. COORDINATE LANDSCAPE LIGHTS AND GAS LAMP POST LOCATIONS W/ LANDSCAPE ARCHITECT. 5. COORDINATE METER SIZE WITH CONTRACTOR WATER PROOF RECESSED FIXTURE SLOPED RECESSED FIXTURE UNDER COUNTER LIGHT GAS LIGHT SMOKE DETECTOR FLOURESCENT LIGHT GARAGE DOOR OPENER J JUNCTION BOX METER - SIZE TBD BY CONTRACTOR KING TO LIGHT & SWITCH BELOW LIVING SPACE 002 CLOSET 004 BEDROOM 003 BATH 005 TIE INTO EXISTING GARAGE ELECTRICAL TO LIGHT & SWITCH ABOVE TIE INTO EXISTING GARAGE ELECTRICAL CART BAY 001 EXISTING GARAGE ELECTRICAL TO REMAIN ELECTRICAL PLANS 1/4" = 1'-0" FIRST FLOOR ELECTRICAL PLAN 1 CH-E101 © 2020 PEARCE SCOTT ARCHITECTS PEARCE SCOTT ARCHITECTS 6 STATE OF MIND ST SUITE 200 BLUFFTON, SC 29910 843.837.5700 RENOVATION FOR: GERARD & BETH ROMSKI LOT 20A, 5806 YAUPON ROAD STOCK FARM BLUFFTON, SC 29910 DESCRIPTION / REVISION LOGNO. INITIALDATE PROJECT NO. 2075 DATE 10.20.20 DRAWN BY SDB CHECKED BY AWB SHEET NO. DO NOT SCALE FROM DRAWINGSNOT FOR CONSTRUCTION 24X36 PAPER SIZE CONCEPTUAL HPC SUBMITTAL AJD10.20.20 FINAL HPC SUBMITTAL - CH AJD11.03.20 1/4" = 1'-0" SECOND FLOOR ELECTRICAL PLAN 2 ATTACHMENT 4 PLAN REVIEW COMMENTS FOR COFA-10-20-014698 Town of Bluffton Department of Growth Management 20 Bridge Street P.O. Box 386 Bluffton, South Carolina 29910 Telephone 843-706-4522 OLD TOWN Plan Type: Apply Date: Plan Status: Plan Address: 5806 Yaupon Rd Road BLUFFTON, SC 29910 Historic District Active 10/22/2020 Plan PIN #:Case Manager: R610 039 000 1626 0000Katie Peterson Plan Description: A request by Pearce Scott Architects, on behalf of owners, Gerard and Beth Romski, for review of a Certificate of Appropriateness Application to allow for the addition of a golf cart bay and second floor of approximately 599 SF to the existing Carriage House of approximately 514 SF located at 5806 Yaupon Road, identified as Lot 20A in the Stock Farm Development, in the Old Town Bluffton Historic District and zoned Neighborhood General – HD. STATUS 10-27-2020: The application is currently being reviewed by Staff for conformance with the Unified Development Ordinance (UDO), Traditional Construction Patterns, and any development plans associated with the parcel and is scheduled for review by the HPRC at the November 16, 2020 meeting. Staff Review (HD) Submission #: 1 Recieved: 10/29/2020 Completed: 11/13/2020 Reviewing Dept. Complete Date StatusReviewer Approved with Conditions11/13/2020Building Safety Review Richard Spruce Comments: 1. Comments may be provided at Building Permit. Approved with Conditions11/13/2020Growth Management Dept Review (HD) Katie Peterson Comments: 1. For the Final submittal, a letter of approval from the Stock Farm HARC is required. (Applications Manual) Approved with Conditions11/13/2020HPRC Review Katie Peterson Comments: 1. For the final application provide architectural details of the railings and balusters, window detail, corner board trim, a typical wall section, and a wall section through the eave depicting the material configuration and dimensions and photos of the primary structure for context. (Applications Manual) Approved11/10/2020Beaufort Jasper Water and Sewer Review James Clardy Comments: 1. No Comment. Approved11/10/2020Transportation Department Review - HD William Howard Comments: 1. No Comment. Approved11/12/2020Watershed Management Review William Baugher Approved11/03/2020Addressing Review Nick Walton 11/13/2020 Page 1 of 2 ATTACHMENT 5 Plan Review Case Notes: 11/13/2020 Page 2 of 2 ATTACHMENT 5 STOCK FARM DEVELOPMENT BOX 2570 BLUFFTON, SC 29910 15 December 2020 To: Katie Peterson, Town of Bluffton Subject: HPC Review of Stock Farm Applications Katie—It is understood that the HPC, in January, will review plans from two applicants and Stock Farm property owners: -----Romski-5806 Yaupon Road (Lot 20A)—Carriage House Additions -----Eagen-5718 Guilford Place (Lot 45)—Personal Residence Stock Farm has reviewed the plans and found these to meet the community requirements. It is recommended that these plans be granted a Certificate of Appropriateness. Emmett McCracken Manager ATTACHMENT 6 5718 Guilford Place, Lot 45 – Certificate of Appropriateness Historic Preservation Commission HISTORIC PRESERVATION COMMISSION STAFF REPORT Department of Growth Management MEETING DATE: January 6, 2021 PROJECT: Lot 45, 5718 Guilford Place – New Construction: Single-Family Residential APPLICANT: Pearce Scott Architects PROJECT MANAGER: Katie Peterson, AICP, Senior Planner APPLICATION REQUEST: The Applicant, Pearce Scott Architects, on behalf of Kate Eagen, requests that the Historic Preservation Commission approve the following application: 1. COFA-10-20-014673. A Certificate of Appropriateness to allow the construction of a 1.5-story single-family residential structure of approximately 2,117 SF and a 2-story Carriage House of approximately 1,172 SF located at 5718 Guilford Place, Lot 45 in the Stock Farm Development in the Old Town Bluffton Historic District, and zoned Neighborhood General-HD. INTRODUCTION: The Applicant is proposing the construction of a detached single- family residence located in the Old Town Bluffton Historic District. The proposed building, of approximately 2,117 SF, has similar attributes of the Village House, but is not 2 stories in height, so it is reviewed as an Additional Building Type in accordance with the allowable building types for the Neighborhood General-HD zoning district. In addition to the primary structure, the Applicant is proposing a Carriage House structure of approximately 1,172 SF, which meets the design standards for a Carriage House Building Type. While this lot is located within the Stock Farm Development, it was added to the development through a Development Plan Amendment in 2018 (DPA-12-18-012661), which specified that the lot must meet the setbacks found in the Unified Development Ordinance, which is different than most lots within this development. The main house structure is under a two-story forward-facing gable with a one- story gabled projection to the rear. It features a front porch under a shed roof which wraps around the left side and extends halfway back. The proposed materials include combination of horizontal lap siding and vertical board and batten, a 5V metal roof and the piers and chimneys are done in Tabby stucco. The Carriage House, which features similar materials as the primary structure, is connected by a breezeway to the primary structure. It is a two-story structure under a gable roof with a second garage bay under a one-story shed roof. January 6, 2021 Page 2 5718 Guilford Place, Lot 45 – Certificate of Appropriateness Historic Preservation Commission This project was presented to the Historic Preservation Review Committee for conceptual review at the November 2, 2020 meeting and comments were provided to the Applicant (See attachment 6). HISTORIC PRESERVATION COMMISSION ACTIONS: As granted by the powers and duties set forth in Section 2.2.6.E.2, the Historic Preservation Commission has the authority to take the following actions with respect to this application: 1. Approve the application as submitted by the Applicant; 2. Approve the application with conditions; or 3. Deny the application as submitted by the Applicant. It is important to note that the intent of Section 5.15 Old Town Bluffton Historic District of the Unified Development Ordinance (UDO) is that the Section be user friendly and informative to the residents and the members of HPC and is not intended to discourage creativity or force the replication of historic models. Rather, it is to set forth a framework in which the diversity that has always characterized Bluffton can continue to grow. The Section also defines guidelines for design and materials similar to that used on structures within the Old Town, and it is the charge of the HPC to assess the interpretation of these guidelines as they pertain to applications using the established review criteria. REVIEW CRITERIA & ANALYSIS: Town Staff and the Historic Preservation Commission are required to consider the criteria set forth in Section 3.18.3 of the UDO in assessing an application for a Certificate of Appropriateness – Historic District (HD). The applicable criteria are provided below followed by a Staff Finding(s) based upon review of the application submittals to date. 1. Section 3.18.3.B. Consistency with the principles set forth in the Old Town Master Plan. a. Finding. The application is consistent with the principles set forth in the Old Town Master Plan. The Old Town Master Plan states that, “The built environment, in particular the historic structures scattered throughout Old Town, should be protected and enhanced. While it is of great importance to save and restore historic structures, it is just as important to add to the built environment in a way that makes Old Town more complete.” The Applicant proposes to construct a new single-family residence and Carriage House within the Old Town Bluffton Historic District, a locally and nationally designated historic district. The buildings have been designed to be sympathetic to the architectural character of the neighboring historic structures, so their addition to the architectural diorama will both protect the integrity of the existing historic structures and enhance the neighborhood by adding architectural variety. b. Finding. The Old Town Master Plan initiatives also include the adoption of a form-based code that included architectural standards for structures located within the Old Town Bluffton Historic District. These standards are included in Article 5 of the UDO. The new construction proposed as January 6, 2021 Page 3 5718 Guilford Place, Lot 45 – Certificate of Appropriateness Historic Preservation Commission part of this request will be in conformance with those standards if the conditions noted in item 2 of this Section are met. c. Finding. The Old Town Master Plan initiatives also promote preservation and protection of the legacy of the Old Town Bluffton Historic District through additions to the built environment which make Old Town more complete. The addition of the proposed residential structure and Carriage House add to the district as well as help provide completeness to the neighborhood and overall district. 2. Section 3.18.3.C. The application must be in conformance with applicable provisions provided in Article 5, Design Standards. a. Finding. Town Staff finds that the design of the primary structure falls within the category of Additional Building Type as allowed in the Neighborhood General Historic District per Section 5.15.5.C. Additional Building Types are permissible. As has been past practice, the Town Staff requests the Historic Preservation Commission review and make a final recommendation regarding the appropriateness of the Additional Building Type. b. Finding. Town Staff finds that if the conditions noted below are met, the proposed addition will be in conformance with applicable provisions provided in Article 5: 1) Section 5.15.6.H. Columns, Arches, Piers, Railings, Balustrades. The UDO states that columns and porch posts shall be spaced no farther apart than they are tall. The proposed columns on the front porch closest to the left side are spaced approximately 10’ 8” apart on center and are 10’ 0” tall, and the furthest back bay on the left elevation is proposed at 10’ 6” on center and are 10’ 0” tall. The columns must be reconfigured to meet the dimensional standards found in the UDO. 2) Section 5.15.6.I. Windows and Doors. Doors must be wood, metal, or metal-clad. The door schedule notes fir- or similar, however, Note 4 on the door schedule notes that door style shall be specified by owner. Note 4 must be updated and exterior doors selected by owner prior to approval. 3. Section 3.18.3.D. Consistency with the nature and character of the surrounding area and consistency of the structure with the scale, form and building proportions of the surrounding neighborhood. Finding. Town Staff finds the nature and character of the new construction to be consistent and harmonious with that of the surrounding neighborhood. The mass and scale of the structure is appropriate for its location and the architectural detailing is sensitive to the neighboring properties. January 6, 2021 Page 4 5718 Guilford Place, Lot 45 – Certificate of Appropriateness Historic Preservation Commission 4. Section 3.18.3.F. The historic, architectural, and aesthetic features of the structure including the extent to which its alteration or removal would be detrimental to the public interest. Finding. The Applicant seeks approval for the construction of new structures in the Old Town Bluffton Historic District. The proposed plans are sympathetic in design to the neighboring historic and non-historic resources; therefore, the structure, as proposed, will have no adverse effect on the public interest. 5. Section 3.18.3.H. The application must comply with applicable requirements in the Applications Manual. Finding. The application has been reviewed by Town Staff and has been determined to be complete. However, it appears at there are a number of trees over 14” in diameter that will require removal for the placement of the structure. A Town of Bluffton tree removal permit must be submitted, reviewed and approved prior to any site clearing. A 6” Magnolia has been marked on the site plan to stay but is shown to be removed on the landscape plan. Clarify if the magnolia should be removed or stay. Additionally, a grading plan, showing all removal and fill for the site must be provided prior to approval per Section 3.2.2.E. of the UDO, as not enough information was provided at time of submittal. Please note that care shall be given to root systems of trees to remain on the site. STAFF RECOMMENDATION: It is the charge of the HPC to assess and interpret the standards and guidelines set forth in the UDO as they pertain to applications using the review criteria established in the UDO and to take appropriate action as granted by the powers and duties set forth in Section 2.2.6.E.2. Town Staff finds that with the conditions noted below, the requirements of Section 3.18.3 of the Unified Development Ordinance have been met and recommends that the Historic Preservation Commission approve the application with the following conditions: 1. Per Section 5.3.3.A.1. of the UDO, a Town of Bluffton tree removal permit is required for the removal of any trees over 14” in DBH. 2. Provide clarification on the 6” magnolia shown to stay on the site plan but removed on the landscape plan. 3. Per Section 5.15.6.H. of the UDO, columns must be reconfigured to be spaced no farther apart than they are tall at the front left corner and the left side in the last bay. 4. Per Section 5.15.6.I. of the UDO, the door style must be specified by owner prior to approval and Note 4 on the door schedule updated. 5. Per Section 3.2.2.E. of the UDO, a Grading Plan for the site is required for review as not enough information was provided at time of submittal. ATTACHMENTS: 1. Location Map 2. Zoning Map 3. Application &Applicant Narrative January 6, 2021 Page 5 5718 Guilford Place, Lot 45 – Certificate of Appropriateness Historic Preservation Commission 4. Site Plan & Elevations 5. Landscape Plan 6. HPRC Report 7. POA Approval Letter 5718 Guilford Place, Lot 45: Location Map 1 2 / 2 1 / 2 0 2 0 0 0 . 0 3 0 . 0 5 0 . 0 8 0 . 1 0 . 1 30 . 0 1 m i F ATTACHMENT 1 5718 Guilford Place, Lot 45: Zoning Map 1 2 / 2 1 / 2 0 2 0 0 0 . 0 3 0 . 0 5 0 . 0 8 0 . 1 0 . 1 30 . 0 1 m i F O v e r r id e 1 P a r c e l P r o p e r t y L in e s ATTACHMENT 2 TOWN OF BLUFFTON CERTIFICATE OF APPROPRIATENESS- OLD TOWN BLUFFTON HISTORIC DISTRICT (HD) APPLICATION Town of Bluffton Certificate of Appropriateness-Historic District Application Last Updated: 4/8/2014 Growth Management Customer Service Center 20 Bridge Street Bluffton, SC 29910 (843)706-4522 www.townofbluffton.sc.gov applicationfeedback@townofbluffton.com Applicant Property Owner Name: Name: Phone: Phone: Mailing Address: Mailing Address: E-mail: E-mail: Town Business License # (if applicable): Project Information (tax map info available at http://www.townofbluffton.us/gis/) Project Name: Conceptual: Final: Amendment: Project Location: Application for: New Construction Renovation/Rehabilitation/Addition Relocation or Demolition Zoning District: Acreage: Tax Map Number(s): Project Description: Minimum Requirements for Submittal 1. Full sized copies and digital files of the Site Plan(s). One (1) set for Conceptual, two (2) sets for Final 2. Full sized copies and digital files of the Architectural Plan(s). One (1) set for Conceptual, two (2) sets for Final 3. Project Narrative describing reason for application and compliance with the criteri a in Article 3 of the UDO. 5. All information required on the attached Application Checklist. 6. An Application Review Fee as determined by the Town of Bluffton Master Fee Schedule. Checks made payable to the Town of Bluffton. Note: A Pre-Application Meeting is required prior to Application submittal. Disclaimer: The Town of Bluffton assumes no legal or financial liability to the applicant or any third party whatsoever by approving the plans associated with this permit. I hereby acknowledge by my signature below that the foregoing application is complete and accurate and that I am the owner of the subject property. As applicable, I authorize the subject property to be posted and inspected. Property Owner Signature: Date: Applicant Signature: Date: For Office Use Application Number: Date Received: Received By: Date Approved: ATTACHMENT 3 TOWN OF BLUFFTON CERTIFICATE OF APPROPRIATENESS – HISTORIC DISTRICT PROJECT ANALYSIS Last Updated: 4/8/2014 In accordance with the Town of Bluffton Unified Development Ordinance (UDO), the following information shall be included as part of a Certificate of Appropriateness application submitted for review by the Historic Preservation Commission (HPC) and the Historic Preservation Review Committee . The use of this checklist by Town Staff or the Applicant shall not constitute a waiver of any requirement contained in the UDO. 1. DESIGN REVIEW PHASE CONCEPTUAL REVIEW FINAL REVIEW 2. SITE DATA Identification of Proposed Building Type (as defined in Article 5): Building Setbacks Front: Rear: Rt. Side: Lt. Side: 3. BUILDING DATA Building Description (Main House, Garage, Carriage House, etc.) Existing Square Footage Proposed Square Footage Main Structure Ancillary Ancillary 4. SITE COVERAGE Impervious Coverage Coverage (SF) Building Footprint(s) Impervious Drive, Walks & Paths Open/Covered Patios A.TOTAL IMPERVIOUS COVERAGE B.TOTAL SF OF LOT % COVERAGE OF LOT (A/B= %) 5. BUILDING MATERIALS Building Element Materials, Dimensions, and Operation Building Element Materials, Dimensions, and Operation Foundation Columns Walls Windows Roof Doors Chimney Shutters Trim Skirting/Underpinning Water table Cornice, Soffit, Frieze Corner board Gutters Railings Garage Doors Balusters Green/Recycled Materials Handrails ATTACHMENT 3 December 08, 2020 Lot 45 Stock Farm Narrative On behalf of the owner, we would like to propose a Single Family Residence with a Carriage House. The house will be located at the end of the Guilford Place Cul-de-sac. The house is 2,117 heated square feet and the carriage house is 448 heated sf. All details and materials will follow the UDO requirements. The finished floor will be 36” above finished grade and the porches will be 30” above finished grade. The landscape plan will show the grades. We realize the column spacing on the wrapped corner is not in complete compliance with the UDO, but we ask for a deviation as it is difficult to have the exact dimensions when creating a corner element. The dimension from center of column to center of column is 10’ 3” where as the height from top of porch to bottom of beam is 10’-0”. The vertical member of the screening will give you the vertical proportion. Please find attached pictures and drawings in this submittal. Thank you for your consideration, Amanda Jackson Denmark Project Manager ATTACHMENT 3 ATTACHMENT 3 ATTACHMENT 3 CVR COVER SHEET & DWG INDEX DRAWING INDEX EAGEN RESIDENCE at Stock Farm Lot 45, Guilford Place Final HPC Submittal - 12.08.20 CVR S-A100 A001 A101 A102 A103 A104 A200 A201 A202 A203 A301 A401 A501 A502 A503 A504 A505 A601 E101 E102 COVER SHEET & DRAWING INDEX SURVEY ARCHITECTURAL FOUNDATION PLAN. SITE PLAN FIRST FLOOR PLAN SECOND FLOOR PLAN ROOF PLAN C.H. FLOOR PLANS OVERALL ELEVATIONS EXTERIOR ELEVATIONS EXTERIOR ELEVATIONS CH EXTERIOR ELEVATIONS BUILDING SECTIONS WALL SECTIONS DETAILS DETAILS DETAILS DETAILS WINDOW & DOOR DETAILS WINDOW & DOOR SCHEDULES FIRST FLOOR ELECTRICAL PLAN SECOND FLOOR & C.H. ELECTRICAL PLANS PROJECT TEAM GENERAL NOTES: 1. The contractor is responsible for compliance, and shall construct, to all applicable local, state, and federal codes and regulations, in conformance to all industry standards and methods of construction, and per manufacturer's recommended installations. 2. All materials will be new, unless otherwise specified. All materials, finishes, and workmanship will meet accepted industry standards, and will be consistent with the plans regarding sizes. A reasonable allowance on all dimensions is allowed according to normal industry standards. 3. For dimensions not shown or in question, the contractor will notify Architect of any discrepancies or conflicts before proceeding. 4. For discrepancies or conflicts between the architectural and engineering drawings, the contractor shall request clarification from the Architect before proceeding. 5. Contractor shall verify all existing field conditions. Any discrepancies shall be brought to the attention of the Architect. 6. Contractor to provide a sample board of exterior materials, finishes and colors for final approval by the Neighborhood/Development review board and Owner. 7. Contractor to provide a job sign in accordance with the neighborhood/development regulations. 8. The site is to be kept clean at all times for the duration of the project. 9. The design documents are instruments of professional service and shall remain the property of Pearce Scott Architects. Such instruments shall not be used by the client, or others, for any other purposes without the prior written consent of the Architect. The documents are a one-time only use. 10. The design documents are to be used for design intent and in coordination with supplemental engineering documents. 11. All walls are dimensioned to the face of stud or masonry unless noted otherwise. 12. See structural engineering documents for structural connection details and call-outs, calculation and notes required by code, and details for wall and roof connections including tie down requirements. 13. The design documents do not indicate required drainage and other site related work requirements. See landscape, civil, or other supplemental drawings. 14. When the Architect is contracted for construction observation services by the owner, the Contractor will coordinate with the Architect for progress visits based on the schedule and availability of both parties. Pay applications, if applicable, shall be provided to the Architect prior to the meeting to allow site review of work within the billing cycle. PROJECT INFORMATION AREA CALCULATIONS: (AJD - 12.04.20) MAIN HOUSE: FIRST FLOOR HEATED SECOND FLOOR HEATED MAIN HOUSE HEATED ENTRY PORCH SCREENED PORCH SIDE PORCH MAIN HOUSE UNHEATED GROSS UNDER ROOF CARRIAGE HOUSE: SECOND FLOOR HEATED GARAGE UNHEATED GROSS UNDER ROOF OVERALL PROJECT TOTAL HEATED GROSS UNDER ROOF 1,460 657 2,117 280 403 64 747 2,864 724 488 1,172 2,841 4,036 PROJECT ANALYSIS: (AJD - 10.14.20) FRONT SETBACK: REAR SETBACK: RIGHT SETBACK: LEFT SETBACK: DRIVEWAY ACCESS: MIN. FINISH FLR. ELEV.: ACTUAL FINISH FLR. ELEV.: BUILDING TYPE: 10' 25' 10' 10' STREET 3'-0" A.F.G 3'-0" A.F.G ADDITIONAL BUILDING TYPE W/ VILLAGE HOUSE CHARACTERISTICS ARCHITECT: Pearce Scott Architects H. Pearce Scott, AIA 6 State of Mind, Suite 200 Bluffton, SC 29910 P: 843.837.5700 C: 843.816.6067 E: pearce@pscottarch.com © 2020 PEARCE SCOTT ARCHITECTS PEARCE SCOTT ARCHITECTS 6 STATE OF MIND ST SUITE 200 BLUFFTON, SC 29910 843.837.5700 NEW RESIDENCE FOR: KATE EAGEN LOT 45 STOCK FARM HISTORIC DISTRICT BLUFFTON, SC 29910 DESCRIPTION / REVISION LOGNO. INITIALDATE PROJECT NO. NO. DATE 12.08.20 DRAWN BY AJD CHECKED BY AWB SHEET NO. DO NOT SCALE FROM DRAWINGSNOT FOR CONSTRUCTION 24X36 PAPER SIZE HPC CONCEPTUAL SUBMITTAL AJD10.14.20 HPC FINAL SUBMITTAL AJD12.08.20 LANDSCAPE ARCHITECT: Witmer-Jones-Keefer Dan Keefer 23 Promenade Street Bluffton, SC 29910 P: 843.757.7411 C: 843.290.5437 E: dan@wjkltd.com GENERAL CONTRACTOR: DH Abney David Abney PO Box 452 Bluffton, SC 29910 C: 843.683.7873 E: david@dhabney.com ATTACHMENT 4 ATTACHMENT 4 T.O. SLAB 6" A. FIN. GRADE 16'-0"12'-0" 23'-0"2'-6" 16'-0"12'-0" 28'-0" 28'-0" 2'-6" 28'-0" SLOPE TO DRAIN SLOPE TO DRAIN POURED CONCRETE LANDING FOR STAIRS 3'-0" LINE OF FOOTING BELOW 4'-2" 9'-8" 9'-4" 9'-3" 11'-1" 2'-2" 2'-10" 10'-0" 6'-2" 5'-3" 6'-512" 7'-112" 6'-5" 8'-01 4" 12'-3" 35'-0" 26'-8" 61'-8" 39'-4" 2'-1112" 5'-7" 2'-612" 7'-7" 7'-8" 8'-0" 34'-4" 10'-6" 28'-6" 8'-8" 7'-8" 8'-2" 12'-6" 14'-8" 10'-4" 8'-10" 8'-4" 8'-10" 5'-6"4'-6"2'-0" 2'-0" 10'-0" 14'-8" 1'-0" 8" 8" 8" 8" 1'-0" 1'-0" 7'-10" 7'-4" 7'-10" 4'-10"11'-8"8'-6" T.O. SLAB 4" A. FIN. GRADE T.O. SLAB 4" A. FIN. GRADE FOOTING BELOW TOP FINISH FLOOR 3'-0" A. FIN. GRADE TOP PORCH 2'-6" A. FIN. GRADE TOP PORCH 2'-6" A. FIN. GRADE 16X16 PIER 12X12 PIER 8X16 PIER LINE OF COLUMN ABOVE LINE OF COLUMN ABOVE 12X12 PIER 16X16 PIER 8X16 PIER 8X16 PIER LINE OF COLUMN ABOVE FOOTING BELOW 8" CMU WALL FOR FIREPLACE, VERIFY SIZE W/ MANUFACTURER, SEE STRUCTURAL 8" CMU WALL FOR FIREPLACE, VERIFY SIZE W/ MANUFACTURER, SEE STRUCTURAL 2'-8" 1. 2. 3. NOTES: ARCHITECTURAL FOUNDATION FOR EXTERIOR DIMENSIONS & LEVEL CHANGES ONLY. REFER TO STRUCTURAL FOR ALL OTHER INFORMATION. LEVEL CHANGES INDICATE TOP OF SLAB STEP UPS ONLY--SEE SECTIONS & DETAILS FOR INTENDED FINISHED FLOOR TO FINISHED FLOOR LEVEL CHANGES. CONTACT ARCHITECT IF MATERIALS CHANGE, AS THIS WILL AFFECT FINISHED FLOOR TO FINISHED FLOOR LEVEL CHANGES. REFER TO STRUCTURAL FOUNDATION PLAN FOR CONTROL JOINT LOCATIONS AND FOOTING SIZES AND DETAILS. 4. CONTRACTOR TO COORDINATE ALL FIRST FLOOR PLUMBING PRIOR TO SLAB POUR. VERIFY FLOOR OUTLET LOCATIONS PRIOR TO SLAB POUR. 5. 6. 7. ALL HARDSCAPE / PAVING, PADS, FILL & GRADING TO BE COORD. BY CONTRACTOR & LANDSCAPE ARCHITECT 1/4" = 1'-0" ARCHITECTURAL FOUNDATION PLAN 1 S-A100 ARCH. FOUND. PLAN © 2020 PEARCE SCOTT ARCHITECTS PEARCE SCOTT ARCHITECTS 6 STATE OF MIND ST SUITE 200 BLUFFTON, SC 29910 843.837.5700 NEW RESIDENCE FOR: KATE EAGEN LOT 45 STOCK FARM HISTORIC DISTRICT BLUFFTON, SC 29910 DESCRIPTION / REVISION LOGNO. INITIALDATE PROJECT NO. NO. DATE 12.08.20 DRAWN BY AJD CHECKED BY AWB SHEET NO. DO NOT SCALE FROM DRAWINGSNOT FOR CONSTRUCTION 24X36 PAPER SIZE HPC CONCEPTUAL SUBMITTAL AJD10.14.20 HPC FINAL SUBMITTAL AJD12.08.20 N ATTACHMENT 4 K-3429MEMOIRS TOILETS VITREOUS CHINA K-3429 MEMOIRS TOILETS VITREOUS CHINA K-710 IRON WORKS BATH KOHLER CAST IRON 10' BUILDING SETBACK 10' BUILDING SETBACK 10' BUILDING SETBACK 25' BUILDING SETBACK 26'-1 1 2" 8'-1 1 2" 5'-6" 31'-5 1 2" 49'-6" 35'-6" 5'-0" PROPOSED RESIDENCE PROPOSED CARRIAGE HOUSE DRIVE MOTOR COURT WALK WAY FINAL DRIVEWAY LAYOUT SEE LANDSCAPE PLAN 1/8" = 1'-0" SITE PLAN 1 A001 SITE PLAN N © 2020 PEARCE SCOTT ARCHITECTS PEARCE SCOTT ARCHITECTS 6 STATE OF MIND ST SUITE 200 BLUFFTON, SC 29910 843.837.5700 NEW RESIDENCE FOR: KATE EAGEN LOT 45 STOCK FARM HISTORIC DISTRICT BLUFFTON, SC 29910 DESCRIPTION / REVISION LOGNO. INITIALDATE PROJECT NO. NO. DATE 12.08.20 DRAWN BY AJD CHECKED BY AWB SHEET NO. DO NOT SCALE FROM DRAWINGSNOT FOR CONSTRUCTION 24X36 PAPER SIZE HPC CONCEPTUAL SUBMITTAL AJD10.14.20 HPC FINAL SUBMITTAL AJD12.08.20 ATTACHMENT 4 48" FIRE BOX K-3429 MEMOIRS TOILETS VITREOUS CHINA K-3429 MEMOIRS TOILETS VITREOUS CHINA 48" REF. DW DN DN ENTRY PORCH 100 GREAT ROOM 101 KITCHEN 102 MUDROOM / LAUNDRY 103 POWDER 104 OWNER'S BEDROOM 105 SIDE PORCH 108 SCREENED PORCH 109 101B 101D 104A 107A 106A 107B 105A 103B 103A A AA B UP ISLAND 4'-0"X8'-0" 1 2 C.O.3'X8' 2X4 UP 2 36" RANGE W D R&S STORAGE UNDER LANDING 48" FIRE BOX R&S R&S R&S OWNER'S WIC 106 H.B. K-710 IRON WORKS BATH KOHLER CAST IRON 8'-6" VANITY 5'-6" TUB 6'-2" X 4'-0" BENCH 101C 101A B 103C OWNER'S BATH 107 A 4'-7"7'-8"4'-0"4'-0" 6'-5" 11'-2"2'-5"5'-3"2'-5"3'-9" 25'-0" 20'-3"10'-0" 61'-8" 3'-8"9'-8"12'-8" 2'-2" 26'-0" 6'-6" 5'-6" 40'-2" 2'-0" 2'-0" 5'-812" 9'-312" 9'-312" 5'-812" 2'-0" 7'-312"7'-312"5'-212" 5'-212" 6'-812" 12'-512" 7'-6" 16'-10"10'-6" 8'-0"7'-8"7'-7"2'-612"5'-7"2'-1112" 8" 34'-4" 30'-0" 10'-8"9'-8"9'-4"9'-8"8" 40'-0" A AAAA B 2'-6"2'-6" 11'-6"11'-6" H.B. 6'-0" 23'-0" 12'-0" 11'-8" 4'-10" 9'-0" 9'-0" 5'-8" 6'-0" 5'-8" COVERED CONNECTOR 004 6'-10"8'-1" CL CL CL CLCL CL CLCL CL 6'-5" 4 3 3 001C 109A 109B 2'-3" 6'-11" 3'-0" 2'-312" 9'-512" 4'-612" 12'-0" 5'-512" 12'-6" 9'-2" 4'-1" 3'-1112" 7'-112" SERVICE YARD METER HVAC 1112" 3'-0" 2'-2" 3'-1112" AREA CALCULATIONS MAIN HOUSE CONDITIONED SPACE: FIRST FLOOR SECOND FLOOR TOTAL COND. UNCONDITIONED SPACE: ENTRY PORCH SCREENED PORCH SIDE PORCH TOTAL UNCOND. MAIN HOUSE TOTAL CH UNCONDITIONED: GARAGE CH CONDITIONED: STUDIO CH TOTAL OVERALL TOTAL 1,460 657 2,117 280 403 64 747 2,864 724 448 1,172 4,036 1. 5 RISERS @ +/- 6", 4 TREADS @ 11" EA. 2. 10"X10" SQUARE COLUMN 3. 8"X8" SQUARE COLUMN 4. 2'-0" X 6'-8" SHOWER DOOR WITH CURB NOTES LEGEND R&S: ROD AND SHELF C.O.: CASED OPENING H.B.: HOSE BIB 2X4: 2X4 STUD WALLS 1/4" = 1'-0" FIRST FLOOR PLAN 1 A101 FIRST FLOOR PLAN © 2020 PEARCE SCOTT ARCHITECTS PEARCE SCOTT ARCHITECTS 6 STATE OF MIND ST SUITE 200 BLUFFTON, SC 29910 843.837.5700 NEW RESIDENCE FOR: KATE EAGEN LOT 45 STOCK FARM HISTORIC DISTRICT BLUFFTON, SC 29910 DESCRIPTION / REVISION LOGNO. INITIALDATE PROJECT NO. NO. DATE 12.08.20 DRAWN BY AJD CHECKED BY AWB SHEET NO. DO NOT SCALE FROM DRAWINGSNOT FOR CONSTRUCTION 24X36 PAPER SIZE HPC CONCEPTUAL SUBMITTAL AJD10.14.20 HPC FINAL SUBMITTAL AJD12.08.20 N SEE SHEET A104 ATTACHMENT 4 K-1123 ARCHER BATHING ACRYLIC K-3429 MEMOIRS TOILETS VITREOUS CHINA R&S R&S STORAGE STAIR HALL 200 BATH 2 201 BEDROOM 2 202 BEDROOM 3 203 203A 203B 202A 202B 200A 201A 201B DN SEE ELEVATIONS FOR WINDOW HEAD HEIGHT @ THIS LOCATION 2X4 2X4 2X4 2X4 9 RISERS @ +/- 7 11/16", 8 TREADS @ 11" EA. 9 RISERS @ +/- 7 11/16", 8 TREADS @ 11" EA. DN FLUEC C D D 3'-9"10'-1112"3'-612"3'-9" 3'-0" 25'-0" 5'-6" 5'-412" 9'-412" 4'-312" 5'-512" 30'-0" 4'-812"2'-012"4'-9"7'-6"6'-0" 5'-6"6'-4"6'-4"6'-4"5'-6" 30'-0" 25'-0" C C C C D 15'-3" 14'-9" 4'-5"3'-1112"3'-112"13'-6" 7'-9" 3'-112" 4'-7" 5'-512" AREA CALCULATIONS MAIN HOUSE CONDITIONED SPACE: FIRST FLOOR SECOND FLOOR TOTAL COND. UNCONDITIONED SPACE: ENTRY PORCH SCREENED PORCH SIDE PORCH TOTAL UNCOND. MAIN HOUSE TOTAL CH UNCONDITIONED: GARAGE CH CONDITIONED: STUDIO CH TOTAL OVERALL TOTAL 1,460 657 2,117 280 403 64 747 2,864 724 448 1,172 4,036 1. 5 RISERS @ +/- 6", 4 TREADS @ 11" EA. 2. 10"X10" SQUARE COLUMN 3. 8"X8" SQUARE COLUMN 4. 2'-0" X 6'-8" SHOWER DOOR WITH CURB NOTES LEGEND R&S: ROD AND SHELF C.O.: CASED OPENING H.B.: HOSE BIB 2X4: 2X4 STUD WALLS 1/4" = 1'-0" SECOND FLOOR PLAN 1 A102 SECOND FLOOR PLAN © 2020 PEARCE SCOTT ARCHITECTS PEARCE SCOTT ARCHITECTS 6 STATE OF MIND ST SUITE 200 BLUFFTON, SC 29910 843.837.5700 NEW RESIDENCE FOR: KATE EAGEN LOT 45 STOCK FARM HISTORIC DISTRICT BLUFFTON, SC 29910 DESCRIPTION / REVISION LOGNO. INITIALDATE PROJECT NO. NO. DATE 12.08.20 DRAWN BY AJD CHECKED BY AWB SHEET NO. DO NOT SCALE FROM DRAWINGSNOT FOR CONSTRUCTION 24X36 PAPER SIZE HPC CONCEPTUAL SUBMITTAL AJD10.14.20 HPC FINAL SUBMITTAL AJD12.08.20 N ATTACHMENT 4 RIDGERIDGE PITCH BREAK PITCH BREAK HIP 8:12 SLOPE8:12 SLOPE 8:12 SLOPE8:12 SLOPE 4:12 SLOPE 4:12 SLOPE 4:12 SLOPE 4:12 SLOPE 8" 2'-0" 2'-0" 2'-0" 8" 2'-0" 2'-0" 8" 1'-0" 2'-0" 8" 2'-0" 1'-0" 2'-0" LINE OF COLUMN BELOW LINE OF FIRST FLOOR WALL BELOW LINE OF SECOND FLOOR WALL BELOW 5-V CRIMP METAL ROOF 5-V CRIMP METAL ROOF 8:12 SLOPE 8:12 SLOPE8:12 SLOPE3:12 SLOPE RIDGE 1'-0" 2'-0" 1'-0" 3'-0"2'-0" 8" 12'-6" 8" 1'-1"1'-1" 3:12 SLOPE RIDGE RIDGE 3:12 SLOPE3:12 SLOPE LINE OF COLUMN BELOW 1'-0" VALLEY VALLEY 1'-0" 1'-0" 2'-0" CRICKET CHIMNEY CRICKET CHIMNEY 8" 1/4" = 1'-0" ROOF PLAN 1 A103 ROOF PLAN © 2020 PEARCE SCOTT ARCHITECTS PEARCE SCOTT ARCHITECTS 6 STATE OF MIND ST SUITE 200 BLUFFTON, SC 29910 843.837.5700 NEW RESIDENCE FOR: KATE EAGEN LOT 45 STOCK FARM HISTORIC DISTRICT BLUFFTON, SC 29910 DESCRIPTION / REVISION LOGNO. INITIALDATE PROJECT NO. NO. DATE 12.08.20 DRAWN BY AJD CHECKED BY AWB SHEET NO. DO NOT SCALE FROM DRAWINGSNOT FOR CONSTRUCTION 24X36 PAPER SIZE HPC CONCEPTUAL SUBMITTAL AJD10.14.20 HPC FINAL SUBMITTAL AJD12.08.20 N ATTACHMENT 4 K-3429 MEMOIRS TOILETS VITREOUS CHINA R&S DN STUDIO 002 STUDIO BATH 003 16'-0" 4'-2" 8'-0"8'-0" D D 28'-0" D 8'-0"8'-0" 16'-0" 28'-0" 002A 18 RISERS @ +/- 7 3/16", 17 TREADS @ 11" EA. 2X4 5'-0" 14'-0" 2X4 14'-0" 24" REF. STACKED W/D BENCH MICRO 2X4 2X42X4 2X4 R&S 4 002B 002C 003A 003B AREA CALCULATIONS MAIN HOUSE CONDITIONED SPACE: FIRST FLOOR SECOND FLOOR TOTAL COND. UNCONDITIONED SPACE: ENTRY PORCH SCREENED PORCH SIDE PORCH TOTAL UNCOND. MAIN HOUSE TOTAL CH UNCONDITIONED: GARAGE CH CONDITIONED: STUDIO CH TOTAL OVERALL TOTAL 1,460 657 2,117 280 403 64 747 2,864 724 448 1,172 4,036 1. 5 RISERS @ +/- 6", 4 TREADS @ 11" EA. 2. 10"X10" SQUARE COLUMN 3. 8"X8" SQUARE COLUMN 4. 2'-0" X 6'-8" SHOWER DOOR WITH CURB NOTES LEGEND R&S: ROD AND SHELF C.O.: CASED OPENING H.B.: HOSE BIB 2X4: 2X4 STUD WALLS R&S A 3'-8"9'-8"12'-8" 26'-0" 40'-2" A GARAGE 001 28'-0" UP 16'-0"12'-0" 2'-6"2'-6" B 8'-0"8'-0" 001A 001B 11'-6"11'-6" 5'-0"5'-8"5'-8"11'-8" CL 28'-0" H.B. 6'-0" 6'-0" 23'-0" 12'-0" 16'-0" B 12'-0" 9'-0" 5'-8" 6'-0" 5'-8" 6'-10"8'-1" CL 6'-5" 3 3 001C SERVICE YARD TRASH HVAC 1/4" = 1'-0" FIRST FLOOR PLAN 1 A104 C.H. FLOOR PLANS © 2020 PEARCE SCOTT ARCHITECTS PEARCE SCOTT ARCHITECTS 6 STATE OF MIND ST SUITE 200 BLUFFTON, SC 29910 843.837.5700 NEW RESIDENCE FOR: KATE EAGEN LOT 45 STOCK FARM HISTORIC DISTRICT BLUFFTON, SC 29910 DESCRIPTION / REVISION LOGNO. INITIALDATE PROJECT NO. NO. DATE 12.08.20 DRAWN BY AJD CHECKED BY AWB SHEET NO. DO NOT SCALE FROM DRAWINGSNOT FOR CONSTRUCTION 24X36 PAPER SIZE HPC CONCEPTUAL SUBMITTAL AJD10.14.20 HPC FINAL SUBMITTAL AJD12.08.20 N 1/4" = 1'-0" SECOND FLOOR PLAN 2 SEE SHEET A101 ATTACHMENT 4 A200 OVERALL ELEVATIONS © 2020 PEARCE SCOTT ARCHITECTS PEARCE SCOTT ARCHITECTS 6 STATE OF MIND ST SUITE 200 BLUFFTON, SC 29910 843.837.5700 NEW RESIDENCE FOR: KATE EAGEN LOT 45 STOCK FARM HISTORIC DISTRICT BLUFFTON, SC 29910 DESCRIPTION / REVISION LOGNO. INITIALDATE PROJECT NO. NO. DATE 12.08.20 DRAWN BY AJD CHECKED BY AWB SHEET NO. DO NOT SCALE FROM DRAWINGSNOT FOR CONSTRUCTION 24X36 PAPER SIZE HPC CONCEPTUAL SUBMITTAL AJD10.14.20 HPC FINAL SUBMITTAL AJD12.08.20 1/8" = 1'-0" LEFT ELEVATION W/ CONNECTOR 1 1/8" = 1'-0" RIGHT ELEVATION W/ CONNECTOR 2 ATTACHMENT 4 HORIZONTAL LAP SIDING W/ 7" EXPOSURE, TYP. EXPOSED RAFTER TAILS, TYP. 2X6 TRIM BAND 2X6 TRIM BAND TO ACT AS WINDOW SILL 5V CRIMP METAL ROOF CRICKET TABBY STUCCO CHIMNEY 2X WATER TABLE & SKIRT BOARD TABBY STUCCO PIERS 5/4X6 WOOD UNDERPINNING WOOD HANDRAILS & STEPS WOOD DECKING DECORATIVE GABLE END BRACKET 10X10 WOOD COLUMN T.O. SUBFLOOR +/- 2'-11 1/4" GRADE T.O. PORCH 514" 8'-03 4" 10'-0" 11'-6" T.O. DOOR T.O. SUBFLOOR 9'-10" B.O. BEAM T.O. WINDOW 8'-03 4" T.O. PLATE 9'-103 4" 8 12 4 12 2X6 CORNER BOARD VERTICAL BOARD AND BATTEN 12" O.C. 4'-6" 4 A503 C C C C T.O. SUBFLOOR +/- 2'-11 1/4" GRADE 8'-03 4" 11'-6" T.O. WINDOW 8'-03 4" T.O. SUBFLOOR T.O. WINDOW T.O. PLATE 9'-53 4" 9'-103 4" 4'-6" T.O. PLATE 10'-912" 4'-0" 10'-0" B.O. BEAM 4 12 4 12 8 12 4 12 10X10 WOOD COLUMN TABBY STUCCO CHIMNEY 2X6 TRIM BAND 2X6 TRIM BAND 2X WATER TABLE & SKIRT BOARD HORIZONTAL LAP SIDING W/ 7" EXPOSURE, TYP. TABBY STUCCO PIERS 2X6 CORNER BOARD VERTICAL BOARD AND BATTEN 12" O.C. CRICKET 2X6 TRIM BAND VERTICAL BOARD AND BATTEN 12" O.C. 5/4X6 WOOD UNDERPINNING WOOD HANDRAILS & STEPS CRICKET DECORATIVE GABLE END BRACKET 8 12 COVERED CONNECTOR 3 12 D A A 1/4" = 1'-0" FRONT ELEVATION 1 1/4" = 1'-0" REAR ELEVATION 2 A201 EXTERIOR ELEVATIONS © 2020 PEARCE SCOTT ARCHITECTS PEARCE SCOTT ARCHITECTS 6 STATE OF MIND ST SUITE 200 BLUFFTON, SC 29910 843.837.5700 NEW RESIDENCE FOR: KATE EAGEN LOT 45 STOCK FARM HISTORIC DISTRICT BLUFFTON, SC 29910 DESCRIPTION / REVISION LOGNO. INITIALDATE PROJECT NO. NO. DATE 12.08.20 DRAWN BY AJD CHECKED BY AWB SHEET NO. DO NOT SCALE FROM DRAWINGSNOT FOR CONSTRUCTION 24X36 PAPER SIZE HPC CONCEPTUAL SUBMITTAL AJD10.14.20 HPC FINAL SUBMITTAL AJD12.08.20 ATTACHMENT 4 VERTICAL BOARD AND BATTEN 12" O.C. T.O. SUBFLOOR +/- 2'-11 1/4" GRADE T.O. PORCH 51 4" 8'-03 4" 11'-6" T.O. WINDOW / DOOR T.O. SUBFLOOR T.O. WINDOW 8'-03 4" 10'-0" B.O. BEAM 12'-6" +/- 13'-1012" HORIZONTAL LAP SIDING W/ 7" EXPOSURE, TYP. 10X10 WOOD COLUMN EXPOSED RAFTER TAILS, TYP. 5V CRIMP METAL ROOF 2X WATER TABLE & SKIRT BOARD TABBY STUCCO PIERS 2X6 CORNER BOARD 5/4X6 WOOD UNDERPINNING 10X10 COLUMNWOOD HANDRAILS & STEPS WOOD DECKING SCREEN NOT SHOWN 2X6 TRIM BAND TABBY STUCCO CHIMNEY 5V CRIMP METAL ROOF 5 A503 COVERED CONNECTOR NOT SHOWN 4 12 D C B BAAA T.O. SUBFLOOR +/- 2'-11 1/4" GRADE T.O. PORCH 514" 8'-03 4" 11'-6" T.O. WINDOW T.O. SUBFLOOR T.O. WINDOW 8'-03 4" 13'-6" +/- 22'-112" HORIZONTAL LAP SIDING W/ 7" EXPOSURE, TYP. EXPOSED RAFTER TAILS, TYP. 5 V CRIMP METAL ROOF TABBY STUCCO CHIMNEY 2X WATER TABLE & SKIRT BOARD TABBY STUCCO PIERS 2X6 CORNER BOARD VERTICAL BOARD AND BATTEN 12" O.C. 2X6 TRIM BAND TO ACT AS WINDOW SILL WOOD DECKING SCREEN NOT SHOWNWOOD HANDRAILS & STEPS 5/4X6 WOOD UNDERPINNING VERTICAL BOARD AND BATTEN 12" O.C. 10X10 COLUMN 10'-0" B.O. BEAM 4 12 C D BA AAA 2 A503 5'-6" 1/4" = 1'-0" LEFT ELEVATION 1 1/4" = 1'-0" RIGHT ELEVATION 2 A202 EXTERIOR ELEVATIONS © 2020 PEARCE SCOTT ARCHITECTS PEARCE SCOTT ARCHITECTS 6 STATE OF MIND ST SUITE 200 BLUFFTON, SC 29910 843.837.5700 NEW RESIDENCE FOR: KATE EAGEN LOT 45 STOCK FARM HISTORIC DISTRICT BLUFFTON, SC 29910 DESCRIPTION / REVISION LOGNO. INITIALDATE PROJECT NO. NO. DATE 12.08.20 DRAWN BY AJD CHECKED BY AWB SHEET NO. DO NOT SCALE FROM DRAWINGSNOT FOR CONSTRUCTION 24X36 PAPER SIZE HPC CONCEPTUAL SUBMITTAL AJD10.14.20 HPC FINAL SUBMITTAL AJD12.08.20 ATTACHMENT 4 +/- 6" GRADE 8'-0" 10'-111 4" T.O. SLAB T.O. SUBFLOOR T.O. WINDOW 7'-03 4" T.O. DOOR HORIZONTAL LAP SIDING W/ 7" EXPOSURE, TYP. VERTICAL BOARD AND BATTEN 12" O.C. 2X6 TRIM BAND TO ACT AS WINDOW SILL EXPOSED RAFTER TAILS, TYP. METAL ROOF 8 12 2 A502 COVERED CONNECTOR 3 12 8X8 COLUMN GRADE T.O. WALK B.O. BEAM 9'-0"4" D +/- 6" GRADE 9'-6" 10'-1114" T.O. SLAB T.O. SUBFLOOR T.O. DOOR B.O. BEAM 7'-03 4" 3'-03 4" EXPOSED RAFTER TAILS, TYP. 5V CRIMP METAL ROOF 8 12 8X8 COLUMNWOOD HANDRAILS & STEPS HORIZONTAL LAP SIDING W/ 7" EXPOSURE, TYP. VERTICAL BOARD AND BATTEN 12" O.C. 2X6 TRIM BAND 2X6 CORNER BOARD 5 A503 5'-0" 3 12 +/- 6" GRADE 9'-612" T.O. SLAB T.O. PLATE T.O. DOOR 8'-0" VERTICAL BOARD AND BATTEN 12" O.C. 2X6 TRIM BAND TO ACT AS WINDOW SILL DECORATIVE GABLE END BRACKET 8 12 4'-6" METAL ROOF 2X6 CORNER BOARD D 3 12 +/- 6" GRADE 314" 10'-1114" T.O. SLAB T.O. WINDOW 7'-03 4" T.O. WINDOW T.O. PLATE 8'-0" T.O. SUBFLOOR T.O. PORCH 9'-012" HORIZONTAL LAP SIDING W/ 7" EXPOSURE, TYP. 2X6 CORNER BOARD VERTICAL BOARD AND BATTEN 12" O.C. DECORATIVE GABLE END BRACKET 8 12 4'-6" WOOD HANDRAIL 8X8 COLUMN 2X6 TRIM BAND TO ACT AS WINDOW SILL D B B 1/4" = 1'-0" FRONT ELEVATION 1 1/4" = 1'-0" REAR ELEVATION 2 A203 CH EXTERIOR ELEVATIONS © 2020 PEARCE SCOTT ARCHITECTS PEARCE SCOTT ARCHITECTS 6 STATE OF MIND ST SUITE 200 BLUFFTON, SC 29910 843.837.5700 NEW RESIDENCE FOR: KATE EAGEN LOT 45 STOCK FARM HISTORIC DISTRICT BLUFFTON, SC 29910 DESCRIPTION / REVISION LOGNO. INITIALDATE PROJECT NO. NO. DATE 12.08.20 DRAWN BY AJD CHECKED BY AWB SHEET NO. DO NOT SCALE FROM DRAWINGSNOT FOR CONSTRUCTION 24X36 PAPER SIZE HPC CONCEPTUAL SUBMITTAL AJD10.14.20 HPC FINAL SUBMITTAL AJD12.08.20 1/4" = 1'-0" RIGHT ELEVATION 4 1/4" = 1'-0" LEFT ELEVATION 3 ATTACHMENT 4 T.O. FIN. FLOOR +/- 3'-0" GRADE T.O. PORCH 6" 8'-0" 11'-514" T.O. WINDOW / DOOR T.O. SUBFLOOR T.O. WINDOW / DOOR 8'-03 4" T.O. PLATE 9'-103 4" 10X10 COLUMN 8 12 4 12 TO LAUNDRY KITCHEN ISLAND KITCHEN 102 TO HALL BEDROOM 2 202 BEDROOM 3 203 TO STAIR HALL TO STAIR HALL TO CLOSET TO CLOSET STORAGE UNDER STAIR, FIELD ADJUST HANDRAIL TBD BY OWNER 16" FLOOR SYSTEM 2X COLLAR TIE, SEE STRUCTURAL INTERIOR SUPPORT AS REQUIRED BY STRUCTURAL 2X8 CEILING FRAMING 2X8 ROOF FRAMING 2X8 ROOF FRAMING ATTIC 2X8 ROOF FRAMING 2X8 CEILING FRAMING SCREENED PORCH 109 10'-0" 9'-0" TO STUDIO BATH CLOSET STUDIO 002 GARAGE 001 T.O. SLAB +/- 6" GRADE 10'-111 4" T.O. SUBFLOOR T.O. PORCH 31 4" T.O. PLATE 9'-11 4" 7'-03 4"8'-0" T.O. SLAB GRADE T.O. PLATE +/- 6" 9'-612" 8 12 2X8 ROOF FRAMING 2X8 CEILING FRAMING 2X8 ROOF FRAMING 2X8 ROOF FRAMING 2X8 CEILING FRAMING16" FLOOR SYSTEM 5/8 TYPE "X" GYP. 3 12 9'-6" 9'-0" 3 A501 A301 BUILDING SECTIONS © 2020 PEARCE SCOTT ARCHITECTS PEARCE SCOTT ARCHITECTS 6 STATE OF MIND ST SUITE 200 BLUFFTON, SC 29910 843.837.5700 NEW RESIDENCE FOR: KATE EAGEN LOT 45 STOCK FARM HISTORIC DISTRICT BLUFFTON, SC 29910 DESCRIPTION / REVISION LOGNO. INITIALDATE PROJECT NO. NO. DATE 12.08.20 DRAWN BY AJD CHECKED BY AWB SHEET NO. DO NOT SCALE FROM DRAWINGSNOT FOR CONSTRUCTION 24X36 PAPER SIZE HPC CONCEPTUAL SUBMITTAL AJD10.14.20 HPC FINAL SUBMITTAL AJD12.08.20 1/4" = 1'-0" C.H.BUILDING SECTION 2 1/4" = 1'-0" BUILDING SECTION 1 ATTACHMENT 4 T.O. SUBFLOOR GRADE +/- 2'-11 1/4" SET T.O. FIN. FLOOR 3'-0" ABOVE FIN. GRADE 6 A501 T.O. PLATE 8 12 9'-10 3/4" 2'-0" 1 A501 2X6 STUD WALL @ 16" O.C. W/ BATT INSULATION 16" FLOOR SYSTEM 2X BLOCKING AS NEEDED FOR TRIM 11'-6" 10'-0" 1/2" GYPSUM BOARD 1/2" GYPSUM BOARD 3/4" PLYWOOD SUBFLOOR T.O. SUBFLOOR 3'-0 3/4" HORIZONTAL LAP SIDING W/ 7" EXPOSURE, TYP. VERTICAL BOARD AND BATTEN 12" O.C. FLASHING 2X6 W/ CHAMFER, OVER BLOCKING 2X6 BASE PLATE FINISHED FLOOR +/- 6" GRADE T.O. SUBFLOOR 5 A501 10'-11 1/4" 9'-6" T.O. SUBFLOOR T.O. PLATE 8 12 2'-0" 9'-1 1/4" 9'-0" 2X6 STUD WALL @ 16" O.C. W/ BATT INSULATION 16" FLOOR SYSTEM 2X BLOCKING AS NEEDED FOR TRIM 1/2" GYPSUM BOARD 1/2" GYPSUM BOARD 3/4" PLYWOOD SUBFLOOR 3'-0 3/4" HORIZONTAL LAP SIDING W/ 7" EXPOSURE, TYP. VERTICAL BOARD AND BATTEN 12" O.C. FLASHING 2X6 W/ CHAMFER, OVER BLOCKING 2X6 BASE PLATE FINISHED FLOOR 4 A501 T.O. SUBFLOOR GRADE +/- 2'-11 1/4" 10'-10" T.O. PLATE SET T.O. FIN. FLOOR 3'-0" ABOVE FIN. GRADE 8 12 2'-0" 2 A501 6 A501 A401 WALL SECTIONS © 2020 PEARCE SCOTT ARCHITECTS PEARCE SCOTT ARCHITECTS 6 STATE OF MIND ST SUITE 200 BLUFFTON, SC 29910 843.837.5700 NEW RESIDENCE FOR: KATE EAGEN LOT 45 STOCK FARM HISTORIC DISTRICT BLUFFTON, SC 29910 DESCRIPTION / REVISION LOGNO. INITIALDATE PROJECT NO. NO. DATE 12.08.20 DRAWN BY AJD CHECKED BY AWB SHEET NO. DO NOT SCALE FROM DRAWINGSNOT FOR CONSTRUCTION 24X36 PAPER SIZE HPC CONCEPTUAL SUBMITTAL AJD10.14.20 HPC FINAL SUBMITTAL AJD12.08.20 1" = 1'-0" C.H. 2 STORY WALL SECTION 3 1" = 1'-0" 2 STORY WALL SECTION 11" = 1'-0" 1 STORY WALL SECTION 2 ATTACHMENT 4 HURRICANE CLIP @ EA. RAFTER 2X8 RAFTERS @ 16" O.C., SEE STRUCTURAL SPRAY FOAM INSULATION AT ALL ROOFS, TYP. METAL DRIP EDGE 5-V CRIMP METAL ROOF OVER ICE AND WATER SHIELD EXTERIOR ROOF SHEATHING 1X4 TRIM 2'-0", TYP. 1X4 HARDIE SOFFIT 5/4X TRIM OVER BLOCKING (2) 2X6 TOP PLATE 2X8 CEILING FRAMING 8 12NOTE: PER CODE, RAFTER NOTCH CANNOT EXCEED 25% DEPTH OF RAFTER 1/3 2/3 P.T. 2X6 SISTERED ON EXPOSED RAFTER W/ 13 EXPOSURE 1/2" GYPSUM BOARD 2X6 TOP PLATE HURRICANE CLIP @ EA. RAFTER 2X8 RAFTERS @ 16" O.C., SEE STRUCTURAL SPRAY FOAM INSULATION AT ALL ROOFS, TYP. METAL DRIP EDGE 5-V CRIMP METAL ROOF OVER ICE AND WATER SHIELD EXTERIOR ROOF SHEATHING 1X4 TRIM 2'-0", TYP. 1X4 HARDIE SOFFIT 5/4X TRIM OVER BLOCKING (2) 2X6 TOP PLATE 2X8 CEILING FRAMING 2X6 TOP PLATE 8 12NOTE: PER CODE, RAFTER NOTCH CANNOT EXCEED 25% DEPTH OF RAFTER 1/3 2/3 P.T. 2X6 SISTERED ON EXPOSED RAFTER W/ 13 EXPOSURE 3/4" PLYWOOD SUBFLOOR 1/2" GYPSUM BOARD HURRICANE CLIP @ EA. RAFTER 2X8 RAFTERS @ 16" O.C., SEE STRUCTURAL SPRAY FOAM INSULATION AT ALL ROOFS, TYP. METAL DRIP EDGE 5-V CRIMP METAL ROOF OVER ICE AND WATER SHIELD EXTERIOR ROOF SHEATHING 1X4 TRIM 2'-0", TYP. 1X4 HARDIE SOFFIT 5/4X TRIM OVER BLOCKING (2) 2X6 TOP PLATE 2X8 CEILING FRAMING 8 12NOTE: PER CODE, RAFTER NOTCH CANNOT EXCEED 25% DEPTH OF RAFTER 1/3 2/3 P.T. 2X6 SISTERED ON EXPOSED RAFTER W/ 13 EXPOSURE 1/2" GYPSUM BOARD 2X6 BASE PLATE 2X BLOCKING AS NEEDED FOR TRIM 2X6 STUD WALL @ 16" O.C. W/ BATT INSULATION SIDING -SEE ELEVATIONS MOISTURE BARRIER OVER 1/2" EXTERIOR SHEATHING 3/4" PLYWOOD SUBFLOOR FINISHED FLOOR 2X FLOOR JOISTS, SEE STRUCTURAL CONTINUOUS METAL FLASHING - LAP MOISTURE BARRIER OVER FLASHING SEALANT - UNDER FLASHING 2" FOUNDATION, SEE STRUCTURAL TABBY STUCCO FINISH CONT. METAL WEEP SCREED CASING BEAD, TYP. HARDIE 2X6 RIPPED IN HALF, CHAMFERED 2X12 SKIRT BOARD 30° P.T. 2X STARTER STRIP W/ METAL FLASHING MOISTURE BARRIER OVER 1/2" EXTERIOR SHEATHING ANCHOR BOLT PER STRUCTURAL BLOCKING AS REQ'D FOR TRIM INTERIOR WALL FINISH P.T. STARTER STRIP FOUNDATION, SEE STRUCTURAL GRADE - SLOPE TO DRAIN P.T. 2X6 BASE PLATE +/- 6" CONTINUOUS METAL FLASHING, LAP MOISTURE BARRIER OVER FLASHING EXTEND UP WALL MIN. 16" SIDING, SEE ELEVATION 2X6 STUD WALL @ 16" O.C. HURRICANE CLIP @ EA. RAFTER 2X8 RAFTERS @ 16" O.C., SEE STRUCTURAL SPRAY FOAM INSULATION AT ALL ROOFS, TYP. METAL DRIP EDGE 5-V CRIMP METAL ROOF OVER ICE AND WATER SHIELD EXTERIOR ROOF SHEATHING 1X4 TRIM 1'-0", TYP. 1X4 HARDIE SOFFIT 5/4X TRIM OVER BLOCKING (2) 2X6 TOP PLATE 2X8 CEILING FRAMING 3 12 NOTE: PER CODE, RAFTER NOTCH CANNOT EXCEED 25% DEPTH OF RAFTER P.T. 2X6 SISTERED ON EXPOSED RAFTER W/ 13 EXPOSURE 1/2" GYPSUM BOARD 1/3 2/3 A501 DETAILS © 2020 PEARCE SCOTT ARCHITECTS PEARCE SCOTT ARCHITECTS 6 STATE OF MIND ST SUITE 200 BLUFFTON, SC 29910 843.837.5700 NEW RESIDENCE FOR: KATE EAGEN LOT 45 STOCK FARM HISTORIC DISTRICT BLUFFTON, SC 29910 DESCRIPTION / REVISION LOGNO. INITIALDATE PROJECT NO. NO. DATE 12.08.20 DRAWN BY AJD CHECKED BY AWB SHEET NO. DO NOT SCALE FROM DRAWINGSNOT FOR CONSTRUCTION 24X36 PAPER SIZE HPC CONCEPTUAL SUBMITTAL AJD10.14.20 HPC FINAL SUBMITTAL AJD12.08.20 8:12 EAVE DETAIL @ 2 STORY 1 1 1/2" = 1'-0" 8:12 EAVE DETAIL @ 1 STORY 2 1 1/2" = 1'-0" 8:12 EAVE DETAIL @ C.H. 4 1 1/2" = 1'-0" TYP. FOUNDATION DETAIL 6 1 1/2" = 1'-0" 3:12 EAVE DETAIL @ C.H. 3 1 1/2" = 1'-0" FOUNDATION DETAIL @ C.H. 5 1 1/2" = 1'-0" ATTACHMENT 4 P.T. 2X4 NAILED TO SILL PLATE VERTICAL P.T. 1X6 W/ EQ. 1" GAP SPACING, INSTALL AFTER STUCCO TABBY STUCCO TO WRAP CMU BLOCK GAP @ FINISH GRADE FOR DRAINAGE COLUMN BEYOND GALV. RODENT SCREENING, MIN. 6" UNDER GROUND 2" 5/4X DECKING 5/4 X TRIM OVER P.T. BLOCKING 3" FOUNDATION, SEE STRUCTURAL 3 12 10" 2X RAFTERS @ 16" O.C., SEE STRUCTURAL ROOF MATERIAL OVER ICE & WATER SHIELD, SEE ELEVATIONS EXTERIOR ROOF SHEATHING BEAM , SEE STRUCTURAL 5/4X TRIM OVER BLOCKING 2'-0" 10" 1X4 HARDIE SOFFIT 5/4X TRIM 2X TRIM FLASHING HURRICANE CLIP @ EA. RAFTER 2X FLOOR JOIST @ 16" O.C., SEE STRUCTURAL 5/4X T&G DECKING SLOPE TO DRAIN COUPLER MITRED CORNERS 2X COLUMN 1" 2X4 SEAT TIE-DOWN SYSTEM, SEE STRUCTURAL P.T. 2X4 COLUMN BASE TERMITE SHIELD P.T. 2X PLATETABBY STUCCO 5/4 X TRIM OVER P.T. BLOCKING PORCH BEAM, SEE STRUCTURAL TIE-DOWN SYSTEM, SEE STRUCTURAL 5/4X10 BASE TRIM P.T. 2X4 FRAME METAL DRIP EDGE 1X4 HARDIE TRIM SISTERED ON EXPOSED RAFTER TAILS ALIGN "SCREENTIGHT" CHANNEL SCREEN FRAME BEYOND PT 2X4 FRAME COLUMN BEYOND, AS PER ELEVATION SCREEN 10" "SCREENTIGHT" CHANNEL 8" X 8" COLUMN, TYP. P.T. 2X4 FRAME CONT. P.T. 2X4 "SCREENTIGHT" CHANNEL PROVIDE 1/2" X 3" OPENINGS CENTERED ON EA. PANEL & 2'-0" O.C. TO ALLOW WATER TO DRAIN 21 2" T.O. DECK SCREEN INTERIOR EXTERIOR P.T. 2X6 DRINK RAIL "SCREENTIGHT" CHANNEL 2'-6" SCREEN SCREEN FRAMING BEYOND PLAN VIEW VERTICAL "SCREENTIGHT" CHANNEL BEYOND 3"21 2" 2" 51 2" (2) 3 4" DIA. LAG SCREWS (MIN. 4" PEN. IN TO BLOCKING), PLUG WITH LIKE WOOD P.T. 6X6 BRACKET P.T. 2X6 VERTICAL WALL SUPPORT @ EA. BRACKET (2) 2X P.T. BLOCKING @ EA. BRACKET P.T. 6X6 BRACKET, CUT TO SHAPE 12 P.T. 8X8 BEAM 2X8 RAFTER 51 2" 3'-2" 5/4X 10 TRIM OVER P.T. 2X CONT. LEDGER HANGER 1 2" DIA. LAG SCREW (MIN. 2.5" PEN. INTO 6X6), PLUG WITH LIKE WOOD 5 8" DIA. GALV. THRU BOLT (COUNTERSINK) 1 2" DIA. LAG SCREW (MIN. 2.5" PEN.) 2'-0" (2) 2X P.T. BLOCKING @ EA. BRACKET 1X4 HARDIE SOFFIT P.T. 2X6 METAL DRIP EDGE 3'-0" 3" 45° EXPOSED RAFTER TAIL 8 HURRICANE CLIP @ EA. RAFTER 1X4 HARDIE TRIM 3" 3"21 2" A502 DETAILS © 2020 PEARCE SCOTT ARCHITECTS PEARCE SCOTT ARCHITECTS 6 STATE OF MIND ST SUITE 200 BLUFFTON, SC 29910 843.837.5700 NEW RESIDENCE FOR: KATE EAGEN LOT 45 STOCK FARM HISTORIC DISTRICT BLUFFTON, SC 29910 DESCRIPTION / REVISION LOGNO. INITIALDATE PROJECT NO. NO. DATE 12.08.20 DRAWN BY AJD CHECKED BY AWB SHEET NO. DO NOT SCALE FROM DRAWINGSNOT FOR CONSTRUCTION 24X36 PAPER SIZE HPC CONCEPTUAL SUBMITTAL AJD10.14.20 HPC FINAL SUBMITTAL AJD12.08.20 COLUMN DETAIL 1 1 1/2" = 1'-0" SCREEN DETAIL 3 1 1/2" = 1'-0" BRACKET DETAIL 2 1 1/2" = 1'-0" ATTACHMENT 4 1'-0" METAL DRIP EDGE P.T. 2X FLY RAFTERS 1X4 HARDIE SOFFIT SIDING, SEE ELEVATIONS P.T. 2X OUTLOOKERS @ 24" O.C. TRIM/RAFTER TO CREATE FRIEZE TO EXTEND DOWN FACE OF GABLE END 31 2" 1X4 HARDIE TRIM METAL ROOF OVER ICE & WATER SHIELD EXTERIOR ROOF SHEATHING 4"SEE ELEVATIONS3" 4" CONC. SLAB WITH W.W.M. REINFORCING. TURN DOWN SLAB AT EDGES HORIZONTAL P.T. 1X6, BOTH SIDES VERTICAL P.T. 1X6, ALTERNATE SIDES FOR VENTILATION 3X6 P.T. TOP RAIL, DOUBLE SLOPED TOP 3X8 P.T. NEWEL CAP ON 6X6 POST (SLOPED ON ALL 4 SIDES) 51 2" 1"1" 3 4"13 4" FRONT SIDE SIMPSON CONCEALED POST TIE HORIZONTAL P.T. 1X6, BOTH SIDES 1"11 2" P.T. 2X4 FRAME HORIZONTAL P.T. 2X4 AS NEEDED FOR STABILITY SIDING REF ELEVATAIONS 1/2" SHEATHING 2X TRIM FULL MEMBER TO FACE BITUMEN SPLINE ON SHEATHING - MOISTURE BARRIER EXTEND 12" EACH DIRECTION 51 2" THERMAL INSULATION 51 2" INTERIOR SPARK ARRESTOR PER MANUFACTURER RECOMMENDATION FOR METAL FLUE STUCCO VENEER +/- 2'-6" 1" 1" 4" 73 4" +/- 1'-7 1 4" 7 1 4" 51 2" 3" STUCCO VENEER R1'-7 34" 4X4 P.T. NEWEL POST W/ CAP 5/4 X TREADS & RISERS P.T. 2X4 TOP RAIL, DOUBLE SLOPED TOP 3'-0" +/- 6" 1" 11" 6" 1"3'-0" NUMBER OF STEPS DETERMINED BY FINAL GRADING P.T. 2X4 TOP RAIL, DOUBLE SLOPED TOP P.T. HORIZONTAL 1X4 BOARDS P.T. 1X4 1" 2 1 4" 3'-0" 4X4 P.T. NEWEL POST W/ CAP 5/4 X TREADS & RISERS 3'-0"+/- 6" 1" 11" 6" P.T. 2X4 TOP RAIL, DOUBLE SLOPED TOP 2" TYP. NUMBER OF STEPS DETERMINED BY FINAL GRADING LOCATION: CARRIAGE HOUSELOCATION: MAIN HOUSE +/- 2" 2" P.T. 5/4X6 W/ EQ. 1" GAP SPACING, INSTALL AFTER STUCCO GALV. RODENT SCREENING, MIN. 18" UNDER GROUND GAP @ FINISH GRADE FOR DRAINAGE 1" 11 2" TABBY STUCCO P.T. 2X4 NAILED TO SILL PLATE P.T. 2X4 FRAME SCREWED TO CMU BLOCK @ PIERS FOUNDATION, SEE STRUCTURAL A503 DETAILS © 2020 PEARCE SCOTT ARCHITECTS PEARCE SCOTT ARCHITECTS 6 STATE OF MIND ST SUITE 200 BLUFFTON, SC 29910 843.837.5700 NEW RESIDENCE FOR: KATE EAGEN LOT 45 STOCK FARM HISTORIC DISTRICT BLUFFTON, SC 29910 DESCRIPTION / REVISION LOGNO. INITIALDATE PROJECT NO. NO. DATE 12.08.20 DRAWN BY AJD CHECKED BY AWB SHEET NO. DO NOT SCALE FROM DRAWINGSNOT FOR CONSTRUCTION 24X36 PAPER SIZE HPC CONCEPTUAL SUBMITTAL AJD10.14.20 HPC FINAL SUBMITTAL AJD12.08.20 RAKE DETAIL 1 1 1/2" = 1'-0" SERVICE YARD 2 1 1/2" = 1'-0" STEPS / HANDRAIL DETAIL 5 1 1/2" = 1'-0" CORNER BOARD DETAIL 3 3" = 1'-0" CHIMNEY DETAIL 4 1" = 1'-0" UMDERPINNING DETAIL 6 1" = 1'-0" ATTACHMENT 4 GRADE B.O. BEAM T.O. SLAB +/- 4" 3 12 2 A504 6'-10" +/- 9'-0" 3 12 ROOF MATERIAL OVER ICE & WATER SHIELD, SEE ELEVATIONS EXTERIOR ROOF SHEATHING BEAM , SEE STRUCTURAL 5/4X TRIM OVER BLOCKING HURRICANE CLIP @ EA. RAFTER 1X4 HARDIE TRIM SISTERED ON EXPOSED RAFTER TAILS EXPOSED 2X8 ROOF FRAMING @ 16" O.C., SEE STRUCTURAL 1X4 HARDIE SOFFIT METAL DRIP EDGE P.T. 2X6 1'-0" 8" 1X TRIM ON UNDERSIDE OF BEAM 8" 1X4 CEILING 1/3 2/3 8X8 COLUMN NOTE: PER CODE, RAFTER NOTCH CANNOT EXCEED 25% DEPTH OF RAFTER 5/4X TRIM OVER BLOCKING ADJUST HEIGHT AS NEEDED TO ENSURE SOFFIT & FASCIA ALIGN W/ 1 STORY GARAGE PORTION A504 DETAILS © 2020 PEARCE SCOTT ARCHITECTS PEARCE SCOTT ARCHITECTS 6 STATE OF MIND ST SUITE 200 BLUFFTON, SC 29910 843.837.5700 NEW RESIDENCE FOR: KATE EAGEN LOT 45 STOCK FARM HISTORIC DISTRICT BLUFFTON, SC 29910 DESCRIPTION / REVISION LOGNO. INITIALDATE PROJECT NO. NO. DATE 12.08.20 DRAWN BY AJD CHECKED BY AWB SHEET NO. DO NOT SCALE FROM DRAWINGSNOT FOR CONSTRUCTION 24X36 PAPER SIZE HPC CONCEPTUAL SUBMITTAL AJD10.14.20 HPC FINAL SUBMITTAL AJD12.08.20 COVERED CONNECTOR SECTION 1 1 1/2" = 1'-0" EAVE DETAIL 2 1 1/2" = 1'-0" ATTACHMENT 4 2X STUD WALL @ 16" O.C. W/ THERMAL INSULATION INTERIOR WALL FINISH HEADER, SEE STRUCTURAL 5/4X6 CASING P.T. SHIM W/ THERMAL INSULATION BETWEEN SHIMS JAMB CASING BEYOND 3 4" 2X CAP W/ CHAMFER SEALANT BETWEEN FLASHING AND CAP 3 4" 3 4" 2" SIDING - REF. ELEVATIONS SEALANT UNDER FLASHING WINDOW/DOOR, SEE SCHEDULE 51 2" EXTERIOR INTERIOR WOOD CASING, TBD BY OWNER INTERIOR EXTERIOR 31 2" WINDOW/DOOR, SEE SCHEDULE WOOD SILL BELOW SILL BELOW P.T. SHIM W/ THERMAL INSULATION B/W SHIMS BACKER ROD AND SEALANT MOISTURE BARRIER EXTERIOR SHEATHING SIDING - REF. ELEVATIONS INTERIOR FINISH MATERIAL 1X CASING 2X STUD WALL @ 16" O.C. W/ THERMAL INSULATION 5/4X4 TRIM 2X SILL PLATE 2X6 STUD WALL @ 16" O.C. W/ THERMAL INSULATION INTERIOR FINISH MATERIAL BLOCKING EXTERIOR INTERIOR EXTERIOR SHEATHING 2X TRIM, CHAMFER BACKER ROD AND SEALANT 11 2" 2" WINDOW, SEE SCHEDULE EXTERIOR INTERIOR 1" 3 4" SIDING - REF. ELEVATIONS OPTIONAL SILL PAN, SEE MANUFACTURER'S SPECIFICATIONS SILL TRIM TBD BY OWNER INTERIOR EXTERIOR 4"INTERIOR WALL FINISH 1X CASING EXTENSION JAMB WOOD SILL BELOW EXTERIOR SHEATHING 2X STUD 5/4X6 TRIM RIPPED TO 4" SHIM W/ THERMAL INSULATION BETWEEN SHIMS CLAD WINDOW, SEE SCHEDULE SILL BELOW BACKER ROD & SEALANT 3" 6" INTERIOR FLOOR FINISH P.T. SHIM DOOR, SEE SCHEDULE 2X FLOOR FRAMING, SEE STRUCTURAL P.T. WOOD SILL 3" 13 4" 1 2" METAL PAN FLASHING W/ END DAMS SET IN CONT. BED OF SEALANT 2X FLOOR FRAMING, SEE STRUCTURAL WOOD DECKING SLOPE TO DRAIN 5/4X OVER BLOCKING 2X SILL PLATE 2X6 STUD WALL @ 16" O.C. W/ THERMAL INSULATION INTERIOR FINISH MATERIAL BLOCKING EXTERIOR INTERIOR EXTERIOR SHEATHING CHAMFER 2X6 TRIM, OVER BLOCKING BACKER ROD AND SEALANT 51 2" 2" WINDOW, SEE SCHEDULE EXTERIOR INTERIOR 1 2" 1 2" SIDING - REF. ELEVATIONS OPTIONAL SILL PAN, SEE MANUFACTURER'S SPECIFICATIONS SILL TRIM TBD BY OWNER 1 2 3 3" = 1'-0" WINDOW HEAD - TYP 3" = 1'-0" WINDOW SILL - TYP 3" = 1'-0" WINDOW JAMB - TYP 4 3" = 1'-0" WINDOW MULL - TYP A505 WIN. & DOOR DETAILS 5 3" = 1'-0" DOOR SILL - TYP NOTE: WINDOW / DOOR DETAILS BY WINDOSOR LEGEND SERIES. SEE INSTALLATION DIAGRAM AND MANUFACTURER'S INSTALLATION INSTRUCTIONS FOR FLASHING AND WATERPROOFING. © 2020 PEARCE SCOTT ARCHITECTS PEARCE SCOTT ARCHITECTS 6 STATE OF MIND ST SUITE 200 BLUFFTON, SC 29910 843.837.5700 NEW RESIDENCE FOR: KATE EAGEN LOT 45 STOCK FARM HISTORIC DISTRICT BLUFFTON, SC 29910 DESCRIPTION / REVISION LOGNO. INITIALDATE PROJECT NO. NO. DATE 12.08.20 DRAWN BY AJD CHECKED BY AWB SHEET NO. DO NOT SCALE FROM DRAWINGSNOT FOR CONSTRUCTION 24X36 PAPER SIZE HPC CONCEPTUAL SUBMITTAL AJD10.14.20 HPC FINAL SUBMITTAL AJD12.08.20 6 3" = 1'-0" 6" WINDOW SILL ATTACHMENT 4 A B C D 2'-8" 6'-0" 2'-8" 4'-6" 2'-8" 5'-0" NOTE: VERIFY ALL SIZES, DIMENSIONS AND ROUGH OPENING REQUIREMENTS WITH MANUFACTURER. 2'-8" 4'-0" 2 OVER 2 REMARKSDESCRIPTIONMANUF.MODEL NO.TYPE WINDOW HEAD SILL A DETAILS FRAME SIZE 2'-8" X 6'-0" JAMB MULL NOMINAL LITE CONFIG. CLAD DOUBLE HUNG 1/A505 2/A505 3/A505 2'-8" X 4'-6"B C* 2 OVER 2 D MARVIN ELEVATE 2'-8" X 4'-0" 2'-8" X 5'-0" 2 OVER 2 NOTES: 1. DESIGN BASED ON MARVIN ELEVATE WINDOWS. (CLASSIC DOUBLE-HUNG & SIGNATURE CASEMENT). ALL WINDOWS & DOORS TO HAVE SIMULATED DIVIDED LITES WITH SPACER BARS (SDLS). 2. ALL WINDOWS ARE TO BE IMPACT-RATED OR CONTRACTOR TO INSTALL PERMANENT FASTENERS FOR HURRICANE PROTECTION AS REQUIRED BY CODE. 3. REFER TO MANUFACTURER'S SPECIFICATIONS FOR VARIOUS EXTERIOR WINDOW ROUGH OPENING REQUIREMENTS. 4. *VERIFY THAT SELECT WINDOWS MEET NATIONAL EGRESS CODES FOR FIRE EVACUATION. SILL TO BE MAX. 44" A.F.F. FOR EGRESS 5. ALL WINDOWS TO BE OPERABLE UNLESS OTHERWISE NOTED. 6. IF MANUFACTURER CHANGES, COORDINATE WITH ARCHITECT AS IT MAY HAVE AN IMPACT ON DESIGN. 7. IF WINDOWS ARE GROUPED, MAINTAIN MULL AS PER DETAIL. CLAD DOUBLE HUNG CLAD CASEMENT CLAD CASEMENT 2 OVER 2 4/A505 1/A505 2/A505 3/A505 4/A505 1/A505 6 OR 2/A505 3/A505 4/A505 1/A505 3/A505 4/A505 6/A505 IN C.H. 2/A505 IN MAIN HOUSE MARVIN ELEVATE MARVIN ELEVATE MARVIN ELEVATE 6/A505 NOTES: 1. REFER TO MANUFACTURER'S SPECIFICATIONS FOR VARIOUS INTERIOR AND EXTERIOR DOOR ROUGH OPENING REQUIREMENTS. 2. PROVIDE TEMPERED GLAZING AS REQUIRED BY CODE. SEE DOOR ELEVATIONS FOR LOCATIONS OF TEMPERED GLAZING IN DOORS. 3. POCKET DOORS TO HAVE FOUR WHEEL HEAVY DUTY TRACK ASSEMBLY BY JOHNSON HARDWARE. 4. DOOR STYLE TO BE SELECTED BY OWNER/CONTRACTOR. REMARKSDESCRIPTIONTYPEROOM NAMEDOOR HEAD DETAILS JAMBSILLDOOR SIZE NOMINAL 1/A505 SIM. 3/A505 SIM.001A 001C 002A 002B 002C 003A GARAGE 9'-0" X 8'-0"OVERHEAD GARAGE DOOR MATERIAL FIR OR SIM. 5/A505 SIM. 003B 101A H 6 LITE, 2 PANEL 001B GARAGE GARAGE STUDIO 9'-0" X 8'-0"OVERHEAD GARAGE DOORH 3'-0" X 8'-0"EXTERIOR OUTSWING DOORG 4 LITE, 1 PANEL (1/2 LITE) 3/A505 SIM. 3/A505 SIM. 6 LITE, 2 PANE STUDIO STUDIO STUDIO BATH STUDIO BATH 101B 101C 101D 103A 103B 103C 104A 105A 106A 107A 107B 109A 109B 200A 201A 201B 202A 202B 203A 203B GREAT ROOM GREAT ROOM GREAT ROOM GREAT ROOM MUDROOM/LAUNDRY MUDROOM/LAUNDRY MUDROOM/LAUNDRY POWDER OWNER'S BEDROOM OWNER'S WIC OWNER'S BATH OWNER'S BATH SCREENED PORCH SCREENED PORCH STAIR HALL BATH 2 BEDROOM 2 BATH 2 BEDROOM 2 BEDROOM 3 BEDROOM 3 EXTERIOR INSWING ENTRY DOOR PAIR INTERIOR DOOR INTERIOR DOOR INTERIOR POCKET DOOR INTERIOR POCKET DOOR PAIR EXTERIOR OUTSWING DOOR (2) 3'-0" X 8'-0" 1/A505 SIM. 5/A505 3/A505 SIM. 6 LITE FIR OR SIM.3'-0" X 7'-0" 1/A505 SIM. 5/A505 SIM. (4" STEP) 3/A505 SIM.J MDF MDF MDF MDF (2) 2'-0" X 7'-0" 2'-8" X 7'-0" PAIR EXTERIOR OUTSWING DOOR PAIR EXTERIOR OUTSWING DOOR PAIR EXTERIOR OUTSWING DOOR (2) 3'-0" X 8'-0" (2) 3'-0" X 8'-0" (2) 3'-0" X 8'-0" 1/A505 SIM. 3/A505 SIM. 6 LITE 1/A505 SIM. 3/A505 SIM. 6 LITE 1/A505 SIM. 3/A505 SIM. 6 LITE 2'-4" X 7'-0" 2'-4" X 7'-0" EXTERIOR INSWING DOORG 3'-0" X 8'-0" 1/A505 SIM. 3/A505 SIM. F K M L L MDFINTERIOR POCKET DOORD 3'-0" X 8'-0" MDFINTERIOR POCKET DOORD 3'-0" X 8'-0" MDFINTERIOR DOORD 3'-0" X 8'-0" MDFINTERIOR DOORD 3'-0" X 8'-0" INTERIOR DOOR MDF2'-4" X 8'-0"B INTERIOR DOOR MDF2'-4" X 8'-0"B INTERIOR POCKET DOOR MDF2'-4" X 8'-0"B EXTERIOR SCREENED DOOR SCREENED DOOR1/A505 SIM.3'-0" X 7'-0"E 3/A505 SIM.FIR OR SIM. EXTERIOR SCREENED DOOR SCREENED DOOR1/A505 SIM.3'-0" X 7'-0"E 3/A505 SIM. B INTERIOR DOOR MDF2'-4" X 8'-0" B INTERIOR DOOR MDF2'-4" X 8'-0" B INTERIOR DOOR MDF2'-4" X 8'-0" C INTERIOR DOOR MDF2'-8" X 8'-0" B INTERIOR DOOR MDF2'-4" X 8'-0" C INTERIOR DOOR MDF2'-8" X 8'-0" B INTERIOR DOOR MDF2'-4" X 8'-0" 1/A505 SIM. 1/A505 SIM.COMPOSITE COMPOSITE 5/A505 5/A505 5/A505 5/A505 POCKET POCKET POCKET POCKET POCKET F F F FIR OR SIM. FIR OR SIM. FIR OR SIM. FIR OR SIM. FIR OR SIM. FIR OR SIM. 4 LITE, 1 PANEL (1/2 LITE) 4 LITE, 1 PANEL (1/2 LITE) A C 8'-0" 3'-0" FB 2'-4" 8'-0" 8'-0" D 8'-0" 2'-8" 3'-0" 7'-0" 3'-0" E 512" 512" 512"8" T = TEMPERED T G 3'-0" T 3'-0" 8'-0" 9'-0" 8'-0" H J 3'-0" T 3'-0" 7'-0" K ML 2'-4" 7'-0" 7'-0" 2'-8"2'-0" 7'-0" NOT USED 1 2 3 4 STEP STEP STEP STEP MOISTURE BARRIER MOISTURE BARRIER PEELED UP WITH 45 DEGREE SEAMS AT OPENING S.A.F. OVER MOISTURE BARRIER UNDER NAILING FLANGE (LEAVING FLANGE EXPOSED) WRAP MOISTURE BARRIER OVER TOP NAILING METAL FLASHING S.A.F. OVER SEAMS OF MOISTURE BARRIER AT TOP FLANGE S.A.F. OVER NAILING FLANGES AT JAMBS, LAP OVER S.A.F. AT SILL S.A.F. OVER MOISTURE BARRIER AT JAMBS OPTIONAL SILL PAN W/ END DAMS, SET IN CONTINUOUS BEAD OF SEALANT, SEE WINDOW MANUFACTURER RECOMMENDATIONS NOTE: DETAILS SIMILAR @ DOOR HEAD AND JAMBS CONTINUOUS BEAD OF SEALANT BEHIND FLANGE AT HEAD AND JAMBS S.A.F. OVER NAILING FLANGE AT HEAD, LAP OVER S.A.F. AT JAMBS METAL FLASHING OVER S.A.F., SEALED AT TOP W/ ADD. PIECE OF S.A.F. A601 WIN. & DOOR SCHEDULE 1/4" = 1'-0" WINDOW ELEVATIONS 2 4 NTS DOOR SCHEDULE 5 NTS WINDOW SCHEDULE 1/4" = 1'-0" DOOR ELEVATIONS 1 1/4" = 1'-0" INSTALLATION DIAGRAM 3 © 2020 PEARCE SCOTT ARCHITECTS PEARCE SCOTT ARCHITECTS 6 STATE OF MIND ST SUITE 200 BLUFFTON, SC 29910 843.837.5700 NEW RESIDENCE FOR: KATE EAGEN LOT 45 STOCK FARM HISTORIC DISTRICT BLUFFTON, SC 29910 DESCRIPTION / REVISION LOGNO. INITIALDATE PROJECT NO. NO. DATE 12.08.20 DRAWN BY AJD CHECKED BY AWB SHEET NO. DO NOT SCALE FROM DRAWINGSNOT FOR CONSTRUCTION 24X36 PAPER SIZE HPC CONCEPTUAL SUBMITTAL AJD10.14.20 HPC FINAL SUBMITTAL AJD12.08.20 ATTACHMENT 4 DUPLEX OUTLET GROUND FAULT CIRCUIT INTERUPTER WEATHER-PROOF OUTLET SWITCHED OUTLET 220 V. OUTLET FLOOR OUTLET CABLE T.V. JACK TELEPHONE JACK SURFACE MOUNTED CEILING FIXTURE CHANDELIER WALL FIXTURE EXHAUST FAN SWITCH THREE-WAY SWITCH FOUR-WAY SWITCH FAN SWITCH CEILING FAN RECESSED FIXTURE GARBAGE DISPOSAL PENDANT DIMMER SWITCH ELECTRICAL LEGEND DATA WALL WASHER GENERAL ELECTRICAL PLAN NOTES: 1. COORDINATE W/ OWNER ELECTRICAL ROUGH-IN LOCATIONS PRIOR TO START OF ELECTRICAL WORK. 2. INSTALL SMOKE DETECTORS IN ACCORDANCE WITH SECTION R313 (SMOKE ALARMS) OF THE INTERNATIONAL RESIDENTIAL CODE. 3. COORDINATE THERMOSTAT LOCATIONS W/ OWNER AND PER FINAL HVAC RETURN GRILLE LOCATIONS. 4. COORDINATE LANDSCAPE LIGHTS AND GAS LAMP POST LOCATIONS W/ LANDSCAPE ARCHITECT. 5. COORDINATE METER SIZE WITH CONTRACTOR WATER PROOF RECESSED FIXTURE SLOPED RECESSED FIXTURE UNDER COUNTER LIGHT GAS LIGHT SMOKE DETECTOR FLOURESCENT LIGHT GARAGE DOOR OPENER JUNCTION BOX METER - SIZE TBD BY CONTRACTOR J K-3429 MEMOIRS TOILETS VITREOUS CHINA K-3429 MEMOIRS TOILETS VITREOUS CHINA K-710 IRON WORKS BATH KOHLER CAST IRON CL CL CL CL CL CLCL CL CL CLCL CL CL CL CL CL CL CL CL CL CL CL CL CL CL CL CL CL CL CL CL EQ.EQ. CL EQ. EQ. CL TO LIGHTS & SWITCH ABOVE J CL EQ. EQ. CL CL D/W REF D W STEP LIGHTS JAMB SWITCH TO LIGHTS ON C.H. TO SWITCH @ GARAGE FIRST FLOOR ELEC. PLAN 1/4" = 1'-0" FIRST FLOOR ELECTRICAL PLAN 1 E101 © 2020 PEARCE SCOTT ARCHITECTS PEARCE SCOTT ARCHITECTS 6 STATE OF MIND ST SUITE 200 BLUFFTON, SC 29910 843.837.5700 NEW RESIDENCE FOR: KATE EAGEN LOT 45 STOCK FARM HISTORIC DISTRICT BLUFFTON, SC 29910 DESCRIPTION / REVISION LOGNO. INITIALDATE PROJECT NO. NO. DATE 12.08.20 DRAWN BY AJD CHECKED BY AWB SHEET NO. DO NOT SCALE FROM DRAWINGSNOT FOR CONSTRUCTION 24X36 PAPER SIZE HPC CONCEPTUAL SUBMITTAL AJD10.14.20 HPC FINAL SUBMITTAL AJD12.08.20 SEE SHEET A104 ATTACHMENT 4 DUPLEX OUTLET GROUND FAULT CIRCUIT INTERUPTER WEATHER-PROOF OUTLET SWITCHED OUTLET 220 V. OUTLET FLOOR OUTLET CABLE T.V. JACK TELEPHONE JACK SURFACE MOUNTED CEILING FIXTURE CHANDELIER WALL FIXTURE EXHAUST FAN SWITCH THREE-WAY SWITCH FOUR-WAY SWITCH FAN SWITCH CEILING FAN RECESSED FIXTURE GARBAGE DISPOSAL PENDANT DIMMER SWITCH ELECTRICAL LEGEND DATA WALL WASHER GENERAL ELECTRICAL PLAN NOTES: 1. COORDINATE W/ OWNER ELECTRICAL ROUGH-IN LOCATIONS PRIOR TO START OF ELECTRICAL WORK. 2. INSTALL SMOKE DETECTORS IN ACCORDANCE WITH SECTION R313 (SMOKE ALARMS) OF THE INTERNATIONAL RESIDENTIAL CODE. 3. COORDINATE THERMOSTAT LOCATIONS W/ OWNER AND PER FINAL HVAC RETURN GRILLE LOCATIONS. 4. COORDINATE LANDSCAPE LIGHTS AND GAS LAMP POST LOCATIONS W/ LANDSCAPE ARCHITECT. 5. COORDINATE METER SIZE WITH CONTRACTOR WATER PROOF RECESSED FIXTURE SLOPED RECESSED FIXTURE UNDER COUNTER LIGHT GAS LIGHT SMOKE DETECTOR FLOURESCENT LIGHT GARAGE DOOR OPENER JUNCTION BOX METER - SIZE TBD BY CONTRACTOR J K-3429 MEMOIRS TOILETS VITREOUS CHINA KING CL CL CL CL CL CLCL CLCL STEP LIGHTS REF W/D CL CL CL EQ. EQ. EQ. EQ. EQ. CL J TO SWITCH @ MAIN HOUSE TO SWITCH @ MAIN HOUSE K-1123 ARCHER BATHING ACRYLIC K-3429 MEMOIRS TOILETS VITREOUS CHINA CL CL CL CLCLCL CL CL CL CL CL CL CL CL TO SWITCH BELOW SCND FLOOR ELEC. PLAN 1/4" = 1'-0" SECOND FLOOR ELECTRICAL PLAN 1 E102 © 2020 PEARCE SCOTT ARCHITECTS PEARCE SCOTT ARCHITECTS 6 STATE OF MIND ST SUITE 200 BLUFFTON, SC 29910 843.837.5700 NEW RESIDENCE FOR: KATE EAGEN LOT 45 STOCK FARM HISTORIC DISTRICT BLUFFTON, SC 29910 DESCRIPTION / REVISION LOGNO. INITIALDATE PROJECT NO. NO. DATE 12.08.20 DRAWN BY AJD CHECKED BY AWB SHEET NO. DO NOT SCALE FROM DRAWINGSNOT FOR CONSTRUCTION 24X36 PAPER SIZE HPC CONCEPTUAL SUBMITTAL AJD10.14.20 HPC FINAL SUBMITTAL AJD12.08.20 1/4" = 1'-0" SECOND FLOOR ELECTRICAL PLAN 11/4" = 1'-0" SECOND FLOOR ELECTRICAL PLAN 1 ATTACHMENT 4 PLANTING PLAN L1 SUBMITTAL PLAN, NOT FOR CONSTRUCTION DRAWING NUMBER DRAWING TITLE DESIGN CONCEPTS, DRAWING, SHEETS, LOGOS, SPECIFICATIONS, DETAILS, WRITTEN MATERIAL SHALL NOT BE USED OR REPRODUCED IN WHOLE OR IN PART IN ANY FORM WITHOUT PRIOR WRITTEN CONSENT OF WJK LTD. © 2020 WJK LTD. THIS SHEET TO SCALE AT: 24"X36" DATE: PROJECT NO.: DRAWN BY: CHECKED BY: DEC. 09, 2020 XXXXX.XX JM DK REVISIONS: SITE DEVELOPMENT PLANS FOR EAGEN RESIDENCE STOCK FARM / BLUFFTON, SOUTH CAROLINA GUILFORD PLACE / LOT 45 PLANTING REFERENCE NOTES: 1EXISTING TREES TO REMAIN. EXISTING TREES TO BE REMOVED. MULCH DISTURBED AREAS DUE TO CONSTRUCTION. PROTECT AREA DRAIN FROM CLOGGING DURING INSTALLATION OF PLANTS AND MULCH. MAINTAIN FUNCTIONALITY AND POSITIVE PITCH TO DRAIN. PRUNE TREE LIMBS CONFLICTING WITH HOUSE FRAMING. 2 4 3 5 010203040 5152535 Scale 1 " = 10' c N E W RESIDENCE CARRIAGE HOUSE GUILFORD PLACE PROPERTY LINE 10' B.S.L. 10' B.S.L. PROPERTY LINE PROPERTY LINE 25' B.S.L. PROPERTY LINE 10' B.S.L. 1 LAGN 7 SPAB 5 ILLF 10 SPAB 1 HYDP 3 ILLF 1 HYDP 5 PODM HERB GARDEN, BY OWNER 3 ILVN 5 PERE 10 PERE 1 QUEV 1 OSMF 2 SABP 5 PODM 1 OSMF 1 PHIS 10 PLUA 10 PODP 1 CAMS 10 PERE 5 THEK 5 ALPZ 1 CAMS 5 THEK 3TYP. 1TYP. 2TYP. 4TYP. 5TYP. PAVING SCHEDULE SYMB.DESCRIPTION 2.1 CALL- OUT 2.2 2.3 OYSTER SHELL WALK TABBY CONCRETE APRON 2.4BRICK WALK / LANDING / PATIO SPRING MIX GRAVEL DRIVE NABRICK BORDERS NOTE: MATERIAL SYMBOLS / HATCHES ARE GRAPHIC IN NATURE AND ARE NOT INTENDED TO BE TO SCALE. REFER TO SITE DETAILS AND LAYOUT PLANS FOR SIZES AND DIMENSIONS. SITE DETAILS LEGEND DESCRIPTION 9.1 CALL- OUT 7.1LIVING FENCE FIRE PIT 7.2GATE 2.3 2.1 2.4 2.2 9.1 7.2 7.1 SOD SOD SOD SOD SOD PLANT SCHEDULE: TREE CANOPY COVERAGE: CANOPY COVERAGE SUMMARY COVERAGE (SF) DESCRIPTION SITE AREA BUILDING FOOTPRINT REMAINING SITE AREA MATURE CANOPY COVERAGE PROVIDED (EXISTING AND PROPOSED) 10,952 3,128 7,824 5,839 % CANOPY COVERAGE (75% MIN.)75% CANOPY COVERAGE OF EXISTING AND PROPOSED TREES (GREEN SHADED AREA) 1 SABP (OPTIONAL) 5 ILVN 5 ILVN ATTACHMENT 5 PLAN REVIEW COMMENTS FOR COFA-10-20-014673 Town of Bluffton Department of Growth Management 20 Bridge Street P.O. Box 386 Bluffton, South Carolina 29910 Telephone 843-706-4522 OLD TOWN Plan Type: Apply Date: Plan Status: Plan Address: 5718 Guilford Pl Place BLUFFTON, SC 29910 Historic District Active 10/15/2020 Plan PIN #:Case Manager: R610 039 00A 0396 0000Katie Peterson Plan Description: A request by Pearce Scott Architects, on behalf of owner, Kate Eagen, for review of a Certificate of Appropriateness Application to allow for the construction of a new single-family residential structure of approximately 2,117 SF and a Carriage House of approximately 1,172 SF located at 5718 Guilford Place, identified as Lot 45 in the Stock Farm Development, in the Old Town Bluffton Historic District and zoned Neighborhood General – HD. STATUS 10-27-2020: The application is currently being reviewed by Staff for conformance with the Unified Development Ordinance (UDO), Traditional Construction Patterns, and any development plans associated with the parcel and is scheduled for review by the HPRC at the November 2, 2020 meeting. Staff Review (HD) Submission #: 1 Recieved: 10/15/2020 Completed: 10/30/2020 Reviewing Dept. Complete Date StatusReviewer Approved with Conditions10/30/2020Building Safety Review Richard Spruce Comments: 15 Oct 2020 - RAS Guardrails may be required for all porches. The porches show an elevation of 30-inches in these drawings. The International Residential Code (IRC), 2018 Edition, section 312.1.1 states that guardrails are required where the walking surfaces are over 30-inches above grade measured 36-inches out from the open edge of the walking surface. Insect screening shall not be considered as a guard. So it depends on final grade before we can tell if the guardrails will be required. Of course there is another section that states grading shall be away from the foundation at 6-inches in the first 10-feet (IRC 401.3). With this being said it appears that 3 feet away from the porch the drop will exceed 30-inches, therefore guardrails will be required. Approved with Conditions10/30/2020Growth Management Dept Review (HD) Katie Peterson Comments: 1. For the Final submittal, a letter of approval from the Stock Farm HARC is required. (Applications Manual) 2. In keeping with masonry building technology, metal spark arrestors, exposed metal flies, or pre-fabricated chimney capos are not permitted. The proposed chimney shows a metal chimney cap. Revise the chimney cap to a permitted material or provide additional information for HPC review and determination on the appropriateness of a material not specifically listed in the UDO. (UDO Section 5.15.6.E.8.d.) 3. The UDO requires that porch posts shall be spaced no farther apart than they are tall. Columns are proposed as further apart on center than they are tall at the corner bay (11'1") on the front elevation and the side porch (10'6"). The porch post placement must be revised to meet this requirement. (UDO Section 5.15.6.H.1.a. and Traditional Construction Patterns Section 52) 4. Metal roofs are permitted to have a 5-V or Standing Seam profile. The plans and application note the roof to be metal, but do not specify what profile will be used. Provide additional information on the metal roof profile. 5.For the final application provide a landscape plan noting foundation plantings, street tree locations, canopy coverage, and any landscaping proposed for buffering; as well provide architectural details of the railing and baluster, a typical window detail, corner board/pilaster trim detail, water table detail, screen porch detail, and sections through the eave and wall depicting the material configuration and dimensions. (Applications Manual) 6. A tree removal permit is required for the removal of any tree on a single-family residential lot that measures 14" in DBH or greater. A few of the trees on the site proposed for removal exceed 14" in DBH. As such, a tree removal permit is required. Approved with Conditions10/30/2020Watershed Management Review William Baugher Comments: 10/30/2020 Page 1 of 2 ATTACHMENT 6 1. Small Construction Activities, The Town will require a Stormwater Affidavit with a SC DHEC NOI form D-0451 and implementation of the Construction Site BMPs found in Chapter 9 of the Stormwater Design Manual and the SCDHEC Erosion and Sediment Reduction standards and other Stormwater Management regulations, where applicable before Building Permits will be issued. Approved10/30/2020Beaufort Jasper Water and Sewer Review James Clardy Approved10/30/2020HPRC Review Katie Peterson Comments: 1. Thank you for providing well dimensioned and wholly visible plans with your submittal. Approved10/30/2020Transportation Department Review - HD William Howard Approved10/22/2020Addressing Review Nick Walton Comments: 1. No comment. Plan Review Case Notes: 10/30/2020 Page 2 of 2 ATTACHMENT 6 STOCK FARM DEVELOPMENT BOX 2570 BLUFFTON, SC 29910 15 December 2020 To: Katie Peterson, Town of Bluffton Subject: HPC Review of Stock Farm Applications Katie—It is understood that the HPC, in January, will review plans from two applicants and Stock Farm property owners: -----Romski-5806 Guilford Place (Lot 20A)—Carriage House Additions -----Eagen-5718 Guilford Place (Lot 45)—Personal Residence Stock Farm has reviewed the plans and found these to meet the community requirements. It is recommended that these plans be granted a Certificate of Appropriateness. Emmett McCracken Manager ATTACHMENT 7 20 Meriwether Court, Lot 3 – Certificate of Appropriateness Historic Preservation Commission HISTORIC PRESERVATION COMMISSION STAFF REPORT Department of Growth Management MEETING DATE: January 6, 2021 PROJECT: Lot 3, 20 Meriwether Court – New Construction: Single-Family Residential APPLICANT: Webb Construction PROJECT MANAGER: Katie Peterson, AICP, Senior Planner APPLICATION REQUEST: The Applicant, Webb Construction, on behalf of Ernie Suozzi, requests that the Historic Preservation Commission approve the following application: 1. COFA-10-20-014694. A Certificate of Appropriateness to allow the construction of a 1.5-story single-family residential structure of approximately 1,954 SF and a 1-story Carriage House of approximately 352 SF located at 20 Meriwether Court, Lot 3 in the Landen Oaks Development in the Old Town Bluffton Historic District, and zoned Neighborhood General-HD. INTRODUCTION: The Applicant is proposing the construction of a detached single- family residence located in the Old Town Bluffton Historic District. The proposed building, of approximately 1,954 SF, has similar attributes of the Village House, but is not 2 stories in height, so it is reviewed as an Additional Building Type in accordance with the allowable building types for the Neighborhood General-HD zoning district. In addition to the primary structure, the Applicant is proposing a Carriage House structure of approximately 352 SF, which meets the design standards for a Carriage House Building Type. This lot is located within the Landen Oaks development plan, which was approved in April of 2019 (COFA-07-15- 009290), which specifies that the setbacks must meet those found in the Unified Development Ordinance. The main house structure is under a two-story forward-facing gable with side-facing gable projection to the left. It features a front porch under a hip roof and a small rear porch under the same. The second story porch on the rear elevation has a trellis detail rather than a roof. The proposed materials include combination of horizontal lap siding on most of the house with vertical board and batten in the gabled ends. The gable ends also unique trim detailing and a round window. It has a 5V metal roof. The Carriage House features similar materials and trim detailing as the primary structure. It is one-story in height and has a forward facing gable roof. January 6, 2021 Page 2 20 Meriwether Court, Lot 3 – Certificate of Appropriateness Historic Preservation Commission This project was presented to the Historic Preservation Review Committee for conceptual review at the November 16, 2020 meeting and comments were provided to the Applicant (See attachment 5). HISTORIC PRESERVATION COMMISSION ACTIONS: As granted by the powers and duties set forth in Section 2.2.6.E.2, the Historic Preservation Commission has the authority to take the following actions with respect to this application: 1. Approve the application as submitted by the Applicant; 2. Approve the application with conditions; or 3. Deny the application as submitted by the Applicant. It is important to note that the intent of Section 5.15 Old Town Bluffton Historic District of the Unified Development Ordinance (UDO) is that the Section be user friendly and informative to the residents and the members of HPC and is not intended to discourage creativity or force the replication of historic models. Rather, it is to set forth a framework in which the diversity that has always characterized Bluffton can continue to grow. The Section also defines guidelines for design and materials similar to that used on structures within the Old Town, and it is the charge of the HPC to assess the interpretation of these guidelines as they pertain to applications using the established review criteria. REVIEW CRITERIA & ANALYSIS: Town Staff and the Historic Preservation Commission are required to consider the criteria set forth in Section 3.18.3 of the UDO in assessing an application for a Certificate of Appropriateness – Historic District (HD). The applicable criteria are provided below followed by a Staff Finding(s) based upon review of the application submittals to date. 1. Section 3.18.3.B. Consistency with the principles set forth in the Old Town Master Plan. a. Finding. The application is consistent with the principles set forth in the Old Town Master Plan. The Old Town Master Plan states that, “The built environment, in particular the historic structures scattered throughout Old Town, should be protected and enhanced. While it is of great importance to save and restore historic structures, it is just as important to add to the built environment in a way that makes Old Town more complete.” The Applicant proposes to construct a new single-family residence and Carriage House within the Old Town Bluffton Historic District, a locally and nationally designated historic district. The buildings have been designed to be sympathetic to the architectural character of the neighboring historic structures, so their addition to the architectural diorama will both protect the integrity of the existing historic structures and enhance the neighborhood by adding architectural variety. b. Finding. The Old Town Master Plan initiatives also include the adoption of a form-based code that included architectural standards for structures located within the Old Town Bluffton Historic District. These standards are included in Article 5 of the UDO. The new construction proposed as January 6, 2021 Page 3 20 Meriwether Court, Lot 3 – Certificate of Appropriateness Historic Preservation Commission part of this request will be in conformance with those standards if the conditions noted in item 2 of this Section are met. c. Finding. The Old Town Master Plan initiatives also promote preservation and protection of the legacy of the Old Town Bluffton Historic District through additions to the built environment which make Old Town more complete. The addition of the proposed residential structure and Carriage House add to the district as well as help provide completeness to the neighborhood and overall district. 2. Section 3.18.3.C. The application must be in conformance with applicable provisions provided in Article 5, Design Standards. a. Finding. Town Staff finds that the design of the primary structure falls within the category of Additional Building Type as allowed in the Neighborhood General Historic District per Section 5.15.5.C. Additional Building Types are permissible. As has been past practice, the Town Staff requests the Historic Preservation Commission review and make a final recommendation regarding the appropriateness of the Additional Building Type. b. Finding. Town Staff finds that if the conditions noted below are met, the proposed addition will be in conformance with applicable provisions provided in Article 5: 1) Section 5.15.6.A&I. Windows and Doors. Windows shall be square or rectangle. The plans show a decorative round window in the gable on the front and rear elevation. Per Section 5.15.6.A. of the UDO, the UDO Administrator, or in this case the HPC as the approval authority for a COFA, has the authority to allow substitute materials for those listed in the UDO, when it is appropriate. The applicant is requesting a determination on the appropriateness of the use of a round window as a substitute for those listed in Section 5.15.6.I of the UDO. 2) Section 5.15.6.H. Columns. Columns shall be spaced no further apart than they are tall. The columns on the second-story porch, at the back of the house on the left elevation are approximately 11’ apart and 8 feet tall. An additional column must be added or the columns reconfigured to be spaced no farther apart than they are tall in this location. 3) Section 5.15.5.C. Neighborhood General -HD Permitted Building Types. This structure has been designed as an Additional Building Type and meets the setbacks for an additional building type. It has all of the characteristics of a Village House, but the square footage listed falls within the half story definition. There appears to be a significant amount of space in the ‘Attic’ which should be January 6, 2021 Page 4 20 Meriwether Court, Lot 3 – Certificate of Appropriateness Historic Preservation Commission included in the square footage calculations as it meets has the required head height as defined in Article 9 of the UDO. A half- story is defined as a space under a sloping roof that has the line of intersection of the roof and the exterior wall supporting the roof not more than 3 feet above the floor level, and in which space the possible floor area with head room of 5 feet or more occupies between 30 and 70 percent of the total floor area of the story directly beneath. Additional information regarding the possible floor area with head room of 5 feet or more must be provided for review. Should the revised square-footage calculations exceed 70 percent of the story beneath it, the structure would be identified as a Village House and the setbacks would need to be revised to have a 10’-15’ front build-to, 15’ side setbacks and a 30’ rear setback. Alternately, the roof line may be lowered to reduce the amount of space with the possible floor area with head room of 5 feet or more to be within the 30 to 70 percent area of the floor beneath. 4) 3. Section 3.18.3.D. Consistency with the nature and character of the surrounding area and consistency of the structure with the scale, form and building proportions of the surrounding neighborhood. Finding. Town Staff finds the nature and character of the new construction to be consistent and harmonious with that of the surrounding neighborhood. The mass and scale of the structure is appropriate for its location and the architectural detailing is sensitive to the neighboring properties. 4. Section 3.18.3.F. The historic, architectural, and aesthetic features of the structure including the extent to which its alteration or removal would be detrimental to the public interest. Finding. The Applicant seeks approval for the construction of new structures in the Old Town Bluffton Historic District. The proposed plans are sympathetic in design to the neighboring historic and non-historic resources; therefore, the structure, as proposed, will have no adverse effect on the public interest. 5. Section 3.18.3.H. The application must comply with applicable requirements in the Applications Manual. Finding. The application has been reviewed by Town Staff and has been determined to be complete. STAFF RECOMMENDATION: It is the charge of the HPC to assess and interpret the standards and guidelines set forth in the UDO as they pertain to applications using the review criteria established in the UDO and to take appropriate action as granted January 6, 2021 Page 5 20 Meriwether Court, Lot 3 – Certificate of Appropriateness Historic Preservation Commission by the powers and duties set forth in Section 2.2.6.E.2. Town Staff finds that with the conditions noted below, the requirements of Section 3.18.3 of the Unified Development Ordinance have been met and recommends that the Historic Preservation Commission approve the application with the following conditions: 1. Per Section 5.15.6.A. and 5.15.6.I. The applicant is requesting a determination on the appropriateness of the use of a round window as a substitute for those listed in the UDO. 2. Per Section 5.15.6.H. of the UDO, columns must be reconfigured to be spaced no farther apart than they are tall on the second-story porch, at the back of the house on the left elevation. 3. Per Section 5.15.5.C. The second-floor square footage must be updated, and additional information must be provided regarding the possible floor area with head room of 5 feet or more. 4. Per Section 5.15.5.C. If the square footage exceeds 70% of the floor beneath, the setbacks must be revised to meet the Village House setbacks. ATTACHMENTS: 1. Location Map 2. Zoning Map 3. Application & Applicant Narrative 4. Site Plan & Elevations 5. Landscape Plan 6. HPRC Report 7. HOA Approval Letter 8. Chimney Cap Detail 20 Meriwether Ct, Lot 3: Location Map 1 2 / 2 1 / 2 0 2 0 0 0 . 0 3 0 . 0 5 0 . 0 8 0 . 1 0 . 1 30 . 0 1 m i F ATTACHMENT 1 20 Meriwether Ct, Lot 3: Zoning Map 1 2 / 2 1 / 2 0 2 0 0 0 . 0 3 0 . 0 5 0 . 0 8 0 . 1 0 . 1 30 . 0 1 m i F O v e r r id e 1 P a r c e l P r o p e r t y L in e s ATTACHMENT 2 TOWN OF BLUFFTON Growth Management Customer Service Center CERTIFICATE OF APPROPRIATENESS- OLD TOWN BLUFFTON HISTORIC DISTRICT (HD) APPUCATION 20 Bridge Street Bluffton, SC 29910 (843)706-4522 www.townofbluffton.sc.gov applicationfeedback@townofbluffton.com Applicant Property Owner Name: Webb Construction/ Brian Webb Name: Ernie Suozzi Phone: 843-247-7883 Phone: 843-422-0564 Mailing Address: 365 Red Cedar St. Ste 404 Mailing Address: 6 Mossy Oaks Lane Bluffton, SC 29910 Hilton Head Is. SC 29926 E-mail: webbconstruction96@gmail.com E-mail: athsoccer1@gmail.com Town Business License# (if applicable): UC- 06-20-033549 Project Information (tax map info available at http://www.townofbluffton.us/gis/) Project Name: 20 Meriwether Court Project Location: Landen Oaks Development Zoning District: Neighborhood General - HD Conceptual: I Final: D I Amendment: D Application for: � New Construction Acreage: .1340 □ Renovation/Rehabilitation/ Addition Tax Map Number(s): □ Relocation or Demolition Project Description: New residential home with a detached garage Minimum Requirements for Submittal □ 1. Full sized copies and digital files of the Site Plan(s). One (1) set for Conceptual, two (2) sets for Final □ 2. Full sized copies and digital files of the Architectural Plan(s). One (1) set for Conceptual, two (2) sets for Final □ 3. Project Narrative describing reason for application and compliance with the criteria in Article 3 of the UDO. □ 5. All information required on the attached Application Checklist. □ 6. An Application Review Fee as determined by the Town of Bluffton Master Fee Schedule. Checks made payable to the Town of Bluffton. Note: A Pre-Application Meeting is required prior to Application submittal. Disclaimer: The Town of Bluffton assumes no legal or financial liability to the applicant or any third party whatsoever by approving the plans associated with this permit. I hereby acknowledge by my signature below that the foregoing application is complete and accurate and that I am the owner of the subject property. As applicable, I authorize 9'e subject property to be posted and inspected. Property Owner Signature: I? /'--vJ1-1 �- ) 1671 Date: I ) ( � I IA-/))� Applicant Signature: R""' - ·- Date: \ \ I 4 I �o,... ,. For Office Use Application Number: Date Received: Received By: Date Approved: Town of Bluffton Certificate of Appropriateness-Historic District Application Last Updated: 4/8/2014 v) ATTACHMENT 3 TOWN OF BLUFFTON CERTIFICATE OF APPROPRIATENESS - HISTORIC DISTRICT PROJECT ANALYSIS In accordance with the Town of Bluffton Unified Development Ordinance (UDO), the following information shall be included as part of a Certificate of Appropriateness application submitted for review by the Historic Preservation Commission (HPC) and the Historic Preservation Review Committee. The use of this checklist by Town Staff or the Applicant shall not constitute a waiver of any requirement contained in the UDO. 1. DESIGN REVIEW PHASE CONCEPTUAL REVIEW FINAL REVIEW I 2. SITE DATA Identification of Proposed Building Type (as defined in Article 5): Add i t io n al b uil d i n g typ e Building Main Structure Ancillary Ancillary 4. SITE COVERAGE I Rear: 25 Description (Main House, Garage, carriage House, etc.) Main House Garage Impervious Coverage Building Footprint(s) Impervious Drive, Walks & Paths Open/Covered Patios A.TOTAL IMPERVIOUS COVERAGE B.TOTAL SF OF LOT % COVERAGE OF LOT (A/B= %) 5. BUILDING MATERIALS Building Element Materials, Dimensions, and Operation Foundation Block Walls Hardie Roof Metal Chimney Stucco Trim 2x4 Water table 2 x ripped w/ 2x12 Corner board 2x6 Railings 2x4 p.t Balusters 2x2 Handrails 2x4 p.t Building Setbacks Front: 10 Rt. Side: 10 3. BUILDING DATA Lt. Side: 10 Existing Square Proposed Square Footage Footage 1954 352 Coverage (SF) 2306 0 270 2576 5837 44% Building Element Materials, Dimensions, and Operation Columns Wod Windows Vinyl Doors Wood Shutters N/A Skirting/Underpinning 5/4 p.t Cornice, Soffit, Frieze Hardie Gutters N/A Garage Doors Metal/ Aluminum N/A Green/Recycled Materials Last Updated: 4/8/2014 ATTACHMENT 3 ATTACHMENT 3 New Single-Family Residence – - Two story 1954 heated sqft - Detached garage - No Trusses - Block foundation - Hardie Siding ATTACHMENT 3 ATTACHMENT 4 ATTACHMENT 4 ATTACHMENT 4 ATTACHMENT 4 ATTACHMENT 4 ATTACHMENT 4 ATTACHMENT 4 ATTACHMENT 4 ATTACHMENT 4 ATTACHMENT 4 & Engineering, Inc. www.sci-engng.com Bus(843) 718-2525 Goose Creek, South Carolina 105 Central Ave 200-B Structural Engineering Fax (843) 718-2776 SOUTHERNCONSULTINGINC.ANDENGINEERING, Southern Consulting Suozzi Residence 20 Merriweather Court Bluffton, SC Oct 29, 2020 ATTACHMENT 4 & Engineering, Inc. www.sci-engng.com Bus(843) 718-2525 Goose Creek, South Carolina 105 Central Ave 200-B Structural Engineering Fax (843) 718-2776 SOUTHERNCONSULTINGINC.ANDENGINEERING, Southern Consulting Suozzi Residence 20 Merriweather Court Bluffton, SC Oct 29, 2020 ATTACHMENT 4 & Engineering, Inc. www.sci-engng.com Bus(843) 718-2525 Goose Creek, South Carolina 105 Central Ave 200-B Structural Engineering Fax (843) 718-2776 SOUTHERNCONSULTINGINC.ANDENGINEERING, Southern Consulting Suozzi Residence 20 Merriweather Court Bluffton, SC Oct 29, 2020 ATTACHMENT 4 ✱ ✱ ✱ ✱ ✱ ✱ ✱ ✱ ✱ ✱ PLANTING PLAN L1 SUBMITTAL PLAN NOT FOR CONSTRUCTION DRAWING NUMBER DRAWING TITLE DESIGN CONCEPTS, DRAWING, SHEETS, LOGOS, SPECIFICATIONS, DETAILS, WRITTEN MATERIAL SHALL NOT BE USED OR REPRODUCED IN WHOLE OR IN PART IN ANY FORM WITHOUT PRIOR WRITTEN CONSENT OF WJK LTD. © 2020 WJK LTD. THIS SHEET TO SCALE AT: 24"X36" DATE: PROJECT NO.: DRAWN BY: CHECKED BY: DEC. 1, 2020 200XX.01 CB DK REVISIONS: SITE DEVELOPMENT PLANS FOR SUOZZI RESIDENCE BLUFFTON, SOUTH CAROLINA 20 MARIWETHER COURT / LOT 3 PLANT SCHEDULE 08162432 4122028 Scale 1" = 8' c N E W LOT 45 STOCK FARM RD. OPEN SPACE & R/W LOT 4 PARCEL 225 PERE 2 SABP 3 TRAJ 3 ILLF 3 PODP 5 PODM SOD GRAVEL DRIVE TABBY LANDING 5 PODP 1 PHIS 3 PODP 1 LIVC 100 OPHJ 1 CERC 3 HYDM 5 AZAF 5 BUXM TABBY LANDING 3 MUHC 3 MUHC 1 HYDP 3 PODM 5 PODM 2 TRAJ TABBY APRON 1 CAMS 50 OPHJ 15 OPHJ 1 CAMS 1 CAMS 5 BUXM MULCH DISTURBED AREAS, TYP. EXISTING TREE TO REMAIN, TYP. TABBY STEPPING STONES TO BE COORDINATED WITH DOOR LOCATION SYRUP KETTLE FIRE PIT GRAVEL TABBY LANDING TABBY STEPPING STONES, TYP. 1 CAMJ 1 QUEV 1 OSMF TREE CANOPY COVERAGE CANOPY COVERAGE SUMMARY COVERAGE (SF) DESCRIPTION SITE AREA BUILDING FOOTPRINT REMAINING SITE AREA MATURE CANOPY COVERAGE PROVIDED (EXISTING AND PROPOSED) 5820 1942 3878 3130 % CANOPY COVERAGE (75% MIN.)81% CANOPY COVERAGE OF EXISTING AND PROPOSED TREES (GRAY SHADED AREA) ATTACHMENT 4 ✱ ✱ ✱ ✱ ✱ ✱ ✱ ✱ ✱ ✱ PLANTING PLAN L1 SUBMITTAL PLAN NOT FOR CONSTRUCTION DRAWING NUMBER DRAWING TITLE DESIGN CONCEPTS, DRAWING, SHEETS, LOGOS, SPECIFICATIONS, DETAILS, WRITTEN MATERIAL SHALL NOT BE USED OR REPRODUCED IN WHOLE OR IN PART IN ANY FORM WITHOUT PRIOR WRITTEN CONSENT OF WJK LTD. © 2020 WJK LTD. THIS SHEET TO SCALE AT: 24"X36" DATE: PROJECT NO.: DRAWN BY: CHECKED BY: DEC. 1, 2020 200XX.01 CB DK REVISIONS: SITE DEVELOPMENT PLANS FOR SUOZZI RESIDENCE BLUFFTON, SOUTH CAROLINA 20 MARIWETHER COURT / LOT 3 PLANT SCHEDULE 08162432 4122028 Scale 1" = 8' c N E W LOT 45 STOCK FARM RD. OPEN SPACE & R/W LOT 4 PARCEL 225 PERE 2 SABP 3 TRAJ 3 ILLF 3 PODP 5 PODM SOD GRAVEL DRIVE TABBY LANDING 5 PODP 1 PHIS 3 PODP 1 LIVC 100 OPHJ 1 CERC 3 HYDM 5 AZAF 5 BUXM TABBY LANDING 3 MUHC 3 MUHC 1 HYDP 3 PODM 5 PODM 2 TRAJ TABBY APRON 1 CAMS 50 OPHJ 15 OPHJ 1 CAMS 1 CAMS 5 BUXM MULCH DISTURBED AREAS, TYP. EXISTING TREE TO REMAIN, TYP. TABBY STEPPING STONES TO BE COORDINATED WITH DOOR LOCATION SYRUP KETTLE FIRE PIT GRAVEL TABBY LANDING TABBY STEPPING STONES, TYP. 1 CAMJ 1 QUEV 1 OSMF TREE CANOPY COVERAGE CANOPY COVERAGE SUMMARY COVERAGE (SF) DESCRIPTION SITE AREA BUILDING FOOTPRINT REMAINING SITE AREA MATURE CANOPY COVERAGE PROVIDED (EXISTING AND PROPOSED) 5820 1942 3878 3130 % CANOPY COVERAGE (75% MIN.)81% CANOPY COVERAGE OF EXISTING AND PROPOSED TREES (GRAY SHADED AREA) ATTACHMENT 5 PLAN REVIEW COMMENTS FOR COFA-10-20-014694 Town of Bluffton Department of Growth Management 20 Bridge Street P.O. Box 386 Bluffton, South Carolina 29910 Telephone 843-706-4522 OLD TOWN Plan Type: Apply Date: Plan Status: Plan Address: 20 Meriwether Ct Court BLUFFTON, SC 29910 Historic District Active 10/21/2020 Plan PIN #:Case Manager: R610 039 00A 0390 0000Katie Peterson Plan Description: A request by Brian Webb, on behalf of owner, Ernie Suozzi, for review of a Certificate of Appropriateness Application to allow the construction of a new 1 ½ story single family residence of approximately 1,955 SF and a Carriage House of approximately 352 SF to be located at 20 Meriweather Court, in the Landon Oaks development, in the Old Town Bluffton Historic District and zoned Neighborhood General – HD. STATUS [11-4-2020]: The application is currently being reviewed by Staff for conformance with the Unified Development Ordinance (UDO), Traditional Construction Patterns, and any development plans associated with the parcel and is scheduled for review by the HPRC at the November 16, 2020 meeting. Staff Review (HD) Submission #: 1 Recieved: 10/29/2020 Completed: 11/13/2020 Reviewing Dept. Complete Date StatusReviewer Approved with Conditions11/09/2020Building Safety Review Richard Spruce Comments: 9 Nov 20 - RAS The plans do not show the height of the porches. They only state equal with the finished first floor. Guardrails may be required depending on the height of the porches above grade that is within 36 inches of the walking surface of the porch. Approved with Conditions11/13/2020Growth Management Dept Review (HD) Katie Peterson Comments: 1. The application identifies the structure as a Village House building type. While it has characteristics of a Village House, it is 1.5 stories rather than 2 and would therefore be reviewed as an Additional Building type. (UDO 5.15.5.C.) 2. The site plan shows the structure located at 5' from the left side, 26.7' from the rear, and 17.9' from the front property line. As an Additional Building type, the required setbacks are: Front 10'-20', Side 10', Rear 25'. (UDO5.15.5.C.) 3. For final submittal, a letter of approval from the POA is required as it is located in the Landen Oaks development. (Applications Manual) 4. The elevations show an attached garage while the site plan shows a detached garage. As a detached garage, the elevations must be updated to show the rear elevation where the connection will not be as not enough information was provided to complete the review. 5. Additional information on the finished floor height and porch height must be provided for review. Finished First Floor height is required to be a minimum of 3' above average adjacent sidewalk grade. (UDO 5.15.5.F.) Porch height is required to be a minimum of 30" from adjacent grade. 6. The porch section detail and garage wall section show the use of plywood in the soffit. Rough sawn wood, plywood, and aluminum are not permitted as soffit materials. The soffit material must be revised to a permitted material. 7. In keeping with masonry building technology, metal spark arrestors, exposed metal flies, or pre-fabricated chimney capos are not permitted. The proposed chimney shows is unclear about the proposed chimney cap. Provide additional information regarding the chimney cap material and configuration. (UDO Section 5.15.6.E.8.d.) 8. At time of final submittal, provide a Landscape Plan showing foundation plantings, street trees and canopy coverage. (Applications Manual) 9. The UDO requires that porch posts shall be spaced no farther apart than they are tall. Columns are proposed as further apart on center than they are tall on the right side rear porch on the first and second story and the left side elevation on the second story. The porch post placement must be revised to meet this requirement. (UDO Section 5.15.6.H.1.a. and Traditional Construction Patterns Section 52) 10. The UDO states that driveways shall be a maximum of 10 feet wide in front of the principal plane of the buildings. The plans show a 12 foot wide drive. Reduce the drive width to no more than 10 feet in width. (UDO Section 5.157.H.2.) 11/13/2020 Page 1 of 2 ATTACHMENT 6 Approved11/10/2020Beaufort Jasper Water and Sewer Review James Clardy Comments: 1. No comment. Approved11/13/2020HPRC Review Katie Peterson Comments: 1. No comment. Approved11/13/2020Transportation Department Review - HD William Howard Comments: 1. No Comment. Approved11/12/2020Watershed Management Review William Baugher Comments: 1. No Comment. Approved11/05/2020Addressing Review Nick Walton Comments: 1. No Comment. Plan Review Case Notes: 11/13/2020 Page 2 of 2 ATTACHMENT 6 ATTACHMENT 7 ATTACHMENT 8

Source: Town of Bluffton website. First collected Oct 14, 2026.