Planning Commission Regular Meeting — Minutes
City of Beaufort · Beaufort County · Planning Commission · meeting of Aug 17, 2026 · Minutes
Open the original document More from City of Beaufort
Text
Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.
1
Planning Commission
Regular Meeting Minutes – August 17, 2026
CALL TO ORDER 2:32
A regular meeting of the Planning Commission was called to order by Vice-Chairman Bill Bardenwerper
and was held in-person in the Planning Conference Room on August 17, 2026 at 5:02 PM. The meeting
was broadcasted via live-streamed on YouTube. You can view this meeting at the City’s page; City
Beaufort Government.
ATTENDEES
Members in attendance: Bill Bardenwerper, Vice-Chairman Libby Anderson, Secretary, Clinton Hallman,
Kim McFann, and Benjie Morillo.
Absent: Mike Tomy, Chairman and Michael Holle.
Staff in attendance: Curt Freese, Community Development Department Director, Christopher Klement,
Community Development Department Planner III, and Nick Navia, Community Development
Department Planner II.
REVIEW OF MINUTES 2:59
A. June 15, 2026 Worksession Minutes
Ms. Anderson noted the following in the July 15, 2026 Worksession Minutes:
o Page 2, second paragraph, third sentence from the bottom, change the word “of”
before Councilman Scallate to “by”.
o Page 4, delete the fifth line.
Motion: Ms. Anderson made a motion to approve the minutes with the noted changes. Mr.
Morillo seconded the motion. The motion passed unanimously.
B. July 20, 2026 Worksession Minutes
Ms. Anderson noted the following in the July 20, 2026 Worksession Minutes:
o Page 1, under item A, bullet 4, remove the word words.
o Page 2, under item C, second bullet, remove the parentheses after the word against.
2
o Page 4, first paragraph, 1st paragraph, fourth line, change the word to valuation and add
the word assessment, so it reads, valuation assessment.
o Page 4, first paragraph, last sentence add the word Overlay after the Bladen Street.
o Page 4, second paragraph, last sentence, change the word tory to story.
o Page 4, last paragraph, third sentence, add the word District after the word
Redevelopment.
o Page 4, last paragraph, third sentence from the bottom, after the word redevelopment,
add the words infill.
o Page 5, in first the motion, Ms. Anderson did not second the motion, she voted against
the motion and the vote was 6:1, not unanimous.
o Page 5, in the second motion, add the words the motion after the word seconded, so it
reads, Mr. Hallman seconded the motion.
Moton: Mr. Morillo made a motion to approve the minutes with the noted changes. Mr.
Hallman seconded the motion. The motion passed unanimously.
QUESTIONS RELATING TO MILITARY OPERATIONS 0:00
None.
APPLICATIONS 9:45
A. Preliminary Plat and Site Plan - Beaufort Free-Standing Emergency Department (FSED) – 396
Robert Smalls Parkway. The Applicant, Conor Blaney with Ward Edwards is proposing a
commercial development to include a free-standing Emergency Department. The property is
further identified as R120 028 000 1248 0000.
Public Comment:
None.
Closed public comment
Motion: Mr. Hallman made a motion to approve the Preliminary Plat in accordance with the
recommendations in the staff report, pages 4 thru 8:
Staff Findings for Preliminary Plat (in accordance with Development Code Sec. 7.5.4 D and Site
Plan (in accordance with Development Code Sec. 7.5.7 D.3)
1. “The Preliminary Plat is consistent with the rationale and criteria set forth in this Code”:
a. Proposed Land-Use and Land-Development/-Design Compliance according to the specific
Zoning District
Staff analysis:
3
• The latest version of the presented Preliminary Plat includes future lot lines, utility lines
for water, sanitary sewer, and storm drainage as well as any access easements/future ROWs
for new streets to be established on the overall development tract. Hence, as per Section
7.5.4, which states “The purpose of the preliminary plat is to provide the City with an overall
plat and the associated preliminary engineering for the proposed development”, the contents
and the goals for the Preliminary Plat are met.
Moreover,
• For the lot proposed, it is in accordance with Sec. 2.3.3, as per “IC district” zoning,
designed to support institutional uses, such as for hospitals, universities, research facilities,
and offices in a campus-like setting. The proposed “Free-Standing Emergency Department”
(FSED) as part of a future Medical Offices & Health Campus setting, clearly aligns with this
zoning-specific designation.
b. Community Green Space, Open Space and Tree Canopy Areas
Staff analysis:
• In accordance with Code Sec. 5.3.2 (Tree Coverage requirement) and Sec. 7.4.2
(Community Green Space/Open Space requirement), both the revised Site Plan and the
Preliminary Plat show for adequate tree coverage and open space areas for the lot to be
developed but lack any plan for the remainder future lots.
• Specifically, the Preliminary Plat shows a great deal of landscaping and planting of street
trees along new roads and parking lots, which together with the preservation of Specimen/
Landmark trees in the North-West corner (designated Open Space/Park) and within the 50 ft.-
deep highway frontage buffer accrues to 45% of Tree Canopy Coverage Area (min. 30%
required) in Phase 1.
• Also, the Preliminary Plat shows 57,160 square feet (1.3 ac. of Community Green/Open
Space of the overall 7.36 ac. FSED site plan surpassing the requirement of 15% of Community
Green/Open Space as per Sec. 7.4.2 (Table). The specific Green/Open Spaces include a park at
the previously planned “Primary Care Clinic” (PCC) location as well as a park with
Specimen/Landmark trees at the North-West section of the overall tract and existing wetlands
along the norther connector road.
2. “The land use mix within the project conforms to the City’s Development Code and
complies with the Comprehensive Plan and Civic Master Plan”:
a. Consistency according to the City’s Comprehensive Plan (2021)
Staff analysis:
• As per Future Land Use Map (see Appendix A), the current Beaufort Comprehensive Plan
identifies the location of the proposed development as both “Institutional” and part of an
“Urban Center”. Moreover, the concurrent Land Use – Zoning Matrix (see Appendix B), shows
that the “IC” zoning designation is compliant with both the “Urban Center” and “Institutional”
categories. As such, the goal of the “Urban Center” classification, as defined in the 2021
Comprehensive Plan, is “intended to accommodate regional and community businesses (…)”.
4
Under the city’s Needs and Goals of implementing Smart Growth and New Urbanism, the
Comprehensive Plan further specifies to “(…) promote diverse neighborhoods and ensure that
new development is designed for the pedestrian, transit, and the automobile” as well as to be
“(…) committed to mixed-use development that promotes walkability and connectivity (…)”.
(see Land Use Element, Needs and Goads, page LU-6).
b. Compliance with the City’s Civic Master Plan
Staff analysis:
• In Chapter 8.3 of the Civic Master Plan, Robert Smalls Parkway is identified as a “mixed-
use corridor of vibrant activity”. Regarding streetscape improvements, the Civic Plan
recommends “the installation of an off-street multi-use path with a wide landscaped
separation from vehicular travel lanes in order to provide a comfortable, safe and beautiful
option for pedestrian and cyclists.” (Civic Master Plan, page 172 et. seq.).
3. “The utility and transportation design are adequate, given existing and planned capacities
of those systems”:
Staff analysis:
• The Preliminary Plat includes all future lots for the overall Medical Park development
scheme as well as the connection to Charlotte Street (the 4000 Margaret Apartments) the
second primary connection to the site, the southern access road, additional stormwater
ponds, and stormwater management areas, such as a several connected stormwater retention
ponds and swales.
• Also, main water and sewer lines are shown to be provided via the new access road in
between WK Alston Dr. and 4000 Margaret, with sufficient capacity and connections supplied
by “Beaufort Jasper Water & Sewer Authority – BJWSA” through an existing 8-inch water main
located along WK Alston Dr. and a newly built gravity sewer pump station (SP-75) by the new
4000 Margaret community.
a. Scope and Findings of Traffic Impact Analysis (TIA), incl. Supplementary Study from May
15, 2026
Staff analysis:
• Under current capacity and build/no-build impact scenarios within the submitted TIA
study, the surrounding area and intersections between Broad River Road, Robert Smalls
Leadership Academy access drives, WK Alston Drive and particularly the new access road to
the FSED and Medical Offices Campus site with proposed intersection to WK Alson Dr. and the
two proposed RIRO-access points off of SC Hwy 170, were analyzed.
• The recommendations of the January 2026, TIA Report by Kimley-Horn for shown Study
Area (see Study Area Map 1 below) are as follows (Executive Summary):
“Based on the results of the traffic analysis, the proposed Beaufort FSED Development is
anticipated to have impact on the surrounding road network warranting additional turn lanes
as follows:
5
A westbound left-turn lane with 200 ft. of storage at the intersection of WK Alston Dr. and
Broad River Blvd. [indicated as intersection #6 on the Study Map 1]
A northbound left-turn lane with 100 ft. of storage at the intersection of WK Alston Dr. and
Site Access #1 [indicated as intersection #7 on the Study Map 1].”
Map 1: TIA Study Area, January 2026
• The recommendations of the May 15, 2026, Supplementary Study of the TIA Report by
Kimley-Horn for amended Study Area (see Study Area Map 2 below) are as follows
(Summary):
“(…) The analysis supplement is to determine the operations and turn lane warrants if the
Watercrest Apartments are not constructed. The proposed FSED development consists of six
new medical buildings in the northwest quadrant of the intersection of WK Alston Dr. and SC
170 in Beaufort, SC. The anticipated trips generated by the new site are not expected to cause
significant degradations in the LOS of the study area. Therefore, no additional mitigation is
recommended resulting from the analysis.”
4. “Lot layout, including structure, location, and design of each lot”:
FSED – Lot Layout: Preliminary Plat (revised, August 2026) vs. Conceptual Site Plan (April
2026)
Staff analysis:
• Overall lot placement of the FSED building has not changed from last PC Meeting in April
2026, where the main entrance still faces Robert Smalls Parkway (SC Hwy 170) to the south,
and the ambulance drive-thru faces west.
• The FSED-specific parking lots to the south and east of the building, as previously
presented, have been revised and are now generally located to the east and north of the
building (rather than to the south and east). The access to the FSED-building is provided
through a RIRO-ingress/egress point directly from SC Hwy 170 and via the new neighborhood
connector road to the north of the tract. The parking access road on the south side of the
FSED-building is proposed to eventually tie into a neighborhood/connector road that will run
parallel to SC Hwy 170.
5. FSED – Building Design/Architecture:
Most of the previous Staff architect recommendations have been implemented:
• The roof of the ambulance drive-thru was suggested to be a pitched gable roof to be more
in keeping with Lowcountry vernacular.
• Building elevation facing South (SC Hwy 170): the left-hand parapet walls, after being
raised and aligned to same heights all along the building, were suggested to be clad with brick
to simply the overall architectural language, instead of just having the corner elements in
brick. This shall also apply to all other wall sections on the east north and west, that had been
designed to be clad with Hardie Plank siding.
• The vertical windows within the same left-hand parapet wall were recommended to be
shifted vertically above the base water table to match those on the adjacent corner (align all
windows on elevations to be at same height).
6
• Smaller windows on facades and on elevations that face parking lot areas, and which were
not visible from prominent streets or parks, had been recommended to all have similar sizes.
• Subordinate wall sections on the rear and the side of the building that also do not
incorporate any entries/doors had been suggested to be clad in board and batten.
• The courtyard/patio garden that is shown at the south-east corner of the building and
bordered with foundation walls, is recommended to be made directly accessible to the public.
Required elements of a Site Plan as per Sec. 7.5.7 D.3:
a. The plan is consistent with the City of Beaufort Comprehensive Plan and Civic Master Plan.
• See comments from Preliminary Plat.
b. The site plan complies with all applicable requirements of this Code.
• The architecture/building design still needs some minor adjustments to fully comply with
Lowcountry Design Standards (see previous comments on architecture/building design).
c. There exists adequate infrastructure (transportation and utilities) to support the plan as
proposed.
d. The plan conforms to the character of the neighborhood, considering the location, type and
height of buildings or structures and the type and extent of landscaping on the site.
Ms. Anderson seconded the motion. The motion passed unanimously.
Motion: Mr. Morillo made a motion to continue the public hearing to allow staff to review the
new elevations and the applicant is to address any remaining comments from today and to
include the lighting plan at the next meeting. Mr. Hallman seconded the motion. The motion
passed unanimously.
DISCUSSION 1:46:32
A. Comprehensive Plan
The Planning Commission and staff discussed the City of Beaufort Comprehensive Plan.
Public Comment:
Paul Trask, talked about Safe Harbour and asked, “What kind of marina does the City of
Beaufort need for the next 20 – 30 years in downtown Beaufort”? He felt what Safe Harbour
proposed was excessive in terms of mass and scale relative to the Historic District. He referred
to three (3) alternatives: (1) a large destination marina (2) reduced size marina but sourced out
to a third party to operate and manage and (3) a smaller marina focused on local boaters with
appropriate slips provided for transients who are going to support downtown businesses. Mr.
Trask requested that the PC provide a recommendation to City Council to do a formal and
substantial study to determine what kind of marina is appropriate and desired for our city.
Public Comment closed.
7
ADJOURNMENT 2:05:56
Mr. Hallman made a motion to adjourn seconded by Ms. McFann. The meeting ended at 7:05 pm.
Source: City of Beaufort website. First collected Oct 17, 2026.