1. Call to Order
2. Adoption of the Agenda
3. Approval of the Minutes
a. Regular Meeting Minutes of March 11, 2026
4. Unfinished Business
5. New Business
a. DRB-000266-2026 - 1 North Forest Beach Unit A1 - Alteration
6. Public Comment - Non Agenda Items
7. Board Business
8. Staff Reports
9. Adjournment
FOIA Compliance: Public notification of this meeting has been published, posted, and
distributed in compliance with the South Carolina Freedom of Information Act and the
requirements of the Town of Hilton Head Island.
In accordance with the requirements of Title II of the Americans with Disabilities Act of
1990 ("ADA"), the Town of Hilton Head Island will not discriminate against qualified
individuals with disabilities on the basis of disability in its services, programs, or
activities. Auditory accommodations are available. Any person requiring further
accommodation should contact the Town of Hilton Head Island ADA Coordinator as
soon as possible but no later than 48 hours before the scheduled event.
Page 1 of 22
Municipal Association of South Carolina (MASC) Civility Pledge:
“I pledge to build a stronger and more prosperous community by advocating for civil
engagement, respecting others and their viewpoints, and finding solutions for the
betterment of my city or town.”
Page 2 of 22
Town of Hilton Head Island Design Review Board
Meeting Minutes
3/11/2026 Page | 1
Town of Hilton Head Island
DESIGN REVIEW BOARD MEETING
Wednesday, March 11, 2026, 2:30 PM
Minutes
1. Call to Order
Chair Carstens called the meeting to order at 2:30 p.m.
In attendance: Judd Carstens, Annette Lippert, Megan Fitzpatrick, Todd Theodore, Tom
Parker, and Patricia Pastor
2. Adoption of the Agenda
Mr. Parker made a motion to adopt the agenda. Ms. Pastor seconded. The motion passed
unanimously.
3. Approval of the Minutes
a. Regular Meeting Minutes of February 25, 2026
Ms. Fitzpatrick made a motion to approve the minutes of February 25, 2026. Mr.
Theodore seconded. The motion passed unanimously.
4. Unfinished Business
a. DRB-000212-2026 - 840 William Hilton Parkway - The Atrium Building - Final
Chair Carstens and Mr. Tom Parker both recused themselves. Principle Planner Melissa
Paul-Leto presented The Atrium Building for final review. The applicant answered
questions from the board. Ms. Fitzpatrick made a motion to approve with the following
conditions: outdoor areas associated with the upper level spaces, such as the balcony,
shall not be utilized for commercial recreation purposes. The applicant will need to
provide a building section illustrating the relevant upper-level outdoor areas and a plan
notation clearly identifying these outdoor areas and their intended use for verification. Mr.
Theodore seconded. The motion passed unanimously.
5. New Business
a. DRB-000215-2026 - 862 William Hilton Parkway - Alteration
Chair Carstens remained recused and Mr. Tom Parker returned to the Dais. Melissa
Paul-Leto presented 862 William Hilton Parkway to the board for alterations. The
applicant answered questions from the board. Mr. Parker made a motion to approve with
the following conditions: improve integral lights in the lockers to meet guidelines
standards once submitted and confirm that the parking count is not affected by taking out
three spaces. Ms. Pastor seconded. The motion passed 4:1.
Page 3 of 22
Town of Hilton Head Island Design Review Board
Meeting Minutes
3/11/2026 Page | 2
6. Public Comment - Non Agenda Items
Chair Carstens returned to the dais. Martin Lesch made a public comment regarding board
ethics.
7. Board Business
a. Discussion of proposed updates to the existing Design Guide and direction on
advancing the updated Design Guide.
Melissa Paul-Leto presented the Board's remaining comments regarding multiple
elements of the Design Guide. Board members discussed their concerns and provided
additional clarification and elaboration on their feedback. A draft of the Design Guide will
be presented at the March 25, 2026, meeting.
8. Staff Reports
9. Adjournment
The meeting adjourned at 4:36 p.m.
Page 4 of 22
Page 5 of 22
Last Revised 01/21/15 1
Applicant/Agent Name: ______________________________ Company: _____________________________________
Mailing Address: ___________________________________ City: _________________ State: ______ Zip: ________
Telephone: ___________________ Fax: _________________ E-mail: _______________________________________
Project Name: _________________________________ Project Address: _____________________________________
Parcel Number [PIN]: R__ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __
Zoning District: _______________________________ Overlay District(s): ___________________________________
Town of Hilton Head Island
Community Development Department
One Town Center Court
Hilton Head Island, SC 29928
Phone: 843-341-4757 Fax: 843-842-8908
www.hiltonheadislandsc.gov
CORRIDOR REVIEW, MAJOR
DESIGN REVIEW BOARD (DRB) SUBMITTAL REQUIREMENTS
Digital Submissions may be accepted via e-mail by calling 843-341-4757.
Project Category:
_____ Concept Approval – Proposed Development _____ Alteration/Addition
_____ Final Approval – Proposed Development _____ Sign
FOR OFFICIAL USE ONLY
Date Received: _____________
Accepted by: ______________
DRB #:___________________
Meeting Date: _____________
Submittal Requirements for All projects:
_____ Private Architectural Review Board (ARB) Notice of Action (if applicable): When a project is within the
jurisdiction of an ARB, the applicant shall submit such ARB’s written notice of action per LMO Section 16-
2-103.I.4.b.iii.01. Submitting an application to the ARB to meet this requirement is the responsibility of the
applicant.
_____
Filing Fee: Concept Approval-Proposed Development $175, Final Approval – Proposed Development $175,
Alterations/Additions $100, Signs $25; cash or check made payable to the Town of Hilton Head Island.
Additional Submittal Requirements:
Concept Approval – Proposed Development
_____ A survey (1"=30' minimum scale) of property lines, existing topography and the location of trees meeting the
tree protection regulations of Sec. 16-6-104.C.2, and if applicable, location of bordering streets, marshes and
beaches.
_____ A site analysis study to include specimen trees, access, significant topography, wetlands, buffers, setbacks,
views, orientation and other site features that may influence design.
_____ A draft written narrative describing the design intent of the project, its goals and objectives and how it
reflects the site analysis results.
_____ Context photographs of neighboring uses and architectural styles.
_____ Conceptual site plan (to scale) showing proposed location of new structures, parking areas and landscaping.
_____ Conceptual sketches of primary exterior elevations showing architectural character of the proposed
development, materials, colors, shadow lines and landscaping.
SWEET AL'S CANOPY REPLACEMENT
JACOB WOODS
P.O. BOX 3978
843-815-2557 843-815-2547
COURT ATKINS GROUP
BLUFFTON SC 29910
JACOB.WOODS@COURTATKINS. COM
1 NORTH FOREST BEACH DRIVE UNIT 1A
552 018 000 0009 0000
CR- COLIGNY RESORT CORRIDOR OVERLAY
DISTRICT CR
X
Page 6 of 22
Last Revised 01/21/15 2
N
ote: All application items must be received by the deadline date in order to be reviewed by the DRB per LMO Appendix D: D-23.
A representative for each agenda item is strongly encouraged to attend the meeting.
Are there recorded private covenants and/or restrictions that are contrary to, conflict with, or prohibit
the proposed request? If yes, a copy of the private covenants and/or restrictions must be submitted with
this application.
YES NO
T
o the best of my knowledge, the information on this application and all additional documentation is true,
factual, and complete. I hereby agree to abide by all conditions of any approvals granted by the Town of Hilton
Head Island. I understand that such conditions shall apply to the subject property only and are a right or
obligation transferable by sale.
I f
urther understand that in the event of a State of Emergency due to a D isaster, the review and approval times
set forth in the Land Management Ordinance may be suspended.
SIGNATURE DATE
Additional Submittal Requirements:
Final Approval – Proposed Development
_____ A final written narrative describing how the project conforms with the conceptual approval and design
review guidelines of Sec. 16-3-106.F.3.
_____ Final site development plan meeting the requirements of Appendix D: D-6.F.
_____ Final site lighting and landscaping plans meeting the requirements of Appendix D: D-6.H and D-6.I.
_____ Final floor plans and elevation drawings (1/8"=1'-0" minimum scale) showing exterior building materials and
colors with architectural sections and details to adequately describe the project.
_____ A color board (11"x17" maximum) containing actual color samples of all exterior finishes, keyed to the
elevations, and indicating the manufacturer's name and color designation.
_____ Any additional information requested by the Design Review Board at the time of concept approval, such as
scale model or color renderings, that the Board finds necessary in order to act on a final application.
Additional Submittal Requirements:
Alterations/Additions
_____ All of the materials required for final approval of proposed development as listed above, plus the following
additional materials.
_____ A survey (1"=30' minimum scale) of property lines, existing topography and the location of trees meeting the
tree protection regulations of Sec. 16-6-104.C.2, and if applicable, location of bordering streets, marshes and
beaches.
_____ Photographs of existing structure.
Additional Submittal Requirements:
Signs
_____ Accurate color rendering of sign showing dimensions , type of lettering, materials and actual color samples.
For freestanding signs:
_____ Site plan (1”=30’ minimum scale) showing location of sign in relation to buildings, parking, existing signs,
and property lines.
_____ Proposed landscaping plan.
For wall signs:
_____ Photograph or drawing of the building depicting the proposed location of the sign.
_____ Location, fixture type, and wattage of any proposed lighting.
Page 7 of 22
Page 8 of 22
March 10, 2026
Town of Hilton Head Island
Melissa Paul-Leto, Principal Planner of Design
1 Town Center Court
Hilton Head Island, South Carolina 29928
melissapl@hiltonheadislandsc.gov
Re: Major Corridor Submittal for Sweet Al’s Canopy Modification (1 North Forest Beach
Unit A1 )
Melissa,
Please see the attached submittal for the modifications to the canopy at Sweet Al’s,
including the following:
- Design Review Application
- Architectural Drawings
- Site Plan
- Color Board
- Photographs of Existing Structure
The new +/- 350 SF canopy will replace the existing fabric canopy over the outdoor seating
area at Sweet Al’s. The framing will be PT wood with posts, columns and open rafters,
matching the details around Coligny Plaza. The roof will be standing seam, to match the
existing green standing seam around the development.
Per Sec. 16-3-106.F.3., this structure will be an aesthetic upgrade over the existing
deteriorating canopy and will tie harmoniously into the architecture of the Coligny Plaza
development.
If you have any questions or need any additional information, please let me know.
Court Atkins Architects, Inc.
Jacob Woods, Project Leader
COURT ATKINS GROUP 32 BRUIN ROAD, BLUFFTON, SC29910 +1843 815 2557
T
RESIDENTIAL I COMMERCIAL I INTERIORS
n0C22
?v .577
zD
Page 9 of 22
PHOTOGRAPHS OF EXISTING STRUCTURE
ua-
0aLuI
bz
l<uaLuI
--0u
l<{
ezuI
ouLuI
a-
pLf"I
Lu
(Lu
0O
M
tO
7
o
OO(4
uu
z0-•LL
::,_J
co
0<1
0or-
z::,rco
(M
a::>
0a0uz:,,:
b<4
ba::>
0u
COURT ATKINSGROUP
Page 10 of 22
Page 11 of 22
GENERAL NOTES:
A. NOTE TO GENERAL CONTRACTORS: THESE DRAWINGS HAVE BEEN
PRODUCED UNDER A LIMITED SERVICES AGREEMENT BETWEEN THE
OWNER/OWNER'S REPRESENTATION AND COURT ATKINS ARCHITECTS,
INC. THEY ARE TO BE USED FOR DESIGN INTENT AND IN COORDINATION
WITH SUPPLEMENT ENGINEERING DOCUMENTS.
B. THE ARCHITECT'S DRAWINGS CANNOT STAND ALONE AS CONSTRUCTION
DOCUMENTS.
C. SEE STRUCTURAL ENGINEERING DOCUMENTS FOR STRUCTURAL
CONNECTION TECHNIQUES, CALCULATIONS REQUIRED BY CODE, CODE
COMPLIANCE INSTRUCTIONS FOR WALL AND ROOF CONSTRUCTION, AND
TIE DOWN REQUIREMENTS.
D. SEPARATE MECHANICAL, ELECTRICAL, AND PLUMBING ENGINEERING
DOCUMENTS MAY BE PROVIDED, WHICH INDICATE REQUIRED SERVICE AND
RISER DIAGRAMS, CALCULATIONS AND INSTALLATION SPECIFICATIONS
BEYOND THE ARCHITECT'S BASIC LAYOUT AND SELECTIONS SUGGESTIONS.
E. SEPARATE CIVIL ENGINEERING DOCUMENTS MAY BE PROVIDED, WHICH
INDICATE ADDITIONAL SITE PLANNING, DRAINAGE, AND OTHER RELATED
SITE WORK REQUIREMENTS.
F. SELECTIONS NOT INCLUDED IN THESE DOCUMENTS WILL BE COORDINATED
BY THE OWNER / OWNER'S REPRESENTATIVES.
G. BY APPLYING FOR A BUILDING PERMIT AND/OR CONSTRUCTING THE
PROJECT REPRESENTED HEREIN, THE OWNER AGREES TO LIMIT THE LIABILITY
OF THE ARCHITECT TO THE OWNER OF THE PROJECT FOR ALL AND ANY
CLAIMS, LOSSES, DAMAGES OR ANY NATURE WHATSOEVER, OR CLAIMS OF
EXPENSES FOR ANY SUCH ITEMS TO THE ARCHITECT'S TOTAL
COMPENSATION FOR SERVICES RENDERED HEREIN.
H. THESE DOCUMENTS ARE THE WORK INSTRUMENTS OF THE ARCHITECT AND
HAVE BEEN PREPARED SPECIFICALLY AND SOLELY FOR THE PROJECT NAMED
HEREIN. THEY ARE NOT SUITABLE FOR USE ON OTHER PROJECTS OR IN
OTHER LOCATIONS WITHOUT THE PARTICIPATION OF THE ARCHITECT.
REPRODUCTION IS STRICTLY PROHIBITED. THE ARCHITECT SHALL BE DEEMED
THE AUTHOR AND OWNER OF THESE DOCUMENTS AND SHALL RETAIN
COMMON LAW, STATUTORY AND OTHER RESERVED RIGHTS, INCLUDING
THE COPYRIGHT.
I. THE ARCHITECT HAS NOT BEEN CONTRACTED TO PERFORM
CONSTRUCTION ADMINISTRATION/ ON-SITE OBSERVATION FOR THIS
PROJECT.
J. FOR DIMENSIONS NOT SHOWN OR IN QUESTION, THE CONTRACTOR WILL
REQUEST CLARIFICATION FROM THE ARCHITECT BEFORE PROCEEDING.
K. CONTRACTOR WILL VERIFY ALL EXISTING CONDITIONS IN THE FIELD. ANY
DISCREPANCIES WILL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT.
L. THE CONTRACTOR SHALL MAINTAIN AT THE SITE OF THE WORK, A SET OF
RECORD DRAWINGS. THE CONTRACTOR SHALL RECORD ALL CHANGES AND
DEVIATIONS FROM THE DRAWINGS ON THIS "AS-BUILT" SET, WHICH SHALL
BE UPDATED AT LEAST EVERY OTHER WEEK. AT THE CLOSE OF THE JOB, THE
CONTRACTOR SHALL PROVIDE ONE COMPLETE SET OF ALL AS-BUILT
INFORMATION TO THE ARCHITECT IN CLEAR AND LEGIBLE FORMAT.
M. SIGNS SHALL BE LIMITED TO THE PROJECT IDENTIFICATION SIGN. THE
IDENTIFICATION SIGN SHALL IDENTIFY THE PROJECT, THE ARCHITECT AND
THE CONTRACTOR.
N. INFORMATION CONTAINED ON THESE DRAWINGS IS PROVIDED FOR THE
CONVENIENCE OF THE GENERAL CONTRACTOR IN EXECUTING THE WORK.
EVERY ATTEMPT HAS BEEN MADE TO PROVIDE COMPLETE AND ACCURATE
REPRESENTATIONS OF SUCH CONDITIONS.
O. WHEN ARCHITECTURAL DRAWINGS ARE IN CONFLICT WITH ENGINEERING
DRAWINGS THE GENERAL CONTRACTOR SHALL REQUEST CLARIFICATION
FROM THE ARCHITECT BEFORE PROCEEDING.
PROJECT TEAM:
ARCHITECT
COURT ATKINS ARCHITECTS, INC.
32 BRUIN ROAD
P.O. BOX 3978
BLUFFTON, SC 29910
(843) 815-2557 PH
(843) 815-2547 FAX
GENERAL CONTRACTOR
TBD
LANDSCAPE ARCHITECT
N/A
CIVIL ENGINEER
N/A
OWNER CONTACT
THE RICHARDSON GROUP, LLC
P.O. BOX 6133
HILTON HEAD ISLAND, SC 29938
CONTACT: MR. COLLINS RICHARDSON
(843) 686-6929
CRICHARDSON@RICHARDSONGRP.COM
STRUCTURAL ENGINEER
SHEARLOCK ENGINEERING, LLC
110 TRADERS CROSS, SUITE 232
OKATIE, SC 29909
(843) 473-8767 PH
MECHANICAL, PLUMBING & FIRE PROTECTION
N/A
ELECTRICAL ENGINEER
N/A
INTERIOR DESIGNER
N/A
PROJECT INFORMATION:
NAME OF PROJECT: SWEET AL'S CAFE PAVILION
ADDRESS: 1 NORTH BEACH DRIVE UNIT 1A
HILTON HEAD ISLAND, SOUTH CAROLINA 29928
PROPOSED USE: ASSEMBLY (A-2)
OWNER CONTACT: THE RICHARDSON GROUP, LLC
CODE ENFORCEMENT JURISDICTION: HILTON HEAD ISLAND
INTERNATIONAL BUILDING CODE (IBC): 2021
INTERNATIONAL MECHANICAL CODE: 2021
INTERNATIONAL PLUMBING CODE: 2021
THE NATIONAL ELECTRICAL CODE: 2020
INTERNATIONAL FUEL GAS CODE: 2021
INTERNATIONAL FIRE CODE: 2021
INTERNATIONAL ENERGY CONSERVATION CODE: 2009
ICC/ANSI A117.1: 2017
DESIGNER OF RECORD:
DESIGNER NAME LICENSE NO. TELEPHONE NO.
ARCHITECTURAL JAMES C. ATKINS SC #6743 (843) 815-2557
ELECTRICAL N/A XX #XXXX (###) ###-####
PLUMBING/FIRE PROTECTION N/A XX #XXXX (###) ###-####
MECHANICAL N/A XX #XXXX (###) ###-####
STRUCTURAL JAKE EAVENSON SC #33500 (843) 473-8767
CIVIL N/A XX #XXXX (###) ###-####
LAND PLANNING/ N/A XX #XXXX (###) ###-####
LANDSCAPE
VICINITY MAP - N.T.S.
SITE
POPE AVE N FOREST BEACH DRIVE
AVOCET RD
PROJECT DESCRIPTION:
THE REPLACEMENT OF AN EXISTING CANOPY OVER THE OUTDOOR DINING DECK FOR SWEET AL'S
CONSTRUCTION:
WOOD CONSTRUCTION WITH EMBEDDED 6X6 PT POSTS, PT BEAMS AND PT OPEN RAFTERS WITH T&G WD
SUBSTRATE AND STANDING SEAM METAL ROOFING
GROSS BUILDING AREA:
OVERALL AREA (OUTSIDE OF EXTERIOR WALL): 344 SQ. FT.
BUILDING CODE SUMMARY
ALLOWABLE HEIGHT, STORIES & AREA (PER IBC TABLE 504.3, 504.4 & 506.2):
ASSEMBLY (A -2)
ALLOWABLE ACTUAL
HEIGHT: 40 FEET ±14'-4"
S
TORIES: 1 STORIES 1 STORIES
A
REA: 6,000 SQ. FT. 344 SQ. FT .
A
REA INCREASE? Yes _______ No _______
HEIGHT INCREASE? Yes _______ No _______
OCCUPANT LOAD (IBC TABLE 1004.5): OCCUPANCY (A -2)
NO CHANGE TO OCCUPANT LOAD -- STRUCTURE IS TO REPLACE EXISTING CANOPY / NO CHANGE TO AREA
EXITS (IBC TABLE 1006.3.3):
REQUIRED PROVIDED
NUMBER OF EXITS: 2 N/A (OPEN AIR)
TRAVEL DISTANCE:
EXIT ACCESS DESIGN REQUIREMENTS
MAX. ALLOWABLE ACTUAL MAX.
EXIT ACCESS TRAVEL DISTANCE (IBC TABLE 1017.2): 200 FT. 19 FT.
C
OMMON PATH OF TRAVEL (IBC TABLE 1006.2.1): 75 FT. N/A
D
EAD END CORRIDOR (IBC 1020.5): 20 FT. N/A
PLUMBING CALCULATIONS
NO CHANGE TO EXISTING PLUMBING FIXTURES OR OCCUPANCY COUNT
PUBLIC RESTROOMS ARE PROVIDED WITHIN THE DEVELOPMENT
OCCUPANCY CLASSIFICATION:
MIXED OCCUPANCY: Yes _______ No _______ Separation _______ Hr.
CONSTRUCTION TYPE: I-A I-B II-A II-B III-A III-B IV V-A V-B
MIXED CONSTRUCTION: Yes _______ No _______ Type ________________
SPRINKLERED: Yes _______ No _______
FIRE DISTRICT: Yes _______ No _______
BUILDING HEIGHT (MRH): Number of Stories: _______
MEZZANINE: Yes _______ No _______
HIGH RISE: Yes _______ No _______
X
X
X
X
X
X
14' - 4" 1
N/A
ASSEMBLY (A-2)
BUILDING DATA
POST OFFICE BOX 3978
BLUFFTON, SC 29910
PH: 843.815.2557
FX: 843.815.2547
WWW.COURTATKINS.COM
ISSUE
PROJECT INFO
SHEET TITLE
Date
Project No.
COPYRIGHT 2024 COURT ATKINS GROUP - THIS
DRAWING IS THE PROPERTY OF THE ARCHITECT
AND IS NOT TO BE REPRODUCED IN WHOLE OR IN
PART BY ANY MEANS OR METHOD WITHOUT THE
EXPRESS WRITTEN CONSENT OF THE ARCHITECT.
ANY UNAUTHORIZED REPRODUCTION OR REUSE
OF THESE DOCUMENTS WILL RESULT IN LEGAL
ACTION.
NOT
FOR C
ONSTRU
CTION
NOT
FOR C
ONSTRU
CTION
©
5/30/2025 12:09:41 PM
PERMIT DRAWINGS
SWEET AL'S CAFE PAVILION RENOVATION
1 NORTH BEACH DRIVE UNIT 1A
HILTON HEAD ISLAND, SOUTH CAROLINA 29928
05.30.2025
25-021
COVER, GENERAL NOTES AND
CODE SUMMARY
A0.0 SWEET AL'S CAFE PAVILION RENOVATION
1 NORTH BEACH DRIVE UNIT 1A
HILTON HEAD ISLAND, SOUTH CAROLINA 29928
SHT. # SHEET NAME
PERMIT DRAWINGS 05.30.2025
A0.0 COVER, GENERAL NOTES AND CODE SUMMARY X
A2.0 FLOOR PLAN, ELEVATIONS, SECTIONS AND DETAILS X
S1.0 STRUCTURAL NOTES X
S2.0 STRUCTURAL PLANS & DETAILS X
SHEET INDEX:
NO. REV. DATE DESCRIPTION
L
L
>
grCOURT
ATKINSGROUP
Page 12 of 22
ALTA/NSPS LAND TITLE SURVEY
Page 13 of 22
A. G.C. / SUB-CONTRACTORS SHALL BE RESPONSIBLE FOR ALL MEANS AND
METHODS OF COMPLETING THE SCOPE OF WORK.
B. SEE COVER PAGE FOR NOTES AND LIMITATIONS TO ARCHITECTURAL SCOPE
OF SERVICES.
C. SEE A0.2 FOR ANSI/ADA REQUIREMENTS.
D. GC/OWNER TO COORDINATE ALL IN-SLAB ELECTRICAL AND PLUMBING
REQUIREMENTS WITH APPROPRIATE SUBCONTRACTOR TRADES PRIOR TO
PLACING SLAB.
E. ADJUST TOP OF SLAB, WALL, AND ROOF BEARING PLATES AS REQUIRED FO R
C
HANGES IN STRUCTURAL MEMBER SIZES OR EXISTING SITE CONDITIONS.
F. STRUCTURAL ENGINEERING DOCUMENTS SUPERSEDE ARCHITECTURAL
DOCUMENTS AND SCHEDULES WITH REGARD TO SIZE OF STRUCTURAL
MEMBERS, PLACEMENT, AND CONNECTION DETAILS.
G. DIMENSIONS ARE TO THE EDGE OF FOUNDATION AND FRAMING, U.N.O.
DO NOT SCALE DRAWINGS. CONTACT ARCHITECT WITH ANY
DISCREPANCIES.
H. GC TO FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO DEMOLITION AND
NOTIFY ARCHITECT OF ANY DISCREPANCIES OR UNKNOWN CONDITIONS.
GENERAL FLOOR PLAN NOTES:
A2.0
3
6
A2.0
A2.05A2.0 4
7' - 4 1/4" 6' - 10"
14' - 8 1/2" 6' - 11"
V.I.F.
14' - 2 1/4"
V.I.F.
21' - 7 1/2"
7
A2.0
MAX TRAVEL DISTANCE = 19'
EXISTING DECK
TO REMAIN
MATCH EXISTING RAILING
NO CHANGE TO EXIST. STRUCT.
NOTE: GC TO PROTECT EXISTING
STRUCTURE, FINISHES & SYSTEMS
DURING DEMOLITION OF EXISTING
CANOPY AND CONSTRUCTION.
EXISTING LIGHT FIXTURES, FANS &
OTHER ASSOCIATED COMPONENTS
SHALL BE REMOVED AND STORED TO BE
REINSTALLED.
WOOD DECK
0' - 0" AFF
RIDGE HT.
14' - 4" AFF
ROOF BEARING (V.I.F.)
7' - 6" AFF
4"
12"
(MIN. 6'-8" V.I.F.)
6' - 8 3/4"
10"
12"
10"
12"
6X6 PT COLUMN, SEE STRUCT.
PT RAILING, TO MATCH EXIST.
2X8 PT WD RAFTERS, SEE STRUCT.
MTL. FLASHING
10' - 0"
7
A2.0
2X8 PT COLLAR TIE, SEE STRUCT.
3X10 PT BEAM, SEE STRUCT.
EXIST. SIGN TO
BE PRESERVED AND
REUSED
UPPER BEARING
9' - 10" AFF
3'-0" (V.I.F.) WOOD DECK
0' - 0" AFF
RIDGE HT.
14' - 4" AFF
6
A2.0
ROOF BEARING (V.I.F.)
7' - 6" AFF
22 GA. STANDING SEAM MTL. RF.
PT RAILING, TO MATCH EXIST
2X8 PT WD RAFTERS, SEE STRUCT.
EXIST. RF. TO REMAIN
UPPER BEARING
9' - 10" AFF
WOOD DECK
0' - 0" AFF
RIDGE HT.
14' - 4" AFF
6
A2.0
ROOF BEARING (V.I.F.)
7' - 6" AFF
22 GA. STANDING SEAM MTL. ROOF
PT RAILING, TO MATCH EXIST
2X8 PT WD RAFTERS, SEE STRUCT.
EXIST. RF. TO REMAIN
UPPER BEARING
9' - 10" AFF
A2.0
3
6
A2.0
A2.05A2.0 4 10" / 12" 10" / 12" 4" / 12"
22 GA. STANDING SEAM MTL. ROOF
7
A2.0
V.I.F.
10"
3"
V.I.F.
10"
EXIST. RF. TO REMAIN
NOTE: PAVILION ROOF TO ALIGN WITH EXIST
ROOF., WHILE MAINTAINING MIN. 6'-8"
CLEARANCE UNDER BEAM.
TRANSITION PER MANUF. RECCOMEND.
@ ASPHALT TO STANDING SEAM
ROOF TRANSITION
WOOD DECK
0' - 0" AFF
RIDGE HT.
14' - 4" AFF
ROOF BEARING (V.I.F.)
7' - 6" AFF
A2.0
12
A2.0
11
A2.0
10
7
A2.0
2X8 PT WD RAFTERS, SEE STRUCT.
2X8 PT COLLAR TIE, SEE STRUCT.
PT BEAMS, SEE STRUCT.
2X BLOCKING
2X10 RIDGE BEAM, SEE STRUCT.
UPPER BEARING
9' - 10" AFF
10"
12"
10"
12"
4"
12"
REF. 11/S2.0
FOR HIGH / LOW
BEARING DETAIL
ROOF BEARING (V.I.F.)
7' - 6" AFF
V.I.F.
10"
4"
12"
22 GA STANDING SEAM MTL. RF.
2X6 T&G DECKING, SEE STRUCT.
HIGH TEMP. ICE & WATER SHIELD
CLIP, SEE STRUCT.
ATTACHMENT, SEE STRUCT.
2X BLOCKING, SEE STRUCT.
MTL. RF. FLASHING
PT RAFTERS, SEE STRUCT.
PT BEAMS, SEE STRUCT.
PT COLUMN, SEE STRUCT.
ROOF BEARING (V.I.F.)
7' - 6" AFF
10"
12"
22 GA STANDING SEAM MTL. RF.
2X6 T&G DECKING, SEE STRUCT.
HIGH TEMP. ICE & WATER SHIELD
CLIP, SEE STRUCT.
ATTACHMENT, SEE STRUCT.
2X BLOCKING, SEE STRUCT.
MTL. RF. FLASHING
PT RAFTERS, SEE STRUCT.
PT BEAMS, SEE STRUCT.
PT COLUMN, SEE STRUCT.
V.I.F.
10"
WOOD DECK
0' - 0" AFF
6X6 PT COLUMN, BEYOND
4X4 PT WD POST W/ CAP, TO MATCH. EXIST.
PT WD RAILING, TO MATCH. EXIST
WD DECK, EXIST. TO REMAIN
EMBEDDED POST FOUNDATION,
BEYOND, SEE STRUCT.
WOOD DECK
0' - 0" AFF
RIDGE HT.
14' - 4" AFF
6
A2.0
ROOF BEARING (V.I.F.)
7' - 6" AFF
EXISTING BUILDING TO REMAIN
3X8 PT RAFTER AT END,
SEE STRUCT.
3X8 PT RAFTER AT END, SEE STRUCT.
2X8 PT COLLAR TIE, SEE STRUCT.
2X6 PT T&G DECKIING
3"
PT BEAM, SEE STRUCT.
PT RAILING, TO MATCH EXIST.
6X6 PT COLUMN
UPPER BEARING
9' - 10" AFF
POST OFFICE BOX 3978
BLUFFTON, SC 29910
PH: 843.815.2557
FX: 843.815.2547
WWW.COURTATKINS.COM
ISSUE
PROJECT INFO
SHEET TITLE
Date
Project No.
COPYRIGHT 2024 COURT ATKINS GROUP - THIS
DRAWING IS THE PROPERTY OF THE ARCHITECT
AND IS NOT TO BE REPRODUCED IN WHOLE OR IN
PART BY ANY MEANS OR METHOD WITHOUT THE
EXPRESS WRITTEN CONSENT OF THE ARCHITECT.
ANY UNAUTHORIZED REPRODUCTION OR REUSE
OF THESE DOCUMENTS WILL RESULT IN LEGAL
ACTION.
NOT
FOR C
ONSTRU
CTION
NOT
FOR C
ONSTRU
CTION
©
5/30/2025 12:09:44 PM
05.30.2025
25-021
FLOOR PLAN, ELEVATIONS,
SECTIONS AND DETAILS
A2.0 SWEET AL'S CAFE PAVILION RENOVATION
1 NORTH BEACH DRIVE UNIT 1A
HILTON HEAD ISLAND, SOUTH CAROLINA 29928
1/4" = 1'-0"A2.0
1 FLOOR PLAN
1/4" = 1'-0"A2.0
3 FRONT ELEVATION
1/4" = 1'-0"A2.0
4 LEFT ELEVATION
1/4" = 1'-0"A2.0
5 RIGHT ELEVATION
1/4" = 1'-0"A2.0
2 ROOF PLAN
A2.0
8 PERSPECTIVE A
1/4" = 1'-0"A2.0
6 BUILDING SECTION A
NO. REV. DATE DESCRIPTION
A2.0
9 PERSPECTIVE B
1" = 1'-0"A2.0
12 3/12 OVERHANG DETAIL
1" = 1'-0"A2.0
11 10/12 OVERHANG DETAIL
1" = 1'-0"A2.0
10 RAILING DETAIL
1/4" = 1'-0"A2.0
7 BUILDING SECTION B
err,ow "Pe,s° 6f......5%se" "·.%%gs cour 'zn: art :;-rw o :-Ek:ARCHITECTS, NC.: S
:BUFTON, SC ;0001g ¢Asi· l. ,%· ·¢;sp.<":S?so mg2""Pp%
grCOURT
ATKINSGROUP
-------4
0
0
-----$-
11
,
¥7°][ 7]
%9±EA
0
l
e
L
0
,
II II
II II
II II
1111
1111
rnnr= = n
j
>
0
=
I=
_L - - -
f
1,ee
)t
t
IT
II
II
0
« } I
M
II II
I
1111 11 II
II II
1
1111 II II
- -- 1111-
-- -! - -- -- -- -- tt11-
- - -- --n It
-- _J
Ill l ±» IT
7i
0
)•
.----4
II I
5
- - :s::J._
4-------4
0
+ =nat•1111
i
0
0
)0
nu ll
7177 1
[Ill__._- l,kl=et
]
--------4
j 9
--------------------------------------$-
1/ ~ ~/'-,_~--r-
$./ mo- is ii
0 0 0 0
Page 14 of 22
EXTENT OF WORK
METAL ROOF
SENTRICALD - CLASSIC GREEN, TO MATCH EXIST. DEVELOPMENT
COLUMNS, BEAMS, RAFTERS & RAILINGS
PRESSURE TREATED WOOD
COURT ATKINS GROUP 32 BRUIN ROAD, BLUFFTON, SC 29910 +1 843 815 2557 RESIDENTIAL | COMMERCIAL | INTERIORS
© COPYRIGHT 2024 COURT ATKINS GROUP - THIS DRAWING IS THE PROPERTY OF THE ARCHITECT AND IS NOT TO BE REPRODUCED IN WHOLE OR IN PART BY ANY MEANS OR METHOD WITHOUTTHE EXPRESS WRITTEN CONSENT OF THE ARCHITECT. ANY UNAUTHORIZED REPRODUCTION OR REUSE OF THESE DOCUMENTS WILL RESULT IN LEGAL
ACTION.
SWEET AL'S CAFE PAVILION RENOVATION
03.10.2026
I
COURT AIKINSg9 Gou
Page 15 of 22
NOTE: THE PURPOSE OF THIS PROJECT AS WE UNDERSTAND IT IS TO REPLACE AN EXISTING CANVAS &
METAL ROOF STRUCTURE INSTALLED AT THE FRONT OF AN EXISTING RESTAURANT TO COVER A DECK WITH
SITTING AREAS. THE REPLACEMENT STRUCTURE HAS BEEN DESIGNED IN ACCORDANCE WITH THE CURRENT
CODES AS LISTED ON THIS SHEET. THE DESIGN FOR THIS STRUCTURE UTILIZES THE NEW ELEMENTS TO
SUPPORT ALL LOADINGS AND DOES NOT TRANSFER ANY LOADING BACK TO THE EXISTING STRUCTURE.
THIS PROPOSED SCOPE OF THIS PROJECT DOES NOT REDUCE THE CAPACITY OR INCREASE THE APPLIED
LOADING TO THE EXISTING BUILDING, THEREFORE CONSIDERATION OF THIS STRUCTURE HAS NOT BEEN
INCLUDED IN OUR WORK.
GENERAL REQUIREMENTS
1. WHERE A SECTION OR DETAIL IS SHOWN FOR ONE CONDITION, IT SHALL APPLY TO ALL SIMILAR CONDITIONS.
2. COORDINATE ALL LIMITS AND DEPTHS OF DEPRESSIONS FOR FLOOR FINISHES WITH ARCHITECTURAL DRAWINGS AND
SCHEDULES. LIMITS SHOWN ON STRUCTURAL DRAWINGS ARE SCHEMATIC.
3. THE DESIGN ADEQUACY AND SAFETY OF ERECTION BRACING, SHORING, TEMPORARY SUPPORTS, ETC. SHALL BE THE
SOLE RESPONSIBILITY OF THE CONTRACTOR.
4. DO NOT SCALE DRAWINGS. FOLLOW DIMENSIONS SHOWN ON PLANS.
5. CONTRACTOR SHALL COORDINATE AND VERIFY ALL DIMENSIONS AND ELEVATIONS SHOWN HEREIN WITH
ARCHITECTURAL PLANS, SECTIONS, AND DETAILS PRIOR TO CONSTRUCTION OR MATERIAL PURCHASE AND SHALL
NOTIFY ARCHITECT OR ENGINEER IN WRITING OF DISCREPANCIES. SEE ARCHITECTURAL DRAWINGS FOR ALL
DIMENSIONS AND ELEVATIONS NOT SHOWN HEREIN.
6. DIMENSIONS INDICATED RELATIVE TO AN EXISTING STRUCTURE ARE APPROXIMATE AND SHALL BE FIELD VERIFIED BY
THE CONTRACTOR PRIOR TO CONSTRUCTION OR MATERIALS PURCHASE. CONTRACTOR SHALL NOTIFY ARCHITECT OR
ENGINEER IN WRITING OF DISCREPANCIES.
7. SPECIFIED ANCHOR SYSTEMS SHALL BE INSTALLED IN STRICT ACCORDANCE WITH MANUFACTURER'S WRITTEN
INSTRUCTIONS. SPECIAL ATTENTION SHALL BE GIVEN TO THE DRILLING, CLEANING, AND PREPARATION OF HOLES.
WHERE ADHESIVE ANCHORS ARE SHOWN, SPECIAL ATTENTION SHALL BE GIVEN TO THE REQUIRED MIXING,
APPLICATION, AND CURING TIME OF ADHESIVE TYPE SPECIFIED.
STRUCTURAL NOTES
PLYWOOD / GYP. BOARD SHEATHING
1. ALL PLYWOOD CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE AMERICAN PLYWOOD ASSOCIATION (APA) SPECIFICATIONS.
2. ALL ROOF PANEL SHEATHING SHALL BE PER PLAN. SUITABLE EDGE SUPPORT SHALL BE PROVIDED BY THE USE OF PANEL CLIPS OR BLOCKING
BETWEEN FRAMING.
3. INSTALL ALL PLYWOOD SHEATHING AT ROOF WITH THE LONG DIMENSIONS OF THE PANEL ACROSS SUPPORTS AND WITH PANEL CONTINUOUS
OVER TWO OR MORE SPANS. STAGGER PANEL END JOINTS. ALLOW 1/8" SPACING AT PANEL ENDS AND EDGES UNLESS OTHERWISE
RECOMMENDED BY THE SHEATHING MANUFACTURER.
4. ALL NAILS SHALL NOT BE OVERDRIVEN.
5. PROVIDE BLOCKING AT UNSUPPORTED PANEL EDGES AS FOLLOWS:
ROOFS - ONLY WHERE INDICATED ON PLAN
6. ALL PLYWOOD AND SHEATHING SHALL BE APA RATED, BEAR THE STAMP OF AN APPROVED TESTING AGENCY, AND SHALL BE FABRICATED
WITH EXTERIOR GLUE. NAILS AT ABUTTING PLYWOOD EDGES MUST PENETRATE THE SAME PIECE OF FRAMING OR BLOCKING.
7. PERIMETER OF ANY OPENINGS SHALL BE FASTENED AS BOUNDARY NAILING.
8. OPENINGS WITH A DIMENSION PERPENDICULAR TO THE JOISTS GREATER THAN 4'-0" SHALL BE BLOCKED BEYOND THE HEADERS, AND METAL
TIES NOT LESS THAN 16 GAGE BY 112" WIDE WITH (8)-16d COMMON NAILS ON EACH SIDE OF THE HEADER-JOIST INTERSECTION SHALL BE
PROVIDED.
FOUNDATIONS
1. FOUNDATIONS HAVE BEEN DESIGNED FOR 1,500 PSF MINIMUM ALLOWABLE SOIL BEARING PRESSURE.
2. REMOVE ALL WATER SOFTENED SOILS FROM FOOTING EXCAVATIONS PRIOR TO PLACING CONCRETE. FILL REMAINING
VOIDS WITH ADDITIONAL CONCRETE.
3. PROVIDE 1/2" EXPANSION JOINT FILLER AROUND PERIMETER OF SLABS WHERE THEY ABUT VERTICAL SURFACES AND AT
COLUMN ISOLATION JOINTS AS DETAILED.
STRUCTURAL DESIGN CRITERIA
DIMENSIONAL LUMBER FRAMING
1. ALL STRUCTURAL LUMBER DESIGN SHALL CONFORM TO THE REQUIREMENTS OF THE NATIONAL DESIGNS SPECIFICATION FOR WOOD
CONSTRUCTION (NDS-2018).
2. LOCATION, NUMBER, AND DIMENSIONS OF FRAMING MEMBERS SHOW GENERAL ARRANGEMENT ONLY. ACTUAL SPANS, SPACING, ETC. SHALL BE
DETERMINED FROM ARCHITECTURAL DETAILS.
3. SEE ARCHITECTURAL PLANS AND DETAILS FOR EDGE SECTIONS, HEADER AND LINTEL LOCATIONS, AND ALL NON-STRUCTURAL FRAMING AND
TRIM.
4. ALL WOOD FRAMING MATERIAL SHALL BE SURFACED DRY AND USED AT 19% MAXIMUM MOISTURE CONTENT. ALLOWABLE STRESS
REQUIREMENTS OF ALL MATERIALS SHALL BE IN ACCORDANCE WITH THE "SCHEDULE OF REQUIRED STRESS VALUES".
5. ALL STUD AND WALL FRAMING SHALL BE NO. 2 GRADE SOUTHERN YELLOW PINE (SYP). "STUD" GRADE MATERIAL IS STRICTLY PROHIBITED
FROM USE.
6. ALL JOIST, RAFTER & MISC. FRAMING SHALL BE NO. 2 GRADE, SOUTHERN YELLOW PINE. PROVIDE FULL-DEPTH BLOCKING AT ENDS. PROVIDE
FULL-DEPTH (OR METAL) BRIDGING AT MIDSPAN AND AT A MAXIMUM SPACING OF 8'-0" O.C. IN BETWEEN.
7. ALL LUMBER EXPOSED TO EXTERIOR ENVIRONMENT OR IN CONTACT WITH MASONRY OR CONCRETE SHALL BE PRESSURE TREATED TO A
MINIMUM RETENTION OF 0.25 lbs. OF ACQ PER CUBIC FOOT OF WOOD, AND EACH PIECE SHALL BEAR THE THIRD PARTY QUALITY MARK, "ABOVE
GRADE USE". ALL LUMBER IN CONTACT WITH THE GROUND SHALL BE PRESSURE TREATED TO A MINIMUM RETENTION OF 0.40 lbs. OF ACQ PER
CUBIC FOOT OF WOOD, AND EACH PIECE SHALL BEAR THE THIRD PARTY QUALITY MARK, "GROUND CONTACT USE". REFERENCE STANDARD
AWPA C2 AND ASTM D1760 FOR PRESSURE TREATMENT OF TIMBER PRODUCTS.
8. WHERE POSSIBLE ALL CUTS AND HOLES SHOULD BE COMPLETED BEFORE TREATMENT. CUTS AND HOLES DUE TO ON-SITE FABRICATION SHALL
BE BRUSHED WITH 2 COATS OF COPPER NAPHTHENATE SOLUTION CONTAINING A MINIMUM OF 2% METALLIC COPPER IN SOLUTION (PER AWPS
STD. M4).
9. THE CONTRACTOR SHALL CAREFULLY SELECT LUMBER TO BE USED IN LOAD BEARING APPLICATIONS. THE LENGTH OF SPLIT ON THE WIDE FACE
OF 2" NOMINAL LOAD BEARING FRAMING SHALL BE LIMITED TO LESS THAN ½ OF THE WIDE FACE DIMENSION. THE LENGTH OF SPLIT ON THE
WIDE FACE OF 3" (NOMINAL) AND THICKER LUMBER SHALL BE LIMITED TO HALF OF THE NARROW FACE DIMENSIONS.
10. ALL WOOD JOISTS AND HEADERS WHICH FRAME INTO BEAMS SHALL BE SUPPORTED BY SIMPSON LUS HANGERS WITH THE SAME WIDTH AND
DEPTH OF THE MEMBER, U.N.O. USE HANGERS WITH CONCEALED FLANGES WHERE THE CONNECTOR CANNOT BE HIDDEN BY WOOD TRIM OR
THE SUPPORT MEMBER IS WIDER THAN THE STANDARD FLANGE.
11. PROVIDE NAILING PATTERN IN COMPLIANCE WITH IBC RECOMMENDED FASTENING SCHEDULE.
12. LOAD BEARING STUD WALLS SHALL BE CONTINUOUSLY BRIDGED AT MID-HEIGHT AND UNSUPPORTED PLYWOOD WALL SHEATHING JOINTS WITH
SOLID WOOD BLOCKING, U.N.O.
13. NO CUTS, HOLES, OR COPES IN STRUCTURAL WOOD FRAMING SHALL BE PERMITTED WITHOUT PRIOR REVIEW AND APPROVAL BY THE
STRUCTURAL ENGINEER AND ARCHITECT.
14. PROVIDE FULL-DEPTH BLOCKING AT ENDS OF RAFTERS AND JOISTS. PROVIDE FULL-DEPTH (OR METAL) BRIDGING AT MIDSPAN AND AT A
MAXIMUM SPACING OF 8'-0" O.C. IN BETWEEN.
15. STRUCTURAL STEEL PLATE CONNECTORS SHALL CONFORM TO ASTM A36 SPECIFICATIONS AND BE ¼" THICK UNLESS OTHERWISE INDICATED.
BOLTS CONNECTING WOOD MEMBERS SHALL BE PER ASTM A307 AND BE 34" DIAMETER UNLESS OTHERWISE INDICATED. PROVIDE WASHERS
FOR ALL BOLT HEADS AND NUTS IN CONTACT WITH WOOD SURFACES.
16. BOLT HOLES SHALL BE CAREFULLY CENTERED AND DRILLED NOT MORE THAN 1/16" LARGER THAN THE BOLT DIAMETER. BOLTED CONNECTIONS
SHALL BE SNUG TIGHT BUT NOT TO THE EXTENT OF CRUSHING WOOD UNDER WASHERS.
17. HOLES AND NOTCHES DRILLED OR CUT INTO WOOD FRAMING SHALL NOT EXCEED THE REQUIREMENTS OF IBC, SECTION 23.
18. ALL PLATES, ANCHORS, NAILS, BOLTS, NUTS, WASHERS, AND OTHER MISCELLANEOUS HARDWARE INSTALLED IN PRESSURE TREATED LUMBER,
SHALL BE HOT DIP GALVANIZED.
19. ADEQUATE BRACING SHALL BE PROVIDED UNTIL PERMANENT BRACING AND/OR DIAPHRAGMS ARE INSTALLED.
20. OVERLAP ALL TOP PLATES AT CORNERS.
21. JOINTS IN THE DOUBLE TOP PLATES OF WALLS SHALL BE OFFSET A MINIMUM LAP LENGTH OF 4'-0" & NAILED WITH NOT LESS THAN (15)-16d
FACE NAILS ON EACH SIDE OF THE JOINT.
22. ALL BEAMS SHALL HAVE LATERAL SUPPORT AT THE COMPRESSION EDGE AT A MAXIMUM OF 24" O.C. AND AT BEARING POINTS, WITH A
MINIMUM BEARING LENGTH OF 3 1/2".
23. PROVIDE DOUBLE JOISTS OR SOLID BLOCKING AT 24" O.C. UNDER ALL PARTITIONS AND TO SUPPORT CONCENTRATED LOADS FROM FRAMING
ABOVE UNLESS NOTED OTHERWISE.
24. PROVIDE DOUBLE HEADER BEAMS OF THE SAME SIZE AS JOISTS OR RAFTERS TO FRAME AROUND OPENINGS IN PLYWOOD DECK UNLESS
OTHERWISE INDICATED.
25. PROVIDE DOUBLE LAYER PLYWOOD UNDER ALL CERAMIC OR STONE TILE FLOORS.
26. PROVIDE HEADERS, BRIDGING, CONNECTORS, BLOCKING, TRIMMERS, ETC. AS REQUIRED AND RECOMMENDED BY AITC TIMBER CONSTRUCTION
STANDARDS AND 2021 SCBC U.N.O.
27. WOOD FRAMING MATERIALS:
A. ALL DIMENSIONAL LUMBER SHALL BE #2 SYP KD OR BETTER AND PROVIDE NOT LESS THAN THE FOLLOWING ALLOWABLE
STRESSES:
Fb = 1,000 PSI
Ft = 600 PSI
E = 1,400,000 PSI
Fc = 1,400 PSI
Fcp = 565 PSI
B. SHEATHING:
WALLS..............................................APA RATED SHEATHING, EXPOSURE 1 OR EXTERIOR;
ROOF................................................APA RATED SHEATHING, EXPOSURE1, 2, OR EXTERIOR;
FLOOR..............................................APA RATED STURD-I-FLOOR;
C. ALL BOLTS SHALL BE ASTM A307 WITH WASHERS, GALVANIZED;
D. NAILS IN ACCORDANCE WITH MINIMUM NAILING REQUIREMENTS OF SCBC EXCEPT WHERE NOTED IN DETAILS OR SPECIFICATIONS.
ALL NAILS TO BE GALVANIZED.
CAST-IN-PLACE REINFORCED CONCRETE
1. THE FOLLOWING ACI STANDARDS (LATEST EDITION) APPLY:
A. ACI 318 - CODE
B. ACI 315 - DETAILING
C. ACI 301 - SPECIFICATIONS
D. ACI 304 - PLACING
E. ACI 347 - FORMWORK
F. ACI 211.1 - MIX PROPORTIONING
G. ACI 305 - HOT WEATHER CONCRETING
H. ACI 306 - COLD WEATHER CONCRETING
2. ALL CONCRETE SHALL BE NORMAL WEIGHT CONCRETE (145 PCF) WITH MIXES MEETING THE FOLLOWING CRITERIA:
STRUCTURAL ELEMENT28 DAY COMPRESSIVE STRENGTH
FOOTINGS, GRADE BEAMS &
FOUNDATION WALLS3,000 PSI
SLAB ON GRADE3,000 PSI
ELEVATED SLABS & BEAMS4,000 PSI
COLUMNS4,000 PSI
3.SLUMP SHALL NOT EXCEED 5". SLUMP TESTS SHALL BE PERFORMED ON EACH TRUCK LOAD AND CONFORM TO ASTM C143.
a
a
GABLE FREE
a = 3.6 FT
WIND PRESSURES (PSF)
COMPONENTS & CLADDING
2
a
a
1
3
ROOF: 7 TO 45
DEGREES
ZONEAREA(SF)+P -PASD
+PASD -P
11019.6 49.2 16.0 29.52
120 19.6 49.2 16.029.52
150 19.6 49.2 16.029.52
1100 19.6 49.2 16.029.52
210 31.4 73.918.84 44.34
220 31.4 73.9 18.8444.34
250 31.4 73.918.8444.34
210019.649.2 16.029.52
310 39.3 98.523.58 59.1
320 31.4 73.9 18.8444.34
350 31.4 73.9 18.8444.34
3100 19.6 49.2 16.029.52
1. BUILDING CODE:
2021 SOUTH CAROLINA BUILDING CODE (SCBC)
2. GRAVITY LOADS (ASCE 7-16):
DISTRIBUTED
ROOF LL = 20 PSF
DL = 20 PSF
COLLATERAL LOAD CL = 5 PSF
3. WIND LOADS (ASCE 7-16/ 2021 SCBC):
BASIC DESIGN WIND SPEED, V = 145mph
ALLOWABLE STRESS DESIGN WIND SPEED, VASD = 112mph
RISK CATEGORY II
WIND EXPOSURE C
INTERNAL PRESSURE COEFFICIENT, GC^pi = ±0.00
4. SEISMIC LOADS (ASCE 7-16/ 2021 SCBC):
RISK CATEGORY II
SEISMIC IMPORTANCE FACTOR, IE = 1.00
MAPPED SPECTRAL RESPONSE ACCELERATION PARAMETERS:
SS = 0.55g; S1 = 0.14g
SITE CLASS D
DESIGN SPECTRAL RESPONSE ACCELERATION PARAMETERS:
SDS = 0.38g; SD1 = 0.20g
SEISMIC DESIGN CATEGORY D
BASIC SEISMIC FORCE-RESISTING SYSTEM:
TIMBER CANTILEVERED COLUMN SYSTEM
DESIGN BASE SHEAR:
V = CsW
W = EFFECTIVE SEISMIC MASS
SEISMIC RESPONSE COEFFICIENT, CS = 0.25
RESPONSE MODIFICATION FACTOR, R = 16.5
ANALYSIS PROCEDURE:
EQUIVALENT LATERAL FORCE METHOD
5. SNOW LOAD (ASCE 7-16):
GROUND SNOW LOAD Pg = 0 PSF
6. RAIN LOAD DATA 2021 SCBC:
RAIN INTENSITY i = 4.5 in/hr
STRUCTURAL DESIGN CONSULTANTS
PROJECT No. 25-412
COPYRIGHT 2025 COURT ATKINS
GROUP - THIS DRAWING IS THE PROPERTY
OF THE ARCHITECT AND IS NOT TO BE
REPRODUCED IN WHOLE OR IN PART BY ANY
MEANS OR METHOD WITHOUT THE EXPRESS
WRITTEN CONSENT OF THE ARCHITECT. ANY
UNAUTHORIZED REPRODUCTION OR REUSE
OF THESE DOCUMENTS WILL RESULT IN
LEGAL ACTION.
©
NO.REV. DATEDESCRIPTION
No. 7089
SOUTH
CAROLINA
SHEARLOCK
ENGINEERING,
LLC
CE
NOITA
RI TFICATE
ZIRO
OF
HT
AU
05.30.2025
STRUCTURAL
NOTES
S1.0
I
I
PSHEARLOCK•ENGINEERING
COURT
ATKINSGROUP
POSTOFFICEBOX3978
BLUFFTON,SC29910
PH:843.815.2557
FX:843.815.2547
WWW.COURTATKINS.COM
CX)
N0 z0
0N
<(
_Jz
>I0 <r-
«3 0..-
w+-,I .b LLzo <((I) LI
O>- -
oz0-z O<( -OI I JO- 1H-< <(Lu!
H>00uj
rT JO'z LIzg5 zLuO;z_ 0-T
pt+u,,'ta,I,, s°2 -- -- -- -- -- -- -- -- --
PROJECTINFO
Date
05.30.2025
ProjectNo.
24-021
ISSUE
SHEETTITLE
Page 16 of 22
- FOOTING MARK - SEE FOOTING SCHEDULE
- COLUMN MARK - SEE COLUMN SCHEDULE
GENERAL LEGEND
F1
C1
- COLUMN FOOTING
N/A F1
MARK W L T
FOOTING SCHEDULE
'A' BARS'B' BARS
4'-0" 1'-6"ØN/A
FRAMING NOTES:
1.ROOF SHEATHING: P.T. SYP #2 GRADE 2x6 T&G DECKING SPANNING
OVER (3) RAFTERS (MIN.) & FASTENED W/ (2) #12 WOOD SCREWS @
EACH RAFTER (16" O.C. MIN.)
P.T. 6x6 SOLID POSTC1
COLUMN SCHEDULE
COLUMN TYPEMARK
1
S2.0
FOUNDATION PLAN
SCALE: 1/4" - 1'-0"
F1
F1
F1
F1
F1
F1
F1
F1
F1
6'-10"7'-414"
14'-812"6'-11"
21'-712"
14'-214"
EXISTING BUILDING
TO REMAIN
EXISTING ON GRADE DECK TO REMAIN EXCEPT
WHERE REMOVAL IS REQUIRED TO COMPLETE
NEW WORK. G.C. TO REPAIR TO MATCH
EXISTING CONDITION WHEN COMPLETE.
OFFSET FOOTING TO AVOID
EXISTING BUILDING FOUNDATION
WHILE MAINTAINING MINIMUM
CONCRETE COVERAGE PER
DETAIL. NOTIFY E.O.R. IF UNABLE
TO ACHIEVE INTENT BASED ON
SITE CONDITIONS
NOTE: COLUMN LOCATIONS ARE
APPROXIMATE & SHALL BE VERIFIED IN
FIELD TO AVOID EXISTING UTILITIES,
STRUCTURES & PLANTINGS. INTENT IS
TO MATCH EXISTING GEOMETRY.
2
S2.0
BEAM FRAMING PLAN
SCALE: 1/4" - 1'-0"
C1 C1
C1
P.T. 3x10
P.T. 3x10 (CONT.)
P.T. 3x10 (CONT.)
C1
C1
C1C1
C1
C1
P.T. 3x10 EACH SIDE
(CONT.) - HIGH @
SHED ROOF BEARING
P.T. 3x10 (CONT.)
P.T. 3x8 (CONT.)
P.T. 3x10
8
S2.0
EXISTING BUILDING
TO REMAIN
SIM.
NOTE: INTENT IS FOR BEAMS TO
ALIGN W/ EXISTING PLATE HEIGHT
OF BUILDING. VERIFY IN FIELD.
P.T. 3x10
LOCATE END BEAM @ FACE OF EXISTING
BUILDING, BUT DO NOT CONNECT EXCEPT
AS REQUIRED FOR FINISHES & FLASHING
REFER TO DETAIL 5/S300
FOR TYPICAL BEAM TO
COLUMN CONNECTION
P.T. 3x10
EXISTING RAILING
BELOW TO REMAIN
- U.N.O. BY ARCH.
5
S2.0
6
S2.0
11
S2.0
2x8 COLLAR TIES @ 16" O.C.
(BOTTOM EL. 10'-0" A.F.F.)
7
S2.0
P.T. 3x8 (CONT.) - LOW @
COMMON BEAM ELEVATION
P.T. 3x10 (CONT.) - LOW @
COMMON BEAM ELEVATION
10" / 12"10" / 12"4" / 12"
3
S2.0
ROOF FRAMING PLAN
SCALE: 1/4" - 1'-0"
EXISTING BUILDING
TO REMAIN
P.T. 3x8 END RAFTER
BOTH SIDES WITH OPEN
GABLE BELOW (TYP.)
COLUMN BELOW
SIM.
11
S2.0
OVERBUILD - SEE 9/S300
10
S2.0
P.T. 2x10 RIDGE BOARD
7
S2.0
5
S2.0
6
S2.0
9
S2.0
LOCATE END GABLE RAFTER @ FACE
OF EXISTING BUILDING, BUT DO NOT
CONNECT EXCEPT AS REQUIRED FOR
FINISHES & FLASHING
BEAM BELOW (TYP.)
2x8 @ 16" O.C.
2x8 @ 16" O.C.
2x8 @ 16" O.C.
4
S2.0
EMBEDDED POST FOUNDATION
NOT TO SCALE
4'-0" (MIN.)
COMPACTED SUBGRADE -
SEE STRUCTURAL NOTES 1'-6"Ø
SECTION A-A
A A
4" CLR. (MIN.)
3000psi CONCRETE
FOOTING
Ø1'-6"
MASONRY BRICK AT
BOTTOM OF FOOTING
GROUND CONTACT
RATED POST - SEE PLAN
4" CLR. (MIN.)
SLOPESLOPE
(2)-#5x12" BARS
THROUGH POST
TOP & BOTTOM
2x BLOCKING
(2) #12 3" WOOD SCREW
THROUGH BLOCKING INTO
EACH RAFTER
SIMPSON STRONG-TIE LS50 OR
EQUAL, AT EACH RAFTER
T&G DECKING - SEE
FRAMING NOTES
RAFTER - SEE PLAN
RAFTER - SEE PLAN
9
S2.0
DETAIL AT OVERBUILT SHED ROOF
NOT TO SCALE
8
S2.0
TYPICAL SIDELAP DETAIL
NOT TO SCALE
COLLAR TIE -
SEE PLAN
(8) 16d NAILS SIDE
LAPPED INTO RAFTER
T&G DECKING - SEE
FRAMING NOTES
ROOF FINISH -
SEE ARCH. PLAN
ROOF FINISH - SEE
ARCH. PLAN
10
S2.0
CONNECTION AT LVL RIDGE BEAM
NOT TO SCALE
(2)34"Ø (MIN.) HDG CARRIAGE
BOLTS THROUGH EACH BEAM & POST
SEE OVERBUILD DETAIL 9/S2.0 FOR
TYP. RAFTER CONDITION BEYOND
(2)34"Ø (MIN.) HDG
CARRIAGE BOLTS THROUGH
EACH BEAM & POST
11
S2.0
BEAM CONNECTION HIGH & LOW
NOT TO SCALE
BEAM - SEE PLAN
RAFTER - SEE PLAN
RAFTER - SEE PLAN
T&G DECKING - SEE FRAMING NOTES
RAFTER - SEE PLAN
RAFTER - SEE PLAN
T&G DECKING - SEE
FRAMING NOTES
SIMPSON STRONG-TIE
LRU28Z HANGER (TYP.)
RIDGE BOARD - SEE PLAN TIMBERLOK SCREW INTO
BEAM (2" MIN. PENETRATION)
5
S2.0
DETAIL AT BEAM SPLICE @ CORNER
NOT TO SCALE
RAFTERS - SEE PLAN
ROOF FINISH - SEE ARCH PLAN
COLUMN BEYOND - SEE PLAN
6
S2.0
DETAIL AT GABLE END
NOT TO SCALE
P.T. 3x8 END RAFTER
PER PLAN (TYP.)
RIDGE BEAM -
SEE PLAN
T&G DECKING - SEE FRAMING NOTES
ROOF FINISH -
SEE ARCH PLAN
FASTEN ALL RAFTERS TO
RIDGE W/ SLOPED FACE
MOUNT HANGER - NOT
SHOWN FOR CLARITY
PLATE
LINE
SIMPSON STRONG-TIE H2.5A
HURRICANE CLIP (OR EQUAL) AT EACH
RAFTER TO BEAM CONNECTION
'BIRDS-MOUTH' CUT AT EACH RAFTER
FOR FULL BEARING OVER BEAMS
NOTCH POST FOR 1" BEARING FOR
BEAMS SUPPORTING RAFTERS SECTION A-A
(2)34"Ø (MIN.) HDG
CARRIAGE BOLTS THROUGH
EACH BEAM AND POST
BEAM - SEE PLAN
COLUMN - SEE PLAN
BEAM BEYOND - SEE PLAN
BEAM EACH SIDE OF POST - SEE PLAN
(2)34"Ø (MIN.) HDG CARRIAGE
BOLTS THROUGH EACH BEAM,
POST, & @ BLOCKING
REF. ARCH. FOR
OVERHANG
DIMENSIONS &
FINISH GEOMETRY
RAFTERS - SEE PLAN
RIDGE BEAM -
SEE PLAN
T&G DECKING - SEE
FRAMING NOTES
ROOF FINISH -
SEE ARCH PLAN
FASTEN ALL RAFTERS TO
RIDGE W/ SLOPED FACE
MOUNT HANGER - NOT
SHOWN FOR CLARITY
REF. ARCH. FOR
OVERHANG
DIMENSIONS &
FINISH GEOMETRY
MATCH TOP OF ROOF TO
EXISTING STRUCTURE
TOP OF ROOF
7
S2.0
DETAIL AT GABLE END
NOT TO SCALE
P.T. 3x8 END RAFTER
PER PLAN (TYP.)
T&G DECKING - SEE
FRAMING NOTES
RAFTERS - SEE PLAN
EXISTING
STRUCTURE
TO REMAIN
FULL DEPTH BLOCKING BETWEEN ALL RAFTERS
BLOCKING BETWEEN PLYS
MATCHING GAP & DEPTH OF
MEMBERS @ 6'-0" O.C. (MAX.)
STRUCTURAL
PLANS &
DETAILS
S2.0
STRUCTURAL DESIGN CONSULTANTS
PROJECT No. 25-412
COPYRIGHT 2025 COURT ATKINS
GROUP - THIS DRAWING IS THE PROPERTY
OF THE ARCHITECT AND IS NOT TO BE
REPRODUCED IN WHOLE OR IN PART BY ANY
MEANS OR METHOD WITHOUT THE EXPRESS
WRITTEN CONSENT OF THE ARCHITECT. ANY
UNAUTHORIZED REPRODUCTION OR REUSE
OF THESE DOCUMENTS WILL RESULT IN
LEGAL ACTION.
©
NO. REV. DATEDESCRIPTION
No. 7089
SOUTH
CAROLINA
SHEARLOCK
ENGINEERING,
LLC
CE
NOITA
RI TFICATE
ZIRO
OF
HT
AU
05.30.2025
CX)
N0 z0
0N
<(
_Jz
>I0 <r-
«3 0..-
w+-,I .b LLzo <((I) LI
O>- -
oz0-z O<( -OI I JO- 1H-< <(Lu!
H>00uj
rT JO'z LIzg5 zLuO;z_ 0- -T
pt+u,,'ta,I,, s°2 -- -- -- -- -- -- -- -- --
POSTOFFICEBOX3978
BLUFFTON,SC29910
PH:843.815.2557
FX:843.815.2547
WWW.COURTATKINS.COM
PROJECTINFO
COURT
ATKINSGROUP
I
0t
ti
0
I
0
I
0
I
au-□
:
0
I '
4
,,B
7
ms,
I
I(
0
0
0
0
ProjectNo.
24-021
Date
05.30.2025
SHEETTITLE
ISSUE
J
0
r
000aHlSHEARLOCK
I:1ENGINEERING:.@ eee,
Page 17 of 22
Page 18 of 22
1
DDEESSIIGGNN TTEEAAMM//DDRRBB CCOOMMMMEENNTT SSHHEEEETT
TThhee ccoommmmeennttss bbeellooww aarree ssttaaffff rreeccoommmmeennddaattiioonnss ttoo tthhee DDeessiiggnn RReevviieeww BBooaarrdd ((DDRRBB))
aanndd ddoo NNOOTT ccoonnssttiittuuttee DDRRBB aapppprroovvaall oorr ddeenniiaall..
PROJECT NAME: 1 North Forest Beach Unit: A1 DRB-000266-2026
DATE: 03/25/2026 CATEGORY: Alteration
RECOMMENDATION: Approval Approval with Conditions Denial
APPLICATION MATERIAL
DRB REQUIREMENTS Complies
Yes
No
Not Applicable Comments or Conditions
Demolition Plan if needed
Existing Conditions match As-Built
Dimensioned Details and of Sections
Detail Illustrating Connection to Existing Structure
New Building Details Match Existing Building Details
ARCHITECTURAL DESIGN
DESIGN GUIDE/LMO CRITERIA Complies
Yes
No
Not Applicable Comments or Conditions
Structure is designed to be appropriate to the
neighborhood
Promotes pedestrian scale and circulation
Design is unobtrusive and set into the natural
environment
Utilizes natural materials and colors
Avoids distinctive vernacular styles
Design is appropriate for its use
All facades shall have equal design characteristics
Page 19 of 22
2
Avoids monotonous planes or unrelieved repetition
Has a strong roof form with enough variety to provide
visual interest
Overhangs are sufficient for the façade height.
Forms and details are sufficient to reduce the mass of the
structure
Human scale is achieved by the use of proper proportions
and architectural elements
Utilizes a variety of materials, textures and colors
Incorporates wood or wood simulating materials
Windows are in proportion to the facade
Details are clean, simple and appropriate while avoiding
excessive ornamentation
Utilities and equipment are concealed from view
Decorative lighting is limited and low wattage and adds
to the visual character
Accessory elements are designed to coordinate with the
primary structure
LANDSCAPE DESIGN
DESIGN GUIDE/LMO CRITERIA Complies
Yes
No
Not Applicable Comments or Conditions
Treats the Landscape as a major element of the project Provide additional plantings.
Provides Landscaping of a scope and size that is in
proportion to the scale of the development
Landscape is designed so that it may be maintained in
its natural shape and size
Provide a Landscape Plan.
Preserves a variety of existing native trees and shrubs
Indicate how you are maintaining or enhancing the
existing landscaping at the left side of the entrance
and across the sidewalk.
Provides for a harmonious setting for the site’s
structures, parking areas or other construction
Location of existing trees and new trees provides
street buffers, mitigation for parking lots, and an
architectural complement that visually mitigates
between parking lots and building(s)
Shrubs are selected to complement the natural setting,
provide visual interest and screen less-desirable
elements of the project
A variety of species is selected for texture and color
Page 20 of 22
3
Provides overall order and continuity of the
Landscape plan
Native plants or plants that have historically been
prevalent on the Island are utilized
A variety of sizes is selected to create a “layered”
appearance for visual interest and a sense of depth
The location of existing mature trees is taken into
account in placement of shrubs so as not to damage
tree roots
Proper spacing and location for plants to reach their
mature size and natural shape while avoiding
excessive or unnatural pruning
Proposed groundcovers are evergreen species with
low maintenance needs
Large, grassed lawn areas encompassing a major
portion of the site are avoided
The adjacent development is taken into account in
determining the most appropriate buffer so as not to
depart too dramatically from the neighborhood
Ornamentals and Annuals are limited to entrances and
other focal points
NATURAL RESOURCE PROTECTION
DESIGN GUIDE/LMO CRITERIA Complies
Yes
No
Not Applicable Comments or Conditions
An effort has been made to preserve existing trees and
under story plants
Supplemental and replacement trees meet LMO
requirements for size, species and number
Wetlands if present are avoided and the required
buffers are maintained
Sand dunes if present are not disturbed
COMMENTS & CONDITIONS
Staff recommend approval of the Alteration submittal for 1 North Forest Beach Unit: A1, with the following conditions:
1. Landscape Plan required. The applicant shall provide a landscape plan indicating the existing landscaping adjacent to the structure and
demonstrating how these plantings will be maintained, relocated, or enhanced as part of the proposed alteration.
2. The Design Guide emphasizes that buildings should sit within the landscape, and landscaping should be maintained or enhanced during building
alterations.
3. The landscape plan shall include plant species, quantities, and locations to ensure that the building continues to be integra ted within the landscape.
Page 21 of 22
4
4. Any additional information as required by the Board.
Page 22 of 22
Source: Town of Hilton Head Island website. First collected Oct 17, 2026.