Board of Architectural Review
REVISED AGENDA
City Hall in Council Chambers
Wednesday, October 21, 2026
5:30 pm
I. Addenda to Agenda
II. Approval of Minutes – from September 16, 2026
III. New Business
• BAR-26-37 203 Henry Ave (shed)
• BAR-26-47 120 E Earle (windows)
• BAR-26-50 109 E Calhoun (sign)
• BAR-26-46 905 E Greenville (color)
• BBA-26-5 905 E Greenville (Preliminary Certification Special Property Tax Assessment
for Rehabilitated Properties)
IV. Addenda
• BAR-26-54 119 W Benson (sign)
• BAR-26-33 240 E Whitner (revisions to BAR approval)
V. Board Business
VI. Staff Report
VII. Adjourn
1
CITY OF ANDERSON
BOARD OF ARCHITECTURAL REVIEW
MINUTES
Wednesday, September 16, 2026
5:30 pm
MEMBERS PRESENT: Bill Johnson, Michael Cousar, Mary Lou Gambrell, Jill Helgeson
MEMBERS ABSENT: Amanda Knobel, Gia Townsley, Billy Zion
STAFF PRESENT: Christopher Darnel, City Planner
OTHERS PRESENT: See sign-in roster.
CALL TO ORDER
The meeting was called to order by Bill Johnson.
ADDENDA TO AGENDA
None
APPROVAL OF MINUTES
A motion by Michael Cousar, a second by Jill Helgeson (4-0), to approve the minutes from October
23, 2026.
BAR-26-40
609 N McDuffie St (multi-tenant building sign)
This application is for a new multi-tenant monument sign to replace an existing nonconforming
pylon sign.
When reviewing this application, the Board should use the standards set forth in Chapter Eight
of the Design Guidelines for Downtown Anderson – Design Guidelines for Signs. The following
sections apply to this request:
Policy: Design a sign to be in balance with the overall character of the property.
8.1 - Consider the building front as part of an overall sign program.
• Coordinate a sign within the overall facade composition.
2
Policy: Appropriate signs include freestanding, flush mounted, window, projecting,
hanging, and directory signs.
8.3 - Freestanding or pole mounted signs may be considered.
• A freestanding sign may also be used in areas where the primary use is set back from
the street edge.
Policy: A sign should be in character with the material, color and detail of a building.
8.13 - Sign materials should be compatible with that of the building facade.
8.15 - Use colors for the sign that are compatible with those of the building front.
The Comprehensive Sign Plan section of the Sign Ordinance gives the Board of Architectural
Review an alternative procedure under which signs can be approved to encourage a higher
level of design and amenity that would not be possible under applicable sign regulations.
Monument signs are not allowed in the CBD per the sign ordinance but are a potential option
listed in the Design Guidelines for Downtown Anderson. Given that the building setbacks back
from the street, a wall sign would not serve to identify the business. The exisitng monument sign
cannot be altered because it is nonconforming and will be removed as part of this approval. The
BAR has the authority, and Staff recommends approval of this sign application as submitted.
A motion was made by Michael Cousar, with a second from Mary Lou Gambrell, and carried (4-
0) to approve as submitted with the condition that the existing pylon sign is removed.
BAR-26-43
315 N Main St (Kira Noodle House sign)
This application is for a new wall sign above the main door on the Main St. facade.
When reviewing this application, the Board should focus on the standards set forth in Chapter
Eight of the Design Guidelines for Downtown Anderson – Design Guidelines for Signs. The
following sections apply to this request:
Policy: Design a sign to be in balance with the overall character of the property.
8.1 - Consider the building front as part of an overall sign program.
• Coordinate a sign within the overall facade composition.
Policy: Appropriate signs include freestanding, flush mounted, window, projecting,
hanging, and directory signs.
8.4 - A flush-mounted wall sign may be considered.
Policy: A sign should be in character with the material, color and detail of a building.
8.13 - Sign materials should be compatible with that of the building facade.
8.15 - Use colors for the sign that are compatible with those of the building front.
8.16 - A simple sign design is preferred.
• Typefaces that are in keeping with those seen in the area traditionally are encouraged.
Select letter styles and sizes that will be compatible with the building front.
3
• Generally, these are typefaces with serifs.
• Avoid hard-to-read or overly intricate typeface styles.
The sign complies with the standards of the sign ordinance and Design Guidelines for
Downtown. The sign ordinance was written to eliminate use of two-dimensional, low-quality
cabinet signs in favor of individual channel letters. The letters and logo have 1” of relief on the
sign face and the window signs comply with size and material standards. Staff recommends
approval as submitted with the condition that the awning fabric is replaced in black (with no
sign).
A motion was made by Mary Lou Gambrell with a second from Jill Helgeson and carried (4-0) to
approve as submitted.
BAR-26-44
220 E Morris St (Caldwell-Johnson-Morris Cottage exterior restoration)
The applicant request approval to restore the front portico, steps and foundation lattice to their
original condition, repaint the exterior of the house, and add a picket fence.
The proposed colors are recommendations of a report on this building prepared by the Palmetto
Trust of Historic Preservation and represent indications of the original colors on the building and
what was historically available at that time. Quoting from this report, “Contrary to the hard-shell
stereotype still held, not all ‘Greek Revival’ structures were painted show white with black or
blackish-green shutters.” The colors discovered on the building were matched to samples from
Benjamin Moore’s Historic Collection.
• House body – Benjamin Moore “Powell Buff” (HC-35)
• Trim & Balustrade – Benjamin Moore “Lancaster Whitewash” (HC-174)
• Shutters - Benjamin Moore “Park Green” (HC-40)
• Stair Treads & Portico Decking - Benjamin Moore “Rich Brown (HC-60)
• Lattice & Handrails - Benjamin Moore “Crome Green”
• Portico Ceiling - Benjamin Moore “Castleton Mist (HC-1)
• Brick Piers (faux quarried stone technique) – Sherwin-Williams BM-72-22 stone
• Brick Infill (behind lattice) - Sherwin-Williams BM-72-22
• Front door – painted to resemble mahogany
• Fence - Benjamin Moore “Park Green” (HC-40)
When reviewing this application, the Board should focus on Chapter 3: Rehabilitation of Historic
Resources of the Design Guidelines. The following sections apply to this request:
3.17 Using the historic color scheme is encouraged.
• If an historic scheme is not to be used, then consider the following:
- Generally, one muted color is used as a background to unify the composition.
- One or two colors are usually used for accent to highlight details and trim.
4
- A single-color scheme should be used for the entire exterior so upper and lower
floors and subordinate wings of buildings are seen as components of a single
structure.
3.18 Base or background colors should be muted.
• Use the natural colors of the building materials, such as the buff color of limestone, as
the base for developing the overall color scheme.
• Use matte finishes instead of glossy ones.
Policy: A fence or site wall should be in character with those used traditionally and relate to the
principal structure on a lot.
5.8 Appropriate materials for fences that can be seen from the public right-of-way are wrought
iron or wood picket.
5.9 A side yard fence should be set back from the primary facade of a house.
Staff recommends approval. The proposed restoration complies with the Design Guide.
A motion was made by Jill Helgeson, with a second from Mary Lou Gambrell, and carried (4-0)
to approve as submitted.
BBA-26-4
220 E Morris St (Preliminary Certification Special Property Tax Assessment for
Rehabilitated Properties)
A motion was made by Jill Helgeson, with a second from Michael Cousar, and carried (4-0) to
approve.
BAR-26-45
113 N Main St (Miss Lillies Childrens Boutique sign)
This application is for a new wall and projecting sign. Both comply with Chapter 6: Signs
Standards (adopted 8/24/2026) of the Unified Development Ordinance and Design Guide for
Downtown.
When reviewing this application, the Board should focus on the standards set forth in Chapter
Eight of the Design Guidelines for Downtown Anderson – Design Guidelines for Signs. The
following sections apply to this request:
Policy: Design a sign to be in balance with the overall character of the property.
8.1 - Consider the building front as part of an overall sign program.
8.2 - A sign shall be subordinate to the overall building composition.
Policy: Appropriate signs include freestanding, flushmounted, window, projecting,
hanging, and directory signs.
8.7 – A projecting sign may be considered
5
Policy: A sign should be in character with the material, color and detail of a building.
8.13 - Sign materials should be compatible with that of the building facade.
8.15 - Use colors for the sign that are compatible with those of the building front.
8.17 - The light for a sign should be an indirect source.
Staff recommends approval as submitted.
A motion was made by Jill Helgeson, with a second from Mary Lou Gambrell, and carried (4-0)
to approve as submitted.
BBA-26-3
113 N Main St (Preliminary Certification Special Property Tax Assessment for
Rehabilitated Properties)
A motion was made by Michael Cousar, with a second from Jill Helgeson, and carried (4-0) to
approve.
Board Business
None
ADJOURNMENT
A motion by Michael Cousar, a second by Mary Lou Gambrell (4-0), to adjourn.
_____________________________ ____________________________
Bill Johnson Shalandrea Geer
Chairman Secretary
STAFF REPORT
CITY OF ANDERSON BOARD OF ARCHITECTURAL REVIEW
Application Number: BAR-26-37
Applicant: Jason Eaton
Property Address: 203 Henry Ave. (North Anderson Historic District)
Zoning of Property: NR, Neighborhood Residential
ANALYSIS
The applicant is seeking approval of a 16’ x 12’ shed. The location and scale of the shed can be
viewed because construction has already started. It sets back over 90’ from the curb. The BZA
granted a variance to locate the shed forward of the front elevation of the house.
Materials on the shed include:
1. Windows - vinyl SDL divided to match the house,
2. Siding - horizontal lap siding with 7” reveal cement board or wood to match the house,
3. Soffits – vinyl,
4. Roof – asphalt shingles to match the house,
5. Fascia – aluminum,
6. Color
a. Body – grey to match the house,
b. Trim (soffits & fascia) – white to match the house.
When reviewing this application, the Board should focus on the standards set forth in Chapters 3
and 6 of the Design Guidelines, Historic Districts in Anderson, South Carolina. The following apply
to this request:
3.17 Using the historic color scheme is encouraged.
Policy: An accessory structure should not overwhelm or visually compete with the primary
structure.
6.32 An accessory structure should be located in the rear yard of the primary residence.
6.34 An accessory structure should be simple in form and character.
Staff recommends approval. The storage building is consistent with what would have historically
been constructed and coordinates with the colors of the primary building. The perceived character
of the building or neighborhood is not adversely affected because the shed is set so far back from
the road.
STAFF REPORT
CITY OF ANDERSON BOARD OF ARCHITECTURAL REVIEW
Application Number: BAR-26-47
Applicant: Michael Gardner
Property Address: 120 E. Earle St (Downtown Historic District)
Zoning of Property: CBD, Central Business District
ANALYSIS
The applicant request approval to re-open original windows that had been bricked up on the west
side of the building. The windows installed will match the windows on the building approved by the
BAR in 2022.
When reviewing this application, the Board should focus on the standards set forth in Design
Guidelines, Historic Districts in Anderson – Chapter 1 and 2. The following sections apply to this
request:
Chapter 1 - Design of Alterations
1. Avoid alterations that would damage historic features or materials.
Chapter 2 - Design of New Additions
4.7 Use building materials that are compatible with those of the primary structure.
4.8 Use windows that are similar in character to those of the main structure.
Given the proposed windows will match the exisitng, the proposed changes are consistent with the
existing materials and finishes currently on the building. The proposed changes will return the
building to a state closer to original construction and not adversely affect the perceived character of
the building or neighborhood. Staff recommends approval as submitted.
120 East Earle St
2022 New/Existing
Windows Front and
Back Walls of
Building.
Black Aluminum
Casement (Operable)
– Supplier: Crystal
Windows and Doors
3 Existing Windows
Black Aluminum Picture (Fixed).
Exterior Wall
BAR Candidate
Previous Window
Openings, Bricked Over
Existing 3 Windows, Black
Aluminum Picture (Fixed).
- Will add Mullions (2 over 2 grid to match 2022
front back wall windows)
Re-Open 5 Windows, Black Aluminum
Casement (Operable)
- 2 over 2 grid configuration
- Same Windows as Front / Back of Building (2022 upfits)
New Window Spec Sheet
Same as 2022 front and
back wall windows, Black
2 over 2 existing
window grid front and
back building walls
2 over 2
existing
window grid
front and
back building
walls
2 over 2 tape configuration
STAFF REPORT
CITY OF ANDERSON BOARD OF ARCHITECTURAL REVIEW
Application Number: BAR-26-50
Applicant: Marisa Swaney
Property Address: 109 E Calhoun St
Zoning of Property: CBD / Central Business District
ANALYSIS
This application is for approval of changes already made to a painted wall sign. The name of the
business is the only thing on the existing painted wall sign that was changed. The colors and font
remain the same.
When reviewing this application, the Board should focus on the standards set forth in Chapter Eight
of the Design Guidelines for Downtown Anderson – Design Guidelines for Signs. The following
sections apply to this request:
Policy: Design a sign to be in balance with the overall character of the property.
8.1 - Consider the building front as part of an overall sign program.
• Coordinate a sign within the overall facade composition.
Policy: Appropriate signs include freestanding, flush mounted, window, projecting,
hanging, and directory signs.
8.4 - A flush-mounted wall sign may be considered.
Policy: A sign should be in character with the material, color and detail of a building.
8.13 - Sign materials should be compatible with that of the building facade.
8.15 - Use colors for the sign that are compatible with those of the building front.
8.16 - A simple sign design is preferred.
• Typefaces that are in keeping with those seen in the area traditionally are encouraged.
Select letter styles and sizes that will be compatible with the building front.
• Generally, these are typefaces with serifs.
• Avoid hard-to-read or overly intricate typeface styles.
The sign complies with the standards of the UDO and Design Guidelines for Downtown. Staff
recommends approval as submitted.
STAFF REPORT
CITY OF ANDERSON BOARD OF ARCHITECTURAL REVIEW
Application Number: BAR-26-46
Applicant: Jacob Babineau
Property Address: 905 E Greenville St (Boulevard District)
Zoning of Property: SR, Suburban Residential
ANALYSIS
The applicant request approval to paint the exterior of the house. Photos of the house show it was
originally painted white when it was built. The applicant would like the flexibility to paint the body
and trim of the house one of the following whites:
1. Sherwin Williams Parish white - SW-15
2. Sherwin Williams Prentis Cream - SW-100
3. Sherwin Williams Lancaster Whitewash - HC-174
4. Sherwin Williams
Antique White SW-6119
5. Benjamin Moore Soft Chamois - OC-13
The existing windows will remain and be painted white. Shingles and gutters will be repaired to
match existing.
When reviewing this application, the Board should focus on Chapter 3: Rehabilitation of Historic
Resources of the Design Guidelines. The following sections apply to this request:
3.17 Using the historic color scheme is encouraged.
• If an historic scheme is not to be used, then consider the following:
- Generally, one muted color is used as a background to unify the composition.
- One or two colors are usually used for accent to highlight details and trim.
- A single-color scheme should be used for the entire exterior so upper and lower
floors and subordinate wings of buildings are seen as components of a single
structure.
3.18 Base or background colors should be muted.
• Use the natural colors of the building materials, such as the buff color of limestone, as the
base for developing the overall color scheme.
• Use matte finishes instead of glossy ones.
Staff recommends approval. The color scheme complies with the Design Guide and appears to be
historically accurate.
905 E GVL St. – Proposed Floorplan Enhancements for Property Restoration
Main Level
• Convert Jack/Jill Bedroom into Master Suite
o Existing bathroom enlarged converted into closet space
o Existing closets removed and used as walking space
o Front bedroom converted into master bathroom
o Entryway from formal living room closed off
• Kitchen to Living Room Transition
o Opening enlarged
o Adding cabinetry and island
• Current Mechanical Room converted into Full Bathroom
o Mechanical Room being shifted into current “mud room”
• Den – Conversion into large bedroom/flex space
o ***The existing closets are not shown in the existing floorplan.
Upper Level
• Expand shower space in north bathroom.
• Expand south bathroom into existing closet.
o Add door to make this a jack/jill bathroom serving both south bedrooms
• Closet removed
o Converting dead hallway space into two closets for each bedroom
Crawl Space (not shown on floor plan)
• Installing exterior door for better access as current access point is almost inaccessible and will be covered
up by adding full bathroom to main level (as noted above).
Estimated Renovation Costs - $360,000-$380,000
STAFF REPORT
CITY OF ANDERSON BOARD OF ARCHITECTURAL REVIEW
Application Number: BAR-26-54
Applicant: Cierra Coon
Property Address: 119 W Benson St
Zoning of Property: CBD, Central Business District
ANALYSIS
This application is requesting approval to replace the storefront door, a projecting sign, and window
sign. The colors are as follows:
1. The doorframe will be painted to match the exisitng building trim.
2. Window sign will be white vinyl letters.
3. Projecting sign bracket / frame will be the Cerchio Bracket in black.
4. Projecting sign background is dark wood grain.
5. Projecting sign text will be white.
The proposed complies with Chapter 6: Signs Standards (adopted 8/24/2026) of the Unified
Development Ordinance and Design Guide for Downtown.
When reviewing this application, the Board should focus on the standards set forth in Chapter Eight
of the Design Guidelines for Downtown Anderson – Design Guidelines for Signs. The following
sections apply to this request:
Policy: Design a sign to be in balance with the overall character of the property.
8.1 - Consider the building front as part of an overall sign program.
8.2 - A sign shall be subordinate to the overall building composition.
Policy: Appropriate signs include freestanding, flushmounted, window, projecting, hanging,
and directory signs.
8.7 – A projecting sign may be considered
Policy: A sign should be in character with the material, color and detail of a building.
8.13 - Sign materials should be compatible with that of the building facade.
8.15 - Use colors for the sign that are compatible with those of the building front.
8.17 - The light for a sign should be an indirect source.
Staff recommends approval as submitted.
CERCHIO BRACKET 419B-18 -18" STEEL Black Powder Coat Charlie RM 07/20251. Includes Sign BlankAB100-C-C18-100
FRONT VIEW14"8"8-7/8"3/16"14"3"1/2"1/2"SIDE VIEW PERSPECTIVE VIEW
1" Square Tubing(4) 3/8" Thru Holes(4) 1/4" Thru Holes, EquallySpaced For Moutning Sign Blank18" Sign BlankIncluded
)7
IWIURPVLGHZDON
)7
´
´
*ODVV´
*ODVV´
/RJRWREH´[´
STAFF REPORT
CITY OF ANDERSON BOARD OF ARCHITECTURAL REVIEW
Application Number: BAR-26-33
Applicant: Billy Zion
Property Address: 240 W Whitner (Downtown Historic District)
Zoning of Property: GC, General Commercial
ANALYSIS
The applicant is requesting approval of the following exterior renovations:
1. New brick veneer on storefront (General Shale – Valhalla Mist),
2. Addition of brick columns with privacy perimeter fence and gate,
3. Addition of deck with tension wire railing and covered carport below,
4. Addition of awnings with black standing seam metal roof over clerestory windows and new
second level door,
5. Monogram Sign
6. Paint colors:
a. Main façade color (painted brick) - Sherwin Williams, Online SW 7072
b. Accent color (storefront, fence, carport) – Sherwin Williams, Web Grey SW 7075
When the element to be replaced is not original to the building, the basic principle to consider is to
not alter the perceived character of the building. When reviewing this application, the Board should
focus on the “Basic Principles of Historic Preservation” set forth in the Design Guidelines, Historic
Districts in Anderson, South Carolina that include:
• Respect the historic design character of the building.
• Protect and maintain significant features and stylistic elements.
• Preserve key, character-defining features of the property.
• Use building materials that appear similar to those used traditionally in Anderson.
When reviewing this application, the Board should focus on Chapter 3: Rehabilitation of Historic
Resources, Chapter 4: Additions of the Design Guidelines, and Chapter 8: Design Guidelines for
Signs.
The following sections apply to this request:
3.17 Using the historic color scheme is encouraged.
• If an historic scheme is not to be used, then consider the following:
- Generally, one muted color is used as a background to unify the composition.
- One or two colors are usually used for accent to highlight details and trim.
- A single-color scheme should be used for the entire exterior so upper and lower floors and
subordinate wings of buildings are seen as components of a single structure.
3.18 Base or background colors should be muted.
• Use the natural colors of the building materials, such as the buff color of limestone, as the
base for developing the overall color scheme.
• Use matte finishes instead of glossy ones.
3.19 Reserve the use of bright colors to accent building features only.
• Contrasting accent colors may be used to highlight entries.
• Muted earthtone colors are preferred.
4.3 Place an addition at the rear of a building or set it back from the front to minimize the
visual impacts.
• This will allow the original proportions and character to remain prominent.
4.5 An addition should be compatible in scale with the primary structure.
• An addition should relate to the historic resource in mass, scale and form. It should be
designed to remain subordinate to the main structure.
4.6 An addition should be compatible in character with the primary structure.
Policy: Design a sign to be in balance with the overall character of the property.
8.1 Consider the building front as part of an overall sign program.
8.2 A sign shall be subordinate to the overall building composition.
Policy: Appropriate signs include freestanding, flushmounted, window, projecting, hanging,
and directory signs.
8.7 A projecting sign may be considered
Policy: A sign should be in character with the material, color and detail of a building.
8.13 Sign materials should be compatible with that of the building facade.
8.15 Use colors for the sign that are compatible with those of the building front.
8.17 The light for a sign should be an indirect source.
The proposed architectural detail, material, finishes, and color comply with the Design Guide. The
proposed materials are consistent with the existing materials and finishes currently on the building.
The proposed changes will not adversely affect the perceived character of the building or
neighborhood. Staff recommends approval as submitted.
E WHITNER STREETS MANNING STREETEXISTING BUILDING
NEIGHBORINGBUILDING(NOT IN SCOPE)EXISTING CMURETAINING WALL
GATEDECK WITH CARPORT BELOW(DESIGN TO MATCHDANIEL BUILDERS)
PAVED AREAGREEN SPACE
BRICK COLUMN FENCEWITH BRICK PLANTERSFLAG POLE LOCATION
A100
HOCKMAN RESIDENCE240 E. Whitner Street - Anderson, SCRESIDENTIAL UPFIT08 JULY 2026
SCALE:PROPOSED SITE PLAN1A1001/16" = 1'-0"
A101
HOCKMAN RESIDENCE240 E. Whitner Street - Anderson, SCRESIDENTIAL UPFIT08 JULY 2026
SCALE:PROPOSED RENDERING - EXTERIOR VIEW 11A101NTS
SW 7072ONLINESW 7075WEB GRAYMATERIAL NOTES:-DECK/RAILING DESIGN: TO MATCH DANIEL BUILDERS-AWNINGS: METAL BRACKETS WITH BLACK STANDING SEAM METAL ROOF-WINDOWS: BLACK FRAME-MAIN FACADE COLOR: SW 7072 - ONLINE-ACCENT COLOR: SW 7075 - WEB GRAY-ACCENT BRICK: GENERAL SHALE - VALHALLA MISTGENERAL SHALEVALHALLA MIST
A102
HOCKMAN RESIDENCE240 E. Whitner Street - Anderson, SCRESIDENTIAL UPFIT08 JULY 2026
SCALE:PROPOSED RENDERING - EXTERIOR VIEW 21A102NTS
SW 7072ONLINESW 7075WEB GRAYMATERIAL NOTES:-DECK/RAILING DESIGN: TO MATCH DANIEL BUILDERS-AWNINGS: METAL BRACKETS WITH BLACK STANDING SEAM METAL ROOF-WINDOWS: BLACK FRAME-MAIN FACADE COLOR: SW 7072 - ONLINE-ACCENT COLOR: SW 7075 - WEB GRAY-ACCENT BRICK: GENERAL SHALE - VALHALLA MISTGENERAL SHALEVALHALLA MIST
A103
HOCKMAN RESIDENCE240 E. Whitner Street - Anderson, SCRESIDENTIAL UPFIT08 JULY 2026
SCALE:PROPOSED RENDERING - EXTERIOR VIEW 31A103NTS
SW 7072ONLINESW 7075WEB GRAYMATERIAL NOTES:-DECK/RAILING DESIGN: TO MATCH DANIEL BUILDERS-AWNINGS: METAL BRACKETS WITH BLACK STANDING SEAM METAL ROOF-WINDOWS: BLACK FRAME-MAIN FACADE COLOR: SW 7072 - ONLINE-ACCENT COLOR: SW 7075 - WEB GRAY-ACCENT BRICK: GENERAL SHALE - VALHALLA MISTGENERAL SHALEVALHALLA MIST
ARCHITECT:WILLIAM A. ZION, III, AIACONTACT: 864-477-9064BILLY.ZION@ZIONARCHITECTS.COM
HOCKMAN RESIDENCE |240 E. WHITNER ST | ANDERSON, SCRESIDENTIAL RENOVATION
REVISIONS:10/19 BAR2
COVERSHEET
SCALE: NTS
05/18/2026HOCKMAN RESIDENCE240 E. WHITNER ST | ANDERSON, SCRESIDENTIAL RENOVATION
A001
E WHITNER STREETS MANNING STREETEXISTING BUILDING
NEIGHBORINGBUILDING(NOT IN SCOPE)EXISTING CMURETAINING WALL
GATEDECK WITH CARPORT BELOW
PAVED AREAGREEN SPACE
BRICK COLUMN FENCEWITH BRICK PLANTERSFLAG POLE LOCATION48'24'
ARCHITECT:WILLIAM A. ZION, III, AIACONTACT: 864-477-9064BILLY.ZION@ZIONARCHITECTS.COMREVISIONS:10/19 BAR2
SITE PLAN
SCALE: NTS
05/18/2026HOCKMAN RESIDENCE240 E. WHITNER ST | ANDERSON, SCRESIDENTIAL RENOVATION
A002SCALE:PROPOSED SITE PLAN1A0021/8"= 1'-0"
ARCHITECT:WILLIAM A. ZION, III, AIACONTACT: 864-477-9064BILLY.ZION@ZIONARCHITECTS.COMREVISIONS:10/19 BAR2
SITE PLAN
SCALE: NTS
05/18/2026HOCKMAN RESIDENCE240 E. WHITNER ST | ANDERSON, SCRESIDENTIAL RENOVATION
A003SCALE:PROPOSED SITE PLAN1A003NTS
ARCHITECT:WILLIAM A. ZION, III, AIACONTACT: 864-477-9064BILLY.ZION@ZIONARCHITECTS.COMREVISIONS:10/19 BAR2
EXTERIORPERSPECTIVE
SCALE: NTS
05/18/2026HOCKMAN RESIDENCE240 E. WHITNER ST | ANDERSON, SCRESIDENTIAL RENOVATION
A004SCALE:EXTERIOR PERSPECTIVE1A004NTS
ARCHITECT:WILLIAM A. ZION, III, AIACONTACT: 864-477-9064BILLY.ZION@ZIONARCHITECTS.COMREVISIONS:10/19 BAR2
EXTERIORPERSPECTIVE
SCALE: NTS
05/18/2026HOCKMAN RESIDENCE240 E. WHITNER ST | ANDERSON, SCRESIDENTIAL RENOVATION
A005SCALE:EXTERIOR PERSPECTIVE1A005NTS
ARCHITECT:WILLIAM A. ZION, III, AIACONTACT: 864-477-9064BILLY.ZION@ZIONARCHITECTS.COMREVISIONS:10/19 BAR2
AWNINGDIMENSIONS
SCALE: NTS
05/18/2026HOCKMAN RESIDENCE240 E. WHITNER ST | ANDERSON, SCRESIDENTIAL RENOVATION
A006SCALE:AWNING DIMENSIONS1A006NTS
Source: City of Anderson website. First collected Oct 24, 2026.