RecordWell Data

Historic District Review Board — Agenda Packet

City of Beaufort · Beaufort County · Historic District Review Board · meeting of Oct 14, 2026 · Agenda packets

Open the original document More from City of Beaufort

Text

Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.

1 M EETING AGENDA CITY OF BEAUFORT - HISTORIC DISTRICT REVIEW BOARD Wednesday, October 14, 2026, at 2:00 pm City Hall, Council Chambers, 2nd Floor – 1911 Boundary Street, Beaufort, SC Please click the link below to access the Zoom meeting: https://us02web.zoom.us/j/84548359275?pwd=gffRaUj9broGCjWVYYn4aOdz0RreHf.1 Password: 516372 Meeting ID: 845 4835 9275 Call in Phone #: +1 929 205 6099 STATEMENT OF MEDIA NOTIFICATION: “In accordance with South Carolina Code of Laws, 1976, Section 30-4-80(d), as amended, all local media were duly notified of the time, date, place, and agenda of this meeting.” Please note, this meeting will also be live streamed via Zoom. Anybody interested can watch this meeting on the City's YouTube page: “City Beaufort SC”. Note: A project will not be reviewed if the applicant or representative is not present at the meeting. I. Call to Order II. Review of Minutes • August 12, 2026 - Meeting III. Applications A. 1 010 Boundary Street/1112 Charles Street, PIN: R120 004 000 0071-/0072-/0073 0000: Construction of eight (8) new townhomes (two 4-unit buildings) & four (4) duplexes (two 2- unit buildings; infill development) Applicant(s): Ben and Christine Wiley The applicants are requesting final approval for new construction/infill-development of two 4-unit townhome buildings (attached) fronting Boundary Street, and two duplex (2-unit) buildings in the rear which would be accessible from both Charles and Newcastle Streets. IV. Adjournment 1 Historic District Review Board Meeting Minutes – August 12, 2026 CALL TO ORDER 1:00 A meeting of the Historic District Review Board was called to order by Mike Sutton, Chairman. The meeting was held in-person in Council Chambers on Wednesday, August 12, 2026 at 2:00 PM. The meeting was broadcasted via zoom and live-streamed on YouTube. You can view this meeting at the City’s page; City of Beaufort Government. ATTENDEES Members in attendance: Mike Sutton (Chair), Kim Petrella, Richard Drake, and Rita Wilson. Member Absent: Eric Berman, (Vice-Chair). Staff in attendance: Curt Freese, Community Development Director, Christopher Klement, Community Development Planner III, Nick Navia, Community Development Planner II, Julie Bachety, Administrative Assistant II, as well as Maxwell Larkby, Community Development Planning Intern, and Meadors Architects (online). REVIEW OF THE JULY 8, 2026 MINUTES 1:11 Ms. Wilson noted under Attendees, Grady Woods name needs to be replaced with Richard Drake. Motion: Ms. Petrella made a motion to accept the minutes. Mr. Drake seconded the motion. The motion passed unanimously. All Historic District Review Board Meeting minutes are recorded and can be found on the City’s website at http://www.cityofbeaufort.org/AgendaCenter. CONSENT AGENDA ITEM 2:07 A. 1411 North Street, PIN: R120 004 000 0663 0000: Approval of Bailey Bill Tax Credit application for completed rehabilitation of historically contributing dwelling (Emil E. Lengnick House) Applicant: Rossdhu Properties, LLC c/o Mr. Steve Goggans, Owner The applicant is requesting approval for a 10-year property tax freeze for previously completed historic renovation work to the historically contributing dwelling, based on the local Bailey Bill Act. Mr. Sutton recused himself from this project. Ms. Petrella, Board Secretary, took over as Chair since Eric Berman, Vie-Chair was absent from the meeting. 2 The Board were all in favor of the changes and the updates. APPLICATIONS 13:30 B. 910 Harrington Street, PIN: R120 004 000 0256 0000: Change-after request for exterior siding material and replacement windows for renovation/upfit of contributing dwelling Applicant: Carlton Linnen, Owner Mr. Sutton returned to the meeting at this point. Ms. Petrella relinquished being Chair. The applicant is requesting change of the previously approved exterior materials, including installation of Hardie Plank lap-siding (instead of wood siding) and installation of appropriate replacement windows (instead of original window repair). The original Certificate of Appropriateness letter was issued June 1, 2026. Nick Navia presented his staff report. Public Comment: Lise Sundrla, Historic Beaufort Foundation (HBF) Director, stated we are in support of the application. Public comment closed. Motion: Ms. Petrella made a motion to approve the application as presented. Mr. Drake seconded the motion. The motion passed unanimously. C. 1010 Boundary Street/1112 Charles Street, PIN: R120 004 000 0071-/0072- 31:14 /0073 0000: Construction of eight (8) new townhomes (two 4-unit buildings) & four (4) duplexes (two 2-unit buildings; infill development) Applicant: MediaLink LLC (Ben and Christine Wiley), Applicant The applicant is requesting conceptual/preliminary approval for new construction/infill-development of two 4-unit townhome buildings fronting Boundary Street, and two duplex (2-unit) buildings in the rear which would be accessible from both Charles and Newcastle Streets. Ms. Wilson recused herself from this project. Christopher Klement presented his staff report. Lise Sundrla, HBF Director, commended the applicants on their improvements of the design. Ms. Sundrla stated HBF is in agreement with staff’s comments and recommendations. Public comment closed. 3 Motion: Mr. Drake made a motion to approve the application conceptually. Ms. Petrella seconded the motion. The motion passed unanimously. Ms. Wilson returned to the meeting at this time. MISCELLANEOUS DISCUSSION 1:24:20 The Board discussed possible changes to the application packet and process associated with the local Bailey Bill Tax Abatement Program. Staff suggested having a Board Training workshop in September to go over possible amendments to the 2022 Beaufort Preservation Manual, together with the Appendix on the Northwest Quadrant Design Manual in presenting and reviewing more alternative material selections for historic rehabilitation that could be recommended and made permissible. ADJOURNMENT 1:36:28 Mr. Drake made a motion to adjourn which was seconded by Ms. Petrella. The meeting ended at 3:36 pm. STAFF REPORT: HISTORIC DISTRICT REVIEW BOARD (HDRB) 1010 BOUNDARY STREET / CHARLES ST. / NEWCASTLE ST. DATE: October 14, 2026 1 GENERAL INFORMATION Applicant: MediaLink LLC - Ben and Christine Wiley Site Address / PIN: 1010 Boundary Street / 1112 Charles Street / PIN #’s: R120 004 000 0071 0000; R120 004 000 0072 0000; R120 004 000 0073 0000 Applicant's Request: Applicant is requesting final approval for 12 dwelling units divided between 4 buildings, consisting of: • Two 4-unit attached townhome buildings fronting Boundary Street (8 dwellings), and • Two 2-unit (duplex) buildings in the rear, accessed from Charles/Newcastle Streets (4 dwellings) Current Zoning: T5-URBAN CORRIDOR (T5-UC) Contributing/Neighborhood Currently vacant lots / The Northwest Quadrant neighborhood Flood Zone/Base Flood Flood Zone: X, Elevation: 17 ft – 19 ft (BFE: 13 ft) Overall Lot Size 17,024 Sqft (0.391 acres) [5,566 sqft + 5,766 sqft + 5,692 sqft] ZONING DISTRICT INFORMATION T5-URBAN CORRIDOR (T5-UC) Lot Width at Setback: N/A Minimum Lot Size: N/A Max Lot Coverage: 100% Frontage Build Out 60% min Front Setback – Primary 0 ft min – 15 ft max Side Setback – Primary Corner/Alley: 0 ft – 15 ft Interior: 0 ft Rear Setback – Primary 5 ft min; from alley: 0 ft. Building Height: Primary Structures: 5 stories max; 3.5 stories max in & fronting Historic District Accessory Structures: 2 stories max SURROUNDING ZONING, LAND USE AND REQUIRED BUFFERS Adjacent Zoning Adjacent Land Uses Setbacks for Adjacent Zoning /Buffer required if rezoned North: T5-UC 1211 Newcastle St. - Non- Contributing; Commercial N/A South: T5-UC 1108 Charles St. - Non- Contributing; Commercial N/A East: T5-UC 1107 Charles St. - Non- Contributing; Commercial N/A West: T5-UC 1012 Boundary St. - Non- Contributing; Commercial N/A 2 Background: This project has been presented at two HDRB meetings (1st meeting: June 10th, 2026; 2nd meeting: August 12th, 2026), After changes to the original proposal which included 3 sets of townhouse buildings with 4 units each, the conceptual approval now consists of two 4 -unit townhouse buildings fronting Boundary Street , and two duplex buildings accessed via Charles and Newcastle Streets, for a total of 12 units. The Board had previously decided to table this request based on various concerns, including massing & scaling, building design, lot placement & setbacks as well as existing utilities. After various revisions were made and presented at the project’s second HDRB Meeting on August 12 th, the Board granted conceptual approval, and the applicants are now requesting final approval. Project Timeline: Jan. 2026 Feb. Mar. Apr. May Jun. Jul. Aug. Sep. Oct. Nov. Dec. 5/6: 1st HTRC Meeting 6/10: 1st HDRB Meeting - tabled 7/15: 2nd HTRC Meeting 8/12: 2nd HDRB Meeting 10/14: 3rd HDRB Meeting Summary of the HDRB Meeting (8/12/2026): Applicant: MediaLink, LLC c/o Ben and Christine Wiley The applicant is requesting conceptual/preliminary approval for new construction/infill-development of two 4-unit townhome buildings fronting Boundary Street, and two duplex (2-unit) buildings in the rear which would be accessible from both Charles and Newcastle Streets. Ms. Wilson recused herself from the project. Nick Navia presented his staff report. Public Comment: Lise Sundrla, HBF Director, commended the applicants on their improvements of the design. Ms. Sundrla stated HBF is in agreement with staff’s comments and recommendations. Motion: Mr. Drake made a motion to approve the application conceptually. Ms. Petrella seconded the motion. The motion passed unanimously. Tree Removal Proposed: A few existing Specimen/Landmark trees may be affected by this in-fill development request. Specimen/Landmark tree status and potential mitigation to be assessed during Development Design Review process. Surrounding Area: The subject properties are located along Boundary Street on the northern edge of the Beaufort Historic District and the “Northwest Quadrant” neighborhood. The subject properties are currently vacant. The surrounding area can be 3 characterized as “urban, mixed use”, consisting of both commercial shops and businesses as well as student housing and college-related (USCB) uses nearby. Determination of adequate historic integrity for New Construction, Infill, Additions and Demolition: As per the Beaufort Preservation Manual (Chapter 5) and the Beaufort Development Code (Section 4.7) , the compatibility of new infill construction as well as major renovations within the Beaufort Historic District is determined in consideration with the following principles : 1. Location, 2. Design, 3. Setting, 4. Materials, 5. Workmanship, 6. Feeling and 7. Association. See staff analysis and recommendations below. 1010 Boundary Street – Staff Analysis 1. Current Lots / Lot Consolidation Staff Analysis: • Staff supports the future lot consolidation on the basis that the applicant receives Conceptual/Preliminary Approval and an SCDOT Encroachment Permit for access from Charles Street. 4 1010 Boundary Street – Overview of main changes (staff analysis): 2. Building placements/Lot configuration Inititally presented Site Plan (6-10-2026) 5 Previously presented version of Site Plan (as per 8-12-2026) 6 Latest version of Site Plan (as per 9-22-2026) 7 Staff Analysis of Site Plan changes: • The latest design revision includes separated front porches for the rear duplex buildings, where those were combined before • The previous revision of an increased setback to the adjacent property to the west (“Alpha Graphics”) from formerly 2ft. to now 5ft. 9in. has remained in place • 6ft. separation between the two Townhouse buildings in the middle and a 2ft. setback from Charles St. on the east (no changes). • Boundary Street-fronting Townhouses are served with ground-level 2-car garages in the rear, accessible through an Access Easement that connects with Charles Street on the east and Newcastle Street to the south and west; the rear duplexes will have side-loading garages (no changes). 1010 Boundary Street – Staff Analysis: • Building Elevations [Front elevation, facing Boundary Street - 6-10-2026] 8 [Front elevation, facing Boundary Street as previously submitted on 8-12-2026] Main staff architectural (Meadors) comments: • Windows seem off-centered on wall • Uneven window spacing • Consider flipping units so that each unit has its own entrance • Move downspouts into recesses to give the recesses more purpose • Can the downspout placed so obviously in the middle be removed? 9 10 Side elevations of townhome unit facing Charles Street (left: 6-10- 2026; right: 8-12-2026) Side elevation of townhome unit facing Print Shop (8-12-2026) 11 [Front elevation, facing Boundary Street / Side elevation facing Charles Street – latest submittal as per 9-22-2026] Right: Side elevation of townhome unit facing Print Shop (9-22-2026) Left: Side elevation of unit facing other townhouse building to the east (9-22-2026) 12 Staff Analysis – Boundary Street-facing townhouses: • Comparing design between conceptual approval (8-12-26) and latest submittal (9-22-26):  Formerly combined front porches have been separated with individual roofs now in place   Downspout locations have been moved/recessed  Previous gabled roofline on side elevation facing Charles St. has been replaced with a flat roof pitch (0:12) [see roof plan below]  Eave brackets are now fully contained with cornice  Formerly blank panels below bay windows now include detailing  Prior faux ground floor (garage) windows have been replaced with real windows with shutters Side elevation of unit facing Charles Street to the east (9-22-2026) Roof plan – eastern townhouse building facing Charles St. (9-22-2026) 13 Rear duplexes – Staff Analysis Right: Rear duplex rendering as presented on 8-12-26 Below: Rear duplex – latest submittal per 9-22-26 14 Left: Front elevation – latest submittal; Below: Side elevation with garage (9-22- 26) Left: Rear elevation – latest submittal (9-22-26) 15 Staff Analysis –2-unit (duplex) buildings at the rear of the property: • Comparing design between conceptual approval (8-12-26) and latest submittal (9-22-26):  Formerly combined front porches have been separated with individual roofs now in place  Eave brackets have been fully included in cornice  Screened-in service yards have been moved to the front corner (were placed at rear corner previously)  Ground floor windows at rear elevation are smaller than first- and second-floor window sizes (as per Sec. 4.6.3.C.2.c – specific to T4/T5: “i¡.Facades. should.have.several.window.sizes.with.smaller.ones.above¡.This.is.particularl y.important.when.buildings.rise.more. than.8.stories¡”) 16 4.7.2 Integrity Guidelines (as per Beaufort Development Code) Rationale Present Staff Analysis of Rationale 1. Location: This is the relationship between the property and its historical context. YES  Boundary Street is currently characterized by mixed land-uses (residential & commercial) in a high-density pattern (T5- UC zone). The proposal for townhomes and duplexes complies with the intent for more urbanity along this downtown corridor. 2. Design: This is the combination of elements that create the feeling of a district or structure. These elements include building patterns, streetscapes, site elements, building size, mass and scale, spatial relationships, and specific architectural elements and details. YES  After latest revisions, the applicants have successfully implemented a more coherent, historically compliant building design which includes many typical residential building design aspects of the Beaufort/Savannah/the Lowcountry. 3. Setting: This is the physical environment of a property and should be evaluated on its context as well as on the historical role the property has played and continues to play. Important features include topography, vegetation, man-made features, and relationships between existing structures and their surroundings. YES  The proposal respects the historic integrity and more dense urban land-use mix of the Boundary Street corridor. 4. Materials: These are the physical elements that make up a property or district. YES  Final Design approval with material list provided; staff review of material cutsheets/specs to be done at permitting/review level. 5. Workmanship: This is the physical evidence of the crafts of a particular culture or time period. This particularly applies to rehabilitation projects, but for new infill projects, workmanship of surrounding structures should be considered and respected. YES  Choice for low-maintenance yet high-quality material combinations for walls/siding consisting of Hardi-plank and brick, amongst others, positively contributes to a high workmanship. 6. Feeling: This is the property's expression of the aesthetic or historic sense of a particular period of time. This particularly applies to rehabilitation projects, but for new infill projects, the feeling of surrounding structures should be considered and respected. YES  The proposal will positively add to the urbanity of the Boundary Street corridor while creating more historical building characteristics at the same time. 7. Association: This is the direct link between an important historic event or person and the property. N/A  N/A 17 FINDINGS AND RECOMMENDATIONS Staff recommends PRELIMINARY APPROVAL with the following conditions and recommendations as per the Beaufort Preservation Manual and requirements of the Beaufort Code: Previously stated recommendations not resolved are listed below: 1. Staff has concerns about the brick ledge at the top of the brick veneer and has concerns that this is a “suburban” detail , and not a typical detail found in the historic district . To appear as a traditional masonry base, the veneer should either be thin brick, or the floor framing should be cantilevered to allow the siding and brick face to be aligned on the same plane. 2. The lower roofline and its gutter interferes with several brackets as the roofline travels around the building. These conflicts should be resolved. 3. Windows and doors are still off -center on the front facades . The windows in the great room (1 st floor) and bedroom #1 (2nd floor) should shift to even the spacing. 4. There is still a false window on the right-side elevation. Staff requests the applicant consider adjusting the kitchen layout to accommodate a real window in these locations. 5. The applicant is utilizing low-pitched roofs to lower the scale of the building. The applicant shall provide a cutsheet of the proposed roof material for review. It is recommended that the applicant utilize a metal drip edge at the roof perimeter to transition to the low-sloped roof material. If any of the low sloped roof material is visible from the public right-of-way (street level), then it must be screened behind a parapet wall. Additional Recommendations for Preliminary Approval: 1. The ground floor windows on the duplex’s Charles Street elevation are narrower and shorter than the windows on the floors above. Per Section 4.6.3.C.2.c, “Façades should have several windows sizes with smaller ones above.” This applies to all other elevations with smaller ground floor windows. 2. One of the side elevations for the 4-unit buildings does not have ground floor windows (between units 4 and 5). Even though these facades are internal to the lot, they will still be highly visible from Boundary Street. Staff recommends windows be added in these areas , unless noted otherwise by the Building Official. 3. No details have been provided in this submission. Applicant to provide typical details including window and door head/sill/jamb details, column, decking/trim connections, brick to siding connections, typical eave conditions, etc. 4. Applicant to note that all SDL windows and doors with glass shall have exterior -applied muntins and interior spacer bars. 5. Applicant to clarify the material for the overhead garage doors. Please note that faux wood grain textures are not allowed. 6. Applicant to clarify the main roofing product. The material list notes that the main roofing material will be GAF Timberline, which is an asphalt shingle. However, the main roof is flat, and asphalt shingles cannot be installed on flat roofs. 7. Staff could be supportive of a 5V metal roof over the stoops, but would recommend the applicant consider a standing seam metal roof to reduce the amount of fastener holes in the roof. 8. Applicant to provide cutsheets for both types of exterior lighting. 18 9. Applicant to provide a detail section through the garage door overhang. This appears to have an awkward connection with the cementitious skirtboard above the brick, and no brackets are shown. Staff recommends lowering the height of the overhang, and adding end brackets so that the overhang appears visually supported. The garage door overhangs on the townhouse units appear to connect to one another. Staff recommends each garage door have a separate, visually supported overhang. 10. Staff recommends shifting the left and right side windows on the duplexes to be more properly centered within the façade. This comment also applies to the windows on the rear townhouse façade. PLANTATION MIX GRAVEL DRIVE COVERED PORCH 56 SQ FT ⏍ SVC YARD HEATED FOOTPRINT AREA (UNIT #1) 592 SQ FT ⏍ FOOTPRINT UNIT #2 628 SQ FT ⏍ UNIT #3 628 SQ FT ⏍ PORCH UNIT #4 592 SQ FT ⏍ SVC YARD UNIT #10 598 SQ FT ⏍ UNIT #9 598 SQ FT ⏍ SVC YARD SVC YARD UNIT #12 598 SQ FT ⏍ UNIT #11 598 SQ FT ⏍ SVC YARD SVC YARD SVC YARD PORCH PORCH UNIT #5 592 SQ FT ⏍ SVC YARD UNIT #6 628 SQ FT ⏍ SVC YARD UNIT #7 628 SQ FT ⏍ SVC YARD UNIT #8 592 SQ FT ⏍ PORCHPORCH PORCHPORCH PORCH PORCH SVC YARD ~19'-2 1 8" ~11'-6" ~19'-2 1 8" ~11'-6" xxxxxx x x x x x x x H Y D ~19'-2 1 8" ~11'-6" ~19'-2 1 8" ~11'-6" ~19'-2 1 8" ~11'-6" ~19'-2 1 8" ~11'-6" ~57'-8" 1' 21'-5 1 2" 21'-5 1 2" 1' 2' 20' 1' 22'-5 1 2" 22'-5 1 2" 1' 20' 2' 1ST FLOOR FFL ~10' ABV GARAGE SLAB 5,696 sq. ft. 0.131 acres 5,777 sq. ft. 0.133 acres 5,569 sq. ft. 0.128 acres R120 004 000 0071 0000 R120 004 000 0072 0000 R120 004 000 0073 0000 RB(O) CALC. PT. EXISTING20' ACCESS EASEMENT P P P P P P SIDEWALK EXISTING 15' ACCESS EASEMENT DIANNE RUSHING BR2 INVESTMENTS LLC JOE SINGLETON 54"LO CM(O) GAS METER BUILDING GRAVEL DRIVEWAY RB(O) GAS VALVE W.METER 10"PAL 12"PAL 17"MAG W.METER 10"PAL TRAF. CONTROL FIRE HUDRANT STORM DRAIN CLUSTER BERRY TREE 36" PECAN 14"PAL 15"PAL 22 LA 42 CHESNUT OAK RB(O) SIDEWALK LIGHT POST BENCHMARK PK NAIL ELEV. 19.16 16"PAL CM(O) CM(O) CM(O) 19.78 18.70 19.28 19.43 19.12 19.21 19.30 18.87 18.98 17.78 17.60 17.6817.82 17.66 17.71 17.7418.1218.0518.37 18.62 19.09 19.74 19.69 19.47 19.50 19.40 19.55 19.73 19.6019.47 19.51 19.38 19.54 19.36 19.34 19.20 19.18 18.44 N 220568.66 N 220722.20 E 2100717.79 NEWCASTLE STREET 60' R\W CHARLES STREET 58' R\W BOUNDARY STREET R\W VARIES EXISTING 20' ACCESS EASEMENT ADJ BUILDING ADJ BUILDING 7' ~5'-9" 22' 23'-5 1 2" 23'-5 1 2" 22' 6' 23' 22'-5 1 2" 22'-5 1 2" 23' 2' 34'30'23'~23' ~5'-10" ~5'-9" ~5'-3" 26' 38'-5" 26' ~2' 8' SHEET 9/22/2026 OVER SVC YARD ~19'-2 1 8" ~19'-2 1 8" SQUARE FOOTAGE FIRST FLOOR 592 SQFT SECOND FLOOR 520 SQFT PORCHES (SCREENED) 56 SQFT AREA OF ADDITION 628 SQFT AREA OF ADDITION 598 SQFT AREA OF ADDITION 592 SQFT AREA OF ADDITION 302 SQFT AREA OF ADDITION 160 SQFT AREA OF ADDITION 64 SQFT 19.09 PRINT SHOP 1st FLR FFL see SITE PLAN GARAGE SLAB FFL see SITE PLAN 9'-1 1 2" 1'-0 3 4" 10'-1 1 8" 1'-0 3 4" 9'-1 1 8" 1' 35'-6" 8'-2" 8' 6' 6' 3'-6" 3'-6" 6'-3" 6'-2 1 2" 8" 2'-10" 2'-10" 8" 4' 8" 2'-10" 2'-10" 8" 6'-2 1 2" 6'-3" TOP of RIDGE 2nd FLR CLG 1st FLR CLG 2nd FLR (12" TRUSS) WIN HDR HGT WIN HDR HGT 1st FLR (12" TRUSS) cLcL 54" DINING TV 60" 2' 36' 8'2'24' 8' 8' 87'-11" 18' 26'-5 1 2" 7' 532 SQ FT LIVING AREA DINING ENTRY GREAT ROOMKITCHEN COVERED PORCH COVERED PORCH GMC YUKON BMW 3 SERIES 23' 66 SQ FT GARAGE SLAB ~9' CLG 4" TURNDOWN CONC. SLAB (see ENGINEERING) o/ VAPOR BARRIER SLOPE THRU OPENING *USE KEYWAY ONLY - NO SAW CUTS* EPOXY FINISH STREET VESTIBULE STREET ENTRY LIVING AREA QUEEN 30"x19" DRESSER KING 11'-0" X 12'-7" 592 SQ FT 8'-8" X 12'-1" LIVING AREA BEDROOM #2 CHASE BEDROOM #1 BATH #2 BATH #1 BRIDGEWATER CONSULTING LLC BEAUFORT, SOUTH CAROLINA nschoen@homesbybridgewater.com (843) 422-7778 HOMEOWNER SIGNATURE & DATE OF ACCEPTANCE REVISION DATE BOUNDARY STREET TOWNHOMES #1 TO #4 RESIDENCE 1010 BOUNDARY STREET BEAUFORT, SOUTH CAROLINA FLOOR OVERVIEW SCALE 3/16 = 1' - 0" *THIS IS A CONCEPT ONLY, NOT MEANT AS CONSTRUCTION DRAWINGS PLANTATION MIX GRAVEL DRIVE COVERED PORCH 56 SQ FT ⏍ SVC YARD HEATED FOOTPRINT AREA (UNIT #1) 592 SQ FT ⏍ FOOTPRINT UNIT #2 628 SQ FT ⏍ UNIT #3 628 SQ FT ⏍ PORCH UNIT #4 592 SQ FT ⏍ SVC YARD UNIT #10 598 SQ FT ⏍ UNIT #9 598 SQ FT ⏍ SVC YARD SVC YARD UNIT #12 598 SQ FT ⏍ UNIT #11 598 SQ FT ⏍ SVC YARD SVC YARD SVC YARD PORCH PORCH UNIT #5 592 SQ FT ⏍ SVC YARD UNIT #6 628 SQ FT ⏍ SVC YARD UNIT #7 628 SQ FT ⏍ SVC YARD UNIT #8 592 SQ FT ⏍ PORCH PORCH PORCHPORCH PORCH PORCH SVC YARD ~19'-2 1 8" ~11'-6" ~19'-2 1 8" ~11'-6" xxxxxx x x x x x x x H Y D ~19'-2 1 8" ~11'-6" ~19'-2 1 8" ~11'-6" ~19'-2 1 8" ~11'-6" ~19'-2 1 8" ~11'-6" ~57'-8" 1' 21'-5 1 2" 21'-5 1 2" 1' 2' 20' 1' 22'-5 1 2" 22'-5 1 2" 1' 20' 2' 1ST FLOOR FFL ~10' ABV GARAGE SLAB 5,696 sq. ft. 0.131 acres 5,777 sq. ft. 0.133 acres 5,569 sq. ft. 0.128 acres R120 004 000 0071 0000 R120 004 000 0072 0000 R120 004 000 0073 0000 RB(O) CALC. PT. EXISTING 20' ACCESS EASEMENT P P P P P P SIDEWALK EXISTING 15' ACCESS EASEMENT DIANNE RUSHING BR2 INVESTMENTS LLC JOE SINGLETON 54"LO CM(O) GAS METER BUILDING GRAVEL DRIVEWAY RB(O) GAS VALVE W.METER 10"PAL 12"PAL 17"MAG W.METER 10"PAL TRAF. CONTROL FIRE HUDRANT STORM DRAIN CLUSTER BERRY TREE 36" PECAN 14"PAL 15"PAL 22 LA 42 CHESNUT OAK RB(O) SIDEWALK LIGHT POST BENCHMARK PK NAIL ELEV. 19.16 16"PAL CM(O) CM(O) CM(O) 19.78 18.70 19.28 19.43 19.12 19.21 19.30 18.87 18.98 17.78 17.60 17.68 17.82 17.66 17.7117.74 18.1218.05 18.37 18.62 19.09 19.74 19.69 19.47 19.50 19.40 19.55 19.73 19.60 19.47 19.51 19.38 19.54 19.36 19.34 19.20 19.18 18.44 N 220568.66 E 2100617.34 N 220722.20 E 2100717.79 NEWCASTLE STREET 60' R\W CHARLES STREET 58' R\W BOUNDARY STREET R\W VARIES EXISTING 20' ACCESS EASEMENT ADJ BUILDING ADJ BUILDING 7' ~5'-9" 22' 23'-5 1 2" 23'-5 1 2" 22' 6' 23' 22'-5 1 2" 22'-5 1 2" 23' 2' 34' 30' 23' ~23' ~5'-10" ~5'-9" ~5'-3" 26' 38'-5" 26' ~2' 8' THIS IS A CONCEPT PLAN ONLY - NOT TO BE USED FOR ZONING nor CONSTRUCTION - SITE PLAN, DRAINAGE PLAN, ETC. BY OTHERS SITE PLAN SCALE 1" = 10' SHEET 9/22/2026 COVER SVC YARD ~19'-2 1 8" ~19'-2 1 8" SQUARE FOOTAGE FIRST FLOOR 592 SQFT SECOND FLOOR 520 SQFT PORCHES (SCREENED) 56 SQFT AREA OF ADDITION 628 SQFT AREA OF ADDITION 598 SQFT AREA OF ADDITION 592 SQFT AREA OF ADDITION 302 SQFT AREA OF ADDITION 160 SQFT AREA OF ADDITION 64 SQFT 19.09 PRINT SHOP 1st FLR FFL see SITE PLAN GARAGE SLAB FFL see SITE PLAN 9'-1 1 2" 1'-0 3 4" 10'-1 1 8" 1'-0 3 4" 9'-1 1 8" 1' 35'-6" 8'-2" 8' 6' 6' 3'-6" 3'-6" 6'-3" 6'-2 1 2" 8" 2'-10" 2'-10" 8" 4' 8" 2'-10" 2'-10" 8" 6'-2 1 2" 6'-3" TOP of RIDGE 2nd FLR CLG 1st FLR CLG 2nd FLR (12" TRUSS) WIN HDR HGT WIN HDR HGT 1st FLR (12" TRUSS) cLcL BRIDGEWATER CONSULTING LLC BEAUFORT, SOUTH CAROLINA nschoen@homesbybridgewater.com (843) 422-7778 HOMEOWNER SIGNATURE & DATE OF ACCEPTANCE REVISION DATE BOUNDARY STREET TOWNHOMES #1 TO #4 RESIDENCE 1010 BOUNDARY STREET BEAUFORT, SOUTH CAROLINA CONSTRUCTION DOCUMENT NOTES BUILDINGS SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE PROVISIONS OF THE 2021 INTERNATIONAL RESIDENTIAL CODE AND/OR LOCAL COUNTY BUILDING CODE (LOCAL CODE TO TAKE PRECEDENCE OVER ANY NOTES IN THESE PLANS). THESE PLANS ARE TO BE VERIFIED BY A STRUCTURAL ENGINEER. - ENGINEER'S DRAWINGS SHALL TAKE PRECEDENCE OVER ANY NOTES IN THESE PLANS. - THESE DRAWINGS SHALL TAKE PRECEDENCE FOR ALL DIMENSIONS. - MANUFACTURER'S INSTALLATION INSTRUCTIONS SHALL TAKE PRECEDENCE OVER PLAN NOTES. BUILDING PLANNING NOTES - SITE ADDRESS SHALL BE PROVIDED IN A POSITION THAT IS PLAINLY VISIBLE AND LEGIBLE FROM STREET FRONTING THE PROPERTY. - CONSTRUCTION, PROJECTIONS, OPENINGS AND PENETRATION OF EXTERIOR WALLS SHALL COMPLY w/ TABLE R302.1(1). - REVIEW FIRE RESISTANT CONSTRUCTION IF LESS THAN 5' SEPARATION BETWEEN STRUCTURES. - ALL HABITABLE ROOMS SHALL HAVE EXTERIOR GLAZING NOT LESS THAN 8% OF THEIR FLOOR AREA TO PROVIDE NATURAL LIGHT, OR THEY SHALL BE PROVIDED WITH ARTIFICIAL LIGHT ALL HABITABLE ROOMS SHALL BE PROVIDED WITH NATURAL VENTILATION THROUGH OPENINGS TO THE OUTDOOR AIR IN ACCORDANCE WITH SECTION R303, OR THEY SHALL BE PROVIDED WITH MECHANICAL VENTILATION. - LIGHT & VENTILATION FOR BATHROOMS, WCs AND SIMILAR ROOMS SHALL COMPLY WITH SECTION R303.3. - OUTDOOR AIR INTAKE OPENINGS SHALL BE LOCATED AT LEAST 10' FROM ANY HAZARDOUS OR NOXIOUS CONTAMINANT. - OUTSIDE EXHAUST OPENINGS SHALL BE LOCATED SO AS TO NOT CREATE A NUISANCE AND SHALL NOT BE DIRECTED ONTO WALKWAYS NOR PORCHES. - DWELLING SHALL BE PROVIDED WITH HEATING FACILITIES THAT WILL MAINTAIN A TEMPERATURE OF 68°F AT 3' ABOVE THE FLOOR AND 2' FROM EXTERIOR WALLS IN ALL HABITABLE ROOMS. - THE MIN. CEILING HEIGHT FOR HABITABLE ROOMS, HALLWAYS, CORRIDORS, BATHROOMS, WCs, LAUNDRY ROOMS & BASEMENTS SHALL NOT BE LESS THAN 7'. - SANITATION, TOILET, BATH & SHOWER SPACES PER SECTIONS R306 & R307 - MIN. 21" CLEARANCE IN FRONT OF FIXTURES. - SAFETY GLAZING SHALL BE IN ACCORDANCE WITH SECTION R308. - OPENINGS BETWEEN THE GARAGE AND THE DWELLING SHALL BE EQUIPPED WITH 1 3/4" THICK SOLID WOOD DOORS, HONEYCOMB CORE STEEL DOORS, OR 20 MINUTE FIRE-RATED DOORS. - ANY GARAGE SHALL BE SEPARATED FROM THE DWELLING & ATTIC AREA IN ACCORDANCE WITH SECTION R309. - GARAGE FLOOR SURFACES SHALL BE SLOPED TO A DRAIN TOWARD THE VEHICLE ENTRY POINT. - EVERY SLEEPING ROOM SHALL HAVE OPERABLE EMERGENCY ESCAPE AND RESCUE OPENINGS PER SECTION R311. - ALL EMERGENCY AND RESCUE OPENINGS SHALL HAVE A MIN. CLEAR OPENING OF 5.7sqft WITH A MIN. NET CLEAR OPENING HEIGHT OF 24" AND WIDTH OF 20" AND NO HIGHER THAN 44" AFF. - STAIRWAYS SHALL HAVE A MIN. HEADROOM HEIGHT OF 80". - STAIRWAYS SHALL HAVE A MINIMUM CLEAR WIDTH OF 31 1/2" AT AND BELOW THE HANDRAIL WHERE ONLY ONE HANDRAIL IS PROVIDED OR 27" WHERE HANDRAILS ARE PROVIDED ON BOTH SIDES. - A FLIGHT OF STAIRS SHALL HAVE NO MORE THAN 147" OF VERTICAL RISE BETWEEN FLOORS OR LANDINGS. - STAIRWELL TREADS SHALL BE AT LEAST 10" DEEP AND SHALL NOT EXCEED MORE THAN 3/8" VARIATION FROM LARGEST TO SMALLEST TREAD - STAIRWELL RISERS SHALL BE NOT GREATER THAN 7-3/4" IN HEIGHT AND SHALL NOT EXCEED 3/8" IN ANY FLIGHT OF STAIRS - SEE R311.7. - A CONTINUOUS HANDRAIL SHALL BE PROVIDED ON AT LEAST ONE SIDE OF THE STAIRWAY. - THE TOP OF THE HANDRAILS SHALL BE PLACED NOT LESS THAN 34" AND NOT MORE THAN 38" ABOVE THE NOSING OF THE TREADS. - GUARDS AT LEAST 36" IN HEIGHT SHALL BE PROVIDED WHERE PORCHES, BALCONIES OR RAISED FLOOR SURFACES ARE GREATER THAN 30". - GUARDS SHALL NOT HAVE OPENINGS THAT ALLOW PASSAGE OF A SPHERE 4" IN DIAMETER. - SMOKE ALARMS SHALL BE INSTALLED PER SECTION R314 IN EACH SLEEPING ROOM, OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS, ON EACH ADDITIONAL STORY OF THE DWELLING (INCLUDING BASEMENTS AND HABITABLE ATTICS, BUT BUT NOT INCLUDING CRAWL SPACES AND UNINHABITABLE ATTICS). - SMOKE ALARMS SHALL BE INTERCONNECTED AS INDICATED IN SECTION R314.4. - THE POWER SOURCE FOR SMOKE ALARMS SHALL COMPLY WITH SECTION R314.6. - PROTECTION OF WOOD FROM DECAY SHALL BE PROVIDED IN THE FOLLOWING LOCATIONS BY THE USE OF NATURALLY DURABLE WOOD OR WOOD THAT IS PRESERVATIVE-TREATED: (1) WOOD JOISTS OR FLOORS LESS THAN 18" FROM EXPOSED GROUND OR WOOD GIRDERS LESS THAN 12" FROM EXPOSED GROUND IN CRAWL SPACES OR UNEXCAVATED AREAS WITHIN THE BUILDING FOUNDATION (2) FLOOR FRAMING MEMBERS THAT REST ON CONCRETE OR MASONRY EXTERIOR WALLS AND ARE LESS THAN 8" FROM EXPOSED GROUND (3) SILLS AND SLEEPERS ON A CONCRETE OR MASONRY SLAB UNLESS SEPARATED BY SUCH A SLAB BY AN IMPERVIOUS MOISTURE BARRIER (4) WOOD SIDING, SHEATHING AND WALL FRAMING ON THE EXTERIOR OF A BUILDING LESS THAN 6" FROM THE GROUND. - AREAS SUBJECT TO TERMITE INFESTATION SHALL COMPLY WITH SECTION R318. - A ROUGH-FRAMED OPENING NOT LESS THAN 22"x30" w/30" MIN. HEADROOM SHALL BE PROVIDED TO ATTIC AREAS THAT HAVE A VERTICAL HEIGHT OF 30" OR GREATER (MEASURED TO THE BOTTOM OF ROOF FRAMING MEMBERS) OVER AN AREA GREATER THAN 30SQFT. - MECHANICAL EQUIPMENT IN ATTICS SHALL BE PROVIDED WITH ACCESS PER SECTION M1305.1.3. FLOOR JOIST SPAN REFERENCE 2021IRC - R502.3.1(2) - SOUTHERN YELLOW PINE #2 40psf LIVE LOAD - 20psf DEAD LOAD L/360 DEFLECTION SIZE SPACING SPAN 2 x 6 12" o/c 16" o/c 10' - 3" 9' - 4" 2 x 8 12" o/c 16" o/c 13' - 6" 11' - 10" 2 x 10 12" o/c 16" o/c 16' - 2" 14' - 0" 2 x 12 12" o/c 16" o/c 19' - 1" 16' - 6" *SPANS OVER 19' - 1" = ENGINEERED TRUSS or I-JOIST WALL & HEADER STUD SELECTION TABLE WFCM TABLE 3.22F SOUTHERN YELLOW PINE #2 MAX HEADER SPAN 3 UNSUPPORTED WALL HEIGHT 10' OR LESS GREATER THAN 10' 5 9 12 15 18 NUMBER OF JACK STUDS 1 1 2 2 2 2 NUMBER OF KING STUDS (END OF HEADER) 2 2 3 3 3 312" o/c 16" o/c 12" o/c 16" o/c STUD SPACING 2 2 3 3 3 3 2 2 3 4 5 5 2 2 3 3 4 4 WINDOW, DOOR & GARAGE DOOR HEADER SELECTION TABLE SOUTHERN YELLOW PINE #2 SUPPORTING ROOF, WALL AND FLOOR LIVE LOADS UP TO 20psf - 1.25 LOAD DURATION - 16' SPAN OF SUPPORTED ROOF & FLOOR FRAMING CLEAR OPENING MIN. HEADER SIZE 6' - 0" or LESS (2) 2 x 10 8' - 0" (3) 2 x 10 10' - 0" 12' - 0" 16' - 0" OVER 16' ENGINEERED by OTHERS 3-1/2" x 9-1/4" LVL 3-1/2" x 11-7/8" LVL 5-1/2" x 14" LVL CEILING JOIST SPAN REFERENCE R802.4.(2) - SOUTHERN YELLOW PINE #2 20psf LIVE LOAD - 10psf DEAD LOAD LIMITED STORAGE - L/240 DEFLECTION 2 x 4 12" o/c 16" o/c 9' - 3" 8' - 0" 2 x 6 13' - 11" 12' - 0" 2 x 8 17' - 7" 15' - 3" 2 x 10 20' - 11" 18' - 1" ROOF RAFTER SPAN REFERENCE R802.5.1(2) - SOUTHERN YELLOW PINE #2 20psf LIVE LOAD - L/240 DEFLECTION CEILING ATTACHED TO RAFTERS 13' - 6" 11' - 8" 17' - 1" 14' - 9" 20' - 3" 17' - 6" 23' - 10" 20' - 8" 12" o/c 16" o/c 12" o/c 16" o/c 12" o/c 16" o/c SIZE SPACING SPAN SIZE SPACING SPAN 2 x 4 2 x 6 2 x 8 2 x 10 2 x 12 2 x 12 12" o/c 16" o/c 12" o/c 16" o/c 12" o/c 16" o/c 12" o/c 16" o/c 12" o/c 16" o/c 12" o/c 16" o/c 9' - 0" 7' - 9" *19' - 1" *16' - 6" GROUND SNOW LOAD CLIMATIC & GEOGRAPHIC DESIGN CRITERIA - NOTE: STRUCTURAL ENGINEER TO VERIFY WIND SPEED SEISMIC DESIGN CATEGORY SUBJECT TO DAMAGE FROM WEATHERING FROST LINE TERMITE WINTER DESIGN TEMP ICE BARRIER UNDERLAYMENT REQUIRED FLOOD HAZARDS AIR FREEZING INDEX MEAN ANNUAL TEMP ELEVATION RENDERING NOT TO SCALE *THIS IS A CONCEPT ONLY, NOT MEANT AS CONSTRUCTION DRAWINGS SHEET INDEX LABEL TITLE DESCRIPTION OVER OVERVIEW SITE SITE PLAN XX FLOOR CONCEPT F1.1 FOUNDATION PLAN F1.2 FRAMED FOUNDATION WALLS A1.1 1ST FLOOR FRAMING PLAN A1.2 1ST FLOOR PLAN A1.3 2ND FLOOR FRAMING PLAN A1.4 2ND FLOOR PLAN A1.5 ROOF PLAN E1.1 ELECTRICAL PLAN XX ELEVATION CONCEPT A2.1 ALLEY ELEVATION A2.2 PRINT SHOP ELEVATION A2.3 CARTERET STREET ELEVATION M1.1 MECHANICAL PLAN REND PROJECT RENDERINGS A3.1 WINDOW, DOOR & TRIM DETAILS REVISIONS DATE DESCRIPTION 5/14/2026 5/17/2026 5/20/2026 5/23/2026 7/7/2026 7/8/2026 7/24/2026 8/1/26 8/19/2026 9/22/2026 5psf V-146mph CLASS D MODERATE >6 V. HEAVY 27°F NO see SURVEY 20°F 67.5°F SHEET 9/22/2026 XX SVC YARD ~19'-2 1 8" ~19'-2 1 8" SQUARE FOOTAGE FIRST FLOOR 592 SQFT SECOND FLOOR 520 SQFT PORCHES (SCREENED) 56 SQFT AREA OF ADDITION 628 SQFT AREA OF ADDITION 598 SQFT AREA OF ADDITION 592 SQFT AREA OF ADDITION 302 SQFT AREA OF ADDITION 160 SQFT AREA OF ADDITION 64 SQFT 19.09 1st FLR FFL see SITE PLAN GARAGE SLAB FFL see SITE PLAN 9'-1 1 2" 1'-0 3 4" 10'-1 1 8" 1'-0 3 4" 9'-1 1 8" 1' 35'-6" 8'-2" 8' TOP of RIDGE 2nd FLR CLG 1st FLR CLG 2nd FLR (12" TRUSS) WIN HDR HGT WIN HDR HGT 1st FLR (12" TRUSS) BOUNDARY STREET ELEVATION SCALE 1/4" = 1' - 0" CHARLES STREET ELEVATION SCALE 1/4" = 1' - 0" PRINT SHOP 1st FLR FFL see SITE PLAN GARAGE SLAB FFL see SITE PLAN 9'-1 1 2" 1'-0 3 4" 10'-1 1 8" 1'-0 3 4" 9'-1 1 8" 1' 35'-6" 8'-2" 8' 6' 6' 3'-6" 3'-6" 8" 4' 8" 2'-10" 2'-10" 8" 6'-2 1 2" 6'-3" TOP of RIDGE 2nd FLR CLG 1st FLR CLG 2nd FLR (12" TRUSS) WIN HDR HGT WIN HDR HGT 1st FLR (12" TRUSS) cL BRIDGEWATER CONSULTING LLC BEAUFORT, SOUTH CAROLINA nschoen@homesbybridgewater.com (843) 422-7778 HOMEOWNER SIGNATURE & DATE OF ACCEPTANCE REVISION DATE BOUNDARY STREET TOWNHOMES #1 TO #4 RESIDENCE 1010 BOUNDARY STREET BEAUFORT, SOUTH CAROLINA SHEET 9/22/2026 A2.1 SVC YARD ~19'-2 1 8" ~19'-2 1 8" SQUARE FOOTAGE FIRST FLOOR 592 SQFT SECOND FLOOR 520 SQFT PORCHES (SCREENED) 56 SQFT AREA OF ADDITION 628 SQFT AREA OF ADDITION 598 SQFT AREA OF ADDITION 592 SQFT AREA OF ADDITION 302 SQFT AREA OF ADDITION 160 SQFT AREA OF ADDITION 64 SQFT 19.09 ALLEY ELEVATION SCALE 1/4" = 1' - 0" BRIDGEWATER CONSULTING LLC BEAUFORT, SOUTH CAROLINA nschoen@homesbybridgewater.com (843) 422-7778 HOMEOWNER SIGNATURE & DATE OF ACCEPTANCE REVISION DATE BOUNDARY STREET TOWNHOMES #1 TO #4 RESIDENCE 1010 BOUNDARY STREET BEAUFORT, SOUTH CAROLINA SHEET 9/22/2026 A2.2 SVC YARD ~19'-2 1 8" ~19'-2 1 8" SQUARE FOOTAGE FIRST FLOOR 592 SQFT SECOND FLOOR 520 SQFT PORCHES (SCREENED) 56 SQFT AREA OF ADDITION 628 SQFT AREA OF ADDITION 598 SQFT AREA OF ADDITION 592 SQFT AREA OF ADDITION 302 SQFT AREA OF ADDITION 160 SQFT AREA OF ADDITION 64 SQFT 19.09 PRINT SHOP PRINT SHOP SIDE ELEVATION SCALE 1/4" = 1' - 0" BRIDGEWATER CONSULTING LLC BEAUFORT, SOUTH CAROLINA nschoen@homesbybridgewater.com (843) 422-7778 HOMEOWNER SIGNATURE & DATE OF ACCEPTANCE REVISION DATE BOUNDARY STREET TOWNHOMES #1 TO #4 RESIDENCE 1010 BOUNDARY STREET BEAUFORT, SOUTH CAROLINA CROSS SECTION SCALE 1/4" = 1' - 0" SHEET 9/22/2026 A2.3 SVC YARD ~19'-2 1 8" ~19'-2 1 8" SQUARE FOOTAGE FIRST FLOOR 592 SQFT SECOND FLOOR 520 SQFT PORCHES (SCREENED) 56 SQFT AREA OF ADDITION 628 SQFT AREA OF ADDITION 598 SQFT AREA OF ADDITION 592 SQFT AREA OF ADDITION 302 SQFT AREA OF ADDITION 160 SQFT AREA OF ADDITION 64 SQFT 19.09 BETWEEN BUILDING ELEVATION SCALE 1/4" = 1' - 0" BRIDGEWATER CONSULTING LLC BEAUFORT, SOUTH CAROLINA nschoen@homesbybridgewater.com (843) 422-7778 HOMEOWNER SIGNATURE & DATE OF ACCEPTANCE REVISION DATE BOUNDARY STREET TOWNHOMES #1 TO #4 RESIDENCE 1010 BOUNDARY STREET BEAUFORT, SOUTH CAROLINA CROSS SECTION SCALE 1/4" = 1' - 0" SHEET 9/22/2026 REND SVC YARD ~19'-2 1 8" ~19'-2 1 8" SQUARE FOOTAGE FIRST FLOOR 592 SQFT SECOND FLOOR 520 SQFT PORCHES (SCREENED) 56 SQFT AREA OF ADDITION 628 SQFT AREA OF ADDITION 598 SQFT AREA OF ADDITION 592 SQFT AREA OF ADDITION 302 SQFT AREA OF ADDITION 160 SQFT AREA OF ADDITION 64 SQFT 19.09 BRIDGEWATER CONSULTING LLC BEAUFORT, SOUTH CAROLINA nschoen@homesbybridgewater.com (843) 422-7778 HOMEOWNER SIGNATURE & DATE OF ACCEPTANCE REVISION DATE BOUNDARY STREET TOWNHOMES #1 TO #4 RESIDENCE 1010 BOUNDARY STREET BEAUFORT, SOUTH CAROLINA PROJECT RENDERINGS NOT TO SCALE *THIS IS A CONCEPT ONLY, NOT MEANT AS CONSTRUCTION DRAWINGS SHEET 9/22/2026 XX SVC YARD ~19'-2 1 8" ~19'-2 1 8" SQUARE FOOTAGE FIRST FLOOR 592 SQFT SECOND FLOOR 520 SQFT PORCHES (SCREENED) 56 SQFT AREA OF ADDITION 628 SQFT AREA OF ADDITION 598 SQFT AREA OF ADDITION 592 SQFT AREA OF ADDITION 302 SQFT AREA OF ADDITION 160 SQFT AREA OF ADDITION 64 SQFT 19.09 DN STACK W/D 18" 18" DW 30" SINK 36" VANITY 24" 18" 18" DW 30" SINK 36" VANITY 24" 30" RANGE 36" FRIDGE VERIFY SWING CLEARANCE SHELF 15"15" 48" UP UP FIREPROOF ELDH3672E ~98" HDR HGT FIREPROOF ELDH3672E ~98" HDR HGT 2480 3080 CO ELDH3672E ~98" HDR HGT ELDH3672E ~98" HDR HGT ELDH3672E ~98" HDR HGT ELDH3672E ~98" HDR HGT 3068 LHIS w/ DS TRANS ~98" HDR HGT ELDH3672E ~98" HDR HGT 3080 UP 7' 3'-8" 4'-7" 3'-9" 1' 1' 8'-9 1 2" 34' 2' 4'-6" 2'-4 1 2" 3'-4 1 2" 3'-9" 6' 5 1 2" 4'-3 1 2" 2'-3" 10' 3'-0 1 2" 3'-6" 5 1 2" 2' 8' 20' 2' 2' 24' 2' 4'-6"2'2'-4"4' 7'-11 1 2" 2'-10 1 2"4'-9" 4'-3 1 2" 3'-1"4'-7" 6'-3" 532 SQ FT V-GROOVE PINE CLG 8"x8" PT COLUMNS PT PICKETS @ 3-1/2"o/c TIMBERTECH T&G DECKING 0-0 LIVING AREA 109" GARAGE 12-3/4" FLOOR SYSTEM = 121-3/4" TOTAL RISE 7-1/4" RISE = 17 RISERS/16 TREADS FIREPROOF WALL DINING ENTRY ~10' CLG WOOD FLR GREAT ROOMKITCHEN ADJ BUILDING ADJ BUILDING FIREPROOF WALL COVERED PORCH DN 30" VANITY 42" VANITY 30" VANITY 42" VANITY TUB w/ TILE SURROUND LINEN SHLVS HALF-ROUND GUTTER w/ DOWNSPOUT HALF-ROUND GUTTER w/ DOWNSPOUT HALF-ROUND GUTTER w/ DOWNSPOUT ELDH3672E ~98" HDR HGT ELDH3672E ~98" HDR HGT ELDH3672E ~98" HDR HGT ELDH3672E ~98" HDR HGT 2870 ELDH3672E ~98" HDR HGT 2470 ELDH3672E ~98" HDR HGT ELDH3672E ~98" HDR HGT ELDH3672E ~98" HDR HGT 3070 2670 2470 24702470 FRAMELESS 3' 3'-6" 3'-6" 12' 2' 12'-5 1 2" 13'-1"2'-4 1 2"10'-6 1 2" 8'-4 1 2" 5'-4 1 2" 9'-3" 5'-9" 22' 4'-7" 3'-5 1 2" 3'-5 1 2" 11'-6" 6'-5 1 2"2'-10"3'-9 1 2"2'-4 1 2"6'-1 1 2"4'-5" 7' 10' 7' 2' 34' 22'-6 1 2" 22'-5 1 2" 6' ~12'-4 5 8" ~4'-1 7 8" 592 SQ FT ~9' CLG WOOD FLR LIVING AREA ~9' CLG WOOD FLR BEDROOM #2 TILE CHASE FIREPROOF WALL BEDROOM #1 ZERO ENTRY TILE SHWR TILE FIREPROOF WALL ADJ BUILDING ADJ BUILDING BATH #2 BATH #1 GMC YUKON BMW 3 SERIES GMC YUKON 12" 12" 12" 12"BRICKBRICK BRICK BRICK 3068 FIBERGLASS 3068 FIBERGLASS 16070 OH UP ~19'-2 1 8" ~11'-6" PT 2x: BRICK EXTERIOR PT 2x: BRICK EXTERIOR 1' 7' 12' 23' 4'-7" 5'-1" 13'-4" 26' 5'-6" 16' 1'-6" 9'-8" 12'-4" 2' 5'-9" 2' 20' 2' 12'-5 1 2" 4'-9" 19'-3" 2' 8' 34' 19' 7' 45' 66 SQ FT see ENGINEERING for ALL FOUNDATION DETAILS *THIS DRAWING to be USED for DIMENSIONAL PURPOSES ONLY* NOTE: ALL DRAIN LINES to DESCEND TO SLAB BEFORE RUNNING HORIZONTALLY ROUGH-IN HORIZONTAL DRAIN LINES BELOW SLAB! GARAGE SLAB ~9' CLG 4" TURNDOWN CONC. SLAB (see ENGINEERING) o/ VAPOR BARRIER SLOPE THRU OPENING *USE KEYWAY ONLY - NO SAW CUTS* EPOXY FINISH STREET VESTIBULE ~8' CLG DRYWALL BRICK TILE HERRINGBONE FLR STREET ENTRY HERRINGBONE BRICK FLR LIVING AREA FIREPROOF WALL ADJ BUILDING ADJ BUILDING FIREPROOF WALL 1st FLOOR PLAN SCALE 1/4" = 1' - 0" BRIDGEWATER CONSULTING LLC BEAUFORT, SOUTH CAROLINA nschoen@homesbybridgewater.com (843) 422-7778 HOMEOWNER SIGNATURE & DATE OF ACCEPTANCE REVISION DATE BOUNDARY STREET TOWNHOMES #1 TO #4 RESIDENCE 1010 BOUNDARY STREET BEAUFORT, SOUTH CAROLINA FOUNDATION PLAN SCALE 1/4" = 1' - 0" 2nd FLOOR PLAN SCALE 1/4" = 1' - 0" PLANTATION MIX GRAVEL DRIVE GMC YUKON BMW 3 SERIES GMC YUKON 12" 12" 12" 12"BRICKBRICK BRICK BRICK 12"12"BRICK BRICK 12"12" BRICKBRICK 12"BRICK 12"BRICK12"BRICK 12" BRICK 12" BRICK 12" BRICK 12"BRICK 12" BRICK 3068 FIBERGLASS 3068 FIBERGLASS 16070 OH ELDH3672E ~-42 1/4" HDR HGT ELDH3672E ~-42 1/4" HDR HGT 3068 FIBERGLASS 3068 FIBERGLASS 16070 OH 16070 OH16070 OH 3068 FIBERGLASS 3068 FIBERGLASS 3068 FIBERGLASS 3068 FIBERGLASS UP ~19'-2 1 8" ~11'-6" PT 2x: BRICK EXTERIOR PT 2x: BRICK EXTERIOR 1' 7' 12' 23' 22'-11" 4'-7" 5'-1" 13'-4" 26' 5'-6" 16' 1'-6" 22' 11" 22' 1'-6" 16' 5'-6" 9'-8" 12'-4" 2' 21' 5 1 2" 23'-5 1 2" 22' 5'-9" 2' 20' 2' 12'-5 1 2" 7' 1' 2' 1' 7' 12'-5 1 2" 2' 12'-4" 6'-4" 1'-4" 2' 4'-9" 19'-3" 2' 8' 34' 19' 7' 45' 11" 45' 26' 66 SQ FT see ENGINEERING for ALL FOUNDATION DETAILS *THIS DRAWING to be USED for DIMENSIONAL PURPOSES ONLY* NOTE: ALL DRAIN LINES to DESCEND TO SLAB BEFORE RUNNING HORIZONTALLY ROUGH-IN HORIZONTAL DRAIN LINES BELOW SLAB! GARAGE SLAB ~9' CLG 4" TURNDOWN CONC. SLAB (see ENGINEERING) o/ VAPOR BARRIER SLOPE THRU OPENING *USE KEYWAY ONLY - NO SAW CUTS* EPOXY FINISH STREET VESTIBULE ~8' CLG DRYWALL BRICK TILE HERRINGBONE FLR STREET ENTRY HERRINGBONE BRICK FLR LIVING AREA FIREPROOF WALL ADJ BUILDING ADJ BUILDING FIREPROOF WALL FIREPROOF WALL FIREPROOF WALL SHEET 9/22/2026 F1.1 SVC YARD ~19'-2 1 8" ~19'-2 1 8" SQUARE FOOTAGE FIRST FLOOR 592 SQFT SECOND FLOOR 520 SQFT PORCHES (SCREENED) 56 SQFT AREA OF ADDITION 628 SQFT AREA OF ADDITION 598 SQFT AREA OF ADDITION 592 SQFT AREA OF ADDITION 302 SQFT AREA OF ADDITION 160 SQFT AREA OF ADDITION 64 SQFT 19.09 BRIDGEWATER CONSULTING LLC BEAUFORT, SOUTH CAROLINA nschoen@homesbybridgewater.com (843) 422-7778 HOMEOWNER SIGNATURE & DATE OF ACCEPTANCE REVISION DATE BOUNDARY STREET TOWNHOMES #1 TO #4 RESIDENCE 1010 BOUNDARY STREET BEAUFORT, SOUTH CAROLINA FOUNDATION CONSTRUCTION NOTES ALL FOUNDATIONS TO COMPLY WITH IRC CHAPTER 4: FOUNDATIONS. UNDER FLOOR-SPACE VENTILATION IN ACCORDANCE WITH IRC R408. PROVIDE HYDROSTATIC VENTING PER FLOOD ZONE REQUIREMENTS. TYPICAL THICKENED SLAB: THICKENED SLAB @ CRITICAL BEARING POINTS TO BE MIN. 1'-0" DEEP x 2'-0" WIDE CONC., CENTERED ON WALL w/ (2) #5 REINFORCING BARS CONTINUOUS w/ 6x6 WWF (see ENGINEERING). TYPICAL REINFORCED CMU WALL FOOTING: TO BE MIN. 1'-0" DEEP x 2'-0" WIDE CONC. w/ (2) #5 REINFORCING BARS AND #5 BARS @ 3'-6" o/c EXTENDING TO MIN. 2'-0" OVERLAP w/ REINFORCING IN CMU WALL. TYPICAL REINFORCED CMU WALL: 8" x 8" x 16" CMU BLOCK w/ HORIZONTAL BED REINFORCING @ 8"o/c AND #5 REINFORCING BARS @ 3'-6" o/c w/ DOWELS TO MATCH (MIN. 2'-0" OVERLAP FROM FOOTING TO TOP OF CMU WALL) - FILL ALL CELLS. TYPICAL CONNECTING GRADE BEAM: FOOTINGS @ CONNECTING GRADE BEAM TO BE 12" DEEP x 12" WIDE CONC. w/ (2) #5 REINFORCING BARS CONTINUOUS. TYPICAL SLAB ON GRADE: 4" THICK CONC. o/ 6MIL VAPOR BARRIER w/ MIN. 12" x 16" TURNED DOWN EDGE w/ (2) #5 REINFORCING BARS CONTINUOUS AND 6x6 WWF. ALL SLABS SHALL HAVE CONTROL JOINTS SPACED 12'-15' APART (MIN): USE KEYWAY ONLY, NO SAW- CUTS. TYPICAL REINFORCED CMU PIER FOOTING: TO BE 12" DEEP x DOUBLE THE CMU PIER WIDTH CONC. w/ (2) #5 REINFORCING BARS EACH DIRECTION AND (4 TOTAL) #5 BARS EXTENDING TO MIN. 2'-0" OVERLAP w/ REINFORCING IN CMU PIER. TYPICAL REINFORCED CMU PIER: 8"x12"x12 " CMU BLOCK (or 8"x16"x16" CMU BLOCK AS NOTED ON PLAN) w/ HORIZONTAL BED REINFORCING @ 8" o/c AND (2) TOTAL #5 REINFORCING BARS w/ DOWELS TO MATCH (MIN. 2'-0" OVERLAP FROM FOOTING TO TOP OF CMU PIER) - FILL ALL CELLS. NOTE: STRUCTURAL ENGINEERING TO TAKE PRECEDENCE FOR ALL FOUNDATION SIZES, LOCATION AND PLACEMENT OF WORK DESCRIBED. FOUNDATION PLAN SCALE 1/4" = 1' - 0" DN STACK W/D 18" 18" DW 30" SINK 36" VANITY 24" 18" 18" DW 30" SINK 36" VANITY 24" 30" RANGE 36" FRIDGE VERIFY SWING CLEARANCE SHELF 15"15" 48" UP UP UP UP ELDH3672E ~98" HDR HGT ELDH3672E ~98" HDR HGT 2480 FIREPROOF ELDH3672E ~98" HDR HGT FIREPROOF ELDH3672E ~98" HDR HGT ELDH3672E ~98" HDR HGT ELDH3672E ~98" HDR HGT 2480 3080 CO ELDH3672E ~98" HDR HGT 3068 LHIS w/ DS TRANS ~98" HDR HGT ELDH3672E ~98" HDR HGT 3068 RHIS w/ DS TRANS ~98" HDR HGT ELDH3672E ~98" HDR HGT ELDH3672E ~98" HDR HGT ELDH3672E ~98" HDR HGT ELDH3672E ~98" HDR HGT ELDH3672E ~98" HDR HGT ELDH3672E ~98" HDR HGT 3068 LHIS w/ DS TRANS ~98" HDR HGT ELDH3672E ~98" HDR HGT 3080 3068 RHIS w/ DS TRANS ~98" HDR HGT ELDH3672E ~98" HDR HGT UP 7' 3'-8" 4'-7" 3'-9" 1' 1' 8'-9 1 2" 3'-8" 7' 4' 7' 14'-5 1 2" 12' 7' 3' 34' 2' 4'-6" 2'-4 1 2" 3'-4 1 2" 3'-9" 6' 5 1 2" 4'-3 1 2" 2'-3" 10' 3'-0 1 2" 3'-6" 5 1 2" 2' 8' 20' 2' 42'-11" 2' 22' 28' 8' 2' 24' 2' 6' 6' 10'24' 4'-6"2'2'-4"4' 7'-11 1 2" 2'-10 1 2"4'-9" 4'-3 1 2" 3'-1"4'-7" 2' 6'-3" 6'-2 1 2" 18' 6'-2 1 2" 6'-3" 532 SQ FT V-GROOVE PINE CLG 8"x8" PT COLUMNS PT PICKETS @ 3-1/2"o/c TIMBERTECH T&G DECKING 0-0 LIVING AREA 109" GARAGE 12-3/4" FLOOR SYSTEM = 121-3/4" TOTAL RISE 7-1/4" RISE = 17 RISERS/16 TREADS FIREPROOF WALL DINING ENTRY ~10' CLG WOOD FLR GREAT ROOMKITCHEN ADJ BUILDING ADJ BUILDING FIREPROOF WALL COVERED PORCH COVERED PORCH COVERED PORCH SHEET 9/22/2026 A1.2 1st FLOOR PLAN SCALE 1/4" = 1' - 0" SVC YARD ~19'-2 1 8" ~19'-2 1 8" SQUARE FOOTAGE FIRST FLOOR 592 SQFT SECOND FLOOR 520 SQFT PORCHES (SCREENED) 56 SQFT AREA OF ADDITION 628 SQFT AREA OF ADDITION 598 SQFT AREA OF ADDITION 592 SQFT AREA OF ADDITION 302 SQFT AREA OF ADDITION 160 SQFT AREA OF ADDITION 64 SQFT 19.09 BRIDGEWATER CONSULTING LLC BEAUFORT, SOUTH CAROLINA nschoen@homesbybridgewater.com (843) 422-7778 HOMEOWNER SIGNATURE & DATE OF ACCEPTANCE REVISION DATE BOUNDARY STREET TOWNHOMES #1 TO #4 RESIDENCE 1010 BOUNDARY STREET BEAUFORT, SOUTH CAROLINA FRAMING CONSTRUCTION NOTES EXTERIOR WALLS: 1/2" PLYWOOD SHEATHING o/2x4 and/or 2x6 SPF @ 16"o/c w/ BLOCKING MIDSPAN (UNLESS OTHERWISE NOTED). INTERIOR WALLS: 2x4 and/or 2x6 SPF @ 16"o/c w/ BLOCKING MIDSPAN (UNLESS OTHERWISE NOTED). FIRST FLOOR SYSTEM: 2x12 SYP @ 16"o/c w/ 3/4" T&G PLYWOOD (OR EQUIVALENT), GLUED & NAILED. 2nd FLOOR SYSTEM: 14" OPEN WEB TRUSSES (per ENGINEERING) w/ 3/4" T&G PLYWOOD (OR EQUIVALENT), GLUED & NAILED - ENGINEERED TRUSS SHOP DRAWINGS TAKE PRECEDENCE. CEILING JOISTS: 2x SYP per ENGINEERING. ROOF RAFTERS: 1/2" EXT SHEATHING NAILED ON 2x SYP @ 16"o/c (per ENGINEERING) w/ SIMPSON HURRICANE CLIPS. NOTE: STRUCTURAL ENGINEERING TO TAKE PRECEDENCE FOR ALL FRAMING MEMBER SIZES, LOCATION AND PLACEMENT OF WORK DESCRIBED. DN 30" VANITY 42" VANITY 30" VANITY 42" VANITY TUB w/ TILE SURROUND LINEN SHLVS HALF-ROUND GUTTER w/ DOWNSPOUT HALF-ROUND GUTTER w/ DOWNSPOUT HALF-ROUND GUTTER w/ DOWNSPOUT HALF-ROUND GUTTER w/ DOWNSPOUT HALF-ROUND GUTTER w/ DOWNSPOUT HALF-ROUND GUTTER w/ DOWNSPOUT HALF-ROUND GUTTER w/ DOWNSPOUT HALF-ROUND GUTTER w/ DOWNSPOUT ELDH3672E ~98" HDR HGT ELDH3672E ~98" HDR HGT ELDH3672E ~98" HDR HGT ELDH3672E ~98" HDR HGT ELDH3672E ~98" HDR HGT ELDH3672E ~98" HDR HGT 2870 ELDH3672E ~98" HDR HGT ELDH3672E ~98" HDR HGT 2470 ELDH3672E ~98" HDR HGT ELDH3672E ~98" HDR HGT ELDH3672E ~98" HDR HGT ELDH3672E ~98" HDR HGT ELDH3672E ~98" HDR HGT ELDH3672E ~98" HDR HGT ELDH3672E ~98" HDR HGT ELDH3672E ~98" HDR HGT 3070 2670 2470 ELDH3672E ~98" HDR HGT ELDH3672E ~98" HDR HGT 24702470 ELDH3672E ~98" HDR HGT ELDH3672E ~98" HDR HGT FRAMELESS 24' 3' 3'-6" 3'-6" 12' 2' 12'-5 1 2" 18' 12'-5 1 2" 2' 12' 7' 13'-1"2'-4 1 2"10'-6 1 2" 8'-4 1 2" 5'-4 1 2" 9'-3" 5'-9" 22' 46'-11" 4'-7" 3'-5 1 2" 3'-5 1 2" 11'-6" 6'-5 1 2"2'-10"3'-9 1 2"2'-4 1 2"6'-1 1 2"4'-5" 7' 10' 7' 2' 34' 22'-6 1 2" 22'-5 1 2" 11" 22'-5 1 2" 6' ~12'-4 5 8" ~4'-1 7 8" 592 SQ FT ~9' CLG WOOD FLR LIVING AREA ~9' CLG WOOD FLR BEDROOM #2 TILE CHASE FIREPROOF WALL BEDROOM #1 ZERO ENTRY TILE SHWR TILE FIREPROOF WALL ADJ BUILDING ADJ BUILDING BATH #2 BATH #1 SHEET 9/22/2026 A1.4 SVC YARD ~19'-2 1 8" ~19'-2 1 8" SQUARE FOOTAGE FIRST FLOOR 592 SQFT SECOND FLOOR 520 SQFT PORCHES (SCREENED) 56 SQFT AREA OF ADDITION 628 SQFT AREA OF ADDITION 598 SQFT AREA OF ADDITION 592 SQFT AREA OF ADDITION 302 SQFT AREA OF ADDITION 160 SQFT AREA OF ADDITION 64 SQFT 19.09 BRIDGEWATER CONSULTING LLC BEAUFORT, SOUTH CAROLINA nschoen@homesbybridgewater.com (843) 422-7778 HOMEOWNER SIGNATURE & DATE OF ACCEPTANCE REVISION DATE BOUNDARY STREET TOWNHOMES #1 TO #4 RESIDENCE 1010 BOUNDARY STREET BEAUFORT, SOUTH CAROLINA FRAMING CONSTRUCTION NOTES EXTERIOR WALLS: 1/2" PLYWOOD SHEATHING o/2x4 and/or 2x6 SPF @ 16"o/c w/ BLOCKING MIDSPAN (UNLESS OTHERWISE NOTED). INTERIOR WALLS: 2x4 and/or 2x6 SPF @ 16"o/c w/ BLOCKING MIDSPAN (UNLESS OTHERWISE NOTED). FIRST FLOOR SYSTEM: 2x12 SYP @ 16"o/c w/ 3/4" T&G PLYWOOD (OR EQUIVALENT), GLUED & NAILED. 2nd FLOOR SYSTEM: 14" OPEN WEB TRUSSES (per ENGINEERING) w/ 3/4" T&G PLYWOOD (OR EQUIVALENT), GLUED & NAILED - ENGINEERED TRUSS SHOP DRAWINGS TAKE PRECEDENCE. CEILING JOISTS: 2x SYP per ENGINEERING. ROOF RAFTERS: 1/2" EXT SHEATHING NAILED ON 2x SYP @ 16"o/c (per ENGINEERING) w/ SIMPSON HURRICANE CLIPS. NOTE: STRUCTURAL ENGINEERING TO TAKE PRECEDENCE FOR ALL FRAMING MEMBER SIZES, LOCATION AND PLACEMENT OF WORK DESCRIBED. 2nd FLOOR PLAN SCALE 1/4" = 1' - 0" 3 : 12 3 : 123 : 12 3 : 12 3 : 123 : 12 0 : 12 0 : 12 3 : 12 3 : 123 : 12 3 : 12 3 : 123 : 12 0 : 12 0 : 12 0 : 12 0 : 12 0 : 12 0 : 12 0 : 12 0 : 12 0 : 12 0 : 12 0 : 12 0 : 120 : 12 0 : 120 : 12 0 : 12 0 : 12 0 : 12 0 : 12 0 : 12 SHEET 9/22/2026 A1.5 SVC YARD ~19'-2 1 8" ~19'-2 1 8" SQUARE FOOTAGE FIRST FLOOR 592 SQFT SECOND FLOOR 520 SQFT PORCHES (SCREENED) 56 SQFT AREA OF ADDITION 628 SQFT AREA OF ADDITION 598 SQFT AREA OF ADDITION 592 SQFT AREA OF ADDITION 302 SQFT AREA OF ADDITION 160 SQFT AREA OF ADDITION 64 SQFT 19.09 BRIDGEWATER CONSULTING LLC BEAUFORT, SOUTH CAROLINA nschoen@homesbybridgewater.com (843) 422-7778 HOMEOWNER SIGNATURE & DATE OF ACCEPTANCE REVISION DATE BOUNDARY STREET TOWNHOMES #1 TO #4 RESIDENCE 1010 BOUNDARY STREET BEAUFORT, SOUTH CAROLINA ROOF PLAN SCALE 1/4" = 1' - 0" CORNICE & FASCIA DETAIL SCALE 3/4" = 1' - 0" ROOF CONSTRUCTION NOTES ROOF EAVE DIMENSIONS ARE GENERALLY (UNLESS NOTED OTHERWISE) FROM EXTERIOR SIDE OF BEARING WALL/BEAM TO FINISHED FACE OF EAVE. see SECTIONS for CLARIFICATION. EXHAUST VENTS (PLUMBING/HVAC/OTHER) SHALL BE GROUPED IN ATTIC TO LIMIT THE NUMBER OF ROOF PENETRATIONS. ALL ROOF PENETRATIONS SHALL BE HIDDEN FROM VIEW AND LOCATED TOWARD THE REAR OF THE HOUSE (PAINTED TO MATCH ROOF COLOR). ROOF RAFTERS: 1/2" EXT SHEATHING NAILED ON 2x SYP @ 16"o/c (per ENGINEERING) w/ SIMPSON HURRICANE CLIPS. NOTE: STRUCTURAL ENGINEERING TO TAKE PRECEDENCE FOR ALL FRAMING MEMBER SIZES, LOCATION AND PLACEMENT OF WORK DESCRIBED. Rendering of Townhome building with units 1 – 4: Rendering of Townhome building with units 5 – 8: Rendering of Townhome building s (rear) with units 9 – 12:

Source: City of Beaufort website. First collected Oct 17, 2026.