Planning and Zoning Committee Agenda Documents 4.14.26
City of Memphis · Shelby County · meeting of Apr 14, 2026 · Agendas
Open the original document More from City of Memphis
This document is no longer listed on City of Memphis's website. We kept the copy we read.
Text
Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.
CITY OF MEMPHIS
COUNCIL AGENDA CHECK OFF SHEET
___________________________________________________________________________________
| ONE ORIGINAL | Planning & Development
| ONLY STAPLED | DIVISION
|TO DOCUMENTS| Planning & Zoning COMMITTEE: 3/ 24/2026
DATE
PUBLIC SESSION: 4 /14/2026
DATE
ITEM (CHECK ONE)
ORDINANCE X RESOLUTION REQUEST FOR PUBLIC HEARING
= = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = =
ITEM DESCRIPTION: Resolution pursuant to Chapter 9.6 of the Memphis and Shelby County Unified Development Code approving
a planned development at the subject property located at 0 Ikea Way known as case number PD 2026-001
CASE NUMBER: PD 2026-001
DEVELOPMENT: Galleria of Memphis Planned Development
LOCATION: 0 Ikea Way
COUNCIL DISTRICTS: District 1 and Super District 9 – Positions 1, 2, and 3
OWNER/APPLICANT: Brad Smith
REPRESENTATIVE: Mike Davis, The Reaves Firm
REQUEST: Amendment to PD 2013-313 to allow a hotel
AREA: +/-2.39 acres
RECOMMENDATION: The Division of Planning and Development recommended Approval with outline plan conditions
The Land Use Control Board recommended Approval with outline plan conditions
RECOMMENDED COUNCIL ACTION: Public Hearing Not Required
Hearing – April 14, 2025
= = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = =
PRIOR ACTION ON ITEM:
(1) APPROVAL - (1) APPROVED (2) DENIED
03/12/2026 DATE
(1) Land Use Control Board ORGANIZATION - (1) BOARD / COMMISSION
(2) GOV’T. ENTITY (3) COUNCIL COMMITTEE
= = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = =
FUNDING:
(2) REQUIRES CITY EXPENDITURE - (1) YES (2) NO
$ AMOUNT OF EXPENDITURE
$ REVENUE TO BE RECEIVED
SOURCE AND AMOUNT OF FUNDS
$ OPERATING BUDGET
$ CIP PROJECT #_______________________________
$ FEDERAL/STATE/OTHER
= = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = =
ADMINISTRATIVE APPROVAL: DATE POSITION
_____________________________________________ ____________ PLANNER II
_____________________________________________ ____________ DEPUTY ADMINISTRATOR
_____________________________________________ ____________ ADMINISTRATOR
_____________________________________________ ____________ DIRECTOR (JOINT APPROVAL)
_____________________________________________ ____________ COMPTROLLER
_____________________________________________ ____________ FINANCE DIRECTOR
_____________________________________________ ____________ CITY ATTORNEY
= = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = =
_____________________________________________ ____________ CHIEF ADMINISTRATIVE OFFICER
_____________________________________________ ____________ COMMITTEE CHAIRMAN
3/16/2026
3/16/2026
3/16/2026
Memphis City Council
Summary Sheet
PD 2026-001
RESOLUTION PURSUANT TO CHAPTER 9.6 OF THE MEMPHIS AND SHELB Y COUNTY UNIFIE D
DEVELOPMENT CODE APPROVING A PLANNED D EVELOPMENT AT THE SUBJECT PROPERTY
LOCATED AT 0 IKEA WAY, KNOWN AS CASE NUMBER PD 2026-005
• This item is a resolution with conditions to allow a hotel as an amendment to PD
2023-313; and
• This resolution, if approved with conditions, will supersede the existing zoning for
this property; and
• The item may require future public improvement contracts.
1
LAND USE CONTROL BOARD RECOMMENDATION
At its regular meeting on Thursday, March 12, 2026 the Memphis and Shelby County Land Use Control
Board held a public hearing on the following application:
CASE NUMBER: PD 2026-001
DEVELOPMENT: Galleria of Memphis Planned Development
LOCATION: 0 Ikea Way
COUNCIL DISTRICT(S): District 1 and Super District 9 – Positions 1, 2, and 3
OWNER/APPLICANT: Brad Smith
REPRESENTATIVE: Mike Davis, The Reaves Firm
REQUEST: Amendment to PD 2013-313 to allow a hotel
EXISTING ZONING: Conservation Agriculture (CA) underlying PD 2013-313 Area A
AREA: +/- 2.39 acres
The following spoke in support: None
The following spoke in opposition: None
The Land Use Control Board reviewed the application and the staff report. A motion was made and
seconded to recommend approval with conditions.
The motion passed by a unanimous vote of 8-0 on the consent agenda.
Respectfully,
Chloe Christion
Planner II
Land Use and Development Services
Division of Planning and Development
Cc: Committee Members
File
2
PD 2026-005
CONDITIONS
Outline Plan Conditions – Revisions
Proposed language is indicated in bold, underline; deletions are indicated in bold strikethrough
Area A-3
I. Uses permitted:
A. Hotel
B. Any use permitted in Parcel I. A
II. Bulk Regulations:
A. The bulk regulations of the CMU-2 District shall apply in addition to the following:
B. Maximum building height of five (5) stories.
C. Maximum height of light standards 30 feet.
III. Signs:
A. The sign regulations of the CMU-2 District as found in UDC Section 4.9 shall apply.
3
All other conditions of this planned development are recommended to be unaltered.
PD 2013-313 OUTLINE PLAN CONDITIONS
4
5
6
7
8
9
OUTLINE PLAN
RESOLUTION PURSUANT TO CHAPTER 9.6 OF THE MEMPHIS AND SHELBY COUNTY
UNIFIED DEVELOPMENT CO DE APPROVING A P LANNED DEVELOPMENT AT THE
SUBJECT PROPERTY LOCATED AT 0 IKEA WAY, KNOWN AS CASE NUMBER PD 2026-001
WHEREAS, Chapter 9.6 of the Memphis and Shelby County Unified Development Code, being a
section of the Joint Ordinance Resolution No. 5367, dated August 10, 2010, authorizes the Council of the
City of Memphis to grant a planned development for certain stated purposes in the various zoning districts;
and
WHEREAS, Brad Smith filed an application with the Memphis and Shelby County Division of
Planning and Development to amend to PD 2013-313 to allow a hotel; and
WHEREAS, the Division of Planning and Development has received and reviewed the application
in accordance with procedures, objectives and standards for planned developments as set forth in Chapter
9.6 with regard to the proposed development's impacts upon surrounding properties, availability of public
facilities, both external and internal circulation, land use compatibility, and that the design and amenities
are consistent with the public interest; and has submitted its findings and recommendation subject to outline
plan conditions concerning the above considerations to the Memphis and Shelby County Land Use Control
Board; and
WHEREAS, a public hearing in relation thereto was held before the Memphis and Shelby County
Land Use Control Board on March 12, 2026, and said Board has submitted its findings and recommendation
subject to outline plan conditions concerning the above considerations to the Council of the City of
Memphis; and
WHEREAS, the Council of the City of Memphis has reviewed the aforementioned application
pursuant to Tennessee Code Annotated Section 13-4- 202(B)(2)(B)(iii) and has determined that said
development is consistent with the Memphis 3.0 General Plan; and
WHEREAS, the Council of the City of Memphis has reviewed the recommendation of the Land
Use Control Board and the report and recommendation of the Division of Planning and Development and
has determined that said development meets the objectives, standards and criteria for a special use permit,
and said development is consistent with the public interests.
NOW, THEREFORE, BE IT RESOLVED, BY THE COUNCIL OF THE CITY OF
MEMPHIS, that, pursuant to Chapter 9.6 of the Memphis and Shelby County Unified Development Code,
a planned development is hereby granted in accordance with the attached outline plan conditions.
BE IT FURTHER RESOLVED , t hat the requirements of said aforementioned clause of the
Unified Development Code shall be deemed to have been complied with; that the outline plan shall bind
the applicant, owner, mortgagee, if any, and the legislative body with respect to the contents of said plan;
and the applicant and/or owner may file a final plan in accordance with said outline plan and the provisions
of Section 9.6.11 of the Unified Development Code.
OUTLINE PLAN CONDITIONS
Area A-3
I. Uses permitted:
A. Hotel
B. Any use permitted in Parcel I. A
II. Bulk Regulations:
A. The bulk regulations of the CMU-2 District shall apply in addition to the following:
B. Maximum building height of five (5) stories.
C. Maximum height of light standards 30 feet.
III. Signs:
A. The sign regulations of the CMU-2 District as found in UDC Section 4.9 shall apply.
All other conditions of this planned development are recommended to be unaltered.
OUTLINE PLAN
ATTEST:
CC: Division of Planning and Development
– Land Use and Development Services
– Office of Construction Enforcement
Staff Writer: Chloe Christion E-mail: chleo.christion@memphistn.gov
AGENDA ITEM: 6 L.U.C.B. MEETING: March 12, 2026
CASE NUMBER: PD 2026-001
DEVELOPMENT: Galleria of Memphis Planned Development
LOCATION: 0 Ikea Way
COUNCIL DISTRICT: District 1 and Super District 9
OWNER/APPLICANT: Brad Smith
REPRESENTATIVE: Mike Davis, The Reaves Firm
REQUEST: Amendment to PD 2013-313 to allow a hotel
EXISTING ZONING: Conservation Agriculture (CA) underlying PD 2013-313 Area A
CONCLUSIONS
1. The concept plan creates a new Area A -3 in the Galleria of Memphis Planned Development in which a
hotel is a permitted use in addition to other uses permitted in Area A of the previous planned
development. Note the previous planned development permits any use allowed by right or via the
Administrative Site Plan Review (ASPR) process in the Commercial Mixed -Use – 2 (CMU -2) District
excluding specific uses such as a church, pawn shop, and vehicle wash. See pages 16-21 for said outline
plan conditions.
2. The amendment requires signs to adhere to the standards o f the Commercial Mixed -Use - 2 (CMU-2)
District and permits a building height of up to five stories. This places any proposed hotel erected on the
site in the height range of existing hotels on Ikea Way and Market Plaza Drive that range from four to
five stories in height.
3. Given the commercial nature of the properties within the Galleria of Memphis Planned Development
and the amount of existing hotels, an amendment to this planned development to allow a hotel is
appropriate and matches the character and rhythm of the surrounding area.
4. The project will not have a substantial or undue adverse effect upon adjacent property, the character of
the neighborhood, traffic conditions, parking, utility facilities and other matters affecting the public
health, safety, and general welfare.
CONSISTENCY WITH MEMPHIS 3.0
This proposal is not applicable to the Memphis 3.0 General Plan per the land use decision criteria.
RECOMMENDATION:
Approval with conditions
Staff Report March 12, 2026
PD 2026-001 Page 2
2
LOCATION MAP
Subject property located within the pink circle
SUBJECT PROPERTY
Staff Report March 12, 2026
PD 2026-001 Page 3
3
PUBLIC NOTICE VICINITY MAP
Subject property outlined in red
PUBLIC NOTICE DETAILS
In accordance with Sub-Section 9.3.4A of the Unified Development Code, a notice of public hearing is required
to be mailed and signage posted. A total of 26 notices were mailed on February 20, 2026 , see page 31 of this
report for a copy of said notice. Additionally, one sign was posted at the subject property, see page 32 of this
report for a copy of the sign affidavit.
NEIGHBORHOOD MEETING
The meeting was held at 6:00 PM on Thursday, February 26, 2026, at Hilton Garden Inn at 7955 Ikea Way.
Staff Report March 12, 2026
PD 2026-001 Page 4
4
AERIAL
Subject property outlined in yellow, imagery from 2025
Staff Report March 12, 2026
PD 2026-001 Page 5
5
ZONING MAP
Subject property highlighted in yellow
Staff Report March 12, 2026
PD 2026-001 Page 6
6
LAND USE MAP
Subject property indicated by a pink star
Staff Report March 12, 2026
PD 2026-001 Page 7
7
SITE PHOTOS
View of subject property from Ikea Way facing south.
Staff Report March 12, 2026
PD 2026-001 Page 8
8
OUTLINE PLAN
Staff Report March 12, 2026
PD 2026-001 Page 9
9
Staff Report March 12, 2026
PD 2026-001 Page 10
10
Staff Report March 12, 2026
PD 2026-001 Page 11
11
LANDSCAPE PLAN
Staff Report March 12, 2026
PD 2026-001 Page 12
12
CASE REVIEW
Request
The request is an amendment to PD 2013-303 to allow a hotel.
Applicability
Staff agrees the applicability standards and criteria as set out in Section 4.10.2 of the Unified Development Code
are or will be met.
4.10.2 Applicability
The governing bodies may, upon proper application, grant a special use permit for a planned development (see
Chapter 9.6) for a tract of any size within the City or for tracts of at least three acres in unincorporated Shelby
County to facilitate the use of flexible techniques of land development and site design, by providing relief from
district requirements designed for conventional developments, and may establish standards and procedures for
planned developments in order to obtain one or more of the following objectives:
A. Environmental design in the development of land that is of a higher quality than is possible under the
regulations otherwise applicable to the property.
B. Diversification in the uses permitted and variation in the relationship of uses, structures, open space and
height of structures in developments intended as cohesive, unified projects.
C. Functional and beneficial uses of open space areas.
D. Preservation of natural features of a development site.
E. Creation of a safe and desirable living environment for residential areas characterized by a unified
building and site development program.
F. Rational and economic development in relation to public services.
G. Efficient and effective traffic circulation, both within and adjacent to the development site, that supports
or enhances the approved transportation network.
H. Creation of a variety of housing compatible with surrounding neighborhoods to provide a greater choice
of types of environment and living units.
I. Revitalization of established commercial centers of integrated design to order to encourage the
rehabilitation of such centers in order to meet current market preferences.
J. Provision in attractive and appropriate locations for business and manufacturing uses in well -designed
buildings and provision of opportunities for employment closer to residence with a reduction in travel
time from home to work.
K. Consistency with the Memphis 3.0 General Plan.
General Provisions
Staff agrees the general provisions standards and criteria as set out in Section 4.10.3 of the Unified Development
Code are or will be met.
4.10.3 General Provisions
The governing bodies may grant a special use permit for a planned development which modifies the applicable
district regulations and other regulations of this development code upon written findings and recommendations
of the Land Use Control Board and the Zoning Administrator which shall be forwarded pursuant to provisions
contained in this Chapter.
A. The proposed development will not unduly injure or damage the use, value and enjoyment of surrounding
Staff Report March 12, 2026
PD 2026-001 Page 13
13
property nor unduly hinder or prevent the development of surrounding property in accordance with the
current development policies and plans of the City and County.
B. An approved water supply, community waste water treatment and disposal, and storm water drainage
facilities that are adequate to serve the proposed development have been or will be provided concurrent
with the development.
C. The location and arrangement of the structures, parking areas, walks, lighting and other service facilities
shall be compatible with the surrounding land uses, and any part of the proposed development not used
for structures, parking and loading areas or access way shall be landscaped or otherwise improved except
where natural features are such as to justify preservation.
D. Any modification of the district standards that would otherwise be applicable to the site are warranted
by the design of the outline plan and the amenities incorporated therein, and are not inconsistent with
the public interest.
E. Homeowners’ associations or some other responsible party shall be required to maintain any and all
common open space and/or common elements.
F. Lots of record are created with the recording of a planned development final plan.
Commercial or Industrial Criteria
Staff agrees the additional planned commercial or industrial development criteria as set out in Section 4.10.5 of
the Unified Development Code are or will be met.
4.10.5 Planned Commercial or Industrial Developments
Approval of a planned commercial or industrial development may be issued by the governing bodies for buildings
or premises to be used for the retail sale of merchandise and services, parking areas, office buildings, hotels and
motels and similar facilities ordinarily accepted as commercial center uses and those industrial uses which can
be reasonably be expected to function in a compatible manner with the other permitted uses in the area. In
addition to the applicable standards and criteria set forth in Section 4.10.3, planned commercial or industrial
developments shall comply with the following standards:
A. Screening
When commercial or industrial structures or uses in a planned commercial or industrial development
abut a residential district or permitted residential buildings in the same development, screening may
be required by the governing bodies.
B. Display of Merchandise
All business, manufacturing and processing shall be conducted, and all merchandise and materials
shall be displayed and stored, within a completely enclosed building or within an open area which is
completely screened from the view of adjacent properties and public rights -of-way, provided,
however, that when an automobile service station or gasoline sales are permitted in a planned
commercial development, gasoline may be sold from pumps outside of a structure.
C. Accessibility
The site shall be accessible from the proposed street network in the vicinity which will be adequate to
carry the anticipated traffic of the proposed development. The streets and driveways on the site of
the proposed development shall be adequate to serve the enterprises located in the proposed
development.
D. Landscaping
Landscaping shall be required to provide screening of objectionable views of uses and the reduction
of noise. High-rise buildings shall be located within the development in such a way as to minimize any
adverse impact on adjoining low-rise buildings.
Staff Report March 12, 2026
PD 2026-001 Page 14
14
Approval Criteria
Staff agrees the approval criteria as set out in Section 9.6.9 of the Unified Development Code are being met.
9.6.9 Approval Criteria
No special use permit or planned development shall be approved unless the following findings are made
concerning the application:
A. The project will not have a substantial or undue adverse effect upon adjacent property, the character of
the neighborhood, traffic conditions, parking, utility facilities and other matters affecting the public
health, safety, and general welfare.
B. The project will be constructed, arranged and operated so as to be compatible with the immediate vicinity
and not interfere with the development and use of adjacent property in accordance with the applicable
district regulations.
C. The project will be served adequately by essential public facilities and services such as streets, parking,
drainage, refuse disposal, fire protection and emergency services, water and sewers; or that the applicant
will provide adequately for such services.
D. The project will not result in the destruction, loss or damage of any feature determined by the governing
bodies to be of significant natural, scenic or historic importance.
E. The project complies with all additional standards imposed on it by any particular provisions authorizing
such use.
F. The request will not adversely affect any plans to be considered (see Chapter 1.9), or violate the character
of existing standards for development of the adjacent properties.
G. The governing bodies may impose conditions to minimize adverse effects on the neighborhood or on
public facilities, and to ensure compatibility of the proposed development with surrounding properties,
uses, and the purpose and intent of this development code.
H. Any decision to deny a special use permit request to place, construct, or modify personal wireless service
facilities shall be in writing and supported by substantial evidence contained in a written record, per the
Telecommunications Act of 1996, 47 USC 332(c)(7)(B)(iii). The review body may not take into account any
environmental or health concerns.
Site Details
Address:
0 Ikea Way
Parcel ID:
096500 00722
Area:
+/- 2.39 acres
Description:
The subject property is known as part of Area A within the Galleria of Memphis Planned Development (PD 2013-
313). The property is vacant and surrounded by commercial land uses including retail and hotel space. The lot
has one street frontage on Ikea Way.
Staff Report March 12, 2026
PD 2026-001 Page 15
15
Site Zoning History
On July 2, 2013, the Council of the City of Memphis approved PD 2013-313 which allowed a planned
development for the subject property at the intersection of Market Plaza Drive and Germantown Parkway. See
pages 22-25 for said resolution.
Concept Plan Review & Analysis
The concept plan creates a new Area A-3 in the Galleria of Memphis Planned Development in which a hotel is a
permitted use in addition to other uses permitted in Area A of the previous planned development. Note the
previous planned development permi ts any use allowed by right or via the Administrative Site Plan Review
(ASPR) process in the Commercial Mixed-Use – 2 (CMU-2) District excluding specific uses such as a church, pawn
shop, and vehicle wash. See pages 16-21 for said outline plan conditions.
The amendment requires signs to adhere to the standards o f the Commercial Mixed -Use -2 (CMU-2) District
and permits a building height of up to five stories. This places any proposed hotel erected on the site in the
height range of existing hotels on Ikea Way and Market Plaza Drive that range from four to five stories in height.
Given the commercial nature of the properties within the Galleria of Memphis Planned Development and the
amount of existing hotels, an amendment to this planned development to allow a hotel is appropriate and
matches the character and rhythm of the surrounding area.
The project will not have a substantial or undue adverse effect upon adjacent property, the character of the
neighborhood, traffic conditions, parking, utility facilities and other matters affecting the public health, safety,
and general welfare.
RECOMMENDATION
Staff recommends approval with revisions to the outline plan conditions.
Outline Plan Conditions – Revisions
Proposed language is indicated in bold, underline; deletions are indicated in bold strikethrough
Area A-3
I. Uses permitted:
A. Hotel
B. Any use permitted in Parcel I. A
II. Bulk Regulations:
A. The bulk regulations of the CMU-2 District shall apply in addition to the following:
B. Maximum building height of five (5) stories.
C. Maximum height of light standards 30 feet.
III. Signs:
A. The sign regulations of the CMU-2 District as found in UDC Section 4.9 shall apply.
Staff Report March 12, 2026
PD 2026-001 Page 16
16
All other conditions of this planned development are recommended to be unaltered.
PD 2013-313 OUTLINE PLAN CONDITIONS
Staff Report March 12, 2026
PD 2026-001 Page 17
17
Staff Report March 12, 2026
PD 2026-001 Page 18
18
Staff Report March 12, 2026
PD 2026-001 Page 19
19
Staff Report March 12, 2026
PD 2026-001 Page 20
20
Staff Report March 12, 2026
PD 2026-001 Page 21
21
Staff Report March 12, 2026
PD 2026-001 Page 22
22
PD 2013-313 APPROVED RESOLUTION
Staff Report March 12, 2026
PD 2026-001 Page 23
23
Staff Report March 12, 2026
PD 2026-001 Page 24
24
Staff Report March 12, 2026
PD 2026-001 Page 25
25
Staff Report March 12, 2026
PD 2026-001 Page 26
26
DEPARTMENTAL COMMENTS
The following comments were provided by agencies to which this application was referred:
City Engineer: See pages 18-20.
County Engineer: No comments received.
City Fire Division:
All design and construction shall comply with the 2021 edition of the International Fire Code with local
amendments and referenced standards.
1. Fire apparatus access shall comply with section 503.
2. Where security gates are installed that affect required fire apparatus access roads, they shall comply with
section 503.6.
3. Fire protection water supplies (including fire hydrants) shall comply with section 507.
4. Where fire apparatus access roads or a water supply for fire protection are required to be installed, such
protection shall be installed and made serviceable prior to and during the time of construction except when
approved alternate methods of protection are provided.
5. IFC 510 In-building two-way emergency responder communication coverage shall be provided in all new and
existing buildings. Buildings and structures that cannot support the required level of coverage shall be
equipped with systems and components to enhance signals and achieve the required level of
communication coverage.
6. A detailed plans review will be conducted by the Memphis Fire Prevention Bureau upon receipt of complete
construction documents. Plans shall be submitted to the Shelby County Office of Code Enforcement.
County Fire Division: No comments received.
City Real Estate: No comments received.
County Health Department: No comments received.
Shelby County Schools: No comments received.
Construction Code Enforcement: No comments received.
Memphis Light, Gas and Water: No comments received.
Office of Sustainability and Resilience: No comments received.
Staff Report March 12, 2026
PD 2026-001 Page 27
27
Office of Comprehensive Planning: No comments received.
Staff Report March 12, 2026
PD 2026-001 Page 28
28
ENGINEERING COMMENTS
CASE 1: PD-26-001 Amend PD-13-313 to allow a hotel
NAME: 0 Ikea Way; 096500 00722
Basin/Lot/CD: Fletcher Creek, 12-A/ 2.39ac/1
1. Standard Public Improvement Contract or Right-Of-Way Permit as required in Section 5.5.5 of the Unified
Development Code.
Sewers:
2. City sanitary sewer capacity is available and needs to meet the requirement of the sewer connection letter
issued on 19 Dec 2025 by the Public Works director.
3. The site is in Fletcher Creek sewer basin. Attached is the letter.
Staff Report March 12, 2026
PD 2026-001 Page 29
29
Roads:
4. The Developer shall be responsible for the repair and/or replacement of all existing curb and gutter along
the frontage of this site as necessary.
5. All existing sidewalks and curb openings along the frontage of this site shall be inspected for ADA
compliance. The developer shall be responsible for any reconstruction or repair necessary to meet City
standards.
Traffic Control Provisions:
6. The developer shall provide a traffic control plan to the city engineer that shows the phasing for each
street frontage during demolition and construction of curb gutter and sidewalk. Upon completion of
sidewalk and curb and gutter improvements, a minimum 5 foot wide pedestrian pathway shall be provided
throughout the remainder of the project. In the event that the existing right of way width does not allow
for a 5 foot clear pedestrian path, an exception may be considered.
7. Any closure of the right of way shall be time limited to the active demolition and construction of sidewalks
and curb and gutter. Continuous unwarranted closure of the right of way shall not be allowed for the
duration of the project. The developer shall provide on the traffic control plan, the time needed per phase
to complete that portion of the work. Time limits will begin on the day of closure and will be monitored by
the Engineering construction inspectors on the job.
8. The developer’s engineer shall submit a Trip Generation Report that documents the proposed land use,
scope and anticipated traffic demand associated with the proposed development. A detailed Traffic Impact
Study will be required when the accepted Trip Generation Report indicates that the number for projected
trips meets or exceeds the criteria listed in Section 210-Traffic Impact Policy for Land Development of the
City of Memphis Division of Engineering Design and Policy Review Manual. Any required Traffic Impact
Study will need to be formally approved by the City of Memphis, Traffic Engineering Department.
Curb Cuts/Access:
9. The City Engineer shall approve the design, number, and location of curb cuts.
10. Any existing nonconforming curb cuts shall be modified to meet current City Standards or closed with
curb, gutter, and sidewalk.
11. Will require engineering ASPR.
Drainage:
12. A grading and drainage plan for the site shall be submitted to the City Engineer for review and approval
prior to recording of the final plat.
13. Drainage improvements, including possible on-site detention, shall be provided under a Standard
Subdivision contract in accordance with Unified Development Code and the City of Memphis/Shelby
County Storm Water Management Manual.
14. Drainage data for assessment of on-site detention requirements shall be submitted to the City Engineer.
Staff Report March 12, 2026
PD 2026-001 Page 30
30
15. The following note shall be placed on the final plat of any development requiring on-site storm water
detention facilities: The areas denoted by "Reserved for Storm Water Detention" shall not be used as a
building site or filled without first obtaining written permission from the City and/or County Engineer. The
storm water detention systems located in these areas, except for those parts located in a public drainage
easement, shall be owned and maintained by the property owner and/or property owners' association.
Such maintenance shall be performed so as to ensure that the system operates in accordance with the
approved plan on file in the City and/or County Engineer's Office. Such maintenance shall include, but not
be limited to removal of sedimentation, fallen objects, debris and trash, mowing, outlet cleaning, and
repair of drainage structures.
16. The developer should be aware of his obligation under 40 CFR 122.26(b)(14) and TCA 69-3-101 et. seq. to
submit a Notice of Intent (NOI) to the Tennessee Division of Water Pollution Control to address the
discharge of storm water associated with the clearing and grading activity on this site.
General Notes:
17. Development is greater than 1 acre and is located within a sensitive drainage basin. Detention and
engineering review are required.
18. No other utilities or services may occupy sanitary sewer easements in private drives and yards except for
crossings.
19. All connections to the sewer shall be at manholes only.
20. All commons, open areas, lakes, drainage detention facilities, private streets, private sewers and private
drainage systems shall be owned and maintained by a Property Owner's Association. A statement to this
effect shall appear on the final plat.
21. Required landscaping shall not be placed on sewer or drainage easements.
Staff Report March 12, 2026
PD 2026-001 Page 31
31
MAILED PUBLIC NOTICE
Staff Report March 12, 2026
PD 2026-001 Page 32
32
SIGN AFFIDAVIT
Staff Report March 12, 2026
PD 2026-001 Page 33
33
APPLICATION
Staff Report March 12, 2026
PD 2026-001 Page 34
34
Staff Report March 12, 2026
PD 2026-001 Page 35
35
Staff Report March 12, 2026
PD 2026-001 Page 36
36
Staff Report March 12, 2026
PD 2026-001 Page 37
37
OWNER AFFIDAVIT
Staff Report March 12, 2026
PD 2026-001 Page 38
38
LETTER OF INTENT
Staff Report March 12, 2026
PD 2026-001 Page 39
39
LETTERS RECEIVED
No letters received at the time of completion of this report.
East Service Center: 6465 Mullins Station Rd; Memphis,
Tennessee
38134
Downtown Service Center: 125 N. Main Street;
Memphis, T
ennessee 38103
website: www.develop901.com
Memphis and Shelby County Division of
Planning and Development
Record Summary for Planned Development
Record Detail Information
Record T
ype: Planned Development Record Status: Additional Info Required
Opened Date:
January 28, 2026
Record Number: PD 2026-001
Record Name: Galleria of Memphis PD Amendment
Expiration Date:
Description of Work: On behalf of StoneCrest Investments, the applicant, and ownership group GRH
Glenwood LLC, MRH Venture Capital LLC, Stephens Holdings LLC, MEMTEX Development No 1 LLC,
and Ryan Family Ventures LLC, we are pleased to submit the attached amendment to the Galleria of
Memphis PD (PD 13-0313).
The purpose of the application is to modify the outline plan to create Area A-3 within Parcel 1, a 2.39
acre lot consisting entirely of Parcel No. 096500 00722 to allow for hotel use with a height of 5 stories.
We had a pre-application meeting on January 9, 2026.
Parent Record Number:
Address:
0 Ikea Way 38016
Owner Information
Primary
Owner Name
Owner Address Owner Phone
Y GRH GLENWOOD LLC AND MRH VENTURE CAPIT
AL
595 ROUND ROCK WEST DR, ROUND ROCK, TX 78681
Parcel Information
096500 00722
Data Fields
PREAPPLICA
TION MEETING
Name of DPD Planner Chloe
Date of Meeting 01/09/2026
Pre-application Meeting
Type In Person
GENERAL PROJECT INFORMATION
Page 1 of 4 PD 2026-001
Planned Development Type Amendment to Existing PD
Previous Docket / Case Number 13-313
08-326
04-312
90-315 CC
Medical Overlay / Uptown No
If this development is located in unincorporated
Shelby County, is the tract at least three acres?
(Note a tract of less than three acres is not
eligible for a planned development in
unincorporated Shelby County)
N/A
Is this application in response to a citation, stop
work order, or zoning letter
No
If yes, please provide a copy of the citation, stop
work order, and/or zoning letter along with any
other relevant information
-
APPROVAL CRITERIA
UDC Sub-Section 9.6.9A The immediately adjacent property has 3 hotels: two
to the west at four and five stories and one to the
south at four stories. There is Ikea to the northwest
and a retail center to the east. Directly north is a
large stormwater detention pond associated with
another retail center.
A maximum five-story hotel is
in keeping with the neighborhood. The property is
located on a fully-improved street and all public
utilities are readily available.
UDC Sub-Section 9.6.9B Correct. The applicant plans to build a maximum
five-story hotel on this site, which is consistent with
surrounding property, most of which are stand alone
and fully developed.
UDC Sub-Section 9.6.9C The area is embedded within an existing
commercial area and as such is supported by fully
improved infrastructure and utilities.
UDC Sub-Section 9.6.9D The site is an open field with no known scenic or
historical features.
UDC Sub-Section 9.6.9E With the granting of the PD amendment to the
outline plan for the hotel and to allow five stories in
height, this project complies with UDC standards.
UDC Sub-Section 9.6.9F The project complies with building and zoning code,
is compatible with adjacent property, and will cause
no violations.
GENERAL PROVISIONS
UDC Sub-Section 4.10.3A Correct.
B) An approved water supply, community waste
water treatment and disposal, and storm water
drainage facilities that are adequate to serve the
proposed development have been or will be
provided concurrent with the development
All utilities are existing on or near this property.
Page 2 of 4 PD 2026-001
GENERAL PROVISIONS
C) The location and arrangement of the
structures, parking and loading areas, walks,
lighting and other service facilities shall be
compatible with the surrounding land uses, and
any part of the proposed development not used
for such facilities shall be landscaped or
otherwise improved except where natural
features are such as to justify preservation
Correct
D) Any modification of the district standards that
would otherwise be applicable to the site are
warranted by the design of the outline plan and
the amenities incorporated therein, and are not
inconsistent with the public interest
Correct
E) Homeowners’ associations or some other
responsible party shall be required to maintain
any and all common open space and/or common
elements
Understood.
F) Lots of record are created with the recording
of a planned development final plan
Understood.
GIS INFORMATION
Case Layer PD16-010, PD13-313, PD04-312
Central Business Improvement District No
Class C
Downtown Fire District No
Historic District -
Land Use V
ACANT
Municipality -
Overlay/Special Purpose District Fletcher Creek Overlay
Zoning CA
State Route -
Lot -
Subdivision GALLERIA OF MEMPHIS PD AMENDED PAR 1
AND
Planned Development District -
Wellhead Protection Overlay District No
County Commission District -
City Council District -
City Council Super District -
Contact Information
Page 3 of 4 PD 2026-001
BRAD SMITH
595 ROUND ROCK WEST
DR, MEMTEX DEVELOPMENT # 1, ROUND ROCK, TX, ROUND ROCK, TX, 78681
-
APPLICANT
Name
Address
Phone
Contact Type
GREG BARTLETT
6800 POPLAR
AVE,
(901)761-2016
ARCHITECT
/ ENGINEER /
SURVEYOR
Name
Address
Phone
Contact Type
CHRISTINE DONHARDT
6800 POPLAR
AVE,
(901)761-2016
MANAGER
Name
Address
Phone
Contact Type
BRAD SMITH
595 ROUND ROCK WEST
DR, MEMTEX DEVELOPMENT # 1, ROUND ROCK, TX, ROUND ROCK, TX, 78681
(901)761-2016
PROPER
TY OWNER OF
RECORD
Name
Address
Phone
Contact Type
MIKE DAVIS
(901)761-2016
REPRESENT
ATIVE
Name
Address
Phone
Contact Type
Fee Information
Date AssessedBalanceStatusFeesQuantityFee ItemInvoice #
01/28/20260.00INVOICED0.001Credit Card Use Fee (.026
x fee)
1703562
01/29/20260.00INVOICED1,500.001Planned Development - 5
acres or less
1703585
Total Fee Invoiced
: $1,500.00 Total Balance: $0.00
Payment Information
Payment
Amount Method of Payment
Check$1,500.00
Page 4 of 4 PD 2026-001
6800 Poplar Avenue, Suite 101 Memphis, TN 38138 T. 901.761.2016 / F. 901.763.2847
January 30, 2026
Mr. Brett Ragsdale
Division of Planning and Development
125 N. Main, Ste. 477
Memphis, TN 38103
RE: Galleria of Memphis PD
Dear Brett,
On behalf of Stone Crest Investments, the applicant, and ownership group GRH Glenwood LLC, MRH
Venture Capital LLC, Stephens Holdings LLC, MEMTEX Development No 1 LLC, and Ryan Family Ventures
LLC, we are pleased to submit the attached amendment to the Galleria of Memphis PD (PD 13-0313).
The purpose of the application is to modify the outline plan to create Area A-3 within Parcel 1, a 2.39 acre
lot consisting entirely of Parcel No. 096500 00722 to allow for hotel use with a height of 5 stories. We
had a pre-application meeting on January 9, 2026.
Sincerely,
Mike Davis, R.L.A.
Principal
IKEA WAY
MARKET FARMS DRIVE
BELLEVUE PARKWAY
NORTH GERMANTOWN PARKWAY
ROCKCREEK PKWY.
VARNAVAS
PARCEL I
AREA F
PARCEL I
AREA A
PARCEL I
AREA A
PARCEL I
AREA B-2
PARCEL I
AREA B-1
PARCEL I
AREA D-2
PARCEL I
AREA D-1
PARCEL I
AREA D
PARCEL I
AREA A-3
±2.4 AC.
15' PRIVATE DRAIN ESM'T
(P.B. 237 P.G. 37)
15' PUBLIC SEWER ESM'T
(P.B. 222 P.G. 51)
S86°28'25"E
173.00'
S3°30'40"W 55.76'
N86°29'45"W 172.88'
S3°30'40"W
455.39'
N3°30'40"E
610.05'
RAD=67.00'
ARC=111.15'
TAN=73.18'
MEMPHIS, TENNESSEE 250.34 ACRES
DEVELOPER: STONECREST INVESTMENTS ENGINEER: THE REAVES FIRM
JANUARY 2026 SCALE: 1" = 200' SHEET 1 OF 7
GALLERIA OF MEMPHIS PLANNED DEVELOPMENT
100-YEAR FLOOD ELEV: 280.0 ± FEMA MAP PANEL NO: 310 G, 316 G FEMA MAP DATE: FEB. 6, 2013
6800 Poplar Avenue, Suite 101 Memphis, TN 38138
901.761.2016 Fax: 901.763.2847
www.ReavesFirm.com
Engineering
Planning
Landscape Architecture
Land Surveying
The
Reaves
Firm
INCORPORATED
OUTLINE PLAN
P.D. 26-______ (FORMERLY P.D. 13-313, P.D. 08-326, P.D. 04-312, & P.D. 90-315 CC)
GRAPHIC SCALE IN FEET
North
0 200
SCALE: 1" = 200'
200
JOB # 25-0216
THIS SHEET IS BEING ADDED TO SHOW THE CREATION OF AREA A-3 IN PARCEL I.
PROPOSED CONDITIONS FOR AREA A-3 ARE LISTED BELOW. UNLESS OTHERWISE
SPECIFIED, THE EXISTING CONDITIONS OF AREA A SHALL APPLY TO AREA A-3. ALL
OTHER CONDITIONS FOR THIS PLANNED DEVELOPMENT ARE RECOMMENDED TO
BE UNALTERED.
SHEETS 2-4 ARE TAKEN FROM THE OUTLINE PLAN RECORDED IN PL. BK. 267, PG. 1.
PD 26- ____ (Galleria of Memphis Planned Development Amendment)
Outline Plan Conditions for Area A-3
I. Uses permitted:
A. Hotel and any use permitted in Area A.
II. Bulk Regulation:
A. Maximum five (5) stories
B. Maximum height of light standards 30 feet.
III. Signs:
A. Signs as allowed in CMU-2 District
6800 Poplar Avenue, Suite 101 Memphis, TN 38138
901.761.2016 Fax: 901.763.2847
www.ReavesFirm.com
Engineering
Planning
Landscape Architecture
Land Surveying
The
Reaves
Firm
INCORPORATED
MEMPHIS, TENNESSEE 250.34 ACRES
DEVELOPER: STONECREST INVESTMENTS ENGINEER: THE REAVES FIRM
JANUARY 2026 SCALE: N/A SHEET 5 OF 7
GALLERIA OF MEMPHIS PLANNED DEVELOPMENT
100-YEAR FLOOD ELEV: 280.0 ± FEMA MAP PANEL NO: 310 G, 316 G FEMA MAP DATE: FEB. 6, 2013
OUTLINE PLAN
P.D. 26-______ (FORMERLY P.D. 13-313, P.D. 08-326, P.D. 04-312, & P.D. 90-315 CC)
JOB # 25-0216
“ ”
“ ”
ç
ç
“
”
“
”
·
·
·
·
·
·
·
·
·
·
6800 Poplar Avenue, Suite 101 Memphis, TN 38138
901.761.2016 Fax: 901.763.2847
www.ReavesFirm.com
Engineering
Planning
Landscape Architecture
Land Surveying
The
Reaves
Firm
INCORPORATED
MEMPHIS, TENNESSEE 250.34 ACRES
DEVELOPER: STONECREST INVESTMENTS ENGINEER: THE REAVES FIRM
JANUARY 2026 SCALE: N/A SHEET 6 OF 7
GALLERIA OF MEMPHIS PLANNED DEVELOPMENT
100-YEAR FLOOD ELEV: 280.0 ± FEMA MAP PANEL NO: 310 G, 316 G FEMA MAP DATE: FEB. 6, 2013
OUTLINE PLAN
P.D. 26-______ (FORMERLY P.D. 13-313, P.D. 08-326, P.D. 04-312, & P.D. 90-315 CC)
JOB # 25-0216
ENGINEER'S CERTIFICATE
I hereby certify that this plat is true and correct, is in conformance with the design
requirements of the Memphis and Shelby County Unified Development Code, the
specific conditions imposed on this development, and takes into account all
applicable federal, state and local building laws and regulations.
By: (Seal) Date: .
Tennessee License No. .
LAND USE AND DEVELOPMENT SERVICES CERTIFICATE
This final plat conforms with the planned development acted on by the Land Use Control
Board on and approved by the Council of the City of Memphis
on .
By: . Date: .
Zoning Administrator
LUDS: . Date: .
SURVEYOR'S CERTIFICATE
I hereby certify that this is a category 1 survey and that the precision of the
unadjusted survey is 1: 10,000 or greater; that this plat has been prepared
by me or under my individual supervision and conforms with applicable state laws,
the Memphis and Shelby County Unified Development Code, and specific
conditions imposed on this development relating to the practice of surveying.
By: (Seal) Date: .
Tennessee License No. .
NOTARY'S CERTIFICATE
State of Tennessee
County of Shelby
Before me, the undersigned, a Notary Public in and for the said State and County at
Memphis, duly commissioned and qualified, personally appeared with
whom I am personally acquainted, and who upon his oath acknowledged himself to be
the of , the within named bargainer, and that
he executed the foregoing instrument for the purpose therein contained.
In witness whereof, I have hereunto set my hand and affixed my notarial seal at my office
this day of , 2026.
Notary Public .
My Commission Expires .
OWNER'S CERTIFICATE
We, , the undersigned owner of the property shown, hereby adopt
this plat as our plan of development and dedicate the streets, right-of-way, and grant the
easements as shown and/or described to public use forever. We certify that we are the
owners of the said property in fee simple, duly authorized to act, and that said property is
not encumbered by any taxes or mortgages which have become due and payable.
Signature: .
NOTARY'S CERTIFICATE
State of Tennessee
County of Shelby
Before me, the undersigned, a Notary Public in and for the said State and County at
Memphis, duly commissioned and qualified, personally appeared with
whom I am personally acquainted, and who upon his oath acknowledged himself to be
the of , the within named bargainer, and that
he executed the foregoing instrument for the purpose therein contained.
In witness whereof, I have hereunto set my hand and affixed my notarial seal at my office
this day of , 2026.
Notary Public .
My Commission Expires .
OWNER'S CERTIFICATE
We, , the undersigned owner of the property shown, hereby adopt
this plat as our plan of development and dedicate the streets, right-of-way, and grant the
easements as shown and/or described to public use forever. We certify that we are the
owners of the said property in fee simple, duly authorized to act, and that said property is
not encumbered by any taxes or mortgages which have become due and payable.
Signature: .
NOTARY'S CERTIFICATE
State of Tennessee
County of Shelby
Before me, the undersigned, a Notary Public in and for the said State and County at
Memphis, duly commissioned and qualified, personally appeared with
whom I am personally acquainted, and who upon his oath acknowledged himself to be
the of , the within named bargainer, and that
he executed the foregoing instrument for the purpose therein contained.
In witness whereof, I have hereunto set my hand and affixed my notarial seal at my office
this day of , 2026.
Notary Public .
My Commission Expires .
OWNER'S CERTIFICATE
We, , the undersigned owner of the property shown, hereby adopt
this plat as our plan of development and dedicate the streets, right-of-way, and grant the
easements as shown and/or described to public use forever. We certify that we are the
owners of the said property in fee simple, duly authorized to act, and that said property is
not encumbered by any taxes or mortgages which have become due and payable.
Signature: .
NOTARY'S CERTIFICATE
State of Tennessee
County of Shelby
Before me, the undersigned, a Notary Public in and for the said State and County at
Memphis, duly commissioned and qualified, personally appeared with
whom I am personally acquainted, and who upon his oath acknowledged himself to be
the of , the within named bargainer, and that
he executed the foregoing instrument for the purpose therein contained.
In witness whereof, I have hereunto set my hand and affixed my notarial seal at my office
this day of , 2026.
Notary Public .
My Commission Expires .
OWNER'S CERTIFICATE
We, , the undersigned owner of the property shown, hereby adopt
this plat as our plan of development and dedicate the streets, right-of-way, and grant the
easements as shown and/or described to public use forever. We certify that we are the
owners of the said property in fee simple, duly authorized to act, and that said property is
not encumbered by any taxes or mortgages which have become due and payable.
Signature: .
6800 Poplar Avenue, Suite 101 Memphis, TN 38138
901.761.2016 Fax: 901.763.2847
www.ReavesFirm.com
Engineering
Planning
Landscape Architecture
Land Surveying
The
Reaves
Firm
INCORPORATED
MEMPHIS, TENNESSEE 250.34 ACRES
DEVELOPER: STONECREST INVESTMENTS ENGINEER: THE REAVES FIRM
JANUARY 2026 SCALE: N/A SHEET 7 OF 7
GALLERIA OF MEMPHIS PLANNED DEVELOPMENT
100-YEAR FLOOD ELEV: 280.0 ± FEMA MAP PANEL NO: 310 G, 316 G FEMA MAP DATE: FEB. 6, 2013
OUTLINE PLAN
P.D. 26-______ (FORMERLY P.D. 13-313, P.D. 08-326, P.D. 04-312, & P.D. 90-315 CC)
JOB # 25-0216
IKEA WAY
MARKET FARMS DRIVE
BELLEVUE PARKWAY
NORTH GERMANTOWN PARKWAY
ROCKCREEK PKWY.
VARNAVAS
PARCEL I
AREA F
PARCEL I
AREA A
PARCEL I
AREA A
PARCEL I
AREA B-2
PARCEL I
AREA B-1
PARCEL I
AREA D-2
PARCEL I
AREA D-1
PARCEL I
AREA D
PARCEL I
AREA A-3
±2.4 AC.
15' PRIVATE DRAIN ESM'T
(P.B. 237 P.G. 37)
15' PUBLIC SEWER ESM'T
(P.B. 222 P.G. 51)
S86°28'25"E
173.00'
S3°30'40"W 55.76'
N86°29'45"W 172.88'
S3°30'40"W
455.39'
N3°30'40"E
610.05'
RAD=67.00'
ARC=111.15'
TAN=73.18'
MEMPHIS, TENNESSEE 250.34 ACRES
DEVELOPER: STONECREST INVESTMENTS ENGINEER: THE REAVES FIRM
JANUARY 2026 SCALE: 1" = 200' SHEET 1 OF 7
GALLERIA OF MEMPHIS PLANNED DEVELOPMENT
100-YEAR FLOOD ELEV: 280.0 ± FEMA MAP PANEL NO: 310 G, 316 G FEMA MAP DATE: FEB. 6, 2013
6800 Poplar Avenue, Suite 101 Memphis, TN 38138
901.761.2016 Fax: 901.763.2847
www.ReavesFirm.com
Engineering
Planning
Landscape Architecture
Land Surveying
The
Reaves
Firm
INCORPORATED
OUTLINE PLAN
P.D. 26-______ (FORMERLY P.D. 13-313, P.D. 08-326, P.D. 04-312, & P.D. 90-315 CC)
GRAPHIC SCALE IN FEET
North
0 200
SCALE: 1" = 200'
200
JOB # 25-0216
THIS SHEET IS BEING ADDED TO SHOW THE CREATION OF AREA A-3 IN PARCEL I.
PROPOSED CONDITIONS FOR AREA A-3 ARE LISTED BELOW. UNLESS OTHERWISE
SPECIFIED, THE EXISTING CONDITIONS OF AREA A SHALL APPLY TO AREA A-3. ALL
OTHER CONDITIONS FOR THIS PLANNED DEVELOPMENT ARE RECOMMENDED TO
BE UNALTERED.
SHEETS 2-4 ARE TAKEN FROM THE OUTLINE PLAN RECORDED IN PL. BK. 267, PG. 1.
PD 26- ____ (Galleria of Memphis Planned Development Amendment)
Outline Plan Conditions for Area A-3
I. Uses permitted:
A. Hotel and any use permitted in Area A.
II. Bulk Regulation:
A. Maximum five (5) stories
B. Maximum height of light standards 30 feet.
III. Signs:
A. Signs as allowed in CMU-2 District
6800 Poplar Avenue, Suite 101 Memphis, TN 38138
901.761.2016 Fax: 901.763.2847
www.ReavesFirm.com
Engineering
Planning
Landscape Architecture
Land Surveying
The
Reaves
Firm
INCORPORATED
MEMPHIS, TENNESSEE 250.34 ACRES
DEVELOPER: STONECREST INVESTMENTS ENGINEER: THE REAVES FIRM
JANUARY 2026 SCALE: N/A SHEET 5 OF 7
GALLERIA OF MEMPHIS PLANNED DEVELOPMENT
100-YEAR FLOOD ELEV: 280.0 ± FEMA MAP PANEL NO: 310 G, 316 G FEMA MAP DATE: FEB. 6, 2013
OUTLINE PLAN
P.D. 26-______ (FORMERLY P.D. 13-313, P.D. 08-326, P.D. 04-312, & P.D. 90-315 CC)
JOB # 25-0216
“ ”
“ ”
ç
ç
“
”
“
”
·
·
·
·
·
·
·
·
·
·
6800 Poplar Avenue, Suite 101 Memphis, TN 38138
901.761.2016 Fax: 901.763.2847
www.ReavesFirm.com
Engineering
Planning
Landscape Architecture
Land Surveying
The
Reaves
Firm
INCORPORATED
MEMPHIS, TENNESSEE 250.34 ACRES
DEVELOPER: STONECREST INVESTMENTS ENGINEER: THE REAVES FIRM
JANUARY 2026 SCALE: N/A SHEET 6 OF 7
GALLERIA OF MEMPHIS PLANNED DEVELOPMENT
100-YEAR FLOOD ELEV: 280.0 ± FEMA MAP PANEL NO: 310 G, 316 G FEMA MAP DATE: FEB. 6, 2013
OUTLINE PLAN
P.D. 26-______ (FORMERLY P.D. 13-313, P.D. 08-326, P.D. 04-312, & P.D. 90-315 CC)
JOB # 25-0216
ENGINEER'S CERTIFICATE
I hereby certify that this plat is true and correct, is in conformance with the design
requirements of the Memphis and Shelby County Unified Development Code, the
specific conditions imposed on this development, and takes into account all
applicable federal, state and local building laws and regulations.
By: (Seal) Date: .
Tennessee License No. .
LAND USE AND DEVELOPMENT SERVICES CERTIFICATE
This final plat conforms with the planned development acted on by the Land Use Control
Board on and approved by the Council of the City of Memphis
on .
By: . Date: .
Zoning Administrator
LUDS: . Date: .
SURVEYOR'S CERTIFICATE
I hereby certify that this is a category 1 survey and that the precision of the
unadjusted survey is 1: 10,000 or greater; that this plat has been prepared
by me or under my individual supervision and conforms with applicable state laws,
the Memphis and Shelby County Unified Development Code, and specific
conditions imposed on this development relating to the practice of surveying.
By: (Seal) Date: .
Tennessee License No. .
NOTARY'S CERTIFICATE
State of Tennessee
County of Shelby
Before me, the undersigned, a Notary Public in and for the said State and County at
Memphis, duly commissioned and qualified, personally appeared with
whom I am personally acquainted, and who upon his oath acknowledged himself to be
the of , the within named bargainer, and that
he executed the foregoing instrument for the purpose therein contained.
In witness whereof, I have hereunto set my hand and affixed my notarial seal at my office
this day of , 2026.
Notary Public .
My Commission Expires .
OWNER'S CERTIFICATE
We, , the undersigned owner of the property shown, hereby adopt
this plat as our plan of development and dedicate the streets, right-of-way, and grant the
easements as shown and/or described to public use forever. We certify that we are the
owners of the said property in fee simple, duly authorized to act, and that said property is
not encumbered by any taxes or mortgages which have become due and payable.
Signature: .
NOTARY'S CERTIFICATE
State of Tennessee
County of Shelby
Before me, the undersigned, a Notary Public in and for the said State and County at
Memphis, duly commissioned and qualified, personally appeared with
whom I am personally acquainted, and who upon his oath acknowledged himself to be
the of , the within named bargainer, and that
he executed the foregoing instrument for the purpose therein contained.
In witness whereof, I have hereunto set my hand and affixed my notarial seal at my office
this day of , 2026.
Notary Public .
My Commission Expires .
OWNER'S CERTIFICATE
We, , the undersigned owner of the property shown, hereby adopt
this plat as our plan of development and dedicate the streets, right-of-way, and grant the
easements as shown and/or described to public use forever. We certify that we are the
owners of the said property in fee simple, duly authorized to act, and that said property is
not encumbered by any taxes or mortgages which have become due and payable.
Signature: .
NOTARY'S CERTIFICATE
State of Tennessee
County of Shelby
Before me, the undersigned, a Notary Public in and for the said State and County at
Memphis, duly commissioned and qualified, personally appeared with
whom I am personally acquainted, and who upon his oath acknowledged himself to be
the of , the within named bargainer, and that
he executed the foregoing instrument for the purpose therein contained.
In witness whereof, I have hereunto set my hand and affixed my notarial seal at my office
this day of , 2026.
Notary Public .
My Commission Expires .
OWNER'S CERTIFICATE
We, , the undersigned owner of the property shown, hereby adopt
this plat as our plan of development and dedicate the streets, right-of-way, and grant the
easements as shown and/or described to public use forever. We certify that we are the
owners of the said property in fee simple, duly authorized to act, and that said property is
not encumbered by any taxes or mortgages which have become due and payable.
Signature: .
NOTARY'S CERTIFICATE
State of Tennessee
County of Shelby
Before me, the undersigned, a Notary Public in and for the said State and County at
Memphis, duly commissioned and qualified, personally appeared with
whom I am personally acquainted, and who upon his oath acknowledged himself to be
the of , the within named bargainer, and that
he executed the foregoing instrument for the purpose therein contained.
In witness whereof, I have hereunto set my hand and affixed my notarial seal at my office
this day of , 2026.
Notary Public .
My Commission Expires .
OWNER'S CERTIFICATE
We, , the undersigned owner of the property shown, hereby adopt
this plat as our plan of development and dedicate the streets, right-of-way, and grant the
easements as shown and/or described to public use forever. We certify that we are the
owners of the said property in fee simple, duly authorized to act, and that said property is
not encumbered by any taxes or mortgages which have become due and payable.
Signature: .
6800 Poplar Avenue, Suite 101 Memphis, TN 38138
901.761.2016 Fax: 901.763.2847
www.ReavesFirm.com
Engineering
Planning
Landscape Architecture
Land Surveying
The
Reaves
Firm
INCORPORATED
MEMPHIS, TENNESSEE 250.34 ACRES
DEVELOPER: STONECREST INVESTMENTS ENGINEER: THE REAVES FIRM
JANUARY 2026 SCALE: N/A SHEET 7 OF 7
GALLERIA OF MEMPHIS PLANNED DEVELOPMENT
100-YEAR FLOOD ELEV: 280.0 ± FEMA MAP PANEL NO: 310 G, 316 G FEMA MAP DATE: FEB. 6, 2013
OUTLINE PLAN
P.D. 26-______ (FORMERLY P.D. 13-313, P.D. 08-326, P.D. 04-312, & P.D. 90-315 CC)
JOB # 25-0216
City Hall – 125 N. Main Street, Suite 468 – Memphis, Tennessee 38103 – (901) 636-6619
March 12, 2026
Christine Donhardt
The Reaves Firm, Inc.
6800 Poplar Ave., Suite 101
Memphis, TN 38138
Sent via electronic mail to: cdonhardt@thereavesfirm.com
Galleria of Memphis Planned Development
Case Number: PD 2026-001
LUCB Recommendation: Approval with conditions
Dear applicant,
On Thursday, March 12, 202 6, t he Memphis and Shelby County Land Use Control Board
recommended approval of your planned development amendment application for the Galleria of
Memphis Planned Development, subject to the attached outline plan conditions.
This application will be forwarded, for final action, to the Council of the City of Memphis. The Council
will review your application in a committee meeting prior to voting on it in a public hearing. The
applicant or the applicant’s representative(s) shall be in attendance at all meetings and hearings.
It is the applicant’s responsibility to contact the City Council Records Office to determine when the
application is scheduled to be heard at committee and in public session. The City Council Records
Office may be reached at (901) 636-6792.
If for some reason you choose to withdraw your application, a letter should be mailed to the Land
Use and Development Services Department of the Division of Planning and Development at the
address provided above or emailed to the address provided below.
If you have questions regarding this matter, please feel free to contact me at (901) 636-6619 or via
email at chloe.christion@memphistn.gov.
Letter to Applicant
PD 2026-001
Page 2 of 2
Respectfully,
Chloe Christion
Planner II
Land Use and Development Services
Division of Planning and Development
Cc: Dianne Higgs – The Reaves Firm
File
Outline Plan Conditions – Revisions
Proposed language is indicated in bold, underline; deletions are indicated in bold strikethrough
Area A-3
I. Uses permitted:
A. Hotel
B. Any use permitted in Parcel I. A
II. Bulk Regulations:
A. The bulk regulations of the CMU-2 District shall apply in addition to the following:
B. Maximum building height of five (5) stories.
C. Maximum height of light standards 30 feet.
III. Signs:
A. The sign regulations of the CMU-2 District as found in UDC Section 4.9 shall apply.
All other conditions of this planned development are recommended to be unaltered.
CITY OF MEMPHIS
COUNCIL AGENDA CHECK OFF SHEET
___________________________________________________________________________________
| ONE ORIGINAL | Planning & Development
| ONLY STAPLED | DIVISION
|TO DOCUMENTS| Planning & Zoning COMMITTEE: 03/24/2026
DATE
PUBLIC SESSION: 04/14/2026
DATE
ITEM (CHECK ONE)
ORDINANCE X RESOLUTION X REQUEST FOR PUBLIC HEARING
= = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = =
ITEM DESCRIPTION: Resolution approving the request to close and vacate the public -right-of-way of a north -south public alley
known as Litty Place that has an east -west stub at its midpoint heading eastward. , known as case number SAC
25-006
CASE NUMBER: SAC 25-006
LOCATION: East of Kansas St., south of W Georgia Ave., north of W Carolina Ave., and west of Florida St.
COUNCIL DISTRICTS: District 7 and Super District 8
OWNER/APPLICANT: Charles Shoffner
REPRESENTATIVES: Matthew Hudgins
REQUEST: Close and vacate the public -right-of-way of a north -south public alley known as Litty Place that has an east -
west stub at it's midpoint heading eastward and vacate public right-of-way of an east-west public alley
AREA: +/-0.20 acres
RECOMMENDATION: The Division of Planning and Development recommended Approval with conditions
The Land Use Control Board recommended Approval with conditions
RECOMMENDED COUNCIL ACTION: Public Hearing Not Required
= = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = =
PRIOR ACTION ON ITEM:
(1) APPROVAL - (1) APPROVED (2) DENIED
03/09/2026 DATE
(1) Land Use Control Board ORGANIZATION - (1) BOARD / COMMISSION
(2) GOV’T. ENTITY (3) COUNCIL COMMITTEE
= = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = =
FUNDING:
(2) REQUIRES CITY EXPENDITURE - (1) YES (2) NO
$ AMOUNT OF EXPENDITURE
$ REVENUE TO BE RECEIVED
SOURCE AND AMOUNT OF FUNDS
$ OPERATING BUDGET
$ CIP PROJECT #_______________________________
$ FEDERAL/STATE/OTHER
= = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = =
ADMINISTRATIVE APPROVAL: DATE POSITION
_____________________________________________ ____________ PLANNER
_____________________________________________ ____________ DEPUTY ADMINISTRATOR
_____________________________________________ ____________ ADMINISTRATOR
_____________________________________________ ____________ DIRECTOR (JOINT APPROVAL)
_____________________________________________ ____________ COMPTROLLER
_____________________________________________ ____________ FINANCE DIRECTOR
_____________________________________________ ____________ CITY ATTORNEY
= = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = =
_____________________________________________ ____________ CHIEF ADMINISTRATIVE OFFICER
_____________________________________________ ____________ COMMITTEE CHAIRMAN
03/09/2027
03/16/2026
Memphis City Council
Summary Sheet
SAC 2025-006
RESOLUTION APPROVING THE REQUEST TO CLOSE AND VACATE THE PUBLIC -RIGHT-OF-
WAY OF A NORTH -SOUTH PUBLIC ALLEY KNOWN AS LITTY PLACE THAT HAS AN EAST -
WEST STUB AT ITS MIDPOINT HEADING EASTWARD. , KNOWN AS CASE NUMBER SAC 25-
006
• This item is a resolution with conditions to allow the above; and
• This item may require a new public improvement contract.
1
LAND USE CONTROL BOARD RECOMMENDATION
At its regular meeting on Thursday, February 12, 2026, the Memphis and Shelby County Land Use Control
Board held a public hearing on the following application:
CASE NUMBER: SAC 25-006
LOCATION: East of Kansas St., south of W Georgia Ave., north of W Carolina Ave.,
and west of Florida St.
COUNCIL DISTRICT(S): District 7, Super District 8 – Positions 1, 2, and 3
OWNER/APPLICANT: Charles Shoffner
REPRESENTATIVE: Matthew Hudgins
REQUEST: Close and vacate the public-right-of-way of a north-south public alley
known as Litty Place that has an east -west stub at it's midpoint
heading eastward
EXISTING ZONING: Bluffview Residential District – (R-B)
AREA: 0.20 acres
The following spoke in support: None
The following spoke in opposition: None
The Land Use Control Board reviewed the application and the staff report . A motion was made and
seconded to recommend approval with conditions of the application.
The motion passed by a unanimous vote of 10-0 on the consent agenda.
Respectfully,
Travian Smith
Planner I
Land Use and Development Services
Division of Planning and Development
Cc: Committee Members
File
2
SAC 25-006
CONDITIONS
1. The applicant shall comply with all City standards to the satisfaction of the City Engineer and City Fire
Department.
2. Provide easements for existing sanity sewers, drainage facilities, and other utilities or relocate at
developer’s expense.
3. The applicant shall comply with all conditions of the closure within three years of the conditional
approval of the closure by the Council of the City of Memphis. The Land Use Control Board may grant
extensions to this date as Major Modifications as outlin ed in Section 9.8.6 of the UDC. Provide
easements for existing sanitary sewers, drainage facilities, and other utilities or relocate at developer’s
expense.
3
CLOSURE PLAT
RESOLUTION
RESOLUTION APPROVING THE REQUEST TO CLOSE AND
VACATE THE PUBLIC -RIGHT-OF-WAY OF A NORTH -SOUTH PUBLIC ALLEY
KNOWN AS LITTY PLACE THAT HAS AN EAST -WEST STUB AT ITS MIDPOINT
HEADING EASTWARD.
WHEREAS, the City of Memphis is the owner of real property known as the east-west
public-right-of-way of a north-south public alley known as Litty Place in Memphis, Tennessee and
being more particularly described as follows:
Beginning at a point in the north line of West Carolina Avenue (65' R.O.W.), said point being
located 137.50 feet east of the intersection of the north line of said West Carolina Avenue and the
east line of Kansas Street (80' R.O.W.) and being located in the east line of the Charles W. Shoffner
property recorded at Instrument No. 20023350; thence north 04 degrees 54 minutes 36 seconds
east with the east line of said property recorded at Instrument No. 20023350 a distance of 341.19
feet to a point in the sou th line of West Georgia Avenue (65' R.O.W.) a distance of 137.50 feet
east of the east line of Kansas Street; thence south 85 degrees 25 minutes 42 seconds east with the
south line of said West Georgia Avenue a distance of 22.41 feet to a point in the west line of the
Charles W. Shoffner property recorded at Instrument No. 20063264; thence south 04 degrees 44
minutes 05 seconds west with the west line of said property recorded at Instrument No. 20063264
and with the east line of Litty Place (12.5' Wide Public Alley) a distance of 161.63 feet to a point;
thence south 85 degrees 15 minutes 51 seconds east with the south line of said property recorded
at Instrument No. 20063264 and with the north line of a 20' Wide Public Alley a distance of 49.99
feet to a point; thence south 04 degrees 45 minutes 23 seconds west with the east end of said 20'
Wide Public Alley a distance of 20.00 feet to the north line of the Charles W. Shoffner property
recorded at Instrument No. 20021221; thence north 85 degrees 15 minutes 51 seconds west with
the north line of said property recorded at Instrument No. 20021221 and with the south line of said
20' wide alley a distance of 49.98 feet; thence south 04 degrees 44 minutes 05 seconds west with
the west line of said property recorded at Instrument No. 20021221 and with the east line of the
aforesaid Litty Place a distance of 159.61 feet to a point in the north line of the aforesaid West
Carolina Avenue; thence north 85 degrees 18 minutes 40 seconds west with the north line of said
West Carolina Avenue a distance of 23.46 feet to the Point of Beginning and containing 8,825
square feet or 0.203 acres of land.
WHEREAS, the City of Memphis has reviewed the recommendation of the Land Use
Control Board and the report and recommendation of the Division of Planning and Development
and desires to close the hereinabove described public right-of-way and it is deemed to be in the
best interest of the City of Memphis that said public right-of-way be vacated, and revert to the
abutting property owner(s); and
WHEREAS, a public hearing in relation thereto was held before the Memphis and Shelby
County Land Use Control Board on February 12, 2026, and said Board has submitted its findings
and recommendation to the Council of the City of Memphis subject to the following conditions:
1. The applicant shall comply with all City standards to the satis faction of the City
Engineer and City Fire Department.
2. Provide easements for existing sanity sewers, drainage facilities, and other utilities or
relocate at developer’s expense.
3. The applicant shall comply with all conditions of the closure within three years of the
conditional approval of the closure by the Council of the City of Memphis. Th e Land
Use Control Board may grant extensions to this date as Major Modifications as outlined
in Section 9.8.6 of the UDC.
NOW THEREFORE BE IT RESOLVED , by the Council of the City of Memphis that
the above described public right -of-way be and is hereby closed for public use, subject to the
aforementioned conditions.
BE IT FURTHER RESOLVED , that the Mayor is hereby authorized to execute all
Quitclaim Deed(s) to the owners of the properties abutting on the above described public right-of-
way, said Deeds not to be delivered until the conditions herein stated have been met by applicant.
BE IT FURTHER RESOLVED , that a copy of this resolution be sent to the Lawyers
Title Insurance Company, the Memphis Title Company, the Chicago Title Company, the Security
Title Company and the Shelby County Property Assessor's Office.
RIGHT-OF-WAY VACATION PLAT
ATTEST:
Cc: Division of Planning and Development – Land Use and Development Services
City Engineering – Land Development
City Real Estate
Staff Writer: Travian Smith E-mail: Travian.Smith@memphistn.gov
AGENDA ITEM: 2 L.U.C.B. MEETING: February 12, 2026
CASE NUMBER: SAC 2025-006
LOCATION: East of Kansas St., south of W Georgia Ave., north of W Carolina Ave., and west of
Florida St.
COUNCIL DISTRICT: District 6 and Super District 8
OWNER/APPLICANT: Charles Shoffner
REPRESENTATIVE: Matthew Hudgins
REQUEST: Close and vacate the public-right-of-way of a north-south public alley known as Litty
Place that has an east-west stub at it's midpoint heading eastward
EXISTING ZONING: Bluffview Residential District – (R-B)
CONCLUSIONS
1. The applicant is responsible for the cost and construction of the curb, gutter, and sidewalk across the
closure, as directed by the City Engineer. While Litty Place must remain open for fire access per the City
Fire Department, the applicant shall install a standard curb cut to the satisfaction of the City Engineer at
the applicant's expense.
2. Easements will be required to accommodate any existing public utilities, including electric, gas, water,
CATV, telephone, sewer, drainage, etc. or their relocation at the applicant’s expense
3. The closure of the subject right -of-way will not have any undue or substantial effect upon the existing
vehicular and pedestrian traffic flow of the surrounding area.
CONSISTENCY WITH MEMPHIS 3.0
The Memphis 3.0 General Plan is not applicable as it does not address the closure of alleys.
RECOMMENDATION:
Approval with conditions
Staff Report February 12, 2026
SAC 2025-006 Page 2
2
LOCATION MAP
Subject right-of-way located within the pink circle
SUBJECT RIGHT-OF-WAY
Staff Report February 12, 2026
SAC 2025-006 Page 3
3
PUBLIC NOTICE VICINITY MAP
Subject right-of-way highlighted in yellow
PUBLIC NOTICE DETAILS
In accordance with Sub-Section 9.3.4A of the Unified Development Code, a notice of public hearing is required
to be mailed. A total of 333 notices were mailed on December 18, 2025, see page 13 of this report for a copy of
said notice. Additionally, a total of two signs were posted, one at each end of the subject right-of-way, see page
14 of this report for a copy of the sign affidavit.
Staff Report February 12, 2026
SAC 2025-006 Page 4
4
AERIAL
Subject right-of-way outlined in yellow, imagery from 2021
Staff Report February 12, 2026
SAC 2025-006 Page 5
5
ZONING MAP
Subject right-of-way highlighted in yellow
Staff Report February 12, 2026
SAC 2025-006 Page 6
6
LAND USE MAP
Subject right-of-way indicated by a red star
Staff Report February 12, 2026
SAC 2025-006 Page 7
7
SITE PHOTOS
View of subject right-of-way from Carolina Avenue looking North
View of subject right-of-way from Georgia Avenue looking South
Staff Report February 12, 2026
SAC 2025-006 Page 8
8
RIGHT-OF-WAY VACATION PLAT
Staff Report February 12, 2026
SAC 2025-006 Page 9
9
LEGAL DESCRIPTION
Litty Place ROW Closure Description
Description of the City of Memphis property located in Block 88 of Ward 2 in Memphis, Shelby
County, Tennessee and being part of alleys in Block 26, Fort Pickering Subdivision (Unrecorded):
Beginning at a point in the north line of West Carolina Avenue (65' R.O.W.), said point being located
137.50 feet east of the intersection of the north line of said West Carolina Avenue and the east line of
Kansas Street (80' R.O.W.) and being located in the east line of the Charles W. Shoffner property
recorded at Instrument No. 20023350; thence north 04 degrees 54 minutes 36 seconds east with the
east line of said property recorded at Instrument No. 20023350 a distance of 341.19 feet to a point in
the south line of West Georgia Avenue (65' R.O.W.) a distance of 137.50 feet east of the east line of
Kansas Street; thence south 85 degrees 25 minutes 42 seconds east with the south line of said West
Georgia Avenue a distance of 22.41 feet to a point in the west line of the Charles W. Shoffner
property recorded at Instrument No. 20063264; thence south 04 degrees 44 minutes 05 seconds
west with the west line of said property recorded at Instrument No. 20063264 and with the east line of
Litty Place (12.5' Wide Public Alley) a distance of 161.63 feet to a point; thence south 85 degrees 15
minutes 51 seconds east with the south line of said property recorded at Instrument No. 20063264
and with the north line of a 20' Wide Public Alley a distance of 49.99 feet to a point; thence south 04
degrees 45 minutes 23 seconds west with the east end of said 20' Wide Public Alley a distance of
20.00 feet to the north line of the Charles W. Shoffner property recorded at Instrument No. 20021221;
thence north 85 degrees 15 minutes 51 seconds west with the north line of said property recorded at
Instrument No. 20021221 and with the south line of said 20' wide alley a distance of 49.98 feet;
thence south 04 degrees 44 minutes 05 seconds west with the west line of said property recorded at
Instrument No. 20021221 and with the east line of the aforesaid Litty Place a distance of 159.61 feet
to a point in the north line of the aforesaid West Carolina Avenue; thence north 85 degrees 18
minutes 40 seconds west with the north line of said West Carolina Avenue a distance of 23.46 feet to
the Point of Beginning and containing 8,825 square feet or 0.203 acres of land.
Staff Report February 12, 2026
SAC 2025-006 Page 10
10
CASE REVIEW
Request
The request is to close and vacate the public-right-of-way of a north-south public alley known as Litty Place that
has an east-west stub at its midpoint heading eastward.
Site Details
Address:
0 Litty Place
Area:
+/-8,800 square feet (.20 acres)
Description:
The subject right -of-way is a +/ -20-foot wide and +/ -341 long east -west public alley for a total area of 8,800
square feet within the block bounded by W Carolina and Georgia Avenue. The subject right-of-way is located in
between three parcels (002088 00001C, 002088 00002C, and 002088 00006) all of which are owned by Charles
Shoffner. The zoning of the area is Bluffview Residential District – (R-B) and is surrounded by a mixture of land
uses made up of industrial, residential single-family, and vacant lots.
Analysis
The applicant is responsible for the cost and construction of the curb, gutter, and sidewalk across the closure,
as directed by the City Engineer. While Litty Place must remain open for fire access per the City Fire Department,
the applicant shall install a standard curb cut to the satisfaction of the City Engineer at the applicant's expense.
Easements will be required to accommodate any existing public utilities, including electric, gas, water, CATV,
telephone, sewer, drainage, etc. or their relocation at the applicant’s expense
The closure of the subject right-of-way will not have any undue or substantial effect upon the existing vehicular
and pedestrian traffic flow of the surrounding area.
RECOMMENDATION
Staff recommends approval with conditions.
Conditions
1. The applicant shall comply with all City standards to the satisfaction of the City Engineer and City Fire
Department.
2. Provide easements for existing sanity sewers, drainage facilities, and other utilities or relocate at developer’s
expense.
3. The applicant shall comply with all conditions of the closure within three years of the conditional approval
of the closure by the Council of the City of Memphis. The Land Use Control Board may grant extensions to
this date as Major Modifications as outlined in Section 9.8.6 of the UDC.
Staff Report February 12, 2026
SAC 2025-006 Page 11
11
DEPARTMENTAL COMMENTS
The following comments were provided by agencies to which this application was referred:
City Engineer:
CASE 4: * SAC-25-006
NAME: ROW closure of approx. 8800 sq ft of Litty Place at Georgia Ave
Basin/Lot/CD: Fort Pickering, 1-N/ 0.26ac/6
1. Standard Public Improvement Contract or Right-Of-Way Permit as required in Section 5.5.5 of the Unified
Development Code.
Sewers:
2. There is an existing 8” sewer line in Alley. Dedicate minimum 15’ permanent sewer easement for the
sewer.
Street Closures:
3. Provide easements for existing sanitary sewers, drainage facilities and other utilities or relocate at
developer's expense.
4. City sanitary sewers/drainage facilities are located within the proposed closure area.
5. The applicant shall provide for the construction of curb, gutter and sidewalk across the closure as required
by the City Engineer. If the City Engineer approves access, the applicant shall construct a City Standard
curb cut across the closure, all to the satisfaction of the City Engineer, and at the applicant's expense. The
applicant shall enter into a Standard Improvement Contract or obtain a Right of Way permit from the City
Engineer to cover the above required construction work.
6. The applicant shall comply with all conditions of the closure within 3 years of the conditional approval of
the closure by the City Council.
7. Adequate queuing spaces in accordance with the current ordinance shall be provided between the street
right-of-way line and any proposed gate/guardhouse/card reader.
8. Adequate maneuvering room shall be provided between the right-of-way and the gate/guardhouse/card
reader for vehicles.
9. Required landscaping shall not be placed on sewer or drainage easements.
County Engineer: No comments received.
Staff Report February 12, 2026
SAC 2025-006 Page 12
12
City Fire Division:
1. Litty Place is required to be maintained for Fire Department access.
2. Where security gates are installed that affect required fire apparatus access roads, they shall comply
with section 503.6 (as amended).
3. All design and construction shall comply with the 2021 edition of the International Fire Code with local
amendments and referenced standards.
4. Fire apparatus access shall comply with section 503.
5. Where security gates are installed that affect required fire apparatus access roads, they shall comply
with section 503.6.
6. Fire protection water supplies (including fire hydrants) shall comply with section 507.
7. Where fire apparatus access roads or a water supply for fire protection are required to be installed, such
protection shall be installed and made serviceable prior to and during the time of construction except
when approved alternate methods of protection are provided.
8. IFC 510 In-building two-way emergency responder communication coverage shall be provided in all new
and existing buildings. Buildings and structures that cannot support the required level of coverage shall
be equipped with systems and components to enhance signals and achieve the required level of
communication coverage.
9. A detailed plans review will be conducted by the Memphis Fire Prevention Bureau upon receipt of
complete construction documents. Plans shall be submitted to the Shelby County Office of Code
Enforcement.
County Fire Division: No comments received.
City Real Estate: No comments received.
County Health Department: No comments received.
Shelby County Schools: No comments received.
Construction Code Enforcement: No comments received.
Memphis Light, Gas and Water: No comments received.
Office of Sustainability and Resilience: No comments received.
Office of Comprehensive Planning: No comments received.
Staff Report February 12, 2026
SAC 2025-006 Page 13
13
MAILED PUBLIC NOTICE
Staff Report February 12, 2026
SAC 2025-006 Page 14
14
SIGN AFFIDAVIT
+
Staff Report February 12, 2026
SAC 2025-006 Page 15
15
APPLICATION
Staff Report February 12, 2026
SAC 2025-006 Page 16
16
Staff Report February 12, 2026
SAC 2025-006 Page 17
17
Staff Report February 12, 2026
SAC 2025-006 Page 18
18
OWNER AFFIDAVIT
Staff Report February 12, 2026
SAC 2025-006 Page 19
19
LETTER OF INTENT
Staff Report February 12, 2026
SAC 2025-006 Page 20
20
LETTERS RECEIVED
No letters received at the time of completion of this report.
East Service Center: 6465 Mullins Station Rd; Memphis,
Tennessee 38134
Downtown Service Center: 125 N. Main Street;
Memphis, T
ennessee 38103
website: www.develop901.com
Memphis and Shelby County Division of
Planning and Development
Record Summary for Street and Alley Closure (Right of Way Vacation )
Record Detail Information
Record Type: Street and Alley Closure (Right of
Way Vacation)
Record Status: Pending
Opened Date: November 19, 2025
Record Number: SAC 2025-006
Record Name: Litty Place Alley Closure
Expiration Date:
Description of Work: Requesting the closure of an unused and neglected alley. Charles Shoffner (Applicant)
is the owner of all adjacent properties.
Parent Record Number:
Address:
LITTY PLACE, TN
Owner Information
Primary Owner Name
Owner Address Owner Phone
N
Data Fields
PREAPPLICA
TION MEETING
Name of DPD Planner Nabanita Nira
Date of Meeting 08/22/2025
Pre-application Meeting
Type Email
GENERAL INFORMATION
Name of Street where closure will begin W. Carolina Ave.
Name of Street where closure will end W. Georgia Ave.
What is the reason for the street closure? Unused / neglected Alley
What is the total area of the right-of-way being
closed?
8825
What is the overall length of the street closure? 341.19
Name of Street/Alley/ROW Litty Place
Page 1 of 3 SAC 2025-006
GENERAL INFORMATION
Is this application in response to a citation from
Construction Code Enforcement or Zoning
Letter?
No
If yes, please provide additional information -
Is this application a time extension? No
RELATED CASE INFORMATION
Previous Case Numbers -
GIS INFORMA
TION
Case Layer -
Central Business Improvement District No
Class -
Downtown Fire District No
Historic District -
Land Use -
Municipality -
Overlay/Special Purpose District -
Zoning -
State Route -
Lot -
Subdivision -
Planned Development District -
Wellhead Protection Overlay District No
County Commission District -
City Council District -
City Council Super District -
Data Tables
Property Owners
Property Address: 92 W. Carolina
Ave.
Property Owner Name: Charles W Shoffner
Mailing Address (if
different than property
address):
612 S. Main St. Memphis, TN 38103
Contact Information
Page 2 of 3 SAC 2025-006
CHARLES SHOFFNER
(901)483-2361
ADJACENT
PROPERTY
OWNER OF RECORD
Name
Address
Phone
Contact Type
CHARLES SHOFFNER
-
APPLICANT
Name
Address
Phone
Contact Type
LARRY
ASTIN
(901)683-9114
ARCHITECT / ENGINEER /
SUR
VEYOR
Name
Address
Phone
Contact Type
MATTHEW HUDGINS
(614)307-9730
REPRESENT
ATIVE
Name
Address
Phone
Contact Type
Fee Information
Date
AssessedBalanceStatusFeesQuantityFee ItemInvoice #
11
/19/20250.00INVOICED400.001Right of Way
Vacation/Closure Fee
1691619
11/19/20250.00INVOICED0.001Credit Card Use Fee (.026
x fee)
1691598
Total Fee Invoiced: $400.00 Total Balance: $0.00
Payment Information
Payment Amount Method of Payment
Fund T
ransfer$400.00
Page 3 of 3 SAC 2025-006
Litty Place ROW Closure Description
Description of the City of Memphis property located in Block 88 of Ward 2 in Memphis,
Shelby County, Tennessee and being part of alleys in Block 26, Fort Pickering
Subdivision (Unrecorded):
Beginning at a point in the north line of West Carolina Avenue (65' R.O.W.), said point
being located 137.50 feet east of the intersection of the north line of said West Carolina
Avenue and the east line of Kansas Street (80' R.O.W.) and being located in the east
line of the Charles W. Shoffner property recorded at Instrument No. 20023350; thence
north 04 degrees 54 minutes 36 seconds east with the east line of said property
recorded at Instrument No. 20023350 a distance of 341.19 feet to a point in the south
line of West Georgia Avenue (65' R.O.W.) a distance of 137.50 feet east of the east line
of Kansas Street; thence south 85 degrees 25 minutes 42 seconds east with the south
line of said West Georgia Avenue a distance of 22.41 feet to a point in the west line of
the Charles W. Shoffner property recorded at Instrument No. 20063264; thence south
04 degrees 44 minutes 05 seconds west with the west line of said property recorded at
Instrument No. 20063264 and with the east line of Litty Place (12.5' Wide Public Alley) a
distance of 161.63 feet to a point; thence south 85 degrees 15 minutes 51 seconds east
with the south line of said property recorded at Instrument No. 20063264 and with the
north line of a 20' Wide Public Alley a distance of 49.99 feet to a point; thence south 04
degrees 45 minutes 23 seconds west with the east end of said 20' Wide Public Alley a
distance of 20.00 feet to the north line of the Charles W. Shoffner property recorded at
Instrument No. 20021221; thence north 85 degrees 15 minutes 51 seconds west with
the north line of said property recorded at Instrument No. 20021221 and with the south
line of said 20' wide alley a distance of 49.98 feet; thence south 04 degrees 44 minutes
05 seconds west with the west line of said property recorded at Instrument No.
20021221 and with the east line of the aforesaid Litty Place a distance of 159.61 feet to
a point in the north line of the aforesaid West Carolina Avenue; thence north 85 degrees
18 minutes 40 seconds west with the north line of said West Carolina Avenue a distance
of 23.46 feet to the Point of Beginning and containing 8,825 square feet or 0.203 acres
of land.
19 November 2025
Memphis and Shelby County Division of Planning and Development
125 N. Main St. #477
Memphis, TN 38103
Division of Planning and Development,
Please see the attached documents for the requested alley closure at 0 Litty Place. The alley at Litty Place was has
been unused and informally abandoned for some time now. As the property owner of all adjacent parcels to the alley
in question, I am requesting that the right of way be formally vacated and deeded over to the parcels described in
the attached document to this application.
Sincerely,
Chuck Sho� ner
Realty Investment Group LLC
901.483.2361
LETTER OF INTENT
-----MEMPHIS AND== DIVISION OF PLANNING
SHELBY COUNTY.I AND DEVELOPMENT
City Hall - 125 N. Main Street, Suite 468 - Memphis, Tennessee 38103 - (901) 636-6619
Property Owner's Affidavit
Memphis and Shelby County Unified Development Code Section 12.3.1
OWNER: Includes the holder of legal title as well as holders of any equitable interest, such as trust beneficiaries,
contract purchasers, option holders, lessees under leases having an unexpired term of at least ten years, and the like.
Whenever a statement of ownership is required by the Memphis and Shelby County Unified Development Code, full
disclosure of all legal and equitable interest in the property is required. Memphis and Shelby County Unified
Development Code Section 12.3.1.
I, Charles Shoffner
(Print Name)
dnL ~~ate that I have read the definition of
(Sign Name) 7 •
"Owner" as outlined in the Memphis and Shelby County Unified Development Code Section 12.3.1 and hereby state
that (select applicable box):
~ I am the owner of record as shown on the current tax rolls of the county Assessor of Property; the mortgage
holder of record as shown in the mortgage records of the county Register of Deeds; purchaser under a land
contract; a mortgagee or vendee in possession; or I have a freehold or lesser estate in the premises
D I have charge, care or control of the premises as trustee, agent, executor, administrator, assignee, receiver,
guardian or lessee (and have included documentation with this affidavit)
of the property located at 92 W. Carolina, 78 W. Caroliona, 0 Georgia, 0 Carolina, 0 Carolina
and further identified by Assessor's Parcel Number 00208800001 c, 002088oooosc, 002088000002c, 00208800006,
for which an application is being made to the Division of Planning and Development. 00208800006
Subscribed and sworn to (or affirmed) before mj.~;.•~~'\ day of August in the year of 2025
§"l o~ •• ~
i f s~"1ss~~ \ \ My Commission Expires:
~ IDcuv i \ "'~~~"'"~~ j i re February 29, 2028 _JJ_ ~ •• ~\)'o\; _ •• ~ ~ ~
Signature of Notary Public \ ············•fW~~ My Commission Expires ~,,,, SHB.6'< ~,,-.: ~
~ :,,,,,,,,1111\\\\~~
co,,,M,ss~ 'C.,...
City Hall – 125 N. Main Street, Suite 468 – Memphis, Tennessee 38103 – (901) 636-6619
February 13, 2026
Charles Shoffner
Realty Investment Group LLC.
Sent via electronic mail to: chuckshoffner@gmail.com
Case Number: SAC 2026-006
LUCB Recommendation: Approval with conditions
Dear applicant,
On Thursday, February 12, 20 26, t he Memphis and Shelby County Land Use Control Board
recommended approval of your right-of-way vacation application to close and vacate the public-
right-of-way of a north-south public alley known as Litty Place that has an east -west stub at it ’s
midpoint heading eastward, subject to the following conditions:
1. The applicant shall comply with all City standards to the satisfaction of the City Engineer and
City Fire Department.
2. Provide easement s for e xisting sanity sewers , drainage facilities, and other utilities or
relocate at developer’s expense.
3. The applicant shall comply with all conditions of the closure wit hin three years of the
conditional approval of the closure by the Council of the City of Memphis. The L and Use
Control Board may grant extensions to this date as Major Modifications as outlined in Section
9.8.6 of the UDC.
The application will be forwarded, for final action, to the Council of the City of Memphis. The Council
will review your application in a committee meeting prior to vot ing on it in a public hearing. The
applicant or the applicant’s representative(s) shall be in attendance at all meetings and hearings.
It is the applicant’s responsibility to contact the City Council Records Office to determine when the
application is scheduled to be heard at co mmittee and in public session. The City Council Records
Office may be reached at (901) 636-6792.
If for some reason you choose to withdraw your application, a letter should be mailed to the Land
Use and Development Services Department of the Division of Planning and Development at the
address provided above or emailed to the address provided below.
Letter to Applicant
SAC 2026-006
Page 2 of 2
If you have questions regarding this matter, please feel free to contact me at (901) 636-6619 or via
email at Travian.Smith@memphistn.gov.
Respectfully,
Travian Smith
Planner I
Land Use and Development Services
Division of Planning and Development
Cc: Charles Shoffner
Cc: Matthew Hudgins
File
Memphis City Council
Summary Sheet
SUP 2026-001
RESOLUTION PURSUANT TO CHAPTER 9.6 OF THE MEMPHIS AND SHELBY COUNTY
UNIFIED DEVELOPMENT CODE APPROVING A SPECIAL USE PERMIT AT THE SUBJECT
PROPERTY LOCATED AT 3575 EMERALD STREET, KNOWN AS CASE NUMBER SUP 2026-001
• This item is a resolution with conditions for a special use permit to allow vehicle
sales; and
• The item may require future public improvement contracts.
1
LAND USE CONTROL BOARD RECOMMENDATION
At its regular meeting on Thursday, February 12, 2026, the Memphis and Shelby County Land Use Control
Board held a public hearing on the following application:
CASE NUMBER: SUP 2026-001
LOCATION: 3575 Emerald Street
COUNCIL DISTRICT(S): District 4 and Super District 8 – Positions 1, 2, and 3
OWNER/APPLICANT: Dennis Small - Small’s Automotive LLC
REPRESENTATIVE: Brian Bacchus – Bacchus Urban Design Group (BUD)
REQUEST: To allow a commercial surface parking lot for a period not to exceed
fifteen (15) years
EXISTING ZONING: Commercial Mixed Use—1 (CMU-1)
AREA: +/-22,172 square feet
The following spoke in support: None
The following spoke in opposition: None
The Land Use Control Board reviewed the application and the staff report . A motion was made and
seconded to recommend approval with conditions.
The motion passed by a vote of 9-0 on the consent agenda.
Respectfully,
Cc: Committee Members
File
2
SUP 2026-001
CONDITIONS
1. Vehicle repair and used tire sales are prohibited.
2. Outdoor display and sales shall be limited to the requirements of UDC Sub-Section 4.8.4A.
3. All street frontages must have streetscape installed or an equivalent alternative approved by the
Division of Planning and Development.
4. The dumpster location and screening shall meet the requirements of UDC Sub-Section 4.6.8B.
5. All parking and vehicle use areas shall be surfaced and all parking spaces shall be painted with striping.
6. The applicant shall submit a final site plan and landscape plan subject to administrative review and
approval by the Division of Planning and Development
3
COCEPT PLAN
RESOLUTION PURSUANT TO CHAPTER 9.6 OF THE MEMPHIS AND SHELBY COUNTY
UNIFIED DEVELOPMENT CODE APPROVING A SPECIAL USE PERMIT AT THE SUBJECT
PROPERTY LOCATED AT 3575 EMERALD STREET, KNOWN AS CASE NUMBER SUP 2026-
001
WHEREAS, Chapter 9.6 of the Memphis and Shelby County Unified Development Code, being a
section of the Joint Ordinance Resolution No. 5367, dated August 10, 2010, authorizes the Council of the
City of Memphis to grant a special use permit for certain stated purposes in the various zoning districts;
and
WHEREAS, Dennis Small - Small’s Automotive LLC filed an application with the Memphis and
Shelby County Division of Planning and Development to allow vehicle sales; and
WHEREAS, the Division of Planning and Development has received and reviewed the application
in accordance with procedures, objectives, and standards for special use permits as set forth in Chapter 9.6
with regard to the proposed development's impacts upon surrounding propertie s, availability of public
facilities, both external and internal circulation, land use compatibility, and that the design and amenities
are consistent with the public interest; and has submitted its findings and recommendation concerning the
above considerations to the Land Use Control Board; and
WHEREAS, a public hearing in relation thereto was held before the Memphis and Shelby County
Land Use Control Board on February 12, 20 26, and said Board has submitted its findings and
recommendation concerning the above considerations to the Council of the City of Memphis; and
WHEREAS, the Council of the City of Memphis has reviewed the aforementioned application
pursuant to Tennessee Code Annotated Section 13 -4-202(B)(2)(B)(iii) and has determined that said
development is consistent with the Memphis 3.0 General Plan; and
WHEREAS, the Council of the City of Memphis has reviewed the recommendation of the Land
Use Control Board and the report and recommendation of the Division of Planning and Development and
has determined that said development meets the objectives, standards and criteria for a special use permit,
and said development is consistent with the public interests.
NOW, THEREFORE, BE IT RESOLVED, BY THE COUNCIL OF THE CITY OF
MEMPHIS, that, pursuant to Chapter 9.6 of the Memphis and Shelby County Unified Development Code,
a special use permit is hereby granted for the request use in accordance with the attached conditions.
BE IT FURTHER RESOLVED , that this permit merely authorizes the filing of applications to
acquire a Certificate of Use and Occupancy, or a Building Permit, and other required permits and approvals,
provided that no such Certificate of Use and Occupancy shall be granted until all conditions imposed by
the Council of the City of Memphis have been met.
BE IT FURTHER RESOLVED , that this Resolution take effect from and after the date it shall
have been passed by this Council of the City of Memphis, and become effective as otherwise provided by
law, and thereafter shall be treated as in full force and effect by virtue of passage thereof by the Council of
the City of Memphis, the public welfare requiring same.
CONDITIONS
1. Vehicle repair and used tire sales are prohibited.
2. Outdoor display and sales shall be limited to the requirements of UDC Sub-Section 4.8.4A.
3. All street frontages must have streetscape installed or an equivalent alternative approved by the Division
of Planning and Development.
4. The dumpster location and screening shall meet the requirements of UDC Sub-Section 4.6.8B.
5. All parking and vehicle use areas shall be surfaced and all parking spaces shall be painted with striping.
6. The applicant shall submit a final site plan and landscape plan subject to administrative review and
approval by the Division of Planning and Development.
CONCEPT PLAN
ATTEST:
CC: Division of Planning and Development
– Land Use and Development Services
– Office of Construction Enforcement
Staff Writer: Mahsan Ostadnia E-mail: mahsan.ostadnia@memphistn.gov
AGENDA ITEM: 11 L.U.C.B. MEETING: February 12, 2026
CASE NUMBER: SUP 2026-001
LOCATION: 3575 Emerald Street
COUNCIL DISTRICT: District 4 and Super District 8 – Positions 1, 2, and 3
OWNER/APPLICANT: Dennis Small - Small’s Automotive LLC
REPRESENTATIVE: Brian Bacchus – Bacchus Urban Design Group (BUD)
REQUEST: Special use permit to allow vehicle sales
EXISTING ZONING: Commercial Mixed Use—1 (CMU-1)
CONCLUSIONS
1. The applicant is requesting a Special Use Permit for motor vehicle sales, limited to used vehicles at 3575
Emerald Street, located on Lots 6 and 7 of Emerald Square Subdivision and zoned CMU-1. The site includes
an existing 2,800 -square-foot building const ructed in 1977 and is surrounded by mixed commercial,
institutional, office, and residential uses.
2. The property previously functioned as a vehicle wash and automotive service facility, a permitted use in
the CMU-1 district. The proposal retains service use and introduces used vehicle sales, subject to approval
of a Special Use Permit . The submitted vehicle display concept primarily arranged along the north, west,
and south portions of the property. The layout maintains dedicated access to the service and carwash bays
and depicts one -way internal circulation with defined maneuvering ar eas to accommodate both vehicle
display and service activities.
3. The subject property includes two adjacent lots, each approximately 185 feet wide by 60 feet deep,
resulting in a combined site depth of approximately 120 feet. Emerald Street is identified as a 60-foot right-
of-way, and access is provided through a gated entrance with paved apron frontage. A 10 -foot drainage
easement is located along the southern property line. Additional site features shown include existing
fencing, concrete and asphalt paving, and utility infrastructure serving the property.
4. The granting of this special use permit will not cause substantial detriment to the public good, nor will it
substantially impair the intent and purpose of an adopted plan or the Unified Development Code (UDC),
nor will it be injurious to the neighborhood or the general welfare, and it will be in harmony with the
purpose and intent of the UDC.
CONSISTENCY WITH MEMPHIS 3.0
This proposal is consistent with the Memphis 3.0 General Plan per the land use decision criteria. See further
analysis on pages 19-21 of this report.
RECOMMENDATION:
Approval with conditions
Staff Report February 12, 2026
SUP 2026-001 Page 2
2
LOCATION MAP
Subject property located within the pink circle.
SUBJECT PROPERTY
Staff Report February 12, 2026
SUP 2026-001 Page 3
3
PUBLIC NOTICE VICINITY MAP
Subject property highlighted in yellow.
PUBLIC NOTICE DETAILS
In accordance with Sub-Section 9.3.4A of the Unified Development Code, a notice of public hearing is required
to be mailed and signage posted. A total of 97 notices were mailed on January 1 3, 2026, see page 22 of this
report for a copy of said notice . Additionally, one sign was posted at the subject property, see page s 23-24 of
this report for a copy of the sign affidavit.
NEIGHBORHOOD MEETING
The meeting was held at 6:00 to 7:00 PM on Thursday, February 5, 2026, at 3575 Emerald Street, Memphis, TN
38115. See pages 25-26 of this report for a copy of the neighborhood meeting summary.
Staff Report February 12, 2026
SUP 2026-001 Page 4
4
EMERALD SQUARE SUBDIVISION (1976) (PLAT BOOK 65 PAGE 5)
Subject property highlighted in yellow.
Staff Report February 12, 2026
SUP 2026-001 Page 5
5
AERIAL
Subject property outlined in yellow.
Staff Report February 12, 2026
SUP 2026-001 Page 6
6
ZONING MAP
Subject property highlighted in yellow.
Staff Report February 12, 2026
SUP 2026-001 Page 7
7
LAND USE MAP
Subject property indicated by a yellow star.
Staff Report February 12, 2026
SUP 2026-001 Page 8
8
SITE PHOTOS
View of subject property from Emerald Street (front).
View of subject property from Emerald Street (west).
View of subject property from above.
Staff Report February 12, 2026
SUP 2026-001 Page 9
9
View of subject property from above.
View of subject property from above.
Staff Report February 12, 2026
SUP 2026-001 Page 10
10
CONCEPT PLAN
Staff Report February 12, 2026
SUP 2026-001 Page 11
11
SITE PLAN
Staff Report February 12, 2026
SUP 2026-001 Page 12
12
SITE PLAN – MAGNIFIED
Staff Report February 12, 2026
SUP 2026-001 Page 13
13
CASE REVIEW
Request
The request is a special use permit to allow vehicle sales.
Approval Criteria
Staff agrees the approval criteria in regard to special use permits as set out in Section 9. 6.9 of the Unified
Development Code are met.
9.6.9 Approval Criteria
No special use permit or planned development shall be approved unless the following findings are made
concerning the application:
9.6.9A The project will not have a substantial or undue adverse effect upon adjacent property, the
character of the neighborhood, traffic conditions, parking, utility facilities and other matters
affecting the public health, safety, and general welfare.
9.6.9B The project will be constructed, arranged and operated so as to be compatible with the
immediate vicinity and not interfere with the development and use of adjacent property in
accordance with the applicable district regulations.
9.6.9C The project will be served adequately by essential public facilities and services such as streets,
parking, drainage, refuse disposal, fire protection and emergency services, water and sewers; or
that the applicant will provide adequately for such services.
9.6.9D The project will not result in the destruction, loss or damage of any feature determined by the
governing bodies to be of significant natural, scenic or historic importance.
9.6.9E The project complies with all additional standards imposed on it by any particular provisions
authorizing such use.
9.6.9F The request will not adversely affect any plans to be considered (see Chapter 1.9), or violate the
character of existing standards for development of the adjacent properties.
9.6.9G The governing bodies may impose conditions to minimize adverse effects on the neighborhood
or on public facilities, and to ensure compatibility of the proposed development with surrounding
properties, uses, and the purpose and intent of this development code.
9.6.9H Any decision to deny a special use permit request to place, construct, or modify personal wireless
service facilities shall be in writing and supported by substantial evidence contained in a written
record, per the Telecommunications Act of 1996, 47 USC 3 32(c)(7)(B)(iii). The review body may
not take into account any environmental or health concerns.
Site Details
Address:
3575 Emerald Street
Parcel ID:
074102 00092
Area:
+/-22,172 square feet
Staff Report February 12, 2026
SUP 2026-001 Page 14
14
Description:
The subject property is known as Lot 6 and 7 of Emerald Square Subdivision a zoning of Commercial Mixed-Use-
1 (CMU-1). Per the Assessor’s website, the principal structure on the site was built in 1977 with a ground floor
area of 2,800 square feet and the surrounding land uses are a mixture of commercial, institutional, office, and
single-family lots. Additionally, this lot has one street frontage.
Site Plan Review
The subject property includes Lots 6 and 7 of Emerald Square Subdivision, located along Emerald Street. Each
lot is approximately 185 feet wide by 60 feet deep, creating a combined site depth of roughly 120 feet. Emerald
Street is identified as a 60 -foot r ight-of-way, and the site is served by paved apron access along the street
frontage. A 10-foot drainage easement is located along the southern property line. The site is developed with
an existing block building ( #3575) and associated carwash bays, with co ncrete apron areas surrounding the
structures for vehicular circulation and service access.
Vehicular access to the site is provided from Emerald Street through a gated entrance, with paved internal
circulation throughout the property. The existing building extends approximately 185 feet in width, with service
and carwash bays oriented toward the interior apron area. The submitted concept plan depicts one-way internal
circulation and clearly defined maneuvering areas designed to accommodate vehicle service and display
activities while avoiding backing movements onto Emerald Street.
The vehicle sales display concept plan illustrates approximately 25 on -site vehicle display spaces distributed
along the perimeter and interior paved apron areas of Lots 6 and 7. Display spaces are primarily located along
the north, west, and south edges o f the site. The plan also maintains dedicated service access to the existing
building and carwash bays.
Additional site features shown include concrete and asphalt paving, fencing along portions of the property
boundary, utility elements such as water meters, sewer manholes, and power poles, and apron areas along the
frontage.
Prior to final site plan approval, the applicant shall revise the parking layout to resolve the overlap of vehicle
display within parking spaces 21/22 and 18/19. All parking spaces, drive aisles, and maneuvering areas shall be
clearly dimensioned and shown to scale to demonstrate compliance with the parking design standards of UDC
Sub-Section 4.5.5A. The final site plan shall also include additional landscaping in the area identified on the
concept plan to enhance site appearance and buffering.
Analysis
The applicant is requesting a Special Use Permit for motor vehicle sales, limited to used vehicles at 3575 Emerald
Street, located on Lots 6 and 7 of Emerald Square Subdivision and zoned CMU -1. The site includes an existing
2,800-square-foot building const ructed in 1977 and is surrounded by mixed commercial, institutional, office,
and residential uses.
The property previously functioned as a vehicle wash and automotive service facility, a permitted use in the
CMU-1 district. The proposal retains service use and introduces used vehicle sales, subject to approval of a
Special Use Permit. The submitted vehicle display concept primarily arranged along the north, west, and south
portions of the property. The layout maintains dedicated access to the service and carwash bays and depicts
one-way internal circulation with defined maneuvering areas to accommodate both vehicle display and service
Staff Report February 12, 2026
SUP 2026-001 Page 15
15
activities.
The subject property includes two adjacent lots, each approximately 185 feet wide by 60 feet deep, resulting in
a combined site depth of approximately 120 feet. Emerald Street is identified as a 60 -foot right-of-way, and
access is provided through a gated entrance with paved apron frontage. A 10-foot drainage easement is located
along the southern property line. Additional site features shown include existing fencing, concrete and asphalt
paving, and utility infrastructure serving the property.
The granting of this special use permit will not cause substantial detriment to the public good, nor will it
substantially impair the intent and purpose of an adopted plan or the Unified Development Code (UDC), nor will
it be injurious to the neighborhood or the general welfare, and it will be in harmony with the purpose and intent
of the UDC.
RECOMMENDATION
Staff recommends approval with conditions.
Conditions
1. Vehicle repair and used tire sales are prohibited.
2. Outdoor display and sales shall be limited to the requirements of UDC Sub-Section 4.8.4A.
3. All street frontages must have streetscape installed or an equivalent alternative approved by the Division of
Planning and Development.
4. The dumpster location and screening shall meet the requirements of UDC Sub-Section 4.6.8B.
5. All parking and vehicle use areas shall be surfaced and all parking spaces shall be painted with striping.
6. The applicant shall submit a final site plan and landscape plan subject to administrative review and approval
by the Division of Planning and Development
Staff Report February 12, 2026
SUP 2026-001 Page 16
16
DEPARTMENTAL COMMENTS
The following comments were provided by agencies to which this application was referred:
City Engineer: See page 17.
County Engineer: No comments received.
City Fire Division: See page 18.
County Fire Division: No comments received.
City Real Estate: No comments received.
County Health Department: No comments received.
Shelby County Schools: No comments received.
Construction Code Enforcement: No comments received.
Memphis Light, Gas and Water: No comments received.
Office of Sustainability and Resilience: No comments received.
Office of Comprehensive Planning: See pages 19-21.
Staff Report February 12, 2026
SUP 2026-001 Page 17
17
City Engineer:
1. Standard Public Improvement Contract or Right -Of-Way Permit as required in Section 5.5.5 of the Unified
Development Code.
Sewers:
2. City sanitary sewer capacity is available to serve this development.
Roads:
3. The Developer shall be responsible for the repair and/or replacement of all existing curb and gutter along
the frontage of this site as necessary.
4. All existing sidewalks and curb openings along the frontage of this site shall be inspected for ADA
compliance. The developer shall be responsible for any reconstruction or repair necessary to meet City
standards.
Traffic Control Provisions:
5. The developer shall provide a traffic control plan to the city engineer that shows the phasing for each street
frontage during demolition and construction of curb gutter and sidewalk. Upon completion of sidewalk and
curb and gutter improvements, a minimum 5 foot wide pedestrian pathway shall be provided throughout
the remainder of the project. In the event that the existing right of way width does not allow for a 5 foot
clear pedestrian path, an exception may be considered.
6. Any closure of the right of way shall be time limited to the active demolition and construction of sidewalks
and curb and gutter. Continuous unwarranted closure of the right of way shall not be allowed for the
duration of the project. The developer shall provide on the traffic control plan, the time needed per phase
to complete that portion of the work. Time limits will begin on the day of closure and will be monitored by
the Engineering construction inspectors on the job.
7. The developer’s engineer shall submit a Trip Generation Report that documents the proposed land use,
scope and anticipated traffic demand associated with the proposed development. A detailed Traffic Impact
Study will be required when the accepted Trip Generation Report indicates that the number for projected
trips meets or exceeds the criteria listed in Section 210 -Traffic Impact Policy for Land Development of the
City of Memphis Division of Engineering Design and Policy Review Manual. Any required Traffic Impact Study
will need to be formally approved by the City of Memphis, Traffic Engineering Department.
Curb Cuts/Access:
8. The City Engineer shall approve the design, number, and location of curb cuts.
9. Any existing nonconforming curb cuts shall be modified to meet current City Standards or closed with curb,
gutter, and sidewalk.
Staff Report February 12, 2026
SUP 2026-001 Page 18
18
City Fire Division:
1. All design and construction shall comply with the 2021 edition of the International Fire Code with local
amendments and referenced standards.
2. Fire apparatus access shall comply with section 503.
3. Where security gates are installed that affect required fire apparatus access roads, they shall comply
with section 503.6.
4. Fire protection water supplies (including fire hydrants) shall comply with section 507.
5. Where fire apparatus access roads or a water supply for fire protection are required to be installed,
such protection shall be installed and made serviceable prior to and during the time of construction
except when approved alternate methods of protection are provided.
6. IFC 510 In-building two-way emergency responder communication coverage shall be provided in all
new and existing buildings. Buildings and structures that cannot support the required level of coverage
shall be equipped with systems and components to enhance signals and achieve the required level of
communication coverage.
7. A detailed plans review will be conducted by the Memphis Fire Prevention Bureau upon receipt of
complete construction documents. Plans shall be submitted to the Shelby County Office of Code
Enforcement.
Staff Report February 12, 2026
SUP 2026-001 Page 19
19
Office of Comprehensive Planning
This summary is being produced in response to the following application to support the Land Use and
Development Services Department in their recommendation: SUP 2026-001 Oakhaven/Parkway Village
Site Address/Location: 3575 Emerald St
Overlay District/Historic District/Flood Zone: Site overlaps with a flood zone
Future Land Use Designation: Low Intensity Commercial and Services (CSL)
Street Type: Avenue
The applicant is requesting a Special Use Permit to allow office/showroom for motor vehicle sales.
The following information about the land use designation can be found on pages 76 – 122:
1. Future Land Use Planning Map
Red polygon indicates the application site on the Future Land Use Map.
2. Land Use Description/Intent
Low Intensity Commercial and Service (CSL) areas are
typically not associated with anchors. These areas may
include neighborhood supporting commercial uses such
as retail sales and services, offices, restaurants, funeral
services, small-scale recreation, social service institutions,
and occasional upper-story residential. Graphic portrayal
of CSL is to the right.
Staff Report February 12, 2026
SUP 2026-001 Page 20
20
“CSL” Form & Location Characteristics
Commercial and services uses, 1-4 stories height
“CSL” Zoning Notes
Generally compatible with the following zone districts: CMU-1 without frontage requirements, OG, SDBP in
accordance with Form and characteristics listed above.
Existing, Adjacent Land Use and Zoning
Existing Land Use and Zoning: Commercial; CMU-1
Adjacent Land Use and Zoning: Commercial, Office, Institutional; CMU-1, R-6
Overall Compatibility: This requested use is compatible with the existing land use description/intent, form &
location characteristics, zoning notes. It is consistent with the existing, adjacent land uses such as a gas station
and an auto parts & car repair shop.
Degree of Change Map
Red polygon denotes the proposed site on the Degree of Change Map. There is no Degree of Change.
3. Degree of Change Description
N/A
4. Objectives/Actions Consistent with Goal 1, Complete, Cohesive, Communities
N/A
5. Pertinent Sections of Memphis 3.0 that Address Land Use Recommendations
Staff Report February 12, 2026
SUP 2026-001 Page 21
21
Consistency Analysis Summary
The applicant is requesting a Special Use Permit to allow office/showroom for motor vehicle sales.
This requested use is not compatible with the existing land use description/intent, form & location
characteristics, zoning notes. It is consistent with the existing, adjacent land uses such as a gas station and an
auto parts & car repair shop.
Based on the information provided, the proposal is CONSISTENT with the Memphis 3.0 Comprehensive Plan.
Staff Report February 12, 2026
SUP 2026-001 Page 22
22
MAILED PUBLIC NOTICE
Staff Report February 12, 2026
SUP 2026-001 Page 23
23
SIGN AFFIDAVIT
Staff Report February 12, 2026
SUP 2026-001 Page 24
24
Staff Report February 12, 2026
SUP 2026-001 Page 25
25
NIEGHBORHOOD MEETING SUMMARY
Staff Report February 12, 2026
SUP 2026-001 Page 26
26
Staff Report February 12, 2026
SUP 2026-001 Page 27
27
APPLICATION
Staff Report February 12, 2026
SUP 2026-001 Page 28
28
Staff Report February 12, 2026
SUP 2026-001 Page 29
29
Staff Report February 12, 2026
SUP 2026-001 Page 30
30
Staff Report February 12, 2026
SUP 2026-001 Page 31
31
OWNER AFFIDAVIT
Staff Report February 12, 2026
SUP 2026-001 Page 32
32
LETTER OF INTENT
Staff Report February 12, 2026
SUP 2026-001 Page 33
33
Staff Report February 12, 2026
SUP 2026-001 Page 34
34
Staff Report February 12, 2026
SUP 2026-001 Page 35
35
LETTERS RECEIVED
No letters received at the time of completion of this report.
East Service Center: 6465 Mullins Station Rd; Memphis,
Tennessee
38134
Downtown Service Center: 125 N. Main Street;
Memphis, T
ennessee 38103
website: www.develop901.com
Memphis and Shelby County Division of
Planning and Development
Record Summary for Special Use Permit
Record Detail Information
Record T
ype: Special Use Permit Record Status: Assignment
Opened Date:
January 2, 2026
Record Number: SUP 2026-001
Record Name: Small's Automotive, LLC
Expiration Date:
Description of Work: Special Use Permit to allow office/showroom for motor vehicle sales, service and
repair of vehicles
Parent Record Number:
Address:
3575 EMERALD ST, MEMPHIS, Tennessee 381
15
Owner Information
Primary Owner Name
Owner Address Owner Phone
Y L
& A AUTOMOTIVE LLC
2635 FRIDDELL CV, MEMPHIS, TN 38133 9015305441
Parcel Information
074102 00092
Data Fields
PREAPPLICA
TION MEETING
Name of DPD Planner Mahsan Ostadnia
Date of Meeting 12/18/2025
Pre-application Meeting
Type In Person
GENERAL PROJECT INFORMATION
Application Type New Special Use Permit (SUP)
List any relevant former Docket / Case
Number(s) related to previous applications on
this site
-
Is this application in response to a citation, stop No
Page 1 of 4 SUP 2026-001
GENERAL PROJECT INFORMATION
work order, or zoning letter
If yes, please provide a copy of the citation, stop
work order, and/or zoning letter along with any
other relevant information
-
APPROVAL CRITERIA
A) The project will not have a substantial or
undue adverse ef
fect upon adjacent property, the
character of the neighborhood, traffic conditions,
parking, utility facilities and other matters
affecting the public health, safety, and general
welfare
The adjacent land uses to the south for a small retail
center and convenient store with gasoline pumps
directly facing Winchester Road, including the auto
repair shop directly adjacent to the north will not be
affected by this proposal. Nor will the charter school
directly across the street from the subject property
and the existing auto wheel repair shop and cable
contracting facility be affected by the proposed use.
The property, including adjacent property to the north
in single ownership is totally enclosed with a
wrought-iron decorative fence for security and safety
inside and outside the property.
B) The project will be constructed, arranged and
operated so as to be compatible with the
immediate vicinity and not interfere with the
development and use of adjacent property in
accordance with the applicable district
regulations
The subject property, including site improvements
will be utilized and maintained in its current
conditions and no new construction is proposed in
this application. The proposal will be arranged and
operated in a manner to be compatible with
surrounding properties and will not interfere with any
future development and use of any adjacent property
in accordance with the CMU-1 District regulations.
UDC Sub-Section 9.6.9C The subject property is currently served by essential
public facilities by a public street, adequate access,
parking, circulation, refuse, fire and emergency
services, including electricity, natural gas, water,
adequate drainage, and sewer services are
provided on the property.
UDC Sub-Section 9.6.9D The subject property does not have any history of
being or possessing any significant natural, scenic
or historic importance that will result in the
destruction, loss or damage of any feature(s)
determined by any governing body.
UDC Sub-Section 9.6.9E The proposed project, if approved will comply with
the Use Standard provisions of Sub-Section 2.6.3.P
of the UDC for motor vehicle sales, service and
repair, including outdoor display and sales
requirements of Sub-Section 4.8.4A as allowed by
Special Use Permit.
Page 2 of 4 SUP 2026-001
APPROVAL CRITERIA
UDC Sub-Section 9.6.9F Memphis 3.0’s Low Intensity Commercial Services
(often aligned with auto-oriented corridors or
small-scale service commercial areas typically
supports:
• Small format retail and service use
• Low impact commercial activity
•
Uses that do not generate heavy traffic, noise, or
outdoor storage
• Development that is compatible with adjacent
residential or neighborhood scale commercial
properties
Motor vehicle sales can fit into commercial service
areas by Special Use Permit (SUP).
The intent is to activate an existing commercial
property with a low-impact use that aligns with the
corridor’s character and the Memphis 3.0 vision for
reinvestment in established commercial areas. The
proposed use fits within this context and does not
introduce a new or incompatible development
pattern. The scale of the operation is modest, and
the applicant is committed to meeting the proposed
Sit Plan Conditions.
•Existing Context:
The surrounding area already contains commercial
and light industrial uses. Motor vehicle sales are
consistent with the corridor’s established
development pattern.
• Low Intensity Operations:
The applicant proposes a small format sales
operation with limited inventory, no outdoor repair
activity, and no high-volume traffic generation.
GIS INFORMATION
Case Layer -
Central Business Improvement District No
Class C
Downtown Fire District No
Historic District -
Land Use COMMERCIAL
Municipality MEMPHIS
Overlay/Special Purpose District -
Zoning CMU-1
State Route -
Lot 6 & 7
Subdivision EMERALD SQUARE
Planned Development District -
Wellhead Protection Overlay District Yes
County Commission District -
Page 3 of 4 SUP 2026-001
GIS INFORMATION
City Council District -
City Council Super District -
Contact Information
BRIAN S. BACCHUS
(901)785-5988
APPLICANT
Name
Address
Phone
Contact Type
BRIAN BACCHUS
(901)785-5988
REPRESENT
ATIVE
Name
Address
Phone
Contact Type
Fee Information
Date AssessedBalanceStatusFeesQuantityFee ItemInvoice #
01/02/20260.00INVOICED500.001Special Use Permit Fee -
5 acres or less (Base Fee)
1699195
01/02/20260.00INVOICED13.001Credit Card Use Fee (.026
x fee)
1699195
Total Fee Invoiced
: $513.00 Total Balance: $0.00
Payment Information
Payment
Amount Method of Payment
Credit Card$513.00
Page 4 of 4 SUP 2026-001
BUD Group
'From the Property Line to the Parapet'
LETTER OF INTENT
BUD GROUP
(Bacchus Urban Design Group)
Brian S. Bacchus, Principal Consultant
5320 White Diamond Street
Memphis, TN 38109
Date: December 31, 2025
To: Land Use Control Board
Secretary, Chairman, Vice-Chairman and Board Members
Re: 3575 Emerald Street
Special Use Permit: Motor Vehicle Sales and Service
Greetings Mr. Secretary,
On behalf of the property owner, L & A Automotive, LLC and Mr. Dennis Small of S mall’s
Automotive, LLC, we are requesting a Special Use Permit for the above-mentioned property to allow
motor vehicle sales and service on two (2) lots in Emerald Square Subdivision totaling 0.50 acres or
22, 170 sq. ft. in area. The lots are in Commercial Mixed Use (CMU-1) District zoning at the west side
of Emera ld Street , +/-160.62 feet north of Winche ster Road over one-quarter (¼) mile from
Williamsburg Colony and Bishop ’s Bri dge neighborhoods in the southeast portion of the City of
Memphis. The site was a former vehicle wash and automotive service facility permitted by right in
the CMU-1 District.
The applicant, Mr. Small is proposing the principal use of the property for motor vehicle sales
and services as outlined in the proposed enclosed Site Plan Conditions and agreed upon by the
applicant with limited retail sales of automotive products such as lubrication, motor oil and oil
filters, auto wax, auto cloths, and auto cleaning products. The use of space within the main building
will include reception desk, sales counter, sales offices, break rooms, bathrooms, storage areas
and a mini-indoor showroom with outdoor auto display bays attached to the main building.
The proposed land use for motor vehicle service is permitted by right in the CMU-1 District, but
the request for motor vehicle sales is permitted by Special Use Permit. The motor vehicle sales will
be located on the balance of the property with designated s ales and display area s for customer
service for a total displa y of ve hicles for sale and display at any one time will be a maximum of
twenty-five (25) vehicles.
BUD Group
'From the Property Line to the Parapet'
The required parking spaces for motor vehicle sales and service are a ratio of 1:500 sq. ft. of
indoor floor area plus a ratio of 1:10,000 sq. ft. for outdoor lot area for a total of seven (7) required
parking spaces, including one (1) handicap space. Parking will be provided for the main building and
outdoor motor vehicle display area to meet required parking for all proposed indoor and outdoor
uses of the property as illustrated on the site plan.
This facility is intended to serve the southeastern portion of the City of Memphis, focusing on
residential neighborhoods such as Williamsburg Colony and Bishop’s Bridge, as well as the
surrounding commercial establishments, including the Mendenhall Square Retail Shopping Center.
The market comprises individuals and families seeking reliable pre-owned vehicles and automotive
services, along with local businesses in need of fleet maintenance and vehicle care. By offering both
sales and service, the site aims to meet the diverse tran sportation needs of a sustainable market
area.
The applicant, Small’s Automotive, LLC prides itself in being the Number #1 source for buying
quality pre -owned vehicles in the marketplace with extensive relationships in the dealer’s
community, which allows them to purchase a wide variety of lease returns and new car trades at
exceptional values. This model enables them to pass along huge savings on the highest quality
vehicles of choice in this service market.
In summary, the request for approval of a Special Use Permit with conditions to allow motor
vehicle sales and service at this location is articulated as follows: motor vehicle sales display area
for up to twenty-five (25) vehicles which will meet required parking standards with seven (7) spaces,
including one (1) space. The application also details compliance with zoning and proposed site plan
conditions. On behalf of the applicant , we respectfully request a favorable recommendation for a
Special Use Permit to allow the propos ed land use within this market area in the s outheastern
portion of the City of Memphis.
Sincerely,
Brian S. Bacchus, Principal Consultant
BUD Group
(901) 832-7203
BacchusUrbanDesignGroup@Outlook.com
cc: Mr. Dennis Small, Small’s Automotive, LLC
Chairman, Vice Chairman and Board Members
BUD Group
‘From the Property Line to the Parapet’
S.U.P. 2026-???
3575 Emerald Street
Site Plan Conditions (Proposed)
D/B/A: Small’s Automotive, LLC
1. The special permit to allow office/showroom for motor vehicle sales, service and
repair of vehicles, including twenty-four (24) hour roadside assistance and short-
term vehicle storage.
2. The applicable Use Standard provisions of Sub-Section 2.6.3P of the UDC for
motor vehicle sales, service, and repair shall be applied to the subject property.
3. The outdoor display and sales shall be limited to the requirements of UDC Sub -
Section 4.8.4A, but to include outdoor sales, display, limited general outdoor
storage of motor vehicles and merchandise.
4. The existing wrought -iron fencing shall be preserved and maintained. Any new
fencing and gating shall m atch existing fence material. No razor wire or barbed
wire shall be permitted.
5. All required parking and vehicle display areas shall maintain the surface parking
and all parking spaces shall be delineated with striped painted lines.
6. Detached and attached signs shall be as permitted and regulated in the
Commercial Mixed Use (CMU-1) District.
S.U.P. 2026-???
Site Plan Conditions
Shelby County ITS / ReGIS 160 North Main, Suite 1000, Memphis,
TN 38103 email: ReGIS@shelbycountytn.gov |
www.gis.shelbycountytn.gov , ReGIS Shelby County Government
Willie F . Brooks, Jr.
Shelby County Register of Deeds
Parcel ID:
Owner Address:
Parcel Address:
Owner:
074102 00092
3575 EMERALD ST
L & A AUTOMOTIVE LLC
2635 FRIDDELL CV
Map prepared on 12/30/2025
2025 Appraisal: $194,600
T ax District: MEMPHIS
Year Built:
Lot Number: 6 & 7
Subdivision: EMERALD SQUARE
Plat BK & PG: UNKNOWN
Dimensions:
T otal Acres: 0.509
MEMPHIS TN
38133 5157
0 60 120
ft¯
Legend
polygonLayer
Override 1
Override 2
polylineLayer
Override 1
Roads
Parcels 0 0.03 0.06 0.09 0.12
mi
Map prepared through Shelby County Government's
online mapping Portal on 12/30/2025
¯
074102 00085C - MEMPHIS CATV
074102 00093 - CABLE HOLDCO II INC
074102 00092 - L & A AUTOMOTIVE LLC
093418 A00008 - SMITH JOANN
093418 A00009 - PAYNE JOHN L AND TRINA M PAYNE
093418 A00010 - PAYNE JOHN L AND TRINA M PAYNE
093418 A00011 - PAYNE JOHN L AND TRINA M PAYNE
093418 A00043 - GARCIA YANETH G
093418 A00014 - JECK FOUNDATION COMPANY
074102 A00049 - HARRIS TIMOTHY E
074102 00097 - CATHOLIC DIOCESE OF MEMPHIS
074102 00084 - DOZIER CARROLL T REV BISHOP
074102 00101 - GESTALT COMMUNITY SCHOOLS
074102 00091 - GIPSON LOVELACE P AND AMANDA T GIPSON
074102 00090 - AIC ENTERPRISES INC
074102 00089 - WAHAB SALAM
093418 A00001 - INDUSTRY DEVELOPMENT & CONSULTANTS LLC
093418 A00002 - INDUSTRY DEVELOPMENT & CONSULTANTS LLC
093418 A00003 - MALONE FAMILY LIVING TRUST FAMILY
093418 A00004 - HARMON OLIVER (ESTATE OF) AND JANICE H
093418 A00005C - COLEMAN CLARENCE W JR
093418 A00007 - SMITH JOANN
093418 A00012 - PAYNE JOHN L AND TRINA M PAYNE
093418 A00044 - GARCIA YANETH G
093418 A00013 - JECK FOUNDATION COMPANY
093418 A00042 - GARCIA YANETH G
093418 A00041 - GARCIA YANETH G
093418 A00040 - STARNES JIMMY W & GAIL O
074102 00087C - L AND A AUTOMOTIVE LLC
093400 A00016 - PCAMS HOLDINGS
093400 00598 - SANDLIAN LANCE B
093418 A00045 - WINCHESTER OFFICE PLAZA CONDOMINIUMS
093400 A00002 - PCAMS HOLDINGS
093400 A00001 - GESTALT COMMUNITY SCHOOLS
093400 A00015 - GESTALT COMMUNITY SCHOOLS
BUD GROUP
(Bacchus Urban Design Group)
Brian S. Bacchus, Principal Consultant
5320 White Diamond Street
Memphis, TN 38109
BacchusUrbanDesignGroup@Outlook.com
3575 Emerald Street
BUD Group
‘From the Property Line to the Parapet’
Memphis 3.0 Consistency Statement
3575 Emerald Street — Motor Vehicle Sales (SUP Request)
The proposed motor vehicle sales use is consistent with the Memphis 3.0 Comprehensive
Plan as it applies to the Low Intensity Commercial Services place type. This place type
supports neighborhood -scale commercial activity, small service businesses, and
auto-oriented commercial uses when designed to minimize off -site impacts. The proposal
maintains the intended character by:
• Reusing an existing commercial site without increasing intensity beyond what the
corridor already supports
• Limiting operations to low-impact vehicle sales with no repair, body work, or outdoor
storage of inoperable vehicles
• Providing site improvements such as landscaping, screening, and controlled access
that enhance the corridor’s appearance
• Maintaining compatibility with adjacent commercial and industrial properties while
buffering nearby residential uses
Memphis 3.0 emphasizes reinvestment in existing commercial corridors and supports
adaptive reuse of underutilized sites. This proposal aligns with those goals by activating a
vacant or underperforming parcel with a use that can be conditioned to remain low-intensity
and neighborhood-compatible.
BUD GROUP
(Bacchus Urban Design Group)
Brian S. Bacchus, Principal Consultant
5320 White Diamond Street
Memphis, TN 38109
BacchusUrbanDesignGroup@Outlook.com
3575 Emerald Street
BUD Group
‘From the Property Line to the Parapet’
Compatibility Argument
Impact on Adjacent Properties & Neighborhood Character
The proposed use will not adversely affect adjacent properties or the character of the
immediate area for the following reasons:
• Existing Context: The surrounding area already contains commercial and
light-industrial uses. Motor vehicle sales is consistent with the corridor’s established
development pattern.
• Low-Intensity Operations: The applicant proposes a small -format sales operation
with limited inventory, no outdoor repair activity, and no high -volume traffic
generation.
• Site Design Enhancements: Landscaping, fencing, and controlled access points
will improve the site’s appearance and reduce visibility of vehicles from the public
right-of-way.
• Traffic & Safety: The use does not introduce heavy truck traffic or high -turnover
vehicle movements. Access points remain unchanged or improved to meet UDC
standards.
• Noise & Lighting: Operations occur during normal business hours, with lighting
designed to avoid spillover onto adjacent properties.
With these conditions, the use is compatible with nearby development and does not create
negative externalities.
BUD GROUP
(Bacchus Urban Design Group)
Brian S. Bacchus, Principal Consultant
5320 White Diamond Street
Memphis, TN 38109
BacchusUrbanDesignGroup@Outlook.com
3575 Emerald Street
BUD Group
‘From the Property Line to the Parapet’
Staff-Friendly Narrative
Purpose & Intent
The applicant seeks approval of a Special Use Permit to allow a small -scale motor vehicle
sales establishment at 3575 Emerald Street. The intent is to activate an existing commercial
property with a low -impact use that aligns with the corridor’s character and the Memphis
3.0 vision for reinvestment in established commercial areas.
Consistency With Surrounding Developments
The site is located within a corridor characterized by commercial services, auto -oriented
uses, and light industrial activity. The proposed use fits within this context and does not
introduce a new or incompatible development pattern. The scale of the operation is modest,
and the applicant is committed to meeting all UDC requirements for landscaping, buffering,
and site design.
Public Interest & Neighborhood Benefit
The project improves an underutilized site, enhances the streetscape through required
landscaping, and provides controlled, well -maintained commercial use. No adverse
impacts on traffic, noise, or adjacent residential areas are anticipated. The proposal
supports economic activity while maintaining the low-intensity character envisioned for this
area.
CITY OF MEMPHIS
COUNCIL AGENDA CHECK OFF SHEET
___________________________________________________________________________________
| ONE ORIGINAL | Planning & Development
| ONLY STAPLED | DIVISION
|TO DOCUMENTS| Planning & Zoning COMMITTEE: 0 3/24/2026
DATE
PUBLIC SESSION: 04/ 14/2026
DATE
ITEM (CHECK ONE)
ORDINANCE X RESOLUTION REQUEST FOR PUBLIC HEARING
= = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = =
ITEM DESCRIPTION: Resolution pursuant to Chapter 9.6 of the Memphis and Shelby County Unified Development Code approving
a special use permit at the subject property located at 4180 Elliston Road, known as case number SUP 2026-
005
CASE NUMBER: SUP 2026-005
LOCATION: 4180 Elliston Road
COUNCIL DISTRICTS: District 4 and Super District 9 – Positions 1, 2, and 3
OWNER/APPLICANT: Leadership Preparatory, Inc.
REPRESENTATIVE: Doug Baker
REQUEST: To allow a childcare center
AREA: +/- 40,423 square feet
RECOMMENDATION: The Division of Planning and Development recommended Approval with conditions
The Land Use Control Board recommended Approval with conditions
RECOMMENDED COUNCIL ACTION: Public Hearing Not Required
Hearing – April 14, 2026
= = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = =
PRIOR ACTION ON ITEM:
(1) APPROVAL - (1) APPROVED (2) DENIED
03/12/2026 DATE
(1) Land Use Control Board ORGANIZATION - (1) BOARD / COMMISSION
(2) GOV’T. ENTITY (3) COUNCIL COMMITTEE
= = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = =
FUNDING:
(2) REQUIRES CITY EXPENDITURE - (1) YES (2) NO
$ AMOUNT OF EXPENDITURE
$ REVENUE TO BE RECEIVED
SOURCE AND AMOUNT OF FUNDS
$ OPERATING BUDGET
$ CIP PROJECT #_______________________________
$ FEDERAL/STATE/OTHER
= = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = =
ADMINISTRATIVE APPROVAL: DATE POSITION
_____________________________________________ ____________ PLANNER II
_____________________________________________ ____________ DEPUTY ADMINISTRATOR
_____________________________________________ ____________ ADMINISTRATOR
_____________________________________________ ____________ DIRECTOR (JOINT APPROVAL)
_____________________________________________ ____________ COMPTROLLER
_____________________________________________ ____________ FINANCE DIRECTOR
_____________________________________________ ____________ CITY ATTORNEY
= = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = =
_____________________________________________ ____________ CHIEF ADMINISTRATIVE OFFICER
_____________________________________________ ____________ COMMITTEE CHAIRMAN
3/16/2026
3/16/2026
3/16/2026
Memphis City Council
Summary Sheet
SUP 2026-005
RESOLUTION PURSUANT TO CHAPTER 9.6 OF THE MEMPHIS AND SHELBY COUNTY
UNIFIED DEVELOPMENT CODE APPROVING A SPECIAL USE PERMIT AT THE SUBJECT
PROPERTY LOCATED AT 4180 ELLISTON ROAD, KNOWN AS CASE NUMBER SUP 2026-005
• This item is a r esolution with conditions for a special use permit to allow a
childcare center; and
• The item may require future public improvement contracts.
1
LAND USE CONTROL BOARD RECOMMENDATION
At its regular meeting on Thursday, March 12, 2026, the Memphis and Shelby County Land Use Control
Board held a public hearing on the following application:
CASE NUMBER: SUP 2026-005
LOCATION: 4180 Elliston Road
COUNCIL DISTRICT(S): District 4 and Super District 9 – Positions 1, 2, and 3
OWNER/APPLICANT: Leadership Preparatory, Inc.
REPRESENTATIVE: Doug Baker
REQUEST: To allow a childcare center
EXISTING ZONING: Residential Single-Family – 6 (R-6)
AREA: +/- 40,423 square feet
The following spoke in support: None
The following spoke in opposition: None
The Land Use Control Board reviewed the application and the staff report. A motion was made and
seconded to recommend approval with conditions.
The motion passed by a vote of 8-0 on the consent agenda.
Respectfully,
Chloe Christion
Planner II
Land Use and Development Services
Division of Planning and Development
Cc: Committee Members
File
2
SUP 2026-005
CONDITIONS
1. The exact location of the crosswalk shall be determined and approved by the City Engineer via the
Administrative Site Plan Review (ASPR) process.
2. A Class III Buffer shall be provided along the western property line. An alternative buffer may be
approved through the site plan review process by the Division of Planning and Development.
3. A final site/landscape plan shall be submitted subject to the review and approval of the Division of
Planning and Development.
3
SITE PLAN
RESOLUTION PURSUANT TO CHAPTER 9.6 OF THE MEMPHIS AND SHELBY COUNTY
UNIFIED DEVELOPMENT CODE APPROVING A SPECIAL USE PERMIT AT THE SUBJECT
PROPERTY LOCATED AT 4180 ELLISTON ROAD , KNOWN AS CASE NUMBER SUP 2026-
005
WHEREAS, Chapter 9.6 of the Memphis and Shelby County Unified Development Code, being a
section of the Joint Ordinance Resolution No. 5367, dated August 10, 2010, authorizes the Council of the
City of Memphis to grant a special use permit for certain stated purposes in the various zoning districts;
and
WHEREAS, Leadership Preparatory, Inc. filed an application with the Memphis and Shelby
County Division of Planning and Development to allow a childcare center; and
WHEREAS, the Division of Planning and Development has received and reviewed the application
in accordance with procedures, objectives, and standards for special use permits as set forth in Chapter 9.6
with regard to the proposed development's impacts upon surrounding properties, availability of public
facilities, both external and internal circulation, land use compatibility, and that the design and amenities
are consistent with the public interest; and has submitted its findings and recommendation concerning the
above considerations to the Land Use Control Board; and
WHEREAS, a public hearing in relation thereto was held before the Memphis and Shelby County
Land Use Control Board on March 12, 2026, a nd said Board has submitted its findings and
recommendation concerning the above considerations to the Council of the City of Memphis; and
WHEREAS, the Council of the City of Memphis has reviewed the aforementioned application
pursuant to Tennessee Code Annotated Section 13-4- 202(B)(2)(B)(iii) and has determined that said
development is consistent with the Memphis 3.0 General Plan; and
WHEREAS, the Council of the City of Memphis has reviewed the recommendation of the Land
Use Control Board and the report and recommendation of the Division of Planning and Development and
has determined that said development meets the objectives, standards and criteria for a special use permit,
and said development is consistent with the public interests.
NOW, THEREFORE, BE IT RESOLVED, BY THE COUNCIL OF THE CITY OF
MEMPHIS, that, pursuant to Chapter 9.6 of the Memphis and Shelby County Unified Development Code,
a special use permit is hereby granted for the request use in accordance with the attached conditions.
BE IT FURTHER RESOLVED , that this permit merely authorizes the filing of applications to
acquire a Certificate of Use and Occupancy, or a Building Permit, and other required permits and approvals,
provided that no such Certificate of Use and Occupancy shall be granted until all conditions imposed by
the Council of the City of Memphis have been met.
BE IT FURTHER RESOLVED , that this Resolution take effect from and after the date it shall
have been passed by this Council of the City of Memphis, and become effective as otherwise provided by
law, and thereafter shall be treated as in full force and effect by virtue of passage thereof by the Council of
the City of Memphis, the public welfare requiring same.
CONDITIONS
1. The exact location of the crosswalk shall be determined and approved by the City Engineer via the
Administrative Site Plan Review (ASPR) process.
2. A Class III Buffer shall be provided along the western property line. An alternative buffer may be
approved through the site plan review process by the Division of Planning and Development.
3. A final site/landscape plan shall be submitted subject to the review and approval of the Division of
Planning and Development.
SITE PLAN
ATTEST:
CC: Division of Planning and Development
– Land Use and Development Services
– Office of Construction Enforcement
Staff Writer: Chloe Christion E-mail: chloe.christion@memphistn.gov
AGENDA ITEM: 12 L.U.C.B. MEETING: March 12, 2026
CASE NUMBER: SUP 2026-0005
LOCATION: 4180 Elliston Road
COUNCIL DISTRICT: District 4 and Super District 9 – Positions 1, 2, and 3
OWNER/APPLICANT: Leadership Preparatory, Inc.
REPRESENTATIVE: Doug Baker
REQUEST: Special use permit to allow a childcare center
EXISTING ZONING: Residential Single-Family – 6 (R-6)
CONCLUSIONS
1. The applicant is proposing to construct a day care facility for Leadership Prep Charter School. The facility
would accommodate up to twenty-three children ages 6 months to 4 years old. Operating hours would
be from 6:30AM to 2:00 PM in order to minimize conflicts with the schools operating times of 8:00 AM
to 3:30 PM.
2. Upon the request of staff, the applicant has submitted a revised site plan with a crosswalk across Elliston
Road. Note that the exact location of the crosswalk would be determined by the City Engineer prior to
the approval of any building permits.
3. The proposed site plan provides a 10’ Class II Type A landscape buffer along the western property line,
however per UDC 2.6.2B(1)(b), a Class III buffer is required. The applicant has the option to provide a 7’
or 10’ Class III buffer along the western property line.
4. The granting of this special use permit will not cause substantial detriment to the public good, nor will
it substantially impair the intent and purpose of an adopted plan or the Unified Development Code
(UDC), nor will it be injurious to the neighborhood or the general welfare, and it will be in harmony with
the purpose and intent of the UDC.
CONSISTENCY WITH MEMPHIS 3.0
This proposal is not applicable with the Memphis 3.0 General Plan per the land use decision criteria.
RECOMMENDATION:
Approval with conditions
Staff Report March 12, 2026
SUP 2026-0005 Page 2
2
LOCATION MAP
Subject property located within the pink circle
SUBJECT PROPERTY
Staff Report March 12, 2026
SUP 2026-0005 Page 3
3
PUBLIC NOTICE VICINITY MAP
Subject property outlined in red
PUBLIC NOTICE DETAILS
In accordance with Sub-Section 9.3.4A of the Unified Development Code, a notice of public hearing is required
to be mailed and signage posted. A total of 170 notices were mailed on February 20, 2026 , see page 19 of this
report for a copy of said notice . Additionally, one sign was posted at the subject property, see page 20 of this
report for a copy of the sign affidavit.
NEIGHBORHOOD MEETING
The meeting was held at 6:00 PM on February 26, 2026, at 4190 Elliston Road.
Staff Report March 12, 2026
SUP 2026-0005 Page 4
4
E L ROGERS EAST MEMPHIS PARK SUBDIVISION (1933) (PLAT BOOK 9 PAGE 103)
Subject property highlighted in yellow, part of Lot 19
Staff Report March 12, 2026
SUP 2026-0005 Page 5
5
AERIAL
Subject property outlined in yellow, imagery from 2025
Staff Report March 12, 2026
SUP 2026-0005 Page 6
6
ZONING MAP
Subject property highlighted in yellow
Staff Report March 12, 2026
SUP 2026-0005 Page 7
7
LAND USE MAP
Subject property indicated by a pink star
Staff Report March 12, 2026
SUP 2026-0005 Page 8
8
SITE PHOTOS
View of existing residence to be demolished on subject property from Elliston Road facing north.
View of Leadership Prep Charter School from Elliston Road facing north.
Staff Report March 12, 2026
SUP 2026-0005 Page 9
9
View of Leadership Prep Charter School parking lot.
Staff Report March 12, 2026
SUP 2026-0005 Page 10
10
SITE PLAN
Staff Report March 12, 2026
SUP 2026-0005 Page 11
11
SITE PLAN – MAGNIFIED
Staff Report March 12, 2026
SUP 2026-0005 Page 12
12
CASE REVIEW
Request
The request is a special use permit to allow a childcare center.
Approval Criteria
Staff agrees t he approval criteria in regard to special use permits as set out in Section 9. 6.9 of the Unified
Development Code are met.
9.6.9 Approval Criteria
No special use permit or planned development shall be approved unless the following findings are made
concerning the application:
9.6.9A The project will not have a substantial or undue adverse effect upon adjacent property, the
character of the neighborhood, traffic conditions, parking, utility facilities and other matters
affecting the public health, safety, and general welfare.
9.6.9B The project will be constructed, arranged and operated so as to be compatible with the
immediate vicinity and not interfere with the development and use of adjacent property in
accordance with the applicable district regulations.
9.6.9C The project will be served adequately by essential public facilities and services such as streets,
parking, drainage, refuse disposal, fire protection and emergency services, water and sewers; or
that the applicant will provide adequately for such services.
9.6.9D The project will not result in the destruction, loss or damage of any feature determined by the
governing bodies to be of significant natural, scenic or historic importance.
9.6.9E The project complies with all additional standards imposed on it by any particular provisions
authorizing such use.
9.6.9F The request will not adversely affect any plans to be considered (see Chapter 1.9), or violate the
character of existing standards for development of the adjacent properties.
9.6.9G The governing bodies may impose conditions to minimize adverse effects on the neighborhood
or on public facilities, and to ensure compatibility of the proposed development with surrounding
properties, uses, and the purpose and intent of this development code.
9.6.9H Any decision to deny a special use permit request to place, construct, or modify personal wireless
service facilities shall be in writing and supported by substantial evidence contained in a written
record, per the Telecommunications Act of 1996, 47 USC 332(c)(7)(B)(iii). The review body may
not take into account any environmental or health concerns.
Site Details
Address:
4180 Elliston Road
Parcel ID:
058161 00030 and 058161 00026C
Area:
+/- 40,423 square feet
Description:
Staff Report March 12, 2026
SUP 2026-0005 Page 13
13
The subject property is a part of lot 19 of the EL Rogers East Memphis Park Subdivision recorded in plat book 9,
page 103. The property is zoned Residential Single -Family – 6 (R-6). Per the Assessor’s website, the principal
structure on the property is a single-family residence built in 1942 with a ground floor area of 920 square feet.
The principal structure to the east is a charter school. There is one street frontage on the subject property along
Elliston Road, and a surface parking lot. Note there is a sha red parking agreement between the school and
Elliston Church on Elliston Road directly south of the subject property.
Relevant Unified Development Code Clauses
Paragraph 2.6.2C(4)
Public and private schools shall be required to obtain a special use permit prior to 1) installing or constructing a
principal or accessory use or structure on a platted residential lot that does not abut a connector or arterial, or
2) using a platted residential lot that does not abut a connector or arterial for any principal or accessory use.
Site Plan Review
• Existing residential unit to be demolished
• 1,895 s.f. proposed daycare facility
• 10’ Class II Type A Landscaping buffer along western property line with 6’ sight-proof fence
• Required streetscape trees along Elliston Road are insufficient. Four additional street trees along Elliston
Road are required.
• Shared parking agreement with Leadership Prep and Elliston Church
• Proposed crosswalk across Elliston Road
• Playground area to the rear of the structure
Analysis
The applicant is proposing to construct a day care facility for Leadership Prep Charter School. The facility would
accommodate up to twenty-three children ages 6 months to 4 years old. Operating hours would be from 6:30AM
to 2:00 PM in order to minimize conflicts with the schools operating times of 8:00 AM to 3:30 PM.
Upon the request of staff, the applicant has submitted a revised site plan with a crosswalk across Elliston Road.
Note that the exact location of the crosswalk would be determined by the City Engineer prior to the approval of
any building permits.
The proposed site plan provides a 10’ Class II Type A landscape buffer along the western property line, however
per UDC 2.6.2B(1)(b), a Class III buffer is required. The applicant has the option to provide a 7’ or 10’ Class III
buffer along the western property line.
The granting of this special use permit will not cause substantial detriment to the public good, nor will it
substantially impair the intent and purpose of an adopted plan or the Unified Development Code (UDC), nor will
it be injurious to the neighborhood or the general welfare, and it will be in harmony with the purpose and intent
of the UDC.
Staff Report March 12, 2026
SUP 2026-0005 Page 14
14
RECOMMENDATION
Staff recommends approval with conditions.
Conditions
1. The exact location of the crosswalk shall be determined and approved by the City Engineer via the
Administrative Site Plan Review (ASPR) process.
2. A Class III Buffer shall be provided along the western property line. An alternative buffer may be approved
through the site plan review process by the Division of Planning and Development.
3. A final site/landscape plan shall be submitted subject to the review and approval of the Division of Planning
and Development.
Staff Report March 12, 2026
SUP 2026-0005 Page 15
15
DEPARTMENTAL COMMENTS
The following comments were provided by agencies to which this application was referred:
City Engineer: See pages 17-18.
County Engineer: No comments received.
City Fire Division:
1. All design and construction shall comply with the 2021 edition of the International Fire Code with local
amendments and referenced standards.
2. Fire apparatus access shall comply with section 503.
3. Where security gates are installed that affect required fire apparatus access roads, they shall comply
with section 503.6.
4. Fire protection water supplies (including fire hydrants) shall comply with section 507.
5. Where fire apparatus access roads or a water supply for fire protection are required to be installed, such
protection shall be installed and made serviceable prior to and during the time of construction except
when approved alternate methods of protection are provided.
6. IFC 510 In-building two-way emergency responder communication coverage shall be provided in all new
and existing buildings. Buildings and structures that cannot support the required level of coverage shall
be equipped with systems and components to enhance signals and achieve the required level of
communication coverage.
7. A detailed plans review will be conducted by the Memphis Fire Prevention Bureau upon receipt of
complete construction documents. Plans shall be submitted to the Shelby County Office of Code
Enforcement.
County Fire Division: No comments received.
City Real Estate: No comments received.
County Health Department: No comments received.
Shelby County Schools: No comments received.
Construction Code Enforcement: No comments received.
Memphis Light, Gas and Water: No comments received.
Office of Sustainability and Resilience: No comments received.
Staff Report March 12, 2026
SUP 2026-0005 Page 16
16
Office of Comprehensive Planning: No comments received.
Staff Report March 12, 2026
SUP 2026-0005 Page 17
17
ENGINEERING COMMENTS
CASE 10: SUP-26-005; Childcare center in R-6 District
NAME: 4180 Elliston Rd; 05816100030
Basin/Lot/CD: Cherry Bayou, 6-A/.229ac/ 4
1. Standard Public Improvement Contract or Right-Of-Way Permit as required in Section 5.5.5 of the Unified
Development Code.
Sewers:
2. City sanitary sewers are available to serve this development.
3. A sanitary sewer service connection plan is required to be submitted (via 901 portal) to the City Land
Development Office for review and approval.
4. All required design plans and potential traffic control plan must be prepared in accordance with the City’s
Standard Requirements and must be stamped by a Professional Engineer registered in the State of
Tennessee.
5. A Sewer Development fee may be required per the City of Memphis Sewer Use Ordinance.
Roads:
6. The Developer shall be responsible for the repair and/or replacement of all existing curb and gutter along
the frontage of this site as necessary.
7. All existing sidewalks and curb openings along the frontage of this site shall be inspected for ADA
compliance. The developer shall be responsible for any reconstruction or repair necessary to meet City
standards.
Traffic Control Provisions:
8. The developer shall provide a traffic control plan to the city engineer that shows the phasing for each
street frontage during demolition and construction of curb gutter and sidewalk. Upon completion of
sidewalk and curb and gutter improvements, a minimum 5 foot wide pedestrian pathway shall be provided
throughout the remainder of the project. In the event that the existing right of way width does not allow
for a 5 foot clear pedestrian path, an exception may be considered.
9. Any closure of the right of way shall be time limited to the active demolition and construction of sidewalks
and curb and gutter. Continuous unwarranted closure of the right of way shall not be allowed for the
duration of the project. The developer shall provide on the traffic control plan, the time needed per phase
to complete that portion of the work. Time limits will begin on the day of closure and will be monitored by
the Engineering construction inspectors on the job.
10. The developer’s engineer shall submit a Trip Generation Report that documents the proposed land use,
scope and anticipated traffic demand associated with the proposed development. A detailed Traffic Impact
Study will be required when the accepted Trip Generation Report indicates that the number for projected
Staff Report March 12, 2026
SUP 2026-0005 Page 18
18
trips meets or exceeds the criteria listed in Section 210-Traffic Impact Policy for Land Development of the
City of Memphis Division of Engineering Design and Policy Review Manual. Any required Traffic Impact
Study will need to be formally approved by the City of Memphis, Traffic Engineering Department.
Curb Cuts/Access:
11. The City Engineer shall approve the design, number, and location of curb cuts.
12. Any existing nonconforming curb cuts shall be modified to meet current City Standards or closed with
curb, gutter, and sidewalk.
Drainage:
13. A grading and drainage plan for the site shall be submitted to the City Engineer for review and approval
prior to recording of the final plat.
14. Drainage improvements, including possible on-site detention, shall be provided under a Standard
Subdivision contract in accordance with Unified Development Code and the City of Memphis/Shelby
County Storm Water Management Manual.
15. Drainage data for assessment of on-site detention requirements shall be submitted to the City Engineer.
16. The following note shall be placed on the final plat of any development requiring on-site storm water
detention facilities: The areas denoted by "Reserved for Storm Water Detention" shall not be used as a
building site or filled without first obtaining written permission from the City and/or County Engineer. The
storm water detention systems located in these areas, except for those parts located in a public drainage
easement, shall be owned and maintained by the property owner and/or property owners' association.
Such maintenance shall be performed so as to ensure that the system operates in accordance with the
approved plan on file in the City and/or County Engineer's Office. Such maintenance shall include, but not
be limited to removal of sedimentation, fallen objects, debris and trash, mowing, outlet cleaning, and
repair of drainage structures.
17. The developer should be aware of his obligation under 40 CFR 122.26(b)(14) and TCA 69-3-101 et. seq. to
submit a Notice of Intent (NOI) to the Tennessee Division of Water Pollution Control to address the
discharge of storm water associated with the clearing and grading activity on this site.
18. Development is located within a sensitive drainage basin and requires detention, drainage and grading
engineering review.
Staff Report March 12, 2026
SUP 2026-0005 Page 19
19
MAILED PUBLIC NOTICE
Staff Report March 12, 2026
SUP 2026-0005 Page 20
20
SIGN AFFIDAVIT
Staff Report March 12, 2026
SUP 2026-0005 Page 21
21
APPLICATION
Staff Report March 12, 2026
SUP 2026-0005 Page 22
22
Staff Report March 12, 2026
SUP 2026-0005 Page 23
23
Staff Report March 12, 2026
SUP 2026-0005 Page 24
24
Staff Report March 12, 2026
SUP 2026-0005 Page 25
25
Staff Report March 12, 2026
SUP 2026-0005 Page 26
26
Staff Report March 12, 2026
SUP 2026-0005 Page 27
27
Staff Report March 12, 2026
SUP 2026-0005 Page 28
28
Staff Report March 12, 2026
SUP 2026-0005 Page 29
29
OWNER AFFIDAVIT
Staff Report March 12, 2026
SUP 2026-0005 Page 30
30
LETTER OF INTENT
Staff Report March 12, 2026
SUP 2026-0005 Page 31
31
Staff Report March 12, 2026
SUP 2026-0005 Page 32
32
Staff Report March 12, 2026
SUP 2026-0005 Page 33
33
Staff Report March 12, 2026
SUP 2026-0005 Page 34
34
Staff Report March 12, 2026
SUP 2026-0005 Page 35
35
Staff Report March 12, 2026
SUP 2026-0005 Page 36
36
LETTERS RECEIVED
One letter of opposition was received at the time of completion of this report and ha s subsequently been
attached.
Outlook
SUP 2026-005
From Glenn Little <oldsouthproperties@gmail.com>
Date Mon 3/2/2026 12:16 PM
To Christion, Chloe <Chloe.Christion@memphistn.gov>
CAUTION: This email originated outside of the City of Memphis organization. Do not click links or open attachments unless you recognize the
sender and know the content is safe.
To Whom It May Concern,
I am writing to formally express my concerns regarding the proposed childcare charter school development near
residential properties that I own.
While I support education and childcare services, I believe the proposed location raises significant concerns related to
traffic congestion, parking limitations, noise levels, and long-term impacts on nearby residents and property values.
The surrounding area consists primarily of residential housing, and the increased daily traffic and activity associated with a
school may create ongoing disruptions for tenants. I respectfully request that alternative locations be considered or that
additional studies and mitigation plans be required before approval is granted.
Thank you for allowing public input on this matter. I appreciate your consideration of the concerns raised by local property
owners and residents.
--
Thanks,
Glenn Little
O: 901-795-8000
3/2/26, 12:22 PM Mail - Christion, Chloe - Outlook
https://outlook.office365.com/mail/inbox/id/AAQkADM3YmYxNzI4LWY1NjUtNDlmNy1hYWE1LTZjNjAzMWRkYzBmOQAQAHX0Xkyuhn1DnrD7ryZWgt… 1/1
East Service Center: 6465 Mullins Station Rd; Memphis,
Tennessee
38134
Downtown Service Center: 125 N. Main Street;
Memphis, T
ennessee 38103
website: www.develop901.com
Memphis and Shelby County Division of
Planning and Development
Record Summary for Special Use Permit
Record Detail Information
Record T
ype: Special Use Permit Record Status: Pending
Opened Date:
January 30, 2026
Record Number: SUP 2026-005
Record Name: Leadership Prep Charter School Daycare Facility
Expiration Date:
Description of Work: Leadership Preparatory Charter School respectfully submits this application for a
Special Use Permit to establish the Leadership Prep Daycare at 4180 Elliston Road, Memphis,
Tennessee 38111. This proposed early childhood education facility will serve as a complementary
extension to the existing Leadership Preparatory Charter School campus, which currently operates an
elementary and middle school at adjacent properties on Elliston Road.
The daycare facility is designed to serve up to twenty-three children ranging from 6 months to 4 years of
age, with a staff of seven professionals. The facility will feature three specialized classrooms: an infant
room, a toddler room, and a pre-kindergarten room that will provide early educational instruction to
prepare children for their academic journey. Operating hours will be from 6:30 AM to 2:00 PM,
strategically scheduled to minimize traffic conflicts with the adjacent school’s operating schedule of 8:00
AM to 3:30 PM.
While the daycare will prioritize enrollment of children whose parents are employed at the adjacent
Leadership Preparatory schools, it will be open to serve the broader community. This approach aligns
with the school’s mission of supporting families and contributing to the educational infrastructure of the
neighborhood.
The subject property is in an R-6 zoning district with a Future Land Use designation of Anchor
Neighborhood; Primarily Single-Unit. The property is strategically positioned within an established
educational corridor, with the Leadership Preparatory Elementary School immediately to the east,
Elliston Baptist Church, and Academy to the south, and single-family residences to the west and north.
This context creates a natural educational cluster that enhances the compatibility of the proposed
daycare use. The proposed Leadership Prep Daycare fully complies with all R-6 zoning district
requirements for non-residential uses.
Parent Record Number:
Address:
4180 ELLISTON RD, MEMPHIS 381
11
Page 1 of 8 SUP 2026-005
Owner Information
Primary Owner Name
Owner Address Owner Phone
Y LEADERSHIP PREP
ARATORY INC
4190 ELLISTON RD, MEMPHIS, TN 38111
Parcel Information
058161 00030
Data Fields
PREAPPLICATION MEETING
Name of DPD Planner Chloe Christion
Date of Meeting 12/04/2025
Pre-application Meeting
Type Virtual
GENERAL PROJECT INFORMATION
Application Type New Special Use Permit (SUP)
List any relevant former Docket / Case
Number(s) related to previous applications on
this site
n/a
Is this application in response to a citation, stop
work order, or zoning letter
No
If yes, please provide a copy of the citation, stop
work order, and/or zoning letter along with any
other relevant information
-
APPROVAL CRITERIA
Page 2 of 8 SUP 2026-005
APPROVAL CRITERIA
A) The project will not have a substantial or
undue adverse effect upon adjacent property, the
character of the neighborhood,
traffic conditions,
parking, utility facilities and other matters
affecting the public health, safety, and general
welfare
The new single-story daycare building is designed
at residential scale and character, ensuring no
physical impact on adjacent properties beyond what
typical residential development would create. In
primarily residential areas, daycare facilities rank
among the most compatible institutional uses,
serving residents' daily needs without compromising
residential ambiance. The facility generates
approximately 15-20 vehicle trips during peak hours,
comparable to or less than a busy single-family
residence with multiple drivers. The 6:30 AM-2:00
PM operating schedule avoids typical or traditional
residential neighborhood peak hours (7:30-8:30 AM
and 5:00-6:30 PM), distributing traffic throughout
mid-day periods when residential streets
experience lower volumes. Twenty-four on-site
parking spaces, supplemented by 44 additional
spaces through a shared parking agreement with
Elliston Baptist Church, provide a total of 68 spaces,
significantly exceeding the 60-space requirement
and ensuring parking demand, ensuring no spillover
parking impacts on adjacent residential streets—a
significant improvement over typical single-family
residential parking that often relies on street
parking. New utility connections (water, sewer,
electrical) are sized appropriately for the daycare's
infrastructure needs, comparable to a large
single-family residence.
The daycare provides essential community
infrastructure supporting working families in the
neighborhood, enhancing rather than compromising
public welfare. The facility operates under strict state
licensing requirements ensuring health and safety
standards are met. Purpose-built early childhood
education facilities represent an ideal transitional
use between residential and institutional, serving
neighborhood families while maintaining residential
scale, appearance, and operational character
through thoughtful architectural design.
Page 3 of 8 SUP 2026-005
APPROVAL CRITERIA
B) The project will be constructed, arranged and
operated so as to be compatible with the
immediate vicinity and not interfere with the
development and use of adjacent property in
accordance with the applicable district
regulations
The new single-story daycare building is specifically
designed to maintain residential scale and
character appropriate for the R-6 district. At 1,895
square feet, the facility matches the footprint of a
single-family home while incorporating design
elements that complement neighboring residential
architecture. Purpose-built construction allows for
optimal site design that respects adjacent property
relationships better than retrofitting existing
structures.
The new construction will not interfere with adjacent
residential property development or use rights.
Operating hours (6:30 AM-2:00 PM) occur during
typical daytime periods when residential properties
experience minimal outdoor activity, avoiding
conflicts with evening family time, or weekend
activities. The new building placement and design
does not affect neighboring properties' ability to
develop, expand, or modify their residences within
R-6 regulations.
The new facility is engineered to fully comply with
R-6 setback requirements (20-foot front, 10-foot
side interior, 20-foot total side, 20-foot rear),
establishing appropriate spatial relationships to
adjacent properties. The single-story design
remains well below the 40-foot R-6 height limit,
preserving sight lines and privacy for neighboring
homes.
The new daycare facility logically completes the
established 3-property educational campus without
expanding institutional use into the broader
residential neighborhood. This concentrated
development approach protects surrounding
residential blocks from scattered institutional
development while creating a cohesive educational
node that serves neighborhood families.
The facility design enables pedestrian connections
that support the integrated educational campus
while maintaining compatibility with the residential
neighborhood context. The planned playground with
Class III buf
fering provides acoustic and visual
screening compared to typical residential
development, ensuring children's outdoor activities
enhance rather than impact adjacent residential
Page 4 of 8 SUP 2026-005
APPROVAL CRITERIA
enjoyment.
UDC Sub-Section 9.6.9C Elliston Road provides direct frontage access with
demonstrated capacity for the traffic the daycare will
generate. The existing elementary and middle
school operations on adjacent properties already
utilize this street infrastructure for much higher peak
traffic loads
(300+ students vs. 28 daycare children),
proving adequate capacity exists for the minimal
additional 15-20 daily trips.
Twenty-four dedicated on-site parking spaces,
combined with formalized shared parking
arrangements providing an additional 44 spaces,
eliminating any potential impact on existing school
parking or neighborhood street parking, while
providing ample capacity for both the daycare and
existing elementary school operations representing
a net improvement over typical residential
development that may often relies on street parking.
The single-story building design ensures optimal
emergency access, with all areas reachable within
150 feet of fire truck hose deployment from Elliston
Road. The purpose-built structure will incorporate
modern fire safety systems and clear emergency
egress routes, providing emergency response
capabilities compared to residential structures.
Municipal water and sewer infrastructure serving the
adjacent school campus has capacity for the
23-child daycare. The facility's water demand and
wastewater generation represent minimal
incremental load on existing infrastructure.
Adequate electrical service is available from
existing utility lines serving the educational campus,
with capacity sufficient for the daycare's modest
electrical demand.
Page 5 of 8 SUP 2026-005
APPROVAL CRITERIA
UDC Sub-Section 9.6.9D The project will not result in the destruction, loss or
damage of any feature determined to be of
significant natural, scenic, or historic importance.
The proposed development will not result in the
destruction, loss, or damage of any significant
natural, scenic, or historic features. The site
development has been designed to work with
existing topography and preserve existing mature
trees where possible. No historic structures or
features of significance have been identified on the
property.
The single-story building design and strategic
landscaping ensure no adverse impact on
neighborhood scenic character or important
viewsheds. The facility's residential-scale
architecture and Class II buffer landscaping will
enhance rather than detract from the area's visual
character.
UDC Sub-Section 9.6.9E The proposed daycare meets all additional R-6
district requirements for nonresidential special uses
through comprehensive site design that exceeds
minimum standards. Building setbacks meet
minimum requirements with 20 feet front setback, 10
feet side interior setback, 20 feet total side setback,
and 20 feet rear setback, while the single-story
height remains well below the 40-foot maximum
limit. The Class II landscaping buf
fers around future
playground area provide enhanced screening. The
building coverage ratios maintain residential
character appropriate for the R-6 district context.
The facility design will incorporate all Tennessee
Department of Human Services childcare licensing
requirements to ensure optimal child safety and
developmental programming. Construction will meet
all International Building Code requirements and will
also be in full compliance with all ADA requirements.
Page 6 of 8 SUP 2026-005
APPROVAL CRITERIA
UDC Sub-Section 9.6.9F The proposed daycare aligns comprehensively with
the Future Land Use designation of Anchor
Neighborhood, which specifically envisions
essential community services that support and
strengthen primarily residential areas. Early
childhood education facilities represent
quintessential anchor uses that provide necessary
infrastructure for working families while maintaining
neighborhood character and residential property
values. The facility serves the dual purpose of
supporting local economic vitality by enabling
parents to participate in the workforce while
providing educational services that enhance
community desirability and long-term stability.
The daycare's design and operational
characteristics are fully consistent with existing
development standards for adjacent properties
within the R-6 district. The single-story,
residential-scale building maintains the established
setback patterns, height relationships, and
architectural character that define the
neighborhood's development standards. The
facility's integration within the existing educational
campus creates a logical institutional cluster that
preserves the broader residential character while
concentrating compatible community-serving uses in
an appropriate location. This approach supports the
comprehensive planning goal of providing
neighborhood-scale services without compromising
residential land use patterns or property values.
GIS INFORMATION
Case Layer -
Central Business Improvement District No
Class R
Downtown Fire District No
Historic District -
Land Use SINGLE-F
AMILY
Municipality MEMPHIS
Overlay/Special Purpose District -
Zoning R-6
State Route -
Lot 0 19
Subdivision EAST MEMPHIS PARK
Planned Development District -
Wellhead Protection Overlay District Yes
County Commission District -
Page 7 of 8 SUP 2026-005
GIS INFORMATION
City Council District -
City Council Super District -
Data Tables
AREA
INFORMATION
Name: Leadership Prep Daycare
Size (Acres): 0.23
Existing Use of Property: Single Family Residential
Requested Use of
Property:
Daycare Facility
Contact Information
ETI CORPORATION
(901)383-3250
APPLICANT
Name
Address
Phone
Contact Type
Fee Information
Date
AssessedBalanceStatusFeesQuantityFee ItemInvoice #
01/30/20260.00INVOICED500.001Special Use Permit Fee -
5 acres or less (Base Fee)
1703715
01/30/20260.00INVOICED250.001Child Care Center (13+
children)
1703715
01/30/20260.00INVOICED19.501Credit Card Use Fee (.026
x fee)
1703715
Total Fee Invoiced
: $769.50 Total Balance: $0.00
Payment Information
Payment
Amount Method of Payment
Credit Card$769.50
Page 8 of 8 SUP 2026-005
January 30, 2026
Division of Planning and Development
125 North Main Street, Room 477
Memphis, TN 38103
RE: Letter of Intent and Justif ication - Special Use Permit Application
Leadership Preparatory Charter School
Proposed Daycare Facility
4180 Elliston Road, Memphis, TN 38111
Leadership Preparatory Charter School respectfully submits this application for a Special Use
Permit to establish the Leadership Prep Daycare at 4180 Elliston Road, Memphis, Tennessee
38111. This proposed early childhood education facility will serve as a complementary extension
to the existing Leadership Preparatory Charter School campus, which currently operates an
elementary and middle school at adjacent properties on Elliston Road.
Property Overview and Development Proposal
The daycare facility is designed to serve up to twenty-three children ranging from 6 months to 4
years of age, with a staff of seven professionals. The facility will feature three specialized
classrooms: an infant room, a toddler room, and a pre-kindergarten room that will provide early
educational instruction to prepare children for their academic journey. Operating hours will be
from 6:30 AM to 2:00 PM, strategically scheduled to minimize traffic conflicts with the adjacent
school’s operating schedule of 8:00 AM to 3:30 PM.
While the daycare will prioritize enrollment of children whose parents are employed at the
adjacent Leadership Preparatory schools, it will be open to serve the broader community. This
approach aligns with the school’s mission of supporting families and contributing to the
educational infrastructure of the neighborhood.
The subject property is in an R-6 zoning district with a Future Land Use designation of Anchor
Neighborhood; Primarily Single-Unit. The property is strategically positioned within an established
educational corridor, with the Leadership Preparatory Elementary School immediately to the east,
Elliston Baptist Church, and Academy to the south, and single-family residences to the west and
north. This context creates a natural educational cluster that enhances the compatibility of the
proposed daycare use. The proposed Leadership Prep Daycare fully complies with all R-6 zoning
district requirements for non-residential uses.
Special Use Permit Justification
The following analysis demonstrates that the proposed Leadership Prep Daycare meets all criteria
established in the Memphis/Shelby County Unified Development Code for Special Use Permit
approval:
ENGINEERING • SURVEYING • LAND PLANNING • LANDSCAPE ARCHTECTURE
PRINCIPALS
Mathew D. Wolfe
Christopher E. Perry
Douglas M. Baker
Steve R. Hooper
David M. Docauer
Leadership Preparatory Charter School Daycare Facility
January 30, 2026
Page 2 of 6
ETI CORPORATION ENGINEERING • SURVEYING • LAND PLANNING • LANDSCAPE ARCHITECTURE
1755 LYNNFIELD ROAD, SUITE 100 • MEMPHIS, TN 38119 • OFFICE (901) 758-0400 • FAX (901 754-5135 • ETICORP.COM
A. The project will not have a substantial or undue adverse effect upon adjacent property, the
character of the neighborhood, traffic conditions, parking, utility facilities and other matters
affecting the public health, safety, and general welfare.
The new single-story daycare building is designed at residential scale and character, ensuring no
physical impact on adjacent properties beyond what typical residential development would
create. In primarily residential areas, daycare facilities rank among the most compatible
institutional uses, serving residents' daily needs without compromising residential ambiance. The
facility generates approximately 15-20 vehicle trips during peak hours, comparable to or less than
a busy single-family residence with multiple drivers. The 6:30 AM-2:00 PM operating schedule
avoids typical or traditional residential neighborhood peak hours (7:30-8:30 AM and 5:00-6:30
PM), distributing traffic throughout mid-day periods when residential streets experience lower
volumes. Twenty-four on-site parking spaces, supplemented by 44 additional spaces through a
shared parking agreement with Elliston Baptist Church, provide a total of 68 spaces, significantly
exceeding the 60-space requirement and ensuring parking demand, ensuring no spillover parking
impacts on adjacent residential streets—a significant improvement over typical single-family
residential parking that often relies on street parking. New utility connections (water, sewer,
electrical) are sized appropriately for the daycare's infrastructure needs, comparable to a large
single-family residence.
The daycare provides essential community infrastructure supporting working families in the
neighborhood, enhancing rather than compromising public welfare. The facility operates under
strict state licensing requirements ensuring health and safety standards are met. Purpose-built
early childhood education facilities represent an ideal transitional use between residential and
institutional, serving neighborhood families while maintaining residential scale, appearance, and
operational character through thoughtful architectural design.
B. The project will be constructed, arranged and operated to be compatible with the immediate
vicinity and not interfere with the development and use of adjacent property in accordance with
the applicable district regulations.
The new single-story daycare building is specifically designed to maintain residential scale and
character appropriate for the R-6 district. At 1,895 square feet, the facility matches the footprint
of a single-family home while incorporating design elements that complement neighboring
residential architecture. Purpose-built construction allows for optimal site design that respects
adjacent property relationships better than retrofitting existing structures.
The new construction will not interfere with adjacent residential property development or use
rights. Operating hours (6:30 AM-2:00 PM) occur during typical daytime periods when residential
properties experience minimal outdoor activity, avoiding conflicts with evening family time, or
weekend activities. The new building placement and design does not affect neighboring
properties' ability to develop, expand, or modify their residences within R-6 regulations.
Leadership Preparatory Charter School Daycare Facility
January 30, 2026
Page 3 of 6
ETI CORPORATION ENGINEERING • SURVEYING • LAND PLANNING • LANDSCAPE ARCHITECTURE
1755 LYNNFIELD ROAD, SUITE 100 • MEMPHIS, TN 38119 • OFFICE (901) 758-0400 • FAX (901 754-5135 • ETICORP.COM
The new facility is engineered to fully comply with R-6 setback requirements (20-foot front, 10-
foot side interior, 20-foot total side, 20-foot rear), establishing appropriate spatial relationships to
adjacent properties. The single-story design remains well below the 40-foot R-6 height limit,
preserving sight lines and privacy for neighboring homes.
The new daycare facility logically completes the established 3-property educational campus
without expanding institutional use into the broader residential neighborhood. This concentrated
development approach protects surrounding residential blocks from scattered institutional
development while creating a cohesive educational node that serves neighborhood families.
The facility design enables pedestrian connections that support the integrated educational
campus while maintaining compatibility with the residential neighborhood context. The planned
playground with Class III buffering provides acoustic and visual screening compared to typical
residential development, ensuring children's outdoor activities enhance rather than impact
adjacent residential enjoyment.
C. The project will be served adequately by essential public facilities and services such as streets,
parking, drainage, refuse disposal, fire protection and emergency services, water, and sewers; or
that the applicant will provide adequately for such services.
Elliston Road provides direct frontage access with demonstrated capacity for the traffic the
daycare will generate. The existing elementary and middle school operations on adjacent
properties already utilize this street infrastructure for much higher peak traffic loads (300+
students vs. 28 daycare children), proving adequate capacity exists for the minimal additional 15-
20 daily trips.
Twenty-four dedicated on-site parking spaces, combined with formalized shared parking
arrangements providing an additional 44 spaces, eliminating any potential impact on existing
school parking or neighborhood street parking, while providing ample capacity for both the
daycare and existing elementary school operations representing a net improvement over typical
residential development that may often relies on street parking.
The single-story building design ensures optimal emergency access, with all areas reachable within
150 feet of fire truck hose deployment from Elliston Road. The purpose-built structure will
incorporate modern fire safety systems and clear emergency egress routes, providing emergency
response capabilities compared to residential structures.
Municipal water and sewer infrastructure serving the adjacent school campus has capacity for the
23-child daycare. The facility's water demand and wastewater generation represent minimal
incremental load on existing infrastructure. Adequate electrical service is available from existing
utility lines serving the educational campus, with capacity sufficient for the daycare's modest
electrical demand.
Leadership Preparatory Charter School Daycare Facility
January 30, 2026
Page 4 of 6
ETI CORPORATION ENGINEERING • SURVEYING • LAND PLANNING • LANDSCAPE ARCHITECTURE
1755 LYNNFIELD ROAD, SUITE 100 • MEMPHIS, TN 38119 • OFFICE (901) 758-0400 • FAX (901 754-5135 • ETICORP.COM
D. The project will not result in the destruction, loss or damage of any feature determined by
the governing bodies to be of significant natural, scenic or historic importance.
The project will not result in the destruction, loss or damage of any feature determined to be of
significant natural, scenic, or historic importance. The proposed development will not result in the
destruction, loss, or damage of any significant natural, scenic, or historic features. The site
development has been designed to work with existing topography and preserve existing mature
trees where possible. No historic structures or features of significance have been identified on the
property.
The single-story building design and strategic landscaping ensure no adverse impact on
neighborhood scenic character or important viewsheds. The facility's residential-scale architecture
and Class II buffer landscaping will enhance rather than detract from the area's visual character.
E. The project complies with all additional standards imposed on it by any particular provisions
authorizing such use.
The proposed daycare meets all additional R-6 district requirements for nonresidential special
uses through comprehensive site design that exceeds minimum standards. Building setbacks meet
minimum requirements with 20 feet front setback, 10 feet side interior setback, 20 feet total side
setback, and 20 feet rear setback, while the single-story height remains well below the 40-foot
maximum limit. The Class II landscaping buffers around future playground area provide enhanced
screening. The building coverage ratios maintain residential character appropriate for the R-6
district context.
The facility design will incorporate all Tennessee Department of Human Services childcare
licensing requirements to ensure optimal child safety and developmental programming.
Construction will meet all International Building Code requirements and will also be in full
compliance with all ADA requirements.
F. The request will not adversely affect any plans to be considered (see Chapter 1.9) or violate
the character of existing standards for development of the adjacent properties.
The proposed daycare aligns comprehensively with the Future Land Use designation of Anchor
Neighborhood, which specifically envisions essential community services that support and
strengthen primarily residential areas. Early childhood education facilities represent quintessential
anchor uses that provide necessary infrastructure for working families while maintaining
neighborhood character and residential property values. The facility serves the dual purpose of
supporting local economic vitality by enabling parents to participate in the workforce while
providing educational services that enhance community desirability and long-term stability.
The daycare's design and operational characteristics are fully consistent with existing
development standards for adjacent properties within the R-6 district. The single-story,
residential-scale building maintains the established setback patterns, height relationships, and
Leadership Preparatory Charter School Daycare Facility
January 30, 2026
Page 5 of 6
ETI CORPORATION ENGINEERING • SURVEYING • LAND PLANNING • LANDSCAPE ARCHITECTURE
1755 LYNNFIELD ROAD, SUITE 100 • MEMPHIS, TN 38119 • OFFICE (901) 758-0400 • FAX (901 754-5135 • ETICORP.COM
architectural character that define the neighborhood's development standards. The facility's
integration within the existing educational campus creates a logical institutional cluster that
preserves the broader residential character while concentrating compatible community-serving
uses in an appropriate location. This approach supports the comprehensive planning goal of
providing neighborhood-scale services without compromising residential land use patterns or
property values.
G. The governing bodies may impose conditions to minimize adverse effects on the
neighborhood or on public facilities, and to ensure compatibility of the proposed development
with surrounding properties, uses, and the purpose and intent of this development code.
The applicant acknowledges that the governing bodies may impose reasonable conditions to
minimize any potential adverse effects on the neighborhood or public facilities and to ensure
complete compatibility with surrounding properties and development code intent.
Community Benefits
Beyond meeting all regulatory requirements, the Leadership Prep Daycare will provide
measurable benefits that enhance community welfare and economic vitality. The facility creates
educational continuity by establishing a comprehensive Pre-K through 8th grade educational
pathway serving approximately 300+ students across the integrated campus, supporting family
stability and student academic success through seamless transitions between developmental
stages. This educational continuum reduces family stress and transportation burdens while
ensuring consistent educational philosophy and community connections throughout children's
formative years.
The daycare provides critical employment support infrastructure by enabling families to maintain
workforce participation through accessible, quality childcare services. The facility addresses a
documented childcare shortage in the area, providing working families with dependable,
neighborhood-based early childhood education that reduces commute times and strengthens
local economic participation.
The project represents new construction investment, demonstrating continued commitment to
the neighborhood's educational infrastructure and economic development. This investment
enhances property values throughout the surrounding residential area by providing desirable
community amenities that make the neighborhood more attractive to families with young
children. The facility's integration within the established educational campus creates a valuable
community asset that strengthens the area's identity as a family-friendly neighborhood with
excellent educational resources, contributing to long-term residential stability and property value
appreciation.
Conclusion
The proposed Leadership Prep Daycare represents a thoughtfully planned addition to the
established Leadership Preparatory educational campus that demonstrates comprehensive
compatibility with neighborhood character and zoning requirements. The application presents
compelling evidence of full compliance with all Special Use Permit criteria established in the
Memphis/Shelby County Unified Development Code. The project's design incorporates
measurable safeguards to protect adjacent residential uses while providing quantifiable
Leadership Preparatory Charter School Daycare Facility
January 30, 2026
Page 6 of 6
ETI CORPORATION ENGINEERING • SURVEYING • LAND PLANNING • LANDSCAPE ARCHITECTURE
1755 LYNNFIELD ROAD, SUITE 100 • MEMPHIS, TN 38119 • OFFICE (901) 758-0400 • FAX (901 754-5135 • ETICORP.COM
community benefits including educational continuity, employment support for working families,
and significant neighborhood investment. We respectfully submit that this comprehensive
demonstration of regulatory compliance and community benefit warrants favorable
consideration.
We are prepared to work collaboratively with city staff throughout the review process to address
any questions or concerns that may arise, and we welcome the opportunity to provide additional
information if needed.
Thank you for your consideration of this important community investment that will provide
essential early childhood education infrastructure while preserving and enhancing the residential
character of this established neighborhood.
Please contact ETI if you need additional information or have any questions.
Respectfully submitted,
Anita Archambeau, DPA, AICP
M:\25036\-10\LETTER OF INTENT.DOC
Attachments:
N5°40'56"E 200.04'
S5°40'56"W 200.00'
S84°42'53"E 50.00'
N84°45'07"W 50.00'
10' BUILDING SETBACK
& CLASS II TYPE A
LANDSCAPE SCREEN 10'
20'
EX. 25'
CURBCUT
20' BUILDING
SETBACK
10' BUILDING
SETBACK
10'
20'
20' BUILDING
SETBACK
10' BUILDING SETBACK
& CLASS II TYPE A
LANDSCAPE SCREEN
PROPOSED
DAYCARE
FACILITY
1,895 S.F.
F.F.E.=268.35
EX. EDUCATIONAL BUILDING
TOTAL CLASSROOM S.F. = ±9,620
GROSS BUILDING S.F. = ±14,730
F.F.E.=267.28
FUTURE
PLAYGROUND
76.9'
29.7'
23.6'
43.25
EX. SIDEWALK
6-FOOT HEIGHT
OPAQUE FENCE
EX. PARKING LOT
20 SPACES
44.5'
±22'
EXISTING
HANDICAP
PARKING
ELLISTON ROAD
50' R.O.W.
WATSON ST.
COVERED
PATIO
EX. 36''
OAK TREE
EX. 36''
OAK TREE
6-FOOT HEIGHT
OPAQUE FENCE
CHAIN LINK
FENCE
5' SIDEWALK
MARIA CRUZ
(I.N. 20103585)
LEADERSHIP PREPARATORY
CHARTER SCHOOL
(I.N. 20040518)
JOHNSON BURTON
(I.N. 14070522)
HERSHEL JONES, JR.
(I.N. 07011780)
ELLISTON BAPTIST CHURCH
& ACADEMY INC.
EAST MEMPHIS PARK SUB,
P.B. 9 PG. 103
EX. FIRE
HYDRANT
±375' TO THE WEST R.O.W
LINE OF S. GOODLETT ST.
10.3'
10.2'
10'
16.5'
10'
SHARED PARKING
AGREEMENT WITH
LEADERSHIP
PREPARATORY
CHARTER SCHOOL
44 PARKING SPACES
50'30'
15'
15'
EXISTING
SIGN
OE OE
OE OE OE OE OE OE
OE OE OE OE
OEOE
OE OE OE OE OE OE OE
OE
OE OE OE
OE
OE
OE
OE
OE
PP
PP
PP
PP
PP
EX. OVERHEAD
ELECTRIC
EX. OVERHEAD
ELECTRIC
SCHOOL
PROPERTY
LINE
SCHOOL
PROPERTY
LINE
6' SIDEWALK
EX. SIDEWALK
10' BUILDING
SETBACKEX. 24''
PECAN
VICINTY MAP
SITE PLAN
NORTH
SCALE: 1" = 20'
20 10 0 20 40
SHEET 1 OF 3SHEET
ZONING: R-6
MEMPHIS, TENNESSEE
NUMBER OF LOTS: 01 ACREAGE: 0.2296 ACRES
DEVELOPER:
100-YEAR FLOOD ELEVATION:
ENGINEER :
FEMA MAP PANEL NUMBER:
SCALE: 1" = 20'
FEMA MAP DATE:
47157C0435F SEPTEMBER 28, 2007
ETI CORPORATION
1755 LYNNFIELD ROAD, SUITE 100
MEMPHIS, TN. 38119
-
LEADERSHIP PREPARATORY CHARTER SCHOOL
4190 ELLISTON ROAD
MEMPHIS, TN 38111
WARD ___, BLOCK ___,
PARCELS ____
58 161
30
DATE: JANUARY 2026
CASE NUMBER: SUP
FINAL PLAT
LEADERSHIP PREPARATORY CHARTER SCHOOL
SITE DATA CHART
PROPERTY ZONING: R-6
PROPERTY USE: DAY CARE
PROPOSED PROPERTY ACREAGE: 0.23 ACRES
DAY CARE GROSS SPACE: 1,895 S.F.
TOTAL INDIVIDUAL OCCUPANCY: 30
PARKING REQUIRED (1 Space/5 Indiv.): 6 SPACES
EX. ELEMENTARY CLASSROOM TOTAL S.F.: ±9,620
PARKING REQUIRED (1 SPACE/300 S.F.): 32 SPACES
ONSITE PARKING PROVIDED: 24 SPACES
OFFSITE PARKING PROVIDED: 44 SPACES
(ELLISTON BAPTIST CHURCH)
FRONT YARD BUILDING SETBACK: 20-FEET
SIDE YARD BUILDING SETBACK: 10-FEET
REAR YARD BUILDING SETBACK: 20-FEET
SITE
City Hall – 125 N. Main Street, Suite 468 – Memphis, Tennessee 38103 – (901) 636-6619
March 12, 2026
Doug Baker
ETI Corporation
1755 Lynnfield Road, Suite 100
Memphis, TN 38119
Sent via electronic mail to: dbaker@eticorp.com
Case Number: SUP 2026-0005
LUCB Recommendation: Approval with conditions
Dear applicant,
On Thursday, March 12, 2026 , t he Memphis and Shelby County Land Use Control Board
recommended approval of your special use permit application to allow a childcare center located
at 4180 Elliston Road subject to the following conditions:
1. The exact location of the crosswalk shall be determined and approved by the City Engineer via
the Administrative Site Plan Review (ASPR) process.
2. A Class III Buffer shall be provided along the western property line. An alternative buffer may
be approved through the site plan review process by the Division of Planning and Development.
3. A final site/landscape plan shall be submitted subject to the review and approval of the Division
of Planning and Development.
This application will be forwarded, for final action, to the Council of the City of Memphis. The Council
will review your application in a committee meeting prior to voting on it in a public hearing. The
applicant or the applicant’s representative(s) shall be in attendance at all meetings and hearings.
It is the applicant’s responsibility to contact the City Council Records Office to determine when the
application is scheduled to be heard at committee and in public session. The City Council Records
Office may be reached at (901) 636-6792.
If for some reason you choose to withdraw your application, a letter should be mailed to the Land
Use and Development Services Department of the Division of Planning and Development at the
address provided above or emailed to the address provided below.
Letter to Applicant
SUP 2026-0005
Page 2 of 2
If you have questions regarding this matter, please feel free to contact me at (901) 636-6619 or via
email at chloe.christion@memphistn.gov.
Respectfully,
Chloe Christion
Planner II
Land Use and Development Services
Division of Planning and Development
Cc: Anita Archambeau – ETI Corporation
Matt Wolfe – ETI Corporation
Valissia Allen – Lead Memphis
File
Memphis City Council
Summary Sheet
Z 2026-001
ZONING ORDINANCE AMENDING ORDINANCE NO. 5367 OF CODE OF ORDINANCE, CITY OF
MEMPHIS, TENNESSEE, ADOPTED ON AUGUST 10, 2010, AS AMENDED, KNOWN AS THE MEMPHIS
AND SHELBY COUNTY UNIFIED DEVELOPMENT CODE, TO AUTHORIZE A ZONING USE DISTRICT
RECLASSIFICATION FOR LAND LOCATED ON TULLY STREET AND WOODLAWN STREET. BY TAKING
THE LAND OUT OF THE RESIDENTIAL URBAN – 1 (RU-1) USE DISTRICT AND INCLUDING IT IN THE
MIXED USE (MU) USE DISTRICT, KNOWN AS CASE NUMBER Z 2026-001
• Approval of this zoning district reclassification will be reflected on the Memphis
and Shelby County Zoning Atlas; and
• No contracts are affected by this item; and
• No expenditure of funds/budget amendments are required by this item.
1
LAND USE CONTROL BOARD RECOMMENDATION
At its regular meeting on Thursday, February 12, 2026, the Memphis and Shelby County Land Use Control
Board held a public hearing on the following application:
CASE NUMBER: Z 2026-001
LOCATION: Tully Street and Woodlawn Street
COUNCIL DISTRICT(S): District 7, Super District 8 – Positions 1, 2, and 3
OWNER/APPLICANT: LC Wallace – Elmington Capital Group
REPRESENTATIVE: Owen Harris – Kimley-Horn Associates
REQUEST: Rezoning of +/-3.3 acres from Residential Urban – 1 (RU-1) to Mixed
Use (MU)
The following spoke in support: None
The following spoke in opposition: None
The Land Use Control Board reviewed the application and the staff report . A motion was made and
seconded to recommend approval of the application.
The motion passed by a unanimous vote of 9-0 on the consent agenda.
Respectfully,
Cc: Committee Members
File
2
PLOT PLAN
3
CONCEPT PLAN
4
EXAMPLE ARCHITECTURE DESIGN
ORDINANCE NO: ____________
ZONING ORDINANCE AMENDING ORDINANCE NO. 5367 OF CODE OF ORDINANCE, CITY
OF MEMPHIS, TENNESSEE, ADOPTED ON AUGUST 10, 2010, AS AMENDED, KNOWN AS
THE MEMPHIS AND SHELBY COUNTY UNIFIED DEVELOPMENT CODE, TO AUTHORIZE
A ZONING USE DISTRICT RECLASSIFICATION FOR LAND LOCATED ON THE WEST SIDE
OF SWINNEA ROAD +/ -2,645 FEET SOUTH OF HOLMES ROAD. BY TAKING THE LAND
OUT OF THE RESIDENTIAL URBAN – 1 (RU-1) USE DISTRICT AND INCLUDING IT IN THE
MIXED USE (MU) USE DISTRICT, KNOWN AS CASE NUMBER Z 2026-001
WHEREAS, a proposed amendment to the Memphis and Shelby County Unified Development
Code, being Ordinance No. 5367 of the Code of Ordinances, City of Memphis, Tennessee, as amended, has
been submitted to the Memphis and Shelby County Land Use Cont rol Board for its recommendation ,
designated as Case Number: Z 2026-001; and
WHEREAS, the Memphis and Shelby County Land Use Control Board has filed its
recommendation and the Division of Planning and Development has filed its report and recommendation
with the Council of the City of Memphis; and
WHEREAS, the Council of the City of Memphis has reviewed the aforementioned amendment
pursuant to Tennessee Code Annotated Section 13 -4-202(B)(2)(B)(iii) and has determined that said
amendment is consistent with the Memphis 3.0 General Plan; and
WHEREAS, the provisions of the Code of Ordinances, City of Memphis, Tennessee, as amended,
relating to the proposed amendment, have been complied with.
NOW THERE FORE, BE IT ORDAINED , BY THE COUNCIL OF THE CITY OF
MEMPHIS:
SECTION 1:
THAT, the Memphis and Shelby County Unified Development Code, Ordinance No. 5367 of the
Code of Ordinances, City of Memphis, as amended, be and the same hereby is amended with respect to Use
Districts, as follows:
BY TAKING THE FOLLOWING PROPERTY OUT OF THE Residential Urban – 1 (RU-1) USE
DISTRICT AND INCLUDING IT IN THE Mixed Use (MU) USE DISTRICT.
The following property located in the City of Memphis, Tennessee being more particularly described as
follows:
LEGAL DESCRIPTION
BEGINNING AT A POINT IN THE WEST LINE OF WOODLAWN STREET (60 FEET RIGHT OF
WAY), 85.11 FEET NORTH OF THE NORTH LINE OF CHELSEA AVENUE (80 FEET RIGHT OF
WAY), BEING IN THE NORTH LINE OF THE LARRY BLAND PROPERTY AS DESCRIBED IN
INSTRUMENT BH 1636, BEING THE NORTH LINE OF LOT 73, SNOWDEN AND BRINKLEY
SUBDIVISION AS RECORDED IN PLAT BOOK 3 PAGE 38; THENCE NORTH 09 DEGREES 23
MINUTES 26 SECONDS EAST ALONG THE WEST LINE OF WOODLAWN STREET A DISTANCE
OF 300.00 FEET TO THE SOUTH LINE OF THE MDM INVESTMENTS, LLC PROPERTY AS
DESCRIBED IN INSTRUMENT 21016675 AND BEING THE SOUTH LINE OF LOT 80, SNOWDEN
AND BRINKLEY SUBDIVISION; THENCE NORTH 80 DEGREES 08 MINUTES 55 SECONDS WEST
ALONG THE NORTH LINE OF LOT 79 AND LOT 58, SNOWDEN AND BRINKLEY SUBDIVISION,
A DISTANCE OF 400.04 FEET; THENCE SOUTH 09 DEGREES 20 MINUT ES 59 SECONDS WEST
ALONG THE EAST LINE OF TULLY STREET A DISTANCE OF 436.94 FEET TO THE NORTH LINE
OF THE MDM INVESTMENTS, LLC PROPERTY AS DESCRIBED IN INSTRUMENT 20103237;
THENCE SOUTH 80 DEGREES 18 MINUTES 58 SECONDS EAST A DISTANCE OF 100.00 FEET;
THENCE NORTH 09 DEGREES 20 MINUTES 59 SECONDS EAST A DISTANCE OF 36.20 FEET;
THENCE SOUTH 80 DEGREES 18 MINUTES 58 SECONDS EAST ALONG THE NORTH LINE OF
LOT 68 AND LOT 69, SNOWDEN AND BRINKLEY SUBDIVISION, A DISTANCE OF 100.00 FEET;
THENCE NORTH 09 DEGREES 20 MI NUTES 59 SECONDS EAST ALONG THE WEST LINE OF
LOT 70, SNOWDEN AND BRINKLEY SUBDIVISION, A DISTANCE OF 100.16 FEET; THENCE
SOUTH 80 DEGREES 08 MINUTES 54 SECONDS EAST ALONG THE NORTH LINE OF LOT 70
AND LOT 71, SNOWDEN AND BRINKLEY SUBDIVISION, A DISTANCE OF 99.82; THENCE
SOUTH 80 DEGREES 08 MINUTES 54 SECONDS EAST ALONG THE NORTH LINE OF LOT 72
AND LOT 73, SNOWDEN AND BRINKLEY SUBDIVISION, A DISTANCE OF 100.00 FEET TO THE
POINT OF BEGINNING, CONTAINING 143,686.31 SQUARE FEET / 3.30 ACRES MORE OR LESS.
SECTION 2:
THAT, the Zoning Administrator of the Division of Planning and Development be, and is hereby
directed to make the necessary changes in the Official Use District Maps to conform to the changes herein
made; that all official maps and records of the Memphis and Shelby County Land Use Control Board and
the City of Memphis be, and they hereby are, amended and changed so as to show the aforementioned
amendment of the said Zoning Ordinance.
SECTION 3:
THAT, this ordinance take effect from and after the date it shall have been passed by the Council,
signed by the Chairman of the Council, certified and delivered to the Office of the Mayor in writing by the
comptroller, and become effective as otherwise provided by law.
PLOT PLAN
CONCEPT PLAN
EXAMPLE ARCHITECTURE DESIGN
ATTEST:
CC: Division of Planning and Development
– Land Use and Development Services
– Office of Construction Enforcement
Shelby County Assessor
Staff Writer: Mahsan Ostadnia E-mail: mahsan.ostadnia@memphistn.gov
AGENDA ITEM: 13 L.U.C.B. MEETING: February 12, 2026
CASE NUMBER: Z 2026-001
LOCATION: Tully Street and Woodlawn Street
COUNCIL DISTRICT: District 7 and Super District 8
OWNER/APPLICANT: LC Wallace – Elmington Capital Group
REPRESENTATIVE: Owen Harris – Kimley-Horn Associates
REQUEST: Rezoning of +/-3.3 acres from Residential Urban – 1 (RU-1) to Mixed Use (MU)
CONCLUSIONS
1. The applicant proposes to rezone multiple parcels totaling approximately 3.30 acres located within the Brinkley and
Snowden Subdivision, currently zoned Residential Urban – 1 (RU -1). Based on Assessor records, most of the subject
parcels are vacant. The surrounding area is predominantly single-family residential, interspersed with vacant lots, and the
proposed rezoning area has frontage on two public streets, offering opportunities for improved access and site
organization.
2. The request seeks to extend the existing Mixed -Use zoning designation along Chelsea Avenue to include the subject
parcels, if approved, the applicant would end up 4.39 acres of land zoned MU enabling development of their proposed
multi-family residential p roject. The request seeks to extend the existing Mixed -Use zoning designation along Chelsea
Avenue to include the subject parcels, enabling development of a multi -family residential project. The proposed
development would introduce approximately 158 multi-family units, consisting of a mix of two, three, and four-bedroom
units, and would consolidate several underutilized parcels into a cohesive residential development. The current RU -1
zoning does not permit multi -family development at the proposed density, and the requested rezoning would provide
the necessary bulk and dimensional standards to accommodate the project. See page 10 for the concept plan.
3. Based on the conceptual site plan and applicable provisions of the Unified Development Code, the proposed development
generally meets the Contextual Infill standards related to bulk, form, and site organization. The proposal introduces multi-
family buildings at a scale and intensity anticipated within the Anchor Neighborhood – Mix of Building Types designation,
with building placement oriented toward public streets and internal circulation designed to limit impacts on adjacent
residential properties. The re quested rezoning would provide the bulk and dimensional standards necessary to
accommodate the proposed development. While final compliance with setbacks, building height, lot coverage,
landscaping, and parking placement will be evaluated during site plan review, the conceptual layout demonstrates
consistency with the UDC’s intent to ensure compatible massing, appropriate transitions, and cohesive infill development
within established neighborhoods.
4. The proposed rezoning is consistent with adopted planning policies, including Memphis 3.0 and the Uptown Community
Plan, which promote redevelopment of vacant and underutilized parcels, increased housing opportunities, and
reinforcement of neighborhood character near community anchors. The request aligns with the “Accelerate” Degree of
Change and the Anchor Neighborhood – Mix of Building Types designation by supporting residential infill and extending
mixed-use zoning along Chelsea Avenue. The proposal woul d facilitate reinvestment in a largely vacant area, improve
streetscape continuity, and support increased neighborhood activity while remaining compatible with surrounding
residential and mixed-use development patterns.
CONSISTENCY WITH MEMPHIS 3.0
This proposal is consistent with the Memphis 3.0 General Plan per the land use decision criteria. See further analysis on pages
18-21 of this report.
RECOMMENDATION:
Approval
Staff Report February 12, 2026
Z 2026-001 Page 2
2
LOCATION MAP
Subject property located within the pink circle.
SUBJECT PROPERTY
Staff Report February 12, 2026
Z 2026-001 Page 3
3
PUBLIC NOTICE VICINITY MAP
Subject property highlighted in yellow.
PUBLIC NOTICE DETAILS
In accordance with Sub-Section 9.3.4A of the Unified Development Code, a notice of public hearing is required
to be mailed and signage posted. A total of 203 notices were mailed on January 1 2, 2026, see page 22 of this
report for a copy of said notice. Additionally, two signs were posted at the subject property, see pages 23-24 of
this report for a copy of the sign affidavit.
NEIGHBORHOOD MEETING
The meeting was held at 5:00 PM on Monday, February 2, 2026, at Dave Well Community Center at 915 Chelsea
Avenue, Memphis, TN 38107. See pages 32-33 of this report for a copy of the neighborhood meeting summary.
Staff Report February 12, 2026
Z 2026-001 Page 4
4
AERIAL
Subject property outlined in yellow.
Staff Report February 12, 2026
Z 2026-001 Page 5
5
ZONING MAP
Subject property highlighted in yellow.
Staff Report February 12, 2026
Z 2026-001 Page 6
6
LAND USE MAP
Subject property indicated by a pink star.
Staff Report February 12, 2026
Z 2026-001 Page 7
7
SITE PHOTOS
View of subject property from Tully Street.
View of subject property from Woodlawn Street.
Staff Report February 12, 2026
Z 2026-001 Page 8
8
View of subject property from above.
View of subject property from above.
Staff Report February 12, 2026
Z 2026-001 Page 9
9
PLOT PLAN
Staff Report February 12, 2026
Z 2026-001 Page 10
10
CONCEPT PLAN
Staff Report February 12, 2026
Z 2026-001 Page 11
11
EXAMPLE ARCHITECTURE DESIGN
Staff Report February 12, 2026
Z 2026-001 Page 12
12
LEGAL DESCRIPTION
Staff Report February 12, 2026
Z 2026-001 Page 13
13
CASE REVIEW
Request
The request is a Rezoning of +/-3.3 acres from Residential Urban – 1 (RU-1) to Mixed Use (MU).
Review Criteria
Staff agrees the review criteria as set out in Sub-Section 9.5.7B of the Unified Development Code are met.
9.5.7B Review Criteria
In making recommendations, the Land Use Control Board shall consider the following matters:
9.5.7B(1) Consistency with any plans to be considered (see Chapter 1.9);
9.5.7B(2) Compatibility with the present zoning (including any residential corridor overlay district) and
conforming uses of nearby property and with the character of the neighborhood;
9.5.7B(3) Suitability of the subject property for uses permitted by the current versus the proposed district;
9.5.7B(4) Whether the proposed change tends to improve the balance of uses, or meets a specific demand
in the City or County; and
9.5.7B(5) The availability of adequate police services, fire services, school, road, park, wastewater
treatment, water supply and stormwater drainage facilities for the proposed zoning.
Site Details
Address:
Tully Street and Woodlawn Street
Parcel ID:
027004 00033, 027004 00034, 027004 00035, 027004 00036, 027004 00037, 027004 00038, 027004 00017C,
027004 00018C, 027004 00020, 027004 00021, 027004 00022, 027004 00023, 027004 00024
Area:
+/- 4.39 acres
Description:
The proposed parcels are known as part of Brinkley and Snowden Subdivision with a zoning of Residential Urban
– 1 (RU-1). Per the Assessor’s website, most of these lots are vacant. The proposed parcels for rezoning are 3.30
acres in total. The surrounding land uses are a mixture of single -family and vacant lots. Additionally, the
proposed area has two street frontages.
Analysis
The applicant proposes to rezone multiple parcels totaling approximately 3.30 acres located within the Brinkley
and Snowden Subdivision, currently zoned Residential Urban – 1 (RU-1). Based on Assessor records, most of the
subject parcels are vacant. The su rrounding area is predominantly single -family residential, interspersed with
vacant lots, and the proposed rezoning area has frontage on two public streets, offering opportunities for
improved access and site organization.
The request seeks to extend the existing Mixed -Use zoning designation along Chelsea Avenue to include the
subject parcels, if approved, the applicant would end up 4.39 acres of land zoned MU enabling development of
their proposed multi -family residential p roject. The request seeks to extend the existing Mixed -Use zoning
Staff Report February 12, 2026
Z 2026-001 Page 14
14
designation along Chelsea Avenue to include the subject parcels, enabling development of a multi -family
residential project. The proposed development would introduce approximately 158 multi -family units,
consisting of a mix of two, three, and four -bedroom units, and would consolidate several underutilized parcels
into a cohesive residential development. The current RU-1 zoning does not permit multi-family development at
the proposed density, and the requested rezoning would provide the necessary bulk and dimensional standards
to accommodate the project. See page 10 for the concept plan.
Based on the conceptual site plan and applicable provisions of the Unified Development Code, the proposed
development generally meets the Contextual Infill standards related to bulk, form, and site organization. The
proposal introduces multi-family buildings at a scale and intensity anticipated within the Anchor Neighborhood
– Mix of Building Types designation, with building placement oriented toward public streets and internal
circulation designed to limit impacts on adjacent residential properties. The re quested rezoning would provide
the bulk and dimensional standards necessary to accommodate the proposed development. While final
compliance with setbacks, building height, lot coverage, landscaping, and parking placement will be evaluated
during site plan review, the conceptual layout demonstrates consistency with the UDC’s intent to ensure
compatible massing, appropriate transitions, and cohesive infill development within established
neighborhoods.
The proposed rezoning is consistent with adopted planning policies, including Memphis 3.0 and the Uptown
Community Plan, which promote redevelopment of vacant and underutilized parcels, increased housing
opportunities, and reinforcement of neighborhood character near community anchors. The request aligns with
the “Accelerate” Degree of Change and the Anchor Neighborhood – Mix of Building Types designation by
supporting residential infill and extending mixed-use zoning along Chelsea Avenue. The proposal would facilitate
reinvestment in a largely vacant area, improve streetscape continuity, and support increased neighborhood
activity while remaining compatible with surrounding residential and mixed-use development patterns.
RECOMMENDATION
Staff recommends approval.
Staff Report February 12, 2026
Z 2026-001 Page 15
15
DEPARTMENTAL COMMENTS
The following comments were provided by agencies to which this application was referred:
City Engineer: See page 16.
County Engineer: No comments received.
City Fire Division: See page 17.
County Fire Division: No comments received.
City Real Estate: No comments received.
County Health Department: No comments received.
Shelby County Schools: No comments received.
Construction Code Enforcement: No comments received.
Memphis Light, Gas and Water: No comments received.
Office of Sustainability and Resilience: No comments received.
Office of Comprehensive Planning: See pages 18-21.
Staff Report February 12, 2026
Z 2026-001 Page 16
16
City Engineer:
1. Standard Public Improvement Contract or Right -Of-Way Permit as required in Section 5.5.5 of the Unified
Development Code.
Sewers:
2. The availability of City sanitary sewer is unknown at this time. Once the developer has submitted proposed
sewer discharge rates to the City’s Sewer Design Dept, a determination can be made as to available sewer
capacity.
Roads:
3. The Developer shall be responsible for the repair and/or replacement of all existing curb and gutter along
the frontage of this site as necessary.
4. All existing sidewalks and curb openings along the frontage of this site shall be inspected for ADA
compliance. The developer shall be responsible for any reconstruction or repair necessary to meet City
standards.
Traffic Control Provisions:
5. The developer shall provide a traffic control plan to the city engineer that shows the phasing for each street
frontage during demolition and construction of curb gutter and sidewalk. Upon completion of sidewalk and
curb and gutter improvements, a minimum 5 foot wide pedestrian pathway shall be provided throughout
the remainder of the project. In the event that the existing right of way width does not allow for a 5 -foot
clear pedestrian path, an exception may be considered.
6. Any closure of the right of way shall be time limited to the active demolition and construction of sidewalks
and curb and gutter. Continuous unwarranted closure of the right of way shall not be allowed for the
duration of the project. The developer shall provide on the traffic control plan, the time needed per phase
to complete that portion of the work. Time limits will begin on the day of closure and will be monitored by
the Engineering construction inspectors on the job.
7. The developer’s engineer shall submit a Trip Generation Report that documents the proposed land use,
scope and anticipated traffic demand associated with the proposed development. A detailed Traffic Impact
Study will be required when the accepted Trip Generation Report indicates that the number for projected
trips meets or exceeds the criteria listed in Section 210 -Traffic Impact Policy for Land Development of the
City of Memphis Division of Engineering Design and Policy Review Manual. Any required Traffic Impact Study
will need to be formally approved by the City of Memphis, Traffic Engineering Department.
Curb Cuts/Access:
8. The City Engineer shall approve the design, number, and location of curb cuts.
9. Any existing nonconforming curb cuts shall be modified to meet current City Standards or closed with curb,
gutter, and sidewalk.
10. Will require engineering ASPR.
Staff Report February 12, 2026
Z 2026-001 Page 17
17
City Fire Division:
1. All design and construction shall comply with the 2021 edition of the International Fire Code with local
amendments and referenced standards.
2. Fire apparatus access shall comply with section 503.
3. Where security gates are installed that affect required fire apparatus access roads, they shall comply
with section 503.6.
4. Fire protection water supplies (including fire hydrants) shall comply with section 507.
5. Where fire apparatus access roads or a water supply for fire protection are required to be installed, such
protection shall be installed and made serviceable prior to and during the time of construction except
when approved alternate methods of protection are provided.
6. IFC 510 In-building two-way emergency responder communication coverage shall be provided in all new
and existing buildings. Buildings and structures that cannot support the required level of coverage shall
be equipped with systems and components to enhance signals and achieve the required level of
communication coverage.
7. A detailed plans review will be conducted by the Memphis Fire Prevention Bureau upon receipt of
complete construction documents. Plans shall be submitted to the Shelby County Office of Code
Enforcement.
Staff Report February 12, 2026
Z 2026-001 Page 18
18
Office of Comprehensive Planning:
This summary is being produced in response to the following application to support the Land Use and
Development Services department in their recommendation: Z 2026-001
Site Address/Location: 896 Tully.
The site includes 22 parcels bounded by Woodlawn to the East, Chelsea to the South, and Thomas to the West.
The northern boundary is with parcels 027004 00040 and 027004 00016.
Overlay District/Historic District/Flood Zone: Not in an Overlay District, Historic District, or Flood Zone
Future Land Use Designation: Anchor Neighborhood-Mix of Building Types (AN-M)
Street Type: Avenue, Local Neighborhood Streets
Applicant is seeking a Rezoning to expand the MU district along Chelsea to include parcels further along Tully
and Woodlawn for a large Multi-Family development.
The following information about the land use designation can be found on pages 76 – 122:
1. Future Land Use Planning Map
Red polygon indicates the application site on the Future Land Use Map.
2. Land Use Description/Intent
Anchor Neighborhood -Mix of Building Types (AN -M) are walkable
neighborhoods within a 5 – 10-minute walk of a Community Anchor. These
neighborhoods are made up of a mix of single -unit and multi -unit housing.
Graphic portrayal of AN-M is to the right.
Staff Report February 12, 2026
Z 2026-001 Page 19
19
“AN-M” Form & Location Characteristics
ACCELERATE: Primarily detached, single-family house-scale residences of 1-3 stories in height. Attached, house-
scale single-family, duplexes, triplexes and quadplexes of 1 -3 stories in height permitted on parcels within 200
feet of an anchor and at inters ections where the presence of such housing type currently exists. Building -scale
large homes and apartments of 2 -4 stories in height permitted on parcels within 100 feet of an anchor; at
intersections where the presence of such housing type currently exist s at the intersection. Other housing and
commercial types along avenues, boulevards and parkways as identified in the Street Types Map where same
types exist on one or more adjacent parcels.
“AN-M” Zoning Notes
Generally compatible with the following zone districts: RU -2, RU-3, RU-4, R-SD, R-R, MDR, and CMU -1 when
located along avenues, boulevards, and parkways as identified in the Street Types Map, in accordance with Form
and characteristics listed above.
Existing, Adjacent Land Use and Zoning
Existing Land Use and Zoning: Vacant, Multi-family; RU-1, MU.
Adjacent Land Use and Zoning: Single-Family, Multi-Family, Institutional, Commercial, Office; RU-1, MU.
Overall Compatibility: This requested use is compatible with the land use description/intent, form & location
characteristics, the zoning notes, and existing/adjacent land use and zoning. Expanding access to housing is
consistent with accelerating the activity at the nearby Chelsea and Thomas anchor.
3. Degree of Change Map
Red polygon denotes the proposed site in Degree of Change area. Degree of Change is Accelerate.
Staff Report February 12, 2026
Z 2026-001 Page 20
20
4. Degree of Change Description
Accelerate areas rely on a mix of primarily private and philanthropic resources along with some public resources
to intensify the existing pattern of a place.
The proposed building is a private investment and infill development that supports the anchor neighborhood.
Pages 65 – 67.
5. Objectives/Actions Consistent with Goal 1, Complete, Cohesive, Communities
The proposed development is consistent with Objective 1.1 – Focus future growth and density in and around
Community and Citywide Anchors Action 1.1.30 – Incentivise housing and employment growth to occur
arounding Citywide and Community Anchors and high frequency transit corridors, preserving and integrating
existing affordable housing where possible.
The development increases housing choice and density to support the Chelsea and Thomas anchor along
MATA’s Bus Route 8.
6. Pertinent Sections of Memphis 3.0 that Address Land Use Recommendations
The development is consistent with Objective 1.3 – Develop strategies that reduce blight and vacancy Action
1.3.7 – Focus redevelopment efforts for vacant parcels within one -quarter mile of anchors (anchor
neighborhoods).
The existing property is mostly vacant land directly adjacent to the Chelsea and Thomas anchor. Development
of these properties into more housing will support any future activity at this anchor.
Consistency Analysis Summary
Applicant is seeking a Rezoning to expand the MU district along Chelsea to include parcels further along Tully
and Woodlawn for a large Multi-Family development.
This requested use is compatible with the land use description/intent, form & location characteristics, the zoning
notes, and existing/adjacent land use and zoning. Expanding access to housing is consistent with accelerating
the activity at the nearby Chelsea and Thomas anchor.
The proposed building is a private investment and infill development that supports the anchor neighborhood.
Pages 65 – 67.
The proposed development is consistent with Objective 1.1 – Focus future growth and density in and around
Community and Citywide Anchors Action 1.1.30 – Incentivise housing and employment growth to occur
arounding Citywide and Community Anchors and high frequency transit corridors, preserving and integrating
existing affordable housing where possible.
The development is consistent with Objective 1.3 – Develop strategies that reduce blight and vacancy Action
1.3.7 – Focus redevelopment efforts for vacant parcels within one -quarter mile of anchors (anchor
neighborhoods).
Additional Comments
While the development is consistent, we recommend any effort to reduce parking should be made as over 2
acres of surface parking in an Anchor Neighborhood is not consistent with supporting neighborhood
walkability/connectivity.
Reducing parking amount/requirements is consistent with Objective 4.2 – Promote safe movement of people
and vehicles across all modes of travel Action 4.2.2 – Prioritize pedestrian and bicycle improvements within
Staff Report February 12, 2026
Z 2026-001 Page 21
21
anchors and anchor neighborhoods, starting with accelerate anchors. The inclusion of 1.39 spaces per unit
assumes each unit will have access to a vehicle. Increasing vehicle access will directly reduce transit ridership,
which is inconsistent with the Anchor strategy. The development’s increase in density should focus more
support towards transit routes along the Chelsea corridor.
Based on the information provided, the proposal is CONSISTENT with the Memphis 3.0 Comprehensive Plan.
Staff Report February 12, 2026
Z 2026-001 Page 22
22
MAILED PUBLIC NOTICE
Staff Report February 12, 2026
Z 2026-001 Page 23
23
SIGN AFFIDAVIT
Staff Report February 12, 2026
Z 2026-001 Page 24
24
Staff Report February 12, 2026
Z 2026-001 Page 25
25
PROJECT MEMORANDUM
Staff Report February 12, 2026
Z 2026-001 Page 26
26
Staff Report February 12, 2026
Z 2026-001 Page 27
27
Staff Report February 12, 2026
Z 2026-001 Page 28
28
Staff Report February 12, 2026
Z 2026-001 Page 29
29
Staff Report February 12, 2026
Z 2026-001 Page 30
30
Staff Report February 12, 2026
Z 2026-001 Page 31
31
Staff Report February 12, 2026
Z 2026-001 Page 32
32
NEIGHBORHOOD MEETING SUMMARY
Staff Report February 12, 2026
Z 2026-001 Page 33
33
Staff Report February 12, 2026
Z 2026-001 Page 34
34
APPLICATION
Staff Report February 12, 2026
Z 2026-001 Page 35
35
Staff Report February 12, 2026
Z 2026-001 Page 36
36
Staff Report February 12, 2026
Z 2026-001 Page 37
37
Staff Report February 12, 2026
Z 2026-001 Page 38
38
Staff Report February 12, 2026
Z 2026-001 Page 39
39
Staff Report February 12, 2026
Z 2026-001 Page 40
40
OWNER AFFIDAVIT
Staff Report February 12, 2026
Z 2026-001 Page 41
41
Staff Report February 12, 2026
Z 2026-001 Page 42
42
Staff Report February 12, 2026
Z 2026-001 Page 43
43
Staff Report February 12, 2026
Z 2026-001 Page 44
44
LETTER OF INTENT
Staff Report February 12, 2026
Z 2026-001 Page 45
45
LETTERS RECEIVED
No letters received at the time of completion of this report.
East Service Center: 6465 Mullins Station Rd; Memphis,
Tennessee
38134
Downtown Service Center: 125 N. Main Street;
Memphis, T
ennessee 38103
website: www.develop901.com
Memphis and Shelby County Division of
Planning and Development
Record Summary for Rezoning
Record Detail Information
Record T
ype: Rezoning Record Status: Pending
Opened Date:
January 2, 2026
Record Number: Z 2026-001
Record Name: Chelsea Avenue Project
Expiration Date:
Description of Work: This application requests that thirteen Residential Urban (RU-1) parcels be rezoned to
Mixed-Use (MU). The rezoning of these parcels will allow for a high-quality residential development
along the Chelsea Avenue corridor in the Uptown Neighborhood.
Parent Record Number:
Address:
896 TULLY
ST, MEMPHIS 38107
Owner Information
Primary Owner Name
Owner Address Owner Phone
Y DAVIS KARLEN
AND DICKERSON WELLS AND
5100 POPLAR AVE, MEMPHIS, TN 38137
Parcel Information
027004 00035
Data Fields
PREAPPLICA
TION MEETING
Name of DPD Planner Jeffrey Penzes
Date of Meeting 12/04/2025
Pre-
application Meeting Type In Person
GENERAL INFORMATION
Have you held a neighborhood meeting? No
Is this application in response to a citation from
Construction Code Enforcement or Zoning
Letter?
No
Page 1 of 4 Z 2026-001
GENERAL INFORMATION
If yes, please provide additional information -
GIS INFORMATION
Case Layer Z88-157, Z88-157
Central Business Improvement District No
Class R
Downtown Fire District No
Historic District -
Land Use VACANT
Municipality MEMPHIS
Overlay/Special Purpose District -
Zoning MU
State Route -
Lot 62-64
Subdivision BRINKLEY
& SNOWDEN S/D
Planned Development District -
Wellhead Protection Overlay District Yes
County Commission District -
City Council District -
City Council Super District -
Data Tables
ADDRESS
AND PARCEL
LIST
Property Address: 874 TULLY ST
Property Parcel Number: 027004 00033
Property Address: 880 TULLY ST
Property Parcel Number: 027004 00034
Property Address: 894 TULLY
Property Parcel Number: 027004 00035
Property Address: 902 TULLY ST
Property Parcel Number: 027004 00036
Property Address: 906 TULLY ST
Property Parcel Number: 027004 00037
Property Address: 910 TULLY ST
Property Parcel Number: 027004 00038
Property Address: 916 N TULLY ST
Property Parcel Number: 027004 00017C
Property Address: 915 WOODLAWN
Property Parcel Number: 027004 00018C
Page 2 of 4 Z 2026-001
Property Address: 909 WOODLAWN ST
Property Parcel Number: 027004 00020
Property
Address: 905 WOODLAWN ST
Property Parcel Number: 027004 00021
Property Address: 899 WOODLAWN ST
Property Parcel Number: 027004 00022
Property Address: 897 WOODLAWN
Property Parcel Number: 027004 00023
Property Address: 889 WOODLAWN
Property Parcel Number: 027004 00024
Contact Information
LC WALLACE
-
APPLICANT
Name
Address
Phone
Contact Type
OWEN HARRIS
(901)245-4482
ARCHITECT / ENGINEER /
SURVEYOR
Name
Address
Phone
Contact Type
OWEN HARRIS
(901)245-4482
REPRESENTATIVE
Name
Address
Phone
Contact Type
Fee Information
Date
AssessedBalanceStatusFeesQuantityFee ItemInvoice #
01/02/20260.00INVOICED1,000.001Non-Residential Rezoning
- 5 acres or less
1699113
01/02/20260.00INVOICED26.001Credit Card Use Fee (.026
x fee)
16991
13
Total Fee Invoiced: $1,026.00 Total Balance: $0.00
Payment Information
Payment
Amount Method of Payment
Credit Card$1,026.00
Page 3 of 4 Z 2026-001
Page 4 of 4 Z 2026-001
Revised 10.09.2023 1
City Hall – 125 N. Main Street, Suite 468 – Memphis, Tennessee 38103 – (901) 636-6619
LAND USE CONTROL BOARD REZONING APPLICATION
TO FILE ONLINE USE THE DEVELOP 901 CITIZEN PORTAL
Date: Prev ious Case/Docket #:
PLEASE TYPE OR PRINT
Property Owner of Record: Phon e #:
Mailing Address: City/State: Zip:
Property Owner Email Address:
Applicant: Phone #:
Mailing Address: City/State: Zip:
Applicant Email Address:
Representative: Phone #:
Mailing Address: City/State: Zip:
Representative Email Address:
Architect/Engineer/Surveyor: Phone #:
Mailing Address: City/State: Zip:
Architect/Engineer/Surveyor Email Address:
PREMISES LOCATION (Describe by street address & directional location description, e.g. 200 Johnson Street, North side
of Johnson Street, 100 feet east of Brown Street):
Parcel ID:
Project Name:
Project Description:
Did you have a pre-application meeting with the Division of Planning and Development (DPD)?
Planner: Date of Meeting:
Revised 10.09.2023 2
Area A Area B Area C
Acres: _______________ _______________ _______________
Existing Zoning: _______________ _______________ _______________
Existing Use of Property: _______________ _______________ _______________
Requested Use of Property: _______________ _______________ _______________
Requested Zoning: _______________ _______________ _______________
Is this application in response to a citation, stop work order, or zoning letter? (y es or no)
If yes, please provide a copy of the citation, stop work order, and/or zoning letter along with any other relevant
information:
REVIEW CRITERIA (UDC Sub-Section 9.5.7B)
In making recommendations, the Land Use Control Board shall consider the following matters:
1) Consistency with any plans to be considered (see Chapter 1.9):
2) Compatibility with the present zoning (including any residential corridor overlay district) and conforming uses of
nearby property and with the character of the neighborhood:
3) Suitability of the subject property for uses permitted by the current versus the proposed district:
4) Whether the proposed change tends to improve the balance of uses, or meets a specific demand in the City or
County:
Revised 10.09.2023 3
5) The availability of adequate police services, fire services, school, road, park, wastewater treatment, water supply
and stormwater drainage facilities for the proposed zoning:
LAND USE CONTROL BOARD REZONING APPLICATION GUIDE
To file online use the Develop 901 Citizen Portal: www.aca-prod.accela.com/SHELBYCO/Default
GENERAL INFORMATION
UNIFIED DEVELOPMENT CODE (UDC) REFERENCES FOR REZONINGS:
a) Zoning Change – UDC Chapter 9.5
PRE-APPLICATION MEETING – This is a meeting in which the Division of Planning and Development Land Use and
Development Services discusses the procedures, standards, and regulations required of a request in accordance with the
Unified Development Code with the applicant(s) and/or their representative(s), see Section 9.3.1 of Unified Development
Code for additional information. To schedule a pre-applicatio n meeting please call Land Use and Development Services at
(901) 636-6619.
APPL
ICATION REVIEW PROCESS – Click here to view a flowchart that explains the review process by application type, as
well as the expected review time for each.
NEIG
HBOORHOOD MEETING – At least ten (10) days, but not more than one hundred twenty (120) days, prior to a hearing
before the Land Use Control Board, the applicant shall provide an opportunity to discuss the proposal with representatives
from neighborhoods adjacent to the development site, see Section 9.3.2 of the Unified Development Code for additional
information, procedures, standards, and requirements.
APPL
ICATION DEADLINES – A link to the Applications Deadlines Calendar can be found on the Land Use and Development
Services’ webpage.
APPLICATION ASSISTANCE – Click here to view a list
of firms and individuals who frequently provide assistance with the
filing of applications with the Division of Planning and Development.
FILI
NG FEE(S) – See the Fee Schedule. Make checks payable to “M/SC Division of Planning and Development”
POSTED NOTICE – Posting sign(s) may be required ; refer to Sub-Sections 9.3.4A and 9.3.4C of the Unified Development
Code for specific requirements. If posted notice is required, the sign affidavit and a photograph of each sign on the subject
property are also mandatory. Download templates of the sign in a PowerPoint document. Click here for a list of companies
that may be able to produce posted notice signs.
ZONING CHANGE REQUIREMENTS
A rezoning must meet the following requirements of Section 9.5.2 of the UDC:
A. A zoning change shall correspond with the boundary lines of existing tracts and lots, and with the centerline of any
abutting streets or alleys. Where the boundaries of a zoning change request stop short of an exterior property line,
it must be possible to subdivide and develop that portion of the property outside the proposed zoning change
boundary in accordance with the existing zoning and other requirements of this development code.
B. All zoning requirements shall be met within the boundaries of the area being rezoned. If all of the requirements
Revised 10.09.2023 4
cannot be met on the site being rezoned, the zoning change shall be expanded to include all property necessary to
meet zoning requirements.
C. Any zoning change affecting property within a community redevelopment area shall be supported by the
Community Redevelopment Plan for that area.
REQUIRED DOCUMENTS
As part of the application, the following documents are required to be submitted:
LETTER OF INTENT – A brief narrative statement generally describing the nature, location, and extent of the development
and the market it is intended to serve.
PLOT PLAN – In general, a drawing of the subject property drawn to an engineering scale, showing property boundary
lines and dimensions, existing utilities and easements, roadways, rail lines and public rights-of-way, crossing and adjacent
to the subject property; etc.
LEGAL DESCRIPTION IN WORD – A land description legally sufficient in the matter of locatability that identifies a particular
locatable area or areas to which the interest conveyed attaches . It should contain title identity, not interfere with the
senior rights of others, be so written that either at the present or at a future date, a competent surveyor can readily locate
it, not contain words capable of alternate interpretations, contain measurement data sufficient to describe a geometric
area that closes mathematically, and be based on a recent survey.
VICINITY MAP – Map showing the subject property (boldly outlined) and all adjacent parcel owners. Refer to Sub-Section
9.3.4A of the Unified Development Code for specific notification requirements. Public Notice Tool User Guide.
MAILING LABELS OF NAMES AND ADDRESSES – A complete list of names and mailing addresses, of all property owners
shown on the vici nity map, typewritten, and formatted as 1" x 2 5/8" labels (Avery 5160). Additionally, include the
application property owner of record, applicant, representative, and/or Architect/Engineer/Surveyor. Public Notice Tool
User Guide.
DEED(S) – Most recent deed(s) on file with Shelby County Register of Deeds.
OWNER AFFIDAVIT – Affidavit of ownership or owner designee.
Additional documents may be required prior to approval.
kimley-horn.com 6750 Poplar Avenue, Suite 600, Memphis, Tennessee 38138 901-374-9109
January 02, 2025
Mr. Jeffrey Penzes and Ms. Mahsan Ostadnia
Land Use and Development Services
Division of Planning and Development
125 N. Main, Ste. 468
Memphis, Tennessee 38103
RE: Rezoning Application - Chelsea Avenue Project
Mr. Penzes and Ms. Ostadnia:
On behalf of the Developer, Elmington Capital Group , we are pleased to submit the enclosed rezoning
application. The thirteen subject parcels in this rezoning application total 3.30 acres and are located along Tully
and Woodlawn Streets. Additionally, the subject parcels will be part of a total project area for a multi -family
development (inclusive of the thirteen within this rezoning application) for a total of 4.39 acres and includes
frontage along Chelsea Avenue.
This rezoning application is requesting that the current M ixed-Use (MU) zoning designation located along
Chelsea Avenue be expanded to include the subject parcels. In collaboration with Elmington Capital Group, the
proposed total project area of 4.39 acres has been conceptually designed as an approximate ly 158-unit multi-
family development. The conceptual plan consists of a mix of 2-, 3-, and 4-bedroom units, leasing office, resident
amenity areas, and ancillary parking. The rezoning of the subject parcels will provide the necessary bulk
regulations to support multi-family development while providing improved streetscapes, buildings that front
adjacent streets, and concealed parking areas.
Please find enclosed the required rezoning application documents, as well as additional support documents. We
are confident that the Division of Planning and Development staff, Land Use Control Board members and City
Council members will find that the rezoning application and proposed multi-family development rises to the
City’s standards and will be a benefit to the community. Elmington Capital Group has successfully delivered
quality development throughout Memphis including Tillman Cove, Uptown Flats, 2nd Street Flats, Burkle & Main,
Forum Flats and Patterson Flats and intends to implement the same high level of quality with this proposed
development.
On behalf of the applicant, thank you for your assistance and consideration of this request; we look forward to
working with you. If we can answer any questions or be of assistance, please do not hesitate to contact me.
Sincerely,
Kimley-Horn & Associates, Inc.
Owen Harris, PLA, ASLA
CHELSEA AVENUE
TULLY STREET
WOODLAWN STREET
LARRY BLANDINST. BH 1636ZONED M-U
INFINITY REALESTATE AND
DEVELOPMENT LLC
INST. 20090261
ZONED M-U
MDM INVESTMENTS OFMEMPHIS LLC, ISAOA
INST. 20103236
ZONED M-U
-66- -67-
-68- -69-
-70- -71-
-72-
-73-
-74-
-65-
-64-
-63-
-62-
-61-
-60-
-59-
-58-
MDM INVESTMENTS OFMEMPHIS LLC, ISAOA
INST. 20103236
ZONED M-U
MDM INVESTMENTS OF
MEMPHIS LLCINST. 21093104
ZONED M-U
MDM INVESTMENTS OFMEMPHIS LLC, ISAOA
INST. 20103237
ZONED M-U
MDM INVESTMENTS OF
MEMPHIS LLC, ISAOA
INST. 20103237
ZONED M-U
MDM INVESTMENTS OF
MEMPHIS LLC, ISAOA
INST. 20103237
ZONED M-U
MDM INVESTMENTS OF
MEMPHIS, LLC
INST. 21093097
ZONED RU-1
MDM INVESTMENTS OF
MEMPHIS, LLC
INST. 21093098
ZONED RU-1
MDM INVESTMENTS OF
MEMPHIS, LLC
INST. 21093099
ZONED RU-1
MDM INVESTMENTS OF
MEMPHIS, LLC
INST. 22090622
ZONED RU-1
SOUTH CITY MEMPHIS LLC
INST. 21027145
ZONED RU-1
MICHAEL MCGHEE
INST. 22125049
ZONED RU-1
SNOWBALL 221 LP
INST. 16068208
ZONED RU-1
-57-
MDM INVESTMENTS OF
MEMPHIS, LLC
INST. 20122637
ZONED RU-1
-75-
-76-
-77-
-78-
-79-
-80-
MDM INVESTMENTS OF
MEMPHIS LLC, ISAOA
INST. 20103232
ZONED RU-1
MDM INVESTMENTS OF
MEMPHIS LLC
INST. 21016675
ZONED RU-1
TRINETTE JACKSON
INST. 12034578
ZONED RU-1
MICHAEL MCGHEE
INST. 23043339
ZONED RU-1
MDM INVESTMENTS OF
MEMPHIS LLC, ISAOA
INST. 20103229
ZONED RU-1
MDM INVESTMENTS OF
MEMPHIS, LLC
INST. 21016675
ZONED RU-1
L- 31.72
R- 15.00 D-121°09'32"
CB- S 51°13'47" E
CH- 26.13
E
E
E
80' RIGHT-OF-WAY PUBLIC
60' RIGHT-OF-WAY PUBLIC
60' RIGHT-OF-WAY PUBLIC
10.5
E
EX. SIGN
MICHAEL MCGHEE
INST. 22019127
ZONED RU-1
S80°08'54"E 100.00'S80°08'54"E 99.82'
N9°20'59"E
100.16'
S80°18'58"E 100.00'
N9°20'59"E
36.20'
S80°18'58"E 100.00'
S9°20'59"W
436.94'
N80°08'55"W 400.04'
N9°23'26"E
300.00'
AREA OF REZONING
3.30 ACRES
143,686.31 S.F.
0
December 22, 2025
NORTH
20 40 80 120
CHELSEA AVENUE PROJECT
PLOT PLAN
PLOT PLAN LEGEND
AREA OF REZONING BOUNDARY
ADJACENT PARCEL LINES
PARCEL LINES WITHIN AREA OF REZONING
PROJECT AREA
CHELSEA AVENUECHELSEA AVENUE
CHELSEA
Chelsea Avenue at Tully Street
Municipality: Memphis Tennessee
PRELIMINARY YIELD STUDY
CONCEPT B
0’0’ 15’15’ 30’30’
SCALE: 1”=30’SCALE: 1”=30’
60’60’
N
BUILDING 1
4 Story Corridor
+/- 54 Units
BUILDING 2
4 Story Corridor
+/- 64 Units
BUILDING 3
4 Story Corridor
+/- 40 Units
STREET PARKINGSTREET PARKING
CLUBHOUSE/LEASING
TRASH COLLECTION
STORM UNDERGROUND
DEVELOPMENT SUMMARY
4.0 Acres
158 Multi-Family Units
+/- 39.5 units/acre
Parking Provided:
193 Surface Spaces
26 Str
eet Spaces
1.39 per unit
This plan depicts a
preliminary layout for
site zoning purposes.
Final layout may vary
to accommodate site
conditions.
PROPOSED UNIT MIX
TOTAL:
158
2 Bedroom: 36
3 Bedroom: 90
4 Bedroom: 32
TULLY STREETTULLY STREET WOODLAWN STREETWOODLAWN STREET
CHELSEA AVENUE
PROJECT
MEMPHIS, TENNESSEE
CONCEPT DESIGN
4.39 Acres
158 Multi-Family Units
Example Architecture
12/30/2025
Chelsea Avenue
Page 2
kimley-horn.com 6750 Poplar Avenue, Suite 600, Memphis, TN 38138 901 374 9109
Figure 1: Vicinity Map
Site
North
CHELSEA AVENUE
TULLY STREET
WOODLAWN STREET
LARRY BLANDINST. BH 1636ZONED M-U
INFINITY REALESTATE AND
DEVELOPMENT LLC
INST. 20090261
ZONED M-U
MDM INVESTMENTS OFMEMPHIS LLC, ISAOA
INST. 20103236
ZONED M-U
-66- -67-
-68- -69-
-70- -71-
-72-
-73-
-74-
-65-
-64-
-63-
-62-
-61-
-60-
-59-
-58-
MDM INVESTMENTS OFMEMPHIS LLC, ISAOA
INST. 20103236
ZONED M-U
MDM INVESTMENTS OF
MEMPHIS LLCINST. 21093104
ZONED M-U
MDM INVESTMENTS OFMEMPHIS LLC, ISAOA
INST. 20103237
ZONED M-U
MDM INVESTMENTS OF
MEMPHIS LLC, ISAOA
INST. 20103237
ZONED M-U
MDM INVESTMENTS OF
MEMPHIS LLC, ISAOA
INST. 20103237
ZONED M-U
MDM INVESTMENTS OF
MEMPHIS, LLC
INST. 21093097
ZONED RU-1
MDM INVESTMENTS OF
MEMPHIS, LLC
INST. 21093098
ZONED RU-1
MDM INVESTMENTS OF
MEMPHIS, LLC
INST. 21093099
ZONED RU-1
MDM INVESTMENTS OF
MEMPHIS, LLC
INST. 22090622
ZONED RU-1
SOUTH CITY MEMPHIS LLC
INST. 21027145
ZONED RU-1
MICHAEL MCGHEE
INST. 22125049
ZONED RU-1
SNOWBALL 221 LP
INST. 16068208
ZONED RU-1
-57-
MDM INVESTMENTS OF
MEMPHIS, LLC
INST. 20122637
ZONED RU-1
-75-
-76-
-77-
-78-
-79-
-80-
MDM INVESTMENTS OF
MEMPHIS LLC, ISAOA
INST. 20103232
ZONED RU-1
MDM INVESTMENTS OF
MEMPHIS LLC
INST. 21016675
ZONED RU-1
TRINETTE JACKSON
INST. 12034578
ZONED RU-1
MICHAEL MCGHEE
INST. 23043339
ZONED RU-1
MDM INVESTMENTS OF
MEMPHIS LLC, ISAOA
INST. 20103229
ZONED RU-1
MDM INVESTMENTS OF
MEMPHIS, LLC
INST. 21016675
ZONED RU-1
L- 31.72
R- 15.00 D-121°09'32"
CB- S 51°13'47" E
CH- 26.13
E
E
E
80' RIGHT-OF-WAY PUBLIC
60' RIGHT-OF-WAY PUBLIC
60' RIGHT-OF-WAY PUBLIC
10.5
E
EX. SIGN
MICHAEL MCGHEE
INST. 22019127
ZONED RU-1
S80°08'54"E 100.00'S80°08'54"E 99.82'
N9°20'59"E
100.16'
S80°18'58"E 100.00'
N9°20'59"E
36.20'
S80°18'58"E 100.00'
S9°20'59"W
436.94'
N80°08'55"W 400.04'
N9°23'26"E
300.00'
AREA OF REZONING
3.30 ACRES
143,686.31 S.F.
PLOT PLAN LEGEND
AREA OF REZONING BOUNDARY
ADJACENT PARCEL LINES
PARCEL LINES WITHIN AREA OF REZONING
PROJECT AREA
NORTH
Page 3
kimley-horn.com 6750 Poplar Avenue, Suite 600, Memphis, TN 38138 901 374 9109
Figure 2: Preliminary Site Plan
Page 4
kimley-horn.com 6750 Poplar Avenue, Suite 600, Memphis, TN 38138 901 374 9109
TRIP GENERATION
Land Use Category 221 Multifamily Housing (Mid-Rise) was used to estimate the number of trips
generated as a part of the proposed development for the proposed multifamily housing (mid-rise) land
use. Traffic generated by the proposed development will access the site via one full-access driveway
along Tully Street and one full-access driveway along Woodlawn Street.
Based on the site layout and location of the proposed access points, it is assumed that approximately
50% of trips generated by the site will enter/exit via Tully Street and 50% will enter/exit via Woodlawn
Street. All trips generated by the proposed development are expected to enter/exit the site via
Chelsea Avenue. A summary of the estimated trip generation for the proposed development can be
found in Table 1.
Table 1: Trip Generation Summary Table
ADJACENT ROAD INFORMATION
The subject development has frontage along Chelsea Avenue but does not provide access along
Chelsea Avenue. Based on TDOT historical traffic data, Chelsea Avenue had an AADT of
approximately 5,807 vehicles in 2025. The TDOT traffic data for Chelsea Avenue is provided in
Figure 3.
(Intentionally Left Blank)
Daily Trips
Total Total In Out Total In Out
221 Multifamily Housing (Mid-Rise) 158 D.U. 705 59 14 45 60 38 22
705 59 14 45 60 38 22
PM Peak Hour TripsITE
Code Land Use Type Intensity
AM Peak Hour Trips
Trip Generation Table
Total Proposed External Site Trips
Page 5
kimley-horn.com 6750 Poplar Avenue, Suite 600, Memphis, TN 38138 901 374 9109
Figure 3: Chelsea Avenue TDOT Traffic History
Page 6
kimley-horn.com 6750 Poplar Avenue, Suite 600, Memphis, TN 38138 901 374 9109
EVALUATION
The first, second, third, fourth, and fifth criteria included in the City of Memphis Engineering Design
Review and Policy Manual for determining if a traffic impact study is required are not applicable. The
development will not generate 500 or more peak hour trips. Chelsea Avenue is classified by TDOT as
an Urban Minor Arterial, but the AADT is less than 15,000 and the development will not generate 150
or more peak hour trips along Chelsea Avenue. Tully Street is not currently classified by TDOT, but
the development will not generate 100 or more peak hour trips along Tully Street. Woodlawn Street is
not currently classified by TDOT, but the development will not generate 100 or more peak hour trips
along Woodlawn Street. The sixth criterion, which is applicable to this project, is as follows:
6. Any development that would generate peak hour trips equivalent to 1% of the adjacent
roadway AADT, or average weekday trips equivalent to 10% of the adjacent roadway AADT.
This criterion was evaluated using the TDOT count station on Chelsea Avenue east of the proposed
development. The results of the analysis are summarized below:
6. Based on TDOT historical traffic count data, Chelsea Avenue had an AADT of approximately
5,807 vehicles per day in 2025. Table 2 provides the results of the evaluation using these criteria.
Table 2: ECG Chelsea Trip Generation Analysis
Based on the results as described above and summarized in Table 2, the hourly and daily trips
produced by this development along Chelsea Avenue exceed the City of Memphis minimum criteria
for determining if a traffic study is required.
Chelsea Avenue 2025 AADT Peak Hour Trips % of AADT Greater than
1% AADT?
Average Weekday
Trips % of AADT Greater than
10% AADT?
TDOT Traffic History
Count 5,807 60 1.0% YES 705 12% YES
kimley-horn.com 6750 Poplar Avenue, Suite 600, Memphis, Tennessee 38138 901-374-9109
January 02, 2026
Mr. Jeffrey Penzes
Ms. Mahsan Ostadnia
City of Memphis
Division of Planning and Development
125 N. Main, Ste. 468
Memphis, Tennessee 38103
RE: Rezoning Application
Chelsea Avenue Project
Legal Description - Boundary of Parcels to be Rezoned
BEGINNING AT A POINT IN THE WEST LINE OF WOODLAWN STREET (60 FEET RIGHT OF WAY),
85.11 FEET NORTH OF THE NORTH LINE OF CHELSEA AVENUE (80 FEET RIGHT OF WAY),
BEING IN THE NORTH LINE OF THE LARRY BLAND PROPERTY AS DESCRIBED IN INSTRUMENT
BH 1636, BEING THE NORTH LINE OF LOT 73, SNOWDEN AND BRINKLEY SUBDIVISION AS
RECORDED IN PLAT BOOK 3 PAGE 38; THENCE NORTH 09 DEGREES 23 MINUTES 26
SECONDS EAST ALONG THE WEST LINE OF WOODLAWN STREET A DISTANCE OF 300.00
FEET TO THE SOUTH LINE OF THE MDM INVESTMENTS, LLC PROPERTY AS DESCRIBED IN
INSTRUMENT 21016675 AND BEING THE SOUTH LINE OF LOT 80, SNOWDEN AND BRINKLEY
SUBDIVISION; THENCE NORTH 80 DEGREES 08 MINUTES 55 SECONDS WEST ALONG THE
NORTH LINE OF LOT 79 AND LOT 58, SNOWDEN AND BRINKLEY SUBDIVISION, A DISTANCE
OF 400.04 FEET; THENCE SOUTH 09 DEGREES 20 MINUTES 59 SECONDS WEST ALONG THE
EAST LINE OF TULLY STREET A DISTANCE OF 436.94 FEET TO THE NORTH LINE OF THE MDM
INVESTMENTS, LLC PROPERTY AS DESCRIBED IN INSTRUMENT 20103237; THENCE SOUTH
80 DEGREES 18 MINUTES 58 SE CONDS EAST A DISTANCE OF 100.00 FEET ; THENCE NORTH
09 DEGREES 20 MINUTES 59 SECONDS EAST A DISTANCE OF 36.20 FEET; THENCE SOUTH 80
DEGREES 18 MINUTES 58 SECONDS EAST ALONG THE NORTH LINE OF LOT 68 AND LOT 69,
SNOWDEN AND BRINKLEY SUBDIVISION, A DISTANCE OF 100.00 FEET; THENCE NORTH 09
DEGREES 20 MINUTES 59 SECONDS EAST ALONG THE WEST LINE OF LOT 70, SNOWDEN AND
BRINKLEY SUBDIVISION , A DISTANCE OF 100.16 FEET; THENCE SOUTH 80 DEGREES 08
MINUTES 54 SECONDS EAST ALONG THE NORTH LINE OF LOT 70 AND LOT 71, SNOWDEN
AND BRINKLEY SUBDIVISION , A DISTANCE OF 99.82; THENCE SOUTH 80 DEGREES 08
MINUTES 54 SECONDS EAST ALONG THE NORTH LINE OF LOT 72 AND LOT 73, SNOWDEN
AND BRINKLEY SUBDIVISION, A DISTANCE OF 100.00 FEET TO THE POINT OF BEGINNING,
CONTAINING 143,686.31 SQUARE FEET / 3.30 ACRES MORE OR LESS.
Legend
polygonLayer
Override 1
Override 2
polygonLayer
Override 1
Roads
Parcels 0 0.06 0.12 0.18 0.24
mi
Map prepared through Shelby County Government's
online mapping Portal on 12/29/2025
¯
Source: City of Memphis website. First collected Oct 27, 2026.