Planning Commission: Maybank Concept Plan Set
City of Charleston · Berkeley County · meeting of Oct 21, 2026 · Agendas
Open the original document More from City of Charleston
Text
Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.
SHEET NUMBERPROJECT:
TITLE:
No. DATEBY
Drawing name: K:\CHA_LDEV\018278 Cooper Law Firm\100 Maybank PUD\02 - DWG\PlanSheets\C0-00 - COVER SHEET.dwg C0-00 COVER SHEET Aug 19, 2026 11:27am by: Devin.FrankThis document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose and client for which it was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Kimley-Horn and Associates, Inc. shall be without liability to Kimley-Horn and Associates, Inc.
PRELIMINARY: NOT FOR CONSTRUCTION
© 2026 KIMLEY-HORN AND ASSOCIATES, INC.1080 MORRISON DRIVE, SUITE 240CHARLESTON, SOUTH CAROLINA 29403PHONE (843) 737-6390WWW.KIMLEY-HORN.COM
CLIENT:
CERTIFICATE OF AUTHORIZATIONAND
No. C00166INC
KIMLEY-HORNASSOCIATES,
TUSO NILAHCROA
PRELIMINARYNOT FOR CONSTRUCTION
REVISIONS0ISSUED FOR PERMIT REVIEW12-12-2025KHA1ISSUED FOR PERMIT REVIEWKHA2ISSUED FOR PERMIT REVIEWKHA3ISSUED FOR PERMIT REVIEWKHA05-11-202606-29-202608-18-2026COOPER LAW FIRM474 WANDO PARK BLVD,SUITE 105MT. PLEASANT, SC 29464PHONE: 843.881.5413
MAYBANK SUBDIVISIONCONCEPT PLANMAYBANK HIGHWAY, JOHNS ISLAND, SC 29455
SCALE:DRAWN BY:DESIGNED BY:CHECKED BY:
AS SHOWN
QRDGCC
KHA
KHA PROJECT NO.01827810002/09/2026DATE:
CIVIL CONCEPTUAL CONSTRUCTION DRAWINGS FORMAYBANK SUBDIVISION CONCEPT PLANMAYBANK HIGHWAY, JOHNS ISLAND, SC 29455CITY PUD ID # PUD2026-000033
PARCEL NO.: 2790000017, -008, -009, -010, -288, 3130000047, -237, -006CURRENT ZONING: TMS #2790000288: RR-1 (RURAL RESIDENTIAL)TMS #2790000008: RR-1 (RURAL RESIDENTIAL)TMS #2790000009: RR-1 (RURAL RESIDENTIAL)TMS #2790000010: RR-1 (RURAL RESIDENTIAL)TMS #2790000017: RR-1 (RURAL RESIDENTIAL)TMS #3130000047: RR-1 (RURAL RESIDENTIAL)TMS #3130000237: RR-1 (RURAL RESIDENTIAL)TMS #3130000006: GB (GENERAL BUSINESS)PROPOSED ZONING: PUD (PLANNED UNIT DEVELOPMENT)JOHNS ISLAND, CITY OF CHARLESTON, SOUTH CAROLINA GROSS PUD SITE AREA = 15.61 ACRESCOMMERCIAL DISTRICT = 2.29 ACRES RESIDENTIAL DISTRICT = 13.32 ACRESPROJECT PROPERTY AREA = 13.47 ACRESWETLAND AREA = 1.60 ACRESUPLAND AREA = 11.87 ACRESOPEN SPACE AREA: 4.91 ACRES
PROJECT CONTACTSOWNER/DEVELOPER: COOPER LAW FIRM, LLC474 WANDO PARK BLVD, SUITE 105MOUNT PLEASANT, SC 29464PHONE: (843) 881-5413CONTACT: RANDOLPH W. COOPER, ESQUIREEMAIL: RANDY@RCOOPERLAW.ORGCIVIL ENGINEER/KIMLEY-HORN & ASSOCIATES, INC.LANDSCAPE ARCHITECT:1080 MORRISON DRIVE, SUITE 240CHARLESTON, SC 29403PHONE: (843) 779-1621CIVIL CONTACT: PRESTON ACKERMANEMAIL: PRESTON.ACKERMAN@KIMLEY-HORN.COMLANDSCAPE CONTACT: ANDREW TODD-BURKEEMAIL: ANDREW.TODD-BURKE@KIMLEY-HORN.COMSURVEYOR: HLA, INC.29A LEINBACH DRIVECHARLESTON SOUTH CAROLINA, 29407PHONE: (843) 763-1166 CONTACT: RICHARD LACEY, P.L.S.EMAIL: RLACEY@HLAINC.COM
NOTES:1.ATTENTION IS DRAWN TO THE FACT THAT THE SCALE OF THESE DRAWINGS MAY HAVE BEEN DISTORTEDDURING THE REPRODUCTION PROCESS. THIS DOCUMENT, TOGETHER WITH THE CONCEPTS ANDDESIGNS PRESENTED HEREIN, AS AN INSTRUMENT OF SERVICE, IS INTENDED ONLY FOR THE SPECIFICPURPOSE AND CLIENT FOR WHICH IT WAS PREPARED. REUSE OF AND IMPROPER RELIANCE ON THISDOCUMENT WITHOUT WRITTEN AUTHORIZATION AND ADAPTATION BY KIMLEY-HORN AND ASSOCIATES,INC. SHALL BE WITHOUT LIABILITY TO KIMLEY-HORN AND ASSOCIATES, INC.2.IF ANY CONFLICTS, DISCREPANCIES, OR ANY OTHER UNSATISFACTORY CONDITIONS ARE DISCOVERED,EITHER ON THE CONSTRUCTION DOCUMENTS OR FIELD CONDITIONS, THE MUST NOTIFYTHE ENGINEER IMMEDIATELY AND SHALL NOT COMMENCE FURTHER OPERATION UNTIL THE CONFLICTS,DISCREPANCIES, OR OTHER UNSATISFACTORY CONDITIONS ARE RESOLVED.3.THE APPROVAL OF THESE PLANS AND THE ISSUANCE OF THIS LAND DISTURBANCE PERMIT DOES NOT INANY WAY SUGGEST THAT ALL OTHER REQUIREMENTS FOR THE LEGAL OR APPROPRIATE OPERATIONSFOR THIS ACTIVITY, WHICH MAY REQUIRE ADDITIONAL PERMITTING HAVE BEEN MET. THE ONUS IS ON THEOWNER/DEVELOPER/ BUILDER TO DISCOVER WHAT ADDITIONAL PERMITTING OR APPROVALS MAY BENECESSARY TO OPERATE FROM THIS POINT IN AN APPROPRIATE AND LEGAL MANNER. PLAN APPROVALOR PERMIT ISSUANCE DOES NOT ABSOLVE THE APPLICANT FROM COMPLYING WITH ALL APPLICABLELAWS, STANDARDS, OR OTHER PERMITS WHICH MAY BE REQUIRED FOR THIS PROJECT.
THE PROJECT SITE DOES NOT LIE WITHIN A FLOOD HAZARD AREA PER FIRMPANEL 45019C0655K DATED 01/29/2021.
PROJECT SITEPROJECT SITE
VICINITY MAP
NORTHFEMA MAP
C0-00
COVER SHEET
N.T.S.
MAYBANK HIGHWAY
FERN HILL ROAD
PURPOSE:MAYBANK SUBDIVISION DEVELOPMENT IS DESIGNED TO ADVANCE THE GOALS OF THE CHARLESTON CITYPLAN, PARTICULARLY ITS EMPHASIS ON CREATING A CONNECTED, INCLUSIVE, AND RESILIENT COMMUNITY.THE DEVELOPMENT SUPPORTS A MIX OF HOUSING TYPES THAT ALIGN WITH THE CITY’S FUTURE LAND USEDESIGNATIONS AND HOUSING AFFORDABILITY STRATEGIES. IN KEEPING WITH THE RESILIENCE AND EQUITYFRAMEWORK OF THE CITY PLAN, THE DEVELOPMENT PROMOTES EQUITABLE ACCESS TO HOUSING,TRANSPORTATION, AND GREEN SPACE, WHILE PRESERVING THE NATURAL CHARACTER OF JOHNS ISLANDWITHIN THE URBAN GROWTH BOUNDARY
Sheet List TableDrawing Revision NumberSheet TitleSheet Number3 COVER SHEETC0-00GENERAL NOTESC0-01SURVEY (BY OTHERS)--SURVEY (PAGE 1)--SURVEY (PAGE 2)--SURVEY (PAGE 3)--SURVEY (PAGE 4)--EXISTING CONDITIONS PLANC1-003 SITE PLANC2-003 ROAD CROSS SECTIONSC2-013 OPEN SPACEC2-103 ACCESSIBLE ROUTE PLANC2-153 FIRE PROTECTION PLANC2-303 GRADING AND DRAINAGE PLANC3-003 UTILITY PLANC4-00
SHEET NUMBERPROJECT:
TITLE:
No. DATEBY
Drawing name: K:\CHA_LDEV\018278 Cooper Law Firm\100 Maybank PUD\02 - DWG\PlanSheets\C0-00 - COVER SHEET.dwg C0-01 GENERAL NOTES Aug 19, 2026 11:27am by: Devin.FrankThis document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose and client for which it was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Kimley-Horn and Associates, Inc. shall be without liability to Kimley-Horn and Associates, Inc.
PRELIMINARY: NOT FOR CONSTRUCTION
© 2026 KIMLEY-HORN AND ASSOCIATES, INC.1080 MORRISON DRIVE, SUITE 240CHARLESTON, SOUTH CAROLINA 29403PHONE (843) 737-6390WWW.KIMLEY-HORN.COM
CLIENT:
CERTIFICATE OF AUTHORIZATIONAND
No. C00166INC
KIMLEY-HORNASSOCIATES,
TUSO NILAHCROA
PRELIMINARYNOT FOR CONSTRUCTION
REVISIONS0ISSUED FOR PERMIT REVIEW12-12-2025KHA1ISSUED FOR PERMIT REVIEWKHA2ISSUED FOR PERMIT REVIEWKHA3ISSUED FOR PERMIT REVIEWKHA05-11-202606-29-202608-18-2026COOPER LAW FIRM474 WANDO PARK BLVD,SUITE 105MT. PLEASANT, SC 29464PHONE: 843.881.5413
MAYBANK SUBDIVISIONCONCEPT PLANMAYBANK HIGHWAY, JOHNS ISLAND, SC 29455
SCALE:DRAWN BY:DESIGNED BY:CHECKED BY:
AS SHOWN
QRDGCC
KHA
KHA PROJECT NO.01827810002/09/2026DATE:
C0-01
GENERAL NOTES
1.REFER TO MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (LATEST EDITION) AND SCDOT STANDARDS FOR DETAILSOF STANDARD TRAFFIC CONTROL SIGNS AND STANDARDS.
GENERAL NOTES:
TREE PROTECTION NOTES:
TRAFFIC CONTROL:
UTILITY NOTES:
DRAINAGE:
BACKFLOW PREVENTION NOTES:
1.STRUCTURAL AND SUBSURFACE DRAINAGE DESIGN FOR RETAINING WALLS ARE NOT ADDRESSED IN CIVIL PLANS BYKIMLEY-HORN AND ASSOCIATES.2.BOTTOM OF WALL ("BG") GRADES SHOWN ON THESE PLANS REPRESENT FINISHED GROUND ADJACENT TO WALL. TOP OFWALL ("TG") ELEVATIONS ASSUME FINISHED GROUND ADJACENT TO WALL. REFER TO RETAINING WALL PLANS (BYOTHERS) FOR ALL TG AND BG ELEVATIONS, DRAINAGE AND CONSTRUCTION METHODS.3.RETAINING WALLS WITH ELEVATION DROP EXCEEDING 2'-6" IN HEIGHT SHALL HAVE GUARDRAILS OR FENCING FOR FALLPROTECTION.
1.CONTRACTOR SHALL REFER TO ARCHITECTURAL PLANS FOR PRECISE BUILDING DIMENSIONS, BUILDING UTILITYENTRANCE LOCATIONS, AND EXACT LOCATIONS AND DIMENSIONS OF EXIT PORCHES, RAMPS, DOWNSPOUTS, GRAVELAREAS ADJACENT TO BUILDING WALLS, UTILITY ENTRANCE LOCATIONS AND BOLLARDS IN BUILDING SIDEWALKS. ANYDISCREPANCIES FOUND BETWEEN THE BUILDING AND CIVIL PLANS SHALL BE IMMEDIATELY REPORTED TO THEENGINEER.2.ACCESSIBLE PARKING SIGNS WITH A "VAN" MARKING SHALL HAVE ADDITIONAL SIGN MOUNTED BELOW THE SYMBOL OFACCESSIBILITY SIGN DENOTING VAN ACCESSIBILITY; REFER TO CONSTRUCTION DETAIL SHEETS.3.REFER TO CONSTRUCTION DETAIL SHEETS FOR DETAILS OF ON-SITE SIGNAGE, STRIPING, AND PAVEMENT MARKING.REFER TO SITE PLAN FOR ADDITIONAL DIMENSIONAL INFORMATION.4.ALL WORK AND MATERIALS SHALL COMPLY WITH ALL CITY, COUNTY AND STATE REGULATIONS AND CODES AND O.S.H.A.STANDARDS.5.ALL ISLANDS WITH CURB SHALL BE LANDSCAPED UNLESS OTHERWISE INDICATED.6.EXISTING CONDITIONS SHOWN HEREON ARE FROM A SURVEY FILE PROVIDED BY HLA. DATED 05/09/2025.7.THE CONTRACTOR SHALL EMPLOY ALL NECESSARY BARRICADES, SIGNS, FENCES, FLASHING LIGHTS, TRAFFIC MEN, ETC.FOR MAINTENANCE AND PROTECTION OF TRAFFIC AS REQUIRED BY THE STATE DEPT. OF TRANSPORTATION, AND CITYOF CHARLESTON INSPECTIONS.8.THE CONTRACTOR SHALL PROTECT ALL MONUMENTS, IRON PINS, AND PROPERTY CORNERS DURING CONSTRUCTION.9.THE CONTRACTOR SHALL REPLACE EXISTING CONCRETE CURBS, SIDEWALK, PAVING, AND GUTTER AS INDICATED ONPLANS AND AS NECESSARY TO CONNECT TO EXISTING INFRASTRUCTURE.10.APPROVAL OF THIS PLAN IS NOT AN AUTHORIZATION TO GRADE ADJACENT PROPERTIES. WHEN FIELD CONDITIONSWARRANT OFF-SITE GRADING, PERMISSION MUST BE OBTAINED FROM THE AFFECTED PROPERTY OWNERS ANDTEMPORARY CONSTRUCTION EASEMENTS MAY BE REQUIRED.11.CONTRACTOR AGREES TO REPAIR ANY DAMAGE TO THE PUBLIC RIGHT-OF-WAY IN ACCORDANCE WITH THE STANDARDSOF SCDOT AND CITY OF CHARLESTON.12.COORDINATE ALL CURB AND STREET GRADES IN INTERSECTIONS WITH INSPECTOR.13.THE CONTRACTOR SHALL IMMEDIATELY REPORT TO THE OWNER ANY DISCREPANCIES FOUND BETWEEN THE ACTUALFIELD CONDITIONS AND THE CONSTRUCTION DOCUMENTS AND SHALL WAIT FOR INSTRUCTION PRIOR TO PROCEEDING.14.ALL SITE DIMENSIONS ARE REFERENCED TO THE FACE OF CURB OR EDGE OF PAVEMENT UNLESS OTHERWISE NOTED.ALL BUILDING DIMENSIONS ARE REFERENCED TO THE OUTSIDE FACE OF THE STRUCTURE.15.THE CONTRACTOR SHALL CONSTRUCT ACCESSIBLE RAMPS AT ALL INTERSECTIONS IN ACCORDANCE WITH SCDOT ANDCITY OF CHARLESTON STANDARDS.16.SIGHT TRIANGLES SHOWN ARE THE MINIMUM REQUIRED.17.ALL OFF-SITE CONSTRUCTION MUST BE PERFORMED IN ACCORDANCE WITH CURRENT SCDOT STANDARDSPECIFICATIONS AND DETAILS. ALL ON-SITE CONSTRUCTION MUST BE PERFORMED IN ACCORDANCE WITH CITY OFCHARLESTON STANDARD SPECIFICATIONS AND DETAILS.18.ALL WORK MUST COMPLY WITH SOUTH CAROLINA STATE BUILDING CODE AND SOUTH CAROLINA ACCESSIBILITY CODE ASWELL AS FEDERAL, STATE AND LOCAL ACCESSIBILITY REQUIREMENTS.19.ADJACENT STREETS SHALL BE KEPT CLEAN AT ALL TIMES.20.CONTRACTOR SHALL FOLLOW ALL RECOMMENDATIONS FROM THE PROJECT GEOTECH REPORT PREPARED BY ECSSOUTHEAST, LLC DATED 04/21/2026.
1.THE CONTRACTOR SHALL PROTECT ALL TREES AND SHRUBS OUTSIDE OF CUT/FILL LINES, IN ADDITION TO THOSE THATRECEIVE TREE/SHRUB PROTECTION BARRIERS. THE CONTRACTOR IS ALSO REQUESTED TO SAVE ALL OTHER EXISTINGTREES AND SHRUBS WHERE POSSIBLE.2.WHEN ROOT PRUNING IS NECESSARY, CUT ROOTS CLEANLY USING A DISC TRENCHER AND IMMEDIATELY COVER ALLROOT CUT SURFACES LARGER THAN TWO INCHES IN DIAMETER WITH TREE WOUND DRESSING. USE PLYWOOD FORMSWHEN TREE ROOTS ARE ADJACENT TO PROPOSED CURB & GUTTER OR SIDEWALK.3.NO SOIL DISTURBANCE OR COMPACTION, CONSTRUCTION MATERIALS, TRAFFIC, BURIAL PITS, TRENCHING OR OTHERLAND DISTURBING ACTIVITY ALLOWED IN THE TREE PROTECTION ZONE. TREE BARRICADES MUST BE INSTALLED BEFOREANY DEMOLITION, GRADING OR CONSTRUCTION BEGINS, AND NOT REMOVED UNTIL FINAL INSPECTION.4.NO GRUBBING WITHIN TREE PROTECTION ZONE. LEAVE SOIL AND LEAF LITTER UNDISTURBED. SUPPLEMENT WITH 1-2INCHES OF MULCH. RE-SEED WITH GRASS ONLY IN DISTURBED/GRADED AREAS.5.TREE BARRICADES MUST BE INSTALLED BEFORE ANY DEMOLITION, CLEARING, GRADING OR CONSTRUCTION BEGINSAND IS NOT TO BE REMOVED UNTIL AFTER CONSTRUCTION.
1.STORM PIPE SHALL BE AS FOLLOWS UNLESS OTHERWISE NOTED:15" DIAMETER AND LARGER: RCP, CLASS III PER ASTM C-76, WITH FLEXIBLE PLASTIC BITUMEN GASKETS AT JOINTS.LESS THAN 15" DIAMETER: PVC SCHEDULE 40 OR HDPE - AASHTO DESIGNATION M252 TYPE S, M294 TYPE S ANDMP7-97 TYPE S, SMOOTH INTERIOR/ANNULAR EXTERIOR. ONLY PERMITTED WHEN SPECIFICALLY INDICATED ONTHE CONSTRUCTION DRAWINGS. PIPE SHALL BE INSTALLED IN ACCORDANCE WITH PIPE MANUFACTURER'SINSTALLATION GUIDELINES OR SCDOT SPECIFICATION, WHICHEVER IS MORE STRINGENT. PIPE JOINTS ANDFITTINGS SHALL CONFORM TO AASHTO M252 AND M294.2.ALL STORM DRAINAGE WITHIN THE PUBLIC RIGHT-OF-WAY SHALL BE CLASS III REINFORCED CONCRETE PIPE UNLESSOTHERWISE SPECIFIED AS CLASS IV.3.ALL PIPE LENGTHS AND SLOPES ARE APPROXIMATE.4.ALL PIPES SHALL BE LAID ON STRAIGHT ALIGNMENTS AND EVEN GRADES USING A PIPE LASER OR OTHER ACCURATEMETHOD.5.ADDITIONAL SUBSURFACE DRAINAGE MAY RE REQUIRED IN THE STREET RIGHT-OF-WAY IF DEEMED NECESSARY BY THEINSPECTOR.6.UNDERGROUND UTILITY LINES SHALL BE INSTALLED IN ACCORDANCE WITH THE FOLLOWING STANDARDS IN ADDITION TOOTHER APPLICABLE CRITERIA:A.NO MORE THAN 500 LF OF TRENCH MAY BE OPENED AT ONE TIME.B.EXCAVATED MATERIAL SHALL BE PLACED ON THE UPHILL SIDE OF TRENCHES.C.EFFLUENT FROM DEWATERING OPERATIONS SHALL BE FILTERED OR PASSED THROUGH AN APPROVEDSEDIMENT TRAPPING DEVICE, OR BOTH, AND DISCHARGED IN A MANNER THAT DOES NOT ADVERSELY AFFECTFLOWING STREAMS OR OFF-SITE PROPERTY.D.MATERIAL USED FOR BACK-FILLING TRENCHES SHALL BE PROPERLY COMPACTED IN ORDER TO MINIMIZEEROSION AND PROMOTE STABILIZATION.E.DESTABILIZATION SHALL BE ACCOMPLISHED IN ACCORDANCE WITH THE EROSION AND SEDIMENT CONTROL REGULATIONS.F.APPLICABLE SAFETY REGULATIONS SHALL BE COMPLIED WITH.7.IF ANY EXISTING STRUCTURES TO REMAIN ARE DAMAGED DURING CONSTRUCTION, IT SHALL BE THE CONTRACTORSRESPONSIBILITY TO REPAIR AND/OR REPLACE THE EXISTING STRUCTURE AS NECESSARY TO RETURN IT TO EXISTINGCONDITIONS OR BETTER.8.ALL STORM PIPE ENTERING STRUCTURES SHALL BE GROUTED TO ASSURE CONNECTION AT STRUCTURE IS WATERTIGHT.9.ALL STORM STRUCTURES SHALL HAVE A SMOOTH UNIFORM POURED MORTAR INVERT FROM INVERT IN TO INVERT OUT.10.PRECAST STRUCTURES MAY BE USED AT CONTRACTORS OPTION. CATCH BASINS, MANHOLES, FRAMES, GRATES, ETC.SHALL MEET THE REQUIREMENTS OF THE LATEST EDITION OF THE SCDOT STANDARD DETAILS AND SPECIFICATIONS.11.THIS PLAN DETAILS PIPES UP TO 5FT FROM THE BUILDING FACE. REFER TO DRAWINGS BY OTHERS FOR BUILDINGCONNECTIONS. CONTRACTOR SHALL SUPPLY AND INSTALL PIPE ADAPTERS AS NECESSARY.12.ALL STORM SEWER MANHOLES IN PAVED AND UNPAVED AREAS SHALL BE FLUSH WITH PAVEMENT, AND SHALL HAVETRAFFIC BEARING RING & COVERS. LIDS SHALL BE LABELED "STORM SEWER".13.STRUCTURE TOP ELEVATIONS SHOWN HERE IN ARE APPROXIMATE. CONTRACTOR SHALL ADJUST AS NECESSARY.14.RIM ELEVATIONS AS SHOWN ON THE CONSTRUCTION DRAWINGS ARE TO THE GUTTER FLOW LINE.15.DRAINAGE AS-BUILTS WILL BE REQUIRED FOR FINAL INSPECTION.16.ALL STORM CONNECTIONS SHALL BE WATERTIGHT.
1.ALL FILL MATERIAL IS TO BE IN PLACE, AND COMPACTED BEFORE INSTALLATION OF PROPOSED UTILITIES.2.CONTRACTOR SHALL NOTIFY THE ST. JOHNS WATER UTILITY INSPECTORS 72-HOURS BEFORE CONNECTING TO ANYEXISTING WATER LINE. CONTRACTOR SHALL NOTIFY THE CHARLESTON WATER SYSTEM UTILITY INSPECTORS 72-HOURSBEFORE CONNECTING TO ANY EXISTING SEWER LINE.3.SANITARY SEWER PIPE SHALL BE AS FOLLOWS:8" PVC SDR35 PER ASTM D 3034, FOR PIPES LESS THAN 12' DEEP8" PVC SDR26 PER ASTM D 3034, FOR PIPES MORE THAN 12' DEEP 6" PVC SCHEDULE 404" PVC SCHEDULE 40DUCTILE IRON PIPE PER AWWA C150 AND AWWA C1514.WATER LINES SHALL BE AS FOLLOWS:4" AND LARGER - DUCTILE IRON PIPE PER AWWA C150SMALLER THAN 4" - TYPE K COPPER TUBE5.MINIMUM TRENCH WIDTH SHALL BE 3 FEET.6.ALL WATER JOINTS ARE TO BE MECHANICAL JOINTS WITH THRUST BLOCKING AS CALLED OUT ON UTILITY DETAILS.7.WATER AND SEWER MAINS SHALL BE KEPT TEN (10') APART (PARALLEL) OR WHEN CROSSING 18" VERTICAL CLEARANCE(OUTSIDE EDGE OF PIPE TO OUTSIDE EDGE OF PIPE).8.CONTRACTOR SHALL MAINTAIN A MINIMUM OF 3.0' COVER ON ALL WATERLINES.9.IN THE EVENT OF A VERTICAL CONFLICT BETWEEN WATERLINES, SANITARY LINES, STORM LINES AND GAS LINES(EXISTING AND PROPOSED), THE SANITARY LINE SHALL BE DUCTILE IRON PIPE WITH MECHANICAL JOINTS AT LEAST 10FEET ON BOTH SIDES OF CROSSING, THE WATERLINE SHALL HAVE MECHANICAL JOINTS WITH APPROPRIATE THRUSTBLOCKING, MEETING REQUIREMENTS OF ANSI A21.10 OR ANSI 21.11 (AWWA C-151) (CLASS 50).10.LINES UNDERGROUND SHALL BE INSTALLED, INSPECTED AND APPROVED BEFORE BACKFILLING.11.ALL CONCRETE FOR ENCASEMENTS SHALL HAVE A MINIMUM 28 DAY COMPRESSION STRENGTH AT 3000 P.S.I.12.THE AUTHORITY HAVE JURISDICTION HAS THE RIGHT TO INSPECT ALL PRIVATE WATER SYSTEMS.13.DRAWINGS DO NOT PURPORT TO SHOW ALL EXISTING UTILITIES.14.EXISTING UTILITIES SHALL BE VERIFIED IN FIELD PRIOR TO INSTALLATION OF ANY NEW LINES.15.REFER TO ARCHITECTURAL DRAWINGS FOR TIE-IN LOCATION AND ELEVATION OF ALL UTILITIES.16.CONTRACTOR IS RESPONSIBLE FOR COMPLYING TO THE SPECIFICATIONS OF ST. JOHNS WATER WITH REGARD TOMATERIALS, INSTALLATION, AND TESTING OF THE WATER LINES. CONTRACTOR IS RESPONSIBLE FOR COMPLYING TO THESPECIFICATIONS OF CHARLESTON WATER SYSTEM WITH REGARD TO MATERIALS, INSTALLATION, AND TESTING OF THESEWER LINES.17.THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND/OR ELEVATION OF EXISTING UTILITIES ASSHOWN ON THESE PLANS IS BASED ON RECORDS OF THE VARIOUS UTILITY COMPANIES, AND WHERE POSSIBLE,MEASUREMENTS TAKEN IN THE FIELD. THE INFORMATION IS NOT TO BE RELIED ON AS BEING EXACT OR COMPLETE. THECONTRACTOR MUST CALL THE APPROPRIATE UTILITY COMPANIES AT LEAST 72 HOURS BEFORE ANY EXCAVATION TOREQUEST EXACT FIELD LOCATION OF UTILITIES.18.IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO RELOCATE ALL EXISTING UTILITIES CHARTED ORUNCHARTED WHICH CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THE PLANS.19.ALL NECESSARY INSPECTIONS AND/OR CERTIFICATIONS AND/OR TESTING REQUIRED BY CODES AND/OR UTILITYSERVICE COMPANIES SHALL BE PERFORMED PRIOR TO ANNOUNCED BUILDING POSSESSION AND THE FINALCONNECTION OF SERVICE.20.CONTRACTOR SHALL COORDINATE WITH ALL UTILITY COMPANIES FOR INSTALLATION REQUIREMENTS ANDSPECIFICATIONS.21.ALL UTILITY MAIN LENGTHS SHOWN ARE APPROXIMATE.22.ALL EXISTING UTILITIES PROPOSED TO BE RELOCATED ON THESE PLANS SHALL BE PLACED UNDERGROUND.23.ALL SANITARY SEWER AND WATER DISTRIBUTION SYSTEM WORK TO BE INSTALLED BY A LICENSED UTILITYCONTRACTOR.24.THE CONTRACTOR SHALL COORDINATE AS REQUIRED WITH THE UTILITY PROVIDER FOR INSTALLATION OF PRIMARYELECTRIC SERVICE AND TELEPHONE SERVICE TO THE PROPOSED BUILDINGS.25.WHEN A WATER MAIN CROSSES OVER A SEWER MAIN, THERE MUST BE EIGHTEEN INCHES OF VERTICAL SEPARATION. IFTHE WATER MAIN MUST GO UNDER THE SEWER MAIN, BOTH THESE LINES MUST BE OF DUCTILE IRON FOR A DISTANCEOF TEN FEET ON EITHER SIDE OF THE CROSSING WITH A TWELVE INCH VERTICAL SEPARATION. THE CROSSING OFOTHER UNDERGROUND PIPE REQUIRES A MINIMUM OF TWELVE INCHES OF VERTICAL SEPARATION. ALL DISTANCES AREMEASURED FROM OUTSIDE DIAMETER TO OUTSIDE DIAMETER.26.WHEN A WATER LINE PASSES OVER OR UNDER A STORM SEWER, VERTICAL SEPARATION OF 18 INCHES SHALL BEMAINTAINED UNLESS WATER LINES ARE OF DUCTILE IRON OR ENCASED IN CONCRETE. A MINIMUM 6" CONCRETE PADSHALL BE POURED BETWEEN THE TWO. DISTANCES ARE MEASURED FROM OUTSIDE DIAMETER TO OUTSIDE DIAMETER.27.A FIRE INSPECTOR SHALL INSPECT THE UNDERGROUND FIRE LINE PIPING FROM THE PIV TO THE BUILDING. FOR YARDFIRE DEPARTMENT CONNECTIONS (FDCS), THE UNDERGROUND FDC PIPING MUST BE INSPECTED BEFORE IT IS COVEREDUP.28.GREASE INTERCEPTOR SIZING AND DETAILS ARE TO BE INCLUDED WITH BUILDING CONSTRUCTION PLUMBING PLANS.
RETAINING WALL NOTES
1.THERE SHALL BE NO TAPS, PIPING BRANCHES, UNAPPROVED BYPASS PIPING, HYDRANTS, FIRE DEPARTMENTCONNECTION POINTS OR OTHER WATER-USING APPURTENANCES CONNECTED TO THE SUPPLY LINE BETWEEN ANYWATER METER AND ITS ST. JOHNS WATER REQUIRED BACKFLOW PREVENTER.2.EACH ST. JOHNS WATER UTILITY DEPARTMENT REQUIRED BACKFLOW PREVENTER ASSEMBLY IS REQUIRED TO BETESTED BY AN APPROVED CERTIFIED TESTER PRIOR TO PLACING THE WATER SYSTEM INTO SERVICE.3.THE DOMESTIC BACKFLOW PREVENTER SHALL BE INSTALLED PER ST. JOHNS WATER REGULATIONS AT THE PROPERTYLINE AND AS SHOWN IN THE LOCATION OF THE UTILITY PLAN.4.THE FIRE BACKFLOW PREVENTER FOR THE FIRE SPRINKLER SYSTEM SHALL BE INSTALLED PER ST. JOHNS WATERREGULATIONS AT THE PROPERTY LINE AND AS SHOWN IN THE LOCATION OF THE UTILITY PLAN.
1.SIDEWALKS TO HAVE A MAXIMUM 2.00% CROSS SLOPE AND A MAXIMUM 5% LONGITUDINAL SLOPE.2.PEDESTRIAN CROSSWALKS TO HAVE MAXIMUM 2.00% CROSS SLOPE AND MAXIMUM 5.00% LONGITUDINAL SLOPEWITHIN STRIPED AREA.3.ADA PARKING AREAS AND ACCESSIBLE AREAS TO HAVE A MAXIMUM 2.00% SLOPE IN ALL DIRECTIONS.4.SIDEWALK INTERSECTIONS AND RAMP LANDINGS TO HAVE A MAXIMUM 2.00% SLOPE IN ALL DIRECTIONS.
FINE GRADING NOTES:
1.CONTRACTOR SHALL BE FAMILIAR WITH THE RULES, REQUIREMENTS, AND REGULATIONS ASSOCIATED WITH THE USACEPERMIT FOR THIS PROJECT.2.CONTRACTOR TO PROTECT THE WETLANDS TO REMAIN AT ALL TIMES, INCLUDING WRAPPING THE WETLANDS IN A DOUBLEROW OF SILT FENCE AS INDICATED ON THE EROSION AND SEDIMENTATION CONTROL PLAN.
WETLAND CONSTRUCTION NOTES:
1.REFER TO MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (LATEST EDITION) AND SCDOT STANDARDS FOR DETAILSOF STANDARD TRAFFIC CONTROL SIGNS AND STANDARDS.
TRAFFIC CONTROL:
1.ALL WORK AND MATERIALS SHALL COMPLY WITH ALL CITY OF CHARLESTON AND SCDOT REGULATIONS AND CODESAND O.S.H.A. STANDARDS.2.ALL CONTOURS AND SPOT ELEVATIONS REFLECT FINISHED GRADES. SPOT ELEVATIONS AT CURB LOCATIONS ARE TOTHE BOTTOM FACE OF CURB (FLOWLINE), UNLESS OTHERWISE NOTED.3.ALL ELEVATIONS ARE IN REFERENCE TO THE BENCHMARK, AND THIS MUST BE VERIFIED BY THE GENERALCONTRACTOR PRIOR TO GROUND BREAKING.4.THE CONTRACTOR SHALL IMMEDIATELY REPORT TO OWNER ANY DISCREPANCIES FOUND BETWEEN ACTUAL FIELDCONDITIONS AND CONSTRUCTION DOCUMENTS AND SHALL WAIT FOR INSTRUCTION PRIOR TO PROCEEDING.5.THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING AND PROTECTING EXISTING UTILITIES, AND SHALL REPAIRALL DAMAGE TO EXISTING UTILITIES THAT OCCUR DURING CONSTRUCTION.6.CONTRACTOR SHALL BLEND NEW EARTHWORK SMOOTHLY TO TRANSITION BACK TO EXISTING GRADE.7.ALL FILL TO BE COMPACTED PER THE RECOMMENDATIONS OF A GEOTECHNICAL ENGINEER.8.LIMITS OF CLEARING SHOWN ON GRADING PLAN ARE BASED UPON THE APPROXIMATE CUT AND FILL SLOPE LIMITS, OROTHER GRADING REQUIREMENTS.9.THE PROPOSED CONTOURS SHOWN IN DRIVES AND PARKING LOTS AND SIDEWALKS ARE FINISHED ELEVATIONSINCLUDING ASPHALT. REFER TO PAVEMENT CROSS SECTION DATA TO ESTABLISH CORRECT SUBBASE OR AGGREGATEBASE COURSE ELEVATIONS TO BE COMPLETED UNDER THIS CONTRACT.10.CONTRACTOR SHALL ENSURE POSITIVE DRAINAGE SO THAT RUNOFF WILL DRAIN BY GRAVITY FLOW ACROSS NEWPAVEMENT AREAS TO NEW OR EXISTING DRAINAGE INLETS OR SHEET OVERLAND.11.ANY GRADING, BEYOND THE LIMITS OF CONSTRUCTION AS SHOWN ON THE GRADING PLAN IS CONSIDERED AVIOLATION OF THE GRADING PERMIT AND SUBJECT TO A FINE.12.EXISTING TOPOGRAPHIC INFORMATION TAKEN FROM THE SURVEY REFERENCED IN THIS PLAN SET.13.THE CONTRACTOR SHALL ADHERE TO ALL TERMS & CONDITIONS AS OUTLINED IN THE GENERAL N.P.D.E.S. PERMIT FORSTORMWATER DISCHARGE ASSOCIATED WITH CONSTRUCTION ACTIVITIES AND ALL TERMS AND CONDITIONS IN THESTATE OR MUNICIPAL GRADING AND EROSION CONTROL PERMIT ISSUED FOR THIS PROJECT.14.ALL UNSURFACED AREAS DISTURBED BY GRADING OPERATION SHALL RECEIVE 4 INCHES OF TOPSOIL.15.CONTRACTOR SHALL STABILIZE AND WATER DISTURBED AREAS UNTIL A HEALTHY STAND OF GRASS IS OBTAINED.16.CONSTRUCTION SHALL COMPLY WITH ALL APPLICABLE GOVERNING CODES AND BE CONSTRUCTED TO THE SAME.17.THE CONTRACTOR IS RESPONSIBLE FOR THE DESIGN AND IMPLEMENTATION OF ALL SHEETING, SHORING, BRACINGAND SPECIAL EXCAVATION MEASURES REQUIRED TO MEET OSHA, FEDERAL, STATE AND LOCAL REGULATIONSPURSUANT TO THE INSTALLATION OF THE WORK INDICATED ON THESE DRAWINGS. THE DESIGN ENGINEER ACCEPTSNO RESPONSIBILITY FOR THE DESIGN(S) TO INSTALL SAID ITEMS.18.THE CONTRACTOR SHALL REFER TO THE ARCHITECTURAL PLANS FOR EXACT BUILDING DIMENSIONS, DOOR LOCATIONSAND EXACT UTILITY ENTRANCE LOCATIONS AND ELEVATIONS.19.ALL FILL MATERIALS, EXISTING BUILDING FOUNDATIONS, PAVEMENT AND UTILITY STRUCTURES, TOPSOIL AND ANYOTHER DELETERIOUS MATERIALS SHALL BE COMPLETELY REMOVED FROM WITHIN THE BEARING ZONE BELOW THESTRUCTURE.20.ALL FOUNDATION AND UTILITY EXCAVATION SHALL BE INSPECTED BY A QUALIFIED GEOTECHNIAL REPRESENTATIVE TODETERMINE WHETHER UNSUITABLE MATERIAL MUST BE REMOVED. ALL UNDESIRABLE MATTER SHALL BE REMOVED,BACKFILLED AND COMPACTED WITH SUITABLE MATERIAL AS REQUIRED BY THE GEOTECHNICAL REPRESENTATIVE ATCONTRACTOR'S EXPENSE.21.GRADES, ELEVATIONS AND LOCATIONS SHOWN ARE APPROXIMATE. AS DIRECTED BY THE ENGINEER, THEY MAY BEADJUSTED TO ACCOMMODATE UNFORESEEN CONDITIONS. STATIONS, OFFSETS AND ELEVATIONS REFER TO THECENTER OF DROP INLETS, MANHOLES AND JUNCTION BOXES, AND THE MIDPOINT OF THE LIP FOR CATCH BASINS.22.CONTRACTOR SHALL ADJUST AND/OR CUT EXISTING PAVEMENT AS NECESSARY TO ASSURE A SMOOTH FIT ANDCONTINUOUS GRADE.23.EXISTING AND PROPOSED GRADE CONTOUR INTERVALS SHOWN AT 1 FOOT.24.CONTRACTOR IS RESPONSIBLE FOR DEMOLITION OF EXISTING STRUCTURES INCLUDING REMOVAL OF ANY EXISTINGUTILITIES SERVING THE STRUCTURE. UTILITIES ARE TO BE REMOVED TO THE RIGHT-OF-WAY OR ABANDONED AT MAINAS REFERENCED IN THE PLANS.25.ALL CUT OR FILL SLOPES SHALL BE 3:1 OR FLATTER UNLESS OTHERWISE NOTED.26.ALL AREAS WITH 2:1 SLOPE OR ERODABLE SLOPES SHALL BE COVERED WITH ERONET MATTING OR APPROVED EQUALINSTALL PER MANUFACTURER'S INSTRUCTIONS.27.THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND/OR ELEVATION OF EXISTING UTILITIES ASSHOWN ON THESE PLANS IS BASED ON RECORDS OF THE VARIOUS UTILITY COMPANIES, AND WHERE POSSIBLE,MEASUREMENTS TAKEN IN THE FIELD. THE INFORMATION IS NOT TO BE RELIED ON AS BEING EXACT OR COMPLETE. THECONTRACTOR MUST CALL THE APPROPRIATE UTILITY COMPANIES AT LEAST 72 HOURS BEFORE ANY EXCAVATION TOREQUEST EXACT FIELD LOCATION OF UTILITIES.28.CONTRACTOR TO BE RESPONSIBLE FOR DEWATERING AS NECESSARY TO CONSTRUCT THE PROJECT AS SHOWN ONTHE PLANS. REFER TO GEOTECHNICAL REPORT FOR ADDITIONAL DEWATERING RECOMMENDATIONS.
GRADING:
EROSION CONTROL NOTES:1.CONTRACTOR IS RESPONSIBLE FOR PROPERLY DISPOSING OF EXCESS MATERIAL OFF-SITE.2.CONTRACTOR SHALL INSTALL AND MAINTAIN THROUGHOUT THE CONSTRUCTION PROJECT ALL EROSIONCONTROL COUNTER MEASURES SHOWN ON THIS SHEET IN ACCORDANCE WITH APPLICABLE STANDARDS ANDREGULATIONS FROM THE SOUTH CAROLINA DEPARTMENT OF ENVIRONMENTAL SERVICES (SCDES).3.GROUND COVER SHALL BE ESTABLISHED PER "SEEDBED PREPARATION NOTES" PROVIDED IN THE EROSIONCONTROL DETAILS.4. THE CONTRACTOR SHALL PROVIDE GROUND COVER ON DESIGNATED AREAS AND SLOPES GREATER THAN 3:1WITHIN 7 DAYS FOLLOWING COMPLETION OF ANY PHASE OF GRADING. CONTRACTOR SHALL PROVIDEGROUND COVER IN 14 DAYS ON ALL OTHER AREAS FOLLOWING COMPLETION OF ANY PHASE OF GRADING.PERMANENT GROUND COVER FOR ALL DISTURBED AREAS SHALL BE PROVIDED WITHIN 14 WORKING DAYSFOLLOWING THE COMPLETION OF CONSTRUCTION.5. DURING CONSTRUCTION OF THE PROJECT, SOIL STOCKPILES AND BORROW AREAS SHALL BE STABILIZED OR PROTECTED WITH SEDIMENT TRAPPING MEASURES. THE CONTRACTOR IS RESPONSIBLE FOR THE TEMPORARY PROTECTION AND PERMANENT STABILIZATION OF ALL SOIL STOCKPILESON SITE AS WELL AS BORROW AREAS AND SOIL INTENTIONALLY TRANSPORTED FROM THE PROJECT SITE.6.SEDIMENT BASINS AND TRAPS, PERIMETER DIKES, SEDIMENT BARRIERS AND OTHER MEASURES INTENDED TOTRAP SEDIMENT SHALL BE CONSTRUCTED AS A FIRST STEP IN ANY LAND-DISTURBING ACTIVITY AND SHALL BEMADE FUNCTIONAL BEFORE UPSLOPE LAND DISTURBANCE TAKES PLACE.7.WHERE CONSTRUCTION VEHICLE ACCESS ROUTES INTERSECT PAVED OR PUBLIC ROADS, PROVISIONS SHALLBE MADE TO MINIMIZE THE TRANSPORT OF SEDIMENT BY VEHICULAR TRACKING ONTO THE PAVED SURFACE.WHERE SEDIMENT IS TRANSPORTED ONTO A PAVED OR PUBLIC ROAD SURFACE, THE ROAD SURFACE SHALLBE CLEANED THOROUGHLY AT THE END OF EACH DAY. SEDIMENT SHALL BE REMOVED FROM THE ROADS BYSHOVELING OR SWEEPING AND TRANSPORTED TO A SEDIMENT CONTROL DISPOSAL AREA. STREET WASHINGSHALL BE ALLOWED ONLY AFTER SEDIMENT IS REMOVED IN THIS MANNER.8.ALL TEMPORARY EROSION AND SEDIMENT CONTROL MEASURE SHALL BE REMOVED WITHIN 30 DAYS AFTERFINAL SITE STABILIZATION OR AFTER THE TEMPORARY MEASURES ARE NO LONGER NEEDED AND APPROVALHAS BEEN OBTAINED FROM THE CITY OF CHARLESTON INSPECTOR. TRAPPED SEDIMENT AND THE DISTURBEDSOIL AREAS RESULTING FROM THE DISPOSITION OF TEMPORARY MEASURES SHALL BE PERMANENTLYSTABILIZED TO PREVENT FURTHER EROSION AND SEDIMENTATION.9.ALL EROSION CONTROL MEASURES SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE SCDES EROSION ANDSEDIMENT CONTROL REGULATIONS, U.S. DEPT. OF AGRICULTURE, AND U.S. SOIL CONSERVATION SERVICE.10.THE CONTRACTOR SHALL DILIGENTLY AND CONTINUOUSLY MAINTAIN ALL EROSION CONTROL DEVICES ANDSTRUCTURES TO MINIMIZE EROSION. THE CONTRACTOR SHALL MAINTAIN CLOSE CONTACT WITH THE EROSIONCONTROL INSPECTOR SO THAT PERIODIC INSPECTIONS CAN BE PERFORMED AT APPROPRIATE STAGES OFCONSTRUCTION.11.A COPY OF THE APPROVED EROSION AND SEDIMENT CONTROL PLAN AND PERMIT SHALL BE MAINTAINED ONTHE SITE AT ALL TIMES.12.STABILIZATION IS THE BEST FORM OF EROSION CONTROL. ALL DISTURBED AREAS WHICH ARE NOTOTHERWISE STABILIZED SHALL BE TOP SOILED AND SEEDED, TEMPORARILY OR PERMANENTLY INACCORDANCE WITH THE SCDES REGULATIONS. PERMANENT SEEDING AND GRASS ESTABLISHMENT ISREQUIRED PRIOR TO PROJECT COMPLETION AND ACCEPTANCE.13.CONTRACTOR TO ENSURE THAT SEDIMENT LADEN RUNOFF DOES NOT LEAVE SITE LIMITS OR ENTERPROTECTED AREAS. ANY SEDIMENT DEPOSITED BEYOND DISTURBED AREA WITHIN SITE LIMITS SHALL BEREMOVED.14.WHEN A CRUSHED STONE CONSTRUCTION ENTRANCE HAS BEEN COVERED WITH SOIL OR HAS BEEN PUSHEDINTO THE SOIL BY CONSTRUCTION TRAFFIC, IT SHALL BE REPLACED WITH A DEPTH OF STONE EQUAL TO THATOF THE ORIGINAL APPLICATION.15.ALL DRAINAGE INLETS SHALL BE PROTECTED FROM SILTATION. INEFFECTIVE PROTECTION DEVICES SHALL BEIMMEDIATELY REPLACED AND THE INLET CLEANED. FLUSHING IS NOT AN ACCEPTABLE METHOD OF CLEANING.16.DURING DEWATERING OPERATIONS, WATER SHALL BE PUMPED INTO AN APPROVED FILTERING DEVICE PRIORTO DISCHARGE TO RECEIVING OUTLET.17.STABILIZATION MEASURES SHALL BE APPLIED TO STRUCTURES SUCH AS DAMS, DIKES AND DIVERSIONSIMMEDIATELY AFTER INSTALLATION.
DEMOLITION NOTES:1.THE CONTRACTOR SHALL COORDINATE ALL REMOVAL EFFORTS WITH THE OWNER. COORDINATION ITEMS AREANTICIPATED TO INCLUDE SITE ACCESS, TRAFFIC CONTROL, MAINTENANCE OF ACCESS AND UTILITIES FOREXISTING BUILDINGS TO REMAIN, AND EROSION CONTROL.2.ALL FEATURES MARKED TO BE ABANDONED IN PLACE SHALL REMAIN IN EXISTING CONDITION UNLESSREMOVED THROUGH EFFORTS FOR OTHER FEATURES.3.SPECIAL CARE SHALL BE TAKEN TO PROTECT AND MAINTAIN ALL EXISTING FEATURES NOT MARKED FORREMOVAL. IN THE EVENT OF ANY IMPACT TO SUCH FEATURES, THE CONTRACTOR SHALL PERFORM REPAIRAND/OR RESTORATION TO ORIGINAL CONDITION AS OF START OF WORK.4.WHERE PAVEMENT REMOVAL AREAS ABUT OTHER PAVEMENT AREAS TO REMAIN, THE EXISTING PAVEMENTSHALL BE SAW CUT TO PROVIDE A BOUNDARY WHICH IS STRAIGHT AND CLEAN IN APPEARANCE.5.ALL SANITARY SEWER MAIN FEATURES WILL GENERALLY BE PROTECTED IN PLACE UNLESS SPECIFICALLYMARKED FOR REMOVAL.6.THE CONTRACTOR SHALL PROPERLY AND LEGALLY DISPOSE OF ALL DEMOLITION DEBRIS OFF OF THECONSTRUCTION SITE.
W W W W W W W W W W W W W W W W W
FMFMFMFMFMFMFMFM
7/7.5/10" WATER OAK(D)
12.5/13" WATER OAK(D)
12.5/15" MULBERRY(D)
13/14" WATER OAK(D)
31" RED OAK(D)
7/17" WATER OAK(D)
24" BLACK GUM(D)
16/16" RED OAK(C)
28/55" LIVE OAK(C)
60" LIVE OAK(B)
5/6/6/8/12" WATER OAK(D)
9/9/9" WATER OAK(D)
42" WATER OAK(D)
4/13/13" MAPLE(D)
2/5/8/10/10" MAPLE(D)
25" WATER OAK(D)
20/23" LIVE OAK(C)
18/23" LIVE OAK(C)
12/15" WATER OAK(C)
14/24" RED OAK(D)
3/5/18" WATER OAK(D)
31" WATER OAK(C)
42" LIVE OAK(C)
26" LIVE OAK(B)
34" MAGNOLIA(C)
26" WATER OAK(D)
24" WATER OAK(C)
24" LIVE OAK(C)
32" WATER OAK(C)
15/22" WATER OAK(D)
3/7/9/11" WATER OAK(D)
3/7/9/11" WATER OAK(D)
3/7/9/11" WATER OAK(D)
25" WATER OAK(D)
24" WATER OAK(D)
14/16" WATER OAK(NON GRADED)
25" WATER OAK(D)
3/7/7/12" MAPLE(D)
10/16" MAPLE(D)
SHEET NUMBERPROJECT:
TITLE:
No. DATEBY
Drawing name: K:\CHA_LDEV\018278 Cooper Law Firm\100 Maybank PUD\02 - DWG\PlanSheets\C1-00 - EX COND AND DEMO PLAN.dwg C1-00 EXISTING CONDITIONS AND DEMOLITION PLAN Aug 19, 2026 11:28am by: Devin.FrankThis document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose and client for which it was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Kimley-Horn and Associates, Inc. shall be without liability to Kimley-Horn and Associates, Inc.
PRELIMINARY: NOT FOR CONSTRUCTION
© 2026 KIMLEY-HORN AND ASSOCIATES, INC.1080 MORRISON DRIVE, SUITE 240CHARLESTON, SOUTH CAROLINA 29403PHONE (843) 737-6390WWW.KIMLEY-HORN.COM
CLIENT:
CERTIFICATE OF AUTHORIZATIONAND
No. C00166INC
KIMLEY-HORNASSOCIATES,
TUSO NILAHCROA
PRELIMINARYNOT FOR CONSTRUCTION
REVISIONS0ISSUED FOR PERMIT REVIEW12-12-2025KHA1ISSUED FOR PERMIT REVIEWKHA2ISSUED FOR PERMIT REVIEWKHA3ISSUED FOR PERMIT REVIEWKHA05-11-202606-29-202608-18-2026COOPER LAW FIRM474 WANDO PARK BLVD,SUITE 105MT. PLEASANT, SC 29464PHONE: 843.881.5413
MAYBANK SUBDIVISIONCONCEPT PLANMAYBANK HIGHWAY, JOHNS ISLAND, SC 29455
SCALE:DRAWN BY:DESIGNED BY:CHECKED BY:
AS SHOWN
QRDGCC
KHA
KHA PROJECT NO.01827810002/09/2026DATE:
C1-00EXISTING CONDITIONSPLAN
NORTH
EXISTING CONDITIONS NOTES:1.EXISTING CONDITIONS SHOWN HEREON ARE FROM A SURVEYFILE PROVIDED BY HLA, INC. DATED 03/13/2025.2.UTILITIES MAY EXIST WHICH ARE NOT SHOWN ON THE PLANS.THE CONTRACTOR SHALL BE RESPONSIBLE FOR CONTACTINGALL UTILITY COMPANIES HAVING UTILITIES WITHIN ORADJACENT TO THE WORK AREA. THE CONTRACTOR SHALLHAVE THE UTILITIES FIELD LOCATED AND COORDINATE WITHTHE UTILITY COMPANIES TO HAVE CONFLICTS RELOCATEDWHEN NECESSARY OR ADAPTED FOR TIE-INS.3.WHERE EXISTING RUNOFF LEAVES THE SITE IN A SHEET FLOWCONDITION, RUNOFF SHALL LEAVE THE SITE IN A SHEET FLOWCONDITION AFTER DEVELOPMENT.4.RECEIPT OF ALL PERMITS AND APPROVALS IS REQUIREDBEFORE ANY CONSTRUCTION ACTIVITY.5.TREES TO REMAIN MUST BE PROTECTED DURING DEMOLITIONAND CONSTRUCTION PHASE. REFERENCE TREE PROTECTIONAND REPLACEMENT PLANS FOR TREE REMOVAL ANDPROTECTION.6.CONSTRUCTION FENCING OR SILT FENCE SHALL NOTOBSTRUCT TRAFFIC FLOW ON EXISTING STREETS UNLESSCLOSURE PERMIT IS OBTAINED.7.CONTRACTOR SHALL CONTROL DUST LEAVING THE SITEDURING DEMOLITION AND CONSTRUCTION.8.CONTRACTOR SHALL COORDINATE UTILITY DEMOLITION ANDRELOCATION WITH APPROPRIATE UTILITY PROVIDER.9.CONTRACTOR SHALL PROTECT SURROUNDING BUILDINGUTILITY SERVICES DURING CONSTRUCTION AND COORDINATEALL SERVICE IMPACTS WITH OWNER.10.NO GRADED SLOPE SHALL EXCEED 2H:1V.11.THE PROJECT SITE DOES NOT LIE WITHIN A FLOOD HAZARDAREA PER FIRM PANEL 45019C0655K DATED 01/29/2021.12.CONTRACTOR SHALL MAINTAIN AN ADA COMPLIANTPEDESTRIAN PATH ALONG THE ADJACENT STREET FRONTAGETHROUGHOUT CONSTRUCTION.13.CONTRACTOR SHALL FOLLOW ALL PROCEDURES ANDRECOMMENDATIONS FROM ENVIRONMENTAL ASSESSMENTSPROVIDED BY THE OWNER.14.CONTRACTOR SHALL PREPARE A PROJECT NOTIFICATION FORASBESTOS RENOVATION, ENCAPSULATION, OR DEMOLITIONFORM AND SUBMIT TO THE EPD ASBESTOS PROGRAM 10 DAYSPRIOR TO DEMOLITION ACTIVITIES. FORM SHALL BEPREPARED AND ASBESTOS STUDY COMPLETED TO MEET EPDAND LOCAL REQUIREMENTS.
GRADE A
GRADE D
GRADE F
GRADE B
TREE PROTECTION ZONE
GRADE C
TREE GRADES:
SOUTHWICK DRIVE (S-1153) SCDOT MAINTAINED 66' R/W
MAYBANK HWY (SC-700) SCDOT MAINTAINED 60' R/W
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
X
X
X
X
X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X
W W W W W W W W W W W W W W W W W
FMFMFMFMFMFMFMFM
60" LIVE OAK(B)
42" WATER OAK(D)
4/13/13" MAPLE(D)
2/5/8/10/10" MAPLE(D)
18/23" LIVE OAK(C)
3/5/18" WATER OAK(D)
31" WATER OAK(C)
42" LIVE OAK(C)
14/16" WATER OAK(NON GRADED)
10/16" MAPLE(D)
A
B
A
AC
C
D
E
F
PROPERTY LINE (TYP.)
PROPERTY LINE (TYP) 40' ROW
50' CITY OF CHARLESTONMAINTAINED ROW
50' CITY OF CHARLESTONMAINTAINED ROW
D
PROPOSED 10' G.U.E.PROPERTY LINE (TYP)
20'
R30'B
12'12' 35'
5' SIDEWALK (TYP.)
SEA ISLAND HABITATFOR HUMANITYRESTORE
SEA ISLAND HABITATFOR HUMANITYRESTORE PARKING LOT
X
X
X
X
XX
X
EXISTING 14/24" GRADE DWATER OAK TO BE REMOVED
EXISTING 12"/15" GRADE CWATER OAK TO BE REMOVED
EXISTING 16/16" GRADE CRED OAK TO BE REMOVED
EXISTING 5/6/6/8/12" GRADE DWATER OAK TO BE REMOVED
EXISTING 9"/9"/9" GRADE DWATER OAK TO BE REMOVED
PROPOSED 10' G.U.E.
PROPOSED 10' G.U.E.PROPOSED 10' MAINTENANCESHELF AND ACCESS EASEMENT
PROPOSED 10' MAINTENANCESHELF AND ACCESS EASEMENT
PROPOSED 20' DRAINAGEAND ACCESS EASEMENT
D
JURISDICTIONAL WETLAND ±0.26 ACRES IMPACTED
JURISDICTIONAL WETLAND±0.04 ACRES±262 LF IMPACTED
NON-JURISDICTIONALWETLAND ±0.12ACRES IMPACTED
X
EXISTING 24" GRADE DWATER OAK TO BE REMOVED
X
X
X
XX
XX XX
X
XX
X
X X
X
X
EXISTING 32" GRADEC WATER OAK TO BEREMOVED
EXISTING26" GRADED LIVEOAK TO BEREMOVED
EXISTING 26" GRADE BLIVE OAK TO BE REMOVED
EXISTING 24" GRADE CWATER OAK TO BE REMOVED
EXISTING 12.5"/13" GRADE DWATER OAK TO BE REMOVED
EXISTING 28"/55" GRADE CLIVE OAK TO BE REMOVEDEXISTING 12.5"/15" GRADE DMULBERRY TO BE REMOVED
EXISTING 13"/14"GRADE D WATER OAKTO BE REMOVED
EXISTING 25" GRADE DWATER OAK TO BE REMOVED
EXISTING 12"/13" GRADE DWATER OAK TO BE REMOVED
EXISTING 15"/22"GRADE D WATER OAKTO BE REMOVED
EXISTING 3"/7"/9"/11"GRADE D WATER OAKTO BE REMOVEDEXISTING 12"/13" GRADE DWATER OAK TO BE REMOVED
EXISTING 20"/23"GRADE C LIVE OAKTO BE REMOVED
EXISTING 24" GRADED BLACK GUM TO BEREMOVED
EXISTING 31" RED GRADE DOAK TO BE REMOVED
EXISTING 7"/17" GRADE DWATER OAK TO BE REMOVED
EXISTING 10"/10"/10"CHERRY TO BEREMOVED EXISTING 3"/7"/7"/12" GRADE DWATER OAK TO BE REMOVED
10' LANDSCAPE BUFFER
20' MAINTENANCE SHELF ANDPROPOSED ACCESS EASEMENT
R150'
R150'
R45'
X
EXISTING 25" GRADED WATER OAK TO BEREMOVED
DB
R250'
JURSIDICTIONAL WETLAND ±0.03 ACRES IMPACTED
20
PROPOSED 20' CWSSEWER EASEMENT
PROPOSED 10' MAINTENANCESHELF AND ACCESSEASEMENT
PROPOSED 24' DRAINAGEEASEMENT E
10' WETLAND BUFFER
20'
JURISDICTIONAL WETLAND±0.10 ACRES IMPACTED
R30'R30'
B
DRIVEWAY EXTENSION BYOTHERS. SHOWN FORCLARITY PURPOSES ONLY.
12'
12'
R40'
R40'
R250' R20'R20'
INFILTRATIONBASIN 3INFILTRATIONBASIN 2
INFILTRATIONBASIN 1
INFILTRATIONBASIN 4
SEA ISLAND HABITATFOR HUMANITYRESTORE
SEA ISLAND HABITATFOR HUMANITYRESTORE PARKING LOT
PRESERVEDWETLAND
PRESERVEDWETLAND
POCKETPARK
PARK
POCKETPARK
EXISTINGWET POND
INFILTRATIONBASIN 5
75'
75' LANDSCAPE BUFFER
24'
113' TO NEARESTDRIVEWAY
199' TO NEARESTINTERSECTION
EXISTING DITCH TO USE EXISTING 17.5'DRAINAGE EASEMENT
11'
11'
13
PROPOSED 30' CITY OF CHARLESTONDRAINAGE EASEMENT
PROPOSED10'MAINTENANCE SHELF ANDACCESS EASEMENT
EXISTING 17.5' PRIVATEDRAINAGE EASEMENT
PROPOSED VARIABLE WIDTHCITY OF CHARLESTONDRAINAGE EASEMENT WITH15' MAINTENANCE SHELF ONWEST SIDE
PROPOSED VARAIBLEWIDTH CITY OFCHARLESTONDRAINAGE EASEMENT
PROPOSED 30' CITYOF CHARLESTONDRAINAGE EASEMENT
PROPOSED 30' CITY OF CHARLESTONDRAINAGE EASEMENT
LOT 62
LOT 61
LOT 60
LOT 59
LOT 58
LOT 57
LOT 56
LOT 55
LOT 54
LOT 53
LOT 52
LOT 51
LOT 50
LOT 49
LOT 48
LOT 47
LOT 46
LOT 45
LOT 44
LOT 43
LOT 42
LOT 41
LOT 40
LOT 39
LOT 38
LOT 37
LOT 36
LOT 35
LOT 34
LOT 33
LOT 32LOT 31LOT 30LOT 29
LOT 28LOT 27LOT 26LOT 25LOT 24LOT 23LOT 22LOT 21LOT 20LOT 19LOT 18LOT 17
LOT 16LOT 15LOT 14LOT 13LOT 12LOT 11
LOT 10LOT 9LOT 8LOT 7LOT 6LOT 5
LOT 4LOT 3LOT 2LOT 1
PROPOSED ON-STREETPARKING - TYP.
BRIGHT OAKPRESCHOOLACADEMY
X
EXISTING 24" GRADE CLIVE OAK TO BE REMOVED
X
EXISTING 25" GRADE DWATER OAK TO BE REMOVED
30'
± 790 LFPROPOSED RETAININGWALL WITH SAFETY RAIL. MAX HEIGHT: ±3.5'
± 700 LFPROPOSED RETAININGWALL WITH SAFETY RAIL. MAX HEIGHT: ±4'
± 220 LFPROPOSED RETAININGWALL. MAX HEIGHT: ±1.5'
PROPOSED 15' CITY OFCHARLESTON DRAINAGE EASEMENT44'
49'
43'
46'
PROPOSED VARIABLE WIDTHCITY OF CHARLESTONDRAINAGE EASEMENT TOSTART WHERE EXISTINGDITCH TRANSITIONS TO 4'DEPTH
SHEET NUMBERPROJECT:
TITLE:
No. DATEBY
Drawing name: K:\CHA_LDEV\018278 Cooper Law Firm\100 Maybank PUD\02 - DWG\PlanSheets\C2-00 - SITE PLAN.dwg C2-00 SITE PLAN Aug 19, 2026 12:49pm by: Devin.FrankThis document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose and client for which it was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Kimley-Horn and Associates, Inc. shall be without liability to Kimley-Horn and Associates, Inc.
PRELIMINARY: NOT FOR CONSTRUCTION
© 2026 KIMLEY-HORN AND ASSOCIATES, INC.1080 MORRISON DRIVE, SUITE 240CHARLESTON, SOUTH CAROLINA 29403PHONE (843) 737-6390WWW.KIMLEY-HORN.COM
CLIENT:
CERTIFICATE OF AUTHORIZATIONAND
No. C00166INC
KIMLEY-HORNASSOCIATES,
TUSO NILAHCROA
PRELIMINARYNOT FOR CONSTRUCTION
REVISIONS0ISSUED FOR PERMIT REVIEW12-12-2025KHA1ISSUED FOR PERMIT REVIEWKHA2ISSUED FOR PERMIT REVIEWKHA3ISSUED FOR PERMIT REVIEWKHA05-11-202606-29-202608-18-2026COOPER LAW FIRM474 WANDO PARK BLVD,SUITE 105MT. PLEASANT, SC 29464PHONE: 843.881.5413
MAYBANK SUBDIVISIONCONCEPT PLANMAYBANK HIGHWAY, JOHNS ISLAND, SC 29455
SCALE:DRAWN BY:DESIGNED BY:CHECKED BY:
AS SHOWN
QRDGCC
KHA
KHA PROJECT NO.01827810002/09/2026DATE:
C2-00SITE PLAN
ABCDEF
SITE KEYNOTE LEGEND:5' CONCRETE SIDEWALK2' THERMOPLASTIC STOP BAR AND STOP SIGNPROPOSED 18" MOUNTABLE CURBADA CROSSWALK, 4" SOLID WHITE STRIPE
SPEED LIMIT SIGN (W13-1)WITH ALL RESIDENTIAL SIGN (R2-20-24)ADA ACCESSIBLE RAMP
BUILDING AREA
LANDSCAPE BUFFER
PROPERTY LINE
STANDARD DUTY ASPHALT PAVEMENT
STANDARD DUTY CONCRETE SIDEWALK
SITE PLAN LEGEND:
WETLAND IMPACTS
DEVELOPMENT SUMMARY:SITE SUMMARY:CURRENT ZONING:TMS #2790000288: RR-1 (RURAL RESIDENTIAL)TMS #2790000008: RR-1 (RURAL RESIDENTIAL)TMS #2790000009: RR-1 (RURAL RESIDENTIAL)TMS #2790000010: RR-1 (RURAL RESIDENTIAL)TMS #2790000017: RR-1 (RURAL RESIDENTIAL)TMS #3130000047: RR-1 (RURAL RESIDENTIAL)TMS #3130000237: RR-1 (RURAL RESIDENTIAL)TMS #3130000006: GB (GENERAL BUSINESS)PROPOSED ZONING:PUD (PLANNED UNIT DEVELOPMENT)GROSS AREA: 13.47 ACRESROW DEDICATION:4.78 ACRESADJUSTED SITE AREA:8.69ACRESWETLAND AREA:1.60ACRESTOTAL WETLAND IMPACTS:0.56ACRESJURISDICTIONAL:0.43 ACRESNON-JURISDICTIONAL:0.13ACRESIMPERVIOUS AREA:5.20 ACRES (38.6%)PERVIOUS AREA:8.27 ACRES (61.4%)OPEN SPACE:4.91 ACRES (36.5%)USEABLE OPEN SPACE:2.14 ACRES (43.6%)TOTAL DISTURBED AREA:12.3 ACRESBUILDING SETBACK:FRONT: 20 FTSIDE: 5 FTBACK: 10 FT REQUIRED ON-STREET PARKING: 1 PER EVERY 3 LOTS (21 SPACES) PROVIDED ON-STREET PARKING: 21 SPACES
PROPOSED LAND USES & DENSITIES:LOTSRESIDENTIAL:62 LOTSHOA: 5 LOTSCOMMERCIAL:1 LOTUNITSSINGLE FAMILY DETACHED:30 UNITSSINGLE FAMILY ATTACHED (TOWNHOMES): 32 UNITSCOMMERCIAL DISTRICT (CD)2.29 ACRES (15%)RESIDENTIAL DISTRICT (RD)13.32 ACRES (85%)NET DENSITY4.65 UNITS/ACRE
SITE NOTES:1.EXISTING CONDITIONS SHOWN HEREON ARE FROM A SURVEY FILE PROVIDED BY HLA,INC., DATED 03/13/2025.2.ALL DIMENSIONS ARE FROM FACE OF CURB TO FACE OF CURB UNLESS OTHERWISENOTED.3.SIDEWALK INSTALLED AGAINST BACK OF CURB SHALL BE INSTALLED PER THE PLANAS MEASURED FROM THE FACE OF CURB.4.ALL SIGNAGE AND STRIPING MUST MEET THE LATEST REQUIREMENTS SET FORTH BYMUTCD, SCDOT, AND SOUTH CAROLINA STATE CODE.5.REFERENCE LANDSCAPE PLANS FOR ALL HARDSCAPE AND LANDSCAPE DETAILS ANDSPECIFICATIONS.
NORTH
REMOVE EXISTING TREEX
HEAVY DUTY CONCRETE PAVEMENT
G6' SCREEN WALL (BY OTHERS)
PURPOSE:MAYBANK SUBDIVISION DEVELOPMENT IS DESIGNED TO ADVANCE THE GOALS OF THECHARLESTON CITY PLAN, PARTICULARLY ITS EMPHASIS ON CREATING A CONNECTED,INCLUSIVE, AND RESILIENT COMMUNITY. THE DEVELOPMENT SUPPORTS A MIX OFHOUSING TYPES THAT ALIGN WITH THE CITY’S FUTURE LAND USE DESIGNATIONS ANDHOUSING AFFORDABILITY STRATEGIES. IN KEEPING WITH THE RESILIENCE AND EQUITYFRAMEWORK OF THE CITY PLAN, THE DEVELOPMENT PROMOTES EQUITABLE ACCESS TOHOUSING, TRANSPORTATION, AND GREEN SPACE, WHILE PRESERVING THE NATURALCHARACTER OF JOHNS ISLAND WITHIN THE URBAN GROWTH BOUNDARY
SOUTHWICK DRIVE (S-1153) SCDOT MAINTAINED 66' R/W
MAYBANK HWY (SC-700) SCDOT MAINTAINED 60' R/W
MAYBANK HWY (SC-700) SCDOT MAINTAINED 60' R/W
SOUTHWICK DRIVE (S-1153) SCDOT MAINTAINED 66' R/W
60" LIVE OAK(B)
42" WATER OAK(D)
4/13/13" MAPLE(D)
2/5/8/10/10" MAPLE(D)
18/23" LIVE OAK(C)
3/5/18" WATER OAK(D)
31" WATER OAK(C)
42" LIVE OAK(C)
14/16" WATER OAK(NON GRADED)
10/16" MAPLE(D)
LOT 62
LOT 61
LOT 60
LOT 59
LOT 58
LOT 57
LOT 56
LOT 55
LOT 54
LOT 53
LOT 52
LOT 51
LOT 50
LOT 49
LOT 48
LOT 47
LOT 46
LOT 45
LOT 44
LOT 43
LOT 42
LOT 41
LOT 40
LOT 39
LOT 38
LOT 37
LOT 36
LOT 35
LOT 34
LOT 33
LOT 32LOT 31LOT 30LOT 29
LOT 28LOT 27LOT 26LOT 25LOT 24LOT 23LOT 22LOT 21LOT 20LOT 19LOT 18LOT 17
LOT 16LOT 15LOT 14LOT 13LOT 12LOT 11
LOT 10LOT 9LOT 8LOT 7LOT 6LOT 5
LOT 4LOT 3LOT 2LOT 1
BRIGHT OAKPRESCHOOLACADEMY
PROPERTY LINE (TYP.)
10' LANDSCAPE BUFFER
75' LANDSCAPE BUFFER
PEDESTRIAN BRIDGE (TYP.)
PUD BOUNDARY (TYP.)8' PEDESTRIAN PATH
8' PEDESTRIAN PATH
10' PEDESTRIAN PATH
INFILTRATIONBASIN 3INFILTRATIONBASIN 2
INFILTRATIONBASIN 1
SEA ISLAND HABITATFOR HUMANITYRESTORE
SEA ISLAND HABITATFOR HUMANITYRESTORE PARKING LOT
PRESERVEDWETLAND
PRESERVEDWETLAND
POCKETPARK
PARK
POCKETPARK
POCKETPARK
EXISTINGPOND EXISTINGDRY POND
INFILTRATIONBASIN 5
INFILTRATIONBASIN 4
PASSIVE OPEN SPACEPROVIDED: 1.47 AC
USEABLE OPEN SPACEREQUIRED: 0.78PROVIDED: 2.14 AC
CONSTRUCTED WATER FEATURE /PRESERVED WETLAND
8' AND 10' TRAIL
HOA OR POA MAINTAINED AREAS NOTCONSIDERED TO BE OPEN SPACE
TOTAL OPEN SPACEREQUIRED: 3.12 ACPROVIDED: 3.61 AC (2.14 AC USABLE OPENSPACE + 1.47 AC PASSIVE OPEN SPACE)
SHEET NUMBERPROJECT:
TITLE:
No. DATEBY
Drawing name: K:\CHA_LDEV\018278 Cooper Law Firm\100 Maybank PUD\02 - DWG\PlanSheets\C2-10 - OPEN SPACE PLAN.dwg OPEN SPACE Aug 19, 2026 11:28am by: Devin.FrankThis document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose and client for which it was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Kimley-Horn and Associates, Inc. shall be without liability to Kimley-Horn and Associates, Inc.
PRELIMINARY: NOT FOR CONSTRUCTION
© 2026 KIMLEY-HORN AND ASSOCIATES, INC.1080 MORRISON DRIVE, SUITE 240CHARLESTON, SOUTH CAROLINA 29403PHONE (843) 737-6390WWW.KIMLEY-HORN.COM
CLIENT:
CERTIFICATE OF AUTHORIZATIONAND
No. C00166INC
KIMLEY-HORNASSOCIATES,
TUSO NILAHCROA
PRELIMINARYNOT FOR CONSTRUCTION
REVISIONS0ISSUED FOR PERMIT REVIEW12-12-2025KHA1ISSUED FOR PERMIT REVIEWKHA2ISSUED FOR PERMIT REVIEWKHA3ISSUED FOR PERMIT REVIEWKHA05-11-202606-29-202608-18-2026COOPER LAW FIRM474 WANDO PARK BLVD,SUITE 105MT. PLEASANT, SC 29464PHONE: 843.881.5413
MAYBANK SUBDIVISIONCONCEPT PLANMAYBANK HIGHWAY, JOHNS ISLAND, SC 29455
SCALE:DRAWN BY:DESIGNED BY:CHECKED BY:
AS SHOWN
QRDGCC
KHA
KHA PROJECT NO.01827810002/09/2026DATE:
SHEET NUMBERPROJECT:
TITLE:
No. DATEBY
Drawing name: K:\CHA_LDEV\018278 Cooper Law Firm\100 Maybank PUD\02 - DWG\PlanSheets\C2-10 - OPEN SPACE PLAN.dwg OPEN SPACE Aug 19, 2026 11:28am by: Devin.FrankThis document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose and client for which it was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Kimley-Horn and Associates, Inc. shall be without liability to Kimley-Horn and Associates, Inc.
PRELIMINARY: NOT FOR CONSTRUCTION
© 2026 KIMLEY-HORN AND ASSOCIATES, INC.1080 MORRISON DRIVE, SUITE 240CHARLESTON, SOUTH CAROLINA 29403PHONE (843) 737-6390WWW.KIMLEY-HORN.COM
CLIENT:
CERTIFICATE OF AUTHORIZATIONAND
No. C00166INC
KIMLEY-HORNASSOCIATES,
TUSO NILAHCROA
PRELIMINARYNOT FOR CONSTRUCTION
REVISIONS0ISSUED FOR PERMIT REVIEW12-12-2025KHA1ISSUED FOR PERMIT REVIEWKHA2ISSUED FOR PERMIT REVIEWKHA3ISSUED FOR PERMIT REVIEWKHA05-11-202606-29-202608-18-2026COOPER LAW FIRM474 WANDO PARK BLVD,SUITE 105MT. PLEASANT, SC 29464PHONE: 843.881.5413
MAYBANK SUBDIVISIONCONCEPT PLANMAYBANK HIGHWAY, JOHNS ISLAND, SC 29455
SCALE:DRAWN BY:DESIGNED BY:CHECKED BY:
AS SHOWN
QRDGCC
KHA
KHA PROJECT NO.01827810002/09/2026DATE:
SHEET NUMBERPROJECT:
TITLE:
No. DATEBY
Drawing name: K:\CHA_LDEV\018278 Cooper Law Firm\100 Maybank PUD\02 - DWG\PlanSheets\C2-10 - OPEN SPACE PLAN.dwg OPEN SPACE Aug 19, 2026 11:28am by: Devin.FrankThis document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose and client for which it was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Kimley-Horn and Associates, Inc. shall be without liability to Kimley-Horn and Associates, Inc.
PRELIMINARY: NOT FOR CONSTRUCTION
© 2026 KIMLEY-HORN AND ASSOCIATES, INC.1080 MORRISON DRIVE, SUITE 240CHARLESTON, SOUTH CAROLINA 29403PHONE (843) 737-6390WWW.KIMLEY-HORN.COM
CLIENT:
CERTIFICATE OF AUTHORIZATIONAND
No. C00166INC
KIMLEY-HORNASSOCIATES,
TUSO NILAHCROA
PRELIMINARYNOT FOR CONSTRUCTION
REVISIONS0ISSUED FOR PERMIT REVIEW12-12-2025KHA1ISSUED FOR PERMIT REVIEWKHA2ISSUED FOR PERMIT REVIEWKHA3ISSUED FOR PERMIT REVIEWKHA05-11-202606-29-202608-18-2026COOPER LAW FIRM474 WANDO PARK BLVD,SUITE 105MT. PLEASANT, SC 29464PHONE: 843.881.5413
MAYBANK SUBDIVISIONCONCEPT PLANMAYBANK HIGHWAY, JOHNS ISLAND, SC 29455
SCALE:DRAWN BY:DESIGNED BY:CHECKED BY:
AS SHOWN
QRDGCC
KHA
KHA PROJECT NO.01827810002/09/2026DATE:
BUILDING AREALANDSCAPE BUFFER
PROPERTY LINE
STANDARD DUTY ASPHALTPAVEMENTSTANDARD DUTY CONCRETESIDEWALK
SITE PLAN LEGEND:
SITE NOTES:1.EXISTING CONDITIONS SHOWN HEREON ARE FROM A SURVEY FILE PROVIDEDBY HLA, INC., DATED 03/13/2025.2.ALL DIMENSIONS ARE FROM FACE OF CURB TO FACE OF CURB UNLESSOTHERWISE NOTED.3.SIDEWALK INSTALLED AGAINST BACK OF CURB SHALL BE INSTALLED PER THEPLAN AS MEASURED FROM THE FACE OF CURB.4.ALL SIGNAGE AND STRIPING MUST MEET THE LATEST REQUIREMENTS SETFORTH BY MUTCD, SCDOT, AND SOUTH CAROLINA STATE CODE.5.REFERENCE LANDSCAPE PLANS FOR ALL HARDSCAPE AND LANDSCAPEDETAILS AND SPECIFICATIONS.
HEAVY DUTY CONCRETEPAVEMENT
NORTH
DEVELOPMENT SUMMARY:SITE SUMMARY:GROSS SITE AREA:15.61 ACRESCOMMERCIAL DISTRICT:2.29ACRESRESIDENTIAL DISTRICT:13.32ACRES
REQUIRED OPEN SPACE:3.12ACRES (20% OF GROSS AREA)PROVIDED OPEN SPACE:4.91 ACRES (31.5% OF GROSS AREA)REQUIRED USABLE OPEN SPACE:0.78ACRES (25% OF REQUIRED OPEN SPACE)PROVIDED USABLE OPEN SPACE:2.14ACRES (43.6% OF TOTAL OPEN SPACE)WATER FEATURE/PRESERVED WETLAND: 2.61ACRESWATER FEATURE/PRESERVED WETLANDCOUNTED TOWARDS OPEN SPACE:1.30ACRES (50% OF TOTAL)PROVIDED PASSIVE OPEN SPACE:1.47ACRESHOA OR POA MAINTAINED AREAS NOTCONSIDERED TO BE OPEN SPACE:0.53ACRES
C2-10OPEN SPACE
PUD BOUNDARY
WEED BARRIERCOMPACTEDSUBGRADE
CRUSHED CONCRTE3"
8' / 10' (TYP)
2% CROSS SLOPETOWARD DRAINAGE(OR APPROVED EQUAL)
1. PATHS TO BE FIELD ADJUSTEDNOTES:BY LANDSCAPE ARCHITECT IF NECESSARY.2. PATHS TO BE FIELD ADJUSTEDTO AVOID NATURAL FEATURES
1. EXCAVATE MIN. 3" ALONG TRAIL PATHINSTALLATION NOTES:2. COMPACT SUBGRADE 3. INSTALL NON-WOVEN LANDSCAPE FABRIC 4. INSTALL APPROVED PATH MATERIAL AND COMPACT
8' / 10' PATH DETAIL NTS
PROPOSED IMPROVEMENTSPARK: +/ 5,000 SQFT-PLAYGROUND-TABLES-PAVILIONS-DOG FRIENDLY AREAS-OUTDOOR FITNESS AREAS-COMMUNITY GARDENSOTHER AMENITY FEATURES MAY BE ALLOWED AS APPROVED BY THE CITY OFCHARLESTON'S TRCPOCKET PARK: +/ 2,000 SQFT-GRILLS-BENCHES-SMALL TABLES-LAWN GAMES-POLLINATOR GARDENSOTHER AMENITY FEATURES MAY BE ALLOWED AS APPROVED BY THE CITY OFCHARLESTON'S TRC
PEDESTRIAN TRAILCONNECTION POINTS
SOUTHWICK DRIVE (S-1153) SCDOT MAINTAINED 66' R/W
MAYBANK HWY (SC-700) SCDOT MAINTAINED 60' R/W
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
X
X
X
X
X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X
W W W W W W W W W W W W W W W W W
FMFMFMFMFMFMFMFM
60" LIVE OAK(B)
42" WATER OAK(D)
4/13/13" MAPLE(D)
2/5/8/10/10" MAPLE(D)
18/23" LIVE OAK(C)
3/5/18" WATER OAK(D)
31" WATER OAK(C)
42" LIVE OAK(C)
14/16" WATER OAK(NON GRADED)
10/16" MAPLE(D)PROPOSED ADA ROUTE
PROPOSED ADA ROUTE
PROPOSED ADA ROUTEPROPERTY LINE (TYP)
CROSS ISLAND EXTENSION
INFILTRATION BASIN 3INFILTRATION BASIN 2
INFILTRATION BASIN 1 INFILTRATIONBASIN 5
INFILTRATIONBASIN 4
LOT 62
LOT 61
LOT 60
LOT 59
LOT 58
LOT 57
LOT 56
LOT 55
LOT 54
LOT 53
LOT 52
LOT 51
LOT 50
LOT 49
LOT 48
LOT 47
LOT 46
LOT 45
LOT 44
LOT 43
LOT 42
LOT 41
LOT 40
LOT 39
LOT 38
LOT 37
LOT 36
LOT 35
LOT 34
LOT 33
LOT 32LOT 31LOT 30LOT 29LOT 28LOT 27LOT 26LOT 25LOT 24LOT 23
LOT 22LOT 21LOT 20LOT 19LOT 18LOT 17LOT 16LOT 15LOT 14LOT 13LOT 12LOT 11LOT 10LOT 9LOT 8LOT 7LOT 6LOT 5LOT 4LOT 3LOT 2LOT 1
SHEET NUMBERPROJECT:
TITLE:
No. DATEBY
Drawing name: K:\CHA_LDEV\018278 Cooper Law Firm\100 Maybank PUD\02 - DWG\PlanSheets\C2-15 - ACCESSIBLE ROUTE PLAN.dwg C2-15 ACCESSIBLE ROUTE PLAN Aug 19, 2026 11:28am by: Devin.FrankThis document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose and client for which it was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Kimley-Horn and Associates, Inc. shall be without liability to Kimley-Horn and Associates, Inc.
PRELIMINARY: NOT FOR CONSTRUCTION
© 2026 KIMLEY-HORN AND ASSOCIATES, INC.1080 MORRISON DRIVE, SUITE 240CHARLESTON, SOUTH CAROLINA 29403PHONE (843) 737-6390WWW.KIMLEY-HORN.COM
CLIENT:
CERTIFICATE OF AUTHORIZATIONAND
No. C00166INC
KIMLEY-HORNASSOCIATES,
TUSO NILAHCROA
PRELIMINARYNOT FOR CONSTRUCTION
REVISIONS0ISSUED FOR PERMIT REVIEW12-12-2025KHA1ISSUED FOR PERMIT REVIEWKHA2ISSUED FOR PERMIT REVIEWKHA3ISSUED FOR PERMIT REVIEWKHA05-11-202606-29-202608-18-2026COOPER LAW FIRM474 WANDO PARK BLVD,SUITE 105MT. PLEASANT, SC 29464PHONE: 843.881.5413
MAYBANK SUBDIVISIONCONCEPT PLANMAYBANK HIGHWAY, JOHNS ISLAND, SC 29455
SCALE:DRAWN BY:DESIGNED BY:CHECKED BY:
AS SHOWN
QRDGCC
KHA
KHA PROJECT NO.01827810002/09/2026DATE:
C2-15ACCESSIBLE ROUTE PLAN
NORTH
ADA NOTES:1.ALL AMENITIES TO BE ADA COMPLIANT.2.DOORS TO OPEN ACCESSIBLY.3.ENTRANCES THAT ARE NOT ADA ACCESSIBLE ARE TO CONTAIN SIGNAGE.REFERENCE ARCHITECTURE PLANS FOR DETAILS.4.60% OF ALL ENTRANCES TO BE ACCESSIBLE.5.ALL HOUSING DEVELOPMENT MUST MEET ALL THE FAIR HOUSINGREQUIREMENTS FOR ACCESSIBLE UNITS THE PUBLIC RIGHT-OF-WAY MUSTREMAIN ADA COMPLIANT DURING CONSTRUCTION OR AN ALTERNATIVE ROUTEMUST BE PROVIDED.6.IT IS THE OWNER’S RESPONSIBILITY TO REPAIR ALL DAMAGED SIDEWALKS TOREINSTATE AN ADA ACCESSIBLE ROUTE.7.ALL CHARLESTON HOUSING AUTHORITY PROJECTS MUST MEET ADA TITLE IIREQUIREMENTS OF ACCESS TO PROGRAMS.8.ALL CHARLESTON HOUSING AUTHORITY PROJECTS ARE SUBJECT TO ADAINSPECTION BY THE CITY’S ADA COORDINATOR PRIOR TO THE ISSUANCE OF ACERTIFICATE OF OCCUPANCY TO ASSURE COMPLIANCE.9.THE CITY ADA COORDINATOR MAY CONDUCT ANNUAL INSPECTIONS ONCHARLESTON HOUSING AUTHORITY PROPERTIES TO ASSURE CONTINUED ADACOMPLIANCE.10.PUBLIC TRANSPORTATION CONNECTIONS/ BUS STOPS: IF THERE IS A BUS STOPIN THE RIGHT-OF-WAY AS YOU BEGIN A PROJECT, IT MUST BE THERE WHENYOU’VE COMPLETED THE PROJECT.11.ALL AMENITIES MUST BE ADA COMPLIANT.12.USPS SERVICE (PERHAPS A KIOSK) MUST BE ADA COMPLIANT— (BE AWARE OFREACH RANGES.)
PROPOSED ADA ROUTE
PROPERTY LINEADA ROUTE PLAN LEGEND:
SOUTHWICK DRIVE (S-1153) SCDOT MAINTAINED 66' R/W
MAYBANK HWY (SC-700) SCDOT MAINTAINED 60' R/W
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
X
X
X
X
X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X
W W W W W W W W W W W W W W W W W
FMFMFMFMFMFMFMFM
60" LIVE OAK(B)
42" WATER OAK(D)
4/13/13" MAPLE(D)
2/5/8/10/10" MAPLE(D)
18/23" LIVE OAK(C)
3/5/18" WATER OAK(D)
31" WATER OAK(C)
42" LIVE OAK(C)
14/16" WATER OAK(NON GRADED)
10/16" MAPLE(D)
Aerial Fire TruckAerial Fire Truck
Aerial Fire Truck
Aerial Fire Truck
Aerial Fire Truck
Aerial Fire Truck
Aerial Fire Truck
8W
8W8W 8W
8W
8W
8W 8W8W
FIRE HYDRANT
FIRE HYDRANT
FIRE HYDRANT
FIRE HYDRANT
FIRE HYDRANT
INFILTRATIONBASIN 3
INFILTRATIONBASIN 2
INFILTRATIONBASIN 1
INFILTRATIONBASIN 5
LOT 62
LOT 61
LOT 60
LOT 59
LOT 58
LOT 57
LOT 56
LOT 55
LOT 54
LOT 53
LOT 52
LOT 51
LOT 50
LOT 49
LOT 48
LOT 47
LOT 46
LOT 45
LOT 44
LOT 43
LOT 42
LOT 41
LOT 40
LOT 39
LOT 38
LOT 37
LOT 36
LOT 35
LOT 34
LOT 33
LOT 32LOT 31LOT 30LOT 29LOT 28LOT 27LOT 26LOT 25LOT 24LOT 23
LOT 22LOT 21LOT 20LOT 19LOT 18LOT 17LOT 16LOT 15LOT 14LOT 13LOT 12LOT 11LOT 10LOT 9LOT 8LOT 7LOT 6LOT 5LOT 4LOT 3LOT 2LOT 1
50' CITY OF CHARLESTONMAINTAINED ROW
>
> > > >>>
>
>
>
>
>
>>
332' HOSE LAY LENGTH
335' HOSE LAY LENGTH
> > > >
>>>
327' HOSE LAY LENGTH
>>>>
> > > >
>
178' HOSE LAY LENGTH
> > > >
>
>>>>>
>
263' HOSE LAY LENGTH230' HOSE LAY LENGTH218' HOSE LAY LENGTH
INFILTRATIONBASIN 4
SHEET NUMBERPROJECT:
TITLE:
No. DATEBY
Drawing name: K:\CHA_LDEV\018278 Cooper Law Firm\100 Maybank PUD\02 - DWG\PlanSheets\C2-30 - FIRE PROTECTION PLAN.dwg C2-30 FIRE PROTECTION PLAN Aug 19, 2026 11:29am by: Devin.FrankThis document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose and client for which it was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Kimley-Horn and Associates, Inc. shall be without liability to Kimley-Horn and Associates, Inc.
PRELIMINARY: NOT FOR CONSTRUCTION
© 2026 KIMLEY-HORN AND ASSOCIATES, INC.1080 MORRISON DRIVE, SUITE 240CHARLESTON, SOUTH CAROLINA 29403PHONE (843) 737-6390WWW.KIMLEY-HORN.COM
CLIENT:
CERTIFICATE OF AUTHORIZATIONAND
No. C00166INC
KIMLEY-HORNASSOCIATES,
TUSO NILAHCROA
PRELIMINARYNOT FOR CONSTRUCTION
REVISIONS0ISSUED FOR PERMIT REVIEW12-12-2025KHA1ISSUED FOR PERMIT REVIEWKHA2ISSUED FOR PERMIT REVIEWKHA3ISSUED FOR PERMIT REVIEWKHA05-11-202606-29-202608-18-2026COOPER LAW FIRM474 WANDO PARK BLVD,SUITE 105MT. PLEASANT, SC 29464PHONE: 843.881.5413
MAYBANK SUBDIVISIONCONCEPT PLANMAYBANK HIGHWAY, JOHNS ISLAND, SC 29455
SCALE:DRAWN BY:DESIGNED BY:CHECKED BY:
AS SHOWN
QRDGCC
KHA
KHA PROJECT NO.01827810002/09/2026DATE:
C2-30FIRE PROTECTIONPLAN
NORTH
FIRE HYDRANTFDC, REMOTE
500' HOSE LAY LENGTH
SITE PLAN LEGEND:
22.007.00
43.00
:33.3Steering Angle
8.508.506.0
Aerial Fire Truckfeet:::WidthTrackLock to Lock Time
FDC, WALL MOUNTED
DESIGN FIRE TRUCK:
123
1.A MINIMUM FIRE FLOW OF 1,000 GPM AND RESIDUALPRESSURE OF 20 PSI SHALL BE PROVIDED AND MAINTAINEDFOR ALL PROPOSED WATER MAINS IN ACCORDANCE WITH ST.JOHNS WATER STANDARDS AND SPECIFICATIONS.2.A FIRE FLOW TEST SHALL BE CONDUCTED AT THE NEARESTEXISTING ST. JOHNS WATER FIRE HYDRANT AND SUBMITTEDTO ST. JOHNS WATER WITHIN ONE (1) YEAR PRIOR TOISSUANCE OF THE PERMIT TO CONSTRUCT.
FIRE PROTECTION NOTES:
FIRE APPARATUS LANE (MIN 24' WIDE)
NOTES:1.TYPE V BUILDING CONSTRUCTION NOT PERMITTED IN CITY OF CHARLESTONFIRE DISTRICTS.2.BUILDING TYPES AND SQUARE FOOTAGE SHALL BE REVIEWED AND APPROVEDTHROUGH REQUIRED CITY OF CHARLESTON PROCESSES.3.STREET NAMES AND ADDRESSES TO BE APPROVED THROUGH CITY OFCHARLESTON REQUIRED REVIEWS.4.Q20 FIRE FLOW AVAILABLE - 2698 GPMFIRE FLOW REQUIRED BY BUILDING TYPE91024 SF OF DEVELOPMENTGROUP R-3 AND R-4 - 1625 GPM4.STREET ADDRESS SHALL BE POSTED IN NOT LESS THAN 4-INCHLETTERS/NUMBERS (RECOMMEND 6 INCH) IN A MANNER THAT IS PLAINLYVISIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY AS REQUIREDBY SCFC SECTION 505.1. ADDRESS NUMBERS SHALL BE ARABIC NUMBERS ORALPHABETICAL LETTERS. NUMBERS SHALL NOT BE SPELLED OUT. INDIVIDUALSUITES OR SUBDIVISION WITHIN THE BUILDING SHALL INCLUDE THE SUITEDESIGNATION IN A 4-INCH MINIMUM LETTER/NUMBER. STREET MARQUEESSHALL INCLUDE THE SITE ADDRESS
W W W W W W W W W W W W W W W W W
FMFMFMFMFMFMFMFM
60" LIVE OAK(B)
42" WATER OAK(D)
4/13/13" MAPLE(D)
2/5/8/10/10" MAPLE(D)
18/23" LIVE OAK(C)
3/5/18" WATER OAK(D)
31" WATER OAK(C)
42" LIVE OAK(C)
14/16" WATER OAK(NON GRADED)
10/16" MAPLE(D)
SOUTHWICK DRIVE (S-1153) SCDOT MAINTAINED 66' R/W
MAYBANK HWY (SC-700) SCDOT MAINTAINED 60' R/W
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
X
X
X
X
X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X
SS
SS
SS
SS
SS
SS SS SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS
SSSSSSSSSSSSSS
SS SS SS
SS
SS SS SS SS SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS SS SS SS
SS
SS SS SS SS
SS SS SS SS
SS SS SS SS
8W
8W8W 8W
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
8W
8W
8W 8W
SS
SSSS SS
SS SS
SS
SSSS SS
SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS
8W
A.7 - CB-SCDOT TYPE 1
A.6 - CB-SCDOT TYPE 1A.5 - CB-SCDOT TYPE 1
B.7.2 - CB-SCDOT TYPE 1
B.11 - CB-SCDOT TYPE 16
B.11.1 - CB-SCDOT TYPE 1
B.12 - CB-SCDOT TYPE 16
B.13 - CB-SCDOT TYPE 16
A.3 - CB-SCDOT TYPE 1
B.6 - CB-SCDOT TYPE 1B.3 - CB-SCDOT TYPE 1
B.1 - CB-SCDOT TYPE 16
D.1 - CB-SCDOT TYPE 1
D.2 - CB-SCDOT TYPE 1
C.2 - CB-SCDOT TYPE 16
18" RCP18" RCP
18" RCP
18" RCP18" RCP 18" RCP 18" RCP
18" RCP
24" RCP
18" RCP
C.0.2 - HW - 30"18" RCPC.0.1 - OCS-4x4
D.0 - FES - 18"18" RCP
C.1 - CB-SCDOT TYPE 1
18" RCPC.0 - FES - 18"
C.5 - CB-SCDOT TYPE 16
C.4 - CB-SCDOT TYPE 16
A.0 - FES - 18" 18" RCP
A.4 - MANHOLE
B.10 - MANHOLE
B.0.1 - OCS-4x418" RCPB.0.2 - HW - 30"
B.0 - FES - 18"
24" RCP
24" RCPA.0.1 - OCS-4x4
A.0.2 - HW - 24"
18" RCP
A.2 - CB-SCDOT TYPE 1
B.5 - CB-SCDOT TYPE 1B.4 - CB-SCDOT TYPE 1
PROPOSED 20' CWSSEWER EASEMENT
10'
20' MAINTENANCE SHELFAND ACCESS EASEMENT
20'
20' DRAINAGE ANDACCESS EASEMENT
20'
10' MAINTENANCE SHELFAND ACCESS EASEMENT
15'
15' MAINTENANCE SHELFAND ACCESS EASEMENT
B.7.1 - CB-SCDOT TYPE 16
18" RCP
18" RCP18" RCP
24" RCP24" RCP
24" RCP
24" RCP
18" RCP
18" RCP
2122
23
21222324
252525
27
0.66%
0.78% 0.51%
3:1
PROPERTY LINE (TYP)
22
23
24
26
26
3:1
LOT 62
LOT 61
LOT 60
LOT 59
LOT 58
LOT 57
LOT 56
LOT 55
LOT 54
LOT 53
LOT 52
LOT 51
LOT 50
LOT 49
LOT 48
LOT 47
LOT 46
LOT 45
LOT 44
LOT 43
LOT 42
LOT 41
LOT 40
LOT 39
LOT 38
LOT 37
LOT 36
LOT 35
LOT 34
LOT 33
LOT 32LOT 31LOT 30LOT 29LOT 28LOT 27LOT 26LOT 25LOT 24LOT 23
LOT 22LOT 21LOT 20LOT 19LOT 18LOT 17LOT 16LOT 15LOT 14LOT 13LOT 12LOT 11LOT 10LOT 9LOT 8LOT 7LOT 6LOT 5LOT 4LOT 3LOT 2LOT 1
FPE: 27.5FPE: 27.4FPE: 28.1FPE: 28.7 FPE: 29.4FPE: 29.4
FPE: 26.4
FPE: 26.8
FPE: 26.6
FPE: 26.4
FPE: 26.2
FPE: 25.5
FPE: 25.2
FPE: 25.0
FPE: 25.2
FPE: 25.4
FPE: 25.6
FPE: 25.6
FPE: 22.4
FPE: 22.8
FPE: 23.3
FPE: 24.0
FPE: 24.8
FPE: 25.6
FPE: 25.6
FPE: 25.5
FPE: 25.3
FPE: 25.1
FPE: 25.1
FPE: 25.3
FPE: 25.5
FPE: 25.7
FPE: 25.9
FPE: 26.1
FPE: 26.3
FPE: 26.5
10'
2' DEPTH V SHAPE GRASSED SWALEAND 30' CITY OF CHARLESTONDRAINAGE EASEMENT
SEA ISLAND HABITATFOR HUMANITYRESTORE
SEA ISLAND HABITATFOR HUMANITYRESTORE PARKING LOT
INFILTRATIONBASIN 3
INFILTRATIONBASIN 2
INFILTRATIONBASIN 1
INFILTRATIONBASIN 4
SEA ISLAND HABITATFOR HUMANITYRESTORE
SEA ISLAND HABITATFOR HUMANITYRESTORE PARKING LOT
PRESERVEDWETLAND
PRESERVEDWETLAND
POCKETPARK
PARK
POCKETPARK
EXISTINGWET POND
INFILTRATIONBASIN 5
0.69%
0.67%
F.1 - Landscape Yard Inlet - Square
12" RCP
F.0 - FES - 12"
0.71%0.83%
36" RCP
G.4 - HW - 18"G.2 - HW - 18"
G.0 - HW - 18"
18" RCP
18" RCP
18" RCP18" RCP
G.5 - FES - 18"G.3 - FES - 18"G.1 - FES - 18"
18" RCP
23232424 2526
18" RCP
C.3 - MANHOLE
6:1
0.68%
B.2 - CB-SCDOT TYPE 1
24" RCP
202021
212223
2223
10' 10' MAINTENANCE SHELFAND ACCESS EASEMENT
D.0.1 - OCS-4x4
30" RCPD.0.2 - FES - 30"
0.50%
1.00%
212223
222324
25
26
232425
2021
24
22
23
24
20212223
212223
22232420212223
0.52%
0.52%
212223232324252525
242425 25
27282929
29
2627
2828
232425
2122232425
10.00%
4.20% 22232424
VEGETATED FILTER STRIP
2425
25
232425
23
PROPOSED 30' CITY OFCHARLESTONDRAINAGE EASEMENT
PROPOSED 30' CITYOF CHARLESTONDRAINAGE EASEMENT
12:1
VEGETATED FILTER STRIP
1920
22
18" RCP18" RCP
B.8 - CB-SCDOT TYPE 16
B.9 - CB-SCDOT TYPE 16
B.1.2 - CB-SCDOT TYPE 1618" RCPB.1.1 - CB-SCDOT TYPE 16
18" RCP
3'X14' CONCRETE BOX CULVERT
± 790 LFPROPOSED RETAININGWALL. MAX HEIGHT: ±3.5'
± 700 LFPROPOSED RETAININGWALL. MAX HEIGHT: ±4'
± 220 LFPROPOSED RETAININGWALL. MAX HEIGHT: 1.5'
2123
H.1 - FES - 18"H.0 - FES - 18"
24" RCPB.7 - CB-SCDOT TYPE 16
24
24
25
25
I.1 - FES - 36"I.0 - FES - 36"
232322232425
3:13:1 25
26
22232425
2626
26
26
26
27
27
2727
27
1919 20
20
21
21
21
21222324
25
25
25 26
26
2627
24 25 2627
28 29
EMERGENCY SPILLWAY
EMERGENCY SPILLWAY
EMERGENCY SPILLWAY
EMERGENCY SPILLWAY
EMERGENCY SPILLWAY
SHEET NUMBERPROJECT:
TITLE:
No. DATEBY
Drawing name: K:\CHA_LDEV\018278 Cooper Law Firm\100 Maybank PUD\02 - DWG\PlanSheets\C3-00 - GRADING AND DRAINAGE PLAN.dwg C3-00 GRADING AND DRAINAGE PLAN Aug 19, 2026 3:25pm by: Devin.FrankThis document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose and client for which it was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Kimley-Horn and Associates, Inc. shall be without liability to Kimley-Horn and Associates, Inc.
PRELIMINARY: NOT FOR CONSTRUCTION
© 2026 KIMLEY-HORN AND ASSOCIATES, INC.1080 MORRISON DRIVE, SUITE 240CHARLESTON, SOUTH CAROLINA 29403PHONE (843) 737-6390WWW.KIMLEY-HORN.COM
CLIENT:
CERTIFICATE OF AUTHORIZATIONAND
No. C00166INC
KIMLEY-HORNASSOCIATES,
TUSO NILAHCROA
PRELIMINARYNOT FOR CONSTRUCTION
REVISIONS0ISSUED FOR PERMIT REVIEW12-12-2025KHA1ISSUED FOR PERMIT REVIEWKHA2ISSUED FOR PERMIT REVIEWKHA3ISSUED FOR PERMIT REVIEWKHA05-11-202606-29-202608-18-2026COOPER LAW FIRM474 WANDO PARK BLVD,SUITE 105MT. PLEASANT, SC 29464PHONE: 843.881.5413
MAYBANK SUBDIVISIONCONCEPT PLANMAYBANK HIGHWAY, JOHNS ISLAND, SC 29455
SCALE:DRAWN BY:DESIGNED BY:CHECKED BY:
AS SHOWN
QRDGCC
KHA
KHA PROJECT NO.01827810002/09/2026DATE:
Xref ..\References\xBORDER.dwg
NORTH C3-00GRADING ANDDRAINAGE PLAN
GRADING & DRAINAGE NOTES:1.SITE AREA: 13.47 ACRESDISTURBED AREA: 12.3 ACRES2.CRITICAL SPOT GRADES ARE TO PAVEMENT GRADE UNLESSOTHERWISE NOTED.3.CONTRACTOR SHALL CONSTRUCT ALL SIDEWALKS ANDCROSSWALKS WITH A 2.00% MAXIMUM CROSS SLOPE AND A5.00% MAXIMUM RUNNING SLOPE, UNLESS NOTED AS A RAMP.GRADES WITHIN ADA HANDICAP PARKING AREAS NOT TOEXCEED A 2.00% MAXIMUM SLOPE IN ANY DIRECTION.4.CONTRACTOR SHALL TAKE FIELD SLOPE MEASUREMENTS ONFINISHED SUBGRADE AND FORM BOARDS PRIOR TO PLACINGPAVEMENT TO VERIFY THAT ADA SLOPE REQUIREMENTS AREPROVIDED. CONTRACTOR SHALL CONTACT ENGINEER PRIOR TOPAVING IF ANY EXCESSIVE SLOPES ARE ENCOUNTERED. NOCONTRACTOR CHANGE ORDERS WILL BE ACCEPTED FOR ADASLOPE COMPLIANCE ISSUES5.ALL ROOF DRAIN PIPING SHALL BE PVC UNLESS OTHERWISENOTED.6.ALL ROOF DRAIN CLEANOUTS IN PAVED AREAS SHALL HAVE ABRASS CAP SET FLUSH WITH THE PROPOSED GRADE.7.ALL PIPE LENGTHS SPECIFIED IN THESE PLANS ARE THEHORIZONTAL DISTANCE AND ARE SHOWN FOR REFERENCEONLY. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TODETERMINE ACTUAL LENGTHS BASED ON PROPOSED PIPESLOPE. PIPE LENGTHS IN PLANS ARE MEASURED FROM CENTEROF STRUCTURE TO CENTER OF STRUCTURE UNLESS OTHERWISENOTED.8.THIS PROJECT DOES NOT LIE WITHIN A 100 YEAR FLOOD HAZARDZONE AS DEFINED BY THE F.E.M.A. "FLOOD HAZARD BOUNDARYMAP" COMMUNITY PANEL NUMBER 45019C0655K, DATED01/29/2021.9.UTILITIES MAY EXIST WHICH ARE NOT SHOWN ON THE PLANS.THE CONTRACTOR SHALL BE RESPONSIBLE FOR CONTACTINGALL UTILITY COMPANIES HAVING UTILITIES WITHIN OR ADJACENTTO THE WORK AREA. THE CONTRACTOR SHALL HAVE THEUTILITIES FIELD LOCATED AND COORDINATE WITH THE UTILITYCOMPANIES TO HAVE CONFLICTS RELOCATED WHENNECESSARY OR ADAPTED FOR TIE-INS.10.CONTRACTOR TO FIELD VERIFY EXISTING INVERT FOR SANITARYSEWER AND STORM DRAINAGE SERVICE CONNECTIONS PRIORTO CONSTRUCTION. CONTRACTOR SHALL NOTIFY ENGINEER OFDISCREPANCY PRIOR TO PROCEEDING.11.NO GRADED SLOPE SHALL EXCEED 3H:1V12.ALL WALLS GREATER THAN 30" IN HEIGHT SHALL BE DESIGNEDAND PERMITTED BY AN ENGINEER LICENSED IN THE STATE OFSOUTH CAROLINA.13.ALL WALLS GREATER THAN 30" IN HEIGHT SHALL HAVE FALLPROTECTION THROUGH FENCING OR HANDRAIL AT A MINIMUMOF 42" TALL. REFERENCE LANDSCAPE PLANS FOR DETAILS.14.THE INFILTRATION FOR THE STORMWATER SYSTEM IS BASED ONIN-SITU TESTING BY GEOTECHNICAL ENGINEER. THE SYSTEM ISBASED ON OBTAINING INFILTRATION RATES SIMILAR TO THETESTED VALUES PRE-CONSTRUCTION. AS SUCH, THE AREASWHERE STORMWATER IS DIRECTED TO INFILTRATE ARE TOREMAIN RESIDUAL SOILS AND COMPACTION IS TO BE LIMITED TOENSURE THE SOIL CHARACTERISTICS CONTINUE TO FUNCTIONAS TESTED PRE-CONSTRUCTION. IF THESE AREAS AREDISTURBED, COMPACTED, OR FILLED, THE ENGINEER IS TO BENOTIFIED AS ADDITIONAL TESTING AND COORDINATION WOULDBE REQUIRED TO ENSURE THE PREVIOUSLY RECORDEDINFILTRATION RATES CAN BE ACHIEVED.15.ALL EASEMENTS FOR PIPES, BMPS, ACCESS, MAINTENANCE, ETC.SHALL MEET THE CITY OF CHARLESTON MINIMUM WIDTHREQUIREMENTS OUTLINED IN THE CITY OF CHARLESTONSTORMWATER MANUAL.16. ALL INFILTRATION BASINS SHALL HAVE A MINIMUM 0.5% BOTTOMSLOPE TO ENSURE POSITIVE DRAINAGE TO OUTFALL.
2021
20.00
2021
HP:20.00
EXISTING MAJOR CONTOURGRADING LEGEND:
EXISTING MINOR CONTOURPROPOSED MAJOR CONTOURPROPOSED MINOR CONTOUR
PROPOSED SPOT GRADEPROPOSED TOP GRADE AT WALLPROPOSED BOTTOM GRADE AT WALLPROPOSED TOP OF STAIR GRADEPROPOSED BOTTOM OF STAIR GRADEPROPOSED HIGH POINT GRADE
PROPOSED TOP OF CURB GRADEPROPOSED BOTTOM OF CURB GRADE
BG:20.00TG:20.00
PROPOSED LOW POINT GRADE
TS:20.00 BS:20.00
TC:20.00 BC:20.00
DRAINAGE FLOW ARROW
PROPOSED STORM PIPE4.66%
LP:20.00
GICB 4' X 4' GRATE INLETTYPE 18 CATCH BASIN
MH MANHOLE
OCS OUTLET CONTROL STRUCTUREFES FLARED END SECTION
PROPOSED FINISHED PAD ELEVATIONFPE:20.00
PROPOSED RIPRAP
0GRAPHIC SCALE IN FEET
60
3060 120
PROTECTIVE REAR SLOPESIDE SLOPESIDE SWALEPROTECTIVE FRONT SLOPEPARKWAY SLOPESTREET
SIDE SWALE
LOT GRADING TYPE BDRAINAGE BOTH TO STREET & REAR LOT LINE
CONCEPTUAL EARTHWORKRAW EARTHWORKCUT: ± 2,574.80 CYFILL: ± 41,234.80 CYRIGHTS-OF-WAYCUT: ± 8,514.67 CYADJUSTED EARTHWORKNET: ± 30,145.33 CY
W W W W W W W W W W W W W W W W W
FMFMFMFMFMFMFMFM
60" LIVE OAK(B)
42" WATER OAK(D)
4/13/13" MAPLE(D)
2/5/8/10/10" MAPLE(D)
18/23" LIVE OAK(C)
3/5/18" WATER OAK(D)
31" WATER OAK(C)
42" LIVE OAK(C)
14/16" WATER OAK(NON GRADED)
10/16" MAPLE(D)
SOUTHWICK DRIVE (S-1153) SCDOT MAINTAINED 66' R/W
MAYBANK HWY (SC-700) SCDOT MAINTAINED 60' R/W
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
X
X
X
X
X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X
SS
SS
SS
SS
SS
SS SS SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS
SSSSSSSSSSSSSS
SS SS SS
SS
SS SS SS SS SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS SS SS SS
SS
SS SS SS SS
SS SS SS SS
SS SS SS SS
8W
8W8W 8W
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
8W
8W
8W 8W
SS
SSSS SS
SS SS
SS
SSSS SS
SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS
8W
PROPOSED 8" WATER MAIN (TYP.)
TAP INTO EXISTING16" WATER MAIN
8"X6" TEE
FIRE HYDRANT
8"X6" TEE
FIRE HYDRANT
8"X6" TEE
FIRE HYDRANT8" WATER MAIN(TYP.) 8"X6" TEEFIRE HYDRANT
8" PVC GRAVITYSEWER (TYP.)
8" PVC GRAVITYSEWER (TYP.)
8"X6" TEE
FIRE HYDRANT
8" PVC GRAVITY SEWER (TYP.)
10' G.U.E.
10' G.U.E.
10' G.U.E.
20
PROPOSED 20' CWSSEWER EASEMENT
PROPOSED SEWER TO TIE INTOEXISTING CHARLESTON WATERSYSTEM SEWER LIFT STATION
INFILTRATIONBASIN 1
INFILTRATIONBASIN 2 INFILTRATIONBASIN 3
INFILTRATIONBASIN 4
BLOW OFF VALVE
PROPERTY LINE (TYP)
LOT 62
LOT 61
LOT 60
LOT 59
LOT 58
LOT 57
LOT 56
LOT 55
LOT 54
LOT 53
LOT 52
LOT 51
LOT 50
LOT 49
LOT 48
LOT 47
LOT 46
LOT 45
LOT 44
LOT 43
LOT 42
LOT 41
LOT 40
LOT 39
LOT 38
LOT 37
LOT 36
LOT 35
LOT 34
LOT 33
LOT 32LOT 31LOT 30LOT 29
LOT 28LOT 27LOT 26LOT 25LOT 24LOT 23LOT 22LOT 21LOT 20LOT 19LOT 18LOT 17
LOT 16LOT 15LOT 14LOT 13LOT 12LOT 11
LOT 10LOT 9LOT 8LOT 7LOT 6LOT 5
LOT 4LOT 3LOT 2LOT 1
INFILTRATIONBASIN 5
SHEET NUMBERPROJECT:
TITLE:
No. DATEBY
Drawing name: K:\CHA_LDEV\018278 Cooper Law Firm\100 Maybank PUD\02 - DWG\PlanSheets\C4-00 - UTILITY PLAN.dwg C4-00 UTILITY PLAN Aug 19, 2026 2:10pm by: Devin.FrankThis document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose and client for which it was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Kimley-Horn and Associates, Inc. shall be without liability to Kimley-Horn and Associates, Inc.
PRELIMINARY: NOT FOR CONSTRUCTION
© 2026 KIMLEY-HORN AND ASSOCIATES, INC.1080 MORRISON DRIVE, SUITE 240CHARLESTON, SOUTH CAROLINA 29403PHONE (843) 737-6390WWW.KIMLEY-HORN.COM
CLIENT:
CERTIFICATE OF AUTHORIZATIONAND
No. C00166INC
KIMLEY-HORNASSOCIATES,
TUSO NILAHCROA
PRELIMINARYNOT FOR CONSTRUCTION
REVISIONS0ISSUED FOR PERMIT REVIEW12-12-2025KHA1ISSUED FOR PERMIT REVIEWKHA2ISSUED FOR PERMIT REVIEWKHA3ISSUED FOR PERMIT REVIEWKHA05-11-202606-29-202608-18-2026COOPER LAW FIRM474 WANDO PARK BLVD,SUITE 105MT. PLEASANT, SC 29464PHONE: 843.881.5413
MAYBANK SUBDIVISIONCONCEPT PLANMAYBANK HIGHWAY, JOHNS ISLAND, SC 29455
SCALE:DRAWN BY:DESIGNED BY:CHECKED BY:
AS SHOWN
KHA PROJECT NO.01827810002/09/2026DATE:
C4-00UTILITY PLAN
UTILITY NOTES
SS
W W W W W
UGP
SS
UGTGAS
PROPOSED WATER LINEPROPOSED ELECTRIC LINEPROPOSED TELEPHONE LINEPROPOSED NATURAL GAS LINE
FIRE DEPARTMENT CONNECTION (FDC)WATER VALVESANITARY SEWER MANHOLEPROPOSED SANITARY SEWER CLEANOUTPROPOSED SANITARY SEWER PIPE
FIRE HYDRANTPOST INDICATOR VALVE (PIV)
WATER CONNECTIONS AND BENDSWATER MAIN TAPPING SLEEVE
UTILITY LEGEND:
1.ALL SANITARY SEWER CLEANOUTS IN PAVED AREAS SHALL HAVE A BRASS CAPSET FLUSH WITH THE PROPOSED GRADE.2.CONTRACTOR SHALL COORDINATE UTILITY CONNECTION AND REROUTINGLOCATIONS WITH APPLICABLE AGENCIES.3.ALL UTILITIES SHALL BE CONSTRUCTED IN ACCORDANCE WITH CWS AND SAINTJOHNS WATER SANITARY SEWER AND WATER DETAILS AND SPECIFICATIONS.4.ALL PIPE LENGTHS SPECIFIED IN THESE PLANS ARE THE HORIZONTAL DISTANCEAND ARE SHOWN FOR REFERENCE ONLY. IT IS THE RESPONSIBILITY OF THECONTRACTOR TO DETERMINE ACTUAL LENGTHS BASED ON PROPOSED PIPESLOPE. PIPE LENGTHS IN PLANS ARE MEASURED FROM CENTER OF STRUCTURETO CENTER OF STRUCTURE UNLESS OTHERWISE NOTED.5.UTILITIES MAY EXIST WHICH ARE NOT SHOWN ON THE PLANS. THE CONTRACTORSHALL BE RESPONSIBLE FOR CONTACTING ALL UTILITY COMPANIES HAVINGUTILITIES WITHIN OR ADJACENT TO THE WORK AREA. THE CONTRACTOR SHALLHAVE THE UTILITIES FIELD LOCATED AND COORDINATE WITH THE UTILITYCOMPANIES TO HAVE CONFLICTS RELOCATED WHEN NECESSARY OR ADAPTEDFOR TIE-INS.6.ALL UTILITY CONNECTIONS END AT 5' OUTSIDE OF THE BUILDING FOOTPRINT.REFER TO ARCHITECTURAL, MECHANICAL, ELECTRICAL, AND PLUMBING PLANSFOR BUILDING LAYOUT AND INTERNAL UTILITY SERVICE.7.ALL ONSITE UTILITIES SHALL BE LOCATED UNDERGROUND.8.CONTRACTOR TO FIELD VERIFY EXISTING INVERT FOR SANITARY SEWERSERVICE CONNECTIONS PRIOR TO CONSTRUCTION. CONTRACTOR SHALL NOTIFYENGINEER OF DISCREPANCY PRIOR TO PROCEEDING.9.CONTRACTOR SHALL BE RESPONSIBLE FOR THE METER VAULT, PIPING,APPURTENANCES, ETC. ASSOCIATED WITH THE WATER METER AND BACKFLOWINSTALLATION. SAINT JOHNS WATER TO PROVIDE THE WATER METER ANDBACKFLOW PREVENTERS UPON PAYMENT OF TAP FEES.10.ALL BACK FLOW PREVENTION DEVICES SHALL BE SCDES APPROVED.11.CONTRACTOR SHALL MAINTAIN 3' OF COVER OVER WATERLINES EXCEPT ASREQUIRED AT STORM AND SANITARY SEWER CROSSINGS. AT CROSSINGSCONTRACTOR SHALL BEND THE WATERLINE OVER THE CROSSING UTILIZINGMECHANICAL, RESTRAINED JOINT PIPING WHILE MAINTAINING A MINIMUM OF 1' OFSEPARATION BETWEEN THE PIPES. PIPE CROSSING SHALL BE ENCASED INCONCRETE 5' TO EITHER SIDE.12.WATER MAINS 4" - 12" IN DIAMETER SHALL BE C900 CLASS 235 (DR18) PVC.SMALLER THAN 4" SHALL BE SCHEDULE 80 PVC.13.SANITARY SEWER LINES SHALL BE SDR 26 PVC.14.REFERENCE SHEET C0-01 FOR CWS AND SAINT JOHNS WATER STANDARD WATERAND SEWER NOTES.15.REFERENCE SANITARY SEWER AND STORM PIPE PROFILE SHEETS FORPROPOSED UTILITY CROSSING ELEVATIONS AND SEPARATIONS. CONTRACTORSHALL PROVIDE RESTRAINED JOINT VERTICAL BENDS ON THE WATERLINES ASNECESSARY TO MAINTAIN ADEQUATE SEPARATION. ENSURE ALL WATER LINEBENDS ARE ADEQUATELY DOCUMENTED ON THE AS-BUILT PLANS.16.AT CONNECTIONS, CONTRACTOR TO PROVIDE TEMPORARY BFP AND WATERMETER. SEE DETAIL. ALL OTHER LOCATIONS, 3' AIR GAP TO REMAIN UNTIL PTORECEIVED.17.ALL FIRE SPRINKLER LINES ON SITE SHALL BE TESTED AND WITNESSED INACCORDANCE WITH SCDES AND SAINT JOHNS WATER REQUIREMENTS.
NORTH
Source: City of Charleston website. First collected Oct 23, 2026.