RecordWell Data

Design Review Board — Agenda Packet

City of Spartanburg · Spartanburg County · Boards and Commissions · meeting of Dec 2, 2025 · Agenda packets

Open the original document More from City of Spartanburg

Text

Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.

City of Spartanburg | Design Review Board Agenda 1 AGENDA December 2, 2025, at 5:30 P.M. Dr. TK Gregg Community Center 650 Howard Street – Spartanburg, SC 29303 (Please Note: Items as they appear on the Docket may or may not be considered in the order as they are presented. The Chairperson will announce any changes after the roll call). I. Roll Call. II. Freedom of Information Act Compliance – Public notification of the Design Review Board meeting has been published, posted and mailed in compliance with the Freedom of Information Act and the requirements of the City of Spartanburg Zoning Ordinance. III. Rules and Procedures for Meeting Conduct. IV. Approval of Agenda. V. Disposition of the Minutes of October 7, 2025 meeting. VI. Old Business: VII. New Business: 1. DRB-25-020-00013 — The Design Review Board (DRB) has received a request for Preliminary Conceptual Approval for the proposed development, Spartanburg Hudson Automotive Parking, located at 400 E Daniel Morgan Ave (Tax Map Sheet: 7-12-06- 061.00) with a zoning designation of DT-5 (Downtown Urban Center). Owner: RP CGR SBG MAZ-SUB; Applicant: Hudson Automotive Group VIII. Staff Announcements: ACOG continued training education. IX. Adjournment. For more information, please contact the City of Spartanburg Planning Department at planning@cityofspartanburg.org or call (864) 596-2068. The City of Spartanburg Design Review Board DRB – Meeting Minutes – 2025-10-07 Page 1 of 4 Meeting Minutes of the Design Review Board (DRB) Tuesday, October 7, 2025, at 5:30 PM Dr. TK Gregg Recreation Center The Design Review Board (DRB) on Tuesday, October 7, 2025, at 5:30pm. The following Board Members were in attendance: Alexander Newman, Jean Crowther, and Lukas Hauser. Representing the City of Spartanburg’s Planning Department was Fredalyn Frasier, Planning Director, and Dominick Calace, Planner I. Mr. Newman: Alexander Newman Mr. Hauser: Lukas Hauser Ms. Crowther: Jean Crowther Ms. Crowther: With the Freedom of Information Act Compliance, public notification of the Design Review Board meeting has been published, posted and mailed in compliance with the Freedom of Information Act and the requirements of the City of Spartanburg Zoning Ordinance. Amend the Agenda: On a motion by Mr. Hauser to approve and seconded by Mr. Newman the case has been moved to the top of the agenda list by a vote of 3 to 0. Approval of Meeting Minutes for September 2, 2025. On a motion by Mr. Newman to approve and seconded by Mr. Hauser, the amended minutes were approved by a vote of 3 to 0. Old Business: None. New Business: DRB-25-020-00011 – The Design Review Board (DRB) has received a request for Preliminary Conceptual Approval for the proposed development, Spartanburg Mazda, located at 500 E Daniel Morgan Ave (Tax Map Sheet: 7-12-03-115.00) with a zoning designation of DT-5 (Downtown Urban Center). Owner: RP CGR SBG MAZ-SUB, LLC; Applicant: Hudson Automotive; Agent: Riyad Brothers GENERAL PROJECT OVERVIEW The existing Spartanburg Mazda is proposing a renovation of the building facade. The project also includes landscaping and streetscape improvements. The application is for Preliminary Review. AUTHORITY & APPLICABILITY This parcel is zoned D-T5. The proposed project is considered an exterior renovation without expansion in accordance with Section 2.2. The following elements are required to come into full compliance: Solid Waste Storage Areas and Signage Standards. Full streetscape and building design elements are also required for compliance. Formal design review and approval by the Design Review Board is required. A special exception is required in accordance with Section 3.1.3. DETERMINATION OF COMPLETENESS DRB – Meeting Minutes – 2025-10-07 Page 2 of 4 Application is complete. EXCEPTIONS REQUIRED • 6.4.5 Building Materials: To permit the use of metal paneling • 8.1.1 Streetscape: To provide a code minimum level of streetscape enhancement • 8.2.1 Required Plantings: To provide a code minimum level of parking area landscaping • 8.2.2 Parking Area Screening: To provide a code minimum level of parking area screening CODE REVIEW Deficiencies noted, or exceptions or deviations required, are noted in blue italics A. Use Standards: The proposed use (Vehicle Sales) requires a Special Exception and is subject to the additional standards in Section 3.2.11. • All renovations to the existing showroom shall not have to meet the maximum setbacks requirements or minimum height restrictions (Compliant). However, all physical lot expansions into any existing Vehicle Sales site shall require all such expansions on the new parcel only to come into full compliance (Not Applicable). B. District Standards: • 3.3.1 Lot Configuration: Not Applicable • 3.3.2 Primary Building Standards: – Compliant • 3.3.4.a Building Height: Not Applicable per Section 3.2.11 • 3.3.5 Permitted Parking Location: Existing non-conformity – No expansion requested • 3.3.6 Building Frontage: Shopfront/Awning (setback behind parking lot) -- Legal non- conformity C. General Standards: • Not Applicable D. Lot/Site Standards: • 5.1.1 Lot Frontage: All lots must front on a street, square, or common open space - Compliant • 5.1.3 Pedestrian Entries from Frontage Line: Buildings must have their principal pedestrian entrances on a frontage line. - Compliant • 5.1.4 Setbacks: Front and side setbacks must be consistent with surrounding buildings. - Compliant • 5.1.5 Adjacent Lots: Grading between lots to be sensitively considered. – Not Applicable E. Utilities and Trash Containment: • 5.2.1 Underground Utilities: Presumed Compliant • 5.2.2 Solid Waste Storage Areas: Full screening of all solid waste enclosures required - Compliant • 5.2.3 Mechanical and Utility Equipment: Presumed Compliant F. Building Standards: • 6.1.1 General Design Principles - Connectivity: Compliant DRB – Meeting Minutes – 2025-10-07 Page 3 of 4 • 6.1.2 General Design Principles - Housing: Not Applicable • 6.1.3 General Design Principles – Mixed-Use Infill & Redevelopment: Not Applicable • 6.1.4 General Design Principles - Downtown Should be Urban: Existing non- conformity – Not Applicable • 6.1.5 General Design Principles - Put People First: Compliant • 6.2 Required Building Design Standards: o 6.2.1 Architectural Style: Compliant o 6.2.2 Compatibility: Compliant o 6.2.3 Proportions: Compliant o 6.2.4 Wall Materials: Compliant o 6.2.5 Façade Treatment: Compliant o 6.2.6 Building Entrances: Compliant • 6.4 Specific Building Design Standards for all D-T5 Mixed-Use and Commercial Buildings o 6.4.1 Roof and Eaves: Compliant; Rooftop equipment screening to be confirmed with Final Approval o 6.4.2 Canopies/Awnings: Not Applicable o 6.4.3 Encroachments: Not Applicable o 6.4.4 Ground Level Detailing: Compliant o 6.4.5 Materials: Exception Required – The proposed project uses a metal paneling system similar to the adjacent car dealership. The stucco finish will match what is on the existing building. G. Parking: • 7.1 Parking Area Access: Existing front yard parking is a non-conformity • 7.2 Bicycle Parking: 4 spaces provided – Compliant • H. Streetscape and Site Landscaping: • 8.1 Required Streetscape: o D-T5: 12 ft zone with 8 ft wide sidewalk and trees in wells: Compliance Required • 8.2 Parking Area Landscaping: Compliance Required • 8.2.1 Required Plantings: o One (1) Shade Tree and Eight (8) Shrubs required per 10 parking spaces: Compliant o No parking space shall be further than 60 feet from the trunk of a canopy tree: Not Compliant – 42 parking spaces along E Daniel Morgan Ave outside required range • 8.2.2 Parking Area Screening: Not Compliant – landscape plan lists shrubs maintained at 2 feet high. Parking areas must have a 3-foot-high screen along the street. I. Signage: Freestanding Sign is non-compliant. Existing pole sign would need to be modified to not exceed 5 feet in height and 32 square feet in area ADDITIONAL COMMENTS AND SUGGESTIONS FOR BOARD CONSIDERATION Streetscape Requirements DRB – Meeting Minutes – 2025-10-07 Page 4 of 4 Required Plantings There are approximately 32 spaces across the frontage that are not covered by the minimum 60-foot radius from a canopy tree. The non-compliant parking spaces are outlined. RECOMMENDATION The following exceptions are required for Preliminary Approval: • 6.4.5 Building Materials: To permit the use of metal paneling • 8.1.1 Streetscape: To provide a code minimum level of streetscape enhancement • 8.2.1 Required Plantings: To provide a code minimum level of parking area landscaping • 8.2.2 Parking Area Screening: To provide a code minimum level of parking area screening Applicant: Riyad Brothers, Hudson Automotive. Public Comments: None. Discussion: The board appreciated the overall design, especially the landscape plan, and the effort to create a thoughtful corridor that supports downtown. They thanked staff for their comments and clarity. In the Spartanburg Mazda case, the board supported the use of warmer lighting and consistent materials across dealerships along Daniel Morgan Avenue. They noted the two-story display area, urban paneling, and overall architectural approach as strong. Final details like signage, fencing, and landscaping will be reviewed by staff as part of the conditional approval. A motion was made by Mr. Newman, seconded by Mr. Hauser, for full and final approval with exception for the use of ACM and staff conditions noted by motion with a vote of 3–0. Staff Announcements: Staff noted that the Subaru lot project will be advancing soon. They also shared that ACOG training is continuing. Adjourned meeting at 5:58 P.M. _________________________________ Jean Crowther, Vice Chair Planning Department Design Review Board Meeting 12.02.2025 Spartanburg Hudson Automotive Parking – 400 E Daniel Morgan Ave DRB Preliminary Review Planning Department Phone: (864) 596-2068 | email: planning@cityofspartanburg.org website: www.cityofspartanburg.org DATE November 24, 2025 PROJECT/ADDRESS/ TAX ID Spartanburg Hudson Automotive Parking / 400 E Daniel Morgan Ave / 7-12-06-061.00 TO Design Review Board Members PROJECT NUMBER DRB- 25-02000013 REVIEW STATUS – Preliminary Review COPIES TO City Departments/Applicant STAFF Fredalyn M. Frasier, Planning Director Dominick Calace, Planner I GENERAL PROJECT OVERVIEW The existing Spartanburg Subaru dealership is proposing the addition of an accessory structure to serve as an auto detailing area, along with an expanded 126-space parking lot. The project also includes new landscaping and streetscape enhancements. This application is for Preliminary Review. This project is part of a broader corridor beautification initiative between the City and the Hudson Automotive Group, which will provide enhanced landscape medians and landscaped bulb-outs along the parallel parking areas on Daniel Morgan Avenue. AUTHORITY & APPLICABILITY This parcel is zoned D-T5. The proposed project is considered a major parking expansion and a minor building expansion (less than 25% of total floor area) in accordance with Section 2.2. The accessory building associated with the expansion must comply with all applicable building design standards. Full streetscape and landscape improvements for the proposed parking lot are also required. Formal design review and approval by the Design Review Board is required. DETERMINATION OF COMPLETENESS Application is complete. EXCEPTIONS REQUIRED • 3.3.3.a Accessory Building Placement: To permit the placement of an accessory building in the side yard • 3.3.5 Permitted Parking Location: To permit front yard parking • 6.4.5 Building Materials: To permit the use of metal paneling • 8.1.1 Streetscape: To permit a 14 ft streetscape zone and 8 ft sidewalk without tree wells • 8.2.2 Parking Area Screening: To permit a shrub maintained at 2 ft high rather than 3 ft as required CODE REVIEW Deficiencies noted, or exceptions or deviations required, are noted in blue italics A. Use Standards: The primary use of this property is Vehicle Sales. Accessory Buildings are permitted in this zone. Planning Department Design Review Board Meeting 12.02.2025 Spartanburg Hudson Automotive Parking – 400 E Daniel Morgan Ave DRB Preliminary Review Planning Department Phone: (864) 596-2068 | email: planning@cityofspartanburg.org website: www.cityofspartanburg.org B. District Standards: • 3.3.1 Lot Configuration: Not Applicable • 3.3.2 Primary Building Standards: Not Applicable • 3.3.3a Accessory Building Placement: Exception Required – Accessory Building placed in side yard • 3.3.3b-e Accessory Building Setbacks: Compliant • 3.3.4.b Accessory Building Height: Compliant • 3.3.5 Permitted Parking Location: Exception Required – Front yard parking requested • 3.3.6 Building Frontage: Not Applicable C. General Standards: • Not Applicable D. Lot/Site Standards: • 5.1.1 Lot Frontage: All lots must front on a street, square, or common open space - Compliant • 5.1.3 Pedestrian Entries from Frontage Line: Not Applicable • 5.1.4 Setbacks: Not Applicable • 5.1.5 Adjacent Lots: Not Applicable E. Utilities and Trash Containment: • 5.2.1 Underground Utilities: Presumed Compliant • 5.2.2 Solid Waste Storage Areas: Not Applicable • 5.2.3 Mechanical and Utility Equipment: Presumed Compliant F. Building Standards: • 6.1.1 General Design Principles - Connectivity: Not Applicable • 6.1.2 General Design Principles - Housing: Not Applicable • 6.1.3 General Design Principles – Mixed-Use Infill & Redevelopment: Not Applicable • 6.1.4 General Design Principles - Downtown Should be Urban: Not Applicable • 6.1.5 General Design Principles - Put People First: Compliant • 6.2 Required Building Design Standards: o 6.2.1 Architectural Style: Compliant o 6.2.2 Compatibility: Compliant o 6.2.3 Proportions: Compliant o 6.2.4 Wall Materials: Compliant o 6.2.5 Façade Treatment: Compliant o 6.2.6 Building Entrances: Not Applicable • 6.4 Specific Building Design Standards for all D-T5 Mixed-Use and Commercial Buildings o 6.4.1 Roof and Eaves: Compliant; Rooftop equipment screening to be confirmed with Final Approval o 6.4.2 Canopies/Awnings: Not Applicable o 6.4.3 Encroachments: Not Applicable o 6.4.4 Ground Level Detailing: More detail requested – opacity of front facing windows should be in the range of 25-35% to allow sufficient passing of light and movement, but not full transparency into car wash/detail area. o 6.4.5 Materials: Exception Required – The proposed project uses a metal paneling system to match the adjacent car dealership. Planning Department Design Review Board Meeting 12.02.2025 Spartanburg Hudson Automotive Parking – 400 E Daniel Morgan Ave DRB Preliminary Review Planning Department Phone: (864) 596-2068 | email: planning@cityofspartanburg.org website: www.cityofspartanburg.org G. Parking: • 7.1 Parking Area Access: Front yard parking access is an existing non-conformity • 7.2 Bicycle Parking: Compliance Required H. Streetscape and Site Landscaping: • 8.1 Required Streetscape: o D-T5: 12 ft zone with 8 ft wide sidewalk and trees in wells: Exception Required – 8ft sidewalk with 14ft streetscape provided; trees are not included. This request is consistent with previously approved treatments for the adjacent Spartanburg Mazda and Spartanburg Subaru projects. • 8.2 Parking Area Landscaping: Compliant • 8.2.1 Required Plantings: o One (1) Shade Tree and Eight (8) Shrubs required per 10 parking spaces: Compliant o No parking space shall be further than 60 feet from the trunk of a canopy tree: Compliant • 8.2.2 Parking Area Screening: Exception Required – Shrubs maintained at 2 feet high. Parking areas must have a 3-foot-high screen along the street. This request is consistent with previously approved treatments for the adjacent Spartanburg Mazda and Spartanburg Subaru projects. Landscape screening is also required along the proposed detention pond. It has been added to be compliant. • 8.4 Fences: Compliant – 4 ft high black chain link fence around detention pond I. Signage: Not Applicable ADDITIONAL COMMENTS AND SUGGESTIONS FOR BOARD CONSIDERATION This project is part of a larger automotive corridor enhancement initiative. The proposed landscape and streetscape improvements are consistent with those of the adjacent approved projects, Spartanburg Mazda and Spartanburg Subaru. Exceptions to Streetscape Landscaping and Parking Area Screening were previously granted for these neighboring projects. RECOMMENDATION The following exceptions are required for Preliminary Approval: • 3.3.3.a Accessory Building Placement: To permit the placement of an accessory building in the side yard • 3.3.5 Permitted Parking Location: To permit front yard parking • 6.4.4 Ground Level Detailing: More detail requested on opacity of front-facing windows • 6.4.5 Building Materials: To permit the use of metal paneling • 8.1.1 Streetscape: To permit a 14 ft streetscape zone and 8 ft sidewalk without tree wells • 8.2.2 Parking Area Screening: To permit a shrub maintained at 2 ft high rather than 3 ft as required Spartanburg PDI DRB presentation©2025 All Rights Reserved. Context planSpartanburg PDI DRB presentation©2025 All Rights Reserved. Aerial site planSpartanburg PDI DRB presentation©2025 All Rights Reserved. Project site location Spartanburg PDI DRB presentation©2025 All Rights Reserved. Site Photos 1 Spartanburg PDI DRB presentation©2025 All Rights Reserved. Site Photos 2 Subaru of Spartanburg DRB presentation©2023 All Rights Reserved. Survey L/S L/SL/S L/S L/SL/S L/S L/S L/S L/S L/S L/S L/S L/S L/S L/S L/S L/S L/S L/S L/S CO CO CO CO CO COCO CO COCO N31° 29' 44"W 144.57' N3° 22' 15"W39.10' N58° 32' 07"E 1628.39' S62° 15' 43"W 74.17' S59° 03' 19"W 400.69' S57° 37' 25"W 94.91' S55° 34' 05"W 104.83' SAWCUT EW/S 106 CHDSSC DS CHDSSC DS CHDSSCDS DS DS RAL H1 H1 H1 H1H1 H1 H1 VAC VAC Space SaverDeluxe Cabinet310180 Space SaverDeluxe Cabinet310180 DS 12 THIS PLAN IS FOR COORDINATION OF SIDEWALK JOINTS, SCORES, AND FINISHES INREGARDS TO THE SITE WORK IMMEDIATELY ADJACENT TO THE BUILDING. DO NOTSCALE DRAWING TO DETERMINE DISTANCES, CURB CUTS, AND SLOPES. SEE CIVILPACKAGE FOR ALL SITE WORK. HANDICAP PARKING SPOT WITH ACCESS ISLE TO COMPLY WITH ADA SIZING ANDACCESS REQUIREMENTS. PROVIDE REQUIRED SIGNAGE AND CURB STOP.SEE CIVIL DOCUMENTS. FOR ALL EXTERIOR SIGNAGE: COORDINATION REQUIRED WITH VENDOR ANDARCHITECT PRIOR TO FABRICATION. ELECTRIC VEHICLE (EV) PARKING SPOT AND CHARGER, PROVIDE DUAL PEDESTALCHARGING STATION AND POWER AS REQUIRED - SEE ELECTRICAL DWG.EV PLANTER, SEE CIVIL DOCUMENTS.BROOM FINISH CONCRETE WITH SCORE JOINTS, SEE CIVIL DOCUMENTS.ASPHALT PAVING, SEE CIVIL DOCUMENTS. COORDINATE ALL REQUIRED ROLL CURBS TO PROVIDE VEHICLE ACCESS TO VEHICLEENTRY DOUBLE DOORS AS DESIGNATED ON PLANS. SEE CIVIL DOCUMENTS FOR FURTHERCLARIFICATION. GENERAL NOTES123 SITE FINISH LEGEND: EXISTING SIGNAGE TO REMAIN4 Site planSpartanburg PDI DRB presentation©2025 All Rights Reserved. Subaru of Spartanburg DRB presentation©2023 All Rights Reserved. Overall paving plan Subaru of Spartanburg DRB presentation©2023 All Rights Reserved. Paving plan Subaru of Spartanburg DRB presentation©2023 All Rights Reserved. Grading plan Subaru of Spartanburg DRB presentation©2023 All Rights Reserved. Landscape plan Subaru of Spartanburg DRB presentation©2023 All Rights Reserved. Site Lighting plan Spartanburg PDI DRB presentation©2025 All Rights Reserved. Exterior Elevations 105D 104B 103C 103D 103E 103F WD EW/S 1234 105C 103B 101100 102 104C 105B 105A 107A FUTURESTORAGE 104A PHOTO/DETAIL104 DETAIL BAYS103 ADMINOFFICE100 MEN101 WOMEN102 WASH BAYS105 EQUIPMENT107 COMPRESSOR106 103A 1/A8.0 106 DS DS DS DS SF2 H1 H1 H1 H1 H1 H1 H1 VACVAC Space SaverDeluxe Cabinet310180 Space SaverDeluxe Cabinet310180 DS 12 103G 105E Spartanburg PDI DRB presentation©2025 All Rights Reserved. First floor plan CHDSSC CHDSSC CHDSSCDS SLOPE SLOPE RALSLOPE SLOPE SLOPE SLOPE Spartanburg PDI DRB presentation©2025 All Rights Reserved. Roof plan 1069'-0"9'-0" OTS 9'-0" OTS OTS OTS OTS Spartanburg PDI DRB presentation©2025 All Rights Reserved. Reflected Ceiling plan Spartanburg PDI DRB presentation©2025 All Rights Reserved. Lighting Schedule 3WALL SECTIONSCALE: 3/4" = 1'-0" FLOOR LINE DETAIL BAYS103 ROOF MEMBRANE EXTENDS UPPARAPET AND UNDER COPINGPREFINISHED ALUMINUM COPINGOVER TREATED 2X BLOCKINGSLOPE HEAVY DUTY HIGH LIFT OVERHEADDOOR AND TRACK. SEE FLOORPLAN AND DOOR SCHEDULE. CONCRETE SLAB ANDFOUNDATION. SEE STRUCTURALFOR STEEL ANGLE EDGECONDITION AT OHD'S.EXTERIOR CONCRETESLAB SEE CIVILDRAWINGS. PERIMETER FOUNDATIONINSULATION TYPICAL ATEXTERIOR WALLS 2'-0" MIN. TYP. 6"1/2" SEE STRUCTURAL FORLINTEL REQUIREMENTS 1WALL SECTIONSCALE: 3/4" = 1'-0" PREFINISHED ALUM. GUTTERAND DOWNSPOUTS. SEEROOF PLAN. 2'-0" MIN. TYP. PERIMETER FOUNDATIONINSULATION TYPICAL ATEXTERIOR WALLS 0'-0" AFFFLOOR LINE STEEL PLATE DS PROTECTORSEE DETAIL 1/A8.0 EQUIPMENTSTORAGE107 @ 20'-0" AFFTOP OF MASONRYROOF MEMBRANE EXTENDS UPPARAPET AND UNDER COPING PREFINISHED ALUMINUM COPINGOVER TREATED 2X BLOCKINGSLOPE ROOFING SYSTEM TERMINATIONSTRIP AND SEALANT DAM PERMFG. REQUIREMENTS. THROUGH WALL SCUPPER SEEDETAIL 4/A8.0. SEE DETAIL 3/A8.0FOR OVERFLOW SCUPPER DETAIL.PREFINISHED ALUM.COLLECTOR BOX ANDDOWNSPOUT. SEE EXT. ELEV. 2WALL SECTIONSCALE: 3/4" = 1'-0" EQUIPMENTSTORAGE107WASH BAYS105 2'-0" MIN. TYP.0'-0" AFFFLOOR LINE PERIMETER FOUNDATIONINSULATION TYPICAL ATEXTERIOR WALLS DETAIL BAYS103 @ 20'-0" AFFTOP OF MASONRYROOF MEMBRANE EXTENDS UPPARAPET AND UNDER COPING PREFINISHED ALUMINUM COPINGOVER TREATED 2X BLOCKINGSLOPE @ 12'-8" AFFTOP OF MASONRY 4WALL SECTIONSCALE: 3/4" = 1'-0" EXTERIOR CONCRETE SLABSEE CIVIL DRAWINGS. 0'-0" AFF FULLY ADHERED TPO ROOFSYSTEM OVER MINIMUM 4"POLYISO RIGID INSULATION.60 MIL WHITE MEMBRANETYPICAL.CONCRETE SPLASH BLOCKAT ROOFTOP DS LOCATIONS. FULLY ADHERED TPO ROOFSYSTEM OVER MINIMUM 4"POLYISO RIGID INSULATION.60 MIL WHITE MEMBRANETYPICAL. FULLY ADHERED TPO ROOFSYSTEM OVER MINIMUM 4"POLYISO RIGID INSULATION. 60MIL WHITE MEMBRANE TYPICAL. STEEL BEAMS AND 3" METALDECK. SEE STRUCTURAL.STEEL BEAMS AND 3" METALDECK. SEE STRUCTURAL. STEEL BEAMS AND 3" METALDECK. SEE STRUCTURAL. STEEL BEAMS AND 1 1/2" METALDECK. SEE STRUCTURAL. SPLIT FACE AND SMOOTHCONCRETE BLOCK. SEE EXTERIORELEVATIONS. SEE STRUCTURALFOR ANY REINFORCING ANDGROUTING REQUIRED.SPLIT FACE AND SMOOTHCONCRETE BLOCK. SEE EXTERIORELEVATIONS. SEE STRUCTURALFOR ANY REINFORCING ANDGROUTING REQUIRED.SPLIT FACE AND SMOOTHCONCRETE BLOCK. SEE EXTERIORELEVATIONS. SEE STRUCTURALFOR ANY REINFORCING ANDGROUTING REQUIRED. 12'-0" 1'-4"SMOOTH6'-0" 8"SMOOTH20'-0" 12'-0" 1'-4"SMOOTH6'-0" 8"SMOOTH20'-0" SMOOTH FACE CMU INDICATEDSHADED. Spartanburg PDI DRB presentation©2025 All Rights Reserved. Wall Sections Rendering 1Spartanburg PDI DRB presentation©2025 All Rights Reserved. Rendering 2Spartanburg PDI DRB presentation©2025 All Rights Reserved. Rendering 3Spartanburg PDI DRB presentation©2025 All Rights Reserved.

Source: City of Spartanburg website. First collected Oct 17, 2026.