RecordWell Data

Design Review Board Meeting — Agenda Packet

Town of Hilton Head Island · Beaufort County · Design Review Board · meeting of Mar 25, 2026 · Agenda packets

Open the original document More from Town of Hilton Head Island

Text

Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.

Town of Hilton Head Island Design Review Board Meeting Wednesday, March 25, 2026, 2:30 PM 1 Town Center Court, Hilton Head Island, SC Benjamin M. Racusin Council Chambers The Design Review Board meeting will be held in person at Town Hall in the Benjamin M. Racusin Council Chambers. 1. Call to Order 2. Adoption of the Agenda 3. Approval of the Minutes a. Regular Meeting Minutes of March 11, 2026 4. Unfinished Business 5. New Business a. DRB-000266-2026 - 1 North Forest Beach Unit A1 - Alteration 6. Public Comment - Non Agenda Items 7. Board Business 8. Staff Reports 9. Adjournment FOIA Compliance: Public notification of this meeting has been published, posted, and distributed in compliance with the South Carolina Freedom of Information Act and the requirements of the Town of Hilton Head Island. In accordance with the requirements of Title II of the Americans with Disabilities Act of 1990 ("ADA"), the Town of Hilton Head Island will not discriminate against qualified individuals with disabilities on the basis of disability in its services, programs, or activities. Auditory accommodations are available. Any person requiring further accommodation should contact the Town of Hilton Head Island ADA Coordinator as soon as possible but no later than 48 hours before the scheduled event. Page 1 of 22 Municipal Association of South Carolina (MASC) Civility Pledge: “I pledge to build a stronger and more prosperous community by advocating for civil engagement, respecting others and their viewpoints, and finding solutions for the betterment of my city or town.” Page 2 of 22 Town of Hilton Head Island Design Review Board Meeting Minutes 3/11/2026 Page | 1 Town of Hilton Head Island DESIGN REVIEW BOARD MEETING Wednesday, March 11, 2026, 2:30 PM Minutes 1. Call to Order Chair Carstens called the meeting to order at 2:30 p.m. In attendance: Judd Carstens, Annette Lippert, Megan Fitzpatrick, Todd Theodore, Tom Parker, and Patricia Pastor 2. Adoption of the Agenda Mr. Parker made a motion to adopt the agenda. Ms. Pastor seconded. The motion passed unanimously. 3. Approval of the Minutes a. Regular Meeting Minutes of February 25, 2026 Ms. Fitzpatrick made a motion to approve the minutes of February 25, 2026. Mr. Theodore seconded. The motion passed unanimously. 4. Unfinished Business a. DRB-000212-2026 - 840 William Hilton Parkway - The Atrium Building - Final Chair Carstens and Mr. Tom Parker both recused themselves. Principle Planner Melissa Paul-Leto presented The Atrium Building for final review. The applicant answered questions from the board. Ms. Fitzpatrick made a motion to approve with the following conditions: outdoor areas associated with the upper level spaces, such as the balcony, shall not be utilized for commercial recreation purposes. The applicant will need to provide a building section illustrating the relevant upper-level outdoor areas and a plan notation clearly identifying these outdoor areas and their intended use for verification. Mr. Theodore seconded. The motion passed unanimously. 5. New Business a. DRB-000215-2026 - 862 William Hilton Parkway - Alteration Chair Carstens remained recused and Mr. Tom Parker returned to the Dais. Melissa Paul-Leto presented 862 William Hilton Parkway to the board for alterations. The applicant answered questions from the board. Mr. Parker made a motion to approve with the following conditions: improve integral lights in the lockers to meet guidelines standards once submitted and confirm that the parking count is not affected by taking out three spaces. Ms. Pastor seconded. The motion passed 4:1. Page 3 of 22 Town of Hilton Head Island Design Review Board Meeting Minutes 3/11/2026 Page | 2 6. Public Comment - Non Agenda Items Chair Carstens returned to the dais. Martin Lesch made a public comment regarding board ethics. 7. Board Business a. Discussion of proposed updates to the existing Design Guide and direction on advancing the updated Design Guide. Melissa Paul-Leto presented the Board's remaining comments regarding multiple elements of the Design Guide. Board members discussed their concerns and provided additional clarification and elaboration on their feedback. A draft of the Design Guide will be presented at the March 25, 2026, meeting. 8. Staff Reports 9. Adjournment The meeting adjourned at 4:36 p.m. Page 4 of 22 Page 5 of 22 Last Revised 01/21/15 1 Applicant/Agent Name: ______________________________ Company: _____________________________________ Mailing Address: ___________________________________ City: _________________ State: ______ Zip: ________ Telephone: ___________________ Fax: _________________ E-mail: _______________________________________ Project Name: _________________________________ Project Address: _____________________________________ Parcel Number [PIN]: R__ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ Zoning District: _______________________________ Overlay District(s): ___________________________________ Town of Hilton Head Island Community Development Department One Town Center Court Hilton Head Island, SC 29928 Phone: 843-341-4757 Fax: 843-842-8908 www.hiltonheadislandsc.gov CORRIDOR REVIEW, MAJOR DESIGN REVIEW BOARD (DRB) SUBMITTAL REQUIREMENTS Digital Submissions may be accepted via e-mail by calling 843-341-4757. Project Category: _____ Concept Approval – Proposed Development _____ Alteration/Addition _____ Final Approval – Proposed Development _____ Sign FOR OFFICIAL USE ONLY Date Received: _____________ Accepted by: ______________ DRB #:___________________ Meeting Date: _____________ Submittal Requirements for All projects: _____ Private Architectural Review Board (ARB) Notice of Action (if applicable): When a project is within the jurisdiction of an ARB, the applicant shall submit such ARB’s written notice of action per LMO Section 16- 2-103.I.4.b.iii.01. Submitting an application to the ARB to meet this requirement is the responsibility of the applicant. _____ Filing Fee: Concept Approval-Proposed Development $175, Final Approval – Proposed Development $175, Alterations/Additions $100, Signs $25; cash or check made payable to the Town of Hilton Head Island. Additional Submittal Requirements: Concept Approval – Proposed Development _____ A survey (1"=30' minimum scale) of property lines, existing topography and the location of trees meeting the tree protection regulations of Sec. 16-6-104.C.2, and if applicable, location of bordering streets, marshes and beaches. _____ A site analysis study to include specimen trees, access, significant topography, wetlands, buffers, setbacks, views, orientation and other site features that may influence design. _____ A draft written narrative describing the design intent of the project, its goals and objectives and how it reflects the site analysis results. _____ Context photographs of neighboring uses and architectural styles. _____ Conceptual site plan (to scale) showing proposed location of new structures, parking areas and landscaping. _____ Conceptual sketches of primary exterior elevations showing architectural character of the proposed development, materials, colors, shadow lines and landscaping. SWEET AL'S CANOPY REPLACEMENT JACOB WOODS P.O. BOX 3978 843-815-2557 843-815-2547 COURT ATKINS GROUP BLUFFTON SC 29910 JACOB.WOODS@COURTATKINS. COM 1 NORTH FOREST BEACH DRIVE UNIT 1A 552 018 000 0009 0000 CR- COLIGNY RESORT CORRIDOR OVERLAY DISTRICT CR X Page 6 of 22 Last Revised 01/21/15 2 N ote: All application items must be received by the deadline date in order to be reviewed by the DRB per LMO Appendix D: D-23. A representative for each agenda item is strongly encouraged to attend the meeting. Are there recorded private covenants and/or restrictions that are contrary to, conflict with, or prohibit the proposed request? If yes, a copy of the private covenants and/or restrictions must be submitted with this application. YES NO T o the best of my knowledge, the information on this application and all additional documentation is true, factual, and complete. I hereby agree to abide by all conditions of any approvals granted by the Town of Hilton Head Island. I understand that such conditions shall apply to the subject property only and are a right or obligation transferable by sale. I f urther understand that in the event of a State of Emergency due to a D isaster, the review and approval times set forth in the Land Management Ordinance may be suspended. SIGNATURE DATE Additional Submittal Requirements: Final Approval – Proposed Development _____ A final written narrative describing how the project conforms with the conceptual approval and design review guidelines of Sec. 16-3-106.F.3. _____ Final site development plan meeting the requirements of Appendix D: D-6.F. _____ Final site lighting and landscaping plans meeting the requirements of Appendix D: D-6.H and D-6.I. _____ Final floor plans and elevation drawings (1/8"=1'-0" minimum scale) showing exterior building materials and colors with architectural sections and details to adequately describe the project. _____ A color board (11"x17" maximum) containing actual color samples of all exterior finishes, keyed to the elevations, and indicating the manufacturer's name and color designation. _____ Any additional information requested by the Design Review Board at the time of concept approval, such as scale model or color renderings, that the Board finds necessary in order to act on a final application. Additional Submittal Requirements: Alterations/Additions _____ All of the materials required for final approval of proposed development as listed above, plus the following additional materials. _____ A survey (1"=30' minimum scale) of property lines, existing topography and the location of trees meeting the tree protection regulations of Sec. 16-6-104.C.2, and if applicable, location of bordering streets, marshes and beaches. _____ Photographs of existing structure. Additional Submittal Requirements: Signs _____ Accurate color rendering of sign showing dimensions , type of lettering, materials and actual color samples. For freestanding signs: _____ Site plan (1”=30’ minimum scale) showing location of sign in relation to buildings, parking, existing signs, and property lines. _____ Proposed landscaping plan. For wall signs: _____ Photograph or drawing of the building depicting the proposed location of the sign. _____ Location, fixture type, and wattage of any proposed lighting. Page 7 of 22 Page 8 of 22 March 10, 2026 Town of Hilton Head Island Melissa Paul-Leto, Principal Planner of Design 1 Town Center Court Hilton Head Island, South Carolina 29928 melissapl@hiltonheadislandsc.gov Re: Major Corridor Submittal for Sweet Al’s Canopy Modification (1 North Forest Beach Unit A1 ) Melissa, Please see the attached submittal for the modifications to the canopy at Sweet Al’s, including the following: - Design Review Application - Architectural Drawings - Site Plan - Color Board - Photographs of Existing Structure The new +/- 350 SF canopy will replace the existing fabric canopy over the outdoor seating area at Sweet Al’s. The framing will be PT wood with posts, columns and open rafters, matching the details around Coligny Plaza. The roof will be standing seam, to match the existing green standing seam around the development. Per Sec. 16-3-106.F.3., this structure will be an aesthetic upgrade over the existing deteriorating canopy and will tie harmoniously into the architecture of the Coligny Plaza development. If you have any questions or need any additional information, please let me know. Court Atkins Architects, Inc. Jacob Woods, Project Leader COURT ATKINS GROUP 32 BRUIN ROAD, BLUFFTON, SC29910 +1843 815 2557 T RESIDENTIAL I COMMERCIAL I INTERIORS n0C22 ?v .577 zD Page 9 of 22 PHOTOGRAPHS OF EXISTING STRUCTURE ua- 0a­LuI bz l<ua­LuI --0u l<{ ezuI ouLuI a- pLf"I Lu (Lu 0O M tO 7 o OO(4 uu z0-•LL ::,_J co 0<1 0or- z::,r­co (M a::> 0a0uz:,,: b<4 ba::> 0u COURT ATKINSGROUP Page 10 of 22 Page 11 of 22 GENERAL NOTES: A. NOTE TO GENERAL CONTRACTORS: THESE DRAWINGS HAVE BEEN PRODUCED UNDER A LIMITED SERVICES AGREEMENT BETWEEN THE OWNER/OWNER'S REPRESENTATION AND COURT ATKINS ARCHITECTS, INC. THEY ARE TO BE USED FOR DESIGN INTENT AND IN COORDINATION WITH SUPPLEMENT ENGINEERING DOCUMENTS. B. THE ARCHITECT'S DRAWINGS CANNOT STAND ALONE AS CONSTRUCTION DOCUMENTS. C. SEE STRUCTURAL ENGINEERING DOCUMENTS FOR STRUCTURAL CONNECTION TECHNIQUES, CALCULATIONS REQUIRED BY CODE, CODE COMPLIANCE INSTRUCTIONS FOR WALL AND ROOF CONSTRUCTION, AND TIE DOWN REQUIREMENTS. D. SEPARATE MECHANICAL, ELECTRICAL, AND PLUMBING ENGINEERING DOCUMENTS MAY BE PROVIDED, WHICH INDICATE REQUIRED SERVICE AND RISER DIAGRAMS, CALCULATIONS AND INSTALLATION SPECIFICATIONS BEYOND THE ARCHITECT'S BASIC LAYOUT AND SELECTIONS SUGGESTIONS. E. SEPARATE CIVIL ENGINEERING DOCUMENTS MAY BE PROVIDED, WHICH INDICATE ADDITIONAL SITE PLANNING, DRAINAGE, AND OTHER RELATED SITE WORK REQUIREMENTS. F. SELECTIONS NOT INCLUDED IN THESE DOCUMENTS WILL BE COORDINATED BY THE OWNER / OWNER'S REPRESENTATIVES. G. BY APPLYING FOR A BUILDING PERMIT AND/OR CONSTRUCTING THE PROJECT REPRESENTED HEREIN, THE OWNER AGREES TO LIMIT THE LIABILITY OF THE ARCHITECT TO THE OWNER OF THE PROJECT FOR ALL AND ANY CLAIMS, LOSSES, DAMAGES OR ANY NATURE WHATSOEVER, OR CLAIMS OF EXPENSES FOR ANY SUCH ITEMS TO THE ARCHITECT'S TOTAL COMPENSATION FOR SERVICES RENDERED HEREIN. H. THESE DOCUMENTS ARE THE WORK INSTRUMENTS OF THE ARCHITECT AND HAVE BEEN PREPARED SPECIFICALLY AND SOLELY FOR THE PROJECT NAMED HEREIN. THEY ARE NOT SUITABLE FOR USE ON OTHER PROJECTS OR IN OTHER LOCATIONS WITHOUT THE PARTICIPATION OF THE ARCHITECT. REPRODUCTION IS STRICTLY PROHIBITED. THE ARCHITECT SHALL BE DEEMED THE AUTHOR AND OWNER OF THESE DOCUMENTS AND SHALL RETAIN COMMON LAW, STATUTORY AND OTHER RESERVED RIGHTS, INCLUDING THE COPYRIGHT. I. THE ARCHITECT HAS NOT BEEN CONTRACTED TO PERFORM CONSTRUCTION ADMINISTRATION/ ON-SITE OBSERVATION FOR THIS PROJECT. J. FOR DIMENSIONS NOT SHOWN OR IN QUESTION, THE CONTRACTOR WILL REQUEST CLARIFICATION FROM THE ARCHITECT BEFORE PROCEEDING. K. CONTRACTOR WILL VERIFY ALL EXISTING CONDITIONS IN THE FIELD. ANY DISCREPANCIES WILL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT. L. THE CONTRACTOR SHALL MAINTAIN AT THE SITE OF THE WORK, A SET OF RECORD DRAWINGS. THE CONTRACTOR SHALL RECORD ALL CHANGES AND DEVIATIONS FROM THE DRAWINGS ON THIS "AS-BUILT" SET, WHICH SHALL BE UPDATED AT LEAST EVERY OTHER WEEK. AT THE CLOSE OF THE JOB, THE CONTRACTOR SHALL PROVIDE ONE COMPLETE SET OF ALL AS-BUILT INFORMATION TO THE ARCHITECT IN CLEAR AND LEGIBLE FORMAT. M. SIGNS SHALL BE LIMITED TO THE PROJECT IDENTIFICATION SIGN. THE IDENTIFICATION SIGN SHALL IDENTIFY THE PROJECT, THE ARCHITECT AND THE CONTRACTOR. N. INFORMATION CONTAINED ON THESE DRAWINGS IS PROVIDED FOR THE CONVENIENCE OF THE GENERAL CONTRACTOR IN EXECUTING THE WORK. EVERY ATTEMPT HAS BEEN MADE TO PROVIDE COMPLETE AND ACCURATE REPRESENTATIONS OF SUCH CONDITIONS. O. WHEN ARCHITECTURAL DRAWINGS ARE IN CONFLICT WITH ENGINEERING DRAWINGS THE GENERAL CONTRACTOR SHALL REQUEST CLARIFICATION FROM THE ARCHITECT BEFORE PROCEEDING. PROJECT TEAM: ARCHITECT COURT ATKINS ARCHITECTS, INC. 32 BRUIN ROAD P.O. BOX 3978 BLUFFTON, SC 29910 (843) 815-2557 PH (843) 815-2547 FAX GENERAL CONTRACTOR TBD LANDSCAPE ARCHITECT N/A CIVIL ENGINEER N/A OWNER CONTACT THE RICHARDSON GROUP, LLC P.O. BOX 6133 HILTON HEAD ISLAND, SC 29938 CONTACT: MR. COLLINS RICHARDSON (843) 686-6929 CRICHARDSON@RICHARDSONGRP.COM STRUCTURAL ENGINEER SHEARLOCK ENGINEERING, LLC 110 TRADERS CROSS, SUITE 232 OKATIE, SC 29909 (843) 473-8767 PH MECHANICAL, PLUMBING & FIRE PROTECTION N/A ELECTRICAL ENGINEER N/A INTERIOR DESIGNER N/A PROJECT INFORMATION: NAME OF PROJECT: SWEET AL'S CAFE PAVILION ADDRESS: 1 NORTH BEACH DRIVE UNIT 1A HILTON HEAD ISLAND, SOUTH CAROLINA 29928 PROPOSED USE: ASSEMBLY (A-2) OWNER CONTACT: THE RICHARDSON GROUP, LLC CODE ENFORCEMENT JURISDICTION: HILTON HEAD ISLAND INTERNATIONAL BUILDING CODE (IBC): 2021 INTERNATIONAL MECHANICAL CODE: 2021 INTERNATIONAL PLUMBING CODE: 2021 THE NATIONAL ELECTRICAL CODE: 2020 INTERNATIONAL FUEL GAS CODE: 2021 INTERNATIONAL FIRE CODE: 2021 INTERNATIONAL ENERGY CONSERVATION CODE: 2009 ICC/ANSI A117.1: 2017 DESIGNER OF RECORD: DESIGNER NAME LICENSE NO. TELEPHONE NO. ARCHITECTURAL JAMES C. ATKINS SC #6743 (843) 815-2557 ELECTRICAL N/A XX #XXXX (###) ###-#### PLUMBING/FIRE PROTECTION N/A XX #XXXX (###) ###-#### MECHANICAL N/A XX #XXXX (###) ###-#### STRUCTURAL JAKE EAVENSON SC #33500 (843) 473-8767 CIVIL N/A XX #XXXX (###) ###-#### LAND PLANNING/ N/A XX #XXXX (###) ###-#### LANDSCAPE VICINITY MAP - N.T.S. SITE POPE AVE N FOREST BEACH DRIVE AVOCET RD PROJECT DESCRIPTION: THE REPLACEMENT OF AN EXISTING CANOPY OVER THE OUTDOOR DINING DECK FOR SWEET AL'S CONSTRUCTION: WOOD CONSTRUCTION WITH EMBEDDED 6X6 PT POSTS, PT BEAMS AND PT OPEN RAFTERS WITH T&G WD SUBSTRATE AND STANDING SEAM METAL ROOFING GROSS BUILDING AREA: OVERALL AREA (OUTSIDE OF EXTERIOR WALL): 344 SQ. FT. BUILDING CODE SUMMARY ALLOWABLE HEIGHT, STORIES & AREA (PER IBC TABLE 504.3, 504.4 & 506.2): ASSEMBLY (A -2) ALLOWABLE ACTUAL HEIGHT: 40 FEET ±14'-4" S TORIES: 1 STORIES 1 STORIES A REA: 6,000 SQ. FT. 344 SQ. FT . A REA INCREASE? Yes _______ No _______ HEIGHT INCREASE? Yes _______ No _______ OCCUPANT LOAD (IBC TABLE 1004.5): OCCUPANCY (A -2) NO CHANGE TO OCCUPANT LOAD -- STRUCTURE IS TO REPLACE EXISTING CANOPY / NO CHANGE TO AREA EXITS (IBC TABLE 1006.3.3): REQUIRED PROVIDED NUMBER OF EXITS: 2 N/A (OPEN AIR) TRAVEL DISTANCE: EXIT ACCESS DESIGN REQUIREMENTS MAX. ALLOWABLE ACTUAL MAX. EXIT ACCESS TRAVEL DISTANCE (IBC TABLE 1017.2): 200 FT. 19 FT. C OMMON PATH OF TRAVEL (IBC TABLE 1006.2.1): 75 FT. N/A D EAD END CORRIDOR (IBC 1020.5): 20 FT. N/A PLUMBING CALCULATIONS NO CHANGE TO EXISTING PLUMBING FIXTURES OR OCCUPANCY COUNT PUBLIC RESTROOMS ARE PROVIDED WITHIN THE DEVELOPMENT OCCUPANCY CLASSIFICATION: MIXED OCCUPANCY: Yes _______ No _______ Separation _______ Hr. CONSTRUCTION TYPE: I-A I-B II-A II-B III-A III-B IV V-A V-B MIXED CONSTRUCTION: Yes _______ No _______ Type ________________ SPRINKLERED: Yes _______ No _______ FIRE DISTRICT: Yes _______ No _______ BUILDING HEIGHT (MRH): Number of Stories: _______ MEZZANINE: Yes _______ No _______ HIGH RISE: Yes _______ No _______ X X X X X X 14' - 4" 1 N/A ASSEMBLY (A-2) BUILDING DATA POST OFFICE BOX 3978 BLUFFTON, SC 29910 PH: 843.815.2557 FX: 843.815.2547 WWW.COURTATKINS.COM ISSUE PROJECT INFO SHEET TITLE Date Project No. COPYRIGHT 2024 COURT ATKINS GROUP - THIS DRAWING IS THE PROPERTY OF THE ARCHITECT AND IS NOT TO BE REPRODUCED IN WHOLE OR IN PART BY ANY MEANS OR METHOD WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ARCHITECT. ANY UNAUTHORIZED REPRODUCTION OR REUSE OF THESE DOCUMENTS WILL RESULT IN LEGAL ACTION. NOT FOR C ONSTRU CTION NOT FOR C ONSTRU CTION © 5/30/2025 12:09:41 PM PERMIT DRAWINGS SWEET AL'S CAFE PAVILION RENOVATION 1 NORTH BEACH DRIVE UNIT 1A HILTON HEAD ISLAND, SOUTH CAROLINA 29928 05.30.2025 25-021 COVER, GENERAL NOTES AND CODE SUMMARY A0.0 SWEET AL'S CAFE PAVILION RENOVATION 1 NORTH BEACH DRIVE UNIT 1A HILTON HEAD ISLAND, SOUTH CAROLINA 29928 SHT. # SHEET NAME PERMIT DRAWINGS 05.30.2025 A0.0 COVER, GENERAL NOTES AND CODE SUMMARY X A2.0 FLOOR PLAN, ELEVATIONS, SECTIONS AND DETAILS X S1.0 STRUCTURAL NOTES X S2.0 STRUCTURAL PLANS & DETAILS X SHEET INDEX: NO. REV. DATE DESCRIPTION L L > grCOURT ATKINSGROUP Page 12 of 22 ALTA/NSPS LAND TITLE SURVEY Page 13 of 22 A. G.C. / SUB-CONTRACTORS SHALL BE RESPONSIBLE FOR ALL MEANS AND METHODS OF COMPLETING THE SCOPE OF WORK. B. SEE COVER PAGE FOR NOTES AND LIMITATIONS TO ARCHITECTURAL SCOPE OF SERVICES. C. SEE A0.2 FOR ANSI/ADA REQUIREMENTS. D. GC/OWNER TO COORDINATE ALL IN-SLAB ELECTRICAL AND PLUMBING REQUIREMENTS WITH APPROPRIATE SUBCONTRACTOR TRADES PRIOR TO PLACING SLAB. E. ADJUST TOP OF SLAB, WALL, AND ROOF BEARING PLATES AS REQUIRED FO R C HANGES IN STRUCTURAL MEMBER SIZES OR EXISTING SITE CONDITIONS. F. STRUCTURAL ENGINEERING DOCUMENTS SUPERSEDE ARCHITECTURAL DOCUMENTS AND SCHEDULES WITH REGARD TO SIZE OF STRUCTURAL MEMBERS, PLACEMENT, AND CONNECTION DETAILS. G. DIMENSIONS ARE TO THE EDGE OF FOUNDATION AND FRAMING, U.N.O. DO NOT SCALE DRAWINGS. CONTACT ARCHITECT WITH ANY DISCREPANCIES. H. GC TO FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO DEMOLITION AND NOTIFY ARCHITECT OF ANY DISCREPANCIES OR UNKNOWN CONDITIONS. GENERAL FLOOR PLAN NOTES: A2.0 3 6 A2.0 A2.05A2.0 4 7' - 4 1/4" 6' - 10" 14' - 8 1/2" 6' - 11" V.I.F. 14' - 2 1/4" V.I.F. 21' - 7 1/2" 7 A2.0 MAX TRAVEL DISTANCE = 19' EXISTING DECK TO REMAIN MATCH EXISTING RAILING NO CHANGE TO EXIST. STRUCT. NOTE: GC TO PROTECT EXISTING STRUCTURE, FINISHES & SYSTEMS DURING DEMOLITION OF EXISTING CANOPY AND CONSTRUCTION. EXISTING LIGHT FIXTURES, FANS & OTHER ASSOCIATED COMPONENTS SHALL BE REMOVED AND STORED TO BE REINSTALLED. WOOD DECK 0' - 0" AFF RIDGE HT. 14' - 4" AFF ROOF BEARING (V.I.F.) 7' - 6" AFF 4" 12" (MIN. 6'-8" V.I.F.) 6' - 8 3/4" 10" 12" 10" 12" 6X6 PT COLUMN, SEE STRUCT. PT RAILING, TO MATCH EXIST. 2X8 PT WD RAFTERS, SEE STRUCT. MTL. FLASHING 10' - 0" 7 A2.0 2X8 PT COLLAR TIE, SEE STRUCT. 3X10 PT BEAM, SEE STRUCT. EXIST. SIGN TO BE PRESERVED AND REUSED UPPER BEARING 9' - 10" AFF 3'-0" (V.I.F.) WOOD DECK 0' - 0" AFF RIDGE HT. 14' - 4" AFF 6 A2.0 ROOF BEARING (V.I.F.) 7' - 6" AFF 22 GA. STANDING SEAM MTL. RF. PT RAILING, TO MATCH EXIST 2X8 PT WD RAFTERS, SEE STRUCT. EXIST. RF. TO REMAIN UPPER BEARING 9' - 10" AFF WOOD DECK 0' - 0" AFF RIDGE HT. 14' - 4" AFF 6 A2.0 ROOF BEARING (V.I.F.) 7' - 6" AFF 22 GA. STANDING SEAM MTL. ROOF PT RAILING, TO MATCH EXIST 2X8 PT WD RAFTERS, SEE STRUCT. EXIST. RF. TO REMAIN UPPER BEARING 9' - 10" AFF A2.0 3 6 A2.0 A2.05A2.0 4 10" / 12" 10" / 12" 4" / 12" 22 GA. STANDING SEAM MTL. ROOF 7 A2.0 V.I.F. 10" 3" V.I.F. 10" EXIST. RF. TO REMAIN NOTE: PAVILION ROOF TO ALIGN WITH EXIST ROOF., WHILE MAINTAINING MIN. 6'-8" CLEARANCE UNDER BEAM. TRANSITION PER MANUF. RECCOMEND. @ ASPHALT TO STANDING SEAM ROOF TRANSITION WOOD DECK 0' - 0" AFF RIDGE HT. 14' - 4" AFF ROOF BEARING (V.I.F.) 7' - 6" AFF A2.0 12 A2.0 11 A2.0 10 7 A2.0 2X8 PT WD RAFTERS, SEE STRUCT. 2X8 PT COLLAR TIE, SEE STRUCT. PT BEAMS, SEE STRUCT. 2X BLOCKING 2X10 RIDGE BEAM, SEE STRUCT. UPPER BEARING 9' - 10" AFF 10" 12" 10" 12" 4" 12" REF. 11/S2.0 FOR HIGH / LOW BEARING DETAIL ROOF BEARING (V.I.F.) 7' - 6" AFF V.I.F. 10" 4" 12" 22 GA STANDING SEAM MTL. RF. 2X6 T&G DECKING, SEE STRUCT. HIGH TEMP. ICE & WATER SHIELD CLIP, SEE STRUCT. ATTACHMENT, SEE STRUCT. 2X BLOCKING, SEE STRUCT. MTL. RF. FLASHING PT RAFTERS, SEE STRUCT. PT BEAMS, SEE STRUCT. PT COLUMN, SEE STRUCT. ROOF BEARING (V.I.F.) 7' - 6" AFF 10" 12" 22 GA STANDING SEAM MTL. RF. 2X6 T&G DECKING, SEE STRUCT. HIGH TEMP. ICE & WATER SHIELD CLIP, SEE STRUCT. ATTACHMENT, SEE STRUCT. 2X BLOCKING, SEE STRUCT. MTL. RF. FLASHING PT RAFTERS, SEE STRUCT. PT BEAMS, SEE STRUCT. PT COLUMN, SEE STRUCT. V.I.F. 10" WOOD DECK 0' - 0" AFF 6X6 PT COLUMN, BEYOND 4X4 PT WD POST W/ CAP, TO MATCH. EXIST. PT WD RAILING, TO MATCH. EXIST WD DECK, EXIST. TO REMAIN EMBEDDED POST FOUNDATION, BEYOND, SEE STRUCT. WOOD DECK 0' - 0" AFF RIDGE HT. 14' - 4" AFF 6 A2.0 ROOF BEARING (V.I.F.) 7' - 6" AFF EXISTING BUILDING TO REMAIN 3X8 PT RAFTER AT END, SEE STRUCT. 3X8 PT RAFTER AT END, SEE STRUCT. 2X8 PT COLLAR TIE, SEE STRUCT. 2X6 PT T&G DECKIING 3" PT BEAM, SEE STRUCT. PT RAILING, TO MATCH EXIST. 6X6 PT COLUMN UPPER BEARING 9' - 10" AFF POST OFFICE BOX 3978 BLUFFTON, SC 29910 PH: 843.815.2557 FX: 843.815.2547 WWW.COURTATKINS.COM ISSUE PROJECT INFO SHEET TITLE Date Project No. COPYRIGHT 2024 COURT ATKINS GROUP - THIS DRAWING IS THE PROPERTY OF THE ARCHITECT AND IS NOT TO BE REPRODUCED IN WHOLE OR IN PART BY ANY MEANS OR METHOD WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ARCHITECT. ANY UNAUTHORIZED REPRODUCTION OR REUSE OF THESE DOCUMENTS WILL RESULT IN LEGAL ACTION. NOT FOR C ONSTRU CTION NOT FOR C ONSTRU CTION © 5/30/2025 12:09:44 PM 05.30.2025 25-021 FLOOR PLAN, ELEVATIONS, SECTIONS AND DETAILS A2.0 SWEET AL'S CAFE PAVILION RENOVATION 1 NORTH BEACH DRIVE UNIT 1A HILTON HEAD ISLAND, SOUTH CAROLINA 29928 1/4" = 1'-0"A2.0 1 FLOOR PLAN 1/4" = 1'-0"A2.0 3 FRONT ELEVATION 1/4" = 1'-0"A2.0 4 LEFT ELEVATION 1/4" = 1'-0"A2.0 5 RIGHT ELEVATION 1/4" = 1'-0"A2.0 2 ROOF PLAN A2.0 8 PERSPECTIVE A 1/4" = 1'-0"A2.0 6 BUILDING SECTION A NO. REV. DATE DESCRIPTION A2.0 9 PERSPECTIVE B 1" = 1'-0"A2.0 12 3/12 OVERHANG DETAIL 1" = 1'-0"A2.0 11 10/12 OVERHANG DETAIL 1" = 1'-0"A2.0 10 RAILING DETAIL 1/4" = 1'-0"A2.0 7 BUILDING SECTION B err,ow "Pe,s° 6f......5%se" "·.%%gs cour 'zn: art :;-rw o :-Ek:ARCHITECTS, NC.: S :BUFTON, SC ;0001g ¢Asi· l. ,%· ·¢;sp.<":S?so mg2""Pp% grCOURT ATKINSGROUP -------4 0 0 -----$- 11 , ¥7°][ 7] %9±EA 0 l e L 0 , II II II II II II 1111 1111 rnnr= = n j > 0 = I= _L - - - f 1,ee )t t IT II II 0 « } I M II II I 1111 11 II II II 1 1111 II II - -- 1111- -- -! - -- -- -- -- tt11- - - -- --n It -- _J Ill l ±» IT 7i 0 )• .----4 II I 5 - - :s::J._ 4-------4 0 + =nat•1111 i 0 0 )0 nu ll 7177 1 [Ill__._- l,kl=et ] --------4 j 9 --------------------------------------$- 1/ ~ ~/'-,_~--r- $./ mo- is ii 0 0 0 0 Page 14 of 22 EXTENT OF WORK METAL ROOF SENTRICALD - CLASSIC GREEN, TO MATCH EXIST. DEVELOPMENT COLUMNS, BEAMS, RAFTERS & RAILINGS PRESSURE TREATED WOOD COURT ATKINS GROUP 32 BRUIN ROAD, BLUFFTON, SC 29910 +1 843 815 2557 RESIDENTIAL | COMMERCIAL | INTERIORS © COPYRIGHT 2024 COURT ATKINS GROUP - THIS DRAWING IS THE PROPERTY OF THE ARCHITECT AND IS NOT TO BE REPRODUCED IN WHOLE OR IN PART BY ANY MEANS OR METHOD WITHOUTTHE EXPRESS WRITTEN CONSENT OF THE ARCHITECT. ANY UNAUTHORIZED REPRODUCTION OR REUSE OF THESE DOCUMENTS WILL RESULT IN LEGAL ACTION. SWEET AL'S CAFE PAVILION RENOVATION 03.10.2026 I COURT AIKINSg9 Gou Page 15 of 22 NOTE: THE PURPOSE OF THIS PROJECT AS WE UNDERSTAND IT IS TO REPLACE AN EXISTING CANVAS & METAL ROOF STRUCTURE INSTALLED AT THE FRONT OF AN EXISTING RESTAURANT TO COVER A DECK WITH SITTING AREAS. THE REPLACEMENT STRUCTURE HAS BEEN DESIGNED IN ACCORDANCE WITH THE CURRENT CODES AS LISTED ON THIS SHEET. THE DESIGN FOR THIS STRUCTURE UTILIZES THE NEW ELEMENTS TO SUPPORT ALL LOADINGS AND DOES NOT TRANSFER ANY LOADING BACK TO THE EXISTING STRUCTURE. THIS PROPOSED SCOPE OF THIS PROJECT DOES NOT REDUCE THE CAPACITY OR INCREASE THE APPLIED LOADING TO THE EXISTING BUILDING, THEREFORE CONSIDERATION OF THIS STRUCTURE HAS NOT BEEN INCLUDED IN OUR WORK. GENERAL REQUIREMENTS 1. WHERE A SECTION OR DETAIL IS SHOWN FOR ONE CONDITION, IT SHALL APPLY TO ALL SIMILAR CONDITIONS. 2. COORDINATE ALL LIMITS AND DEPTHS OF DEPRESSIONS FOR FLOOR FINISHES WITH ARCHITECTURAL DRAWINGS AND SCHEDULES. LIMITS SHOWN ON STRUCTURAL DRAWINGS ARE SCHEMATIC. 3. THE DESIGN ADEQUACY AND SAFETY OF ERECTION BRACING, SHORING, TEMPORARY SUPPORTS, ETC. SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR. 4. DO NOT SCALE DRAWINGS. FOLLOW DIMENSIONS SHOWN ON PLANS. 5. CONTRACTOR SHALL COORDINATE AND VERIFY ALL DIMENSIONS AND ELEVATIONS SHOWN HEREIN WITH ARCHITECTURAL PLANS, SECTIONS, AND DETAILS PRIOR TO CONSTRUCTION OR MATERIAL PURCHASE AND SHALL NOTIFY ARCHITECT OR ENGINEER IN WRITING OF DISCREPANCIES. SEE ARCHITECTURAL DRAWINGS FOR ALL DIMENSIONS AND ELEVATIONS NOT SHOWN HEREIN. 6. DIMENSIONS INDICATED RELATIVE TO AN EXISTING STRUCTURE ARE APPROXIMATE AND SHALL BE FIELD VERIFIED BY THE CONTRACTOR PRIOR TO CONSTRUCTION OR MATERIALS PURCHASE. CONTRACTOR SHALL NOTIFY ARCHITECT OR ENGINEER IN WRITING OF DISCREPANCIES. 7. SPECIFIED ANCHOR SYSTEMS SHALL BE INSTALLED IN STRICT ACCORDANCE WITH MANUFACTURER'S WRITTEN INSTRUCTIONS. SPECIAL ATTENTION SHALL BE GIVEN TO THE DRILLING, CLEANING, AND PREPARATION OF HOLES. WHERE ADHESIVE ANCHORS ARE SHOWN, SPECIAL ATTENTION SHALL BE GIVEN TO THE REQUIRED MIXING, APPLICATION, AND CURING TIME OF ADHESIVE TYPE SPECIFIED. STRUCTURAL NOTES PLYWOOD / GYP. BOARD SHEATHING 1. ALL PLYWOOD CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE AMERICAN PLYWOOD ASSOCIATION (APA) SPECIFICATIONS. 2. ALL ROOF PANEL SHEATHING SHALL BE PER PLAN. SUITABLE EDGE SUPPORT SHALL BE PROVIDED BY THE USE OF PANEL CLIPS OR BLOCKING BETWEEN FRAMING. 3. INSTALL ALL PLYWOOD SHEATHING AT ROOF WITH THE LONG DIMENSIONS OF THE PANEL ACROSS SUPPORTS AND WITH PANEL CONTINUOUS OVER TWO OR MORE SPANS. STAGGER PANEL END JOINTS. ALLOW 1/8" SPACING AT PANEL ENDS AND EDGES UNLESS OTHERWISE RECOMMENDED BY THE SHEATHING MANUFACTURER. 4. ALL NAILS SHALL NOT BE OVERDRIVEN. 5. PROVIDE BLOCKING AT UNSUPPORTED PANEL EDGES AS FOLLOWS: ROOFS - ONLY WHERE INDICATED ON PLAN 6. ALL PLYWOOD AND SHEATHING SHALL BE APA RATED, BEAR THE STAMP OF AN APPROVED TESTING AGENCY, AND SHALL BE FABRICATED WITH EXTERIOR GLUE. NAILS AT ABUTTING PLYWOOD EDGES MUST PENETRATE THE SAME PIECE OF FRAMING OR BLOCKING. 7. PERIMETER OF ANY OPENINGS SHALL BE FASTENED AS BOUNDARY NAILING. 8. OPENINGS WITH A DIMENSION PERPENDICULAR TO THE JOISTS GREATER THAN 4'-0" SHALL BE BLOCKED BEYOND THE HEADERS, AND METAL TIES NOT LESS THAN 16 GAGE BY 112" WIDE WITH (8)-16d COMMON NAILS ON EACH SIDE OF THE HEADER-JOIST INTERSECTION SHALL BE PROVIDED. FOUNDATIONS 1. FOUNDATIONS HAVE BEEN DESIGNED FOR 1,500 PSF MINIMUM ALLOWABLE SOIL BEARING PRESSURE. 2. REMOVE ALL WATER SOFTENED SOILS FROM FOOTING EXCAVATIONS PRIOR TO PLACING CONCRETE. FILL REMAINING VOIDS WITH ADDITIONAL CONCRETE. 3. PROVIDE 1/2" EXPANSION JOINT FILLER AROUND PERIMETER OF SLABS WHERE THEY ABUT VERTICAL SURFACES AND AT COLUMN ISOLATION JOINTS AS DETAILED. STRUCTURAL DESIGN CRITERIA DIMENSIONAL LUMBER FRAMING 1. ALL STRUCTURAL LUMBER DESIGN SHALL CONFORM TO THE REQUIREMENTS OF THE NATIONAL DESIGNS SPECIFICATION FOR WOOD CONSTRUCTION (NDS-2018). 2. LOCATION, NUMBER, AND DIMENSIONS OF FRAMING MEMBERS SHOW GENERAL ARRANGEMENT ONLY. ACTUAL SPANS, SPACING, ETC. SHALL BE DETERMINED FROM ARCHITECTURAL DETAILS. 3. SEE ARCHITECTURAL PLANS AND DETAILS FOR EDGE SECTIONS, HEADER AND LINTEL LOCATIONS, AND ALL NON-STRUCTURAL FRAMING AND TRIM. 4. ALL WOOD FRAMING MATERIAL SHALL BE SURFACED DRY AND USED AT 19% MAXIMUM MOISTURE CONTENT. ALLOWABLE STRESS REQUIREMENTS OF ALL MATERIALS SHALL BE IN ACCORDANCE WITH THE "SCHEDULE OF REQUIRED STRESS VALUES". 5. ALL STUD AND WALL FRAMING SHALL BE NO. 2 GRADE SOUTHERN YELLOW PINE (SYP). "STUD" GRADE MATERIAL IS STRICTLY PROHIBITED FROM USE. 6. ALL JOIST, RAFTER & MISC. FRAMING SHALL BE NO. 2 GRADE, SOUTHERN YELLOW PINE. PROVIDE FULL-DEPTH BLOCKING AT ENDS. PROVIDE FULL-DEPTH (OR METAL) BRIDGING AT MIDSPAN AND AT A MAXIMUM SPACING OF 8'-0" O.C. IN BETWEEN. 7. ALL LUMBER EXPOSED TO EXTERIOR ENVIRONMENT OR IN CONTACT WITH MASONRY OR CONCRETE SHALL BE PRESSURE TREATED TO A MINIMUM RETENTION OF 0.25 lbs. OF ACQ PER CUBIC FOOT OF WOOD, AND EACH PIECE SHALL BEAR THE THIRD PARTY QUALITY MARK, "ABOVE GRADE USE". ALL LUMBER IN CONTACT WITH THE GROUND SHALL BE PRESSURE TREATED TO A MINIMUM RETENTION OF 0.40 lbs. OF ACQ PER CUBIC FOOT OF WOOD, AND EACH PIECE SHALL BEAR THE THIRD PARTY QUALITY MARK, "GROUND CONTACT USE". REFERENCE STANDARD AWPA C2 AND ASTM D1760 FOR PRESSURE TREATMENT OF TIMBER PRODUCTS. 8. WHERE POSSIBLE ALL CUTS AND HOLES SHOULD BE COMPLETED BEFORE TREATMENT. CUTS AND HOLES DUE TO ON-SITE FABRICATION SHALL BE BRUSHED WITH 2 COATS OF COPPER NAPHTHENATE SOLUTION CONTAINING A MINIMUM OF 2% METALLIC COPPER IN SOLUTION (PER AWPS STD. M4). 9. THE CONTRACTOR SHALL CAREFULLY SELECT LUMBER TO BE USED IN LOAD BEARING APPLICATIONS. THE LENGTH OF SPLIT ON THE WIDE FACE OF 2" NOMINAL LOAD BEARING FRAMING SHALL BE LIMITED TO LESS THAN ½ OF THE WIDE FACE DIMENSION. THE LENGTH OF SPLIT ON THE WIDE FACE OF 3" (NOMINAL) AND THICKER LUMBER SHALL BE LIMITED TO HALF OF THE NARROW FACE DIMENSIONS. 10. ALL WOOD JOISTS AND HEADERS WHICH FRAME INTO BEAMS SHALL BE SUPPORTED BY SIMPSON LUS HANGERS WITH THE SAME WIDTH AND DEPTH OF THE MEMBER, U.N.O. USE HANGERS WITH CONCEALED FLANGES WHERE THE CONNECTOR CANNOT BE HIDDEN BY WOOD TRIM OR THE SUPPORT MEMBER IS WIDER THAN THE STANDARD FLANGE. 11. PROVIDE NAILING PATTERN IN COMPLIANCE WITH IBC RECOMMENDED FASTENING SCHEDULE. 12. LOAD BEARING STUD WALLS SHALL BE CONTINUOUSLY BRIDGED AT MID-HEIGHT AND UNSUPPORTED PLYWOOD WALL SHEATHING JOINTS WITH SOLID WOOD BLOCKING, U.N.O. 13. NO CUTS, HOLES, OR COPES IN STRUCTURAL WOOD FRAMING SHALL BE PERMITTED WITHOUT PRIOR REVIEW AND APPROVAL BY THE STRUCTURAL ENGINEER AND ARCHITECT. 14. PROVIDE FULL-DEPTH BLOCKING AT ENDS OF RAFTERS AND JOISTS. PROVIDE FULL-DEPTH (OR METAL) BRIDGING AT MIDSPAN AND AT A MAXIMUM SPACING OF 8'-0" O.C. IN BETWEEN. 15. STRUCTURAL STEEL PLATE CONNECTORS SHALL CONFORM TO ASTM A36 SPECIFICATIONS AND BE ¼" THICK UNLESS OTHERWISE INDICATED. BOLTS CONNECTING WOOD MEMBERS SHALL BE PER ASTM A307 AND BE 34" DIAMETER UNLESS OTHERWISE INDICATED. PROVIDE WASHERS FOR ALL BOLT HEADS AND NUTS IN CONTACT WITH WOOD SURFACES. 16. BOLT HOLES SHALL BE CAREFULLY CENTERED AND DRILLED NOT MORE THAN 1/16" LARGER THAN THE BOLT DIAMETER. BOLTED CONNECTIONS SHALL BE SNUG TIGHT BUT NOT TO THE EXTENT OF CRUSHING WOOD UNDER WASHERS. 17. HOLES AND NOTCHES DRILLED OR CUT INTO WOOD FRAMING SHALL NOT EXCEED THE REQUIREMENTS OF IBC, SECTION 23. 18. ALL PLATES, ANCHORS, NAILS, BOLTS, NUTS, WASHERS, AND OTHER MISCELLANEOUS HARDWARE INSTALLED IN PRESSURE TREATED LUMBER, SHALL BE HOT DIP GALVANIZED. 19. ADEQUATE BRACING SHALL BE PROVIDED UNTIL PERMANENT BRACING AND/OR DIAPHRAGMS ARE INSTALLED. 20. OVERLAP ALL TOP PLATES AT CORNERS. 21. JOINTS IN THE DOUBLE TOP PLATES OF WALLS SHALL BE OFFSET A MINIMUM LAP LENGTH OF 4'-0" & NAILED WITH NOT LESS THAN (15)-16d FACE NAILS ON EACH SIDE OF THE JOINT. 22. ALL BEAMS SHALL HAVE LATERAL SUPPORT AT THE COMPRESSION EDGE AT A MAXIMUM OF 24" O.C. AND AT BEARING POINTS, WITH A MINIMUM BEARING LENGTH OF 3 1/2". 23. PROVIDE DOUBLE JOISTS OR SOLID BLOCKING AT 24" O.C. UNDER ALL PARTITIONS AND TO SUPPORT CONCENTRATED LOADS FROM FRAMING ABOVE UNLESS NOTED OTHERWISE. 24. PROVIDE DOUBLE HEADER BEAMS OF THE SAME SIZE AS JOISTS OR RAFTERS TO FRAME AROUND OPENINGS IN PLYWOOD DECK UNLESS OTHERWISE INDICATED. 25. PROVIDE DOUBLE LAYER PLYWOOD UNDER ALL CERAMIC OR STONE TILE FLOORS. 26. PROVIDE HEADERS, BRIDGING, CONNECTORS, BLOCKING, TRIMMERS, ETC. AS REQUIRED AND RECOMMENDED BY AITC TIMBER CONSTRUCTION STANDARDS AND 2021 SCBC U.N.O. 27. WOOD FRAMING MATERIALS: A. ALL DIMENSIONAL LUMBER SHALL BE #2 SYP KD OR BETTER AND PROVIDE NOT LESS THAN THE FOLLOWING ALLOWABLE STRESSES: Fb = 1,000 PSI Ft = 600 PSI E = 1,400,000 PSI Fc = 1,400 PSI Fcp = 565 PSI B. SHEATHING: WALLS..............................................APA RATED SHEATHING, EXPOSURE 1 OR EXTERIOR; ROOF................................................APA RATED SHEATHING, EXPOSURE1, 2, OR EXTERIOR; FLOOR..............................................APA RATED STURD-I-FLOOR; C. ALL BOLTS SHALL BE ASTM A307 WITH WASHERS, GALVANIZED; D. NAILS IN ACCORDANCE WITH MINIMUM NAILING REQUIREMENTS OF SCBC EXCEPT WHERE NOTED IN DETAILS OR SPECIFICATIONS. ALL NAILS TO BE GALVANIZED. CAST-IN-PLACE REINFORCED CONCRETE 1. THE FOLLOWING ACI STANDARDS (LATEST EDITION) APPLY: A. ACI 318 - CODE B. ACI 315 - DETAILING C. ACI 301 - SPECIFICATIONS D. ACI 304 - PLACING E. ACI 347 - FORMWORK F. ACI 211.1 - MIX PROPORTIONING G. ACI 305 - HOT WEATHER CONCRETING H. ACI 306 - COLD WEATHER CONCRETING 2. ALL CONCRETE SHALL BE NORMAL WEIGHT CONCRETE (145 PCF) WITH MIXES MEETING THE FOLLOWING CRITERIA: STRUCTURAL ELEMENT28 DAY COMPRESSIVE STRENGTH FOOTINGS, GRADE BEAMS & FOUNDATION WALLS3,000 PSI SLAB ON GRADE3,000 PSI ELEVATED SLABS & BEAMS4,000 PSI COLUMNS4,000 PSI 3.SLUMP SHALL NOT EXCEED 5". SLUMP TESTS SHALL BE PERFORMED ON EACH TRUCK LOAD AND CONFORM TO ASTM C143. a a GABLE FREE a = 3.6 FT WIND PRESSURES (PSF) COMPONENTS & CLADDING 2 a a 1 3 ROOF: 7 TO 45 DEGREES ZONEAREA(SF)+P -PASD +PASD -P 11019.6 49.2 16.0 29.52 120 19.6 49.2 16.029.52 150 19.6 49.2 16.029.52 1100 19.6 49.2 16.029.52 210 31.4 73.918.84 44.34 220 31.4 73.9 18.8444.34 250 31.4 73.918.8444.34 210019.649.2 16.029.52 310 39.3 98.523.58 59.1 320 31.4 73.9 18.8444.34 350 31.4 73.9 18.8444.34 3100 19.6 49.2 16.029.52 1. BUILDING CODE: 2021 SOUTH CAROLINA BUILDING CODE (SCBC) 2. GRAVITY LOADS (ASCE 7-16): DISTRIBUTED ROOF LL = 20 PSF DL = 20 PSF COLLATERAL LOAD CL = 5 PSF 3. WIND LOADS (ASCE 7-16/ 2021 SCBC): BASIC DESIGN WIND SPEED, V = 145mph ALLOWABLE STRESS DESIGN WIND SPEED, VASD = 112mph RISK CATEGORY II WIND EXPOSURE C INTERNAL PRESSURE COEFFICIENT, GC^pi = ±0.00 4. SEISMIC LOADS (ASCE 7-16/ 2021 SCBC): RISK CATEGORY II SEISMIC IMPORTANCE FACTOR, IE = 1.00 MAPPED SPECTRAL RESPONSE ACCELERATION PARAMETERS: SS = 0.55g; S1 = 0.14g SITE CLASS D DESIGN SPECTRAL RESPONSE ACCELERATION PARAMETERS: SDS = 0.38g; SD1 = 0.20g SEISMIC DESIGN CATEGORY D BASIC SEISMIC FORCE-RESISTING SYSTEM: TIMBER CANTILEVERED COLUMN SYSTEM DESIGN BASE SHEAR: V = CsW W = EFFECTIVE SEISMIC MASS SEISMIC RESPONSE COEFFICIENT, CS = 0.25 RESPONSE MODIFICATION FACTOR, R = 16.5 ANALYSIS PROCEDURE: EQUIVALENT LATERAL FORCE METHOD 5. SNOW LOAD (ASCE 7-16): GROUND SNOW LOAD Pg = 0 PSF 6. RAIN LOAD DATA 2021 SCBC: RAIN INTENSITY i = 4.5 in/hr STRUCTURAL DESIGN CONSULTANTS PROJECT No. 25-412 COPYRIGHT 2025 COURT ATKINS GROUP - THIS DRAWING IS THE PROPERTY OF THE ARCHITECT AND IS NOT TO BE REPRODUCED IN WHOLE OR IN PART BY ANY MEANS OR METHOD WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ARCHITECT. ANY UNAUTHORIZED REPRODUCTION OR REUSE OF THESE DOCUMENTS WILL RESULT IN LEGAL ACTION. © NO.REV. DATEDESCRIPTION No. 7089 SOUTH CAROLINA SHEARLOCK ENGINEERING, LLC CE NOITA RI TFICATE ZIRO OF HT AU 05.30.2025 STRUCTURAL NOTES S1.0 I I PSHEARLOCK•ENGINEERING COURT ATKINSGROUP POSTOFFICEBOX3978 BLUFFTON,SC29910 PH:843.815.2557 FX:843.815.2547 WWW.COURTATKINS.COM CX) N0 z0 0N <( _Jz >I0 <r- «3 0..- w+-,I .b LLzo <((I) LI O>- - oz0-z O<( -OI I JO- 1H-< <(Lu! H>00uj rT JO'z LIzg5 zLuO;z_ 0-T pt+u,,'ta,I,, s°2 -- -- -- -- -- -- -- -- -- PROJECTINFO Date 05.30.2025 ProjectNo. 24-021 ISSUE SHEETTITLE Page 16 of 22 - FOOTING MARK - SEE FOOTING SCHEDULE - COLUMN MARK - SEE COLUMN SCHEDULE GENERAL LEGEND F1 C1 - COLUMN FOOTING N/A F1 MARK W L T FOOTING SCHEDULE 'A' BARS'B' BARS 4'-0" 1'-6"ØN/A FRAMING NOTES: 1.ROOF SHEATHING: P.T. SYP #2 GRADE 2x6 T&G DECKING SPANNING OVER (3) RAFTERS (MIN.) & FASTENED W/ (2) #12 WOOD SCREWS @ EACH RAFTER (16" O.C. MIN.) P.T. 6x6 SOLID POSTC1 COLUMN SCHEDULE COLUMN TYPEMARK 1 S2.0 FOUNDATION PLAN SCALE: 1/4" - 1'-0" F1 F1 F1 F1 F1 F1 F1 F1 F1 6'-10"7'-414" 14'-812"6'-11" 21'-712" 14'-214" EXISTING BUILDING TO REMAIN EXISTING ON GRADE DECK TO REMAIN EXCEPT WHERE REMOVAL IS REQUIRED TO COMPLETE NEW WORK. G.C. TO REPAIR TO MATCH EXISTING CONDITION WHEN COMPLETE. OFFSET FOOTING TO AVOID EXISTING BUILDING FOUNDATION WHILE MAINTAINING MINIMUM CONCRETE COVERAGE PER DETAIL. NOTIFY E.O.R. IF UNABLE TO ACHIEVE INTENT BASED ON SITE CONDITIONS NOTE: COLUMN LOCATIONS ARE APPROXIMATE & SHALL BE VERIFIED IN FIELD TO AVOID EXISTING UTILITIES, STRUCTURES & PLANTINGS. INTENT IS TO MATCH EXISTING GEOMETRY. 2 S2.0 BEAM FRAMING PLAN SCALE: 1/4" - 1'-0" C1 C1 C1 P.T. 3x10 P.T. 3x10 (CONT.) P.T. 3x10 (CONT.) C1 C1 C1C1 C1 C1 P.T. 3x10 EACH SIDE (CONT.) - HIGH @ SHED ROOF BEARING P.T. 3x10 (CONT.) P.T. 3x8 (CONT.) P.T. 3x10 8 S2.0 EXISTING BUILDING TO REMAIN SIM. NOTE: INTENT IS FOR BEAMS TO ALIGN W/ EXISTING PLATE HEIGHT OF BUILDING. VERIFY IN FIELD. P.T. 3x10 LOCATE END BEAM @ FACE OF EXISTING BUILDING, BUT DO NOT CONNECT EXCEPT AS REQUIRED FOR FINISHES & FLASHING REFER TO DETAIL 5/S300 FOR TYPICAL BEAM TO COLUMN CONNECTION P.T. 3x10 EXISTING RAILING BELOW TO REMAIN - U.N.O. BY ARCH. 5 S2.0 6 S2.0 11 S2.0 2x8 COLLAR TIES @ 16" O.C. (BOTTOM EL. 10'-0" A.F.F.) 7 S2.0 P.T. 3x8 (CONT.) - LOW @ COMMON BEAM ELEVATION P.T. 3x10 (CONT.) - LOW @ COMMON BEAM ELEVATION 10" / 12"10" / 12"4" / 12" 3 S2.0 ROOF FRAMING PLAN SCALE: 1/4" - 1'-0" EXISTING BUILDING TO REMAIN P.T. 3x8 END RAFTER BOTH SIDES WITH OPEN GABLE BELOW (TYP.) COLUMN BELOW SIM. 11 S2.0 OVERBUILD - SEE 9/S300 10 S2.0 P.T. 2x10 RIDGE BOARD 7 S2.0 5 S2.0 6 S2.0 9 S2.0 LOCATE END GABLE RAFTER @ FACE OF EXISTING BUILDING, BUT DO NOT CONNECT EXCEPT AS REQUIRED FOR FINISHES & FLASHING BEAM BELOW (TYP.) 2x8 @ 16" O.C. 2x8 @ 16" O.C. 2x8 @ 16" O.C. 4 S2.0 EMBEDDED POST FOUNDATION NOT TO SCALE 4'-0" (MIN.) COMPACTED SUBGRADE - SEE STRUCTURAL NOTES 1'-6"Ø SECTION A-A A A 4" CLR. (MIN.) 3000psi CONCRETE FOOTING Ø1'-6" MASONRY BRICK AT BOTTOM OF FOOTING GROUND CONTACT RATED POST - SEE PLAN 4" CLR. (MIN.) SLOPESLOPE (2)-#5x12" BARS THROUGH POST TOP & BOTTOM 2x BLOCKING (2) #12 3" WOOD SCREW THROUGH BLOCKING INTO EACH RAFTER SIMPSON STRONG-TIE LS50 OR EQUAL, AT EACH RAFTER T&G DECKING - SEE FRAMING NOTES RAFTER - SEE PLAN RAFTER - SEE PLAN 9 S2.0 DETAIL AT OVERBUILT SHED ROOF NOT TO SCALE 8 S2.0 TYPICAL SIDELAP DETAIL NOT TO SCALE COLLAR TIE - SEE PLAN (8) 16d NAILS SIDE LAPPED INTO RAFTER T&G DECKING - SEE FRAMING NOTES ROOF FINISH - SEE ARCH. PLAN ROOF FINISH - SEE ARCH. PLAN 10 S2.0 CONNECTION AT LVL RIDGE BEAM NOT TO SCALE (2)34"Ø (MIN.) HDG CARRIAGE BOLTS THROUGH EACH BEAM & POST SEE OVERBUILD DETAIL 9/S2.0 FOR TYP. RAFTER CONDITION BEYOND (2)34"Ø (MIN.) HDG CARRIAGE BOLTS THROUGH EACH BEAM & POST 11 S2.0 BEAM CONNECTION HIGH & LOW NOT TO SCALE BEAM - SEE PLAN RAFTER - SEE PLAN RAFTER - SEE PLAN T&G DECKING - SEE FRAMING NOTES RAFTER - SEE PLAN RAFTER - SEE PLAN T&G DECKING - SEE FRAMING NOTES SIMPSON STRONG-TIE LRU28Z HANGER (TYP.) RIDGE BOARD - SEE PLAN TIMBERLOK SCREW INTO BEAM (2" MIN. PENETRATION) 5 S2.0 DETAIL AT BEAM SPLICE @ CORNER NOT TO SCALE RAFTERS - SEE PLAN ROOF FINISH - SEE ARCH PLAN COLUMN BEYOND - SEE PLAN 6 S2.0 DETAIL AT GABLE END NOT TO SCALE P.T. 3x8 END RAFTER PER PLAN (TYP.) RIDGE BEAM - SEE PLAN T&G DECKING - SEE FRAMING NOTES ROOF FINISH - SEE ARCH PLAN FASTEN ALL RAFTERS TO RIDGE W/ SLOPED FACE MOUNT HANGER - NOT SHOWN FOR CLARITY PLATE LINE SIMPSON STRONG-TIE H2.5A HURRICANE CLIP (OR EQUAL) AT EACH RAFTER TO BEAM CONNECTION 'BIRDS-MOUTH' CUT AT EACH RAFTER FOR FULL BEARING OVER BEAMS NOTCH POST FOR 1" BEARING FOR BEAMS SUPPORTING RAFTERS SECTION A-A (2)34"Ø (MIN.) HDG CARRIAGE BOLTS THROUGH EACH BEAM AND POST BEAM - SEE PLAN COLUMN - SEE PLAN BEAM BEYOND - SEE PLAN BEAM EACH SIDE OF POST - SEE PLAN (2)34"Ø (MIN.) HDG CARRIAGE BOLTS THROUGH EACH BEAM, POST, & @ BLOCKING REF. ARCH. FOR OVERHANG DIMENSIONS & FINISH GEOMETRY RAFTERS - SEE PLAN RIDGE BEAM - SEE PLAN T&G DECKING - SEE FRAMING NOTES ROOF FINISH - SEE ARCH PLAN FASTEN ALL RAFTERS TO RIDGE W/ SLOPED FACE MOUNT HANGER - NOT SHOWN FOR CLARITY REF. ARCH. FOR OVERHANG DIMENSIONS & FINISH GEOMETRY MATCH TOP OF ROOF TO EXISTING STRUCTURE TOP OF ROOF 7 S2.0 DETAIL AT GABLE END NOT TO SCALE P.T. 3x8 END RAFTER PER PLAN (TYP.) T&G DECKING - SEE FRAMING NOTES RAFTERS - SEE PLAN EXISTING STRUCTURE TO REMAIN FULL DEPTH BLOCKING BETWEEN ALL RAFTERS BLOCKING BETWEEN PLYS MATCHING GAP & DEPTH OF MEMBERS @ 6'-0" O.C. (MAX.) STRUCTURAL PLANS & DETAILS S2.0 STRUCTURAL DESIGN CONSULTANTS PROJECT No. 25-412 COPYRIGHT 2025 COURT ATKINS GROUP - THIS DRAWING IS THE PROPERTY OF THE ARCHITECT AND IS NOT TO BE REPRODUCED IN WHOLE OR IN PART BY ANY MEANS OR METHOD WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ARCHITECT. ANY UNAUTHORIZED REPRODUCTION OR REUSE OF THESE DOCUMENTS WILL RESULT IN LEGAL ACTION. © NO. REV. DATEDESCRIPTION No. 7089 SOUTH CAROLINA SHEARLOCK ENGINEERING, LLC CE NOITA RI TFICATE ZIRO OF HT AU 05.30.2025 CX) N0 z0 0N <( _Jz >I0 <r- «3 0..- w+-,I .b LLzo <((I) LI O>- - oz0-z O<( -OI I JO- 1H-< <(Lu! H>00uj rT JO'z LIzg5 zLuO;z_ 0- -T pt+u,,'ta,I,, s°2 -- -- -- -- -- -- -- -- -- POSTOFFICEBOX3978 BLUFFTON,SC29910 PH:843.815.2557 FX:843.815.2547 WWW.COURTATKINS.COM PROJECTINFO COURT ATKINSGROUP I 0t ti 0 I 0 I 0 I au-□ : 0 I ' 4 ,,B 7 ms, I I( 0 0 0 0 ProjectNo. 24-021 Date 05.30.2025 SHEETTITLE ISSUE J 0 r 000aHlSHEARLOCK I:1ENGINEERING:.@ eee, Page 17 of 22 Page 18 of 22 1 DDEESSIIGGNN TTEEAAMM//DDRRBB CCOOMMMMEENNTT SSHHEEEETT TThhee ccoommmmeennttss bbeellooww aarree ssttaaffff rreeccoommmmeennddaattiioonnss ttoo tthhee DDeessiiggnn RReevviieeww BBooaarrdd ((DDRRBB)) aanndd ddoo NNOOTT ccoonnssttiittuuttee DDRRBB aapppprroovvaall oorr ddeenniiaall.. PROJECT NAME: 1 North Forest Beach Unit: A1 DRB-000266-2026 DATE: 03/25/2026 CATEGORY: Alteration RECOMMENDATION: Approval Approval with Conditions Denial APPLICATION MATERIAL DRB REQUIREMENTS Complies Yes No Not Applicable Comments or Conditions Demolition Plan if needed Existing Conditions match As-Built Dimensioned Details and of Sections Detail Illustrating Connection to Existing Structure New Building Details Match Existing Building Details ARCHITECTURAL DESIGN DESIGN GUIDE/LMO CRITERIA Complies Yes No Not Applicable Comments or Conditions Structure is designed to be appropriate to the neighborhood Promotes pedestrian scale and circulation Design is unobtrusive and set into the natural environment Utilizes natural materials and colors Avoids distinctive vernacular styles Design is appropriate for its use All facades shall have equal design characteristics Page 19 of 22 2 Avoids monotonous planes or unrelieved repetition Has a strong roof form with enough variety to provide visual interest Overhangs are sufficient for the façade height. Forms and details are sufficient to reduce the mass of the structure Human scale is achieved by the use of proper proportions and architectural elements Utilizes a variety of materials, textures and colors Incorporates wood or wood simulating materials Windows are in proportion to the facade Details are clean, simple and appropriate while avoiding excessive ornamentation Utilities and equipment are concealed from view Decorative lighting is limited and low wattage and adds to the visual character Accessory elements are designed to coordinate with the primary structure LANDSCAPE DESIGN DESIGN GUIDE/LMO CRITERIA Complies Yes No Not Applicable Comments or Conditions Treats the Landscape as a major element of the project Provide additional plantings. Provides Landscaping of a scope and size that is in proportion to the scale of the development Landscape is designed so that it may be maintained in its natural shape and size Provide a Landscape Plan. Preserves a variety of existing native trees and shrubs Indicate how you are maintaining or enhancing the existing landscaping at the left side of the entrance and across the sidewalk. Provides for a harmonious setting for the site’s structures, parking areas or other construction Location of existing trees and new trees provides street buffers, mitigation for parking lots, and an architectural complement that visually mitigates between parking lots and building(s) Shrubs are selected to complement the natural setting, provide visual interest and screen less-desirable elements of the project A variety of species is selected for texture and color Page 20 of 22 3 Provides overall order and continuity of the Landscape plan Native plants or plants that have historically been prevalent on the Island are utilized A variety of sizes is selected to create a “layered” appearance for visual interest and a sense of depth The location of existing mature trees is taken into account in placement of shrubs so as not to damage tree roots Proper spacing and location for plants to reach their mature size and natural shape while avoiding excessive or unnatural pruning Proposed groundcovers are evergreen species with low maintenance needs Large, grassed lawn areas encompassing a major portion of the site are avoided The adjacent development is taken into account in determining the most appropriate buffer so as not to depart too dramatically from the neighborhood Ornamentals and Annuals are limited to entrances and other focal points NATURAL RESOURCE PROTECTION DESIGN GUIDE/LMO CRITERIA Complies Yes No Not Applicable Comments or Conditions An effort has been made to preserve existing trees and under story plants Supplemental and replacement trees meet LMO requirements for size, species and number Wetlands if present are avoided and the required buffers are maintained Sand dunes if present are not disturbed COMMENTS & CONDITIONS Staff recommend approval of the Alteration submittal for 1 North Forest Beach Unit: A1, with the following conditions: 1. Landscape Plan required. The applicant shall provide a landscape plan indicating the existing landscaping adjacent to the structure and demonstrating how these plantings will be maintained, relocated, or enhanced as part of the proposed alteration. 2. The Design Guide emphasizes that buildings should sit within the landscape, and landscaping should be maintained or enhanced during building alterations. 3. The landscape plan shall include plant species, quantities, and locations to ensure that the building continues to be integra ted within the landscape. Page 21 of 22 4 4. Any additional information as required by the Board. Page 22 of 22

Source: Town of Hilton Head Island website. First collected Oct 17, 2026.