MARGUERITE BROWN MUNICIPAL CENTER
CITY HALL COUNCIL CHAMBERS
519 N. GOOSE CREEK BLVD.
GOOSE CREEK, SOUTH CAROLINA
1
TO: MEMBERS OF THE ARCHITECTURAL REVIEW BOARD
FROM: LILI ORTIZ-LUDLUM, ADMINISTRATIVE ASSISTANT
DATE: AUGUST 12, 2021
SUBJECT: MEETING NOTIFICATION
WHERE: MARGUERITE H. BROWN MUNICIPAL CENTER
This is to remind everyone that the next meeting of the Architectural Review Board is
scheduled for Monday, August 16, 2021 at 6:00 p.m.
Please review the enclosed packet. Should you have any questions or comments prior to
Monday’s meeting, please do not hesitate to contact Brenda Moneer, Planning and Zoning
Technician (x1116) or Mark Brodeur, Planning and Zoning Director(x.1118) at 843-797-6220.
MEMORANDUM
2
MINUTES
3
MINUTES
CITY OF GOOSE CREEK
ARCHITECTURAL REVIEW BOARD MEETING
MONDAY, JULY 26, 2021, 6:00 P.M.
MARGUERITE H. BROWN MUNICIPAL CENTER
519 N. GOOSE CREEK BOULEVARD
I. CALL TO ORDER, PLEDGE OF ALLEGIANCE AND ROLL CALL
Chairperso
n Dresel called the meeting to order at 6:0 0 p.m. and initiated the Pledge of
Allegiance. Mrs. Moneer initiated roll call.
Present: Ric
ky Dresel, Jen Wise, David Cantrill, Mary Kay Soto, Teri Victor
Absent:
Sharon Clopton, Gary Becker
Staff Presen
t: Planning and Zoning Director Mark Brodeur
Planning and Zoning Technician Brenda Moneer
II. APPROVAL OF MINUTES – JUNE 21, 2021
Motion: A mo
tion was made to accept the minutes as submitted. Moved by
Board Member Wise, Seconded by Board Member Cantrill.
Discussion: None.
Vote: All v
oted in favor (5-0). Motion carried.
III. MINOR APPLICATIONS – NEW BUSINESS
A. 2021- 045 SIG: S
C FEDERAL CREDIT UNION: 82 BRIDGETOWN ROAD – SIGNAGE
A representative p
resented the application. She stated South Carolina Federal Credit
Union is currently upfitting their facility and all new signs will be installed. She stated the
building signs will be halo lit. The monument sign will have push through letters. The
background will be opaque, and the letters will be illuminated. The directional will not
be luminated. Discussion occurred as where the signs will be located. The applicant
stated they will be placed where they are currently existing. Mr. Brodeur stated he would
prefer to see the address on both sides of the monument signs.
Motion: A mo
tion was made to accept the application as submitted. Moved
by Board Member Soto, Seconded by Board Member Wise.
Discussion: Bo
ard Member Cantrill inquired as to the color of the building. The
representative stated she is not sure as to the current color of the
building. Mrs. Moneer presented the proposed rendering of the
scope of work.
4
Amended Motion: An amended motion was made to accept the application as
submitted with the addition that the street number be added to
both sides of the monument sign. Moved by Board Member Soto,
Seconded by Board Member Wise.
Vote: All
voted in favor (5-0). Motion carried.
B. 2021-047 SIG: O
UTLAW BARBER COMPANY: 119 PLANTATION NORTH BLVD,
UNIT C –SIGNAGE
A representative p
resented the application. He stated this business will be located in the
Goose Creek Village. He stated the sign will be internally lit channel letters.
Motion: A mo
tion was made to accept the application as submitted. Moved
by Board Member Wise, Seconded by Board Member Victor.
Discussion: None
.
Vote: All
voted in favor (5-0). Motion carried.
C. 2021-048 SIG: G
OD’S LITTLE MASTERMINDS/ DELIVERANCE & FAITH
MINISTRIES: 107 ST. JAMES AVE, SUITE B1 & B2 – SIGNAGE
A representative p
resented the application. The representative stated he has a change
to this sign and presented to the board a new rendering. He stated it is the same design
that is presented in the packet however he inverted the black and white. The sign will be
opaque with white letters; t he logo will stay the same. He stated this is an existing
cabinet sign that is already on the building. He stated he will remove the current panel
and install a new panel in its place.
Motion: A mo
tion was made to accept the application as presented. Moved
by Board Member Soto, Seconded by Board Member Cantrill.
Discussion: None
.
Vote: All
voted in favor (5-0). Motion carried.
D. 2021-049 ROOF: RI
PLEY’S ACCOUNTING: 205 RED BANK ROAD – REROOF
A representative p
resented the application. He stated Ripley’s Accounting currently has
a flat roof which has caused problems. The proposal is to build over the roof per
engineer’s specifications and put an architectural vinyl siding on the front and vinyl
siding on the back gable ends. The facia would come down to meet the brick line so no
siding will be needed on the sides. The representative presented material samples to the
board.
5
Motion: A motion was made to accept the application as submitted. Moved
by Board Member Cantrill, Seconded by Board Member Wise.
Discussion: None
.
Vote: All
voted in favor (5-0). Motion carried.
E. 2021-050 PT: DRE
AM LEARNING ACADEMY: 100 GOOSE CREEK BLVD – PAINT
EXTERIOR AND FENCE, REPLACE EXTERIOR DOORS AND WINDOW FRAMES
A representative p
resented the application. He stated they are upfitting this building. He
presented a rendering and material samples to the board. It was stated that signage will
be presented at a later date as it was tabled at the last meeting. The board inquired if the
fence would be painted. It was stated that it would be painted gray. Chairman Dresel
stated it would be prudent to make a comment to spruce up landscaping and that it
matches the rendering.
Motion: A mo
tion was made to accept the application as submitted with the
addition that landscape reflects the rendering and is alive and well.
Moved by Board Member Wise , Seconded by Board Member
Cantrill.
Discussion: Mr
. Brodeur stated this site has 96 parking spaces which is a lot for
a facility this size. He stated the Planning Commission has been
struggling with projects that come in over parked. He stated this is
a renovation so he will not suggest the removal of parking spaces,
but this is an area where the City can make a facade grant to this
property, and he would love to see trees planted someplace in this
parking lot . He stated this is a lot of asphalt for this site and
recommends a condition is made for the project that the applicant
speaks to the Economic Development Department to seek a facade
grant. The applicant stated there are plans on the adjacent parcel
that the landowner owns for future development that would use
some of the parking.
Amended M
otion: A motion was made to accept the application as submitted, to
spruce up current landscaping, and to suggest that the applicant
speak with the City’s Economic Development Department for
possible grants to further spruce up the property. Moved by Board
Member Wise, Seconded by Board Member Cantrill.
Vote: All
voted in favor (5-0). Motion carried.
IV. OLD BUSINESS: MAJOR APPLICATIONS
6
A. 2021-051 RENO: MILLER CONWAY LAWYERS: 124 S. GOOSE CREEK BLVD –
SECOND FLOOR ADDITION RENOVATION.
The applicant p
resented the application. He stated they want to add a second story to
the back 1/3 of the building. He stated one point at the last meeting that he wanted to
address today was clarification of the location for the Miller Conway Sign, he stated that
would be submitted on a separate application but did include it on the elevation. He
stated on the side the faces Evatt Stree t, we provided additional screening. He stated
the screening would be a permanent structure with a footing in brick to screen the
HVAC units. The applicant stated greenery was the initial screening that was approved
for the dental office, however, to make everything cohesive, all screening will now be
brick.
Motion: A mo
tion was made to accept the application as submitted.
Moved By: Board Member Soto, Seconded By: Board Member
Victor.
Discussion: T
here was none.
Vote: All
voted in favor (5-0). Motion carried.
V. CLOSING REMARKS AND ADJOURNMENT
Board Memb
er Wise stated the new Brazilian restaurant windows is full of signage.
Mr. Brodeur stated they are aware. Board Member Wise inquired if there is a limit to
how many times a logo can be added to a building. Mrs. Moneer stated as long as they
do not exceed the sign coverage.
Mr. Brod
eur stated recently staff conducted a city-wide review of all the signs existing
in the city . He stated he was surprised to find how many offenders they have of
window signs exceeding the allowable coverage.
Board Memb
er Cantrill inquired as to when the Brewery will open. Mr. Brodeur stated
he was not sure.
Mr. Brodeur
stated one of the changes recommended by the Planning Commission to
City Council is a way to improve the overall aesth etics of the signs w e are receiving.
The Planning Department has noticed a lot of the signs the ARB is asked to approve
are simple plastic replacement signs. He stated these signs tend to be low er quality.
He stated the Planning Commission recommended allowing these signs however they
should have an opaque field and translucent letters. Mr. Brodeur stated this will allow
light to go through so that during the day the business can have whatever background
they want on the sign, but at night all you will see is the illuminated letters of the
signs. It would be a lot clearer and aesthetically pleasing. He stated City Council has
not adopted the sign code yet but there will be a workshop coming up.
7
Board Member Soto stated she was disappointed with the inconsistency of the look
at Goose Creek Village. Mr. Brodeur suggested that the next time a development like
this is in the city we request they come up with a sign program that is of consistent
font, coverage, and placement.
Motion: A m otion w
as made to adjourn (6: 50p.m.) Moved By: Board
Member Cantrill, Seconded By: Board Member Wise.
Discussion: Th
ere was none.
Vote: A
ll voted in favor (5-0). Motion carried.
__________________________________________________________________ Dat
e_____________________________
Ricky Dresel, Chairperson
8
NEW BUSINESS: MINOR APPLICATIONS
2021-053 SIG
LOWCOUNTRY BELL CLUB
219 S. GOOSE CREEK BLVD- SIGNAGE
9
16541
219 S Goose Creek Blvd.
044268
75.00 08/02/2021
YEARLY
10
32sf
11
12
13
NEW BUSINESS: MINOR APPLICATIONS
2021-054 SIG
EXXON
670 COLLEGE PARK ROAD - SIGNAGE
14
044092
75.00PAID
6-29-2021
15
16
17
3URSRVHG6LJQVTIWµ2$+
([LVWLQJ6LJQVTIWµ2$+
18
19
NEW BUSINESS: MINOR APPLICATIONS
2021-055 PT
CROWFIELD PARK PLAZA
119 SPRINGHALL DRIVE - EXTERIOR PAINT
20
21
22
NEW BUSINESS: MINOR APPLICATIONS
2021-056 PT
103 MARILYN STREET - SIGNAGE
23
All exterior painting of a different color requires
ARB Approval. Building "appears" to be residential in
nature but zoning is Commercial (GC)
Please contact Brenda Moneer, at extension 1116
24
25
NEW BUSINESS: MAJOR APPLICATIONS
2021-057 NBLD
TIME TO SHINE
539 ST JAMES AVE - SITE, LANDSCAPE, ELEVATIONS
26
27
28
D:\Jacob Rice\Time to Shine\Goose Creek\Plan Set\Plan Set for ARB_8.2.21.dwgAug 02, 2021 - 4:13pmPrinted By:Alden
803.760.3437
14 CALENDAR CT.
COLUMBIA, SC 29206
PROJECT CONTACTS
CITY OF GOOSE CREEK, SC
ARCHITECTURAL REVIEW BOARD PLANS
FOR
**** THE INDIVIDUALS LISTED ****
HERE-IN ARE INTENDED TO BE POINTS
OF CONTACT AND ARE NOT NECESSARILY
THE PROFESSIONALS OF RECORD. REFER
TO THE INDIVIDUAL DISCIPLINE PLANS
FOR INFORMATION REGARDING THE
RESPECTIVE PROFESSIONALS OF RECORD.
PHONE:
EMAIL:
CONTACT:
SURVEYOR
SURVEYING & MAPPING, LLC (SAM)
6904 N. MAIN ST., SUITE 102
COLUMBIA, SC 29203
DON WILSON
(803)764-1902
DON.WILSON@SAM.BIZ
PHONE:
EMAIL:
CONTACT:
PLANNING & ZONING
CITY OF GOOSE CREEK
519 NORTH GOOSE CREEK BLVD.
GOOSE CREEK, SC 29445
(843)797-6220
PHONE:
EMAIL:
CONTACT:
ENGINEER
JACOB RICE ENGINEERING, LLC
14 CALENDAR CT.
COLUMBIA, SC 29206
ALDEN LIVINGSTON
(803)760-3437
ALIVINGSTON@JACOBRICEENG.COM
TIME TO SHINE AT ST JAMES AVE.
TIME TO SHINE CAR WASH, INC.
PHONE:
EMAIL:
CONTACT:
DEVELOPER/OWNER
TIME TO SHINE CAR WASH, INC.
2814 BYINGTON SOLWAY RD.
KNOXVILLE, TN 37931
MIKE ROPER
MROPER99@COMCAST.NET
DEVELOPED BY
PHONE:
EMAIL:
CONTACT:
STORMWATER
BERKELEY COUNTY
1003 HWY 52
MONKS CORNER, SC 29461
(843)719-4234
LAND DISTURBANCE
±1.3 ACRES
SHEET INDEX
SHT. NO. SHEET NAME
SITE CIVIL
C-001 COVER SHEET
C-002 EXISTING CONDITIONS
C-101 SITE PLAN
C-102 SITE PLAN W/ AERIAL OVERLAY
C-103 LANDSCAPE PLAN
ARCHITECTURAL
A-1 FLOOR PLAN
A-2 EXTERIOR ELEVATIONS
A-3.1 EXTERIOR ELEVATIONS COLOR (EXIT & ENTRY)
A-3.2 EXTERIOR ELEVATIONS COLOR (TUNNEL & OFFICE)
A-4.1 SITE PERSPECTIVES
A-4.2 SITE PERSPECTIVES
A-5.1 BUILDING PERSPECTIVES
8/2/21
GOOSE CREEK
ARCH. REVIEW BOARD
DIAL 811
PHONE:
EMAIL:
CONTACT:
ARCHITECT
FALCONNIER DESIGN
4622 CHAMBLISS AVE.
KNOXVILLE, TN 37919
GRAHAM FOX
(865)584-7868
GRAHAM.FOX@FALCONNIER.NET
IN
GENERAL NOTES:
1. A COMPLETE SET OF APPROVED DRAWINGS MUST BE MAINTAINED ON SITE AT ALL TIMES THAT THE
CONTRACTOR IS PERFORMING WORK.
2. WITHIN ALL NOTES, THE TERM CONTRACTOR SHALL MEAN THE GENERAL CONTRACTOR AND ANY
SUBCONTRACTOR OR VENDOR PERFORMING CONSTRUCTION ON THE SITE.
3. SHOULD THE CONTRACTOR FIND ANY DISCREPANCIES ON THE DRAWINGS, OR IN THE FIELD PRIOR TO
BEGINNING WORK OR DURING CONSTRUCTION, HE SHALL IMMEDIATELY NOTIFY THE ENGINEER.
4. BOUNDARY AND TOPOGRAPY HAS NOT BEEN FIELD VERIFIED BY THE ENGINEER. IT WILL BE THE
CONTRACTOR'S RESPONSIBILITY TO VERIFY EXISTING FIELD CONDITIONS AND REPORT ANY
DISCREPANCIES OR CONFLICTS TO THE ENGINEER PRIOR TO CONSTRUCTION.
5. THE CONTRACTOR IS RESPONSIBLE FOR LOCATING AND VERIFYING ALL UNDERGROUND UTILITIES PRIOR
TO CONSTRUCTION AND IS RESPONSIBLE FOR ANY DAMAGE TO THEM DURING CONSTRUCTION.
CONTRACTOR SHALL CONTACT THE STATE'S LOCATION SERVICE AT LEAST 48 HOURS PRIOR TO
BEGINNING CONSTRUCTION.
6. THE CONTRACTOR SHALL COMPLY WITH ALL RULES AND REGULATIONS OF FEDERAL, STATE, COUNTY AND
LOCAL MUNICIPALITIES.
7. ALL MATERIALS, METHODS, AND DETAILS OF CONSTRUCTION SHALL CONFORM TO THE STANDARD
SPECIFICATIONS AND REGULATIONS OF THE BERKELEY COUNTY, THE CITY OF GOOSE CREEK, SOUTH
CAROLINA DEPARTMENT OF HEALTH & ENVIRONMENTAL CONTROL (SCDHEC), & SOUTH CAROLINA
DEPARTMENT OF TRANSPORTATION (SCDOT).
8. ALL RIGHT-OF-WAY CONSTRUCTION SHALL MEET LOCAL AND STATE DEPARTMENT OF TRANSPORTATION
STANDARD SPECIFICATIONS, LATEST EDITION.
9. THE CONTRACTOR IS REQUIRED TO MEET ALL APPLICABLE FEDERAL, OSHA, STATE, & LOCAL
REGULATIONS CONCERNING PROJECT SAFETY AND ASSUMES FULL RESPONSIBILITY FOR SAFETY ON THE
PROJECT.
10. THE CONTRACTOR SHALL VERIFY THAT ALL NECESSARY PERMITS FOR CONSTRUCTION HAVE BEEN
OBTAINED PRIOR TO THE START OF THE PROJECT.
11. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DAMAGES TO EXISTING INFRASTRUCTURE WITHIN THE
SITE OR ADJOINING PROPERTIES (i.e. PAVEMENT, CURB, SIDEWALK, UTILITIES, LANDSCAPED AREAS
etc.). THE CONTRACTOR SHALL REPAIR/REPLACE ALL DAMAGED ITEMS IMMEDIATELY, IF NECESSARY,
OR PRIOR TO THE END OF THE JOB AND AT NO COST TO THE OWNER IN ACCORDANCE WITH LOCAL
REGULATORY REQUIREMENTS.
12. CONTRACTOR SHALL PROVIDE AS-BUILT RECORDS OF ALL CONSTRUCTION (INCLUDING UNDERGROUND
UTILITIES) TO THE OWNER FOLLOWING COMPLETION OF CONSTRUCTION ACTIVITIES, AS REQUIRED.
13. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING INSTALLATION OF ALL UTILITIES BY THE
APPROPRIATE UTILITY COMPANY AND SUBCONTRACTORS PERFORMING WORK TO AVOID CONFLICTS. THE
CONTRACTOR IS ALSO RESPONSIBLE FOR SCHEDULING INSTALLATION OF ALL UTILITIES IN A TIMELY,
ORGANIZED, AND SYSTEMATIC MANNER.
14.IN THE EVENT OF A CONFLICT WITH WATER, SEWER, DRAINAGE OR OTHER UTILITY LINES, THE
CONTRACTOR SHALL COORDINATE WITH THE ENGINEER PRIOR TO MAKING FIELD ADJUSTMENTS.
15. THE CONTRACTOR IS RESPONSIBLE FOR THE REMOVAL AND DISPOSAL OF ALL RUBBISH, TRASH, DEBRIS,
AND ORGANIC MATERIAL etc. IN A LEGAL MANNER.
16. THE CONTRACTOR SHALL REFERENCE THE PROJECT GEOTECHNICAL REPORT AND COMPLY WITH ALL REPORT
RECOMMENDATIONS. IF A CONFLICT ARISES BETWEEN CIVIL DOCUMENTS AND GEOTECHNICAL REPORT,
THE MORE STRINGENT SHALL GOVERN.
SITE VICINITY MAP - 1"=1500'
539 ST JAMES AVE.
GOOSE CREEK, SC 29445
OLD MT. HOLLY RD
ST. JAMES AVE
PROJECT SITE
PHONE:
EMAIL:
CONTACT:
CONTRACTOR
WILD BUILDING CONSTRUCTION, INC.
225 W. 1st NORTH STREET, SUITE 102
MORRISTOWN, TN 37814
LANCE WILDS
(423)581-5639
LANCE@WILDBUILDING.COM
29
D:\Jacob Rice\Time to Shine\Goose Creek\Plan Set\Plan Set for ARB_8.2.21.dwgAug 02, 2021 - 4:15pmPrinted By:Alden
803.760.3437
14 CALENDAR CT.
COLUMBIA, SC 29206
NOTE: THIS SCALE APPLIES
FOR SHEETS ONLY24"x36"
1 INCH = FT
GRAPHIC SCALE
020' 10' 20'
20
SITE VICINITY MAP - 1"=1500'
539 ST JAMES AVE.
GOOSE CREEK, SC 29445
OLD MT. HOLLY RD
ST. JAMES AVE
PROJECT SITE
MAP & DEMOLITION NOTES:
1. ALL EXISTING BOUNDARY INFORMATION PROVIDED BY PARKER LAND SURVEYING, LLC (SEALED BY
RICHARD A. ALDRIDGE ON MAY 12, 2021) & TOPOGRAPHY INFORMATION PROVIDED BY SURVEYING &
MAPPING, LLC (SAM) (SEALED BY DON WILLSON ON JULY 30, 2021).
2. TRANSFER OF SITE BENCHMARK(S) IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR AND
SHALL ONLY BE COMPLETED BY A SURVEYOR LICENSED/REGISTERED IN THE STATE IN WHICH THE
PROJECT IS LOCATED.
3. THE CONTRACTOR IS RESPONSIBLE FOR FIELD VERIFICATION OF EXISTING BENCHMARK(S) PRIOR
TO ANY CONSTRUCTION AND SHALL REPORT ANY DISCREPANCIES IMMEDIATELY TO THE ENGINEER.
FIELD VERIFICATION CAN BE ACCOMPLISHED BY CHECKING A MINIMUM OF TWO FIXED OBJECTS
DISPLAYED ON THE SURVEY (i.e. MANHOLE RIM, STORM GRATE, PIPE INVERTS, ETC.).
4. THE CONTRACTOR SHALL FIELD VERIFY ALL ITEMS TO BE DEMOLISHED & REMOVED FROM THE SITE.
THE VERIFICATION PROCESS SHALL INCLUDE VISITING & WALKING THE SITE WITH THE OWNER AND
THE ENGINEER. ALL ITEMS REQUIRING DEMOLITION/REMOVAL, WHETHER SHOWN ON THIS PLAN OR
NOT, SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR.
5. PRIOR TO THE COMMENCEMENT OF CLEARING, THE CONTRACTOR SHALL WALK THE SITE WITH THE
OWNER & ENGINEER TO IDENTIFY TREES AND/OR VEGETATION TO REMAIN. PROTECTION OF
IDENTIFIED TREES AND/OR VEGETATION SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR.
6. ALL DEMOLISHED ITEMS/MATERIALS OR ANY ITEMS THAT ARE NOT SALVAGED SHALL BE REMOVED
FROM THE PROJECT SITE & DISPOSED OF IN ACCORDANCE WITH APPLICABLE CODES.
7. THERE SHALL BE NO BURNING ON-SITE.
8. EROSION & SEDIMENT CONTROL DEVICES MUST BE IN PLACE PRIOR TO DEMOLITION. REFER TO
THE CONSTRUCTION SEQUENCE ON GENERAL NOTES SHEET C-002. FIRST, CLEARING, GRUBBING, &
DEMOLITION SHALL BE LIMITED TO INSTALL PERIMETER CONTROL BMPs (INCLUDES SILT FENCE,
INLET PROTECTION FOR EXISTING STRUCTURES, & CONSTRUCTION ENTRANCE(s)).
9. IF ANY HAZARDOUS MATERIAL IS ENCOUNTERED DURING DEMOLITION, THE CONTRACTOR SHALL
COORDINATE WITH THE OWNER & APPROPRIATE AGENCIES FOR PROPER REMOVAL & DISPOSAL.
10. ANY TREES TO BE CLEARED SHALL BE REMOVED OF STUMPS AND ROOT SYSTEM ENTIRELY.
11.IF ENCOUNTERED, WELLS & SEPTIC TANKS SHALL BE ACCURATELY LOCATED BY THE CONTRACTOR &
THE SURROUNDING AREA SHALL BE BARRICADED & GRADES SHALL BE MAINTAINED IN THE AREA
SUCH THAT SURFACE RUNOFF CANNOT ENTER THE OPENING. THE CONTRACTOR SHALL NOTIFY THE
THE ENGINEER & OWNER IMMEDIATELY.
12. APPLICABLE SCDOT PERMITS SHALL BE OBTAINED BEFORE PERFORMING ANY WORK IN SCDOT R/W.
13. PROPOSED WORK ON ADJACENT PROPERTIES SHALL NOT TAKE PLACE PRIOR TO
PERMISSION/TEMPORARY CONSTRUCTION EASEMENTS ARE OBTAINED.
14. SIDEWALK, CURB, AND GUTTER TO BE REMOVED AND REPLACED FROM JOINT TO JOINT.
15. CONTRACTOR TO SAW CUT, WHERE APPLICABLE, FOR SMOOTH JOINTS. JOINTS SHALL NOT BE
ALIGNED WITH WHEEL PATH.
16. THE CONTRACTOR SHALL DEMOLISH EXISTING BUILDING, CANOPIES, ACCESSORY STURTURES,
FOUNDATIONS, ATTACHED UTILITIES, ASPHALT, & CURB & GUTTER, ETC. INSIDE THE DEMOLITION
LIMITS ENTIRELY, EXCEPT WHERE SHOWN. REFERENCE SHEET C-401 FOR UTILITIES TO REMAIN
FULLY OPERATIONAL.
17. THE CONTRACTOR SHALL COORDINATE WITH THE APPLICABLE UTILITIES FOR THE REMOVAL /
RELOCATION OF EXISTING UTILITIES (UNDERGROUND & OVERHEAD).
MAP & DEMOLITION NOTES:
30
20' BUILDINGSETBACK LINE
FLAG POLE
D:\Jacob Rice\Time to Shine\Goose Creek\Plan Set\Plan Set for ARB_8.2.21.dwgAug 02, 2021 - 4:33pmPrinted By:Alden
803.760.3437
14 CALENDAR CT.
COLUMBIA, SC 29206
NOTE: THIS SCALE APPLIES
FOR SHEETS ONLY24"x36"
1 INCH = FT
GRAPHIC SCALE
020' 10' 20'
20
LOT SUMMARY:
ADDRESS: 539 ST JAMES AVE., GOOSE CREEK, SC 29445
TMS #: 234-00-00-153
TOTAL PROJECT SITE AREA: ±1.26 ACRES
ZONING: GENERAL COMMERCIAL
- EXISTING LAND USE: VACANT COMMERCIAL
- PROPOSED USE: AUTOMOBILE SERVICE STATION (AUTOMATED
CAR WASH)
LOT REQUIREMENTS:
- SETBACKS: FRONT - 20', REAR - 20', & SIDE - 10'
- BUFFER YARDS: NONE
- STREET YARD: 10'
- MAX IMPERVIOUS SURFACE RATIO: 80%
PROPOSED BUILDING:
- BUILDING AREA (GFA): ±5,200 SF
REQUIRED PARKING: 1 SPACE PER 250 SF
PROPOSED PARKING:
-TOTAL PROPOSED PARKING: 35 SPACES
(30) STANDARD VACUUM SPACE
(1) VAN ACCESSIBLE HANDICAP VACUUM SPACE
(4) STANDARD SPACE (EMPLOYEE PARKING)
LEGEND
CONCRETE PAVEMENT
LANDSCAPED AREA
(SEE LANDSCAPE PLAN)
CONCRETE SIDEWALK
VACUUM MOTOR / EQUIP.
VACUUM STATION
VAC
1. SEE GENERAL NOTES, SHEET C-002.
2. ALL DIMENSIONS ARE MEASURED FROM FACE OF CURB TO FACE OF CURB UNLESS OTHERWISE NOTED.
3. ALL CURB RADII MEASURED FROM FACE OF CURB TO FACE OF CURB UNLESS OTHERWISE SHOWN.
4. ALL PROPOSED CURB & GUTTER TO BE 18" BARRIER TYPE UNLESS SHOWN OTHERWISE.
5. ALL SIDEWALKS, STRIPING, & SIGNAGE TO BE ADA & MUTCD COMPLIANT.
6. THE CONTRACTOR SHALL FURNISH & INSTALL "HANDICAP PARKING" SIGNS WITH IDENTIFYING HANDICAPPED
SYMBOL AT ALL HANDICAPPED PARKING STALLS. INCLUDE VAN ACCESSIBLE SIGN, WHERE APPLICABLE
(SEE DETAILS).
7. THE CONTRACTOR SHALL FURNISH & INSTALL ALL SIGNS SHOWN IN ACCORDANCE WITH SCDOT & MUTCD
SPECIFICATIONS.
8. ALL PARKING LOT STRIPING TO BE 4" WIDE TRAFFIC MARKING PAINT UNLESS OTHERWISE NOTED. ALL
PAINT SHALL BE APPLIED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS.
9. ITEMS TO BE PAINTED WHITE INCLUDE BUT NOT LIMITED TO: TRAFFIC ARROWS, STOP BARS, PEDESTRIAN
CROSSINGS, NON ADA AISLES, & NON ADA PARKING STALLS.
10.ITEMS TO BE PAINTED YELLOW INCLUDE BUT NOT LIMITED TO: DOUBLE YELLOW, ROAD STRIPING, ETC.
11.ITEMS TO BE PAINTED BLUE INCLUDE BUT NOT LIMITED TO: HANDICAP PARKING STALLS, HANDICAP
SYMBOLS, HANDICAP ACCESS AISLES, & ADA CROSSING AREAS.
12. CONTRACTOR TO REMOVE AND REPLACE DAMAGED SIDEWALK OR CURB & GUTTER ALONG PROPERTY FRONTAGE
AS NECESSARY.
13. SIDEWALK AND CURB AND GUTTER TO BE REMOVED AND REPLACED FROM JOINT TO JOINT.
14.IN PRESENCE OF SIDEWALK OR OTHER ADA PATHWAYS, ACCESS(ES) TO PROVIDE A MINIMUM OF 3' WIDE
PEDESTRIAN PATH OF NO GREATER CROSS SLOPE THAN 2%.
15. REFER TO THE LANDSCAPE PLAN FOR PROPOSED PLANTINGS IN BUFFERYARDS, LANDSCAPE ISLANDS, ETC.
16. CONTRACTOR TO COORDINATE LOCATION OF BOLLARDS WITH THE OWNER/DEVELOPER.
17. CONTRACTOR TO REFER TO ARCHITECTURAL PLANS FOR SITE LIGHTING.
18. CONTRACTOR TO REFER TO OWNER'S EQUIPMENT PLAN & COORDINATE LOCATION OF EQUIPMENT WITH THE
OWNER/DEVELOPER.
SITE NOTES:
31
20' BUILDINGSETBACK LINE
FLAG POLE
D:\Jacob Rice\Time to Shine\Goose Creek\Plan Set\Plan Set for ARB_8.2.21.dwgAug 02, 2021 - 4:36pmPrinted By:Alden
803.760.3437
14 CALENDAR CT.
COLUMBIA, SC 29206
NOTE: THIS SCALE APPLIES
FOR SHEETS ONLY24"x36"
1 INCH = FT
GRAPHIC SCALE
020' 10' 20'
20
LOT SUMMARY:
ADDRESS: 539 ST JAMES AVE., GOOSE CREEK, SC 29445
TMS #: 234-00-00-153
TOTAL PROJECT SITE AREA: ±1.26 ACRES
ZONING: GENERAL COMMERCIAL
- EXISTING LAND USE: VACANT COMMERCIAL
- PROPOSED USE: AUTOMOBILE SERVICE STATION (AUTOMATED
CAR WASH)
LOT REQUIREMENTS:
- SETBACKS: FRONT - 20', REAR - 20', & SIDE - 10'
- BUFFER YARDS: NONE
- STREET YARD: 10'
- MAX IMPERVIOUS SURFACE RATIO: 80%
PROPOSED BUILDING:
- BUILDING AREA (GFA): ±5,200 SF
REQUIRED PARKING: 1 SPACE PER 250 SF
PROPOSED PARKING:
-TOTAL PROPOSED PARKING: 35 SPACES
(30) STANDARD VACUUM SPACE
(1) VAN ACCESSIBLE HANDICAP VACUUM SPACE
(4) STANDARD SPACE (EMPLOYEE PARKING)
LEGEND
CONCRETE PAVEMENT
LANDSCAPED AREA
(SEE LANDSCAPE PLAN)
CONCRETE SIDEWALK
VACUUM MOTOR / EQUIP.
VACUUM STATION
VAC
32
VAC
VAC
D:\Jacob Rice\Time to Shine\Goose Creek\Plan Set\Plan Set for ARB_8.2.21.dwgAug 03, 2021 - 5:52pmPrinted By:Alden
803.760.3437
14 CALENDAR CT.
COLUMBIA, SC 29206
NOTE: THIS SCALE APPLIES
FOR SHEETS ONLY24"x36"
1 INCH = FT
GRAPHIC SCALE
020' 10' 20'
20
PLANT SCHEDULE
BOTANICAL NAME
LIVE OAK
OR APPROVED EQUAL
AMERICAN HOLLY
OR APPROVED EQUAL
SABAL PALM
OR APPROVED EQUAL
LITTLE GEM MAGNOLIA
OR APPROVED EQUAL
INDIAN HAWTHORNE
OR APPROVED EQUAL
PODACARPUS
OR APPROVED EQUAL
LIGUSTRUM
OR APPROVED EQUAL
SYMBOL CAL SIZE QTY
2.5"
1"
1.5"
1.5"
3 GAL.
3 GAL.
3 GAL.
8-10' HT
6' HT
6' HT
6' HT
5
5
4
6
11
36
49
1. THE CONTRACTOR IS RESPONSIBLE FOR HIS OR HER OWN
QUANTITIES. IF THERE IS A CONFLICT BETWEEN QUANTITIES
AND SPACING, SPACING SHALL PREVAIL.
2. ALL TREES AND SHRUBS SHALL BE MULCHED (2-3" IN DEPTH)
WITHIN TWO DAYS AFTER PLANTING, MULCH SHALL COVER THE
AREA OF THE PLANTING PIT, BED, OR SAUCER, AROUND EACH
PLANT.
3. ANY AREA DISTURBED DURING CONSTRUCTION NOT COVERED BY
NEW CONSTRUCTION, SODDING, AND OR PLANT BEDS SHALL BE
PERMANENTLY GRASSED. AS SPECIFIED AT NO ADDITIONAL COST
TO THE OWNER.
4. ALL PLANTS SHALL MEET THE STANDARDS AND SPECIFICATIONS
OF THE AMERICAN STANDARD FOR NURSERY STOCK, LATEST
EDITION.
5. ALL PLANTINGS SHALL IN BE ACCORDANCE WITH THE LATEST
CITY OF GOOSE CREEK LANDSCAPE ORDINANCES.
LANDSCAPE NOTES:
LEGEND
CONCRETE PAVEMENT
SOD / INTERNAL LANDSCAPING
CONCRETE SIDEWALK
VACUUM MOTOR / EQUIP.
VACUUM STATION
VAC
LANDSCAPE REQUIREMENTS
REQUIRED
STREET YARD REQUIREMENTS
STREET FRONTAGE TREES 2 CANOPY TREES OF A MINIMUM
OF 2.5" CALIPER (8-10'HT.)
REQUIRED FOR EACH 100 LF OF
STREET FRONTAGE
BUFFER YARD REQUIREMENTS
BUFFER YARD PLANTINGS NONE REQUIRED (ADJACENT USE(S)
IS COMMERCIAL / GC)
OTHER REQUIREMENTS
LANDSCAPE AREA SHALL BE 12% OF THE TOTAL AVAILABLE AREA.
10% OF PLANTINGS SHALL BE TREES OR 12 TREES PER ACRE,
WHICHEVER IS GREATER
LANDSCAPED ISLANDS SHALL BE PROVIDED FOR EVERY 10 SPACES.
1 CANOPY & 2 SHRUBS SHALL BE PLANTED IN ISLANDS
SHRUBS MATURING TO 2' MIN. HEIGHT SHALL BE PLANTED AT 5' ON
CENTER FOR THE ENTIRE LENGTH OF PROPOSED BUILDING FACADE
FACING THE RoW
33
A1
FLOOR PLAN
1/8" = 1'-0"
n
Fax
Phone
faldesco@gmail.com
4622 Chambliss Avenue
K
copyright 2021
584
584
865
865
le, T N
.
.
vixo l
©
97
.
.
3 9
3139
7868
1
FALCONNIER
C1
OFFICE AREA DETAIL
1/8" = 1'-0"
N
05 4 810
FEET
34
A1
SOUTH (OFFICE) ELEVATION
1/8" = 1'-0"
n
Fax
Phone
faldesco@gmail.com
4622 Chambliss Avenue
K
copyright 2021
584
584
865
865
le, T N
.
.
vixo l
©
97
.
.
3 9
3139
7868
1
FALCONNIER
A5
WEST (EXIT) ELEVATION
1/8" = 1'-0"
B1
EAST (ENTRANCE) ELEV.
1/8" = 1'-0" B2
NORTH (TUNNEL) ELEVATION
1/8" = 1'-0"
EXTERIOR FINISHES
05 4 810
FEET
35
A1
ENTRY ELEVATION
1/8" = 1'-0"
n
Fax
Phone
faldesco@gmail.com
4622 Chambliss Avenue
K
copyright 2021
584
584
865
865
le, T N
.
.
vixo l
©
97
.
.
3 9
3139
7868
1
FALCONNIER
05 4 810
FEET
B1
EXIT ELEVATION
1/8" = 1'-0"
36
A1
OFFICE ELEVATION
1/8" = 1'-0"
n
Fax
Phone
faldesco@gmail.com
4622 Chambliss Avenue
K
copyright 2021
584
584
865
865
le, T N
.
.
vixo l
©
97
.
.
3 9
3139
7868
1
FALCONNIER
05 4 810
FEET
B1
TUNNEL ELEVATION
1/8" = 1'-0"
37
A1
SITE PERSPECTIVE
NO SCALE
n
Fax
Phone
faldesco@gmail.com
4622 Chambliss Avenue
K
copyright 2021
584
584
865
865
le, T N
.
.
vixo l
©
97
.
.
3 9
3139
7868
1
FALCONNIER
38
A1
SITE PERSPECTIVE
NO SCALE
n
Fax
Phone
faldesco@gmail.com
4622 Chambliss Avenue
K
copyright 2021
584
584
865
865
le, T N
.
.
vixo l
©
97
.
.
3 9
3139
7868
1
FALCONNIER
39
A1
BUILDING PERSPECTIVE
NO SCALE
n
Fax
Phone
faldesco@gmail.com
4622 Chambliss Avenue
K
copyright 2021
584
584
865
865
le, T N
.
.
vixo l
©
97
.
.
3 9
3139
7868
1
FALCONNIER
C1
BUILDING PERSPECTIVE
NO SCALE
A4
BUILDING PERSPECTIVE
NO SCALE
40
Design Memorandum
TO: Architectural Review Board
FROM: Mark Brodeur, Planning and Zoning
Director
DATE: August 16, 2021
SUBJECT: Time to Shine Car Wash
Dear ARB Members:
I’d like to share some comments on this project. I am sharing because of the prominent corner of this
proposal.
The Site Plan
This proposed Site Pan for the project has several admirable aspects that mitigate the usual issues
associated with vehicular flow. Here is what is positive about the site plan.
The building mass is located at the intersection.
Vehicular connection to Plantation North shopping center.
A deep entry access to payment kiosk permits car stacking
A significant vehicle queue into wash car wash structure
Provided parking spaces are extra-wide to accommodate open door vacuuming
Plenty of parking spaces for individual car vacuuming
A drive thru “escape” lane
Of course, there are always potential improvements that could improve on-site vehicular flow. I offer
the following suggested modifications for ARB consideration.
Customer spaces would be easier to access if they were diagonal. Seniors have a more difficult
time pulling into perpendicular parking spaces.
Coupled with diagonal spaces, the proposed two-way circulation would prove more problematic
than a simple one-way flow. Subsequently, the aisle dimensions could be reduced and drivers
only have to look in one direction before pulling out of the space.
Four employee/customer spaces may not be sufficient.
Place brick pilasters along the St. James and Plantation North frontages (see images below).
An alternate location for the dumpster should be considered or an upgraded design that is less
utilitarian in nature.
The Architecture
The proposed building architecture needs considerable upgrading due to the prominence of the
commercial intersection along St. James Avenue. Staff understands that car washes are mostly
utilitarian, and that form follows function. However, that does not mean that Goose Creek needs to
settle for uninspiring commercial design on an important corner.
41
Staff suggests that the ARB instruct the architect to return with another design proposal.
Staff has reviewed three (3) other “Time to Shine” car washes in the Low Country and suggests that
Goose Creek may not be receiving a very compelling design solution for this prominent location.
Without delving into unnecessary negative commentary, the Planning Director suggests that the ARB
instruct the architect to return with a design that is more in keeping with the current “Time to Shine” on
Savannah Highway shown below. There are several reasons to do this.
Using an existing car wash design reduces costs of a total redesign.
A 2-Story building mass is preferred on this corner. The current proposal is a one-story with a
tower element.
The design is fresh, clean and interesting. The proposed architecture is too gimmicky with its
blue roofs and red trimmed shade canopies. This all needs to be toned-down a bit.
The brick accents compliment architecture on other corners.
42
TIME TO SHINE CARWASH – SAVANNAH HWY – STREET VIEW GOOGLE MAPS
43
TIME TO SHINE CAR WASH – S
TIME TO SHINE CARWASH – SAVANNAH HWY. – STREET VIEW GOOGLE MAPS
44
TIME TO SHINE CARWAS – SAM RITTENBURG – STREET VIEW GOOGLE MAPS
45
TIME TO SHINE CARWASH – SAM RITTENBURG – REAR STREET VIEW GOOGLE MAPS
46
47
48
49
50
044270
75.00
08/02/2021
21
8
03015
250.80
250.80
238990
75.0008/02/2021
Property in Goose Creek
Carnes Development Zone:
Town Center Zone
~106’
Right of way
Curb & Gutter
103” = 8.6’
296” = 24.67’
Allowable Signage:
As building is located 106’ from property line (see next page), the business
is allowed 1.5 x frontage of 24.67 = 37 sq feet of signage.
Embossed and painted. Cap over face
Internal illumination. Quantity 1 Proposed Roof-Mounted Sign:
Internally illuminated logobox cabinet
82.5” wide x 60”
tall Sign Cabinet
Square Footage:
34.4
2424 N. Main Street; Summerville, SC 29486
82.5”
60”
103” = 8.6’
296” = 24.67’
Proposed Building Sign:
Roof-Mounted
Proposed Bracket (Engineer to
provide specifications)
12’-3”
Approx 24”
Power Must be provided by others
for roof-mounted sign. 120V on
dedicated 20 amp breaker.
Recommend electrician tying into
timeclock.
2424 N. Main Street; Summerville, SC 29486
5” thick sign cabinet
60” tall cabinet
Proposed Bracket as specified by enginner
FASTENERS AS
SPECIFIED BY
ENGINEER FOR
ATTACHMENT TO
ROOF.
Power Must be provided by others
for roof-mounted sign. 120V on
dedicated 20 amp breaker.
Recommend electrician tying into
timeclock.
Proposed Roof-Mounted Sign:
Bracket and Attachment Details
RETAINER
FASTENERS AS SPECIFIED BY
ENGINEER FOR ATTACHMENT
TO BRACKET
BRACKET (AS SPECIFIED BY
ENGINEER)
Roof-Mounted Sign: Electrical Detail
Overall Sq Footage: 108” x 60” = 45 sq feet
Overall Sign Height: 2’ base + 5’ sign = 7’ tall
Proposed Roadside Sign
Proposed Monument – Construction Detail
Double-Sided cabinet (12’ deep)
Embossed Acrylic Faces
Internally illuminated LED lighting
Pole skirt
Single-pole mounted (saddle mount)
steel square tube center post
Base of cabinet to be black
Foundation Details
(See Engineered
Drawing)
steel square tube
center post (see
engineered
drawing for
details)
3/8” through bolt
to attach sign to
steel post
Saddle Mounting
Detail
12” deep
Right of way
Curb & Gutter
Roadside Sign Location (Option A: Preferred Location)
A
6’
10’
10’
Power Must be provided for
monument sign. 120V on
dedicated 20 amp breaker.
Recommend electrician tying into
timeclock. Recommend leaving
plastic conduit out of ground about
1.5’ with about 6’ of wire coiled up
that we can run up through sign
cabinet to power sign.
12.5’ from street curb