Planning Commission Regular Meeting Agenda (PDF)
Town of Fort Mill · York County · meeting of Mar 17, 2026 · Agendas
Open the original document More from Town of Fort Mill
Text
Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.
TOWN OF FORT MILL
PLANNING COMMISSION MEETING
March 17, 2026
205 North White Street
6:00 PM
CALL TO ORDER
APPROVAL OF
MINUTES
1. Regular Meeting: February 17, 2026 [Pages 2-6 ]
NEW BUSINESS
1. Commercial Appearance Review: Chick-fil-A [Pages 7-19]
Request fr
om Mark Campbell to grant Commercial Appearance Review approval for the construction of a
new restaurant with a drive-through located at 2325 Azimuth Trail.
ADJOURN
The follo
wing press was notified of the meeting by email or fax in accordance with the Freedom of Information Act:
The Herald, CN2, WRHI, WSOC, and WBTV. The agenda was also posted at the entrance to Town Hall the
required length of time and on the Town website. The Town of Fort Mill is committed to assuring accessibility with
reasonable accommodation, of Town services and facilities for all individuals, in compliance with federal law.
Please contact the Town Manager’s Office at 803-547-2116 if you need assistance.
1
TOWN OF FORT MILL
PLANNING COMMISSION MEETING
February 17, 2026
205 N. White St.
6:00 PM
Present: Chairman Mark Kerr, Vice Chairman Matt Lucarelli, Dan Stout, Sarah Curtis,
Director Penelope Karagounis, Deputy Planning Director Joey Adams -
Raczkowski, Planner Emily Hawkins, Planner Carter Bliss
Absent: Jonathan Hutchinson, Erin Pratt, Daniel Reynolds
Guest: See attached sign-in sheet
C
hairman Mark Kerr called the Planning Commission meeting to order at 6:00 p.m. on Tuesday,
February 17, 2026.
C
hairman Mark Kerr asked for a motion to approve Planning Commission meeting minutes
from January 20, 2026, to be made. Vice Chairman Matt Lucarelli made the motion. Chairman
Mark Kerr seconded the motion. The motion to approve the minutes from January 20, 2025, was
approved by a vote of 4-0.
O
LD BUSINESS
1. Commercial Appearance Review: Unique USA
Deputy Planning Director Joey Adams-Raczkowski gave a brief report of the request from
Patrick Tormeno, to grant Commercial Appearance Review Approval for of The Loom, a 4-
story multifamily building with ground floor retail. The application was deferred from the
January 20, 2026, Planning Commission meeting, and the applicant had brought additional
resources to show changes made based on the Commission’s input.
The previous motion had been to defer based on wanting to see architectural façade changes,
including parking deck elevations and landscaping. Deputy Director Adams-Raczkowski
noted that staff had reviewed all the materials and was again going to defer to the applicant to
present their project, given the scope of the development.
Justin Maxwell, working for BB&M, presented the architectural changes to the Commission.
These changes included added brick, and higher quality materials to enhance the primary
frontages. Additionally, Maxwell introduced parking deck elevations, as well as 3D materials
to assist in visualizing changes. The applicant presented the required landscaping buffer, as
well as the landscaping around the parking deck entrance on Williamson.
One of the changes presented is the use of board-formed architectural concrete, with the
possibility of using the original Mills’ wooden plank floors as the forms, with the end result
2
looking like wood-textured concrete. Another was the use of vinyl-coated chain link fence in
the pen areas of the parking deck.
Vice Chairman Matt Lucarelli questioned the longevity of use of the salvaged wood, citing
experience using board-forms, and their ability or lack thereof to sustain repeated use.
Additionally, the Vice Chairman noted that he was satisfied with the addition of brick
elements to the right side of the south elevation, and that the additional cost will allow the
development to become a prominent feature in our town. Vice Chairman Matt Lucarelli also
sked about the options regarding the black vinyl-coated chain link fence, and if there was a
better-looking option that still met the code perspectives of an open deck. Justin Maxwell
highlighted the placement of the fence on less-exposed areas of the parking deck, and that
they would make sure to present additional designs of chain-link fence for the portions that
would be visible from the street or sidewalk.
Vice Chairman Matt Lucarelli also discussed the importance of plantings and trees around the
parking deck to maximize greenery around the parking deck, providing the nearby residents
with a good visual screen. Planning Director Penelope Karagounis noted that the board had
the option to increase the amount of landscaping if they choose. Additionally, Director
Karagounis noted that if the Board wanted to have something explicitly stated, that they
would need to do so in form of a motion.
Deputy Director Joey Adams-Raczkowski noted that he had reviewed the current landscaping
plan based on the MXU rezoning and approval the applicants went through, as directed by
the Assistant Town Manager, and felt that the landscaping had met the intent of the MXU
rezoning.
Chairman Mark Kerr noted the importance of greenery to not only create a more natural
environment, but also to block out the floodlights of the parking deck. Chairman Kerr asked
about the bleed distance and brightness of the required foot candle on and around the parking
deck. The applicants, Justin Maxwell and Patrick Tormeno, spoke about the height elevation
and the possibility of installing baffles or shields that will project the required light onto the
parking deck, while blocking the light from the residential neighbors across the street.
Commissioner Sarah Curtis asked about the number of canopy trees that would be installed
along that side of the parking deck, noting the dual purpose of both shade and light blockage
that the trees would have.
Jerry Gronske, owner of the development, noted the balance required to both create a safe
environment for users of the parking deck and mitigate light bleeding onto the residential
neighbors.
Patrick Tormeno noted the significance of the height difference between the proposed
parking deck and the neighboring lots across Williamson Street. Mr. Tormeno also noted that
they will be planning on saving a 45-inch oak tree on the other side of Watson Street.
Commissioner Dan Stout asked about the width of the main entrance on Watson Street, and if
it was wide enough for large trucks. Patrick Tormeno noted that the road meets the width
requirement for Fire safety and is 26 feet wide. Commissioner Stout also asked about the
3
type of gates on the parking deck entrances. Mr. Tormeno described the high-speed,
credential-access roller gates that would be used on both entrances.
The board and the applicants discussed the ability to bring samples of the board-formed
concrete and the chain-link fence to the next meeting, or to the Planning staff to review and
discuss with the board members on a separate date. They also discussed the possibility of
deferring only a section of the design elements, and approving specific materials that the
Board agrees on.
Chairman Kerr entertained a motion. Commissioner Sarah Curtis made a motion to recommend
approval of the package with a few conditions: review of the parking deck chain-link fencing,
review of the lighting and photometric plan, and the options to shield lighting across the street,
while also providing enough light to meet code in the parking deck. Commissioner Dan Stout
seconded the motion. By vote of 4-0, the motion to recommend approval of the presented
landscaping package, on the conditions that the parking deck fencing and lighting plan and
fixtures are provided to the Planning Commission for approval.
NEW BUSINESS
1. Commercial Appearance Review: Harris Teeter
Planner Emily Hawkins gave a brief overview of the request Rajeev Bhave, representing
Harris Teeter, to grant Commercial Appearance Review approval for the construction of a
new Harris Teeter Grocery and Pharmacy on 2068 Mary Hinson Court. Ms. Hawkins noted
that the applicant had spoken with the Commission in both November of 2019 and August
2025, and that Mr. Bhave was here to submit a few exterior changes to the front of the
building. Ms. Hawkins noted that the staff recommends a motion of approval, with the
ability for staff to make minor modifications upon submittal.
The board discussed the location of the proposed changes, with the main change being
change of Pharmacy lanes from two to one, and the removal of a canopy on the left side of
the façade, above the home shopping entrance (for employees only).
Rajeev Bhave explained that the plan was originally approved in 2019 without a canopy, and
then in 2025 they revisited the process under the impression that the demand for home
shopping and curbside delivery would be enough to justify a full canopy, but the demand has
subsided, and the canopy has been removed, to revert to the previous 2019 plan.
Chairman Kerr entertained a motion. Vice Chairman Matt Lucarelli made a motion to
recommend Commercial Appearance Review approval upon allowing staff to
administratively approve minor adjustments to the proposed plan to satisfy the comments
and requirements made by staff. Commissioner Sarah Curtis seconded that motion. By vote
of 4-0, the motion to recommend CAR approval upon allowing staff to administratively
approve minor adjustments to the proposed plan, was approved.
4
Chairman Kerr entertained a motion to adjourn. Commissioner Sarah Curtis made a motion
to adjourn. Commissioner Stout seconded that motion. By a vote of 4-0, the motion of
adjournment was approved.
T
he meeting adjourned at 6:47 p.m.
R
espectfully submitted,
Carter Bliss, Planner
February 23, 2026
5
6
Meeting Information
Meeting Type Planning Commission
Meeting Date March 17, 2026
Request Summary
Request Type Action (Old Bus.) X Action (New Bus.) Info/Discussion
Public Hearing Executive Session Other
Case Summary
Case Type Annexation Rezoning Text Amendment
Subdivision Plat X Appearance Review Other
Property Information
Applicant Mark Campbell
Property Owner ARIC Fort Mill, LLC
Property Location 2325 Azimuth Trail
Tax Map Numbers 020-12-01-352
Current Zoning HC, Highway Commercial / COD-N, Corridor Overlay District-Node
Existing Use Vacant
Title
Request from Mark Campbell to grant Commercial Appearance Review approval for the construction
of a new restaurant with a drive-through located at 2325 Azimuth Trail.
Background Information
Site Characteristics The property is located at the corner of Fort Mill Parkway and North Dobys
Bridge Road and is part of the overall Catawba Ridge Market development.
Neighboring Uses Direction Zoning Existing Use
North R-15 Nims Village Subdivision
South HC / COD-N Fort Mill Parkway
East HC / COD-N Vacant
West HC / COD-N Vacant
Zoning Summary The site is currently zoned HC, Highway Commercial and is in the COD -N,
Corridor Overlay District-Node.
7
Dimensional Requirements:
- Maximum building height: 45’
- Minimum front yard setback: 35’
- Minimum side yard setback: 10’
- Minimum rear yard setback: 35’
Parking Requirements (for uses given):
- Total spaces provided: 74 spaces (4 ADA)
- The rear façade of buildings shall not be visible from the corridor and
shall be oriented away from view from the corridor or shall be
screened by landscaped buffers.
- All off-street parking, loading, and service areas shall be screened from
view of the corridor.
Architectural features:
Article II, Section 24(5)(C) of the Zoning Ordinance provides the following
architectural guidelines for the COD-N:
1) Materials:
a. Buildings shall be designed to use building materials such as rock,
stone, brick, stucco, concrete, wood, or Hardiplank.
b. No mirrored glass shall be permitted on any facades in COD -N
and mirrored glass with a reflectance no greater than 20 percent
shall be permitted in COD.
c. Corrugated metal shall not be used in any façade.
2) In COD-N, variations in the rooflines and facades of adjacent buildings
shall be encouraged to avoid monotony.
3) In COD-N, any nonresidential façade facing the corridor or any other
street shall be articulated with architectural features and treatments,
such as windows, awnings, scoring, trim, and changes in materials (i.e.,
stone “water table” base with stucco above), to enhance the quality of
pedestrian environment of the public street, particularly
in the
absence of a primary entrance, so that the façade is of the same quality
and standard of design as if it were the front/primary façade.
Landscape Standards:
- Street trees shall consist of canopy trees planted within the
streetscape zone (the first 15 feet of the setback closest to the
corridor) at rate of one tree per 50 linear feet along all corridor
frontages. Tree spacing shall be not more than 60 feet and not less
than 40 feet on center. At planting, street trees shall be a minimum
of two inches in caliper (measured four feet above ground level) or
eight feet in height.
- All new development or expansions of existing development
resulting in a minimum ten percent increase in building area or lot
area shall provide landscaping within the setback in accordance
with this subsection. For purposes of this subsection, the plantin g
8
area shall be determined by multiplying the lot frontage, less
driveways, times the minimum required setback width to
determine required planting area. Trees: For every 2,500 square
feet of planting area, a minimum of two trees shall be planted . At
least 50 percent of the trees planted to meet this requirement shall
be canopy trees. At planting, required trees shall be a minimum of
two inches in caliper (measured four feet above ground level), and
shall have a mature height of at least 35 feet. Street trees planted
in this area shall be counted toward the minimum tree planting
requirements.
Significant trees protected in accordance with
section 3 of the landscaping standards of article IV may be counted
to satisfy this tree planting requirement. Shrubs: For every 2,500
square feet of planting area, a minimum of ten shrubs shall be
planted. At least 50 percent of the shrubs planted shall be
evergreen.
- Parking areas shall be planted with trees a minimum of two inches
in caliper measured six inches above ground level, so that there is
at least one tree per ten parking spaces within the parking lot. Such
trees shall be adequately staked and protected by curbing against
damage by vehicles. A minimum planting area, equivalent to 18
square feet per tree shall be provided.
- Screening of refuse collection facilities shall provide secure, safe,
and sanitary facilities for the storage and pickup of refuse. Such
facilities shall be convenient to collection and shall be appropriate
to the type 14 and size of use being served. All refuse storage
facilities shall be screened on three sides by a solid wooden fence
or masonry wall and a tight evergreen hedge. The fourth side shall
be angled to minimize the view of the refuse collection facility or
shall be screened by an opaque gate made of durable materials.
The screening shall be of sufficient height and design to effectively
screen the facility from the view of nearby residential uses, streets,
adjacent properties, and recreational facilities.
Applicant Proposal The applicant is seeking Commercial Appearance Review approval for a
new 5,138 sq ft restaurant with a drive -through. Materials are comprised
of brick masonry , prefinished metal coping, and paint. A dumpster
enclosure is also proposed comprised of a single brick claddi ng and
prefinished metal coping to match the proposed building.
Staff
Recommendation
The building plans are currently pending review by Town staff and
generally compl y with all zoning requirements. Staff requests that
Planning Commission evaluate the need for a sidewalk system across the
entirety of the property and the addition of bike racks to promote
pedestrian activity. Should the Planning Commission wish to grant
commercial appearance review approval, staff would request including
language in the approval motion to allow for minor modifications to be
9
made to the plans by staff to include bike racks , a more robust sidewalk
system, and accommodate comments or concerns from reviewing
departments.
Alternatives
1. Grant commercial appearance review approval.
2. Grant commercial appearance review approval with conditions.
3. Deny commercial appearance review approval.
Staff Recommendation
Recommendation
Staff recommends in favor of APPROVAL for the request, conditioned
upon allowing staff to administratively approve minor adjustments to the
proposed plan to satisfy the comments and requirements made by staff.
Name & Title Emily Hawkins, Planner
Department Planning Department
Date of Request 2/23/2026
Legislative History
Planning Commission 3/17/2026: Scheduled
Attachments
• Aerial Map
• Zoning Map
• Commercial Appearance Review Application
• Proposed Elevations
• Proposed Dumpster Enclosure Elevations
• Site Plan
• Landscape Plan
10
Aerial Map
Zoning Map
11
Date Received:
Planning Commission Date:
Fort MiLL
SOUTH CAROLINA
Planning Department
205 White Street
Fort Mill, SC 29715
Phone: 803-835-2337
Commercial Appearance Review Application
General Information
Mark Campbell
Applicant Name:
Applicant Address: 101° Commerce Pr, Bogart, GA 30622
Email:mark@carterengineerin9'com Phone: 770-725-1200
Property Owner Name:
ARIC FORT MILL LLC
Property Owner Address: 2825 S Blvd Ste 300, Charlotte, NC 28209
Email: besmith@astonprop.com phone: 70^~3'I9~4921
Property Information
2325 AZIMUTH TR
Property Address:
Submission Checklist
Completed application
0Full set of elevations with
dimensions
Site plan
Landscape plan
Building material samples
*there is no fee associated with
this application
.Tax Map ID # :
0201201352
Proposed Use: RESTAURANT WITH DRIVE THRU zoning Designation: HC - HIGHWAY COMMERCIAL
Please provide a brief narrative of the proposed scope of work:
PROPOSED RESTAURANT WITH APPROXIMATELY 5,200 SF BUILDING SIZE AND 90 SEATS INTERIOR
AS WELL AS DRIVE THROUGH WITH ASSOCIATED PARKING AND UTILITIES. SITE IS ALSO KNOWN
AS OUTLOT 2 OF THE CATAWBA RIDGE MARKET SUBDIVISION (HARRIS TEETER SHOPPING CENTER)
SITE HAS FRONTAGE ALONG FORT MILL PARKWAY WITH ACCESS VIA AZIMUTH TRAIL INTERNAL
.^
Applicant Signature:,J^^7
*Please submit all materials to Penelope Karagounis at pkaragounis@fortmillsc.gov at least three weeks
prior to the meeting date*
Updated2.13.2026
12
Article V of the Town of Fort Mill Zoning Ordinance outlines the following standards for
Commercial Development Appearance Review:
Sec. 1. - Purpose.
Commercial development appearance review shall be required for all proposed commercial or office development in all
zoning districts except the historic district. Compliance with the requirements for commercial development appearance
review shall be required in addition to the requirements of the underlying zoning district. The purpose of commercial
development appearance review is:
1) To promote Fort Mill's economic viability by encouraging commercial development that enhances the character of the
town;
2) To enhance and protect property values by encouraging excellent design;
3) To encourage architectural freedom, imagination, and variety, and to encourage creative design solutions that will
enhance the town's visual appearance.
Sec. 2. - Definitions.
As used in this section, words and terms shall have the following definitions:
1) Appearance review committee: The municipal committee responsible for ensuring that proposed commercial
development complies with the appearance review standards for proposed commercial development.
2) Proposed commercial development: All new exterior construction or addition which adds square footage associated
with commercial uses except for maintenance, minor repairs, restoration, and temporary structures. Commercial
uses include all retail, business, and office uses.
Sec. 3. - Site plan.
A site plan prepared by a registered engineer or architect shall be submitted for all proposed commercial development.
The site plan shall be drawn to scale and shall be accompanied by a narrative, as appropriate, showing and outlining the
following:
A) Name and address of applicant and site;
B) Scale and north point;
C) Total land area of site in square feet;
D) Property boundaries;
E) Location and dimensions of parking areas;
F) Number of off-street and on-street parking spaces required by regulations and proposed;
G) Location, use, elevations, and dimensions of proposed buildings and buildings within 50 feet of the site boundaries;
H) Location and dimensions of proposed easements, conduits, and rights-of-way;
I) Existing and proposed landscaping and plant materials, including the type, size, number, and spacing of plants;
J) Type, height, and location of night lighting;
K) Location and height of proposed signs; proposed setbacks of signs, elevation of each face of the proposed sign; size
of letters and graphics; colors and frame materials and details;
L) Loading areas and facilities;
M) Pedestrian access;
N) Location, height, and details of walls and fences;
O) Curb cuts;
P) Designation of the kind, color, and texture of all exterior materials.
2
13
Sec. 4. - Appearance review.
1) Commercial development appearance review by the appearance review committee shall be required for all zoning
permits and special exceptions for proposed commercial developments to ensure conformity with the appearance
standards.
2) Applications for commercial development appearance review shall be submitted on an application form obtained from
the zoning administrator. No application shall go before the appearance review committee until the required site plan
and an application fee have been submitted. The amount of the application fee shall be established by the town
council during adoption of the annual budget ordinance.
3) Appearance review committee:
A) The appearance review committee is created.
B) Purpose: The appearance review committee shall be responsible for making recommendations on zoning and
special exception permit applications for proposed commercial development.
C) Membership: The appearance review committee shall consist of the members of the Fort Mill Planning
Commission.
D) Organization:
1) The chairman of the planning commission shall serve as the chairman of the appearance review
committee.
2) The appearance review committee shall operate under the procedures and rules that govern the
actions of the planning commission.
architectural element of the building and site to which it relates.D)The colors, materials, and lighting of every sign shall be
harmonious with the building and site to which it relates.E)The number of graphic elements on a sign shall be held to the
minimum needed to convey the sign's principal message and shall be in proportion to the area of the sign.F)Each sign
shall be compatible with signs on adjoining plots or buildings.G)Corporation logos shall conform to the criteria for all other
signs.6)Miscellaneous structures: Miscellaneous structures and hardware shall be part of the architectural concept of the
project. Materials, scale, and colors shall be compatible with the building and surrounding uses.
3
14
Sec. 5. - Appearance standards.
1) Relationship of building site:
A) The proposed commercial development shall be designed and sited to accomplish a desirable view as
observed from adjacent streets.
B) Parking areas shall be enhanced with decorative elements, building wall extensions, plantings, berms, or
other innovative means to screen parking areas from view from the streets.
C) Utility services shall be underground.
2) Relationship to adjoining areas:
A) Adjacent buildings of different architectural styles shall be made compatible by use of screens, sight
breaks, materials, and other methods.
B) Landscaping shall provide a transition to adjoining property.
C) Texture, building lines, and mass shall be harmonious with adjoining property. Monotonous texture,
lines, and mass shall be avoided.
3) Landscaping: Landscaping shall conform to article IV and other sections of this ordinance.
4) Building design:
A) Architectural style is not restricted. Quality of design and compatibility with surrounding uses shall
provide the basis of the evaluation of the appearance of a proposed commercial development.
B) Materials shall be of good architectural character and shall be harmonious with adjoining
buildings.
C) Materials shall be suitable for the type and design of the building. Materials which are
architecturally harmonious shall be used for all exterior building walls and other exterior building
components.
D) Materials and finishes shall be of durable quality.
E) Building components, such as windows, doors, eaves, and parapets, shall have appropriate proportion and
relationships to one another.
F) Colors shall be harmonious and shall use compatible accents.
G) Mechanical equipment or other utility hardware on roof, ground, or buildings shall be screened from view
with materials harmonious with the building.
H) Monotony of design shall be avoided. Variation in vegetation, detail, form, and siting shall be used to
provide visual interest.
5) Signs:
A) Signs shall conform to the provisions of article III and this article.
B) Every sign shall be of appropriate scale and proportion in relation to the surrounding buildings.
C) Every sign shall be designed as an integral
6) Miscellaneous structures: Miscellaneous structures and hardware shall be part of the architectural concept of the
project. Materials, scale, and colors shall be compatible with the building and surrounding uses.
4
15
CANOPY NOTES:
BUILDING MOUNTED CANOPIES - 8" THICK CANOPY
- KYNAR FINISH OF STRUCTURE, FASCIA, &
DECKING TO MATCH
COLUMN MOUNTED CANOPIES - 10" THICK CANOPY
- FINISH OF STRUCTURE TO BE
- FINISH OF DECKING TO BE
CP-1
CP-2
CP-1
GENERAL NOTES
1. ALL SIGNAGE PROVIDED BY OTHERS
2. REF FLOOR PLAN AND WINDOW LEGEND FOR STOREFRONT INFORMATION
3. DARPRO EXTRACTION PORT 40' MAX TO TRUCK ACCESS, RE: PLUMBING
C4-B
T/ HIGH PLATE 22' - 0"
T/ LOW PLATE 21' - 6 1/2"
T/ SOLDIER 13' - 0"
B/ CANOPY 9' - 8"
WATER TABLE 3' - 0"
T/ SLAB 0' - 0"
C/ SCONCE 8' - 0"
4'-8" 5'-9 1/8" 6'-0" 7'-7 1/2" 6'-0" 13'-0 1/2" 3'-4 1/2" 5'-2 5/8" 7 3/8" 4'-4" 6'-3" 6'-0" 1'-2" 6'-0" 1'-3 5/8" 2'-7" 2'-3 7/8" 1'-0 1/8"
4'-8" 47'-0 1/4" 25'-8" 2'-7" 3'-4" 29'-6"
83'-3 1/4"
32'-8"
C4-LC3-C
T/ HIGH PLATE 22' - 0"
T/ LOW PLATE 21' - 6 1/2"
T/ SOLDIER 13' - 0"
B/ CANOPY 9' - 8"
C/ SCONCE 8' - 0"
WATER TABLE 3' - 0"
T/ SLAB 0' - 0"
10'-2"
EQ EQ
12'-8 3/4"2'-5 5/8"6'-0"4'-5 3/4"6'-4"4'-6 1/4"6'-0"2'-6 1/8"4 5/8"3'-4 1/2"8'-1 1/4"3'-4 1/2"2 1/8"3'-0 5/8"6'-0"3'-1 1/2"6'-0"1'-3 3/8"3'-4 1/4"
29'-6" 3'-4 1/4" 19'-5 1/2" 15'-5" 32'-3 3/4" 12'-8 3/4"
83'-3 1/4"
32'-8"
T/ HIGH PLATE 22' - 0"
T/ LOW PLATE 21' - 6 1/2"
T/ SOLDIER 13' - 0"
B/ CANOPY 9' - 8"
C/ SCONCE 8' - 0"
WATER TABLE 3' - 0"
T/ SLAB 0' - 0"
6'-8 1/2" 6'-0" 4'-8" 6'-0" 4'-8" 6'-0" 10'-2" 3'-4 1/2" 1'-6 1/8" 5'-4 5/8" 6'-0" 6'-3 7/8"
5 1/8" 49'-1 1/8" 17'-8 1/2"
67'-3 1/4"
T/ HIGH PLATE 22' - 0"
T/ LOW PLATE 21' - 6 1/2"
T/ SOLDIER 13' - 0"
T/ SOLDIER +/- 11' - 3"
B/ CANOPY 9' - 8"
WATER TABLE 3' - 0"
T/ SLAB 0' - 0"
6'-8" 3'-0" 2'-9 3/4" 32'-8 1/4" 23'-7 1/4" 3'-11"
60'-5"
6'-8" 3'-0" 35'-6" 23'-7 1/4"
EXTERIOR FINISHES
PREFINISHED METAL COPING
COLOR: MIDNIGHT BRONZE
BRICK VENEER
COLOR: GLEN GERY - COURTLAND
SIZE: MODULAR
EXTERIOR PAINT
COLOR: DARK BRONZE
FINISH: SEMI-GLOSS
STOREFRONT
COLOR: DARK BRONZE
BRICK VENEER
COLOR: GLEN GERY - WHITEHALL
SIZE: MODULAR
BR-A
BR-B
EC-1
PT-113
ST-1
Chick-fil-A
5200 Buffington Road
Atlanta, Georgia
30349-2998
Information contained on this drawing and in all digital files
produced for above named project may not be reproduced in
any manner without express written or verbal consent from
authorized project representatives.
CONSULTANT PROJECT #
PRINTED FOR
DATE
SHEET
SHEET NUMBER
DRAWN BY
REVISION SCHEDULE
A
1 2 34
B
C
D
E
A
B
C
D
E
1234
CHICK-FIL-A
BUILDING TYPE / SIZE:
RELEASE:
#
3/5/2026 10:21:35 AM Autodesk Docs://SC_05201_Dobys Bridge FSU_2026.1_FSR/05201_Dobys Bridge FSU_ARC.rvt
A-302
COLOR ELEVATIONS
DESIGN
02/19/2026
Author
DOBYS BRIDGE FSU
05201
FORT MILL PKWY
FORT MILL, SC 29715
10-SE-05201-A-302-COLOR ELEVATIONS
CFSC05201
25.10
P14 SE BASE
FSR
FINISH SCHEDULE - EXTERIOR
MAR
K DESCRIPTION MANUFACTURER MODEL NAME
MODE
L
NUMBER COLOR SIZE NOTE
BR-A BRICK VENEER (PRIMARY) GLEN GERY COURTLAND * COURTLAND MODULAR BRICK SELECTIONS HAVE BEEN
APPROVED BY CFA AND CITY REVIEW.
NO SUBSTITUTIONS WITHOUT PRIOR
APPROVAL. MORTAR TYPICAL ARGOS,
SAN TAN
BR-B BRICK VENEER (ACCENT) GLEN GERY WHITEHALL * WHITEHALL MODULAR BRICK SELECTIONS HAVE BEEN
APPROVED BY CFA AND CITY REVIEW.
NO SUBSTITUTIONS WITHOUT PRIOR
APPROVAL. MORTAR TYPICAL ARGOS,
SAN TAN
CP-1 CANOPY METAL FASCIA DURA COAT DC19ST-2703 DARK BRONZE OIL RUBBED BRONZE METALLIC
TEXTURE PVD
CP-2 CANOPY METAL DECK WHITE SMOOTH WHITE, HIGH GLOSS
EC-1 PARAPET WALL COPING DUROLAST /
EXCEPTIONAL METALS
MIDNIGHT
BRONZE
PT-100 EXTERIOR PAINT SHERWIN WILLIAMS SHER-CRYL HIGH PERFORMANCE
ACRYLIC #B66-350
SW 2807 ROOKWOOD REFUSE ENCLOSURE. FINISH:
SEMI-GLOSS ON DOOR FRAMES,
SATIN ON WALLS
PT-113 EXTERIOR PAINT SHERWIN WILLIAMS SHER-CRYL HIGH PERFORMANCE
ACRYLIC #B66-350
SW
BRONZETONE
DARK BRONZE FINISH: SEMI-GLOSS EXTERIOR
METALS
ST-1 STOREFRONT YKK YES 45 DARK BRONZE
(MATTE)
E+H ARCHITECTS P.C.
750 OLD HICKORY BLVD. SUITE 150-2
BRENTWOOD, TN 37027
PHONE: 615.377.3111
EMAIL: CFATEAM@EANDHARCH.COM
March 12, 2026
1/4" = 1'-0"
EXTERIOR ELEVATION
D4
1/4" = 1'-0"
EXTERIOR ELEVATION
C4
1/4" = 1'-0"
EXTERIOR ELEVATION
B4
1/4" = 1'-0"
EXTERIOR ELEVATION
A4
NO. DATE DESCRIPTION
03/12/2026 IFP
16
16 GA FORM DECK PANELS
WELDED TO FRAME - PAINT
GATE PULLS AS APPROVED
BY OWNER.
STEEL PLATE AND ANCHORAGE
1" DIAMETER STEEL DROP ROD
1-1/4" DIAMETER DRILLED HOLE
IN CONCRETE DRIVE.
STEEL BENT CLIP BOLTED TO
STEEL MAIN FRAME - PAINT
6" LONG DROP ROD GUIDE
VERTICAL EDGE OF CONCRETE SLAB
BEHIND & BELOW GATE
CONCRETE DRIVE - RE: CIVIL
GRAY INDICATES PAINT PT-9 IN
THIS DRAWING, TYP
1/2" EXPANSION JOINT - RE: CIVIL
PT-113
PT-113
PT-113
9 3/4"
6" PIPE BOLLARD GATE
POST BEYOND - PAINT
1/2" EXPANSION
JOINT - RE: CIVIL
CONCRETE PAVING
- RE: CIVIL
6" MIN. CRUSHED
STONE BASE
POST FOUNDATION
- RE: STRUCTURAL
CONCRETE SLAB & FOOTING
(RE: STRUCTURAL)
SLOPE FOR DRAINAGE - RE: PLAN
1" CHAMFERED EDGE
GATE PANEL
STORAGE RM FLOOR
0'-6"
PT-113
TOP OF GRADE
0'-0"
GROUT CAVITY SOLID AT
BELOW FLASHING
LINE OF FINISHED GRADE - RE: CIVIL
CONT. MEMBRANE FLASHING
WITH WEEP HOLES AT 32" O.C.
GROUT BOTTOM TWO
COURSES SOLID, TYP AND
EXTEND GROUTING
DOWNWARD INTO FOOTING
AS SHOWN ON
STRUCTURAL DRAWINGSBRICK VENEER
HORIZONTAL JOINT
REINFORCEMENT WITH HOOK &
EYE TYPE BRICK TIES
- RE: STRUCTURAL
EXTEND BRICK VENEER TO
FOOTING BELOW.
CONTRACTOR SHALL HAVE
OPTION TO USE 4" THICK
CMU INSTEAD OF BRICK AT
AREAS BELOW FINISH
GRADE.
CONCRETE SLAB,
RE: STRUCT.
FOOTING - RE: STRUCTURAL
LEVEL 1
0'-0"
1/2" EXPANSION JOINT
AIR SPACE
DAMPPROOFING
1'-0"
H.M. DOOR PAINT
PAINTED HOLLOW METAL
DOOR & FRAME
CONCRETE FILLED &
REINFORCED CELL
RE: STRUCTURAL
SEALANT, TYP ALL SIDES
3 ANCHORS PER JAMB
GROUT SOLID
8" CMU
PT-100
SLOPE
DECKING
- RE: STRUCTURAL
RAFTERS
- RE: STRUCTURAL
BOND BEAM
- RE: STRUCTURAL
8" HARDIE PLANK
2X BLOCKING
2-PIECE METAL DRIP EDGE
DARK BRONZE
10 D NAILS AT 6" O.C.ROOFING MEMBRANE
JOIST
ANCHORAGE - RE:
STRUCTURAL
HORIZONTAL JOINT
REINFORCEMENT
- RE: STRUCTURAL
7'-4" A.F.F.
2X TREATED TOP PLATE
RE: STRUCTURAL FOR
ANCHORAGE
PT-31A
PREFINISHED METAL COPING
(DARK BRONZE)
2X8 TREATED TOP PLATE
CONTINUOUS CLEAT RE:
STRUCTURAL FOR ANCHORAGE
BOND BEAM - RE: STRUCTURAL
BRICK VENEER
1/2" CDX PLYWOOD
CEILING - PAINT
RAFTERS - RE: STRUCTURAL
ANCHORAGE
- RE: STRUCTURAL
ROOF DECKING
- RE: STRUCTURAL
SINGLE-PLY PVC ROOF
MEMBRANE, RE: A-905
SS SCREWS WITH NEOPRENE
WASHER AT 48" O.C.
SLOPE
HORIZONTAL JOINT
REINFORCEMENT WITH HOOK
& EYE TYPE BRICK TIES
- RE: STRUCTURAL
MOISTURE BARRIER
PAINT, SEALANT, TYP
ALL SIDES
PAINTED HOLLOW METAL DOOR
& FRAME,
RE: DOOR SCHEDULE
GROUT SOLID
DRIP CAP CMU BOND BEAM
- RE: STRUCTURAL
BACKER ROD &
SEALANT
WEEPS AT 24" O.C.
7'-4" A.F.F.
LINTEL RE: STRUCTURAL
REFUSE ENCLOSURE NOTES
1. ** IN THE ARCHITECTURAL DRAWINGS, REFUSE ENCLOSURE AND MAIN
BUILDING MAY BE NOTED WITH FINISH SLAB AT 0'-0". ACTUAL FINISH SLAB
HEIGHTS WILL VARY BETWEEN MAIN BUILDING AND REFUSE ENCLOSURE.
REFER TO CIVIL FOR ALL FINISH SLAB HEIGHTS.
REF. ENCLOSURE
FINISHES
PREFINISHED METAL COPING
COLOR: MIDNIGHT BRONZE
BR-A
EC-1
BRICK VENEER
COLOR: GLEN GERY - COURTLAND
SIZE: MODULAR
C2
A-103
6" DIAMETER
STEEL PIPE
GATE POST
PIPE BOLLARDS
RE: CIVIL
HYDRANT -
RE: PLUMBING
RE: KITCHEN
FOR SHELVING
IN THIS AREA. STORAGE
REFUSE
12' - 3 1/2" 9" 12' - 3 1/2" 8' - 4"
1' - 0"6' - 8 3/8"7 5/8"25' - 4"1' - 0"
34' - 8"
4' - 4"4' - 0"8' - 8"4' - 0"4' - 4"
1' - 0" 8' - 8" 1' - 0"
10' - 8"LOW PROFILE TURBINE
ROOF VENTILATOR
EQUAL TO MASTER FLOW
12" GALVANIZED STEEL
INTERNALLY BRACED
DUAL-BEARING ROOF
TURBINE IN WEATHERED
WOOD FINISH PROVIDED
AND INSTALLED BY GC.
COORDINATE WITH
ROOFING SYSTEM FOR
WEATHERTIGHT
INSTALLATION.
6" 12'-5" 4 1/2" 4 1/2" 12'-5"
RAMP TO DOOR
MAX SLOPE 1:1251
4'-0" UNISTRUTS,
TYP.
9 3/4"
9 3/4"
SAW CUT -
RE: CIVIL
8"x16" WALL
DRAIN OPENING
BELOW
1/4" / 1'-0"
0' - 6"
0' - 6"
0' - 3 3/8"
0' - 6"
0' - 6"
T/ PAD
T/ PAVING
(SEE SECTION)
0' - 6"
T/ PAD
T/ PAVING
(SEE SECTION)
1/4" / 1'-0"
1/4" / 1'-0"
0' - 6" 0' - 6"
0' - 6"
0' - 6"
1'-0 1/2"
A2
A-103
B2
A-103
B1
A-103
C2
A-103A
A2
A-103A
B2
A-103A
B1
A-103A
A-103
E3
STORAGEREFUSE
WHITE ROOFING MEMBRANE
ON ROOF DECKING - RE: STRUCTURAL
ON RAFTERS - RE: STRUCTURAL
ON 1/2" CDX PLYWOOD CEILING -
PAINT
WHITE ROOFING MEMBRANE
AT WALL BEYOND
1/2" EXPANSION JOINT -
RE: STRUCTURAL
CONCRETE SLAB - RE: STRUCTURAL
CONCRETE SLAB -
RE: STRUCTURAL FOR
SEAL SPECIFICATIONS
BLOCK FILLER WITH ONE
COAT OF PRIMER & ONE
COAT EPOXY PAINT TO
MATCH BRICK.
BOLLARD - RE: CIVIL
INSTALL 4'-0" LENGTH OF
UNISTRUT VERTICALLY
BEHIND EACH BOLLARD -
PAINT TO MATCH
ADJACENT WALL
9' - 2"
7' - 10"
0' - 6"
T/ EXTERIOR BOND BEAM
T/ INTERIOR BOND BEAM
T/ SLAB
TOP OF UNISTRUT SHALL BE FLUSH WITH BOTTOM
OF DRIP EDGE AT INSIDE FACE OF METAL CAP
TERMINATION BAR AT
EXPOSED EDGE
PT-31A
A-103
E2
A-103
C3
A-103
A3
D2
A-103
_____________________
D3
A-103
_____________________
C4
A-103
_____________________
T/ GRADE 0' - 0"
BR-A
T/ EXTERIOR BOND BEAM 9' - 2"
T/ INTERIOR BOND BEAM 7' - 10"
T/ SLAB 0' - 6"
T/ EXTERIOR BOND BEAM 9' - 2"
T/ INTERIOR BOND BEAM 7' - 10"
BR-A
T/ SLAB 0' - 6"
T/ GRADE 0' - 0"
PAINTED STEEL POST CAPS (TYP)
PAINT
COLLAR HINGES (TAP & ADD
GREASE FITTINGS AT EACH
HINGE-GREASE HINGES AFTER
PAINTING)
2-1/2" X 2-1/2" PAINTED STEEL
TUBE GATE FRAME - PAINT
6" DIAMETER PAINTED STEEL
POST - PAINT
1-1/2" X 1-1/2" PAINTED STEEL
ANGLES - PAINT
16 GA FORM DECK PANELS
WELDED TO FRAME - PAINT
DROP RODS BEYOND
2 EQUAL PANELS
11'-7"
12'-5"
PT-113
PT-113
PT-113
PT-113
T/ GRADE 0' - 0"
Chick-fil-A
5200 Buffington Road
Atlanta, Georgia
30349-2998
Information contained on this drawing and in all digital files
produced for above named project may not be reproduced in
any manner without express written or verbal consent from
authorized project representatives.
CONSULTANT PROJECT #
PRINTED FOR
DATE
SHEET
SHEET NUMBER
DRAWN BY
REVISION SCHEDULE
A
1 2 34
B
C
D
E
A
B
C
D
E
1234
CHICK-FIL-A
BUILDING TYPE / SIZE:
RELEASE:
#
3/10/2026 11:21:17 AM Autodesk Docs://SC_05201_Dobys Bridge FSU_2026.1_FSR/05201_Dobys Bridge FSU_ARC.rvt
A-103A
REFUSE ENCLOSURE
COLOR
DESIGN
02/19/2026
Author
DOBYS BRIDGE FSU
05201
FORT MILL PKWY
FORT MILL, SC 29715
10-SE-05201-A-103A-REFUSE ENCLOSURE COLOR
CFSC05201
25.10
P14 SE BASE
FSR
E+H ARCHITECTS P.C.
750 OLD HICKORY BLVD. SUITE 150-2
BRENTWOOD, TN 37027
PHONE: 615.377.3111
EMAIL: CFATEAM@EANDHARCH.COM
March 12, 2026
1/2" = 1'-0"
REFUSE ENCOSURE DROP ROD 3-D DECK PANEL DETAIL
A3
3/4" = 1'-0"
REFUSE PAD AT CONCRETE PAVING DETAIL
C4 1 1/2" = 1'-0"
REFUSE ENCLOSURE BASE DETAIL
C3
1 1/2" = 1'-0"
REFUSE ENCLOSURE DOOR JAMB DETAIL
D2
1 1/2" = 1'-0"
REFUSE ENCLOSURE DRIP EDGE
E21 1/2" = 1'-0"
REFUSE ENCLOSURE ROOF EDGE DETAIL
E3
1 1/2" = 1'-0"
REFUSE ENCLOSURE DOOR HEAD DETAIL
D3 1/4" = 1'-0"
REFUSE ENCLOSURE PLAN
D1
1/2" = 1'-0"
REFUSE ENCLOSURE SECTION
C2
3/8" = 1'-0"
REFUSE ENCLOSURE ELEVATION
A2
3/8" = 1'-0"
REFUSE ENCLOSURE ELEVATION
B2 3/8" = 1'-0"
REFUSE ENCLOSURE GATE REAR ELEVATION
B1
PERSPECTIVE VIEW - REFUSE ENCLOSURE
NO. DATE DESCRIPTION
03/12/2026 IFP
17
7
9
8
DO NOT ENTER
DRIVE
THRU DRIVE
THRU
ONE-WAY
ONE-WAY
24.0'
18.0' 25.0'
8.0'
36.7'
25.0'
35.0'
27.6'
24.6'
43.9'
16.7'
312'
204'
ONE-WAY
ONE-WAY
ONLY
P14-SE-BASE - 5,183 SF
90 SEATS (INTERIOR)
16 SEATS (EXTERIOR
74 PARKS
FFE = 657.50
7
5
14.5'
9.9'
24.0'
22.3'
25.0'
18.0'
18.0'
18.0'
9.0'
9.0'
9.0'
9.0'9.0'
7 3
18.0' 18.0'
9 6
10.0'
8
FORT MILL PARKWAY
(VARIABLE R/W)
PUBLIC R/W
N 05°14'42" W
228.71'
S 87°22'55" E
246.27'
N 83°25'50" E
83.05'
S 03°19'47" E
39.66'
S 14°09'11" E
113.40'
CURVE RADIUS ARC LENGTH CHORD LENGTH CHORD BEARING DELTA ANGLE TANGENT
C1 2910.00' 430.08' 429.69'S 85°47'17" W 8°28'05" 215.43'
C2 509.30' 78.33' 78.25'N 88°16'30" E 8°48'43" 39.24'
C3 5210.27' 38.82' 38.82'S 15°33'13" E 0°25'37" 19.41'
C1
C2
LINE BEARING DISTANCE
L1 S 12°55'19" E 10.09'
L1
C3
5' SETBACK
35' SETBACK
10' SETBACK
(PRIVATE DRIVE)
(PRIVATE DRIVE)
EX. GUARD RAIL
30.0'
9.0' 9.0' 8.0' 9.0' 9.0'
5
5.0' 9.0'
18.0'
26.9'
10.0'
10.0'
SIDEWALK PROPOSED BY
OVERALL DEVELOPER
SIDEWALK PROPOSED BY
OVERALL DEVELOPER
1
1
1
1
1
12 1
1
3
3
4
4
4
4
5
5
5
5
5A
5A
5A
5A
5A
5A
5B
5B
5B
5B
6A/6H
6A/6H
1
6A
6B
20
6B
20
6B
20
6B
20
PROP. RAMP FOR
TRASH ROUTE
7
7
PROP. LEVEL LANDING
6H
11
11
11
11
17
17
17
17
17
17
17
17
17
17C17D
19
21B
21B
21B
21B
21B
21B
21B
21B
21B
24
25
25
25
33
35
34
35
34
36
36
39
39
39
39
39
39
39
39
3939
39
39
39
39
40
58
58
58
58
58
41
45A
45A
45A
45A
49
50
53
55
41
41
41
20' WATER EASEMENT
DO NOT ENTER
DO NOT ENTER
6A/6H
45
45
36
20
20
60A
60A
DO NOT ENTER
R15.0'
R3.0'
R15.0'
R3.0'
R3.0'
R3.0'
R15.0' R15.0'
R15.0'
R3.5'
R5.0'
R3.0'
R3.0'
R3.0'
R3.0'R3.0'
R10.0'
R3.0'
R3.0'
R3.0'
R15.0'
R15.0'
R12.0'
R3.0'
R8.0'
R3.0'
R22.0'
R3.0'
R3.0'
R3.0'
R15.0'
R20.0'
R3269.0'R2874.5'
R20.0'
R3.5'
R3.0'
R3.0'
R20.0'
R24.0'
R18.0'
R29.0'
R8.0'
33
PROP. CASH CART
PROP. 5' CROSSWALK
PROP. 3' CROSSWALK
12
2.0'10.0'
3.0'10.0'
25.0'
7
52
17D
24.4'
C-2.1
SITE PLAN
1-2026
GRID NORTH
20'
GRAPHIC SCALE
0
SCALE: 1" = 20'
10'20'40'60'
REVISION BLOCK
ISSUE REVISION DATE & DESCRIPTION
1 01/13/26 - PCR
2 02/10/26 - COMMENTS ADDRESSED
3 -
4 -
5 -
6 -
7 -
ENGINEER/DESIGNER NOT RESPONSIBLE FOR COST CHANGES DURING PRELIMINARY PHASE. BIDS & QUOTES SHALL BE BASED ON PLAN SETS LABELED "ISSUE FOR BID". BIDS & QUOTES SHALL BE REVISED BASED ON PLANS LABELED "ISSUE FOR CONSTRUCTION".
C I V I L E N G I N E E R I N G | L A N D S C A P E A R C H I T E C T U R E | L A N D P L A N N I N G | L A N D S U R V E Y I N G | M U N I C I P A L S E R V I C E S
COPYRIGHT CARTER ENGINEERING CONSULTANTS, INC. ALL RIGHTS RESERVED. NO PART OF THIS DOCUMENT MAY BE REPRODUCED IN ANY FORM OR FASHION OR BY ANY MEANS WITHOUT PRIOR CONSENT, AGREEMENT AND WRITTEN PERMISSION FROM CARTER ENGINEERING CONSULTANTS, INC.
22028CFA
02/02/2025
OUTLOT 2, FORT MILL PARKWAY,
FORT MILL, SC 29715
Sheet
Job No.
Date
Store
1-2026
STORE #05201
#05201
CARTER ENGINEERING
1010 COMMERCE DR.
BOGART, GA. 30622
P: 770.725.1200
F: 770.725.1204
www.carterengineering.com PRELIMINARY
NOT APPROVED FOR
BID/ CONSTRUCTION
NOT FOR CONSTRUCTION
Know what's below
Call before you dig
dial 811
SITE LOCATION MAP
NOT TO SCALE
SITE
FORT MILL SOUTHER BYPASS
WHITES ROAD
DOBYS BRIDGE RD
N DOBYS BRIDGE RD
HOLBROOK ROAD
33
32
35
34
36
37
38
39
43CONCRETE FLUME
52TYPICAL LOCATION FOR FOUR OUTDOOR TABLES. WHEN MORE
SPACE IS AVAILABLE, OUTDOOR SEATING MAY BE EXPANDED.
5
6
1
3
2
4
SITE PLAN DESIGN NOTES & KEY PLAN
44
46
45A
51
"TWO ORDER LANES" SIGN (SEE SIGNAGE PACKAGE)
"LANES MERGE" SIGN (SEE SIGNAGE PACKAGE)
5A
5B
6A
6B
6C
6D
6E
6F
6G
6H
6I
6J
6K
7
CURB RAMP WITH FLARED SIDES8
CURB RAMP WITH SHORT FLARED SIDES8A
RETURNED CURB ACCESSIBLE RAMP9
10
11
12
DRIVE-THRU PLAN13
DRIVE-THRU ISOMETRIC14
CONCRETE WHEEL STOP15
LANDSCAPE & IRRIGATION PROTECTOR16
SPILLING 24" CONCRETE CURB & GUTTER17A
CATCHING 24" CONCRETE CURB & GUTTER
CURB HEIGHT TO MATCH CONC. PAVEMENT AT DRIVE-THRU DOOR17C
17D
ROLLOVER/MOUNTABLE CURB18
SCREENED REFUSE ENCLOSURE (SEE ARCH PLAN SHEET A-103)19
SCREENED REFUSE ENCLOSURE STAGGERED19A
SCREENED REFUSE ENCLOSURE ALTERNATE DRAINAGE19B
CONCRETE BOLLARD20
TYPICAL PAVEMENT SECTION - MEDIUM DUTY
TYPICAL PAVEMENT SECTION - HEAVY DUTY
21A
21B
TRANSVERSE & LONGITUDINAL CONTRACTION JOINT22
TRANSVERSE & LONGITUDINAL DOWELED CONSTRUCTION JOINT23
24
CONCRETE PAVING25
ALUMINUM HANDRAIL26
TYPICAL ADA RAMP AND HANDRAIL27
CONTRACTION JOINT28
KEYED CONSTRUCTION JOINT29
LONGITUDINAL BUTT JOINT30
EXPANSION JOINT31
RETAINING WALL WITH HANDRAIL ON TOP
(HANDRAIL SIMILAR TO DETAIL 26/C-4.2)
48
40
41
42
49
EX. ASPHALT / PROP. CONCRETE INTERFACE
TRANSFORMER
CHICK-FIL-A PRIME SIGN (SEE SIGNAGE PACKAGE)
SHORT TERM BIKE PARKING
EX./PROP. CONCRETE INTERFACE
EX./PROP. CURB INTERFACE
THICKENED SLAB EDGE AT RAILING CORE-DRILLS
PAVEMENT STRIPING AREA
CLEARANCE BARS (SEE SIGNAGE PACKAGE)
LANDSCAPED AREA (SEE LANDSCAPE PLAN)
ROOF DOWNSPOUT (TO CONNECT TO SITE DRAINAGE SYSTEM)
GREASE TRAP (SEE UTILITY PLAN)
5'x5' LANDING AND ENTRY DOOR FROST SLAB
MENU BOARD LOOP DETECTION SYSTEM
MENU BOARD & CANOPY ORDERING STATION
PAINTED CROSS WALK
MULTI-LANE DIRECTIONAL GRAPHICS
50FLAGPOLE, 30' (SEE SIGNAGE PACKAGE)
LIGHT DUTY PAVEMENT RESURFACE21C
534" THICK CONCRETE STRIP BETWEEN BUILDING
AND BACK OF CURB
546" THICK CONCRETE SIDEWALK BETWEEN
DRIVE-THRU LANE AND BUILDING
554" WIDE PAINT STRIPE
17B
56STANDARD LIGHT POLE
45 EX./PROP. ASPHALT INTERFACE
57CURBSIDE DELIVERY SIGN (SEE SIGNAGE PACKAGE)
58CONCRETE STRIPING AREA. CONCRETE TO BE PER
CONCRETE PAVING DETAIL
59CONCRETE VALLEY GUTTER
60A2' WIDE CONCRETE FLUME
CONCRETE APRON @ TRASH ENCLOSURE
61CATERING & CARRY-OUT (SEE SIGNAGE PACKAGE)
62CURBSIDE DELIVERY (SEE SIGNAGE PACKAGE)
632' WIDE 4" THICK CONCRETE LANDSCAPE PROTECTION STRIP
28" CONCRETE CURB & GUTTER17
11A
BICYCLE PARKING5C
60B3' WIDE CONCRETE FLUME
LONG TERM BIKE PARKING
47A
47B
ZEROVA AX 48 EV PARKING5D
64WALL SIGN - ICON 6.0' (SEE SIGNAGE PACKAGE)
65WALL SIGN - SCRIPT 5.0' (SEE SIGNAGE PACKAGE)
66WELCOME STAMP (SEE SIGNAGE PACKAGE)
TRANSITION CURB HEIGHT W/ RAMPED CONC. PAVEMENT
TO MATCH LEVEL PAVEMENT AT DRIVE-THRU DOOR
PAINTED DIRECTIONAL ARROW
PAINTED DRIVE-THRU GRAPHICS
PAINTED STOP LINE GRAPHIC
PAINTED HANDICAP PARKING SYMBOL
ACCESSIBLE PARKING STALL
60° PARKING STALL @ 9' x 18' MIN.
90° PARKING STALL @ 9' x 18' MIN.
DIRECTIONAL SIGNAGE (SEE SIGNAGE PACKAGE)
"STOP" SIGN (SEE SIGNAGE PACKAGE)
"ACCESSIBLE PARKING" SIGN (SEE SIGNAGE PACKAGE)
"CIRCLE BUILDING FOR DRIVE-THRU SERVICE"
(SEE SIGNAGE PACKAGE)
"RIGHT TURN ONLY" SIGN (SEE SIGNAGE PACKAGE)
"ONE WAY" SIGN (USE APPLICABLE DIRECTION)
(SEE SIGNAGE PACKAGE)
"LEFT TURN ONLY" SIGN (SEE SIGNAGE PACKAGE)
"PEDESTRIAN CROSSWALK" SIGN (SEE SIGNAGE PACKAGE)
"DO NOT ENTER" SIGN (SEE SIGNAGE PACKAGE)
"NO PARKING" SIGN (SEE SIGNAGE PACKAGE)
SIDEWALK ACCESSIBLE RAMP
TRUNCATED DOMES - CAST IN PLACE (ONLY IF REQUIRED)
TYPICAL CONCRETE SIDEWALK (SEE DETAIL FOR REVISIONS)
TYPICAL CONCRETE SIDEWALK SECTION WITH ADDED BLACK TENT MIX
FOR AREAS WITH A CROSS SLOPE TO STEEP FOR PEDESTRIAN ACCESS
SIDEWALK WITH CURB & GUTTER SECTION (SEE DETAIL FOR REVISIONS)
18
7
98
DO NOT ENTER
DRIVETHRU
DRIVETHRU
ONE-WAY
ONE-WAY
UGE UGE UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGT UGT
UGT
UGT
UGT
UGT
UGT
UGT
UGT
UGT
UGT
UGT
UGT
UGT
UGT
UGT
UGT
UGT
UGT
UGT
UGT
UGT
UGT
UGT
UGT
UGT
UGT
UGT
UGT
UGT
UGT
UGT
UGT
UGT
6''SS
6''SS
6''SS
6''SS
6''SS
6''SS
6''SS
6''SS
6''SS
6''SS
6''SS
6''SS6''SS
6''SS
6''SS
6''SS
6''SS
6''SS
6''SS
6''SS
6''SS
6''SS
6''SS
6''SS
6''SS 6''SS6''SS6''SS6''SS6''SS6''SS6''SS
35FT BUILDING SETBACK
ONE-WAY
ONE-WAY
ONLY
P14-SE-BASE - 5,183 SF90 SEATS (INTERIOR)16 SEATS (EXTERIOR
74 PARKS FFE = 657.50
7
5
73
96
8
GAS GAS GAS GAS GAS
UGT UGT UGT UGT UGT UGTUGT UGT UGT UGT UGT UGT UGT UGT UGT UGT UGT UGTUGT UGT UGT UGT UGT UGT UGT UGTUGT UGT UGT UGT UGTUGT UGT UGT UGT UGT UGT UGT UGT UGT UGT UGT UGTUGT UGT UGT
UGT
UGTUGT UGT UGT
UGT
UGT
UGT
FH
TT
W W
W
W
W WSS
SS
SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS
SS
SS
SS
SS
GAS GAS GAS GAS GAS
GAS GAS GAS GAS
GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS
EX. 6"PVC
EX. 15"RCP
EX. 18"RCP
EX. 18"CPP
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
WWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWW
FORT MILL PARKWAY
(VARIABLE R/W) PUBLIC R/W
(PB. E362, PG. 8 & 9)
(PB. E336, PG. 8)
UGT
UGT
UGT
UGT
EX. STONE BASE
EX. GRAVEL
OHP
OHP
OHP
OHP
OHP
OHP
OHP
N 05°14'42" W
228.71'
S 87°22'55" E
246.27' N 83°25'50" E
83.05'
S 03°19'47" E
39.66'
S 14°09'11" E
113.40'
C1
C2
L1
EX. OVERHEAD SIGNAL
APPROXIMATE LOCATIONOF EXISTING WATERLINE
C3
5' SETBACK
35' SETBACK
10' SETBACK
EX. 15"RCP
EX. 8"PVC
EX. STONE BASE
EX. 15"RCP
EX. 8"PVC
EX. 6"PVC
(A)
(PRIVATE DRIVE)
(PRIVATE DRIVE)
POB
5
2''W
2''W
2''W
2''W
2''W
2''W
2''W
2''W
2''W
2''W
2''W
2''W
2''W
2''W
2''W
2''W2''W
2''W
4''W
4''W
4''W
4''W
4''W
4''W
4''W
4''W
4''W
4''W
4''W
4''W
4''W
4''W
4''W
4''W
4''W
GAS
GAS
GAS
GAS
GAS
GAS
GAS
GAS
GAS
GAS
GAS
GAS
GAS
GAS
GAS
GAS
GAS
GAS
GAS
GAS
GAS
GAS
GAS
GAS
GAS
GAS
GAS
GAS
GAS
3/4''W3/4''W
3/4''W
3/4''W
3/4''W
3/4''W
3/4''W
3/4''W
3/4''W
3/4''W
3/4''W
3/4''W
3/4''W
3/4''W3/4''W3/4''W3/4''W3/4''W3/4''W3/4''W3/4''W3/4''W3/4''W3/4''W3/4''W3/4''W3/4''W3/4''W3/4''W3/4''W3/4''W3/4''W3/4''W3/4''W3/4''W
3/4''W
3/4''W
3/4''W
3/4''W
3/4''W
3/4''W
3/4''W
3/4''W
3/4''W
3/4''W
3/4''W
3/4''W
3/4''W
3/4''W
3/4''W
3/4''W
3/4''W
3/4''W
3/4''W
3/4''W
3/4''W
3/4''W
3/4''W
3/4''W
3/4''W
3/4''W
3/4''W
3/4''W
4''SS
4''SS
4''SS
4''SS
DO NOT ENTER
DO NOT ENTER
DO NOT ENTER
2''W
2''W
2''W
2''W
2''W 2''W2''W
UGEUGEUGE
EX. MHSS
TOP=653.67'
IE=642.77'(IN)
IE=642.56'(OUT)
EX. CB EX-5
FL=653.73'
IE=646.54'(IN)
IE=646.47'(OUT)
EX. MHSS
TOP=656.23'
IE=644.10'(6")
IE=644.04'(IN)
IE=643.86'(OU
T)
EX. CB EX-2
FL=654.40'
IE=646.31'(A)
IE=646.18'(IN)
IE=646.00'(OUT)
EX. IE=654.59'
EX. CB EX-6
FL=655.03'
IE=647.02'
EX. MHSS
TOP=651.62'
IE=645.64'(IN)
IE=645.40'(OUT)
EX. GUARD RAIL
EX. FH
20' WATER EASEMENT
EX. CB EX-3
FL=655.61'
IE=647.50'
20' WATER EASEMENT
3-Wildfire Tupelo
3-Wildfire Tupelo
84-Needlepoint Holly
16-Needlepoint Holly
40-Needlepoint Holly
5-Needlepoint Holly
3-Southern Magnolia3-Willow Oak
3-Willow Oak
3-White Fringe Tree 3-White Fringe Tree
5-Willow Oak
23-Needlepoint Holly
6-Chinese Elm
6-Natchez Crepe Myrtle
3-White Fringe Tree
13-Rose Creek Abelia
15-Rose Creek Abelia
35-Asiatic Jasmine
36-Asiatic Jasmine
45-Big Blue Liriope
40-Big Blue Liriope
11-Pink Muhly Grass
Sod
Sod
Sod Sod
Sod
Sod
Sod
Sod
Sod
Sod
Sod Sod
Sod
Sod
Sod
Sod
Sod
Sod
Sod
Sod
Sod
Sod
35-Asiatic Jasmine
12-Blue Point Juniper
PERMIT
PERMIT
Information contained on this drawing and in all digital files
produced for above named project may not be reproduced in
any manner without express written or verbal consent from
authorized project representatives.
MLD PROJECT #
PRINTED FOR
DATE
SHEET
SHEET NUMBER
DRAWN BY
Chick-fil-A
5200 Buffington Road
Atlanta, Georgia 30349-2998
REVISION SCHEDULE
FSU#
CHICK-FIL-A
2026033
2/23/26
MB
DOBY'S BRIDGE FSU
FORT MILL PARKWAY
FORT MILL, SC 29715
05201
NO. DATE DESCRIPTION
Landscape Plan
L-101
BY
LANDSCAPE REQUIREMENTS
A. STREET TREES
REQUIRED 1. Fort Mill Parkway: 430 LF / 50 = 9 street trees
North: 342 LF (less 66 feet) / 50 = 7 street trees
East: 212 LF / 50 = 5 street trees
PROVIDED 1. Fort Mill Parkway: (3) Southern Magnolia, (6) Willow Oak = 9 street trees
North: (7) Willow Oak = 7 street trees
East: (5) Willow Oak = 5 street trees
B. PLANTING AREA
REQUIRED 1. Fort Mill Parkway: 35' setback x 430 LF = 15,050
15,050 / 2,500 = 6.02 x 2 = 12 trees
50% x 12 = 6 canopy trees
2. Fort Mill Parkway: 35' setback x 430 LF = 15,050
15,050 / 2,500 = 6.02 x 10 = 60 shrubs
50% x 60 = 30 evergreen shrubs
PROVIDED 1. (6) Black Gum, (6) Chinese Fringe Tree = 12 trees
(6) Black Gum = 6 canopy trees
2. (84) Needlepoint Holly = 84 shrubs
(84) Needlepoint Holly = 84 shrubs
PLANT SCHEDULE
Symbol Qty Botanical Name Common Name Scheduled Size Remarks
Trees
9 Chionanthus virginicus White Fringe Tree 2" Cal.; 10' Hgt.
6 Lagerstroemia indica 'Natchez' Natchez Crepe Myrtle 8-10' Hgt x 5-6' Spr Multi-trunked
3 Magnolia grandiflora Southern Magnolia 3" Cal.; 10' Hgt Full to ground
6 Nyssa sylvatica 'Wildfire' Wildfire Tupelo 3" Cal.; 12' Hgt. B & B; single straight leader
11 Quercus phellos Willow Oak 3" Cal.; 12' Hgt B & B; single straight leader
6 Ulmus parvifolia 'Chinese' Chinese Elm 3" Cal.; 12' Hgt
Shrubs
28 Abelia x chinensis 'Rose Creek' Rose Creek Abelia 3 Gal
168 Ilex cornuta 'Needlepoint' Needlepoint Holly 24" Hgt.
12 Juniperus chinensis, 'Blue Point' Blue Point Juniper 6 Hgt.
11 Muhlenbergia capillaris Pink Muhly Grass 3 Gal.
Groundcovers
85 Liriope muscari 'Big Blue' Big Blue Liriope 1 Gal Plant 18" OC
106 Trachelospermum asiaticum Asiatic Jasmine 1 Gal.
Other
0 20 40 FT
ATLANTIC LANDSCAPE NOTES
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.
24.
25.
26.
Landscape Contractor to read and understand the Landscape Specifications prior to finalizing bids. The Landscape
Specifications shall be adhered to throughout the construction process.
Contractor is responsible for locating and protecting all underground utilities prior to digging.
Contractor is responsible for protecting existing trees from damage during construction.
All tree protection devices to be installed prior to the start of land disturbance, and maintained until final landscaping.
All tree protection areas to be protected from sedimentation.
All tree protection fencing to be inspected daily, and repaired or replaced as needed.
No parking, storage or other construction activities are to occur within tree protection areas.
All planting areas shall be cleaned of construction debris (ie. concrete, rock, rubble, building materials, etc) prior to adding
and spreading of the topsoil.
General Contractor is responsible for adding a min of 4” clean friable topsoil in all planting beds and all grassed areas.
Graded areas to be held down the appropriate elevation to account for topsoil depth. See Landscape Specifications for
required topsoil characteristics.
Remove debris, gravel, rock, and media not suitable for planting from all parking lot islands. Fracture/loosen subgrade to a
min. 24” depth and ensure proper drainage is achieved; complete water perk test. Add planting mix to achieve desired soil
elevation; refer to landscape specifications and landscape island detail.
Prior to beginning work, the Landscape Contractor shall inspect the subgrade, general site conditions, verify elevations,
utility locations, irrigation, approve topsoil provided by the General Contractor and observe the site conditions under which
the work is to be done. Notify the General Contractor of any unsatisfactory conditions, work shall not proceed until such
conditions have been corrected and are acceptable to the Landscape Contractor.
Any deviations from the approved set of plans are to be approved by the Landscape Architect.
Landscaping shall be installed in conformance with ANSI Z60.1 the “American Standard for Nursery Stock” and the
accepted standards of the American Association of Nurserymen.
Existing grass in proposed planting areas shall be killed and removed. Hand rake to remove all rocks and debris larger
than 1 inch in diameter, prior to adding topsoil and planting shrubs.
Soil to be tested to determine fertilizer and lime requirements prior to laying sod.
Annual and perennial beds: add min. 4 inch layer of organic material and till to a min. depth of 12 inches. Mulch annual and
perennial beds with 2-3 inch depth of mini nuggets.
All shrubs beds (existing and new) to be mulched with a min. 3 inch layer of mulch (mulch type to be: double shredded
hardwood mulch).
Planting holes to be dug a minimum of twice the width of the root ball, for both shrub and tree. Set plant material 2-3”
above finish grade. Backfill planting pit with topsoil and native excavated soil.
Sod to be delivered fresh (Cut less than 24 hours prior to arriving on site), laid immediately, rolled, and watered thoroughly
immediately after planting. Edge of sod at planting beds are to be "V" trenched, or metal edging shall be installed if rock
mulch is used; see Landscape Details.
Any existing grass disturbed during construction to be fully removed, regraded and replaced. All tire marks and indentions
to be repaired.
Water thoroughly twice in first 24 hours and apply mulch immediately.
The Landscape Contractor shall guarantee all plants installed for one full year from date of acceptance by the owner. All
plants shall be alive and at a vigorous rate of growth at the end of the guarantee period. The Landscape Contractor shall
not be responsible for acts of God or vandalism. See Landscape Specifications for Warranty requirements/expectations.
Any plant that is determined dead, in an unhealthy, unsightly condition, lost its shape due to dead branches, or other
symptoms of poor, non-vigorous growth, shall be replaced by the Landscape Contractor. See Landscape Specifications for
warranty requirements/expectations.
Site to be 100% irrigated in all planting beds and grass area by an automatic underground Irrigation System. Irrigation
as-built shall be provided to the owners rep within 24 hours of irrigation install completion.
Stake all evergreen and deciduous trees as shown in the planting detail and as per the Landscape Specifications.
Remove stakes and guying from all trees after one year from planting.
19