Minutes
Town of Awendaw · Charleston County · Minutes
Open the original document More from Town of Awendaw
Text
Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.
APPROVED
TOWN OF AWENDAW
6971 Doar Road | P.O. Box 520 | Awendaw, SC 29429
843.928.3100 | www.townofawendawsc.org
townadministrator@townofawendawsc.org
Katharine Watkins | Town Administrator
Takeya White | Town Clerk
Chris Crolley | Mayor
Town Council
Paul Brown | Wendy Helms
Grace Gasper | Rodney Porcher
Kent Prause | John Timmons
Town Council Special Called Meeting DRAFT Minutes
July 15th, 2026
5:00 P.M.
1. Call to Order
The Awendaw Special Called Meeting was called to order by Mayor Chris Crolley on Wednesday,
July 15th, 2026, at 5:00 PM
2. Roll Call
Present: Mayor Chris Crolley, Councilman Rodney Porcher, Councilman Paul Brown,
Councilwoman Wendy Helms, Councilwoman Grace Gasper, Councilman Kent Prause and Town
Staff Town Administrator Katharine Watkins, Town Clerk Takeya White (virtual), and Town Attorney,
James I. Ward, III.
It was noted that Councilman John Timmons arrived at 5:48 pm.
3. Invocation
The invocation was delivered by Mayor Chris Crolley.
4. Pledge of Allegiance
The Pledge of Allegiance was recited by all.
5. Civility Pledge
Councilman Paul Brown read the Town of Awendaw Civility Pledge.
6. Approval of the July 15th Town Council Special Called Meeting Agenda
Motion: To approve the July 15th Town Council Special Called Agenda was posed by
Councilwoman Grace Gasper and seconded by Councilman Rodney Porcher.
Discussion: None
Vote: The motion passed unanimously.
7. Executive Session in accordance with S.C. Code Section 30-4-70(a)(1) concerning personnel
matters related to the utilities manager.
Motion: To enter Executive Session was made by Councilwoman Wendy Helms and seconded
by Councilman Kent Prause.
Discussion: None
Vote: The motion passed unanimously.
SETTLED 1696
Page 1 of 7
APPROVED
Council went into Executive Session at 5:03 pm.
Upon
return to public session, Town Administrator Katharine Watkins noted for the record that no
motions, actions, or votes were taken during Executive Session. She further noted that Council had
feedback and considerations regarding certain decisions made during the session.
Council came out of Executive Session at 5:37pm.
Motion: To come out of Executive Session was made Councilwoman Wendy Helms and
seconded by Councilman Rodney Porcher.
Discussion: None
Vote: The motion passed unanimously.
8. Discussion with Town Water Professionals- [Time S tamp: 38:11/3:04:30]
Mayor Crolley opened the water discussion by framing it as the single highest-priority operational
issue facing the Town of Awendaw. He introduced the panel of water professionals assembled for
the meeting: Ron Bycroft, consultant for the Town's water system; Mickey Seabrook, engineer and
designer of the water system; and Christopher Cross, General Manager of H.M. Northam, the firm
that has operated the system for approximately 16 years. A representative from the South Carolina
Rural Water Association, Brandon Abernathy, was also in attendance.
Current System Conditions
Mayor Crolley described the water system's most pressing problems: pervasive hydrogen sulfide
odor affecting town residents, declining water pressure, and concern about fire suppression
capability during a severe drought. He noted that irrigation restriction letters had been circulated to
residents, but compliance appeared minimal. He also indicated that between 280 and 400 new
residential connections were anticipated imminently, with further growth beyond that still
unquantified.
Engineering History and System Overview — Mickey Seabrook
Engineer Mickey Seabrook provided historical context, explaining that the water system was
conceived approximately 50 years ago and developed with funding from the USDA Farmers Home
Administration. The system was designed as a long, linear distribution network—not a looped
system—which has significant consequences for water quality and pressure management. The
existing infrastructure was sized and designed for conditions that bear little resemblance to current
and projected demand.
Mr. Seabrook outlined three primary treatment options for addressing the hydrogen sulfide
problem:
• Chemical oxidation — The application of an oxidizing agent such as hydrogen peroxide
or chlorine to neutralize hydrogen sulfide compounds. He noted the significant
chemical demand: approximately 8 to 10 parts of oxidant are required to eliminate 1
part of hydrogen sulfide.
• Aeration — The stripping of hydrogen sulfide gas into the atmosphere by exposing water
to air. He cautioned that the water's current pH of 8 to 8.5 is not favorable for effective
aeration, and that pH adjustment with an acid would be necessary to bring the gas into
a state where it can be effectively stripped.
Page 2 of 7
APPROVED
• Ozo
ne treatment — The generation of ozone on-site to oxidize sulfide compounds as a
pretreatment step prior to chlorination. Mr. Seabrook noted this approach has safety
considerations, as ozone is a hazardous gas if it escapes into the atmosphere, and that
regulatory requirements would apply.
When asked by Council to identify the preferred option, Mr. Seabrook stated his preference for
chemical oxidation as a first step, though he acknowledged that cost would be a determining factor
in any final decision.
Discussion also turned to the non-looped nature of the distribution system. Mr. Seabrook
confirmed that the linear "spur" design creates dead ends throughout the system, making it
difficult to maintain adequate chlorine residual and requiring frequent and costly flushing. He
indicated that opportunities exist to loop portions of the system by negotiating easements across
developing properties, including tracts adjacent to Highway 17, which would significantly improve
circulation and water quality throughout the network.
Operational Perspective — Christopher Cross, H.M. Northam
General Manager Christopher Cross provided an operational assessment of current conditions. He
reported that the system is currently moving approximately 250,000 gallons per day, compared to
roughly 100,000 gallons per day in prior years, with peaks approaching 300,000 to nearly 400,000
gallons per day during high-demand periods. This four-fold increase in flow has overwhelmed a
system designed 16 years ago.
Mr. Cross explained the root of the chlorine management problem: with only a single point of
chlorine injection serving a distribution system spanning approximately 16 miles, it is impossible to
maintain a safe and effective chlorine residual throughout the network without approaching or
exceeding regulatory limits for disinfection byproducts (DBPs)—carcinogenic compounds formed
when chlorine reacts with organic matter. He stated that the Town has never failed a DBP test, but
that maintaining compliance while also addressing odor complaints represents a direct
operational conflict: more chlorine reduces odor but risks DBP violations; less chlorine protects
against DBPs but leaves the sulfide smell unaddressed.
Mr. Cross emphasized that the 200,000-gallon ground storage tank at Plant 2 is currently not in
active use and is not DHEC-permitted for operational distribution. It has been informally
maintained for fire department access only. Getting that tank permitted, cleaned, disinfected, and
fully operational was identified as an immediate priority that would provide meaningful relief in
both water storage and fire suppression capacity. He also noted that Plant 2's controls are not
configured for automated chlorine management at scale, making operation labor-intensive.
Mr. Cross raised the issue of unauthorized water withdrawal, specifically citing observed instances
of construction contractors filling tanker trucks at Town fire hydrants. He stated that the recently
appointed fire inspector had personally witnessed this activity and that photographic
documentation had been obtained. He urged Council to pursue enforcement action and called for
increased staffing to provide adequate field presence.
He further recommended that the Town require separate irrigation meters for all future
connections, so that domestic water use and landscape irrigation are metered independently,
enabling tiered rate enforcement and demand management. He noted that current rate structures
do not distinguish between meter sizes or use types, creating a significant equity and sustainability
problem.
Page 3 of 7
APPROVED
Dema
nd, Capacity, and Growth — Panel Discussion
Councilwoman Wendy Helms raised the central concern of long-term capacity planning. She noted
that her neighborhood alone had grown from 13 to approximately 41 homes, with further
development underway. She questioned whether the system could realistically sustain 600 to 800
additional homes, and whether planning was accounting for the actual fixture-unit demand of
large, multi-bathroom homes rather than the standard 242-gallon-per-day-per-household figure
used in prior calculations.
Mr. Cross and Mr. Seabrook both acknowledged that the 242 gallon-per-day estimate is a historical
engineering benchmark that does not reflect the actual consumption patterns of newer, larger
homes with multiple bathrooms and irrigation systems. Mr. Cross noted that the system is
currently committed to serving 537 units beyond the existing 400 residential and 36 commercial
accounts, based on agreements already in place with developers.
Council Member Kent Prause asked whether the existing water supply volume—independent of
quality—was sufficient to serve anticipated growth. Mr. Seabrook confirmed that the two
operational wells have the physical pumping capacity to produce adequate volume, but that water
quality, distribution infrastructure, storage, and treatment capability are all constraining factors
that must be addressed as growth continues.
Town Administrator Katharine Watkins clarified that discussions with staff and professionals had
already identified a policy direction of prohibiting irrigation meters tied to the Town's water system
for all new development connections, limiting new connections to domestic use only. This was
noted as a meaningful demand management tool, though Council Member Prause questioned the
legal authority to enforce such a requirement, and no formal action was taken on this point during
the meeting.
The panel also discussed the system's vulnerability in emergency scenarios. Mr. Cross stated that
with only one well pumping at full capacity and the Plant 2 tank unavailable, the fire suppression
reserve could be depleted within approximately one to one and a half hours during a structure fire.
He noted that a simulation had previously been conducted and that results were concerning. The
Town has no backup generator, meaning a power outage would render the entire water system
inoperable. This was identified as an unacceptable risk given the growth in the service area.
Water Rates — Panel Discussion
Council Member Prause noted that the current residential water rate of $4.00 per thousand gallons
for the first 5,000 gallons and $5.00 per thousand gallons thereafter has not been increased in
approximately 17 years. He observed that a household using the national average of approximately
300 gallons per day would generate a monthly water bill of only $40.00, which is far below rates in
comparable systems. Mr. Cross agreed that the rates are deeply underpriced and stated that the
Town is subsidizing usage rather than recovering costs.
Mr. Cross recommended implementing a steeply tiered rate structure that creates strong financial
disincentives for high-volume use, particularly for irrigation. He also recommended differentiating
rates by meter size, noting that some commercial and multi-family connections have 1.5-inch or 2-
inch meters but pay the same rates as standard residential accounts.
South Carolina Rural Water Association — Brandon Abernathy
The South Carolina Rural Water Association (SCRWA) representative, Brandon Abernathy, outlined
the organization's role as a provider of free technical assistance to rural water systems in the state.
He noted that SCRWA has 21 staff members with specializations spanning treatment, distribution,
Page 4 of 7
APPROVED
finance, wastewater, and regulatory compliance. He offered to assist the Town in identifying
comparable systems that have addressed similar challenges, and to help develop ordinances,
drought response plans, and rate structures based on proven models. He also noted that the
Town's failure to raise rates for 17 years makes it currently ineligible for most available grant
programs, as grant agencies evaluate financial sustainability before awarding funds. He strongly
encouraged the Town to conduct a formal rate study and adopt a rate ordinance that includes at
minimum an annual inflation-based adjustment, as a prerequisite to pursuing grant funding.
Brandon also emphasized the importance of separating irrigation from domestic service at the
meter as both a regulatory compliance matter (cross-connection control) and a demand
management tool and noted that a formal drought response plan should be adopted by ordinance,
reviewed annually, and clearly define Stage A, B, C, and D response actions.
He confirmed that SCRWA does not itself provide grants, but that significant funding is available
through the State Revolving Fund (SRF) and USDA Rural Development (RD), and that he was
prepared to assist the Town in navigating those application processes. He noted that grant awards
in the range of $150,000 to $1,500,000 are regularly made to similarly situated systems, but that
recipients must demonstrate financial sustainability to qualify.
9. Consideration of Recommendations post Discussion
Following the panel discussion, Mayor Crolley summarized the consensus priorities identified
through the evening's discussion. No formal votes were taken on individual recommendations, but
the following action directions were affirmed through Council deliberation:
• Emergency Generators — Identified as the immediate top priority. The Town does not
currently have permanent backup power for either plant. Grant opportunities through
emergency management programs are to be pursued. It was noted that grant applications
have already been initiated.
• Plant 2 Ground Storage Tank — Activation of the existing 200,000-gallon ground storage
tank at Plant 2 was identified as a near-term priority already budgeted in the current fiscal
year. Mr. Siebert confirmed he is prepared to submit the necessary DHEC permit
applications. Council was advised that this process, while potentially expedited, could take
considerable time. The tank requires cleaning, disinfection, booster pump installation, and
operational controls before it can be brought online for distribution use. The addition of an
aeration component on top of the tank to address hydrogen sulfide was recommended by
Mr. Bycroft as a cost-effective enhancement to incorporate during the same construction
phase.
• Water Rate Study and Rate Increase — Council acknowledged the urgent need for a formal
rate study and a subsequent tiered rate increase. It was noted that rates have not been
adjusted in 17 years, that the current structure does not reflect the true cost of service, and
that maintaining the status quo is financially unsustainable and disqualifies the Town from
grant programs. The rate study was described as a prerequisite to all capital improvement
grant applications.
• Separation of Irrigation and Domestic Meters — Council affirmed the policy direction of
requiring separate meters for irrigation versus domestic use in all future connections and
discussed the possibility of implementing this requirement through ordinance. This was
identified as essential to demand management, rate equity, and system sustainability.
Page 5 of 7
APPROVED
• Sta
ffing — Mr. Cross and Mayor Crolley both acknowledged that the current staffing level is
insufficient to manage the growing system, respond to emergencies, maintain flushing
schedules, and conduct field monitoring. Increased staffing was identified as a necessary
investment.
• Long-Term Treatment System — Council acknowledged that a formal water treatment
system—potentially utilizing ozone generation, aeration, or other approved oxidation
technology—represents the ultimate solution to the hydrogen sulfide problem, but that
permitting alone could take one to three years, and that this is a long-term capital project
requiring significant funding, design, and regulatory approval. In the interim, Council
acknowledged that point-of-use filtration at individual homes remains the most practical
near-term remedy for residents experiencing odor issues.
• Grant Applications and SCRWA Partnership — Council expressed strong support for
formalizing its relationship with the South Carolina Rural Water Association and directed
staff to begin pursuing all available grant opportunities, including generator grants through
emergency management, and infrastructure grants through SRF and USDA Rural
Development.
• Enforcement of Unauthorized Water Use — Mayor Crolley and Mr. Bycroft noted
documented instances of construction contractors withdrawing water from Town fire
hydrants without authorization. Council directed that enforcement action be pursued using
documented evidence, including a report from the Town's fire inspector.
10. Closing Remarks
11. Mayor Crolley thanked the water professionals and the Rural Water Association representative for
their time and expertise. He acknowledged that while the problems facing the water system are
serious and will not be resolved immediately, the meeting had clarified both the nature of the
challenges and the path forward. He encouraged Council and staff to continue working
collaboratively and indicated that the relationships formed with SCRWA and the engineering team
would be instrumental in moving solutions forward.
12. Adjournment
Motion: To adjourn was made by Councilwoman Wendy Helms and seconded by
Councilwoman Grace Gasper.
Discussion: None
Vote: The motion passed unanimously.
The meeting adjourned at 8:04 pm
DRAFT Minutes Respectfully Submitted on Tuesday, August 4th, 2026, by Takeya White Final
Approval Date: August 6th, 2026 Electronic Signature: Takeya D. White
Note: These meeting minutes are not verbatim. To watch the full meeting video, please
visit the town’s YouTube channel: https://www.youtube.com/@TownOfAwendaw
Page 6 of 7
APPROVED
Notice of Meeting: In accordance with the SC Code of Laws, 1976, Section 30-4-80(d), as amended, the following have been
notified of the time, date, place, and agenda of this meeting. The agenda was posted on the bulletin board at Town Hall prior to
the meeting.
Page 7 of 7
Source: Town of Awendaw website. First collected Oct 16, 2026.