PC-Packet-9-10-26.pdf(PDF, 474KB)
Town of Pendleton · Anderson County · meeting of Sep 10, 2026 · Agenda packets
Open the original document More from Town of Pendleton
This document is no longer listed on Town of Pendleton's website. We kept the copy we read.
Text
Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.
Page 1 of 1
Town of Pendleton
Planning Commission
Regular Meeting
September 10, 2026
Pendleton Town Hall, 6:00 pm
AGENDA:
1. Call to Order:
2. Approval of prior meeting minutes: (Postponed until the next regular meeting).
3. Public Comments.
4. Work Session
a. Work Session: Work session on items from Resolution 03-2026.
i. Continue working on and developing amendments to the Zoning
Ordinance.
5. Adjournment:
PROPOSED AMENDMENTS TO THE EXISTING TOWN ZONING ORDINANCE AND LAND
DEVELOPMENT REGULATIONS
Resolution Item a. Anderson County Stream Buffers
1. Amend Section 2-2 Definitions to add the following:
Riparian Buffer means a naturally vegetated or enhanced vegetated area adjacent to a stream, river,
lake, wetland, or other jurisdictional waterbody that is intended to protect water quality, reduce
erosion and sedimentation, preserve streambank stability, mitigate flooding, and support aquatic and
terrestrial habitat.
2. Amend Section 6-2 to add Section D. Riparian Buffers and add the below text:
D. Riparian Buffers
1. Purpose.
Riparian buffers are established to:
a. Promote public health by protecting private and public drinking water supplies from
excessive non-point source contaminants, including sediment, chemicals, pollutants, and
nutrients.
b. Support natural resources by enhancing wildlife habitat, including wildlife corridors,
fisheries, and the quality of water bodies.
c. Prevent and control flooding, storm damage, and erosion through more even
dissipation of drainage flows.
d. Enhance the scenic and recreation qualities of publicly utilized water bodies; and
e. Promote and protect the public health, safety, order, appearance, prosperity, and
general welfare.
2. Generally:
a. Applicability:
Riparian buffers shall apply to all Waters of the State (WoS), including wetlands, for all
new development requiring an approval for stormwater management in accordance with
the “Anderson County Stormwater Design Manual”.
i. The “Anderson County Storm Water Design Manual” is adopted as part of this
Ordinance.
ii. The current “Anderson County Storm Water Design Manual,”as amended at the date
of the development application will apply.
b. Exemptions:
i. Activities with approval by a State or Federal Agency for Sections 401 or 404 of the
Federal Clean Water Act.
ii. New development or redevelopment where a larger common plan of development has
prior approval of encroachments into riparian buffers.
iii. Man-made ponds, lakes, and ditches which are outside natural hydrologic
connectivity and those created for stormwater management under an NPDES permit
or Anderson County stormwater management approval.
c. Manual and Specifications:
i. Applicants must fully comply with "Anderson County Technical Specification WQ-08
Permanent Water Quality Stream Buffers" for concentrated discharges to a buffer from
new impervious area not receiving post-construction water quality treatment.
ii. The "Anderson County Technical Specification WQ-08 Permanent Water Quality Stream
Buffers" is adopted as part of this Ordinance.
iii. The current "Anderson County Technical Specification WQ-08 Permanent Water Quality
Stream Buffers" at the date of the development application will apply.
d. Delineation:
i. All relevant wetlands shall be delineated by a certified licensed professional using U.S.
Army Corps of Engineers and SCDES's Water Classifications and Standards and shall be
shown in the Storm Water Management and Sediment Control Plan along with all
riparian buffer areas.
3. Standards:
a. Riparian Buffer Requirements:
i. A minimum 50-foot riparian buffer as measured from the top of the stream bank
inland on each side of all WoS where the watershed is less than 50 acres.
ii. A minimum 100-foot riparian buffer as measured from the top of the stream bank
inland on each side of all WoS where the watershed is 50 acres or more.
b. No Disturbance. Within a riparian buffer, the existing vegetation shall not be cleared or
disturbed. Grading, stripping of topsoil, plowing, cultivating, filling, or storage of materials
and machinery are prohibited within the buffer.
c. Encroachments. The following structures and activities are permitted within the riparian
buffer if approved by the Town of Pendleton Planning Commission:
i. Utilities
ii. Road crossings, bridges, and trails
iii. Agriculture and Silviculture
iv. Scientific studies, including water quality monitoring and stream gauging
v. Stream restoration projects
vi. Removal of hazard trees and invasive species
vii. Dock and bulkhead installation and repair
Resolution Item b. Historic Overlay District
The Planning Commission and Staff will research and bring back a new Historic Overlay District.
Resolution Item c. Public Tree Ordinance
1. Amend Section 2-2 Definitions to add the following:
Canopy Tree means a tree that normally attains a DBH in excess of 25 inches and a height in
excess of 45 feet at maturity.
2. Amend Section 6-2 to add Section E. Tree Protection and add the below text:
E. Tree Protection
1. General
a. Purpose. The purpose and intent of this Section is to protect existing tree cover;
facilitate the incremental growth of the Town’s tree canopy; enhance and preserve
the environmental and aesthetic qualities of the City; encourage site design
techniques that preserve the natural environment and enhance the developed
environment; control erosion, slippage, and sediment runoff into streams and
waterways; increase slope stability; improve air quality; protect wildlife habitat and
migration corridors; and reduce homeowner energy costs.
b. Applicability. Except as stated herein, the requirements of this Section apply to all
land-disturbing activities that require permit for existing and new development,
including a grading permit, building permit and compliance letter.
c. Exemptions. The following developments and activities are exempt from this Section
except where otherwise noted below.
i. The removal of diseased, dead or naturally fallen trees as determined by a certified
arborist, licensed landscape architect or the Zoning Administrator; or trees that are
found to be a threat to the public health, safety, or welfare by a TRAQ certified arborist
or the Zoning Administrator.
ii. The selective and limited removal of vegetation or trees under 10 inches in diameter at
breast height is necessary to obtain clear visibility at driveways or intersections, or for
the purpose of performing authorized field survey work.
iii. The removal of trees within operationally active utility easements to maintain their
intended function.
iv. The removal of trees or vegetation on land that is being used for agricultural and
forestry activities, including tree farms and approved forestry management practices,
except that if a site is substantially cleared of trees pursuant to legitimate agricultural
or forestry activities, no development applications will be accepted for 36 months
from the date the clearing is completed. It is the burden of the property owner to
prove that any timber harvesting or land clearing is conducted as a commercial timber
operation. A forestry plan must be submitted that demonstrates that the intended
forestry activities will contribute to the long-term production of marketable forest
products and ensure the continued existence of forests through regeneration.
Conducting a timber sale as the sole timber management activity does not constitute a
“commercial timber operation.”
v. .
vi. Tree clearing or cutting performed to comply with aeronautic safety requirements
mandated by federal or State law or regulation.
d. Tree Protection Zone (TPZ). Before and during any land disturbance, construction, or
development, the following measures shall be utilized to protect trees, including tree
crowns and roots, designated for retention on development plans. The location of the TPZ
fencing and method of construction shall be noted on the site plan.
i. Prior to clearing/grading/land disturbance, construction, and/or development of a
property, the owner shall install all tree and root protection necessary to protect
identified canopy and understory trees from damage.
ii. All trees shall be protected with a sturdy and visible fence before any land disturbance
begins. At a minimum, such Tree Protection Zone (TPZ) shall be established and be equal
to a one-foot radius on the ground for every inch of Diameter at Breast Height (DBH) or
the extent of the drip line of each canopy and understory tree to be protected,
whichever is greater.
iii. Tree protection fencing shall be installed and remain in place and in good condition until
all clearing/grading/land disturbance, development, and construction activities are
completed.
iv. The TPZ fencing shall be constructed from any material visible and substantial enough to
prohibit and keep out vehicles, people, and all other activities associated with the
clearing/grading/land disturbance, development, and construction process. Examples
include wood posts and rails, chain link fencing, wire fencing and posts, and other
substantial materials. Tree protection fencing shall be a minimum of four feet high.
v. All Tree Protection Zones shall be designated as such with signs posted visibly on all
sides of the fenced protection area, with lettering and colors that provide maximum
readability in terms of distance and contrast.
vi. No soil disturbance or compaction, stockpiling of soil or other construction, paving, or
landscaping materials, vehicular traffic, or storage of heavy equipment is allowed in the
tree protection zones of trees to be retained.
vii. In situations where strict adherence to the provision of tree protection zones is not
possible due to factors including, but not limited to, site conditions, overlapping tree
protection zones, or grade changes, the Zoning Administrator may, through field
determination and consultation, allow modifications to the required tree protection
zone.
2. Tree Inventory. The tree inventory and protection plan must be submitted with an
application for any land development activity, as defined in Section 6.2.E.1.b in this
ordinance, that is not otherwise exempt.
a. A legible tree inventory must be submitted as part of an application for any land
disturbing permit or activity, including storage or staging of equipment. The inventory
must show all heritage trees and trees greater than 8 inches DBH to be removed (or for
residential property consisting of an existing single-family home trees that meet the
heritage tree definition), and any tree to be retained. Trees must be clearly identified on
the tree survey as either to be removed or retained. Each retained tree should have its
critical root zone identified to determine impacts.
i. The tree inventory must include any boundary trees, i.e., trees on neighboring
properties, which may experience any land disturbance, including storage of equipment
or other material, within their critical root zone. In cases where the boundary tree
cannot be accessed by a surveyor, the dripline can be substituted for the critical root
zone.
ii. Invasive tree and prohibited tree species, all species listed on the South Carolina Invasive
Species List and all Pinus species, except the Longleaf Pine, Eastern White Pine and
Loblolly Pine are exempt from tree protection requirements.
iii. Encroachment within the critical root zone, or dripline, if the tree cannot be accessed by
a surveyor, of trees located on adjacent properties is not allowed without written
approval from that adjacent property’s owner if the tree is to be impacted. If the limits
of disturbance or land disturbance activity may reasonably be expected to occur within
the critical root zone, or dripline as defined above, of trees located on adjacent
properties, a letter from the tree’s owner may be provided in lieu of tree protection for
the tree. The letter must clearly state that the tree’s owner is aware of the risk to the
tree, that the land disturbing activity may result in the immediate or long-term death or
demise of the tree, and that the Town is not responsible for any damage or removal of
the tree or its parts. The letter must be signed by the adjacent property owner and
included with the tree inventory.
3. Tree Removal and Replacement. Any development or redevelopment activity that results in
the removal or injury of canopy trees 8 inches or greater in DBH (or for residential property
consisting of an existing single-family home, trees that meet the heritage tree definition),
that are not listed in Section 2.a.ii as invasive or prohibited species , must provide
replacement or mitigation equal to or greater than the cumulative DBH of the trees
removed and/or injured as follows:
a. Canopy trees required to meet landscape requirements per the Development Code may
be used to meet tree replacement requirements.
b. Tree loss mitigation may be provided by retaining existing canopy trees on site, which
meet the following criteria:
i. Trees are between 3 inches and 6 inches DBH;
ii. Trees are in good health and are free of damage or disease, as verified by a certified
arborist; and
iii. Trees are not a recognized invasive or prohibited species, as listed in Section 2.a.ii.,; and
iv. Trees are not within an active utility easement.
c. Heritage Tree Protection.
In order to protect significant trees, the city has established the
Heritage Tree designation. The purpose of the heritage tree designation is to encourage the
early identification of significant trees to be saved, thus resulting in developments that are
more responsive to their environments and appear more mature upon completion.
i. For all residential properties consisting of an existing single-family home, any activity that
results in the removal or injury of trees that meet the Heritage tree definition must
provide replacement or mitigation equal to or greater than the cumulative DBH of the
trees removed and/or injured
ii. A heritage tree is a tree that is in a healthy and disease-free condition, and is:
(a) 20 inches or greater DBH, located within the setback or
buffer area of any property within the city
(b) 40 inches or greater DBH, located anywhere within the city; or
(c) determined to be of cultural importance by the administrator
located anywhere within the city. “Cultural importance” for the
purposes of this subsection shall mean the historic significance
of the tree as it may relate to an event or person.
iii. In addition to the tree mitigation outlined in section 19-6.3.2(B), a heritage tree
which is removed shall be assessed with a fee of $45 per caliper inch.
iv. No construction, grading, equipment, material storage, or any other activity, shall be
allowed within the critical root zone of a heritage tree unless the steps taken to
adequately ensure the health of the tree are submitted to the planning department in
writing.
v. A Heritage Tree Disturbance Form shall be developed by the administrator and shall
be submitted for the trimming, pruning, encroachment upon, or removal of any
Heritage Tree, which may fall outside of development activities. The form shall be
posted online on the city website and be made available upon request by contacting
the administrator.
vi. Heritage Trees shall not be cut, removed, pushed over, killed, harmed, trimmed,
sprayed, or destroyed without written approval via the Heritage Tree Disturbance
Form.
Page 8 of 19
vii. The administrator shall approve Heritage Tree disturbance only upon a
finding that the tree is in a dangerous or deteriorating condition and poses a
risk to health, safety, or welfare.
d. In cases where tree mitigation is required but planting is not preferred by the
applicant, the Town Administrator must approve a fee-in-lieu-of mitigation via payment
to the Town’s Tree Fund. Fees will be established by Town Council annually through the
Town’s Comprehensive Fee Schedule.. This fee in-lieu of shall not exempt the applicant
from any landscaping requirements such as buffers, screenings, parking lot landscaping,
and other plants required with the development application. The Tree Fund will be
managed by the Town and must be used solely for the purposes of:
i. New tree and vegetation purchase and installation by the Town on public
property.
ii. Maintenance of existing tree canopy on public property and rights-of-way;
iii. Purchase of real property for the purposes of tree plantings or dedicated open
space; or
iv. Administration of the above.
v. The total tree mitigation fee may be reduced by a percentage equal to the
percentage of affordable housing units included within the project as
documented by the Town.
4. Tree Coverage Requirements. In addition to the standards laid out within this
Section, land or property shall maintain a minimum baseline canopy coverage area
based on the zoning district and lot size. This canopy can be comprised of existing
trees, new trees, or a combination of both, and shall be per the table below:
Table 6.3: Tree Coverage Requirements
Type of Development Minimum Number of Trees Required*
1 Canopy/Overstory Tree Required
Single Family Residential, Detached Per 4,000 sq. ft. of lot size
Page 9 of 19
Attached Single Family, Two-family, three-family
dwellings
Per 6,000 sq. of lot size
Multi-Family Per 4,000 sq. ft. of lot size
Town Center N/A
Lodging & Mixed Use Per 6,000 sq. ft. of lot size
Office, Commercial, & Vehicular Per 6,000 sq. ft. of lot size
Civic & Institutional Per 8,000 sq. ft. of lot size
Industrial N/A
*Approved existing vegetation, buffer trees, street tress, landscaping islands, etc. could all count
towards this requirement.
Resolution Item d. Sidewalk Requirements and Connectivity
1. Amend Sections of the Town of Pendleton Land Use Regulations to repeal Section 7.11
Sidewalks and replace with the below text:
SECTION 7.11 SIDEWALKS
1. Design Specifications.
a. Sidewalks are required to be a minimum of five (5) feet wide according to ADA
(Americans with Disabilities Act) Standards.
b. Sidewalks shall be placed parallel to streets, with exceptions permitted to
preserve natural features, or to provide visual interest, or where required for
pedestrian safety.
c. Design and location of sidewalks shall connect with existing pedestrian
infrastructure.
d. Sidewalks are required on both sides of all newly constructed roads and along
the entire road frontage of all newly constructed commercial development.
Sidewalks must be constructed at the front of the property from property line to
property line, regardless if there are sidewalks present on adjacent parcels.
2. Construction Specifications
Page 10 of 19
a. Sidewalks shall be four (4) inches thick except at points of vehicular crossing
where they shall be at least six (6) inches thick. At vehicular crossings, sidewalks
shall be reinforced with welded wire fabric mesh or an equivalent.
b. There shall be a minimum distance of two (2) feet between the back of curbing
to the edge of sidewalk to provide an area for a planting strip and buffer from
vehicular traffic.
c. Expansion Joints: Preformed expansion joints three-quarter (¾) inch thick,
extending the full depth of the concrete, shall be constructed at the locations
indicated on the plans and at other locations as follows:
i. Whenever a sidewalk is constructed between an adjoining substantial structure
on one side and curbing on the other side, an expansion joint shall be formed
adjacent to the curbing.
ii. An expansion joint shall be placed between the sidewalk and the radius curbing
at street intersections.
iii. When sidewalks are constructed adjacent to existing or new pavements or
structures, expansion joints shall be placed to match these existing joints.
iv. Sidewalks shall be installed in accord with Section 720 of the Standard
Specifications for Highway Construction Manual, Latest Edition, as amended.
d. Contraction Joints: The concrete slabs in sidewalks between expansion joints
shall be divided into blocks five (5) feet in length by scoring transversely after
floating operations are complete. Whenever the sidewalk slabs are more than
ten (10) feet in width, they shall be scored longitudinally in the center. All scoring
shall extend for a depth of one (1) inch and shall not be less than one-quarter
(1/4) inch or more than one-half (1/2) inch in width. All scoring shall be edged
and finished smooth and true in line.
e. Graded areas shall be planted with grass or treated with other suitable ground
cover, and their width shall correspond to that of sidewalks.
3. Bonding Requirements. The bond requirement for sidewalks is 150% of the
estimated construction costs for all sidewalks required by the provisions of this
ordinance. The contractor may secure the bond to allow for installation at the closing
stages of the phase or complete development of the project. The contractor must
Page 11 of 19
secure approval from the Director of Public Works and the Zoning Administrator to
bond sidewalk installation and improvements.
Resolution Item e. Generalized Design Standards
1. Amend Section 6 of the Town of Pendleton Zoning Ordinance to add Section 6.11 General
Design Standards
SECTION 6-11 GENERAL DESIGN STANDARDS
All commercial or residential development or redevelopment that are not located in a Town of
Pendleton Overlay District must meet the below requirements:
A. Site Design Standards
1. Building Orientation
a. Buildings shall be oriented toward public streets, sidewalks, parks, or other
public spaces.
b. Primary entrances shall face the primary street whenever practical.
c. Corner lots shall provide architectural features and entrances that address both
street frontages.
2. Pedestrian Design
a. Development shall be designed to encourage pedestrian movement.
b. Buildings shall be connected to public sidewalks and parking areas by clearly
defined pedestrian walkways.
3. Building Placement
a. Buildings within the same development should maintain consistent setbacks and
orientation.
b. Commercial buildings should generally be located near the street to define the
public realm.
4. Parking
a. Parking shall be located beside or behind buildings whenever practical.
Page 12 of 19
b. Parking lots serving Commercial Complexes, Group Developments or Mixed Use
Development shall be divided into smaller parking areas through landscaping,
pedestrian connections, or landscaped islands.
c. Parking areas adjacent to public streets shall be screened with landscaping.
5. Streetscape
a. Development shall contribute to an attractive streetscape through the use of
sidewalks, street trees, landscaping, pedestrian-scale amenities, and coordinated
site design.
b. Street trees that are of an appropriate size and type for each site shall be
installed where required by the Section 6-2 Landscaping, Buffering and Screening
Requirements of the Town’s Zoning Ordinance.
B. Building Design Standards
1. Human Scale
a. Buildings shall incorporate architectural elements that reduce perceived mass
and create visual interest.
b. Long blank walls shall be avoided.
c. Large buildings shall incorporate changes in wall plane, roofline, materials,
windows, or other architectural features to reduce visual monotony.
2. Building Articulation
a. Buildings visible from public streets shall incorporate a clearly defined base,
body, and roofline or parapet.
b. Changes in materials, projections, recesses, porches, balconies, or similar
architectural features shall be used to create visual interest.
3. Entrances
a. Primary entrances shall be clearly identifiable through architectural features such
as porches, stoops, canopies, awnings, recesses, columns, or similar elements.
b. Corner commercial buildings are encouraged to provide entrances oriented
toward both streets.
4. Windows
a. Windows shall be proportionate to the building and arranged in an orderly
pattern.
b. Buildings facing public streets shall include windows that provide visual interest
and reduce blank wall areas.
Page 13 of 19
c. Reflective or mirrored glass is prohibited.
5. Roof Forms
a. Roof forms shall be compatible with the architectural style of the building.
b. Flat roofs shall include parapets or other architectural treatments.
c. Mechanical equipment shall not be visible from adjoining public streets.
C. Architectural Character
Development shall reflect traditional architectural forms and proportions commonly found
throughout Pendleton while allowing contemporary interpretation.
Architectural styles may include, but are not limited to:
1. Traditional Southern
2. Craftsman
3. Colonial Revival
4. Vernacular
5. Farmhouse
6. Traditional Commercial
7. Contemporary designs compatible with surrounding development
Buildings shall avoid excessive ornamentation or architectural features unrelated to the overall
design.
D. Building Materials
Exterior building materials shall be durable, high-quality, and appropriate for the architectural
style.
Preferred materials include:
1. Brick
2. Natural or manufactured stone
Page 14 of 19
3. Fiber-cement siding
4. Wood siding
5. Stucco
6. Standing-seam metal roofing
7. Architectural asphalt shingles
The following materials are discouraged or prohibited as primary exterior materials on principal
façades:
1. Bare concrete masonry units (CMU)
2. Reflective or mirrored glass
3. Highly reflective metal panels
4. Bright synthetic colors
5. Faux stone of poor quality
6. Corrugated metal siding on principal façades (except where approved as an architectural
feature)
Accessory buildings shall utilize materials compatible with the principal structure.
E. Color Palette
1. Exterior colors shall complement Pendleton's traditional architectural character.
2. Muted earth tones, natural colors, and historic color palettes are encouraged.
3. Accent colors may be used for doors, shutters, trim, and architectural details.
4. Highly fluorescent or intensely reflective colors are prohibited.
E. Residential Design Standards
Residential development shall reinforce traditional neighborhood character and must comply
with Section 6-10 Infill Development Design Guidelines.
1. Front entrances shall be clearly visible from the street.
2. Front porches or stoops are encouraged and shall be required where specified by an
Overlay District.
Page 15 of 19
3. Attached garages facing the street shall be recessed from the primary façade
whenever practical.
4. Garage doors shall not dominate the front elevation.
5. Rooflines shall incorporate gables, hips, dormers, or similar architectural features to
create visual interest.
6. Accessory structures shall be compatible with the principal building in materials, roof
form, and architectural character.
7. Multifamily buildings shall incorporate building articulation, varied rooflines, and
four-sided architecture.
F. Commercial Design Standards
Commercial buildings shall reinforce an attractive pedestrian-oriented environment.
Commercial infill development and redevelopment shall be constructed in a manner that
is compatible with the size, color or materials of adjacent properties and properties
located on the same street.
1. Primary entrances shall face public streets.
2. Ground-floor façades facing public streets shall incorporate transparent windows
and active building frontages.
3. Buildings shall include architectural details such as cornices, awnings, canopies,
recessed entrances, columns, or similar features.
4. Blank walls facing public streets shall be avoided.
5. Outdoor seating, plazas, courtyards, and pedestrian gathering areas are encouraged.
6. Service areas, loading facilities, and dumpsters shall be located behind or beside
buildings and screened from public view.
G. Sustainability
Development should minimize impacts on natural resources through site-sensitive design.
The following practices are encouraged:
1. Preservation of mature trees where practical.
2. Minimization of grading and land disturbance.
3. Reduction of impervious surfaces.
4. Native and drought-tolerant landscaping.
5. Stormwater management practices that promote infiltration and water quality.
6. Underground utilities where practical.
7. Building orientation and landscaping that improve energy efficiency and provide
shade.
Resolution Item f. Lighting Regulations
Page 16 of 19
1. Amend Section 2-2 Definitions to add the following:
Lumens (lm) means a measure of the total amount of light emitted by a fixture.
Footcandles (fc) means a measure of the amount of light that falls on a surface (1 footcandle =
1 lumen per square foot).
2. Amend Section 6-2 to add Section F. Lighting and add the below text:
F.
LIGHTING
1. General
2. Purpose. The purpose of this section is to regulate exterior lighting to enhance the areas
being lit, help ensure the safety of pedestrians, cyclists, and drivers, and minimize light
spillage and glare.
3. Applicability. The provisions of this section shall apply to:
a. All development in the Town of Pendleton, future annexations, and all lighting
fixtures installed after the effective date of this Code.
Replacement of site lighting and changes to existing light fixture wattage, type of fixture,
mounting or fixture location must be made in compliance with this Section.
4. Exemptions. The following lighting types shall be exempt from the requirements of this
section:
a. Street lighting, which is regulated separately under Section 4.5.9.
b. All temporary emergency lighting needed by the Police or Fire Departments or other
emergency services, as well as all vehicular lights.
c. All hazard warning lights required by Federal regulatory agencies and in compliance
with adopted standards.
d. Individual residential lighting that is not part of a site plan or subdivision plan for
street or other common or public area outdoor lighting.
e. Lighting associated with holiday, festival, or other temporary uses.
f. Lighting of public art that has been permitted or otherwise approved by the Town.
Page 17 of 19
g. Other Municipal or State lighting installed for the benefit of public health, safety, and
welfare.
h. All fixtures installed or temporarily used by public agencies, their agents, or
contractors for the purpose of illuminating public streets.
i. Lighting of US and South Carolina State Flags.
j. Routine maintenance of all existing fixtures.
ii. Standards
The following standards are required of all exterior lighting, with the exception of street
lighting:
a. Design. Exterior lighting shall be consistent with the architectural character of the
building.
b. Location
i. Fixtures shall be placed to provide uniform distribution of light and to avoid
intense lighting that produces excessive glare.
ii. All lighting poles shall be located at least 10 feet from property lines defining rear
and side yards.
iii. Light sources shall not be located within any perimeter-landscaped areas with
the exception of pedestrian walkways.
c. LED Lighting. The use of LED lighting or other high-efficiency lighting equal shall be
permitted but must meet the maximum illumination standards for each type of lighting
set forth in this ordinance.
iii. Shielding
a. Building lighting and landscaping lighting shall be located, aimed, and shielded so
that direct illumination is focused exclusively on the building facade, building
foundation, plantings, or other site features and away from adjoining properties and
the street right-of-way.
Page 18 of 19
b. Any upwardly directed lighting used to illuminate structures shall be limited to low-
wattage architectural lighting.
c. Lighting used to illuminate pedestrian walkways, and signage shall be downcast or
cutoff type lighting fixtures.
iv. Maximum Height. The maximum height as measured from grade for outdoor lighting,
except outdoor recreation and performance areas, shall be:
a. Non-Cut-Off Lights: 12 feet
b. Cut-Off Lights: 25 feet
v. Hours of Illumination. Public and institutional uses, commercial uses, and industrial
uses (heavy and light) shall turn off all exterior lighting within 1 hour after closing,
except for lighting necessary for security or emergency purposes.
vi. Parking Lot Lighting. Parking lots and vehicular use areas shall be lit for efficient use
during hours of darkness. Specifically, lighting will not illuminate, nor cast glare into
neighboring properties nor in the eyes of motorists. Lighting fixtures shall be part of
the overall project design and contribute to the landscaping effect both in daylight and
dark.
vii. Landscape and Decorative Lighting. Landscape and decorative lighting, of 600 lumens
or less is permitted, provided that the light is installed and aimed to prevent lighting
build up and light spillage.
viii. Maximum Illumination. The maximum allowable light trespass permitted onto a
residential property shall be 0.3 Footcandles as measured at the property line.
Minimum lighting for streets shall be based on County or SCDOT regulations or best
practices.
ix. Security Lighting
a. Motion-activated security lights. Unshielded flood and spotlights, with 675 lumens or
less, installed for security and activated by motion sensor, are permitted. These
unshielded lights must be mounted and aimed in a manner that minimizes up-
lighting and light spillage. The maximum allowable light trespass permitted onto an
adjacent property shall be 0.3 Footcandles as measured at the property line.
Page 19 of 19
b. Floodlights. The visibility of the light source inside a luminaire shall be restricted; the
direct light shall not be visible above six feet at the adjoining public roadway
pavement edge or 15 feet beyond the property line.
c. Lights with Photosensors. Area “dusk to dawn” open-bottom lights, with
photosensors that automatically turn the light on and off at certain levels of ambient
illumination, are permitted. These lights must be full cutoff.
x. Prohibited Lighting
The following types of lighting are prohibited:
a. Lasers. Laser source light or any similar high-intensity light for outdoor advertising or
entertainment that is projected above the horizontal.
b. Searchlights. The operation of searchlights for advertising purposes.
c. Flashing Lights. Flickering or flashing lights.
Source: Town of Pendleton website. First collected Oct 17, 2026.