RecordWell Data

Design Review Board — Agenda Packet

City of Spartanburg · Spartanburg County · Boards and Commissions · meeting of Oct 6, 2026 · Agenda packets

Open the original document More from City of Spartanburg

Text

Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.

Planning Department PO Box 1749 • Spartanburg, SC 29304 • phone: (864) 596-2068 email: planning@cityofspartanburg.org • website: www.cityofspartanburg.org Agenda Design Review Board (DRB) October 6, 2026 at 5:30 PM Dr. TK Gregg Community Center 650 Howard St. Spartanburg, SC 29303 I. Roll Call II. Freedom of Information Act Compliance – Public notification of the meeting has been published, posted, and mailed in compliance with the Freedom of Information Act and requirements of the City of Spartanburg Zoning Ordinance. III. Rules and Procedures for Meeting Conduct IV. Approval of Agenda V. Disposition of Minutes of September 1, 2026 meeting VI. Old Business: None VII. New Business: a. DRB-26-020-00004 — The Design Review Board (DRB) has received a request for Preliminary Conceptual Approval of a commercial renovation and approximately 650-square-foot rear addition at 130 Archer St (Tax Map Sheet: 7-12-10-039.00), with a zoning designation of D-T6 (Downtown Urban Core). Owner/Applicant: Lamar Baehr VIII. Staff Announcements IX. Adjournment Planning Department PO Box 1749 • Spartanburg, SC 29304 • phone: (864) 596-2068 email: planning@cityofspartanburg.org • website: www.cityofspartanburg.org Meeting Minutes of the Design Review Board (DRB) Tuesday, September 1, 2026, at 5:30pm Dr. TK Gregg Recreation Center Attendance Board Members Present • Jean Crowther, Chair • Lukas Hauser, Vice Chair • Danny Balon • Brian Sanders • Gwen Sollenberger Staff Present • Fredalyn Frasier, Planning Director • Dominick Calace, Planner I Others Present • Joseph Schwarz, New Ground • Andrew Ackley, Seamon Whiteside • Members of the public Call to Order Chair Crowther called the regular meeting of the Spartanburg Design Review Board to order at 5:30 p.m. A quorum was established. Chair Crowther welcomed Gwen Sollenberger to her first meeting as a Board member. Public notice and meeting procedures were reviewed. Approval of Agenda On a motion by Mr. Sanders and seconded by Mr. Balon, the agenda was approved by a vote of 5-0. Approval of Meeting Minutes (August 4, 2026) On a motion by Mr. Balon and seconded by Mr. Sanders, the minutes of the May 5, 2026 meeting were approved by a vote of 5-0. Old Business: No old business was presented. New Business: DRB-26-02000003 – Carolina Foothills Credit Union Branch – Full and Final Approval The Board considered a request for Full and Final Approval for the proposed Carolina Foothills Credit Union branch located at 520 North Church Street in the DT-5 Downtown Urban Center zoning district. Prior to presentation of the item, Mr. Balon recused himself due to SeamonWhiteside’s involvement in the project, and Ms. Sollenberger recused herself due to BLE’s involvement in the project. Planning Department PO Box 1749 • Spartanburg, SC 29304 • phone: (864) 596-2068 email: planning@cityofspartanburg.org • website: www.cityofspartanburg.org Applicant Presentation • Joseph Schwarz of New Ground presented the revised proposal for a 2,300-square-foot Carolina Foothills Credit Union branch at the intersection of North Church Street and Parsonage Lane. • The applicant summarized the revisions made since Preliminary Conceptual Approval, including items related to access, signage, the walk-up ATM, and streetscape design. • The North Church Street driveway access remained part of the proposal, consistent with the Board’s prior discussion during preliminary review. • The applicant stated that the previously discussed walk-up ATM along North Church Street was not included in the current plans. The credit union may consider a pedestrian-oriented ATM in a future phase, but raised concerns about liability, security, and the current condition of the surrounding area. • The applicant revised the wall signage to reduce the overall amount of signage on the building. One previously proposed sign was removed, while the primary signage along North Church Street and other selected elevations remained. • The applicant stated that sidewalks and streetscape areas were revised in response to comments from the Board and staff. The plans now show an eight-foot sidewalk along Parsonage Lane and an eight-foot walkway along the rear frontage, with a four-foot landscape strip where feasible. • The applicant stated that the revised streetscape was intended to better support pedestrian activity while responding to site constraints. Public Comments Chair Crowther opened the public comment period. No members of the public spoke in favor of or in opposition to the request. On a motion by Mr. Hauser and seconded by Mr. Sanders, the public comment period was closed unanimously. Board Deliberation and Staff Comments • Mr. Sanders noted the widened sidewalk along Parsonage Lane and stated that the change was appreciated, as the Board and staff had previously encouraged the applicant to better meet the Downtown Code streetscape standards. • Mr. Sanders asked about the existing tree near the Parsonage Lane and Magnolia Street corner. Andrew Ackley of SeamonWhiteside stated that the tree is identified for removal, but because it is a legacy tree, additional analysis and City approval will be required before removal. He stated that the applicant intends to meet applicable replacement and canopy requirements through additional plantings. • Mr. Sanders also asked about the proposed relocation of existing understory trees from North Church Street. The applicant’s team stated that the trees would be evaluated for relocation and long-term viability. If relocated trees do not survive, the project will need to provide replacement trees that meet City requirements. • The Board discussed the requested streetscape exception along Parsonage Lane. The applicant’s team explained that the Downtown Code requires the six-foot planting strip or tree wells to be located between the curb and sidewalk, but the site design places the planting area behind the sidewalk due to building placement and service-access constraints. • The applicant’s team stated that the revised design provides a substantial planting area behind the sidewalk and represents the best feasible response to the streetscape requirement without shifting the building farther north along North Church Street. Planning Department PO Box 1749 • Spartanburg, SC 29304 • phone: (864) 596-2068 email: planning@cityofspartanburg.org • website: www.cityofspartanburg.org • Mr. Hauser expressed support for the revised signage and stated that removing the additional sign improved the appearance of the building from that angle. • Mr. Hauser continued to express concern that pedestrians may attempt to use the drive-up ATMs, particularly as pedestrian activity increases between Wofford, the Montgomery Building, nearby residential development, and future development sites. He encouraged the applicant to continue considering a pedestrian-oriented ATM location in the future. • The applicant stated that a future in-wall pedestrian ATM could potentially be accommodated along the North Church Street frontage near the service center, but the credit union was not prepared to include it in the current plans due to security and liability concerns. • Chair Crowther stated that the requested streetscape exception along Parsonage Lane appeared reasonable given the street context. She noted that Parsonage Lane is a short segment that does not continue beyond Magnolia Street, and the alternative planting-strip location would not create an issue inconsistent with the character or function of the street. • Chair Crowther also expressed appreciation for the applicant’s work to provide the requested sidewalk width and improved Church Street frontage. • Planning staff did not provide additional comments before the Board proceeded to a motion. Motion On a motion by Mr. Hauser, seconded by Mr. Sanders, the Design Review Board granted Full and Final Approval for the Carolina Foothills Credit Union branch, including approval of the requested streetscape exception along Parsonage Lane related to the location of the required planting strip or tree wells. The motion passed unanimously, with Mr. Balon and Ms. Sollenberger recused. Staff Announcements • Staff announced that the Planning Commission would consider a proposed text amendment to the Downtown Code on September 17, 2026, to expand the Design Review Board from five members to seven members. Staff stated that the proposed expansion would bring the DRB closer in size to the City’s other boards and provide additional design input. • Board members expressed general support for the proposed expansion, noting that additional members could help maintain quorum when members are absent or must recuse themselves due to professional conflicts. Board members also noted the importance of avoiding overrepresentation from any single firm or discipline. • Staff stated that the proposed expansion would likely include one additional technical member and one community representative, and that the City intends to identify viable candidates before expanding the Board. • Staff announced that a continuing education session would be hosted at Fire Department Headquarters on September 24, 2026, from 4:00 p.m. to 6:00 p.m. The session will address evidentiary hearings and appeals, including a case from Greenville County. • Staff welcomed Gwen Sollenberger as a new Board member. Ms. Sollenberger introduced herself as a licensed professional engineer with experience in civil and geotechnical engineering and stated that she leads her firm’s Spartanburg office. Planning Department PO Box 1749 • Spartanburg, SC 29304 • phone: (864) 596-2068 email: planning@cityofspartanburg.org • website: www.cityofspartanburg.org Adjournment On a motion by Mr. Balon and seconded by Mr. Hauser, the meeting was adjourned unanimously at 6:06 p.m. ____________________________ Jean Crowther, Chair Planning Department Design Review Board Meeting 10.06.2026 130 Archer Street Commercial Renovation & Addition DRB Preliminary Review Planning Department Phone: (864) 596-2068 | email: planning@cityofspartanburg.org website: www.cityofspartanburg.org DATE September 29, 2026 PROJECT/ADDRESS/ TAX ID 130 Archer St Commercial Renovation & Addition / 7-12-10-039.00 TO Design Review Board Members PROJECT NUMBER DRB- 26-02000004 REVIEW STATUS – Preliminary Review COPIES TO City Departments/Applicant STAFF Fredalyn M. Frasier, Planning Director Dominick Calace, Planner I GENERAL PROJECT OVERVIEW The proposed project includes the interior and exterior renovation of the existing single-story commercial building located at 130 Archer Street and the construction of an approximately 650-square-foot, single-story addition at the rear of the building. The property will maintain its existing commercial use. Site grading and finished floor elevations will remain unchanged. Exterior improvements include replacement of the existing windows with new commercial windows, cleaning and painting of the existing brick masonry façade, and installation of new site landscaping. The proposed rear addition will be constructed of brick and painted to match the existing building. AUTHORITY & APPLICABILITY This parcel is zoned D-T6. The proposed project is a partial expansion (25-50% of total floor area) of an existing building. In accordance with Section 2.2.3, compliance with the Downtown Code is required for all areas of the expanded building only and the landscaping requirements of Section 8 to the extent practical. Formal design review and approval by the Design Review Board is required. DETERMINATION OF COMPLETENESS Application is complete. EXCEPTIONS REQUIRED • 3.3.4 Building Height: To permit the proposed single-story rear addition where a minimum building height of two stories is required in the D-T6 zoning district. CODE REVIEW Deficiencies noted, or exceptions or deviations required, are noted in blue italics A. Use Standards: The proposed use is an office. This use is permitted by right. B. District Standards: • 3.3.1 Lot Configuration: Compliant • 3.3.2 Primary Building Standards: Compliant • 3.3.3 Accessory Building Standards: Not Applicable • 3.3.4 Building Height: 2 stories minimum – Exception Required • 3.3.5 Permitted Parking Location: Existing Condition – not affected by proposed addition Planning Department Design Review Board Meeting 10.06.2026 130 Archer Street Commercial Renovation & Addition DRB Preliminary Review Planning Department Phone: (864) 596-2068 | email: planning@cityofspartanburg.org website: www.cityofspartanburg.org • 3.3.6 Building Frontage: Existing – no change proposed C. General Standards: Not Applicable D. Lot/Site Standards: • 5.1.1 Lot Frontage: All lots must front on a street, square, or common open space – Compliant • 5.1.2 Corner Lots: Buildings located at street intersections must place the main building, or part of the building, at the corner – Compliant • 5.1.3 Pedestrian Entries from Frontage Line: Compliant • 5.1.4 Setbacks: Compliant • 5.1.5 Adjacent Lots: Compliant E. Utilities and Trash Containment: • 5.2.1 Underground Utilities: Compliant • 5.2.2 Solid Waste Storage Areas: Solid Waste Disposal by Roll Cart Service, storage behind building – Compliant • 5.2.3 Mechanical and Utility Equipment: Compliant F. Building Standards: • 6.1.1 General Design Principles - Connectivity: Compliant • 6.1.2 General Design Principles - Housing: Not Applicable • 6.1.3 General Design Principles – Mixed-Use Infill & Redevelopment: Compliant • 6.1.4 General Design Principles - Downtown Should be Urban: Compliant • 6.1.5 General Design Principles - Put People First: Compliant • 6.2 Required Building Design Standards: o 6.2.1 Architectural Style: Compliant o 6.2.2 Compatibility: Compliant o 6.2.3 Proportions: Compliant o 6.2.4 Wall Materials: Compliant o 6.2.5 Façade Treatment: Compliant o 6.2.6 Building Entrances: Not Applicable • 6.4 Specific Building Design Standards: Mixed-Use and Commercial Buildings in D-T5 & D-T6 o 6.4.1 Roof and Eaves: Compliant o 6.4.2 Canopies/Awnings: Compliant o 6.4.3 Encroachments: Compliant o 6.4.4 Ground Level Detailing: a. Minimize Blank Walls: Compliant b. Ground Level Glazing: Compliant c. Transparency Zone: Compliant o 6.4.5 Materials: Compliant G. Parking: • 7.1.1 General Design Standards: Compliant • 7.1.2 On-Street Parking: Not Applicable • 7.1.3 Interconnected Parking Lots: Not Applicable • 7.1.4 Parking Area Access: Existing Condition – not affected by proposed addition • 7.2 Bicycle Parking: Two (2) bicycle parking spaces proposed – Compliant Planning Department Design Review Board Meeting 10.06.2026 130 Archer Street Commercial Renovation & Addition DRB Preliminary Review Planning Department Phone: (864) 596-2068 | email: planning@cityofspartanburg.org website: www.cityofspartanburg.org H. Streetscape and Site Landscaping: • 8.1 Required Streetscape: Existing Condition – not affected by proposed expansion o D-T6: 16ft sidewalk with tree wells. • 8.2 Parking Area Landscaping: • 8.2.1 Required Plantings: One (1) shade tree and eight (8) shrubs required per 10 parking spaces. Two (2) shade trees and eleven (11) shrubs provided – Compliant • 8.2.2 Parking Area Screening: Shrubs are proposed along the parking area and must be maintained at a minimum height of three feet – Compliant • 8.3 Streetscreens: Not Applicable • 8.4 Fences: Not Applicable I. Signage: Not Applicable ADDITIONAL COMMENTS AND SUGGESTIONS FOR BOARD CONSIDERATION The property contains several existing site conditions that do not conform to current D-T6 standards, including the existing streetscape, parking location, and parking access. These conditions are not created by the proposed expansion. Pursuant to Section 2.2.3, landscaping requirements are applicable to the extent practical. The applicant proposes additional shade trees and shrubs along the parking area, improving the existing site landscaping and screening. Due to the location of the existing building and parking area, achieving the full 16-foot D-T6 streetscape is not practical as part of the proposed project. RECOMMENDATION The following exceptions are required for Preliminary Approval: 1. 3.3.4 Building Height: To permit the proposed single-story rear addition where a minimum building height of two stories is required in the D-T6 zoning district. SPARTANBURG COUNTYPUBLIC DEFENDER OFFICEDEED BOOK 64 C, PAGE 724TAX MAP 7-12-06-037.00 PIERCE - PARRIS, LLC DEED BOOK 119 L, PAGE 74 TAX MAP 7-12-06-038.00 ARCHER STREET, INC. DEED BOOK 91 Y, PAGE 175 TAX MAP 7-12-06-049.00 ARCHER STREET, INC. DEED BOOK 91 Y, PAGE 175 TAX MAP 7-12-10-041.00 ARCHER STREET, INC. DEED BOOK 91 Y, PAGE 175 TAX MAP 7-12-10-042.00 N 60°12'22" E 59.14' N 58°33'03" E 82.09' N 60°16'20" E 67.30' S 60°15'56" W 67.66' S 30°52'36" E 83.14' S 31°05'45" E 100.00' S 31°11'00" E 116.52' L1L2 L3 L4 L5 L6 L7 # 4 REBAR 3/8" ROD FOUND NORTH 1,136,296.14EAST 1,719,973.037/8" BAR FOUND 1/2" RODFOUND # 4 REBARFOUND MAG NAILFOUND MAG NAILFOUND PK NAILFOUND1/2" PIPEFOUND 1/2" PIPEFOUND 1/2" PIPEFOUND 1/2" PIPEFOUND # 4 REBAR FOUND # 4 REBAR FOUND # 4 REBAR FOUND CURB / GUTTER GUY CONCRETE SIDEWLK COURTYARD 15' ALLEY - OPEN N 61°27'55" E 60.47' N 29°39'32" W 81.92' PAVED SURFACE 2 STORY BRICK BUILDING 150 ARCHER ST. ARCHER STREET 32' R/W 20' PAVED AD POWER FOUND S 60°19'01" W 83.47' N 29°00'14" W 84.93' 3/8" REBARFOUND N 61°58'42" E 20.28' # 3 REBAR FOUND BRICK WALL ONE STORY BRICK BUILDING130 ARCHER STREET LAMAR HOLDINGS, LLC DEED BOOK 146 D, PAGE 158 TAX MAP 7-12-10-040.00 LAMAR HOLDINGS, LLC DEED BOOK 146 D, PAGE 158 TAX MAP 7-12-10-040.00 EXISTING STORAGE BUILDING LS DEVELOPMENT OF SPARTANBURG, LLC DEED BOOK 124 U, PAGE 158 TAX MAP 7-12-10-038.00 LS DEVELOPMENT OF SPARTANBURG, LLC DEED BOOK 124 U, PAGE 158 TAX MAP 7-12-10-037.00 SPARTANBURG, SOUTH CAROLINA EXISTING SITE 8/18/26 130 ARCHER STREET 0 SCALE: feet 102030 1" = 10'L1 DEVELOPMENT INFORMATION DEVELOPER: LAMAR HOLDINGS, LLC 753 E. MAIN STREET, SUITE 5 SPARTANBURG, SC. 29302 TRANSECT ZONE: DT-6 TAX PARCEL # : 7-12-10-039.00 LOT SIZE: +/- .16 ACRES GRADING SUMMARY: EXISTING TOPOGRAPHY TO REMAIN UNCHANGED FINISHED FLOOR LEVEL TO REMAIN UNCHANGED SITE AREIAL EXISTING BUILDING FRONT FACADE - NORTH EXISTING BUILDING REAR - SOUTHWEST SCALE: 1" = 10' L2LANDSCAPE AND SITE PLAN # SPARTANBURG, SOUTH CAROLINAPHOTO BOARD - EXISTING CONDITIONS8/18/26 130 ARCHER STREET 0 SCALE: feet 102030 1" = 10' ADJACENT BUILDING - EASTADJACENT BUILDING WEST HISTORIC AERIAL - EASTHISTORIC AERIAL - SOUTH HISTORIC AERIAL - SOUTH ENLARGEMENT ARCHER STREET - EAST ARCHER STREET - WEST L2 N 60°16'20" E 67.30'S 60°15'56" W 67.66' S 30°52'36" E 83.14' S 31°05'45" E 100.00' L5 COURTYARD N 61°27'55" E 60.47' N 29°39'32" W 81.92' 2 STORY BRICKBUILDING 150 ARCHER ST. ARCHER STREET32' R/W20' PAVED S 60°19'01" W 83.47' N 29°00'14" W 84.93'N 61°58'42" E20.28' BRICK WALL ONE STORY BRICK BUILDING130 ARCHER STREET LAMAR HOLDINGS, LLCDEED BOOK 146 D, PAGE 158 TAX MAP 7-12-10-040.00 LAMAR HOLDINGS, LLCDEED BOOK 146 D, PAGE 158 TAX MAP 7-12-10-040.00 9.00' 12.00' 18.00' 18.00' 5 PROPOSED BUILDINGADDITION 3 18.00' 18.00' 24.00' 9.00' 9.00' 3.00' 6.00'7.55' 6.00' 7.80' 2.31'4.03' LS DEVELOPMENT OFSPARTANBURG, LLCDEED BOOK 124 U, PAGE 158TAX MAP 7-12-10-038.00 LS DEVELOPMENT OFSPARTANBURG, LLCDEED BOOK 124 U, PAGE 158TAX MAP 7-12-10-037.00 LOW WALL FOR WF DRAIN 70'-0 1/4" 12'-10 1/16"9'-11 1/2"10'-5 7/16"10'-3 3/16"10'-6 3/16" 17'-2 5/8" 24'-1 1/4" 32'-10 1/4" 8'-9" 11" 11" 5 1/2"9'-6 5/8" 15'-4 5/8" 5'-5"7'-6"5'-2" 6'-0"6'-5"3'-9"4'-3" 9'-5 1/2"4 1/2"5'-5"4 1/2"10'-7" 5'-0 1/4" 6 1/2" 5'-0 1/4" 12'-0"5'-0" 7'-8"5 1/2"9'-0" 6'-7 1/2" 37'-2" 11" 40'-10" DENOTES TO CLOSEEXISTING OPENINGS 2 2 2 3 3 2 23 32 2 2 2 4 4 1 D D 1'-0"SLOPE NEW ROOF @ 1/4" / FT 10'-0"CLG. HT. NEW STOREFRONT WINDOWSTO MATCH REPLACEDWINDOWS ON EXISTINGBUILDING. REPLACE WINDOWS ONEXISTING BUILDING w/ NEWSTOREFRONT WINDOWSNEW STOREFRONT DOOREXISTING NEWAND SIDELIGHTS NEW GUTTER ANDDOWNSPOUTSNEW STOREFRONT WINDOWSTO MATCH REPLACEDWINDOWS ON EXISTINGBUILDING. NEW STOREFRONT WINDOWSTO MATCH REPLACEDWINDOWS ON EXISTINGBUILDING.REPLACE WINDOWS ONEXISTING BUILDING w/ NEWSTOREFRONT WINDOWSNEW EXISTING 2 X 10'S @ 16' OCw/ 2 ROWS BLOCKINGSLOPE @ 1/4" / FT. 2, 2 X 12's HEADER SLOPE 1/4" / FT2 X 10 LEDGERBOLTED TO EXIST WALLw/ 1/2" AB"s @ 2' OC SLOPE TO MEETNEW RAFTERS PARKING PLAN- 8 SPACES PROVIDEDSITE UTILITIES PLAN- ALL SITE UTILITIES EXISTINGSOLID WASTE MANAGEMENT PLAN- ALL SOLID WASTE DISPOSAL BY ROLL CART SERVICE. NO OUTSIDEDUMPSTER. ROLL CART STORAGE TO BE BEHIND EXISTING BUILDING BASED ON CITY OF SPARTANBURG,SC DOWNTOWN CODE8.1 REQUIRED STREETSCAPEA.DT-6: 16' STREETSCAPE ZONE (MIN)(MEASURED FROMBACK OF CURB TO OUTSIDE EDGE OF RIGHT-OF-WAY)·16' STREETSCAPE ZONE REQUIRED·16' STREETSCAPE ZONE PROVIDED B. 16' SIDEWALK WIDTH (min)·16' SIDEWALK REQUIRED·16' SIDEWALK PROVIDED C. PLANTER TYPE AND MINIMUM WIDTH·TREE WELLS ONLY REQUIREDD.STREET TREES·TREES SHALL BE A SPECIES WITH SHADECANOPIES THAT, AT MATURITY, REMAIN CLEAROF BUILDING FRONTAGES·CANOPY TREES PROVIDED8.2 PARKING AREA LANDSCAPING8.2.1 REQUIRED PLANTINGS·ONE (1) SHADE TREE AND EIGHT (8) SHRUBSPER 10 PARKING SPACES. ALL SPACES WITHIN60 FEET OF A CANOPY TREE.·8 PARKING SPACES PROPOSED·2 CANOPY TREES PROVIDED·11 SHRUBS PROVIDED8.2.2 PARKING AREA SCREENING·ALL PARKING AREAS VISIBLE FROM THERIGHT-OF-WAY SHOULD BE SCREENED FROMVIEW·6 SHRUBS PROVIDED FOR SCREENING CODEDESCRIPTIONQTYDETAIL 32 EXTERIOR IMPROVEMENTSTRIPLE HAMMERED HARDWOOD MULCH (3" THICK)5.16 CY SITE FURNISHINGSANOVA CIRCLEBRCIRCLE POWDER COATED BIKE RACK, SURFACE MOUNT. 32IN.H X6IN.W X 36IN.L\NBIKE RACK: BLACK GLOSS 1 32-06 S-103 REFERENCE NOTES SCHEDULE SCALE:1" = 10'1LANDSCAPE AND SITE PLANL3SCALE:1/8" = 1'8WEST ELEVATIONL3 SCALE:1/8" = 1'4NORTH ELEVATIONL3 SCALE:1/8" = 1'7EAST ELEVATIONL3 SCALE:1/8" = 1'2FLOORPLANL3 CODEQTYBOTANICAL / COMMON NAMECONTCAL TREESCAR COL1CARPINUS BETULUS 'COLUMNARIS' / COLUMNAR EUROPEAN HORNBEAM-2"CAL ULM CKV2ULMUS PARVIFOLIA 'SMALL FRYE' / SMALL FRYE LACEBARK ELMB & B2" CAL. CODEQTYBOTANICAL / COMMON NAMECONTSIZE SHRUBSDIS MNV8DISTYLIUM X 'PIIDIST-V' / FIRST EDITIONS® CINNAMON GIRL® DISTYLIUM3 GAL ILE SCD11ILEX VOMITORIA `SCHILLINGS DWARF` / DWARF YAUPON HOLLY3 GAL TER BRO9TERNSTROEMIA GYMNANTHERA 'CONTHERY' / BRONZE BEAUTY™ CLEYERA5 GAL THU NOP1THUJA OCCIDENTALIS `NORTH POLE` / NORTH POLE ARBORVITAE7 GAL PLANT SCHEDULE SCALE:1/8" = 1'6SOUTH SITE ELEVATIONL3 SCALE:1/8" = 1'3ROOF PLANL3SCALE:N.T.S.5SOUTH FACADE ELEVATION RENDERINGL3 L3 SPARTANBURG, SOUTH CAROLINAPROPOSED SITE AND LANDSCAPE PLAN8/18/26 130 ARCHER STREET 0 SCALE: feet 102030 1" = 10' 5 gal - 9TER BRO 7 gal - 1THU NOP 3 gal - 6ILE SCD 3 gal - 5ILE SCD 3 gal - 8DIS MNV B & B - 1ULM CKVB & B - 1ULM CKV - - 1CAR COL S-103 City of Spartanburg Design Review Board Submittal Project: 130 Archer Street Commercial Renovation and Addition Date: August 18, 2026 Part I: Project Description & Narrative Tax Parcel # : 7-12-10-039.00 Lot Size: +/- .16 Acres Project Overview The proposed project involves the comprehensive interior and exterior renovation of the existing single-story commercial property located at 130 Archer Street in the City of Spartanburg, alongside a single-story rear addition. The property will maintain its commercial use, contributing to the continued economic vitality and pedestrian-friendly scale of the surrounding neighborhood. Site grading and finished floor Levels to remain unchanged. Exterior Renovations The design intent for the exterior renovation is to refresh and modernize the building while respecting its original architectural character. The primary exterior scopes of work include: • Window Replacement: All existing windows will be removed and replaced with new, high-quality commercial-grade windows. The new fenestration will match the profiles, sightlines, and general configuration of the existing windows to maintain the historical rhythm of the facade. • Facade Treatment: The existing brick masonry facade will be carefully cleaned and painted in a tasteful neutral or earth-tone palette. This treatment will revitalize the building's aesthetic, providing a cohesive and updated appearance while preserving the natural texture of the masonry. Proposed Addition To accommodate the operational needs of the commercial space, a new single-story addition is proposed at the rear of the property. • Scale and Massing: The addition will encompass an area approximately equal to 43% of the current building’s square footage. By locating the addition at the rear, the primary street-facing facade and the original scale of the building along Archer Street are preserved. • Materials: The exterior of the rear addition will be constructed of brick masonry. The new brick will be carefully selected, painted and detailed to seamlessly match the existing building, ensuring a unified architectural expression from front to back. Interior Renovations The interior of the building will undergo full renovations to modernize the floor plan, upgrade building systems, and create a highly functional commercial environment that complies with all current building and accessibility codes. Part II: Discretionary Modification Requests As part of this Design Review Board application, the applicant respectfully requests a Discretionary Modification regarding the streetscape requirements mandated by the City of Spartanburg Downtown Code. Request 1: Variance on Required Streetscape Sidewalk Width and Planter Type Code Section: City of Spartanburg Urban Code, Transect Zone DT-6, Section 8.1: Required Streetscape Requirement: Section 8.1 establishes specific dimensional requirements for streetscapes, including minimum sidewalk widths for properties located within the DT-6 transect, which typically call for expanded pedestrian zones and specific planter types such as tree wells. Proposed Modification: We request a variance to maintain and preserve the existing 6-foot typical sidewalk width along the North side of Archer Street across the property frontage, rather than expanding the hardscape to the DT-6 prescribed width. Additionally, we request a modification to the required "planter type. " In lieu of the code- prescribed tree wells within the hardscape, we propose installing a continuous planter bed located immediately behind the 6-foot sidewalk. This proposed planter bed will be approximately 7'6" wide. When combined with the existing 6-foot sidewalk, this configuration effectively provides a total dedicated streetscape width of 13'6" . Written Justification: 1. Maintenance of Neighborhood Character: The existing architectural and urban character of Archer Street is defined by its historic, intimately scaled streetscape. The current standard for the North side of Archer Street is a 6-foot typical sidewalk width. Expanding the sidewalk hardscape solely at the 130 Archer Street frontage would create an inconsistent, staggered, and disjointed pedestrian experience. 2. Contextual Constraints: Archer Street is currently configured as a narrow, 20-foot paved roadway. Forcing a wider DT-6 hardscape profile onto this specific parcel is disproportionate to the existing right-of-way and the established physical realities of the street. 3. Enhanced Green Space Over Hardscape: By placing a generous 7'6" planter bed behind the preserved 6-foot sidewalk, we are meeting the spirit of the Urban Code’s expanded streetscape goals without disrupting the historic curb line. This solution provides a 13'6" total functional streetscape width, vastly improving the ecological value, stormwater absorption, and visual softening of the site compared to standard tree wells cut into a wide concrete sidewalk. 4. Pedestrian Experience: Maintaining the 6-foot width ensures a continuous, safe, and predictable path of travel for pedestrians moving along the block, while the lush 7'6" planter bed will provide a highly attractive, pedestrian-friendly edge to the property. Code Compliance Statement While a modification is requested for the sidewalk width and planter type under Section 8.1, the applicant is committed to enhancing the site's ecological and aesthetic value in full accordance with the City of Spartanburg Urban Code landscaping standards. Please note that the proposed site plan and landscape plan will fully comply with the following sections without the need for modification: • Section 8.2.1: Required Plantings • Section 8.2.2: Parking Area Screening By adhering strictly to the planting and screening requirements within our proposed 7'6" planter bed and along the parking areas, the project will successfully buffer vehicular areas and introduce appropriate, high-quality greenery, elevating the quality of the Archer Street streetscape while remaining sensitive to its existing dimensional constraints.

Source: City of Spartanburg website. First collected Oct 17, 2026.