_09242026-589
City of North Myrtle Beach · Horry County · meeting of Sep 24, 2026 · Minutes
Open the original document More from City of North Myrtle Beach
Text
Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.
TRC Minutes 09.24.26 Page 1 of 2
TECHNICAL REVIEW COMMITTEE MINUTES
Thursday, September 24, 2026 – 10:00 A.M.
Training Room/Zoom
NEW APPLICATIONS
CR-26-47: Courtesy Review – Join 2706 South Ocean Boulevard to 2712 Perrin Drive
Attending
Customer
Representatives:
Ashley Baldes, Applicant
Staff Comments
Public Works: 1. Need site plan for review.
2. Driveway placement/spacing subject to review.
3. Parking area subject to review.
Zoning: 4. Need proposed floorplan.
5. Need survey of 2712 Perrin for permitting.
6. Need scaled drawing for proposed plot plan.
Building: 7. Architectural and engineering plans are required for combining the structures.
Fire: No comments
Planning: 8. Need site plan for review.
SUB-26-50: Major Preliminary Subdivision Plat – Barefoot Lakes off Marsh Glen Drive
Attending
Customer
Representatives:
Spencer Harrelson, Engineer
Staff Comments
Public Works: 1. Comments pending.
Zoning: 2. Street tree planting plan and 8’ hedgerow plan requested.
Building: 3. See Fire Marshall comment.
Fire: 4. Based on the proposed occupancy/load, additional fire protection systems (e.g.,
sprinklers, fire alarm) may be required. Revise plans to demonstrate compliance
with applicable code provisions.
5. Due to number of dwelling units the trade off for one access/egress requires
each dwelling to be fire sprinklered per NFPA 13D
Planning: 6. This project requires Major Sketch Plan approval. Can be reviewed concurrently
with this project and presented to PC at the same time. Please refer to The
Anchors Bay arborist report from the 9/22 PC meeting as a reference.
7. Show EOP on plat.
8. Provide a landscape plan that includes plantings, buffers, and compliance with
applicable zoning requirements.
9. Street trees are required to be native species per City standards.
10. Per the Fire Marshal's note, please add: In addition, all Residential Units within
the Property shall be protected from fire by the installation of internal sprinkler
systems, in accordance with the requirements for residential sprinkler systems
within the City (the "Required Sprinkler Systems"), which systems are required
TRC Minutes 09.24.26 Page 2 of 2
in lieu of the installation of a secondary access entry to the Property. The City
may withhold building permits for any Residential Unit which does not include
the Required Sprinkler Systems.
11. This item will require Planning Commission review prior to approval.
SUB-26-53: Major Final Subdivision Plat – Marshfield Phase 3
Attending
Customer
Representatives:
Spencer Harrelson, Engineer
Staff Comments
Public Works: No comments
Zoning: No comments
Building: No comments
Fire: No comments
Planning: 1. C23 is used twice on the plat and represented once on the curve table.
2. C24 is used twice on the plat and represented once on the curve table.
3. No C8 on the curve table.
4. No C9 on the curve table.
5. 347-05-03-0005 showed as 347-05-03-0020 when I checked the land records.
6. Double check DB 4271/881.
7. DB 2890/1130 can be updated to DB 2890/1133 to represent the most recent
deed.
8. Additional comments regarding FG in separate step.
Source: City of North Myrtle Beach website. First collected Oct 17, 2026.