RecordWell Data

Design Review Board Meeting — Agenda Packet

Town of Hilton Head Island · Beaufort County · Design Review Board · meeting of Mar 11, 2026 · Agenda packets

Open the original document More from Town of Hilton Head Island

Text

Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.

Town of Hilton Head Island Design Review Board Meeting Wednesday, March 11, 2026, 2:30 PM 1 Town Center Court, Hilton Head Island, SC Conference Room Four The Design Review Board meeting will be held in person at Town Hall in Conference Room Four 1. Call to Order 2. Adoption of the Agenda 3. Approval of the Minutes a. Regular Meeting Minutes of February 25, 2026 4. Unfinished Business a. DRB-000212-2026 - 840 William Hilton Parkway - The Atrium Building - Final 5. New Business a. DRB-000215-2026 - 862 William Hilton Parkway - Alteration 6. Public Comment - Non Agenda Items 7. Board Business a. Discussion of proposed updates to the existing Design Guide and direction on advancing the updated Design Guide. 8. Staff Reports 9. Adjournment FOIA Compliance: Public notification of this meeting has been published, posted, and distributed in compliance with the South Carolina Freedom of Information Act and the requirements of the Town of Hilton Head Island. In accordance with the requirements of Title II of the Americans with Disabilities Act of 1990 ("ADA"), the Town of Hilton Head Island will not discriminate against qualified individuals with disabilities on the basis of disability in its services, programs, or Page 1 of 68 activities. Auditory accommodations are available. Any person requiring further accommodation should contact the Town of Hilton Head Island ADA Coordinator as soon as possible but no later than 48 hours before the scheduled event. Municipal Association of South Carolina (MASC) Civility Pledge: “I pledge to build a stronger and more prosperous community by advocating for civil engagement, respecting others and their viewpoints, and finding solutions for the betterment of my city or town.” Page 2 of 68 Town of Hilton Head Island Design Review Board Meeting Minutes 2/25/2026 Page | 1 Town of Hilton Head Island DESIGN REVIEW BOARD MEETING Wednesday, February 25, 2026, 2:30 PM Minutes 1. Call to Order Chair Carstens called the meeting to order at 2:30 p.m. In attendance: Megan Fitzpatrick, Todd Theodore, Judd Carstens, Annette Lippert, Tom Parker, Patricia Pastor, and Cathy Foss. 2. Adoption of the Agenda Mr. Theodore made a motion to adopt the agenda. Ms. Pastor seconded. The motion passed unanimously. 3. Approval of the Minutes a. Regular Meeting Minutes of February 11, 2026 Mr. Parker made a motion to approve the minutes of February 11, 2026. Ms. Foss seconded. The motion passed unanimously. 4. Unfinished Business 5. New Business 6. Public Comment - Non Agenda Items 7. Board Business a. Discussion of proposed updates to the existing Design Guide and direction on advancing the updated Design Guide Principal Planner Melissa Paul-leto presented the Board's comments regarding multiple elements of the Design Guide. Board members discussed their concerns and provided additional clarification and elaboration on their feedback. The discussion on the Design Guide will continue at the March 11, 2026, meeting. 8. Staff Reports 9. Adjournment The meeting was adjourned at 5:03 p.m. Page 3 of 68 Page 4 of 68 Last Revised 01/21/15 1 Applicant/Agent Name: ______________________________ Company: _____________________________________ Mailing Address: ___________________________________ City: _________________ State: ______ Zip: ________ Telephone: _ __________________ Fax: _________________ E-mail: _______________________________________ Project Name: _________________________ Project Address: _____________________________________ Parcel N umber [PIN]: R_552 015 000 0269 0000_ __ Zoning District: ______________ Overlay District(s): ___________________________________ Town of Hilton Head Island Community Development Department One Town Center Court Hilton Head Island, SC 29928 Phone: 843-341-4757 Fax: 843-842-8908 www.hiltonheadislandsc.gov CORRIDOR REVIEW, MAJOR DESIGN REVIEW BOARD (DRB) SUBMITTAL REQUIREMENTS Digital Submissions may be accepted via e-mail by calling 843-341-4757. Project Category: _____ Concept Approval – Proposed Development _____ Alteration/Addition _____ Final Approval – Proposed Development _____ Sign FOR OFFICIAL USE ONLY Date Received: _____________ Accepted by: ______________ DRB #:___________________ Meeting Date: _____________ Submittal Requirements for All projects: _____ Private Architectural Review Board (ARB) Notice of Action (if applicable): When a project is within the jurisdiction of an ARB, the applicant shall submit such ARB’s written notice of action per LMO Section 16- 2-103.I.4.b.iii.01. Submitting an application to the ARB to meet this requirement is the responsibility of the applicant. _____ Filing Fee: Concept Approval-Proposed Development $175, Final Approval – Proposed Development $175, Alterations/Additions $100, Signs $25; cash or check made payable to the Town of Hilton Head Island. Additional Submittal Requirements: Concept Approval – Proposed Development _____ A survey (1"=30' minimum scale) of property lines, existing topography and the location of trees meeting the tree protection regulations of Sec. 16-6-104.C.2, and if applicable, location of bordering streets, marshes and beaches. _____ A site analysis study to include specimen trees, access, significant topography, wetlands, buffers, setbacks, views, orientation and other site features that may influence design. _____ A draft written narrative describing the design intent of the project, its goals and objectives and how it reflects the site analysis results. _____ Context photographs of neighboring uses and architectural styles. _____ Conceptual site plan (to scale) showing proposed location of new structures, parking areas and landscaping. _____ Conceptual sketches of primary exterior elevations showing architectural character of the proposed development, materials, colors, shadow lines and landscaping. 7 Greenwood Dr. Timothy C Probst 10 Palmetto Business Park Suite 201 843-785-5171 The Atrium Building 520 011 000 132A 0000 Light Commerical X X X X X X X X PDG Architects Hilton Head Island SC Tim@PDG-Architects.com 840 WHP 29928 Page 5 of 68 Last Revised 01/21/15 2 Note: All application items must be received by the deadline date in order to be reviewed by the DRB per LMO Appendix D: D-23. A representative for each agenda item is strongly encouraged to attend the meeting. Are there recorded private covenants and/or restrictions that are contrary to, conflict with, or prohibit the proposed request? If yes, a copy of the private covenants and/or restrictions must be submitted with this application. YES NO To the best of my knowledge, the information on this application and all additional docum entation is true, factual, and complete. I hereby agree to abide by all c onditions of any approvals granted by the Town of Hilton Head Island. I understand that such conditions shall a pply to the subject propert y only and are a right or obligation transferable by sale. I further understand that in the event of a State of Em ergency due to a Disaster, the review and approval times set forth in the Land Management Ordinance may be suspended. SIGNATURE DATE Additional Submittal Requirements: Final Approval – Proposed Development _____ A final written narrative describing how the project conforms with the conceptual approval and design review guidelines of Sec. 16-3-106.F.3. _____ Final site development plan meeting the requirements of Appendix D: D-6.F. _____ Final site lighting and landscaping plans meeting the requirements of Appendix D: D-6.H and D-6.I. _____ Final floor plans and elevation drawings (1/8"=1'-0" minimum scale) showing exterior building materials and colors with architectural sections and details to adequately describe the project. _____ A color board (11"x17" maximum) containing actual color samples of all exterior finishes, keyed to the elevations, and indicating the manufacturer's name and color designation. _____ Any additional information requested by the Design Review Board at the time of concept approval, such as scale model or color renderings, that the Board finds necessary in order to act on a final application. Additional Submittal Requirements: Alterations/Additions _____ All of the materials required for final approval of proposed development as listed above, plus the following additional materials. _____ A survey (1"=30' minimum scale) of property lines, existing topography and the location of trees meeting the tree protection regulations of Sec. 16-6-104.C.2, and if applicable, location of bordering streets, marshes and beaches. _____ Photographs of existing structure. Additional Submittal Requirements: Signs _____ Accurate color rendering of sign showing dimensions, type of lettering, materials and actual color samples. For freestanding signs: _____ Site plan (1”=30’ minimum scale) showing location of sign in relation to buildings, parking, existing signs, and property lines. _____ Proposed landscaping plan. For wall signs: _____ Photograph or drawing of the building depicting the proposed location of the sign. _____ Location, fixture type, and wattage of any proposed lighting. X X X X X X □ 2.25.26 Page 6 of 68 Page 7 of 68 1 February 25, 2026 Town of Hilton Head Island DRB One Town Center Court Hilton Head Island, SC 29928 Project Narrative for a Renovation of the Atrium Building at 840 William Hilton Pkwy Attached is the final submittal package for the At rium Building at 840 William Hil ton Pkwy that was reviewed for conceptual 1.28.26. Please see our responses to the comments from that review below. • Study the score line . The scorelines were studied on the rear and sides of the building. The windows on the right side were resized and respaced to align with the rhythm of the William Hilton Pkwy. and rear elevations. The score lines in the recesses at the rear were laid out to pick up the rhythm of the window divides on the William Hilton Pkwy. Side. • Incorporate more island character . We studied the proposed materials to incorpor ate neutral tones of stucco and natural wood tones to provided more island character. • Study the columns . The columns on the porches were beefed up to a dimension of 8 ½” wide that is slightly bigger than the current columns. • Provide more landscaping, lighting, outdoor, and overall detail. Full landscaping and lighting along with building details are being included. Building outdoor lighting was al so included on the reflected ceiling plans • Provide adequate and comp atible parking. Parking has been stud ied and complies with the LMO for parking requirements. • Provide roof plan. A roof plan is being provided. Thank you for your time and consideration of this project. Timothy C Probst, AIA parkerdesigngroup/architects8437855171 / PO BOX 5OIO HILTON HEAD ISLAND SC 29938 I PG-ARCHITECTS.COM I O PALMETTO BUSINESS PARK HILTON HEAD ISLAND SC 29928 Page 8 of 68 Page 9 of 68 COVER SHEET AND PROJECT NOTES SHEET INDEX 3 DAYS BEFORE DIGGING CALL TOLL FREE 1-888-721-7877 A ONE-CALL SYSTEM FOR COMMUNITY AND JOB SAFETY UTILITY PROTECTION CENTER ****CAUTION**** CS ISSUED: FEBRUARY 25, 2026 DRB SUBMITTAL PLAN, NOT FOR CONSTRUCTION DRAWING NUMBER DRAWING TITLE DESIGN CONCEPTS, DRAWING, SHEETS, LOGOS, SPECIFICATIONS, DETAILS, WRITTEN MATERIAL SHALL NOT BE USED OR REPRODUCED IN WHOLE OR IN PART IN ANY FORM WITHOUT PRIOR WRITTEN CONSENT OF WJK LTD. © 2026 WJK LTD. THIS SHEET TO SCALE AT: 24"X36" DATE: PROJECT NO.: DRAWN BY: CHECKED BY: FEB 25, 2026 XXXXX.XX SD JC REVISIONS: SITE DEVELOPMENT PLANS FOR ATRIUM BUILDING HILTON HEAD ISLAND, SOUTH CAROLINA 840 WILLIAM HILTON PARKWAY CS - L00 - L50 - L200 - L500 - L501 - L600 - COVER SHEET EXISTING CONDITIONS DEMOLITION / TREE PROTECTION LAYOUT PLAN PLANTING PLAN PLANT SCHEDULE AND DETAILS SITE DETAILS 1. ALL NOTES APPLY TO ALL DRAWINGS AND ALL TRADES. 2. REFER TO ENGINEERING PLANS FOR LAYOUT AND LOCATION OF UTILITIES AND ROADS. 3. ALL SURVEY AND SITE INFORMATION WERE COMPILED FROM A VARIETY OF SOURCES AT VARIOUS TIMES. SITE INFORMATION MUST BE FIELD VERIFIED BEFORE CONSTRUCTION BEGINS. REPORT ANY DISCREPANCIES TO THE OWNER OR OWNER'S REPRESENTATIVE. 4. IT IS THE RESPONSIBILITY OF ALL CONTRACTORS AND TRADES TO COORDINATE THE INSTALLATION OF THEIR WORK WITH THE INSTALLATION OF WORK BY ALL OTHER CONTRACTORS AND TRADES. 5. THE REQUIREMENTS OF THE SPECIFICATIONS, DRAWINGS, GENERAL REQUIREMENTS, AND ALL ITEMS OF THE CONTRACT DOCUMENTS ARE EQUALLY BINDING FOR ALL CONTRACTORS AND TRADES. 6. EACH CONTRACTOR IS REQUIRED TO MAINTAIN FULL (COLOR) SETS OF THE CONTRACT DOCUMENTS FOR HIS EMPLOYEES USE ON THE PROJECT TO ASSURE THAT ALL WORK IS PROPERLY COORDINATED AND FOR REVIEWS BY COUNTY AND / OR MUNICIPALITY OFFICIALS FOR INSPECTIONS. 7. ALL CONTRACTORS AND ALL TRADES ARE RESPONSIBLE FOR OBTAINING THE CORRECT PERMITS AND INSPECTIONS PRIOR TO CONSTRUCTION AS REQUIRED BY LOCAL PLANNING, ZONING, BUILDING CODE AND OTHER TOWN AUTHORITIES. 8. W.J.K. LTD., THE OWNER AND / OR THE OWNER'S REPRESENTATIVE SHALL BE NOTIFIED OF ANY SITE CONDITIONS WHICH MAY NECESSITATE MODIFICATION TO THE PLAN. THE OWNER OR OWNER'S REPRESENTATIVE SHALL MAKE 'INFIELD MODIFICATIONS,' IF NECESSARY. 9. CONTRACTOR SHALL PROVIDE AND FURNISH ALL MATERIALS, EQUIPMENT AND LABOR NECESSARY FOR ALL CONSTRUCTION, PROTECTION, MAINTENANCE AND RELATED ITEMS TO COMPLETE WORK INDICATED ON THE DRAWINGS. 10. BEFORE COMMENCING ANY WORK CONTRACTOR SHALL ASCERTAIN THE LOCATION OF ALL UTILITIES, SUB-SURFACE DRAINAGE, AND UNDERGROUND CONSTRUCTION SO THAT PROPER PRECAUTIONS MAY BE TAKEN NOT TO DISTURB ANY SUB-SURFACE IMPROVEMENTS. CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS IN BRINGING EQUIPMENT ON TO AND OFF OF THE SITE, PROTECTING WALKS, PAVING, STEPS AND OTHER EXISTING CONSTRICTION ON THE SITE. CONTACTS SHALL BE MADE BY CONTRACTOR WITH PROPER AUTHORITIES BEFORE AND DURING THIS WORK SO AS TO COMPLY WITH ALL REGULATIONS AND ORDINANCES. 11. CONTRACTOR SHALL FIELD LOCATE ALL UTILITIES AND CONFIRM / DETERMINE UTILITY ELEVATIONS PRIOR TO CONSTRUCTION. CONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE AND MAKE REPAIRS, AT THEIR OWN EXPENSE, THAT MAY OCCUR TO EXISTING UTILITIES IN ACCORDANCE WITH NATIONAL, STATE AND LOCAL CODES. 12. CONTRACTOR SHALL VERIFY ALL EXISTING TREE CONDITIONS AND ELEVATIONS PRIOR TO CONSTRUCTION. CONTRACTOR SHALL NOTIFY THE OWNER OR OWNER'S REPRESENTATIVE OF ANY DISCREPANCIES PRIOR TO THEIR REMOVAL. 13. CONTRACTOR SHALL PROTECT AND INSTALL TREE PROTECTION FENCE AROUND THE DRIP LINE OF ALL TREES, NATURAL AREAS AND EXISTING VEGETATION TO REMAIN. TREE PROTECTION LOCATION SHALL BE APPROVED BY LANDSCAPE ARCHITECT PRIOR TO CONSTRUCTION. 14. ALL CONSTRUCTION FOR ALL TRADES SHALL CONFORM TO OR EXCEED THE PRODUCT MANUFACTURER'S RECOMMENDATIONS, REGULATIONS OF HILTON HEAD AND THE AMERICANS WITH DISABILITIES ACT, AND / OR OTHER APPLICABLE NATIONAL, STATE, AND LOCAL CODES AND ANY OTHER GOVERNING AUTHORITIES. 15. CONTRACTOR ACCESS FOR CONSTRUCTION AS DIRECTED BY THE OWNER OR OWNER'S REPRESENTATIVE. 16. CONTRACTOR SHALL PROTECT THE GENERAL PUBLIC FROM CONSTRUCTION AREAS DURING CONSTRUCTION. 17. THE OWNER MAY REQUIRE FLAG MEN TO BE AVAILABLE DURING THE CONSTRUCTION PROCESS. 18. ANY DEVIATIONS FROM THESE PLANS MUST BE SPECIFICALLY APPROVED BY W.J.K. LTD., AND THE OWNER OR OWNER'S REPRESENTATIVE. GENERAL NOTES: 1. THE CONTRACTOR, BEFORE BEGINNING ANY DEMOLITION ACTIVITY, SHALL CONTACT THE LOCAL UTILITIES FOR INSTRUCTION ON SPECIAL PROCEDURES THAT MAY BE REQUIRED BY THE UTILITIES CONCERNING DEMOLITION. 2. ALL DEMOLISHED MATERIAL SHALL BE HAULED AWAY AND DISPOSED OF PROPERLY IN A LANDFILL AS APPLICABLE PER HILTON HEAD CODE(S). 3. THE CONTRACTOR SHALL FOLLOW ALL REQUIREMENTS OF LOCAL, STATE AND FEDERAL REGULATORY AGENCIES WHICH MAY HAVE JURISDICTION OVER SUCH ACTIVITIES. 4. THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL DATA PROVIDED IN THESE DRAWINGS. THE CONTRACTOR SHALL PERFORM HIS OWN ESTIMATE OF MATERIAL FOR DEMOLITION AND REPORT ANY DISCREPANCIES TO THE OWNER OR THE OWNER'S REPRESENTATIVE PRIOR TO BEGINNING WORK. 5. ALL UTILITIES SHOWN ON THE DRAWINGS ARE APPROXIMATE AND FOR ESTIMATING PURPOSES ONLY. THE EXACT LOCATIONS SHALL BE FIELD VERIFIED BY THE CONTRACTOR PRIOR TO BEGINNING DEMOLITION WORK. ALL UTILITIES SHALL BE LOCATED AND PROTECTED TO PREVENT DAMAGE. ANY DAMAGE WHICH MAY OCCUR DURING THE CONSTRUCTION PROCESS IS TO BE PROMPTLY REPORTED TO THE APPROPRIATE UTILITY AUTHORITY AND REPAIRS SHALL BE MADE IN ACCORDANCE WITH THEIR REQUIREMENTS. THE SAFE DEMOLITION AND REMOVAL OF UTILITIES, STRUCTURES AND EQUIPMENT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR. 6. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO NOTIFY, AT THE DIRECTION OF THE OWNER OR OWNER'S REPRESENTATIVE, THE UTILITIES HAVING JURISDICTION OVER ANY UTILITY EASEMENTS OF ANY KIND FOR APPROVAL OF WORK WITHIN THE EASEMENT. 7. REMOVAL OF ANY AND ALL MATERIALS INDICATED INCLUDES ALL MATERIALS ASSOCIATED WITH THAT ITEM INCLUDING SUBSURFACE MATERIAL, IF APPLICABLE, NOT NEEDED OR IN NEED OF REPAIR OR REPLACEMENT. 8. THE CONTRACTOR SHALL TAKE CARE WHEN WORKING AROUND EXISTING TREES SCHEDULED TO REMAIN. PROPER TREE PROTECTION IN ACCORDANCE WITH LOCAL CODES SHALL BE MADE PRIOR TO CONSTRUCTION BEGINNING AND THROUGHOUT THE CONSTRUCTION PROCESS. 9. SOME TREES AND SHRUBS SCHEDULED FOR RELOCATION AND REUSE ON THE PROPERTY MAY NOT BE SALVAGEABLE DUE TO UNDERGROUND UTILITIES. 10. BARRIERS AND / OR FLAG MEN MAY BE REQUIRED FOR SAFETY, VERIFY REQUIREMENTS WITH THE OWNER FOR SUCH NEEDS PRIOR TO BEGINNING THE WORK. 11. THE OWNER SHALL BE NOTIFIED AS TO THE TIMING OF THE WORK SO THAT PROPER SECURITY NOTIFICATION IS MADE. DEMOLITION NOTES: 1. ALL CONSTRUCTION STAKING SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. 2. CONTRACTOR TO USE DIGITAL FILES PROVIDED BY WITMER-JONES-KEEFER, LTD. TO LAYOUT AND STAKE ALL SITE IMPROVEMENTS AND ELEMENTS. FINAL LAYOUT AND STAKING TO BE FIELD VERIFIED AND APPROVED BY LANDSCAPE ARCHITECT AND OWNER OR OWNER'S REPRESENTATIVE PRIOR TO CONSTRUCTION. 3. CONTRACTOR SHALL FIELD LOCATE, STAKE AND USE COLOR CODED SPRAY PAINT FOR ALL ABOVE AND BELOW GROUND UTILITIES. CONTRACTOR TO CONFIRM / DETERMINE UTILITY ELEVATIONS PRIOR TO CONSTRUCTION. ANY EXISTING UTILITY CONFLICTS WITH SITE IMPROVEMENTS TO BE REPORTED TO OWNER, OWNER'S REPRESENTATIVE AND LANDSCAPE ARCHITECT PRIOR TO CONSTRUCTION. CONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE TO EXISTING UTILITIES AS STATED IN THE GENERAL NOTES. 4. ALL SITE IMPROVEMENTS REPRESENTED IN THIS SET OF PLANS SHALL BE STAKED AND REVIEWED WITH THE OWNER OR OWNER'S REPRESENTATIVE PRIOR TO CONSTRUCTION. ANY DISCREPANCIES TO BE REPORTED TO THE OWNER, OWNER'S REPRESENTATIVE OR LANDSCAPE ARCHITECT. 5. ALL DIMENSIONS ARE TO EDGE OF PAVING AND CENTERLINE OF WALLS AND COLUMNS UNLESS OTHERWISE INDICATED. 6. ALL ANGLES ARE 90 UNLESS OTHERWISE INDICATED. 7. CONTRACTOR SHALL PROVIDE LIGHTING, IRRIGATION AND ANY OTHER CONDUIT NEEDED TO ALL LANDSCAPE AREAS. 8. ANY AND ALL FIELD ADJUSTMENTS SHALL RECEIVE APPROVAL FROM THE OWNER, OWNER'S REPRESENTATIVE OR LANDSCAPE ARCHITECT PRIOR TO CONSTRUCTION. LAYOUT NOTES: GRADING NOTES: 1. THE INTENT OF THE LIGHTING DESIGN IS TO PROVIDE LOW LEVEL UNOBTRUSIVE SITE LIGHTING OR ARCHITECTURAL ELEMENTS. THE CONTRACTOR SHALL MAKE EVERY EFFORT TO CREATE THIS EFFECT BY CLOSE COORDINATION WITH THE LANDSCAPE ARCHITECT AND CAREFUL PLACEMENT OF ALL FIXTURES. 2. THE CONTRACTOR SHALL ENGINEER THE ELECTRICAL SYSTEM BASED ON THE LOCATION AND TYPE OF FIXTURES AS SHOWN ON THE PLAN. PROPERLY SIZED WIRING, TRANSFORMERS, BREAKERS, ACCESSORIES, ETC., SHALL BE PROVIDED BY THE CONTRACTOR AS NECESSARY TO GUARANTEE A COMPLETELY FUNCTIONAL LIGHTING, DISTRIBUTION AND CONTROL SYSTEM. 3. CONTRACTOR TO PROVIDE ELECTRICAL PLANS AND SHOP DRAWINGS FOR REVIEW AND APPROVAL BY THE LANDSCAPE ARCHITECT AND OWNER OR OWNER'S REPRESENTATIVE PRIOR TO INSTALLATION. 4. ALL LIGHTING EQUIPMENT SHALL BE INSTALLED PER MANUFACTURERS INSTRUCTIONS AND RECOMMENDATIONS, AND MUST COMPLY WITH ALL APPLICABLE STATE AND COUNTY CODES. 5. THE CONTRACTOR IS RESPONSIBLE FOR ACQUIRING ALL NECESSARY PERMITS AND INSPECTION / APPROVALS REQUIRED. 6. THE CONTRACTOR SHALL STAKE OUT ALL LIGHT FIXTURE AND TRANSFORMER LOCATIONS FOR APPROVAL BY THE LANDSCAPE ARCHITECT, OWNER, OR OWNER'S REPRESENTATIVE PRIOR TO INSTALLATION. EXACT LOCATIONS OF CONTROLLERS, ELECTRICAL PANELS, ETC. TO BE COORDINATED WITH AND APPROVED BY OWNER, OWNER'S REPRESENTATIVE OR LANDSCAPE ARCHITECT. 7. FINAL AIMING AND ADJUSTMENT SHALL BE MADE AT NIGHT WITH LANDSCAPE ARCHITECT PRESENT TO GIVE FINAL APPROVAL. 8. THE CONTRACTOR SHALL COORDINATE, STAKE AND FLAG ALL LOCATIONS WHERE ELECTRICAL CONDUIT OR P.V.C. SLEEVING MAY BE REQUIRED BENEATH WALKS OR OTHER PAVED AREAS PRIOR TO HARDSCAPE INSTALLATION. 9. ALL ELECTRICAL WIRING RUNNING UNDER PAVED AREAS SHALL BE PLACED IN ELECTRICAL CONDUIT OR PVC SLEEVES PROVIDED BY CONTRACTOR. 10. CONTRACTOR SHALL RUN ALL NECESSARY ELECTRICAL WIRING TO UTILITY PANEL AND TRANSFORMER. 11. CONTRACTOR SHALL PROVIDE A MINIMUM OF 36" OF BURIES EXCESS CABLE AT EACH FIXTURE TO ALLOW FOR FIXTURE ADJUSTMENT. 12. ALL LIGHTING TO BE PLACED ON AN APPROPRIATE TIMER. THE CONTRACTOR SHALL SELECT AN APPROPRIATE TIMER FOR ALL LIGHTS AND SET THE TIME APPROPRIATELY FOR PROPER NIGHT TIME ILLUMINATION, FOR APPROVAL BY OWNER OR OWNER'S REPRESENTATIVE. 13. CONTRACTOR SHALL PROVIDE GROUND FAULT CIRCUIT BREAKERS FOR ALL CIRCUITS AS REQUIRED BY NATIONAL, STATE AND LOCAL CODES. 14. THE CONTRACTOR SHALL PROVIDE ALL EQUIPMENT, LABOR, EXCAVATION AND BACKFILL NECESSARY TO COMPLETE THE WORK. 15. ALL FIXTURES PER MODELS SPECIFIED UNLESS CONTRACTOR GETS APPROVAL FROM LANDSCAPE ARCHITECT FOR A SUBSTITUTION. 16. SYSTEM INSTALLATION, INCLUDING PARTS AND LABOR, SHALL BE GUARANTEED AND REPAIRED AS NECESSARY BY THE CONTRACTOR FOR ONE YEAR. 17. CONTRACTOR TO PROVIDE "AS-BUILT" DRAWINGS IMMEDIATELY AFTER FINAL ACCEPTANCE, ALONG WITH ALL INSTRUCTION MANUALS FOR ALL EQUIPMENT INSTALLED. 18. IF POSSIBLE, FIELD MODIFICATIONS WILL BE DIRECTED BY THE LANDSCAPE ARCHITECT, OWNER OR OWNER'S REPRESENTATIVE. LIGHTING NOTES: 1. ALL CONTRACTORS AND ALL TRADES ARE RESPONSIBLE FOR OBTAINING THE CORRECT PERMITS AND INSPECTIONS PRIOR TO CONSTRUCTION AS REQUIRED BY LOCAL PLANNING, ZONING, BUILDING CODE AND OTHER TOWN AUTHORITIES. 2. CONTRACTOR SHALL PROVIDE SAMPLES OF ALL MATERIALS AND OBTAIN APPROVAL FROM OWNER, OWNER'S REPRESENTATIVE OR LANDSCAPE ARCHITECT PRIOR TO CONSTRUCTION. 3. ON SITE TOPOGRAPHY MAY REQUIRE ADJUSTMENTS OF FINAL SPOT ELEVATIONS ON SITE FOR PROPOSED VERTICAL CONSTRUCTION ELEMENTS. THE CONTRACTOR SHALL NOTIFY THE OWNER OR OWNER'S REPRESENTATIVE PROMPTLY UPON THE DISCOVERY OF ANY SUCH REQUIRED ADJUSTMENTS. 4. THE CONTRACTOR SHALL PROVIDE FILL AS IS REQUIRED TO OBTAIN PROPER RELATIONSHIP OF FOOTING TO FINISH GRADE REQUIREMENTS - FEATHER FILL TO ADJACENT EXISTING GRADE TO ASSURE A COORDINATED AND DESIRED EFFECT. 5. THE CONTRACTOR IS RESPONSIBLE FOR ALL DAMAGE TO EXISTING CONDITIONS SCHEDULED TO REMAIN DURING CONSTRUCTION. 6. THE CONTRACTOR IS RESPONSIBLE FOR LOCATING ALL EXISTING UTILITIES AND FOR ANY DAMAGE THAT MAY OCCUR TO EXISTING UTILITIES DURING CONSTRUCTION. 7. 'IN-FIELD MODIFICATIONS' MAY BE NECESSARY TO PRODUCE DESIRED EFFECT. MODIFICATIONS TO BE APPROVED BY LANDSCAPE ARCHITECT AND OWNER OR OWNER'S REPRESENTATIVE. 8. ALL WELDS TO BE CONTINUOUS. 9. FOR ALL WOOD MEMBERS, ALL CUTS SHALL BE EVEN AND JOINTS FLUSH. SAND FOUR SIDES AND FILL IMPERFECTIONS, COUNTERSINKS AND NAIL HOLES TO ASSURE EVEN FINISH. 10. CONTRACTOR SHALL VERIFY ALL WOOD MEMBERS FOR APPROPRIATE SIZE, SPACING, ATTACHMENTS AND STRUCTURAL STABILITY PRIOR TO CONSTRUCTION. CONTRACTOR TO REPORT ANY DISCREPANCIES TO OWNER, OWNER'S REPRESENTATIVE OR LANDSCAPE ARCHITECT. 11. ALL NOTCHES SHALL BE SHOP CUT TO ASSURE TIGHT JOINTS. EACH MEMBER SHALL BE DRIVEN HOME TO ASSURE TIGHT FIT. PILOT HOLES SHALL BE DRILLED FOR EACH CARRIAGE BOLT. PLUG, SEAL AND PRIME. 12. FINISH ALL SIDES AND CAULK ALL JOINTS WITH APPROPRIATE EXTERIOR CAULK PRIOR TO FINISHING. 13. ALL CONNECTORS, UNLESS OTHERWISE SPECIFIED, SHALL BE STAINLESS STEEL. BOLTS, THREADED RODS, WASHERS, NUTS AND ALL BUILDING HARDWARE SHALL BE STAINLESS STEEL AND SUITABLE FOR PRESSURE TREATED WOOD. ALL THROUGH BOLTS TO BE SMOOTH SHAFT WITH STAINLESS STEEL NUTS, BOLTS AND WASHERS. ALL NAILS AND FINISH NAILS SHALL BE ANNULAR STAINLESS STEEL. 14. ALL DECKING SHALL BE SECURED WITH STAINLESS STEEL SCREWS SIZED FOR DECK APPLICATION. MINIMUM 3" APART. CONSTRUCTION NOTES: PLANTING NOTES: 1. CONTRACTOR IS RESPONSIBLE FOR INSPECTION OF EXISTING CONDITIONS, INCLUDING UTILITIES, AND PROMPTLY REPORTING ANY DISCREPANCIES OR CONFLICTS WITH PLANTING AREAS. REPORT INFORMATION TO OWNER, OWNER'S REPRESENTATIVE AND LANDSCAPE ARCHITECT. 2. CONTRACTOR SHALL FIELD LOCATE ALL UTILITIES. CONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE AND MAKE REPAIRS THAT MAY OCCUR TO EXISTING UTILITIES IN ACCORDANCE WITH NATIONAL, STATE AND LOCAL CODES. 3. LANDSCAPE PLANTING AND / OR MULCHED AREAS TO BE FINE GRADED, HAND RAKED SMOOTH AND FREE OF DEBRIS. 4. CONTRACTOR TO PERFORM SOIL TESTS AS NECESSARY TO ASSURE PLANT HEALTH AND GROWTH. 5. MULCH ALL PLANTING BEDS TO A MIN. 3" DEPTH WITH MULCH SPECIFIED IN PLANT SCHEDULE. 6. CONTRACTOR VERIFIES THAT ALL PLANT MATERIAL IS DETERMINED AVAILABLE AS SPECIFIED WHEN BID / PROPOSAL IS SUBMITTED. 7. PLANT SCHEDULE WAS PREPARED FOR ESTIMATING PURPOSES ONLY. CONTRACTOR SHALL MAKE OWN QUANTITY TAKEOFFS USING DRAWINGS TO DETERMINE QUANTITIES TO HIS SATISFACTION, REPORTING PROMPTLY ANY DISCREPANCIES WHICH MAY AFFECT BIDDING. 8. GALLON SIZES ARE FOR PRICING PURPOSES ONLY. PLANT MUST MEET HEIGHTS AND WIDTHS SPECIFIED IN PLANT SCHEDULE. 9. ROOT TYPE MAY BE FREELY SUBSTITUTED IN CASE OF BALLED AND BURLAPPED OR CONTAINER GROWN, OTHER SPECIFICATIONS REMAINING UNCHANGED, EXCEPT IN THE CASE OF CONTAINER GROWN SPECIMEN TREES AS INDICATED IN THE TREE PLANTING SCHEDULE. 10. ANY SIGNIFICANT ROOTS ENCOUNTERED 2" DIA. AND LARGER SHALL BE DUG OUT BY HAND AND CLEANLY CUT BACK IN THE FOOTING / FOUNDATION AREA TO PROMOTE ROOT RE-GROWTH AND HELP PREVENT ROOT DIEBACK. 11. ALL PLANT MATERIAL (EXCEPT SEASONAL COLOR) SHALL BE GUARANTEED AND REPLACED AS NECESSARY BY THE CONTRACTOR FOR ONE YEAR. 12. ALL SEASONAL COLOR SHALL BE GUARANTEED AND REPLACED AS NECESSARY BY THE CONTRACTOR FOR THREE MONTH TIME FRAMES. IRRIGATION NOTES: TURF AND GRASSING NOTES: 1. CONTRACTOR TO SUPPLY AUTOMATIC IRRIGATION SYSTEM, COMPLETE AND INSTALLED. SYSTEM TO INCLUDE ALL VALVES, PIPES, HEADS, FITTINGS, BACK FLOW CONTROLLER, AND IRRIGATION METER AND TO PROVIDE 100% COVERAGE FOR ALL NEW PLANTINGS. DRIP IRRIGATION TO BE USED FOR ALL PLANTINGS, EXCEPT LAWNS. 2. NO IRRIGATION COMPONENTS SHALL BE CLOSER THAN 12" TO ANY EDGE OF PAVEMENT OR CURB AND GUTTER. IRRIGATION SHALL NOT SPRAY BEYOND LANDSCAPED AREAS, OR INTO ANY UNDISTURBED BUFFERS. NO OVER SPRAY SHALL BE PERMITTED ONTO ADJACENT PROPERTIES OR PEDESTRIAN SIDEWALK AREAS. 3. LANDSCAPE CONTRACTOR TO FIELD VERIFY ALL COMPONENT LOCATIONS TO ENSURE APPROPRIATE COVERAGE. 4. LANDSCAPE CONTRACTOR SHALL LOCATE WATER SOURCE AND PROVIDE POWER TO CONTROLLER. 5. CONTROLLER LOCATION TO BE SPECIFIED BY OWNERS REPRESENTATIVE IN FIELD PRIOR TO CONSTRUCTION. 6. ALL DRIP TUBING SHALL BE COVERED WITH MIN. 3" OF MULCH. 7. ALL DRIP AND SPRAY ZONES SHALL BE SEPARATE. 8. CONTRACTOR SHALL SUBMIT FINAL IRRIGATION PLANS TO OWNER'S REPRESENTATIVE AND ALL REVIEWING BODIES / AGENCIES FOR FINAL APPROVAL PRIOR TO INSTALLATION. 1. CONTRACTOR SHALL IMPLEMENT ALL SILT FENCE OR OTHER SEDIMENT CONTROL MEASURES AROUND ALL DISTURBED AREAS PRIOR TO ANY CONSTRUCTION ACTIVITIES. 2. TEMPORARY CONSTRUCTION ENTRANCE SHALL BE INSTALLED AFTER SILT FENCE AND PRIOR TO ALL OTHER CONSTRUCTION ACTIVITIES. 3. ALL SEDIMENT AND EROSION CONTROL DEVICES SHALL BE INSPECTED BY THE CONTRACTOR AT LEAST ONCE EVERY FOURTEEN (14) CALENDAR DAYS AND WITHIN 24 HOURS OF THE END OF A STORM EVENT OF 0.5 INCHES OR GREATER. IF SITE INSPECTIONS IDENTIFY B.M.P.S. THAT ARE DAMAGED OR ARE NOT OPERATING EFFECTIVELY, MAINTENANCE MUST BE PERFORMED AS SOON AS PRACTICAL AND BEFORE THE NEXT STORM EVENT IF PRACTICAL. 4. CONTRACTOR TO PROVIDE SILT FENCE AND / OR OTHER CONTROL DEVICES, AS MAY BE REQUIRED, TO CONTROL SOIL EROSION DURING UTILITY CONSTRUCTION. ALL DISTURBED AREAS SHALL BE CLEANED, GRADED AND STABILIZED WITH GRASSING IMMEDIATELY AFTER THE UTILITY INSTALLATION. FILL, COVER AND TEMPORARY SEEDING AT THE END OF EACH DAY ARE RECOMMENDED. IF WATER IS ENCOUNTERED WHILE TRENCHING, THE WATER SHOULD BE FILTERED TO REMOVE ANY SEDIMENTS BEFORE BEING PUMPED BACK INTO ANY WATERS OF THE STATE. 5. ALL EROSION CONTROL DEVICES SHALL BE PROPERLY MAINTAINED BY THE CONTRACTOR DURING ALL PHASES OF CONSTRUCTION UNTIL THE COMPLETION OF ALL CONSTRUCTION ACTIVITIES AND ALL DISTURBED AREAS HAVE BEEN STABILIZED. ADDITIONAL CONTROL DEVICES MAY BE REQUIRED DURING CONSTRUCTION IN ORDER TO CONTROL EROSION AND / OR OFFSITE SEDIMENTATION. ALL TEMPORARY CONTROL DEVICES SHALL BE REMOVED ONCE CONSTRUCTION IS COMPLETE AND THE SITE IS STABILIZED. 6. THE CONTRACTOR MUST TAKE NECESSARY ACTION TO MINIMIZE THE TRACKING OF MUD ONTO PAVED SURFACES FROM CONSTRUCTION AREAS AND THE GENERATION OF DUST. THE CONTRACTOR SHALL REMOVE MUD / SOIL DAILY FROM PAVED SURFACES, AS REQUIRED. 7. RESIDENTIAL SUBDIVISIONS REQUIRE EROSION CONTROL FEATURES FOR INFRASTRUCTURE AS WELL AS FOR INDIVIDUAL LOT CONSTRUCTION. INDIVIDUAL PROPERTY OWNERS SHALL FOLLOW THESE PLANS DURING CONSTRUCTION OR OBTAIN APPROVAL OF AN INDIVIDUAL PLAN IN ACCORDANCE WITH S.C. REG. 72-300 ET SEQ. AND SCR100000. 8. TEMPORARY DIVERSION BERMS AND / OR DITCHES WILL BE PROVIDED AS NEEDED DURING CONSTRUCTION TO PROTECT WORK AREAS FROM UPSLOPE RUNOFF AND / OR TO DIVERT SEDIMENT-LADEN WATER TO APPROPRIATE TRAPS OR STABLE OUTLETS. 9. ALL WATERS OF THE STATE (W.O.S.), INCLUDING WETLANDS, ARE TO BE FLAGGED OR OTHERWISE CLEARLY MARKED IN THE FIELD. A DOUBLE ROW OF SILT FENCE IS TO BE INSTALLED IN ALL AREAS WHERE A 50-FOOT BUFFER CAN'T BE MAINTAINED BETWEEN THE DISTURBED AREA AND ALL W.O.S. A 10-FOOT BUFFER SHOULD BE MAINTAINED BETWEEN THE LAST ROW OF SILT FENCE AND ALL W.O.S. 10. LITTER, CONSTRUCTION DEBRIS, OILS, FUELS AND BUILDING PRODUCTS WITH SIGNIFICANT POTENTIAL FOR IMPACT (SUCH AS STOCKPILES OF FRESHLY TREATED LUMBER) AND CONSTRUCTION CHEMICALS THAT COULD BE EXPOSED TO STORMWATER MUST BE PREVENTED FROM BECOMING A POLLUTANT SOURCE IN STORMWATER DISCHARGES. 11. STABILIZATION MEASURES SHALL BE INITIATED AS SOON AS PRACTICAL IN PORTIONS OF THE SITE WHERE CONSTRUCTION ACTIVITIES HAVE TEMPORARILY OR PERMANENTLY CEASED, BUT IN NO CASE MORE THAN FOURTEEN (14) DAYS AFTER WORK HAS CEASED EXCEPT AS STATED BELOW: 11.1. WHERE STABILIZATION BY THE 14TH DAY IS PRECLUDED BY SNOW COVER OR FROZEN GROUND CONDITIONS, STABILIZATION MEASURES MUST BE INITIATED AS SOON AS PRACTICAL. 11.2. WHERE CONSTRUCTION ACTIVITY ON A PORTION OF THE SITE IS TEMPORARILY CEASED AND EARTH-DISTUBING ACTIVITIES WILL BE RESUMED WITHIN 14 DAYS, TEMPORARY STABILIZATION MEASURES DO NOT HAVE TO BE INITIATED ON THAT PORTION OF THE SITE. GENERAL DISTURBANCE NOTES: 1. CONTRACTOR SHALL VERIFY ALL ELEVATIONS PRIOR TO CONSTRUCTION AND NOTIFY OWNER'S REPRESENTATIVE OF DISCREPANCIES. 2. CROSS SLOPES ON ALL HARDSCAPE WALKWAYS / PATHWAYS ARE NOT TO EXCEED 2%. 3. ALL ACCESSIBLE WALKWAYS / PATHWAYS RUNNING SLOPE (GRADIENT) MAY NOT EXCEED 4.9%, UNLESS A RAMP IS INSTALLED. IF A RAMP IS INSTALLED THE RUNNING SLOPE (GRADIENT) SHALL NOT EXCEED 8.33%, AND HANDRAILS SHALL BE INSTALLED ON BOTH SIDES (MINIMUM 36" CLEARANCE BETWEEN HANDRAILS) WHEN RAMP RISE IS GREATER THAN 6". 4. IF DISCREPANCIES DEVELOP BETWEEN THE PROPOSED GRADES AS SHOWN ON THE PLAN AND THE EXISTING GROUND SURFACE, THE CONTRACTOR, WITH PRIOR APPROVAL FROM THE OWNER'S REPRESENTATIVE, SHALL MAKE GRADING ADJUSTMENTS NECESSARY TO MAINTAIN THE GENERAL INTENT OF THE DESIGN. 5. CONTRACTOR IS RESPONSIBLE FOR ALL PAVED AREAS DAMAGED DURING CONSTRUCTION. 6. CONTRACTOR SHALL PROVIDE POSITIVE DRAINAGE AWAY FROM ALL ADJACENT PROPERTIES, WALLS, WALKS AND PLANTING BEDS AND TOWARDS EXISTING DRAIN INLETS, SWALES, STORMWATER LAGOONS OR ROADS. 7. ALL DISTURBED AREAS INCLUDING SHALLOW SWALES SHALL BE MULCHED OR PLANTED AS INDICATED ON PLANTING PLANS. 8. IF REQUIRED, POP UP EMITTER SHALL BE N.D.S. 6" POP UP DRAINAGE EMITTER BLACK IN COLOR. 9. LANDSCAPE DRAIN SHALL BE AS SPECIFIED ON PLANS. 10. LANDSCAPE DRAINS SHALL BE ADDED TO PROVIDE POSITIVE DRAINAGE AWAY FROM BUILDINGS IN LOW / FLAT AREAS THAT DID NOT SHOW UP ON THE TOPOGRAPHIC SURVEY. LANDSCAPE DRAIN SHALL BE APPROVED BY OWNER, OWNER'S REPRESENTATIVE OR LANDSCAPE ARCHITECT PRIOR TO INSTALLATION. 1. GRASS SEED: PROVIDE FRESH, CLEAN, NEW-CROP SEED COMPLYING WITH TOLERANCE FOR PURITY AND GERMINATION ESTABLISHED BY OFFICIAL SEED ANALYSIS OF NORTH AMERICA. PROVIDE SEED MIXTURE COMPOSED OF GRASS SPECIES, PROPORTIONS AND MINIMUM PERCENTAGES OF PURITY, GERMINATION, AND MAXIMUM PERCENTAGE OF WEED SEED, AS SPECIFIED SEED MANUFACTURER. 2. SOD SHALL BE STRONGLY ROOTED AND FREE OF PERNICIOUS WEEDS. ALL NETTING SHALL BE REMOVED FROM SOD BEFORE IT IS LAID. 3. ALL AREAS IN WHICH EARTHWORK SHALL BE SUSPENDED FOR MORE THAN TWO (2) WEEKS SHALL BE GRASSED WITH TEMPORARY GRASS. 4. AFTER TOPSOIL HAS BEEN INSTALLED, AND BEFORE ANY SOD IS LAID, CORRECT ALL SOFT SPOTS AND IRREGULARITIES IN GRADE. THE SOD SHALL BE BE LAID BY BUTTING THE ENDS AND SIDES UP EVENLY AND STAGGERING THE ROLLS OF SOD. CONTRACTOR SHALL NOT OVERLAP SOD. AS SOON AS THE SOD IS LAID OR AS IT IS BEING LAID ROLL OVER WITH A LIGHT ROLLER, MAKING CERTAIN THAT ALL OF THE SOD IS IN CONTACT WITH THE SOIL. THE COMPLETED SODDED AREAS SHALL BE TRUE TO FINISH GRADE, EVEN AND FIRM AT ALL POINTS. 5. SEED SHALL BE AT A RATE OF 10 POUNDS PER ACRE. 6. THIRTY DAYS AFTER LAST SEEDING/SODDING OPERATION, APPLY 1 POUND OF TYPE A NITROGEN FERTILIZER PER ACRE OF LAWN AREAS AND IMMEDIATELY WATER. 7. UPON COMPLETION OF PLANTINGS ALL EXCESS SOIL STONES AND DEBRIS WHICH HAS NOT PREVIOUSLY BEEN CLEANED UP SHALL BE REMOVED FROM THE SITE AND DISPOSED OF AS DIRECTED BY THE OWNER'S REPRESENTATIVE. 8. ALL LAWN AREAS THAT DO NOT SHOW SATISFACTORY GROWTH WITHIN (18) DAYS AFTER PLANTING SHALL BE RE-PLANTED AND RE-FERTILISZED AS SPECIFIED UNTIL A SATISFACTORY LAWN IS ESTABLISHED. THE LAWN SHALL BE CONSIDERED ESTABLISHED WHEN ITS REASONABLY FREE FROM WEED, GREEN IN APPEARANCE AND THE SPECIFIED GRASS IS VIGOROUS AND GROWING WELL ON EACH SQ. FT. OF LAWN AREA. 9. LAWN SHALL BE PROTECTED AND MAINTAINED BY WATERING, MOWING, AND REPLANTING, OVERSEEING, AS NECESSARY FOR AS LONG AS IS NECESSARY TO ESTABLISH A UNIFORM STAND. SCATTERED BARE SPOTS, NONE OF WHICH IS LARGER THAN ONE SQ. FT., WILL BE ALLOWED UP TO MAXIMUM OF THREE PERCENT OF ANY LAWN AREA. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO REPAIR ANY EROSIONAL DAMAGE TO THE LAWN AREA. FULL COVERAGE IS REQUIRED IN SIXTY DAYS. 10. MAINTENANCE OF GRASSED AREAS SHALL CONSIST OF MOWING, WATERING AND FERTILIZING. ALL GRASSED AREAS SHALL BE MAINTAINED AT A HEIGHT NOT TO EXCEED 6" ABOVE FINISHED GRADE. 11. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO MAINTAIN ALL GRASSED AREAS UNTIL ACCEPTANCE BY OWNER AT END OF PROJECT. LAWN MAINTENANCE SHALL OCCUR AT A MINIMUM OF ONCE PER SEVEN CALENDAR DAYS. 12. FINAL SEEDING AND SOD AREAS / SQUARE FOOTAGES TO BE PAINTED IN FIELD AND APPROVED AND ADJUSTED IN FIELD BY OWNER'S REPRESENTATIVE PRIOR TO INSTALLATION. 13. SEEDING SHALL TAKE PLACE IMMEDIATELY AFTER FINE GRADING. MAINTAIN SEEDED LAWN UNTIL COMPLETION AND ACCEPTANCE OF ENTIRE PROJECT. 14. SEEDING BED SHALL HAVE TOPSOIL LOOSEN TO A DEPTH OF 4". REMOVE STONE OVER 1" IN ANY DIMENSION, ROOTS, RUBBISH, AND EXTRANEOUS MATTER. 1. TOPSOIL SHALL CONSIST OF THE NATURAL LOAM, SANDY LOAM, SILT LOAM, OR CLAY LOAM HUMUS BEARING SOILS, ADAPTED TO THE SUSTENANCE OF PLANT LIFE, WITH THE FOLLOWING TEXTURE: 1.1. ORGANIC MATERIAL - TWO (2) TO TWENTY (20) PERCENT BY MASS 1.2. SAND CONTENT - TWENTY (20) TO SIXTY (60) PERCENT BY MASS 1.3. CLAY-SILT CONTENT – THIRTY FIVE (35) TO SEVENTY (70) PERCENT BY MASS. 1.4. TOPSOIL PH SHALL BE BETWEEN FIVE (5) AND SEVEN (7). 2. TOPSOIL SHALL BE OF UNIFORM QUALITY AND FREE FROM FOREIGN MATERIAL SUCH HARD CLODS, SOD, STIFF CLAY, HARD PAN, STONES LARGER THAN ONE (1) INCH DIAMETER, LIME CEMENT, ASHES, SLAG, CONCRETE, TAR RESIDUES, TARRED PAPER, BOARDS, CHIPS, STICKS, OR OTHER UNDESIRABLE MATERIALS. IT SHALL ALSO BE REASONABLY FREE FROM WEEDS AND OBJECTIONABLE PLANT MATERIAL. 3. AFTER ALL DEMOLITION, CLEARING AND DISPOSAL IS COMPLETED, THE CONTRACTOR SHALL STRIP FROM THE TOP OF THE EXISTING GROUND ALL TOPSOIL IN ALL AREAS TO BE GRADED. 4. PRIOR TO STOCKPILING OF TOPSOIL, TOPSOIL SHALL BE SCREENED WITH A ONE HALF (1/2) INCH SIZE SIEVE. STOCKPILE TOPSOIL IN DESIGNATED OR APPROVED LOCATIONS WITH PROPER DRAINAGE AND WHERE IT WILL NOT INTERFERE WITH THE WORK. AFTER TOPSOIL HAS BEEN STOCKPILED, CONTRACTOR SHALL QUANTIFY THE AMOUNTS AT NO ADDITIONAL COST TO THE OWNER. QUANTITIES SHALL BE GIVEN TO THE ARCHITECT, OWNER AND SITE DESIGN PROFESSIONAL. 5. IF AMOUNT OF SCREENED TOPSOIL STOCKPILED FROM STRIPING OPERATIONS IS INSUFFICIENT TO PROVIDE THE NECESSARY AMOUNTS (4" MINIMUM DEPTH), IT SHALL BE THE CONTRACTOR’S RESPONSIBILITY TO OBTAIN (FROM OFF-SITE SOURCE) THE NECESSARY AMOUNT OF SCREENED TOPSOIL TO COMPLETE THE PROJECT. 6. SCREENED TOPSOIL SHALL BE DISTRIBUTED WITH A MINIMUM DEPTH OF FOUR (4) INCHES TO ALL GRADED AREAS (NOT INCLUDING BUILDING, PAVED, SYNTHETIC TURF, PERVIOUS PAVEMENT, ETC.) AND / OR AS DIRECTED BY THE OWNER OR OWNER'S REPRESENTATIVE. GROUND SHALL BE SCARIFIED BEFORE PLACING TOPSOIL. AREAS WHERE SCREENED TOPSOIL IS DISTRIBUTED SHALL BE STABILIZED WITH TEMPORARY AND/OR PERMANENT VEGETATION (SEASON DEPENDENT) OR TEMPORARY MULCH WITHIN FOURTEEN (14) CALENDAR DAYS OF DISTRIBUTION. SOIL AMENDMENT NOTES: 7 9 ashones.#; .""alandscape architecture ~land planning www.wjkltd.com 23 Promenade Street, Suite 201 W Bluffton, South Carolina # 29910 ph 843.757.7411 Page 10 of 68 29 DBH LIVE OAK (SIGNIFICANT TREE) - EXISTING CANOPY IMPACT: 5% 28 16 17 DBH LIVE OAK (SPECIMEN TREE) - EXISTING CANOPY IMPACT: 21% 24 DBH LAUREL OAK (SIGNIFICANT TREE) - EXISTING CANOPY IMPACT: 3% 29 DBH WATER OAK (SIGNIFICANT TREE) - EXISTING CANOPY IMPACT: 30% 26 DBH LIVE OAK (SIGNIFICANT TREE) - EXISTING CANOPY IMPACT: 65% 30 DBH LIVE OAK (SPECIMEN TREE) - EXISTING CANOPY IMPACT: 0% 50 DBH LIVE OAK (SPECIMEN TREE) - EXISTING CANOPY IMPACT: 20% 25 DBH WATER OAK (SIGNIFICANT TREE) - EXISTING CANOPY IMPACT: 14% 32 DBH LAUREL OAK (SPECIMEN TREE) - EXISTING CANOPY IMPACT: 17% SPECIMEN AND SIGNIFICANT TREE ENCROACHMENT SUMMARY: A B D C E G F H I SITE ANALYSIS PLAN DRB SUBMITTAL PLAN, NOT FOR CONSTRUCTION DRAWING NUMBER DRAWING TITLE DESIGN CONCEPTS, DRAWING, SHEETS, LOGOS, SPECIFICATIONS, DETAILS, WRITTEN MATERIAL SHALL NOT BE USED OR REPRODUCED IN WHOLE OR IN PART IN ANY FORM WITHOUT PRIOR WRITTEN CONSENT OF WJK LTD. © 2026 WJK LTD. THIS SHEET TO SCALE AT: 24"X36" DATE: PROJECT NO.: DRAWN BY: CHECKED BY: FEB 25, 2026 XXXXX.XX SD JC REVISIONS: SITE DEVELOPMENT PLANS FOR ATRIUM BUILDING HILTON HEAD ISLAND, SOUTH CAROLINA 840 WILLIAM HILTON PARKWAY L00 c N E W 0 20 40 60 80 10 30 50 70 Scale 1 " = 20' EXISTING CONDITIONS REFERENCE NOTES: 1EXISTING PERVIOUS SURFACE (LANDSCAPE AREAS). EXISTING IMPERVIOUS SURFACE - ASPHALT. EXISTING IMPERVIOUS SURFACE - CONCRETE. ENTRY LANE - ONE WAY. EXIT LANE - ONE WAY. PROPERTY SIGN. PARKING EASEMENT - OFF PROPERTY AREA. EXISTING GRAVEL PARKING EXISTING SPECIMEN TREE. EXISTING SIGNIFICANT TREE. 2 3 4 5 6 ATRIUM BUILDING WILLIAM HILTON PARKWAY - US HIGHWAY 278 ADJACENT PARKING ADJACENT PARKING HOME 2 SUITES PROPERTY LINE PROPERTY LINE PROPERTY LINE PROPERTY LINE 50' TYPE 'E' OPTION 1 BUFFER 20' ADJACENT USE SETBACK 20' ADJACENT USE SETBACK 20' ADJACENT USE SETBACK 1 1 1 2 2 2 3 3 3 4 5 6 SIDEWALK DITCH MARINA SIDE DRIVE STACK'S PANCAKES RESTAURANT TREE IMPACT LEGEND SYMBOL DESCRIPTION TREE CANOPY - SPECIMEN SPECIMEN TREE IMPACTS - EXISTING SIGNIFICANT TREE IMPACTS - EXISTING NOTE: HATCHES ARE GRAPHIC IN NATURE AND ARE NOT INTENDED TO BE TO SCALE. LOWEST LIMB WITH CLEARANCE FROM GRADE+12' TREE CANOPY - SIGNIFICANT 7 8 9 10 2 2 3 7 7 7 8 9TYP. 10TYP. PROJECT INFORMATION: ZONING ZONING DISTRICT: LIGHT COMMERCIAL (LC) OVERLAY DISTRICT: ROW-ARTERIAL (COR) USE OF PROPERTY: OTHER COMMERCIAL USE SITE GROSS SITE ACREAGE: 1.95 AC. NET SITE ACREAGE: 1.95 AC. AREA OF DISTURBANCE: 0.5 AC. DENSITY ALLOWED TOTAL DENSITY: 19,500 GFA (10,000 GFA PER ACRE) EXISTING BUILDING SQUARE FOOTAGE: 18,850 GFA PROPOSED BUILDING SQUARE FOOTAGE: 18,850 GFA BUILDING HEIGHT MAXIMUM HEIGHT ALLOWED: 45' PROPOSED BUILDING HEIGHT: AS EXISTING <45' SITE IMPERVIOUS MAXIMUM ALLOWED IMPERVIOUS AREA: 50,838 SF (60% OF SITE) CURRENT IMPERVIOUS AREA: 52,597 SF (62% OF SITE) PROPOSED IMPERVIOUS AREA: 49,600 SF (58% OF SITE) PARKING MINIMUM NUMBER OF PARKING SPACES REQUIRED: 119 (5 ACCESSIBLE SPACES) EXISTING NUMBER OF PARKING SPACES: 96 (5 ACCESSIBLE) PROPOSED NUMBER OF PARKING SPACES: 116 (5 ACCESSIBLE) + 4 SPACES FROM BIKE CREDIT (40 BIKE SPACES) = 120 TOTAL FLOOD ZONE ZONE 'X' SHOWN ON MAP 45013C0461G, DATED 03/23/21 50' ARTERIAL SETBACK A B D C E G F H I 7 7 SOUTHERN BOUNDARY (240 LF) - WM. HILTON PARKWAY TYPE 'E' OPTION 1 (50') MAJOR ARTERIAL BUFFER EASTERN BOUNDARY (350 LF) - SHARED COMMERCIAL (LC ZONING) PROPERTY LINE NO EXTERIOR BOUNDARY BUFFER REQUIRED WESTERN BOUNDARY (355 LF) - SHARED COMMERCIAL (LC ZONING) PROPERTY LINE NO EXTERIOR BOUNDARY BUFFER REQUIRED NORTHERN BOUNDARY (240 LF) - SHARED COMMERCIAL (LC ZONING) PROPERTY LINE NO EXTERIOR BOUNDARY BUFFER REQUIRED ~~ 11: 'Re $$$ c% a- $°o~0> £ 8- ,~ 0;"' eso £ c:D,t:.:'tl5 -o)3 1?ismg8 3'i,!cl s '+ $s z;±3 $ a ,.ti!.:- d,is~ ~8 D- 1 % gs0 ;f ~'£0tgQ0 a £03 "' oooooooooo ---------- MM%MMMMt MM%2% ooooooooo -------- /////////////// /II //// /////////////////' /////IIIIIIIIII ~~ oI I I I ( \ \ - -SEMEN unu@,» (ERREF a Ie I o \ Lu22 PNLo10 MENT .AT#4) p@8M40810 I I I PNLO10 l-----, ~ ,..... , ]ACCESS&UTILITYEASEMENT (PERREF.PLAT4) II co ( m sPVC INIE»11.11 10p 1~3 t _y-) )o PLO1C 110 I,',-, .,.,,< I I I co I Lr ]reI I 1814 'r... oo si' -3., I e I a I ag$e] +° k I HOL L2 o o lLs1 - 5 pt-~ 0/\ilzi /UTILITYEASEMENTS~,,,I .-----,A(kiri6tau,@ 2s72a"ts:+ssssss+·ssssso ;'/,-,<> ~~VCINIE-9.29 \_J'I- 1Pv¢NIE=9.26 -- '=~n'\--- -_,,_....._-~9.00',o·PVCOUTIE•9.18~--- _?.... BJ,,~ ----/,,~-,-IUTILITYEASEMENT tfl /- L(PERREF.PLAT#4) ;·OM±l+ 'C, I /.,.I.>.,~ :J) DEOG£OFAsPHALT.,.''., I 7 += %$5,_Ji o) "'""'""''"111v'>PNLOB10/._,-,<> I I ,PNA0B10 &o- .-of ] e I 9s,{ 7,$I + l a I a I a I a } EDGEOFASPHALT weD] ;/:<-/':._:-:-~~~:,·:-::·/;''/ ,,,,4e (c co ts ---a I \ I I $g I t7------~--~ [T] e',UlssunroP-15.23 le'\'{'vci-10.01 »·ss ssssssiidpvcUrIE=9.91 8«'$syssssssss«@so ,l1)\ 'I- __I\-....,v-'\I(TOTAL)\ □~9 -'ri-~_N47"46'34"E~.,n\._ YI3•CONC. o._~(. ~-t)I-r-_-=\/ --"--"'4"-r--1 •-""'uCONCRElE 136.49'0; /II 1ODUMPSTERPAD /\(-;;,,~"t-.iPU,tHCHY12sLO 1:A <o-il '34$-%@%}2"a».sf h--±ill[/f 0 -4%i{ t'et'?gks 3]+,[ ', ,,s», sl/«e i··1f[ -7, I I I I I I I ///// 11 NAGE&UTILITYEASEMENT (PERREF.PLATj6) ROSSEASEMENT #6) »-0156--0000 ll..t-0156-0000 ~ 4sSINC. ii-0154-0000 » ll Page 11 of 68 van DEMOLITION PLAN / TREE PROTECTION L50 DRB SUBMITTAL PLAN, NOT FOR CONSTRUCTION DRAWING NUMBER DRAWING TITLE DESIGN CONCEPTS, DRAWING, SHEETS, LOGOS, SPECIFICATIONS, DETAILS, WRITTEN MATERIAL SHALL NOT BE USED OR REPRODUCED IN WHOLE OR IN PART IN ANY FORM WITHOUT PRIOR WRITTEN CONSENT OF WJK LTD. © 2026 WJK LTD. THIS SHEET TO SCALE AT: 24"X36" DATE: PROJECT NO.: DRAWN BY: CHECKED BY: FEB 25, 2026 XXXXX.XX SD JC REVISIONS: SITE DEVELOPMENT PLANS FOR ATRIUM BUILDING HILTON HEAD ISLAND, SOUTH CAROLINA 840 WILLIAM HILTON PARKWAY DEMOLITION REFERENCE NOTES: 1PROTECT EXISTING PAVEMENT(S) DURING CONSTRUCTION. PAVEMENT TO BE MAINTAINED AND INTEGRATED WITH NEW CONSTRUCTION. EXISTING TREE TO REMAIN, DO NOT DISTURB, PROTECT IN PLACE. EXISTING PAVEMENT, INCLUDING SUB-BASES AND ALL ASSOCIATED MATERIAL (REBAR, ETC.) TO BE REMOVED. LEGALLY DISPOSE OF OFF SITE. SEE CIVIL PLAN. EXISTING TREE TO BE REMOVED INCLUDING ROOTS AND STUMP, LEGALLY DISPOSE OF OFF SITE. EXISTING STRIPING TO BE STRIPPED / REMOVED. MITIGATE SOIL COMPACTION WITH 12" OF HARDWOOD MULCH BETWEEN TREE PROTECTION FENCE AND STRUCTURE. REMOVE DUMPSTER AND ASPHALT FROM THIS AREA. 2 4 3 5 6 0 20 40 60 80 10 30 50 70 Scale 1 " = 20' c N E W PLANT PROTECTION LEGEND SYMB.DETAIL DESCRIPTION CALL- OUT 1.1TREE PROTECTION FENCE - WOOD1/L50 1.2TREE PROTECTION FENCE - ALT (ORANGE)1/L50 SITE DEMOLITION LEGEND SYMB. DESCRIPTION TREE TO BE REMOVED - SEE SHEET L500 & L501 FOR MITIGATION CALL- OUT NOTE: DEMOLITION HATCHES ARE GRAPHIC IN NATURE AND ARE NOT INTENDED TO BE TO SCALE. 2.2SILT FENCE - SEE CIVIL ENGINEERS PLANS 2.1 ATRIUM BUILDING WILLIAM HILTON PARKWAY - US HIGHWAY 278 ADJACENT PARKING ADJACENT PARKING HOME 2 SUITES PROPERTY LINE PROPERTY LINE PROPERTY LINE PROPERTY LINE SIDEWALK DITCH STACK'S PANCAKES RESTAURANT TREE IMPACT LEGEND SYMBOL DESCRIPTION TREE CANOPY - SPECIMEN SPECIMEN TREE IMPACTS - EXISTING SIGNIFICANT TREE IMPACTS - EXISTING NOTE: HATCHES ARE GRAPHIC IN NATURE AND ARE NOT INTENDED TO BE TO SCALE. TREE CANOPY - SIGNIFICANT 1L50TREE PROTECTION FENCE SCALE: 1" - 1'-0" SECTION 4", TYP. 101 2" 3'-3" 7" 11" 6'-8' O.C., FIELD ADJUST TO PROTECT TREE 41 2" SLOTS 3'-10" 2' 6" RADIUS = 1 2 X D.B.H. OR 5', WHICHEVER IS GREATER 3"X6" CEDAR SPLIT RAIL UPRIGHTS, NATURAL FINISH 2"X4" CEDAR SPLIT RAILS WITH TAPERED TIPS TO MEET SLOTS, NATURAL FINISH COMPACTED AGGREGATE BASE EXISTING SUBGTADE WARNING SIGN 24"x24" MIN. TREE PROTECTION ZONE DOT NOT ENTER ZONA DE PROTECCION DE ARBOLES NO ENTRAR ALTERNATIVE FENCING: BRIGHT ORANGE PLASTIC MESH - 48" HT. WITH REQUIRED SIGNAGE. PER TOWN OF HILTON HEAD LMO SEC. 16-6-104.3 1 TYP. 2 TYP. 3 TYP. 4TYP. 5 6 50' TYPE 'E' OPTION 1 BUFFER 20' ADJACENT USE SETBACK 20' ADJACENT USE SETBACK 20' ADJACENT USE SETBACK MARINA SIDE DRIVE 50' ARTERIAL SETBACK SPECIMEN AND SIGNIFICANT TREE ENCROACHMENT SUMMARY: A B D C E 29 DBH LIVE OAK (SIGNIFICANT TREE) - EXISTING CANOPY IMPACT: 5% PROPOSED CANOPY IMPACT: 5% (NO CHANGE G F H I 28 16 17 DBH LIVE OAK (SPECIMEN TREE) - EXISTING CANOPY IMPACT: 21% PROPOSED CANOPY IMPACT: 14% 24 DBH LAUREL OAK (SIGNIFICANT TREE) - EXISTING CANOPY IMPACT: 3% PROPOSED CANOPY IMPACT: 3% (NO CHANGE) 29 DBH WATER OAK (SIGNIFICANT TREE) - EXISTING CANOPY IMPACT: 30% PROPOSED CANOPY IMPACT: 13% 26 DBH LIVE OAK (SIGNIFICANT TREE) - EXISTING CANOPY IMPACT: 65% PROPOSED CANOPY IMPACT: 65% (NO CHANGE) 30 DBH LIVE OAK (SPECIMEN TREE) - EXISTING CANOPY IMPACT: 0%PROPOSED CANOPY IMPACT: 13% 50 DBH LIVE OAK (SPECIMEN TREE) - EXISTING CANOPY IMPACT: 20%PROPOSED CANOPY IMPACT: 20% (NO CHANGE) 25 DBH WATER OAK (SIGNIFICANT TREE) - EXISTING CANOPY IMPACT: 14% PROPOSED CANOPY IMPACT: 14% (NO CHANGE) 32 DBH LAUREL OAK (SPECIMEN TREE) - EXISTING CANOPY IMPACT: 17% PROPOSED CANOPY IMPACT: 17% (NO CHANGE) DITCH 7 7 2.3DEMOLITION LIMITS - SEE CIVIL ENGINEERS PLANS 2.3TYP. 2.3 2.3 1.2TYP. 1.1TYP. 1.1TYP. 1.2TYP. II K--- -t.=---... t•- X --- 2888 oooo ooo -- ,,J////o //o //o //o /o //o //o //o , /o ///II/I L ----- ••••••••• ~ » I I I I ( \ 4' ''= tl['E ,,,,,--- > /II MMMM% MM\MM% -- TAXM "e a9 I a I e I e + uTITY (PERRE \ I") --. 1 8unurEASEMENT tsRr.PA#) .." 4 «'!-"\\I I /1D s 0 A22 PNLO810 pM4010 PNLOB [...... I rPNLOB10 UTILITYEASEMENT (PERREE.PLAT#4) UTILITYEASEMENT (PERREF.PLATi4) lACCESS&¢UTILITYEASEMENT (PERREF.PLATj4) I ee a I a I DRAINAGEEASEMENT 7 (PERREF.PLAT#4) I po/1li UTILITY EASEMENTS~,I PERREF.PLATj4) ts$;sssssssss,@ 10•PVCINIE•9.29 \_j" ' 10"PVCINIE+9.26 10"PVCOUTIE»9.18 ,---- unurYEAsEuENrwk "isL--(PER REF.PLAT #4)-t- ••" I a I e I e I 7+8¥,'ttII I a I a I « a:e%6 ••10 \.. ) I ~I « I.• 4t I..--- • {os10 'a..y%·>.."-.el Te@It al [] --[ill [ i ] ~~~-~-~--==-E'--"'--,- \~ [ssu+To-15.23 ks"iovcE-10.o1.PA58_NJ gssss\16Pv¢ouriE-9.91/t'REE;\T fsst@gs t·5,£, s\, I WILLIAMHIITONPARKWAY-USHIGHWAY278 IUI/v 55 ±r %% t6 ~ 88 88 " (cveEhtz%?s)"TT-•·." LAY; 0P~16 \---- covRED-] STORAGESHED • I \ I ///// ¥/1 3 /////// y/1I CESS&CROSSEASEMENT REF.PLAT#6) DRAINAGE&UTILITYEASEMENT (PERREF.PLAT#6) D14 AwRRILL l--011-000--0156--0000 k,PLAT6) D16 wRRIIILLC -011-000--0156-0000 ,PLATj6) 12)ENTERPRISESINC. --011-000-0154-0000 PLAT/6) Page 12 of 68 van 5' 18' 10' 9' 24' 24' R15' 24' 30' 24' 6' LAYOUT PLAN L200 DRB SUBMITTAL PLAN, NOT FOR CONSTRUCTION DRAWING NUMBER DRAWING TITLE DESIGN CONCEPTS, DRAWING, SHEETS, LOGOS, SPECIFICATIONS, DETAILS, WRITTEN MATERIAL SHALL NOT BE USED OR REPRODUCED IN WHOLE OR IN PART IN ANY FORM WITHOUT PRIOR WRITTEN CONSENT OF WJK LTD. © 2026 WJK LTD. THIS SHEET TO SCALE AT: 24"X36" DATE: PROJECT NO.: DRAWN BY: CHECKED BY: FEB 25, 2026 XXXXX.XX SD JC REVISIONS: SITE DEVELOPMENT PLANS FOR ATRIUM BUILDING HILTON HEAD ISLAND, SOUTH CAROLINA 840 WILLIAM HILTON PARKWAY SITE HARDSCAPE LEGEND SYMB.DETAIL DESCRIPTION CALL- OUT 3.2 ASPHALT (ROAD) - SEE CIVIL PLANS CONCRETE (SIDEWALK) 3.3 LOADING ZONE 2/L600 0 20 40 60 80 10 30 50 70 Scale 1 " = 20' c N E W 3.1 BRICK PAVER AREA SITE FURNISHINGS SCHEDULE SYMB. 13.1 CALL- OUT 13.2 13.3 DESCRIPTIONQTY. 8 1 BIKE RACK - SEE DETAIL 6/L600 DUMPSTER ENCLOSURE- SEE ARCHITECTURE PLANS NOTE: SITE FURNISHING SYMBOLS ARE GRAPHIC IN NATURE AND ARE NOT INTENDED TO BE TO SCALE. REFER TO SITE DETAILS FOR SIZES AND DIMENSIONS. DESCRIPTIONQUANTITY EXISTING95 PROPOSED (INCLUDING 5 ADA SPOTS) BIKE PARKING 119 (+24) 34 PARKING OVERVIEW ATRIUM BUILDING WILLIAM HILTON PARKWAY - US HIGHWAY 278 ADJACENT PARKING ADJACENT PARKING HOME 2 SUITES PROPERTY LINE PROPERTY LINE PROPERTY LINE PROPERTY LINE SIDEWALK DITCH STACK'S PANCAKES RESTAURANT 3.4 WHEEL STOP32 NA 1/L600 NA KEY SHEET REFERENCE NOTES: 1 PLANTING AREA, TYP., REFER TO PLANTING PLANS MAINTAIN EXISTING ENTRANCE ACCESS. MAINTAIN EXISTING CONCRETE AT ENTRY AND UNDER EXISTING STRUCTURE. PARKING LOT TO BE RESTRIPED. A.D.A. ACCESSIBLE PARKING. NEW CONCRETE WALK SHALL BE KEPT AT SAME ELEVATION AND SLOPE AS EXISTING CONCRETE WALK. TIE PROPOSED CONCRETE INTO EXISTING CONCRETE EVENLY AND SMOOTHLY. TIE PROPOSED BRICK INTO EXISTING CONCRETE EVENLY AND SMOOTHLY. TIE PROPOSED ASPHALT INTO EXISTING ROAD. 2 4 3 5 6 7 8 P.A. P.A. P.A. 1 2 2 3 3 3 4 TYP. 5 5 7 6 8 13.3 13.2TYP. 3.1TYP. 3.2TYP. 3.3TYP. 3.4 3 50' TYPE 'E' OPTION 1 BUFFER 20' ADJACENT USE SETBACK 20' ADJACENT USE SETBACK 20' ADJACENT USE SETBACK MARINA SIDE DRIVE PROJECT INFORMATION: ZONING ZONING DISTRICT: LIGHT COMMERCIAL (LC) OVERLAY DISTRICT: ROW-ARTERIAL (COR) USE OF PROPERTY: OTHER COMMERCIAL USE SITE GROSS SITE ACREAGE: 1.95 AC. NET SITE ACREAGE: 1.95 AC. AREA OF DISTURBANCE: 0.5 AC. DENSITY ALLOWED TOTAL DENSITY: 19,500 GFA (10,000 GFA PER ACRE) EXISTING BUILDING SQUARE FOOTAGE: 18,850 GFA PROPOSED BUILDING SQUARE FOOTAGE: 18,850 GFA BUILDING HEIGHT MAXIMUM HEIGHT ALLOWED: 45' PROPOSED BUILDING HEIGHT: AS EXISTING <45' SITE IMPERVIOUS MAXIMUM ALLOWED IMPERVIOUS AREA: 50,838 SF (60% OF SITE) CURRENT IMPERVIOUS AREA: 52,597 SF (62% OF SITE) PROPOSED IMPERVIOUS AREA: 49,600 SF (58% OF SITE) PARKING MINIMUM NUMBER OF PARKING SPACES REQUIRED: 113 (5 ACCESSIBLE SPACES) EXISTING NUMBER OF PARKING SPACES: 96 (5 ACCESSIBLE) PROPOSED NUMBER OF PARKING SPACES: 118 (5 ACCESSIBLE) FLOOD ZONE ZONE 'X' SHOWN ON MAP 45013C0461G, DATED 03/23/21 50' ARTERIAL SETBACK LOADING ZONE LIGHTING SCHEDULE SYMB.DETAIL 4/L600 10.1 CALL- OUT 5/L600 10.2 DESCRIPTIONQTY. 2 15 SIGN LIGHT PATH LIGHT NOTE: LIGHTING SYMBOLS ARE GRAPHIC IN NATURE AND ARE NOT INTENDED TO BE TO SCALE. REFER TO SITE DETAILS FOR SIZES AND DIMENSIONS. 13.3EV CHARGING STATION - SEE DETAIL 3/L6001 13.3 13.1TYP. 10.1 10.2 TYP. DITCH SOUTHERN BOUNDARY (240 LF) - WM. HILTON PARKWAY TYPE 'E' OPTION 1 (50') MAJOR ARTERIAL BUFFER EASTERN BOUNDARY (350 LF) - SHARED COMMERCIAL (LC ZONING) PROPERTY LINE NO EXTERIOR BOUNDARY BUFFER REQUIRED WESTERN BOUNDARY (355 LF) - SHARED COMMERCIAL (LC ZONING) PROPERTY LINE NO EXTERIOR BOUNDARY BUFFER REQUIRED NORTHERN BOUNDARY (240 LF) - SHARED COMMERCIAL (LC ZONING) PROPERTY LINE NO EXTERIOR BOUNDARY BUFFER REQUIRED TREE IMPACT LEGEND SYMBOL DESCRIPTION TREE CANOPY - SPECIMEN SPECIMEN TREE IMPACTS - EXISTING SIGNIFICANT TREE IMPACTS - EXISTING NOTE: HATCHES ARE GRAPHIC IN NATURE AND ARE NOT INTENDED TO BE TO SCALE. LOWEST LIMB WITH CLEARANCE FROM GRADE+12' TREE CANOPY - SIGNIFICANT SPECIMEN TREE IMPACTS - PROPOSED SIGNIFICANT TREE IMPACTS - PROPOSED ~~ 11: 'Re $$$ c% a- $°o~0> £ 8 ,-~ 0;"' eso £ 'tl C»ss5 s:::~o.:)3 etAgmg8 3"=,!cl s '+ ?yl&$s3 a {$- 6±~ D-~8 1 % gs0 ;f ~'£0tgQ0 a £03 "' -111111 oooooooo //////////////// /III //// //////////////////////IIIIIIIIII 5.64Ac. N/FGIHOSPITALITYLLC TAXMAP4R520--011--000-0132-0000 (REF.PLATW) \ pg40810 @A22 NLo10 PNLOB10 [,,, I l a I _,.,.... -~i' b) J\.e»•¥,I 11 11 II I I \ I ACCESS&CROSSEASEMENT ERREF.PLATj6) DRAINAGE&UTILITYEASEMENT (PERREF.PLAT#6) LOT4 wRRIIILLC ls20--011-000--0156--0000 RF.PLATj6) ,0T6 BwRRIIILLC l20-011--000--0156-0000 REF.PLAT6) 1012 lNOENTERPRISESINC. l2o--011--000--0154-0000 lkEF.PLAT46) W/IL_L_\AMHILIIrHrnvn+u>••••• 1'p/\W0 L ----- MMMM% MM%2%% ##2#22#% #MM#22%e pf----........ UTILITYEASEMENT (PERREF.PLAT#4) ,UTILITYEASEMENT (PERREE.PLATj4) _____,f---~-ACCE~·-·,,t.ASEMENT~ (ERREF.PLATj4) t--IL, le] [--r.pl ¥ oaiota T=TT7T GE,] I -I -I JI ~-Y I a- f@-tad• r.=LUI E sp47 ' EE}'ll Page 13 of 68 van PLANTING PLAN L500 DRB SUBMITTAL PLAN, NOT FOR CONSTRUCTION DRAWING NUMBER DRAWING TITLE DESIGN CONCEPTS, DRAWING, SHEETS, LOGOS, SPECIFICATIONS, DETAILS, WRITTEN MATERIAL SHALL NOT BE USED OR REPRODUCED IN WHOLE OR IN PART IN ANY FORM WITHOUT PRIOR WRITTEN CONSENT OF WJK LTD. © 2026 WJK LTD. THIS SHEET TO SCALE AT: 24"X36" DATE: PROJECT NO.: DRAWN BY: CHECKED BY: FEB 25, 2026 XXXXX.XX SD JC REVISIONS: SITE DEVELOPMENT PLANS FOR ATRIUM BUILDING HILTON HEAD ISLAND, SOUTH CAROLINA 840 WILLIAM HILTON PARKWAY PLANT KEY LEGEND PLANTING DETAILS DETAIL DESCRIPTION TREE PLANTING14.1 CALL- OUT 14.2 14.3 PALM TREE PLANTING SHRUB PLANTING 14.4GROUND COVER PLANTING 14.5ROOT BARRIER 1/L501 2/L501 3/L501 4/L501 NA PLANTING REFERENCE NOTES: 1EXISTING TREES TO REMAIN. EXISTING TREES TO BE REMOVED. MULCH DISTURBED AREAS DUE TO CONSTRUCTION. ALL PARKING LOT PALM TREES SHALL BE PLACED IN LINE WITH EACH OTHER CENTERED IN THE MEDIAN. CAREFULLY EXCAVATE SHRUB PITS IN VICINITY OF EXISTING TREES, WITHOUT DISTURBING TREE ROOTS. 2 4 3 5 0 20 40 60 80 10 30 50 70 Scale 1 " = 20' c N E W WILLIAM HILTON PARKWAY - US HIGHWAY 278 NORTHERN BOUNDARY (240 LF) - SHARED COMMERCIAL (LC ZONING) PROPERTY LINE 20' ADJACENT USE SETBACK NO EXTERIOR BOUNDARY BUFFER REQUIRED EASTERN BOUNDARY (350 LF) - SHARED COMMERCIAL (LC ZONING) PROPERTY LINE 20' ADJACENT USE SETBACK NO EXTERIOR BOUNDARY BUFFER REQUIRED OVERSTORY TREES: 4 TREES PER 100 LF - 10 TREES REQUIRED (21 EXISTING) UNDERSTORY TREES: 5 TREES PER 100 LF - 12 TREES REQUIRED (12 PROPOSED) EVERGREEN SHRUBS: 20 SHRUBS PER 100 LF - 48 SHRUBS REQUIRED SOUTHERN BOUNDARY (240 LF) - WM. HILTON PARKWAY 50' ADJACENT STREET SETBACK - MAJOR ARTERIAL TYPE 'E' OPTION 1 (50') MAJOR ARTERIAL BUFFER: WESTERN BOUNDARY (355 LF) - SHARED COMMERCIAL (LC ZONING) PROPERTY LINE 20' ADJACENT USE SETBACK NO EXTERIOR BOUNDARY BUFFER REQUIRED BUFFER SUMMARY: SOUTHERN BOUNDARY (240 LF) - WM. HILTON PARKWAY TYPE 'E' OPTION 1 (50') MAJOR ARTERIAL BUFFER (SEE BUFFER SUMMARY) EASTERN BOUNDARY (350 LF) - SHARED COMMERCIAL (LC ZONING) PROPERTY LINE NO EXTERIOR BOUNDARY BUFFER REQUIRED WESTERN BOUNDARY (355 LF) - SHARED COMMERCIAL (LC ZONING) PROPERTY LINE NO EXTERIOR BOUNDARY BUFFER REQUIRED NORTHERN BOUNDARY (240 LF) - SHARED COMMERCIAL (LC ZONING) PROPERTY LINE NO EXTERIOR BOUNDARY BUFFER REQUIRED ATRIUM BUILDING WILLIAM HILTON PARKWAY - US HIGHWAY 278 ADJACENT PARKING ADJACENT PARKING HOME 2 SUITES PROPERTY LINE PROPERTY LINE PROPERTY LINE PROPERTY LINE SIDEWALK DITCH ADJACENT PARKING 20 LIRE 5 LORC 2 MAGV 6 ILLP 9 DISB 1 SABP 1 SABP 65 MUHC 2 SABP 7 DISB 30 LIRE 50 LIRE 1 QUEV 18 PODM 20 LIRE 20 PODM 20 LIRE 1 QUEV 50 TRAA 65 TRAA 1 QUEV 40 LIRE 1 QUEV 40 LIRE 25 LIRE 25 MUHC 40 LIRE 1 SABP 1 MAGV 2 SABP 1 MAGV 5 ILLP 3 DISB 3 LORC 5 ILLP 3 LORC 11 DISB 1 SABP 9 AZAE 5 JUNV 2 JUNV 20 LIRE 1 SABP 3 ILVN 1 SABP 5 SABP 2 SABP 5 SABP 3 QUEV 3 SABP 30 LIRE 2 QUEV 3 ILLP 5 ILVN 9 ILVN 8 ILVN 1 SABM 6 ILVN 5 ILLP 1 QUEV 8 ILVN 2 SABP 20 LIRE 14.2 TYP. 14.1 TYP. 14.4 TYP. 14.3 TYP. 1 2 4 5 50' TYPE 'E' OPTION 1 BUFFER 20' ADJACENT USE SETBACK 20' ADJACENT USE SETBACK 20' ADJACENT USE SETBACK MARINA SIDE DRIVE 8 DISB 5 ILVN 1 SABP 35 LIRE 5 LORC 1 QUEV 14 ILVN20 ILVN 16 ILVN SPECIMEN AND SIGNIFICANT TREE ENCROACHMENT SUMMARY: A B D C E 29 DBH LIVE OAK (SIGNIFICANT TREE) - EXISTING CANOPY IMPACT: 5% PROPOSED CANOPY IMPACT: 5% (NO CHANGE A D C E F G H I G F H I 28 16 17 DBH LIVE OAK (SPECIMEN TREE) - EXISTING CANOPY IMPACT: 21% PROPOSED CANOPY IMPACT: 14% 24 DBH LAUREL OAK (SIGNIFICANT TREE) - EXISTING CANOPY IMPACT: 3% PROPOSED CANOPY IMPACT: 3% (NO CHANGE) 29 DBH WATER OAK (SIGNIFICANT TREE) - EXISTING CANOPY IMPACT: 30% PROPOSED CANOPY IMPACT: 13% 26 DBH LIVE OAK (SIGNIFICANT TREE) - EXISTING CANOPY IMPACT: 65% PROPOSED CANOPY IMPACT: 65% (NO CHANGE) 30 DBH LIVE OAK (SPECIMEN TREE) - EXISTING CANOPY IMPACT: 0%PROPOSED CANOPY IMPACT: 13% 50 DBH LIVE OAK (SPECIMEN TREE) - EXISTING CANOPY IMPACT: 20%PROPOSED CANOPY IMPACT: 20% (NO CHANGE) 25 DBH WATER OAK (SIGNIFICANT TREE) - EXISTING CANOPY IMPACT: 14% PROPOSED CANOPY IMPACT: 14% (NO CHANGE) 32 DBH LAUREL OAK (SPECIMEN TREE) - EXISTING CANOPY IMPACT: 17% PROPOSED CANOPY IMPACT: 17% (NO CHANGE) B 60 TRAA DITCH TREE IMPACT LEGEND SYMBOL DESCRIPTION TREE CANOPY - SPECIMEN SPECIMEN TREE IMPACTS - EXISTING SIGNIFICANT TREE IMPACTS - EXISTING NOTE: HATCHES ARE GRAPHIC IN NATURE AND ARE NOT INTENDED TO BE TO SCALE. LOWEST LIMB WITH CLEARANCE FROM GRADE+12' TREE CANOPY - SIGNIFICANT SPECIMEN TREE IMPACTS - PROPOSED SIGNIFICANT TREE IMPACTS - PROPOSED ~~ 11: 'Re c% a-o~0> £ 8-~ 0;"' o £ 'tl5 )3 mg8 ,!cl '+s $s3 $ a-~ ~8 %£30 ;f £0tgQ0 a £03 "' l PinkMuhlyGrass SweetbayMagnolia DwarfPalmetto EvergreenGiantLiriope AsiaticJasmine EncoreAzalea BlueCascadeDistylium DwarfYauponHolly YellowAnise EverRedFringeFlower Podocarpus Magnoliavirginiana Sabalminor Muhlenbergiacapillaris Azaleaxencore Distylium'BlueCascade'(PIIDISTAI PP24409) lexvomitoria'Nana' llliciumparviflorum Loropetalumchinense'ChangNian Hong Podocarpusmacrophyllus TRAA UNDERSTORYTREES MAGV SABM l GROUNDCOVERS,VINES&PERENNIALS LIRELiiriopemuscari'EvergreenGiant Trachelospermumasiaticum ORNAMENTALGRASSES&FERNS MUHC SHRUBS AZAE DISB ILVN ILLP LORC PODM AbbrevB0LADiaLNamommOnNam TREES JUNVJuniperusvirginiana OUEV EasternRedCedar SABP OuercusvirginianaLiveOak SabalpalmettoCabbagePalm ooooo ooooooooo MM%MM% MM%MM% #####e #MM%%e -- -- ----- /////////////////7///IIIIII > \ ( Ae co A) I Ae }A" \ UTILITYEASEMENT J1 1(PERREFPLAT1•) 1 I A22 PNLO10 O o M40810 PNLO10 TILITYEASEMENT ERREF.PLAT#4) PNLOB [,,., DRAINAGEEASEMENT (PERREF.PLATj4) -- ,UTILITYEASEMENT (PERREF.PLAT#4) -7--~-----UTILITY EASEMENTS~,(PERREF.PLAT#4) SSss SSH "SSSSSSS 10•PVCINIE•9.29 ~ 1o•PVCINIE•9.26 J [)1"Pvc_our_1E-9.1s (g]rI]\unurEAsuNr Iii.L_(PER_: PLAT l•)l__t---- ,3i] a I Ae I A" I Ae I Ae I «99 s..89¢ -" ~ [·0]. -{~V ~ p' ]ACCESS&UTILITYEASEMENT (PERREF.PLATj4) >I EASEMENT.(PERREF PAT +), )l APHALTBIKEPAT SDSD o5Ac.@ 0 ,T.BM._NAIL_SETIN i5·coox7-\{'-, ELEvns=17.00 NAVD88DATUM I ¥ E E3 (E) ¥l ~T]--_,,_, TOPOFBANK !ill 123.4' ead%#$ \{o \0O $zCloO O - •LA32 !! LA2212 ~LO6 .J_ »"",A=4l4l±l »k#t!". i* a\22 $iij] KP]; ?r'•wot#igl; Eiltsnr=ag 1-,"WE" COVERED,9CY11 GSib4]s] l#±:•t --!+<J I Pul16 ¥ -CENTERLINEDITCH -----~~~':5s_»---2:::,;:;;::::::::___~L__'.;~ ---~-- Qroor• \ Page 14 of 68 PLANT SCHEDULE AND DETAILS L501 DRB SUBMITTAL PLAN, NOT FOR CONSTRUCTION DRAWING NUMBER DRAWING TITLE DESIGN CONCEPTS, DRAWING, SHEETS, LOGOS, SPECIFICATIONS, DETAILS, WRITTEN MATERIAL SHALL NOT BE USED OR REPRODUCED IN WHOLE OR IN PART IN ANY FORM WITHOUT PRIOR WRITTEN CONSENT OF WJK LTD. © 2026 WJK LTD. THIS SHEET TO SCALE AT: 24"X36" DATE: PROJECT NO.: DRAWN BY: CHECKED BY: FEB 25, 2026 XXXXX.XX SD JC REVISIONS: SITE DEVELOPMENT PLANS FOR ATRIUM BUILDING HILTON HEAD ISLAND, SOUTH CAROLINA 840 WILLIAM HILTON PARKWAY 1L501TREE PLANTING SCALE: N.T.S.2L501PALM TREE PLANTING SCALE: N.T.S. 3L501SHRUB PLANTING SCALE: N.T.S.4L501GROUND COVER PLANTING SCALE: N.T.S.5L501TREE STAKING SCALE: N.T.S. PLANT SCHEDULE: PLANT TABLE: BLACK RUBBER HOSE 120° 120° 120° PLAN DOUBLE STRAND 12 GAUGE WIRE PROTECT TREE TRUNK WITH BLACK RUBBER HOSE OR APPROVED EQUAL DOUBLE STRAND 12 GAUGE WIRE WITH GALVANIZED TURNBUCKLE OR APPROVED EQUAL. MARK AS HAZARD IN LOCATION WITH HIGH PEDESTRIAN TRAFFIC 3" MINIMUM MULCH DEPTH, REFER TO PLANT SCHEDULE FOR TYPE SOIL BERM TO HOLD WATER TREE 2"X4" STAKES (36" LONG) BURIED BELOW FINISH GRADE - ENSURE STAKES ARE MARKED TO SIGNIFY HAZARD IN LOCATIONS WITH HIGH PEDESTRIAN TRAFFIC FINISH GRADE B&B OR CONTAINERIZED (REFER TO PLANT SCHEDULE) SCARIFY SIDES OF HOLE TO 4" DEPTH MINIMUM AMENDED PLANTING SOIL AS NEEDED PER SOIL ANALYSIS COMPACT PLANTING SOIL BENEATH ROOTBALL NOTES: 1. TREE STAKING OPTIONAL, HOWEVER, LANDSCAPE CONTRACTOR RESPONSIBLE FOR MAINTAINING TREES IN AN UPRIGHT (90 DEGREE/ PERPENDICULAR) POSITION FOR 1 YEAR AFTER PLANTING IS COMPLETE OR UNTIL TREE ROOT SYSTEM IS FULLY ESTABLISHED AND STURDY. FINAL TREE STAKING DETAILS AND PLACEMENT TO BE APPROVED BY OWNER'S REPRESENTATIVE. 2. CONTRACTOR SHALL ASSURE PERCOLATION OF ALL PLANTING PITS PRIOR TO INSTALLATION. 3. IN SEMI-IMPERVIOUS SOIL CONDITIONS, ROOTBALL ELEVATION SHALL BE 2" ABOVE FINISH GRADE. COORDINATE WITH OWNER'S REPRESENTATIVE PRIOR TO SETTING ROOTBALL ELEVATIONS. 12" TYP. 12" MIN. DOUBLE SIZE OF ROOTBALL, TYP. CLEAR TRUNK, REFER TO PLANT SCHEDULE COMPACTED SUBGRADE AMENDED PLANTING SOIL AS NEEDED PER SOIL ANALYSIS 3" MINIMUM MULCH DEPTH, REFER TO PLANT SCHEDULE FOR TYPE FINISH GRADE SOIL BERM TO HOLD WATER MAINTAIN TREE IN A PLUMB UPRIGHT POSITION TRUNK OF PALMETTOS SHALL BE NEARLY UNIFORM IN SIZE OVER ENTIRE HEIGHT AND SHALL BE FREE OF OLD FROND STUBS, FIRE BLACK AND OTHER DAMAGE REFOLIATED PALMETTO NOTES: 1. FINAL TREE STAKING DETAILS AND PLACEMENT TO BE APPROVED BY OWNER OR OWNER'S REPRESENTATIVE, 2. CONTRACTOR SHALL ASSURE PERCOLATION OF ALL PLANTING PITS PRIOR TO INSTALLATION. 3. SABAL PALMETTOS SHALL BE REFOLIATED, PROTECT CABBAGE HEAD FROM DAMAGE. NOTES: 1. WHEN GROUNDCOVERS AND SHRUBS ARE USED IS MASSES, ENTIRE BED TO BE EXCAVATED TO RECEIVE PLANTING SOIL AND PLANT MATERIAL. 2. CONTRACTOR SHALL ASSURE PERCOLATION OF ALL PLANTING PITS PRIOR TO INSTALLATION. 3. IN SEMI-IMPERVIOUS SOIL CONDITIONS, ROOTBALL ELEVATION SHALL BE ±2" ABOVE FINISH GRADE. COORDINATE WITH OWNER'S REPRESENTATIVE PRIOR TO SETTING ROOTBALL ELEVATIONS. 4" TYP. DOUBLE SIZE OF ROOTBALL, TYP. AMENDED PLANTING SOIL AS NEEDED PER SOIL ANALYSIS B&B OR CONTAINERIZED (SEE PLANTING SCHEDULE, THIS SHEET) FINISH GRADE SOIL BERM TO HOLD WATER 3" MINIMUM MULCH DEPTH, REFER TO PLANT SCHEDULE FOR TYPE -- - SPECIFIED O.C. SPACING NOTE: 1. EXCAVATE ENTIRE BED SPECIFIED FOR GROUNDCOVER PLANTING TO A DEPTH OF 12" TYPICAL EDGE OF PLANT BED 1/2 OF SPECIFIED O.C. SPACING SPECIFIED O.C. SPACING ATYPICAL SPACING IN CURVILINEAR PLANT BEDS. OUTSIDE ROW TO FOLLOW CURVE AS SHOWN ON PLAN ±5' DIA. 3" MINIMUM MULCH DEPTH, REFER TO PLANT SCHEDULE FOR TYPE SMOOTH CONTINUOUSLY CUT EDGE TYPICAL TREE TREE STAKE NOTES: 1. APPLY MULCH IN A ±5' DIAMETER WHERE PROPOSED TREE PLANTINGS OCCUR IN SOD OR SEEDED AREAS. CAT. I AND CAT. II TREE MITIGATION SATISFIED BY PLANTING OF 10 LIVE OAKS (QUEV) SEE PLANT SCHEDULE - CAT. II MITIGATION SATISFIED BY PLANTING OF 21 SABAL PALMETTO (SABP) SEE PLANT SCHEDULE - NOTE: * ** *** ~~ 11: 'Re $$$ c% a- $°o~0> £ 8 ,-~ 0;"' eso £ 'tl C»ss5 s:::~o.:)3 etAgmg8 3"=,!cl s '+ ?yl&$s3 a {$- 6±~ D-~8 1 % gs0 ;f ~'£0tgQ0 a £03 "' ContainerCal/spacing Spread commonName JUNVJuniperusvirginianaEasternRedCedar6'823Cont.Fulltoground OUEVOuercusvirginianaLiveOak14-16'68Cont.4"Full SABPSabalpalmettoCabbagePalm12-16Cont.Refoliated,fullcleartrunk, refertoplanforheights Abbrev Quantity TREES 7 11 28 -- UNDERSTORYTREES a4MAGVMagnoliavirginianaSweetbayMagnolia8-1O4530gal.Full 3SABMSabalminorDwarfPalmetto45'4-515gal.Full SHRUBS 9AZAEAzaleaxencoreEncoreAzalea24-3024-307gal.Full 38DISBDistylium'BlueCascade'(PIIDIST-II BlueCascadeDistylium24-3024-307gal.Full --I PP24409) tr89ILVNllexvomitoria'Nana'DwarfYauponHolly18-241824°7gal.Full 24ILLPllliciumparviflorumYellowAnise30-3624-307gal.Full #tit16LORCLoropetalumchinense'ChangNianEverRedFringeFlower30-3624307gal.Full -Hong' 38PODMPodocarpusmacrophyllusPodocarpus18-24247gal.Full Full Full Full CAT.ICAT.IICAT.IllCAT.ICAT.ICAT.Ill SpeciesAbbrev.LOLAWOPLMPNLOB#OFTREESTOBEREMOVED5118 CaliperInches1418152210 201710TOTAL#OFDBHINCHES8315205 171410 141110CALCULATION83+10=8.315+10=1.5205+10=20.5 1110#OFNEWTREESREQUIRED8221 1410 610#OFNEWTREESPROVIDED8221 10 10 10 10 SpeciesDBHTotals14691595110 TotalDBHInchesPerCAT8315205 TREELEGEND:LO-LiveOak,LA-LaurelOak,WO-WaterOak,PLM-Palmetto,PNLOB- Loblolly_Pine ORNAMENTALGRASSES&FERNS 90MUHCMuhlenbergiacapillarisPinkMuhlyGrass14-1610-16°1gal.300.C GROUNDCOVERS,VINES&PERENNIALS 350LIRELiriopemuscari'EvergreenGiantEvergreenGiantLiriope12-168-12°1gal.240.C l175TRAATrachelospermumasiaticumAsiaticJasmine46°I2"runnersIgal.180.C II ,, y~ > 7! ,,% ,, , , II 3-,lE},b_!,r{'}d ts}Age_gee./[j[' Him#et=][1II ,, ' J M.\ r ±a ---raa ',',.' \ \ ~----.,,,..,"I,.., w .el,, _i ,, II ]+] ''.+'.. ,· . ·+·•. ·.•· I . , ..-. ·r . ·1• .., =0• -E+ I+I a ',4++++++]Z '-.. ,, , , %¢ FjmuRyff IE4».EIF .LI7 iitti-,J -di7nine} [ ]][l]I IIIIII Page 15 of 68 DRB SUBMITTAL PLAN, NOT FOR CONSTRUCTION DRAWING NUMBER DRAWING TITLE DESIGN CONCEPTS, DRAWING, SHEETS, LOGOS, SPECIFICATIONS, DETAILS, WRITTEN MATERIAL SHALL NOT BE USED OR REPRODUCED IN WHOLE OR IN PART IN ANY FORM WITHOUT PRIOR WRITTEN CONSENT OF WJK LTD. © 2026 WJK LTD. THIS SHEET TO SCALE AT: 24"X36" DATE: PROJECT NO.: DRAWN BY: CHECKED BY: FEB 25, 2026 XXXXX.XX SD JC REVISIONS: SITE DEVELOPMENT PLANS FOR ATRIUM BUILDING HILTON HEAD ISLAND, SOUTH CAROLINA 840 WILLIAM HILTON PARKWAY L600 SITE DETAILS 3L600ELECTRIC VEHICLE CHARGING STATION SCALE: NTS 1L600CONCRETE SIDEWALK SCALE: 1" - 1'-0"2L600BRICK PATIO / SEATING AREA SCALE: 1" - 1'-0" 4" 6" CONCRETE WALK WITH 6X6 10-10 W.W.M. FINISHED GRADE COMPACTED SUBGRADE EXISTING SUBGRADE NOTES: 1. PROVIDE 1% MIN, 2% MAX. CROSS SLOPE ON ALL PAVED SURFACES FOR POSITIVE DRAINAGE. 2. REFER TO PLAN (SHEET L200) FOR WIDTHS OF WALK. 3. CONSTRUCT EXPANSION JOINTS WHERE WALK MEETS CURBS, STEPS, WALLS OR FIXED SLABS. 4. CONTROL JOINTS TO BE 5' O.C., TYP. CONTROL JOINTS TO BE ADJUSTED IN FIELD AS NECESSARY. SECTION A-A' PLAN A A' WIDTH VARIES CONCRETE WALK EXPANSION JOINT CONTROL JOINT CONCRETE INFORMATION: CONCRETE: 3,000 P.S.I. AT 28 DAYS FINISH: LIGHT BROOM FINISH SOIL INFORMATION: SOIL COMPACTION: 95% STANDARD PROCTOR HAND TIGHT / BUTT JOINTED NOTES: 1. PROVIDE 1% MIN., 2% MAX. CROSS SLOPE ON ALL PAVED SURFACES FOR POSITIVE DRAINAGE. 2. REFER TO PLAN (SHEET L200) FOR WIDTHS OF WALKS AND LOCATION OF BRICK BORDERS. 3. CONTRACTOR SHALL COORDINATE BORDERS AND PATTERN WITH OWNER'S REPRESENTATIVE PRIOR TO CONSTRUCTION. 4. UPON REQUEST, CONTRACTOR SHALL PROVIDE 4'X4' PAVING PANELS OF ALTERNATIVE COLORS PRIOR TO CONSTRUCTION FOR APPROVAL BY OWNER OR LANDSCAPE ARCHITECT. BRICK MANUFACTURER INFORMATION: MANUFACTURER: LOWCOUNTRY PAVER BRICK: HYDRASHED PERMEABLE PAVER COLOR: BATTERY GREY WITH TABBY FINISH; BONFIRE PAVER BORDER PATTERN: HERRINGBONE FIELD (REFER TO PLAN, SHEET L200, FOR DIRECTION) WITH SINGLE HEADER COURSE BORDER JOINTS: HAND TIGHT CRUSHED STONE 4" 5" 8" BRICK FIELD, TYP. BRICK BORDER, TYP. SAND SETTING BED PER MANUFACTURER'S SPECIFICATIONS CONCRETE BASE COMPACTED AGGREGATE BASE COMPACTED SUBGRADE EXISTING SUBGRADE 6" MORTAR, TYP. BRICK FIELD, TYP. BRICK BORDER, TYP. HAND TIGHT / BUTT JOINTED WITH SAND SWEPT JOINTS 45° CUT AT INTERSECTIONS, TYP., CUT ALL BRICK FROM FULL, TYP. ADJACENT MATERIAL VARIES, REFER TO PLANS PLAN SECTION A-A' AA' OTHER INFORMATION: CONCRETE: 3,000 P.S.I. AT 28 DAYS SOIL COMPACTION: 95% STANDARD PROCTOR FINISHED GRADE 4L600SIGN LIGHT SCALE: NTS5L600PATH LIGHT SCALE: NTS 6L600BIKE RACK SCALE: NTS EXAMPLE INSTALLATION SUPPLIER: ULINE (ULINE.COM 1-800-295-5510) COLOR: BLACK ~~ 11: 'Re $$$ c% a- $°o~0> £ 8 ,-~ 0;"' eso £ 'tl C»ss5 s:::~o.:)3 etAgmg8 3"=,!cl s '+ ?yl&$s3 a {$- 6±~ D-~8 1 % gs0 ;f ~'£0tgQ0 a £03 "' 5-L0OP •Mountinghardwareincluded. •23/8"diameterbar. •Forstadiums,parksand athleticfields. Upscalestylishlook.Easytosecureyourbike. 3-LOOP I-- WAVEBIKERACKSGovanaedBlackGreen MODELSIZEBIKEwT.PRICEEACHADDTO DESCRIPTIONNO.LxWxHCAPACITYLs.)13+CART H-2892I-Loop22x2/2x34327$230$220SpecifyColor •H-25433loop43x2/2x39"556395375SpecifyColor [zisee68x2/2x39"780515495SpecifvColor I dl7anted'andBl6dkonly·Sil#sAT7otd#T#tel6kl •10-gaugegalvanizedsteelor attractivepowdercoating. WAVEBIKERACKS V / ¥Ir,¥III¥ALIKA¥It¥I/III¥Kt¥Kt¥t/At¥Alt¥tt/At¥ttttt¥AA¥I II •0 . •0 .1,11.,1,,1,,1,,1 •_ ° ITl Gd"NIT­ II.II±IIII 1IE[IE[IIpl H EE;A3LEE,EE39Ee.4.g3I ..I.,.·. ·11·r1j·. •I,lj ·l'j::11•r1I•1·111 #±%9±@±3.pt,EL£±Cg i%l[$$if#its<j##ifii#pl.if%#$iii$$%ii} £9±£]@2$,j±@±£ 9.E7IEEE2.7%peg#.2q@e@%%5f%#i%%fie%ti%$£.$1$f%% H- II II DB@?ZEV/erevanea«oeI ~nrr00 gas0 Iti.a l IEE 10 MM4.NiteLitesSustainableOutdoorLEDs 30-40 SustainableCostEffectiveMaintenanceFree EEETTI Iq; Designedtoprovidesafetyanddirectionaroundpoolareas, sidewalks,driveways,andsteps.Alsousedtohighlightlowground cover.Idealforresidentialandcommercialgardensettings. EESEMODEL:SOPBOLLARD FINISH:AgedBrass ELECTRICAL:12V GLASS:Frosted LED:4W COLORTEMP:3000K SOCKET:Bi.Pin RATED:40,000Hours PRODUCTSPECIFICATIONSHEET EZEIATEI I.asla l % [ti I '" 8 -l o)» t :t 41w4 V'to rn5 3 osCOMMERCIALSTAKE. NITE.124A EIIEII ,SURFACEMOUNT: >NTE-5I0 MOUNTINGACCESSORIES: RISERS: 6°NITE-520 -12NITE52I r 18"NITE-522 sas ..-~ II Adjustable Knuckle NITE.-434 •EnergySavings-4Walls •Color:WarmWhite •ColorTemp:2700K •luminousFlux:296--316lm Groundstake 4488nee l E3EITEL NITE-046 Commercial N.. ~'\~~~ '"""' lI~ »,[.4)ueurtingetimpovt out Ir,•f0f9 Ii'I~'i"~\,'(efJ~y[,sIfL),Li,,J[Ji,,,v ""FifG5ii lheh,[ssot'wl[ MMANitelites'-SustainableOutdoorLEDs GRADE: MODEL: SustainableCostEffectiveMaintenanceFree MOUNTING:1/2"NPT FINISH:AgedBrass SOCKET:AllWeatherCeramicBi-Pin ELECTRICAL:12V LED:4WModule PRODUCTSPECIFICATIONSHEET- EE"TETI7EalSolidBrass,heavydutyfixturewithadjustableknuckle. Fixturewillwashsmallplants,hedgerows,andsmall architecturalfeatures. mI auNoht cut.NtLt#Atottc.tot »48A/11.2kmoxoutput,anbe adjustedto404,32A4,or24 »Sleek,compact,tuggedhousing,for indoor&outdooruse •MounttoawallorbreezEVpedestal. ledudesconnectorholster&cablehook, 1rablewtJ1772connector& incomingpwecordw'NEMA14.50plug +j1772connectorattachestothebottom oftheunitorcanbemountedseparately. »ChargeusesNEMA1450plugorcan behardwired Groundfaultcircuitinterrupter(GFCI) includedforsafeandeasywiring vL2AccoALFMGatroPDtstutwuprTaros tvL2at.coAtMGMTroPEDtSTLw/+prRu.TOR tvCA?AwCutttArowusvwoto#AboTETt tv42AC€C$RACKET#ORSOtSDt0#ts r1 N£ox _)re«tveo • Pots1ui$/arsoms ughtEIicientDesign Simplyplugandcharge.Mointernetconnectionorsoftwarerequired Offeringupto48A4chargingpowerandaretheperfectEVehaging solutionforresidentialandcommercialapplications.Pedestalsand mountingoptionsareallmadeintheUSA, LightEfficientDesign tLcrmcuPortcnosuor uNotvotaGtorvot1Atsotconcur Su0GtPROTEC.ToNOVERtruwt uto«eAstn] NA $arot$tMoun,Kt RtUDOORMOUNNGON OWEPFOSIMAKIT+ORL?€HAGA wtcoNorAN.hoKut 3»#ai:Mre- 9..•kWIP5K08> %taro itnoto.-~-vettre ALL4.ONtKIT0NCUDE$CO-AGARwr#1,A,4ACALE) ii_beezv i L-1- • vct2s4a1t orcurttsputcut.NT VA2ACMAKEREADYASECHARGINGSTATIONFOUNDATION rv4?A.APKa rv2AsPK "zE-"E3E:.7MEL.3CI7TIC7TIE:ET3EESJ lootit r.rpm _DB?EV[ow»sos+«oorowawro II IIII Page 16 of 68 A R CH ITECT S A R CH ITECT S parkerdesigngrouparchitects 843 785 5171 POST OFFICE BOX 5010 HILTON HEAD ISLAND SC 29938 A RENOVATION FOR : REVISIONS DATE OF ISSUE: TP SHEET OF SHEETS TP SCALE DRAWN BY CHECKED BY JOB NO. 2/25/26 HILTON HEAD , S.C. SERG GROUP THE ATRIUM BUILDING These documents & designs are the property of Parker Design Group | Architects & are not to be used or reproduced there of or for designs, working drawings, or construction of buildingswithout the written authorization from the copy write owner PDG|Architects 2024 copyright C 8" 2" 10" 10'-2" +- 8'-0"10'-2" 15'-0" 6'-0" 20'-0" 31'-2" 3'-8" 25'-0" 3'-8" 2'-0" 5 1/2" KITCHEN EXISTING RISER EXISTING ELECT. EXISTING ELEV. EXISTING ELEV. EQUIP. RETAIL 49-0" X 40'-0" CHECK OUT TASTING/ MEETING BRIDE'S SUITE OFFICE #1 OFFICE #2 12'-2" X 10'-4" OFFICE #4 OFFICE #3 OFFICE #6 11'-6" X 10'-4" OFFICE #5 11'-6" X 10'-4" 15'-0" X 24'-0" EVENT SPACE #1 48'-0" X 39'-6" 9'-0" X 19'-0" EXISTING WOMENS EXISTING MENS NEW (2) STORY ENTRANCE DW UP WATERFALL WALL DELIVERY ENTRANCE UP 12'-2" X 10'-4" 12'-2" X 10'-4" 12'-2" X 10'-4" NEW STOREFRONT NEW STOREFRONT EXISTING STAIRCASE HOT FOOD SERVING COUNTER BLAST CHILLER FREEZER DISPLAY CASE CONVECTION OVEN CONVECTION OVEN FRYERFRYER GRIDDLE CHARBROILER TILTING SKILLET TILTING SKILLET KETTLE KETTLE RANGE (2) BAKING OVEN MIXER 1 MIXER 2 SANDWICH/ SALAD PREP. REF. REACH IN FREEZER REACH IN FREEZER WORK TABLE WORK TABLE WORK TABLE (3) COMPARTMENT SINK ROTISSERIE OVEN WIRE SHELVING WIRE SHELVING WIRE SHELVING WIRE SHELVING WIRE SHELVING WIRE SHELVINGWIRE SHELVING WIRE SHELVING WIRE SHELVING (2) COMPARTMENT SINK WORK TABLE WORK TABLE WORK TABLE WIRE SHELVING WIRE SHELVING WORK TABLE WORK TABLE WORK TABLE WORK TABLE WORK TABLE WORK TABLE WORK TABLE WORK TABLE WIRE SHELVING WIRE SHELVING WIRE SHELVING WIRE SHELVING WORK TABLE SOILED DISHTABLEDWCLEAN DISHTABLE REACH IN REF. WORK TABLE WORK TABLE REACH IN REF. SANDWICH/ SALAD PREP. REF. WALK IN COOLER WORK TABLE (2) COMPARTMENT SINK NEW COOLER ELEV. NEW SERVICE YARD 24'-0" X 15'-0" 1 A.2.5 BUILDING SECTION BUILDING SECTION 2 A.2.5 1 A.2.5 2 A.2.5 BUILDING SECTION 1 A.2.6 1 A.2.6 GROOM'S SUITE 12'-0" X 20'-0" BLACK OUT GLASS BENCH BENCH CHANGING ROOM CHANGING ROOM MOP SINK BUILDING SECTION 2 A.2.6 2 A.2.6 REPAIR AND REPAINT EXISTING GUARD W/ NEW HANDRAIL 1 A.3.1 2 A.3.1 3 A.3.1 2 A.3.2 1 A.3.2 3 A.3.2 2 A.3.3 1 A.3.3 12 3 24 25 5 4 8 21 20 17 16 14 15 12 13 23 22 19 18 11 10 6 7 9 A B B C D E E 3 A.3.2 5 A.3.4 DEMO WALLS DEMO WALLS DEMO WALLS DEMO WALLS DEMO STAIRS DEMO WALLS AND STAIRS A.1.1 FIRST FLOOR PLAN SCALE: 1/8" = 1'-0" 2 A.1.1 DEMO PLAN SCALE: 3/32" = 1'-0" 1 A.1.1 Page 17 of 68 A R CH ITECT S A R CH ITECT S parkerdesigngrouparchitects 843 785 5171 POST OFFICE BOX 5010 HILTON HEAD ISLAND SC 29938 A RENOVATION FOR : REVISIONS DATE OF ISSUE: TP SHEET OF SHEETS TP SCALE DRAWN BY CHECKED BY JOB NO. 2/25/26 HILTON HEAD , S.C. SERG GROUP THE ATRIUM BUILDING These documents & designs are the property of Parker Design Group | Architects & are not to be used or reproduced there of or for designs, working drawings, or construction of buildingswithout the written authorization from the copy write owner PDG|Architects 2024 copyright C 20'-6" 6" 10'-6" 2'-6"6'-2 1/2" 4'-6"6'-0"5'-0" 4'-0" 9'-5" 9'-3" 9'-5" 9'-3" 9'-5" 5'-6" 9'-5" 5'-0" 9'-5" 5'-0" 9'-5" 5'-6" +- 4'-6" +- 9'-5" 5'-0" 9'-5" 5'-0" 9'-5" 5'-6" 10'-2" 8'-6" 20'-8" 9'-3" 9'-5" 9'-3" 9'-5" 9'-3" 9'-5" 20'-8" EVENT SPACE #3 79'-0" X 53'-0" 188 SEATS EVENT SPACE #2 48'-0" X 73'-0" 172 SEATS DANCE FLOOR 28'-0" X 20'-0" DANCE FLOOR 27'-0" X 25'-0" TABLES & CHAIRS 25-6" X 17'-0" CATERING KITCHEN 37'-9" X 17'-0" WOMENS OUTDOOR SPACE 50'-0" X 20'-0" OPEN TO BELOW DN LINE OF (2) STORY ATRIUM LINE OF (2) STORY ATRIUM FOLDING WALL EXISTING ELEV. EXISTING STAIRCASEDNBUFFET BUFFET HEAD TABLE HEAD TABLE MENS WORK TABLEWORK TABLE WORK TABLEWORK TABLE SOILED DISHTABLE DW CLEAN DISHTABLE WIRE SHELVING WIRE SHELVING HEATED BANQUET CART 2 HEATED BANQUET CART 2 REACH IN REF. HEATED BANQUET CART 1 HEATED BANQUET CART 1 REACH IN REF. STORAGE 10'-0" X 17'-0" ELEV. 1 A.2.5 BUILDING SECTION BUILDING SECTION 2 A.2.5 1 A.2.5 2 A.2.5 BUILDING SECTION 1 A.2.6 1 A.2.6 GIFT TABLE BUILDING SECTION 2 A.2.6 2 A.2.6 2 A.3.3 1 A.3.3 2 A.3.2 1 A.3.2 3 A.3.2 1 A.3.4 2 A.3.4 3 A.3.4 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 F G G H H I I J K WINDOW ABOVE WINDOW ABOVE K WINDOW ABOVE L WINDOW ABOVEM MWINDOW ABOVE WINDOW ABOVEM MWINDOW ABOVE WINDOW ABOVEN NWINDOW ABOVE 4 A.3.4 DEMO ALL EXISTING WALLS ON THIS FLOOR DEMO EXISTING STAIRS DEMO EXISTING STAIRS DEMO FLOOR IN THESE SECTIONS DEMO COLUMNS A.1.2SECOND FLOOR PLAN SCALE: 1/8" = 1'-0" 2 A.1.2 SECOND FLOOR DEMO PLAN SCALE: 3/32" = 1'-0" 1 A.1.2 Page 18 of 68 A R CH ITECT S A R CH ITECT S parkerdesigngrouparchitects 843 785 5171 POST OFFICE BOX 5010 HILTON HEAD ISLAND SC 29938 A RENOVATION FOR : REVISIONS DATE OF ISSUE: TP SHEET OF SHEETS TP SCALE DRAWN BY CHECKED BY JOB NO. 2/25/26 HILTON HEAD , S.C. SERG GROUP THE ATRIUM BUILDING These documents & designs are the property of Parker Design Group | Architects & are not to be used or reproduced there of or for designs, working drawings, or construction of buildingswithout the written authorization from the copy write owner PDG|Architects 2024 copyright C 1 2 3 FRAMEDOOR Mat.Material / Finish Type REMARKS/ MANUF.Size MARK FIRE RATING TW H Jamb depth NA8'-0" DOOR & FRAME SCHEDULE 1 Hardware NOTE: 1. PROVIDE TEMPERED GLASS NOTED IN ELEV. KEYS 2. PROVIDE CLOSERS AT ALL RATED DOORS 3. PROVIDE ARMOR SYSTEMS KEVLAR PANELS FOR DOORS #35 & 38 4 5 NA NA3'-0" 8'-0" NA NA 6 7 8 9 10 11 12 13 14 15 6'-0" ALUM. METAL ALUM. METAL METAL METAL METAL 16 METAL 2 METAL METAL 17 18 19 20 21 22 23 24 25 6'-0" 8'-0" 3'-0" 8'-0" 1 3/4" 3 METAL METAL METAL METAL NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA ALUM. 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 6'-0" 7'-0" 30'-0" 10'-0" 6'-0" 7'-0" 1 3/4" 3'-0" 7'-0" 1 3/4" 3'-0" 7'-0" 1 3/4" 3'-0" 1 3/4" 3'-0" 1 3/4" 3'-0" 1 3/4" 6'-0" 7'-0" 45'-0" 10'-0" 3'-0" 7'-0" 30'-0" 4'-6" ALUM. WOOD ALUM. WOOD WOOD WOOD WOOD WOOD WOOD WOOD ALUM. 8 7 12 10 11 7 10 9 10 10 10 10 10 METAL ALUM. METAL METAL METAL METAL METAL METAL NA NA NA NA NA NA NA NA NA NA NA NA NA NA A B TYPE MFG. NUMBER SIZE REMARKSMARK EXISTING R.O. WINDOW SCHEDULE STOREFRONT 1. ALL GLAZING TO 1" CLEAR LOW "E" FOR EXTERIOR WINDOWS- SEE SPECS 2. ALL EXTERIOR STOREFRONT TO BE IMPACT RESISTANT- SEE SPECS 9'-2" X 11'-0" C D E 6'-0" X 6'-6" METAL METAL METAL NAMETAL NAMETAL NAMETAL NAMETAL ALUM. F 9'-2" X 10'-0" WOOD G H I J K M N O ALUM. ALUM. 1ALUM. ALUM. 3'-0" 8'-0" 1 3/4" 3WOOD 3'-0" 8'-0" 1 3/4" 3WOOD 3'-0" 8'-0" 1 3/4" 3WOOD 3'-0" 8'-0" 1 3/4" 3WOOD 6'-0" 8'-0" 1 3/4" 4WOOD 3'-0" 8'-0" 1 3/4" 3WOOD 3'-0" 8'-0" 1 3/4" 3WOOD 3'-0" 8'-0" 1 3/4" 3WOOD 3'-0" 8'-0" 2ALUM. ALUM.3'-0" 8'-0" 2ALUM. 3'-0" 8'-0" 1 3/4" 3WOOD 3'-0" 8'-0" 1 3/4" 3WOOD 3'-0" 8'-0" 1 3/4" 5WOOD 3'-0" 8'-0" 1 3/4" 5WOOD 3'-0" 8'-0" 1 3/4" 5WOOD 3'-0" 8'-0" 1 3/4" 5WOOD 3'-0" 8'-0" 1 3/4" 5WOOD 3'-0" 8'-0" 1 3/4" 5WOOD ALUM.3'-0" 8'-0" 2ALUM. 3'-0" 8'-0" 2WOOD1 3/4" 3'-0" 8'-0" WOOD1 3/4" 6 FIRST FLOOR SECOND FLOOR ALUM. ALUM. 3'-0" 7'-0" 1 3/4" WOOD 10 METAL 7'-0" 7'-0" 7'-0" 7'-0"3'-0" 1 3/4" 1 3/4" WOOD 9 1 3/4" WOOD 6'-0" 7'-0" METAL ALUM. METAL STOREFRONT STOREFRONT STOREFRONT STOREFRONT STOREFRONT STOREFRONT STOREFRONT STOREFRONT STOREFRONT STOREFRONT STOREFRONT STOREFRONT STOREFRONT EXISTING R.O. EXISTING R.O. 9'-2" X 10'-0" 9'-2" X 7'-6" 9'-2" X 7'-6" 12'-0" X 10'-0" 24'-10" X R.O. R.0. X 18'-8" R.0. X 18'-8" R.0. X 12'-6" 8'-0" 3'-0" 3'-0" 8'-0" 6'-2" 18'-0" 3'-0" 7'-0" 7'-0" 6'-0" 2" 2'-11" 2" 2" 2'-11"6'-0" 2" 2" 2'-8"8'-0" 2"2" 2'-8"7'-0" 2" 10'-0" 30'-0" 10'-0" 45'-0" 2'-6" 7'-6" 30'-0" 11'-2" 9'-2" 2" 6'-0" 2" 2'-8" 2" 2" 7'-10" 2" 2'-8" 2" 11'-0" 8'-0" EXISTING HEADER AND SILL EXISTING R.O. EQUAL EQUAL EQUAL EXISTING R.O. EXISTING R.O. 3'-0" 4'-0" 3'-0" 3'-6" 6'-6" 2" 4'-4" 2" 1'-8" 2" 6'-0" 2" 3'-8" 2" 1'-10" 2" 9'-2" 2" 6'-0" 2" 2'-8" 2" 10'-0" 2" 2'-2" 2" 7'-4" 2" 2" 2'-8" 2" 6'-0" 2" 9'-2" 9'-2" 2" 6'-0" 2" 2'-8" 2" 2" 2'-2" 2" 7'-4" 2" 10'-0" 2'-6" 2" 4'-4" 2" 2'-8" 2" 9'-2" 2" 2'-8" 2" 6'-0" 2" 2'-6" 2" 4'-4" 2" 2'-8" 2" 7'-6" 7'-6" 12'-6" 2" 2'-11" 2" 3'-0"2" 6'-0" 2" 12'-7" 5'-0" 5'-0" 5'-0" 5'-0" 5'-0" 5'-0" 5'-0" 5'-0" 5'-0" 5'-0" 5'-0" 5'-0" 5'-0" 5'-0" 5'-0" 5'-0" 5'-0" 5'-0" 5'-0" 5'-0" 5'-0" 2'-8" 2" 6'-0" 2" 2'-8" 2" 12'-0" 2" 2" 6'-10" 2" 2'-8" 2" 10'-0" 2" 6'-0" 2" 6'-0"2" 6'-0" 2" 11'-0" 18'-8" 2" 2'-11" 2" 2'-11" 2" 2'-11" 2" 2'-11" 2" 2'-11" 2" 2'-11" 2" 18'-8" EXISTING HEADER HEIGHT 2" 2'-11" 2" 2'-11" 2" 2'-11" 2" 2'-11" 2" 2'-11" 2" 2'-11" 2" 18'-8" EXISTING R.O. 2" 2'-11" 2" 2'-11" 2" 2'-11" 2" 2'-11" 2" 12'-6" 24'-10" 10'-0" EXISTING R.O. 11'-2" 2" 2'-11" 2" 2'-11" 2" 2'-11" 2" 2'-11" 2" 2'-11" 2" 2'-11" 2" 2'-11" 2" 2'-11" 2" 6'-0" 8'-0" 3'-0" 11'-0" 8'-0" 2" 3'-0" 2" 5'-7" 2" 5'-7" 2" 3'-0" 2" 2" 2'-4" 2" 5'-4" 2" 2'-10" 2" 11'-2" 8'-0" DOOR & FRAME ELEVATION KEYS TYPE 1 TYPE 2 TYPE 3 TYPE 4 TYPE 6TYPE 5 WINDOW & FRAME ELEVATION KEYS MARK "A" MARK "B" MARK "K" TYPE 7 TYPE 9 FLUSH TYPE 8 TYPE 10 TYPE 12 TYPE 13 TEMP GLASS TEMP GLASS TEMP GLASS TEMP GLASS TEMP GLASS TEMP GLASS TEMP GLASS TEMP GLASS TEMP GLASS TEMP GLASS TEMP GLASS TEMP GLASS TEMP GLASS TEMP GLASS TEMP GLASS TEMP GLASS TEMP GLASS TEMP GLASS TEMP GLASS TEMP GLASS TEMP GLASS TEMP GLASS TEMP GLASS TEMP GLASS TEMP GLASS TEMP GLASS TEMP GLASS TEMP GLASS MARK "C" MARK "D" MARK "E" MARK "F" MARK "G"OUTSIDE OUTSIDE MARK "H" OUTSIDE MARK "I" OUTSIDE MARK "J" 13 23 TEMP GLASS TEMP GLASS TEMP GLASS TEMP GLASS TEMP GLASS TEMP GLASS TEMP GLASS TEMP GLASS TEMP GLASS TEMP GLASS TEMP GLASS TEMP GLASS SPANDRAL GLASS TEMP GLASS TEMP GLASS TEMP GLASS TEMP GLASS TEMP GLASS TEMP GLASS TEMP GLASS TEMP GLASS TEMP GLASS TEMP GLASS TEMP GLASS TYPE 11 MARK "L" MARK "M" MARK "N" TEMP GLASS TEMP GLASS TEMP GLASS TEMP GLASS TEMP GLASS TEMP GLASS A.1.3 Page 19 of 68 A R CH ITECT S A R CH ITECT S parkerdesigngrouparchitects 843 785 5171 POST OFFICE BOX 5010 HILTON HEAD ISLAND SC 29938 A RENOVATION FOR : REVISIONS DATE OF ISSUE: TP SHEET OF SHEETS TP SCALE DRAWN BY CHECKED BY JOB NO. 2/25/26 HILTON HEAD , S.C. SERG GROUP THE ATRIUM BUILDING These documents & designs are the property of Parker Design Group | Architects & are not to be used or reproduced there of or for designs, working drawings, or construction of buildingswithout the written authorization from the copy write owner PDG|Architects 2024 copyright C ACCOUSTICAL CEILING @ 10'-0" AFF ACCOUSTICAL CEILING @ 8'-0" AFF ACCOUSTICAL CEILING @ 9'-0" AFF ACCOUSTICAL CEILING @ 9'-0" AFF ACCOUSTICAL CEILING @ 8'-0" AFF SHEETROCK CEILINGS @ 11'-0" AFF PAINTED EXPOSED CEILINGS WITH ARMSTRONG SOUNDSCAPESS 10" HIGH BLADES EXISTING ACCOUSTICAL CEILING PANELS PAINTED EXPOSED CEILINGS WITH ARMSTRONG SOUNDSCAPESS 10" HIGH BLADES A A A A A A A A A A A A A A A A B B BLINKER WALL RECESSED Project : Type: SPECIFICATION SHEET Page: 1 of 5 Due to continuous improvements, the information herein may be changed without notice 9320 Boul. St-Laurent, suite 100, Montréal (Québec) Canada H2N 1N7, P.: 514.523.1339 F.: 514.525.6107 www.sistemalux.com DM - R3 Last update: February 17, 2026 Luminaire characteristics: Power input: 3W to 34.5W Lumens: 18lm to 755lm (for 3000K, 90CRI) Luminaire efficacy: Up to 26lm/W Source: LED module 2700K : 90CRI, 3000K : 90CRI, 4000K : 80CRI. Lumen maintenance: 80% of initial lumens at 70 000 hours (L80 B10) Ta 77°F (25°C) 80% of initial lumens at 50 000 hours (L80 B10) Ta 104°F (40°C) (LM-80). Optics: Accent light. Material: Body: Die-cast aluminum Reflector: 99.98% pure anodized aluminum. Diffuser: 4mm thick acid etched tempered glass. Hardware: Stainless steel screws and silicone gaskets. Mounting: Recessed wall installation using madatory recessed box (to be ordered separately). Electrical: Integral high efficiency LED driver, rated at 50 000 hours, 120-277V. Dimming: 0-10V dimming (120-277V) down to 1%. Finish: Black (09) or aluminum gray (14) painted finish, following a double powder paint in 3 step process: surface treatment containing ceramic nano particles (Bonderite). Epoxy primer paint. Polyester powder paint with high resistance against UV rays and harsh weather conditions. See page 1 for other premium finishes available: white (01), green (07), burnished bronze (20) and anthracite gray (24). Resistance test protection Marine applications : 1200h. We provide RAL numbers that are similar, but we cannot guarantee an exact color match. For a more accurate color and gloss match, please contact customer service for a sample chip. Similar RAL numbers: Black RAL9005, aluminum gray RAL9006, white RAL9016, green RAL6028, burnished bronze RAL8019 and anthracite gray RAL9007. Weight: Microblinker: 1.79lb (0.81kg) Miniblinker: 4,76lb (2.16kg) Blinker: 7.62lb (3.46kg) Megablinker: 7.72lb (3.5kg) Warranty: 5 year limited warranty. Ratings: IP65, IK06 Certification: cULus listed for wet location. Collection of wall recessed luminaires for exterior applications. Designed for low mounting heights with downward asymmetric light distribution. Low luminance with the light source regressed inside the luminaire and shielded from all viewing angles. Exceptional European build quality with high corrosion resistant finish. Robust marine grade die-cast aluminum construction with stainless steel fasteners and factory sealed micro-prismatic glass diffuser. Standard finish 24 Premium finishes 01 07 14 14 2009 BLINKER WALL RECESSED Project : Type: SPECIFICATION SHEET Page: 2 of 5 Due to continuous improvements, the information herein may be changed without notice 9320 Boul. St-Laurent, suite 100, Montréal (Québec) Canada H2N 1N7, P.: 514.523.1339 F.: 514.525.6107 www.sistemalux.com DM - R3 Last update: February 17, 2026 scale 1:8 MOUNTING ACCESSORIES (TO BE ORDERED SEPARATELY) S6063 - Back box for Microblinker (S6060) 2¾" x 11¾" x 4⅛" (70mm x 300mm x 105mm) S6073 - Back box for Miniblinker (S6070) 4¼" x 11¾" x 5⅛" (110mm x 300mm x 130mm) S6083 - Back box for Blinker (S6080) 7½" x 11¾" x 5⅛" (190mm x 300mm x 130mm) S6023 - Back box for Megablinker (S6020) 7¼" x 17" x 6⅝" (187mm x 433mm x 170mm) ORDERING INFO MODEL S6060H - 2700K, 90CRI Microblinker S6060W - 3000K, 90CRI S6070H - 2700K, 90CRI Miniblinker S6070W - 3000K, 90CRI S6080H - 2700K, 90CRI Blinker S6080W - 3000K, 90CRI S6020H - 2700K, 90CRI Megablinker S6020W - 3000K, 90CRI S6060N - 4000K, 80CRI S6070N - 4000K, 80CRI FINISH 07 - Green 20 - Burnish brown01 - White 14 - Aluminum gray 24 - Anthracite gray 09 - Black S6080N - 4000K, 80CRI S6020N - 4000K, 80CRI VOLTAGE UNV - 120-277V FIXTURE - UNV - - D10 RECESSED BOX DIMMING D10 - 0-10V Standard Premium RESET INFO BLINKER WALL RECESSED Project : Type: SPECIFICATION SHEET Page: 3 of 5 Due to continuous improvements, the information herein may be changed without notice 9320 Boul. St-Laurent, suite 100, Montréal (Québec) Canada H2N 1N7, P.: 514.523.1339 F.: 514.525.6107 www.sistemalux.com DM - R3 Last update: February 17, 2026 DIMENSIONS Microblinker S6060 Installation in concrete using back box: S6063 Miniblinker S6070 Installation in concrete using back box: S6073 Blinker S6080 Installation in concrete using back box: S6083 Megablinker S6020 Installation in concrete using back box: S6023 FRONT VIEW SECTION VIEW FRONT VIEW SECTION VIEW FRONT VIEW FRONT VIEW SECTION VIEW 1¾" (45mm) 4⅛" (105 mm) 4" (100 mm) 7⅛" (180mm) 6¼" (157mm) 6⅝" (170mm) 9" (230mm) 9" (230mm) 9" (230mm) 17" (433mm) 11¾" (300mm) 11¾" (300mm) 5⅛" (130mm) SECTION VIEW 11¾" (300mm) 5⅛" (130mm) 12¾" (323mm) scale 1:10 Project Catalog # Type Prepared by Notes Date PS51871423 page 1 October 31, 2023 10:49 AM Interactive Menu • Order Information page 2 • Product Specifications page 3 • Energy Data page 3 • Photometric Data page 4 • Product Warranty RA Baffle Adjustable Recessed Canless LED Downlight 4" and 5/6" Baffle Adjustable Recessed Canless LED Downlights mount directly to the ceiling and provide up to 35° of tilt and 360° of rotation Typical Applications Residential Top Product Features • Available in 4" and 6" LED trims mount directly to ceilings - no housing required • Adjustable gimbal tilts up to 35° and r otates 360° to aim light where it's needed • 6-Position Switch: 5 Color Field-SeleCC Table soft white to daylight (2700K, 3000K, 3500K, 4000K, 5000K) + Dim-to-W arm (3000K dims to 1800K) • Selectable Lumen Switch: Choose between 600/900 lumens • 5% phase cut LE/TE dimming (120V input) with compatible controls (r eference the RA Dimming Guide) Can be used to comply with Title 24 Part 6 LED Enclosed Light Source Requirements (JA8) Refer to ENERGY STAR® Certified Products List. Can be used to comply with California Title 24 High Efficacy requirements. Certified to California Appliance Efficiency Database under JA8. additional product diagrams dim-to-warm option included RA6-DM Dimensional and Mounting Details Ø 4.19" [106.4mm] CUTOUT DIAMETERØ 5.13" [130.2mm] 2.72" [69.2mm] 4.04" [102.5mm] WIRE LENGTH 35º .25" [6.4mm] 1.46" [37mm] REGRESSION Ø 7.25" [184mm] 4.04" [102.5mm] WIRE LENGTH 4.09" [103.8mm] 35º .20" [5.1mm] Ø 6.13" [155.6mm] CUTOUT DIAMETER 1.38" [35mm] REGRESSION RA4-DM RA6-DM RA4-DM Product Certification Product Features RA Canless Series PS51871423 page 3 October 31, 2023 10:49 AM Product Specifications Selectable System • Use the 6-position color selector switch to c hoose between: Dim-to-Warm (3000K dims to 1800K), 2700K, 3000K, 3500K, 4000K, and 5000K • Use the lumen select switch to c hoose the preferred brightness level Module – Trim • Module construction includes LED array , heat sink, reflector, lens, baffle and trim ring • Regressed baf fle • Heat sink designed to conduct heat away from the LED ar ray, keeping the junction temperatures below specified maximums, even when installed in insulated ceiling environments • Adjustable gimbal tilts up to 35º and rotates up to 360º LED Array • Mid power LED array pro vides a uniform source with high efficiency and no pixilation • 90 CRI minimum, R9 greater than 50 • Color accuracy at 4 SDCM in between Endpoints, provide color accuracy and uniformity . • Factory default color temperature (CCT) is set to sof t white (3000K) Optical Assembly • Regressed lens • Impact-resistant polycarbonate • Convex form and lamp-lik e appearance Driver • Integral 120V 60 Hz constant cur rent driver provides noise free operation • Inline electrical quick connect and E26 adapter (pro vided) provides mains connections • Continuous, flick er-free phase cut (leading- edge/trailing-edge - LE/TE) dimming from 100% to 5% output with compatible dimmers • *See the RA Dimming Guide for compatible dimmer s Retention • No housing or junction box required • The included remote junction box may be used in direct contact with insulation • Installer must cut template out of drywall and install into aper ture with the clips compressed • When released, the spring clips will rest on to the back side of the dryw all holding the fixture in place • Not for installation in recessed cans • For new construction applications, use HAL O Canless Mounting Frames prior to drywall installation Gasket • Closed cell gask ets achieve restrictive airflow requirements without additional caulking Compliance • UL Certified US and Canada Type IC suitable for direct contact with air permeable insulation • Damp location listed. Not recommended for use in direct contact with spray foam insulation, reference NEMA LSD57-20 13 • Airtight cer tified per ASTM-E283 • EMI/RFI emissions per FCC 47CFR Par t 15 consumer limits • Contains no mercury or lead and RoHS compliant • Photometric testing in accordance with IES LM-79-08 • Lumen maintenance projections in accordance with IES LM-80-08 and TM-21 -1 1 • Can be used for State of California T itle 24 high efficacy luminaire compliance. Complies with Title 24 J A8-2022-E. • Can be used International Energy Conservation Code (IECC) high efficiency luminaire compliance. • ENERGY ST AR® listed, reference database for current listings Warranty • Five year limited warranty, consult website for details. www.cooperlighting.com/warranty Energy Data RA6LS9FSD2W1EWHDM - 3000K Catalog Number CCT Watts lumens LPW CRI RA6LS9FSD2W1EWHDM 600 Lumens 2700K 6.3 650 103.2 93 3000K 6.3 630 100.0 93 3500K 6.3 670 106.3 93 4000K 6.3 675 107.1 93 5000K 6.3 675 107.1 93 Catalog Number CCT Watts lumens LPW CRI RA6LS9FSD2W1EWHDM 900 Lumens 2700K 9.6 920 95.8 93 3000K 9.5 950 100.0 93 3500K 9.6 950 99.0 93 4000K 9.6 960 100.0 93 5000K 9.5 955 100.5 93 RA4LS9FSD2W1EWHDM - 3000K Catalog Number CCT Watts lumens LPW CRI RA4LS9FSD2W1EWHDM 600 Lumens 2700K 6.1 615 100.8 92 3000K 6.2 620 100.0 93 3500K 6.1 635 104.1 93 4000K 6.1 630 103.3 93 5000K 6.1 630 103.3 93 Catalog Number CCT Watts lumens LPW CRI RA4LS9FSD2W1EWHDM 900 Lumens 2700K 9.2 885 96.2 92 3000K 9.2 920 100.0 93 3500K 9.4 910 96.8 93 4000K 9.3 905 97.3 93 5000K 9.3 900 96.8 93 Lumens 600/900 Input Voltage 120V Input current 0.08A/0.05A Input Power 9.3W/6.1W Efficiency 76.64%/77.33% Inrush(A) 1.94 THD 16/12.2 PF 0.949/0.975 Sound Rating <=22dba Lumens 600/1000 Input Voltage 120V Input current 0.053A/0.079A Input Power 6.13W/9.32W Efficiency 76.64%/77.33% Inrush(A) 1.94 THD 16/12.2 PF 0.949/0.975 Sound Rating <=22dba PS51871423 page 4 October 31, 2023 10:49 AM RA Baffle Adjustable Recessed Canless LED Downlight Cooper Lighting Solutions 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.cooperlighting.com © 2023 Cooper Lighting Solutions All Rights Reserved. Specifications and dimensions sub- ject to change without notice. Photometric Data 22CZ2-24-UNVL830-CD1-U Electronic Driver Linear LED 5000K Spacing criterion: (II) 1.23 x mounting height, (⊥) 1.23 x mounting height Lumens: 11493 Input Watts: 87.7W Efficacy: 131.1 LPW Test Report: 22CZ2-24-UNVL830- CD1-U.IES 22CZ2-24-UNVL830-CD1-U Electronic Driver Linear LED 5000K Spacing criterion: (II) 1.23 x mounting height, (⊥) 1.23 x mounting height Lumens: 11493 Input Watts: 87.7W Efficacy: 131.1 LPW Test Report: 22CZ2-24-UNVL830- CD1-U.IES 0-deg 45-deg 90-deg 180° 170°160° 150° 140° 130° 120° 110° 100° 90° 80° 70° 60° 50° 40° 30°20°10°0° 489 367 245 122 0 0-deg 45-deg 90-deg 180° 170°160° 150° 140° 130° 120° 110° 100° 90° 80° 70° 60° 50° 40° 30°20°10°0° 460 345 230 115 0 RA4LS9FSD2W1EWHDM-900lm- 3000K Spacing criterion: (0-180) 1.09 | (90-270) 1.09 | (Diagonal) 1.14 Beam Angle: 81° Field Angle: 141° Lumens: 920 Input Watts: 9.2 W Efficacy: 100 LPW UGR: 20 Test Report: P710078 RA6LS9FSD2W1EWHDM-900lm- 3000K Spacing criterion: (0-180) 1.12 | (90-270) 1.12 | (Diagonal) 1.19 Beam Angle: 86° Field Angle: 147° Lumens: 950 Input Watts: 9.5 W Efficacy: 100 LPW UGR: 19 Test Report: P710098 Zonal Lumen Lumens % Lumens 0-30 351 38.2 0-40 537 58.3 0-60 807 87.7 0-90 920 100 Zonal Lumen Lumens % Lumens 0-30 336 35.3 0-40 522 55 0-60 816 85.9 0-90 950 100 TM-30-15 Rf = 91 Rg = 103 CRI/CIE Ra = 94.6 R9 = 74.6 TM-30-15 Rf = 93 Rg = 101 CRI/CIE Ra = 96.9 R9 = 81.3 81° 86° Project Catalog # Type Prepared by Notes Date PS514255325EN page 1 September 30, 2025 3:44 PM • Available in 12W, 18W, 26, & 38W (900 - 3,100 lumens) models • Av ailable in 5000K or 4000K (CCT) • Wall, inv erted or pole mount • Energy and maintenance sa vings up to 95% compared to HID • Energy efficient illumination r esults in up to 177LPW • Replaces 70W up to 450W HID equiv alents • Optional floodlighting kit conver ts from wall to floodlight, and pole mount Interactive Menu • Ordering Information page 2 • Product Specifications page 2 • Energy and Performance Data page 3 Dimensional Details Wall Mount Luminaire Lumark Crosstour Series Product Certifications & Features 12W, 18W, 26W 5-3/4" [146mm] 38W 6-5/8" [168mm] 12W, 18W, 26W 6-3/4" [171mm] 38W 8" [203mm] 12W, 18W, 26W 3-5/8" [92mm] 38W 4" [102mm] 8-3/4" [222mm] 6-1/4" [159mm] 11" [279mm] 17-1/2" [445mm] 10" [254mm] 10" [254mm] 17-1/2" [445mm] 19-1/4" [489mm] 19-1/4" [489mm] Crosstour Full Cut-off Crosstour MAXX Full Cut-off Crosstour Escutcheon Plates Crosstour MAXX Escutcheon Plate Quick Facts © 2016 Axis Lighting Inc. 1.800.263.2947 [T] 5 14.948.6272 Product design and development is an ongoing process at Axis Lighting.We reserve the right to change specifications. Contact Axis for the latest product information. 1 / 6 FILE NAME:EX2S.SPEC November 18, 2025 axislighting.com EX2S PRODUCT ID NOM. LUM/FT CRI COLOR TEMP . (choose one) SHIELDING EX2S Extend 2 Surface 300 300 lm/ft - min 80 80 CRI 27 2700 K SO spotless lens 750 750 lm/ft - max for 90 90 CRI 30 3000 K GZ Graze GZ, WW, ASO* 35 3500 K WW Wallwash 1000 1000 lm/ft - max 40 4000 K ASO Asymmetric 50 5000 K BW Batwing Outputs between listed min and max are available. * 750 lm/ft max. only for GZ, WW and ASO. Consult factory for outputs outside of the listed range. Choose only one of the options above; LENGTH (FT) FINISH VOLTAGE DRIVER CIRCUITS 2 2’ AP aluminum paint 120 120 V DP dimming (0-10V) 1% 1 1 circuit 3 3’ W white 277 277 V temp. range -22°F - +104°F (-30°C - +40°C) 2 2 circuits 4 4’ BLK black 347 347 V* DPX dimming (0-10V) 1%, extended +E(#) emergency circuit* 5 5’ C custom UNV universal temp. range -40°F - +122°F (-40°C - +50°C) +NL(#) night light circuit* 6 6’ LT(#) Lutron* +GTD(#) generator transfer 7 7’ BI bi-level dimming device* ** 8 8’ O(#) other* 12 12’ S(L) System Run Lengths are nominal. Exact lengths can be specified, please consult factory. *Remote surge protection device only Integral drivers standard, remote drivers available for environments outside of driver operating temperature range or where fixture access may be limited. See page 2 for more details. * Please consult factory; see page 2. *Specify quantity. Minimum 3ft fixture length. **120V and 277V only. Please specify. MOUNTING BATTERY (OPTIONAL) OTHER (OPTIONAL) CUSTOM (OPTIONAL) SB surface bracket B(#) battery pack (integral)* +EF end feed* C custom S surface ceiling* BR(#) battery pack (remote)** +N natatorium finish SBBP surface bracket with bird protection * Requires opening fixture for installation. *Minimum 3ft; **Dry/Damp location only. Please consult factory. * End Feed standard for S mounting Please specify Notes Type Project Ordering Guide Surface mountExtend 2 NOMINAL LUMEN OUTPUT INPUT WATTS* EFFICACY SHIELDING 1000 lm/ft 9.8 W/ft 101 lm/W SO 750 lm/ft 7.2 W/ft 103 lm/W GZ 750 lm/ft 7.4 W/ft 101 lm/W ASO 1000 lm/ft 9.7 W/ft 102 lm/W BW 750 lm/ft 7.4 W/ft 101 lm/W WW *Please consult factory for custom lumen output and wattage. PERFORMANCE PER LINEAR FOOT AT 3500K, 80 CRI SHIELDING DIRECT Spotless Lens SO Wall Wash WW Graze GZ Asymmetric ASO Batwing BW 2 13/16" 2 1/2" 3/4" Lumark Crosstour Series PS514255325EN page 2 September 30, 2025 3:44 PM Crosstour Stock Ordering Information Ordering Information SAMPLE NUMBER: XTOR2B-W-WT-PC1 Domestic Preferences Series 1 LED Kelvin Color Housing Color Options (Add as Suffix) Accessories (Order Separately) [Blank]=Standard BAA=Buy American Act 7 TAA=Trade Agreements Act 7 BABA=Build America Buy America Act 8 XTOR1B=Small Door, 12W XTOR2B=Small Door, 18W XTOR3B=Small Door, 26W XTOR4B=Medium Door, 38W [Blank]=Bright White (Standard), 5000K W=Neutral White, 4000K Y=Warm White, 3000K [Blank]=Carbon Bronze (Standard) WT=Summit White BK=Black BZ=Bronze AP=Grey GM=Graphite Metallic DP=Dark Platinum PC1=Photocontrol 120V 2 PC2=Photocontrol 208-277V 2, 3 347V=347V 4 HA=50ºC High Ambient 4 XTORFLD-KNC=Knuckle Floodlight Kit 6 XTORFLD-TRN=Trunnion Floodlight Kit 6 XTORFLD-KNC-WT=Knuckle Floodlight Kit, Summit White 6 XTORFLD-TRN-WT=Trunnion Floodlight Kit, Summit White 6 EWP/XTOR=Escutcheon Wall Plate, Carbon Bronze EWP/XTOR-WT=Escutcheon Wall Plate, Summit White Full Cutoff XTOR6B=MAXX, 58W XTOR8B=MAXX, 81W XTOR12B=MAXX, 102W Refractive Lens XTOR6BRL=MAXX, 58W XTOR8BRL=MAXX, 81W XTOR12BRL=MAXX, 102W 347V=347V 9, 10, 11, 12 480V=480V 9, 10, 11, 12, 13 PC1=Photocontrol 120V 7 PC2=Photocontrol 208-277V 14, 15 PMA=Pole Mount Arm (C Drilling) with Round Adapter 10, 16 MS-L20=Motion Sensor for ON/OFF Operation 9, 10, 17, 18 MS/DIM-L20=Motion Sensor for Dimming Operation 9, 10, 17, 18, 19, 20, 21 CBP=Cold Weather Battery Pack 9, 10, 22, 23, 24 HA=50ºC High Ambient 24 WG-XTORMX=Crosstour MAXX Wire Guard PB120V=Field Installed 120V Photocontrol PB277V BUTTON PC=Field Installed 208-277V Photocontrol 15 VA1040-XX=Single Tenon Adapter for 3-1/2” O.D. Tenon 25 VA1041-XX=2@180° Tenon Adapter for 3-1/2” O.D. Tenon 25 VA1042-XX=3@120° Tenon Adapter for 3-1/2” O.D. Tenon 25 VA1043-XX=4@90° Tenon Adapter for 3-1/2” O.D. Tenon 25 VA1044-XX=2@90° Tenon Adapter for 3-1/2” O.D. Tenon 25 VA1045-XX=3@90° Tenon Adapter for 3-1/2” O.D. Tenon 25 VA1046-XX=2@120° Tenon Adapter for 3-1/2” O.D. Tenon 25 VA1033-XX=Single Tenon Adapter for 2-3/8” O.D. Tenon 25 VA1034-XX=2@180° Tenon Adapter for 2-3/8” O.D. Tenon 25 VA1035-XX=3@120° Tenon Adapter for 2-3/8” O.D. Tenon 25 VA1036-XX=4@90° Tenon Adapter for 2-3/8” O.D. Tenon 25 VA1037-XX=2@90° Tenon Adapter for 2-3/8” O.D. Tenon 25 VA1038-XX=3@90° Tenon Adapter for 2-3/8” O.D. Tenon 25 VA1039-XX=2@120° Tenon Adapter for 2-3/8” O.D. Tenon 25 EWP/XTORMX=Escutcheon Wall Plate, Carbon Bronze EWP/XTORMX-WT=Escutcheon Wall Plate, Summit White FSIR-100=Wireless Configuration Tool for Occupancy Sensor 14 NOTES: 1. De signLights Consortium® Qualified and classified for both DLC Standard and DLC Premium, refer to designlights.org for details. 2. Ph otocontrols are factory installed. 3. Or der PC2 for 347V models. 4. Th ru-branch wiring not available with HA option or with 347V. XTOR3B not available with HA and 347V or 120V combination. 5. Wi re guard for wall/surface mount. Not for use with floodlight kit accessory. 6. Fl oodlight kit accessory supplied with knuckle (KNC) or trunnion (TRN) base, small and large top visors and small and large impact shields. 7. On ly product configurations with these designated prefixes are built to be compliant with the Buy American Act of 1933 (BAA) or Trade Agreements Act of 1979 (TAA), respectively. Please refer to DOMESTIC PREFERENCES website for more information. Components shipped separately may be seperately analyzed under domestic preference requirements. 8. On ly product configurations with these prefixes are built to be compliant with the Buy American Act of 1933 (BAA) or the Build America Buy America Act (BABA). BABA is the minimum Government compliance requirement for the Build America Buy America standards which is part of the Infrastructure and Investment Jobs Act (IIJA). Individual Government Agencies may have more stringent compliance standards. Please refer to the DOMESTIC PREFERENCES website or consult the CLS Domestic Preferences team for more information. Components shipped separately may be separately analyzed under domestic preference requirements. 9. No t available with HA option. 10. De ep back box is standard for 347V, 480V, CBP, PMA, MS-L20 and MS/DIM-L20. 11. No t available with CBP option. 12. Th ru-branch wiring not available with HA option or with 347V. 13. On ly for use with 480V Wye systems. Per NEC, not for use with ungrounded systems, impedance grounded systems or corner grounded systems (commonly known as Three Phase Three Wire Delta, Three Phase High Leg Delta and Three Phase Corner Grounded Delta systems). 14. No t available with MS-L20 and MS/DIM-L20 options. 15. Us e PC2 with 347V or 480V option for photocontrol. Factory wired to 208-277V lead. 16. Cu stomer is responsible for engineering analysis to confirm pole and fixture compatibility for all applications. Refer to our white paper WP513001EN for additional support information. 17. Fo r use in downlight orientation only. Optimal coverage at mounting heights of 9’-20’. 18. 12 0V thru 277V only. 19. Fa ctory set to 50% power reduction after 15-minutes of inactivity. Dimming driver included. 20 . In cludes integral photo sensor. 21. Th e FSIR-100 configuration tool is required to adjust parameters including high and low modes, sensitivity, time delay, cutoff, and more. Consult your lighting representative at Eaton for more information. 22. 12 0V or 277V operation only. 23. Op erating temperatures -20°C to 25°C. 24. No t available in XTOR12B or XTOR12BRL models. 25. Re place XX with housing color. 12W Series 18W Series 26W Series 38W Series XTOR1B=12W, 5000K, Carbon Bronze XTOR2B=18W, 5000K, Carbon Bronze XTOR3B=26W, 5000K, Carbon Bronze XTOR4B=38W, 5000K, Carbon Bronze XTOR1B-WT=12W, 5000K, Summit White XTOR2B-W=18W, 4000K, Carbon Bronze XTOR3B-W=26W, 4000K, Carbon Bronze XTOR4B-W=38W, 4000K, Carbon Bronze XTOR1B-PC1=12W, 5000K, 120V PC, Carbon Bronze XTOR2B-WT=18W, 5000K, Summit White XTOR3B-WT=26W, 5000K, Summit White XTOR4B-WT=38W, 5000K, Summit White XTOR1B-W=12W, 4000K, Carbon Bronze XTOR2B-PC1= 18W, 5000K, 120V PC, Carbon Br onze XTOR3B-PC1= 26W, 5000K, 120V PC, Carbon Br onze XTOR4B-PC1= 38W, 5000K, 120V PC, Carbon Br onze XTOR2B-W-PC1= 18W, 4000K, 120V PC, Carbon Br onze XTOR3B-W-PC1=26W, 4000K, 120V PC, Carbon Bronze XTOR4B-W-PC1= 38W, 4000K, 120V PC, Carbon Bronze XTOR2B-347V= 18W, 5000K, Carbon Br onze, 347V XTOR3B-347V=26W, 5000K, Carbon Bronze, 347V XTOR4B-347V=38W, 5000K, Carbon Bronze, 347V XTOR2B-WT -PC1=18W, 5000K, 120V PC, Summit White XTOR3B-PC2=26W, 5000K, 208-277V PC, Carbon Bronze © 2016 Axis Lighting Inc. 1.800.263.2947 [T] 5 14.948.6272 Product design and development is an ongoing process at Axis Lighting.We reserve the right to change specifications. Contact Axis for the latest product information. 2 / 6 FILE NAME:EX2S.SPEC November 18, 2025 axislighting.com Surface mountExtend 2 CONSTRUCTION Housing Extruded aluminum (0.08'' nominal) Up to 70% recycled content End Cap Cast aluminum Interior Brackets Die formed sheet steel (18 gauge) Gaskets Silicone rubber Lens Gaskets Extruded elastomer Lens Extruded acrylic Fasteners All external fasteners are tamper proof TORX T20 OPTICS SO Spotless lens; ASO Asymmetric Spotless lens; WW Wallwash; BW Batwing; GZ Graze. WEIGHT 4 ft 7 lbs / 3.2 kg 8 ft 14 lbs / 6.4 kg 12 ft 21 lbs / 9.6 kg FINISH Powder coated, custom finishes are available. EXTEND 2 is also available with pendant, wall and recessed mount options. Specification sheets and installation sheets for all mountings for EXTEND 2 luminaires are available for download at www.axislighting.com OTHER MOUNTING OPTIONS Impact modified PMMA lens used for all shielding options. Lengths of 2'-12' standalone are available. Runs of EXTEND2 that are greater than 12’ in length are designated as systems (S(L)). System runs are comprised of a combination of 4’ to 8’ sections to be assembled on site using our joining system which includes a 1” sealed joiner plate. For more information on systems and joining, please refer to the EXTEND2 installation sheets available for download at www.axislighting.com. SYSTEM (S(L)) 1" Limited 5-year warranty is available. Warranty is valid provided luminaires are installed and used according to specifications. For full terms and conditions, please consult warranty section at axislighting.com. WARRANTY APPROVALS Certified wet locations to UL and CUL standards. IP66 and IK10 rated. ELECTRICAL DP DPX 0-10V dimming driver. Ambient operating temperature -22°F - 104°F (-30°C - +40°C) 0-10V dimming driver with extended temperature range -40°F - 122°F (-40°C - +50°C) Lutron driver** LDE1 - Hi-lume 1% EcoSystem with Soft-on, Fade-to- Black (min ambient operating temperature - 32°F (0°C). Other drivers** DALI* - Digital Addressable Lighting Interface DMX* - Digital Multiplex Xitanium SR* - For wireless sensor Emergency B(#) Integral Emergency Battery pack, 3ft minimum. Ambient operating temperature -4°F - 122°F(-20° to 50°C) for 120V to 277V; 32°F - 122°F (0°C to 50°C) for 347V BR(#) Remote emergency battery pack operating temperature range -4°F - 122°F (-20°C- +50°C) for 120V to 277V; 32°F - 122°F (0°C - +50°C) for 347V. Input Voltage 120V, 277V, 347V, UNV. Surge Protection Extend comes standard with surge protection device. Incorporating these components may have limitations or affect the length of the luminaire. Please contact factory for more details. * Ambient operating range: -4°F - 104°F (-20°C - +40°C) **Remote only with EX2PDI. LED SYSTEM CRI Minimum 80 or 90 color rendering index. CCT Single Color Choice of 2700K, 3000K, 3500K, 4000K and 5000K color temperature with a great color consistency (within 3–step MacAdam ellipse). Both within fixture and fixture to fixture. LED life Minimum 50,000h with 85% of lumen maintenance in 25 0C ambient temperature, in compliance with IES LM-80 testing measurements. Thermal Management Aluminum housing acting as the heat sink to maximize life. Environment Dry and wet location rated IP66 for outdoor or indoor use. Impact resistant rated IK10. For extreme temperature environments, please contact factory. Remote drivers available for environments outside of driver operating temperature range or where fixture access may be limited. Ambient operating temperature range for fixtures with remote drivers -40°F to +167°F (-40°C - +75°C). © 2016 Axis Lighting Inc. 1.800.263.2947 [T] 5 14.948.6272 Product design and development is an ongoing process at Axis Lighting.We reserve the right to change specifications. Contact Axis for the latest product information. 5 / 6 FILE NAME:EX2S.SPEC November 18, 2025 axislighting.com All IES files for other lamping are available for download at: www.axislighting.com LUMINANCE DATA (cd/m 2) Horizontal Angles Vertical Angle 0 45 90 45 10630 9359 11321 55 8858 8728 11689 65 7462 7806 11399 75 6114 6524 8813 85 3919 4146 3429 Lumen/ft: 750 lm/ft Total Lumens: 2987 lm (for 4ft) Input Watts: 29.6 W Efficacy: 101 lm/W IES FILE: EX2S-750-80-35-WW-4.IES TESTED ACCORDING TO IES LM-79-2019 750 lm/ft Horizontal Angles Vertical Angle 0 22.5 45 67.5 90 0 1232 1232 1232 1232 1232 5 1222 1149 1097 1057 1052 15 1134 948 852 807 797 25 965 752 693 686 690 35 751 584 578 611 634 45 535 440 471 535 570 55 362 313 356 437 477 65 224 203 235 312 343 75 113 103 120 156 162 85 24 23 26 22 21 90 3 4 4 3 3 CANDELA DISTRIBUTION ZONAL LUMENS Lumens Zone 0 0-10 117 10-20 342 20-30 541 30-40 610 40-50 527 50-60 404 60-70 274 70-80 139 80-90 33 90 PHOTOMETRIC CURVE 90º 60º 30º0º ° 30°0° 90° 0 ° 1994 1496 997 499 WW Walwash LUMINANCE DATA (cd/m 2) Horizontal Angles Vertical Angle 0 45 90 45 10630 9359 11321 55 8858 8728 11689 65 7462 7806 11399 75 6114 6524 8813 85 3919 4146 3429 Lumen/ft: 750 lm/ft Total Lumens: 2987 lm (for 4ft) Input Watts: 29.6 W Efficacy: 101 lm/W IES FILE: EX2S-750-80-35-ASO-4.IES TESTED ACCORDING TO IES LM-79-2019 750 lm/ft Horizontal Angles Vertical Angle 0 22.5 45 67.5 90 0 1232 1232 1232 1232 1232 5 1222 1149 1097 1057 1052 15 1134 948 852 807 797 25 965 752 693 686 690 35 751 584 578 611 634 45 535 440 471 535 570 55 362 313 356 437 477 65 224 203 235 312 343 75 113 103 120 156 162 85 24 23 26 22 21 90 3 4 4 3 3 CANDELA DISTRIBUTION ZONAL LUMENS Lumens Zone 0 0-10 117 10-20 342 20-30 541 30-40 610 40-50 527 50-60 404 60-70 274 70-80 139 80-90 33 90 PHOTOMETRIC CURVE 90º 60º 30º0º ° 30°0° 90° 0 ° 1994 1496 997 499 ASO Asymmetric PHOTOMETRIC DATA Surface mountExtend 2 Lumark Crosstour Series PS514255325EN page 4 September 30, 2025 3:44 PM Crosstour MAXX Power and Lumens LED Information XTOR6B XTOR6BRL XTOR6B-W XTOR6BRL-W XTOR6B-Y XTOR6BRL-Y Delivered Lumens 6,129 6,225 6,038 6,133 5,611 5,826 B.U.G. Rating B1-U0-G1 B2-U4-G3 B1-U0-G1 B2-U4-G3 B1-U0-G1 B2-U4-G3 CCT (Kelvin) 5000K 5000K 4000K 4000K 3000K 3000K CRI (Color Rendering Index) 70 70 70 70 70 70 Power Consumption (Watts) 58W 58W 58W 58W 58W 58W LED Information XTOR8B XTOR8BRL XTOR8B-W XTOR8BRL-W XTOR8B-Y XTOR8BRL-Y Delivered Lumens 8,502 8,635 8,373 8,504 7,748 8,079 B.U.G. Rating B2-U0-G1 B2-U4-G3 B2-U0-G1 B2-U4-G3 B2-U0-G1 B2-U4-G3 CCT (Kelvin) 5000K 5000K 4000K 4000K 3000K 3000K CRI (Color Rendering Index) 70 70 70 70 70 70 Power Consumption (Watts) 81W 81W 81W 81W 81W 81W LED Information XTOR12B XTOR12BRL XTOR12B-W XTOR12BRL-W XTOR12B-Y XTOR12BRL-Y Delivered Lumens 12,728 13,458 12,539 13,258 11,861 12,595 B.U.G. Rating B2-U0-G1 B2-U4-G3 B2-U0-G1 B2-U4-G3 B2-U0-G1 B2-U4-G3 CCT (Kelvin) 5000K 5000K 4000K 4000K 3000K 3000K CRI (Color Rendering Index) 70 70 70 70 70 70 Power Consumption (Watts) 102W 102W 102W 102W 102W 102W Energy and Performance Data Crosstour Power and Lumens LED Information XTOR1B XTOR1B-W XTOR1B-Y XTOR2B XTOR2B-W XTOR2B-Y XTOR3B XTOR3B-W XTOR3B-Y XTOR4B XTOR4B-W XTOR4B-Y Delivered Lumens (Wall Mount) 1,418 1,396 1,327 2,135 2,103 1,997 2,751 2,710 2,575 4,269 4,205 3,995 Delivered Lumens (With Flood Accessory Kit) 1 1,005 990 940 1,495 1,472 1,399 2,099 2,068 1,965 3,168 3,121 2,965 B.U.G. Rating 2 B1-U0-G0 B1-U0-G0 B1-U0-G0 B1-U0-G0 B1-U0-G0 B1-U0-G0 B1-U0-G0 B1-U0-G0 B1-U0-G0 B2-U0-G0 B2-U0-G0 B2-U0-G0 CCT (Kelvin) 5,000 4,000 3,000 5,000 4,000 3,000 5,000 4,000 3,000 5,000 4,000 3,000 CRI (Color Rendering Index) 70 70 70 70 70 70 70 70 70 70 70 70 Power Consumption (Watts) 12W 12W 12W 18W 18W 18W 26W 26W 26W 38W 38W 38W NOTES: 1 Includes shield and visor. 2 B.U.G. Rating does not apply to floodlighting. A.1.4FIRST FLOOR REFLECTED CEILING PLAN SCALE: 1/8" = 1'-0" 1 A.1.4 FIXTURE "A" FIXTURE "B" FIXTURE "C" FIXTURE "D" 7 i i i i LZEC7EC"TE- <LIE7773LITE I Product Features product Certification 4 and 5/6 Baffle Adjustable Recessed Canless LED Downlights mount directly to the ceiling and provide up to 35 of tilt and 360 of rotation Tie.al iplie.atis HALO RA Baffle Adjustable Recessed Canless LED Downlight p Interactive Menu Order information eaProduct Specifications aa Energy Data aphotometric Data eaProduct Warranty goLo·-­ttitO COOPERhiioktiesO COOPERhiiokties EE 5E Psst8.714.23 page1 • Adjustable gimbal tilts up to 35" and rotates 30 to aim light where it's needed 6position Switch. 5 Color Field-SeleccTable soft white to daylight (2700K. 3000K, 3500K, 4000K, 5000K) + Dim-to-Warm (3000K dims to 1800K) Selectable Lumen Switch. Choose between 600/900 umens • 5%phase cut LETE dimming (120y input) with compatible controls (reference the RA Dimming Guide) -, r-.. r-.. .'-' '-' ..._,,Dimensional and Mounting Details Top Product Features • Available in 4 and6 LED trims mount directly to ceilings - no housing required O COOPERhiiokties n 1 -0- -<D­I l I d. 1 I I -<p- - -I 1I I I -o-1 ±[] NI I I I I I I I I I l I "- I J I I = I I I I I I I I t [l_] H LI LI II I H - -} H CI: CI: 11 Ir rj1 1Lt.,I I l~ ..I 1_11_1_ - - - 1»=HJ ± l ElH =ji /H Hr lHH ] t l •t» IEl IH Hl El HH -\ I MINIM MM /~ -t )L II II JI, II II #. • El El El El H H H sEcTON Ew scTON WEw FRONT EW H,ptmo) rRoNT Vw Megablinker $60.20 itneerttietote. hi Meniblinker S6070 itneerttietote. hi./3 t• hhtutbot. hi.rt, e•toat.} est.h3.1pp4hi03,pig woo• I Surface mount scTON WEw '.'to5 mom) EcTo w I ##2%% 921# FRONT EW rRoNT yEw Blinker S6080 itcotetie, tote. hi.3 DIMENSIONS Miroblinker s6060 BLINKER I" Extend 2 SISTEMALUX (e RESET INFO [ Psst 4.298900 petpeer o. 20.$dpo eriurm [or.ow []a-so[]o»-sos t•g hhtutbot. hi.rt, e•toa.} eth3.1pg# p4hi03,pig woo• Surface mount /e nag2,%geetrtsw-gee,/,"gooft rt DOMMNG 0to-oov VOLTAGE uwv.2o-27v • UNV • • D10 sen-gee"te0soao MODEL icoroblinker Minitblinker Binker Megablinker []so-zoo.ooco [sso7on.zoo.ooc []soon-zookooc []s6020-2oox.oocRo [soow-oooooco [so7ow-sooooocno [sosowoo.oocni] []s02ow-3ooo 9oco []so-«ooo.soc [so7ow.«ooosoc []soot-«ooosocs []s02oN-«oook. soc no.ggeg%pg-, fQ 111>nm,><nnm,100mm1 u 0 @ ) ORDERING INFO BLINKER iro.poit,pyat. no.oqt ,pp. io.prop¢.lo aloroes.7to.ii iLeo lee. to.4/totteee.iy io.7yo.pi ,Ltlee.i/ non.pitatee iro.•tattee. ire2,toe. irotitornroopti• iro.itrtatto yr.ittot,ateto yo.ittattea rip itpy pc at irorig,ht• irogrog•it iroroahttee Crosstour pteek Ordering hfermattion .r .7 r JrI J il optitth l g it.itetr•• ali pt lo #•zed.hi flhrihetttritd,it it .r../ih kl. tilho•hohohithtt•lo itl trhttoehttis littt#EgeEEEEL Ege=EE2EE=EE=EE=I.EEEE==.tlietr tr. Ordering Information I" MOUNTING ACCESSORIES topart.. FINISH Standard Tot-woe [024.+note go [«o»] I /e Extend 2 SISTEMALUX lo ~--M -• ri# b9wt t0ti lo i# 12wt 103iw /ft 7tit 10tie/ i# h97wt to2iw By /ft 7tit 10tie/ pon.ult hctony or ustor ireoutput and watt.ae. PERFORMANCE PER LUNEAR F0OT Ar 3500K.so cRI Project Type Notes 9es&@pg I □□■ ■■■ Surface mount II Extend 2 SISTEMALUX Ordering Guide H\ i HI I O o ·0- 0 I 11 11 11 11 I O I H LG4 ... I H +-l i lI I I ~ I O o O O I I I #% 11 11 11 . 0 (e /e [e [e puv dint0-0) 1% temp. nae-22f-»tat.or-oatopining•ptended « emergency circuit temp. aea¥-t22far-oioro +tunny night hight oroar tot «rps. generator trashier eldoing detee. To.toeone) #±to too0 in,/t- ma titetoitLt6tr2 } » } 4 s « 1 ET} item hare ii• •tri. oe2hr.hiiiile ti.2i.eyeid 0ass77r1rt $14.9as.8272 0 ass77r1rt $14.9ass272 (e le0 le assaistinting.comI ~~to"~~~rt $14.9as.8272 uroroouu ororio»au ustoto»au3$ arhoe bnoctet a battery poteatr"Gag] on eaeo ·oooorot»edacebracioet with bind. protector --------· I ,,.hieet•iit• heretg Page 20 of 68 A R CH ITECT S A R CH ITECT S parkerdesigngrouparchitects 843 785 5171 POST OFFICE BOX 5010 HILTON HEAD ISLAND SC 29938 A RENOVATION FOR : REVISIONS DATE OF ISSUE: TP SHEET OF SHEETS TP SCALE DRAWN BY CHECKED BY JOB NO. 2/25/26 HILTON HEAD , S.C. SERG GROUP THE ATRIUM BUILDING These documents & designs are the property of Parker Design Group | Architects & are not to be used or reproduced there of or for designs, working drawings, or construction of buildingswithout the written authorization from the copy write owner PDG|Architects 2024 copyright C 6'-0" O.C. ACCOUSTICAL CEILING @ 9'-0" AFF PAINTED EXPOSED CEILINGS PAINTED EXPOSED CEILINGS SHEETROCK CEILINGS @ 9'-0" O.C. SHEETROCK CEILINGS @ 9'-0" O.C. WOOD CEILINGS ON FURRING STRIPS ON EXISTING PURLINS WOOD CEILINGS ON FURRING STRIPS ON EXISTING PURLINS PAINTED EXPOSED CEILINGS WITH ARMSTRONG SOUNDSCAPESS 10" HIGH BLADES B CCCCCCCC C C C D D B BLINKER WALL RECESSED Project : Type: SPECIFICATION SHEET Page: 1 of 5 Due to continuous improvements, the information herein may be changed without notice 9320 Boul. St-Laurent, suite 100, Montréal (Québec) Canada H2N 1N7, P.: 514.523.1339 F.: 514.525.6107 www.sistemalux.com DM - R3 Last update: February 17, 2026 Luminaire characteristics: Power input: 3W to 34.5W Lumens: 18lm to 755lm (for 3000K, 90CRI) Luminaire efficacy: Up to 26lm/W Source: LED module 2700K : 90CRI, 3000K : 90CRI, 4000K : 80CRI. Lumen maintenance: 80% of initial lumens at 70 000 hours (L80 B10) Ta 77°F (25°C) 80% of initial lumens at 50 000 hours (L80 B10) Ta 104°F (40°C) (LM-80). Optics: Accent light. Material: Body: Die-cast aluminum Reflector: 99.98% pure anodized aluminum. Diffuser: 4mm thick acid etched tempered glass. Hardware: Stainless steel screws and silicone gaskets. Mounting: Recessed wall installation using madatory recessed box (to be ordered separately). Electrical: Integral high efficiency LED driver, rated at 50 000 hours, 120-277V. Dimming: 0-10V dimming (120-277V) down to 1%. Finish: Black (09) or aluminum gray (14) painted finish, following a double powder paint in 3 step process: surface treatment containing ceramic nano particles (Bonderite). Epoxy primer paint. Polyester powder paint with high resistance against UV rays and harsh weather conditions. See page 1 for other premium finishes available: white (01), green (07), burnished bronze (20) and anthracite gray (24). Resistance test protection Marine applications : 1200h. We provide RAL numbers that are similar, but we cannot guarantee an exact color match. For a more accurate color and gloss match, please contact customer service for a sample chip. Similar RAL numbers: Black RAL9005, aluminum gray RAL9006, white RAL9016, green RAL6028, burnished bronze RAL8019 and anthracite gray RAL9007. Weight: Microblinker: 1.79lb (0.81kg) Miniblinker: 4,76lb (2.16kg) Blinker: 7.62lb (3.46kg) Megablinker: 7.72lb (3.5kg) Warranty: 5 year limited warranty. Ratings: IP65, IK06 Certification: cULus listed for wet location. Collection of wall recessed luminaires for exterior applications. Designed for low mounting heights with downward asymmetric light distribution. Low luminance with the light source regressed inside the luminaire and shielded from all viewing angles. Exceptional European build quality with high corrosion resistant finish. Robust marine grade die-cast aluminum construction with stainless steel fasteners and factory sealed micro-prismatic glass diffuser. Standard finish 24 Premium finishes 01 07 14 14 2009 BLINKER WALL RECESSED Project : Type: SPECIFICATION SHEET Page: 2 of 5 Due to continuous improvements, the information herein may be changed without notice 9320 Boul. St-Laurent, suite 100, Montréal (Québec) Canada H2N 1N7, P.: 514.523.1339 F.: 514.525.6107 www.sistemalux.com DM - R3 Last update: February 17, 2026 scale 1:8 MOUNTING ACCESSORIES (TO BE ORDERED SEPARATELY) S6063 - Back box for Microblinker (S6060) 2¾" x 11¾" x 4⅛" (70mm x 300mm x 105mm) S6073 - Back box for Miniblinker (S6070) 4¼" x 11¾" x 5⅛" (110mm x 300mm x 130mm) S6083 - Back box for Blinker (S6080) 7½" x 11¾" x 5⅛" (190mm x 300mm x 130mm) S6023 - Back box for Megablinker (S6020) 7¼" x 17" x 6⅝" (187mm x 433mm x 170mm) ORDERING INFO MODEL S6060H - 2700K, 90CRI Microblinker S6060W - 3000K, 90CRI S6070H - 2700K, 90CRI Miniblinker S6070W - 3000K, 90CRI S6080H - 2700K, 90CRI Blinker S6080W - 3000K, 90CRI S6020H - 2700K, 90CRI Megablinker S6020W - 3000K, 90CRI S6060N - 4000K, 80CRI S6070N - 4000K, 80CRI FINISH 07 - Green 20 - Burnish brown01 - White 14 - Aluminum gray 24 - Anthracite gray 09 - Black S6080N - 4000K, 80CRI S6020N - 4000K, 80CRI VOLTAGE UNV - 120-277V FIXTURE - UNV - - D10 RECESSED BOX DIMMING D10 - 0-10V Standard Premium RESET INFO BLINKER WALL RECESSED Project : Type: SPECIFICATION SHEET Page: 3 of 5 Due to continuous improvements, the information herein may be changed without notice 9320 Boul. St-Laurent, suite 100, Montréal (Québec) Canada H2N 1N7, P.: 514.523.1339 F.: 514.525.6107 www.sistemalux.com DM - R3 Last update: February 17, 2026 DIMENSIONS Microblinker S6060 Installation in concrete using back box: S6063 Miniblinker S6070 Installation in concrete using back box: S6073 Blinker S6080 Installation in concrete using back box: S6083 Megablinker S6020 Installation in concrete using back box: S6023 FRONT VIEW SECTION VIEW FRONT VIEW SECTION VIEW FRONT VIEW FRONT VIEW SECTION VIEW 1¾" (45mm) 4⅛" (105 mm) 4" (100 mm) 7⅛" (180mm) 6¼" (157mm) 6⅝" (170mm) 9" (230mm) 9" (230mm) 9" (230mm) 17" (433mm) 11¾" (300mm) 11¾" (300mm) 5⅛" (130mm) SECTION VIEW 11¾" (300mm) 5⅛" (130mm) 12¾" (323mm) scale 1:10 Project Catalog # Type Prepared by Notes Date PS51871423 page 1 October 31, 2023 10:49 AM Interactive Menu • Order Information page 2 • Product Specifications page 3 • Energy Data page 3 • Photometric Data page 4 • Product Warranty RA Baffle Adjustable Recessed Canless LED Downlight 4" and 5/6" Baffle Adjustable Recessed Canless LED Downlights mount directly to the ceiling and provide up to 35° of tilt and 360° of rotation Typical Applications Residential Top Product Features • Available in 4" and 6" LED trims mount directly to ceilings - no housing required • Adjustable gimbal tilts up to 35° and r otates 360° to aim light where it's needed • 6-Position Switch: 5 Color Field-SeleCC Table soft white to daylight (2700K, 3000K, 3500K, 4000K, 5000K) + Dim-to-W arm (3000K dims to 1800K) • Selectable Lumen Switch: Choose between 600/900 lumens • 5% phase cut LE/TE dimming (120V input) with compatible controls (r eference the RA Dimming Guide) Can be used to comply with Title 24 Part 6 LED Enclosed Light Source Requirements (JA8) Refer to ENERGY STAR® Certified Products List. Can be used to comply with California Title 24 High Efficacy requirements. Certified to California Appliance Efficiency Database under JA8. additional product diagrams dim-to-warm option included RA6-DM Dimensional and Mounting Details Ø 4.19" [106.4mm] CUTOUT DIAMETERØ 5.13" [130.2mm] 2.72" [69.2mm] 4.04" [102.5mm] WIRE LENGTH 35º .25" [6.4mm] 1.46" [37mm] REGRESSION Ø 7.25" [184mm] 4.04" [102.5mm] WIRE LENGTH 4.09" [103.8mm] 35º .20" [5.1mm] Ø 6.13" [155.6mm] CUTOUT DIAMETER 1.38" [35mm] REGRESSION RA4-DM RA6-DM RA4-DM Product Certification Product Features RA Canless Series PS51871423 page 3 October 31, 2023 10:49 AM Product Specifications Selectable System • Use the 6-position color selector switch to c hoose between: Dim-to-Warm (3000K dims to 1800K), 2700K, 3000K, 3500K, 4000K, and 5000K • Use the lumen select switch to c hoose the preferred brightness level Module – Trim • Module construction includes LED array , heat sink, reflector, lens, baffle and trim ring • Regressed baf fle • Heat sink designed to conduct heat away from the LED ar ray, keeping the junction temperatures below specified maximums, even when installed in insulated ceiling environments • Adjustable gimbal tilts up to 35º and rotates up to 360º LED Array • Mid power LED array pro vides a uniform source with high efficiency and no pixilation • 90 CRI minimum, R9 greater than 50 • Color accuracy at 4 SDCM in between Endpoints, provide color accuracy and uniformity . • Factory default color temperature (CCT) is set to sof t white (3000K) Optical Assembly • Regressed lens • Impact-resistant polycarbonate • Convex form and lamp-lik e appearance Driver • Integral 120V 60 Hz constant cur rent driver provides noise free operation • Inline electrical quick connect and E26 adapter (pro vided) provides mains connections • Continuous, flick er-free phase cut (leading- edge/trailing-edge - LE/TE) dimming from 100% to 5% output with compatible dimmers • *See the RA Dimming Guide for compatible dimmer s Retention • No housing or junction box required • The included remote junction box may be used in direct contact with insulation • Installer must cut template out of drywall and install into aper ture with the clips compressed • When released, the spring clips will rest on to the back side of the dryw all holding the fixture in place • Not for installation in recessed cans • For new construction applications, use HAL O Canless Mounting Frames prior to drywall installation Gasket • Closed cell gask ets achieve restrictive airflow requirements without additional caulking Compliance • UL Certified US and Canada Type IC suitable for direct contact with air permeable insulation • Damp location listed. Not recommended for use in direct contact with spray foam insulation, reference NEMA LSD57-20 13 • Airtight cer tified per ASTM-E283 • EMI/RFI emissions per FCC 47CFR Par t 15 consumer limits • Contains no mercury or lead and RoHS compliant • Photometric testing in accordance with IES LM-79-08 • Lumen maintenance projections in accordance with IES LM-80-08 and TM-21 -1 1 • Can be used for State of California T itle 24 high efficacy luminaire compliance. Complies with Title 24 J A8-2022-E. • Can be used International Energy Conservation Code (IECC) high efficiency luminaire compliance. • ENERGY ST AR® listed, reference database for current listings Warranty • Five year limited warranty, consult website for details. www.cooperlighting.com/warranty Energy Data RA6LS9FSD2W1EWHDM - 3000K Catalog Number CCT Watts lumens LPW CRI RA6LS9FSD2W1EWHDM 600 Lumens 2700K 6.3 650 103.2 93 3000K 6.3 630 100.0 93 3500K 6.3 670 106.3 93 4000K 6.3 675 107.1 93 5000K 6.3 675 107.1 93 Catalog Number CCT Watts lumens LPW CRI RA6LS9FSD2W1EWHDM 900 Lumens 2700K 9.6 920 95.8 93 3000K 9.5 950 100.0 93 3500K 9.6 950 99.0 93 4000K 9.6 960 100.0 93 5000K 9.5 955 100.5 93 RA4LS9FSD2W1EWHDM - 3000K Catalog Number CCT Watts lumens LPW CRI RA4LS9FSD2W1EWHDM 600 Lumens 2700K 6.1 615 100.8 92 3000K 6.2 620 100.0 93 3500K 6.1 635 104.1 93 4000K 6.1 630 103.3 93 5000K 6.1 630 103.3 93 Catalog Number CCT Watts lumens LPW CRI RA4LS9FSD2W1EWHDM 900 Lumens 2700K 9.2 885 96.2 92 3000K 9.2 920 100.0 93 3500K 9.4 910 96.8 93 4000K 9.3 905 97.3 93 5000K 9.3 900 96.8 93 Lumens 600/900 Input Voltage 120V Input current 0.08A/0.05A Input Power 9.3W/6.1W Efficiency 76.64%/77.33% Inrush(A) 1.94 THD 16/12.2 PF 0.949/0.975 Sound Rating <=22dba Lumens 600/1000 Input Voltage 120V Input current 0.053A/0.079A Input Power 6.13W/9.32W Efficiency 76.64%/77.33% Inrush(A) 1.94 THD 16/12.2 PF 0.949/0.975 Sound Rating <=22dba PS51871423 page 4 October 31, 2023 10:49 AM RA Baffle Adjustable Recessed Canless LED Downlight Cooper Lighting Solutions 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.cooperlighting.com © 2023 Cooper Lighting Solutions All Rights Reserved. Specifications and dimensions sub- ject to change without notice. Photometric Data 22CZ2-24-UNVL830-CD1-U Electronic Driver Linear LED 5000K Spacing criterion: (II) 1.23 x mounting height, (⊥) 1.23 x mounting height Lumens: 11493 Input Watts: 87.7W Efficacy: 131.1 LPW Test Report: 22CZ2-24-UNVL830- CD1-U.IES 22CZ2-24-UNVL830-CD1-U Electronic Driver Linear LED 5000K Spacing criterion: (II) 1.23 x mounting height, (⊥) 1.23 x mounting height Lumens: 11493 Input Watts: 87.7W Efficacy: 131.1 LPW Test Report: 22CZ2-24-UNVL830- CD1-U.IES 0-deg 45-deg 90-deg 180° 170°160° 150° 140° 130° 120° 110° 100° 90° 80° 70° 60° 50° 40° 30°20°10°0° 489 367 245 122 0 0-deg 45-deg 90-deg 180° 170°160° 150° 140° 130° 120° 110° 100° 90° 80° 70° 60° 50° 40° 30°20°10°0° 460 345 230 115 0 RA4LS9FSD2W1EWHDM-900lm- 3000K Spacing criterion: (0-180) 1.09 | (90-270) 1.09 | (Diagonal) 1.14 Beam Angle: 81° Field Angle: 141° Lumens: 920 Input Watts: 9.2 W Efficacy: 100 LPW UGR: 20 Test Report: P710078 RA6LS9FSD2W1EWHDM-900lm- 3000K Spacing criterion: (0-180) 1.12 | (90-270) 1.12 | (Diagonal) 1.19 Beam Angle: 86° Field Angle: 147° Lumens: 950 Input Watts: 9.5 W Efficacy: 100 LPW UGR: 19 Test Report: P710098 Zonal Lumen Lumens % Lumens 0-30 351 38.2 0-40 537 58.3 0-60 807 87.7 0-90 920 100 Zonal Lumen Lumens % Lumens 0-30 336 35.3 0-40 522 55 0-60 816 85.9 0-90 950 100 TM-30-15 Rf = 91 Rg = 103 CRI/CIE Ra = 94.6 R9 = 74.6 TM-30-15 Rf = 93 Rg = 101 CRI/CIE Ra = 96.9 R9 = 81.3 81° 86° Project Catalog # Type Prepared by Notes Date PS514255325EN page 1 September 30, 2025 3:44 PM • Available in 12W, 18W, 26, & 38W (900 - 3,100 lumens) models • Av ailable in 5000K or 4000K (CCT) • Wall, inv erted or pole mount • Energy and maintenance sa vings up to 95% compared to HID • Energy efficient illumination r esults in up to 177LPW • Replaces 70W up to 450W HID equiv alents • Optional floodlighting kit conver ts from wall to floodlight, and pole mount Interactive Menu • Ordering Information page 2 • Product Specifications page 2 • Energy and Performance Data page 3 Dimensional Details Wall Mount Luminaire Lumark Crosstour Series Product Certifications & Features 12W, 18W, 26W 5-3/4" [146mm] 38W 6-5/8" [168mm] 12W, 18W, 26W 6-3/4" [171mm] 38W 8" [203mm] 12W, 18W, 26W 3-5/8" [92mm] 38W 4" [102mm] 8-3/4" [222mm] 6-1/4" [159mm] 11" [279mm] 17-1/2" [445mm] 10" [254mm] 10" [254mm] 17-1/2" [445mm] 19-1/4" [489mm] 19-1/4" [489mm] Crosstour Full Cut-off Crosstour MAXX Full Cut-off Crosstour Escutcheon Plates Crosstour MAXX Escutcheon Plate Quick Facts © 2016 Axis Lighting Inc. 1.800.263.2947 [T] 5 14.948.6272 Product design and development is an ongoing process at Axis Lighting.We reserve the right to change specifications. Contact Axis for the latest product information. 1 / 6 FILE NAME:EX2S.SPEC November 18, 2025 axislighting.com EX2S PRODUCT ID NOM. LUM/FT CRI COLOR TEMP . (choose one) SHIELDING EX2S Extend 2 Surface 300 300 lm/ft - min 80 80 CRI 27 2700 K SO spotless lens 750 750 lm/ft - max for 90 90 CRI 30 3000 K GZ Graze GZ, WW, ASO* 35 3500 K WW Wallwash 1000 1000 lm/ft - max 40 4000 K ASO Asymmetric 50 5000 K BW Batwing Outputs between listed min and max are available. * 750 lm/ft max. only for GZ, WW and ASO. Consult factory for outputs outside of the listed range. Choose only one of the options above; LENGTH (FT) FINISH VOLTAGE DRIVER CIRCUITS 2 2’ AP aluminum paint 120 120 V DP dimming (0-10V) 1% 1 1 circuit 3 3’ W white 277 277 V temp. range -22°F - +104°F (-30°C - +40°C) 2 2 circuits 4 4’ BLK black 347 347 V* DPX dimming (0-10V) 1%, extended +E(#) emergency circuit* 5 5’ C custom UNV universal temp. range -40°F - +122°F (-40°C - +50°C) +NL(#) night light circuit* 6 6’ LT(#) Lutron* +GTD(#) generator transfer 7 7’ BI bi-level dimming device* ** 8 8’ O(#) other* 12 12’ S(L) System Run Lengths are nominal. Exact lengths can be specified, please consult factory. *Remote surge protection device only Integral drivers standard, remote drivers available for environments outside of driver operating temperature range or where fixture access may be limited. See page 2 for more details. * Please consult factory; see page 2. *Specify quantity. Minimum 3ft fixture length. **120V and 277V only. Please specify. MOUNTING BATTERY (OPTIONAL) OTHER (OPTIONAL) CUSTOM (OPTIONAL) SB surface bracket B(#) battery pack (integral)* +EF end feed* C custom S surface ceiling* BR(#) battery pack (remote)** +N natatorium finish SBBP surface bracket with bird protection * Requires opening fixture for installation. *Minimum 3ft; **Dry/Damp location only. Please consult factory. * End Feed standard for S mounting Please specify Notes Type Project Ordering Guide Surface mountExtend 2 NOMINAL LUMEN OUTPUT INPUT WATTS* EFFICACY SHIELDING 1000 lm/ft 9.8 W/ft 101 lm/W SO 750 lm/ft 7.2 W/ft 103 lm/W GZ 750 lm/ft 7.4 W/ft 101 lm/W ASO 1000 lm/ft 9.7 W/ft 102 lm/W BW 750 lm/ft 7.4 W/ft 101 lm/W WW *Please consult factory for custom lumen output and wattage. PERFORMANCE PER LINEAR FOOT AT 3500K, 80 CRI SHIELDING DIRECT Spotless Lens SO Wall Wash WW Graze GZ Asymmetric ASO Batwing BW 2 13/16" 2 1/2" 3/4" Lumark Crosstour Series PS514255325EN page 2 September 30, 2025 3:44 PM Crosstour Stock Ordering Information Ordering Information SAMPLE NUMBER: XTOR2B-W-WT-PC1 Domestic Preferences Series 1 LED Kelvin Color Housing Color Options (Add as Suffix) Accessories (Order Separately) [Blank]=Standard BAA=Buy American Act 7 TAA=Trade Agreements Act 7 BABA=Build America Buy America Act 8 XTOR1B=Small Door, 12W XTOR2B=Small Door, 18W XTOR3B=Small Door, 26W XTOR4B=Medium Door, 38W [Blank]=Bright White (Standard), 5000K W=Neutral White, 4000K Y=Warm White, 3000K [Blank]=Carbon Bronze (Standard) WT=Summit White BK=Black BZ=Bronze AP=Grey GM=Graphite Metallic DP=Dark Platinum PC1=Photocontrol 120V 2 PC2=Photocontrol 208-277V 2, 3 347V=347V 4 HA=50ºC High Ambient 4 XTORFLD-KNC=Knuckle Floodlight Kit 6 XTORFLD-TRN=Trunnion Floodlight Kit 6 XTORFLD-KNC-WT=Knuckle Floodlight Kit, Summit White 6 XTORFLD-TRN-WT=Trunnion Floodlight Kit, Summit White 6 EWP/XTOR=Escutcheon Wall Plate, Carbon Bronze EWP/XTOR-WT=Escutcheon Wall Plate, Summit White Full Cutoff XTOR6B=MAXX, 58W XTOR8B=MAXX, 81W XTOR12B=MAXX, 102W Refractive Lens XTOR6BRL=MAXX, 58W XTOR8BRL=MAXX, 81W XTOR12BRL=MAXX, 102W 347V=347V 9, 10, 11, 12 480V=480V 9, 10, 11, 12, 13 PC1=Photocontrol 120V 7 PC2=Photocontrol 208-277V 14, 15 PMA=Pole Mount Arm (C Drilling) with Round Adapter 10, 16 MS-L20=Motion Sensor for ON/OFF Operation 9, 10, 17, 18 MS/DIM-L20=Motion Sensor for Dimming Operation 9, 10, 17, 18, 19, 20, 21 CBP=Cold Weather Battery Pack 9, 10, 22, 23, 24 HA=50ºC High Ambient 24 WG-XTORMX=Crosstour MAXX Wire Guard PB120V=Field Installed 120V Photocontrol PB277V BUTTON PC=Field Installed 208-277V Photocontrol 15 VA1040-XX=Single Tenon Adapter for 3-1/2” O.D. Tenon 25 VA1041-XX=2@180° Tenon Adapter for 3-1/2” O.D. Tenon 25 VA1042-XX=3@120° Tenon Adapter for 3-1/2” O.D. Tenon 25 VA1043-XX=4@90° Tenon Adapter for 3-1/2” O.D. Tenon 25 VA1044-XX=2@90° Tenon Adapter for 3-1/2” O.D. Tenon 25 VA1045-XX=3@90° Tenon Adapter for 3-1/2” O.D. Tenon 25 VA1046-XX=2@120° Tenon Adapter for 3-1/2” O.D. Tenon 25 VA1033-XX=Single Tenon Adapter for 2-3/8” O.D. Tenon 25 VA1034-XX=2@180° Tenon Adapter for 2-3/8” O.D. Tenon 25 VA1035-XX=3@120° Tenon Adapter for 2-3/8” O.D. Tenon 25 VA1036-XX=4@90° Tenon Adapter for 2-3/8” O.D. Tenon 25 VA1037-XX=2@90° Tenon Adapter for 2-3/8” O.D. Tenon 25 VA1038-XX=3@90° Tenon Adapter for 2-3/8” O.D. Tenon 25 VA1039-XX=2@120° Tenon Adapter for 2-3/8” O.D. Tenon 25 EWP/XTORMX=Escutcheon Wall Plate, Carbon Bronze EWP/XTORMX-WT=Escutcheon Wall Plate, Summit White FSIR-100=Wireless Configuration Tool for Occupancy Sensor 14 NOTES: 1. De signLights Consortium® Qualified and classified for both DLC Standard and DLC Premium, refer to designlights.org for details. 2. Ph otocontrols are factory installed. 3. Or der PC2 for 347V models. 4. Th ru-branch wiring not available with HA option or with 347V. XTOR3B not available with HA and 347V or 120V combination. 5. Wi re guard for wall/surface mount. Not for use with floodlight kit accessory. 6. Fl oodlight kit accessory supplied with knuckle (KNC) or trunnion (TRN) base, small and large top visors and small and large impact shields. 7. On ly product configurations with these designated prefixes are built to be compliant with the Buy American Act of 1933 (BAA) or Trade Agreements Act of 1979 (TAA), respectively. Please refer to DOMESTIC PREFERENCES website for more information. Components shipped separately may be seperately analyzed under domestic preference requirements. 8. On ly product configurations with these prefixes are built to be compliant with the Buy American Act of 1933 (BAA) or the Build America Buy America Act (BABA). BABA is the minimum Government compliance requirement for the Build America Buy America standards which is part of the Infrastructure and Investment Jobs Act (IIJA). Individual Government Agencies may have more stringent compliance standards. Please refer to the DOMESTIC PREFERENCES website or consult the CLS Domestic Preferences team for more information. Components shipped separately may be separately analyzed under domestic preference requirements. 9. No t available with HA option. 10. De ep back box is standard for 347V, 480V, CBP, PMA, MS-L20 and MS/DIM-L20. 11. No t available with CBP option. 12. Th ru-branch wiring not available with HA option or with 347V. 13. On ly for use with 480V Wye systems. Per NEC, not for use with ungrounded systems, impedance grounded systems or corner grounded systems (commonly known as Three Phase Three Wire Delta, Three Phase High Leg Delta and Three Phase Corner Grounded Delta systems). 14. No t available with MS-L20 and MS/DIM-L20 options. 15. Us e PC2 with 347V or 480V option for photocontrol. Factory wired to 208-277V lead. 16. Cu stomer is responsible for engineering analysis to confirm pole and fixture compatibility for all applications. Refer to our white paper WP513001EN for additional support information. 17. Fo r use in downlight orientation only. Optimal coverage at mounting heights of 9’-20’. 18. 12 0V thru 277V only. 19. Fa ctory set to 50% power reduction after 15-minutes of inactivity. Dimming driver included. 20 . In cludes integral photo sensor. 21. Th e FSIR-100 configuration tool is required to adjust parameters including high and low modes, sensitivity, time delay, cutoff, and more. Consult your lighting representative at Eaton for more information. 22. 12 0V or 277V operation only. 23. Op erating temperatures -20°C to 25°C. 24. No t available in XTOR12B or XTOR12BRL models. 25. Re place XX with housing color. 12W Series 18W Series 26W Series 38W Series XTOR1B=12W, 5000K, Carbon Bronze XTOR2B=18W, 5000K, Carbon Bronze XTOR3B=26W, 5000K, Carbon Bronze XTOR4B=38W, 5000K, Carbon Bronze XTOR1B-WT=12W, 5000K, Summit White XTOR2B-W=18W, 4000K, Carbon Bronze XTOR3B-W=26W, 4000K, Carbon Bronze XTOR4B-W=38W, 4000K, Carbon Bronze XTOR1B-PC1=12W, 5000K, 120V PC, Carbon Bronze XTOR2B-WT=18W, 5000K, Summit White XTOR3B-WT=26W, 5000K, Summit White XTOR4B-WT=38W, 5000K, Summit White XTOR1B-W=12W, 4000K, Carbon Bronze XTOR2B-PC1= 18W, 5000K, 120V PC, Carbon Br onze XTOR3B-PC1= 26W, 5000K, 120V PC, Carbon Br onze XTOR4B-PC1= 38W, 5000K, 120V PC, Carbon Br onze XTOR2B-W-PC1= 18W, 4000K, 120V PC, Carbon Br onze XTOR3B-W-PC1=26W, 4000K, 120V PC, Carbon Bronze XTOR4B-W-PC1= 38W, 4000K, 120V PC, Carbon Bronze XTOR2B-347V= 18W, 5000K, Carbon Br onze, 347V XTOR3B-347V=26W, 5000K, Carbon Bronze, 347V XTOR4B-347V=38W, 5000K, Carbon Bronze, 347V XTOR2B-WT -PC1=18W, 5000K, 120V PC, Summit White XTOR3B-PC2=26W, 5000K, 208-277V PC, Carbon Bronze © 2016 Axis Lighting Inc. 1.800.263.2947 [T] 5 14.948.6272 Product design and development is an ongoing process at Axis Lighting.We reserve the right to change specifications. Contact Axis for the latest product information. 2 / 6 FILE NAME:EX2S.SPEC November 18, 2025 axislighting.com Surface mountExtend 2 CONSTRUCTION Housing Extruded aluminum (0.08'' nominal) Up to 70% recycled content End Cap Cast aluminum Interior Brackets Die formed sheet steel (18 gauge) Gaskets Silicone rubber Lens Gaskets Extruded elastomer Lens Extruded acrylic Fasteners All external fasteners are tamper proof TORX T20 OPTICS SO Spotless lens; ASO Asymmetric Spotless lens; WW Wallwash; BW Batwing; GZ Graze. WEIGHT 4 ft 7 lbs / 3.2 kg 8 ft 14 lbs / 6.4 kg 12 ft 21 lbs / 9.6 kg FINISH Powder coated, custom finishes are available. EXTEND 2 is also available with pendant, wall and recessed mount options. Specification sheets and installation sheets for all mountings for EXTEND 2 luminaires are available for download at www.axislighting.com OTHER MOUNTING OPTIONS Impact modified PMMA lens used for all shielding options. Lengths of 2'-12' standalone are available. Runs of EXTEND2 that are greater than 12’ in length are designated as systems (S(L)). System runs are comprised of a combination of 4’ to 8’ sections to be assembled on site using our joining system which includes a 1” sealed joiner plate. For more information on systems and joining, please refer to the EXTEND2 installation sheets available for download at www.axislighting.com. SYSTEM (S(L)) 1" Limited 5-year warranty is available. Warranty is valid provided luminaires are installed and used according to specifications. For full terms and conditions, please consult warranty section at axislighting.com. WARRANTY APPROVALS Certified wet locations to UL and CUL standards. IP66 and IK10 rated. ELECTRICAL DP DPX 0-10V dimming driver. Ambient operating temperature -22°F - 104°F (-30°C - +40°C) 0-10V dimming driver with extended temperature range -40°F - 122°F (-40°C - +50°C) Lutron driver** LDE1 - Hi-lume 1% EcoSystem with Soft-on, Fade-to- Black (min ambient operating temperature - 32°F (0°C). Other drivers** DALI* - Digital Addressable Lighting Interface DMX* - Digital Multiplex Xitanium SR* - For wireless sensor Emergency B(#) Integral Emergency Battery pack, 3ft minimum. Ambient operating temperature -4°F - 122°F(-20° to 50°C) for 120V to 277V; 32°F - 122°F (0°C to 50°C) for 347V BR(#) Remote emergency battery pack operating temperature range -4°F - 122°F (-20°C- +50°C) for 120V to 277V; 32°F - 122°F (0°C - +50°C) for 347V. Input Voltage 120V, 277V, 347V, UNV. Surge Protection Extend comes standard with surge protection device. Incorporating these components may have limitations or affect the length of the luminaire. Please contact factory for more details. * Ambient operating range: -4°F - 104°F (-20°C - +40°C) **Remote only with EX2PDI. LED SYSTEM CRI Minimum 80 or 90 color rendering index. CCT Single Color Choice of 2700K, 3000K, 3500K, 4000K and 5000K color temperature with a great color consistency (within 3–step MacAdam ellipse). Both within fixture and fixture to fixture. LED life Minimum 50,000h with 85% of lumen maintenance in 25 0C ambient temperature, in compliance with IES LM-80 testing measurements. Thermal Management Aluminum housing acting as the heat sink to maximize life. Environment Dry and wet location rated IP66 for outdoor or indoor use. Impact resistant rated IK10. For extreme temperature environments, please contact factory. Remote drivers available for environments outside of driver operating temperature range or where fixture access may be limited. Ambient operating temperature range for fixtures with remote drivers -40°F to +167°F (-40°C - +75°C). © 2016 Axis Lighting Inc. 1.800.263.2947 [T] 5 14.948.6272 Product design and development is an ongoing process at Axis Lighting.We reserve the right to change specifications. Contact Axis for the latest product information. 5 / 6 FILE NAME:EX2S.SPEC November 18, 2025 axislighting.com All IES files for other lamping are available for download at: www.axislighting.com LUMINANCE DATA (cd/m 2) Horizontal Angles Vertical Angle 0 45 90 45 10630 9359 11321 55 8858 8728 11689 65 7462 7806 11399 75 6114 6524 8813 85 3919 4146 3429 Lumen/ft: 750 lm/ft Total Lumens: 2987 lm (for 4ft) Input Watts: 29.6 W Efficacy: 101 lm/W IES FILE: EX2S-750-80-35-WW-4.IES TESTED ACCORDING TO IES LM-79-2019 750 lm/ft Horizontal Angles Vertical Angle 0 22.5 45 67.5 90 0 1232 1232 1232 1232 1232 5 1222 1149 1097 1057 1052 15 1134 948 852 807 797 25 965 752 693 686 690 35 751 584 578 611 634 45 535 440 471 535 570 55 362 313 356 437 477 65 224 203 235 312 343 75 113 103 120 156 162 85 24 23 26 22 21 90 3 4 4 3 3 CANDELA DISTRIBUTION ZONAL LUMENS Lumens Zone 0 0-10 117 10-20 342 20-30 541 30-40 610 40-50 527 50-60 404 60-70 274 70-80 139 80-90 33 90 PHOTOMETRIC CURVE 90º 60º 30º0º ° 30°0° 90° 0 ° 1994 1496 997 499 WW Walwash LUMINANCE DATA (cd/m 2) Horizontal Angles Vertical Angle 0 45 90 45 10630 9359 11321 55 8858 8728 11689 65 7462 7806 11399 75 6114 6524 8813 85 3919 4146 3429 Lumen/ft: 750 lm/ft Total Lumens: 2987 lm (for 4ft) Input Watts: 29.6 W Efficacy: 101 lm/W IES FILE: EX2S-750-80-35-ASO-4.IES TESTED ACCORDING TO IES LM-79-2019 750 lm/ft Horizontal Angles Vertical Angle 0 22.5 45 67.5 90 0 1232 1232 1232 1232 1232 5 1222 1149 1097 1057 1052 15 1134 948 852 807 797 25 965 752 693 686 690 35 751 584 578 611 634 45 535 440 471 535 570 55 362 313 356 437 477 65 224 203 235 312 343 75 113 103 120 156 162 85 24 23 26 22 21 90 3 4 4 3 3 CANDELA DISTRIBUTION ZONAL LUMENS Lumens Zone 0 0-10 117 10-20 342 20-30 541 30-40 610 40-50 527 50-60 404 60-70 274 70-80 139 80-90 33 90 PHOTOMETRIC CURVE 90º 60º 30º0º ° 30°0° 90° 0 ° 1994 1496 997 499 ASO Asymmetric PHOTOMETRIC DATA Surface mountExtend 2 Lumark Crosstour Series PS514255325EN page 4 September 30, 2025 3:44 PM Crosstour MAXX Power and Lumens LED Information XTOR6B XTOR6BRL XTOR6B-W XTOR6BRL-W XTOR6B-Y XTOR6BRL-Y Delivered Lumens 6,129 6,225 6,038 6,133 5,611 5,826 B.U.G. Rating B1-U0-G1 B2-U4-G3 B1-U0-G1 B2-U4-G3 B1-U0-G1 B2-U4-G3 CCT (Kelvin) 5000K 5000K 4000K 4000K 3000K 3000K CRI (Color Rendering Index) 70 70 70 70 70 70 Power Consumption (Watts) 58W 58W 58W 58W 58W 58W LED Information XTOR8B XTOR8BRL XTOR8B-W XTOR8BRL-W XTOR8B-Y XTOR8BRL-Y Delivered Lumens 8,502 8,635 8,373 8,504 7,748 8,079 B.U.G. Rating B2-U0-G1 B2-U4-G3 B2-U0-G1 B2-U4-G3 B2-U0-G1 B2-U4-G3 CCT (Kelvin) 5000K 5000K 4000K 4000K 3000K 3000K CRI (Color Rendering Index) 70 70 70 70 70 70 Power Consumption (Watts) 81W 81W 81W 81W 81W 81W LED Information XTOR12B XTOR12BRL XTOR12B-W XTOR12BRL-W XTOR12B-Y XTOR12BRL-Y Delivered Lumens 12,728 13,458 12,539 13,258 11,861 12,595 B.U.G. Rating B2-U0-G1 B2-U4-G3 B2-U0-G1 B2-U4-G3 B2-U0-G1 B2-U4-G3 CCT (Kelvin) 5000K 5000K 4000K 4000K 3000K 3000K CRI (Color Rendering Index) 70 70 70 70 70 70 Power Consumption (Watts) 102W 102W 102W 102W 102W 102W Energy and Performance Data Crosstour Power and Lumens LED Information XTOR1B XTOR1B-W XTOR1B-Y XTOR2B XTOR2B-W XTOR2B-Y XTOR3B XTOR3B-W XTOR3B-Y XTOR4B XTOR4B-W XTOR4B-Y Delivered Lumens (Wall Mount) 1,418 1,396 1,327 2,135 2,103 1,997 2,751 2,710 2,575 4,269 4,205 3,995 Delivered Lumens (With Flood Accessory Kit) 1 1,005 990 940 1,495 1,472 1,399 2,099 2,068 1,965 3,168 3,121 2,965 B.U.G. Rating 2 B1-U0-G0 B1-U0-G0 B1-U0-G0 B1-U0-G0 B1-U0-G0 B1-U0-G0 B1-U0-G0 B1-U0-G0 B1-U0-G0 B2-U0-G0 B2-U0-G0 B2-U0-G0 CCT (Kelvin) 5,000 4,000 3,000 5,000 4,000 3,000 5,000 4,000 3,000 5,000 4,000 3,000 CRI (Color Rendering Index) 70 70 70 70 70 70 70 70 70 70 70 70 Power Consumption (Watts) 12W 12W 12W 18W 18W 18W 26W 26W 26W 38W 38W 38W NOTES: 1 Includes shield and visor. 2 B.U.G. Rating does not apply to floodlighting. A.1.5SECOND FLOOR REFLECTED CEILING PLAN SCALE: 1/8" = 1'-0" 1 A.1.5 FIXTURE "A" FIXTURE "B" FIXTURE "C" FIXTURE "D" 7 Z2IEE7.773 i i i i LITE I Product Features product Certification -----­le.el. . . .. . - 4 and 5/6 Baffle Adjustable Recessed Canless LED Downlights mount directly to the ceiling and provide up to 35 of tilt and 360 of rotation Tie.al iplie.sties HALO RA Baffle Adjustable Recessed Canless LED Downlight p Interactive Menu Order information eaProduct Specifications aa Energy Data aphotometric Data eaProduct Warranty Top Product Features goLo·-­ttit -5MAr Psst8.714.23 page1 • Available in 4 and6 LED trims mount directly to ceilings - no housing required • Adjustable gimbal tilts up to 35" and rotates 30 to aim light where it's needed 6position Switch. 5 Color Field-SeleccTable soft white to daylight (2700K. 3000K, 3500K, 4000K, 5000K) + Dim-to-Warm (3000K dims to 1800K) Selectable Lumen Switch. Choose between 600/900 umens • 5%phase cut LETE dimming (120y input) with compatible controls (reference the RA Dimming Guide) -, r-.. r-.. .'-' '-' ......,,Dimensional and Mounting Details O COOPERLighting.it n aI I I I - - - - HI • ) I H I t I I J , / I I ul C I I- - - - - - - ek : [ 0 ~ J 0 r__. 7 J 0 0 0 0 0 0 ...II L I 0 I [ L I I- [ ek H H _J H r1--1~ sEcTON Ew scTON WEw FRONT EW H,ptmo) RoNT WEw Megablinker $60.20 itorerttietote. hi.2 Meniblinker S6070 itorerttietote. hi.7 scTON WEw '.'to5 mom) EcTo w FRONT EW rRoNT yEw Blinker S6080 itcotie, tote. hi.3 BLINKER I" DIMENSIONS Miroblinker s6060 RESET INFO [ Psst 4.298900 petpeer o. 20.$dpo []20saritoe Miegablinker []s020-2oox. oocRo [so2ow.soookoocre []8020N- «oook. soc eriurm []or.-on []o»-sos lanker [s60on -2rook.oocre [siowwisc][soot - «oook. soc []24oco9a DOMMNG 0to-oov VOLTAGE uwv.2o-27v sen-gee;e"teosaao743rt7 nag2,%g2-trtsw-gee,/,e"goro(1ton 3om r 13nm) so-gee//pgoo»(7om r 3om r tone MOUNTING ACCESSORIES topart.. hicroblinker Miniblinker []so-zoo.oocno [so70.zoo.ooco [sos@w.soook.oocnu [sso7ow.soookoocre []s60oN-«ooo.soc [9o7ow.«0oo. eocRo • UNV • • D10 ORDERING INFO Crest tour pteek Ordering hfermattion .r .7 r 2I Jnon.pitatee iro.•tattee. ire2,toe. irotitornroopti• iro.itrtatto yr..ittot,ateto yo.ittatto hoc«issoot,ca ironsroar,orow ironsroaro,erwoe iroasroarooo, sotwoe •i.zEgg IEEE.""he lbhrhetht toeit ••z...""-,_------.-­zz:zz7---- :zzz::z7-.-------t •lit e eet:.zzzz.:...7.:z------iiit•• h•,.telt.trtt ii ••iE±zEu=ZEE_ZEE_Ens.lEEEEE=tlietr tr. Ordering Information I" FINISH Standard []ot-w [«o] I 9es&@pg JD■■■ II I I I I 0 I I 61] I=H] 0 7pp t 1 I I 4I I ~I ass77rrt $14.9as.8272 0 to hhtutbot. hi.rt, e•toc}htest.hi.3.1pp4hi03,pig woo• Surface mount I I I ##2% %# I ##2%% %21# SISTEMALUX (e Extend 2 asst20it Loge.t.00.232947rt $14.9ass272 /e (e 0 [e t•g hhtutbot. hi.rt, e•toa.}htest.h3.1pg# p4hi03,pig woo• Surface mount /e 0 I htlsioer•tirt• SISTEMALUX /e /e Extend 2 (e [e [e lo assaistinting.com 77rrt $14.9as.8272 PERFORMANCE PER LUNEAR F0OT Ar 3500K. 9 cRI §--M -• ri# b9wt t0ti lo i# 12wt 103iw /ft 7tit 10tie/ i# h97wt to2iw By /ft 7tit 10tie/ pon.ult hctony or ustore knee output and watt.ae. Project Type Notes puv diet0-0) 1% temp. nae-22f-»tat.or-oatopining•ptended « emergency circuit temp. aea%-122far-oioro +tunny night hight oroar tot «rps. generator trashier itdoing deotee To.choose one) #± Surface mount I ,,. I oweenter 1. 20.2 taetoit to too0 it-- ma uroroouu ororio#au ustoouurtebaiet battery pair ta aped istr"Cg] on eaeo ·oooorot»edacebacioet weth bind. protection ti2i bet kotoe b 300it-mi t 0Rr»row. [Hege] Ordering Guide SISTEMALUX Extend 2 Page 21 of 68 A R CH ITECT S A R CH ITECT S parkerdesigngrouparchitects 843 785 5171 POST OFFICE BOX 5010 HILTON HEAD ISLAND SC 29938 A RENOVATION FOR : REVISIONS DATE OF ISSUE: TP SHEET OF SHEETS TP SCALE DRAWN BY CHECKED BY JOB NO. 2/25/26 HILTON HEAD , S.C. SERG GROUP THE ATRIUM BUILDING These documents & designs are the property of Parker Design Group | Architects & are not to be used or reproduced there of or for designs, working drawings, or construction of buildingswithout the written authorization from the copy write owner PDG|Architects 2024 copyright C EXISTING SLOPE 1/2"1'-0" 1/2"1'-0" 1/2"1'-0" 1/2"1'-0" 1/2"1'-0" 1/2"1'-0" 1/2"1'-0" 1/2"1'-0" 1/2" 1'-0" 1/2" 1'-0" 1/2" 1'-0" 1/2"1'-0" 1/2"1'-0" NEW TPO ROOF SYSTEM ON EXISTING ROOF STRUCTURE EXISTING SLOPE 1/4"1'-0" 1/2" 1'-0" 1/2" 1'-0" 1/2" 1'-0" 1/2" 1'-0" 1/2" 1'-0" 1/2" 1'-0" 1/2" 1'-0" 1/2" 1'-0"1/2" 1'-0"1/2" 1'-0" 1/2" 1'-0" NEW TPO ROOF SYSTEM UNDER PAVER PEDESTAL SYSTEM NEW PARAPET WALL ON THIS END TO BE LEVEL WITH WALLS ON FRONT AND BACK NEW PARAPET WALL ON THIS END TO BE LEVEL WITH WALLS ON FRONT AND BACK NEW TPO ROOF SYSTEM ON EXISTING ROOF STRUCTURE NEW STANDING SEAMED METAL ROOF PANELS ON EXISTING ROOF STRUCTURE ALUM. COPING ON NEW PARAPET GABLE END ALUM. COPING ON NEW PARAPET GABLE END RIDGE NEW STANDING SEAMED METAL ROOF PANELS ON EXISTING ROOF STRUCTURE NEW STANDING SEAMED METAL ROOF PANELS ON EXISTING ROOF STRUCTURE 6 12 NEW CANOPY OVER EXISTING STAIR LANDING A.1.6 ROOF PLAN SCALE: 1/8" = 1'-0" 1 A.1.6 Page 22 of 68 A R CH ITECT S A R CH ITECT S parkerdesigngrouparchitects 843 785 5171 POST OFFICE BOX 5010 HILTON HEAD ISLAND SC 29938 A RENOVATION FOR : REVISIONS DATE OF ISSUE: TP SHEET OF SHEETS TP SCALE DRAWN BY CHECKED BY JOB NO. 2/25/26 HILTON HEAD , S.C. SERG GROUP THE ATRIUM BUILDING These documents & designs are the property of Parker Design Group | Architects & are not to be used or reproduced there of or for designs, working drawings, or construction of buildingswithout the written authorization from the copy write owner PDG|Architects 2024 copyright C ALUMINUM LOUVERS OVER STOREFRONT WINDOWS - DARK BRONZE NEW STUCCO FRONT SW 7015 REPOSE GRAY ACCOYA WOOD RAINSCREEN NANA WALL FOLDING DOOR SYSTEM - DARK BRONZE ACCOYA WOOD RAINSCREEN NANA WALL FOLDING DOOR SYSTEM - DARK BRONZE NEW PAC CLAD ROOFING- DARK BRONZE NEW TRIM SW 9170 ACIER STAINLESS STEEL CABLE ON ALUM. POSTS AND RAILS- DARK BRONZE A.2.1EXISTING ENTRANCE ELEV. SCALE: 3/16" = 1'-0" 1 A.2.1 NEW ENTRANCE ELEV. SCALE: 3/16" = 1'-0" 2 INSPIRATIONAL PHOTOS A.2.1 EXISTING ENTRY PHOTO n I I I I ~ I - l f ' I !me Pe b 0 t r 2 --- ---t) • % I I I I I I I I ' I I I I I I I I I I I I I I I I I I I I I I I I I = =1f.all1% I7 I-~He ======= 4$7$%$99$9$9$9$99$9$029%%4$25%9%0%4$9$9$9$9$29$999%9%5%4$97%$9$9%909%$% 0 Page 23 of 68 A R CH ITECT S A R CH ITECT S parkerdesigngrouparchitects 843 785 5171 POST OFFICE BOX 5010 HILTON HEAD ISLAND SC 29938 A RENOVATION FOR : REVISIONS DATE OF ISSUE: TP SHEET OF SHEETS TP SCALE DRAWN BY CHECKED BY JOB NO. 2/25/26 HILTON HEAD , S.C. SERG GROUP THE ATRIUM BUILDING These documents & designs are the property of Parker Design Group | Architects & are not to be used or reproduced there of or for designs, working drawings, or construction of buildingswithout the written authorization from the copy write owner PDG|Architects 2024 copyright C ACCOYA WOOD RAINSCREEN ACCOYA WOOD SERVICE YARD NEW METAL AWNING OVER EXISTING STAIRS IN - DARK BRONZE NEW STOREFRONT WINDOWS - DARK BRONZE NEW STUCCO FRONT SW 7015 REPOSE GRAY ADD PARAPET WALL ON THE FRONT DOWNSPOUTS AND SCUPPERS IN SW 9170 ACIER ALUMINUM LOUVERS OVER STOREFRONT WINDOWS - DARK BRONZE A.2.2EXISTING WILLIAM HILTON PKWY. ELEV. SCALE: 3/16" = 1'-0" 1 A.2.2 NEW WILLIAM HILTON PKWY. ELEV. SCALE: 3/16" = 1'-0" 2 MASSING MODEL A.2.2 EXISTING WILLIAM HILTON PKWY PHOTOS n I 0 [-]- - -- -- -- r - - -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- ~ - -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- ~ - - - -----....___ - - -- -- -- -- -- - a Ee %% - KUY SCOTT, CCIM ...!=~~~""' ------~ ~------- 0 Page 24 of 68 A R CH ITECT S A R CH ITECT S parkerdesigngrouparchitects 843 785 5171 POST OFFICE BOX 5010 HILTON HEAD ISLAND SC 29938 A RENOVATION FOR : REVISIONS DATE OF ISSUE: TP SHEET OF SHEETS TP SCALE DRAWN BY CHECKED BY JOB NO. 2/25/26 HILTON HEAD , S.C. SERG GROUP THE ATRIUM BUILDING These documents & designs are the property of Parker Design Group | Architects & are not to be used or reproduced there of or for designs, working drawings, or construction of buildingswithout the written authorization from the copy write owner PDG|Architects 2024 copyright C NEW ROOF OVER THE EXISTING DOOR DARK BRONZE ACCOYA WOOD SERVICE YARD NEW CODE COMPLIANT GUARD AND HANDRAIL- DARK BRONZE NEW STUCCO FRONT SW 7015 REPOSE GRAY RECESSED METAL LOUVER IN DARK BRONZE NEW STUCCO FRONT SW 9170 ACIER EXISTING REAR ELEV. SCALE: 3/16" = 1'-0" 1 A.2.3 NEW REAR ELEV. SCALE: 3/16" = 1'-0" 2 A.2.3 A.2.3EXISTING REAR PHOTOS n ' J 0 ' € - ±------- - -----------------------------------------~~?,=- ------------------------------------------------------------------- #$$±a#ff" # E---- .Ke#f ,he, 'ate#ta~ 0 Page 25 of 68 A R CH ITECT S A R CH ITECT S parkerdesigngrouparchitects 843 785 5171 POST OFFICE BOX 5010 HILTON HEAD ISLAND SC 29938 A RENOVATION FOR : REVISIONS DATE OF ISSUE: TP SHEET OF SHEETS TP SCALE DRAWN BY CHECKED BY JOB NO. 2/25/26 HILTON HEAD , S.C. SERG GROUP THE ATRIUM BUILDING These documents & designs are the property of Parker Design Group | Architects & are not to be used or reproduced there of or for designs, working drawings, or construction of buildingswithout the written authorization from the copy write owner PDG|Architects 2024 copyright C 10'-0" ACCOYA WOOD RAINSCREEN NEW TRIM SW 9170 ACIER NEW STUCCO FRONT SW 7015 REPOSE GRAY NEW STOREFRONT WINDOWS - DARK BRONZE NEW PAC CLAD ROOFING- DARK BRONZE EXISTING RIGHT SIDE ELEV. SCALE: 3/16" = 1'-0" 1 A.2.4 NEW RIGHT SIDE ELEV. SCALE: 3/16" = 1'-0" 2 A.2.4 A.2.4EXISTING RIGHT SIDE ELEVATION PHOTOS n rt, I I I I II I I I I I II I I I I I II I I I I ,I ------------------- ------------------------------------------------------------------------------------ __--- t-----~ -----------· ~HAi-- 0 Page 26 of 68 A R CH ITECT S A R CH ITECT S parkerdesigngrouparchitects 843 785 5171 POST OFFICE BOX 5010 HILTON HEAD ISLAND SC 29938 A RENOVATION FOR : REVISIONS DATE OF ISSUE: TP SHEET OF SHEETS TP SCALE DRAWN BY CHECKED BY JOB NO. 2/25/26 HILTON HEAD , S.C. SERG GROUP THE ATRIUM BUILDING These documents & designs are the property of Parker Design Group | Architects & are not to be used or reproduced there of or for designs, working drawings, or construction of buildingswithout the written authorization from the copy write owner PDG|Architects 2024 copyright C 10'-0" EVENT SPACE #3CATERING KITCHEN KITCHEN RETAIL COOLER LINEAR ACCOUSTICAL PANELS LINEAR ACCOUSTICAL PANELS 11'-0" TASTING/ MEETING EVENT SPACE #3 KITCHEN NEW (2) STORY ENTRANCEWOMENS ACCOYA WOOD CEILING BUILDING SECTION SCALE: 3/16" = 1'-0" 2 A.2.5 A.2.5 BUILDING SECTION SCALE: 3/16" = 1'-0" 1 A.2.5 Page 27 of 68 A R CH ITECT S A R CH ITECT S parkerdesigngrouparchitects 843 785 5171 POST OFFICE BOX 5010 HILTON HEAD ISLAND SC 29938 A RENOVATION FOR : REVISIONS DATE OF ISSUE: TP SHEET OF SHEETS TP SCALE DRAWN BY CHECKED BY JOB NO. 2/25/26 HILTON HEAD , S.C. SERG GROUP THE ATRIUM BUILDING These documents & designs are the property of Parker Design Group | Architects & are not to be used or reproduced there of or for designs, working drawings, or construction of buildingswithout the written authorization from the copy write owner PDG|Architects 2024 copyright C RETAILTASTING/ MEETINGEVENT SPACE #1 WALK IN COOLER EVENT SPACE #3EVENT SPACE #2 LINEAR ACCOUSTICAL PANELS LINEAR ACCOUSTICAL PANELS 10'-0" 11'-0" 12'-0" RETAIL EVENT SPACE #1 ENTRY EVENT SPACE #2 SIGNAGE ACCENT TILE / WATERFALL WALL LINEAR ACCOUSTICAL PANELS LINEAR ACCOUSTICAL PANELS LINEAR ACCOUSTICAL PANELS WOOD ACCENT PANELS TO MATCH CEILING SIGNAGE BUILDING SECTION SCALE: 3/16" = 1'-0" 1 A.2.6 A.2.6BUILDING SECTION SCALE: 3/16" = 1'-0" 2 A.2.6 Page 28 of 68 A R CH ITECT S A R CH ITECT S parkerdesigngrouparchitects 843 785 5171 POST OFFICE BOX 5010 HILTON HEAD ISLAND SC 29938 A RENOVATION FOR : REVISIONS DATE OF ISSUE: TP SHEET OF SHEETS TP SCALE DRAWN BY CHECKED BY JOB NO. 2/25/26 HILTON HEAD , S.C. SERG GROUP THE ATRIUM BUILDING These documents & designs are the property of Parker Design Group | Architects & are not to be used or reproduced there of or for designs, working drawings, or construction of buildingswithout the written authorization from the copy write owner PDG|Architects 2024 copyright C 5/8" SHEETROCK ROOFING SYSTEM TO RUN UP WALL ON TYP. SHEATHING TYP. TPO ROOFING ON TYP. COVER BOARDS SEE SPECIFICATIONS CANT STRIP, TYP. 2x6 STUDS- SPACING AND ATTACHMENT AS PERS STRUCTURAL ALUMINUM CAP W/ EXPANSION JOINTS AS REQUIRED- SEE SPEC. EXISTING SIP PANEL REPAIR AND REPLACE AS REQUIRED EXISTING ROOF STRUCTURE PAINT WHITE 7/8" STUCCO ON WIRE MESH ON 15# FELT ON TYVEC DRAINAGE WRAP 1/2" PLYWOOD SHEATHING AS PER STRUCTURAL- TR. PLYWOOD FOR FIRST 4'-0" OFF SLAB 5/8" SHEETROCK FURRING STRIPS TO ALLOW FOR CONDUIT FURRING STRIPS TO ALLOW FOR CONDUIT EXISTING FLOOR SYSTEM AND STEEL JOISTS ARMSTRONG SOUNDSCAPES BLADES- SEE RCP PAINT EXPOSED CEILING WHITE ARMSTRONG SOUNDSCAPES BLADES- SEE RCP EXISTING SIP PANEL REPAIR AND REPLACE AS REQUIRED 5/8" SHEETROCK ROOFING SYSTEM TO RUN UP WALL ON TYP. SHEATHING TYP. TPO ROOFING ON TYP. COVER BOARDS SEE SPECIFICATIONS CANT STRIP, TYP. ALUMINUM CAP W/ EXPANSION JOINTS AS REQUIRED- SEE SPEC. STRUCK JOINT 1X4 & 1X8 ACCOYA HORIZ. NICKLE SPACED SIDING ON FURRING STRIPS INSTALLED AS PER MANUF. RECOMMENDATIONS 3X3 ACCOYA DRIP FURRING STRIPS TO ALLOW FOR CONDUIT 2x6 STUDS- SPACING AND ATTACHMENT AS PERS STRUCTURAL 7/8" STUCCO ON WIRE MESH ON 15# FELT ON TYVEC DRAINAGE WRAP 1/2" PLYWOOD SHEATHING AS PER STRUCTURAL- TR. PLYWOOD FOR FIRST 4'-0" OFF SLAB TYP. STOREFRONT- SEE WINDOW AND DOOR SCHEDULES EXISTING FLOOR SYSTEM AND STEEL JOISTS EXISTING SIP PANEL REPAIR AND REPLACE AS REQUIRED EXISTING ROOF STRUCTURE PAINT WHITE ARMSTRONG SOUNDSCAPES BLADES- SEE RCP EXISTING SIP PANEL REPAIR AND REPLACE AS REQUIRED 2'-7" 11" 2'-0" CANT CURB BEYOND WEEP SCREED RUN TPO UP WALL BEHIND WRB TPO ROOFING COVER BOARD (MIN. 4" THK, R-23.6) CONCRETE ROOF DECK - SEE STRUCTURAL PODIUM FLOOR PEDESTAL STONE PAVERS ALUMINUM CAP W/ EXPANSION JOINTS AS REQUIRED- SEE SPEC. ALUMINUM POSTS AND RAILS WITH STAINLESS STEEL CABLES 7/8" STUCCO ON WIRE MESH ON 15# FELT ON TYVEC DRAINAGE WRAP 2x6 STUDS- SPACING AND ATTACHMENT AS PERS STRUCTURAL 7/8" STUCCO ON WIRE MESH ON 15# FELT ON TYVEC DRAINAGE WRAP 1/2" PLYWOOD SHEATHING AS PER STRUCTURAL- TR. PLYWOOD FOR FIRST 4'-0" OFF SLAB RECESSED LIGHT SEE RCP 5/8" SHEETROCK EXISTING SIP PANEL REPAIR AND REPLACE AS REQUIRED FURRING STRIPS TO ALLOW FOR CONDUIT A.3.1278 SIDE WALL SECTION SCALE: 1" = 1'-0" 1 A.3.1SCALE: 1" = 1'-0" 2 A.3.1 278 SIDE WALL SECTION SCALE: 1" = 1'-0" 3 A.3.1 278 SIDE WALL SECTION Page 29 of 68 A R CH ITECT S A R CH ITECT S parkerdesigngrouparchitects 843 785 5171 POST OFFICE BOX 5010 HILTON HEAD ISLAND SC 29938 A RENOVATION FOR : REVISIONS DATE OF ISSUE: TP SHEET OF SHEETS TP SCALE DRAWN BY CHECKED BY JOB NO. 2/25/26 HILTON HEAD , S.C. SERG GROUP THE ATRIUM BUILDING These documents & designs are the property of Parker Design Group | Architects & are not to be used or reproduced there of or for designs, working drawings, or construction of buildingswithout the written authorization from the copy write owner PDG|Architects 2024 copyright C 10" 1'-0" 5'-8" 1X4 & 1X8 ACCOYA HORIZ. NICKLE SPACED SIDING BEYOND 1/2" AZEK WRAPPED HEADER ON TYVEK DRAINAGE WRAP 1" AZEK SILL ON RUBBER MEMBRANE OVER STO GUARD WATERPROOF AIR BARRIER 1/2" AZEK SHEET ON TYVEK DRAINAGE WRAP STRUCK CONTROL JOINT ALUMINUM CAP W/ EXPANSION JOINTS AS REQUIRED- SEE SPEC. 1X6 ACCOYA WOOD ON BLOCKING TO ALLOW FOR EXISTING SPRINKLER SYSTEM TO BE RUN UNDER 5/8" SHEETROCK 2x6 STUDS- SPACING AND ATTACHMENT AS PERS STRUCTURAL 7/8" STUCCO ON WIRE MESH ON 15# FELT ON TYVEC DRAINAGE WRAP 1/2" PLYWOOD SHEATHING AS PER STRUCTURAL- TR. PLYWOOD FOR FIRST 4'-0" OFF SLAB 1/2" PLYWOOD SHEATHING AS PER STRUCTURAL- TR. PLYWOOD FOR FIRST 4'-0" OFF SLAB R-13 OPEN CELL SPRAY FOAM INSULATION STRUCK CONTROL JOINT 7/8" STUCCO ON WIRE MESH ON 15# FELT ON TYVEC DRAINAGE WRAP 1/2" PLYWOOD SHEATHING AS PER STRUCTURAL- TR. PLYWOOD FOR FIRST 4'-0" OFF SLAB AIR FOIL ALUM. LOUVERS ATTACHED TO STOREFRONT AS PER MANUF. INSTRUCTIONS STRUCK CONTROL JOINT 1X4 & 1X8 ACCOYA HORIZ. NICKLE SPACED SIDING ON 2x4 FURRING STRIPS INSTALLED AS PER MANUF. RECOMMENDATIONS ON TYVEK DRAINAGE WRAP 1/2" AZEK WRAPPED HEADER ON TYVEK DRAINAGE WRAP 1" AZEK SILL ON RUBBER MEMBRANE OVER TYVEK DRAINAGE WRAP ALUMINUM CAP W/ EXPANSION JOINTS AS REQUIRED- SEE SPEC. 1X6 ACCOYA WOOD ON BLOCKING TO ALLOW FOR EXISTING SPRINKLER SYSTEM TO BE RUN UNDER 2x6 STUDS- SPACING AND ATTACHMENT AS PERS STRUCTURAL 7/8" STUCCO ON WIRE MESH ON 15# FELT ON TYVEC DRAINAGE WRAP 1/2" PLYWOOD SHEATHING AS PER STRUCTURAL- TR. PLYWOOD FOR FIRST 4'-0" OFF SLAB STRUCK CONTROL JOINT 7/8" STUCCO ON WIRE MESH ON 15# FELT ON TYVEC DRAINAGE WRAP 1/2" PLYWOOD SHEATHING AS PER STRUCTURAL- TR. PLYWOOD FOR FIRST 4'-0" OFF SLAB 5/8" SHEETROCK 1/2" PLYWOOD SHEATHING AS PER STRUCTURAL- TR. PLYWOOD FOR FIRST 4'-0" OFF SLAB R-13 OPEN CELL SPRAY FOAM INSULATION LED LINEAR LIGHT SEE REFLECTED CEILING PLAN AIR FOIL ALUM. LOUVERS ATTACHED TO STOREFRONT AS PER MANUF. INSTRUCTIONS ROOFING SYSTEM TO RUN UP WALL ON TYP. SHEATHING CANT STRIP, TYP. 2X WOOD FURRING STRIPS AS PER STRUCTURAL ALUMINUM CAP W/ EXPANSION JOINTS AS REQUIRED- SEE SPEC. STRUCK JOINT 7/8" STUCCO ON WIRE MESH ON 15# FELT ON TYVEC DRAINAGE WRAP 1/2" PLYWOOD SHEATHING AS PER STRUCTURAL- TR. PLYWOOD FOR FIRST 4'-0" OFF SLAB 7/8" STUCCO ON WIRE MESH ON 15# FELT ON TYVEC DRAINAGE WRAP EXISTING SIP PANEL REPAIR AND REPLACE AS REQUIRED 5/8" SHEETROCK FURRING STRIPS TO ALLOW FOR CONDUIT 5/8" SHEETROCK FURRING STRIPS TO ALLOW FOR CONDUIT EXISTING FLOOR SYSTEM AND STEEL JOISTS EXISTING SIP PANEL REPAIR AND REPLACE AS REQUIRED EXISTING ROOF STRUCTURE PAINT WHITE A.3.2278 SIDE WALL SECTION SCALE: 1" = 1'-0" 1 A.3.2SCALE: 1" = 1'-0" 2 A.3.2 278 SIDE WALL SECTION SCALE: 1" = 1'-0" 3 A.3.2 REAR WALL SECTION Page 30 of 68 A R CH ITECT S A R CH ITECT S parkerdesigngrouparchitects 843 785 5171 POST OFFICE BOX 5010 HILTON HEAD ISLAND SC 29938 A RENOVATION FOR : REVISIONS DATE OF ISSUE: TP SHEET OF SHEETS TP SCALE DRAWN BY CHECKED BY JOB NO. 2/25/26 HILTON HEAD , S.C. SERG GROUP THE ATRIUM BUILDING These documents & designs are the property of Parker Design Group | Architects & are not to be used or reproduced there of or for designs, working drawings, or construction of buildingswithout the written authorization from the copy write owner PDG|Architects 2024 copyright C 7" ROOFING SYSTEM TO RUN UP WALL ON TYP. SHEATHING TYP. TPO ROOFING ON TYP. COVER BOARDS SEE SPECIFICATIONS CANT STRIP, TYP. ALUMINUM CAP W/ EXPANSION JOINTS AS REQUIRED- SEE SPEC. EXISTING ROOF STRUCTURE STANDING SEAM METAL ROOFING ON TYPAR SURROUND SR UNDERLAYMENT - REPLACE ROOF SHEATHING AS REQUIRED EXISTING SLEEPERS TO HIDE EXISTING CONDIUT METAL DRIP TO MATCH ROOF PANELS PVC 1X8 ON CUT 1X PANELS ON EXISTING FRAMING EXISTING WOOD BEAMS PVC 1X WRAPPED COLUMNS OVER EXISTING WOOD COLUMNS EXISTING WOOD CEILINGS 2x6 STUDS- SPACING AND ATTACHMENT AS PERS STRUCTURAL 7/8" STUCCO ON WIRE MESH ON 15# FELT ON TYVEC DRAINAGE WRAP 1/2" PLYWOOD SHEATHING AS PER STRUCTURAL METAL FLASHING TO MATCH METAL ROOF 7/8" STUCCO ON WIRE MESH ON 15# FELT ON TYVEC DRAINAGE WRAP 5/8" SHEETROCK EXISTING SIP PANEL REPAIR AND REPLACE AS REQUIRED FURRING STRIPS TO ALLOW FOR CONDUIT EXISTING SIP PANEL REPAIR AND REPLACE AS REQUIRED 7" STANDING SEAM METAL ROOFING ON TYPAR SURROUND SR UNDERLAYMENT - REPLACE ROOF SHEATHING AS REQUIRED EXISTING SLEEPERS TO HIDE EXISTING CONDIUT METAL DRIP TO MATCH ROOF PANELS PVC 1X8 ON CUT 1X PANELS ON EXISTING FRAMING EXISTING WOOD BEAMS PVC 1X WRAPPED COLUMNS OVER EXISTING WOOD COLUMNS EXISTING WOOD CEILINGS METAL FLASHING TO MATCH METAL ROOF R-13 OPEN CELL SPRAY FOAM INSULATION ROOFING SYSTEM TO RUN UP WALL ON TYP. SHEATHING TYP. TPO ROOFING ON TYP. COVER BOARDS SEE SPECIFICATIONS CANT STRIP, TYP. ALUMINUM CAP W/ EXPANSION JOINTS AS REQUIRED- SEE SPEC. EXISTING ROOF STRUCTURE 2x6 STUDS- SPACING AND ATTACHMENT AS PERS STRUCTURAL 7/8" STUCCO ON WIRE MESH ON 15# FELT ON TYVEC DRAINAGE WRAP 1/2" PLYWOOD SHEATHING AS PER STRUCTURAL STRUCK JOINT 1X4 ACCOYA HORIZ. NICKLE SPACED SIDING ON FURRING STRIPS INSTALLED AS PER MANUF. RECOMMENDATIONS 3X3 ACCOYA DRIP TYP. STOREFRONT- SEE WINDOW AND DOOR SCHEDULES 5/8" SHEETROCK 7/8" STUCCO ON WIRE MESH ON 15# FELT ON TYVEC DRAINAGE WRAP 5/8" SHEETROCK EXISTING SIP PANEL REPAIR AND REPLACE AS REQUIRED FURRING STRIPS TO ALLOW FOR CONDUIT EXISTING SIP PANEL REPAIR AND REPLACE AS REQUIRED A.3.3PORCH SECTION SCALE: 1" = 1'-0" 1 A.3.3 PORCH SECTION SCALE: 1" = 1'-0" 2 A.3.3 Page 31 of 68 A R CH ITECT S A R CH ITECT S parkerdesigngrouparchitects 843 785 5171 POST OFFICE BOX 5010 HILTON HEAD ISLAND SC 29938 A RENOVATION FOR : REVISIONS DATE OF ISSUE: TP SHEET OF SHEETS TP SCALE DRAWN BY CHECKED BY JOB NO. 2/25/26 HILTON HEAD , S.C. SERG GROUP THE ATRIUM BUILDING These documents & designs are the property of Parker Design Group | Architects & are not to be used or reproduced there of or for designs, working drawings, or construction of buildingswithout the written authorization from the copy write owner PDG|Architects 2024 copyright C 5 1/2" 2x6 STUDS- SPACING AND ATTACHMENT AS PERS STRUCTURAL 7/8" STUCCO ON WIRE MESH ON 15# FELT ON TYVEC DRAINAGE WRAP 1/2" PLYWOOD SHEATHING AS PER STRUCTURAL STRUCK JOINT 1/2" AZEK WRAPPED ROOFING SYSTEM TO RUN UP WALL ON TYP. SHEATHING TYP. TPO ROOFING ON TYP. COVER BOARDS SEE SPECIFICATIONS CANT STRIP, TYP. ALUMINUM CAP W/ EXPANSION JOINTS AS REQUIRED- SEE SPEC. TR. 1/2" PLYWOOD SHEATHING AS PER STRUCTURAL PODIUM FLOOR PEDESTAL STONE PAVERS ROOFING SYSTEM TO RUN UNDER SILL FOLDING DOOR SYSTEM- SEE DOOR SCHEDULE TPO ROOFING COVER BOARD (MIN. 4" THK, R-23.6) CONCRETE ROOF DECK - SEE STRUCTURAL 1X4 & 1X8 ACCOYA HORIZ. NICKLE SPACED SIDING ON FURRING STRIPS INSTALLED AS PER MANUF. RECOMMENDATIONS 2x6 STUDS- SPACING AND ATTACHMENT AS PERS STRUCTURAL 1/2" PLYWOOD SHEATHING AS PER STRUCTURAL-TR. PLYWOOD FOR FIRST 4'-0" 7/8" STUCCO ON WIRE MESH ON 15# FELT ON TYVEC DRAINAGE WRAP 1/2" PLYWOOD SHEATHING AS PER STRUCTURAL STRUCK JOINT 1/2" AZEK WRAPPED LED LINEAR LIGHT SEE REFLECTED CEILING PLAN PODIUM FLOOR PEDESTAL STONE PAVERS ROOFING SYSTEM TO RUN UP WALL ON TYP. SHEATHING TYP. TPO ROOFING ON TYP. COVER BOARDS SEE SPECIFICATIONS CANT STRIP, TYP. ALUMINUM CAP W/ EXPANSION JOINTS AS REQUIRED- SEE SPEC. ROOFING SYSTEM TO RUN 2'-0" UP THE WALL UNDER VAPOR BARRIER TPO ROOFING COVER BOARD (MIN. 4" THK, R-23.6) CONCRETE ROOF DECK - SEE STRUCTURAL EXISTING SIP PANEL REPAIR AND REPLACE AS REQUIRED 2x6 STUDS- SPACING AND ATTACHMENT AS PERS STRUCTURAL 7/8" STUCCO ON WIRE MESH ON 15# FELT ON TYVEC DRAINAGE WRAP 1/2" PLYWOOD SHEATHING AS PER STRUCTURAL ROOFING SYSTEM TO RUN UP WALL ON TYP. SHEATHING TYP. TPO ROOFING ON TYP. COVER BOARDS SEE SPECIFICATIONS CANT STRIP, TYP. ALUMINUM CAP W/ EXPANSION JOINTS AS REQUIRED- SEE SPEC. TPO ROOFING COVER BOARD (MIN. 4" THK, R-23.6) CONCRETE ROOF DECK - SEE STRUCTURAL 1/2" PLYWOOD SHEATHING AS PER STRUCTURAL-TR. PLYWOOD FOR FIRST 4'-0" PODIUM FLOOR PEDESTAL STONE PAVERS ROOFING SYSTEM TO RUN 2'-0" UP THE WALL UNDER VAPOR BARRIER EXISTING SIP PANEL REPAIR AND REPLACE AS REQUIRED 7'-0" 1 1/2" TR. 6 x 6 POSTS SET IN CONC. FOOTERS SLOPED BROOM FINISH CONC. @ 1/4"/1'-0" 5/4 x 8 ACCOYA BOARDS 2'-0" 3 1/2" METAL DRIP CUT 2X8'S @ 16" O.C. PVC 1X6 SOFFIT BOARD WITH 1X2 BATTENS AT WALL AND PERPENDICULAR @ 8'-0" O.C. TR. 4X10 BEAM ON METAL SADDLE NEW 4" METAL POST WELDED TO EXISTING STAIR STRUCTURE- SEE STRUCTURAL STANDING SEAM METAL ROOFING ON TYPAR SURROUND SR UNDERLAYMENT ON 5/8" PLYWOOD EXISTING METAL RAILING REPAIR AND REPAINT AS REQUIRED A.3.4OUTDOOR DECK SECTION SCALE: 1" = 1'-0" 1 A.3.4 OUTDOOR DECK SECTION SCALE: 1" = 1'-0" 2 A.3.4 OUTDOOR DECK SECTION SCALE: 1" = 1'-0" 3 A.3.4 REAR STAIR ROOF SCALE: 1" = 1'-0" 4 A.3.4 SERVICE YARD DETAIL SCALE: 1" = 1'-0" 5 A.3.4 Page 32 of 68 Page 33 of 68 1 DDEESSIIGGNN TTEEAAMM//DDRRBB CCOOMMMMEENNTT SSHHEEEETT TThhee ccoommmmeennttss bbeellooww aarree ssttaaffff rreeccoommmmeennddaattiioonnss ttoo tthhee DDeessiiggnn RReevviieeww BBooaarrdd ((DDRRBB)) aanndd ddoo NNOOTT ccoonnssttiittuuttee DDRRBB aapppprroovvaall oorr ddeenniiaall.. PROJECT NAME: 840 William Hilton Parkway – The Atrium Building DRB-000212-2026 DATE: 03/11/2026 CATEGORY: Final RECOMMENDATION: Approval Approval with Conditions Denial APPLICATION MATERIAL DRB REQUIREMENTS Complies Yes No Not Applicable Comments or Conditions Demolition Plan if needed Existing Conditions match As-Built Dimensioned Details and of Sections Detail Illustrating Connection to Existing Structure New Building Details Match Existing Building Details ARCHITECTURAL DESIGN DESIGN GUIDE/LMO CRITERIA Complies Yes No Not Applicable Comments or Conditions Structure is designed to be appropriate to the neighborhood Promotes pedestrian scale and circulation Design is unobtrusive and set into the natural environment Utilizes natural materials and colors Avoids distinctive vernacular styles Design is appropriate for its use All facades shall have equal design characteristics Page 34 of 68 2 Avoids monotonous planes or unrelieved repetition Has a strong roof form with enough variety to provide visual interest Overhangs are sufficient for the façade height. Forms and details are sufficient to reduce the mass of the structure Human scale is achieved by the use of proper proportions and architectural elements Utilizes a variety of materials, textures and colors Incorporates wood or wood simulating materials Windows are in proportion to the facade Details are clean, simple and appropriate while avoiding excessive ornamentation Utilities and equipment are concealed from view Decorative lighting is limited and low wattage and adds to the visual character Accessory elements are designed to coordinate with the primary structure LANDSCAPE DESIGN DESIGN GUIDE/LMO CRITERIA Complies Yes No Not Applicable Comments or Conditions Treats the Landscape as a major element of the project Provides Landscaping of a scope and size that is in proportion to the scale of the development Landscape is designed so that it may be maintained in its natural shape and size Preserves a variety of existing native trees and shrubs Provides for a harmonious setting for the site’s structures, parking areas or other construction Location of existing trees and new trees provides street buffers, mitigation for parking lots, and an architectural complement that visually mitigates between parking lots and building(s) Shrubs are selected to complement the natural setting, provide visual interest and screen less-desirable elements of the project A variety of species is selected for texture and color Provides overall order and continuity of the Landscape plan Page 35 of 68 3 Native plants or plants that have historically been prevalent on the Island are utilized A variety of sizes is selected to create a “layered” appearance for visual interest and a sense of depth The location of existing mature trees is taken into account in placement of shrubs so as not to damage tree roots Proper spacing and location for plants to reach their mature size and natural shape while avoiding excessive or unnatural pruning Proposed groundcovers are evergreen species with low maintenance needs Large, grassed lawn areas encompassing a major portion of the site are avoided The adjacent development is taken into account in determining the most appropriate buffer so as not to depart too dramatically from the neighborhood Ornamentals and Annuals are limited to entrances and other focal points NATURAL RESOURCE PROTECTION DESIGN GUIDE/LMO CRITERIA Complies Yes No Not Applicable Comments or Conditions An effort has been made to preserve existing trees and under story plants Supplemental and replacement trees meet LMO requirements for size, species and number Wetlands if present are avoided and the required buffers are maintained Sand dunes if present are not disturbed COMMENTS & CONDITIONS Staff recommend approval of the Final submittal for 840 William Hilton Parkway, The Atrium Building with the following conditions: 1. The outdoor areas associated with the upper-level spaces shall not be used for Outdoor Commercial Recreation, other than water Parks, including but not limited to events or assembly spaces. The applicant shall provide a building section and plan notation clearly identifying all spaces and specify their intended use for verification at final review. 2. Any additional information as required by the Board. Page 36 of 68 Page 37 of 68 TownofHiltonHeadIsland CommunityDevelopmentDepartment lTownCenterCourt HiltonHeadIsland,SC29928 Phone:843-341-4757Fax:843-341-2087 hiltonheadislandsc.goy FOROFFICIALUSEONLY DateReceived: Acceptedby. pp.#:DRB: APPLICATIONPACKETFOR MAJORCORRIDORREVIEW(MAJORDPR) Applicant Name:w(rtJwite>(€r. Phone:4375774fl MailingAddress:Poox303¢ (3/Pp»N!,s-4«10 Email:Ju2wdkrp.cow PropertyOwner Name:fouNBANl. Phone: 8,$$pie»e-vsB. Sou,vA2343 Email: TownBusinessLicense#(ifapplicable): ProjectInformation ParcelNumber(PIN)RS6oTl@o@f3o0oo ProjectName:[64HPR0p€FT(esblq ProjectAddress:8GzuHP ZoningDistrict[OverlayDistrict(s):COR ProjectDescription:3ON{:w-_CANO(4nooiF 46(wToa€Apo€'fAfkrAr31€oPpw-+4,611 ei-ox«ge(ow«ec-)_pe,4pcr@fftot6sq.wk ProjectCategory.YfWa{tcus! []conceptApproval-ProposedDevelopment{Alteration/Addition DFinalApproval-ProposedDevelopment[]sign Date:2/23/26 @we@Es[@ ApplicantSignature: Arethererecordedprivatecovenantsand/orrestrictionsthatarecontraryto,conflictwith,orprohibitthe proposedrequest?Ifso,acopyoftheprivatecovenantsand/orrestrictionsmustbesubmittedwiththis application[YvEsorSo Disclaimer:TheTownofHiltonHeadIslandassumesnolegalorfinancialliabilitytotheapplicantoranythirdpartywhatsoever byapprovingtheplansassociatedwiththispermit. IherebyacknowledgebymysignaturebelowthattheforegoingapplicationiscompleteandaccurateandthatIamtheownerof thesubjectproperty.Asapplicable,Iauthorizethesubjectpropertytobepostedandinspected. PropertyOwnerSignature: TownofHiltonHeadIslandMajorCorridorReviewApplicationUpdated11/1112025 Page 38 of 68 TownofHiltonHeadIsland MAJORCORRIDORREVIEWAPPLICATION ProcessNarrative ThefollowingProcessNarrativeisintendedtoprovideApplicantswithanunderstandingoftherespective applicationprocess,proceduresandLandManagementOrdinance{LMO)requirementsforobtaining applicationapprovalintheTownofHiltonHeadIsland.Whileintendedtoexplaintheprocess,itisnot intendedtorepeal,eliminateorotherwiselimitanyrequirements,regulationsorprovisionsoftheTownof HiltonHeadIsland'sLandManagementOrdinance.TheTownofHiltonHeadIsland'sMissionandVision StatementshelpnavigatestafftoensurethatthegoalsoutlinedbyTownCouncilarebeingmet.Aseach projectisbeingreviewed,TownstaffwillusetheMissionStatement,VisionStatement,TheCovenantfor HiltonHeadIslandandthecurrentStrategicPlantoguidetheirreview.Compliancewiththeseprocedureswill minimizedelaysandassureexpeditiousapplicationreview. Step1:ApplicationSubmittalApplicant Applicant AnapplicationforMajorCorridorConceptualReviewmaybesubmittedbythelandowner(s)ofthelandonwhich developmentisproposedorapersonauthorizedinwritingtosubmittheapplicationonbehalfofthelandowner(s). Step2:StaffReviewandActionI Staff Onreceivinganapplication,theOfficialshallreviewandmakeafinaldecisionontheapplicationinaccordancewith Sec.16-2-102.D.TheOfficial'sdecisionshallbebasedonthestandardsinSec.16-2-103.1.5,CorridorReview(Minor andMajor)Standards,andshallbeoneofthefollowing: •Approvetheapplication; •Approvetheapplicationsubjecttoconditionsofapproval;or •Denytheapplication. Step3:NoticeofDecisionStaff TheOfficialshallprovidewrittennoticeofthefinaldecisionontheapplicationwithinfivebusinessdaysafterthe finaldecision.AcopyofthedecisionshallalsobemadeavailabletothepublicatTownHallduringnormalbusiness hours. Step4:ApplicationSubmittalforFinalReview AnapplicationforMajorCorridorFinalReviewmaybesubmittedbythelandowner(s)ofthelandonwhich developmentisproposedorapersonauthorizedinwritingtosubmittheapplicationonbehalfofthelandowner(s). Step5:StaffreviewandActionI Staff Onreceivinganapplication,theOfficialshallreviewtheapplicationandprepareastaffreportwitha recommendationforactionontheapplicationinaccordancewithSec.16-2-102.D.TheOfficial'srecommendation shallbebasedonthestandardsinSec.16-2-103.1.5,CorridorReview(MinorandMajor)Standards. Step6:DesignReviewBoardConsiderationIDesignReviewBoard TheDesignReviewBoardshallreviewtheapplication,staffreport,andanynoticeofactionsubmittedbyaprivate architecturalreviewboardatapublicmeetingandmakeafinaldecisionontheapplicationinaccordancewithSec. 16-2-102.G.TheOfficial'sdecisionshallbebasedonthestandardsinSec.16-2-103.1.5,CorridorReview(Minorand Major)Standards,andshallbeoneofthefollowing: •Approvetheapplication; •Approvetheapplicationsubjecttoconditionsofapproval;or •Denytheapplication. Step7:NoticeofDecisionStaff TheOfficialshallprovidewrittennoticeofthefinaldecisionontheapplication.Acopyofthedecisionshallalsobe madeavailabletothepublicatTownHallduringnormalbusinesshours. TownofHiltonHeadIslandMajorCorridorReviewApplicationUpdatedI1/1112025 Page 39 of 68 TownofHiltonHeadIsland MAJORCORRIDORREVIEWAPPLICATION MinimumRequirementsforSubmittal DAnApplicationReviewFeeasdeterminedbytheTownofHiltonHeadIslandMasterFeeSchedule.Checks PayabletoTownofHiltonHeadIsland.1..p. AAcompletedAffidavitofOwnership DPrivatecovenantand/orrestrictions,ifapplicable. InAddition: ForConceptApproval-ProposedDevelopment []Asurvey(1"=30'minimumscale)ofpropertylines,existingtopographyandthelocationoftreesmeeting thetreeprotectionregulationsofSec.16-6-104,TreeProtection,andifapplicable,locationofborderingstreets, marshesandbeaches.SitePlan(1"=30'minimumscale)showinglocationofexistingdevelopment. DAsiteanalysisstudytoincludespecimentrees,access,significanttopography,wetlands,buffers,setbacks, views,orientationandothersitefeaturesthatmayinfluencedesign. DAdraftwrittennarrativedescribingthedesignintentoftheproject,itsgoalsandobjectivesandhowitreflects thesiteanalysisresults. DContextphotographsofneighboringusesandarchitecturalstyles. DConceptualsiteplan(toscale)showingproposedlocationofnewstructures,parkingareasandlandscaping. DConceptualsketchesofprimaryexteriorelevationsshowingarchitecturalcharacterofthe proposeddevelopment,materials,colors,shadowlinesandlandscaping. ForConceptApproval-ProposedDevelopment XAfinalwrittennarrativedescribinghowtheprojectconformswiththeconceptualapprovalanddesignreview guidelinesintheDesignGuide. _)i{._FinalsitedevelopmentplanmeetingtherequirementsofD·6.F,SiteDevelopmentPlan. ')(FinalsitelightingandlandscapingplansmeetingtherequirementsofD-6.1.SiteLightingPlanandD-6.H. LandscapePlan. XKsfloorplansandelevationdrawings(1/8"=1'-0"minimumscale)showingexteriorbuildingmaterialsand colorswitharchitecturalsectionsanddetailstoadequatelydescribetheproject. Xcolorboard(11"17"maximum)containingactualcolorsamplesofallexteriorfinishes,keyedtothe elevations,andindicatingthemanufacturer'snameandcolordesignation. DAnyadditionalinformationrequestedbytheDesignReviewBoardatthetimeofconceptapproval,suchasscale modelorcolorrenderings,thattheBoardfindsnecessaryinordertoactonafinalapplication. ForConceptApproval-ProposedDevelopment )!(Allofthematerialsrequiredforafinalapprovalofaproposeddevelopment(seeprevioussection). }Asurvey(1"=30'minimumscale)ofpropertylines,existingtopographyandthelocationoftreesmeeting thetreeprotectionregulationsofSec.16-6-104,TreeProtection,andifapplicable,locationofborderingstreets, marshesandbeaches. )('Photographsofexistingstructure(s). TownofHiltonHeadIslandMajorCorridorReviewApplicationUpdated11/11/2025 Page 40 of 68 ForConceptApproval-ProposedDevelopment []Accuratecolorrenderingsofsignshowingdimensions,typeoflettering,andactualcolorsamples. DForfreestandingsigns: oSiteplan(1"=30'minimumscale)showinglocationofthesigninrelationbuildings,parking,existingsigns, andpropertylines. oProposelandscapingplan. DForwallsigns: oPhotographordrawingofthebuildingdepictingtheproposedlocationofthesign. oLocation,fixturetype,andwattageofanyproposedlighting. I ApplicantSignature:.A/1...1,'r 9 TownofHiltonHeadIslandMajorCorridorReviewApplication one z/a[:@ Updated11/11/2025 Page 41 of 68 862 William Hilton Parkway 550-011-000-0153-000 Exterior renovations to an existing office building. Judd Carstens, Witmer Jones Keefer, Ltd. AFFIDAVIT OF OWNERSHIP AND RESPONSIBILITIES AND HOLD HARMLESS PERMISSION TO ENTER PROPERTY The undersigned being duly sworn and upon oath states as follows: 1. I am the current owner of the property which is the subject ofthis application. 2. I hereby authorize to act as my agent for this application only.3. All statements contained in this application have been prepared by me or my agents and are true and correct to the best of my knowledge. 4. The application is being submitted with my knowledge and consent. 5. Owner grants the Town, its employees, agents, engineers, contractors or other representatives the right to enter uponOwner's real property, located at (address), (parcel ID) for the purpose of application review, for the limited time necessary to complete that purpose. Description of Work: 6. Owner agrees to hold the Town harmless for any loss or damage to persons or property occurring on the private property during the Town's entry upon the property, unless the loss or damage is the result of the sole negligence of the Town. 7. I acknowledge that the Town of Hilton Head Island Municipal Code requires that all construction in a Special Flood Hazard Zone be constructed in accordance with the following provisions that: a. any enclosed area below the base flood elevation will be used solely for parking of vehicles, limited storage or access to the building. This space will never be used for human habitation without first becoming fully compliant with the Town's Flood Damage Controls Ordinance in effect at the time of conversion. b. all interior walls, ceilings and floors below the base flood elevation will be constructed of flood resistant materials. c. all mechanical, electrical and plumbing devices will be installed above base flood elevation. d. walls of the enclosed area below base flood elevation will be equipped with at least two openings which allow automatic entry and exit of flood water. Openings will be on two different walls with at least one square inch of free area for every square foot of enclosed space and have the bottom of openings no more than a foot above grade. e. the structure may be subject to increased premium rates for flood insurance from the National Flood Insurance Program. 8. I understand that failure to abide by Town permits, any conditions, and all codes adopted by the Town of Hilton Head Island deems me subject to enforcement action and/or fines. The foregoing instrument was acknowledged before me JesL.,Hhqis personally known to me or has producedas identification and who did not take an oath. 2 g9'iQck>her.An.2o a4 My Commission expires: 2 - 2 ¥-202ePlease affix seal or stamp. WITNESS my hand a _h\2a9d/+ii.lGiie siesiire Page 42 of 68 Page 43 of 68 23 Promenade St. Ste 201 Bluffton, SC 29910 Tel: 843.757.7411 DRB ALTERATION Narrative Beach Properties Building 862 Wm. Hilton Parkway, Hilton Head Island, SC 29928 This project proposes to amend a previously approved DRB plan set for the Beach Properties building at 862 William Hilton Parkway. Associated with this request is providing a small canopy and exterior locker system at the side staff building entry and providing a dumpster enclosure at rear of property (built to match existing propane storage enclosure and HVAC enclosure). The work associated with this project is isolated to the southwestern building façade and rear parking bay. The existing building will be modified to include a small canopy at the staff entry. Adjacent to this entry door will be an exterior locker system - a common element in the short-term rental management operations. Both elements will be dark bronze color to match window treatments on the building. No existing sidewalks need to be expanded or modified, nor foundation plant material removed. The proposed landscape will screen the proposed dumpster enclosure from rear access road. This enclosure will match the existing propane storage enclosure and HVAC enclosure nearby. All plant material will be native material aimed at longevity and maintainability. In closing, as with the original DRB request, this amendment for 862 William Hilton Parkway will support an on-island business whose goal to showcase and welcome visitors and families vacationing on Hilton Head. Sincerely, Judd Carstens Attachment «srles;" glandscape architecture 0land planning Page 44 of 68 Page 45 of 68 DRB ALTERATIONSUBMITTAL,NOT FORCONSTRUCTION DRAWING NUMBERDRAWING TITLE DESIGN CONCEPTS, DRAWING, SHEETS,LOGOS, SPECIFICATIONS, DETAILS,WRITTEN MATERIAL SHALL NOT BE USEDOR REPRODUCED IN WHOLE OR IN PARTIN ANY FORM WITHOUT PRIOR WRITTENCONSENT OF WJK LTD.© 2026 WJK LTD.THIS SHEET TO SCALE AT: 30"X42" DATE:PROJECT NO.:DRAWN BY:CHECKED BY:FEB 25, 202624095.01JCXX REVISIONS:SITE DEVELOPMENT PLANSFOR862 WILLIAM HILTON PARKWAYTOWN OF HILTON HEAD ISLAND, SOUTH CAROLINABEACH PROPERTIES BUILDING EXISTING CONDITIONS-PHOTOS-L00 BUILDING FACADE BUILDING FACADE - DOOR AND LOCKER PAD BUILDING FACADE - DOOR AND LOCKER PAD • ' ~~ 11: N. ec5 s%% a-o~00 ~.:£ v-z ~obo03 = 34 ±iO & ge?'Os ?3 ,Gs¢8 s:=-♦"al,!<i eI$"r, & c>.,s$3 ?4zoil $- , ~ % o ~Calv 2,i~gs %1u«i ± di n :~¢0 ¥ 5 £ cl: 03 v -­, . - - -- 4 • Page 46 of 68 3 A201 2 A201 4 A201 1 A201 2 A301 1 A301 3 A302 1 2 3 4 5 3 6 7 16 4 12 11 5 A302 3 11'-4" 11'-4" 9" 40'-3" 10'-0" CL DS DS DS DS DS DS DS DS DS DS DS DS 5 2 A303 B A 10 11 11 11 11 9 20'-0" 20'-3" CENTER WALL ON EXISTING COLUMN NEW POST 100 102 103 104 5'-2" 5'-2" B1 B1 A1 A1 8'-0" 11'-3" 10'-0" 10'-0" 4'-6" 10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 1'-2" 4 A303 2.3 3 4 5 A B B C 7'-5" 6 A303 TYP. 10 A303 10 A303 SIM. OH 4 A302 2 A302 1 A302 TYP TYP 1 AS001 13 13 F.O. STUD CL OF STUD TYP. TYP. G 2 2.7 F 10'-0" 10'-0" 10'-0" 10'-1 7/8" NEW CONCRETE SLAB 124 STORAGE F.O. STUD F.O. EXISTING BUILIDING 1" B.E.J. 10'-4 3/8" 11'-7 1/2" 110 CONFERENCE 101 RECEPTION 117 RESTRM. 116 RESTRM. 100 EXIST. STAIR 107 OFFICE 102 OFFICE 103 OFFICE 104 OFFICE 105 OFFICE 111 MECHANICAL 114 EXIST. STORAGE 106 OPEN OFFICES 112 OPEN OFFICES 113 STORAGE 115 CORRIDOR 121 EXIST. ELEV. 125 CLOSET 120 EXIST. STAIR F.2 15 7 8 101 7 6'-6" 6'-6" 6'-6" 6'-6" 3 A303 13'-0" 13'-0" 3'-10 1/2" 8 A303 TYP. TYP. 6'-0" 8 A303 3 A303 4" CONCRETE FILLED STEEL PIPE BOLLARD SET IN CONCRETE, 4'-0" HIGH, PAINT SAFETY YELLOW. SEE DETAIL THIS SHEET 1'-6" 5'-8 1/2" 1'-6" 1'-6" 1'-4 3/8" 3'-6" 1'-5 3/4" 12'-0" 1'-4 3/8" 19'-5" 6'-4 1/2" 6'-8" 6'-4 1/2" 1'-1 5/8" 5'-4 3/8" 6'-2 5/8" 19'-8 1/2" A303 A 6" CONCRETE WITH 6" X 6" #10 WWM OVER 4" COMPACATED STONE 3'-0" 3'-0" 6" STEEL CAP - WELD TO STEEL PIPE, GRIND SMOOTH AND PAINT 4" DIA. SCHEDULE 80 STEEL PIPE - CONCRETE FILLED. PAINT SAFETY YELLOW TOP OF CONCRETE MIN. 18" DIA. x 42" DEEP CONCRETE FOOTING ARCHITECTURE INTERIOR DESIGN Drawn: Project Manager: Designer: THIS DOCUMENT IS THE SOLE PROPERTY OF HBA ARCHITECTURE & INTERIOR DESIGN, INC.; A PROFESSIONAL CORPORATION, VIRGINIA BEACH, VIRGINIA. THE REPRODUCTION IN WHOLE OR IN PART OR THE MODIFICATION OF ANY DETAIL OR DESIGN MAY NOT BE MADE WITHOUT EXPRESS WRITTEN CONSENT. COPYRIGHT c 2021, HBA ARCHITECTURE & INTERIOR DESIGN, INC. ONE COLUMBUS CENTER, SUITE 1000 VIRGINIA BEACH, VIRGINIA 23462 PERMIT REVIEW SET 01-24-2025 C:\Users\stevem\Documents\TB_Vacation_Hilton_Head Exterior_R24_stevem@hbaonline.com.rvt 1/26/2026 3:21:23 PM BEACH PROPERTIES OF HILTON HEAD 862 WILLIAM HILTON PKWY, HILTON HEAD, SOUTH CAROLINA, 29928 EXTERIOR RENOVATIONS TO 24013 A101 FIRST FLOOR NEW WORK PLAN DRW PRM DSG 05-05-2025 PERMIT/CONSTRUCTION PERMIT/CONSTRUCTION 1/8" = 1'-0" FIRST FLOOR - NEW WORK PLAN NEW WORK NOTES # TRANSITION STRIP - SCHLUTER SCHIENE, SATIN ANODIZE D ALUMINIUM, COORDINATE HEIGHT WITH CPT-1 AND LVT-2 1 <varies> 2 NEW ADDITION - SEE SECTIONS. 3 PLANTER BED - SEE LANDSCAPE DRAWINGS 4 NEW TABBY CONCRETE SIDEWALK WITH BRICK PAVER EDGIN G, SEE LANDSCAPE DRAWINGS 5 NEW ENTRY CANOPY 6 ALIGN FACE OF CANOPY WITH EXISTING FACE OF COLUMN 7 NEW STOREFRONT AND ENTRY DOORS 8 <varies> 9 NEW PROPANE ENCLOSURE 10 DRY FOUNTAIN WITH SCULPTURE. 11 LANDSCAPE AREAS - SEE LANDSCAPE DRAWINGS. 12 NEW HVAC ENCLOSURE 13 BUILDING EXPANSION JOINT, SEE 9 AND 10 ON A303 15 DUMPSTER ENCLOSURE. SEE ENLARGED PLAN THIS SHEET 16 LOCKERS. PROVIDED AND INSTALLED BY OWNER. GC TO P ROVIDE POWER AND DATA. 1/4" = 1'-0" PROPANE ENCLOSURE KEY PLAN PLAN NORTH PLAN NORTH PLAN NORTH REVISION 7 7 01/26/2026 1/4" = 1'-0" DUMPSTER ENCLOSURE PLAN NORTH 7 3/4" = 1'-0" BOLLARD DETAIL 7 7 7 r h@gar«aapg@ea$/0$$0¥ $$ {43#$we%#9%949/1$%/94$9.%99% CJ) 9/·.. 0_"-Y"-.~YA~.y• ~,92222,RR,;;:;;; " >,'/~2_'/Y~-8:%%199%% %8%%e9Mb 9ho> $$/$4%4$$$$$ atea..-$«tdgdi@"$$$ hie#92097008\1292th9p1Gagel«g«gdg@gad@ ad#gad@egadg@gad@ ahgad@@g@dg@@gad« ad@a«g@«g@egg@age 4#/%/9899%/%//%/99%/$%/%949%/9/%999%9$%/%999%/9%$ 0 0 0 -0 De>< ( ' 2] 2[ 2 3- 3< « < ] ' 2( ')-« 3-[ · 2« -« < ( ')< ( ')-] ' 2 ' 00 D • [] ¢ I I L , " 0 I lJ w "[so[o .1_siege_? ...3') ,-, ,'.s.er• -. le'. Gs_._ -~ ·_ .. t •- .///I I L h· t '--------~----- .•. I l: r-- -------------- ~ @ D> [> '·.·.«-<+- ' . < •• ··1 a. ", .·: ... . «' , A Le/ .•• .•·.. 1.·t •··~·~-:~--•~~-•- -·--'->-k- ~-~-~•-~-·~-.~.:~:~:f ~- -• • ' I : I 4 i • t \ I . ..«:\'.' \ - · ..:... ,, .. -~-· />j ' i i : " I •t- _ ·. 1 ;'. ·.·.. ··c···1···.····· .•.. • • : -: ~••··•·'· ·' -i- . .. . . .... .. . .. . . ...• .. • I --o+--rJfJ '. I I.·· .. · .. •··.·.· •••·.·-~c::--- IV Ee •.»~·. ~-- ~,\\ •·.·. :~:t,1!~,-:_:_,_~~----\--llil;i---:-'7 ,_::--~~ :- - H--+=lgj b □ 0 ____,, .E. ~ • ,#%%# %~¼~92 s AA9,EE gee; : ·:;: ·, : .· ·' ,:· .. : '. ., .- J //::/,~/,··« '¼W,c0";j/;j/,~1/,··« '¼W,@ • 1- I 1tjv71 -1/, W«'.0.(,/ • '. · -~. /Z½.'.1/08:"//, ·//, .,/, '1/,(8f0,'.1/,(~ W«'.00 «.«Inel-7-F--- 4$% bi$$ b$239$2$$]-l-} +' h%2b%2} ' pi5$23i5$2bi$, $%$2$2$Sp$22,@22929229$2h$} n[TE,- l toecaps±l Egg n. - lid$@$9@egg9$id$4ti@@$hf$eea/$$$$SC2eve0eeeota8f6. ·IMS@- - " a..R,Jg39s9293931 42g 2.+ " [%2@%#l I:g 222994, 2942949g # k$] • [qii@age g«gad@ad#gad#gdtga«gad&ga@gad"gad&gad«tgad@gad@gad@gaga"gs@ ff] ' .9gag1.,,9LI,,1J/·». • 6$ a· BS59%$)3$$ 6%%%$$$59959Jg• ' ; • f!.~;;: • D A D - "' '. . ;;;ffl 1//"'0 ;;: W,!'W' 0((~Z'~'2· .+°.' pp2hp,a Bl' pp be> 2 AM 2)....p@@4 [pg. [id@e2h$hgo9%9@%••• ••••' ~. 4i,.. , . yY yY z_Y'/•.o > b,Np), - 4Bl p39)N)} 2 3)))23))3)$%,•. e B d . {/(//g .·[Eh pg, # 0g@e•••• •'. ..: 1/iYf1• ~ ~ );,·· ,_. ·• 0 ~;;;~/~ ••• J• [Pe@a«gt l}.- • [@ ff _EOE29BEBEE, =. Baba Rd s tee Ne@le@Ree +. '. , . Yf:t:;;;1" J 'c D rr ~ , '. ~~;;::,;;.-~~~Yf'/Y ,/, ),)) 0 '?0 )i1 __, • Y'/0 ;; = D 1' • ,. •. ~YY;;;~ ~<;~<;~ 0"'~ ~ W '; . . : • :,. •, ___, ~ ~ .. -. ;. , ~~ w,_ ;;;WW-, s ~ '@~~, •• - >: , ~."', l ~·.· ·. ~-0.~ W-0,~ ' ,.,,0~.s •bb,- ].. Ph)h $b)hp 22BR• t • ~~ " ~ ' • . . ~;;; yy::,; 1/,1"' ~ .q4 A fl [] 5 #3 la, EE #el e ii,cs u me Ilp@es. . . • yyw,_~ t--------, I IQ 1/, • " , ~ , "' - I [ESQ94QM4q [] r= WT S] n, bfKd• •s b8}j)} B] ~·~·· .. •- ....... · 1··· . ~.,1: ., ~ tJ D / ~~ : . yy.,-,w,<~ "~"0~• • • . • • • • "'""-- • • ½< ¼ ---, fil{------ L.,., ' ' • W-0./1/W ' --~' •••: • • . ·- . ' . • ,• ~I • ' = ' I W'Z;;i/41W _J 0""'"'•• > tr1 • < «(&_.__. ', lt. 9 $pi$Si$ 5$pSi$4· • [e e ?!;/~'~W/4'i1/';;(.«),'i1//4'1/,(§'Y~~W/4'i1/>,j • ~ ' J . "--- ~ • y~ D ~ ~ ~ ««$ $ I •• s $ff K @ ea,994«.IE,st fl lks.Left' RteW0.Y~~s'Y.0s~f!.0s;;;* YY/4~s'Y/4~~ • •• • 1 ·t· · " . ·, •. , ~ "'-' • '~ W>" '"" W0.))'!S¼::,; WA~./& 0 :;,; WA~/ • • • I • 1 ,e • ' 0 ~ ii( G:;,; ~ 2299909000919293999%0 -If ·I 1 e tage as@@ @@gs I • l kd Ca [@@?2le 5$"5$5jib$j@Si$Si$Si$@1"5@5$@Si$@$} ..--le ..+! b55j@Si@Si"S0$}$$$0fit$$$$ jobi}, w~J¼~·Y'/•J¼.01 • ••ht • •• • ' __ ~~~- .YY"),Sjj,,m;,,,1';,J'+-,++- ,~.,,~~;;v~ "1/@s:,~;;,,vA'w~I " l"J I t= -- - ~ ++- □ 0 ~46$$ { h--, [@ {F 7.77"Ts v T [ $«$@/W)S,;,@)S '~ @!ii~& ~.;;0; ~ •.• •.• I '1 • • .• . I I O '1 CD ""I//'.""~ .1/,1/, ~1°~ '·. "' , •.. · ·,.• \: /.:. ft~~2le@le].e I·. + fed@@@Re $SM$S] ·.]'.·. ! ' 'Behl ~1~. • • • I +. . ·,◊ >- 0 D D .. --~----<+- ~.•••• (D~~/ ,. I I " • • • ·4i a{ WV/0~0, • 7"'7)"'7~AV~ • I • ' .. •• •.' ..... I w ~ 1/,~/X?i~ :gt4 pt«egg.,[1.-' [if$id$$Sh 1_. O h _/t4_±l ± -:l:·I ,B9,}G hT- T. i " H4 F ((([[•••• I B BR' "fl-ill Ji Ee ~I '•I◊: 0 L...JI w' \ I J ~~I~~~i""t D> I' [$$14@$1$$$$• 1i I [«g«gad#4#@#4 El . 'lh [8@f@@#2 Ji hi_id }• Y• ff: □ ' +=.. pa ()• Q· •• ) I ..... ,': ~ □ □ : - ....:•,.'• . ti ,__ >., rh • R..... ·, 1'l« ~ ----·· .• ... ~• » $ f\ [£ l@ [ .ll [] + l, " @<,el@di," '3j} I[pl%73 • [dig@jd [ Hf$9@a@$f//- Bl@@a pp2De; ,• b9} 7UWOO 577 3$895// ID. ~,~'4, I ~ D O ;//%~,~~~.3%%OS%%) [hi b6)%$• • S"'WA'YZ D II 1/,, ,0 bps252$ 'i Bl% ifie@sL l IE@st• s i@& i ?@2?@@?e e 7.llb$$%] Bo: $5$$ "Et,gag1 t ii9,_' • -•. ., t-. • ~ ~~ =====c::i 1---- , II "-''«"--JS ~~ ¼ ~/• , • i , ~ s;%>,>,';;(.{0~'v -$5;{0"'~"" , "$5;@ W "'~W '~ c" /s B9,99,899ch%}?}, %%,,}? ??99, ??i9,} 2))2)%%9)),pSE 2DUE 322B22 I • -1h$ 9$1098$€ 0%4292$5$. 129$2$$i RA #9ea92s .e. « « « 2•• b$ #5%$%$$ 55%5%# 4#$5$0$ 59#$ 4%$ :. ·: ...--.: - · .• · .. · · ·. · 1 · · .- ,.., .. · •. ,·. f ~ -:~. . ~ · · ~• • '4, • • 's , ., t>• ,. , •• _'•": ' ' , • .., , ~ .:u•':' l., ' I 11 -1 IV///.>?///>?///.?"...,....- •Ey_ eEIl._Soll •_!I-.- :·~•,··'; ..27r7 mm} O @ B 0 .3bgAx2d': %2'g '9 %o ut!Hu,,s"{i3 ",s$%0)%%...s$,sOe, '%255 'M-s; zg zo: "2 :-; <$8i£@ !5'=-· tT, i=: gg} =z;: jg Ss-. 5 _Ne2g.. 6 i's•. i gee285,... 8,s$4iioi,Viiii Page 47 of 68 2 A301 1 A301 4 A301 3 A301 2 A102 (9' -0") 2.3 3 4 5 A B C 4 A302 4'-7" 12'-0 1/2" 4'-11" 7'-10" EQ EQ 7'-0" 4'-8" 5'-4" 1'-0" EQ EQ 1'-1 1/2" 1'-1 1/2" 4'-6" 10'-0" 10'-0" 4'-6" 1'-1 1/2" (9' -0") FRAME AROUND EXISTING CONDUITS ABOVE G 2 2.7 F F.2 1 (9' -0") 7 +9'-0" A.F.F. CEILING HEIGHT 2" 6" 6" METAL STUD FRAMING WITH 5/8" GYPSUM BOARD ACOUSTICAL CEILING TILE EXISTING CONSTRUCTION LED RECESSED LIGHT FIXTURE, SEE ELECTRICAL SUSPENDED GYPSUM BOARD CEILING TO BE LEVEL 5 FINISH AND PAINTED. SEE FINISH SCHEDULE. CEILING HEIGHT ABOVE FINISH FLOOR (X'-XX") 2 x 2 ACOUSTICAL CEILING TILE AND GRID (ACT-1) TYPICAL UNLESS OTHERWISE NOTED LINEAR LIGHT FIXTURE, SEE ELECTRICAL EXIT SIGN ARCHITECTURE INTERIOR DESIGN Drawn: Project Manager: Designer: THIS DOCUMENT IS THE SOLE PROPERTY OF HBA ARCHITECTURE & INTERIOR DESIGN, INC.; A PROFESSIONAL CORPORATION, VIRGINIA BEACH, VIRGINIA. THE REPRODUCTION IN WHOLE OR IN PART OR THE MODIFICATION OF ANY DETAIL OR DESIGN MAY NOT BE MADE WITHOUT EXPRESS WRITTEN CONSENT. COPYRIGHT c 2021, HBA ARCHITECTURE & INTERIOR DESIGN, INC. ONE COLUMBUS CENTER, SUITE 1000 VIRGINIA BEACH, VIRGINIA 23462 PERMIT REVIEW SET 01-24-2025 C:\Users\stevem\Documents\TB_Vacation_Hilton_Head Exterior_R24_stevem@hbaonline.com.rvt 1/26/2026 3:21:23 PM BEACH PROPERTIES OF HILTON HEAD 862 WILLIAM HILTON PKWY, HILTON HEAD, SOUTH CAROLINA, 29928 EXTERIOR RENOVATIONS TO 24013 A102 FIRST FLOOR REFLECTED CEILING PLAN DRW PRM DSG 05-05-2025 PERMIT/CONSTRUCTION PERMIT/CONSTRUCTION 3/16" = 1'-0" FIRST FLOOR REFLECTED CEILING PLAN 1 1/2" = 1'-0" A102 A102 2 SOFFIT DETAIL CEILING LEGEND GENERAL CEILING NOTES 1. UNLESS OTHERWISE SHOWN, CEILING TILE SHALL BE CENTERED IN EACH ROOM, IN ACCORDANCE WITH LAYOUTS SHOWN. 2. THE CEILING CONTRACTOR SHALL VERIFY ALL LAYOUTS WITH THE ACTUAL FIELD CONDITIONS AND SHALL MAKE ADJUSTMENTS NECESSARY TO ELIMINATE ADDITIONAL, SMALL, OR ODD PIECES OF CEILING TILE. 3. CUT AND COPE EDGES TO MATCH UNCUT TILE. 4. ALL DIMENSIONS ON CEILING PLAN ARE TO FINISHED SURFACES AND CENTERLINES OF FIXTURES. 5. CENTER ALL LIGHT FIXTURES, DIFFUSERS, ETC. IN CEILING TILES UNLESS OTHERWISE NOTED. PLAN NORTH REVISION 7 7 01/26/2026 CEILING PLAN NOTES # 1. PROVIDE ONE LAYER 1/2" TO UNDERSIDE OF COLD FORM METAL FRAMING 7 □ 0 0 0 00 ' «.' o ' ,' iI ' O t- +---I t- + I o J _1.he + + o [ • $ <j---------------+----------------iLi # oO iI II o 0 n a- ---+ O ---+ t- t- II ' -·11 o y 11 • l1 l1 tn IJ O • 1 _,_o _j □I}.' 0 lI i '} l] [,, 1 I [ '] r l I , , , , -'I ·;_ '1 I '. L, ':: , , , Lr' -IE O o + + -· o 4 -4 u 1---- r--...... [ ]u --0 Hy , - o - - I I I I - - 1 - - - - - -o o o O o I I 4] [1_' o'- O O O LI O O O O t t-t- O 7 ]- O 7 t- 7 t- t- O I I O o O I 7 'f r r l ot'at1'.J u y, , I [al Page 48 of 68 2 A301 1 A301 3 A302 4 A301 3 A301 5 A302 RD RD OS OS OS 1 A303 1 A303 SIM. SB DS SB DS DS DS DS DS DS SB SB DS DS DS DS DS DS DS FIXED BAHAMA SHUTTER ABOVE, DASHED IN FOR CLARITY (F.V.) 9'-0" +/- (F.V.) 19'-0" +/- (F.V.) 9'-0" +/- (F.V.) 19'-0"+/- (F.V.) 9'-0" +/- (F.V.) 19'-0"+/- (F.V.) 19'-0"+/- FIELD VERIFY (F.V.) 19'-0"+/- (F.V.) 9'-0" +/- (F.V.) 29'-0" +/- L1 L2 L2 L2 L1 L1 L2 L2 L1 L3 RD RD 2.3 3 4 5 A B C BEJ 4 A302 OS 2 A103 TYP 2 A103 SIM 3 A103 G 2 2.7 F 222 OFFICE 221 OFFICE 220 OFFICE 219 OFFICE 223 OFFICE 218 OPEN OFFICE 214 OFFICE 215 OFFICE 216 OFFICE 217 OFFICE 208 EXIST. ELEVATOR EQUIP. 209 EXIST. MECH. 212 MENS 211 WOMENS 202 STORAGE 213 EXIST. IT / ROOF 204 BREAK ROOM 206 EXIST. ELEV 205 CORRIDOR 203 CONFERENCE 207 EXIST. STAIR 210 CORRIDOR 201 CORRIDOR 200 EXIST. STAIR F.2 1 A304 ROOF DRAIN SLOPE OF TAPERED INSULATION 1/4" PER 1'-0" AND 1/2" PER 1'-0" @ CRICKETS OVERFLOW SCUPPER - SEE 1/A303 PROVIDE CONCRETE SPLASH BLOCK PROVIDE 4" DIAMETER 16 OZ. COPPER DOWNSPOUT W/ (2) COPPER STRAPS MIN. CONDENSING UNIT SEE MECHANICAL DRAWING RD OS SB DS PROVIDE 18" SQUARE TAPERED INSULATION SUMP AROUND DRAIN COVER BOARD CENTERLINE OF ROOF DRAIN METAL DRAIN STRAINER-SEE PLUMBING DRAWINGS CLAMPING RING - PROVIDE STAINLESS STEEL BOLTS. APPLY ANTI-SIEZE COMPOUND TO BOLTS ROOF DRAIN PLYWOOD SHEATHING OR METAL DECK DECK CLAMP MEMBRANE ROOFING SYSTEM MEMBRANE ADHESIVE WATER CUT-OFF MASTIC COVER BOARD MEMBRANE ROOFING SYSTEM BOARD INSULATION PLYWOOD SHEATHING PREFABRICATED GALVANIZED STEEL EQUIPMENT RAIL WITH TREADED WOOD NAILER SHEET METAL CAP FLASHING METAL COUNTER FLASHING 1'-6" BASE FLASHING MEMBRANE ROOFING SYSTEM FULLY ADHERED IN VERTICAL APPLICATION ARCHITECTURE INTERIOR DESIGN Drawn: Project Manager: Designer: THIS DOCUMENT IS THE SOLE PROPERTY OF HBA ARCHITECTURE & INTERIOR DESIGN, INC.; A PROFESSIONAL CORPORATION, VIRGINIA BEACH, VIRGINIA. THE REPRODUCTION IN WHOLE OR IN PART OR THE MODIFICATION OF ANY DETAIL OR DESIGN MAY NOT BE MADE WITHOUT EXPRESS WRITTEN CONSENT. COPYRIGHT c 2021, HBA ARCHITECTURE & INTERIOR DESIGN, INC. ONE COLUMBUS CENTER, SUITE 1000 VIRGINIA BEACH, VIRGINIA 23462 PERMIT REVIEW SET 01-24-2025 C:\Users\stevem\Documents\TB_Vacation_Hilton_Head Exterior_R24_stevem@hbaonline.com.rvt 1/26/2026 3:21:24 PM BEACH PROPERTIES OF HILTON HEAD 862 WILLIAM HILTON PKWY, HILTON HEAD, SOUTH CAROLINA, 29928 EXTERIOR RENOVATIONS TO 24013 A103 FIRST FLOOR ROOF PLAN Author Checker Designer 05-05-2025 PERMIT/CONSTRUCTION PERMIT/CONSTRUCTION 3/16" = 1'-0" SECOND FLOOR NEW WORK AND FIRST FLOOR ROOF PLAN FIRST FLOOR ROOF PLAN LEGEND 3" = 1'-0" A103 A103 2 ROOF DRAIN 1 1/2" = 1'-0" A103 A103 3 ROOF EQUIPMENT SUPPORT RAIL REVISION 7 7 01/26/2026 7 0 0 0 (I] 0 O 0 - J HI I□ J -- 'l' ' e l 1 - 1 \\- I 1/\ - I gLl 3 [j I l I )I I C - 1/\ 11 } #at Ht ) /\ i 0 \i~i,~ I I I I I I I I I I I I I I I L-' ±t3ttt i t [LE I I -111 0 I - 0 I'J I \Vt 1 i- i! i l ] 1, . '~~.~----~ -" 1- ~-,( "~~~~~~~)'~-------" ;---:---~{)--:' _- -8-I I I 0 I I I I 0 0 +{u 0 )# Page 49 of 68 TOP OF BEAM (+/-12'-0") TOP OF RAFTER +/-12'-0" FIRST FLOOR 0'-0" ROOF BEARING +/-22'-6" DS DS DS DS 1 11 2 2 4 3 6 7 8 8 8 L2 L1 L2 11'-6" 2'-9" 5 SIM 7'-2" G FF.2 11 11 3 A302 TOP OF RAFTER (+/-12'-0") ROOF BEARING +/-22'-6" SECOND FLOOR +/-12'-6" FIRST FLOOR 0'-0" DS DS 2 A303 1 2 1 2 6 7 8 8 9 2.3 345 4 A302 8 8 6 4 A303 10 26'-8" 5'-0" SIM SIM 22.7 10'-0" 11 11 11 11 11 TOP OF RAFTER (+/-12'-0") TOP OF BEAM +/-12'-0" ROOF BEARING +/-22'-6" FIRST FLOOR 0'-0" DS DS DS DS 1 1 2 2 3 6 7 88 8 L1 L2 A B C 4 11'-6" 2'-9" 7'-2" GFF.2 7 1 A304 12 13 1 A301 2 A301 5 A302 ROOF BEARING +/-22'-6" SECOND FLOOR +/-12'-6" FIRST FLOOR 0'-0" DS DS 1 1 1 11 2 2 2 2 33 4 5 7 8 8 L2 L1 L3 L2 L1 7 2.3 3 8 8 11'-8" 2'-9" 2'-9" 11'-6" SIM SIM 5 SIM 7'-2" 7'-2" 2 2.7 11 11 11 11 9'-0" +/- 29'-0" +/- L1 L2 L3 CENTER BRACKETS ON CENTERLINE OF EXISTING ALUMINUM STOREFRONT BEYOND, TYP. ALL DIMENSIONS ARE TO BE VERIFIED IN FIELD PRIOR TO FABRICATION. 19'-0+/- SLAT QUANTITY HAS BEEN REDUCED BY 1/3 ARCHITECTURE INTERIOR DESIGN Drawn: Project Manager: Designer: THIS DOCUMENT IS THE SOLE PROPERTY OF HBA ARCHITECTURE & INTERIOR DESIGN, INC.; A PROFESSIONAL CORPORATION, VIRGINIA BEACH, VIRGINIA. THE REPRODUCTION IN WHOLE OR IN PART OR THE MODIFICATION OF ANY DETAIL OR DESIGN MAY NOT BE MADE WITHOUT EXPRESS WRITTEN CONSENT. COPYRIGHT c 2021, HBA ARCHITECTURE & INTERIOR DESIGN, INC. ONE COLUMBUS CENTER, SUITE 1000 VIRGINIA BEACH, VIRGINIA 23462 PERMIT REVIEW SET 01-24-2025 C:\Users\stevem\Documents\TB_Vacation_Hilton_Head Exterior_R24_stevem@hbaonline.com.rvt 1/26/2026 3:21:26 PM BEACH PROPERTIES OF HILTON HEAD 862 WILLIAM HILTON PKWY, HILTON HEAD, SOUTH CAROLINA, 29928 EXTERIOR RENOVATIONS TO 24013 A201 ELEVATIONS Author Checker Designer 05-05-2025 PERMIT /CONSTRUCTION PERMIT /CONSTRUCTION 1/8" = 1'-0" A201 A101 3 EAST - NEW WORK 1/8" = 1'-0" A201 A101 2 NORTH - NEW WORK 1/8" = 1'-0" A201 A101 4 WEST - NEW WORK 1/8" = 1'-0" A201 A101 1 SOUTH - NEW WORK NEW WORK NOTES - ELEVATIONS 1 PROVIDE ALUMINUM FRAME FIXED BAHAMA SHUTTER. SEE S ECTION 5/A302 2 PROVIDE FABRIC AWNING CANOPY OVER ALUMINUM FRAME S YSTEM. SEE SECTION 5/A302 3 PROVIDE LIGHT FIXTURES, SEE ELECTRICAL. 4 NEW ENTRY CANOPY. 5 NEW STOREFRONT AND ENTRY DOORS. 6 NEW ADDITION - SEE SECTIONS. 7 AFTER REMOVING EXISTING CANOPY, REPLACE, PATCH, AN D REPAIR MISSING PORTION OF EXISTING WALL, MATCH EXISTING. SEE GENERAL ELEVATION NOTE THIS SHEET. 8 PROVIDE 4" DIAMETER 16 OZ. COPPER DOWNSPOUT W/ (3) COPPER STRAPS MINIMUM AT QUARTER POINTS. 9 REPLACE, PATCH, AND REPAIR MISSING PORTION OF EXIS TING HALF ROUND COPPER GUTTER, MATCH EXISTING. 10 NEW HVAC ENCLOSURE, SEE PLAN. 11 PROVIDE NEW CLEAR 1" INSULATED GLASS UNITS WHERE EXISTING GLASS UNITS WERE REMOVED. PROVIDE NEW BACKER ROD ADN SEALANT AT PERIMETER 12 PREENGINEERED ALUMINUM CANOPY 13 LOCKERS BY OWNER 1/4" = 1'-0" FIXED BAHAMA SHUTTER EXTERIOR FINISH LEGEND GENERAL ELEVATION NOTES: 1. AT ALL EXISTING EXTERIOR STUCCO WALL FINISH PROVIDE REMEDIATION, REPAIR AND NEW STO ACRYLIC FINISH OVER EXISTING CEMENT STUCCO. 2. PROVIDE AND REPAIR ALL DAMAGE STUCCO, PARTIAL AREAS OF REMOVAL AND NEW AREAS OF NEW INFILL WITH (QUIKRETE BASE COAT STUCCO). APPLY (QUIKRETE BONDING ADHESIVE) TO EXISTING STUCCO. APPLY (TROWEL-ON CONVENTIONAL CEMENT STUCCO COAT) TO SMOOTH OUT EXISTING ROUGH STUCCO SURFACE (QUIKRETE BASE COAT STUCCO). APPLY STO BASE AND STO REINFORCING MESH. APPLY (STOLIT ACRYLIC TEXTURED FINISH) SMOOTH FINISH OVER STUCCO. 3. WHERE INSULATED GLASS UNITS ARE TO REMAIN RAKE AND REMOVE SEALANT AND BACKER ROD COMPLETE. PROVIDE NEW SEALANT AND REVISION 7 7 01/26/2026 7 DESCRIPTION MANUFACTURER COLLECTION STYLE COLOR STUCCO BENJAMIN MOORE 967 CLOUD WHITE STOREFRONT FRAMING KAWNEER DARK BRONZE PAINT BENJAMIN MOORE 2134-20 MIDSUMMER NIGHT AWNING COASTAL CANVAS/SUNBRELLA AWNINGS/PERGOLAS MARINE TOPS AND COVERS 4688-000 BASIL FENCE WOLF PORCH SILVER TEAK SHUTTER COASTAL CANVAS DARK BRONZE WALL SCONCE COOPER LIGHTING BRONZE METALLIC WALL EXIT LIGHT LITHONIA LIGHT DARK BRONZE ABC LOCKERS ALUM. CANOPY DARK BRONZE BROWN GREY (RAL 7013) 7 ◊ t t t ◊ DARK BRONZE ~--..--....--....--....--....--....--....--....--....--..--....--....--....--....--....--.. .......... ..--....--....--...---....--....--....--..+ I I I I I I I I M I I M I I I I N I I M M I M I f 0 O O[fmpjjyg_[jy[ r I • O [_ ]\ LT_ _] • ill/ [. i 2]lg] le]/'ea//ads'ate./]hr]$' 1.las4 Lb«Lah]/ • u.[ff I" fJf [] TIfffTflnl [f [cl h if "rm] /-5$$$±5±#f±£5$$]-:8°.. []' []' [] 0 >AI i i9 9 9 I j I I - n B Ill □ ofl II III fl LL__ A I I 011 111 11 □ I -"., , " I I coI I I 11 ..J □ I I 9 i io Page 50 of 68 TOP OF EXISTING PAVMENT CONCRETE FOOTING - SEE STRUCTURAL 12" CONCRETE MASONRY UNIT FILL SOLID W/ GROUT EXTERIOR FINISH SYSTEM PRECAST ARCHITECTURAL CONCRETE NEW 2x6 WOOD-SLAT FENCE FOR PROPANE ENCLOSURE ASPHALT PAVEMENT REPAIR - SEE CIVIL DRAWINGS HORIZONTAL JOINT REINFORCEMENT @ 16" VERTICALLY 6x6 WOOD POST BEYOND, TYP. SEE DETAIL 8/303 FOR FENCE POST FOOTING AND POST BRACKET DOWEL 7 A303 1"TYP. 3" 7'-4 3/8" 4" 1/2" 7'-0" 4'-0 3/8" 4" 03 00 00 CONCRETE FOOTING - SEE STRUCTURAL 12" CONCRETE MASONRY UNIT FILL SOLID W/ GROUT EXTERIOR FINISH SYSTEM PRECAST ARCHITECTURAL CONCRETE TOP OF GRADE HORIZONTAL JOINT REINFORCEMENT @ 16" VERTICALLY 1" TYP. 4'-0" NEW 2x6 WOOD -SLAT FENCE FOR MECHANICAL ENCLOSURE 4x4 WOOD POST BEYOND, TYP. SEE DETAIL 6/303 FOR FENCE POST FOOTING AND POST BRACKET DOWEL 5 A303 4" 4" 1/4" @ STORAGE 10 1/2" 8" MIN. 4" 2" .050 PREFINISHED ALUMINUM COPING W/ CONTINUOUS CLEAT MEMBRANE ROOFING SYSTEM 6" COLD FORMED METAL FRAMING - SEE STRUCTURAL 2X TREATED WOOD BLOCKING 4" HIGH X 8" WIDE (CLEAR) X .040 ALUMINUM THROUGH WALL OVERFLOW SCUPPER W/ CONTINUOUS WELDED CORNERS HEMMED EDGE SET WALL FLANGE IN SEALANT - ALL 4 SIDES EXTERIOR STUCCO WALL COVERING BACKED W/ AIR AND WATER -RESISTIVE BARRIER AND DRAINAGE MAT 5/8" GLASS -MATT GYPSUM WALL SHEATHING COVER BOARD TAPERED BOARD INSULATION @ CANOPY 10 1/2" 2 1/2" COLD FORMED METAL FRAMING - SEE STRUCTURAL ROOF SHEATHING SECOND FLOOR (+/-12'-6") FIRST FLOOR (0'-0") EXISTING CONSTRUCTION TO REMAIN EXTERIOR STUCCO WALL COVERING TO MATCH EXISTING, SEE GENERAL ELEVATION NOTE ON A201 COLD FORMED METAL FRAMING INFILL 1/2" GLASS -MATT GYPSUM WALL SHEATHING GLASS FIBER BATT INSULATION - R-19 EXISTING STUCCO WALL FINISH, SEE GENERAL ELEVATION NOTE ON A201 (+/- 4'-0") (+/- 7'-6") EXTERIOR STUCCO WALL COVERING BACKED W/ AIR AND WATER -RESISTIVE BARRIER AND DRAINAGE MAT 1/2" GLASS -MATT GYPSUM WALL SHEATHING COLD FORMED METAL FRAMING INFILL GLASS FIBER BATT INSULATION - R-19 6x6 WOOD POST PRESERVATIVE TREATED PROVIDE "SIMPSON POST BRACKET WUB66HDG" 1/2" GALVANIZED THROUGH BOLTS 1'-6" CONCRETE FOOTING 2'-0" EXISTING PAVING 1/2" 4x4 WOOD POST PRESERVATIVE TREATED PROVIDE "SIMPSON POST BRACKET WUB44HDG" 1/2" GALVANIZED THROUGH BOLTS 1'-4" CONCRETE FOOTING 2'-0" 1/2" NEW 2x6 WOOD -SLAT FENCE FOR PROPANE ENCLOSURE 6x6 WOOD POST COLUMN SEE 3/303 11 1/2" 5 1/2" 3 GA GALVANIZED 3" WIDE L -BRACKET 3" 4" 7" 3" 2" 2" 5/8" EXPANSION BOLTS 5/8" THROUGH BOLTS W/ WASHERS NEW 2x6 WOOD -SLAT FENCE FOR MECHANICAL ENCLOSURE 6x6 WOOD POST COLUMN SEE 3/303 10" 5 1/2" 3 GA GALVANIZED 3" WIDE L -BRACKET 3" 4" 7 1/2" 5/8" EXPANSION BOLTS 5/8" THROUGH BOLTS W/ WASHERS 3 3/4" METAL TERMINATION BAR SEALANT SHEET METAL FLASHING AND TRIM - 2 PIECE .040 METAL COUNTER FLASHING, PROVIDE FASTENERS @ 12" O.C. MEMBRANE ROOFING SYSTEM FULLY ADHERED IN VERTICAL APPLICATION EXISTING CONSTRUCTION TO REMAIN EXISTING STUCCO WALL FINISH, SEE GENERAL ELEVATION NOTE ON A201 LINE OF COPING BEYOND MEMBRANE ROOFING SYSTEM COVER BOARD TAPERED BOARD INSULATION SPONGE TUBING EXPANSION JOINT FILLER HOT AIR WELD FASTENING PLATE 1" BEJ 5/8" GLASS -MATT GYPSUM WALL SHEATHING 6" COLD FORMED METAL FRAMING - SEE STRUCTURAL EXTERIOR STUCCO WALL COVERING BACKED W/ AIR AND WATER -RESISTIVE BARRIER AND DRAINAGE MAT GLASS FIBER BATT INSULATION - R21 PROVIDE "MM SYSTEMS" FLUSHLINE SYSTEM FSWL -100 EXPANSION JOINT 1" BEJ PROVIDE "MM SYSTEMS" EXPANDING IMPREGNATED VANDAL -RESISTANT FOAM SEAL EIV -100 EXPANSION JOINT EXPANSION JOINT FILLER 5/8" GYPSUM WALLBOARD ABUSE RESISTANT EXISTING STUCCO WALL FINISH, SEE GENERAL ELEVATION NOTE ON A201 EXISTING CONSTRUCTION TO REMAIN 2" X 3" X 1/8" ALUMINUM RECTANGULAR TUBING FULLY WELDED PROVIDE 1/2" SLIDING STEEL PIN TO SECURE GATES TO SLAB LOCK HASP DIAGONAL BRACING NEW 2x6 WOOD -SLAT FENCE PRECAST ARCHITECTURAL CONCRETE CAP ARCHITECTURE INTERIOR DESIGN Drawn: Project Manager: Designer: THIS DOCUMENT IS THE SOLE PROPERTY OF HBA ARCHITECTURE & INTERIOR DESIGN, INC.; A PROFESSIONAL CORPORATION, VIRGINIA BEACH, VIRGINIA. THE REPRODUCTION IN WHOLE OR IN PART OR THE MODIFICATION OF ANY DETAIL OR DESIGN MAY NOT BE MADE WITHOUT EXPRESS WRITTEN CONSENT. COPYRIGHT c 2021, HBA ARCHITECTURE & INTERIOR DESIGN, INC. ONE COLUMBUS CENTER, SUITE 1000 VIRGINIA BEACH, VIRGINIA 23462 PERMIT REVIEW SET 01-24-2025 C:\Users\stevem\Documents\TB_Vacation_Hilton_Head Exterior_R24_stevem@hbaonline.com.rvt 1/26/2026 3:21:27 PM BEACH PROPERTIES OF HILTON HEAD 862 WILLIAM HILTON PKWY, HILTON HEAD, SOUTH CAROLINA, 29928 EXTERIOR RENOVATIONS TO 24013 A303 SECTION Author Checker Designer 05-05-2025 PERMIT/CONSTRUCTION PERMIT/CONSTRUCTION 3/4" = 1'-0" A303 A101 3 REVISED COLUMN @ PROPANE AND DUMPSTER ENCLOSURE 3/4" = 1'-0" A303 A101 4 COLUMN @ MECHANICAL YARD 3" = 1'-0" A303 A103 1 OVERFLOW SCUPPER @ STORAGE 3/4" = 1'-0" A303 A101 2 SECTION 3/4" = 1'-0" A303 A101 8 6 X 6 WOOD POST DETAIL 3/4" = 1'-0" A303 A101 6 4 X 4 WOOD POST DETAIL 3/4" = 1'-0" A303 7 COLUMN BRACKET DETAIL 3/4" = 1'-0" A303 A303 5 COLUMN BRACKET DETAIL 1 1/2" = 1'-0" A303 A302 9 ROOF DETAIL - BEJ 1 1/2" = 1'-0" A303 A101 10 PLAN DETAIL - BEJ REVISION 7 7 01/26/2026 7 7 1/4" = 1'-0" A303 A101 A DUMPSTER ENCLOSURE ELEVATION 7 0 ¢ ¢¢¢I I ] •'~"~~ \ii__ ,·-:q} 11 . -,t---.' .. ..- •• I i i i i n ]5, ;1_ 2 ,""IHHWSki L i i G) ! 1l+I I I I I / /'•, G) --~ r i I I I I I I I I I I :-·'\: I I I I • /.7 ff,$7I I I I I I I I I,' ''/'' ' -Re" I I I I I I I I I .#$I I : I i F vrI I I,?, : #h 'li Ji1 I , , /I I I I I Ip ( 1; iHJ I] [i iI I I ITh i] [i i+ "i l fl ::~,l]! 4]mm ,,Lt l[][ { ]l [ - 4 I i Page 51 of 68 6'-0" 8" 3'-0" SECOND FLOOR (+/-12'-6") EXISTING STEEL STUDS. SEE STRUCTURAL FOR REINFORCING EXISTING STEEL BEAM AND ANGLES. SEE STRUCTURAL. NOTE! EXISTING FRAMING SHOWN. SEE STRUCTURAL DRAWINGS FOR ADDITIONAL REINFORCING AND STEEL STUD BLOCKING PRE ENGINEERED ALUMINUM CANOPY NOTE! REMOVE EXISTING EXTERIOR FINISH SYSTEM AND SHEATHING AS REQUIRED TO INSTALL STRUCTURAL REINFORCING. INFILL OPENING WITH NEW SHEATHING AND FINISH SYSTEM TO MATCH EXISTING. ARCHITECTURE INTERIOR DESIGN Drawn: Project Manager: Designer: THIS DOCUMENT IS THE SOLE PROPERTY OF HBA ARCHITECTURE & INTERIOR DESIGN, INC.; A PROFESSIONAL CORPORATION, VIRGINIA BEACH, VIRGINIA. THE REPRODUCTION IN WHOLE OR IN PART OR THE MODIFICATION OF ANY DETAIL OR DESIGN MAY NOT BE MADE WITHOUT EXPRESS WRITTEN CONSENT. COPYRIGHT c 2021, HBA ARCHITECTURE & INTERIOR DESIGN, INC. ONE COLUMBUS CENTER, SUITE 1000 VIRGINIA BEACH, VIRGINIA 23462 PERMIT REVIEW SET 01-24-2025 C:\Users\stevem\Documents\TB_Vacation_Hilton_Head Exterior_R24_stevem@hbaonline.com.rvt 1/26/2026 3:21:27 PM BEACH PROPERTIES OF HILTON HEAD 862 WILLIAM HILTON PKWY, HILTON HEAD, SOUTH CAROLINA, 29928 EXTERIOR RENOVATIONS TO 24013 A304 SECTION AT CANOPY Author Checker Designer 05-05-2025 PERMIT/CONSTRUCTION PERMIT/CONSTRUCTION REVISION 7 7 01/26/2026 7 3/4" = 1'-0" A304 A103 1 SECTION AT CANOPY -- - I G) T I I I I I I I I I I I I I I I I I I I I I I rad,l.."""reemI I I f, I I I I I I I I I I I I I I I I I 0 Page 52 of 68 THE CONTRACTOR SHALL VERIFY THAT ALL STRUCTURAL COMPONENTS SHOWN ON THESE DRAWINGS ARE ACCURATE IN REPRESENTING WHAT IS CURRENTLY BUILT. THE CONTRACTOR SHALL NOTIFY THE STRUCTURAL ENGINEER OF RECORD IF ANY AS -BUILT CONDITION DIFFERS FROM WHAT IS DEPICTED ON THESE DOCUMENTS. NOTE REGARDING EXISTING CONSTRUCTION CANOPY STORAGE ADDITION EXISTING BUILDING OVERHEAD CANOPY C 1 D 2 S506 _____________________ PRE -FAB METAL CANOPY, BY MANUF 20' - 9" ± REF ARCH REF ARCH 1' - 6" ± (E) W10± STEEL BEAM , VIF (E) 4" DEEP @ 16" OC METAL STUD WALL (BELOW), VIF HANGER ROD AND CONNECTION BY MANUF, TYP AT 4 1 B/ CANOPY REF ARCH (2) 600S162 -97 BLOCKING W/ 400T150 -54 T&B CLOSURE TRACKS, TYP AT EACH CANOPY CONNECTION LOCATION (E) WALL STUDS, REF PLAN (E) BEAM, REF PLAN PRE -FAB CANOPY AND CONNNECTION BY MANUF, REF ARCH. MANUF USE PL3X3 PLATE WASHER ON INSIDE F.O. STUD 400S162 -68 TIE STUD W/ (4) #10 EACH END, AT EACH HANGER LOCATION T/ (E) SLAB +12'-6"± HANGER ROD AND CONNNECTION BY MANUF HANGER ELEV REF ARCH (2) 400S162 -68 STUD @ EA (E) STUD. FASTEN STUDS TOE -TO -TOE (E) STEEL ANGLE, TYP 400S162 -68 STUD @ EA (E) STUD. FASTEN USING #10 SCREWS AT 12" OC STAGGERED IN TWO ROWS STIFFCLIP AL362. FASTEN TO (E) STEEL ANGLE WITH (2) HILTI X -U PAFs (2) 400S162 -43 BRACE @ EA HANGER ROD 400S162 -43 BRACE @ 16" OC STIFFCLIP AL362. FASTEN TO STUD W/ (3) #12 SCREWS MIN. FASTEN TO (E) SLAB W/ (2) HILTI X -U PAFs (2) VERTICLIP SL400. FASTEN TO STEEL BEAM W/ (2) HILTI X -U PAFs (E) 3"± CONC SLAB ON STEEL DECK (2) 600S162 -97 BLOCKING W/ 400T150 -54 T&B CLOSURE TRACKS, TYP AT EACH CANOPY CONNECTION LOCATION STIFF CLIP AL362 T&B EA SIDE, TYP STIFFCLIP AL362 T&B EA SIDE, TYP THIS DOCUMENT IS THE SOLE PROPERTY OF HBA ARCHITECTURE & INTERIOR DESIGN, INC.; A PROFESSIONAL CORPORATION, VIRGINIA BEACH, VIRGINIA. THE REPRODUCTION IN WHOLE OR IN PART OR THE MODIFICATION OF ANY DETAIL OR DESIGN MAY NOT BE MADE WITHOUT EXPRESS WRITTEN CONSENT. COPYRIGHT c 2021, HBA ARCHITECTURE & INTERIOR DESIGN, INC. PERMIT REVIEW SET ARCHITECTURE INTERIOR DESIGN Drawn: Project Manager: Designer: NOTE: THIS SHEET TO BE PRINTED IN COLOR PERMIT REVIEW SET 999 Waterside Drive Suite 2202 Norfolk, VA 23510 (757) 965-5710 www.brittpeters.com BPA Project #: 240580 ONE COLUMBUS CENTER, SUITE 1000 VIRGINIA BEACH, VIRGINIA 23462 Autodesk Docs://BPA Collaborate R24/240580_STRU_Townebank-Hilton Head, SC_R24.rvt 9/9/2025 2:31:08 PM TOWNE VACATION BEACH PROPERTIES OF HILTONHEAD 862 WILLIAM HILTON PKWY, HILTON HEAD, SOUTH CAROLINA, 29928 EXTERIOR RENOVATIONS TO 24013 S506 OVERHEAD CANOPY PLAN AND SECTION Author Checker Designer 01/24/2025 EXTERIOR REVISION 7 7 KEYPLAN - OVERHEAD CANOPY 1/4" = 1' -0" 1 OVERHEAD CANOPY PLAN 3/4" = 1' -0" 2 CANOPY SECTION ED 09/09/2025 01/26/2026 Q 9 BR I TT,--- AND---ASSOCIATES] ff ,consulting engineers I I 0I I I I I I ] I] I /Lulo,d-l L I I I I ~, IE15]" , , , , , , , , , , , , , , , , ts 3 0 0 0 Ii g- 0 Page 53 of 68 STAIR 1MECH 453 SFCONFERENCEELEVATORSTAIR 2CORRIDORRESTRM.RESTRM. 162 SFSTORAGE183 SFGENERALMANAGER122 SFFINANCIALMANAGER 119 SFRESERVATIONSMANAGER 130 SFBUSINESSDEVELOPMENTCOORDINATOR151 SFGUESTARRIVALCOORDINATOR DS DSDSDS DSDS DS DSDSDS DSDS cNEW0102030405152535Scale 1 " = 10' DRB ALTERATIONSUBMITTAL,NOT FORCONSTRUCTION DRAWING NUMBERDRAWING TITLE DESIGN CONCEPTS, DRAWING, SHEETS,LOGOS, SPECIFICATIONS, DETAILS,WRITTEN MATERIAL SHALL NOT BE USEDOR REPRODUCED IN WHOLE OR IN PARTIN ANY FORM WITHOUT PRIOR WRITTENCONSENT OF WJK LTD.© 2026 WJK LTD.THIS SHEET TO SCALE AT: 30"X42" DATE:PROJECT NO.:DRAWN BY:CHECKED BY:FEB 25, 202624095.01JCXX REVISIONS:SITE DEVELOPMENT PLANSFOR862 WILLIAM HILTON PARKWAYTOWN OF HILTON HEAD ISLAND, SOUTH CAROLINABEACH PROPERTIES BUILDING KEY SHEETL100 PAVING SCHEDULESYMB.DETAILDESCRIPTIONSIDEWALK (TABBY CONCRETE WITH BRICKBORDERS)2.1CALL-OUT2.2DETECTABLE PEDESTRIAN PAVING1/L6002/L600SITE DETAILS LEGENDDETAILDESCRIPTION4.1CALL-OUT----- NOTE: MATERIAL SYMBOLS / HATCHES ARE GRAPHIC IN NATURE AND ARE NOT INTENDEDTO BE TO SCALE. REFER TO SITE DETAILS AND LAYOUT PLANS FOR SIZES AND DIMENSIONS. KEY SHEET REFERENCE NOTES:1PLANTING AREA, TYP., REFER TO PLANTING PLANSPROPOSED CANOPY. SEE ARCHITECTS PLANS.PROPOSED EXTERIOR LOCKER SYSTEM. SEE ARCHITECTS PLANS.EXISTING TABBY CONCRETE PAD WITH BRICK BORDER. NOEXISTING FOUNDATION SHRUBS ARE TO BE REMOVED.PROPOSED DUMPSTER ENCLOSURE. SEE ARCHITECTS PLANS. WILLBE LOCATED WITHIN EXISTING ASPHALT PAVED AREA.EXISTING PROPANE ENCLOSURE. DUMPSTER ENCLOSURE WILLCONTINUE MATERIALS AND AESTHETICS PRESENT IN THISSTRUCTURE.WASHOUT AREA TO BE IN SAME LOCATION AS PREVIOUSLY USEDIN ORIGINAL RENOVATION WORK COMPLETED IN 2025. 2435P.A.ACCESS LANE ACCESS LANE PROPERTY LINE PROPERTY LINE PROPERTY LINE PROPERTY LINE 20' BUILDING SETBACK LINE 20' BUILDING SETBACK LINE 50' BUILDING SETBACK LINE 20' BUILDING SETBACK LINE TYPE 'E' BUFFER OPTION 1 (50') NO BUFFER REQUIRED NO BUFFER REQUIRED NO BUFFER REQUIRED BUILDING COVERED ENTRY TOWN OF HILTON HEAD MULTI-USE PATHWAYWILLIAM HILTON PARKWAY PROJECT INFORMATION:ZONINGZONING DISTRICT: LIGHT COMMERCIAL (LC)OVERLAY DISTRICT: ROW-ARTERIAL (COR)USE OF PROPERTY: COMMERCIAL OFFICE (OTHER OFFICE USE)SITEGROSS SITE ACREAGE: 1.3 AC.NET SITE ACREAGE: 1.3 AC.AREA OF DISTURBANCE: 0.0 AC.DENSITYALLOWED TOTAL DENSITY: 13,000 GFA (10,000 GFA PER ACRE)EXISTING BUILDING SQUARE FOOTAGE: 10,350 GFABUILDING HEIGHTMAXIMUM HEIGHT ALLOWED: 45'BUILDING HEIGHT: AS EXISTING <45'SITE IMPERVIOUSMAXIMUM ALLOWED IMPERVIOUS AREA: 33,975 SF (60% OF SITE)CURRENT IMPERVIOUS AREA: 33,480 SF (58% OF SITE)PARKINGMINIMUM NUMBER OF PARKING SPACES REQUIRED: 30(1 PER 350 GFA) (2 ACCESSIBLE SPACES)EXISTING NUMBER OF PARKING SPACES: 42 (2 ACCESSIBLE)FLOOD ZONEZONE 'X' SHOWN ON MAP 45013C461G, DATED 03/23/21 DUMPSTER ENCLOSURE - SEE ARCHITECT'S PLANS 4.1 2TYP.1TYP. 4TYP.5 3TYP. P.A.P.A. 513/L600WASHOUT AREA - CONSTRUCTION ONLY 5.16 6 t >I t oooooo SBSB'[ SDSDSD \• LA11 \I ' >+-!-I] I I I I A@ . .. I I I &ht .. - d. NAILSETINASPHALT ELEVATION=14.18 NAVD1988 ' uA ).. • .• ._T+ EE. Oo L------_J0 T..M. 50'8.SL50'TYPEEBUFFEROPTION1 •WO22 »bp . p < I \ co A \ O0 rII II L '1- '{iy2 =1)@3 %g x4l,x o~Ol2922- .m l.-/ >1 [(-1·-··-··-·I I I-l#f :II I I I I I I I I 1 1 ee'-"i II II II \III I \I II '~: ] y I I I I I I I I II II II II II ] -'-_. I ,,,,. I I ' ,Ii l[f ,"; yI\ III \ III I III I \II I 1 t1[ '"• i__-+l [-l.I ' [ 1> tiII ' III \ IIIN III \II I \ I \ II__I '1I '.v '.I I . I I''I I __./ • -} _,,_,,_[.._jI ---~ \ •--- - Page 54 of 68 STAIR 1MECH 453 SFCONFERENCEELEVATORSTAIR 2CORRIDORRESTRM.RESTRM.162 SFSTORAGE183 SFGENERALMANAGER122 SFFINANCIALMANAGER 119 SFRESERVATIONSMANAGER 130 SFBUSINESSDEVELOPMENTCOORDINATOR151 SFGUESTARRIVALCOORDINATOR DS DS DSDS DSDS DS DSDSDS DSDS DRB ALTERATIONSUBMITTAL,NOT FORCONSTRUCTION DRAWING NUMBERDRAWING TITLE DESIGN CONCEPTS, DRAWING, SHEETS,LOGOS, SPECIFICATIONS, DETAILS,WRITTEN MATERIAL SHALL NOT BE USEDOR REPRODUCED IN WHOLE OR IN PARTIN ANY FORM WITHOUT PRIOR WRITTENCONSENT OF WJK LTD.© 2026 WJK LTD.THIS SHEET TO SCALE AT: 30"X42" DATE:PROJECT NO.:DRAWN BY:CHECKED BY:FEB 25, 202624095.01JCXX REVISIONS:SITE DEVELOPMENT PLANSFOR862 WILLIAM HILTON PARKWAYTOWN OF HILTON HEAD ISLAND, SOUTH CAROLINABEACH PROPERTIES BUILDING PLANTING PLANL5000102030405152535Scale 1 " = 10' PLANT KEY LEGEND PLANTING DETAILSDETAILDESCRIPTIONTREE PLANTING14.1CALL-OUT14.214.3PALM TREE PLANTINGSHRUB PLANTING14.4GROUND COVER PLANTING14.5ROOT BARRIER1/L5012/L5013/L5014/L5015/L501 PLANTING REFERENCE NOTES:1EXISTING FOUNDATION SHRUBS TO REMAIN. NO IMPACT ORREMOVAL.DUMPSTER TO BE SCREENED FROM ACCESS DRIVE BY PROPOSEDSHRUBS.2 cNEW COVERED ENTRY ACCESS LANE ACCESS LANE PROPERTY LINE PROPERTY LINE PROPERTY LINE PROPERTY LINE 20' BUILDING SETBACK LINE 20' BUILDING SETBACK LINE 50' BUILDING SETBACK LINE 20' BUILDING SETBACK LINE TYPE 'E' BUFFER OPTION 1 (50') NO BUFFER REQUIRED NO BUFFER REQUIRED NO BUFFER REQUIRED TOWN OF HILTON HEAD MULTI-USE PATHWAYWILLIAM HILTON PARKWAY 8-MYRC OVERSTORY TREES: 4 TREES PER 100 LF - 10 TREES REQUIRED (10 EXISTING)UNDERSTORY TREES: 5 TREES PER 100 LF - 12 TREES REQUIRED (12 EXISTING)EVERGREEN SHRUBS: 20 SHRUBS PER 100 LF - 48 SHRUBS REQUIRED (48EXISTING)SOUTHERN BOUNDARY (240 LF) - WM. HILTON PARKWAY50' ADJACENT STREET SETBACK - MAJOR ARTERIALTYPE 'E' OPTION 1 (50') MAJOR ARTERIAL BUFFER:WESTERN BOUNDARY (240 LF) - SHARED COMMERCIAL(LC ZONING) PROPERTY LINE20' ADJACENT USE SETBACKNO EXTERIOR BOUNDARY BUFFER REQUIREDNORTHERN BOUNDARY (229 LF) - SHARED COMMERCIAL(LC ZONING) PROPERTY LINE20' ADJACENT USE SETBACKNO EXTERIOR BOUNDARY BUFFER REQUIREDEASTERN BOUNDARY (240 LF) - SHARED COMMERCIAL(LC ZONING) PROPERTY LINE20' ADJACENT USE SETBACKNO EXTERIOR BOUNDARY BUFFER REQUIRED NORTHERN BOUNDARY (229 LF) - SHARED COMMERCIAL (LC ZONING) PROPERTY LINENO EXTERIOR BOUNDARY BUFFER REQUIRED EASTERN BOUNDARY (240 LF) - SHARED COMMERCIAL (LC ZONING) PROPERTY LINENO EXTERIOR BOUNDARY BUFFER REQUIRED WESTERN BOUNDARY (240 LF) - SHARED COMMERCIAL (LC ZONING) PROPERTY LINENO EXTERIOR BOUNDARY BUFFER REQUIRED SOUTHERN BOUNDARY (240 LF) - WM. HILTON PARKWAYTYPE 'E' OPTION 1 (50') MAJOR ARTERIAL BUFFER(SEE BUFFER SUMMARY) BUFFER SUMMARY: BUILDING SIDEWALK 2TYP. 1TYP. TripleShedded WaxMyrtle ommonName t >+I UNDERSTORYTREES MYRCMyricacerifera AbbrevBoLaniALName SOD&MULCH MULCH-SFHardwood oo SBSB,B« SDSDSD :■ LA11 I '. I / -!I I I I I ! <-­tII t \ \1,• NAILSETINASPHALT ELEVATION=14.18 NAVD1988 I l+I -J'O T.B.M. 50'B.S.L. -- 50'TYPEEBUFFEROPTION1 •wWo22 1 I \ II CANOPYLO28LA17 ----, co r( I co \\ -- O0 rII I L @OL2922· ' I lI /? / ' / .rt I ---...... I y, 16 \" 0• I I I I I I .., l--/>1 rt-1..-..-..-. I I -l# :II II I I I I I I I I 1 <'1 II I I \ II II II \I \I \II ° ] !I I I I I I I I I I I I I I I j,/ l /(yI /I /I II \I \I "·I '{>--_l [--.I T.t1I N I 1 I \ II\, II 1 II I\ 1} 1 ~I ht I ' p ti,',1 I',I I ...... , lH _______[.d_~ \ Page 55 of 68 1L501TREE PLANTINGSCALE: N.T.S.2L501PALM TREE PLANTINGSCALE: N.T.S. 3L501SHRUB PLANTINGSCALE: N.T.S.4L501GROUND COVER PLANTINGSCALE: N.T.S.5L501TREE STAKINGSCALE: N.T.S. PLANT SCHEDULE: DRB ALTERATIONSUBMITTAL,NOT FORCONSTRUCTION DRAWING NUMBERDRAWING TITLE DESIGN CONCEPTS, DRAWING, SHEETS,LOGOS, SPECIFICATIONS, DETAILS,WRITTEN MATERIAL SHALL NOT BE USEDOR REPRODUCED IN WHOLE OR IN PARTIN ANY FORM WITHOUT PRIOR WRITTENCONSENT OF WJK LTD.© 2026 WJK LTD.THIS SHEET TO SCALE AT: 30"X42" DATE:PROJECT NO.:DRAWN BY:CHECKED BY:FEB 25, 202624095.01JCXX REVISIONS:SITE DEVELOPMENT PLANSFOR862 WILLIAM HILTON PARKWAYTOWN OF HILTON HEAD ISLAND, SOUTH CAROLINABEACH PROPERTIES BUILDING PLANT SCHEDULE ANDDETAILSL501 BLACK RUBBER HOSE120°120°120°PLANDOUBLE STRAND 12 GAUGEWIREPROTECT TREE TRUNK WITH BLACK RUBBERHOSE OR APPROVED EQUALDOUBLE STRAND 12 GAUGE WIRE WITHGALVANIZED TURNBUCKLE OR APPROVEDEQUAL. MARK AS HAZARD IN LOCATIONWITH HIGH PEDESTRIAN TRAFFIC3" MINIMUM MULCH DEPTH, REFER TO PLANTSCHEDULE FOR TYPESOIL BERM TO HOLD WATERTREE 2"X4" STAKES (36" LONG) BURIED BELOWFINISH GRADE - ENSURE STAKES ARE MARKEDTO SIGNIFY HAZARD IN LOCATIONS WITHHIGH PEDESTRIAN TRAFFICFINISH GRADEB&B OR CONTAINERIZED (REFER TO PLANTSCHEDULE)SCARIFY SIDES OF HOLE TO 4" DEPTH MINIMUMAMENDED PLANTING SOIL AS NEEDED PERSOIL ANALYSISCOMPACT PLANTING SOIL BENEATHROOTBALLNOTES:1.TREE STAKING OPTIONAL, HOWEVER, LANDSCAPE CONTRACTOR RESPONSIBLE FOR MAINTAINING TREES IN AN UPRIGHT (90 DEGREE/PERPENDICULAR) POSITION FOR 1 YEAR AFTER PLANTING IS COMPLETE OR UNTIL TREE ROOT SYSTEM IS FULLY ESTABLISHED AND STURDY.FINAL TREE STAKING DETAILS AND PLACEMENT TO BE APPROVED BY OWNER'S REPRESENTATIVE.2.CONTRACTOR SHALL ASSURE PERCOLATION OF ALL PLANTING PITS PRIOR TO INSTALLATION.3.IN SEMI-IMPERVIOUS SOIL CONDITIONS, ROOTBALL ELEVATION SHALL BE 2" ABOVE FINISH GRADE. COORDINATE WITH OWNER'SREPRESENTATIVE PRIOR TO SETTING ROOTBALL ELEVATIONS. 12" TYP. 12"MIN. DOUBLE SIZE OFROOTBALL, TYP. CLEAR TRUNK,REFER TO PLANTSCHEDULE COMPACTED SUBGRADE AMENDED PLANTING SOIL ASNEEDED PER SOIL ANALYSIS3" MINIMUM MULCH DEPTH,REFER TO PLANT SCHEDULE FORTYPEFINISH GRADESOIL BERM TO HOLD WATERMAINTAIN TREE IN A PLUMBUPRIGHT POSITION TRUNK OF PALMETTOS SHALL BENEARLY UNIFORM IN SIZE OVERENTIRE HEIGHT AND SHALL BEFREE OF OLD FROND STUBS, FIREBLACK AND OTHER DAMAGE REFOLIATED PALMETTO NOTES:1.FINAL TREE STAKING DETAILS AND PLACEMENT TO BE APPROVED BY OWNER OR OWNER'S REPRESENTATIVE,2.CONTRACTOR SHALL ASSURE PERCOLATION OF ALL PLANTING PITS PRIOR TO INSTALLATION.3.SABAL PALMETTOS SHALL BE REFOLIATED, PROTECT CABBAGE HEAD FROM DAMAGE. NOTES:1.WHEN GROUNDCOVERS AND SHRUBS ARE USED IS MASSES, ENTIRE BED TO BE EXCAVATED TO RECEIVE PLANTING SOIL ANDPLANT MATERIAL.2.CONTRACTOR SHALL ASSURE PERCOLATION OF ALL PLANTING PITS PRIOR TO INSTALLATION.3.IN SEMI-IMPERVIOUS SOIL CONDITIONS, ROOTBALL ELEVATION SHALL BE ±2" ABOVE FINISH GRADE. COORDINATE WITHOWNER'S REPRESENTATIVE PRIOR TO SETTING ROOTBALL ELEVATIONS. 4" TYP.DOUBLE SIZE OFROOTBALL, TYP.AMENDED PLANTING SOIL ASNEEDED PER SOIL ANALYSISB&B OR CONTAINERIZED (SEEPLANTING SCHEDULE, THIS SHEET)FINISH GRADESOIL BERM TO HOLD WATER3" MINIMUM MULCH DEPTH,REFER TO PLANT SCHEDULE FORTYPE --- SPECIFIED O.C. SPACINGNOTE:1.EXCAVATE ENTIRE BED SPECIFIED FORGROUNDCOVER PLANTING TO A DEPTHOF 12"TYPICAL EDGE OFPLANT BED1/2 OF SPECIFIED O.C.SPACINGSPECIFIED O.C.SPACINGATYPICAL SPACING INCURVILINEAR PLANT BEDS.OUTSIDE ROW TO FOLLOWCURVE AS SHOWN ON PLAN ±5' DIA.3" MINIMUM MULCH DEPTH, REFERTO PLANT SCHEDULE FOR TYPESMOOTH CONTINUOUSLY CUT EDGETYPICAL TREETREE STAKE NOTES:1.APPLY MULCH IN A ±5' DIAMETER WHEREPROPOSED TREE PLANTINGS OCCUR IN SODOR SEEDED AREAS. - 4 ' WTT Vt ' I I 1a%a" Allat !I[ell/Ee,Pe1[PB21$Ek11=1/~,40$pee-[1-I ,!J,/, .... .·.• ... ···•·· ·••· l#-1] I I l± 1} +##II I g;.,-.··· .. ·· = =llHj /4Nd) -ll-1ll,]bi?I / " NI­HATT tr>-II, I 7l-......::::::: ll II Hk± Hk± l ill1-...'.'·, -1 .· 1- LIE,L 111 ····. ··I·l···I·, ·>;.·.I,· •••ij == ff le=j id=_q@el±fjria;4[___][Litl' %l la-/[E1 ft]1-1·•.-,. .-_-. 1,.Tl ,[y + ] ItA 'II . ·• 1• :·-:_; ·+·- i V, C:0 z I O O Ht ~~ e%oz± 6 % 4 z 53 ~1 ' c = R I+ p -< er, 0r nV,l ' T 1 /\ '-' a '' ' A° A '\ T, < to' :) i%== r '< EOJ 3. ~ I a n t=; : OJ ! n jJ 1 "' zpl 0 3. a ri1' jJ G E 0%i] 1) I t , Ir } ti l I ' # I 7/ ] I 't ...., 4$ e --11 :) U < B5 OJ EV, >< 3::r z ~ 4tL a '< za a jJ4 r "' 3 • ' a 1) N 4 fh N Edi l j - • nO g ...., D'/\-:,jJ.., B5 b e f ashones»#; ..-""glandscape architecture 0land planning www.wjkltd.com 23 Promenade Street, Suite 201 W Bluttton, South Carolina # 29910 4 ph 843.757.7411 Page 56 of 68 1L600TABBY CONCRETE WITH BRICK BORDERSSCALE: 1" = 1'-0"2L600DETECTABLE PEDESTRIAN PAVINGSCALE: 3/4" = 1'-0" DRB ALTERATIONSUBMITTAL,NOT FORCONSTRUCTION DRAWING NUMBERDRAWING TITLE DESIGN CONCEPTS, DRAWING, SHEETS,LOGOS, SPECIFICATIONS, DETAILS,WRITTEN MATERIAL SHALL NOT BE USEDOR REPRODUCED IN WHOLE OR IN PARTIN ANY FORM WITHOUT PRIOR WRITTENCONSENT OF WJK LTD.© 2026 WJK LTD.THIS SHEET TO SCALE AT: 30"X42" DATE:PROJECT NO.:DRAWN BY:CHECKED BY:FEB 25, 202624095.01JCXX REVISIONS:SITE DEVELOPMENT PLANSFOR862 WILLIAM HILTON PARKWAYTOWN OF HILTON HEAD ISLAND, SOUTH CAROLINABEACH PROPERTIES BUILDING SITE DETAILSL600 A A' 2' MIN. /SIXCOURSESWIDE 6" OFF EDGE OF PAVEMENT, TYP.5'DETECTABLEWARNINGPAVER, TYP.ADJACENTMATERIAL VARIES,REFER TO PLAN,SHEET L100, TYP.ASPHALT, TYP.NOTES:1.SURFACES SHALL MEET THE GUIDELINES OFTHE A.D.A. STANDARDS FOR ACCESSIBILITY,APPENDIX A, PART 36.2.DETECTABLE WARNING PAVERS SHALL CONSISTOF RAISED TRUNCATED DOMES WITH ADIAMETER OF 0.9 INCHES (NOMINAL) A HEIGHTOF 0.2 INCHES (NOMINAL) AND A CENTERSPACING OF 2.35 INCHES (NOMINAL) ANDCOLOR SHALL CONTRAST WITH ADJOININGSURFACES. THE COLOR USED TO PROVIDECONTRAST SHALL BE AN INTEGRAL PART OFTHE WALKING SURFACE.3.PROVIDE 1% MIN., 2% MAX. CROSS SLOPE ONALL PAVED SURFACES FOR POSITIVE DRAINAGE.4.REFER TO PLAN (SHEET L100) FOR LOCATIONAND WIDTHS OF DETECTABLE WARNINGPAVERS.5.CONTRACTOR SHALL COORDINATE BORDERS,BANDING AND PATTERN WITH OWNER'SREPRESENTATIVE PRIOR TO CONSTRUCTION.6.CONSTRUCT EXPANSION JOINTS WHERE WALKMEETS CURBS, STEPS, WALLS OR FIXED SLABS.7.UPON REQUEST, CONTRACTOR SHALL PROVIDE4'X4' PAVING PANELS OF ALTERNATIVE COLORSPRIOR TO CONSTRUCTION FOR APPROVAL BYOWNER OR LANDSCAPE ARCHITECT. BRICK MANUFACTURER INFORMATION:MANUFACTURER: PINEHALLBRICK: ADA TRUNCATED DOME PAVERCOLOR: CHARCOALPATTERN: RUNNING BONDJOINTS: 3/8" IVORY BUFF COLOR, CONCAVEFINISHDETECTABLE WARNING PAVER, TYP.CONCRETE CURB - FLUSHWITH ROADWAY ATPEDESTRIAN ACCESS, TYP. EXISTING SUBGRADE PLAN SECTION FLUSH CONCRETECURB, TYP.ASPHALTPARKING, REFERTO ENGINEERSPLANS, TYP.ADJACENTMATERIAL VARIES,REFER TO PLAN,SHEETS L100 4"6"NOTES:1.PROVIDE 1% MIN., 2% MAX. CROSS SLOPEON ALL PAVED SURFACES FOR POSITIVEDRAINAGE.2.REFER TO PLAN (SHEET L100) FORWIDTHS OF WALK.3.CONSTRUCT EXPANSION JOINTS WHEREWALK MEETS CURBS, STEPS, WALLS ORFIXED SLABS.4.UPON REQUEST, CONTRACTOR SHALLPROVIDE 4'X4' SAMPLE OF CONCRETEWITH 2 SIZES OF OYSTER SHELL FINISHFOR APPROVAL BY OWNER ORLANDSCAPE ARCHITECT. TABBY SPEC:1.SHELL FINISH SHALL BE OYSTER SHELL MIX(EQUAL PARTS, SIZE #2, AND #3) HANDTHROWN / SPREAD TO 100% COVERAGEON FRESH POURED AND LEVELEDCONCRETE.2.HAND FLOAT UNTIL SHELL ISSUBMERGED, THEN AFTER 90% CURED,LIGHTLY PRESSURE WASH UNTIL SHELL ISEXPOSED. SECTION A-A'12"TABBY CONCRETE WALKWITH TURNDOWNSAND 6X6 10-10 W.W.M.FINISHED GRADECOMPACTEDSUBGRADEEXISTING SUBGRADEBRICK BORDER, TYP.MORTAR SETTING BEDPER MANUFACTURERSSPEC., TYP. BRICK MANUFACTURER INFORMATION:MANUFACTURER: PINEHALLBRICK: RUMBLED PAVERCOLOR: COCOA OR BLUFFS, TBDPATTERN: SINGLE HEADER COURSE BORDERJOINTS: 3/8" IVORY BUFFER COLOR,CONCAVE FINISHPLAN TABBY CONCRETEWALKEXPANSION JOINT, TYP.CONTROL JOINT, TYP.A A'WIDTH VARIES,TO BE COORDINATEDIN-FIELD BRICK BORDER, TYP.MORTAR JOINTS, TYP. CONCRETE INFORMATION:CONCRETE: 3,000 P.S.I. AT 28 DAYSFINISH: TABBY SHELL SOIL INFORMATION:SOIL COMPACTION: 95% STANDARDPROCTOR4" 45° CUT ATINTERSECTIONS, TYP., CUTALL BRICK FROM FULL,TYP. 3L600WASHOUT AREASCALE: NTS jif [I.[111 H R"°••e H IIII STRAWBALEBARRTERCONCRETEWASHOUT 10'MIN. aO l±B'11+[ ""'::E le o l.• H' >g+O oO NATIVE MATERIAL (OPTIONAL) /STAPLES 1/8" DIA. ~BINDINGWIRE 4"STAPLE n(2PERBALE) WOODOR\_STRAWBALE METALSTAKES (2PERBALE) SECTIONB-B STAKEt(TYP.) o o ··]··]··]·· .s TYPE"ABOVEGRADE"STRAWBALE WITHSTRAWBALES(TYP.) LETTERSA MINIMUMOF 5"IN HEIGH:lCONCRETE WASHOUT CONCRETEWASHOUTSIGNDETAIL NOTES 1.ACTUALLAYOUTDETERMINEDINFIELD. 2.INSTALLCONCRETEWASHOUTSIGN(24"X24",MINIMUM)WITHIN30'OFTHE TEMPORARYCONCRETEWASHOUTFACILITY. 3.TEMPORARYWASHOUTAREAMUSTBEATLEAST50'FROMASTORMDRAIN,CREEK BANKORPERIMETERCONTROL. 4.CLEANOUTCONCRETEWASHOUTAREAWHEN50%FULL. 5.THEKEYTOFUNCTIONALCONCRETEWASHOUTSISWEEKLYINSPECTIONS,ROUTINE MAINTENANCE,ANDREGULARCLEANOUT. 6.SILTFENCESHALLBEINSTALLEDAROUNDPERIMETEROFCONCRETEWASHOUTAREA EXCEPTFORTHESIDEUTILIZEDFORACCESSINGTHEWASHOUT. 7.AROCKCONSTRUCTIONENTRANCEMAYBENECESSARYALONGONESIDEOFTHE WASHOUTTOPROVIDEVEHICLEACCESS. CONCRETEWASHOUT STRAWBALESORABOVEGROUND SOUTHCAROLINADEPARTMENTOFPUBLICHEALTH STANDARDDRAWINGNO.RC-07[PAGEI] N.T.S. II Page 57 of 68 BEACH PROPERTIES OF HILTON HEAD 862 WILLIAM HILTON PKWY, HILTON HEAD, SOUTH CAROLINA, 29928 EXTERIOR RENOVATIONS TO EXTERIOR 01/26/2025 Page 58 of 68 BEACH PROPERTIES OF HILTON HEAD 862 WILLIAM HILTON PKWY, HILTON HEAD, SOUTH CAROLINA, 29928 EXTERIOR RENOVATIONS TO EXTERIOR 01/26/2025 ~F NE= Page 59 of 68 BEACH PROPERTIES OF HILTON HEAD 862 WILLIAM HILTON PKWY, HILTON HEAD, SOUTH CAROLINA, 29928 EXTERIOR RENOVATIONS TO EXTERIOR 01/26/2025 wipspsisdu.a • ~a'p2 ia I;+8e% " g@if@. ' ' • skis Page 60 of 68 BEACH PROPERTIES OF HILTON HEAD 862 WILLIAM HILTON PKWY, HILTON HEAD, SOUTH CAROLINA, 29928 EXTERIOR RENOVATIONS TO EXTERIOR 01/26/2025 Page 61 of 68 Standard Outdoor Locker System Parcel Pending by Quadient’s weatherproof outdoor locker systems are designed and engineered to withstand the elements in multiple package management applications that facilitate a seamless and convenient package delivery and collection process at multifamily properties. Parcel Pending parcel lockers make package management simple, freeing up time and space for both residents and property management. Locker system specifications • 18-gauge double-reinforced cold-rolled steel construction • Operational conditions: temperature -13° to +122° F - humidity up to 100% non-condensing • Rain, salt, and wind (category 3 cyclone) resistant • Control towers feature an industrial-grade touchscreen, a camera for photo capture, a keypad, a scanner supporting 1D and 2D barcode reading, and speakers • Camera and touchscreen are optimized for full functionality in bright sun, heat and cold conditions • Kiosk and screen are temperature controlled (air conditioning and heat) for operation in extreme conditions • Standard awnings provide users additional protection from outdoor elements and come with built-in lights. Short awnings are available as an option for D-series towers only • Each door features smart package sensors to detect packages and other items • Locker design is compliant with the Americans with Disabilities Act (ADA) - Every door size is available within the “reachable” range for wheelchair users, and control touchscreen and barcode scanner are also compliant for wheelchair accessibility • Cloud-based video surveillance is available as an option, with a camera that can be mounted on standard awnings • Lockers are certified for UL/CSA safety standards - UL/CSA 62368 and UL/CSA 60950 • Lockers are RoHS and REACH compliant Parcel Pending® and the Parcel Pending logo are registered trademarks of Parcel Pending. All other company and product names may be trademarks and are the property of their respective owners. All information in this document, including descriptions of features, functions, performance and specifications is subject to change without written notice at any time. ©2022 Parcel Pending. All Rights Reserved. April 2023 www.parcelpending.com | sales@parcelpending.com | (844) 657-4608 Custom colors or designs available as an option Brown Grey (RAL7013)Stone Grey (RAL7030) Jet Black (RAL9005) /// PARCEL PENDINGby Quadient Intertek •• Page 62 of 68 Towers specifications Parcel Pending® and the Parcel Pending logo are registered trademarks of Parcel Pending. All other company and product names may be trademarks and are the property of their respective owners. All information in this document, including descriptions of features, functions, performance and specifications is subject to change without written notice at any time. ©2022 Parcel Pending. All Rights Reserved. 04/19/2023 www.parcelpending.com | sales@parcelpending.com | (844) 657-4608 Standard Outdoor Locker System Tower measurements in inches without awning (W x D x H*) Tower measurements in inches with awning (W x D x H*) Tower measurements in inches with short awning (W x D x H*) D13, D6, D18, D12, D4, D1 39.5 x 24 x 79.7~80.5 39.5 x 42.4 x 86.3~87.1 39.5 x 28.3 x 82.9~83.7 S13, S6 22.5 x 24 x 79.7~80.5 22.5 x 42.4 x 86.3~87.1 n/a M23 27 x 24 x 79.7~80.5 27 x 42.4 x 86.3~87.1 n/a OS-3 53.7 x 24 x 79.7~80.5 53.7 x 42.4 x 86.3~87.1 n/a Total Doors (internal size in inches W x D x H) / (Max weight in lbs) D13 control tower D6 control tower D18 D12 S6 S13 M23 D4 D1 OS-3 Small (13.59 x 23.1 x 4.23) / (33) 7 1 12 11 Medium (13.59 x 23.1 x 9.25) / (33) 4 2 4 10 5 2 Large (13.59 x 23.1 x 24.33) / (44) 2 1 2 2 1 X-Large (13.59 x 23.1 x 36.85) / (44) 2 4 H-Small (7.39 x 23.1 x 4.23) / (33) 17 H-Medium (7.39 x 23.1 x 9.25) / (33) 6 Ultra (30.42 x 22.06 x 74.33) / (220) 1 OS-3 (44.9 x 22.4 x 24) / (220) 3 Weight with no awning (lbs) 434 357 403 360 203 295 388 309 278 419 Weight with standard awning (lbs) 485 408 454 410 231 324 421 359 329 485 Weight with short awning (lbs) 463 386 432 388 n/a n/a n/a 337 307 n/a * Includes slight adjustments to tower feet for balancing and leveling purposes. Page 63 of 68 Proposed Configuration W 93.5” D 24” H 87” including awning i D • • □L•- D Page 64 of 68 Page 65 of 68 1 DDEESSIIGGNN TTEEAAMM//DDRRBB CCOOMMMMEENNTT SSHHEEEETT TThhee ccoommmmeennttss bbeellooww aarree ssttaaffff rreeccoommmmeennddaattiioonnss ttoo tthhee DDeessiiggnn RReevviieeww BBooaarrdd ((DDRRBB)) aanndd ddoo NNOOTT ccoonnssttiittuuttee DDRRBB aapppprroovvaall oorr ddeenniiaall.. PROJECT NAME: 862 William Hilton Parkway DRB-000215-2026 DATE: 03/11/2026 CATEGORY: Alteration RECOMMENDATION: Approval Approval with Conditions Denial APPLICATION MATERIAL DRB REQUIREMENTS Complies Yes No Not Applicable Comments or Conditions Demolition Plan if needed Existing Conditions match As-Built Dimensioned Details and of Sections Detail Illustrating Connection to Existing Structure New Building Details Match Existing Building Details ARCHITECTURAL DESIGN DESIGN GUIDE/LMO CRITERIA Complies Yes No Not Applicable Comments or Conditions Structure is designed to be appropriate to the neighborhood Promotes pedestrian scale and circulation Design is unobtrusive and set into the natural environment Utilizes natural materials and colors Avoids distinctive vernacular styles Design is appropriate for its use All facades shall have equal design characteristics Page 66 of 68 2 Avoids monotonous planes or unrelieved repetition Has a strong roof form with enough variety to provide visual interest Overhangs are sufficient for the façade height. Forms and details are sufficient to reduce the mass of the structure Human scale is achieved by the use of proper proportions and architectural elements Utilizes a variety of materials, textures and colors Incorporates wood or wood simulating materials Windows are in proportion to the facade Details are clean, simple and appropriate while avoiding excessive ornamentation Utilities and equipment are concealed from view Decorative lighting is limited and low wattage and adds to the visual character Accessory elements are designed to coordinate with the primary structure LANDSCAPE DESIGN DESIGN GUIDE/LMO CRITERIA Complies Yes No Not Applicable Comments or Conditions Treats the Landscape as a major element of the project Provides Landscaping of a scope and size that is in proportion to the scale of the development Landscape is designed so that it may be maintained in its natural shape and size Preserves a variety of existing native trees and shrubs Provides for a harmonious setting for the site’s structures, parking areas or other construction Location of existing trees and new trees provides street buffers, mitigation for parking lots, and an architectural complement that visually mitigates between parking lots and building(s) Shrubs are selected to complement the natural setting, provide visual interest and screen less-desirable elements of the project A variety of species is selected for texture and color Provides overall order and continuity of the Landscape plan Page 67 of 68 3 Native plants or plants that have historically been prevalent on the Island are utilized A variety of sizes is selected to create a “layered” appearance for visual interest and a sense of depth The location of existing mature trees is taken into account in placement of shrubs so as not to damage tree roots Proper spacing and location for plants to reach their mature size and natural shape while avoiding excessive or unnatural pruning Proposed groundcovers are evergreen species with low maintenance needs Large, grassed lawn areas encompassing a major portion of the site are avoided The adjacent development is taken into account in determining the most appropriate buffer so as not to depart too dramatically from the neighborhood Ornamentals and Annuals are limited to entrances and other focal points NATURAL RESOURCE PROTECTION DESIGN GUIDE/LMO CRITERIA Complies Yes No Not Applicable Comments or Conditions An effort has been made to preserve existing trees and under story plants Supplemental and replacement trees meet LMO requirements for size, species and number Wetlands if present are avoided and the required buffers are maintained Sand dunes if present are not disturbed COMMENTS & CONDITIONS Staff recommend approval of the Final submittal for 862 William Hilton Parkway, with the following conditions: 1. Any additional information as required by the Board. Page 68 of 68

Source: Town of Hilton Head Island website. First collected Oct 17, 2026.