RecordWell Data

Planning Commission Regular Meeting Agenda (PDF)

Town of Fort Mill · York County · meeting of Mar 17, 2026 · Agendas

Open the original document More from Town of Fort Mill

Text

Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.

TOWN OF FORT MILL PLANNING COMMISSION MEETING March 17, 2026 205 North White Street 6:00 PM CALL TO ORDER APPROVAL OF MINUTES 1. Regular Meeting: February 17, 2026 [Pages 2-6 ] NEW BUSINESS 1. Commercial Appearance Review: Chick-fil-A [Pages 7-19] Request fr om Mark Campbell to grant Commercial Appearance Review approval for the construction of a new restaurant with a drive-through located at 2325 Azimuth Trail. ADJOURN The follo wing press was notified of the meeting by email or fax in accordance with the Freedom of Information Act: The Herald, CN2, WRHI, WSOC, and WBTV. The agenda was also posted at the entrance to Town Hall the required length of time and on the Town website. The Town of Fort Mill is committed to assuring accessibility with reasonable accommodation, of Town services and facilities for all individuals, in compliance with federal law. Please contact the Town Manager’s Office at 803-547-2116 if you need assistance. 1 TOWN OF FORT MILL PLANNING COMMISSION MEETING February 17, 2026 205 N. White St. 6:00 PM Present: Chairman Mark Kerr, Vice Chairman Matt Lucarelli, Dan Stout, Sarah Curtis, Director Penelope Karagounis, Deputy Planning Director Joey Adams - Raczkowski, Planner Emily Hawkins, Planner Carter Bliss Absent: Jonathan Hutchinson, Erin Pratt, Daniel Reynolds Guest: See attached sign-in sheet C hairman Mark Kerr called the Planning Commission meeting to order at 6:00 p.m. on Tuesday, February 17, 2026. C hairman Mark Kerr asked for a motion to approve Planning Commission meeting minutes from January 20, 2026, to be made. Vice Chairman Matt Lucarelli made the motion. Chairman Mark Kerr seconded the motion. The motion to approve the minutes from January 20, 2025, was approved by a vote of 4-0. O LD BUSINESS 1. Commercial Appearance Review: Unique USA Deputy Planning Director Joey Adams-Raczkowski gave a brief report of the request from Patrick Tormeno, to grant Commercial Appearance Review Approval for of The Loom, a 4- story multifamily building with ground floor retail. The application was deferred from the January 20, 2026, Planning Commission meeting, and the applicant had brought additional resources to show changes made based on the Commission’s input. The previous motion had been to defer based on wanting to see architectural façade changes, including parking deck elevations and landscaping. Deputy Director Adams-Raczkowski noted that staff had reviewed all the materials and was again going to defer to the applicant to present their project, given the scope of the development. Justin Maxwell, working for BB&M, presented the architectural changes to the Commission. These changes included added brick, and higher quality materials to enhance the primary frontages. Additionally, Maxwell introduced parking deck elevations, as well as 3D materials to assist in visualizing changes. The applicant presented the required landscaping buffer, as well as the landscaping around the parking deck entrance on Williamson. One of the changes presented is the use of board-formed architectural concrete, with the possibility of using the original Mills’ wooden plank floors as the forms, with the end result 2 looking like wood-textured concrete. Another was the use of vinyl-coated chain link fence in the pen areas of the parking deck. Vice Chairman Matt Lucarelli questioned the longevity of use of the salvaged wood, citing experience using board-forms, and their ability or lack thereof to sustain repeated use. Additionally, the Vice Chairman noted that he was satisfied with the addition of brick elements to the right side of the south elevation, and that the additional cost will allow the development to become a prominent feature in our town. Vice Chairman Matt Lucarelli also sked about the options regarding the black vinyl-coated chain link fence, and if there was a better-looking option that still met the code perspectives of an open deck. Justin Maxwell highlighted the placement of the fence on less-exposed areas of the parking deck, and that they would make sure to present additional designs of chain-link fence for the portions that would be visible from the street or sidewalk. Vice Chairman Matt Lucarelli also discussed the importance of plantings and trees around the parking deck to maximize greenery around the parking deck, providing the nearby residents with a good visual screen. Planning Director Penelope Karagounis noted that the board had the option to increase the amount of landscaping if they choose. Additionally, Director Karagounis noted that if the Board wanted to have something explicitly stated, that they would need to do so in form of a motion. Deputy Director Joey Adams-Raczkowski noted that he had reviewed the current landscaping plan based on the MXU rezoning and approval the applicants went through, as directed by the Assistant Town Manager, and felt that the landscaping had met the intent of the MXU rezoning. Chairman Mark Kerr noted the importance of greenery to not only create a more natural environment, but also to block out the floodlights of the parking deck. Chairman Kerr asked about the bleed distance and brightness of the required foot candle on and around the parking deck. The applicants, Justin Maxwell and Patrick Tormeno, spoke about the height elevation and the possibility of installing baffles or shields that will project the required light onto the parking deck, while blocking the light from the residential neighbors across the street. Commissioner Sarah Curtis asked about the number of canopy trees that would be installed along that side of the parking deck, noting the dual purpose of both shade and light blockage that the trees would have. Jerry Gronske, owner of the development, noted the balance required to both create a safe environment for users of the parking deck and mitigate light bleeding onto the residential neighbors. Patrick Tormeno noted the significance of the height difference between the proposed parking deck and the neighboring lots across Williamson Street. Mr. Tormeno also noted that they will be planning on saving a 45-inch oak tree on the other side of Watson Street. Commissioner Dan Stout asked about the width of the main entrance on Watson Street, and if it was wide enough for large trucks. Patrick Tormeno noted that the road meets the width requirement for Fire safety and is 26 feet wide. Commissioner Stout also asked about the 3 type of gates on the parking deck entrances. Mr. Tormeno described the high-speed, credential-access roller gates that would be used on both entrances. The board and the applicants discussed the ability to bring samples of the board-formed concrete and the chain-link fence to the next meeting, or to the Planning staff to review and discuss with the board members on a separate date. They also discussed the possibility of deferring only a section of the design elements, and approving specific materials that the Board agrees on. Chairman Kerr entertained a motion. Commissioner Sarah Curtis made a motion to recommend approval of the package with a few conditions: review of the parking deck chain-link fencing, review of the lighting and photometric plan, and the options to shield lighting across the street, while also providing enough light to meet code in the parking deck. Commissioner Dan Stout seconded the motion. By vote of 4-0, the motion to recommend approval of the presented landscaping package, on the conditions that the parking deck fencing and lighting plan and fixtures are provided to the Planning Commission for approval. NEW BUSINESS 1. Commercial Appearance Review: Harris Teeter Planner Emily Hawkins gave a brief overview of the request Rajeev Bhave, representing Harris Teeter, to grant Commercial Appearance Review approval for the construction of a new Harris Teeter Grocery and Pharmacy on 2068 Mary Hinson Court. Ms. Hawkins noted that the applicant had spoken with the Commission in both November of 2019 and August 2025, and that Mr. Bhave was here to submit a few exterior changes to the front of the building. Ms. Hawkins noted that the staff recommends a motion of approval, with the ability for staff to make minor modifications upon submittal. The board discussed the location of the proposed changes, with the main change being change of Pharmacy lanes from two to one, and the removal of a canopy on the left side of the façade, above the home shopping entrance (for employees only). Rajeev Bhave explained that the plan was originally approved in 2019 without a canopy, and then in 2025 they revisited the process under the impression that the demand for home shopping and curbside delivery would be enough to justify a full canopy, but the demand has subsided, and the canopy has been removed, to revert to the previous 2019 plan. Chairman Kerr entertained a motion. Vice Chairman Matt Lucarelli made a motion to recommend Commercial Appearance Review approval upon allowing staff to administratively approve minor adjustments to the proposed plan to satisfy the comments and requirements made by staff. Commissioner Sarah Curtis seconded that motion. By vote of 4-0, the motion to recommend CAR approval upon allowing staff to administratively approve minor adjustments to the proposed plan, was approved. 4 Chairman Kerr entertained a motion to adjourn. Commissioner Sarah Curtis made a motion to adjourn. Commissioner Stout seconded that motion. By a vote of 4-0, the motion of adjournment was approved. T he meeting adjourned at 6:47 p.m. R espectfully submitted, Carter Bliss, Planner February 23, 2026 5 6 Meeting Information Meeting Type Planning Commission Meeting Date March 17, 2026 Request Summary Request Type Action (Old Bus.) X Action (New Bus.) Info/Discussion Public Hearing Executive Session Other Case Summary Case Type Annexation Rezoning Text Amendment Subdivision Plat X Appearance Review Other Property Information Applicant Mark Campbell Property Owner ARIC Fort Mill, LLC Property Location 2325 Azimuth Trail Tax Map Numbers 020-12-01-352 Current Zoning HC, Highway Commercial / COD-N, Corridor Overlay District-Node Existing Use Vacant Title Request from Mark Campbell to grant Commercial Appearance Review approval for the construction of a new restaurant with a drive-through located at 2325 Azimuth Trail. Background Information Site Characteristics The property is located at the corner of Fort Mill Parkway and North Dobys Bridge Road and is part of the overall Catawba Ridge Market development. Neighboring Uses Direction Zoning Existing Use North R-15 Nims Village Subdivision South HC / COD-N Fort Mill Parkway East HC / COD-N Vacant West HC / COD-N Vacant Zoning Summary The site is currently zoned HC, Highway Commercial and is in the COD -N, Corridor Overlay District-Node. 7 Dimensional Requirements: - Maximum building height: 45’ - Minimum front yard setback: 35’ - Minimum side yard setback: 10’ - Minimum rear yard setback: 35’ Parking Requirements (for uses given): - Total spaces provided: 74 spaces (4 ADA) - The rear façade of buildings shall not be visible from the corridor and shall be oriented away from view from the corridor or shall be screened by landscaped buffers. - All off-street parking, loading, and service areas shall be screened from view of the corridor. Architectural features: Article II, Section 24(5)(C) of the Zoning Ordinance provides the following architectural guidelines for the COD-N: 1) Materials: a. Buildings shall be designed to use building materials such as rock, stone, brick, stucco, concrete, wood, or Hardiplank. b. No mirrored glass shall be permitted on any facades in COD -N and mirrored glass with a reflectance no greater than 20 percent shall be permitted in COD. c. Corrugated metal shall not be used in any façade. 2) In COD-N, variations in the rooflines and facades of adjacent buildings shall be encouraged to avoid monotony. 3) In COD-N, any nonresidential façade facing the corridor or any other street shall be articulated with architectural features and treatments, such as windows, awnings, scoring, trim, and changes in materials (i.e., stone “water table” base with stucco above), to enhance the quality of pedestrian environment of the public street, particularly in the absence of a primary entrance, so that the façade is of the same quality and standard of design as if it were the front/primary façade. Landscape Standards: - Street trees shall consist of canopy trees planted within the streetscape zone (the first 15 feet of the setback closest to the corridor) at rate of one tree per 50 linear feet along all corridor frontages. Tree spacing shall be not more than 60 feet and not less than 40 feet on center. At planting, street trees shall be a minimum of two inches in caliper (measured four feet above ground level) or eight feet in height. - All new development or expansions of existing development resulting in a minimum ten percent increase in building area or lot area shall provide landscaping within the setback in accordance with this subsection. For purposes of this subsection, the plantin g 8 area shall be determined by multiplying the lot frontage, less driveways, times the minimum required setback width to determine required planting area. Trees: For every 2,500 square feet of planting area, a minimum of two trees shall be planted . At least 50 percent of the trees planted to meet this requirement shall be canopy trees. At planting, required trees shall be a minimum of two inches in caliper (measured four feet above ground level), and shall have a mature height of at least 35 feet. Street trees planted in this area shall be counted toward the minimum tree planting requirements. Significant trees protected in accordance with section 3 of the landscaping standards of article IV may be counted to satisfy this tree planting requirement. Shrubs: For every 2,500 square feet of planting area, a minimum of ten shrubs shall be planted. At least 50 percent of the shrubs planted shall be evergreen. - Parking areas shall be planted with trees a minimum of two inches in caliper measured six inches above ground level, so that there is at least one tree per ten parking spaces within the parking lot. Such trees shall be adequately staked and protected by curbing against damage by vehicles. A minimum planting area, equivalent to 18 square feet per tree shall be provided. - Screening of refuse collection facilities shall provide secure, safe, and sanitary facilities for the storage and pickup of refuse. Such facilities shall be convenient to collection and shall be appropriate to the type 14 and size of use being served. All refuse storage facilities shall be screened on three sides by a solid wooden fence or masonry wall and a tight evergreen hedge. The fourth side shall be angled to minimize the view of the refuse collection facility or shall be screened by an opaque gate made of durable materials. The screening shall be of sufficient height and design to effectively screen the facility from the view of nearby residential uses, streets, adjacent properties, and recreational facilities. Applicant Proposal The applicant is seeking Commercial Appearance Review approval for a new 5,138 sq ft restaurant with a drive -through. Materials are comprised of brick masonry , prefinished metal coping, and paint. A dumpster enclosure is also proposed comprised of a single brick claddi ng and prefinished metal coping to match the proposed building. Staff Recommendation The building plans are currently pending review by Town staff and generally compl y with all zoning requirements. Staff requests that Planning Commission evaluate the need for a sidewalk system across the entirety of the property and the addition of bike racks to promote pedestrian activity. Should the Planning Commission wish to grant commercial appearance review approval, staff would request including language in the approval motion to allow for minor modifications to be 9 made to the plans by staff to include bike racks , a more robust sidewalk system, and accommodate comments or concerns from reviewing departments. Alternatives 1. Grant commercial appearance review approval. 2. Grant commercial appearance review approval with conditions. 3. Deny commercial appearance review approval. Staff Recommendation Recommendation Staff recommends in favor of APPROVAL for the request, conditioned upon allowing staff to administratively approve minor adjustments to the proposed plan to satisfy the comments and requirements made by staff. Name & Title Emily Hawkins, Planner Department Planning Department Date of Request 2/23/2026 Legislative History Planning Commission 3/17/2026: Scheduled Attachments • Aerial Map • Zoning Map • Commercial Appearance Review Application • Proposed Elevations • Proposed Dumpster Enclosure Elevations • Site Plan • Landscape Plan 10 Aerial Map Zoning Map 11 Date Received: Planning Commission Date: Fort MiLL SOUTH CAROLINA Planning Department 205 White Street Fort Mill, SC 29715 Phone: 803-835-2337 Commercial Appearance Review Application General Information Mark Campbell Applicant Name: Applicant Address: 101° Commerce Pr, Bogart, GA 30622 Email:mark@carterengineerin9'com Phone: 770-725-1200 Property Owner Name: ARIC FORT MILL LLC Property Owner Address: 2825 S Blvd Ste 300, Charlotte, NC 28209 Email: besmith@astonprop.com phone: 70^~3'I9~4921 Property Information 2325 AZIMUTH TR Property Address: Submission Checklist Completed application 0Full set of elevations with dimensions Site plan Landscape plan Building material samples *there is no fee associated with this application .Tax Map ID # : 0201201352 Proposed Use: RESTAURANT WITH DRIVE THRU zoning Designation: HC - HIGHWAY COMMERCIAL Please provide a brief narrative of the proposed scope of work: PROPOSED RESTAURANT WITH APPROXIMATELY 5,200 SF BUILDING SIZE AND 90 SEATS INTERIOR AS WELL AS DRIVE THROUGH WITH ASSOCIATED PARKING AND UTILITIES. SITE IS ALSO KNOWN AS OUTLOT 2 OF THE CATAWBA RIDGE MARKET SUBDIVISION (HARRIS TEETER SHOPPING CENTER) SITE HAS FRONTAGE ALONG FORT MILL PARKWAY WITH ACCESS VIA AZIMUTH TRAIL INTERNAL .^ Applicant Signature:,J^^7 *Please submit all materials to Penelope Karagounis at pkaragounis@fortmillsc.gov at least three weeks prior to the meeting date* Updated2.13.2026 12 Article V of the Town of Fort Mill Zoning Ordinance outlines the following standards for Commercial Development Appearance Review: Sec. 1. - Purpose. Commercial development appearance review shall be required for all proposed commercial or office development in all zoning districts except the historic district. Compliance with the requirements for commercial development appearance review shall be required in addition to the requirements of the underlying zoning district. The purpose of commercial development appearance review is: 1) To promote Fort Mill's economic viability by encouraging commercial development that enhances the character of the town; 2) To enhance and protect property values by encouraging excellent design; 3) To encourage architectural freedom, imagination, and variety, and to encourage creative design solutions that will enhance the town's visual appearance. Sec. 2. - Definitions. As used in this section, words and terms shall have the following definitions: 1) Appearance review committee: The municipal committee responsible for ensuring that proposed commercial development complies with the appearance review standards for proposed commercial development. 2) Proposed commercial development: All new exterior construction or addition which adds square footage associated with commercial uses except for maintenance, minor repairs, restoration, and temporary structures. Commercial uses include all retail, business, and office uses. Sec. 3. - Site plan. A site plan prepared by a registered engineer or architect shall be submitted for all proposed commercial development. The site plan shall be drawn to scale and shall be accompanied by a narrative, as appropriate, showing and outlining the following: A) Name and address of applicant and site; B) Scale and north point; C) Total land area of site in square feet; D) Property boundaries; E) Location and dimensions of parking areas; F) Number of off-street and on-street parking spaces required by regulations and proposed; G) Location, use, elevations, and dimensions of proposed buildings and buildings within 50 feet of the site boundaries; H) Location and dimensions of proposed easements, conduits, and rights-of-way; I) Existing and proposed landscaping and plant materials, including the type, size, number, and spacing of plants; J) Type, height, and location of night lighting; K) Location and height of proposed signs; proposed setbacks of signs, elevation of each face of the proposed sign; size of letters and graphics; colors and frame materials and details; L) Loading areas and facilities; M) Pedestrian access; N) Location, height, and details of walls and fences; O) Curb cuts; P) Designation of the kind, color, and texture of all exterior materials. 2 13 Sec. 4. - Appearance review. 1) Commercial development appearance review by the appearance review committee shall be required for all zoning permits and special exceptions for proposed commercial developments to ensure conformity with the appearance standards. 2) Applications for commercial development appearance review shall be submitted on an application form obtained from the zoning administrator. No application shall go before the appearance review committee until the required site plan and an application fee have been submitted. The amount of the application fee shall be established by the town council during adoption of the annual budget ordinance. 3) Appearance review committee: A) The appearance review committee is created. B) Purpose: The appearance review committee shall be responsible for making recommendations on zoning and special exception permit applications for proposed commercial development. C) Membership: The appearance review committee shall consist of the members of the Fort Mill Planning Commission. D) Organization: 1) The chairman of the planning commission shall serve as the chairman of the appearance review committee. 2) The appearance review committee shall operate under the procedures and rules that govern the actions of the planning commission. architectural element of the building and site to which it relates.D)The colors, materials, and lighting of every sign shall be harmonious with the building and site to which it relates.E)The number of graphic elements on a sign shall be held to the minimum needed to convey the sign's principal message and shall be in proportion to the area of the sign.F)Each sign shall be compatible with signs on adjoining plots or buildings.G)Corporation logos shall conform to the criteria for all other signs.6)Miscellaneous structures: Miscellaneous structures and hardware shall be part of the architectural concept of the project. Materials, scale, and colors shall be compatible with the building and surrounding uses. 3 14 Sec. 5. - Appearance standards. 1) Relationship of building site: A) The proposed commercial development shall be designed and sited to accomplish a desirable view as observed from adjacent streets. B) Parking areas shall be enhanced with decorative elements, building wall extensions, plantings, berms, or other innovative means to screen parking areas from view from the streets. C) Utility services shall be underground. 2) Relationship to adjoining areas: A) Adjacent buildings of different architectural styles shall be made compatible by use of screens, sight breaks, materials, and other methods. B) Landscaping shall provide a transition to adjoining property. C) Texture, building lines, and mass shall be harmonious with adjoining property. Monotonous texture, lines, and mass shall be avoided. 3) Landscaping: Landscaping shall conform to article IV and other sections of this ordinance. 4) Building design: A) Architectural style is not restricted. Quality of design and compatibility with surrounding uses shall provide the basis of the evaluation of the appearance of a proposed commercial development. B) Materials shall be of good architectural character and shall be harmonious with adjoining buildings. C) Materials shall be suitable for the type and design of the building. Materials which are architecturally harmonious shall be used for all exterior building walls and other exterior building components. D) Materials and finishes shall be of durable quality. E) Building components, such as windows, doors, eaves, and parapets, shall have appropriate proportion and relationships to one another. F) Colors shall be harmonious and shall use compatible accents. G) Mechanical equipment or other utility hardware on roof, ground, or buildings shall be screened from view with materials harmonious with the building. H) Monotony of design shall be avoided. Variation in vegetation, detail, form, and siting shall be used to provide visual interest. 5) Signs: A) Signs shall conform to the provisions of article III and this article. B) Every sign shall be of appropriate scale and proportion in relation to the surrounding buildings. C) Every sign shall be designed as an integral 6) Miscellaneous structures: Miscellaneous structures and hardware shall be part of the architectural concept of the project. Materials, scale, and colors shall be compatible with the building and surrounding uses. 4 15 CANOPY NOTES: BUILDING MOUNTED CANOPIES - 8" THICK CANOPY - KYNAR FINISH OF STRUCTURE, FASCIA, & DECKING TO MATCH COLUMN MOUNTED CANOPIES - 10" THICK CANOPY - FINISH OF STRUCTURE TO BE - FINISH OF DECKING TO BE CP-1 CP-2 CP-1 GENERAL NOTES 1. ALL SIGNAGE PROVIDED BY OTHERS 2. REF FLOOR PLAN AND WINDOW LEGEND FOR STOREFRONT INFORMATION 3. DARPRO EXTRACTION PORT 40' MAX TO TRUCK ACCESS, RE: PLUMBING C4-B T/ HIGH PLATE 22' - 0" T/ LOW PLATE 21' - 6 1/2" T/ SOLDIER 13' - 0" B/ CANOPY 9' - 8" WATER TABLE 3' - 0" T/ SLAB 0' - 0" C/ SCONCE 8' - 0" 4'-8" 5'-9 1/8" 6'-0" 7'-7 1/2" 6'-0" 13'-0 1/2" 3'-4 1/2" 5'-2 5/8" 7 3/8" 4'-4" 6'-3" 6'-0" 1'-2" 6'-0" 1'-3 5/8" 2'-7" 2'-3 7/8" 1'-0 1/8" 4'-8" 47'-0 1/4" 25'-8" 2'-7" 3'-4" 29'-6" 83'-3 1/4" 32'-8" C4-LC3-C T/ HIGH PLATE 22' - 0" T/ LOW PLATE 21' - 6 1/2" T/ SOLDIER 13' - 0" B/ CANOPY 9' - 8" C/ SCONCE 8' - 0" WATER TABLE 3' - 0" T/ SLAB 0' - 0" 10'-2" EQ EQ 12'-8 3/4"2'-5 5/8"6'-0"4'-5 3/4"6'-4"4'-6 1/4"6'-0"2'-6 1/8"4 5/8"3'-4 1/2"8'-1 1/4"3'-4 1/2"2 1/8"3'-0 5/8"6'-0"3'-1 1/2"6'-0"1'-3 3/8"3'-4 1/4" 29'-6" 3'-4 1/4" 19'-5 1/2" 15'-5" 32'-3 3/4" 12'-8 3/4" 83'-3 1/4" 32'-8" T/ HIGH PLATE 22' - 0" T/ LOW PLATE 21' - 6 1/2" T/ SOLDIER 13' - 0" B/ CANOPY 9' - 8" C/ SCONCE 8' - 0" WATER TABLE 3' - 0" T/ SLAB 0' - 0" 6'-8 1/2" 6'-0" 4'-8" 6'-0" 4'-8" 6'-0" 10'-2" 3'-4 1/2" 1'-6 1/8" 5'-4 5/8" 6'-0" 6'-3 7/8" 5 1/8" 49'-1 1/8" 17'-8 1/2" 67'-3 1/4" T/ HIGH PLATE 22' - 0" T/ LOW PLATE 21' - 6 1/2" T/ SOLDIER 13' - 0" T/ SOLDIER +/- 11' - 3" B/ CANOPY 9' - 8" WATER TABLE 3' - 0" T/ SLAB 0' - 0" 6'-8" 3'-0" 2'-9 3/4" 32'-8 1/4" 23'-7 1/4" 3'-11" 60'-5" 6'-8" 3'-0" 35'-6" 23'-7 1/4" EXTERIOR FINISHES PREFINISHED METAL COPING COLOR: MIDNIGHT BRONZE BRICK VENEER COLOR: GLEN GERY - COURTLAND SIZE: MODULAR EXTERIOR PAINT COLOR: DARK BRONZE FINISH: SEMI-GLOSS STOREFRONT COLOR: DARK BRONZE BRICK VENEER COLOR: GLEN GERY - WHITEHALL SIZE: MODULAR BR-A BR-B EC-1 PT-113 ST-1 Chick-fil-A 5200 Buffington Road Atlanta, Georgia 30349-2998 Information contained on this drawing and in all digital files produced for above named project may not be reproduced in any manner without express written or verbal consent from authorized project representatives. CONSULTANT PROJECT # PRINTED FOR DATE SHEET SHEET NUMBER DRAWN BY REVISION SCHEDULE A 1 2 34 B C D E A B C D E 1234 CHICK-FIL-A BUILDING TYPE / SIZE: RELEASE: # 3/5/2026 10:21:35 AM Autodesk Docs://SC_05201_Dobys Bridge FSU_2026.1_FSR/05201_Dobys Bridge FSU_ARC.rvt A-302 COLOR ELEVATIONS DESIGN 02/19/2026 Author DOBYS BRIDGE FSU 05201 FORT MILL PKWY FORT MILL, SC 29715 10-SE-05201-A-302-COLOR ELEVATIONS CFSC05201 25.10 P14 SE BASE FSR FINISH SCHEDULE - EXTERIOR MAR K DESCRIPTION MANUFACTURER MODEL NAME MODE L NUMBER COLOR SIZE NOTE BR-A BRICK VENEER (PRIMARY) GLEN GERY COURTLAND * COURTLAND MODULAR BRICK SELECTIONS HAVE BEEN APPROVED BY CFA AND CITY REVIEW. NO SUBSTITUTIONS WITHOUT PRIOR APPROVAL. MORTAR TYPICAL ARGOS, SAN TAN BR-B BRICK VENEER (ACCENT) GLEN GERY WHITEHALL * WHITEHALL MODULAR BRICK SELECTIONS HAVE BEEN APPROVED BY CFA AND CITY REVIEW. NO SUBSTITUTIONS WITHOUT PRIOR APPROVAL. MORTAR TYPICAL ARGOS, SAN TAN CP-1 CANOPY METAL FASCIA DURA COAT DC19ST-2703 DARK BRONZE OIL RUBBED BRONZE METALLIC TEXTURE PVD CP-2 CANOPY METAL DECK WHITE SMOOTH WHITE, HIGH GLOSS EC-1 PARAPET WALL COPING DUROLAST / EXCEPTIONAL METALS MIDNIGHT BRONZE PT-100 EXTERIOR PAINT SHERWIN WILLIAMS SHER-CRYL HIGH PERFORMANCE ACRYLIC #B66-350 SW 2807 ROOKWOOD REFUSE ENCLOSURE. FINISH: SEMI-GLOSS ON DOOR FRAMES, SATIN ON WALLS PT-113 EXTERIOR PAINT SHERWIN WILLIAMS SHER-CRYL HIGH PERFORMANCE ACRYLIC #B66-350 SW BRONZETONE DARK BRONZE FINISH: SEMI-GLOSS EXTERIOR METALS ST-1 STOREFRONT YKK YES 45 DARK BRONZE (MATTE) E+H ARCHITECTS P.C. 750 OLD HICKORY BLVD. SUITE 150-2 BRENTWOOD, TN 37027 PHONE: 615.377.3111 EMAIL: CFATEAM@EANDHARCH.COM March 12, 2026 1/4" = 1'-0" EXTERIOR ELEVATION D4 1/4" = 1'-0" EXTERIOR ELEVATION C4 1/4" = 1'-0" EXTERIOR ELEVATION B4 1/4" = 1'-0" EXTERIOR ELEVATION A4 NO. DATE DESCRIPTION 03/12/2026 IFP 16 16 GA FORM DECK PANELS WELDED TO FRAME - PAINT GATE PULLS AS APPROVED BY OWNER. STEEL PLATE AND ANCHORAGE 1" DIAMETER STEEL DROP ROD 1-1/4" DIAMETER DRILLED HOLE IN CONCRETE DRIVE. STEEL BENT CLIP BOLTED TO STEEL MAIN FRAME - PAINT 6" LONG DROP ROD GUIDE VERTICAL EDGE OF CONCRETE SLAB BEHIND & BELOW GATE CONCRETE DRIVE - RE: CIVIL GRAY INDICATES PAINT PT-9 IN THIS DRAWING, TYP 1/2" EXPANSION JOINT - RE: CIVIL PT-113 PT-113 PT-113 9 3/4" 6" PIPE BOLLARD GATE POST BEYOND - PAINT 1/2" EXPANSION JOINT - RE: CIVIL CONCRETE PAVING - RE: CIVIL 6" MIN. CRUSHED STONE BASE POST FOUNDATION - RE: STRUCTURAL CONCRETE SLAB & FOOTING (RE: STRUCTURAL) SLOPE FOR DRAINAGE - RE: PLAN 1" CHAMFERED EDGE GATE PANEL STORAGE RM FLOOR 0'-6" PT-113 TOP OF GRADE 0'-0" GROUT CAVITY SOLID AT BELOW FLASHING LINE OF FINISHED GRADE - RE: CIVIL CONT. MEMBRANE FLASHING WITH WEEP HOLES AT 32" O.C. GROUT BOTTOM TWO COURSES SOLID, TYP AND EXTEND GROUTING DOWNWARD INTO FOOTING AS SHOWN ON STRUCTURAL DRAWINGSBRICK VENEER HORIZONTAL JOINT REINFORCEMENT WITH HOOK & EYE TYPE BRICK TIES - RE: STRUCTURAL EXTEND BRICK VENEER TO FOOTING BELOW. CONTRACTOR SHALL HAVE OPTION TO USE 4" THICK CMU INSTEAD OF BRICK AT AREAS BELOW FINISH GRADE. CONCRETE SLAB, RE: STRUCT. FOOTING - RE: STRUCTURAL LEVEL 1 0'-0" 1/2" EXPANSION JOINT AIR SPACE DAMPPROOFING 1'-0" H.M. DOOR PAINT PAINTED HOLLOW METAL DOOR & FRAME CONCRETE FILLED & REINFORCED CELL RE: STRUCTURAL SEALANT, TYP ALL SIDES 3 ANCHORS PER JAMB GROUT SOLID 8" CMU PT-100 SLOPE DECKING - RE: STRUCTURAL RAFTERS - RE: STRUCTURAL BOND BEAM - RE: STRUCTURAL 8" HARDIE PLANK 2X BLOCKING 2-PIECE METAL DRIP EDGE DARK BRONZE 10 D NAILS AT 6" O.C.ROOFING MEMBRANE JOIST ANCHORAGE - RE: STRUCTURAL HORIZONTAL JOINT REINFORCEMENT - RE: STRUCTURAL 7'-4" A.F.F. 2X TREATED TOP PLATE RE: STRUCTURAL FOR ANCHORAGE PT-31A PREFINISHED METAL COPING (DARK BRONZE) 2X8 TREATED TOP PLATE CONTINUOUS CLEAT RE: STRUCTURAL FOR ANCHORAGE BOND BEAM - RE: STRUCTURAL BRICK VENEER 1/2" CDX PLYWOOD CEILING - PAINT RAFTERS - RE: STRUCTURAL ANCHORAGE - RE: STRUCTURAL ROOF DECKING - RE: STRUCTURAL SINGLE-PLY PVC ROOF MEMBRANE, RE: A-905 SS SCREWS WITH NEOPRENE WASHER AT 48" O.C. SLOPE HORIZONTAL JOINT REINFORCEMENT WITH HOOK & EYE TYPE BRICK TIES - RE: STRUCTURAL MOISTURE BARRIER PAINT, SEALANT, TYP ALL SIDES PAINTED HOLLOW METAL DOOR & FRAME, RE: DOOR SCHEDULE GROUT SOLID DRIP CAP CMU BOND BEAM - RE: STRUCTURAL BACKER ROD & SEALANT WEEPS AT 24" O.C. 7'-4" A.F.F. LINTEL RE: STRUCTURAL REFUSE ENCLOSURE NOTES 1. ** IN THE ARCHITECTURAL DRAWINGS, REFUSE ENCLOSURE AND MAIN BUILDING MAY BE NOTED WITH FINISH SLAB AT 0'-0". ACTUAL FINISH SLAB HEIGHTS WILL VARY BETWEEN MAIN BUILDING AND REFUSE ENCLOSURE. REFER TO CIVIL FOR ALL FINISH SLAB HEIGHTS. REF. ENCLOSURE FINISHES PREFINISHED METAL COPING COLOR: MIDNIGHT BRONZE BR-A EC-1 BRICK VENEER COLOR: GLEN GERY - COURTLAND SIZE: MODULAR C2 A-103 6" DIAMETER STEEL PIPE GATE POST PIPE BOLLARDS RE: CIVIL HYDRANT - RE: PLUMBING RE: KITCHEN FOR SHELVING IN THIS AREA. STORAGE REFUSE 12' - 3 1/2" 9" 12' - 3 1/2" 8' - 4" 1' - 0"6' - 8 3/8"7 5/8"25' - 4"1' - 0" 34' - 8" 4' - 4"4' - 0"8' - 8"4' - 0"4' - 4" 1' - 0" 8' - 8" 1' - 0" 10' - 8"LOW PROFILE TURBINE ROOF VENTILATOR EQUAL TO MASTER FLOW 12" GALVANIZED STEEL INTERNALLY BRACED DUAL-BEARING ROOF TURBINE IN WEATHERED WOOD FINISH PROVIDED AND INSTALLED BY GC. COORDINATE WITH ROOFING SYSTEM FOR WEATHERTIGHT INSTALLATION. 6" 12'-5" 4 1/2" 4 1/2" 12'-5" RAMP TO DOOR MAX SLOPE 1:1251 4'-0" UNISTRUTS, TYP. 9 3/4" 9 3/4" SAW CUT - RE: CIVIL 8"x16" WALL DRAIN OPENING BELOW 1/4" / 1'-0" 0' - 6" 0' - 6" 0' - 3 3/8" 0' - 6" 0' - 6" T/ PAD T/ PAVING (SEE SECTION) 0' - 6" T/ PAD T/ PAVING (SEE SECTION) 1/4" / 1'-0" 1/4" / 1'-0" 0' - 6" 0' - 6" 0' - 6" 0' - 6" 1'-0 1/2" A2 A-103 B2 A-103 B1 A-103 C2 A-103A A2 A-103A B2 A-103A B1 A-103A A-103 E3 STORAGEREFUSE WHITE ROOFING MEMBRANE ON ROOF DECKING - RE: STRUCTURAL ON RAFTERS - RE: STRUCTURAL ON 1/2" CDX PLYWOOD CEILING - PAINT WHITE ROOFING MEMBRANE AT WALL BEYOND 1/2" EXPANSION JOINT - RE: STRUCTURAL CONCRETE SLAB - RE: STRUCTURAL CONCRETE SLAB - RE: STRUCTURAL FOR SEAL SPECIFICATIONS BLOCK FILLER WITH ONE COAT OF PRIMER & ONE COAT EPOXY PAINT TO MATCH BRICK. BOLLARD - RE: CIVIL INSTALL 4'-0" LENGTH OF UNISTRUT VERTICALLY BEHIND EACH BOLLARD - PAINT TO MATCH ADJACENT WALL 9' - 2" 7' - 10" 0' - 6" T/ EXTERIOR BOND BEAM T/ INTERIOR BOND BEAM T/ SLAB TOP OF UNISTRUT SHALL BE FLUSH WITH BOTTOM OF DRIP EDGE AT INSIDE FACE OF METAL CAP TERMINATION BAR AT EXPOSED EDGE PT-31A A-103 E2 A-103 C3 A-103 A3 D2 A-103 _____________________ D3 A-103 _____________________ C4 A-103 _____________________ T/ GRADE 0' - 0" BR-A T/ EXTERIOR BOND BEAM 9' - 2" T/ INTERIOR BOND BEAM 7' - 10" T/ SLAB 0' - 6" T/ EXTERIOR BOND BEAM 9' - 2" T/ INTERIOR BOND BEAM 7' - 10" BR-A T/ SLAB 0' - 6" T/ GRADE 0' - 0" PAINTED STEEL POST CAPS (TYP) PAINT COLLAR HINGES (TAP & ADD GREASE FITTINGS AT EACH HINGE-GREASE HINGES AFTER PAINTING) 2-1/2" X 2-1/2" PAINTED STEEL TUBE GATE FRAME - PAINT 6" DIAMETER PAINTED STEEL POST - PAINT 1-1/2" X 1-1/2" PAINTED STEEL ANGLES - PAINT 16 GA FORM DECK PANELS WELDED TO FRAME - PAINT DROP RODS BEYOND 2 EQUAL PANELS 11'-7" 12'-5" PT-113 PT-113 PT-113 PT-113 T/ GRADE 0' - 0" Chick-fil-A 5200 Buffington Road Atlanta, Georgia 30349-2998 Information contained on this drawing and in all digital files produced for above named project may not be reproduced in any manner without express written or verbal consent from authorized project representatives. CONSULTANT PROJECT # PRINTED FOR DATE SHEET SHEET NUMBER DRAWN BY REVISION SCHEDULE A 1 2 34 B C D E A B C D E 1234 CHICK-FIL-A BUILDING TYPE / SIZE: RELEASE: # 3/10/2026 11:21:17 AM Autodesk Docs://SC_05201_Dobys Bridge FSU_2026.1_FSR/05201_Dobys Bridge FSU_ARC.rvt A-103A REFUSE ENCLOSURE COLOR DESIGN 02/19/2026 Author DOBYS BRIDGE FSU 05201 FORT MILL PKWY FORT MILL, SC 29715 10-SE-05201-A-103A-REFUSE ENCLOSURE COLOR CFSC05201 25.10 P14 SE BASE FSR E+H ARCHITECTS P.C. 750 OLD HICKORY BLVD. SUITE 150-2 BRENTWOOD, TN 37027 PHONE: 615.377.3111 EMAIL: CFATEAM@EANDHARCH.COM March 12, 2026 1/2" = 1'-0" REFUSE ENCOSURE DROP ROD 3-D DECK PANEL DETAIL A3 3/4" = 1'-0" REFUSE PAD AT CONCRETE PAVING DETAIL C4 1 1/2" = 1'-0" REFUSE ENCLOSURE BASE DETAIL C3 1 1/2" = 1'-0" REFUSE ENCLOSURE DOOR JAMB DETAIL D2 1 1/2" = 1'-0" REFUSE ENCLOSURE DRIP EDGE E21 1/2" = 1'-0" REFUSE ENCLOSURE ROOF EDGE DETAIL E3 1 1/2" = 1'-0" REFUSE ENCLOSURE DOOR HEAD DETAIL D3 1/4" = 1'-0" REFUSE ENCLOSURE PLAN D1 1/2" = 1'-0" REFUSE ENCLOSURE SECTION C2 3/8" = 1'-0" REFUSE ENCLOSURE ELEVATION A2 3/8" = 1'-0" REFUSE ENCLOSURE ELEVATION B2 3/8" = 1'-0" REFUSE ENCLOSURE GATE REAR ELEVATION B1 PERSPECTIVE VIEW - REFUSE ENCLOSURE NO. DATE DESCRIPTION 03/12/2026 IFP 17 7 9 8 DO NOT ENTER DRIVE THRU DRIVE THRU ONE-WAY ONE-WAY 24.0' 18.0' 25.0' 8.0' 36.7' 25.0' 35.0' 27.6' 24.6' 43.9' 16.7' 312' 204' ONE-WAY ONE-WAY ONLY P14-SE-BASE - 5,183 SF 90 SEATS (INTERIOR) 16 SEATS (EXTERIOR 74 PARKS FFE = 657.50 7 5 14.5' 9.9' 24.0' 22.3' 25.0' 18.0' 18.0' 18.0' 9.0' 9.0' 9.0' 9.0'9.0' 7 3 18.0' 18.0' 9 6 10.0' 8 FORT MILL PARKWAY (VARIABLE R/W) PUBLIC R/W N 05°14'42" W 228.71' S 87°22'55" E 246.27' N 83°25'50" E 83.05' S 03°19'47" E 39.66' S 14°09'11" E 113.40' CURVE RADIUS ARC LENGTH CHORD LENGTH CHORD BEARING DELTA ANGLE TANGENT C1 2910.00' 430.08' 429.69'S 85°47'17" W 8°28'05" 215.43' C2 509.30' 78.33' 78.25'N 88°16'30" E 8°48'43" 39.24' C3 5210.27' 38.82' 38.82'S 15°33'13" E 0°25'37" 19.41' C1 C2 LINE BEARING DISTANCE L1 S 12°55'19" E 10.09' L1 C3 5' SETBACK 35' SETBACK 10' SETBACK (PRIVATE DRIVE) (PRIVATE DRIVE) EX. GUARD RAIL 30.0' 9.0' 9.0' 8.0' 9.0' 9.0' 5 5.0' 9.0' 18.0' 26.9' 10.0' 10.0' SIDEWALK PROPOSED BY OVERALL DEVELOPER SIDEWALK PROPOSED BY OVERALL DEVELOPER 1 1 1 1 1 12 1 1 3 3 4 4 4 4 5 5 5 5 5A 5A 5A 5A 5A 5A 5B 5B 5B 5B 6A/6H 6A/6H 1 6A 6B 20 6B 20 6B 20 6B 20 PROP. RAMP FOR TRASH ROUTE 7 7 PROP. LEVEL LANDING 6H 11 11 11 11 17 17 17 17 17 17 17 17 17 17C17D 19 21B 21B 21B 21B 21B 21B 21B 21B 21B 24 25 25 25 33 35 34 35 34 36 36 39 39 39 39 39 39 39 39 3939 39 39 39 39 40 58 58 58 58 58 41 45A 45A 45A 45A 49 50 53 55 41 41 41 20' WATER EASEMENT DO NOT ENTER DO NOT ENTER 6A/6H 45 45 36 20 20 60A 60A DO NOT ENTER R15.0' R3.0' R15.0' R3.0' R3.0' R3.0' R15.0' R15.0' R15.0' R3.5' R5.0' R3.0' R3.0' R3.0' R3.0'R3.0' R10.0' R3.0' R3.0' R3.0' R15.0' R15.0' R12.0' R3.0' R8.0' R3.0' R22.0' R3.0' R3.0' R3.0' R15.0' R20.0' R3269.0'R2874.5' R20.0' R3.5' R3.0' R3.0' R20.0' R24.0' R18.0' R29.0' R8.0' 33 PROP. CASH CART PROP. 5' CROSSWALK PROP. 3' CROSSWALK 12 2.0'10.0' 3.0'10.0' 25.0' 7 52 17D 24.4' C-2.1 SITE PLAN 1-2026 GRID NORTH 20' GRAPHIC SCALE 0 SCALE: 1" = 20' 10'20'40'60' REVISION BLOCK ISSUE REVISION DATE & DESCRIPTION 1 01/13/26 - PCR 2 02/10/26 - COMMENTS ADDRESSED 3 - 4 - 5 - 6 - 7 - ENGINEER/DESIGNER NOT RESPONSIBLE FOR COST CHANGES DURING PRELIMINARY PHASE. BIDS & QUOTES SHALL BE BASED ON PLAN SETS LABELED "ISSUE FOR BID". BIDS & QUOTES SHALL BE REVISED BASED ON PLANS LABELED "ISSUE FOR CONSTRUCTION". C I V I L E N G I N E E R I N G | L A N D S C A P E A R C H I T E C T U R E | L A N D P L A N N I N G | L A N D S U R V E Y I N G | M U N I C I P A L S E R V I C E S COPYRIGHT CARTER ENGINEERING CONSULTANTS, INC. ALL RIGHTS RESERVED. NO PART OF THIS DOCUMENT MAY BE REPRODUCED IN ANY FORM OR FASHION OR BY ANY MEANS WITHOUT PRIOR CONSENT, AGREEMENT AND WRITTEN PERMISSION FROM CARTER ENGINEERING CONSULTANTS, INC. 22028CFA 02/02/2025 OUTLOT 2, FORT MILL PARKWAY, FORT MILL, SC 29715 Sheet Job No. Date Store 1-2026 STORE #05201 #05201 CARTER ENGINEERING 1010 COMMERCE DR. BOGART, GA. 30622 P: 770.725.1200 F: 770.725.1204 www.carterengineering.com PRELIMINARY NOT APPROVED FOR BID/ CONSTRUCTION NOT FOR CONSTRUCTION Know what's below Call before you dig dial 811 SITE LOCATION MAP NOT TO SCALE SITE FORT MILL SOUTHER BYPASS WHITES ROAD DOBYS BRIDGE RD N DOBYS BRIDGE RD HOLBROOK ROAD 33 32 35 34 36 37 38 39 43CONCRETE FLUME 52TYPICAL LOCATION FOR FOUR OUTDOOR TABLES. WHEN MORE SPACE IS AVAILABLE, OUTDOOR SEATING MAY BE EXPANDED. 5 6 1 3 2 4 SITE PLAN DESIGN NOTES & KEY PLAN 44 46 45A 51 "TWO ORDER LANES" SIGN (SEE SIGNAGE PACKAGE) "LANES MERGE" SIGN (SEE SIGNAGE PACKAGE) 5A 5B 6A 6B 6C 6D 6E 6F 6G 6H 6I 6J 6K 7 CURB RAMP WITH FLARED SIDES8 CURB RAMP WITH SHORT FLARED SIDES8A RETURNED CURB ACCESSIBLE RAMP9 10 11 12 DRIVE-THRU PLAN13 DRIVE-THRU ISOMETRIC14 CONCRETE WHEEL STOP15 LANDSCAPE & IRRIGATION PROTECTOR16 SPILLING 24" CONCRETE CURB & GUTTER17A CATCHING 24" CONCRETE CURB & GUTTER CURB HEIGHT TO MATCH CONC. PAVEMENT AT DRIVE-THRU DOOR17C 17D ROLLOVER/MOUNTABLE CURB18 SCREENED REFUSE ENCLOSURE (SEE ARCH PLAN SHEET A-103)19 SCREENED REFUSE ENCLOSURE STAGGERED19A SCREENED REFUSE ENCLOSURE ALTERNATE DRAINAGE19B CONCRETE BOLLARD20 TYPICAL PAVEMENT SECTION - MEDIUM DUTY TYPICAL PAVEMENT SECTION - HEAVY DUTY 21A 21B TRANSVERSE & LONGITUDINAL CONTRACTION JOINT22 TRANSVERSE & LONGITUDINAL DOWELED CONSTRUCTION JOINT23 24 CONCRETE PAVING25 ALUMINUM HANDRAIL26 TYPICAL ADA RAMP AND HANDRAIL27 CONTRACTION JOINT28 KEYED CONSTRUCTION JOINT29 LONGITUDINAL BUTT JOINT30 EXPANSION JOINT31 RETAINING WALL WITH HANDRAIL ON TOP (HANDRAIL SIMILAR TO DETAIL 26/C-4.2) 48 40 41 42 49 EX. ASPHALT / PROP. CONCRETE INTERFACE TRANSFORMER CHICK-FIL-A PRIME SIGN (SEE SIGNAGE PACKAGE) SHORT TERM BIKE PARKING EX./PROP. CONCRETE INTERFACE EX./PROP. CURB INTERFACE THICKENED SLAB EDGE AT RAILING CORE-DRILLS PAVEMENT STRIPING AREA CLEARANCE BARS (SEE SIGNAGE PACKAGE) LANDSCAPED AREA (SEE LANDSCAPE PLAN) ROOF DOWNSPOUT (TO CONNECT TO SITE DRAINAGE SYSTEM) GREASE TRAP (SEE UTILITY PLAN) 5'x5' LANDING AND ENTRY DOOR FROST SLAB MENU BOARD LOOP DETECTION SYSTEM MENU BOARD & CANOPY ORDERING STATION PAINTED CROSS WALK MULTI-LANE DIRECTIONAL GRAPHICS 50FLAGPOLE, 30' (SEE SIGNAGE PACKAGE) LIGHT DUTY PAVEMENT RESURFACE21C 534" THICK CONCRETE STRIP BETWEEN BUILDING AND BACK OF CURB 546" THICK CONCRETE SIDEWALK BETWEEN DRIVE-THRU LANE AND BUILDING 554" WIDE PAINT STRIPE 17B 56STANDARD LIGHT POLE 45 EX./PROP. ASPHALT INTERFACE 57CURBSIDE DELIVERY SIGN (SEE SIGNAGE PACKAGE) 58CONCRETE STRIPING AREA. CONCRETE TO BE PER CONCRETE PAVING DETAIL 59CONCRETE VALLEY GUTTER 60A2' WIDE CONCRETE FLUME CONCRETE APRON @ TRASH ENCLOSURE 61CATERING & CARRY-OUT (SEE SIGNAGE PACKAGE) 62CURBSIDE DELIVERY (SEE SIGNAGE PACKAGE) 632' WIDE 4" THICK CONCRETE LANDSCAPE PROTECTION STRIP 28" CONCRETE CURB & GUTTER17 11A BICYCLE PARKING5C 60B3' WIDE CONCRETE FLUME LONG TERM BIKE PARKING 47A 47B ZEROVA AX 48 EV PARKING5D 64WALL SIGN - ICON 6.0' (SEE SIGNAGE PACKAGE) 65WALL SIGN - SCRIPT 5.0' (SEE SIGNAGE PACKAGE) 66WELCOME STAMP (SEE SIGNAGE PACKAGE) TRANSITION CURB HEIGHT W/ RAMPED CONC. PAVEMENT TO MATCH LEVEL PAVEMENT AT DRIVE-THRU DOOR PAINTED DIRECTIONAL ARROW PAINTED DRIVE-THRU GRAPHICS PAINTED STOP LINE GRAPHIC PAINTED HANDICAP PARKING SYMBOL ACCESSIBLE PARKING STALL 60° PARKING STALL @ 9' x 18' MIN. 90° PARKING STALL @ 9' x 18' MIN. DIRECTIONAL SIGNAGE (SEE SIGNAGE PACKAGE) "STOP" SIGN (SEE SIGNAGE PACKAGE) "ACCESSIBLE PARKING" SIGN (SEE SIGNAGE PACKAGE) "CIRCLE BUILDING FOR DRIVE-THRU SERVICE" (SEE SIGNAGE PACKAGE) "RIGHT TURN ONLY" SIGN (SEE SIGNAGE PACKAGE) "ONE WAY" SIGN (USE APPLICABLE DIRECTION) (SEE SIGNAGE PACKAGE) "LEFT TURN ONLY" SIGN (SEE SIGNAGE PACKAGE) "PEDESTRIAN CROSSWALK" SIGN (SEE SIGNAGE PACKAGE) "DO NOT ENTER" SIGN (SEE SIGNAGE PACKAGE) "NO PARKING" SIGN (SEE SIGNAGE PACKAGE) SIDEWALK ACCESSIBLE RAMP TRUNCATED DOMES - CAST IN PLACE (ONLY IF REQUIRED) TYPICAL CONCRETE SIDEWALK (SEE DETAIL FOR REVISIONS) TYPICAL CONCRETE SIDEWALK SECTION WITH ADDED BLACK TENT MIX FOR AREAS WITH A CROSS SLOPE TO STEEP FOR PEDESTRIAN ACCESS SIDEWALK WITH CURB & GUTTER SECTION (SEE DETAIL FOR REVISIONS) 18 7 98 DO NOT ENTER DRIVETHRU DRIVETHRU ONE-WAY ONE-WAY UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGT UGT UGT UGT UGT UGT UGT UGT UGT UGT UGT UGT UGT UGT UGT UGT UGT UGT UGT UGT UGT UGT UGT UGT UGT UGT UGT UGT UGT UGT UGT UGT UGT UGT 6''SS 6''SS 6''SS 6''SS 6''SS 6''SS 6''SS 6''SS 6''SS 6''SS 6''SS 6''SS6''SS 6''SS 6''SS 6''SS 6''SS 6''SS 6''SS 6''SS 6''SS 6''SS 6''SS 6''SS 6''SS 6''SS6''SS6''SS6''SS6''SS6''SS6''SS 35FT BUILDING SETBACK ONE-WAY ONE-WAY ONLY P14-SE-BASE - 5,183 SF90 SEATS (INTERIOR)16 SEATS (EXTERIOR 74 PARKS FFE = 657.50 7 5 73 96 8 GAS GAS GAS GAS GAS UGT UGT UGT UGT UGT UGTUGT UGT UGT UGT UGT UGT UGT UGT UGT UGT UGT UGTUGT UGT UGT UGT UGT UGT UGT UGTUGT UGT UGT UGT UGTUGT UGT UGT UGT UGT UGT UGT UGT UGT UGT UGT UGTUGT UGT UGT UGT UGTUGT UGT UGT UGT UGT UGT FH TT W W W W W WSS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS EX. 6"PVC EX. 15"RCP EX. 18"RCP EX. 18"CPP W W W W W W W W W W W W W W W W W W W W W W W W W W WWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWW FORT MILL PARKWAY (VARIABLE R/W) PUBLIC R/W (PB. E362, PG. 8 & 9) (PB. E336, PG. 8) UGT UGT UGT UGT EX. STONE BASE EX. GRAVEL OHP OHP OHP OHP OHP OHP OHP N 05°14'42" W 228.71' S 87°22'55" E 246.27' N 83°25'50" E 83.05' S 03°19'47" E 39.66' S 14°09'11" E 113.40' C1 C2 L1 EX. OVERHEAD SIGNAL APPROXIMATE LOCATIONOF EXISTING WATERLINE C3 5' SETBACK 35' SETBACK 10' SETBACK EX. 15"RCP EX. 8"PVC EX. STONE BASE EX. 15"RCP EX. 8"PVC EX. 6"PVC (A) (PRIVATE DRIVE) (PRIVATE DRIVE) POB 5 2''W 2''W 2''W 2''W 2''W 2''W 2''W 2''W 2''W 2''W 2''W 2''W 2''W 2''W 2''W 2''W2''W 2''W 4''W 4''W 4''W 4''W 4''W 4''W 4''W 4''W 4''W 4''W 4''W 4''W 4''W 4''W 4''W 4''W 4''W GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS 3/4''W3/4''W 3/4''W 3/4''W 3/4''W 3/4''W 3/4''W 3/4''W 3/4''W 3/4''W 3/4''W 3/4''W 3/4''W 3/4''W3/4''W3/4''W3/4''W3/4''W3/4''W3/4''W3/4''W3/4''W3/4''W3/4''W3/4''W3/4''W3/4''W3/4''W3/4''W3/4''W3/4''W3/4''W3/4''W3/4''W3/4''W 3/4''W 3/4''W 3/4''W 3/4''W 3/4''W 3/4''W 3/4''W 3/4''W 3/4''W 3/4''W 3/4''W 3/4''W 3/4''W 3/4''W 3/4''W 3/4''W 3/4''W 3/4''W 3/4''W 3/4''W 3/4''W 3/4''W 3/4''W 3/4''W 3/4''W 3/4''W 3/4''W 3/4''W 4''SS 4''SS 4''SS 4''SS DO NOT ENTER DO NOT ENTER DO NOT ENTER 2''W 2''W 2''W 2''W 2''W 2''W2''W UGEUGEUGE EX. MHSS TOP=653.67' IE=642.77'(IN) IE=642.56'(OUT) EX. CB EX-5 FL=653.73' IE=646.54'(IN) IE=646.47'(OUT) EX. MHSS TOP=656.23' IE=644.10'(6") IE=644.04'(IN) IE=643.86'(OU T) EX. CB EX-2 FL=654.40' IE=646.31'(A) IE=646.18'(IN) IE=646.00'(OUT) EX. IE=654.59' EX. CB EX-6 FL=655.03' IE=647.02' EX. MHSS TOP=651.62' IE=645.64'(IN) IE=645.40'(OUT) EX. GUARD RAIL EX. FH 20' WATER EASEMENT EX. CB EX-3 FL=655.61' IE=647.50' 20' WATER EASEMENT 3-Wildfire Tupelo 3-Wildfire Tupelo 84-Needlepoint Holly 16-Needlepoint Holly 40-Needlepoint Holly 5-Needlepoint Holly 3-Southern Magnolia3-Willow Oak 3-Willow Oak 3-White Fringe Tree 3-White Fringe Tree 5-Willow Oak 23-Needlepoint Holly 6-Chinese Elm 6-Natchez Crepe Myrtle 3-White Fringe Tree 13-Rose Creek Abelia 15-Rose Creek Abelia 35-Asiatic Jasmine 36-Asiatic Jasmine 45-Big Blue Liriope 40-Big Blue Liriope 11-Pink Muhly Grass Sod Sod Sod Sod Sod Sod Sod Sod Sod Sod Sod Sod Sod Sod Sod Sod Sod Sod Sod Sod Sod Sod 35-Asiatic Jasmine 12-Blue Point Juniper PERMIT PERMIT Information contained on this drawing and in all digital files produced for above named project may not be reproduced in any manner without express written or verbal consent from authorized project representatives. MLD PROJECT # PRINTED FOR DATE SHEET SHEET NUMBER DRAWN BY Chick-fil-A 5200 Buffington Road Atlanta, Georgia 30349-2998 REVISION SCHEDULE FSU# CHICK-FIL-A 2026033 2/23/26 MB DOBY'S BRIDGE FSU FORT MILL PARKWAY FORT MILL, SC 29715 05201 NO. DATE DESCRIPTION Landscape Plan L-101 BY LANDSCAPE REQUIREMENTS A. STREET TREES REQUIRED 1. Fort Mill Parkway: 430 LF / 50 = 9 street trees North: 342 LF (less 66 feet) / 50 = 7 street trees East: 212 LF / 50 = 5 street trees PROVIDED 1. Fort Mill Parkway: (3) Southern Magnolia, (6) Willow Oak = 9 street trees North: (7) Willow Oak = 7 street trees East: (5) Willow Oak = 5 street trees B. PLANTING AREA REQUIRED 1. Fort Mill Parkway: 35' setback x 430 LF = 15,050 15,050 / 2,500 = 6.02 x 2 = 12 trees 50% x 12 = 6 canopy trees 2. Fort Mill Parkway: 35' setback x 430 LF = 15,050 15,050 / 2,500 = 6.02 x 10 = 60 shrubs 50% x 60 = 30 evergreen shrubs PROVIDED 1. (6) Black Gum, (6) Chinese Fringe Tree = 12 trees (6) Black Gum = 6 canopy trees 2. (84) Needlepoint Holly = 84 shrubs (84) Needlepoint Holly = 84 shrubs PLANT SCHEDULE Symbol Qty Botanical Name Common Name Scheduled Size Remarks Trees 9 Chionanthus virginicus White Fringe Tree 2" Cal.; 10' Hgt. 6 Lagerstroemia indica 'Natchez' Natchez Crepe Myrtle 8-10' Hgt x 5-6' Spr Multi-trunked 3 Magnolia grandiflora Southern Magnolia 3" Cal.; 10' Hgt Full to ground 6 Nyssa sylvatica 'Wildfire' Wildfire Tupelo 3" Cal.; 12' Hgt. B & B; single straight leader 11 Quercus phellos Willow Oak 3" Cal.; 12' Hgt B & B; single straight leader 6 Ulmus parvifolia 'Chinese' Chinese Elm 3" Cal.; 12' Hgt Shrubs 28 Abelia x chinensis 'Rose Creek' Rose Creek Abelia 3 Gal 168 Ilex cornuta 'Needlepoint' Needlepoint Holly 24" Hgt. 12 Juniperus chinensis, 'Blue Point' Blue Point Juniper 6 Hgt. 11 Muhlenbergia capillaris Pink Muhly Grass 3 Gal. Groundcovers 85 Liriope muscari 'Big Blue' Big Blue Liriope 1 Gal Plant 18" OC 106 Trachelospermum asiaticum Asiatic Jasmine 1 Gal. Other 0 20 40 FT ATLANTIC LANDSCAPE NOTES 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. 24. 25. 26. Landscape Contractor to read and understand the Landscape Specifications prior to finalizing bids. The Landscape Specifications shall be adhered to throughout the construction process. Contractor is responsible for locating and protecting all underground utilities prior to digging. Contractor is responsible for protecting existing trees from damage during construction. All tree protection devices to be installed prior to the start of land disturbance, and maintained until final landscaping. All tree protection areas to be protected from sedimentation. All tree protection fencing to be inspected daily, and repaired or replaced as needed. No parking, storage or other construction activities are to occur within tree protection areas. All planting areas shall be cleaned of construction debris (ie. concrete, rock, rubble, building materials, etc) prior to adding and spreading of the topsoil. General Contractor is responsible for adding a min of 4” clean friable topsoil in all planting beds and all grassed areas. Graded areas to be held down the appropriate elevation to account for topsoil depth. See Landscape Specifications for required topsoil characteristics. Remove debris, gravel, rock, and media not suitable for planting from all parking lot islands. Fracture/loosen subgrade to a min. 24” depth and ensure proper drainage is achieved; complete water perk test. Add planting mix to achieve desired soil elevation; refer to landscape specifications and landscape island detail. Prior to beginning work, the Landscape Contractor shall inspect the subgrade, general site conditions, verify elevations, utility locations, irrigation, approve topsoil provided by the General Contractor and observe the site conditions under which the work is to be done. Notify the General Contractor of any unsatisfactory conditions, work shall not proceed until such conditions have been corrected and are acceptable to the Landscape Contractor. Any deviations from the approved set of plans are to be approved by the Landscape Architect. Landscaping shall be installed in conformance with ANSI Z60.1 the “American Standard for Nursery Stock” and the accepted standards of the American Association of Nurserymen. Existing grass in proposed planting areas shall be killed and removed. Hand rake to remove all rocks and debris larger than 1 inch in diameter, prior to adding topsoil and planting shrubs. Soil to be tested to determine fertilizer and lime requirements prior to laying sod. Annual and perennial beds: add min. 4 inch layer of organic material and till to a min. depth of 12 inches. Mulch annual and perennial beds with 2-3 inch depth of mini nuggets. All shrubs beds (existing and new) to be mulched with a min. 3 inch layer of mulch (mulch type to be: double shredded hardwood mulch). Planting holes to be dug a minimum of twice the width of the root ball, for both shrub and tree. Set plant material 2-3” above finish grade. Backfill planting pit with topsoil and native excavated soil. Sod to be delivered fresh (Cut less than 24 hours prior to arriving on site), laid immediately, rolled, and watered thoroughly immediately after planting. Edge of sod at planting beds are to be "V" trenched, or metal edging shall be installed if rock mulch is used; see Landscape Details. Any existing grass disturbed during construction to be fully removed, regraded and replaced. All tire marks and indentions to be repaired. Water thoroughly twice in first 24 hours and apply mulch immediately. The Landscape Contractor shall guarantee all plants installed for one full year from date of acceptance by the owner. All plants shall be alive and at a vigorous rate of growth at the end of the guarantee period. The Landscape Contractor shall not be responsible for acts of God or vandalism. See Landscape Specifications for Warranty requirements/expectations. Any plant that is determined dead, in an unhealthy, unsightly condition, lost its shape due to dead branches, or other symptoms of poor, non-vigorous growth, shall be replaced by the Landscape Contractor. See Landscape Specifications for warranty requirements/expectations. Site to be 100% irrigated in all planting beds and grass area by an automatic underground Irrigation System. Irrigation as-built shall be provided to the owners rep within 24 hours of irrigation install completion. Stake all evergreen and deciduous trees as shown in the planting detail and as per the Landscape Specifications. Remove stakes and guying from all trees after one year from planting. 19

Source: Town of Fort Mill website. First collected Oct 17, 2026.