RecordWell Data

Planning Commission — Agenda Packet

Pickens County · Pickens County · Pickens County Council · meeting of Dec 8, 2025 · Agenda packets

Open the original document More from Pickens County

Text

Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.

December 2025 LU-25-0007 Ridge at Perry Three APRIL 2024 Applications for Land Use and Subdivision Review Hearings Thank you for your interest in Pickens County, South Carolina. This packet includes the necessary documents for Land Use Reviews to be heard by the Pickens County Planning Commission. Should you need further assistance, please feel free to contact a member of the Planning Staff between the hours of 8:00am and 4:30pm, Monday through Friday at (864) 898-5956. APRIL 2024 This institution is an equal opportunity provider and employer. If you wish to file a Civil Rights program complaint of discrimination, complete the USDA Program Discrimination Complaint Form, found online at http://www.ascr.usda.gov/complaint_filing_cust.html, or at any USDA office, or call (866) 632-9992 to request the form. You may also write a letter containing all of the information requested in the form. Send your completed complaint form or letter to us by mail at U.S. Department of Agriculture, Director, Office of Adjudication, 1400 Independence Avenue, S.W., Washington, D.C. 20250-9410, by fax (202) 690-7442 or email at program.intake@usda.gov. APRIL 2024 Community & tourism development AIRPORT • BUILDING CODES • PLANNING • STORMWATER MANAGEMENT • ENVIRONMENTAL ENFORCEMENT • PARKS • MUSEUM 222 MCDANIEL AVENUE, B-10 • PICKENS, SC 29671 • 864.898.5950 • WWW.PICKENSCOUNTYSC.COM APPLICATION FOR: □ Land Use Review /Subdivision Review □ Subdivision Variance Case No.: _________ - _________ - _________ Note to Applicant: All applications must be typed or legibly printed and all entries must be completed on all the required application forms. If you are uncertain to the applicability of an item, please contact a member of the Planning Staff. Incomplete appl ications or applications submitted after the posted deadlines will be delayed. Name of Applicant ___________________________________________________________________________ Mailing Address _____________________________________________________________________________ Telephone ____________Email_ _____________ Applicant is the: Owner’s Agent _________________ Property Owner __________________ Property Owner(s) of Record___________________________________________________________________ Mailing Address _____________________________________________________________________________ Telephone ____________Email_ _____________ Authorized Representative_____________________________________________________________________ Mailing Address _____________________________________________________________________________ Telephone ____________Email_ ___________ Address/Location of Property ___________________________________________________________________ Existing Land Use __________________________Proposed Land Use _________________________________ Tax Map Number(s) __________________________________________________________________________ Total Size of Project (acres) _______________ Number of Lots ________________________ Utilities: Proposed Water Source: Wells Public Water Water District: _______________________ Proposed Sewer: Onsite Septic Public Sewer Sewer District: _______________ x APRIL 2024 Pickens County, South Carolina Attachment A LAND USE REVIEW Standards of Land Use Approval Consideration In consideration of a land use permit, the Planning Commission shall consider factors relevant in balancing the interest in promoting the public health, safety, and general welfare against the right of the individual to the unrestricted use of property and shall specifically consider the following objective criteria. Due weight or priority shall be given to those factors that are appropriate to the circumstances of each proposal. Please respond to the following standards in the space provided or you may use an attachment as necessary: (A) Is the proposed use consistent with other uses in the area or the general development patterns occurring in the area? ______________________________________________________________________________________________________________________________________ ______________________________________________________________________________________________________________________________________ ______________________________________________________________________________________________________________________________________ (B) Will the proposed use not adversely affect the existing use or usability of adjacent or nearby property? _____________________________________________________________________________________________________________________________________ _____________________________________________________________________________________________________________________________________ _____________________________________________________________________________________________________________________________________ (C) Is the proposed use compatible with the goals, objectives, purpose and intent of the Comprehensive Plan? _____________________________________________________________________________________________________________________________________ _____________________________________________________________________________________________________________________________________ _____________________________________________________________________________________________________________________________________ (D) Will the proposed use not cause an excessive or burdensome use of public facilities or services, including but not limited to streets, schools, water or sewer utilities, and police or fire protection? _____________________________________________________________________________________________________________________________________ _____________________________________________________________________________________________________________________________________ _____________________________________________________________________________________________________________________________________ (E) Is the property suitable for the proposed use relative to the requirements set forth in this development ordinance such as off -street parking, setbacks, buffers, and access? _____________________________________________________________________________________________________________________________________ _____________________________________________________________________________________________________________________________________ _____________________________________________________________________________________________________________________________________ (F) Does the proposed use reflect a reasonable balance between the promotion of the public health, safety, morality, or general welfare and the right to unrestricted use of property? _____________________________________________________________________________________________________________ _____________________________________________________________________________________________________________ _____________________________________________________________________________________________________________ APRIL 2024 Pickens County, South Carolina Attachment B LAND USE REVIEW Application Checklist The following is a checklist of information required for submission of a Land Use Review application. I ncomplete applications or applications submitted after the deadline will be delayed. _______________ Completed application form _______________ Letter of intent _______________ Sketch Plan (major subdivisions) – 8 copies and one (1) reduction to 8 ½” x 11” _______________ Sketch Plan (for multi-family and non - residential) – 8 copies and one (1) reduction to 8 ½” x 11” _______________ Attachment “A” x x N/A x x In consideration of a land use permit, the Planning Commission shall consider factors relevant in balancing the interest in promoting the public health, safety, and general welfare against the right of the individual to the unrestricted use of property and shall specifically consider the following objective criteria. Due weight or priority shall be given to those factors that are appropriate to the circumstances of each proposal. (A) Is the proposed use consistent with other uses in the area or the general development patterns occurring in the area? The proposed redevelopment of the commercial retail property to multi -family is consistent with the commercial development along Hwy 123 that includes commercial retail, service, restaurants, office space, and multi-family townhomes. (B) Will the proposed use not adversely affect the existing use or usability of adjacent or nearby property? The proposed use will not adversely affect the existing use or usability of adjacent or nearby property. The site will be accessed via Hwy 123. New turn lanes which will improve access to the property across Hwy 123 have been approved by DOT . Appropriate landscaping and riparian buffers are utilized along the property boundary to further reduce impacts to adjacent properties. (C) Is the proposed use compatible with the goals, objectives, purpose and intent of the Comprehensive Plan? The Comprehensive Plan was adopted in May of 2022 and placed this property within a Residential Growth area, but nearly adjacent to the Urban Residenti al area betw een Easley and Greenville . This part of 123 i s designated as a Commercial Gateway Corridor. In 2024 County Council updated the Unified Development Standards Ordinance (USDO) to allow 16 unit per acre density on sewered property along 4 lane divided minor arterials such as 123. This was a hard fought and deliberate choice by Council of where density could appropriately be encouraged within the County. Pickens County, South Carolina Attachment A LAND USE REVIEW Standards of Land Use Approval Consideration The Comprehensive Plan itself describes the non-binding nature of the Character Areas: These descriptions are intended to give an idea of the vision for the future for each area, and to provide guidance to decision makers as they consider development and public investment throughout the country. These descriptions are not intended to direct ly limit or restrict potential land uses or development forms, but rather to guide such uses and approvals according to the overall character of the area. Cedarwood would respectfully suggest that the 2022 Comprehensive Plan has been compromised by the pace of development in Pickens County over the last several years. There is a pressing need for attainable housing for both new and returning families. Cedarwood anticipates that the units will be filled with a mix of young people and young families who cannot yet afford to purchase their own homes. To that extent, housing options such as these are the “seed corn” for the future economic development and socia l fabric of the County. The Planning Staff has determined that the development meets the requirements of the USDO. Therefore it certainly complies with the goals, obje ctives, purpose and intent of the Comprehensive Plan as applied to the current conditions in Pickens County. (D) Will the proposed use not cause an excessive or burdensome use of public facilities or services, including but not limited to streets, schools, water or sewer utilities, and police or fire protection? The multi-family development will not cause an excessive burden to public facilities or services as multi-family is efficient for such facilities that service the area along the Hwy 123 corridor. ReWa approval has been acquired for sanitary sewer. Powdersvi lle Water has provided approval for domestic and fire service demand capacity. The applicant has also reached an agreement with Chief Gibson to support the acquisition of a ladder truck to serve this development and others within the district. (E) Is the property suitable for the proposed use relative to the requirements set forth in this development ordinance such as off-street parking, setbacks, buffers, and access? The development team has ensured compliance with requirements set forth in the UDSO and does not foresee any issues maintaining compliance pertaining to setbacks, off -street parking, buffers, and/or access. (F) Does the proposed use reflect a reasonable balance between the promotion of the public health, safety, morality, or general welfare and the right to unrestricted use of property? The proposed multi -family use addresses the need for residential housing to accommodate the growing population. In conjunction with providing housing, the proposed site will promote public health, safety, morality, and general welfare through amenities such as a walking trail, pool, and clubhouse. SITE DESIGN , INC. CIVIL ENGINEERS ▪ SURVEYORS ▪ LANDSCAPE ARCHITECTS 225 R O C K Y C R E E K R O A D G R E E N V I L L E , S O U T H C A R O L I N A 2 9 6 1 5 8 6 4 . 2 7 1 . 0 4 9 6 w w w . s i t e d e s i g n- i n c . c o m November 3, 2025 Mr. Trad Julian Pickens County Planning Department 222 McDaniel Avenue, B-10 Pickens, SC 29671 Subject: Ridge at Perry Bend Three – Multifamily Development Letter of Intent Dear Mr. Julian, Please see below for the Letter of Intent for the proposed multi-family development in Pickens County: Property Information: • Parcel ID: 5049-15-53-6094 & 5049-15-53-4419 Property Use Statement: • There are two (2) parcels associated with the project. PIN 5049-15-53-6094 is a 19.26 ac parcel with an existing landscape nursery that is unoccupied and PIN 5049-15-53-4419 is a 0.55 ac parcel with an existing commercial retail building that is unoccupied. The two (2) parcels will be recombined and redeveloped for a proposed 288-unit multi-family development with a clubhouse and several amenities. Property size: • The two (2) parcels will be recombined to a +/- 19.8-acre parcel. Land Use Requested: • Multi-family residential Density proposed: • 288 units are proposed for a density of 14.5 units per acre. See conceptual site plan for additional information. Building Size proposed: • The proposed multi-family buildings will have a building area to range from +/-7500 sf to +/-12,000 sf. • The maximum units per floor are 8 units per floor. • Eleven (11) apartment buildings total o Six (6) will be 3/4 story split buildings with 28 units o Five (5) will be 3 story buildings with 24 units S ITE D E S I G N, I NC . CIVIL ENGINEERS • SURVEYORS • LANDSCAPE ARCHITECTS Additional Information: • Municipal sanitary sewer is available through Easley Combined Utilities. ReWa approval has been acquired. • Powdersville Water has provided fire flow analysis results as well as an approval letter. • Josh Young at School District of Pickens County has been contacted and made aware of the proposed development so he and his team can plan for the subsequent growth accordingly. • Any signage related to the proposed development will meet the requirements of Pickens County’s sign ordinance. • The development will meet the requirements of Pickens County for landscape buffers and site landscaping. • There is a wetland along the eastern property line as well as in the southwest corner of the property, as such a 50’ riparian buffer has been provided along both wetlands. No grading will occur in this buffer, but a gravel walking path will be placed that will weave into and out of the buffer along the eastern property line. • Ingress and egress will be accessed via Hwy 123 and will be designed to meet SCDOT requirements. SCDOT has been provided with a traffic impact study and currently has it under review. The TIS will be included in Land Use Application documents for Pickens County review. SCDOT is requiring opposing left turn lanes at the existing median break and a right turn lane into the site. SCDOT denied proposals for a Right-in-Right-out driveway as well as a concrete median between thru traffic and the proposed right turn lane. • An agreement between the developers (Rick Dilsavor and Cedarwood Development, Inc.) and the Billy Gibson (Director of Emergency Services with Pickens County) regarding the fire truck was achieved on 08/28/2025. The parties agreed that Cedarwood would contribute $75,000 towards the fire truck. • Addressing Department will require the main drive to be named, but a road name has not yet been submitted or approved. Sincerely, Craig Winnall, P.E. Site Design, Inc FEV CCC CCCC C CCC CCC CCCC CCC CCC FEV www.sitedesign-inc.com 225 ROCKY CREEK ROAD GREENVILLE, SC 29615 PH: (864)271-0496 CIVIL ENGINEERS - SURVEYORS - LANDSCAPE ARCHITECTS© Know what's below.Call before you dig. SITE DATASITE ADDRESS4215 CALHOUN MEMORIAL HWYEASLEY, SC 29640OWNER/DEVELOPERTHE CEDARWOOD COMPANIES3200 WEST MARKET ST STE 200FAIRLAWN, OH 44333CIVIL ENGINEERSITE DESIGN, INC.225 ROCKY CREEK ROADGREENVILLE, SC 29615ARCHITECTCEDARWOOD ARCHITECTURE, INC.3200 WEST MARKET ST STE 200FAIRLAWN, OH 44333PROPOSED USEMULTI-FAMILY288 UNITSPARCEL ID5049-15-53-6094, 5049-15-53-4419DEVELOPMENT AREANATURAL HERITAGE AREAAMENITY AREA3.96 AC REQUIRED3.97 AC PROVIDEDPARCEL AREA19.8 ACRESSETBACKSFRONT: 20'SIDES: 7'REAR: 10' WETDETENTIONPOND TRASH COMPACTOR MAINTENANCE BLDG #824 UNITS(3 STORY) CLUBHOUSEPOOL/POOL DECKMAIL KIOSK PARKING DATA:MULTIFAMILY RESIDENTIAL: 1.5 SPACE PER 1 BR, 2 SPACE PER 2+ BRAPPROXIMATE 1 BR UNITS = 72; 2+ BR UNITS = 216SPACES REQUIRED: (72 x 1.5) + (216 x 2) = 540 SPACESREGULAR SPACES PROVIDED (9'X20'):470 SPACESCOMPACT SPACES PROVIDED (8.5'X18'):24 SPACESVAN ACCESSIBLE SPACED PROVIDED (18'X18'):24 SPACESGARAGE SPACES PROVIDED:23 SPACESTOTAL SPACES PROVIDED:541 SPACESVEHICULAR DRIVE AREA: 212,343 SFLANDSCAPED AREA REQUIRED:212,343 * 20% = 42,469 SFLANDSCAPED AREA PROVIDED:46,906 SFMAXIMUM COMPACT PARKING ALLOWED:541 SPACES * 30% = 162 SPACESCOMPACT PARKING PERCENT:24 / 541 * 100 = 4.44% EXISTING 3-PHASE OHP(SUBJECT TO DUKEENERGY 20' ROW) EXISTING 3-PHASE OHP(SUBJECT TO DUKEENERGY 20' ROW) BLDG #128 UNITS(3/4 STORY SPLIT) BLDG #228 UNITS(3/4 STORY SPLIT) BLDG #724 UNITS(3 STORY) BLDG #328 UNITS(3/4 STORY SPLIT) BLDG #428 UNITS(3/4 STORYSPLIT) BLDG #528 UNITS(3/4 STORY SPLIT)BLDG #628 UNITS(3/4 STORY SPLIT) BLDG #1024 UNITS(3 STORY) BLDG #1124 UNITS(3 STORY) BLDG #924 UNITS(3 STORY) APPROXIMATE LOCATIONOF PROPOSED GRAVELWALKING TRAIL LAND USE: COMMERCIAL LAND USE: COMMERCIALLAND USE: SINGLEFAMILY RESIDENTIAL LAND USE: SINGLEFAMILY RESIDENTIAL LAND USE: COMMERCIALLAND USE: WAREHOUSE- LIGHT BUFFER: TYPE 1 (20')BUFFER: TYPE 1 (20') BUFFER: TYPE 1 (30')BUFFER: TYPE 1 (30') BUFFER: TYPE 1 (30') BUFFER: TYPE 5 (60') BUFFER: TYPE 5 (35') 20'EMERGENCYFIRE ACCESSWITH GATE ROAD WIDENING ANDTURN LANES TO BECOORDINATED WITHSCDOT - REFER TOSCH3 FOR BLOW UP BUFFER: TYPE 1 (20') DENSITY CALCULATIONS:Property Unit DensityPer UDO Article 3 Section 314(c)(1)a., developments within Development Area "Natural Heritage Area" densityshall not exceed eight (8) units per acre when served by public sewer.Exception 314(c)(1)(a)1.:a) When a property and development is served by and has direct access and frontage onto a four (4)lane, divided, minor arterial as defined in Section 1010(b) of this development ordinance, project densityshall not exceed sixteen (16) units per acre.b) The development must be served by public water and public sewer.c) Design Standards1) All buildings or structures shall utilize a common architectural theme that is consisten throughoutthe development.2) All buildings or structures should be sided entirely of brick, stucco, or stone finish, or paintedwood or fiber cement lap siding (such as Hardiplank).3) No less than twenty percent (20%) of the gross site must be devoted and set aside for therecreation amenities listed in 314(a)(1).Proposed Density: 288 units / 19.8 ac. = 14.5 units per acreFloor Unit DensityPer UDO Article 3 Sectioin 314(c)(1)(b)., no more than four (4) dwelling units per floor may be included withina singular building or structure.Exception 314(c)(1)(b)1.:a) No more than eight (8) units per floor may be included within a singular building or structure whenthe above exception (Sec. 314(c)(1)(a)1.) is used.b) Access to apartment or condominium projects shall be governed by the standards enumerated inSection 309(c) for similar Large Scale Projects. 9.0'20.0' 26.0'24.0' 26.0' GARAGE/STORAGE GARAGE/STORAGE GARAGE/STORAGE VEHICULAR DRIVE AREA LANDSCAPING FOR DRIVE AREA AMENITY AREA FEVFUTURE EV PARKING 50' RIPARIANBUFFER 50' RIPARIANBUFFER 26.0' 26.0' 44.0' 9.0'20.0'18.0'20.0' R11.0' R37.0' N ADAMS CTTURNER HILL RDTURNERPOINTE RD KAY DR US HWY 123SITE GARAGE/STORAGER25.0'29.5'R4.0'R16.0'R37.0' R15.0'R12.0'R4.0' R3.0' R4.0'R15.0' R54.0'R15.0'R15.0'R15.0'R4.0' R5.0' R4.0' 26.0' 26.0'26.0' 26.0' 26.0'26.0'24.0' 26.0' CCOMPACT PARKING SPACE (8.5' X 18') SITE WALL (TYP.) SITE WALL (TYP.) 10' INTERIOR WALL ONBUILDINGS WITH 3/4STORY SPLIT (TYP.) 10' INTERIOR WALL ONBUILDINGS WITH 3/4STORY SPLIT (TYP.) APPROXIMATE LOCATIONOF PROPOSED GRAVELWALKING TRAIL APPROXIMATE LOCATIONOF PROPOSED GRAVELWALKING TRAIL 25.0' EXISTINGSEWER EASMENT 20.0' PRESCRIPTIVEDUKE ROW FEV CCC CCCC C CCC CCC CCCC CCC CCC FEV www.sitedesign-inc.com 225 ROCKY CREEK ROAD GREENVILLE, SC 29615 PH: (864)271-0496 CIVIL ENGINEERS - SURVEYORS - LANDSCAPE ARCHITECTS© Know what's below.Call before you dig. SITE DATASITE ADDRESS4215 CALHOUN MEMORIAL HWYEASLEY, SC 29640OWNER/DEVELOPERTHE CEDARWOOD COMPANIES3200 WEST MARKET ST STE 200FAIRLAWN, OH 44333CIVIL ENGINEERSITE DESIGN, INC.225 ROCKY CREEK ROADGREENVILLE, SC 29615ARCHITECTCEDARWOOD ARCHITECTURE, INC.3200 WEST MARKET ST STE 200FAIRLAWN, OH 44333PROPOSED USEMULTI-FAMILY288 UNITSPARCEL ID5049-15-53-6094, 5049-15-53-4419DEVELOPMENT AREANATURAL HERITAGE AREAAMENITY AREA3.96 AC REQUIRED3.97 AC PROVIDEDPARCEL AREA19.8 ACRESSETBACKSFRONT: 20'SIDES: 7'REAR: 10' PROPOSEDHYDRANT (TYP.) PROPOSEDHYDRANT (TYP.) PROPOSEDHYDRANT (TYP.) R400.0' PROPOSEDHYDRANT (TYP.) 17.8' 114.3'119.8'107.8'48.6' 194.7' 106.4' 138.5' 114.3' N ADAMS CTTURNER HILL RDTURNERPOINTE RD KAY DR US HWY 123SITE 213.9' 113.0' 21.4' 242.0' 78.2'76.8'61.2'WETDETENTIONPOND BLDG #824 UNITS(3 STORY) CLUBHOUSE BLDG #128 UNITS(3/4 STORY SPLIT) BLDG #228 UNITS(3/4 STORY SPLIT) BLDG #724 UNITS(3 STORY) BLDG #328 UNITS(3/4 STORY SPLIT) BLDG #428 UNITS(3/4 STORYSPLIT) BLDG #528 UNITS(3/4 STORY SPLIT)BLDG #628 UNITS(3/4 STORY SPLIT) BLDG #1024 UNITS(3 STORY) BLDG #1124 UNITS(3 STORY) BLDG #924 UNITS(3 STORY) LAND USE: COMMERCIAL LAND USE: COMMERCIALLAND USE: SINGLEFAMILY RESIDENTIAL LAND USE: SINGLEFAMILY RESIDENTIAL LAND USE: COMMERCIALLAND USE: WAREHOUSE- LIGHT 20.8'67.4'195.0'55.5' 106.3' 114.3' 114.3'108.5'44.9'19.4'140.0'206.9'50.5'61.3' 52.8' 35.1'107.9' 79.4' 210.9' 107.0' 48.1'80.0' 100.4'35.2' Source: Esri, Maxar, GeoEye, Earthstar Geographics, CNES/Airbus DS, USDA, USGS, AeroGRID, IGN, and the GIS User Community Powered by Esri www.sitedesign-inc.com 225 ROCKY CREEK ROAD GREENVILLE, SC 29615 PH: (864)271-0496 CIVIL ENGINEERS - SURVEYORS - LANDSCAPE ARCHITECTS© Know what's below.Call before you dig. 20.0' 20' FIREACCESS LANE 20.0' 12.0' N ADAMS CTTURNER HILL RDTURNERPOINTE RD KAY DR US HWY 123SITE 100.0' STORAGE200.0' TAPER VEHICLE TURNING MOVEMENTSSCALE: 1" = 30' HEAVY DUTYASPHALT IN SCDOTRIGHT OF WAY LIGHT DUTYASPHALT ONPRIVATE ROADWAY50' RIPARIANBUFFER 11.0' 2.0'18.0' 4.0' 150.0' STORAGE200.0' LEFT TURN TAPER 2.0' 75.0' STORAGE200.0' LEFT TURN TAPER12.0'4.0'2.0' 16.0' 27.0'EXISTINGEOP CALHOUN MEMORIAL HWY (US HWY 123)(VARIABLE WIDTH SCDOT R.O.W.) CALHOUN MEMORIAL HWY (US HWY 123)(VARIABLE WIDTH SCDOT R.O.W.) 12.0'12.0' Ridge at Perry Bend Three | iii EXECUTIVE SUMMARY A traffic impact study was conducted for the proposed Ridge at Perry Bend Three development in accordance with SCDOT guidelines. The proposed development is located to the south of US 123, east of Turner Hill Road, in Pickens County, South Carolina. The development is expected to consist of up to 288 low-rise multi- family units and is anticipated to be constructed by the end of 2028. Access to the site is proposed to be provided via a full movement connection to US 123. A turn lane analysis was conducted utilizing the Build ( 2028) volumes. Based on build out volumes, a left turn lane is warranted on US 123 at Site Access. It is recommended that a left turn lane be constructed with 150-foot storage and appropriate taper at Site Access. The capacity analysis indicates that all approaches at the study intersection US 123 and Kay Drive / Turner Hill Road are expected to maintain their LOS from No -Build to Build Conditions. The eastbound and westbound approaches for the study intersection US 123 and Auto Shop Access / Site Access are expected to operate at a LOS C or better in all scenarios. The delay for the side street approaches is expected to be somewhat lower than reported due to the inability of the Synchro software to model a two-stop left turn using the wide median on US 123. It is also expected for a portion of traffic in the peak hours to make a right onto US 123 eastbound and later perform a U -turn. Although, it is not uncommon for stop-controlled side street approaches to experience high delays during peak hours when mainline through volumes are the highest. Therefore, no mitigation is recommended at these intersections based on the capacity analysis. Recommendations: • Construct a 150-foot left turn lane on US 123 at Site Access. To Whom it May Concern, Please accept this letter on behalf of the School District of Pickens County. The district has no objection to the proposed/discussed development of approximately 12 apartment buildings with 288 units that Cedarwood Development, Inc. is proposing to build at 4215 Calhoun Memorial Highway in Pickens County. Given the planned timeframe of construction and the zoned schools (Crosswell Elementary, Dacusville Middle, and Easley High) that would be affected should be able to handle any expected increase in students at this current time. Sincerely, Josh Young Associate Superintendent of Administration FIRE FLOW REQUEST ANALYSIS RESULTS PROJECT INFORMATION Name: Ridge at Perry Bend Location: 4215 Calhoun Memorial Hwy Easley, SC 29640 County Name: Pickens County Parcel #: 5049-15-53-6094 OWNER INFORMATION Name: Cedarwood Development, LLC Mr. Rick Dilsavor Address: 3200 W Market St Suite 200 Akron, OH 44333 Phone: Email: OWNER’S REPRESENTATIVE Name: Craig Winnall Site Design, Inc. Address: 225 Rocky Creek Rd Greenville, SC 29615 Phone: Email: FIRE FLOW ANALYSIS INFORMATION Date of Analysis: 7/18/2025 Performed By: Black and Veatch FIRE FLOW ANALYSIS RESULTS Hydrant # for Flow Test Static Pressure PSI Residual Pressure PSI Flow Rate GPM Estimated Fire Flow Available at 50 PSI (Max Day, Peak Hour) Hyd 280 125 115 1590 2150 Hyd 290 125 115 1635 2500 Location Elevation (feet) 2024 Peak Hour Modeled Pressure (psi) 2030 Peak Hour Modeled Pressure (psi) Est. Fire Flow (fpm) at 50 psi Residual (2024 system maximum day/peak hour) Est. Fire Flow (fpm) at 50 psi Residual (2030 system maximum day/peak hour) Highest Ground Elevation 884 110 108 2200 2150 Lowest Ground Elevation 828 134 132 2600 2500 CERTIFICATION INFORMATION Name: Chris Rasco Signature: Date: 7/23/2025 LU-25-0007: Ridge at Perry Three Staff Report Planning Commission Public Hearing: December 08, 2025, 6:30 PM The following report constitutes an assessment and evaluation by Planning Staff on the above mentioned request. Applicant: Rick Dilsavor 3200 W Market St., Suite 200 Fairlawn, OH 44333 Property Owner(s): Avery Outparcel Associates, LLC Property Location: 4215 & 4225 Calhoun Memorial Hwy Easley, SC 29640 Acreage: 19.8 acres Tax Map Number: 5049-15-53-6094 & 5049-15-53-4419 County Council District: 6 Land Use Request: Requesting to develop a multi-family residential complex comprised of 11 buildings. Variance Request(s) from Planning Commission: None Request Overview: The proposed apartment development includes 11 buildings, with a total of 288 units , spread across 19.8 acres. Of this total area, 3.97 acres will be designated as amenity areas. The proposed development is situated within the Natural Heritage Area . Access to the development will be provided via Calhoun Memorial Hwy, which is maintained by the state. Current Property Use: The properties are listed on the Assessor’s site as commercial. Surrounding Area: The subject property is mostly surrounded by residential and commercial. Utilities & Infrastructure Transportation: The property is served by Calhoun Memorial Hwy (State Road) Water: Powdersville Water Sewerage: Easley Combined Utilities Comments from Reviewing Agencies: SCDOT: A minimum taper of 200 feet and 75 feet of storage is recommended, along with at least 150 feet of storage dedicated for an eastbound left turn lane. Additionally, a raised median serving as the outermost eastbound lane is not recommended. Pickens County Emergency/Fire Services: Cedarwood Development agrees to provide up to $75,000 toward the purchase of a ladder truck for the Pickens County Fire Service as the need for the truck arises. Pickens County School District: No objection, the zoned schools (Crosswell Elementary, Dacusville Middle, and Easley High) would be able to handle any expected increase in students at this current time. Staff Analysis of Standards for Land Use Approval: Staff analysis of the application is made based upon the findings criteria as set forth in Section 314 of the UDSO. The applicant has submitted his/her response to the same findings criteria. A. Is the proposed use consistent with other uses in the area or the general development patterns occurring in the area? The proposed use is consistent with uses in the immediate area or the general development patterns in the area. B. Will the proposed use adversely affect the existing use or usability of adjacent or nearby property? With strict adherence to the development standards for the proposed uses, the proposed use should not adversely affect the existing use of adjacent property. C. Is the proposed use compatible with the goals, objectives, purpose , and intent of the Comprehensive Plan? The proposed use is not consistent with the Comprehensive Plan as it designates the area for Residential Growth. D. Will the proposed use not cause an excessive or burdensome use of public facilities or services, including but not limited to streets, schools, water or sewer utilities, and police or fire protection? If developed according to the County development standards, the project should not burden existing facilities or services. E. Is the property suitable for the proposed use relative to the requirements set forth in this development ordinance such as off -street parking, setbacks, buffers, and access? The applicant’s proposal before the Commission will meet the respective standards as outlined in the Unified Development Standards Ordinance of Pickens County. F. Does the proposed use reflect a reasonable balance between the promotion of the public health, safety, morality, or general welfare and the right to unrestricted use of property? The proposed development should provide for a balance of competing interests. Requirements for Multi-Family Residential Developments: 314 Multi-Family Residential Developments (including townhomes) The following design standards shall govern the development of attached, multi-family or townhome residential dwellings consisting of three (3) or more units on a single parcel of land. Such developments may be defined as a triplex development, an apartment development, condominium development, or townhouse development, depending on ownership arrangements. (Section Amended 4/1/2024, Amended 11/4/2024) 314 (a) Requirements in general. (1) Recreation amenities. Every multi-family development located on property that is singularly controlled and owned must contain a community recreation amenity of adequate size and variety to serve the development. Examples include a community pool, tennis courts, tot lot/playground, basketball courts, bike/walking trails, etc. (2) Off-Street parking shall be governed by Article VI (3) Buffers requirements shall be governed by Article VIII (4) Height restrictions shall be governed by Section IV 314 (c) Apartment/Condominium Developments (1) Density a. Density of an apartment or condominium development shall not exceed four (4) units per acre when served by a community on-site septic system and shall not exceed eight (8) units per acre when served by a public sewer system in the Appalachian, Agricultural, and Natural Heritage areas. Units may not be served by individual on-site systems. Parcels with access to public water and public sewer in the Community Center area shall mirror density standards of the adjacent municipality. Parcels with access to public sewer in the Gateway area shall be allowed a density of forty (40) units or one hundred twenty (120) bedrooms per acre and shall be allowed a height of five (5) stories. 1. Exception a) When a property and development is served by and has direct access and frontage onto a four (4) lane, divided, minor arterial as defined in Section 1010(b) of this development ordinance, project density shall not exceed sixteen (16) units per acre. b) The development must be served by public water and public sewer. c) Design standards 1) All buildings or structures shall utilize a common architectural theme that is consistent throughout the development 2) All buildings or structures should be sided entirely of brick, stucco, or stone finish, or painted wood or fiber cement lap siding (such as Hardiplank). 3) No less than twenty percent (20%) of the gross site must be devoted and set aside for the recreation amenities listed in 314(a)(1). b. No more than four (4) dwelling units per floor may be included within a singular building or structure. 1. Exception a) No more than eight (8) dwelling units per floor may be included within a singular building or structure when the above exception (Sec.314(c)(1)(a)1.) is used. b) Access to apartment or condominium projects shall be governed by the standards enumerated in Section 309(c) for similar Large Scale Projects. Planning Staff Recommendation: The proposed site plan will comply with the standards set forth in the Unified Development Standards Ordinance. 61 CHAPTER 5 | LAND USE DRAFT | APRIL 2022 Character Areas Recreation and Open Space Community Commercial Center Agricultural Preservation Commercial Gateway CorridorRural Places Workplace Centers Residential Growth Institutional and Educational Urban Residential SR 11 Scenic Corridor Neighborhood Commercial Center Pickens County, SC Developed by Parcel ID    5049-15-53-4419 Account No   R0081976 Property Address    4225 CALHOUN MEM HWY A EASLEY District G10-Georges Creek/Crosswell Brief Tax Description  S/SIDE HWY 123 PLAT 596/257 PLAT 313/8 (Note: Not to be used on legal documents) Account Type   Commercial Class   Neighborhood Strip Shopping Center Acreage   0.55 LEA Code   0105 Value   $472,600 Ownership   WAYNESVILLE ENTERPRISES LLC 3200 W MARKET ST STE 200 FAIRLAWN, OH 44333-0000 Documents Date   Price   Doc   Vacant or Improved   11/2/2022   $450,000   2469/ / 239   Improved   12/6/2011   $135,000   1424 / 172   Improved   Date created: 7/8/2025 Last Data Uploaded: 7/8/2025 9:08:05 AM 295 ft Overview Legend Parcels Parcel Numbers 911 Address Municipalities Roads

Source: Pickens County website. First collected Oct 23, 2026.