RecordWell Data

Board of Architectural Design and Historic Review — Agenda Packet

City of Spartanburg · Spartanburg County · Boards and Commissions · meeting of Dec 11, 2025 · Agenda packets

Open the original document More from City of Spartanburg

Text

Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.

The City of Spartanburg Board of Architectural Design & Historic Review City of Spartanburg | Board of Architectural Design & Historic Review 1 AGENDA December 11, 2025, at 5:30 P.M. Spartanburg County Council Chambers 366 N. Church Street – Spartanburg, SC 29303 (Please Note: Items as they appear on the Docket may or may not be considered in the order as they are presented. The Chairman will announce any changes after the roll call) I. Call To Order. II. Roll Call. III. Freedom of Information Act Compliance – Public notification of the City of Spartanburg’s Board of Architectural Design & Historic Review meeting has been published, posted, and mailed in compliance with the Freedom of Information Act and the requirements of the City of Spartanburg’s Zoning Ordinance. IV. Rules and Procedures for Meeting Conduct. V. Approval of Agenda. VI. Disposition of Minutes from the November 13, 2025, Meeting. VII. Old Business: None. VIII. New Business: 1. COA: 25-004-00071: Certificate of Appropriateness for Major Works — 189 S Hampton Drive (TMS # 7-16-02-276.00) in the Hampton Heights Historic District. The applicant is seeking approval to install new vinyl windows. The property is located in the R-8 SFD (Single Family Residential) zoning district. Owner: Jessica Fenn / Contractor: Scott Doughman, Window Nation 2. COA: 25-004-00072: Certificate of Appropriateness for Major Works — 118 Phifer Drive (TMS # 7-08-15-259.00) in the Beaumont Mills Historic District. The applicant is seeking approval to install new vinyl windows. The property is located in the R-6 (General Residential) zoning district. Owner: Tyler & Katie Helms / Contractor: Golden Key Construction IX. Staff Updates: ACOG Continued Education and Election for new Officers. X. Adjournment. For more information, please contact the City of Spartanburg Planning Department at planning@cityofspartanburg.org or call (864) 596-2068. HARB – Meeting Minutes – 2025-11-13 Page 1 of 6 Meeting Minutes of the Board of Architectural Design and Historic Review Thursday, November 13, 2025, at 5:30 PM Spartanburg County Council Chambers The City of Spartanburg Board of Architectural Design and Historic Review (HARB ) met in County Council Chambers on Thursday, November 13, 2025, at 5:30 PM with the following members in attendance: Sylvelie Franke, Brandon Gaffney, Adib Kapasi, Julie Gilmore, Kenneth Brown, and Bill Michels. Representing the Planning Department - Fredalyn Frasier, Planning Director, Dominick Calace, Planner I. Roll Call: Mr. Michels: Bill Michels Ms. Gilmore: Julie Gilmore Mr. Brown: Kenneth Brown Mr. Kapasi: Adib Kapasi Mr. Gaffney: Brandon Gaffney (Virtually) Ms. Franke: Sylvelie Franke Ms. Franke: Freedom of Information Act Compliance – Public notification of the City of Spartanburg Board of Architectural Design and Historic Review (HARB ) this meeting has been published, posted and mailed in compliance with the Freedom of Information Act and the requirements of the City of Spartanburg Zoning Ordinance. Approval of Agenda: A motion was made by Mr. Gaffney, seconded by Mr. Brown to approve the agenda. The motion was approved with a vote of 6-0. Approval of Meeting Minutes from October 9, 2025. A motion was made by Mr. Kapasi, seconded by Mr. Brown to approve the meeting minutes as amended. The motion was approved with a vote of 6-0. Old Business: COA: 25-004-00023: Certificate of Appropriateness for Major Works – 232 Hydrick Street (TMS # 7-12-14-166.00) in the Hampton Heights. The applicant is seeking approval for new construction. The property is located in the R-8 (General Residential) zoning district. Owner: City of Spartanburg | Applicant: James White Enterprises, LLC. Project Description and History The project site is located on an approximately 7,500 square foot lot in the Hampton Heights Historic District on the west side of Hydrick Street near the intersection with West Henry Street. The site is currently vacant. The applicant proposes to build a 2,617 square foot single-family dwelling unit on the lot. The proposed residential structure is a one-and-a-half story Craftsman style home measuring 35 feet in width and 63 feet 2 inches in length, with a peak ridge height of 30 feet 8 inches. The house will be constructed on a stucco foundation with a crawl space. HARB – Meeting Minutes – 2025-11-13 Page 2 of 6 A full-width front porch measuring 9 feet in depth will span the entire facade. The porch decking will consist of painted wood tongue and groove deck boards and will be supported by brick foundations with painted wood columns. Wooden porch railings will enclose the porch and extend down the stairs. The applicant is proposing to clad the house in Hardie Plank lap siding. The windows will be black wood, six over six single hung windows with simulated divided lites. The front door is proposed to be a craftsman style mahogany-stained wood door. The roof will be comprised of architectural shingles. A split strip driveway is proposed along the side of the home with a concrete parking pad located in the rear yard. Previous Board Action This application was presented to the Board of Architectural Design and Historic Review on September 11th, 2025. The Board voted to defer action, requesting additional information regarding the siding corner detail, stucco specifications, window specifications, railing specifications, and a revised second- floor plan showing windows in the bedroom areas. Analysis Zoning Ordinance and Historic Design Manual Consistency The design guidelines are outlined in the Hampton Heights Design Guidelines for the City of Spartanburg Historic District Preservation Principles and Approaches. The purpose of the guidelines is to provide property owners with guidance for the preservation and protection of historic and architecturally valuable districts and sites in the City. The project is also subject to Section 510 of the City’s Zoning Ordinance, Historic Preservation. This section allows the Board to review applications involving historic structures and districts and issue a Certificate of Appropriateness subject to the Standards listed in the Ordinance. The project site has a zoning designation of R -8 SFD, Single Family District, which allows single family dwelling units. Section 510.6 of the City of Spartanburg Zoning Ordinance list standards for reviewing Certificate of Appropriateness. Specifically, Se ction 510.6 (C)(2) states that in reviewing applications for new construction or alteration, the Board shall consider the U.S. Secretary of the Interior’s Standards for Rehabilitation, and the five criteria listed in the findings. Normally, when a new house is proposed in most other areas of the city, only a building permit is required. However, due to the location, the proposed house is subject to Section 6.0, New Construction Guidelines, of the Historic Districts Design Manual. 6.2 Recognizing the Prevailing Character of Existing Development • Identify and respect the prevailing character of adjacent historic buildings and surrounding developments. The surrounding homes near the proposed development are predominantly bungalows in character. The proposed residence incorporates defining features of the Craftsman Bungalow style, including prominent columns and a full -width front porch. The scale and des ign of the front porch are consistent with those found on other Craftsman-style homes within the district. 6.2.1 Building Setback and Orientation: • The orientation of a new building and its site placement shall appear to be consistent with dominant patterns within the area of influence, if such patterns are apparent. The applicant's submission of the site plan indicates that the structure will be located 8 feet from the north side setback and 18 feet 4 inches from the south side setback. The structure will be HARB – Meeting Minutes – 2025-11-13 Page 3 of 6 located 10 feet from the front property line, which appears to be consistent with adjacent properties. 6.2.2 Directional Emphasis: • A new building’s directional emphasis shall be consistent with dominant patterns of directional emphasis within the area of influence, if such patterns are present. The structure will exhibit horizontal directional emphasis and face Hydrick Street, consistent with other structures on the street. 6.2.3 Shape: • Roof Pitch: The roof pitch of a new building shall be consistent with those of existing buildings within the area of influence, if dominant patterns are apparent. The roof pitch of the proposed house will be 4:12 at the front of the house and transition to 8:12 near the center of the dormer. This roof pitch is consistent with Craftsman Bungalow style homes in the district. • Porch Form: The shape and size of a new porch shall be consistent with those of existing historic buildings within the area of influence, if dominant patterns are apparent. The front porch extends along the entire length of the home’s facade, 33 feet and extends 9 feet out from the home. This porch size is consistent with other Craftsman style front porches in the district. The structure has four brick foundation columns with painted wood columns. This style is consistent with other Craftsman homes in the district. • Building Elements: The principal elements and shapes used on the front façade of a new building shall be compatible with those of existing buildings in the area of influence, if dominant patterns are apparent. The applicant is proposing a craftsman style home with symmetrical features. The door will be located in the center of the facade flanked by six-over-six wood framed simulated divided lite windows on either side. The dormer will be located in the center of the structure with two windows of the same style. The north side of the home will have a 3-foot by 14-foot bump-out addition on the first floor. The principal elements and shapes are consistent with adjacent structures and other Craftsman style homes in the historic district. 6.2.4: Massing: • The massing of a new building shall be consistent with dominant massing patterns of existing buildings in the area of influence, if such patterns are apparent. The proposed structure is a 1.5 story home. The ridge height of the proposed building is 30 feet 8 inches. The design also includes a dormer in the front of the house that will extend from the peak of the roof to the front porch. Adjacent homes on the street range in height from 1 to 2 stories. The scale and form of the structure are appropriate for the surrounding neighborhood. 6.2.5: Proportion: • The proportions of a new building shall be consistent with dominant patterns of existing buildings in the area of influence, if such patterns are apparent. There is no information in the submission that provides the proportion of the structure in relation to other structures. Based on staff observations at the project site, the proportion of the proposed structure is consistent with the design guidelines. 6.2.6 Rhythm: HARB – Meeting Minutes – 2025-11-13 Page 4 of 6 • New construction in a historic area shall respect and not disrupt existing rhythmic patterns in the area of influence, if such patterns are present. There is no information in the submission that provides the rhythm of the structure in relation to other structures. Based on staff observations at the project site, the rhythm of the proposed structure is consistent with the design guidelines. 6.2.7 Scale/Height: • New construction in historic areas shall be consistent with dominant patterns of scale with the area of influence, if such patterns are present. The structure is a 1.5 story home. The structure is 35 feet 10 inches wide, 60 feet 4 inches long, and has a peak ridge height of 30 feet 8 inches. The front porch extends along the entire front facade and will be 9 feet in depth. Adjacent homes on the str eet range from 1 to 2 stories. The proposed scale and height are consistent with adjacent homes and the design guidelines. The size of the front porch is similar to that of other properties in the surrounding area. Hampton Heights Design Guidelines Findings Certificate of Appropriateness, Section 510.6 (C) a. The character and appropriateness of the design The character of the surrounding homes can be described as bungalows. Although the housing style is not specifically mentioned in the submission, the features are typical of a Craftsman Bungalow with its prominent front porch and columns. The size and desi gn of the front porch are typical of the surrounding properties. The site plan shows a split strip driveway on the south side of the lot leading to a concrete parking pad in the rear yard. The proposed setback is 10 feet, which is consistent with adjacent structures on Hydrick Street. b. The scale of the buildings The proposed home is 1.5 stories. The structure is 35 feet 10 inches wide, 60 feet 4 inches long, and has a peak ridge height of 30 feet 8 inches. The front porch extends along the entire front facade and will be 9 feet in depth. Adjacent homes on the stre et range from 1 to 2 stories. The proposed scale and height are consistent with adjacent homes and the design guidelines. The size of the front porch is similar to that of other properties in the surrounding area. c. The texture and materials The proposed house will be clad with Hardie Plank lap siding. The material creates the appearance of wood siding, which is consistent with surrounding homes. The visible width of the siding is unclear but should not exceed 5 inches. A sample of the siding should be provided for review by staff. The applicant has also provided a siding corner detail confirming that the corners will be finished with trim pieces rather than mitered siding, consistent with historic construction methods. The front porch is proposed with painted wood columns with brick foundations. The porch decking will be painted wood tongue and groove deck boards. This material is consistent with homes in the historic district. The railing that encloses the porch and extends along the stairs will be wood. Detailed railing construction drawings were submitted to verify compliance with the design guidelines. This material is consistent with the design guidelines and adjacent homes. HARB – Meeting Minutes – 2025-11-13 Page 5 of 6 The home’s foundation will be stucco with a crawl space. The finish will consist of a ½ inch lime-based gray stucco parge coat over waterproofed CMU. This treatment is consistent with the design guidelines and visually compatible with historic foundations. The roof will have a 4:12 pitch at the front of the home which transitions to an 8:12 pitch near the center. The roof is proposed to be composed of charcoal architectural shingles. The roof material and design are consistent with the design guidelines. A craftsman style mahogany-stained door is proposed for the front of the house. This type and style of door is consistent with the historic design guidelines and other doors in the adjacent properties. The proposal shows single-hung six-over-six black wood windows with simulated divided lites. All windows are double pane glass. The drawings have been updated to show a 6- inch cedar wood finish around the windows. The window style and trim are consistent with the historic design guidelines. d. The relationship of such elements to similar features of structures in the immediate surroundings – The proposed Bungalow is an appropriate design for the site. It will match the prevailing character of the surrounding homes, most of which are some form of Bungalow. The porch is a character defining feature of the Bungalow. There are multiple structures on Hydrick Street with similar styles of front porches. It is not clear how some of the features are consistent with other character defining features in the neighborhood. No examples of existing features in the neighborhood were provided as examples for this submission. e. If the property is in a Historic District, the extent to which the alteration or construction would be harmonious with the Historic District – The structure will be similar to other homes in the neighborhood, including the front porch, windows, and doors. The siding proposed in the applicant’s site plan appears to be consistent with the building materials of surrounding homes. The construction makes use of an otherwise vacant and underutilized lot in the historic district. Staff Recommendation Staff recommends approval of the proposed design . The applicant has provided clarification on all items requested at the September 11 th, 2025 meeting, and the home is consistent with the Historic Design Guidelines for new construction. Applicant: Christopher Ceej Jefferson. Public Speakers: None. Discussion: The board recommended that the applicant revise the proposed windows from six-over-six to six- over-one for better alignment with historic character. The applicant also expressed interest in transitioning the foundation to brick. The board advised that any HardiePlank siding used should have a smooth, non-wood texture finish, and the exposure should not exceed five inches. HARB – Meeting Minutes – 2025-11-13 Page 6 of 6 A motion was made by Dr. Avery, seconded by Mr. Brown, to approve as presented with minor changes as stated above by a vote of 7 to 0. Staff Announcements: Staff announced the continuation of ACOG continuing education. All board meetings for 2026 will be held at the Dr. T.K. Gregg Community Center, located at 650 Howard Street. Housing Updates: An update was provided for 310 Spring Street, where tracks were previously installed. The property was given six months to come into compliance. A site visit confirmed the work remains incomplete, as of both April and the current date. Code Enforcement has followed up, and proceedings are underway to bring the property into compliance. An update is expected by mid-December. Officer Elections: • A motion was made by Mr. Brown, seconded by Ms. Frankie, to reappoint Bill Michels as Chair. The motion passed with a vote of 7–0. • A motion was made by Dr. Avery to nominate himself as Vice Chair, seconded by Mr. Michels. The motion also passed with a vote of 7–0. New Business: None. The meeting was adjourned at 6:04 PM. ______________________________ Bill Michels, Chairman PO Box 1749 • Spartanburg, SC 29304 • Phone: (864) 596-2068 • email: planning@cityofspartanburg.org website: www.cityofspartanburg.org Planning Department December 3, 2025 TO: The Board of Architectural Design and Historic Review RE: Certificate of Appropriateness for Major Works Address: 189 S Hampton Dr (TMS: 7-16-02-276.00) Historic District: Hampton Heights Historic District Zoning: R-8 SFD (Single Family District) Owner/Applicant: Jessica Fenn Contractor: Window Nation / Go Permits Request: The Applicant is seeking approval to install new vinyl windows ______________________________________________________________________________ Project Description and History The project site is located on an approximately 22,000 square foot lot in the Hampton Heights Historic District on the southeast corner of S Hampton Drive and Peronneau Street. The residential structure is considered a non -contributing structure within the historic district as it was constructed in 1987 prior to the adoption of the Historic District and does not reflect a historic architectural style. The Applicant is seeking approval to replace all of the windows on the structure. According to the Applicant, the existing windows are inefficient, allowing cold air into the home in winter and hot air in summer. The existing windows are one -over-one single -pane wood windows. The Applicant proposes replacing them with one-over-one double-pane vinyl windows. Photos of both the interior and exterior windows, as well as product specifications, are included in the application materials. Analysis Zoning Ordinance and Historic Design Manual Consistency The design guidelines are outlined in the Hampton Heights Design Guidelines for the City of Spartanburg Historic District Preservation Principles and Approaches. The purpose of the guidelines is to provide property owners with guidance for the preservation and protection of historic and architecturally valuable districts and sites in the City. The project is also subject to Section 510 of the City ’s Zoning Ordinance, Historic Preservation. This section allows the Board to review applications involving historic structures and districts and issue a Certificate of Appropriateness subject to the standards listed in the Ordinance. Section 510.6 of the City of Spartanburg Zoning Ordinance list standards for reviewing a Certificate of Appropriateness. Specifically, Section 510.6 (C)(2) states that in reviewing applications for new construction or alteration, the Board shall consider the U.S. Secretary of the Interior’s Standards for Rehabilitation and the five criteria listed in the findings. Hampton Heights Design Guidelines Findings Certificate of Appropriateness, Section 510.6 (C) a. The character and appropriateness of the design Section 8.1.4 Windows of the Hampton Heights Design Guidelines state s, “ Windows are very important in creating rhythm on a house and also play a role in the directional emphasis and scale of buildings. Highly decorative windows with distinctive shapes or glazing patterns are always character- defining features of buildings. Guideline: Existing windows, including window sash, glass, lintels, sills, frames, molding, shutters, and all hardware shall be retained and repaired through routine maintenance whenever possible. When deteriorated elements must be replaced, new materials shall be compatible with original materials in terms of material, design, and hardware. If it is necessary to replace an entire window, the replacement shall be sized to the original opening and shall duplicate all proportions and configurations of the original window.” • The proposed replacement windows maintain the existing one -over-one configuration and size of the original window s. The proposed material (vinyl) differs from the existing wood windows. b. The scale of the buildings • The replacement of windows will not affect the scale of the buildings. c. The texture and materials • The proposed replacement windows are vinyl, which differs in material and texture from the existing wood windows. The window openings and configuration will remain the same. d. The relationship of such elements to similar features of structures in the immediate surroundings – • Properties in the immediate surroundings of the project site appear to have wood windows. e. If the property is in a Historic District, the extent to which the alteration or construction would be harmonious with the Historic District – • The Design Guidelines require replacement windows to be compatible with the originals in material, size, and design. The vinyl material differs from the original wood windows, while the size and one-over-one design are retained. Staff Recommendation Staff recommends that approval of front-facing window replacement be conditioned on the applicant considering these alternatives to vinyl, to ensure the façade remains compatible with the historic district’s character while allowing reasonable flexibility for a non-contributing property. Fiberglass Very durable; resists warping, rot, moisture, temperature swings; low maintenance; long service life. Better chance of compatibility than vinyl: many fiberglass products can mimic wood profiles, allow paintable finishes, and have stable dimensions similar to wood. Excellent wood-look alternative Compatible with district appearance Composite / Wood- Clad Wood interior, durable exterior (aluminum, fiberglass, or vinyl-clad) Low maintenance Can be painted/ stained Often a strong compromise — retains wood window aesthetic where visible, yet easier upkeep and better durability than pure wood; many districts and preservation bodies accept clad windows as “appropriate historic looking replacements”. Popular preservation- friendly option; maintains visual character while reducing upkeep. Submitted by: Dominick Calace Planner I City of Spartanburg Planning Department Attachments: Conditions of Approval Site Map Zoning Map Site Photos Application and Materials CONDITIONS OF APPROVAL FOR THE PROJECT ON PROPERTY AT: 189 S Hampton Dr (TMS: 7-16-02-276.00) - Hampton Heights Historic District Owner/Applicant: Jessica Fenn Contractor: Window Nation 1. If one or more of the following conditions is not met with respect to all its terms, then this approval may be revoked. 2. All plans for future construction which are not covered by this review shall be submitted to the City Planning Department for review and approval. 3. Major modifications to plans or exceptions to completion may be granted only by the City authority which approved the project. 4. This permit shall be exercised within six months of the date of final approval, or it shall become null and void. Extensions may be granted with the permission of the Board. 5. A building permit shall be obtained from the Building Department prior to commencement of work. 6. The development of the site shall be in substantial accordance with the approved plans submitted and on file in the Spartanburg City Planning Department. Major modifications to plans or exceptions to completion may be granted only by the City authority whi ch approved the project. Site Map – 189 S Hampton Dr Zoning Map – 189 S Hampton Dr Site Photos – 189 S Hampton Dr Properties to the Left and Right Properties Across the Street Planning Department PO Box 1749 • Spartanburg, SC 29304 • Phone: (864) 596-2068 • email: planning@cityofspartanburg.org website: www.cityofspartanburg.org December 3, 2025 TO: The Board of Architectural Design and Historic Review RE: Certificate of Appropriateness for Major Works Address: 118 Phifer Dr (TMS: 7-08-15-259.00) Historic District: Beaumont Mills Historic District Zoning: R-6 (General Residential District) Owner/Applicant: Tyler & Katie Helms Contractor: Golden Key Construction Request: The Applicant is seeking approval to install new vinyl windows ______________________________________________________________________________ Project Description and History The project site is located on an approximately 9,700 square foot lot in the Beaumont Mills Historic District on the south side of Phifer Dr ive. The residential structure was constructed in 19 41. The architectural style designated by the Beaumont Mill Design Guidelines is House Type 13 – Gable on Hip Cottage. The Applicant is seeking approval to replace all of the windows on the structure. The Applicant has stated that the existing windows have broken panes, do not close all the way, and are inefficient, leading to high energy bills. The existing windows on the structure are six-over-six single-pane wood windows. The windows will be replaced with six-over-six simulated divided lite vinyl windows. Photos of both the interior and exterior of the windows are included, as well as the specifications for the proposed replacement units. The Applicant has noted that replacing the existing windows with new wood units would require custom fabrication and would be significantly more expensive than vinyl replacements. According to the Applicant, vinyl windows are priced between $500 –$900 per unit, while new custom wood windows begin at approximately $1,200 per unit. The Applicant states that this cost difference affects the feasibility of replacing their windows. Analysis Zoning Ordinance and Historic Design Manual Consistency The design guidelines are outlined in the Beaumont Mills Design Guidelines for the City of Spartanburg Historic District Preservation Principles and Approaches . The purpose of the guidelines is to provide property owners with guidance for the preservation and protection of historic and architecturally valuable districts and sites in the City. The project is also subject to Section 510 of the City ’s Zoning Ordinance, Historic Preservation. This section allows the Board to review applications involving historic structures and districts and issue a Certificate of Appropriateness subject to the standards listed in the Ordinance. Section 510.6 of the City of Spartanburg Zoning Ordinance list standards for reviewing a Certificate of Appropriateness. Specifically, Section 510.6 (C)(2) states that in reviewing applications for new construction or alteration, the Board shall consider the U.S. Secretary of the Interior’s Standards for Rehabilitation and the five criteria listed in the findings. Beaumont Mills Design Guidelines Findings Certificate of Appropriateness, Section 510.6 (C) a. The character and appropriateness of the design Section 8.1.4 Windows of the Beaumont Mill Design Guidelines state s, “ Windows are another significant character defining feature of any home. Wood windows were constructed so that individual pieces could be taken apart and repaired as needed. Therefore, many original windows could be repaired for much less than replacing a window. If it’s determined that the windows are in such deteriorated condition that they must be replaced, you should select a new window with extreme care. Make sure the following details should be compatible when selecting a new window: Size of window, S hape and size of sash, Window pane size and configuration, Muntin and Mullion profile shape, and Location of meeting rail . Wood and aluminum clad wood windows are the most appropriate replacement materials. Other window materials will be evaluated by the HARB.” • The proposed replacement windows maintain the six-over-six configuration and size of the original windows. The proposed material (vinyl) differs from the original wood windows and must be evaluated by the HARB. b. The scale of the buildings • The replacement of windows will not affect the scale of the buildings. c. The texture and materials • The proposed replacement windows are vinyl, which is different in material and texture from the existing wood windows. The window openings and configuration will remain the same. d. The relationship of such elements to similar features of structures in the immediate surroundings – • Properties in the immediate surroundings of the project site appear to have a combination of wood and vinyl windows. The properties to the left and right both have vinyl windows. Of the three properties across the street, two have vinyl windows, and one has wood windows. e. If the property is in a Historic District, the extent to which the alteration or construction would be harmonious with the Historic District – • The Design Guidelines require replacement windows to be compatible with the originals in material, size, and design. While the proposed windows retain the size and six -over-six configuration, the vinyl material must be evaluated for harmony with the historic district. Staff Comments Staff acknowledge the Applicant’s stated cost difference between custom wood windows and the proposed vinyl replacements. If the Board determines that the proposed vinyl windows match the size of the existing openings, retain the six-over-six configuration, and provide an acceptable sash/muntin profile, and meeting-rail alignment consistent with the Design Guidelines, approval of the replacement may be appropriate. Staff Recommendation - Denial The property is classified as a contributing structure, and staff recommends that vinyl windows not be used for replacement of windows visible from the street. • Replacement windows should maintain the original openings, proportions, muntin patterns, and trim profiles to preserve the historic integrity of the façade and the district’s character. • Historically appropriate alternatives such as wood, fiberglass, or composite/wood-clad windows. • The City may have funding or grant programs available to assist property owners experiencing financial hardship in meeting these requirements. Submitted by: Dominick Calace Planner I City of Spartanburg Planning Department Attachments: Conditions of Approval Site Map Zoning Map Site Photos Application and Materials CONDITIONS OF APPROVAL FOR THE PROJECT ON PROPERTY AT: 118 Phifer Dr (TMS: 7-08-15-259.00) - Hampton Heights Historic District Owner/Applicant: Tyler & Katie Helms Contractor: Golden Key Construction 1. If one or more of the following conditions is not met with respect to all its terms, then this approval may be revoked. 2. All plans for future construction which are not covered by this review shall be submitted to the City Planning Department for review and approval. 3. Major modifications to plans or exceptions to completion may be granted only by the City authority which approved the project. 4. This permit shall be exercised within six months of the date of final approval, or it shall become null and void. Extensions may be granted with the permission of the Board. 5. A building permit shall be obtained from the Building Department prior to commencement of work. 6. The development of the site shall be in substantial accordance with the approved plans submitted and on file in the Spartanburg City Planning Department. Major modifications to plans or exceptions to completion may be granted only by the City authority which approved the project. Site Map – 118 Phifer Dr Zoning Map – 118 Phifer Dr Site Photos – 118 Phifer Dr Properties to the Left and Right Properties Across the Street 118 Phifer Dr, Spartanburg, SC Dear Board of Spartanburg, We are writing to you regarding the urgent need to replace the windows in our historic community homes. As the current windows are broken and the winter months are fast approaching, it is imperative that we find a cost-effective and timely solution to mitigate discomfort and increase energy efficiency within the homes. After considering both wood and vinyl window options, we believe that vinyl windows are a more practical choice for several compelling reasons. **Cost Considerations** One of the most significant factors that influence our decision is cost. Vinyl windows are substantially more budget-friendly, with prices ranging from $500 to $900 per window, compared to the starting cost of $1,200 per wood window. Many of our community members are working with fixed budgets, and the lower cost of vinyl windows can provide the financial relief necessary without sacrificing quality or performance. **Durability and Maintenance** Vinyl windows offer distinct advantages in terms of durability and maintenance. Unlike wood windows, which are susceptible to chipping, cracking, and peeling due to moisture and sunlight exposure, vinyl windows are water-resistant, will not rot, and are resistant to pest infestations. Moreover, vinyl windows do not require regular painting or sealing, making them a low-maintenance option that homeowners will appreciate. **Energy Efficiency** Vinyl windows also excel in energy efficiency. They are excellent insulators and meet the Energy Star ratings for South Carolina, with a U-factor of 0.28 and SHGC of 0.23. This means that vinyl windows can significantly reduce energy costs by maintaining indoor temperatures better than wood windows, which are poor conductors of heat and cold. **Lead Time and Installation** The need for swift action cannot be overstated given the onset of winter. Vinyl windows come with a considerably shorter lead time of just 3 weeks, compared to the 3-month wait for wood windows. This time efficiency allows us to address the immediate needs of residents, ensuring that all installations are complete before the cold weather sets in. In conclusion, vinyl windows are a more cost-effective, durable, and energy-efficient option that meets the urgent needs of our community. We urge you to consider this proposal favorably to ensure the well-being and comfort of our residents this winter. Thank you for considering our proposal. Sincerely, Golden Key Construction LLC Options ○ Extension Jambs 4 9 16'' - 6 9 16'' ○ Full Screen ○ J-Channel Filler ○ Low-E & Argon Filled Glass Units ○ Pull Handle ○ Simulated Divided Lites ○ Snap-on Nail Fin ○ Window Opening Control Device PAGE: 1 of 5VERSION 06.13.25 9600 Series Double Hung Replacement ○ Stylish Bold Bevel, Frame Depth - 3 4 1'' ○ Stainless Steel Constant Force Balances ○ Continuous Head & Sill on Twin & Triple Units ○ Heavy-duty vinyl frame ○ Glazing Pocket Depth - 3 4'' ○ Watertight Full Capture Sill w/no Weep Holes Features Interior View 9600 DH 9600 DH - PW - DH 9600 DH w/PW PAGE: 2 of 5VERSION 06.13.25 9600 Series Double Hung Replacement 4 3/8'' 2 11/16'' 1 1/8'' 1 11/16'' 2 13/16'' 3 13/16''3 1/4'' 2 11/16'' 3 7/8'' 1 1/8'' 3/4'' IGU 2 5/16'' 1 9/16'' 1 1/8'' 5'' 3/4'' IGU 2 1/8'' 3 15/16'' 2 7/8'' 4 7/16'' 3/4'' IGU 3/4'' IGU 1 3/4'' 1 13/16'' 4 3/8'' 4'' 3 1/2'' 1'' IGU OPTIONAL 1 1/8'' 1/2'' 4 5/8'' 5 1/8'' 2 1/16'' 2 1/4 VERSION 06.13.25 PAGE: 3 of 5 Scale: SILL SECTION N.T.S. 3 9600 Scale: MEETING RAIL SECTION N.T.S. 2 9600 Scale: HEAD SECTION N.T.S. 1 9600 Scale: JAMB SECTION N.T.S. 4 9600 Scale: JAMB SECTION N.T.S. 4 OPP 9600 9600 Series Double Hung Replacement 1/2''2 11/16'' 4'' 1'' IGU 2 11/16'' 4'' 3 1/2'' 1'' IGU OPTIONAL 1 11/16''1 11/16'' 1/2'' 1/2'' 5 7/8'' 2 11/16'' 3 1/2'' 1'' IGU OPTIONAL 2 11/16'' 4'' 1'' IGU OPTIONAL 3 1/2'' 4'' 1/2'' VERSION 06.13.25 PAGE: 4 of 5 9600 Series Double Hung Replacement Scale: MULLION V-SECTION N.T.S. 7 9600 Scale: MULLION V-SECTION N.T.S. 8 9600 5 7/8'' 1/2''2 11/16'' 2 11/16'' 3 7/8''3 7/8'' 3/4'' IGU 3/4'' IGU 1/2'' 4 3/8'' 2 11/16'' 4'' 1'' IGU 3 1/4'' 2 11/16'' 3 7/8'' 1 1/8'' 3/4'' IGU 1 11/16'' 4 3/8'' 3 1/4'' 2 11/16'' 3 7/8'' 1 1/8'' 3/4'' IGU 1 11/16'' PAGE: 5 of 5 Scale: MULLION H-SECTION N.T.S. 6A 9600 Scale: PW SILL SECTION N.T.S. 3A 9600 Scale: PW JAMB SECTION N.T.S. 4A 9600Scale: PW HEAD SECTION N.T.S. 1A 9600 VERSION 06.13.25 9600 Series Double Hung Replacement ENERGY STAR ENERGY STAR VV7 UPDATE 7 UPDATE OCT 2023 North North Central South Central South Previous Low-E3 2023 Update Low-E7*-N Previous Low-E2 2023 Update Low-E7-NC Previous Low-E2 Solar 2023 Update Low-E7-SC Previous Low-E2 Solar 2023 Update Low-E7-S U-F† SHGC†† U-F SHGC U-F SHGC U-F SHGC U-F SHGC U-F SHGC U-F SHGC U-F SHGC ≤0.27 Any ≤0.22 ≥0.17 ≤0.30 ≤0.40 ≤0.25 ≤0.40 ≤0.30 ≤0.25 ≤0.28 ≤0.23 ≤0.40 ≤0.25 ≤0.32 ≤0.23 0.28 0.32 0.23 ≥0.35 0.29 0.37 0.24 ≥0.35 0.30 0.42 0.25 ≥0.40 0.26 ≥0.40 Low E, or low emissivity energy-effcient windows, have a thin transparent coating that reflects heat and UV light keeping the temperature in your home comfortable. Our double pane windows contain Lo-E coatings in various configurations; optimized for your designated climate zone. Optional, heavier-than-air argon gas must also be included to meet Energy Star requirements. Double Paned Glass Low E Surface 2 Low E Surface 4 *E7 = Energy Star (version 7) †U-F = U-Factor † † SHGC = Solar Heat Gain Coefficient U-Factor (UF) A rating based on how much heat is allowed to transfer through the product. The lower the U-factor, the less heat transfer occurs through a product. U-factor is particularly important during the winter heating season in colder climates. Air Leakage A rating based on how much air will enter a room thru the product. Lower number, the lower the potential for a draft. Visible Light Transmission (VL T) A rating based on how much visible light comes through a product. The higher the VTL, the higher the potential for day lighting. Solar Heat Gain Coefficient (SHGC) A rating based on how much heat from the sun is blocked. The lower the SHGC, the more a product is blocking solar heat gain. Blocking solar heat gain is particularly important during the summer cooling season in hot Southern climates. By contrast, people in Northern climates may want solar heat gain during the cold winter months to lessen the cost of heating the home. Understanding the New NFRC label 0.25 0.65 0.54 0.3 0.0 U - FACTOR VISIBLE TRANSMITTANCE 1.0 0.0 1.0 0.0 1.0 0.0 1.0 SOLAR HEAT GAIN COEFFICIENT AIR LEAKAGE Lower is Better Higher is Better Lower is Better Lower is Better in Southern Zone Higher is Better in Northern Zone Energy Code Compliance Guide to Window Selection in South Carolina Code: 2006 International Energy Conservation Code This guide is designed to help select windows, doors and skylights that will meet the requirements of the 2006 IECC for residential buildings as it relates to South Carolina. The IECC assigns the counties in the state of South Carolina into a single climate zone. The requirements vary for this zone and are detailed in the window selection requirements found on the back of this sheet. The requirements in the 2006 IECC are the same for windows used in new buildings, remodeling & additions to existing buildings, and as replacements of existing windows. Step-by-Step Instructions 1. Use the color-coded map or list of counties to locate the IECC climate zone in which construction is taking place. 2. Use the “Table of IECC Requirements for Window Selection in South Carolina” (on the back of this sheet) to determine the window performance requirements associated with the climate zone. 3. Construct the home with windows that have area weighted average U-factor and SHGC values less than or equal to the values for the climate zone and meet the code maximum air leakage requirements. IECC CLIMATE ZONE 3 Abbeville Greenwood Aiken Hampton Allendale Horry Anderson Jasper Bamberg Kershaw Barnwell Lancaster Beaufort Laurens Berkeley Lee Calhoun Lexington Charleston Marion Cherokee Marlboro Chester McCormick Chesterfield Newberry Clarendon Oconee Colleton Orangeburg Darlington Pickens Dillon Richland Dorchester Saluda Edgefield Spartanburg Fairfield Sumter Florence Union Georgetown Williamsburg Greenville York The 2006 International Energy Conservation Code The 2006 IECC was adopted during the 2005 International Code Council (ICC) code cycle and is currently available to states for adoption. It is published by the International Code Council. For additional details or to obtain a copy of the 2006 IECC, contact the ICC by phone or visit their website at www.iccsafe.org. The IECC is the national model energy standard certified by the U.S. Department of Energy pursuant to the Energy Policy Act (EPAct). EPAct requires that all states review and consider adopting the IECC as the state building energy code. Table of IECC Requirements for Window Selection in South Carolina Simplified Prescriptive Paths for Compliance with the 2006 IECC for Windows in New Buildings and Remodeling & Replacement Windows Package Window & Door U-factor Skylight U-Factor Window, Door & Skylight SHGC Climate Zone 3 0.65 0.65 0.40 NOTES: 1. This table of window requirements is based upon the 2006 IECC and does not necessarily reflect the version of the IECC that may have been adopted by the state or any state-specific amendments. The IECC specifies additional requirements for other parts of the building envelope not listed here, such as insulation for walls and ceilings. 2. This table applies to residential build ings as defined in the IECC for compliance under the prescriptive approach. The 2006 IECC permits unlimited window area, so long as the prescriptive requirements are satisfied. In addition to new construction, this table of prescriptive requirements applies to all additions, alterations and replacement fenestration. 3. "Window" refers to glazed products in exterior walls of buildings, including glass doors and glass block, along with the accompanying sashes, frames, etc. Windows include all glazed products in the exterior of buildings that are not skylights. "Skylight" refers to glazed products installed at a slope of 15 degrees or more from vertical. 4. U-factor is a number, generally between 0.2 and 1.20, that indicates the rate of heat loss (or gain) through a window. A lower U-factor demonstrates a greater resistance to heat loss and gain, i.e., better insulating value of the window. As a result, a lower number produces greater winter comfort. 5. SHGC, or Solar Heat Gain Coefficien t, is a number between 0 and 1 that indicates the fraction of radiation (heat) from the sun that is transmitted through the window; the lower the SHGC, the less the amount of solar radiation that is allowed to pass through the window and become unwanted additional heat in the summer. As a result, a lower number produces greater summer comfort. 6. Window and skylight U-factor and SHGC values are maximum acceptable levels. An area-weighted average of fenestration products shall be permitted to satisfy the U-factor and SHGC requirements. Up to 15 square feet of glazed fenestration is permitted to be exempt from the U-factor and SHGC requirements. 7. Window U-factor and SHGC must be determined from a National Fenestration Rating Council (NFRC) label on the product or from a limited table of product default values in the IECC. 8. The code requires that non-site-built windows be labeled in a manner to show that they meet the IECC's air infiltration requirements; specifically, equal to or better than 0.30 cfm per square foot of window area (swinging doors below 0.50 cfm) as determined in accordance with NFRC 400, AAMA/WDMA 101/I.S.2, or AAMA/WDMA 101/I.S.2/NAFS. 9. The labeled product U-factor and SHGC should also be used in calculation procedures to properly size the home's HVAC equipment. The IECC requires the use of an appropriate computational procedure to size equipment. Properly sized equipment will operate more efficiently and effectively and will save money up front because builders and consumers can avoid paying extra for oversized equipment. 51 Look for the NFRC Label! The 2 most important values to look for are: U-factor & Solar Heat Gain Coefficient (SHGC) See the Efficient Windows Collaborative (EWC) web site for more information. www.efficientwindows.org Limitations This guide is an energy code compliance aid for window selection in South Carolina based upon the 2006 IECC and reflects the prescriptive values from Table 402.1.1 of that code. This guide only addresses window requirements and not the requirements applicable to the rest of the home. It does not provide a guarantee that a home meets the IECC, nor is it a guarantee that the home meets the energy code of the state. The guide has not been customized to reflect the version of the IECC or any state-specific amendments that South Carolina may adopt or has adopted. For additional details on South Carolina's energy code, please contact your local building guide official.

Source: City of Spartanburg website. First collected Oct 17, 2026.