Historic District Review Board — Agenda Packet
City of Beaufort · Beaufort County · Historic District Review Board · meeting of Oct 14, 2026 · Agenda packets
Open the original document More from City of Beaufort
Text
Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.
1
M
EETING AGENDA
CITY OF BEAUFORT - HISTORIC DISTRICT REVIEW BOARD
Wednesday, October 14, 2026, at 2:00 pm
City Hall, Council Chambers, 2nd Floor – 1911 Boundary Street, Beaufort, SC
Please click the link below to access the Zoom meeting:
https://us02web.zoom.us/j/84548359275?pwd=gffRaUj9broGCjWVYYn4aOdz0RreHf.1
Password: 516372 Meeting ID: 845 4835 9275 Call in Phone #: +1 929 205 6099
STATEMENT OF MEDIA NOTIFICATION: “In accordance with South Carolina Code of Laws, 1976, Section
30-4-80(d), as amended, all local media were duly notified of the time, date, place, and agenda of this meeting.”
Please note, this meeting will also be live streamed via Zoom. Anybody interested can watch this meeting on
the City's YouTube page: “City Beaufort SC”.
Note: A project will not be reviewed if the applicant or representative is not present at the meeting.
I. Call to Order
II. Review of Minutes
• August 12, 2026 - Meeting
III. Applications
A. 1
010 Boundary Street/1112 Charles Street, PIN: R120 004 000 0071-/0072-/0073 0000:
Construction of eight (8) new townhomes (two 4-unit buildings) & four (4) duplexes (two 2-
unit buildings; infill development)
Applicant(s): Ben and Christine Wiley
The applicants are requesting final approval for new construction/infill-development of two 4-unit
townhome buildings (attached) fronting Boundary Street, and two duplex (2-unit) buildings in the rear
which would be accessible from both Charles and Newcastle Streets.
IV. Adjournment
1
Historic District Review Board
Meeting Minutes – August 12, 2026
CALL TO ORDER 1:00
A meeting of the Historic District Review Board was called to order by Mike Sutton, Chairman. The meeting
was held in-person in Council Chambers on Wednesday, August 12, 2026 at 2:00 PM. The meeting was
broadcasted via zoom and live-streamed on YouTube. You can view this meeting at the City’s page; City of
Beaufort Government.
ATTENDEES
Members in attendance: Mike Sutton (Chair), Kim Petrella, Richard Drake, and Rita Wilson.
Member Absent: Eric Berman, (Vice-Chair).
Staff in attendance: Curt Freese, Community Development Director, Christopher Klement, Community
Development Planner III, Nick Navia, Community Development Planner II, Julie Bachety, Administrative
Assistant II, as well as Maxwell Larkby, Community Development Planning Intern, and Meadors Architects
(online).
REVIEW OF THE JULY 8, 2026 MINUTES 1:11
Ms. Wilson noted under Attendees, Grady Woods name needs to be replaced with Richard Drake.
Motion: Ms. Petrella made a motion to accept the minutes. Mr. Drake seconded the motion. The motion
passed unanimously.
All Historic District Review Board Meeting minutes are recorded and can be found on the City’s website at
http://www.cityofbeaufort.org/AgendaCenter.
CONSENT AGENDA ITEM 2:07
A. 1411 North Street, PIN: R120 004 000 0663 0000: Approval of Bailey Bill Tax Credit application for
completed rehabilitation of historically contributing dwelling (Emil E. Lengnick House)
Applicant: Rossdhu Properties, LLC c/o Mr. Steve Goggans, Owner
The applicant is requesting approval for a 10-year property tax freeze for previously completed historic
renovation work to the historically contributing dwelling, based on the local Bailey Bill Act.
Mr. Sutton recused himself from this project. Ms. Petrella, Board Secretary, took over as Chair since Eric
Berman, Vie-Chair was absent from the meeting.
2
The Board were all in favor of the changes and the updates.
APPLICATIONS 13:30
B. 910 Harrington Street, PIN: R120 004 000 0256 0000: Change-after request for exterior siding
material and replacement windows for renovation/upfit of contributing dwelling
Applicant: Carlton Linnen, Owner
Mr. Sutton returned to the meeting at this point. Ms. Petrella relinquished being Chair.
The applicant is requesting change of the previously approved exterior materials, including installation
of Hardie Plank lap-siding (instead of wood siding) and installation of appropriate replacement
windows (instead of original window repair). The original Certificate of Appropriateness letter was
issued June 1, 2026.
Nick Navia presented his staff report.
Public Comment:
Lise Sundrla, Historic Beaufort Foundation (HBF) Director, stated we are in support of the application.
Public comment closed.
Motion: Ms. Petrella made a motion to approve the application as presented. Mr. Drake seconded the
motion. The motion passed unanimously.
C. 1010 Boundary Street/1112 Charles Street, PIN: R120 004 000 0071-/0072- 31:14
/0073 0000: Construction of eight (8) new townhomes (two 4-unit buildings)
& four (4) duplexes (two 2-unit buildings; infill development)
Applicant: MediaLink LLC (Ben and Christine Wiley), Applicant
The applicant is requesting conceptual/preliminary approval for new construction/infill-development of
two 4-unit townhome buildings fronting Boundary Street, and two duplex (2-unit) buildings in the rear
which would be accessible from both Charles and Newcastle Streets.
Ms. Wilson recused herself from this project.
Christopher Klement presented his staff report.
Lise Sundrla, HBF Director, commended the applicants on their improvements of the design. Ms.
Sundrla stated HBF is in agreement with staff’s comments and recommendations.
Public comment closed.
3
Motion: Mr. Drake made a motion to approve the application conceptually. Ms. Petrella seconded the
motion. The motion passed unanimously.
Ms. Wilson returned to the meeting at this time.
MISCELLANEOUS DISCUSSION 1:24:20
The Board discussed possible changes to the application packet and process associated with the local Bailey
Bill Tax Abatement Program. Staff suggested having a Board Training workshop in September to go over
possible amendments to the 2022 Beaufort Preservation Manual, together with the Appendix on the
Northwest Quadrant Design Manual in presenting and reviewing more alternative material selections for
historic rehabilitation that could be recommended and made permissible.
ADJOURNMENT 1:36:28
Mr. Drake made a motion to adjourn which was seconded by Ms. Petrella. The meeting ended at 3:36 pm.
STAFF REPORT: HISTORIC DISTRICT REVIEW BOARD (HDRB)
1010 BOUNDARY STREET / CHARLES ST. / NEWCASTLE ST.
DATE: October 14, 2026
1
GENERAL INFORMATION
Applicant: MediaLink LLC - Ben and Christine Wiley
Site Address / PIN: 1010 Boundary Street / 1112 Charles Street / PIN #’s: R120 004 000 0071
0000; R120 004 000 0072 0000; R120 004 000 0073 0000
Applicant's Request: Applicant is requesting final approval for 12 dwelling units divided
between 4 buildings, consisting of:
• Two 4-unit attached townhome buildings fronting Boundary Street
(8 dwellings), and
• Two 2-unit (duplex) buildings in the rear, accessed from
Charles/Newcastle Streets (4 dwellings)
Current Zoning: T5-URBAN CORRIDOR (T5-UC)
Contributing/Neighborhood Currently vacant lots / The Northwest Quadrant neighborhood
Flood Zone/Base Flood Flood Zone: X, Elevation: 17 ft – 19 ft (BFE: 13 ft)
Overall Lot Size 17,024 Sqft (0.391 acres)
[5,566 sqft + 5,766 sqft + 5,692 sqft]
ZONING DISTRICT INFORMATION
T5-URBAN CORRIDOR (T5-UC)
Lot Width at Setback: N/A
Minimum Lot Size: N/A
Max Lot Coverage: 100%
Frontage Build Out 60% min
Front Setback – Primary 0 ft min – 15 ft max
Side Setback – Primary Corner/Alley: 0 ft – 15 ft
Interior: 0 ft
Rear Setback – Primary 5 ft min; from alley: 0 ft.
Building Height: Primary Structures: 5 stories max; 3.5 stories max in & fronting Historic
District
Accessory Structures: 2 stories max
SURROUNDING ZONING, LAND USE AND REQUIRED BUFFERS
Adjacent Zoning Adjacent Land Uses Setbacks for Adjacent Zoning
/Buffer required if rezoned
North: T5-UC 1211 Newcastle St. - Non-
Contributing; Commercial N/A
South: T5-UC 1108 Charles St. - Non-
Contributing; Commercial N/A
East: T5-UC 1107 Charles St. - Non-
Contributing; Commercial N/A
West: T5-UC 1012 Boundary St. - Non-
Contributing; Commercial N/A
2
Background:
This project has been presented at two HDRB meetings (1st meeting: June 10th, 2026; 2nd meeting: August 12th, 2026),
After changes to the original proposal which included 3 sets of townhouse buildings with 4 units each, the
conceptual approval now consists of two 4 -unit townhouse buildings fronting Boundary Street , and two duplex
buildings accessed via Charles and Newcastle Streets, for a total of 12 units.
The Board had previously decided to table this request based on various concerns, including massing & scaling,
building design, lot placement & setbacks as well as existing utilities. After various revisions were made and
presented at the project’s second HDRB Meeting on August 12 th, the Board granted conceptual approval, and the
applicants are now requesting final approval.
Project Timeline:
Jan.
2026
Feb. Mar. Apr. May Jun. Jul. Aug. Sep. Oct. Nov. Dec.
5/6:
1st HTRC
Meeting
6/10:
1st HDRB
Meeting
- tabled
7/15:
2nd HTRC
Meeting
8/12:
2nd HDRB
Meeting
10/14:
3rd
HDRB
Meeting
Summary of the HDRB Meeting (8/12/2026):
Applicant: MediaLink, LLC c/o Ben and Christine Wiley
The applicant is requesting conceptual/preliminary approval for new construction/infill-development of two 4-unit
townhome buildings fronting Boundary Street, and two duplex (2-unit) buildings in the rear which would be
accessible from both Charles and Newcastle Streets.
Ms. Wilson recused herself from the project.
Nick Navia presented his staff report.
Public Comment:
Lise Sundrla, HBF Director, commended the applicants on their improvements of the design. Ms. Sundrla stated
HBF is in agreement with staff’s comments and recommendations.
Motion: Mr. Drake made a motion to approve the application conceptually. Ms. Petrella seconded the motion.
The motion passed unanimously.
Tree Removal Proposed:
A few existing Specimen/Landmark trees may be affected by this in-fill development request. Specimen/Landmark
tree status and potential mitigation to be assessed during Development Design Review process.
Surrounding Area:
The subject properties are located along Boundary Street on the northern edge of the Beaufort Historic District and
the “Northwest Quadrant” neighborhood. The subject properties are currently vacant. The surrounding area can be
3
characterized as “urban, mixed use”, consisting of both commercial shops and businesses as well as student
housing and college-related (USCB) uses nearby.
Determination of adequate historic integrity for New Construction, Infill, Additions and Demolition:
As per the Beaufort Preservation Manual (Chapter 5) and the Beaufort Development Code (Section 4.7) , the
compatibility of new infill construction as well as major renovations within the Beaufort Historic District is
determined in consideration with the following principles : 1. Location, 2. Design, 3. Setting, 4. Materials, 5.
Workmanship, 6. Feeling and 7. Association. See staff analysis and recommendations below.
1010 Boundary Street – Staff Analysis
1. Current Lots / Lot Consolidation
Staff Analysis:
• Staff supports the future lot consolidation on the basis that the applicant receives Conceptual/Preliminary
Approval and an SCDOT Encroachment Permit for access from Charles Street.
4
1010 Boundary Street – Overview of main changes (staff analysis):
2. Building placements/Lot configuration
Inititally presented Site Plan (6-10-2026)
5
Previously presented version of Site Plan (as per 8-12-2026)
6
Latest version of Site Plan (as per 9-22-2026)
7
Staff Analysis of Site Plan changes:
• The latest design revision includes separated front porches for the rear duplex buildings, where those were combined before
• The previous revision of an increased setback to the adjacent property to the west (“Alpha Graphics”) from formerly 2ft. to now 5ft. 9in. has
remained in place
• 6ft. separation between the two Townhouse buildings in the middle and a 2ft. setback from Charles St. on the east (no changes).
• Boundary Street-fronting Townhouses are served with ground-level 2-car garages in the rear, accessible through an Access Easement that
connects with Charles Street on the east and Newcastle Street to the south and west; the rear duplexes will have side-loading garages (no
changes).
1010 Boundary Street – Staff Analysis:
• Building Elevations
[Front elevation, facing Boundary Street - 6-10-2026]
8
[Front elevation, facing Boundary Street as previously submitted on 8-12-2026]
Main staff architectural (Meadors) comments:
• Windows seem off-centered on wall
• Uneven window spacing
• Consider flipping units so that each unit has its own entrance
• Move downspouts into recesses to give the recesses more purpose
• Can the downspout placed so obviously in the middle be removed?
9
10
Side elevations of
townhome unit facing
Charles Street (left: 6-10-
2026; right: 8-12-2026)
Side elevation of
townhome unit facing
Print Shop (8-12-2026)
11
[Front elevation, facing Boundary Street / Side elevation facing Charles Street – latest submittal as per 9-22-2026]
Right: Side elevation of
townhome unit facing
Print Shop (9-22-2026)
Left: Side elevation of
unit facing other
townhouse building to
the east (9-22-2026)
12
Staff Analysis – Boundary Street-facing townhouses:
• Comparing design between conceptual approval (8-12-26) and latest submittal (9-22-26):
Formerly combined front porches have been separated with individual roofs now in place
Downspout locations have been moved/recessed
Previous gabled roofline on side elevation facing Charles St. has been
replaced with a flat roof pitch (0:12) [see roof plan below]
Eave brackets are now fully contained with cornice
Formerly blank panels below bay windows now include detailing
Prior faux ground floor (garage) windows have been replaced with real
windows with shutters
Side elevation of unit
facing Charles Street to
the east (9-22-2026)
Roof plan – eastern
townhouse building facing
Charles St. (9-22-2026)
13
Rear duplexes – Staff Analysis
Right: Rear duplex
rendering as presented on
8-12-26
Below: Rear duplex – latest
submittal per 9-22-26
14
Left: Front elevation – latest
submittal; Below: Side
elevation with garage (9-22-
26)
Left: Rear elevation – latest
submittal (9-22-26)
15
Staff Analysis –2-unit (duplex) buildings at the rear of the property:
• Comparing design between conceptual approval (8-12-26) and latest submittal (9-22-26):
Formerly combined front porches have been separated with individual roofs now in place
Eave brackets have been fully included in cornice
Screened-in service yards have been moved to the front corner (were placed at rear corner previously)
Ground floor windows at rear elevation are smaller than first- and second-floor window sizes (as per Sec. 4.6.3.C.2.c – specific to
T4/T5: “i¡.Facades. should.have.several.window.sizes.with.smaller.ones.above¡.This.is.particularl y.important.when.buildings.rise.more.
than.8.stories¡”)
16
4.7.2 Integrity Guidelines (as per Beaufort
Development Code)
Rationale
Present
Staff Analysis of Rationale
1. Location: This is the relationship between the
property and its historical context.
YES Boundary Street is currently characterized
by mixed land-uses (residential &
commercial) in a high-density pattern (T5-
UC zone). The proposal for townhomes and
duplexes complies with the intent for more
urbanity along this downtown corridor.
2. Design: This is the combination of elements
that create the feeling of a district or structure.
These elements include building patterns,
streetscapes, site elements, building size, mass
and scale, spatial relationships, and specific
architectural elements and details.
YES After latest revisions, the applicants have
successfully implemented a more coherent,
historically compliant building design which
includes many typical residential building
design aspects of the
Beaufort/Savannah/the Lowcountry.
3. Setting: This is the physical environment of a
property and should be evaluated on its context
as well as on the historical role the property has
played and continues to play. Important features
include topography, vegetation, man-made
features, and relationships between existing
structures and their surroundings.
YES The proposal respects the historic integrity
and more dense urban land-use mix of the
Boundary Street corridor.
4. Materials: These are the physical elements
that make up a property or district.
YES Final Design approval with material list
provided; staff review of material
cutsheets/specs to be done at
permitting/review level.
5. Workmanship: This is the physical evidence
of the crafts of a particular culture or time
period. This particularly applies to rehabilitation
projects, but for new infill projects, workmanship
of surrounding structures should be considered
and respected.
YES Choice for low-maintenance yet high-quality
material combinations for walls/siding
consisting of Hardi-plank and brick,
amongst others, positively contributes to a
high workmanship.
6. Feeling: This is the property's expression of
the aesthetic or historic sense of a particular
period of time. This particularly applies to
rehabilitation projects, but for new infill projects,
the feeling of surrounding structures should be
considered and respected.
YES The proposal will positively add to the
urbanity of the Boundary Street corridor
while creating more historical building
characteristics at the same time.
7. Association: This is the direct link between an
important historic event or person and the
property.
N/A N/A
17
FINDINGS AND RECOMMENDATIONS
Staff recommends PRELIMINARY APPROVAL with the following conditions and recommendations as per the
Beaufort Preservation Manual and requirements of the Beaufort Code:
Previously stated recommendations not resolved are listed below:
1. Staff has concerns about the brick ledge at the top of the brick veneer and has concerns that this is a
“suburban” detail , and not a typical detail found in the historic district . To appear as a traditional
masonry base, the veneer should either be thin brick, or the floor framing should be cantilevered to
allow the siding and brick face to be aligned on the same plane.
2. The lower roofline and its gutter interferes with several brackets as the roofline travels around the
building. These conflicts should be resolved.
3. Windows and doors are still off -center on the front facades . The windows in the great room (1 st floor)
and bedroom #1 (2nd floor) should shift to even the spacing.
4. There is still a false window on the right-side elevation. Staff requests the applicant consider adjusting
the kitchen layout to accommodate a real window in these locations.
5. The applicant is utilizing low-pitched roofs to lower the scale of the building. The applicant shall provide
a cutsheet of the proposed roof material for review. It is recommended that the applicant utilize a metal
drip edge at the roof perimeter to transition to the low-sloped roof material. If any of the low sloped roof
material is visible from the public right-of-way (street level), then it must be screened behind a parapet
wall.
Additional Recommendations for Preliminary Approval:
1. The ground floor windows on the duplex’s Charles Street elevation are narrower and shorter than the
windows on the floors above. Per Section 4.6.3.C.2.c, “Façades should have several windows sizes with
smaller ones above.” This applies to all other elevations with smaller ground floor windows.
2. One of the side elevations for the 4-unit buildings does not have ground floor windows (between units 4
and 5). Even though these facades are internal to the lot, they will still be highly visible from Boundary
Street. Staff recommends windows be added in these areas , unless noted otherwise by the Building
Official.
3. No details have been provided in this submission. Applicant to provide typical details including window
and door head/sill/jamb details, column, decking/trim connections, brick to siding connections, typical
eave conditions, etc.
4. Applicant to note that all SDL windows and doors with glass shall have exterior -applied muntins and
interior spacer bars.
5. Applicant to clarify the material for the overhead garage doors. Please note that faux wood grain
textures are not allowed.
6. Applicant to clarify the main roofing product. The material list notes that the main roofing material will
be GAF Timberline, which is an asphalt shingle. However, the main roof is flat, and asphalt shingles
cannot be installed on flat roofs.
7. Staff could be supportive of a 5V metal roof over the stoops, but would recommend the applicant
consider a standing seam metal roof to reduce the amount of fastener holes in the roof.
8. Applicant to provide cutsheets for both types of exterior lighting.
18
9. Applicant to provide a detail section through the garage door overhang. This appears to have an
awkward connection with the cementitious skirtboard above the brick, and no brackets are shown.
Staff recommends lowering the height of the overhang, and adding end brackets so that the overhang
appears visually supported. The garage door overhangs on the townhouse units appear to connect to
one another. Staff recommends each garage door have a separate, visually supported overhang.
10. Staff recommends shifting the left and right side windows on the duplexes to be more properly centered
within the façade. This comment also applies to the windows on the rear townhouse façade.
PLANTATION MIX
GRAVEL DRIVE
COVERED
PORCH
56 SQ FT ⏍
SVC
YARD
HEATED FOOTPRINT AREA
(UNIT #1)
592 SQ FT ⏍
FOOTPRINT
UNIT #2
628 SQ FT ⏍
UNIT #3
628 SQ FT ⏍
PORCH
UNIT #4
592 SQ FT ⏍
SVC
YARD
UNIT #10
598 SQ FT ⏍
UNIT #9
598 SQ FT ⏍
SVC
YARD
SVC
YARD
UNIT #12
598 SQ FT ⏍
UNIT #11
598 SQ FT ⏍
SVC
YARD
SVC
YARD
SVC
YARD
PORCH PORCH
UNIT #5
592 SQ FT ⏍
SVC
YARD
UNIT #6
628 SQ FT ⏍
SVC
YARD
UNIT #7
628 SQ FT ⏍
SVC
YARD
UNIT #8
592 SQ FT ⏍
PORCHPORCH PORCHPORCH
PORCH PORCH
SVC
YARD
~19'-2
1 8"
~11'-6"
~19'-2
1 8"
~11'-6"
xxxxxx
x
x
x
x x x x
H
Y D
~19'-2
1 8"
~11'-6"
~19'-2
1 8"
~11'-6"
~19'-2
1 8"
~11'-6"
~19'-2
1 8"
~11'-6"
~57'-8"
1'
21'-5 1 2"
21'-5 1 2"
1'
2'
20'
1'
22'-5 1 2" 22'-5 1 2"
1'
20'
2'
1ST FLOOR FFL
~10' ABV GARAGE SLAB
5,696 sq. ft.
0.131 acres
5,777 sq. ft.
0.133 acres
5,569 sq. ft.
0.128 acres
R120 004 000 0071 0000
R120 004 000 0072 0000
R120 004 000 0073 0000
RB(O)
CALC. PT.
EXISTING20' ACCESS EASEMENT
P
P
P
P
P
P
SIDEWALK
EXISTING
15' ACCESS EASEMENT
DIANNE RUSHING
BR2 INVESTMENTS LLC
JOE SINGLETON
54"LO
CM(O)
GAS
METER
BUILDING
GRAVEL DRIVEWAY
RB(O) GAS
VALVE
W.METER
10"PAL
12"PAL
17"MAG
W.METER
10"PAL
TRAF.
CONTROL
FIRE
HUDRANT
STORM
DRAIN
CLUSTER
BERRY TREE
36" PECAN
14"PAL
15"PAL
22 LA
42 CHESNUT OAK
RB(O)
SIDEWALK
LIGHT
POST
BENCHMARK
PK NAIL
ELEV. 19.16
16"PAL
CM(O)
CM(O)
CM(O)
19.78
18.70
19.28
19.43
19.12
19.21
19.30 18.87
18.98
17.78
17.60
17.6817.82
17.66
17.71
17.7418.1218.0518.37
18.62
19.09
19.74
19.69
19.47
19.50
19.40 19.55
19.73
19.6019.47
19.51
19.38
19.54
19.36
19.34
19.20
19.18
18.44
N 220568.66
N 220722.20
E 2100717.79
NEWCASTLE STREET 60' R\W
CHARLES STREET 58' R\W
BOUNDARY STREET R\W VARIES
EXISTING 20' ACCESS EASEMENT
ADJ
BUILDING
ADJ BUILDING
7'
~5'-9"
22' 23'-5 1 2" 23'-5 1 2" 22' 6' 23' 22'-5 1 2" 22'-5 1 2" 23'
2'
34'30'23'~23'
~5'-10"
~5'-9"
~5'-3"
26' 38'-5" 26'
~2'
8'
SHEET
9/22/2026
OVER
SVC
YARD
~19'-2
1 8"
~19'-2
1 8"
SQUARE FOOTAGE
FIRST FLOOR 592 SQFT
SECOND FLOOR 520 SQFT
PORCHES (SCREENED) 56 SQFT
AREA OF ADDITION 628 SQFT
AREA OF ADDITION 598 SQFT
AREA OF ADDITION 592 SQFT
AREA OF ADDITION 302 SQFT
AREA OF ADDITION 160 SQFT
AREA OF ADDITION 64 SQFT
19.09
PRINT SHOP
1st FLR FFL
see SITE PLAN
GARAGE SLAB FFL
see SITE PLAN 9'-1 1 2"
1'-0 3 4"
10'-1 1 8"
1'-0 3 4"
9'-1 1 8"
1'
35'-6"
8'-2" 8'
6' 6' 3'-6" 3'-6"
6'-3" 6'-2 1 2"
8"
2'-10" 2'-10"
8"
4'
8"
2'-10" 2'-10"
8"
6'-2 1 2" 6'-3"
TOP of RIDGE
2nd FLR CLG
1st FLR CLG
2nd FLR (12" TRUSS)
WIN HDR HGT
WIN HDR HGT
1st FLR (12" TRUSS)
cLcL
54" DINING
TV 60"
2'
36'
8'2'24'
8'
8'
87'-11"
18'
26'-5 1 2"
7'
532 SQ FT
LIVING AREA
DINING
ENTRY
GREAT ROOMKITCHEN
COVERED PORCH
COVERED PORCH
GMC
YUKON
BMW
3 SERIES
23'
66 SQ FT
GARAGE SLAB
~9' CLG
4" TURNDOWN CONC. SLAB
(see ENGINEERING)
o/ VAPOR BARRIER
SLOPE THRU OPENING
*USE KEYWAY ONLY - NO SAW CUTS*
EPOXY FINISH
STREET
VESTIBULE
STREET ENTRY
LIVING AREA
QUEEN
30"x19"
DRESSER KING
11'-0" X 12'-7"
592 SQ FT
8'-8" X 12'-1"
LIVING AREA
BEDROOM #2
CHASE
BEDROOM #1
BATH #2
BATH #1
BRIDGEWATER CONSULTING LLC
BEAUFORT, SOUTH CAROLINA
nschoen@homesbybridgewater.com
(843) 422-7778
HOMEOWNER SIGNATURE &
DATE OF ACCEPTANCE REVISION DATE BOUNDARY STREET TOWNHOMES #1 TO #4 RESIDENCE
1010 BOUNDARY STREET
BEAUFORT, SOUTH CAROLINA
FLOOR OVERVIEW
SCALE 3/16 = 1' - 0"
*THIS IS A CONCEPT ONLY, NOT MEANT AS CONSTRUCTION DRAWINGS
PLANTATION MIX
GRAVEL DRIVE
COVERED
PORCH
56 SQ FT ⏍
SVC
YARD
HEATED FOOTPRINT AREA
(UNIT #1)
592 SQ FT ⏍
FOOTPRINT
UNIT #2
628 SQ FT ⏍ UNIT #3
628 SQ FT ⏍
PORCH
UNIT #4
592 SQ FT ⏍
SVC
YARD
UNIT #10
598 SQ FT ⏍
UNIT #9
598 SQ FT ⏍
SVC
YARD
SVC
YARD
UNIT #12
598 SQ FT ⏍
UNIT #11
598 SQ FT ⏍
SVC
YARD
SVC
YARD
SVC
YARD
PORCH PORCH
UNIT #5
592 SQ FT ⏍
SVC
YARD
UNIT #6
628 SQ FT ⏍
SVC
YARD
UNIT #7
628 SQ FT ⏍
SVC
YARD
UNIT #8
592 SQ FT ⏍
PORCH
PORCH PORCHPORCH
PORCH PORCH
SVC
YARD
~19'-2
1 8"
~11'-6" ~19'-2
1 8"
~11'-6"
xxxxxx
x
x
x
x x x x
H
Y D
~19'-2
1 8"
~11'-6"
~19'-2
1 8"
~11'-6"
~19'-2
1 8"
~11'-6"
~19'-2
1 8"
~11'-6"
~57'-8"
1'
21'-5 1 2"
21'-5 1 2"
1'
2'
20'
1'
22'-5 1 2" 22'-5 1 2"
1'
20'
2'
1ST FLOOR FFL
~10' ABV GARAGE SLAB
5,696 sq. ft.
0.131 acres
5,777 sq. ft.
0.133 acres
5,569 sq. ft.
0.128 acres
R120 004 000 0071 0000
R120 004 000 0072 0000
R120 004 000 0073 0000
RB(O)
CALC. PT.
EXISTING
20' ACCESS EASEMENT
P
P
P
P
P
P
SIDEWALK
EXISTING
15' ACCESS EASEMENT
DIANNE RUSHING
BR2 INVESTMENTS LLC
JOE SINGLETON
54"LO
CM(O)
GAS
METER
BUILDING
GRAVEL DRIVEWAY
RB(O) GAS
VALVE
W.METER
10"PAL
12"PAL
17"MAG
W.METER
10"PAL
TRAF.
CONTROL
FIRE
HUDRANT
STORM
DRAIN
CLUSTER
BERRY TREE
36" PECAN
14"PAL
15"PAL
22 LA
42 CHESNUT OAK
RB(O)
SIDEWALK
LIGHT
POST
BENCHMARK
PK NAIL
ELEV. 19.16
16"PAL
CM(O)
CM(O)
CM(O)
19.78
18.70
19.28
19.43
19.12
19.21
19.30 18.87
18.98
17.78
17.60
17.68
17.82
17.66
17.7117.74
18.1218.05
18.37
18.62
19.09
19.74
19.69
19.47
19.50
19.40
19.55
19.73
19.60
19.47
19.51
19.38
19.54
19.36
19.34
19.20
19.18
18.44
N 220568.66
E 2100617.34
N 220722.20
E 2100717.79
NEWCASTLE STREET 60' R\W
CHARLES STREET 58' R\W
BOUNDARY STREET R\W VARIES
EXISTING
20' ACCESS EASEMENT
ADJ
BUILDING
ADJ BUILDING
7'
~5'-9"
22' 23'-5 1 2" 23'-5 1 2" 22' 6' 23' 22'-5 1 2" 22'-5 1 2" 23'
2'
34'
30'
23'
~23'
~5'-10"
~5'-9"
~5'-3"
26' 38'-5" 26'
~2'
8'
THIS IS A CONCEPT PLAN ONLY
- NOT TO BE USED FOR ZONING nor CONSTRUCTION -
SITE PLAN, DRAINAGE PLAN, ETC. BY OTHERS
SITE PLAN
SCALE 1" = 10'
SHEET
9/22/2026
COVER
SVC
YARD
~19'-2
1 8"
~19'-2
1 8"
SQUARE FOOTAGE
FIRST FLOOR 592 SQFT
SECOND FLOOR 520 SQFT
PORCHES (SCREENED) 56 SQFT
AREA OF ADDITION 628 SQFT
AREA OF ADDITION 598 SQFT
AREA OF ADDITION 592 SQFT
AREA OF ADDITION 302 SQFT
AREA OF ADDITION 160 SQFT
AREA OF ADDITION 64 SQFT
19.09
PRINT SHOP
1st FLR FFL
see SITE PLAN
GARAGE SLAB FFL
see SITE PLAN 9'-1 1 2"
1'-0 3 4"
10'-1 1 8"
1'-0 3 4"
9'-1 1 8"
1'
35'-6"
8'-2" 8'
6' 6' 3'-6" 3'-6"
6'-3" 6'-2 1 2"
8"
2'-10" 2'-10"
8"
4'
8"
2'-10" 2'-10"
8"
6'-2 1 2" 6'-3"
TOP of RIDGE
2nd FLR CLG
1st FLR CLG
2nd FLR (12" TRUSS)
WIN HDR HGT
WIN HDR HGT
1st FLR (12" TRUSS)
cLcL
BRIDGEWATER CONSULTING LLC
BEAUFORT, SOUTH CAROLINA
nschoen@homesbybridgewater.com
(843) 422-7778
HOMEOWNER SIGNATURE &
DATE OF ACCEPTANCE REVISION DATE BOUNDARY STREET TOWNHOMES #1 TO #4 RESIDENCE
1010 BOUNDARY STREET
BEAUFORT, SOUTH CAROLINA
CONSTRUCTION DOCUMENT NOTES
BUILDINGS SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE PROVISIONS OF THE 2021
INTERNATIONAL RESIDENTIAL CODE AND/OR LOCAL COUNTY BUILDING CODE (LOCAL CODE TO TAKE
PRECEDENCE OVER ANY NOTES IN THESE PLANS). THESE PLANS ARE TO BE VERIFIED BY A
STRUCTURAL ENGINEER.
- ENGINEER'S DRAWINGS SHALL TAKE PRECEDENCE OVER ANY NOTES IN THESE PLANS.
- THESE DRAWINGS SHALL TAKE PRECEDENCE FOR ALL DIMENSIONS.
- MANUFACTURER'S INSTALLATION INSTRUCTIONS SHALL TAKE PRECEDENCE OVER PLAN NOTES.
BUILDING PLANNING NOTES
- SITE ADDRESS SHALL BE PROVIDED IN A POSITION THAT IS PLAINLY VISIBLE AND LEGIBLE FROM
STREET FRONTING THE PROPERTY.
- CONSTRUCTION, PROJECTIONS, OPENINGS AND PENETRATION OF EXTERIOR WALLS SHALL
COMPLY w/ TABLE R302.1(1).
- REVIEW FIRE RESISTANT CONSTRUCTION IF LESS THAN 5' SEPARATION BETWEEN STRUCTURES.
- ALL HABITABLE ROOMS SHALL HAVE EXTERIOR GLAZING NOT LESS THAN 8% OF THEIR FLOOR
AREA TO PROVIDE NATURAL LIGHT, OR THEY SHALL BE PROVIDED WITH ARTIFICIAL LIGHT
ALL HABITABLE ROOMS SHALL BE PROVIDED WITH NATURAL VENTILATION THROUGH OPENINGS TO
THE OUTDOOR AIR IN ACCORDANCE WITH SECTION R303, OR THEY SHALL BE PROVIDED WITH
MECHANICAL VENTILATION.
- LIGHT & VENTILATION FOR BATHROOMS, WCs AND SIMILAR ROOMS SHALL COMPLY WITH SECTION
R303.3.
- OUTDOOR AIR INTAKE OPENINGS SHALL BE LOCATED AT LEAST 10' FROM ANY HAZARDOUS OR
NOXIOUS CONTAMINANT.
- OUTSIDE EXHAUST OPENINGS SHALL BE LOCATED SO AS TO NOT CREATE A NUISANCE AND SHALL
NOT BE DIRECTED ONTO WALKWAYS NOR PORCHES.
- DWELLING SHALL BE PROVIDED WITH HEATING FACILITIES THAT WILL MAINTAIN A TEMPERATURE
OF 68°F AT 3' ABOVE THE FLOOR AND 2' FROM EXTERIOR WALLS IN ALL HABITABLE ROOMS.
- THE MIN. CEILING HEIGHT FOR HABITABLE ROOMS, HALLWAYS, CORRIDORS, BATHROOMS, WCs,
LAUNDRY ROOMS & BASEMENTS SHALL NOT BE LESS THAN 7'.
- SANITATION, TOILET, BATH & SHOWER SPACES PER SECTIONS R306 & R307
- MIN. 21" CLEARANCE IN FRONT OF FIXTURES.
- SAFETY GLAZING SHALL BE IN ACCORDANCE WITH SECTION R308.
- OPENINGS BETWEEN THE GARAGE AND THE DWELLING SHALL BE EQUIPPED WITH 1 3/4" THICK
SOLID WOOD DOORS, HONEYCOMB CORE STEEL DOORS, OR 20 MINUTE FIRE-RATED DOORS.
- ANY GARAGE SHALL BE SEPARATED FROM THE DWELLING & ATTIC AREA IN ACCORDANCE WITH
SECTION R309.
- GARAGE FLOOR SURFACES SHALL BE SLOPED TO A DRAIN TOWARD THE VEHICLE ENTRY POINT.
- EVERY SLEEPING ROOM SHALL HAVE OPERABLE EMERGENCY ESCAPE AND RESCUE OPENINGS
PER SECTION R311.
- ALL EMERGENCY AND RESCUE OPENINGS SHALL HAVE A MIN. CLEAR OPENING OF 5.7sqft WITH A
MIN. NET CLEAR OPENING HEIGHT OF 24" AND WIDTH OF 20" AND NO HIGHER THAN 44" AFF.
- STAIRWAYS SHALL HAVE A MIN. HEADROOM HEIGHT OF 80".
- STAIRWAYS SHALL HAVE A MINIMUM CLEAR WIDTH OF 31 1/2" AT AND BELOW THE HANDRAIL
WHERE ONLY ONE HANDRAIL IS PROVIDED OR 27" WHERE HANDRAILS ARE PROVIDED ON BOTH
SIDES.
- A FLIGHT OF STAIRS SHALL HAVE NO MORE THAN 147" OF VERTICAL RISE BETWEEN FLOORS OR
LANDINGS.
- STAIRWELL TREADS SHALL BE AT LEAST 10" DEEP AND SHALL NOT EXCEED MORE THAN 3/8"
VARIATION FROM LARGEST TO SMALLEST TREAD
- STAIRWELL RISERS SHALL BE NOT GREATER THAN 7-3/4" IN HEIGHT AND SHALL NOT EXCEED 3/8" IN
ANY FLIGHT OF STAIRS - SEE R311.7.
- A CONTINUOUS HANDRAIL SHALL BE PROVIDED ON AT LEAST ONE SIDE OF THE STAIRWAY.
- THE TOP OF THE HANDRAILS SHALL BE PLACED NOT LESS THAN 34" AND NOT MORE THAN 38"
ABOVE THE NOSING OF THE TREADS.
- GUARDS AT LEAST 36" IN HEIGHT SHALL BE PROVIDED WHERE PORCHES, BALCONIES OR RAISED
FLOOR SURFACES ARE GREATER THAN 30".
- GUARDS SHALL NOT HAVE OPENINGS THAT ALLOW PASSAGE OF A SPHERE 4" IN DIAMETER.
- SMOKE ALARMS SHALL BE INSTALLED PER SECTION R314 IN EACH SLEEPING ROOM, OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS, ON EACH ADDITIONAL
STORY OF THE DWELLING (INCLUDING BASEMENTS AND HABITABLE ATTICS, BUT BUT NOT INCLUDING
CRAWL SPACES AND UNINHABITABLE ATTICS).
- SMOKE ALARMS SHALL BE INTERCONNECTED AS INDICATED IN SECTION R314.4.
- THE POWER SOURCE FOR SMOKE ALARMS SHALL COMPLY WITH SECTION R314.6.
- PROTECTION OF WOOD FROM DECAY SHALL BE PROVIDED IN THE FOLLOWING LOCATIONS BY THE
USE OF NATURALLY DURABLE WOOD OR WOOD THAT IS PRESERVATIVE-TREATED: (1) WOOD JOISTS
OR FLOORS LESS THAN 18" FROM EXPOSED GROUND OR WOOD GIRDERS LESS THAN 12" FROM
EXPOSED GROUND IN CRAWL SPACES OR UNEXCAVATED AREAS WITHIN THE BUILDING FOUNDATION
(2) FLOOR FRAMING MEMBERS THAT REST ON CONCRETE OR MASONRY EXTERIOR WALLS AND ARE
LESS THAN 8" FROM EXPOSED GROUND (3) SILLS AND SLEEPERS ON A CONCRETE OR MASONRY
SLAB UNLESS SEPARATED BY SUCH A SLAB BY AN IMPERVIOUS MOISTURE BARRIER (4) WOOD
SIDING, SHEATHING AND WALL FRAMING ON THE EXTERIOR OF A BUILDING LESS THAN 6" FROM THE
GROUND.
- AREAS SUBJECT TO TERMITE INFESTATION SHALL COMPLY WITH SECTION R318.
- A ROUGH-FRAMED OPENING NOT LESS THAN 22"x30" w/30" MIN. HEADROOM SHALL BE PROVIDED
TO ATTIC AREAS THAT HAVE A VERTICAL HEIGHT OF 30" OR GREATER (MEASURED TO THE BOTTOM
OF ROOF FRAMING MEMBERS) OVER AN AREA GREATER THAN 30SQFT.
- MECHANICAL EQUIPMENT IN ATTICS SHALL BE PROVIDED WITH ACCESS PER SECTION M1305.1.3.
FLOOR JOIST SPAN REFERENCE
2021IRC - R502.3.1(2) - SOUTHERN YELLOW PINE #2
40psf LIVE LOAD - 20psf DEAD LOAD
L/360 DEFLECTION
SIZE SPACING SPAN
2 x 6
12" o/c
16" o/c
10' - 3"
9' - 4"
2 x 8
12" o/c
16" o/c
13' - 6"
11' - 10"
2 x 10
12" o/c
16" o/c
16' - 2"
14' - 0"
2 x 12
12" o/c
16" o/c
19' - 1"
16' - 6"
*SPANS OVER 19' - 1" = ENGINEERED TRUSS or I-JOIST
WALL & HEADER STUD
SELECTION TABLE
WFCM TABLE 3.22F
SOUTHERN YELLOW PINE #2
MAX HEADER SPAN
3
UNSUPPORTED
WALL HEIGHT
10' OR LESS
GREATER
THAN 10'
5 9 12 15 18
NUMBER OF JACK STUDS
1 1 2 2 2 2
NUMBER OF KING STUDS
(END OF HEADER)
2 2 3 3 3 312" o/c
16" o/c
12" o/c
16" o/c
STUD
SPACING
2 2 3 3 3 3
2 2 3 4 5 5
2 2 3 3 4 4
WINDOW, DOOR & GARAGE DOOR
HEADER SELECTION TABLE
SOUTHERN YELLOW PINE #2 SUPPORTING ROOF,
WALL AND FLOOR LIVE LOADS UP TO 20psf - 1.25 LOAD DURATION -
16' SPAN OF SUPPORTED ROOF & FLOOR FRAMING
CLEAR OPENING MIN. HEADER SIZE
6' - 0" or LESS (2) 2 x 10
8' - 0" (3) 2 x 10
10' - 0"
12' - 0"
16' - 0"
OVER 16' ENGINEERED by OTHERS
3-1/2" x 9-1/4" LVL
3-1/2" x 11-7/8" LVL
5-1/2" x 14" LVL
CEILING JOIST SPAN REFERENCE
R802.4.(2) - SOUTHERN YELLOW PINE #2
20psf LIVE LOAD - 10psf DEAD LOAD
LIMITED STORAGE - L/240 DEFLECTION
2 x 4
12" o/c
16" o/c
9' - 3"
8' - 0"
2 x 6
13' - 11"
12' - 0"
2 x 8
17' - 7"
15' - 3"
2 x 10
20' - 11"
18' - 1"
ROOF RAFTER SPAN REFERENCE
R802.5.1(2) - SOUTHERN YELLOW PINE #2
20psf LIVE LOAD - L/240 DEFLECTION
CEILING ATTACHED TO RAFTERS
13' - 6"
11' - 8"
17' - 1"
14' - 9"
20' - 3"
17' - 6"
23' - 10"
20' - 8"
12" o/c
16" o/c
12" o/c
16" o/c
12" o/c
16" o/c
SIZE SPACING SPAN
SIZE SPACING SPAN
2 x 4
2 x 6
2 x 8
2 x 10
2 x 12
2 x 12
12" o/c
16" o/c
12" o/c
16" o/c
12" o/c
16" o/c
12" o/c
16" o/c
12" o/c
16" o/c
12" o/c
16" o/c
9' - 0"
7' - 9"
*19' - 1"
*16' - 6"
GROUND
SNOW
LOAD
CLIMATIC & GEOGRAPHIC DESIGN CRITERIA - NOTE: STRUCTURAL ENGINEER TO VERIFY
WIND
SPEED
SEISMIC
DESIGN
CATEGORY
SUBJECT TO DAMAGE FROM
WEATHERING FROST LINE TERMITE
WINTER
DESIGN
TEMP
ICE BARRIER
UNDERLAYMENT
REQUIRED
FLOOD
HAZARDS
AIR
FREEZING
INDEX
MEAN
ANNUAL
TEMP
ELEVATION RENDERING
NOT TO SCALE
*THIS IS A CONCEPT ONLY, NOT MEANT AS CONSTRUCTION DRAWINGS
SHEET INDEX
LABEL TITLE DESCRIPTION
OVER OVERVIEW
SITE SITE PLAN
XX FLOOR CONCEPT
F1.1 FOUNDATION PLAN
F1.2 FRAMED FOUNDATION WALLS
A1.1 1ST FLOOR FRAMING PLAN
A1.2 1ST FLOOR PLAN
A1.3 2ND FLOOR FRAMING PLAN
A1.4 2ND FLOOR PLAN
A1.5 ROOF PLAN
E1.1 ELECTRICAL PLAN
XX ELEVATION CONCEPT
A2.1 ALLEY ELEVATION
A2.2 PRINT SHOP ELEVATION
A2.3 CARTERET STREET ELEVATION
M1.1 MECHANICAL PLAN
REND PROJECT RENDERINGS
A3.1 WINDOW, DOOR & TRIM DETAILS
REVISIONS
DATE DESCRIPTION
5/14/2026
5/17/2026
5/20/2026
5/23/2026
7/7/2026
7/8/2026
7/24/2026
8/1/26
8/19/2026
9/22/2026
5psf V-146mph CLASS D MODERATE >6 V. HEAVY 27°F NO see SURVEY 20°F 67.5°F
SHEET
9/22/2026
XX
SVC
YARD
~19'-2
1 8"
~19'-2
1 8"
SQUARE FOOTAGE
FIRST FLOOR 592 SQFT
SECOND FLOOR 520 SQFT
PORCHES (SCREENED) 56 SQFT
AREA OF ADDITION 628 SQFT
AREA OF ADDITION 598 SQFT
AREA OF ADDITION 592 SQFT
AREA OF ADDITION 302 SQFT
AREA OF ADDITION 160 SQFT
AREA OF ADDITION 64 SQFT
19.09
1st FLR FFL
see SITE PLAN
GARAGE SLAB FFL
see SITE PLAN 9'-1 1 2"
1'-0 3 4"
10'-1 1 8"
1'-0 3 4"
9'-1 1 8"
1'
35'-6"
8'-2" 8'
TOP of RIDGE
2nd FLR CLG
1st FLR CLG
2nd FLR (12" TRUSS)
WIN HDR HGT
WIN HDR HGT
1st FLR (12" TRUSS)
BOUNDARY STREET ELEVATION
SCALE 1/4" = 1' - 0"
CHARLES STREET ELEVATION
SCALE 1/4" = 1' - 0"
PRINT SHOP
1st FLR FFL
see SITE PLAN
GARAGE SLAB FFL
see SITE PLAN 9'-1 1 2"
1'-0 3 4"
10'-1 1 8"
1'-0 3 4"
9'-1 1 8"
1'
35'-6"
8'-2" 8'
6' 6' 3'-6" 3'-6"
8"
4'
8"
2'-10" 2'-10"
8"
6'-2 1 2" 6'-3"
TOP of RIDGE
2nd FLR CLG
1st FLR CLG
2nd FLR (12" TRUSS)
WIN HDR HGT
WIN HDR HGT
1st FLR (12" TRUSS)
cL
BRIDGEWATER CONSULTING LLC
BEAUFORT, SOUTH CAROLINA
nschoen@homesbybridgewater.com
(843) 422-7778
HOMEOWNER SIGNATURE &
DATE OF ACCEPTANCE REVISION DATE BOUNDARY STREET TOWNHOMES #1 TO #4 RESIDENCE
1010 BOUNDARY STREET
BEAUFORT, SOUTH CAROLINA
SHEET
9/22/2026
A2.1
SVC
YARD
~19'-2
1 8"
~19'-2
1 8"
SQUARE FOOTAGE
FIRST FLOOR 592 SQFT
SECOND FLOOR 520 SQFT
PORCHES (SCREENED) 56 SQFT
AREA OF ADDITION 628 SQFT
AREA OF ADDITION 598 SQFT
AREA OF ADDITION 592 SQFT
AREA OF ADDITION 302 SQFT
AREA OF ADDITION 160 SQFT
AREA OF ADDITION 64 SQFT
19.09
ALLEY ELEVATION
SCALE 1/4" = 1' - 0"
BRIDGEWATER CONSULTING LLC
BEAUFORT, SOUTH CAROLINA
nschoen@homesbybridgewater.com
(843) 422-7778
HOMEOWNER SIGNATURE &
DATE OF ACCEPTANCE REVISION DATE BOUNDARY STREET TOWNHOMES #1 TO #4 RESIDENCE
1010 BOUNDARY STREET
BEAUFORT, SOUTH CAROLINA
SHEET
9/22/2026
A2.2
SVC
YARD
~19'-2
1 8"
~19'-2
1 8"
SQUARE FOOTAGE
FIRST FLOOR 592 SQFT
SECOND FLOOR 520 SQFT
PORCHES (SCREENED) 56 SQFT
AREA OF ADDITION 628 SQFT
AREA OF ADDITION 598 SQFT
AREA OF ADDITION 592 SQFT
AREA OF ADDITION 302 SQFT
AREA OF ADDITION 160 SQFT
AREA OF ADDITION 64 SQFT
19.09
PRINT SHOP
PRINT SHOP SIDE ELEVATION
SCALE 1/4" = 1' - 0"
BRIDGEWATER CONSULTING LLC
BEAUFORT, SOUTH CAROLINA
nschoen@homesbybridgewater.com
(843) 422-7778
HOMEOWNER SIGNATURE &
DATE OF ACCEPTANCE REVISION DATE BOUNDARY STREET TOWNHOMES #1 TO #4 RESIDENCE
1010 BOUNDARY STREET
BEAUFORT, SOUTH CAROLINA
CROSS SECTION
SCALE 1/4" = 1' - 0"
SHEET
9/22/2026
A2.3
SVC
YARD
~19'-2
1 8"
~19'-2
1 8"
SQUARE FOOTAGE
FIRST FLOOR 592 SQFT
SECOND FLOOR 520 SQFT
PORCHES (SCREENED) 56 SQFT
AREA OF ADDITION 628 SQFT
AREA OF ADDITION 598 SQFT
AREA OF ADDITION 592 SQFT
AREA OF ADDITION 302 SQFT
AREA OF ADDITION 160 SQFT
AREA OF ADDITION 64 SQFT
19.09
BETWEEN BUILDING ELEVATION
SCALE 1/4" = 1' - 0"
BRIDGEWATER CONSULTING LLC
BEAUFORT, SOUTH CAROLINA
nschoen@homesbybridgewater.com
(843) 422-7778
HOMEOWNER SIGNATURE &
DATE OF ACCEPTANCE REVISION DATE BOUNDARY STREET TOWNHOMES #1 TO #4 RESIDENCE
1010 BOUNDARY STREET
BEAUFORT, SOUTH CAROLINA
CROSS SECTION
SCALE 1/4" = 1' - 0"
SHEET
9/22/2026
REND
SVC
YARD
~19'-2
1 8"
~19'-2
1 8"
SQUARE FOOTAGE
FIRST FLOOR 592 SQFT
SECOND FLOOR 520 SQFT
PORCHES (SCREENED) 56 SQFT
AREA OF ADDITION 628 SQFT
AREA OF ADDITION 598 SQFT
AREA OF ADDITION 592 SQFT
AREA OF ADDITION 302 SQFT
AREA OF ADDITION 160 SQFT
AREA OF ADDITION 64 SQFT
19.09
BRIDGEWATER CONSULTING LLC
BEAUFORT, SOUTH CAROLINA
nschoen@homesbybridgewater.com
(843) 422-7778
HOMEOWNER SIGNATURE &
DATE OF ACCEPTANCE REVISION DATE BOUNDARY STREET TOWNHOMES #1 TO #4 RESIDENCE
1010 BOUNDARY STREET
BEAUFORT, SOUTH CAROLINA
PROJECT RENDERINGS
NOT TO SCALE
*THIS IS A CONCEPT ONLY, NOT MEANT AS CONSTRUCTION DRAWINGS
SHEET
9/22/2026
XX
SVC
YARD
~19'-2
1 8"
~19'-2
1 8"
SQUARE FOOTAGE
FIRST FLOOR 592 SQFT
SECOND FLOOR 520 SQFT
PORCHES (SCREENED) 56 SQFT
AREA OF ADDITION 628 SQFT
AREA OF ADDITION 598 SQFT
AREA OF ADDITION 592 SQFT
AREA OF ADDITION 302 SQFT
AREA OF ADDITION 160 SQFT
AREA OF ADDITION 64 SQFT
19.09
DN
STACK
W/D
18" 18"
DW
30"
SINK
36" VANITY
24"
18" 18"
DW
30"
SINK
36" VANITY
24"
30" RANGE
36" FRIDGE
VERIFY SWING
CLEARANCE
SHELF
15"15"
48"
UP UP
FIREPROOF
ELDH3672E
~98" HDR HGT
FIREPROOF
ELDH3672E
~98" HDR HGT
2480
3080 CO
ELDH3672E
~98" HDR HGT
ELDH3672E
~98" HDR HGT
ELDH3672E
~98" HDR HGT
ELDH3672E
~98" HDR HGT
3068 LHIS w/ DS TRANS
~98" HDR HGT
ELDH3672E
~98" HDR HGT
3080
UP
7' 3'-8" 4'-7" 3'-9"
1' 1'
8'-9 1 2"
34'
2' 4'-6"
2'-4 1 2"
3'-4 1 2" 3'-9" 6'
5 1 2"
4'-3 1 2" 2'-3" 10' 3'-0 1 2" 3'-6"
5 1 2"
2' 8'
20' 2'
2' 24' 2'
4'-6"2'2'-4"4'
7'-11 1 2"
2'-10 1 2"4'-9"
4'-3 1 2"
3'-1"4'-7"
6'-3"
532 SQ FT
V-GROOVE PINE CLG
8"x8" PT COLUMNS
PT PICKETS @ 3-1/2"o/c
TIMBERTECH T&G DECKING
0-0
LIVING AREA
109" GARAGE
12-3/4" FLOOR SYSTEM
= 121-3/4" TOTAL RISE
7-1/4" RISE = 17 RISERS/16 TREADS
FIREPROOF WALL
DINING
ENTRY
~10' CLG
WOOD FLR
GREAT ROOMKITCHEN
ADJ
BUILDING
ADJ BUILDING
FIREPROOF WALL
COVERED PORCH
DN
30" VANITY
42" VANITY
30" VANITY
42" VANITY
TUB
w/ TILE SURROUND
LINEN
SHLVS
HALF-ROUND GUTTER
w/ DOWNSPOUT
HALF-ROUND GUTTER
w/ DOWNSPOUT
HALF-ROUND GUTTER
w/ DOWNSPOUT
ELDH3672E
~98" HDR HGT
ELDH3672E
~98" HDR HGT
ELDH3672E
~98" HDR HGT
ELDH3672E
~98" HDR HGT
2870
ELDH3672E
~98" HDR HGT
2470
ELDH3672E
~98" HDR HGT
ELDH3672E
~98" HDR HGT
ELDH3672E
~98" HDR HGT
3070
2670
2470
24702470
FRAMELESS
3' 3'-6" 3'-6" 12' 2' 12'-5 1 2"
13'-1"2'-4 1 2"10'-6 1 2"
8'-4 1 2" 5'-4 1 2" 9'-3"
5'-9" 22'
4'-7" 3'-5 1 2" 3'-5 1 2" 11'-6"
6'-5 1 2"2'-10"3'-9 1 2"2'-4 1 2"6'-1 1 2"4'-5"
7' 10' 7' 2'
34'
22'-6 1 2" 22'-5 1 2"
6' ~12'-4 5 8" ~4'-1 7 8"
592 SQ FT
~9' CLG
WOOD FLR
LIVING AREA
~9' CLG
WOOD FLR
BEDROOM #2
TILE
CHASE
FIREPROOF WALL
BEDROOM #1
ZERO
ENTRY TILE
SHWR
TILE
FIREPROOF WALL
ADJ
BUILDING
ADJ BUILDING
BATH #2
BATH #1
GMC
YUKON
BMW
3 SERIES
GMC
YUKON
12"
12" 12"
12"BRICKBRICK
BRICK BRICK
3068
FIBERGLASS
3068
FIBERGLASS
16070 OH
UP
~19'-2
1 8"
~11'-6"
PT 2x: BRICK EXTERIOR
PT 2x: BRICK EXTERIOR
1' 7' 12'
23'
4'-7" 5'-1" 13'-4"
26'
5'-6" 16'
1'-6"
9'-8" 12'-4" 2'
5'-9" 2' 20' 2' 12'-5 1 2"
4'-9" 19'-3" 2' 8'
34'
19' 7'
45'
66 SQ FT
see ENGINEERING for
ALL FOUNDATION
DETAILS
*THIS DRAWING to be USED for
DIMENSIONAL PURPOSES ONLY*
NOTE: ALL DRAIN LINES to
DESCEND TO SLAB BEFORE
RUNNING HORIZONTALLY
ROUGH-IN HORIZONTAL
DRAIN LINES BELOW SLAB!
GARAGE SLAB
~9' CLG
4" TURNDOWN CONC. SLAB
(see ENGINEERING)
o/ VAPOR BARRIER
SLOPE THRU OPENING
*USE KEYWAY ONLY - NO SAW CUTS*
EPOXY FINISH
STREET
VESTIBULE
~8' CLG
DRYWALL
BRICK TILE HERRINGBONE FLR
STREET ENTRY
HERRINGBONE BRICK FLR
LIVING AREA
FIREPROOF WALL
ADJ
BUILDING
ADJ BUILDING
FIREPROOF WALL
1st FLOOR PLAN
SCALE 1/4" = 1' - 0"
BRIDGEWATER CONSULTING LLC
BEAUFORT, SOUTH CAROLINA
nschoen@homesbybridgewater.com
(843) 422-7778
HOMEOWNER SIGNATURE &
DATE OF ACCEPTANCE REVISION DATE BOUNDARY STREET TOWNHOMES #1 TO #4 RESIDENCE
1010 BOUNDARY STREET
BEAUFORT, SOUTH CAROLINA
FOUNDATION PLAN
SCALE 1/4" = 1' - 0"
2nd FLOOR PLAN
SCALE 1/4" = 1' - 0"
PLANTATION MIX
GRAVEL DRIVE
GMC
YUKON
BMW
3 SERIES
GMC
YUKON
12"
12" 12"
12"BRICKBRICK
BRICK BRICK
12"12"BRICK BRICK
12"12"
BRICKBRICK
12"BRICK 12"BRICK12"BRICK
12"
BRICK
12"
BRICK
12"
BRICK
12"BRICK
12"
BRICK
3068
FIBERGLASS
3068
FIBERGLASS
16070 OH
ELDH3672E
~-42 1/4" HDR HGT
ELDH3672E
~-42 1/4" HDR HGT
3068
FIBERGLASS
3068
FIBERGLASS
16070 OH
16070 OH16070 OH
3068
FIBERGLASS
3068
FIBERGLASS
3068
FIBERGLASS
3068
FIBERGLASS
UP
~19'-2
1 8"
~11'-6"
PT 2x: BRICK EXTERIOR
PT 2x: BRICK EXTERIOR
1' 7' 12'
23' 22'-11"
4'-7" 5'-1" 13'-4"
26'
5'-6" 16'
1'-6"
22'
11"
22'
1'-6"
16' 5'-6"
9'-8" 12'-4" 2' 21'
5 1 2"
23'-5 1 2" 22'
5'-9" 2' 20' 2' 12'-5 1 2" 7' 1' 2' 1' 7' 12'-5 1 2" 2' 12'-4" 6'-4"
1'-4"
2'
4'-9" 19'-3" 2' 8'
34'
19' 7'
45'
11"
45'
26'
66 SQ FT
see ENGINEERING for
ALL FOUNDATION
DETAILS
*THIS DRAWING to be USED for
DIMENSIONAL PURPOSES ONLY*
NOTE: ALL DRAIN LINES to
DESCEND TO SLAB BEFORE
RUNNING HORIZONTALLY
ROUGH-IN HORIZONTAL
DRAIN LINES BELOW SLAB!
GARAGE SLAB
~9' CLG
4" TURNDOWN CONC. SLAB
(see ENGINEERING)
o/ VAPOR BARRIER
SLOPE THRU OPENING
*USE KEYWAY ONLY - NO SAW CUTS*
EPOXY FINISH
STREET
VESTIBULE
~8' CLG
DRYWALL
BRICK TILE HERRINGBONE FLR
STREET ENTRY
HERRINGBONE BRICK FLR
LIVING AREA
FIREPROOF WALL
ADJ
BUILDING
ADJ BUILDING
FIREPROOF WALL
FIREPROOF WALL
FIREPROOF WALL
SHEET
9/22/2026
F1.1
SVC
YARD
~19'-2
1 8"
~19'-2
1 8"
SQUARE FOOTAGE
FIRST FLOOR 592 SQFT
SECOND FLOOR 520 SQFT
PORCHES (SCREENED) 56 SQFT
AREA OF ADDITION 628 SQFT
AREA OF ADDITION 598 SQFT
AREA OF ADDITION 592 SQFT
AREA OF ADDITION 302 SQFT
AREA OF ADDITION 160 SQFT
AREA OF ADDITION 64 SQFT
19.09
BRIDGEWATER CONSULTING LLC
BEAUFORT, SOUTH CAROLINA
nschoen@homesbybridgewater.com
(843) 422-7778
HOMEOWNER SIGNATURE &
DATE OF ACCEPTANCE REVISION DATE BOUNDARY STREET TOWNHOMES #1 TO #4 RESIDENCE
1010 BOUNDARY STREET
BEAUFORT, SOUTH CAROLINA
FOUNDATION CONSTRUCTION NOTES
ALL FOUNDATIONS TO COMPLY WITH IRC CHAPTER 4: FOUNDATIONS.
UNDER FLOOR-SPACE VENTILATION IN ACCORDANCE WITH IRC R408.
PROVIDE HYDROSTATIC VENTING PER FLOOD ZONE REQUIREMENTS.
TYPICAL THICKENED SLAB: THICKENED SLAB @ CRITICAL BEARING POINTS TO BE MIN. 1'-0" DEEP x 2'-0"
WIDE CONC., CENTERED ON WALL w/ (2) #5 REINFORCING BARS CONTINUOUS w/ 6x6 WWF (see
ENGINEERING).
TYPICAL REINFORCED CMU WALL FOOTING: TO BE MIN. 1'-0" DEEP x 2'-0" WIDE CONC. w/ (2) #5
REINFORCING BARS AND #5 BARS @ 3'-6" o/c EXTENDING TO MIN. 2'-0" OVERLAP w/ REINFORCING IN
CMU WALL.
TYPICAL REINFORCED CMU WALL: 8" x 8" x 16" CMU BLOCK w/ HORIZONTAL BED REINFORCING @ 8"o/c
AND #5 REINFORCING BARS @ 3'-6" o/c w/ DOWELS TO MATCH (MIN. 2'-0" OVERLAP FROM FOOTING TO
TOP OF CMU WALL) - FILL ALL CELLS.
TYPICAL CONNECTING GRADE BEAM: FOOTINGS @ CONNECTING GRADE BEAM TO BE 12" DEEP x 12"
WIDE CONC. w/ (2) #5 REINFORCING BARS CONTINUOUS.
TYPICAL SLAB ON GRADE: 4" THICK CONC. o/ 6MIL VAPOR BARRIER w/ MIN. 12" x 16" TURNED DOWN
EDGE w/ (2) #5 REINFORCING BARS CONTINUOUS AND 6x6 WWF.
ALL SLABS SHALL HAVE CONTROL JOINTS SPACED 12'-15' APART (MIN): USE KEYWAY ONLY, NO SAW-
CUTS.
TYPICAL REINFORCED CMU PIER FOOTING: TO BE 12" DEEP x DOUBLE THE CMU PIER WIDTH CONC. w/
(2) #5 REINFORCING BARS EACH DIRECTION AND (4 TOTAL) #5 BARS EXTENDING TO MIN. 2'-0" OVERLAP
w/ REINFORCING IN CMU PIER.
TYPICAL REINFORCED CMU PIER: 8"x12"x12 " CMU BLOCK (or 8"x16"x16" CMU BLOCK AS NOTED ON
PLAN) w/ HORIZONTAL BED REINFORCING @ 8" o/c AND (2) TOTAL #5 REINFORCING BARS w/ DOWELS
TO MATCH (MIN. 2'-0" OVERLAP FROM FOOTING TO TOP OF CMU PIER) - FILL ALL CELLS.
NOTE: STRUCTURAL ENGINEERING TO TAKE PRECEDENCE FOR ALL FOUNDATION SIZES,
LOCATION AND PLACEMENT OF WORK DESCRIBED.
FOUNDATION PLAN
SCALE 1/4" = 1' - 0"
DN
STACK
W/D
18" 18"
DW
30"
SINK
36" VANITY
24"
18" 18"
DW
30"
SINK
36" VANITY
24"
30" RANGE
36" FRIDGE
VERIFY SWING
CLEARANCE
SHELF
15"15"
48"
UP UP UP UP
ELDH3672E
~98" HDR HGT
ELDH3672E
~98" HDR HGT
2480
FIREPROOF
ELDH3672E
~98" HDR HGT
FIREPROOF
ELDH3672E
~98" HDR HGT
ELDH3672E
~98" HDR HGT
ELDH3672E
~98" HDR HGT
2480
3080 CO
ELDH3672E
~98" HDR HGT
3068 LHIS w/ DS TRANS
~98" HDR HGT
ELDH3672E
~98" HDR HGT
3068 RHIS w/ DS TRANS
~98" HDR HGT
ELDH3672E
~98" HDR HGT
ELDH3672E
~98" HDR HGT
ELDH3672E
~98" HDR HGT
ELDH3672E
~98" HDR HGT
ELDH3672E
~98" HDR HGT
ELDH3672E
~98" HDR HGT
3068 LHIS w/ DS TRANS
~98" HDR HGT
ELDH3672E
~98" HDR HGT
3080
3068 RHIS w/ DS TRANS
~98" HDR HGT
ELDH3672E
~98" HDR HGT
UP
7' 3'-8" 4'-7" 3'-9"
1' 1'
8'-9 1 2" 3'-8" 7' 4' 7' 14'-5 1 2" 12' 7' 3'
34'
2' 4'-6"
2'-4 1 2"
3'-4 1 2" 3'-9" 6'
5 1 2"
4'-3 1 2" 2'-3" 10' 3'-0 1 2" 3'-6"
5 1 2"
2' 8'
20' 2' 42'-11" 2' 22'
28' 8'
2' 24' 2'
6' 6'
10'24'
4'-6"2'2'-4"4'
7'-11 1 2"
2'-10 1 2"4'-9"
4'-3 1 2"
3'-1"4'-7"
2'
6'-3" 6'-2 1 2" 18' 6'-2 1 2" 6'-3"
532 SQ FT
V-GROOVE PINE CLG
8"x8" PT COLUMNS
PT PICKETS @ 3-1/2"o/c
TIMBERTECH T&G DECKING
0-0
LIVING AREA
109" GARAGE
12-3/4" FLOOR SYSTEM
= 121-3/4" TOTAL RISE
7-1/4" RISE = 17 RISERS/16 TREADS
FIREPROOF WALL
DINING
ENTRY
~10' CLG
WOOD FLR
GREAT ROOMKITCHEN
ADJ
BUILDING
ADJ BUILDING
FIREPROOF WALL
COVERED PORCH
COVERED PORCH
COVERED PORCH
SHEET
9/22/2026
A1.2
1st FLOOR PLAN
SCALE 1/4" = 1' - 0"
SVC
YARD
~19'-2
1 8"
~19'-2
1 8"
SQUARE FOOTAGE
FIRST FLOOR 592 SQFT
SECOND FLOOR 520 SQFT
PORCHES (SCREENED) 56 SQFT
AREA OF ADDITION 628 SQFT
AREA OF ADDITION 598 SQFT
AREA OF ADDITION 592 SQFT
AREA OF ADDITION 302 SQFT
AREA OF ADDITION 160 SQFT
AREA OF ADDITION 64 SQFT
19.09
BRIDGEWATER CONSULTING LLC
BEAUFORT, SOUTH CAROLINA
nschoen@homesbybridgewater.com
(843) 422-7778
HOMEOWNER SIGNATURE &
DATE OF ACCEPTANCE REVISION DATE BOUNDARY STREET TOWNHOMES #1 TO #4 RESIDENCE
1010 BOUNDARY STREET
BEAUFORT, SOUTH CAROLINA
FRAMING CONSTRUCTION NOTES
EXTERIOR WALLS: 1/2" PLYWOOD SHEATHING o/2x4 and/or 2x6 SPF @ 16"o/c w/ BLOCKING MIDSPAN
(UNLESS OTHERWISE NOTED).
INTERIOR WALLS: 2x4 and/or 2x6 SPF @ 16"o/c w/ BLOCKING MIDSPAN (UNLESS OTHERWISE NOTED).
FIRST FLOOR SYSTEM: 2x12 SYP @ 16"o/c w/ 3/4" T&G PLYWOOD (OR EQUIVALENT), GLUED & NAILED.
2nd FLOOR SYSTEM: 14" OPEN WEB TRUSSES (per ENGINEERING) w/ 3/4" T&G PLYWOOD (OR
EQUIVALENT), GLUED & NAILED - ENGINEERED TRUSS SHOP DRAWINGS TAKE PRECEDENCE.
CEILING JOISTS: 2x SYP per ENGINEERING.
ROOF RAFTERS: 1/2" EXT SHEATHING NAILED ON 2x SYP @ 16"o/c (per ENGINEERING) w/ SIMPSON
HURRICANE CLIPS.
NOTE: STRUCTURAL ENGINEERING TO TAKE PRECEDENCE FOR ALL FRAMING MEMBER
SIZES, LOCATION AND PLACEMENT OF WORK DESCRIBED.
DN
30" VANITY
42" VANITY
30" VANITY
42" VANITY
TUB
w/ TILE SURROUND
LINEN
SHLVS
HALF-ROUND GUTTER
w/ DOWNSPOUT
HALF-ROUND GUTTER
w/ DOWNSPOUT
HALF-ROUND GUTTER
w/ DOWNSPOUT
HALF-ROUND GUTTER
w/ DOWNSPOUT
HALF-ROUND GUTTER
w/ DOWNSPOUT
HALF-ROUND GUTTER
w/ DOWNSPOUT
HALF-ROUND GUTTER
w/ DOWNSPOUT
HALF-ROUND GUTTER
w/ DOWNSPOUT
ELDH3672E
~98" HDR HGT
ELDH3672E
~98" HDR HGT
ELDH3672E
~98" HDR HGT
ELDH3672E
~98" HDR HGT
ELDH3672E
~98" HDR HGT
ELDH3672E
~98" HDR HGT
2870
ELDH3672E
~98" HDR HGT
ELDH3672E
~98" HDR HGT
2470
ELDH3672E
~98" HDR HGT
ELDH3672E
~98" HDR HGT
ELDH3672E
~98" HDR HGT
ELDH3672E
~98" HDR HGT
ELDH3672E
~98" HDR HGT
ELDH3672E
~98" HDR HGT
ELDH3672E
~98" HDR HGT
ELDH3672E
~98" HDR HGT
3070
2670
2470
ELDH3672E
~98" HDR HGT
ELDH3672E
~98" HDR HGT
24702470
ELDH3672E
~98" HDR HGT
ELDH3672E
~98" HDR HGT
FRAMELESS
24'
3' 3'-6" 3'-6" 12' 2' 12'-5 1 2" 18' 12'-5 1 2" 2' 12' 7'
13'-1"2'-4 1 2"10'-6 1 2"
8'-4 1 2" 5'-4 1 2" 9'-3"
5'-9" 22' 46'-11"
4'-7" 3'-5 1 2" 3'-5 1 2" 11'-6"
6'-5 1 2"2'-10"3'-9 1 2"2'-4 1 2"6'-1 1 2"4'-5"
7' 10' 7' 2'
34'
22'-6 1 2" 22'-5 1 2"
11"
22'-5 1 2"
6' ~12'-4 5 8" ~4'-1 7 8"
592 SQ FT
~9' CLG
WOOD FLR
LIVING AREA
~9' CLG
WOOD FLR
BEDROOM #2
TILE
CHASE
FIREPROOF WALL
BEDROOM #1
ZERO
ENTRY TILE
SHWR
TILE
FIREPROOF WALL
ADJ
BUILDING
ADJ BUILDING
BATH #2
BATH #1
SHEET
9/22/2026
A1.4
SVC
YARD
~19'-2
1 8"
~19'-2
1 8"
SQUARE FOOTAGE
FIRST FLOOR 592 SQFT
SECOND FLOOR 520 SQFT
PORCHES (SCREENED) 56 SQFT
AREA OF ADDITION 628 SQFT
AREA OF ADDITION 598 SQFT
AREA OF ADDITION 592 SQFT
AREA OF ADDITION 302 SQFT
AREA OF ADDITION 160 SQFT
AREA OF ADDITION 64 SQFT
19.09
BRIDGEWATER CONSULTING LLC
BEAUFORT, SOUTH CAROLINA
nschoen@homesbybridgewater.com
(843) 422-7778
HOMEOWNER SIGNATURE &
DATE OF ACCEPTANCE REVISION DATE BOUNDARY STREET TOWNHOMES #1 TO #4 RESIDENCE
1010 BOUNDARY STREET
BEAUFORT, SOUTH CAROLINA
FRAMING CONSTRUCTION NOTES
EXTERIOR WALLS: 1/2" PLYWOOD SHEATHING o/2x4 and/or 2x6 SPF @ 16"o/c w/ BLOCKING MIDSPAN
(UNLESS OTHERWISE NOTED).
INTERIOR WALLS: 2x4 and/or 2x6 SPF @ 16"o/c w/ BLOCKING MIDSPAN (UNLESS OTHERWISE NOTED).
FIRST FLOOR SYSTEM: 2x12 SYP @ 16"o/c w/ 3/4" T&G PLYWOOD (OR EQUIVALENT), GLUED & NAILED.
2nd FLOOR SYSTEM: 14" OPEN WEB TRUSSES (per ENGINEERING) w/ 3/4" T&G PLYWOOD (OR
EQUIVALENT), GLUED & NAILED - ENGINEERED TRUSS SHOP DRAWINGS TAKE PRECEDENCE.
CEILING JOISTS: 2x SYP per ENGINEERING.
ROOF RAFTERS: 1/2" EXT SHEATHING NAILED ON 2x SYP @ 16"o/c (per ENGINEERING) w/ SIMPSON
HURRICANE CLIPS.
NOTE: STRUCTURAL ENGINEERING TO TAKE PRECEDENCE FOR ALL FRAMING MEMBER
SIZES, LOCATION AND PLACEMENT OF WORK DESCRIBED.
2nd FLOOR PLAN
SCALE 1/4" = 1' - 0"
3 : 12
3 : 123 : 12
3 : 12
3 : 123 : 12
0 : 12
0 : 12
3 : 12
3 : 123 : 12
3 : 12
3 : 123 : 12
0 : 12
0 : 12
0 : 12
0 : 12
0 : 12 0 : 12
0 : 12
0 : 12
0 : 12
0 : 12
0 : 12
0 : 120 : 12
0 : 120 : 12
0 : 12
0 : 12
0 : 12
0 : 12
0 : 12
SHEET
9/22/2026
A1.5
SVC
YARD
~19'-2
1 8"
~19'-2
1 8"
SQUARE FOOTAGE
FIRST FLOOR 592 SQFT
SECOND FLOOR 520 SQFT
PORCHES (SCREENED) 56 SQFT
AREA OF ADDITION 628 SQFT
AREA OF ADDITION 598 SQFT
AREA OF ADDITION 592 SQFT
AREA OF ADDITION 302 SQFT
AREA OF ADDITION 160 SQFT
AREA OF ADDITION 64 SQFT
19.09
BRIDGEWATER CONSULTING LLC
BEAUFORT, SOUTH CAROLINA
nschoen@homesbybridgewater.com
(843) 422-7778
HOMEOWNER SIGNATURE &
DATE OF ACCEPTANCE REVISION DATE BOUNDARY STREET TOWNHOMES #1 TO #4 RESIDENCE
1010 BOUNDARY STREET
BEAUFORT, SOUTH CAROLINA
ROOF PLAN
SCALE 1/4" = 1' - 0"
CORNICE & FASCIA DETAIL
SCALE 3/4" = 1' - 0"
ROOF CONSTRUCTION NOTES
ROOF EAVE DIMENSIONS ARE GENERALLY (UNLESS NOTED OTHERWISE) FROM EXTERIOR SIDE OF
BEARING WALL/BEAM TO FINISHED FACE OF EAVE. see SECTIONS for CLARIFICATION.
EXHAUST VENTS (PLUMBING/HVAC/OTHER) SHALL BE GROUPED IN ATTIC TO LIMIT THE NUMBER OF
ROOF PENETRATIONS.
ALL ROOF PENETRATIONS SHALL BE HIDDEN FROM VIEW AND LOCATED TOWARD THE REAR OF THE
HOUSE (PAINTED TO MATCH ROOF COLOR).
ROOF RAFTERS: 1/2" EXT SHEATHING NAILED ON 2x SYP @ 16"o/c (per ENGINEERING) w/ SIMPSON
HURRICANE CLIPS.
NOTE: STRUCTURAL ENGINEERING TO TAKE PRECEDENCE FOR ALL FRAMING MEMBER
SIZES, LOCATION AND PLACEMENT OF WORK DESCRIBED.
Rendering of Townhome building with units 1 – 4:
Rendering of Townhome building with units 5 – 8:
Rendering of Townhome building s (rear) with units 9 – 12:
Source: City of Beaufort website. First collected Oct 17, 2026.