RecordWell Data

Planning and Zoning Committee Agenda Documents 4.14.26

City of Memphis · Shelby County · meeting of Apr 14, 2026 · Agendas

Open the original document More from City of Memphis

This document is no longer listed on City of Memphis's website. We kept the copy we read.

Text

Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.

CITY OF MEMPHIS COUNCIL AGENDA CHECK OFF SHEET ___________________________________________________________________________________ | ONE ORIGINAL | Planning & Development | ONLY STAPLED | DIVISION |TO DOCUMENTS| Planning & Zoning COMMITTEE: 3/ 24/2026 DATE PUBLIC SESSION: 4 /14/2026 DATE ITEM (CHECK ONE) ORDINANCE X RESOLUTION REQUEST FOR PUBLIC HEARING = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = ITEM DESCRIPTION: Resolution pursuant to Chapter 9.6 of the Memphis and Shelby County Unified Development Code approving a planned development at the subject property located at 0 Ikea Way known as case number PD 2026-001 CASE NUMBER: PD 2026-001 DEVELOPMENT: Galleria of Memphis Planned Development LOCATION: 0 Ikea Way COUNCIL DISTRICTS: District 1 and Super District 9 – Positions 1, 2, and 3 OWNER/APPLICANT: Brad Smith REPRESENTATIVE: Mike Davis, The Reaves Firm REQUEST: Amendment to PD 2013-313 to allow a hotel AREA: +/-2.39 acres RECOMMENDATION: The Division of Planning and Development recommended Approval with outline plan conditions The Land Use Control Board recommended Approval with outline plan conditions RECOMMENDED COUNCIL ACTION: Public Hearing Not Required Hearing – April 14, 2025 = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = PRIOR ACTION ON ITEM: (1) APPROVAL - (1) APPROVED (2) DENIED 03/12/2026 DATE (1) Land Use Control Board ORGANIZATION - (1) BOARD / COMMISSION (2) GOV’T. ENTITY (3) COUNCIL COMMITTEE = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = FUNDING: (2) REQUIRES CITY EXPENDITURE - (1) YES (2) NO $ AMOUNT OF EXPENDITURE $ REVENUE TO BE RECEIVED SOURCE AND AMOUNT OF FUNDS $ OPERATING BUDGET $ CIP PROJECT #_______________________________ $ FEDERAL/STATE/OTHER = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = ADMINISTRATIVE APPROVAL: DATE POSITION _____________________________________________ ____________ PLANNER II _____________________________________________ ____________ DEPUTY ADMINISTRATOR _____________________________________________ ____________ ADMINISTRATOR _____________________________________________ ____________ DIRECTOR (JOINT APPROVAL) _____________________________________________ ____________ COMPTROLLER _____________________________________________ ____________ FINANCE DIRECTOR _____________________________________________ ____________ CITY ATTORNEY = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = _____________________________________________ ____________ CHIEF ADMINISTRATIVE OFFICER _____________________________________________ ____________ COMMITTEE CHAIRMAN 3/16/2026 3/16/2026 3/16/2026 Memphis City Council Summary Sheet PD 2026-001 RESOLUTION PURSUANT TO CHAPTER 9.6 OF THE MEMPHIS AND SHELB Y COUNTY UNIFIE D DEVELOPMENT CODE APPROVING A PLANNED D EVELOPMENT AT THE SUBJECT PROPERTY LOCATED AT 0 IKEA WAY, KNOWN AS CASE NUMBER PD 2026-005 • This item is a resolution with conditions to allow a hotel as an amendment to PD 2023-313; and • This resolution, if approved with conditions, will supersede the existing zoning for this property; and • The item may require future public improvement contracts. 1 LAND USE CONTROL BOARD RECOMMENDATION At its regular meeting on Thursday, March 12, 2026 the Memphis and Shelby County Land Use Control Board held a public hearing on the following application: CASE NUMBER: PD 2026-001 DEVELOPMENT: Galleria of Memphis Planned Development LOCATION: 0 Ikea Way COUNCIL DISTRICT(S): District 1 and Super District 9 – Positions 1, 2, and 3 OWNER/APPLICANT: Brad Smith REPRESENTATIVE: Mike Davis, The Reaves Firm REQUEST: Amendment to PD 2013-313 to allow a hotel EXISTING ZONING: Conservation Agriculture (CA) underlying PD 2013-313 Area A AREA: +/- 2.39 acres The following spoke in support: None The following spoke in opposition: None The Land Use Control Board reviewed the application and the staff report. A motion was made and seconded to recommend approval with conditions. The motion passed by a unanimous vote of 8-0 on the consent agenda. Respectfully, Chloe Christion Planner II Land Use and Development Services Division of Planning and Development Cc: Committee Members File 2 PD 2026-005 CONDITIONS Outline Plan Conditions – Revisions Proposed language is indicated in bold, underline; deletions are indicated in bold strikethrough Area A-3 I. Uses permitted: A. Hotel B. Any use permitted in Parcel I. A II. Bulk Regulations: A. The bulk regulations of the CMU-2 District shall apply in addition to the following: B. Maximum building height of five (5) stories. C. Maximum height of light standards 30 feet. III. Signs: A. The sign regulations of the CMU-2 District as found in UDC Section 4.9 shall apply. 3 All other conditions of this planned development are recommended to be unaltered. PD 2013-313 OUTLINE PLAN CONDITIONS 4 5 6 7 8 9 OUTLINE PLAN RESOLUTION PURSUANT TO CHAPTER 9.6 OF THE MEMPHIS AND SHELBY COUNTY UNIFIED DEVELOPMENT CO DE APPROVING A P LANNED DEVELOPMENT AT THE SUBJECT PROPERTY LOCATED AT 0 IKEA WAY, KNOWN AS CASE NUMBER PD 2026-001 WHEREAS, Chapter 9.6 of the Memphis and Shelby County Unified Development Code, being a section of the Joint Ordinance Resolution No. 5367, dated August 10, 2010, authorizes the Council of the City of Memphis to grant a planned development for certain stated purposes in the various zoning districts; and WHEREAS, Brad Smith filed an application with the Memphis and Shelby County Division of Planning and Development to amend to PD 2013-313 to allow a hotel; and WHEREAS, the Division of Planning and Development has received and reviewed the application in accordance with procedures, objectives and standards for planned developments as set forth in Chapter 9.6 with regard to the proposed development's impacts upon surrounding properties, availability of public facilities, both external and internal circulation, land use compatibility, and that the design and amenities are consistent with the public interest; and has submitted its findings and recommendation subject to outline plan conditions concerning the above considerations to the Memphis and Shelby County Land Use Control Board; and WHEREAS, a public hearing in relation thereto was held before the Memphis and Shelby County Land Use Control Board on March 12, 2026, and said Board has submitted its findings and recommendation subject to outline plan conditions concerning the above considerations to the Council of the City of Memphis; and WHEREAS, the Council of the City of Memphis has reviewed the aforementioned application pursuant to Tennessee Code Annotated Section 13-4- 202(B)(2)(B)(iii) and has determined that said development is consistent with the Memphis 3.0 General Plan; and WHEREAS, the Council of the City of Memphis has reviewed the recommendation of the Land Use Control Board and the report and recommendation of the Division of Planning and Development and has determined that said development meets the objectives, standards and criteria for a special use permit, and said development is consistent with the public interests. NOW, THEREFORE, BE IT RESOLVED, BY THE COUNCIL OF THE CITY OF MEMPHIS, that, pursuant to Chapter 9.6 of the Memphis and Shelby County Unified Development Code, a planned development is hereby granted in accordance with the attached outline plan conditions. BE IT FURTHER RESOLVED , t hat the requirements of said aforementioned clause of the Unified Development Code shall be deemed to have been complied with; that the outline plan shall bind the applicant, owner, mortgagee, if any, and the legislative body with respect to the contents of said plan; and the applicant and/or owner may file a final plan in accordance with said outline plan and the provisions of Section 9.6.11 of the Unified Development Code. OUTLINE PLAN CONDITIONS Area A-3 I. Uses permitted: A. Hotel B. Any use permitted in Parcel I. A II. Bulk Regulations: A. The bulk regulations of the CMU-2 District shall apply in addition to the following: B. Maximum building height of five (5) stories. C. Maximum height of light standards 30 feet. III. Signs: A. The sign regulations of the CMU-2 District as found in UDC Section 4.9 shall apply. All other conditions of this planned development are recommended to be unaltered. OUTLINE PLAN ATTEST: CC: Division of Planning and Development – Land Use and Development Services – Office of Construction Enforcement Staff Writer: Chloe Christion E-mail: chleo.christion@memphistn.gov AGENDA ITEM: 6 L.U.C.B. MEETING: March 12, 2026 CASE NUMBER: PD 2026-001 DEVELOPMENT: Galleria of Memphis Planned Development LOCATION: 0 Ikea Way COUNCIL DISTRICT: District 1 and Super District 9 OWNER/APPLICANT: Brad Smith REPRESENTATIVE: Mike Davis, The Reaves Firm REQUEST: Amendment to PD 2013-313 to allow a hotel EXISTING ZONING: Conservation Agriculture (CA) underlying PD 2013-313 Area A CONCLUSIONS 1. The concept plan creates a new Area A -3 in the Galleria of Memphis Planned Development in which a hotel is a permitted use in addition to other uses permitted in Area A of the previous planned development. Note the previous planned development permits any use allowed by right or via the Administrative Site Plan Review (ASPR) process in the Commercial Mixed -Use – 2 (CMU -2) District excluding specific uses such as a church, pawn shop, and vehicle wash. See pages 16-21 for said outline plan conditions. 2. The amendment requires signs to adhere to the standards o f the Commercial Mixed -Use - 2 (CMU-2) District and permits a building height of up to five stories. This places any proposed hotel erected on the site in the height range of existing hotels on Ikea Way and Market Plaza Drive that range from four to five stories in height. 3. Given the commercial nature of the properties within the Galleria of Memphis Planned Development and the amount of existing hotels, an amendment to this planned development to allow a hotel is appropriate and matches the character and rhythm of the surrounding area. 4. The project will not have a substantial or undue adverse effect upon adjacent property, the character of the neighborhood, traffic conditions, parking, utility facilities and other matters affecting the public health, safety, and general welfare. CONSISTENCY WITH MEMPHIS 3.0 This proposal is not applicable to the Memphis 3.0 General Plan per the land use decision criteria. RECOMMENDATION: Approval with conditions Staff Report March 12, 2026 PD 2026-001 Page 2 2 LOCATION MAP Subject property located within the pink circle SUBJECT PROPERTY Staff Report March 12, 2026 PD 2026-001 Page 3 3 PUBLIC NOTICE VICINITY MAP Subject property outlined in red PUBLIC NOTICE DETAILS In accordance with Sub-Section 9.3.4A of the Unified Development Code, a notice of public hearing is required to be mailed and signage posted. A total of 26 notices were mailed on February 20, 2026 , see page 31 of this report for a copy of said notice. Additionally, one sign was posted at the subject property, see page 32 of this report for a copy of the sign affidavit. NEIGHBORHOOD MEETING The meeting was held at 6:00 PM on Thursday, February 26, 2026, at Hilton Garden Inn at 7955 Ikea Way. Staff Report March 12, 2026 PD 2026-001 Page 4 4 AERIAL Subject property outlined in yellow, imagery from 2025 Staff Report March 12, 2026 PD 2026-001 Page 5 5 ZONING MAP Subject property highlighted in yellow Staff Report March 12, 2026 PD 2026-001 Page 6 6 LAND USE MAP Subject property indicated by a pink star Staff Report March 12, 2026 PD 2026-001 Page 7 7 SITE PHOTOS View of subject property from Ikea Way facing south. Staff Report March 12, 2026 PD 2026-001 Page 8 8 OUTLINE PLAN Staff Report March 12, 2026 PD 2026-001 Page 9 9 Staff Report March 12, 2026 PD 2026-001 Page 10 10 Staff Report March 12, 2026 PD 2026-001 Page 11 11 LANDSCAPE PLAN Staff Report March 12, 2026 PD 2026-001 Page 12 12 CASE REVIEW Request The request is an amendment to PD 2013-303 to allow a hotel. Applicability Staff agrees the applicability standards and criteria as set out in Section 4.10.2 of the Unified Development Code are or will be met. 4.10.2 Applicability The governing bodies may, upon proper application, grant a special use permit for a planned development (see Chapter 9.6) for a tract of any size within the City or for tracts of at least three acres in unincorporated Shelby County to facilitate the use of flexible techniques of land development and site design, by providing relief from district requirements designed for conventional developments, and may establish standards and procedures for planned developments in order to obtain one or more of the following objectives: A. Environmental design in the development of land that is of a higher quality than is possible under the regulations otherwise applicable to the property. B. Diversification in the uses permitted and variation in the relationship of uses, structures, open space and height of structures in developments intended as cohesive, unified projects. C. Functional and beneficial uses of open space areas. D. Preservation of natural features of a development site. E. Creation of a safe and desirable living environment for residential areas characterized by a unified building and site development program. F. Rational and economic development in relation to public services. G. Efficient and effective traffic circulation, both within and adjacent to the development site, that supports or enhances the approved transportation network. H. Creation of a variety of housing compatible with surrounding neighborhoods to provide a greater choice of types of environment and living units. I. Revitalization of established commercial centers of integrated design to order to encourage the rehabilitation of such centers in order to meet current market preferences. J. Provision in attractive and appropriate locations for business and manufacturing uses in well -designed buildings and provision of opportunities for employment closer to residence with a reduction in travel time from home to work. K. Consistency with the Memphis 3.0 General Plan. General Provisions Staff agrees the general provisions standards and criteria as set out in Section 4.10.3 of the Unified Development Code are or will be met. 4.10.3 General Provisions The governing bodies may grant a special use permit for a planned development which modifies the applicable district regulations and other regulations of this development code upon written findings and recommendations of the Land Use Control Board and the Zoning Administrator which shall be forwarded pursuant to provisions contained in this Chapter. A. The proposed development will not unduly injure or damage the use, value and enjoyment of surrounding Staff Report March 12, 2026 PD 2026-001 Page 13 13 property nor unduly hinder or prevent the development of surrounding property in accordance with the current development policies and plans of the City and County. B. An approved water supply, community waste water treatment and disposal, and storm water drainage facilities that are adequate to serve the proposed development have been or will be provided concurrent with the development. C. The location and arrangement of the structures, parking areas, walks, lighting and other service facilities shall be compatible with the surrounding land uses, and any part of the proposed development not used for structures, parking and loading areas or access way shall be landscaped or otherwise improved except where natural features are such as to justify preservation. D. Any modification of the district standards that would otherwise be applicable to the site are warranted by the design of the outline plan and the amenities incorporated therein, and are not inconsistent with the public interest. E. Homeowners’ associations or some other responsible party shall be required to maintain any and all common open space and/or common elements. F. Lots of record are created with the recording of a planned development final plan. Commercial or Industrial Criteria Staff agrees the additional planned commercial or industrial development criteria as set out in Section 4.10.5 of the Unified Development Code are or will be met. 4.10.5 Planned Commercial or Industrial Developments Approval of a planned commercial or industrial development may be issued by the governing bodies for buildings or premises to be used for the retail sale of merchandise and services, parking areas, office buildings, hotels and motels and similar facilities ordinarily accepted as commercial center uses and those industrial uses which can be reasonably be expected to function in a compatible manner with the other permitted uses in the area. In addition to the applicable standards and criteria set forth in Section 4.10.3, planned commercial or industrial developments shall comply with the following standards: A. Screening When commercial or industrial structures or uses in a planned commercial or industrial development abut a residential district or permitted residential buildings in the same development, screening may be required by the governing bodies. B. Display of Merchandise All business, manufacturing and processing shall be conducted, and all merchandise and materials shall be displayed and stored, within a completely enclosed building or within an open area which is completely screened from the view of adjacent properties and public rights -of-way, provided, however, that when an automobile service station or gasoline sales are permitted in a planned commercial development, gasoline may be sold from pumps outside of a structure. C. Accessibility The site shall be accessible from the proposed street network in the vicinity which will be adequate to carry the anticipated traffic of the proposed development. The streets and driveways on the site of the proposed development shall be adequate to serve the enterprises located in the proposed development. D. Landscaping Landscaping shall be required to provide screening of objectionable views of uses and the reduction of noise. High-rise buildings shall be located within the development in such a way as to minimize any adverse impact on adjoining low-rise buildings. Staff Report March 12, 2026 PD 2026-001 Page 14 14 Approval Criteria Staff agrees the approval criteria as set out in Section 9.6.9 of the Unified Development Code are being met. 9.6.9 Approval Criteria No special use permit or planned development shall be approved unless the following findings are made concerning the application: A. The project will not have a substantial or undue adverse effect upon adjacent property, the character of the neighborhood, traffic conditions, parking, utility facilities and other matters affecting the public health, safety, and general welfare. B. The project will be constructed, arranged and operated so as to be compatible with the immediate vicinity and not interfere with the development and use of adjacent property in accordance with the applicable district regulations. C. The project will be served adequately by essential public facilities and services such as streets, parking, drainage, refuse disposal, fire protection and emergency services, water and sewers; or that the applicant will provide adequately for such services. D. The project will not result in the destruction, loss or damage of any feature determined by the governing bodies to be of significant natural, scenic or historic importance. E. The project complies with all additional standards imposed on it by any particular provisions authorizing such use. F. The request will not adversely affect any plans to be considered (see Chapter 1.9), or violate the character of existing standards for development of the adjacent properties. G. The governing bodies may impose conditions to minimize adverse effects on the neighborhood or on public facilities, and to ensure compatibility of the proposed development with surrounding properties, uses, and the purpose and intent of this development code. H. Any decision to deny a special use permit request to place, construct, or modify personal wireless service facilities shall be in writing and supported by substantial evidence contained in a written record, per the Telecommunications Act of 1996, 47 USC 332(c)(7)(B)(iii). The review body may not take into account any environmental or health concerns. Site Details Address: 0 Ikea Way Parcel ID: 096500 00722 Area: +/- 2.39 acres Description: The subject property is known as part of Area A within the Galleria of Memphis Planned Development (PD 2013- 313). The property is vacant and surrounded by commercial land uses including retail and hotel space. The lot has one street frontage on Ikea Way. Staff Report March 12, 2026 PD 2026-001 Page 15 15 Site Zoning History On July 2, 2013, the Council of the City of Memphis approved PD 2013-313 which allowed a planned development for the subject property at the intersection of Market Plaza Drive and Germantown Parkway. See pages 22-25 for said resolution. Concept Plan Review & Analysis The concept plan creates a new Area A-3 in the Galleria of Memphis Planned Development in which a hotel is a permitted use in addition to other uses permitted in Area A of the previous planned development. Note the previous planned development permi ts any use allowed by right or via the Administrative Site Plan Review (ASPR) process in the Commercial Mixed-Use – 2 (CMU-2) District excluding specific uses such as a church, pawn shop, and vehicle wash. See pages 16-21 for said outline plan conditions. The amendment requires signs to adhere to the standards o f the Commercial Mixed -Use -2 (CMU-2) District and permits a building height of up to five stories. This places any proposed hotel erected on the site in the height range of existing hotels on Ikea Way and Market Plaza Drive that range from four to five stories in height. Given the commercial nature of the properties within the Galleria of Memphis Planned Development and the amount of existing hotels, an amendment to this planned development to allow a hotel is appropriate and matches the character and rhythm of the surrounding area. The project will not have a substantial or undue adverse effect upon adjacent property, the character of the neighborhood, traffic conditions, parking, utility facilities and other matters affecting the public health, safety, and general welfare. RECOMMENDATION Staff recommends approval with revisions to the outline plan conditions. Outline Plan Conditions – Revisions Proposed language is indicated in bold, underline; deletions are indicated in bold strikethrough Area A-3 I. Uses permitted: A. Hotel B. Any use permitted in Parcel I. A II. Bulk Regulations: A. The bulk regulations of the CMU-2 District shall apply in addition to the following: B. Maximum building height of five (5) stories. C. Maximum height of light standards 30 feet. III. Signs: A. The sign regulations of the CMU-2 District as found in UDC Section 4.9 shall apply. Staff Report March 12, 2026 PD 2026-001 Page 16 16 All other conditions of this planned development are recommended to be unaltered. PD 2013-313 OUTLINE PLAN CONDITIONS Staff Report March 12, 2026 PD 2026-001 Page 17 17 Staff Report March 12, 2026 PD 2026-001 Page 18 18 Staff Report March 12, 2026 PD 2026-001 Page 19 19 Staff Report March 12, 2026 PD 2026-001 Page 20 20 Staff Report March 12, 2026 PD 2026-001 Page 21 21 Staff Report March 12, 2026 PD 2026-001 Page 22 22 PD 2013-313 APPROVED RESOLUTION Staff Report March 12, 2026 PD 2026-001 Page 23 23 Staff Report March 12, 2026 PD 2026-001 Page 24 24 Staff Report March 12, 2026 PD 2026-001 Page 25 25 Staff Report March 12, 2026 PD 2026-001 Page 26 26 DEPARTMENTAL COMMENTS The following comments were provided by agencies to which this application was referred: City Engineer: See pages 18-20. County Engineer: No comments received. City Fire Division: All design and construction shall comply with the 2021 edition of the International Fire Code with local amendments and referenced standards. 1. Fire apparatus access shall comply with section 503. 2. Where security gates are installed that affect required fire apparatus access roads, they shall comply with section 503.6. 3. Fire protection water supplies (including fire hydrants) shall comply with section 507. 4. Where fire apparatus access roads or a water supply for fire protection are required to be installed, such protection shall be installed and made serviceable prior to and during the time of construction except when approved alternate methods of protection are provided. 5. IFC 510 In-building two-way emergency responder communication coverage shall be provided in all new and existing buildings. Buildings and structures that cannot support the required level of coverage shall be equipped with systems and components to enhance signals and achieve the required level of communication coverage. 6. A detailed plans review will be conducted by the Memphis Fire Prevention Bureau upon receipt of complete construction documents. Plans shall be submitted to the Shelby County Office of Code Enforcement. County Fire Division: No comments received. City Real Estate: No comments received. County Health Department: No comments received. Shelby County Schools: No comments received. Construction Code Enforcement: No comments received. Memphis Light, Gas and Water: No comments received. Office of Sustainability and Resilience: No comments received. Staff Report March 12, 2026 PD 2026-001 Page 27 27 Office of Comprehensive Planning: No comments received. Staff Report March 12, 2026 PD 2026-001 Page 28 28 ENGINEERING COMMENTS CASE 1: PD-26-001 Amend PD-13-313 to allow a hotel NAME: 0 Ikea Way; 096500 00722 Basin/Lot/CD: Fletcher Creek, 12-A/ 2.39ac/1 1. Standard Public Improvement Contract or Right-Of-Way Permit as required in Section 5.5.5 of the Unified Development Code. Sewers: 2. City sanitary sewer capacity is available and needs to meet the requirement of the sewer connection letter issued on 19 Dec 2025 by the Public Works director. 3. The site is in Fletcher Creek sewer basin. Attached is the letter. Staff Report March 12, 2026 PD 2026-001 Page 29 29 Roads: 4. The Developer shall be responsible for the repair and/or replacement of all existing curb and gutter along the frontage of this site as necessary. 5. All existing sidewalks and curb openings along the frontage of this site shall be inspected for ADA compliance. The developer shall be responsible for any reconstruction or repair necessary to meet City standards. Traffic Control Provisions: 6. The developer shall provide a traffic control plan to the city engineer that shows the phasing for each street frontage during demolition and construction of curb gutter and sidewalk. Upon completion of sidewalk and curb and gutter improvements, a minimum 5 foot wide pedestrian pathway shall be provided throughout the remainder of the project. In the event that the existing right of way width does not allow for a 5 foot clear pedestrian path, an exception may be considered. 7. Any closure of the right of way shall be time limited to the active demolition and construction of sidewalks and curb and gutter. Continuous unwarranted closure of the right of way shall not be allowed for the duration of the project. The developer shall provide on the traffic control plan, the time needed per phase to complete that portion of the work. Time limits will begin on the day of closure and will be monitored by the Engineering construction inspectors on the job. 8. The developer’s engineer shall submit a Trip Generation Report that documents the proposed land use, scope and anticipated traffic demand associated with the proposed development. A detailed Traffic Impact Study will be required when the accepted Trip Generation Report indicates that the number for projected trips meets or exceeds the criteria listed in Section 210-Traffic Impact Policy for Land Development of the City of Memphis Division of Engineering Design and Policy Review Manual. Any required Traffic Impact Study will need to be formally approved by the City of Memphis, Traffic Engineering Department. Curb Cuts/Access: 9. The City Engineer shall approve the design, number, and location of curb cuts. 10. Any existing nonconforming curb cuts shall be modified to meet current City Standards or closed with curb, gutter, and sidewalk. 11. Will require engineering ASPR. Drainage: 12. A grading and drainage plan for the site shall be submitted to the City Engineer for review and approval prior to recording of the final plat. 13. Drainage improvements, including possible on-site detention, shall be provided under a Standard Subdivision contract in accordance with Unified Development Code and the City of Memphis/Shelby County Storm Water Management Manual. 14. Drainage data for assessment of on-site detention requirements shall be submitted to the City Engineer. Staff Report March 12, 2026 PD 2026-001 Page 30 30 15. The following note shall be placed on the final plat of any development requiring on-site storm water detention facilities: The areas denoted by "Reserved for Storm Water Detention" shall not be used as a building site or filled without first obtaining written permission from the City and/or County Engineer. The storm water detention systems located in these areas, except for those parts located in a public drainage easement, shall be owned and maintained by the property owner and/or property owners' association. Such maintenance shall be performed so as to ensure that the system operates in accordance with the approved plan on file in the City and/or County Engineer's Office. Such maintenance shall include, but not be limited to removal of sedimentation, fallen objects, debris and trash, mowing, outlet cleaning, and repair of drainage structures. 16. The developer should be aware of his obligation under 40 CFR 122.26(b)(14) and TCA 69-3-101 et. seq. to submit a Notice of Intent (NOI) to the Tennessee Division of Water Pollution Control to address the discharge of storm water associated with the clearing and grading activity on this site. General Notes: 17. Development is greater than 1 acre and is located within a sensitive drainage basin. Detention and engineering review are required. 18. No other utilities or services may occupy sanitary sewer easements in private drives and yards except for crossings. 19. All connections to the sewer shall be at manholes only. 20. All commons, open areas, lakes, drainage detention facilities, private streets, private sewers and private drainage systems shall be owned and maintained by a Property Owner's Association. A statement to this effect shall appear on the final plat. 21. Required landscaping shall not be placed on sewer or drainage easements. Staff Report March 12, 2026 PD 2026-001 Page 31 31 MAILED PUBLIC NOTICE Staff Report March 12, 2026 PD 2026-001 Page 32 32 SIGN AFFIDAVIT Staff Report March 12, 2026 PD 2026-001 Page 33 33 APPLICATION Staff Report March 12, 2026 PD 2026-001 Page 34 34 Staff Report March 12, 2026 PD 2026-001 Page 35 35 Staff Report March 12, 2026 PD 2026-001 Page 36 36 Staff Report March 12, 2026 PD 2026-001 Page 37 37 OWNER AFFIDAVIT Staff Report March 12, 2026 PD 2026-001 Page 38 38 LETTER OF INTENT Staff Report March 12, 2026 PD 2026-001 Page 39 39 LETTERS RECEIVED No letters received at the time of completion of this report. East Service Center: 6465 Mullins Station Rd; Memphis, Tennessee 38134 Downtown Service Center: 125 N. Main Street; Memphis, T ennessee 38103 website: www.develop901.com Memphis and Shelby County Division of Planning and Development Record Summary for Planned Development Record Detail Information Record T ype: Planned Development Record Status: Additional Info Required Opened Date: January 28, 2026 Record Number: PD 2026-001 Record Name: Galleria of Memphis PD Amendment Expiration Date: Description of Work: On behalf of StoneCrest Investments, the applicant, and ownership group GRH Glenwood LLC, MRH Venture Capital LLC, Stephens Holdings LLC, MEMTEX Development No 1 LLC, and Ryan Family Ventures LLC, we are pleased to submit the attached amendment to the Galleria of Memphis PD (PD 13-0313). The purpose of the application is to modify the outline plan to create Area A-3 within Parcel 1, a 2.39 acre lot consisting entirely of Parcel No. 096500 00722 to allow for hotel use with a height of 5 stories. We had a pre-application meeting on January 9, 2026. Parent Record Number: Address: 0 Ikea Way 38016 Owner Information Primary Owner Name Owner Address Owner Phone Y GRH GLENWOOD LLC AND MRH VENTURE CAPIT AL 595 ROUND ROCK WEST DR, ROUND ROCK, TX 78681 Parcel Information 096500 00722 Data Fields PREAPPLICA TION MEETING Name of DPD Planner Chloe Date of Meeting 01/09/2026 Pre-application Meeting Type In Person GENERAL PROJECT INFORMATION Page 1 of 4 PD 2026-001 Planned Development Type Amendment to Existing PD Previous Docket / Case Number 13-313 08-326 04-312 90-315 CC Medical Overlay / Uptown No If this development is located in unincorporated Shelby County, is the tract at least three acres? (Note a tract of less than three acres is not eligible for a planned development in unincorporated Shelby County) N/A Is this application in response to a citation, stop work order, or zoning letter No If yes, please provide a copy of the citation, stop work order, and/or zoning letter along with any other relevant information - APPROVAL CRITERIA UDC Sub-Section 9.6.9A The immediately adjacent property has 3 hotels: two to the west at four and five stories and one to the south at four stories. There is Ikea to the northwest and a retail center to the east. Directly north is a large stormwater detention pond associated with another retail center. A maximum five-story hotel is in keeping with the neighborhood. The property is located on a fully-improved street and all public utilities are readily available. UDC Sub-Section 9.6.9B Correct. The applicant plans to build a maximum five-story hotel on this site, which is consistent with surrounding property, most of which are stand alone and fully developed. UDC Sub-Section 9.6.9C The area is embedded within an existing commercial area and as such is supported by fully improved infrastructure and utilities. UDC Sub-Section 9.6.9D The site is an open field with no known scenic or historical features. UDC Sub-Section 9.6.9E With the granting of the PD amendment to the outline plan for the hotel and to allow five stories in height, this project complies with UDC standards. UDC Sub-Section 9.6.9F The project complies with building and zoning code, is compatible with adjacent property, and will cause no violations. GENERAL PROVISIONS UDC Sub-Section 4.10.3A Correct. B) An approved water supply, community waste water treatment and disposal, and storm water drainage facilities that are adequate to serve the proposed development have been or will be provided concurrent with the development All utilities are existing on or near this property. Page 2 of 4 PD 2026-001 GENERAL PROVISIONS C) The location and arrangement of the structures, parking and loading areas, walks, lighting and other service facilities shall be compatible with the surrounding land uses, and any part of the proposed development not used for such facilities shall be landscaped or otherwise improved except where natural features are such as to justify preservation Correct D) Any modification of the district standards that would otherwise be applicable to the site are warranted by the design of the outline plan and the amenities incorporated therein, and are not inconsistent with the public interest Correct E) Homeowners’ associations or some other responsible party shall be required to maintain any and all common open space and/or common elements Understood. F) Lots of record are created with the recording of a planned development final plan Understood. GIS INFORMATION Case Layer PD16-010, PD13-313, PD04-312 Central Business Improvement District No Class C Downtown Fire District No Historic District - Land Use V ACANT Municipality - Overlay/Special Purpose District Fletcher Creek Overlay Zoning CA State Route - Lot - Subdivision GALLERIA OF MEMPHIS PD AMENDED PAR 1 AND Planned Development District - Wellhead Protection Overlay District No County Commission District - City Council District - City Council Super District - Contact Information Page 3 of 4 PD 2026-001 BRAD SMITH 595 ROUND ROCK WEST DR, MEMTEX DEVELOPMENT # 1, ROUND ROCK, TX, ROUND ROCK, TX, 78681 - APPLICANT Name Address Phone Contact Type GREG BARTLETT 6800 POPLAR AVE, (901)761-2016 ARCHITECT / ENGINEER / SURVEYOR Name Address Phone Contact Type CHRISTINE DONHARDT 6800 POPLAR AVE, (901)761-2016 MANAGER Name Address Phone Contact Type BRAD SMITH 595 ROUND ROCK WEST DR, MEMTEX DEVELOPMENT # 1, ROUND ROCK, TX, ROUND ROCK, TX, 78681 (901)761-2016 PROPER TY OWNER OF RECORD Name Address Phone Contact Type MIKE DAVIS (901)761-2016 REPRESENT ATIVE Name Address Phone Contact Type Fee Information Date AssessedBalanceStatusFeesQuantityFee ItemInvoice # 01/28/20260.00INVOICED0.001Credit Card Use Fee (.026 x fee) 1703562 01/29/20260.00INVOICED1,500.001Planned Development - 5 acres or less 1703585 Total Fee Invoiced : $1,500.00 Total Balance: $0.00 Payment Information Payment Amount Method of Payment Check$1,500.00 Page 4 of 4 PD 2026-001 6800 Poplar Avenue, Suite 101 Memphis, TN 38138 T. 901.761.2016 / F. 901.763.2847 January 30, 2026 Mr. Brett Ragsdale Division of Planning and Development 125 N. Main, Ste. 477 Memphis, TN 38103 RE: Galleria of Memphis PD Dear Brett, On behalf of Stone Crest Investments, the applicant, and ownership group GRH Glenwood LLC, MRH Venture Capital LLC, Stephens Holdings LLC, MEMTEX Development No 1 LLC, and Ryan Family Ventures LLC, we are pleased to submit the attached amendment to the Galleria of Memphis PD (PD 13-0313). The purpose of the application is to modify the outline plan to create Area A-3 within Parcel 1, a 2.39 acre lot consisting entirely of Parcel No. 096500 00722 to allow for hotel use with a height of 5 stories. We had a pre-application meeting on January 9, 2026. Sincerely, Mike Davis, R.L.A. Principal IKEA WAY MARKET FARMS DRIVE BELLEVUE PARKWAY NORTH GERMANTOWN PARKWAY ROCKCREEK PKWY. VARNAVAS PARCEL I AREA F PARCEL I AREA A PARCEL I AREA A PARCEL I AREA B-2 PARCEL I AREA B-1 PARCEL I AREA D-2 PARCEL I AREA D-1 PARCEL I AREA D PARCEL I AREA A-3 ±2.4 AC. 15' PRIVATE DRAIN ESM'T (P.B. 237 P.G. 37) 15' PUBLIC SEWER ESM'T (P.B. 222 P.G. 51) S86°28'25"E 173.00' S3°30'40"W 55.76' N86°29'45"W 172.88' S3°30'40"W 455.39' N3°30'40"E 610.05' RAD=67.00' ARC=111.15' TAN=73.18' MEMPHIS, TENNESSEE 250.34 ACRES DEVELOPER: STONECREST INVESTMENTS ENGINEER: THE REAVES FIRM JANUARY 2026 SCALE: 1" = 200' SHEET 1 OF 7 GALLERIA OF MEMPHIS PLANNED DEVELOPMENT 100-YEAR FLOOD ELEV: 280.0 ± FEMA MAP PANEL NO: 310 G, 316 G FEMA MAP DATE: FEB. 6, 2013 6800 Poplar Avenue, Suite 101 Memphis, TN 38138 901.761.2016 Fax: 901.763.2847 www.ReavesFirm.com Engineering Planning Landscape Architecture Land Surveying The Reaves Firm INCORPORATED OUTLINE PLAN P.D. 26-______ (FORMERLY P.D. 13-313, P.D. 08-326, P.D. 04-312, & P.D. 90-315 CC) GRAPHIC SCALE IN FEET North 0 200 SCALE: 1" = 200' 200 JOB # 25-0216 THIS SHEET IS BEING ADDED TO SHOW THE CREATION OF AREA A-3 IN PARCEL I. PROPOSED CONDITIONS FOR AREA A-3 ARE LISTED BELOW. UNLESS OTHERWISE SPECIFIED, THE EXISTING CONDITIONS OF AREA A SHALL APPLY TO AREA A-3. ALL OTHER CONDITIONS FOR THIS PLANNED DEVELOPMENT ARE RECOMMENDED TO BE UNALTERED. SHEETS 2-4 ARE TAKEN FROM THE OUTLINE PLAN RECORDED IN PL. BK. 267, PG. 1. PD 26- ____ (Galleria of Memphis Planned Development Amendment) Outline Plan Conditions for Area A-3 I. Uses permitted: A. Hotel and any use permitted in Area A. II. Bulk Regulation: A. Maximum five (5) stories B. Maximum height of light standards 30 feet. III. Signs: A. Signs as allowed in CMU-2 District 6800 Poplar Avenue, Suite 101 Memphis, TN 38138 901.761.2016 Fax: 901.763.2847 www.ReavesFirm.com Engineering Planning Landscape Architecture Land Surveying The Reaves Firm INCORPORATED MEMPHIS, TENNESSEE 250.34 ACRES DEVELOPER: STONECREST INVESTMENTS ENGINEER: THE REAVES FIRM JANUARY 2026 SCALE: N/A SHEET 5 OF 7 GALLERIA OF MEMPHIS PLANNED DEVELOPMENT 100-YEAR FLOOD ELEV: 280.0 ± FEMA MAP PANEL NO: 310 G, 316 G FEMA MAP DATE: FEB. 6, 2013 OUTLINE PLAN P.D. 26-______ (FORMERLY P.D. 13-313, P.D. 08-326, P.D. 04-312, & P.D. 90-315 CC) JOB # 25-0216 “ ” “ ” ç ç “ ” “ ” · · · · · · · · · · 6800 Poplar Avenue, Suite 101 Memphis, TN 38138 901.761.2016 Fax: 901.763.2847 www.ReavesFirm.com Engineering Planning Landscape Architecture Land Surveying The Reaves Firm INCORPORATED MEMPHIS, TENNESSEE 250.34 ACRES DEVELOPER: STONECREST INVESTMENTS ENGINEER: THE REAVES FIRM JANUARY 2026 SCALE: N/A SHEET 6 OF 7 GALLERIA OF MEMPHIS PLANNED DEVELOPMENT 100-YEAR FLOOD ELEV: 280.0 ± FEMA MAP PANEL NO: 310 G, 316 G FEMA MAP DATE: FEB. 6, 2013 OUTLINE PLAN P.D. 26-______ (FORMERLY P.D. 13-313, P.D. 08-326, P.D. 04-312, & P.D. 90-315 CC) JOB # 25-0216 ENGINEER'S CERTIFICATE I hereby certify that this plat is true and correct, is in conformance with the design requirements of the Memphis and Shelby County Unified Development Code, the specific conditions imposed on this development, and takes into account all applicable federal, state and local building laws and regulations. By: (Seal) Date: . Tennessee License No. . LAND USE AND DEVELOPMENT SERVICES CERTIFICATE This final plat conforms with the planned development acted on by the Land Use Control Board on and approved by the Council of the City of Memphis on . By: . Date: . Zoning Administrator LUDS: . Date: . SURVEYOR'S CERTIFICATE I hereby certify that this is a category 1 survey and that the precision of the unadjusted survey is 1: 10,000 or greater; that this plat has been prepared by me or under my individual supervision and conforms with applicable state laws, the Memphis and Shelby County Unified Development Code, and specific conditions imposed on this development relating to the practice of surveying. By: (Seal) Date: . Tennessee License No. . NOTARY'S CERTIFICATE State of Tennessee County of Shelby Before me, the undersigned, a Notary Public in and for the said State and County at Memphis, duly commissioned and qualified, personally appeared with whom I am personally acquainted, and who upon his oath acknowledged himself to be the of , the within named bargainer, and that he executed the foregoing instrument for the purpose therein contained. In witness whereof, I have hereunto set my hand and affixed my notarial seal at my office this day of , 2026. Notary Public . My Commission Expires . OWNER'S CERTIFICATE We, , the undersigned owner of the property shown, hereby adopt this plat as our plan of development and dedicate the streets, right-of-way, and grant the easements as shown and/or described to public use forever. We certify that we are the owners of the said property in fee simple, duly authorized to act, and that said property is not encumbered by any taxes or mortgages which have become due and payable. Signature: . NOTARY'S CERTIFICATE State of Tennessee County of Shelby Before me, the undersigned, a Notary Public in and for the said State and County at Memphis, duly commissioned and qualified, personally appeared with whom I am personally acquainted, and who upon his oath acknowledged himself to be the of , the within named bargainer, and that he executed the foregoing instrument for the purpose therein contained. In witness whereof, I have hereunto set my hand and affixed my notarial seal at my office this day of , 2026. Notary Public . My Commission Expires . OWNER'S CERTIFICATE We, , the undersigned owner of the property shown, hereby adopt this plat as our plan of development and dedicate the streets, right-of-way, and grant the easements as shown and/or described to public use forever. We certify that we are the owners of the said property in fee simple, duly authorized to act, and that said property is not encumbered by any taxes or mortgages which have become due and payable. Signature: . NOTARY'S CERTIFICATE State of Tennessee County of Shelby Before me, the undersigned, a Notary Public in and for the said State and County at Memphis, duly commissioned and qualified, personally appeared with whom I am personally acquainted, and who upon his oath acknowledged himself to be the of , the within named bargainer, and that he executed the foregoing instrument for the purpose therein contained. In witness whereof, I have hereunto set my hand and affixed my notarial seal at my office this day of , 2026. Notary Public . My Commission Expires . OWNER'S CERTIFICATE We, , the undersigned owner of the property shown, hereby adopt this plat as our plan of development and dedicate the streets, right-of-way, and grant the easements as shown and/or described to public use forever. We certify that we are the owners of the said property in fee simple, duly authorized to act, and that said property is not encumbered by any taxes or mortgages which have become due and payable. Signature: . NOTARY'S CERTIFICATE State of Tennessee County of Shelby Before me, the undersigned, a Notary Public in and for the said State and County at Memphis, duly commissioned and qualified, personally appeared with whom I am personally acquainted, and who upon his oath acknowledged himself to be the of , the within named bargainer, and that he executed the foregoing instrument for the purpose therein contained. In witness whereof, I have hereunto set my hand and affixed my notarial seal at my office this day of , 2026. Notary Public . My Commission Expires . OWNER'S CERTIFICATE We, , the undersigned owner of the property shown, hereby adopt this plat as our plan of development and dedicate the streets, right-of-way, and grant the easements as shown and/or described to public use forever. We certify that we are the owners of the said property in fee simple, duly authorized to act, and that said property is not encumbered by any taxes or mortgages which have become due and payable. Signature: . 6800 Poplar Avenue, Suite 101 Memphis, TN 38138 901.761.2016 Fax: 901.763.2847 www.ReavesFirm.com Engineering Planning Landscape Architecture Land Surveying The Reaves Firm INCORPORATED MEMPHIS, TENNESSEE 250.34 ACRES DEVELOPER: STONECREST INVESTMENTS ENGINEER: THE REAVES FIRM JANUARY 2026 SCALE: N/A SHEET 7 OF 7 GALLERIA OF MEMPHIS PLANNED DEVELOPMENT 100-YEAR FLOOD ELEV: 280.0 ± FEMA MAP PANEL NO: 310 G, 316 G FEMA MAP DATE: FEB. 6, 2013 OUTLINE PLAN P.D. 26-______ (FORMERLY P.D. 13-313, P.D. 08-326, P.D. 04-312, & P.D. 90-315 CC) JOB # 25-0216 IKEA WAY MARKET FARMS DRIVE BELLEVUE PARKWAY NORTH GERMANTOWN PARKWAY ROCKCREEK PKWY. VARNAVAS PARCEL I AREA F PARCEL I AREA A PARCEL I AREA A PARCEL I AREA B-2 PARCEL I AREA B-1 PARCEL I AREA D-2 PARCEL I AREA D-1 PARCEL I AREA D PARCEL I AREA A-3 ±2.4 AC. 15' PRIVATE DRAIN ESM'T (P.B. 237 P.G. 37) 15' PUBLIC SEWER ESM'T (P.B. 222 P.G. 51) S86°28'25"E 173.00' S3°30'40"W 55.76' N86°29'45"W 172.88' S3°30'40"W 455.39' N3°30'40"E 610.05' RAD=67.00' ARC=111.15' TAN=73.18' MEMPHIS, TENNESSEE 250.34 ACRES DEVELOPER: STONECREST INVESTMENTS ENGINEER: THE REAVES FIRM JANUARY 2026 SCALE: 1" = 200' SHEET 1 OF 7 GALLERIA OF MEMPHIS PLANNED DEVELOPMENT 100-YEAR FLOOD ELEV: 280.0 ± FEMA MAP PANEL NO: 310 G, 316 G FEMA MAP DATE: FEB. 6, 2013 6800 Poplar Avenue, Suite 101 Memphis, TN 38138 901.761.2016 Fax: 901.763.2847 www.ReavesFirm.com Engineering Planning Landscape Architecture Land Surveying The Reaves Firm INCORPORATED OUTLINE PLAN P.D. 26-______ (FORMERLY P.D. 13-313, P.D. 08-326, P.D. 04-312, & P.D. 90-315 CC) GRAPHIC SCALE IN FEET North 0 200 SCALE: 1" = 200' 200 JOB # 25-0216 THIS SHEET IS BEING ADDED TO SHOW THE CREATION OF AREA A-3 IN PARCEL I. PROPOSED CONDITIONS FOR AREA A-3 ARE LISTED BELOW. UNLESS OTHERWISE SPECIFIED, THE EXISTING CONDITIONS OF AREA A SHALL APPLY TO AREA A-3. ALL OTHER CONDITIONS FOR THIS PLANNED DEVELOPMENT ARE RECOMMENDED TO BE UNALTERED. SHEETS 2-4 ARE TAKEN FROM THE OUTLINE PLAN RECORDED IN PL. BK. 267, PG. 1. PD 26- ____ (Galleria of Memphis Planned Development Amendment) Outline Plan Conditions for Area A-3 I. Uses permitted: A. Hotel and any use permitted in Area A. II. Bulk Regulation: A. Maximum five (5) stories B. Maximum height of light standards 30 feet. III. Signs: A. Signs as allowed in CMU-2 District 6800 Poplar Avenue, Suite 101 Memphis, TN 38138 901.761.2016 Fax: 901.763.2847 www.ReavesFirm.com Engineering Planning Landscape Architecture Land Surveying The Reaves Firm INCORPORATED MEMPHIS, TENNESSEE 250.34 ACRES DEVELOPER: STONECREST INVESTMENTS ENGINEER: THE REAVES FIRM JANUARY 2026 SCALE: N/A SHEET 5 OF 7 GALLERIA OF MEMPHIS PLANNED DEVELOPMENT 100-YEAR FLOOD ELEV: 280.0 ± FEMA MAP PANEL NO: 310 G, 316 G FEMA MAP DATE: FEB. 6, 2013 OUTLINE PLAN P.D. 26-______ (FORMERLY P.D. 13-313, P.D. 08-326, P.D. 04-312, & P.D. 90-315 CC) JOB # 25-0216 “ ” “ ” ç ç “ ” “ ” · · · · · · · · · · 6800 Poplar Avenue, Suite 101 Memphis, TN 38138 901.761.2016 Fax: 901.763.2847 www.ReavesFirm.com Engineering Planning Landscape Architecture Land Surveying The Reaves Firm INCORPORATED MEMPHIS, TENNESSEE 250.34 ACRES DEVELOPER: STONECREST INVESTMENTS ENGINEER: THE REAVES FIRM JANUARY 2026 SCALE: N/A SHEET 6 OF 7 GALLERIA OF MEMPHIS PLANNED DEVELOPMENT 100-YEAR FLOOD ELEV: 280.0 ± FEMA MAP PANEL NO: 310 G, 316 G FEMA MAP DATE: FEB. 6, 2013 OUTLINE PLAN P.D. 26-______ (FORMERLY P.D. 13-313, P.D. 08-326, P.D. 04-312, & P.D. 90-315 CC) JOB # 25-0216 ENGINEER'S CERTIFICATE I hereby certify that this plat is true and correct, is in conformance with the design requirements of the Memphis and Shelby County Unified Development Code, the specific conditions imposed on this development, and takes into account all applicable federal, state and local building laws and regulations. By: (Seal) Date: . Tennessee License No. . LAND USE AND DEVELOPMENT SERVICES CERTIFICATE This final plat conforms with the planned development acted on by the Land Use Control Board on and approved by the Council of the City of Memphis on . By: . Date: . Zoning Administrator LUDS: . Date: . SURVEYOR'S CERTIFICATE I hereby certify that this is a category 1 survey and that the precision of the unadjusted survey is 1: 10,000 or greater; that this plat has been prepared by me or under my individual supervision and conforms with applicable state laws, the Memphis and Shelby County Unified Development Code, and specific conditions imposed on this development relating to the practice of surveying. By: (Seal) Date: . Tennessee License No. . NOTARY'S CERTIFICATE State of Tennessee County of Shelby Before me, the undersigned, a Notary Public in and for the said State and County at Memphis, duly commissioned and qualified, personally appeared with whom I am personally acquainted, and who upon his oath acknowledged himself to be the of , the within named bargainer, and that he executed the foregoing instrument for the purpose therein contained. In witness whereof, I have hereunto set my hand and affixed my notarial seal at my office this day of , 2026. Notary Public . My Commission Expires . OWNER'S CERTIFICATE We, , the undersigned owner of the property shown, hereby adopt this plat as our plan of development and dedicate the streets, right-of-way, and grant the easements as shown and/or described to public use forever. We certify that we are the owners of the said property in fee simple, duly authorized to act, and that said property is not encumbered by any taxes or mortgages which have become due and payable. Signature: . NOTARY'S CERTIFICATE State of Tennessee County of Shelby Before me, the undersigned, a Notary Public in and for the said State and County at Memphis, duly commissioned and qualified, personally appeared with whom I am personally acquainted, and who upon his oath acknowledged himself to be the of , the within named bargainer, and that he executed the foregoing instrument for the purpose therein contained. In witness whereof, I have hereunto set my hand and affixed my notarial seal at my office this day of , 2026. Notary Public . My Commission Expires . OWNER'S CERTIFICATE We, , the undersigned owner of the property shown, hereby adopt this plat as our plan of development and dedicate the streets, right-of-way, and grant the easements as shown and/or described to public use forever. We certify that we are the owners of the said property in fee simple, duly authorized to act, and that said property is not encumbered by any taxes or mortgages which have become due and payable. Signature: . NOTARY'S CERTIFICATE State of Tennessee County of Shelby Before me, the undersigned, a Notary Public in and for the said State and County at Memphis, duly commissioned and qualified, personally appeared with whom I am personally acquainted, and who upon his oath acknowledged himself to be the of , the within named bargainer, and that he executed the foregoing instrument for the purpose therein contained. In witness whereof, I have hereunto set my hand and affixed my notarial seal at my office this day of , 2026. Notary Public . My Commission Expires . OWNER'S CERTIFICATE We, , the undersigned owner of the property shown, hereby adopt this plat as our plan of development and dedicate the streets, right-of-way, and grant the easements as shown and/or described to public use forever. We certify that we are the owners of the said property in fee simple, duly authorized to act, and that said property is not encumbered by any taxes or mortgages which have become due and payable. Signature: . NOTARY'S CERTIFICATE State of Tennessee County of Shelby Before me, the undersigned, a Notary Public in and for the said State and County at Memphis, duly commissioned and qualified, personally appeared with whom I am personally acquainted, and who upon his oath acknowledged himself to be the of , the within named bargainer, and that he executed the foregoing instrument for the purpose therein contained. In witness whereof, I have hereunto set my hand and affixed my notarial seal at my office this day of , 2026. Notary Public . My Commission Expires . OWNER'S CERTIFICATE We, , the undersigned owner of the property shown, hereby adopt this plat as our plan of development and dedicate the streets, right-of-way, and grant the easements as shown and/or described to public use forever. We certify that we are the owners of the said property in fee simple, duly authorized to act, and that said property is not encumbered by any taxes or mortgages which have become due and payable. Signature: . 6800 Poplar Avenue, Suite 101 Memphis, TN 38138 901.761.2016 Fax: 901.763.2847 www.ReavesFirm.com Engineering Planning Landscape Architecture Land Surveying The Reaves Firm INCORPORATED MEMPHIS, TENNESSEE 250.34 ACRES DEVELOPER: STONECREST INVESTMENTS ENGINEER: THE REAVES FIRM JANUARY 2026 SCALE: N/A SHEET 7 OF 7 GALLERIA OF MEMPHIS PLANNED DEVELOPMENT 100-YEAR FLOOD ELEV: 280.0 ± FEMA MAP PANEL NO: 310 G, 316 G FEMA MAP DATE: FEB. 6, 2013 OUTLINE PLAN P.D. 26-______ (FORMERLY P.D. 13-313, P.D. 08-326, P.D. 04-312, & P.D. 90-315 CC) JOB # 25-0216 City Hall – 125 N. Main Street, Suite 468 – Memphis, Tennessee 38103 – (901) 636-6619 March 12, 2026 Christine Donhardt The Reaves Firm, Inc. 6800 Poplar Ave., Suite 101 Memphis, TN 38138 Sent via electronic mail to: cdonhardt@thereavesfirm.com Galleria of Memphis Planned Development Case Number: PD 2026-001 LUCB Recommendation: Approval with conditions Dear applicant, On Thursday, March 12, 202 6, t he Memphis and Shelby County Land Use Control Board recommended approval of your planned development amendment application for the Galleria of Memphis Planned Development, subject to the attached outline plan conditions. This application will be forwarded, for final action, to the Council of the City of Memphis. The Council will review your application in a committee meeting prior to voting on it in a public hearing. The applicant or the applicant’s representative(s) shall be in attendance at all meetings and hearings. It is the applicant’s responsibility to contact the City Council Records Office to determine when the application is scheduled to be heard at committee and in public session. The City Council Records Office may be reached at (901) 636-6792. If for some reason you choose to withdraw your application, a letter should be mailed to the Land Use and Development Services Department of the Division of Planning and Development at the address provided above or emailed to the address provided below. If you have questions regarding this matter, please feel free to contact me at (901) 636-6619 or via email at chloe.christion@memphistn.gov. Letter to Applicant PD 2026-001 Page 2 of 2 Respectfully, Chloe Christion Planner II Land Use and Development Services Division of Planning and Development Cc: Dianne Higgs – The Reaves Firm File Outline Plan Conditions – Revisions Proposed language is indicated in bold, underline; deletions are indicated in bold strikethrough Area A-3 I. Uses permitted: A. Hotel B. Any use permitted in Parcel I. A II. Bulk Regulations: A. The bulk regulations of the CMU-2 District shall apply in addition to the following: B. Maximum building height of five (5) stories. C. Maximum height of light standards 30 feet. III. Signs: A. The sign regulations of the CMU-2 District as found in UDC Section 4.9 shall apply. All other conditions of this planned development are recommended to be unaltered. CITY OF MEMPHIS COUNCIL AGENDA CHECK OFF SHEET ___________________________________________________________________________________ | ONE ORIGINAL | Planning & Development | ONLY STAPLED | DIVISION |TO DOCUMENTS| Planning & Zoning COMMITTEE: 03/24/2026 DATE PUBLIC SESSION: 04/14/2026 DATE ITEM (CHECK ONE) ORDINANCE X RESOLUTION X REQUEST FOR PUBLIC HEARING = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = ITEM DESCRIPTION: Resolution approving the request to close and vacate the public -right-of-way of a north -south public alley known as Litty Place that has an east -west stub at its midpoint heading eastward. , known as case number SAC 25-006 CASE NUMBER: SAC 25-006 LOCATION: East of Kansas St., south of W Georgia Ave., north of W Carolina Ave., and west of Florida St. COUNCIL DISTRICTS: District 7 and Super District 8 OWNER/APPLICANT: Charles Shoffner REPRESENTATIVES: Matthew Hudgins REQUEST: Close and vacate the public -right-of-way of a north -south public alley known as Litty Place that has an east - west stub at it's midpoint heading eastward and vacate public right-of-way of an east-west public alley AREA: +/-0.20 acres RECOMMENDATION: The Division of Planning and Development recommended Approval with conditions The Land Use Control Board recommended Approval with conditions RECOMMENDED COUNCIL ACTION: Public Hearing Not Required = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = PRIOR ACTION ON ITEM: (1) APPROVAL - (1) APPROVED (2) DENIED 03/09/2026 DATE (1) Land Use Control Board ORGANIZATION - (1) BOARD / COMMISSION (2) GOV’T. ENTITY (3) COUNCIL COMMITTEE = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = FUNDING: (2) REQUIRES CITY EXPENDITURE - (1) YES (2) NO $ AMOUNT OF EXPENDITURE $ REVENUE TO BE RECEIVED SOURCE AND AMOUNT OF FUNDS $ OPERATING BUDGET $ CIP PROJECT #_______________________________ $ FEDERAL/STATE/OTHER = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = ADMINISTRATIVE APPROVAL: DATE POSITION _____________________________________________ ____________ PLANNER _____________________________________________ ____________ DEPUTY ADMINISTRATOR _____________________________________________ ____________ ADMINISTRATOR _____________________________________________ ____________ DIRECTOR (JOINT APPROVAL) _____________________________________________ ____________ COMPTROLLER _____________________________________________ ____________ FINANCE DIRECTOR _____________________________________________ ____________ CITY ATTORNEY = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = _____________________________________________ ____________ CHIEF ADMINISTRATIVE OFFICER _____________________________________________ ____________ COMMITTEE CHAIRMAN 03/09/2027 03/16/2026 Memphis City Council Summary Sheet SAC 2025-006 RESOLUTION APPROVING THE REQUEST TO CLOSE AND VACATE THE PUBLIC -RIGHT-OF- WAY OF A NORTH -SOUTH PUBLIC ALLEY KNOWN AS LITTY PLACE THAT HAS AN EAST - WEST STUB AT ITS MIDPOINT HEADING EASTWARD. , KNOWN AS CASE NUMBER SAC 25- 006 • This item is a resolution with conditions to allow the above; and • This item may require a new public improvement contract. 1 LAND USE CONTROL BOARD RECOMMENDATION At its regular meeting on Thursday, February 12, 2026, the Memphis and Shelby County Land Use Control Board held a public hearing on the following application: CASE NUMBER: SAC 25-006 LOCATION: East of Kansas St., south of W Georgia Ave., north of W Carolina Ave., and west of Florida St. COUNCIL DISTRICT(S): District 7, Super District 8 – Positions 1, 2, and 3 OWNER/APPLICANT: Charles Shoffner REPRESENTATIVE: Matthew Hudgins REQUEST: Close and vacate the public-right-of-way of a north-south public alley known as Litty Place that has an east -west stub at it's midpoint heading eastward EXISTING ZONING: Bluffview Residential District – (R-B) AREA: 0.20 acres The following spoke in support: None The following spoke in opposition: None The Land Use Control Board reviewed the application and the staff report . A motion was made and seconded to recommend approval with conditions of the application. The motion passed by a unanimous vote of 10-0 on the consent agenda. Respectfully, Travian Smith Planner I Land Use and Development Services Division of Planning and Development Cc: Committee Members File 2 SAC 25-006 CONDITIONS 1. The applicant shall comply with all City standards to the satisfaction of the City Engineer and City Fire Department. 2. Provide easements for existing sanity sewers, drainage facilities, and other utilities or relocate at developer’s expense. 3. The applicant shall comply with all conditions of the closure within three years of the conditional approval of the closure by the Council of the City of Memphis. The Land Use Control Board may grant extensions to this date as Major Modifications as outlin ed in Section 9.8.6 of the UDC. Provide easements for existing sanitary sewers, drainage facilities, and other utilities or relocate at developer’s expense. 3 CLOSURE PLAT RESOLUTION RESOLUTION APPROVING THE REQUEST TO CLOSE AND VACATE THE PUBLIC -RIGHT-OF-WAY OF A NORTH -SOUTH PUBLIC ALLEY KNOWN AS LITTY PLACE THAT HAS AN EAST -WEST STUB AT ITS MIDPOINT HEADING EASTWARD. WHEREAS, the City of Memphis is the owner of real property known as the east-west public-right-of-way of a north-south public alley known as Litty Place in Memphis, Tennessee and being more particularly described as follows: Beginning at a point in the north line of West Carolina Avenue (65' R.O.W.), said point being located 137.50 feet east of the intersection of the north line of said West Carolina Avenue and the east line of Kansas Street (80' R.O.W.) and being located in the east line of the Charles W. Shoffner property recorded at Instrument No. 20023350; thence north 04 degrees 54 minutes 36 seconds east with the east line of said property recorded at Instrument No. 20023350 a distance of 341.19 feet to a point in the sou th line of West Georgia Avenue (65' R.O.W.) a distance of 137.50 feet east of the east line of Kansas Street; thence south 85 degrees 25 minutes 42 seconds east with the south line of said West Georgia Avenue a distance of 22.41 feet to a point in the west line of the Charles W. Shoffner property recorded at Instrument No. 20063264; thence south 04 degrees 44 minutes 05 seconds west with the west line of said property recorded at Instrument No. 20063264 and with the east line of Litty Place (12.5' Wide Public Alley) a distance of 161.63 feet to a point; thence south 85 degrees 15 minutes 51 seconds east with the south line of said property recorded at Instrument No. 20063264 and with the north line of a 20' Wide Public Alley a distance of 49.99 feet to a point; thence south 04 degrees 45 minutes 23 seconds west with the east end of said 20' Wide Public Alley a distance of 20.00 feet to the north line of the Charles W. Shoffner property recorded at Instrument No. 20021221; thence north 85 degrees 15 minutes 51 seconds west with the north line of said property recorded at Instrument No. 20021221 and with the south line of said 20' wide alley a distance of 49.98 feet; thence south 04 degrees 44 minutes 05 seconds west with the west line of said property recorded at Instrument No. 20021221 and with the east line of the aforesaid Litty Place a distance of 159.61 feet to a point in the north line of the aforesaid West Carolina Avenue; thence north 85 degrees 18 minutes 40 seconds west with the north line of said West Carolina Avenue a distance of 23.46 feet to the Point of Beginning and containing 8,825 square feet or 0.203 acres of land. WHEREAS, the City of Memphis has reviewed the recommendation of the Land Use Control Board and the report and recommendation of the Division of Planning and Development and desires to close the hereinabove described public right-of-way and it is deemed to be in the best interest of the City of Memphis that said public right-of-way be vacated, and revert to the abutting property owner(s); and WHEREAS, a public hearing in relation thereto was held before the Memphis and Shelby County Land Use Control Board on February 12, 2026, and said Board has submitted its findings and recommendation to the Council of the City of Memphis subject to the following conditions: 1. The applicant shall comply with all City standards to the satis faction of the City Engineer and City Fire Department. 2. Provide easements for existing sanity sewers, drainage facilities, and other utilities or relocate at developer’s expense. 3. The applicant shall comply with all conditions of the closure within three years of the conditional approval of the closure by the Council of the City of Memphis. Th e Land Use Control Board may grant extensions to this date as Major Modifications as outlined in Section 9.8.6 of the UDC. NOW THEREFORE BE IT RESOLVED , by the Council of the City of Memphis that the above described public right -of-way be and is hereby closed for public use, subject to the aforementioned conditions. BE IT FURTHER RESOLVED , that the Mayor is hereby authorized to execute all Quitclaim Deed(s) to the owners of the properties abutting on the above described public right-of- way, said Deeds not to be delivered until the conditions herein stated have been met by applicant. BE IT FURTHER RESOLVED , that a copy of this resolution be sent to the Lawyers Title Insurance Company, the Memphis Title Company, the Chicago Title Company, the Security Title Company and the Shelby County Property Assessor's Office. RIGHT-OF-WAY VACATION PLAT ATTEST: Cc: Division of Planning and Development – Land Use and Development Services City Engineering – Land Development City Real Estate Staff Writer: Travian Smith E-mail: Travian.Smith@memphistn.gov AGENDA ITEM: 2 L.U.C.B. MEETING: February 12, 2026 CASE NUMBER: SAC 2025-006 LOCATION: East of Kansas St., south of W Georgia Ave., north of W Carolina Ave., and west of Florida St. COUNCIL DISTRICT: District 6 and Super District 8 OWNER/APPLICANT: Charles Shoffner REPRESENTATIVE: Matthew Hudgins REQUEST: Close and vacate the public-right-of-way of a north-south public alley known as Litty Place that has an east-west stub at it's midpoint heading eastward EXISTING ZONING: Bluffview Residential District – (R-B) CONCLUSIONS 1. The applicant is responsible for the cost and construction of the curb, gutter, and sidewalk across the closure, as directed by the City Engineer. While Litty Place must remain open for fire access per the City Fire Department, the applicant shall install a standard curb cut to the satisfaction of the City Engineer at the applicant's expense. 2. Easements will be required to accommodate any existing public utilities, including electric, gas, water, CATV, telephone, sewer, drainage, etc. or their relocation at the applicant’s expense 3. The closure of the subject right -of-way will not have any undue or substantial effect upon the existing vehicular and pedestrian traffic flow of the surrounding area. CONSISTENCY WITH MEMPHIS 3.0 The Memphis 3.0 General Plan is not applicable as it does not address the closure of alleys. RECOMMENDATION: Approval with conditions Staff Report February 12, 2026 SAC 2025-006 Page 2 2 LOCATION MAP Subject right-of-way located within the pink circle SUBJECT RIGHT-OF-WAY Staff Report February 12, 2026 SAC 2025-006 Page 3 3 PUBLIC NOTICE VICINITY MAP Subject right-of-way highlighted in yellow PUBLIC NOTICE DETAILS In accordance with Sub-Section 9.3.4A of the Unified Development Code, a notice of public hearing is required to be mailed. A total of 333 notices were mailed on December 18, 2025, see page 13 of this report for a copy of said notice. Additionally, a total of two signs were posted, one at each end of the subject right-of-way, see page 14 of this report for a copy of the sign affidavit. Staff Report February 12, 2026 SAC 2025-006 Page 4 4 AERIAL Subject right-of-way outlined in yellow, imagery from 2021 Staff Report February 12, 2026 SAC 2025-006 Page 5 5 ZONING MAP Subject right-of-way highlighted in yellow Staff Report February 12, 2026 SAC 2025-006 Page 6 6 LAND USE MAP Subject right-of-way indicated by a red star Staff Report February 12, 2026 SAC 2025-006 Page 7 7 SITE PHOTOS View of subject right-of-way from Carolina Avenue looking North View of subject right-of-way from Georgia Avenue looking South Staff Report February 12, 2026 SAC 2025-006 Page 8 8 RIGHT-OF-WAY VACATION PLAT Staff Report February 12, 2026 SAC 2025-006 Page 9 9 LEGAL DESCRIPTION Litty Place ROW Closure Description Description of the City of Memphis property located in Block 88 of Ward 2 in Memphis, Shelby County, Tennessee and being part of alleys in Block 26, Fort Pickering Subdivision (Unrecorded): Beginning at a point in the north line of West Carolina Avenue (65' R.O.W.), said point being located 137.50 feet east of the intersection of the north line of said West Carolina Avenue and the east line of Kansas Street (80' R.O.W.) and being located in the east line of the Charles W. Shoffner property recorded at Instrument No. 20023350; thence north 04 degrees 54 minutes 36 seconds east with the east line of said property recorded at Instrument No. 20023350 a distance of 341.19 feet to a point in the south line of West Georgia Avenue (65' R.O.W.) a distance of 137.50 feet east of the east line of Kansas Street; thence south 85 degrees 25 minutes 42 seconds east with the south line of said West Georgia Avenue a distance of 22.41 feet to a point in the west line of the Charles W. Shoffner property recorded at Instrument No. 20063264; thence south 04 degrees 44 minutes 05 seconds west with the west line of said property recorded at Instrument No. 20063264 and with the east line of Litty Place (12.5' Wide Public Alley) a distance of 161.63 feet to a point; thence south 85 degrees 15 minutes 51 seconds east with the south line of said property recorded at Instrument No. 20063264 and with the north line of a 20' Wide Public Alley a distance of 49.99 feet to a point; thence south 04 degrees 45 minutes 23 seconds west with the east end of said 20' Wide Public Alley a distance of 20.00 feet to the north line of the Charles W. Shoffner property recorded at Instrument No. 20021221; thence north 85 degrees 15 minutes 51 seconds west with the north line of said property recorded at Instrument No. 20021221 and with the south line of said 20' wide alley a distance of 49.98 feet; thence south 04 degrees 44 minutes 05 seconds west with the west line of said property recorded at Instrument No. 20021221 and with the east line of the aforesaid Litty Place a distance of 159.61 feet to a point in the north line of the aforesaid West Carolina Avenue; thence north 85 degrees 18 minutes 40 seconds west with the north line of said West Carolina Avenue a distance of 23.46 feet to the Point of Beginning and containing 8,825 square feet or 0.203 acres of land. Staff Report February 12, 2026 SAC 2025-006 Page 10 10 CASE REVIEW Request The request is to close and vacate the public-right-of-way of a north-south public alley known as Litty Place that has an east-west stub at its midpoint heading eastward. Site Details Address: 0 Litty Place Area: +/-8,800 square feet (.20 acres) Description: The subject right -of-way is a +/ -20-foot wide and +/ -341 long east -west public alley for a total area of 8,800 square feet within the block bounded by W Carolina and Georgia Avenue. The subject right-of-way is located in between three parcels (002088 00001C, 002088 00002C, and 002088 00006) all of which are owned by Charles Shoffner. The zoning of the area is Bluffview Residential District – (R-B) and is surrounded by a mixture of land uses made up of industrial, residential single-family, and vacant lots. Analysis The applicant is responsible for the cost and construction of the curb, gutter, and sidewalk across the closure, as directed by the City Engineer. While Litty Place must remain open for fire access per the City Fire Department, the applicant shall install a standard curb cut to the satisfaction of the City Engineer at the applicant's expense. Easements will be required to accommodate any existing public utilities, including electric, gas, water, CATV, telephone, sewer, drainage, etc. or their relocation at the applicant’s expense The closure of the subject right-of-way will not have any undue or substantial effect upon the existing vehicular and pedestrian traffic flow of the surrounding area. RECOMMENDATION Staff recommends approval with conditions. Conditions 1. The applicant shall comply with all City standards to the satisfaction of the City Engineer and City Fire Department. 2. Provide easements for existing sanity sewers, drainage facilities, and other utilities or relocate at developer’s expense. 3. The applicant shall comply with all conditions of the closure within three years of the conditional approval of the closure by the Council of the City of Memphis. The Land Use Control Board may grant extensions to this date as Major Modifications as outlined in Section 9.8.6 of the UDC. Staff Report February 12, 2026 SAC 2025-006 Page 11 11 DEPARTMENTAL COMMENTS The following comments were provided by agencies to which this application was referred: City Engineer: CASE 4: * SAC-25-006 NAME: ROW closure of approx. 8800 sq ft of Litty Place at Georgia Ave Basin/Lot/CD: Fort Pickering, 1-N/ 0.26ac/6 1. Standard Public Improvement Contract or Right-Of-Way Permit as required in Section 5.5.5 of the Unified Development Code. Sewers: 2. There is an existing 8” sewer line in Alley. Dedicate minimum 15’ permanent sewer easement for the sewer. Street Closures: 3. Provide easements for existing sanitary sewers, drainage facilities and other utilities or relocate at developer's expense. 4. City sanitary sewers/drainage facilities are located within the proposed closure area. 5. The applicant shall provide for the construction of curb, gutter and sidewalk across the closure as required by the City Engineer. If the City Engineer approves access, the applicant shall construct a City Standard curb cut across the closure, all to the satisfaction of the City Engineer, and at the applicant's expense. The applicant shall enter into a Standard Improvement Contract or obtain a Right of Way permit from the City Engineer to cover the above required construction work. 6. The applicant shall comply with all conditions of the closure within 3 years of the conditional approval of the closure by the City Council. 7. Adequate queuing spaces in accordance with the current ordinance shall be provided between the street right-of-way line and any proposed gate/guardhouse/card reader. 8. Adequate maneuvering room shall be provided between the right-of-way and the gate/guardhouse/card reader for vehicles. 9. Required landscaping shall not be placed on sewer or drainage easements. County Engineer: No comments received. Staff Report February 12, 2026 SAC 2025-006 Page 12 12 City Fire Division: 1. Litty Place is required to be maintained for Fire Department access. 2. Where security gates are installed that affect required fire apparatus access roads, they shall comply with section 503.6 (as amended). 3. All design and construction shall comply with the 2021 edition of the International Fire Code with local amendments and referenced standards. 4. Fire apparatus access shall comply with section 503. 5. Where security gates are installed that affect required fire apparatus access roads, they shall comply with section 503.6. 6. Fire protection water supplies (including fire hydrants) shall comply with section 507. 7. Where fire apparatus access roads or a water supply for fire protection are required to be installed, such protection shall be installed and made serviceable prior to and during the time of construction except when approved alternate methods of protection are provided. 8. IFC 510 In-building two-way emergency responder communication coverage shall be provided in all new and existing buildings. Buildings and structures that cannot support the required level of coverage shall be equipped with systems and components to enhance signals and achieve the required level of communication coverage. 9. A detailed plans review will be conducted by the Memphis Fire Prevention Bureau upon receipt of complete construction documents. Plans shall be submitted to the Shelby County Office of Code Enforcement. County Fire Division: No comments received. City Real Estate: No comments received. County Health Department: No comments received. Shelby County Schools: No comments received. Construction Code Enforcement: No comments received. Memphis Light, Gas and Water: No comments received. Office of Sustainability and Resilience: No comments received. Office of Comprehensive Planning: No comments received. Staff Report February 12, 2026 SAC 2025-006 Page 13 13 MAILED PUBLIC NOTICE Staff Report February 12, 2026 SAC 2025-006 Page 14 14 SIGN AFFIDAVIT + Staff Report February 12, 2026 SAC 2025-006 Page 15 15 APPLICATION Staff Report February 12, 2026 SAC 2025-006 Page 16 16 Staff Report February 12, 2026 SAC 2025-006 Page 17 17 Staff Report February 12, 2026 SAC 2025-006 Page 18 18 OWNER AFFIDAVIT Staff Report February 12, 2026 SAC 2025-006 Page 19 19 LETTER OF INTENT Staff Report February 12, 2026 SAC 2025-006 Page 20 20 LETTERS RECEIVED No letters received at the time of completion of this report. East Service Center: 6465 Mullins Station Rd; Memphis, Tennessee 38134 Downtown Service Center: 125 N. Main Street; Memphis, T ennessee 38103 website: www.develop901.com Memphis and Shelby County Division of Planning and Development Record Summary for Street and Alley Closure (Right of Way Vacation ) Record Detail Information Record Type: Street and Alley Closure (Right of Way Vacation) Record Status: Pending Opened Date: November 19, 2025 Record Number: SAC 2025-006 Record Name: Litty Place Alley Closure Expiration Date: Description of Work: Requesting the closure of an unused and neglected alley. Charles Shoffner (Applicant) is the owner of all adjacent properties. Parent Record Number: Address: LITTY PLACE, TN Owner Information Primary Owner Name Owner Address Owner Phone N Data Fields PREAPPLICA TION MEETING Name of DPD Planner Nabanita Nira Date of Meeting 08/22/2025 Pre-application Meeting Type Email GENERAL INFORMATION Name of Street where closure will begin W. Carolina Ave. Name of Street where closure will end W. Georgia Ave. What is the reason for the street closure? Unused / neglected Alley What is the total area of the right-of-way being closed? 8825 What is the overall length of the street closure? 341.19 Name of Street/Alley/ROW Litty Place Page 1 of 3 SAC 2025-006 GENERAL INFORMATION Is this application in response to a citation from Construction Code Enforcement or Zoning Letter? No If yes, please provide additional information - Is this application a time extension? No RELATED CASE INFORMATION Previous Case Numbers - GIS INFORMA TION Case Layer - Central Business Improvement District No Class - Downtown Fire District No Historic District - Land Use - Municipality - Overlay/Special Purpose District - Zoning - State Route - Lot - Subdivision - Planned Development District - Wellhead Protection Overlay District No County Commission District - City Council District - City Council Super District - Data Tables Property Owners Property Address: 92 W. Carolina Ave. Property Owner Name: Charles W Shoffner Mailing Address (if different than property address): 612 S. Main St. Memphis, TN 38103 Contact Information Page 2 of 3 SAC 2025-006 CHARLES SHOFFNER (901)483-2361 ADJACENT PROPERTY OWNER OF RECORD Name Address Phone Contact Type CHARLES SHOFFNER - APPLICANT Name Address Phone Contact Type LARRY ASTIN (901)683-9114 ARCHITECT / ENGINEER / SUR VEYOR Name Address Phone Contact Type MATTHEW HUDGINS (614)307-9730 REPRESENT ATIVE Name Address Phone Contact Type Fee Information Date AssessedBalanceStatusFeesQuantityFee ItemInvoice # 11 /19/20250.00INVOICED400.001Right of Way Vacation/Closure Fee 1691619 11/19/20250.00INVOICED0.001Credit Card Use Fee (.026 x fee) 1691598 Total Fee Invoiced: $400.00 Total Balance: $0.00 Payment Information Payment Amount Method of Payment Fund T ransfer$400.00 Page 3 of 3 SAC 2025-006 Litty Place ROW Closure Description Description of the City of Memphis property located in Block 88 of Ward 2 in Memphis, Shelby County, Tennessee and being part of alleys in Block 26, Fort Pickering Subdivision (Unrecorded): Beginning at a point in the north line of West Carolina Avenue (65' R.O.W.), said point being located 137.50 feet east of the intersection of the north line of said West Carolina Avenue and the east line of Kansas Street (80' R.O.W.) and being located in the east line of the Charles W. Shoffner property recorded at Instrument No. 20023350; thence north 04 degrees 54 minutes 36 seconds east with the east line of said property recorded at Instrument No. 20023350 a distance of 341.19 feet to a point in the south line of West Georgia Avenue (65' R.O.W.) a distance of 137.50 feet east of the east line of Kansas Street; thence south 85 degrees 25 minutes 42 seconds east with the south line of said West Georgia Avenue a distance of 22.41 feet to a point in the west line of the Charles W. Shoffner property recorded at Instrument No. 20063264; thence south 04 degrees 44 minutes 05 seconds west with the west line of said property recorded at Instrument No. 20063264 and with the east line of Litty Place (12.5' Wide Public Alley) a distance of 161.63 feet to a point; thence south 85 degrees 15 minutes 51 seconds east with the south line of said property recorded at Instrument No. 20063264 and with the north line of a 20' Wide Public Alley a distance of 49.99 feet to a point; thence south 04 degrees 45 minutes 23 seconds west with the east end of said 20' Wide Public Alley a distance of 20.00 feet to the north line of the Charles W. Shoffner property recorded at Instrument No. 20021221; thence north 85 degrees 15 minutes 51 seconds west with the north line of said property recorded at Instrument No. 20021221 and with the south line of said 20' wide alley a distance of 49.98 feet; thence south 04 degrees 44 minutes 05 seconds west with the west line of said property recorded at Instrument No. 20021221 and with the east line of the aforesaid Litty Place a distance of 159.61 feet to a point in the north line of the aforesaid West Carolina Avenue; thence north 85 degrees 18 minutes 40 seconds west with the north line of said West Carolina Avenue a distance of 23.46 feet to the Point of Beginning and containing 8,825 square feet or 0.203 acres of land. 19 November 2025 Memphis and Shelby County Division of Planning and Development 125 N. Main St. #477 Memphis, TN 38103 Division of Planning and Development, Please see the attached documents for the requested alley closure at 0 Litty Place. The alley at Litty Place was has been unused and informally abandoned for some time now. As the property owner of all adjacent parcels to the alley in question, I am requesting that the right of way be formally vacated and deeded over to the parcels described in the attached document to this application. Sincerely, Chuck Sho� ner Realty Investment Group LLC 901.483.2361 LETTER OF INTENT -----MEMPHIS AND== DIVISION OF PLANNING SHELBY COUNTY.I AND DEVELOPMENT City Hall - 125 N. Main Street, Suite 468 - Memphis, Tennessee 38103 - (901) 636-6619 Property Owner's Affidavit Memphis and Shelby County Unified Development Code Section 12.3.1 OWNER: Includes the holder of legal title as well as holders of any equitable interest, such as trust beneficiaries, contract purchasers, option holders, lessees under leases having an unexpired term of at least ten years, and the like. Whenever a statement of ownership is required by the Memphis and Shelby County Unified Development Code, full disclosure of all legal and equitable interest in the property is required. Memphis and Shelby County Unified Development Code Section 12.3.1. I, Charles Shoffner (Print Name) dnL ~~ate that I have read the definition of (Sign Name) 7 • "Owner" as outlined in the Memphis and Shelby County Unified Development Code Section 12.3.1 and hereby state that (select applicable box): ~ I am the owner of record as shown on the current tax rolls of the county Assessor of Property; the mortgage holder of record as shown in the mortgage records of the county Register of Deeds; purchaser under a land contract; a mortgagee or vendee in possession; or I have a freehold or lesser estate in the premises D I have charge, care or control of the premises as trustee, agent, executor, administrator, assignee, receiver, guardian or lessee (and have included documentation with this affidavit) of the property located at 92 W. Carolina, 78 W. Caroliona, 0 Georgia, 0 Carolina, 0 Carolina and further identified by Assessor's Parcel Number 00208800001 c, 002088oooosc, 002088000002c, 00208800006, for which an application is being made to the Division of Planning and Development. 00208800006 Subscribed and sworn to (or affirmed) before mj.~;.•~~'\ day of August in the year of 2025 §"l o~ •• ~ i f s~"1ss~~ \ \ My Commission Expires: ~ IDcuv i \ "'~~~"'"~~ j i re February 29, 2028 _JJ_ ~ •• ~\)'o\; _ •• ~ ~ ~ Signature of Notary Public \ ············•fW~~ My Commission Expires ~,,,, SHB.6'< ~,,-.: ~ ~ :,,,,,,,,1111\\\\~~ co,,,M,ss~ 'C.,... City Hall – 125 N. Main Street, Suite 468 – Memphis, Tennessee 38103 – (901) 636-6619 February 13, 2026 Charles Shoffner Realty Investment Group LLC. Sent via electronic mail to: chuckshoffner@gmail.com Case Number: SAC 2026-006 LUCB Recommendation: Approval with conditions Dear applicant, On Thursday, February 12, 20 26, t he Memphis and Shelby County Land Use Control Board recommended approval of your right-of-way vacation application to close and vacate the public- right-of-way of a north-south public alley known as Litty Place that has an east -west stub at it ’s midpoint heading eastward, subject to the following conditions: 1. The applicant shall comply with all City standards to the satisfaction of the City Engineer and City Fire Department. 2. Provide easement s for e xisting sanity sewers , drainage facilities, and other utilities or relocate at developer’s expense. 3. The applicant shall comply with all conditions of the closure wit hin three years of the conditional approval of the closure by the Council of the City of Memphis. The L and Use Control Board may grant extensions to this date as Major Modifications as outlined in Section 9.8.6 of the UDC. The application will be forwarded, for final action, to the Council of the City of Memphis. The Council will review your application in a committee meeting prior to vot ing on it in a public hearing. The applicant or the applicant’s representative(s) shall be in attendance at all meetings and hearings. It is the applicant’s responsibility to contact the City Council Records Office to determine when the application is scheduled to be heard at co mmittee and in public session. The City Council Records Office may be reached at (901) 636-6792. If for some reason you choose to withdraw your application, a letter should be mailed to the Land Use and Development Services Department of the Division of Planning and Development at the address provided above or emailed to the address provided below. Letter to Applicant SAC 2026-006 Page 2 of 2 If you have questions regarding this matter, please feel free to contact me at (901) 636-6619 or via email at Travian.Smith@memphistn.gov. Respectfully, Travian Smith Planner I Land Use and Development Services Division of Planning and Development Cc: Charles Shoffner Cc: Matthew Hudgins File Memphis City Council Summary Sheet SUP 2026-001 RESOLUTION PURSUANT TO CHAPTER 9.6 OF THE MEMPHIS AND SHELBY COUNTY UNIFIED DEVELOPMENT CODE APPROVING A SPECIAL USE PERMIT AT THE SUBJECT PROPERTY LOCATED AT 3575 EMERALD STREET, KNOWN AS CASE NUMBER SUP 2026-001 • This item is a resolution with conditions for a special use permit to allow vehicle sales; and • The item may require future public improvement contracts. 1 LAND USE CONTROL BOARD RECOMMENDATION At its regular meeting on Thursday, February 12, 2026, the Memphis and Shelby County Land Use Control Board held a public hearing on the following application: CASE NUMBER: SUP 2026-001 LOCATION: 3575 Emerald Street COUNCIL DISTRICT(S): District 4 and Super District 8 – Positions 1, 2, and 3 OWNER/APPLICANT: Dennis Small - Small’s Automotive LLC REPRESENTATIVE: Brian Bacchus – Bacchus Urban Design Group (BUD) REQUEST: To allow a commercial surface parking lot for a period not to exceed fifteen (15) years EXISTING ZONING: Commercial Mixed Use—1 (CMU-1) AREA: +/-22,172 square feet The following spoke in support: None The following spoke in opposition: None The Land Use Control Board reviewed the application and the staff report . A motion was made and seconded to recommend approval with conditions. The motion passed by a vote of 9-0 on the consent agenda. Respectfully, Cc: Committee Members File 2 SUP 2026-001 CONDITIONS 1. Vehicle repair and used tire sales are prohibited. 2. Outdoor display and sales shall be limited to the requirements of UDC Sub-Section 4.8.4A. 3. All street frontages must have streetscape installed or an equivalent alternative approved by the Division of Planning and Development. 4. The dumpster location and screening shall meet the requirements of UDC Sub-Section 4.6.8B. 5. All parking and vehicle use areas shall be surfaced and all parking spaces shall be painted with striping. 6. The applicant shall submit a final site plan and landscape plan subject to administrative review and approval by the Division of Planning and Development 3 COCEPT PLAN RESOLUTION PURSUANT TO CHAPTER 9.6 OF THE MEMPHIS AND SHELBY COUNTY UNIFIED DEVELOPMENT CODE APPROVING A SPECIAL USE PERMIT AT THE SUBJECT PROPERTY LOCATED AT 3575 EMERALD STREET, KNOWN AS CASE NUMBER SUP 2026- 001 WHEREAS, Chapter 9.6 of the Memphis and Shelby County Unified Development Code, being a section of the Joint Ordinance Resolution No. 5367, dated August 10, 2010, authorizes the Council of the City of Memphis to grant a special use permit for certain stated purposes in the various zoning districts; and WHEREAS, Dennis Small - Small’s Automotive LLC filed an application with the Memphis and Shelby County Division of Planning and Development to allow vehicle sales; and WHEREAS, the Division of Planning and Development has received and reviewed the application in accordance with procedures, objectives, and standards for special use permits as set forth in Chapter 9.6 with regard to the proposed development's impacts upon surrounding propertie s, availability of public facilities, both external and internal circulation, land use compatibility, and that the design and amenities are consistent with the public interest; and has submitted its findings and recommendation concerning the above considerations to the Land Use Control Board; and WHEREAS, a public hearing in relation thereto was held before the Memphis and Shelby County Land Use Control Board on February 12, 20 26, and said Board has submitted its findings and recommendation concerning the above considerations to the Council of the City of Memphis; and WHEREAS, the Council of the City of Memphis has reviewed the aforementioned application pursuant to Tennessee Code Annotated Section 13 -4-202(B)(2)(B)(iii) and has determined that said development is consistent with the Memphis 3.0 General Plan; and WHEREAS, the Council of the City of Memphis has reviewed the recommendation of the Land Use Control Board and the report and recommendation of the Division of Planning and Development and has determined that said development meets the objectives, standards and criteria for a special use permit, and said development is consistent with the public interests. NOW, THEREFORE, BE IT RESOLVED, BY THE COUNCIL OF THE CITY OF MEMPHIS, that, pursuant to Chapter 9.6 of the Memphis and Shelby County Unified Development Code, a special use permit is hereby granted for the request use in accordance with the attached conditions. BE IT FURTHER RESOLVED , that this permit merely authorizes the filing of applications to acquire a Certificate of Use and Occupancy, or a Building Permit, and other required permits and approvals, provided that no such Certificate of Use and Occupancy shall be granted until all conditions imposed by the Council of the City of Memphis have been met. BE IT FURTHER RESOLVED , that this Resolution take effect from and after the date it shall have been passed by this Council of the City of Memphis, and become effective as otherwise provided by law, and thereafter shall be treated as in full force and effect by virtue of passage thereof by the Council of the City of Memphis, the public welfare requiring same. CONDITIONS 1. Vehicle repair and used tire sales are prohibited. 2. Outdoor display and sales shall be limited to the requirements of UDC Sub-Section 4.8.4A. 3. All street frontages must have streetscape installed or an equivalent alternative approved by the Division of Planning and Development. 4. The dumpster location and screening shall meet the requirements of UDC Sub-Section 4.6.8B. 5. All parking and vehicle use areas shall be surfaced and all parking spaces shall be painted with striping. 6. The applicant shall submit a final site plan and landscape plan subject to administrative review and approval by the Division of Planning and Development. CONCEPT PLAN ATTEST: CC: Division of Planning and Development – Land Use and Development Services – Office of Construction Enforcement Staff Writer: Mahsan Ostadnia E-mail: mahsan.ostadnia@memphistn.gov AGENDA ITEM: 11 L.U.C.B. MEETING: February 12, 2026 CASE NUMBER: SUP 2026-001 LOCATION: 3575 Emerald Street COUNCIL DISTRICT: District 4 and Super District 8 – Positions 1, 2, and 3 OWNER/APPLICANT: Dennis Small - Small’s Automotive LLC REPRESENTATIVE: Brian Bacchus – Bacchus Urban Design Group (BUD) REQUEST: Special use permit to allow vehicle sales EXISTING ZONING: Commercial Mixed Use—1 (CMU-1) CONCLUSIONS 1. The applicant is requesting a Special Use Permit for motor vehicle sales, limited to used vehicles at 3575 Emerald Street, located on Lots 6 and 7 of Emerald Square Subdivision and zoned CMU-1. The site includes an existing 2,800 -square-foot building const ructed in 1977 and is surrounded by mixed commercial, institutional, office, and residential uses. 2. The property previously functioned as a vehicle wash and automotive service facility, a permitted use in the CMU-1 district. The proposal retains service use and introduces used vehicle sales, subject to approval of a Special Use Permit . The submitted vehicle display concept primarily arranged along the north, west, and south portions of the property. The layout maintains dedicated access to the service and carwash bays and depicts one -way internal circulation with defined maneuvering ar eas to accommodate both vehicle display and service activities. 3. The subject property includes two adjacent lots, each approximately 185 feet wide by 60 feet deep, resulting in a combined site depth of approximately 120 feet. Emerald Street is identified as a 60-foot right- of-way, and access is provided through a gated entrance with paved apron frontage. A 10 -foot drainage easement is located along the southern property line. Additional site features shown include existing fencing, concrete and asphalt paving, and utility infrastructure serving the property. 4. The granting of this special use permit will not cause substantial detriment to the public good, nor will it substantially impair the intent and purpose of an adopted plan or the Unified Development Code (UDC), nor will it be injurious to the neighborhood or the general welfare, and it will be in harmony with the purpose and intent of the UDC. CONSISTENCY WITH MEMPHIS 3.0 This proposal is consistent with the Memphis 3.0 General Plan per the land use decision criteria. See further analysis on pages 19-21 of this report. RECOMMENDATION: Approval with conditions Staff Report February 12, 2026 SUP 2026-001 Page 2 2 LOCATION MAP Subject property located within the pink circle. SUBJECT PROPERTY Staff Report February 12, 2026 SUP 2026-001 Page 3 3 PUBLIC NOTICE VICINITY MAP Subject property highlighted in yellow. PUBLIC NOTICE DETAILS In accordance with Sub-Section 9.3.4A of the Unified Development Code, a notice of public hearing is required to be mailed and signage posted. A total of 97 notices were mailed on January 1 3, 2026, see page 22 of this report for a copy of said notice . Additionally, one sign was posted at the subject property, see page s 23-24 of this report for a copy of the sign affidavit. NEIGHBORHOOD MEETING The meeting was held at 6:00 to 7:00 PM on Thursday, February 5, 2026, at 3575 Emerald Street, Memphis, TN 38115. See pages 25-26 of this report for a copy of the neighborhood meeting summary. Staff Report February 12, 2026 SUP 2026-001 Page 4 4 EMERALD SQUARE SUBDIVISION (1976) (PLAT BOOK 65 PAGE 5) Subject property highlighted in yellow. Staff Report February 12, 2026 SUP 2026-001 Page 5 5 AERIAL Subject property outlined in yellow. Staff Report February 12, 2026 SUP 2026-001 Page 6 6 ZONING MAP Subject property highlighted in yellow. Staff Report February 12, 2026 SUP 2026-001 Page 7 7 LAND USE MAP Subject property indicated by a yellow star. Staff Report February 12, 2026 SUP 2026-001 Page 8 8 SITE PHOTOS View of subject property from Emerald Street (front). View of subject property from Emerald Street (west). View of subject property from above. Staff Report February 12, 2026 SUP 2026-001 Page 9 9 View of subject property from above. View of subject property from above. Staff Report February 12, 2026 SUP 2026-001 Page 10 10 CONCEPT PLAN Staff Report February 12, 2026 SUP 2026-001 Page 11 11 SITE PLAN Staff Report February 12, 2026 SUP 2026-001 Page 12 12 SITE PLAN – MAGNIFIED Staff Report February 12, 2026 SUP 2026-001 Page 13 13 CASE REVIEW Request The request is a special use permit to allow vehicle sales. Approval Criteria Staff agrees the approval criteria in regard to special use permits as set out in Section 9. 6.9 of the Unified Development Code are met. 9.6.9 Approval Criteria No special use permit or planned development shall be approved unless the following findings are made concerning the application: 9.6.9A The project will not have a substantial or undue adverse effect upon adjacent property, the character of the neighborhood, traffic conditions, parking, utility facilities and other matters affecting the public health, safety, and general welfare. 9.6.9B The project will be constructed, arranged and operated so as to be compatible with the immediate vicinity and not interfere with the development and use of adjacent property in accordance with the applicable district regulations. 9.6.9C The project will be served adequately by essential public facilities and services such as streets, parking, drainage, refuse disposal, fire protection and emergency services, water and sewers; or that the applicant will provide adequately for such services. 9.6.9D The project will not result in the destruction, loss or damage of any feature determined by the governing bodies to be of significant natural, scenic or historic importance. 9.6.9E The project complies with all additional standards imposed on it by any particular provisions authorizing such use. 9.6.9F The request will not adversely affect any plans to be considered (see Chapter 1.9), or violate the character of existing standards for development of the adjacent properties. 9.6.9G The governing bodies may impose conditions to minimize adverse effects on the neighborhood or on public facilities, and to ensure compatibility of the proposed development with surrounding properties, uses, and the purpose and intent of this development code. 9.6.9H Any decision to deny a special use permit request to place, construct, or modify personal wireless service facilities shall be in writing and supported by substantial evidence contained in a written record, per the Telecommunications Act of 1996, 47 USC 3 32(c)(7)(B)(iii). The review body may not take into account any environmental or health concerns. Site Details Address: 3575 Emerald Street Parcel ID: 074102 00092 Area: +/-22,172 square feet Staff Report February 12, 2026 SUP 2026-001 Page 14 14 Description: The subject property is known as Lot 6 and 7 of Emerald Square Subdivision a zoning of Commercial Mixed-Use- 1 (CMU-1). Per the Assessor’s website, the principal structure on the site was built in 1977 with a ground floor area of 2,800 square feet and the surrounding land uses are a mixture of commercial, institutional, office, and single-family lots. Additionally, this lot has one street frontage. Site Plan Review The subject property includes Lots 6 and 7 of Emerald Square Subdivision, located along Emerald Street. Each lot is approximately 185 feet wide by 60 feet deep, creating a combined site depth of roughly 120 feet. Emerald Street is identified as a 60 -foot r ight-of-way, and the site is served by paved apron access along the street frontage. A 10-foot drainage easement is located along the southern property line. The site is developed with an existing block building ( #3575) and associated carwash bays, with co ncrete apron areas surrounding the structures for vehicular circulation and service access. Vehicular access to the site is provided from Emerald Street through a gated entrance, with paved internal circulation throughout the property. The existing building extends approximately 185 feet in width, with service and carwash bays oriented toward the interior apron area. The submitted concept plan depicts one-way internal circulation and clearly defined maneuvering areas designed to accommodate vehicle service and display activities while avoiding backing movements onto Emerald Street. The vehicle sales display concept plan illustrates approximately 25 on -site vehicle display spaces distributed along the perimeter and interior paved apron areas of Lots 6 and 7. Display spaces are primarily located along the north, west, and south edges o f the site. The plan also maintains dedicated service access to the existing building and carwash bays. Additional site features shown include concrete and asphalt paving, fencing along portions of the property boundary, utility elements such as water meters, sewer manholes, and power poles, and apron areas along the frontage. Prior to final site plan approval, the applicant shall revise the parking layout to resolve the overlap of vehicle display within parking spaces 21/22 and 18/19. All parking spaces, drive aisles, and maneuvering areas shall be clearly dimensioned and shown to scale to demonstrate compliance with the parking design standards of UDC Sub-Section 4.5.5A. The final site plan shall also include additional landscaping in the area identified on the concept plan to enhance site appearance and buffering. Analysis The applicant is requesting a Special Use Permit for motor vehicle sales, limited to used vehicles at 3575 Emerald Street, located on Lots 6 and 7 of Emerald Square Subdivision and zoned CMU -1. The site includes an existing 2,800-square-foot building const ructed in 1977 and is surrounded by mixed commercial, institutional, office, and residential uses. The property previously functioned as a vehicle wash and automotive service facility, a permitted use in the CMU-1 district. The proposal retains service use and introduces used vehicle sales, subject to approval of a Special Use Permit. The submitted vehicle display concept primarily arranged along the north, west, and south portions of the property. The layout maintains dedicated access to the service and carwash bays and depicts one-way internal circulation with defined maneuvering areas to accommodate both vehicle display and service Staff Report February 12, 2026 SUP 2026-001 Page 15 15 activities. The subject property includes two adjacent lots, each approximately 185 feet wide by 60 feet deep, resulting in a combined site depth of approximately 120 feet. Emerald Street is identified as a 60 -foot right-of-way, and access is provided through a gated entrance with paved apron frontage. A 10-foot drainage easement is located along the southern property line. Additional site features shown include existing fencing, concrete and asphalt paving, and utility infrastructure serving the property. The granting of this special use permit will not cause substantial detriment to the public good, nor will it substantially impair the intent and purpose of an adopted plan or the Unified Development Code (UDC), nor will it be injurious to the neighborhood or the general welfare, and it will be in harmony with the purpose and intent of the UDC. RECOMMENDATION Staff recommends approval with conditions. Conditions 1. Vehicle repair and used tire sales are prohibited. 2. Outdoor display and sales shall be limited to the requirements of UDC Sub-Section 4.8.4A. 3. All street frontages must have streetscape installed or an equivalent alternative approved by the Division of Planning and Development. 4. The dumpster location and screening shall meet the requirements of UDC Sub-Section 4.6.8B. 5. All parking and vehicle use areas shall be surfaced and all parking spaces shall be painted with striping. 6. The applicant shall submit a final site plan and landscape plan subject to administrative review and approval by the Division of Planning and Development Staff Report February 12, 2026 SUP 2026-001 Page 16 16 DEPARTMENTAL COMMENTS The following comments were provided by agencies to which this application was referred: City Engineer: See page 17. County Engineer: No comments received. City Fire Division: See page 18. County Fire Division: No comments received. City Real Estate: No comments received. County Health Department: No comments received. Shelby County Schools: No comments received. Construction Code Enforcement: No comments received. Memphis Light, Gas and Water: No comments received. Office of Sustainability and Resilience: No comments received. Office of Comprehensive Planning: See pages 19-21. Staff Report February 12, 2026 SUP 2026-001 Page 17 17 City Engineer: 1. Standard Public Improvement Contract or Right -Of-Way Permit as required in Section 5.5.5 of the Unified Development Code. Sewers: 2. City sanitary sewer capacity is available to serve this development. Roads: 3. The Developer shall be responsible for the repair and/or replacement of all existing curb and gutter along the frontage of this site as necessary. 4. All existing sidewalks and curb openings along the frontage of this site shall be inspected for ADA compliance. The developer shall be responsible for any reconstruction or repair necessary to meet City standards. Traffic Control Provisions: 5. The developer shall provide a traffic control plan to the city engineer that shows the phasing for each street frontage during demolition and construction of curb gutter and sidewalk. Upon completion of sidewalk and curb and gutter improvements, a minimum 5 foot wide pedestrian pathway shall be provided throughout the remainder of the project. In the event that the existing right of way width does not allow for a 5 foot clear pedestrian path, an exception may be considered. 6. Any closure of the right of way shall be time limited to the active demolition and construction of sidewalks and curb and gutter. Continuous unwarranted closure of the right of way shall not be allowed for the duration of the project. The developer shall provide on the traffic control plan, the time needed per phase to complete that portion of the work. Time limits will begin on the day of closure and will be monitored by the Engineering construction inspectors on the job. 7. The developer’s engineer shall submit a Trip Generation Report that documents the proposed land use, scope and anticipated traffic demand associated with the proposed development. A detailed Traffic Impact Study will be required when the accepted Trip Generation Report indicates that the number for projected trips meets or exceeds the criteria listed in Section 210 -Traffic Impact Policy for Land Development of the City of Memphis Division of Engineering Design and Policy Review Manual. Any required Traffic Impact Study will need to be formally approved by the City of Memphis, Traffic Engineering Department. Curb Cuts/Access: 8. The City Engineer shall approve the design, number, and location of curb cuts. 9. Any existing nonconforming curb cuts shall be modified to meet current City Standards or closed with curb, gutter, and sidewalk. Staff Report February 12, 2026 SUP 2026-001 Page 18 18 City Fire Division: 1. All design and construction shall comply with the 2021 edition of the International Fire Code with local amendments and referenced standards. 2. Fire apparatus access shall comply with section 503. 3. Where security gates are installed that affect required fire apparatus access roads, they shall comply with section 503.6. 4. Fire protection water supplies (including fire hydrants) shall comply with section 507. 5. Where fire apparatus access roads or a water supply for fire protection are required to be installed, such protection shall be installed and made serviceable prior to and during the time of construction except when approved alternate methods of protection are provided. 6. IFC 510 In-building two-way emergency responder communication coverage shall be provided in all new and existing buildings. Buildings and structures that cannot support the required level of coverage shall be equipped with systems and components to enhance signals and achieve the required level of communication coverage. 7. A detailed plans review will be conducted by the Memphis Fire Prevention Bureau upon receipt of complete construction documents. Plans shall be submitted to the Shelby County Office of Code Enforcement. Staff Report February 12, 2026 SUP 2026-001 Page 19 19 Office of Comprehensive Planning This summary is being produced in response to the following application to support the Land Use and Development Services Department in their recommendation: SUP 2026-001 Oakhaven/Parkway Village Site Address/Location: 3575 Emerald St Overlay District/Historic District/Flood Zone: Site overlaps with a flood zone Future Land Use Designation: Low Intensity Commercial and Services (CSL) Street Type: Avenue The applicant is requesting a Special Use Permit to allow office/showroom for motor vehicle sales. The following information about the land use designation can be found on pages 76 – 122: 1. Future Land Use Planning Map Red polygon indicates the application site on the Future Land Use Map. 2. Land Use Description/Intent Low Intensity Commercial and Service (CSL) areas are typically not associated with anchors. These areas may include neighborhood supporting commercial uses such as retail sales and services, offices, restaurants, funeral services, small-scale recreation, social service institutions, and occasional upper-story residential. Graphic portrayal of CSL is to the right. Staff Report February 12, 2026 SUP 2026-001 Page 20 20 “CSL” Form & Location Characteristics Commercial and services uses, 1-4 stories height “CSL” Zoning Notes Generally compatible with the following zone districts: CMU-1 without frontage requirements, OG, SDBP in accordance with Form and characteristics listed above. Existing, Adjacent Land Use and Zoning Existing Land Use and Zoning: Commercial; CMU-1 Adjacent Land Use and Zoning: Commercial, Office, Institutional; CMU-1, R-6 Overall Compatibility: This requested use is compatible with the existing land use description/intent, form & location characteristics, zoning notes. It is consistent with the existing, adjacent land uses such as a gas station and an auto parts & car repair shop. Degree of Change Map Red polygon denotes the proposed site on the Degree of Change Map. There is no Degree of Change. 3. Degree of Change Description N/A 4. Objectives/Actions Consistent with Goal 1, Complete, Cohesive, Communities N/A 5. Pertinent Sections of Memphis 3.0 that Address Land Use Recommendations Staff Report February 12, 2026 SUP 2026-001 Page 21 21 Consistency Analysis Summary The applicant is requesting a Special Use Permit to allow office/showroom for motor vehicle sales. This requested use is not compatible with the existing land use description/intent, form & location characteristics, zoning notes. It is consistent with the existing, adjacent land uses such as a gas station and an auto parts & car repair shop. Based on the information provided, the proposal is CONSISTENT with the Memphis 3.0 Comprehensive Plan. Staff Report February 12, 2026 SUP 2026-001 Page 22 22 MAILED PUBLIC NOTICE Staff Report February 12, 2026 SUP 2026-001 Page 23 23 SIGN AFFIDAVIT Staff Report February 12, 2026 SUP 2026-001 Page 24 24 Staff Report February 12, 2026 SUP 2026-001 Page 25 25 NIEGHBORHOOD MEETING SUMMARY Staff Report February 12, 2026 SUP 2026-001 Page 26 26 Staff Report February 12, 2026 SUP 2026-001 Page 27 27 APPLICATION Staff Report February 12, 2026 SUP 2026-001 Page 28 28 Staff Report February 12, 2026 SUP 2026-001 Page 29 29 Staff Report February 12, 2026 SUP 2026-001 Page 30 30 Staff Report February 12, 2026 SUP 2026-001 Page 31 31 OWNER AFFIDAVIT Staff Report February 12, 2026 SUP 2026-001 Page 32 32 LETTER OF INTENT Staff Report February 12, 2026 SUP 2026-001 Page 33 33 Staff Report February 12, 2026 SUP 2026-001 Page 34 34 Staff Report February 12, 2026 SUP 2026-001 Page 35 35 LETTERS RECEIVED No letters received at the time of completion of this report. East Service Center: 6465 Mullins Station Rd; Memphis, Tennessee 38134 Downtown Service Center: 125 N. Main Street; Memphis, T ennessee 38103 website: www.develop901.com Memphis and Shelby County Division of Planning and Development Record Summary for Special Use Permit Record Detail Information Record T ype: Special Use Permit Record Status: Assignment Opened Date: January 2, 2026 Record Number: SUP 2026-001 Record Name: Small's Automotive, LLC Expiration Date: Description of Work: Special Use Permit to allow office/showroom for motor vehicle sales, service and repair of vehicles Parent Record Number: Address: 3575 EMERALD ST, MEMPHIS, Tennessee 381 15 Owner Information Primary Owner Name Owner Address Owner Phone Y L & A AUTOMOTIVE LLC 2635 FRIDDELL CV, MEMPHIS, TN 38133 9015305441 Parcel Information 074102 00092 Data Fields PREAPPLICA TION MEETING Name of DPD Planner Mahsan Ostadnia Date of Meeting 12/18/2025 Pre-application Meeting Type In Person GENERAL PROJECT INFORMATION Application Type New Special Use Permit (SUP) List any relevant former Docket / Case Number(s) related to previous applications on this site - Is this application in response to a citation, stop No Page 1 of 4 SUP 2026-001 GENERAL PROJECT INFORMATION work order, or zoning letter If yes, please provide a copy of the citation, stop work order, and/or zoning letter along with any other relevant information - APPROVAL CRITERIA A) The project will not have a substantial or undue adverse ef fect upon adjacent property, the character of the neighborhood, traffic conditions, parking, utility facilities and other matters affecting the public health, safety, and general welfare The adjacent land uses to the south for a small retail center and convenient store with gasoline pumps directly facing Winchester Road, including the auto repair shop directly adjacent to the north will not be affected by this proposal. Nor will the charter school directly across the street from the subject property and the existing auto wheel repair shop and cable contracting facility be affected by the proposed use. The property, including adjacent property to the north in single ownership is totally enclosed with a wrought-iron decorative fence for security and safety inside and outside the property. B) The project will be constructed, arranged and operated so as to be compatible with the immediate vicinity and not interfere with the development and use of adjacent property in accordance with the applicable district regulations The subject property, including site improvements will be utilized and maintained in its current conditions and no new construction is proposed in this application. The proposal will be arranged and operated in a manner to be compatible with surrounding properties and will not interfere with any future development and use of any adjacent property in accordance with the CMU-1 District regulations. UDC Sub-Section 9.6.9C The subject property is currently served by essential public facilities by a public street, adequate access, parking, circulation, refuse, fire and emergency services, including electricity, natural gas, water, adequate drainage, and sewer services are provided on the property. UDC Sub-Section 9.6.9D The subject property does not have any history of being or possessing any significant natural, scenic or historic importance that will result in the destruction, loss or damage of any feature(s) determined by any governing body. UDC Sub-Section 9.6.9E The proposed project, if approved will comply with the Use Standard provisions of Sub-Section 2.6.3.P of the UDC for motor vehicle sales, service and repair, including outdoor display and sales requirements of Sub-Section 4.8.4A as allowed by Special Use Permit. Page 2 of 4 SUP 2026-001 APPROVAL CRITERIA UDC Sub-Section 9.6.9F Memphis 3.0’s Low Intensity Commercial Services (often aligned with auto-oriented corridors or small-scale service commercial areas typically supports: • Small format retail and service use • Low impact commercial activity • Uses that do not generate heavy traffic, noise, or outdoor storage • Development that is compatible with adjacent residential or neighborhood scale commercial properties Motor vehicle sales can fit into commercial service areas by Special Use Permit (SUP). The intent is to activate an existing commercial property with a low-impact use that aligns with the corridor’s character and the Memphis 3.0 vision for reinvestment in established commercial areas. The proposed use fits within this context and does not introduce a new or incompatible development pattern. The scale of the operation is modest, and the applicant is committed to meeting the proposed Sit Plan Conditions. •Existing Context: The surrounding area already contains commercial and light industrial uses. Motor vehicle sales are consistent with the corridor’s established development pattern. • Low Intensity Operations: The applicant proposes a small format sales operation with limited inventory, no outdoor repair activity, and no high-volume traffic generation. GIS INFORMATION Case Layer - Central Business Improvement District No Class C Downtown Fire District No Historic District - Land Use COMMERCIAL Municipality MEMPHIS Overlay/Special Purpose District - Zoning CMU-1 State Route - Lot 6 & 7 Subdivision EMERALD SQUARE Planned Development District - Wellhead Protection Overlay District Yes County Commission District - Page 3 of 4 SUP 2026-001 GIS INFORMATION City Council District - City Council Super District - Contact Information BRIAN S. BACCHUS (901)785-5988 APPLICANT Name Address Phone Contact Type BRIAN BACCHUS (901)785-5988 REPRESENT ATIVE Name Address Phone Contact Type Fee Information Date AssessedBalanceStatusFeesQuantityFee ItemInvoice # 01/02/20260.00INVOICED500.001Special Use Permit Fee - 5 acres or less (Base Fee) 1699195 01/02/20260.00INVOICED13.001Credit Card Use Fee (.026 x fee) 1699195 Total Fee Invoiced : $513.00 Total Balance: $0.00 Payment Information Payment Amount Method of Payment Credit Card$513.00 Page 4 of 4 SUP 2026-001 BUD Group 'From the Property Line to the Parapet' LETTER OF INTENT BUD GROUP (Bacchus Urban Design Group) Brian S. Bacchus, Principal Consultant 5320 White Diamond Street Memphis, TN 38109 Date: December 31, 2025 To: Land Use Control Board Secretary, Chairman, Vice-Chairman and Board Members Re: 3575 Emerald Street Special Use Permit: Motor Vehicle Sales and Service Greetings Mr. Secretary, On behalf of the property owner, L & A Automotive, LLC and Mr. Dennis Small of S mall’s Automotive, LLC, we are requesting a Special Use Permit for the above-mentioned property to allow motor vehicle sales and service on two (2) lots in Emerald Square Subdivision totaling 0.50 acres or 22, 170 sq. ft. in area. The lots are in Commercial Mixed Use (CMU-1) District zoning at the west side of Emera ld Street , +/-160.62 feet north of Winche ster Road over one-quarter (¼) mile from Williamsburg Colony and Bishop ’s Bri dge neighborhoods in the southeast portion of the City of Memphis. The site was a former vehicle wash and automotive service facility permitted by right in the CMU-1 District. The applicant, Mr. Small is proposing the principal use of the property for motor vehicle sales and services as outlined in the proposed enclosed Site Plan Conditions and agreed upon by the applicant with limited retail sales of automotive products such as lubrication, motor oil and oil filters, auto wax, auto cloths, and auto cleaning products. The use of space within the main building will include reception desk, sales counter, sales offices, break rooms, bathrooms, storage areas and a mini-indoor showroom with outdoor auto display bays attached to the main building. The proposed land use for motor vehicle service is permitted by right in the CMU-1 District, but the request for motor vehicle sales is permitted by Special Use Permit. The motor vehicle sales will be located on the balance of the property with designated s ales and display area s for customer service for a total displa y of ve hicles for sale and display at any one time will be a maximum of twenty-five (25) vehicles. BUD Group 'From the Property Line to the Parapet' The required parking spaces for motor vehicle sales and service are a ratio of 1:500 sq. ft. of indoor floor area plus a ratio of 1:10,000 sq. ft. for outdoor lot area for a total of seven (7) required parking spaces, including one (1) handicap space. Parking will be provided for the main building and outdoor motor vehicle display area to meet required parking for all proposed indoor and outdoor uses of the property as illustrated on the site plan. This facility is intended to serve the southeastern portion of the City of Memphis, focusing on residential neighborhoods such as Williamsburg Colony and Bishop’s Bridge, as well as the surrounding commercial establishments, including the Mendenhall Square Retail Shopping Center. The market comprises individuals and families seeking reliable pre-owned vehicles and automotive services, along with local businesses in need of fleet maintenance and vehicle care. By offering both sales and service, the site aims to meet the diverse tran sportation needs of a sustainable market area. The applicant, Small’s Automotive, LLC prides itself in being the Number #1 source for buying quality pre -owned vehicles in the marketplace with extensive relationships in the dealer’s community, which allows them to purchase a wide variety of lease returns and new car trades at exceptional values. This model enables them to pass along huge savings on the highest quality vehicles of choice in this service market. In summary, the request for approval of a Special Use Permit with conditions to allow motor vehicle sales and service at this location is articulated as follows: motor vehicle sales display area for up to twenty-five (25) vehicles which will meet required parking standards with seven (7) spaces, including one (1) space. The application also details compliance with zoning and proposed site plan conditions. On behalf of the applicant , we respectfully request a favorable recommendation for a Special Use Permit to allow the propos ed land use within this market area in the s outheastern portion of the City of Memphis. Sincerely, Brian S. Bacchus, Principal Consultant BUD Group (901) 832-7203 BacchusUrbanDesignGroup@Outlook.com cc: Mr. Dennis Small, Small’s Automotive, LLC Chairman, Vice Chairman and Board Members BUD Group ‘From the Property Line to the Parapet’ S.U.P. 2026-??? 3575 Emerald Street Site Plan Conditions (Proposed) D/B/A: Small’s Automotive, LLC 1. The special permit to allow office/showroom for motor vehicle sales, service and repair of vehicles, including twenty-four (24) hour roadside assistance and short- term vehicle storage. 2. The applicable Use Standard provisions of Sub-Section 2.6.3P of the UDC for motor vehicle sales, service, and repair shall be applied to the subject property. 3. The outdoor display and sales shall be limited to the requirements of UDC Sub - Section 4.8.4A, but to include outdoor sales, display, limited general outdoor storage of motor vehicles and merchandise. 4. The existing wrought -iron fencing shall be preserved and maintained. Any new fencing and gating shall m atch existing fence material. No razor wire or barbed wire shall be permitted. 5. All required parking and vehicle display areas shall maintain the surface parking and all parking spaces shall be delineated with striped painted lines. 6. Detached and attached signs shall be as permitted and regulated in the Commercial Mixed Use (CMU-1) District. S.U.P. 2026-??? Site Plan Conditions Shelby County ITS / ReGIS 160 North Main, Suite 1000, Memphis, TN 38103 email: ReGIS@shelbycountytn.gov | www.gis.shelbycountytn.gov , ReGIS Shelby County Government Willie F . Brooks, Jr. Shelby County Register of Deeds Parcel ID: Owner Address: Parcel Address: Owner: 074102 00092 3575 EMERALD ST L & A AUTOMOTIVE LLC 2635 FRIDDELL CV Map prepared on 12/30/2025 2025 Appraisal: $194,600 T ax District: MEMPHIS Year Built: Lot Number: 6 &amp; 7 Subdivision: EMERALD SQUARE Plat BK & PG: UNKNOWN Dimensions: T otal Acres: 0.509 MEMPHIS TN 38133 5157 0 60 120 ft¯ Legend polygonLayer Override 1 Override 2 polylineLayer Override 1 Roads Parcels 0 0.03 0.06 0.09 0.12 mi Map prepared through Shelby County Government's online mapping Portal on 12/30/2025 ¯ 074102 00085C - MEMPHIS CATV 074102 00093 - CABLE HOLDCO II INC 074102 00092 - L & A AUTOMOTIVE LLC 093418 A00008 - SMITH JOANN 093418 A00009 - PAYNE JOHN L AND TRINA M PAYNE 093418 A00010 - PAYNE JOHN L AND TRINA M PAYNE 093418 A00011 - PAYNE JOHN L AND TRINA M PAYNE 093418 A00043 - GARCIA YANETH G 093418 A00014 - JECK FOUNDATION COMPANY 074102 A00049 - HARRIS TIMOTHY E 074102 00097 - CATHOLIC DIOCESE OF MEMPHIS 074102 00084 - DOZIER CARROLL T REV BISHOP 074102 00101 - GESTALT COMMUNITY SCHOOLS 074102 00091 - GIPSON LOVELACE P AND AMANDA T GIPSON 074102 00090 - AIC ENTERPRISES INC 074102 00089 - WAHAB SALAM 093418 A00001 - INDUSTRY DEVELOPMENT & CONSULTANTS LLC 093418 A00002 - INDUSTRY DEVELOPMENT & CONSULTANTS LLC 093418 A00003 - MALONE FAMILY LIVING TRUST FAMILY 093418 A00004 - HARMON OLIVER (ESTATE OF) AND JANICE H 093418 A00005C - COLEMAN CLARENCE W JR 093418 A00007 - SMITH JOANN 093418 A00012 - PAYNE JOHN L AND TRINA M PAYNE 093418 A00044 - GARCIA YANETH G 093418 A00013 - JECK FOUNDATION COMPANY 093418 A00042 - GARCIA YANETH G 093418 A00041 - GARCIA YANETH G 093418 A00040 - STARNES JIMMY W & GAIL O 074102 00087C - L AND A AUTOMOTIVE LLC 093400 A00016 - PCAMS HOLDINGS 093400 00598 - SANDLIAN LANCE B 093418 A00045 - WINCHESTER OFFICE PLAZA CONDOMINIUMS 093400 A00002 - PCAMS HOLDINGS 093400 A00001 - GESTALT COMMUNITY SCHOOLS 093400 A00015 - GESTALT COMMUNITY SCHOOLS BUD GROUP (Bacchus Urban Design Group) Brian S. Bacchus, Principal Consultant 5320 White Diamond Street Memphis, TN 38109 BacchusUrbanDesignGroup@Outlook.com 3575 Emerald Street BUD Group ‘From the Property Line to the Parapet’ Memphis 3.0 Consistency Statement 3575 Emerald Street — Motor Vehicle Sales (SUP Request) The proposed motor vehicle sales use is consistent with the Memphis 3.0 Comprehensive Plan as it applies to the Low Intensity Commercial Services place type. This place type supports neighborhood -scale commercial activity, small service businesses, and auto-oriented commercial uses when designed to minimize off -site impacts. The proposal maintains the intended character by: • Reusing an existing commercial site without increasing intensity beyond what the corridor already supports • Limiting operations to low-impact vehicle sales with no repair, body work, or outdoor storage of inoperable vehicles • Providing site improvements such as landscaping, screening, and controlled access that enhance the corridor’s appearance • Maintaining compatibility with adjacent commercial and industrial properties while buffering nearby residential uses Memphis 3.0 emphasizes reinvestment in existing commercial corridors and supports adaptive reuse of underutilized sites. This proposal aligns with those goals by activating a vacant or underperforming parcel with a use that can be conditioned to remain low-intensity and neighborhood-compatible. BUD GROUP (Bacchus Urban Design Group) Brian S. Bacchus, Principal Consultant 5320 White Diamond Street Memphis, TN 38109 BacchusUrbanDesignGroup@Outlook.com 3575 Emerald Street BUD Group ‘From the Property Line to the Parapet’ Compatibility Argument Impact on Adjacent Properties & Neighborhood Character The proposed use will not adversely affect adjacent properties or the character of the immediate area for the following reasons: • Existing Context: The surrounding area already contains commercial and light-industrial uses. Motor vehicle sales is consistent with the corridor’s established development pattern. • Low-Intensity Operations: The applicant proposes a small -format sales operation with limited inventory, no outdoor repair activity, and no high -volume traffic generation. • Site Design Enhancements: Landscaping, fencing, and controlled access points will improve the site’s appearance and reduce visibility of vehicles from the public right-of-way. • Traffic & Safety: The use does not introduce heavy truck traffic or high -turnover vehicle movements. Access points remain unchanged or improved to meet UDC standards. • Noise & Lighting: Operations occur during normal business hours, with lighting designed to avoid spillover onto adjacent properties. With these conditions, the use is compatible with nearby development and does not create negative externalities. BUD GROUP (Bacchus Urban Design Group) Brian S. Bacchus, Principal Consultant 5320 White Diamond Street Memphis, TN 38109 BacchusUrbanDesignGroup@Outlook.com 3575 Emerald Street BUD Group ‘From the Property Line to the Parapet’ Staff-Friendly Narrative Purpose & Intent The applicant seeks approval of a Special Use Permit to allow a small -scale motor vehicle sales establishment at 3575 Emerald Street. The intent is to activate an existing commercial property with a low -impact use that aligns with the corridor’s character and the Memphis 3.0 vision for reinvestment in established commercial areas. Consistency With Surrounding Developments The site is located within a corridor characterized by commercial services, auto -oriented uses, and light industrial activity. The proposed use fits within this context and does not introduce a new or incompatible development pattern. The scale of the operation is modest, and the applicant is committed to meeting all UDC requirements for landscaping, buffering, and site design. Public Interest & Neighborhood Benefit The project improves an underutilized site, enhances the streetscape through required landscaping, and provides controlled, well -maintained commercial use. No adverse impacts on traffic, noise, or adjacent residential areas are anticipated. The proposal supports economic activity while maintaining the low-intensity character envisioned for this area. CITY OF MEMPHIS COUNCIL AGENDA CHECK OFF SHEET ___________________________________________________________________________________ | ONE ORIGINAL | Planning & Development | ONLY STAPLED | DIVISION |TO DOCUMENTS| Planning & Zoning COMMITTEE: 0 3/24/2026 DATE PUBLIC SESSION: 04/ 14/2026 DATE ITEM (CHECK ONE) ORDINANCE X RESOLUTION REQUEST FOR PUBLIC HEARING = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = ITEM DESCRIPTION: Resolution pursuant to Chapter 9.6 of the Memphis and Shelby County Unified Development Code approving a special use permit at the subject property located at 4180 Elliston Road, known as case number SUP 2026- 005 CASE NUMBER: SUP 2026-005 LOCATION: 4180 Elliston Road COUNCIL DISTRICTS: District 4 and Super District 9 – Positions 1, 2, and 3 OWNER/APPLICANT: Leadership Preparatory, Inc. REPRESENTATIVE: Doug Baker REQUEST: To allow a childcare center AREA: +/- 40,423 square feet RECOMMENDATION: The Division of Planning and Development recommended Approval with conditions The Land Use Control Board recommended Approval with conditions RECOMMENDED COUNCIL ACTION: Public Hearing Not Required Hearing – April 14, 2026 = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = PRIOR ACTION ON ITEM: (1) APPROVAL - (1) APPROVED (2) DENIED 03/12/2026 DATE (1) Land Use Control Board ORGANIZATION - (1) BOARD / COMMISSION (2) GOV’T. ENTITY (3) COUNCIL COMMITTEE = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = FUNDING: (2) REQUIRES CITY EXPENDITURE - (1) YES (2) NO $ AMOUNT OF EXPENDITURE $ REVENUE TO BE RECEIVED SOURCE AND AMOUNT OF FUNDS $ OPERATING BUDGET $ CIP PROJECT #_______________________________ $ FEDERAL/STATE/OTHER = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = ADMINISTRATIVE APPROVAL: DATE POSITION _____________________________________________ ____________ PLANNER II _____________________________________________ ____________ DEPUTY ADMINISTRATOR _____________________________________________ ____________ ADMINISTRATOR _____________________________________________ ____________ DIRECTOR (JOINT APPROVAL) _____________________________________________ ____________ COMPTROLLER _____________________________________________ ____________ FINANCE DIRECTOR _____________________________________________ ____________ CITY ATTORNEY = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = _____________________________________________ ____________ CHIEF ADMINISTRATIVE OFFICER _____________________________________________ ____________ COMMITTEE CHAIRMAN 3/16/2026 3/16/2026 3/16/2026 Memphis City Council Summary Sheet SUP 2026-005 RESOLUTION PURSUANT TO CHAPTER 9.6 OF THE MEMPHIS AND SHELBY COUNTY UNIFIED DEVELOPMENT CODE APPROVING A SPECIAL USE PERMIT AT THE SUBJECT PROPERTY LOCATED AT 4180 ELLISTON ROAD, KNOWN AS CASE NUMBER SUP 2026-005 • This item is a r esolution with conditions for a special use permit to allow a childcare center; and • The item may require future public improvement contracts. 1 LAND USE CONTROL BOARD RECOMMENDATION At its regular meeting on Thursday, March 12, 2026, the Memphis and Shelby County Land Use Control Board held a public hearing on the following application: CASE NUMBER: SUP 2026-005 LOCATION: 4180 Elliston Road COUNCIL DISTRICT(S): District 4 and Super District 9 – Positions 1, 2, and 3 OWNER/APPLICANT: Leadership Preparatory, Inc. REPRESENTATIVE: Doug Baker REQUEST: To allow a childcare center EXISTING ZONING: Residential Single-Family – 6 (R-6) AREA: +/- 40,423 square feet The following spoke in support: None The following spoke in opposition: None The Land Use Control Board reviewed the application and the staff report. A motion was made and seconded to recommend approval with conditions. The motion passed by a vote of 8-0 on the consent agenda. Respectfully, Chloe Christion Planner II Land Use and Development Services Division of Planning and Development Cc: Committee Members File 2 SUP 2026-005 CONDITIONS 1. The exact location of the crosswalk shall be determined and approved by the City Engineer via the Administrative Site Plan Review (ASPR) process. 2. A Class III Buffer shall be provided along the western property line. An alternative buffer may be approved through the site plan review process by the Division of Planning and Development. 3. A final site/landscape plan shall be submitted subject to the review and approval of the Division of Planning and Development. 3 SITE PLAN RESOLUTION PURSUANT TO CHAPTER 9.6 OF THE MEMPHIS AND SHELBY COUNTY UNIFIED DEVELOPMENT CODE APPROVING A SPECIAL USE PERMIT AT THE SUBJECT PROPERTY LOCATED AT 4180 ELLISTON ROAD , KNOWN AS CASE NUMBER SUP 2026- 005 WHEREAS, Chapter 9.6 of the Memphis and Shelby County Unified Development Code, being a section of the Joint Ordinance Resolution No. 5367, dated August 10, 2010, authorizes the Council of the City of Memphis to grant a special use permit for certain stated purposes in the various zoning districts; and WHEREAS, Leadership Preparatory, Inc. filed an application with the Memphis and Shelby County Division of Planning and Development to allow a childcare center; and WHEREAS, the Division of Planning and Development has received and reviewed the application in accordance with procedures, objectives, and standards for special use permits as set forth in Chapter 9.6 with regard to the proposed development's impacts upon surrounding properties, availability of public facilities, both external and internal circulation, land use compatibility, and that the design and amenities are consistent with the public interest; and has submitted its findings and recommendation concerning the above considerations to the Land Use Control Board; and WHEREAS, a public hearing in relation thereto was held before the Memphis and Shelby County Land Use Control Board on March 12, 2026, a nd said Board has submitted its findings and recommendation concerning the above considerations to the Council of the City of Memphis; and WHEREAS, the Council of the City of Memphis has reviewed the aforementioned application pursuant to Tennessee Code Annotated Section 13-4- 202(B)(2)(B)(iii) and has determined that said development is consistent with the Memphis 3.0 General Plan; and WHEREAS, the Council of the City of Memphis has reviewed the recommendation of the Land Use Control Board and the report and recommendation of the Division of Planning and Development and has determined that said development meets the objectives, standards and criteria for a special use permit, and said development is consistent with the public interests. NOW, THEREFORE, BE IT RESOLVED, BY THE COUNCIL OF THE CITY OF MEMPHIS, that, pursuant to Chapter 9.6 of the Memphis and Shelby County Unified Development Code, a special use permit is hereby granted for the request use in accordance with the attached conditions. BE IT FURTHER RESOLVED , that this permit merely authorizes the filing of applications to acquire a Certificate of Use and Occupancy, or a Building Permit, and other required permits and approvals, provided that no such Certificate of Use and Occupancy shall be granted until all conditions imposed by the Council of the City of Memphis have been met. BE IT FURTHER RESOLVED , that this Resolution take effect from and after the date it shall have been passed by this Council of the City of Memphis, and become effective as otherwise provided by law, and thereafter shall be treated as in full force and effect by virtue of passage thereof by the Council of the City of Memphis, the public welfare requiring same. CONDITIONS 1. The exact location of the crosswalk shall be determined and approved by the City Engineer via the Administrative Site Plan Review (ASPR) process. 2. A Class III Buffer shall be provided along the western property line. An alternative buffer may be approved through the site plan review process by the Division of Planning and Development. 3. A final site/landscape plan shall be submitted subject to the review and approval of the Division of Planning and Development. SITE PLAN ATTEST: CC: Division of Planning and Development – Land Use and Development Services – Office of Construction Enforcement Staff Writer: Chloe Christion E-mail: chloe.christion@memphistn.gov AGENDA ITEM: 12 L.U.C.B. MEETING: March 12, 2026 CASE NUMBER: SUP 2026-0005 LOCATION: 4180 Elliston Road COUNCIL DISTRICT: District 4 and Super District 9 – Positions 1, 2, and 3 OWNER/APPLICANT: Leadership Preparatory, Inc. REPRESENTATIVE: Doug Baker REQUEST: Special use permit to allow a childcare center EXISTING ZONING: Residential Single-Family – 6 (R-6) CONCLUSIONS 1. The applicant is proposing to construct a day care facility for Leadership Prep Charter School. The facility would accommodate up to twenty-three children ages 6 months to 4 years old. Operating hours would be from 6:30AM to 2:00 PM in order to minimize conflicts with the schools operating times of 8:00 AM to 3:30 PM. 2. Upon the request of staff, the applicant has submitted a revised site plan with a crosswalk across Elliston Road. Note that the exact location of the crosswalk would be determined by the City Engineer prior to the approval of any building permits. 3. The proposed site plan provides a 10’ Class II Type A landscape buffer along the western property line, however per UDC 2.6.2B(1)(b), a Class III buffer is required. The applicant has the option to provide a 7’ or 10’ Class III buffer along the western property line. 4. The granting of this special use permit will not cause substantial detriment to the public good, nor will it substantially impair the intent and purpose of an adopted plan or the Unified Development Code (UDC), nor will it be injurious to the neighborhood or the general welfare, and it will be in harmony with the purpose and intent of the UDC. CONSISTENCY WITH MEMPHIS 3.0 This proposal is not applicable with the Memphis 3.0 General Plan per the land use decision criteria. RECOMMENDATION: Approval with conditions Staff Report March 12, 2026 SUP 2026-0005 Page 2 2 LOCATION MAP Subject property located within the pink circle SUBJECT PROPERTY Staff Report March 12, 2026 SUP 2026-0005 Page 3 3 PUBLIC NOTICE VICINITY MAP Subject property outlined in red PUBLIC NOTICE DETAILS In accordance with Sub-Section 9.3.4A of the Unified Development Code, a notice of public hearing is required to be mailed and signage posted. A total of 170 notices were mailed on February 20, 2026 , see page 19 of this report for a copy of said notice . Additionally, one sign was posted at the subject property, see page 20 of this report for a copy of the sign affidavit. NEIGHBORHOOD MEETING The meeting was held at 6:00 PM on February 26, 2026, at 4190 Elliston Road. Staff Report March 12, 2026 SUP 2026-0005 Page 4 4 E L ROGERS EAST MEMPHIS PARK SUBDIVISION (1933) (PLAT BOOK 9 PAGE 103) Subject property highlighted in yellow, part of Lot 19 Staff Report March 12, 2026 SUP 2026-0005 Page 5 5 AERIAL Subject property outlined in yellow, imagery from 2025 Staff Report March 12, 2026 SUP 2026-0005 Page 6 6 ZONING MAP Subject property highlighted in yellow Staff Report March 12, 2026 SUP 2026-0005 Page 7 7 LAND USE MAP Subject property indicated by a pink star Staff Report March 12, 2026 SUP 2026-0005 Page 8 8 SITE PHOTOS View of existing residence to be demolished on subject property from Elliston Road facing north. View of Leadership Prep Charter School from Elliston Road facing north. Staff Report March 12, 2026 SUP 2026-0005 Page 9 9 View of Leadership Prep Charter School parking lot. Staff Report March 12, 2026 SUP 2026-0005 Page 10 10 SITE PLAN Staff Report March 12, 2026 SUP 2026-0005 Page 11 11 SITE PLAN – MAGNIFIED Staff Report March 12, 2026 SUP 2026-0005 Page 12 12 CASE REVIEW Request The request is a special use permit to allow a childcare center. Approval Criteria Staff agrees t he approval criteria in regard to special use permits as set out in Section 9. 6.9 of the Unified Development Code are met. 9.6.9 Approval Criteria No special use permit or planned development shall be approved unless the following findings are made concerning the application: 9.6.9A The project will not have a substantial or undue adverse effect upon adjacent property, the character of the neighborhood, traffic conditions, parking, utility facilities and other matters affecting the public health, safety, and general welfare. 9.6.9B The project will be constructed, arranged and operated so as to be compatible with the immediate vicinity and not interfere with the development and use of adjacent property in accordance with the applicable district regulations. 9.6.9C The project will be served adequately by essential public facilities and services such as streets, parking, drainage, refuse disposal, fire protection and emergency services, water and sewers; or that the applicant will provide adequately for such services. 9.6.9D The project will not result in the destruction, loss or damage of any feature determined by the governing bodies to be of significant natural, scenic or historic importance. 9.6.9E The project complies with all additional standards imposed on it by any particular provisions authorizing such use. 9.6.9F The request will not adversely affect any plans to be considered (see Chapter 1.9), or violate the character of existing standards for development of the adjacent properties. 9.6.9G The governing bodies may impose conditions to minimize adverse effects on the neighborhood or on public facilities, and to ensure compatibility of the proposed development with surrounding properties, uses, and the purpose and intent of this development code. 9.6.9H Any decision to deny a special use permit request to place, construct, or modify personal wireless service facilities shall be in writing and supported by substantial evidence contained in a written record, per the Telecommunications Act of 1996, 47 USC 332(c)(7)(B)(iii). The review body may not take into account any environmental or health concerns. Site Details Address: 4180 Elliston Road Parcel ID: 058161 00030 and 058161 00026C Area: +/- 40,423 square feet Description: Staff Report March 12, 2026 SUP 2026-0005 Page 13 13 The subject property is a part of lot 19 of the EL Rogers East Memphis Park Subdivision recorded in plat book 9, page 103. The property is zoned Residential Single -Family – 6 (R-6). Per the Assessor’s website, the principal structure on the property is a single-family residence built in 1942 with a ground floor area of 920 square feet. The principal structure to the east is a charter school. There is one street frontage on the subject property along Elliston Road, and a surface parking lot. Note there is a sha red parking agreement between the school and Elliston Church on Elliston Road directly south of the subject property. Relevant Unified Development Code Clauses Paragraph 2.6.2C(4) Public and private schools shall be required to obtain a special use permit prior to 1) installing or constructing a principal or accessory use or structure on a platted residential lot that does not abut a connector or arterial, or 2) using a platted residential lot that does not abut a connector or arterial for any principal or accessory use. Site Plan Review • Existing residential unit to be demolished • 1,895 s.f. proposed daycare facility • 10’ Class II Type A Landscaping buffer along western property line with 6’ sight-proof fence • Required streetscape trees along Elliston Road are insufficient. Four additional street trees along Elliston Road are required. • Shared parking agreement with Leadership Prep and Elliston Church • Proposed crosswalk across Elliston Road • Playground area to the rear of the structure Analysis The applicant is proposing to construct a day care facility for Leadership Prep Charter School. The facility would accommodate up to twenty-three children ages 6 months to 4 years old. Operating hours would be from 6:30AM to 2:00 PM in order to minimize conflicts with the schools operating times of 8:00 AM to 3:30 PM. Upon the request of staff, the applicant has submitted a revised site plan with a crosswalk across Elliston Road. Note that the exact location of the crosswalk would be determined by the City Engineer prior to the approval of any building permits. The proposed site plan provides a 10’ Class II Type A landscape buffer along the western property line, however per UDC 2.6.2B(1)(b), a Class III buffer is required. The applicant has the option to provide a 7’ or 10’ Class III buffer along the western property line. The granting of this special use permit will not cause substantial detriment to the public good, nor will it substantially impair the intent and purpose of an adopted plan or the Unified Development Code (UDC), nor will it be injurious to the neighborhood or the general welfare, and it will be in harmony with the purpose and intent of the UDC. Staff Report March 12, 2026 SUP 2026-0005 Page 14 14 RECOMMENDATION Staff recommends approval with conditions. Conditions 1. The exact location of the crosswalk shall be determined and approved by the City Engineer via the Administrative Site Plan Review (ASPR) process. 2. A Class III Buffer shall be provided along the western property line. An alternative buffer may be approved through the site plan review process by the Division of Planning and Development. 3. A final site/landscape plan shall be submitted subject to the review and approval of the Division of Planning and Development. Staff Report March 12, 2026 SUP 2026-0005 Page 15 15 DEPARTMENTAL COMMENTS The following comments were provided by agencies to which this application was referred: City Engineer: See pages 17-18. County Engineer: No comments received. City Fire Division: 1. All design and construction shall comply with the 2021 edition of the International Fire Code with local amendments and referenced standards. 2. Fire apparatus access shall comply with section 503. 3. Where security gates are installed that affect required fire apparatus access roads, they shall comply with section 503.6. 4. Fire protection water supplies (including fire hydrants) shall comply with section 507. 5. Where fire apparatus access roads or a water supply for fire protection are required to be installed, such protection shall be installed and made serviceable prior to and during the time of construction except when approved alternate methods of protection are provided. 6. IFC 510 In-building two-way emergency responder communication coverage shall be provided in all new and existing buildings. Buildings and structures that cannot support the required level of coverage shall be equipped with systems and components to enhance signals and achieve the required level of communication coverage. 7. A detailed plans review will be conducted by the Memphis Fire Prevention Bureau upon receipt of complete construction documents. Plans shall be submitted to the Shelby County Office of Code Enforcement. County Fire Division: No comments received. City Real Estate: No comments received. County Health Department: No comments received. Shelby County Schools: No comments received. Construction Code Enforcement: No comments received. Memphis Light, Gas and Water: No comments received. Office of Sustainability and Resilience: No comments received. Staff Report March 12, 2026 SUP 2026-0005 Page 16 16 Office of Comprehensive Planning: No comments received. Staff Report March 12, 2026 SUP 2026-0005 Page 17 17 ENGINEERING COMMENTS CASE 10: SUP-26-005; Childcare center in R-6 District NAME: 4180 Elliston Rd; 05816100030 Basin/Lot/CD: Cherry Bayou, 6-A/.229ac/ 4 1. Standard Public Improvement Contract or Right-Of-Way Permit as required in Section 5.5.5 of the Unified Development Code. Sewers: 2. City sanitary sewers are available to serve this development. 3. A sanitary sewer service connection plan is required to be submitted (via 901 portal) to the City Land Development Office for review and approval. 4. All required design plans and potential traffic control plan must be prepared in accordance with the City’s Standard Requirements and must be stamped by a Professional Engineer registered in the State of Tennessee. 5. A Sewer Development fee may be required per the City of Memphis Sewer Use Ordinance. Roads: 6. The Developer shall be responsible for the repair and/or replacement of all existing curb and gutter along the frontage of this site as necessary. 7. All existing sidewalks and curb openings along the frontage of this site shall be inspected for ADA compliance. The developer shall be responsible for any reconstruction or repair necessary to meet City standards. Traffic Control Provisions: 8. The developer shall provide a traffic control plan to the city engineer that shows the phasing for each street frontage during demolition and construction of curb gutter and sidewalk. Upon completion of sidewalk and curb and gutter improvements, a minimum 5 foot wide pedestrian pathway shall be provided throughout the remainder of the project. In the event that the existing right of way width does not allow for a 5 foot clear pedestrian path, an exception may be considered. 9. Any closure of the right of way shall be time limited to the active demolition and construction of sidewalks and curb and gutter. Continuous unwarranted closure of the right of way shall not be allowed for the duration of the project. The developer shall provide on the traffic control plan, the time needed per phase to complete that portion of the work. Time limits will begin on the day of closure and will be monitored by the Engineering construction inspectors on the job. 10. The developer’s engineer shall submit a Trip Generation Report that documents the proposed land use, scope and anticipated traffic demand associated with the proposed development. A detailed Traffic Impact Study will be required when the accepted Trip Generation Report indicates that the number for projected Staff Report March 12, 2026 SUP 2026-0005 Page 18 18 trips meets or exceeds the criteria listed in Section 210-Traffic Impact Policy for Land Development of the City of Memphis Division of Engineering Design and Policy Review Manual. Any required Traffic Impact Study will need to be formally approved by the City of Memphis, Traffic Engineering Department. Curb Cuts/Access: 11. The City Engineer shall approve the design, number, and location of curb cuts. 12. Any existing nonconforming curb cuts shall be modified to meet current City Standards or closed with curb, gutter, and sidewalk. Drainage: 13. A grading and drainage plan for the site shall be submitted to the City Engineer for review and approval prior to recording of the final plat. 14. Drainage improvements, including possible on-site detention, shall be provided under a Standard Subdivision contract in accordance with Unified Development Code and the City of Memphis/Shelby County Storm Water Management Manual. 15. Drainage data for assessment of on-site detention requirements shall be submitted to the City Engineer. 16. The following note shall be placed on the final plat of any development requiring on-site storm water detention facilities: The areas denoted by "Reserved for Storm Water Detention" shall not be used as a building site or filled without first obtaining written permission from the City and/or County Engineer. The storm water detention systems located in these areas, except for those parts located in a public drainage easement, shall be owned and maintained by the property owner and/or property owners' association. Such maintenance shall be performed so as to ensure that the system operates in accordance with the approved plan on file in the City and/or County Engineer's Office. Such maintenance shall include, but not be limited to removal of sedimentation, fallen objects, debris and trash, mowing, outlet cleaning, and repair of drainage structures. 17. The developer should be aware of his obligation under 40 CFR 122.26(b)(14) and TCA 69-3-101 et. seq. to submit a Notice of Intent (NOI) to the Tennessee Division of Water Pollution Control to address the discharge of storm water associated with the clearing and grading activity on this site. 18. Development is located within a sensitive drainage basin and requires detention, drainage and grading engineering review. Staff Report March 12, 2026 SUP 2026-0005 Page 19 19 MAILED PUBLIC NOTICE Staff Report March 12, 2026 SUP 2026-0005 Page 20 20 SIGN AFFIDAVIT Staff Report March 12, 2026 SUP 2026-0005 Page 21 21 APPLICATION Staff Report March 12, 2026 SUP 2026-0005 Page 22 22 Staff Report March 12, 2026 SUP 2026-0005 Page 23 23 Staff Report March 12, 2026 SUP 2026-0005 Page 24 24 Staff Report March 12, 2026 SUP 2026-0005 Page 25 25 Staff Report March 12, 2026 SUP 2026-0005 Page 26 26 Staff Report March 12, 2026 SUP 2026-0005 Page 27 27 Staff Report March 12, 2026 SUP 2026-0005 Page 28 28 Staff Report March 12, 2026 SUP 2026-0005 Page 29 29 OWNER AFFIDAVIT Staff Report March 12, 2026 SUP 2026-0005 Page 30 30 LETTER OF INTENT Staff Report March 12, 2026 SUP 2026-0005 Page 31 31 Staff Report March 12, 2026 SUP 2026-0005 Page 32 32 Staff Report March 12, 2026 SUP 2026-0005 Page 33 33 Staff Report March 12, 2026 SUP 2026-0005 Page 34 34 Staff Report March 12, 2026 SUP 2026-0005 Page 35 35 Staff Report March 12, 2026 SUP 2026-0005 Page 36 36 LETTERS RECEIVED One letter of opposition was received at the time of completion of this report and ha s subsequently been attached. Outlook SUP 2026-005 From Glenn Little <oldsouthproperties@gmail.com> Date Mon 3/2/2026 12:16 PM To Christion, Chloe <Chloe.Christion@memphistn.gov> CAUTION: This email originated outside of the City of Memphis organization. Do not click links or open attachments unless you recognize the sender and know the content is safe. To Whom It May Concern, I am writing to formally express my concerns regarding the proposed childcare charter school development near residential properties that I own. While I support education and childcare services, I believe the proposed location raises significant concerns related to traffic congestion, parking limitations, noise levels, and long-term impacts on nearby residents and property values. The surrounding area consists primarily of residential housing, and the increased daily traffic and activity associated with a school may create ongoing disruptions for tenants. I respectfully request that alternative locations be considered or that additional studies and mitigation plans be required before approval is granted. Thank you for allowing public input on this matter. I appreciate your consideration of the concerns raised by local property owners and residents. -- Thanks,  Glenn Little O: 901-795-8000  3/2/26, 12:22 PM Mail - Christion, Chloe - Outlook https://outlook.office365.com/mail/inbox/id/AAQkADM3YmYxNzI4LWY1NjUtNDlmNy1hYWE1LTZjNjAzMWRkYzBmOQAQAHX0Xkyuhn1DnrD7ryZWgt… 1/1 East Service Center: 6465 Mullins Station Rd; Memphis, Tennessee 38134 Downtown Service Center: 125 N. Main Street; Memphis, T ennessee 38103 website: www.develop901.com Memphis and Shelby County Division of Planning and Development Record Summary for Special Use Permit Record Detail Information Record T ype: Special Use Permit Record Status: Pending Opened Date: January 30, 2026 Record Number: SUP 2026-005 Record Name: Leadership Prep Charter School Daycare Facility Expiration Date: Description of Work: Leadership Preparatory Charter School respectfully submits this application for a Special Use Permit to establish the Leadership Prep Daycare at 4180 Elliston Road, Memphis, Tennessee 38111. This proposed early childhood education facility will serve as a complementary extension to the existing Leadership Preparatory Charter School campus, which currently operates an elementary and middle school at adjacent properties on Elliston Road. The daycare facility is designed to serve up to twenty-three children ranging from 6 months to 4 years of age, with a staff of seven professionals. The facility will feature three specialized classrooms: an infant room, a toddler room, and a pre-kindergarten room that will provide early educational instruction to prepare children for their academic journey. Operating hours will be from 6:30 AM to 2:00 PM, strategically scheduled to minimize traffic conflicts with the adjacent school’s operating schedule of 8:00 AM to 3:30 PM. While the daycare will prioritize enrollment of children whose parents are employed at the adjacent Leadership Preparatory schools, it will be open to serve the broader community. This approach aligns with the school’s mission of supporting families and contributing to the educational infrastructure of the neighborhood. The subject property is in an R-6 zoning district with a Future Land Use designation of Anchor Neighborhood; Primarily Single-Unit. The property is strategically positioned within an established educational corridor, with the Leadership Preparatory Elementary School immediately to the east, Elliston Baptist Church, and Academy to the south, and single-family residences to the west and north. This context creates a natural educational cluster that enhances the compatibility of the proposed daycare use. The proposed Leadership Prep Daycare fully complies with all R-6 zoning district requirements for non-residential uses. Parent Record Number: Address: 4180 ELLISTON RD, MEMPHIS 381 11 Page 1 of 8 SUP 2026-005 Owner Information Primary Owner Name Owner Address Owner Phone Y LEADERSHIP PREP ARATORY INC 4190 ELLISTON RD, MEMPHIS, TN 38111 Parcel Information 058161 00030 Data Fields PREAPPLICATION MEETING Name of DPD Planner Chloe Christion Date of Meeting 12/04/2025 Pre-application Meeting Type Virtual GENERAL PROJECT INFORMATION Application Type New Special Use Permit (SUP) List any relevant former Docket / Case Number(s) related to previous applications on this site n/a Is this application in response to a citation, stop work order, or zoning letter No If yes, please provide a copy of the citation, stop work order, and/or zoning letter along with any other relevant information - APPROVAL CRITERIA Page 2 of 8 SUP 2026-005 APPROVAL CRITERIA A) The project will not have a substantial or undue adverse effect upon adjacent property, the character of the neighborhood, traffic conditions, parking, utility facilities and other matters affecting the public health, safety, and general welfare The new single-story daycare building is designed at residential scale and character, ensuring no physical impact on adjacent properties beyond what typical residential development would create. In primarily residential areas, daycare facilities rank among the most compatible institutional uses, serving residents' daily needs without compromising residential ambiance. The facility generates approximately 15-20 vehicle trips during peak hours, comparable to or less than a busy single-family residence with multiple drivers. The 6:30 AM-2:00 PM operating schedule avoids typical or traditional residential neighborhood peak hours (7:30-8:30 AM and 5:00-6:30 PM), distributing traffic throughout mid-day periods when residential streets experience lower volumes. Twenty-four on-site parking spaces, supplemented by 44 additional spaces through a shared parking agreement with Elliston Baptist Church, provide a total of 68 spaces, significantly exceeding the 60-space requirement and ensuring parking demand, ensuring no spillover parking impacts on adjacent residential streets—a significant improvement over typical single-family residential parking that often relies on street parking. New utility connections (water, sewer, electrical) are sized appropriately for the daycare's infrastructure needs, comparable to a large single-family residence. The daycare provides essential community infrastructure supporting working families in the neighborhood, enhancing rather than compromising public welfare. The facility operates under strict state licensing requirements ensuring health and safety standards are met. Purpose-built early childhood education facilities represent an ideal transitional use between residential and institutional, serving neighborhood families while maintaining residential scale, appearance, and operational character through thoughtful architectural design. Page 3 of 8 SUP 2026-005 APPROVAL CRITERIA B) The project will be constructed, arranged and operated so as to be compatible with the immediate vicinity and not interfere with the development and use of adjacent property in accordance with the applicable district regulations The new single-story daycare building is specifically designed to maintain residential scale and character appropriate for the R-6 district. At 1,895 square feet, the facility matches the footprint of a single-family home while incorporating design elements that complement neighboring residential architecture. Purpose-built construction allows for optimal site design that respects adjacent property relationships better than retrofitting existing structures. The new construction will not interfere with adjacent residential property development or use rights. Operating hours (6:30 AM-2:00 PM) occur during typical daytime periods when residential properties experience minimal outdoor activity, avoiding conflicts with evening family time, or weekend activities. The new building placement and design does not affect neighboring properties' ability to develop, expand, or modify their residences within R-6 regulations. The new facility is engineered to fully comply with R-6 setback requirements (20-foot front, 10-foot side interior, 20-foot total side, 20-foot rear), establishing appropriate spatial relationships to adjacent properties. The single-story design remains well below the 40-foot R-6 height limit, preserving sight lines and privacy for neighboring homes. The new daycare facility logically completes the established 3-property educational campus without expanding institutional use into the broader residential neighborhood. This concentrated development approach protects surrounding residential blocks from scattered institutional development while creating a cohesive educational node that serves neighborhood families. The facility design enables pedestrian connections that support the integrated educational campus while maintaining compatibility with the residential neighborhood context. The planned playground with Class III buf fering provides acoustic and visual screening compared to typical residential development, ensuring children's outdoor activities enhance rather than impact adjacent residential Page 4 of 8 SUP 2026-005 APPROVAL CRITERIA enjoyment. UDC Sub-Section 9.6.9C Elliston Road provides direct frontage access with demonstrated capacity for the traffic the daycare will generate. The existing elementary and middle school operations on adjacent properties already utilize this street infrastructure for much higher peak traffic loads (300+ students vs. 28 daycare children), proving adequate capacity exists for the minimal additional 15-20 daily trips. Twenty-four dedicated on-site parking spaces, combined with formalized shared parking arrangements providing an additional 44 spaces, eliminating any potential impact on existing school parking or neighborhood street parking, while providing ample capacity for both the daycare and existing elementary school operations representing a net improvement over typical residential development that may often relies on street parking. The single-story building design ensures optimal emergency access, with all areas reachable within 150 feet of fire truck hose deployment from Elliston Road. The purpose-built structure will incorporate modern fire safety systems and clear emergency egress routes, providing emergency response capabilities compared to residential structures. Municipal water and sewer infrastructure serving the adjacent school campus has capacity for the 23-child daycare. The facility's water demand and wastewater generation represent minimal incremental load on existing infrastructure. Adequate electrical service is available from existing utility lines serving the educational campus, with capacity sufficient for the daycare's modest electrical demand. Page 5 of 8 SUP 2026-005 APPROVAL CRITERIA UDC Sub-Section 9.6.9D The project will not result in the destruction, loss or damage of any feature determined to be of significant natural, scenic, or historic importance. The proposed development will not result in the destruction, loss, or damage of any significant natural, scenic, or historic features. The site development has been designed to work with existing topography and preserve existing mature trees where possible. No historic structures or features of significance have been identified on the property. The single-story building design and strategic landscaping ensure no adverse impact on neighborhood scenic character or important viewsheds. The facility's residential-scale architecture and Class II buffer landscaping will enhance rather than detract from the area's visual character. UDC Sub-Section 9.6.9E The proposed daycare meets all additional R-6 district requirements for nonresidential special uses through comprehensive site design that exceeds minimum standards. Building setbacks meet minimum requirements with 20 feet front setback, 10 feet side interior setback, 20 feet total side setback, and 20 feet rear setback, while the single-story height remains well below the 40-foot maximum limit. The Class II landscaping buf fers around future playground area provide enhanced screening. The building coverage ratios maintain residential character appropriate for the R-6 district context. The facility design will incorporate all Tennessee Department of Human Services childcare licensing requirements to ensure optimal child safety and developmental programming. Construction will meet all International Building Code requirements and will also be in full compliance with all ADA requirements. Page 6 of 8 SUP 2026-005 APPROVAL CRITERIA UDC Sub-Section 9.6.9F The proposed daycare aligns comprehensively with the Future Land Use designation of Anchor Neighborhood, which specifically envisions essential community services that support and strengthen primarily residential areas. Early childhood education facilities represent quintessential anchor uses that provide necessary infrastructure for working families while maintaining neighborhood character and residential property values. The facility serves the dual purpose of supporting local economic vitality by enabling parents to participate in the workforce while providing educational services that enhance community desirability and long-term stability. The daycare's design and operational characteristics are fully consistent with existing development standards for adjacent properties within the R-6 district. The single-story, residential-scale building maintains the established setback patterns, height relationships, and architectural character that define the neighborhood's development standards. The facility's integration within the existing educational campus creates a logical institutional cluster that preserves the broader residential character while concentrating compatible community-serving uses in an appropriate location. This approach supports the comprehensive planning goal of providing neighborhood-scale services without compromising residential land use patterns or property values. GIS INFORMATION Case Layer - Central Business Improvement District No Class R Downtown Fire District No Historic District - Land Use SINGLE-F AMILY Municipality MEMPHIS Overlay/Special Purpose District - Zoning R-6 State Route - Lot 0 19 Subdivision EAST MEMPHIS PARK Planned Development District - Wellhead Protection Overlay District Yes County Commission District - Page 7 of 8 SUP 2026-005 GIS INFORMATION City Council District - City Council Super District - Data Tables AREA INFORMATION Name: Leadership Prep Daycare Size (Acres): 0.23 Existing Use of Property: Single Family Residential Requested Use of Property: Daycare Facility Contact Information ETI CORPORATION (901)383-3250 APPLICANT Name Address Phone Contact Type Fee Information Date AssessedBalanceStatusFeesQuantityFee ItemInvoice # 01/30/20260.00INVOICED500.001Special Use Permit Fee - 5 acres or less (Base Fee) 1703715 01/30/20260.00INVOICED250.001Child Care Center (13+ children) 1703715 01/30/20260.00INVOICED19.501Credit Card Use Fee (.026 x fee) 1703715 Total Fee Invoiced : $769.50 Total Balance: $0.00 Payment Information Payment Amount Method of Payment Credit Card$769.50 Page 8 of 8 SUP 2026-005 January 30, 2026 Division of Planning and Development 125 North Main Street, Room 477 Memphis, TN 38103 RE: Letter of Intent and Justif ication - Special Use Permit Application Leadership Preparatory Charter School Proposed Daycare Facility 4180 Elliston Road, Memphis, TN 38111 Leadership Preparatory Charter School respectfully submits this application for a Special Use Permit to establish the Leadership Prep Daycare at 4180 Elliston Road, Memphis, Tennessee 38111. This proposed early childhood education facility will serve as a complementary extension to the existing Leadership Preparatory Charter School campus, which currently operates an elementary and middle school at adjacent properties on Elliston Road. Property Overview and Development Proposal The daycare facility is designed to serve up to twenty-three children ranging from 6 months to 4 years of age, with a staff of seven professionals. The facility will feature three specialized classrooms: an infant room, a toddler room, and a pre-kindergarten room that will provide early educational instruction to prepare children for their academic journey. Operating hours will be from 6:30 AM to 2:00 PM, strategically scheduled to minimize traffic conflicts with the adjacent school’s operating schedule of 8:00 AM to 3:30 PM. While the daycare will prioritize enrollment of children whose parents are employed at the adjacent Leadership Preparatory schools, it will be open to serve the broader community. This approach aligns with the school’s mission of supporting families and contributing to the educational infrastructure of the neighborhood. The subject property is in an R-6 zoning district with a Future Land Use designation of Anchor Neighborhood; Primarily Single-Unit. The property is strategically positioned within an established educational corridor, with the Leadership Preparatory Elementary School immediately to the east, Elliston Baptist Church, and Academy to the south, and single-family residences to the west and north. This context creates a natural educational cluster that enhances the compatibility of the proposed daycare use. The proposed Leadership Prep Daycare fully complies with all R-6 zoning district requirements for non-residential uses. Special Use Permit Justification The following analysis demonstrates that the proposed Leadership Prep Daycare meets all criteria established in the Memphis/Shelby County Unified Development Code for Special Use Permit approval: ENGINEERING • SURVEYING • LAND PLANNING • LANDSCAPE ARCHTECTURE PRINCIPALS Mathew D. Wolfe Christopher E. Perry Douglas M. Baker Steve R. Hooper David M. Docauer Leadership Preparatory Charter School Daycare Facility January 30, 2026 Page 2 of 6 ETI CORPORATION ENGINEERING • SURVEYING • LAND PLANNING • LANDSCAPE ARCHITECTURE 1755 LYNNFIELD ROAD, SUITE 100 • MEMPHIS, TN 38119 • OFFICE (901) 758-0400 • FAX (901 754-5135 • ETICORP.COM A. The project will not have a substantial or undue adverse effect upon adjacent property, the character of the neighborhood, traffic conditions, parking, utility facilities and other matters affecting the public health, safety, and general welfare. The new single-story daycare building is designed at residential scale and character, ensuring no physical impact on adjacent properties beyond what typical residential development would create. In primarily residential areas, daycare facilities rank among the most compatible institutional uses, serving residents' daily needs without compromising residential ambiance. The facility generates approximately 15-20 vehicle trips during peak hours, comparable to or less than a busy single-family residence with multiple drivers. The 6:30 AM-2:00 PM operating schedule avoids typical or traditional residential neighborhood peak hours (7:30-8:30 AM and 5:00-6:30 PM), distributing traffic throughout mid-day periods when residential streets experience lower volumes. Twenty-four on-site parking spaces, supplemented by 44 additional spaces through a shared parking agreement with Elliston Baptist Church, provide a total of 68 spaces, significantly exceeding the 60-space requirement and ensuring parking demand, ensuring no spillover parking impacts on adjacent residential streets—a significant improvement over typical single-family residential parking that often relies on street parking. New utility connections (water, sewer, electrical) are sized appropriately for the daycare's infrastructure needs, comparable to a large single-family residence. The daycare provides essential community infrastructure supporting working families in the neighborhood, enhancing rather than compromising public welfare. The facility operates under strict state licensing requirements ensuring health and safety standards are met. Purpose-built early childhood education facilities represent an ideal transitional use between residential and institutional, serving neighborhood families while maintaining residential scale, appearance, and operational character through thoughtful architectural design. B. The project will be constructed, arranged and operated to be compatible with the immediate vicinity and not interfere with the development and use of adjacent property in accordance with the applicable district regulations. The new single-story daycare building is specifically designed to maintain residential scale and character appropriate for the R-6 district. At 1,895 square feet, the facility matches the footprint of a single-family home while incorporating design elements that complement neighboring residential architecture. Purpose-built construction allows for optimal site design that respects adjacent property relationships better than retrofitting existing structures. The new construction will not interfere with adjacent residential property development or use rights. Operating hours (6:30 AM-2:00 PM) occur during typical daytime periods when residential properties experience minimal outdoor activity, avoiding conflicts with evening family time, or weekend activities. The new building placement and design does not affect neighboring properties' ability to develop, expand, or modify their residences within R-6 regulations. Leadership Preparatory Charter School Daycare Facility January 30, 2026 Page 3 of 6 ETI CORPORATION ENGINEERING • SURVEYING • LAND PLANNING • LANDSCAPE ARCHITECTURE 1755 LYNNFIELD ROAD, SUITE 100 • MEMPHIS, TN 38119 • OFFICE (901) 758-0400 • FAX (901 754-5135 • ETICORP.COM The new facility is engineered to fully comply with R-6 setback requirements (20-foot front, 10- foot side interior, 20-foot total side, 20-foot rear), establishing appropriate spatial relationships to adjacent properties. The single-story design remains well below the 40-foot R-6 height limit, preserving sight lines and privacy for neighboring homes. The new daycare facility logically completes the established 3-property educational campus without expanding institutional use into the broader residential neighborhood. This concentrated development approach protects surrounding residential blocks from scattered institutional development while creating a cohesive educational node that serves neighborhood families. The facility design enables pedestrian connections that support the integrated educational campus while maintaining compatibility with the residential neighborhood context. The planned playground with Class III buffering provides acoustic and visual screening compared to typical residential development, ensuring children's outdoor activities enhance rather than impact adjacent residential enjoyment. C. The project will be served adequately by essential public facilities and services such as streets, parking, drainage, refuse disposal, fire protection and emergency services, water, and sewers; or that the applicant will provide adequately for such services. Elliston Road provides direct frontage access with demonstrated capacity for the traffic the daycare will generate. The existing elementary and middle school operations on adjacent properties already utilize this street infrastructure for much higher peak traffic loads (300+ students vs. 28 daycare children), proving adequate capacity exists for the minimal additional 15- 20 daily trips. Twenty-four dedicated on-site parking spaces, combined with formalized shared parking arrangements providing an additional 44 spaces, eliminating any potential impact on existing school parking or neighborhood street parking, while providing ample capacity for both the daycare and existing elementary school operations representing a net improvement over typical residential development that may often relies on street parking. The single-story building design ensures optimal emergency access, with all areas reachable within 150 feet of fire truck hose deployment from Elliston Road. The purpose-built structure will incorporate modern fire safety systems and clear emergency egress routes, providing emergency response capabilities compared to residential structures. Municipal water and sewer infrastructure serving the adjacent school campus has capacity for the 23-child daycare. The facility's water demand and wastewater generation represent minimal incremental load on existing infrastructure. Adequate electrical service is available from existing utility lines serving the educational campus, with capacity sufficient for the daycare's modest electrical demand. Leadership Preparatory Charter School Daycare Facility January 30, 2026 Page 4 of 6 ETI CORPORATION ENGINEERING • SURVEYING • LAND PLANNING • LANDSCAPE ARCHITECTURE 1755 LYNNFIELD ROAD, SUITE 100 • MEMPHIS, TN 38119 • OFFICE (901) 758-0400 • FAX (901 754-5135 • ETICORP.COM D. The project will not result in the destruction, loss or damage of any feature determined by the governing bodies to be of significant natural, scenic or historic importance. The project will not result in the destruction, loss or damage of any feature determined to be of significant natural, scenic, or historic importance. The proposed development will not result in the destruction, loss, or damage of any significant natural, scenic, or historic features. The site development has been designed to work with existing topography and preserve existing mature trees where possible. No historic structures or features of significance have been identified on the property. The single-story building design and strategic landscaping ensure no adverse impact on neighborhood scenic character or important viewsheds. The facility's residential-scale architecture and Class II buffer landscaping will enhance rather than detract from the area's visual character. E. The project complies with all additional standards imposed on it by any particular provisions authorizing such use. The proposed daycare meets all additional R-6 district requirements for nonresidential special uses through comprehensive site design that exceeds minimum standards. Building setbacks meet minimum requirements with 20 feet front setback, 10 feet side interior setback, 20 feet total side setback, and 20 feet rear setback, while the single-story height remains well below the 40-foot maximum limit. The Class II landscaping buffers around future playground area provide enhanced screening. The building coverage ratios maintain residential character appropriate for the R-6 district context. The facility design will incorporate all Tennessee Department of Human Services childcare licensing requirements to ensure optimal child safety and developmental programming. Construction will meet all International Building Code requirements and will also be in full compliance with all ADA requirements. F. The request will not adversely affect any plans to be considered (see Chapter 1.9) or violate the character of existing standards for development of the adjacent properties. The proposed daycare aligns comprehensively with the Future Land Use designation of Anchor Neighborhood, which specifically envisions essential community services that support and strengthen primarily residential areas. Early childhood education facilities represent quintessential anchor uses that provide necessary infrastructure for working families while maintaining neighborhood character and residential property values. The facility serves the dual purpose of supporting local economic vitality by enabling parents to participate in the workforce while providing educational services that enhance community desirability and long-term stability. The daycare's design and operational characteristics are fully consistent with existing development standards for adjacent properties within the R-6 district. The single-story, residential-scale building maintains the established setback patterns, height relationships, and Leadership Preparatory Charter School Daycare Facility January 30, 2026 Page 5 of 6 ETI CORPORATION ENGINEERING • SURVEYING • LAND PLANNING • LANDSCAPE ARCHITECTURE 1755 LYNNFIELD ROAD, SUITE 100 • MEMPHIS, TN 38119 • OFFICE (901) 758-0400 • FAX (901 754-5135 • ETICORP.COM architectural character that define the neighborhood's development standards. The facility's integration within the existing educational campus creates a logical institutional cluster that preserves the broader residential character while concentrating compatible community-serving uses in an appropriate location. This approach supports the comprehensive planning goal of providing neighborhood-scale services without compromising residential land use patterns or property values. G. The governing bodies may impose conditions to minimize adverse effects on the neighborhood or on public facilities, and to ensure compatibility of the proposed development with surrounding properties, uses, and the purpose and intent of this development code. The applicant acknowledges that the governing bodies may impose reasonable conditions to minimize any potential adverse effects on the neighborhood or public facilities and to ensure complete compatibility with surrounding properties and development code intent. Community Benefits Beyond meeting all regulatory requirements, the Leadership Prep Daycare will provide measurable benefits that enhance community welfare and economic vitality. The facility creates educational continuity by establishing a comprehensive Pre-K through 8th grade educational pathway serving approximately 300+ students across the integrated campus, supporting family stability and student academic success through seamless transitions between developmental stages. This educational continuum reduces family stress and transportation burdens while ensuring consistent educational philosophy and community connections throughout children's formative years. The daycare provides critical employment support infrastructure by enabling families to maintain workforce participation through accessible, quality childcare services. The facility addresses a documented childcare shortage in the area, providing working families with dependable, neighborhood-based early childhood education that reduces commute times and strengthens local economic participation. The project represents new construction investment, demonstrating continued commitment to the neighborhood's educational infrastructure and economic development. This investment enhances property values throughout the surrounding residential area by providing desirable community amenities that make the neighborhood more attractive to families with young children. The facility's integration within the established educational campus creates a valuable community asset that strengthens the area's identity as a family-friendly neighborhood with excellent educational resources, contributing to long-term residential stability and property value appreciation. Conclusion The proposed Leadership Prep Daycare represents a thoughtfully planned addition to the established Leadership Preparatory educational campus that demonstrates comprehensive compatibility with neighborhood character and zoning requirements. The application presents compelling evidence of full compliance with all Special Use Permit criteria established in the Memphis/Shelby County Unified Development Code. The project's design incorporates measurable safeguards to protect adjacent residential uses while providing quantifiable Leadership Preparatory Charter School Daycare Facility January 30, 2026 Page 6 of 6 ETI CORPORATION ENGINEERING • SURVEYING • LAND PLANNING • LANDSCAPE ARCHITECTURE 1755 LYNNFIELD ROAD, SUITE 100 • MEMPHIS, TN 38119 • OFFICE (901) 758-0400 • FAX (901 754-5135 • ETICORP.COM community benefits including educational continuity, employment support for working families, and significant neighborhood investment. We respectfully submit that this comprehensive demonstration of regulatory compliance and community benefit warrants favorable consideration. We are prepared to work collaboratively with city staff throughout the review process to address any questions or concerns that may arise, and we welcome the opportunity to provide additional information if needed. Thank you for your consideration of this important community investment that will provide essential early childhood education infrastructure while preserving and enhancing the residential character of this established neighborhood. Please contact ETI if you need additional information or have any questions. Respectfully submitted, Anita Archambeau, DPA, AICP M:\25036\-10\LETTER OF INTENT.DOC Attachments: N5°40'56"E 200.04' S5°40'56"W 200.00' S84°42'53"E 50.00' N84°45'07"W 50.00' 10' BUILDING SETBACK & CLASS II TYPE A LANDSCAPE SCREEN 10' 20' EX. 25' CURBCUT 20' BUILDING SETBACK 10' BUILDING SETBACK 10' 20' 20' BUILDING SETBACK 10' BUILDING SETBACK & CLASS II TYPE A LANDSCAPE SCREEN PROPOSED DAYCARE FACILITY 1,895 S.F. F.F.E.=268.35 EX. EDUCATIONAL BUILDING TOTAL CLASSROOM S.F. = ±9,620 GROSS BUILDING S.F. = ±14,730 F.F.E.=267.28 FUTURE PLAYGROUND 76.9' 29.7' 23.6' 43.25 EX. SIDEWALK 6-FOOT HEIGHT OPAQUE FENCE EX. PARKING LOT 20 SPACES 44.5' ±22' EXISTING HANDICAP PARKING ELLISTON ROAD 50' R.O.W. WATSON ST. COVERED PATIO EX. 36'' OAK TREE EX. 36'' OAK TREE 6-FOOT HEIGHT OPAQUE FENCE CHAIN LINK FENCE 5' SIDEWALK MARIA CRUZ (I.N. 20103585) LEADERSHIP PREPARATORY CHARTER SCHOOL (I.N. 20040518) JOHNSON BURTON (I.N. 14070522) HERSHEL JONES, JR. (I.N. 07011780) ELLISTON BAPTIST CHURCH & ACADEMY INC. EAST MEMPHIS PARK SUB, P.B. 9 PG. 103 EX. FIRE HYDRANT ±375' TO THE WEST R.O.W LINE OF S. GOODLETT ST. 10.3' 10.2' 10' 16.5' 10' SHARED PARKING AGREEMENT WITH LEADERSHIP PREPARATORY CHARTER SCHOOL 44 PARKING SPACES 50'30' 15' 15' EXISTING SIGN OE OE OE OE OE OE OE OE OE OE OE OE OEOE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE PP PP PP PP PP EX. OVERHEAD ELECTRIC EX. OVERHEAD ELECTRIC SCHOOL PROPERTY LINE SCHOOL PROPERTY LINE 6' SIDEWALK EX. SIDEWALK 10' BUILDING SETBACKEX. 24'' PECAN VICINTY MAP SITE PLAN NORTH SCALE: 1" = 20' 20 10 0 20 40 SHEET 1 OF 3SHEET ZONING: R-6 MEMPHIS, TENNESSEE NUMBER OF LOTS: 01 ACREAGE: 0.2296 ACRES DEVELOPER: 100-YEAR FLOOD ELEVATION: ENGINEER : FEMA MAP PANEL NUMBER: SCALE: 1" = 20' FEMA MAP DATE: 47157C0435F SEPTEMBER 28, 2007 ETI CORPORATION 1755 LYNNFIELD ROAD, SUITE 100 MEMPHIS, TN. 38119 - LEADERSHIP PREPARATORY CHARTER SCHOOL 4190 ELLISTON ROAD MEMPHIS, TN 38111 WARD ___, BLOCK ___, PARCELS ____ 58 161 30 DATE: JANUARY 2026 CASE NUMBER: SUP FINAL PLAT LEADERSHIP PREPARATORY CHARTER SCHOOL SITE DATA CHART PROPERTY ZONING: R-6 PROPERTY USE: DAY CARE PROPOSED PROPERTY ACREAGE: 0.23 ACRES DAY CARE GROSS SPACE: 1,895 S.F. TOTAL INDIVIDUAL OCCUPANCY: 30 PARKING REQUIRED (1 Space/5 Indiv.): 6 SPACES EX. ELEMENTARY CLASSROOM TOTAL S.F.: ±9,620 PARKING REQUIRED (1 SPACE/300 S.F.): 32 SPACES ONSITE PARKING PROVIDED: 24 SPACES OFFSITE PARKING PROVIDED: 44 SPACES (ELLISTON BAPTIST CHURCH) FRONT YARD BUILDING SETBACK: 20-FEET SIDE YARD BUILDING SETBACK: 10-FEET REAR YARD BUILDING SETBACK: 20-FEET SITE City Hall – 125 N. Main Street, Suite 468 – Memphis, Tennessee 38103 – (901) 636-6619 March 12, 2026 Doug Baker ETI Corporation 1755 Lynnfield Road, Suite 100 Memphis, TN 38119 Sent via electronic mail to: dbaker@eticorp.com Case Number: SUP 2026-0005 LUCB Recommendation: Approval with conditions Dear applicant, On Thursday, March 12, 2026 , t he Memphis and Shelby County Land Use Control Board recommended approval of your special use permit application to allow a childcare center located at 4180 Elliston Road subject to the following conditions: 1. The exact location of the crosswalk shall be determined and approved by the City Engineer via the Administrative Site Plan Review (ASPR) process. 2. A Class III Buffer shall be provided along the western property line. An alternative buffer may be approved through the site plan review process by the Division of Planning and Development. 3. A final site/landscape plan shall be submitted subject to the review and approval of the Division of Planning and Development. This application will be forwarded, for final action, to the Council of the City of Memphis. The Council will review your application in a committee meeting prior to voting on it in a public hearing. The applicant or the applicant’s representative(s) shall be in attendance at all meetings and hearings. It is the applicant’s responsibility to contact the City Council Records Office to determine when the application is scheduled to be heard at committee and in public session. The City Council Records Office may be reached at (901) 636-6792. If for some reason you choose to withdraw your application, a letter should be mailed to the Land Use and Development Services Department of the Division of Planning and Development at the address provided above or emailed to the address provided below. Letter to Applicant SUP 2026-0005 Page 2 of 2 If you have questions regarding this matter, please feel free to contact me at (901) 636-6619 or via email at chloe.christion@memphistn.gov. Respectfully, Chloe Christion Planner II Land Use and Development Services Division of Planning and Development Cc: Anita Archambeau – ETI Corporation Matt Wolfe – ETI Corporation Valissia Allen – Lead Memphis File Memphis City Council Summary Sheet Z 2026-001 ZONING ORDINANCE AMENDING ORDINANCE NO. 5367 OF CODE OF ORDINANCE, CITY OF MEMPHIS, TENNESSEE, ADOPTED ON AUGUST 10, 2010, AS AMENDED, KNOWN AS THE MEMPHIS AND SHELBY COUNTY UNIFIED DEVELOPMENT CODE, TO AUTHORIZE A ZONING USE DISTRICT RECLASSIFICATION FOR LAND LOCATED ON TULLY STREET AND WOODLAWN STREET. BY TAKING THE LAND OUT OF THE RESIDENTIAL URBAN – 1 (RU-1) USE DISTRICT AND INCLUDING IT IN THE MIXED USE (MU) USE DISTRICT, KNOWN AS CASE NUMBER Z 2026-001 • Approval of this zoning district reclassification will be reflected on the Memphis and Shelby County Zoning Atlas; and • No contracts are affected by this item; and • No expenditure of funds/budget amendments are required by this item. 1 LAND USE CONTROL BOARD RECOMMENDATION At its regular meeting on Thursday, February 12, 2026, the Memphis and Shelby County Land Use Control Board held a public hearing on the following application: CASE NUMBER: Z 2026-001 LOCATION: Tully Street and Woodlawn Street COUNCIL DISTRICT(S): District 7, Super District 8 – Positions 1, 2, and 3 OWNER/APPLICANT: LC Wallace – Elmington Capital Group REPRESENTATIVE: Owen Harris – Kimley-Horn Associates REQUEST: Rezoning of +/-3.3 acres from Residential Urban – 1 (RU-1) to Mixed Use (MU) The following spoke in support: None The following spoke in opposition: None The Land Use Control Board reviewed the application and the staff report . A motion was made and seconded to recommend approval of the application. The motion passed by a unanimous vote of 9-0 on the consent agenda. Respectfully, Cc: Committee Members File 2 PLOT PLAN 3 CONCEPT PLAN 4 EXAMPLE ARCHITECTURE DESIGN ORDINANCE NO: ____________ ZONING ORDINANCE AMENDING ORDINANCE NO. 5367 OF CODE OF ORDINANCE, CITY OF MEMPHIS, TENNESSEE, ADOPTED ON AUGUST 10, 2010, AS AMENDED, KNOWN AS THE MEMPHIS AND SHELBY COUNTY UNIFIED DEVELOPMENT CODE, TO AUTHORIZE A ZONING USE DISTRICT RECLASSIFICATION FOR LAND LOCATED ON THE WEST SIDE OF SWINNEA ROAD +/ -2,645 FEET SOUTH OF HOLMES ROAD. BY TAKING THE LAND OUT OF THE RESIDENTIAL URBAN – 1 (RU-1) USE DISTRICT AND INCLUDING IT IN THE MIXED USE (MU) USE DISTRICT, KNOWN AS CASE NUMBER Z 2026-001 WHEREAS, a proposed amendment to the Memphis and Shelby County Unified Development Code, being Ordinance No. 5367 of the Code of Ordinances, City of Memphis, Tennessee, as amended, has been submitted to the Memphis and Shelby County Land Use Cont rol Board for its recommendation , designated as Case Number: Z 2026-001; and WHEREAS, the Memphis and Shelby County Land Use Control Board has filed its recommendation and the Division of Planning and Development has filed its report and recommendation with the Council of the City of Memphis; and WHEREAS, the Council of the City of Memphis has reviewed the aforementioned amendment pursuant to Tennessee Code Annotated Section 13 -4-202(B)(2)(B)(iii) and has determined that said amendment is consistent with the Memphis 3.0 General Plan; and WHEREAS, the provisions of the Code of Ordinances, City of Memphis, Tennessee, as amended, relating to the proposed amendment, have been complied with. NOW THERE FORE, BE IT ORDAINED , BY THE COUNCIL OF THE CITY OF MEMPHIS: SECTION 1: THAT, the Memphis and Shelby County Unified Development Code, Ordinance No. 5367 of the Code of Ordinances, City of Memphis, as amended, be and the same hereby is amended with respect to Use Districts, as follows: BY TAKING THE FOLLOWING PROPERTY OUT OF THE Residential Urban – 1 (RU-1) USE DISTRICT AND INCLUDING IT IN THE Mixed Use (MU) USE DISTRICT. The following property located in the City of Memphis, Tennessee being more particularly described as follows: LEGAL DESCRIPTION BEGINNING AT A POINT IN THE WEST LINE OF WOODLAWN STREET (60 FEET RIGHT OF WAY), 85.11 FEET NORTH OF THE NORTH LINE OF CHELSEA AVENUE (80 FEET RIGHT OF WAY), BEING IN THE NORTH LINE OF THE LARRY BLAND PROPERTY AS DESCRIBED IN INSTRUMENT BH 1636, BEING THE NORTH LINE OF LOT 73, SNOWDEN AND BRINKLEY SUBDIVISION AS RECORDED IN PLAT BOOK 3 PAGE 38; THENCE NORTH 09 DEGREES 23 MINUTES 26 SECONDS EAST ALONG THE WEST LINE OF WOODLAWN STREET A DISTANCE OF 300.00 FEET TO THE SOUTH LINE OF THE MDM INVESTMENTS, LLC PROPERTY AS DESCRIBED IN INSTRUMENT 21016675 AND BEING THE SOUTH LINE OF LOT 80, SNOWDEN AND BRINKLEY SUBDIVISION; THENCE NORTH 80 DEGREES 08 MINUTES 55 SECONDS WEST ALONG THE NORTH LINE OF LOT 79 AND LOT 58, SNOWDEN AND BRINKLEY SUBDIVISION, A DISTANCE OF 400.04 FEET; THENCE SOUTH 09 DEGREES 20 MINUT ES 59 SECONDS WEST ALONG THE EAST LINE OF TULLY STREET A DISTANCE OF 436.94 FEET TO THE NORTH LINE OF THE MDM INVESTMENTS, LLC PROPERTY AS DESCRIBED IN INSTRUMENT 20103237; THENCE SOUTH 80 DEGREES 18 MINUTES 58 SECONDS EAST A DISTANCE OF 100.00 FEET; THENCE NORTH 09 DEGREES 20 MINUTES 59 SECONDS EAST A DISTANCE OF 36.20 FEET; THENCE SOUTH 80 DEGREES 18 MINUTES 58 SECONDS EAST ALONG THE NORTH LINE OF LOT 68 AND LOT 69, SNOWDEN AND BRINKLEY SUBDIVISION, A DISTANCE OF 100.00 FEET; THENCE NORTH 09 DEGREES 20 MI NUTES 59 SECONDS EAST ALONG THE WEST LINE OF LOT 70, SNOWDEN AND BRINKLEY SUBDIVISION, A DISTANCE OF 100.16 FEET; THENCE SOUTH 80 DEGREES 08 MINUTES 54 SECONDS EAST ALONG THE NORTH LINE OF LOT 70 AND LOT 71, SNOWDEN AND BRINKLEY SUBDIVISION, A DISTANCE OF 99.82; THENCE SOUTH 80 DEGREES 08 MINUTES 54 SECONDS EAST ALONG THE NORTH LINE OF LOT 72 AND LOT 73, SNOWDEN AND BRINKLEY SUBDIVISION, A DISTANCE OF 100.00 FEET TO THE POINT OF BEGINNING, CONTAINING 143,686.31 SQUARE FEET / 3.30 ACRES MORE OR LESS. SECTION 2: THAT, the Zoning Administrator of the Division of Planning and Development be, and is hereby directed to make the necessary changes in the Official Use District Maps to conform to the changes herein made; that all official maps and records of the Memphis and Shelby County Land Use Control Board and the City of Memphis be, and they hereby are, amended and changed so as to show the aforementioned amendment of the said Zoning Ordinance. SECTION 3: THAT, this ordinance take effect from and after the date it shall have been passed by the Council, signed by the Chairman of the Council, certified and delivered to the Office of the Mayor in writing by the comptroller, and become effective as otherwise provided by law. PLOT PLAN CONCEPT PLAN EXAMPLE ARCHITECTURE DESIGN ATTEST: CC: Division of Planning and Development – Land Use and Development Services – Office of Construction Enforcement Shelby County Assessor Staff Writer: Mahsan Ostadnia E-mail: mahsan.ostadnia@memphistn.gov AGENDA ITEM: 13 L.U.C.B. MEETING: February 12, 2026 CASE NUMBER: Z 2026-001 LOCATION: Tully Street and Woodlawn Street COUNCIL DISTRICT: District 7 and Super District 8 OWNER/APPLICANT: LC Wallace – Elmington Capital Group REPRESENTATIVE: Owen Harris – Kimley-Horn Associates REQUEST: Rezoning of +/-3.3 acres from Residential Urban – 1 (RU-1) to Mixed Use (MU) CONCLUSIONS 1. The applicant proposes to rezone multiple parcels totaling approximately 3.30 acres located within the Brinkley and Snowden Subdivision, currently zoned Residential Urban – 1 (RU -1). Based on Assessor records, most of the subject parcels are vacant. The surrounding area is predominantly single-family residential, interspersed with vacant lots, and the proposed rezoning area has frontage on two public streets, offering opportunities for improved access and site organization. 2. The request seeks to extend the existing Mixed -Use zoning designation along Chelsea Avenue to include the subject parcels, if approved, the applicant would end up 4.39 acres of land zoned MU enabling development of their proposed multi-family residential p roject. The request seeks to extend the existing Mixed -Use zoning designation along Chelsea Avenue to include the subject parcels, enabling development of a multi -family residential project. The proposed development would introduce approximately 158 multi-family units, consisting of a mix of two, three, and four-bedroom units, and would consolidate several underutilized parcels into a cohesive residential development. The current RU -1 zoning does not permit multi -family development at the proposed density, and the requested rezoning would provide the necessary bulk and dimensional standards to accommodate the project. See page 10 for the concept plan. 3. Based on the conceptual site plan and applicable provisions of the Unified Development Code, the proposed development generally meets the Contextual Infill standards related to bulk, form, and site organization. The proposal introduces multi- family buildings at a scale and intensity anticipated within the Anchor Neighborhood – Mix of Building Types designation, with building placement oriented toward public streets and internal circulation designed to limit impacts on adjacent residential properties. The re quested rezoning would provide the bulk and dimensional standards necessary to accommodate the proposed development. While final compliance with setbacks, building height, lot coverage, landscaping, and parking placement will be evaluated during site plan review, the conceptual layout demonstrates consistency with the UDC’s intent to ensure compatible massing, appropriate transitions, and cohesive infill development within established neighborhoods. 4. The proposed rezoning is consistent with adopted planning policies, including Memphis 3.0 and the Uptown Community Plan, which promote redevelopment of vacant and underutilized parcels, increased housing opportunities, and reinforcement of neighborhood character near community anchors. The request aligns with the “Accelerate” Degree of Change and the Anchor Neighborhood – Mix of Building Types designation by supporting residential infill and extending mixed-use zoning along Chelsea Avenue. The proposal woul d facilitate reinvestment in a largely vacant area, improve streetscape continuity, and support increased neighborhood activity while remaining compatible with surrounding residential and mixed-use development patterns. CONSISTENCY WITH MEMPHIS 3.0 This proposal is consistent with the Memphis 3.0 General Plan per the land use decision criteria. See further analysis on pages 18-21 of this report. RECOMMENDATION: Approval Staff Report February 12, 2026 Z 2026-001 Page 2 2 LOCATION MAP Subject property located within the pink circle. SUBJECT PROPERTY Staff Report February 12, 2026 Z 2026-001 Page 3 3 PUBLIC NOTICE VICINITY MAP Subject property highlighted in yellow. PUBLIC NOTICE DETAILS In accordance with Sub-Section 9.3.4A of the Unified Development Code, a notice of public hearing is required to be mailed and signage posted. A total of 203 notices were mailed on January 1 2, 2026, see page 22 of this report for a copy of said notice. Additionally, two signs were posted at the subject property, see pages 23-24 of this report for a copy of the sign affidavit. NEIGHBORHOOD MEETING The meeting was held at 5:00 PM on Monday, February 2, 2026, at Dave Well Community Center at 915 Chelsea Avenue, Memphis, TN 38107. See pages 32-33 of this report for a copy of the neighborhood meeting summary. Staff Report February 12, 2026 Z 2026-001 Page 4 4 AERIAL Subject property outlined in yellow. Staff Report February 12, 2026 Z 2026-001 Page 5 5 ZONING MAP Subject property highlighted in yellow. Staff Report February 12, 2026 Z 2026-001 Page 6 6 LAND USE MAP Subject property indicated by a pink star. Staff Report February 12, 2026 Z 2026-001 Page 7 7 SITE PHOTOS View of subject property from Tully Street. View of subject property from Woodlawn Street. Staff Report February 12, 2026 Z 2026-001 Page 8 8 View of subject property from above. View of subject property from above. Staff Report February 12, 2026 Z 2026-001 Page 9 9 PLOT PLAN Staff Report February 12, 2026 Z 2026-001 Page 10 10 CONCEPT PLAN Staff Report February 12, 2026 Z 2026-001 Page 11 11 EXAMPLE ARCHITECTURE DESIGN Staff Report February 12, 2026 Z 2026-001 Page 12 12 LEGAL DESCRIPTION Staff Report February 12, 2026 Z 2026-001 Page 13 13 CASE REVIEW Request The request is a Rezoning of +/-3.3 acres from Residential Urban – 1 (RU-1) to Mixed Use (MU). Review Criteria Staff agrees the review criteria as set out in Sub-Section 9.5.7B of the Unified Development Code are met. 9.5.7B Review Criteria In making recommendations, the Land Use Control Board shall consider the following matters: 9.5.7B(1) Consistency with any plans to be considered (see Chapter 1.9); 9.5.7B(2) Compatibility with the present zoning (including any residential corridor overlay district) and conforming uses of nearby property and with the character of the neighborhood; 9.5.7B(3) Suitability of the subject property for uses permitted by the current versus the proposed district; 9.5.7B(4) Whether the proposed change tends to improve the balance of uses, or meets a specific demand in the City or County; and 9.5.7B(5) The availability of adequate police services, fire services, school, road, park, wastewater treatment, water supply and stormwater drainage facilities for the proposed zoning. Site Details Address: Tully Street and Woodlawn Street Parcel ID: 027004 00033, 027004 00034, 027004 00035, 027004 00036, 027004 00037, 027004 00038, 027004 00017C, 027004 00018C, 027004 00020, 027004 00021, 027004 00022, 027004 00023, 027004 00024 Area: +/- 4.39 acres Description: The proposed parcels are known as part of Brinkley and Snowden Subdivision with a zoning of Residential Urban – 1 (RU-1). Per the Assessor’s website, most of these lots are vacant. The proposed parcels for rezoning are 3.30 acres in total. The surrounding land uses are a mixture of single -family and vacant lots. Additionally, the proposed area has two street frontages. Analysis The applicant proposes to rezone multiple parcels totaling approximately 3.30 acres located within the Brinkley and Snowden Subdivision, currently zoned Residential Urban – 1 (RU-1). Based on Assessor records, most of the subject parcels are vacant. The su rrounding area is predominantly single -family residential, interspersed with vacant lots, and the proposed rezoning area has frontage on two public streets, offering opportunities for improved access and site organization. The request seeks to extend the existing Mixed -Use zoning designation along Chelsea Avenue to include the subject parcels, if approved, the applicant would end up 4.39 acres of land zoned MU enabling development of their proposed multi -family residential p roject. The request seeks to extend the existing Mixed -Use zoning Staff Report February 12, 2026 Z 2026-001 Page 14 14 designation along Chelsea Avenue to include the subject parcels, enabling development of a multi -family residential project. The proposed development would introduce approximately 158 multi -family units, consisting of a mix of two, three, and four -bedroom units, and would consolidate several underutilized parcels into a cohesive residential development. The current RU-1 zoning does not permit multi-family development at the proposed density, and the requested rezoning would provide the necessary bulk and dimensional standards to accommodate the project. See page 10 for the concept plan. Based on the conceptual site plan and applicable provisions of the Unified Development Code, the proposed development generally meets the Contextual Infill standards related to bulk, form, and site organization. The proposal introduces multi-family buildings at a scale and intensity anticipated within the Anchor Neighborhood – Mix of Building Types designation, with building placement oriented toward public streets and internal circulation designed to limit impacts on adjacent residential properties. The re quested rezoning would provide the bulk and dimensional standards necessary to accommodate the proposed development. While final compliance with setbacks, building height, lot coverage, landscaping, and parking placement will be evaluated during site plan review, the conceptual layout demonstrates consistency with the UDC’s intent to ensure compatible massing, appropriate transitions, and cohesive infill development within established neighborhoods. The proposed rezoning is consistent with adopted planning policies, including Memphis 3.0 and the Uptown Community Plan, which promote redevelopment of vacant and underutilized parcels, increased housing opportunities, and reinforcement of neighborhood character near community anchors. The request aligns with the “Accelerate” Degree of Change and the Anchor Neighborhood – Mix of Building Types designation by supporting residential infill and extending mixed-use zoning along Chelsea Avenue. The proposal would facilitate reinvestment in a largely vacant area, improve streetscape continuity, and support increased neighborhood activity while remaining compatible with surrounding residential and mixed-use development patterns. RECOMMENDATION Staff recommends approval. Staff Report February 12, 2026 Z 2026-001 Page 15 15 DEPARTMENTAL COMMENTS The following comments were provided by agencies to which this application was referred: City Engineer: See page 16. County Engineer: No comments received. City Fire Division: See page 17. County Fire Division: No comments received. City Real Estate: No comments received. County Health Department: No comments received. Shelby County Schools: No comments received. Construction Code Enforcement: No comments received. Memphis Light, Gas and Water: No comments received. Office of Sustainability and Resilience: No comments received. Office of Comprehensive Planning: See pages 18-21. Staff Report February 12, 2026 Z 2026-001 Page 16 16 City Engineer: 1. Standard Public Improvement Contract or Right -Of-Way Permit as required in Section 5.5.5 of the Unified Development Code. Sewers: 2. The availability of City sanitary sewer is unknown at this time. Once the developer has submitted proposed sewer discharge rates to the City’s Sewer Design Dept, a determination can be made as to available sewer capacity. Roads: 3. The Developer shall be responsible for the repair and/or replacement of all existing curb and gutter along the frontage of this site as necessary. 4. All existing sidewalks and curb openings along the frontage of this site shall be inspected for ADA compliance. The developer shall be responsible for any reconstruction or repair necessary to meet City standards. Traffic Control Provisions: 5. The developer shall provide a traffic control plan to the city engineer that shows the phasing for each street frontage during demolition and construction of curb gutter and sidewalk. Upon completion of sidewalk and curb and gutter improvements, a minimum 5 foot wide pedestrian pathway shall be provided throughout the remainder of the project. In the event that the existing right of way width does not allow for a 5 -foot clear pedestrian path, an exception may be considered. 6. Any closure of the right of way shall be time limited to the active demolition and construction of sidewalks and curb and gutter. Continuous unwarranted closure of the right of way shall not be allowed for the duration of the project. The developer shall provide on the traffic control plan, the time needed per phase to complete that portion of the work. Time limits will begin on the day of closure and will be monitored by the Engineering construction inspectors on the job. 7. The developer’s engineer shall submit a Trip Generation Report that documents the proposed land use, scope and anticipated traffic demand associated with the proposed development. A detailed Traffic Impact Study will be required when the accepted Trip Generation Report indicates that the number for projected trips meets or exceeds the criteria listed in Section 210 -Traffic Impact Policy for Land Development of the City of Memphis Division of Engineering Design and Policy Review Manual. Any required Traffic Impact Study will need to be formally approved by the City of Memphis, Traffic Engineering Department. Curb Cuts/Access: 8. The City Engineer shall approve the design, number, and location of curb cuts. 9. Any existing nonconforming curb cuts shall be modified to meet current City Standards or closed with curb, gutter, and sidewalk. 10. Will require engineering ASPR. Staff Report February 12, 2026 Z 2026-001 Page 17 17 City Fire Division: 1. All design and construction shall comply with the 2021 edition of the International Fire Code with local amendments and referenced standards. 2. Fire apparatus access shall comply with section 503. 3. Where security gates are installed that affect required fire apparatus access roads, they shall comply with section 503.6. 4. Fire protection water supplies (including fire hydrants) shall comply with section 507. 5. Where fire apparatus access roads or a water supply for fire protection are required to be installed, such protection shall be installed and made serviceable prior to and during the time of construction except when approved alternate methods of protection are provided. 6. IFC 510 In-building two-way emergency responder communication coverage shall be provided in all new and existing buildings. Buildings and structures that cannot support the required level of coverage shall be equipped with systems and components to enhance signals and achieve the required level of communication coverage. 7. A detailed plans review will be conducted by the Memphis Fire Prevention Bureau upon receipt of complete construction documents. Plans shall be submitted to the Shelby County Office of Code Enforcement. Staff Report February 12, 2026 Z 2026-001 Page 18 18 Office of Comprehensive Planning: This summary is being produced in response to the following application to support the Land Use and Development Services department in their recommendation: Z 2026-001 Site Address/Location: 896 Tully. The site includes 22 parcels bounded by Woodlawn to the East, Chelsea to the South, and Thomas to the West. The northern boundary is with parcels 027004 00040 and 027004 00016. Overlay District/Historic District/Flood Zone: Not in an Overlay District, Historic District, or Flood Zone Future Land Use Designation: Anchor Neighborhood-Mix of Building Types (AN-M) Street Type: Avenue, Local Neighborhood Streets Applicant is seeking a Rezoning to expand the MU district along Chelsea to include parcels further along Tully and Woodlawn for a large Multi-Family development. The following information about the land use designation can be found on pages 76 – 122: 1. Future Land Use Planning Map Red polygon indicates the application site on the Future Land Use Map. 2. Land Use Description/Intent Anchor Neighborhood -Mix of Building Types (AN -M) are walkable neighborhoods within a 5 – 10-minute walk of a Community Anchor. These neighborhoods are made up of a mix of single -unit and multi -unit housing. Graphic portrayal of AN-M is to the right. Staff Report February 12, 2026 Z 2026-001 Page 19 19 “AN-M” Form & Location Characteristics ACCELERATE: Primarily detached, single-family house-scale residences of 1-3 stories in height. Attached, house- scale single-family, duplexes, triplexes and quadplexes of 1 -3 stories in height permitted on parcels within 200 feet of an anchor and at inters ections where the presence of such housing type currently exists. Building -scale large homes and apartments of 2 -4 stories in height permitted on parcels within 100 feet of an anchor; at intersections where the presence of such housing type currently exist s at the intersection. Other housing and commercial types along avenues, boulevards and parkways as identified in the Street Types Map where same types exist on one or more adjacent parcels. “AN-M” Zoning Notes Generally compatible with the following zone districts: RU -2, RU-3, RU-4, R-SD, R-R, MDR, and CMU -1 when located along avenues, boulevards, and parkways as identified in the Street Types Map, in accordance with Form and characteristics listed above. Existing, Adjacent Land Use and Zoning Existing Land Use and Zoning: Vacant, Multi-family; RU-1, MU. Adjacent Land Use and Zoning: Single-Family, Multi-Family, Institutional, Commercial, Office; RU-1, MU. Overall Compatibility: This requested use is compatible with the land use description/intent, form & location characteristics, the zoning notes, and existing/adjacent land use and zoning. Expanding access to housing is consistent with accelerating the activity at the nearby Chelsea and Thomas anchor. 3. Degree of Change Map Red polygon denotes the proposed site in Degree of Change area. Degree of Change is Accelerate. Staff Report February 12, 2026 Z 2026-001 Page 20 20 4. Degree of Change Description Accelerate areas rely on a mix of primarily private and philanthropic resources along with some public resources to intensify the existing pattern of a place. The proposed building is a private investment and infill development that supports the anchor neighborhood. Pages 65 – 67. 5. Objectives/Actions Consistent with Goal 1, Complete, Cohesive, Communities The proposed development is consistent with Objective 1.1 – Focus future growth and density in and around Community and Citywide Anchors Action 1.1.30 – Incentivise housing and employment growth to occur arounding Citywide and Community Anchors and high frequency transit corridors, preserving and integrating existing affordable housing where possible. The development increases housing choice and density to support the Chelsea and Thomas anchor along MATA’s Bus Route 8. 6. Pertinent Sections of Memphis 3.0 that Address Land Use Recommendations The development is consistent with Objective 1.3 – Develop strategies that reduce blight and vacancy Action 1.3.7 – Focus redevelopment efforts for vacant parcels within one -quarter mile of anchors (anchor neighborhoods). The existing property is mostly vacant land directly adjacent to the Chelsea and Thomas anchor. Development of these properties into more housing will support any future activity at this anchor. Consistency Analysis Summary Applicant is seeking a Rezoning to expand the MU district along Chelsea to include parcels further along Tully and Woodlawn for a large Multi-Family development. This requested use is compatible with the land use description/intent, form & location characteristics, the zoning notes, and existing/adjacent land use and zoning. Expanding access to housing is consistent with accelerating the activity at the nearby Chelsea and Thomas anchor. The proposed building is a private investment and infill development that supports the anchor neighborhood. Pages 65 – 67. The proposed development is consistent with Objective 1.1 – Focus future growth and density in and around Community and Citywide Anchors Action 1.1.30 – Incentivise housing and employment growth to occur arounding Citywide and Community Anchors and high frequency transit corridors, preserving and integrating existing affordable housing where possible. The development is consistent with Objective 1.3 – Develop strategies that reduce blight and vacancy Action 1.3.7 – Focus redevelopment efforts for vacant parcels within one -quarter mile of anchors (anchor neighborhoods). Additional Comments While the development is consistent, we recommend any effort to reduce parking should be made as over 2 acres of surface parking in an Anchor Neighborhood is not consistent with supporting neighborhood walkability/connectivity. Reducing parking amount/requirements is consistent with Objective 4.2 – Promote safe movement of people and vehicles across all modes of travel Action 4.2.2 – Prioritize pedestrian and bicycle improvements within Staff Report February 12, 2026 Z 2026-001 Page 21 21 anchors and anchor neighborhoods, starting with accelerate anchors. The inclusion of 1.39 spaces per unit assumes each unit will have access to a vehicle. Increasing vehicle access will directly reduce transit ridership, which is inconsistent with the Anchor strategy. The development’s increase in density should focus more support towards transit routes along the Chelsea corridor. Based on the information provided, the proposal is CONSISTENT with the Memphis 3.0 Comprehensive Plan. Staff Report February 12, 2026 Z 2026-001 Page 22 22 MAILED PUBLIC NOTICE Staff Report February 12, 2026 Z 2026-001 Page 23 23 SIGN AFFIDAVIT Staff Report February 12, 2026 Z 2026-001 Page 24 24 Staff Report February 12, 2026 Z 2026-001 Page 25 25 PROJECT MEMORANDUM Staff Report February 12, 2026 Z 2026-001 Page 26 26 Staff Report February 12, 2026 Z 2026-001 Page 27 27 Staff Report February 12, 2026 Z 2026-001 Page 28 28 Staff Report February 12, 2026 Z 2026-001 Page 29 29 Staff Report February 12, 2026 Z 2026-001 Page 30 30 Staff Report February 12, 2026 Z 2026-001 Page 31 31 Staff Report February 12, 2026 Z 2026-001 Page 32 32 NEIGHBORHOOD MEETING SUMMARY Staff Report February 12, 2026 Z 2026-001 Page 33 33 Staff Report February 12, 2026 Z 2026-001 Page 34 34 APPLICATION Staff Report February 12, 2026 Z 2026-001 Page 35 35 Staff Report February 12, 2026 Z 2026-001 Page 36 36 Staff Report February 12, 2026 Z 2026-001 Page 37 37 Staff Report February 12, 2026 Z 2026-001 Page 38 38 Staff Report February 12, 2026 Z 2026-001 Page 39 39 Staff Report February 12, 2026 Z 2026-001 Page 40 40 OWNER AFFIDAVIT Staff Report February 12, 2026 Z 2026-001 Page 41 41 Staff Report February 12, 2026 Z 2026-001 Page 42 42 Staff Report February 12, 2026 Z 2026-001 Page 43 43 Staff Report February 12, 2026 Z 2026-001 Page 44 44 LETTER OF INTENT Staff Report February 12, 2026 Z 2026-001 Page 45 45 LETTERS RECEIVED No letters received at the time of completion of this report. East Service Center: 6465 Mullins Station Rd; Memphis, Tennessee 38134 Downtown Service Center: 125 N. Main Street; Memphis, T ennessee 38103 website: www.develop901.com Memphis and Shelby County Division of Planning and Development Record Summary for Rezoning Record Detail Information Record T ype: Rezoning Record Status: Pending Opened Date: January 2, 2026 Record Number: Z 2026-001 Record Name: Chelsea Avenue Project Expiration Date: Description of Work: This application requests that thirteen Residential Urban (RU-1) parcels be rezoned to Mixed-Use (MU). The rezoning of these parcels will allow for a high-quality residential development along the Chelsea Avenue corridor in the Uptown Neighborhood. Parent Record Number: Address: 896 TULLY ST, MEMPHIS 38107 Owner Information Primary Owner Name Owner Address Owner Phone Y DAVIS KARLEN AND DICKERSON WELLS AND 5100 POPLAR AVE, MEMPHIS, TN 38137 Parcel Information 027004 00035 Data Fields PREAPPLICA TION MEETING Name of DPD Planner Jeffrey Penzes Date of Meeting 12/04/2025 Pre- application Meeting Type In Person GENERAL INFORMATION Have you held a neighborhood meeting? No Is this application in response to a citation from Construction Code Enforcement or Zoning Letter? No Page 1 of 4 Z 2026-001 GENERAL INFORMATION If yes, please provide additional information - GIS INFORMATION Case Layer Z88-157, Z88-157 Central Business Improvement District No Class R Downtown Fire District No Historic District - Land Use VACANT Municipality MEMPHIS Overlay/Special Purpose District - Zoning MU State Route - Lot 62-64 Subdivision BRINKLEY & SNOWDEN S/D Planned Development District - Wellhead Protection Overlay District Yes County Commission District - City Council District - City Council Super District - Data Tables ADDRESS AND PARCEL LIST Property Address: 874 TULLY ST Property Parcel Number: 027004 00033 Property Address: 880 TULLY ST Property Parcel Number: 027004 00034 Property Address: 894 TULLY Property Parcel Number: 027004 00035 Property Address: 902 TULLY ST Property Parcel Number: 027004 00036 Property Address: 906 TULLY ST Property Parcel Number: 027004 00037 Property Address: 910 TULLY ST Property Parcel Number: 027004 00038 Property Address: 916 N TULLY ST Property Parcel Number: 027004 00017C Property Address: 915 WOODLAWN Property Parcel Number: 027004 00018C Page 2 of 4 Z 2026-001 Property Address: 909 WOODLAWN ST Property Parcel Number: 027004 00020 Property Address: 905 WOODLAWN ST Property Parcel Number: 027004 00021 Property Address: 899 WOODLAWN ST Property Parcel Number: 027004 00022 Property Address: 897 WOODLAWN Property Parcel Number: 027004 00023 Property Address: 889 WOODLAWN Property Parcel Number: 027004 00024 Contact Information LC WALLACE - APPLICANT Name Address Phone Contact Type OWEN HARRIS (901)245-4482 ARCHITECT / ENGINEER / SURVEYOR Name Address Phone Contact Type OWEN HARRIS (901)245-4482 REPRESENTATIVE Name Address Phone Contact Type Fee Information Date AssessedBalanceStatusFeesQuantityFee ItemInvoice # 01/02/20260.00INVOICED1,000.001Non-Residential Rezoning - 5 acres or less 1699113 01/02/20260.00INVOICED26.001Credit Card Use Fee (.026 x fee) 16991 13 Total Fee Invoiced: $1,026.00 Total Balance: $0.00 Payment Information Payment Amount Method of Payment Credit Card$1,026.00 Page 3 of 4 Z 2026-001 Page 4 of 4 Z 2026-001 Revised 10.09.2023 1 City Hall – 125 N. Main Street, Suite 468 – Memphis, Tennessee 38103 – (901) 636-6619 LAND USE CONTROL BOARD REZONING APPLICATION TO FILE ONLINE USE THE DEVELOP 901 CITIZEN PORTAL Date: Prev ious Case/Docket #: PLEASE TYPE OR PRINT Property Owner of Record: Phon e #: Mailing Address: City/State: Zip: Property Owner Email Address: Applicant: Phone #: Mailing Address: City/State: Zip: Applicant Email Address: Representative: Phone #: Mailing Address: City/State: Zip: Representative Email Address: Architect/Engineer/Surveyor: Phone #: Mailing Address: City/State: Zip: Architect/Engineer/Surveyor Email Address: PREMISES LOCATION (Describe by street address & directional location description, e.g. 200 Johnson Street, North side of Johnson Street, 100 feet east of Brown Street): Parcel ID: Project Name: Project Description: Did you have a pre-application meeting with the Division of Planning and Development (DPD)? Planner: Date of Meeting: Revised 10.09.2023 2 Area A Area B Area C Acres: _______________ _______________ _______________ Existing Zoning: _______________ _______________ _______________ Existing Use of Property: _______________ _______________ _______________ Requested Use of Property: _______________ _______________ _______________ Requested Zoning: _______________ _______________ _______________ Is this application in response to a citation, stop work order, or zoning letter? (y es or no) If yes, please provide a copy of the citation, stop work order, and/or zoning letter along with any other relevant information: REVIEW CRITERIA (UDC Sub-Section 9.5.7B) In making recommendations, the Land Use Control Board shall consider the following matters: 1) Consistency with any plans to be considered (see Chapter 1.9): 2) Compatibility with the present zoning (including any residential corridor overlay district) and conforming uses of nearby property and with the character of the neighborhood: 3) Suitability of the subject property for uses permitted by the current versus the proposed district: 4) Whether the proposed change tends to improve the balance of uses, or meets a specific demand in the City or County: Revised 10.09.2023 3 5) The availability of adequate police services, fire services, school, road, park, wastewater treatment, water supply and stormwater drainage facilities for the proposed zoning: LAND USE CONTROL BOARD REZONING APPLICATION GUIDE To file online use the Develop 901 Citizen Portal: www.aca-prod.accela.com/SHELBYCO/Default GENERAL INFORMATION UNIFIED DEVELOPMENT CODE (UDC) REFERENCES FOR REZONINGS: a) Zoning Change – UDC Chapter 9.5 PRE-APPLICATION MEETING – This is a meeting in which the Division of Planning and Development Land Use and Development Services discusses the procedures, standards, and regulations required of a request in accordance with the Unified Development Code with the applicant(s) and/or their representative(s), see Section 9.3.1 of Unified Development Code for additional information. To schedule a pre-applicatio n meeting please call Land Use and Development Services at (901) 636-6619. APPL ICATION REVIEW PROCESS – Click here to view a flowchart that explains the review process by application type, as well as the expected review time for each. NEIG HBOORHOOD MEETING – At least ten (10) days, but not more than one hundred twenty (120) days, prior to a hearing before the Land Use Control Board, the applicant shall provide an opportunity to discuss the proposal with representatives from neighborhoods adjacent to the development site, see Section 9.3.2 of the Unified Development Code for additional information, procedures, standards, and requirements. APPL ICATION DEADLINES – A link to the Applications Deadlines Calendar can be found on the Land Use and Development Services’ webpage. APPLICATION ASSISTANCE – Click here to view a list of firms and individuals who frequently provide assistance with the filing of applications with the Division of Planning and Development. FILI NG FEE(S) – See the Fee Schedule. Make checks payable to “M/SC Division of Planning and Development” POSTED NOTICE – Posting sign(s) may be required ; refer to Sub-Sections 9.3.4A and 9.3.4C of the Unified Development Code for specific requirements. If posted notice is required, the sign affidavit and a photograph of each sign on the subject property are also mandatory. Download templates of the sign in a PowerPoint document. Click here for a list of companies that may be able to produce posted notice signs. ZONING CHANGE REQUIREMENTS A rezoning must meet the following requirements of Section 9.5.2 of the UDC: A. A zoning change shall correspond with the boundary lines of existing tracts and lots, and with the centerline of any abutting streets or alleys. Where the boundaries of a zoning change request stop short of an exterior property line, it must be possible to subdivide and develop that portion of the property outside the proposed zoning change boundary in accordance with the existing zoning and other requirements of this development code. B. All zoning requirements shall be met within the boundaries of the area being rezoned. If all of the requirements Revised 10.09.2023 4 cannot be met on the site being rezoned, the zoning change shall be expanded to include all property necessary to meet zoning requirements. C. Any zoning change affecting property within a community redevelopment area shall be supported by the Community Redevelopment Plan for that area. REQUIRED DOCUMENTS As part of the application, the following documents are required to be submitted: LETTER OF INTENT – A brief narrative statement generally describing the nature, location, and extent of the development and the market it is intended to serve. PLOT PLAN – In general, a drawing of the subject property drawn to an engineering scale, showing property boundary lines and dimensions, existing utilities and easements, roadways, rail lines and public rights-of-way, crossing and adjacent to the subject property; etc. LEGAL DESCRIPTION IN WORD – A land description legally sufficient in the matter of locatability that identifies a particular locatable area or areas to which the interest conveyed attaches . It should contain title identity, not interfere with the senior rights of others, be so written that either at the present or at a future date, a competent surveyor can readily locate it, not contain words capable of alternate interpretations, contain measurement data sufficient to describe a geometric area that closes mathematically, and be based on a recent survey. VICINITY MAP – Map showing the subject property (boldly outlined) and all adjacent parcel owners. Refer to Sub-Section 9.3.4A of the Unified Development Code for specific notification requirements. Public Notice Tool User Guide. MAILING LABELS OF NAMES AND ADDRESSES – A complete list of names and mailing addresses, of all property owners shown on the vici nity map, typewritten, and formatted as 1" x 2 5/8" labels (Avery 5160). Additionally, include the application property owner of record, applicant, representative, and/or Architect/Engineer/Surveyor. Public Notice Tool User Guide. DEED(S) – Most recent deed(s) on file with Shelby County Register of Deeds. OWNER AFFIDAVIT – Affidavit of ownership or owner designee. Additional documents may be required prior to approval. kimley-horn.com 6750 Poplar Avenue, Suite 600, Memphis, Tennessee 38138 901-374-9109 January 02, 2025 Mr. Jeffrey Penzes and Ms. Mahsan Ostadnia Land Use and Development Services Division of Planning and Development 125 N. Main, Ste. 468 Memphis, Tennessee 38103 RE: Rezoning Application - Chelsea Avenue Project Mr. Penzes and Ms. Ostadnia: On behalf of the Developer, Elmington Capital Group , we are pleased to submit the enclosed rezoning application. The thirteen subject parcels in this rezoning application total 3.30 acres and are located along Tully and Woodlawn Streets. Additionally, the subject parcels will be part of a total project area for a multi -family development (inclusive of the thirteen within this rezoning application) for a total of 4.39 acres and includes frontage along Chelsea Avenue. This rezoning application is requesting that the current M ixed-Use (MU) zoning designation located along Chelsea Avenue be expanded to include the subject parcels. In collaboration with Elmington Capital Group, the proposed total project area of 4.39 acres has been conceptually designed as an approximate ly 158-unit multi- family development. The conceptual plan consists of a mix of 2-, 3-, and 4-bedroom units, leasing office, resident amenity areas, and ancillary parking. The rezoning of the subject parcels will provide the necessary bulk regulations to support multi-family development while providing improved streetscapes, buildings that front adjacent streets, and concealed parking areas. Please find enclosed the required rezoning application documents, as well as additional support documents. We are confident that the Division of Planning and Development staff, Land Use Control Board members and City Council members will find that the rezoning application and proposed multi-family development rises to the City’s standards and will be a benefit to the community. Elmington Capital Group has successfully delivered quality development throughout Memphis including Tillman Cove, Uptown Flats, 2nd Street Flats, Burkle & Main, Forum Flats and Patterson Flats and intends to implement the same high level of quality with this proposed development. On behalf of the applicant, thank you for your assistance and consideration of this request; we look forward to working with you. If we can answer any questions or be of assistance, please do not hesitate to contact me. Sincerely, Kimley-Horn & Associates, Inc. Owen Harris, PLA, ASLA CHELSEA AVENUE TULLY STREET WOODLAWN STREET LARRY BLANDINST. BH 1636ZONED M-U INFINITY REALESTATE AND DEVELOPMENT LLC INST. 20090261 ZONED M-U MDM INVESTMENTS OFMEMPHIS LLC, ISAOA INST. 20103236 ZONED M-U -66- -67- -68- -69- -70- -71- -72- -73- -74- -65- -64- -63- -62- -61- -60- -59- -58- MDM INVESTMENTS OFMEMPHIS LLC, ISAOA INST. 20103236 ZONED M-U MDM INVESTMENTS OF MEMPHIS LLCINST. 21093104 ZONED M-U MDM INVESTMENTS OFMEMPHIS LLC, ISAOA INST. 20103237 ZONED M-U MDM INVESTMENTS OF MEMPHIS LLC, ISAOA INST. 20103237 ZONED M-U MDM INVESTMENTS OF MEMPHIS LLC, ISAOA INST. 20103237 ZONED M-U MDM INVESTMENTS OF MEMPHIS, LLC INST. 21093097 ZONED RU-1 MDM INVESTMENTS OF MEMPHIS, LLC INST. 21093098 ZONED RU-1 MDM INVESTMENTS OF MEMPHIS, LLC INST. 21093099 ZONED RU-1 MDM INVESTMENTS OF MEMPHIS, LLC INST. 22090622 ZONED RU-1 SOUTH CITY MEMPHIS LLC INST. 21027145 ZONED RU-1 MICHAEL MCGHEE INST. 22125049 ZONED RU-1 SNOWBALL 221 LP INST. 16068208 ZONED RU-1 -57- MDM INVESTMENTS OF MEMPHIS, LLC INST. 20122637 ZONED RU-1 -75- -76- -77- -78- -79- -80- MDM INVESTMENTS OF MEMPHIS LLC, ISAOA INST. 20103232 ZONED RU-1 MDM INVESTMENTS OF MEMPHIS LLC INST. 21016675 ZONED RU-1 TRINETTE JACKSON INST. 12034578 ZONED RU-1 MICHAEL MCGHEE INST. 23043339 ZONED RU-1 MDM INVESTMENTS OF MEMPHIS LLC, ISAOA INST. 20103229 ZONED RU-1 MDM INVESTMENTS OF MEMPHIS, LLC INST. 21016675 ZONED RU-1 L- 31.72 R- 15.00 D-121°09'32" CB- S 51°13'47" E CH- 26.13 E E E 80' RIGHT-OF-WAY PUBLIC 60' RIGHT-OF-WAY PUBLIC 60' RIGHT-OF-WAY PUBLIC 10.5 E EX. SIGN MICHAEL MCGHEE INST. 22019127 ZONED RU-1 S80°08'54"E 100.00'S80°08'54"E 99.82' N9°20'59"E 100.16' S80°18'58"E 100.00' N9°20'59"E 36.20' S80°18'58"E 100.00' S9°20'59"W 436.94' N80°08'55"W 400.04' N9°23'26"E 300.00' AREA OF REZONING 3.30 ACRES 143,686.31 S.F. 0 December 22, 2025 NORTH 20 40 80 120 CHELSEA AVENUE PROJECT PLOT PLAN PLOT PLAN LEGEND AREA OF REZONING BOUNDARY ADJACENT PARCEL LINES PARCEL LINES WITHIN AREA OF REZONING PROJECT AREA CHELSEA AVENUECHELSEA AVENUE CHELSEA Chelsea Avenue at Tully Street Municipality: Memphis Tennessee PRELIMINARY YIELD STUDY CONCEPT B 0’0’ 15’15’ 30’30’ SCALE: 1”=30’SCALE: 1”=30’ 60’60’ N BUILDING 1 4 Story Corridor +/- 54 Units BUILDING 2 4 Story Corridor +/- 64 Units BUILDING 3 4 Story Corridor +/- 40 Units STREET PARKINGSTREET PARKING CLUBHOUSE/LEASING TRASH COLLECTION STORM UNDERGROUND DEVELOPMENT SUMMARY 4.0 Acres 158 Multi-Family Units +/- 39.5 units/acre Parking Provided: 193 Surface Spaces 26 Str eet Spaces 1.39 per unit This plan depicts a preliminary layout for site zoning purposes. Final layout may vary to accommodate site conditions. PROPOSED UNIT MIX TOTAL: 158 2 Bedroom: 36 3 Bedroom: 90 4 Bedroom: 32 TULLY STREETTULLY STREET WOODLAWN STREETWOODLAWN STREET CHELSEA AVENUE PROJECT MEMPHIS, TENNESSEE CONCEPT DESIGN 4.39 Acres 158 Multi-Family Units Example Architecture 12/30/2025 Chelsea Avenue Page 2 kimley-horn.com 6750 Poplar Avenue, Suite 600, Memphis, TN 38138 901 374 9109 Figure 1: Vicinity Map Site North CHELSEA AVENUE TULLY STREET WOODLAWN STREET LARRY BLANDINST. BH 1636ZONED M-U INFINITY REALESTATE AND DEVELOPMENT LLC INST. 20090261 ZONED M-U MDM INVESTMENTS OFMEMPHIS LLC, ISAOA INST. 20103236 ZONED M-U -66- -67- -68- -69- -70- -71- -72- -73- -74- -65- -64- -63- -62- -61- -60- -59- -58- MDM INVESTMENTS OFMEMPHIS LLC, ISAOA INST. 20103236 ZONED M-U MDM INVESTMENTS OF MEMPHIS LLCINST. 21093104 ZONED M-U MDM INVESTMENTS OFMEMPHIS LLC, ISAOA INST. 20103237 ZONED M-U MDM INVESTMENTS OF MEMPHIS LLC, ISAOA INST. 20103237 ZONED M-U MDM INVESTMENTS OF MEMPHIS LLC, ISAOA INST. 20103237 ZONED M-U MDM INVESTMENTS OF MEMPHIS, LLC INST. 21093097 ZONED RU-1 MDM INVESTMENTS OF MEMPHIS, LLC INST. 21093098 ZONED RU-1 MDM INVESTMENTS OF MEMPHIS, LLC INST. 21093099 ZONED RU-1 MDM INVESTMENTS OF MEMPHIS, LLC INST. 22090622 ZONED RU-1 SOUTH CITY MEMPHIS LLC INST. 21027145 ZONED RU-1 MICHAEL MCGHEE INST. 22125049 ZONED RU-1 SNOWBALL 221 LP INST. 16068208 ZONED RU-1 -57- MDM INVESTMENTS OF MEMPHIS, LLC INST. 20122637 ZONED RU-1 -75- -76- -77- -78- -79- -80- MDM INVESTMENTS OF MEMPHIS LLC, ISAOA INST. 20103232 ZONED RU-1 MDM INVESTMENTS OF MEMPHIS LLC INST. 21016675 ZONED RU-1 TRINETTE JACKSON INST. 12034578 ZONED RU-1 MICHAEL MCGHEE INST. 23043339 ZONED RU-1 MDM INVESTMENTS OF MEMPHIS LLC, ISAOA INST. 20103229 ZONED RU-1 MDM INVESTMENTS OF MEMPHIS, LLC INST. 21016675 ZONED RU-1 L- 31.72 R- 15.00 D-121°09'32" CB- S 51°13'47" E CH- 26.13 E E E 80' RIGHT-OF-WAY PUBLIC 60' RIGHT-OF-WAY PUBLIC 60' RIGHT-OF-WAY PUBLIC 10.5 E EX. SIGN MICHAEL MCGHEE INST. 22019127 ZONED RU-1 S80°08'54"E 100.00'S80°08'54"E 99.82' N9°20'59"E 100.16' S80°18'58"E 100.00' N9°20'59"E 36.20' S80°18'58"E 100.00' S9°20'59"W 436.94' N80°08'55"W 400.04' N9°23'26"E 300.00' AREA OF REZONING 3.30 ACRES 143,686.31 S.F. PLOT PLAN LEGEND AREA OF REZONING BOUNDARY ADJACENT PARCEL LINES PARCEL LINES WITHIN AREA OF REZONING PROJECT AREA NORTH Page 3 kimley-horn.com 6750 Poplar Avenue, Suite 600, Memphis, TN 38138 901 374 9109 Figure 2: Preliminary Site Plan Page 4 kimley-horn.com 6750 Poplar Avenue, Suite 600, Memphis, TN 38138 901 374 9109 TRIP GENERATION Land Use Category 221 Multifamily Housing (Mid-Rise) was used to estimate the number of trips generated as a part of the proposed development for the proposed multifamily housing (mid-rise) land use. Traffic generated by the proposed development will access the site via one full-access driveway along Tully Street and one full-access driveway along Woodlawn Street. Based on the site layout and location of the proposed access points, it is assumed that approximately 50% of trips generated by the site will enter/exit via Tully Street and 50% will enter/exit via Woodlawn Street. All trips generated by the proposed development are expected to enter/exit the site via Chelsea Avenue. A summary of the estimated trip generation for the proposed development can be found in Table 1. Table 1: Trip Generation Summary Table ADJACENT ROAD INFORMATION The subject development has frontage along Chelsea Avenue but does not provide access along Chelsea Avenue. Based on TDOT historical traffic data, Chelsea Avenue had an AADT of approximately 5,807 vehicles in 2025. The TDOT traffic data for Chelsea Avenue is provided in Figure 3. (Intentionally Left Blank) Daily Trips Total Total In Out Total In Out 221 Multifamily Housing (Mid-Rise) 158 D.U. 705 59 14 45 60 38 22 705 59 14 45 60 38 22 PM Peak Hour TripsITE Code Land Use Type Intensity AM Peak Hour Trips Trip Generation Table Total Proposed External Site Trips Page 5 kimley-horn.com 6750 Poplar Avenue, Suite 600, Memphis, TN 38138 901 374 9109 Figure 3: Chelsea Avenue TDOT Traffic History Page 6 kimley-horn.com 6750 Poplar Avenue, Suite 600, Memphis, TN 38138 901 374 9109 EVALUATION The first, second, third, fourth, and fifth criteria included in the City of Memphis Engineering Design Review and Policy Manual for determining if a traffic impact study is required are not applicable. The development will not generate 500 or more peak hour trips. Chelsea Avenue is classified by TDOT as an Urban Minor Arterial, but the AADT is less than 15,000 and the development will not generate 150 or more peak hour trips along Chelsea Avenue. Tully Street is not currently classified by TDOT, but the development will not generate 100 or more peak hour trips along Tully Street. Woodlawn Street is not currently classified by TDOT, but the development will not generate 100 or more peak hour trips along Woodlawn Street. The sixth criterion, which is applicable to this project, is as follows: 6. Any development that would generate peak hour trips equivalent to 1% of the adjacent roadway AADT, or average weekday trips equivalent to 10% of the adjacent roadway AADT. This criterion was evaluated using the TDOT count station on Chelsea Avenue east of the proposed development. The results of the analysis are summarized below: 6. Based on TDOT historical traffic count data, Chelsea Avenue had an AADT of approximately 5,807 vehicles per day in 2025. Table 2 provides the results of the evaluation using these criteria. Table 2: ECG Chelsea Trip Generation Analysis Based on the results as described above and summarized in Table 2, the hourly and daily trips produced by this development along Chelsea Avenue exceed the City of Memphis minimum criteria for determining if a traffic study is required. Chelsea Avenue 2025 AADT Peak Hour Trips % of AADT Greater than 1% AADT? Average Weekday Trips % of AADT Greater than 10% AADT? TDOT Traffic History Count 5,807 60 1.0% YES 705 12% YES kimley-horn.com 6750 Poplar Avenue, Suite 600, Memphis, Tennessee 38138 901-374-9109 January 02, 2026 Mr. Jeffrey Penzes Ms. Mahsan Ostadnia City of Memphis Division of Planning and Development 125 N. Main, Ste. 468 Memphis, Tennessee 38103 RE: Rezoning Application Chelsea Avenue Project Legal Description - Boundary of Parcels to be Rezoned BEGINNING AT A POINT IN THE WEST LINE OF WOODLAWN STREET (60 FEET RIGHT OF WAY), 85.11 FEET NORTH OF THE NORTH LINE OF CHELSEA AVENUE (80 FEET RIGHT OF WAY), BEING IN THE NORTH LINE OF THE LARRY BLAND PROPERTY AS DESCRIBED IN INSTRUMENT BH 1636, BEING THE NORTH LINE OF LOT 73, SNOWDEN AND BRINKLEY SUBDIVISION AS RECORDED IN PLAT BOOK 3 PAGE 38; THENCE NORTH 09 DEGREES 23 MINUTES 26 SECONDS EAST ALONG THE WEST LINE OF WOODLAWN STREET A DISTANCE OF 300.00 FEET TO THE SOUTH LINE OF THE MDM INVESTMENTS, LLC PROPERTY AS DESCRIBED IN INSTRUMENT 21016675 AND BEING THE SOUTH LINE OF LOT 80, SNOWDEN AND BRINKLEY SUBDIVISION; THENCE NORTH 80 DEGREES 08 MINUTES 55 SECONDS WEST ALONG THE NORTH LINE OF LOT 79 AND LOT 58, SNOWDEN AND BRINKLEY SUBDIVISION, A DISTANCE OF 400.04 FEET; THENCE SOUTH 09 DEGREES 20 MINUTES 59 SECONDS WEST ALONG THE EAST LINE OF TULLY STREET A DISTANCE OF 436.94 FEET TO THE NORTH LINE OF THE MDM INVESTMENTS, LLC PROPERTY AS DESCRIBED IN INSTRUMENT 20103237; THENCE SOUTH 80 DEGREES 18 MINUTES 58 SE CONDS EAST A DISTANCE OF 100.00 FEET ; THENCE NORTH 09 DEGREES 20 MINUTES 59 SECONDS EAST A DISTANCE OF 36.20 FEET; THENCE SOUTH 80 DEGREES 18 MINUTES 58 SECONDS EAST ALONG THE NORTH LINE OF LOT 68 AND LOT 69, SNOWDEN AND BRINKLEY SUBDIVISION, A DISTANCE OF 100.00 FEET; THENCE NORTH 09 DEGREES 20 MINUTES 59 SECONDS EAST ALONG THE WEST LINE OF LOT 70, SNOWDEN AND BRINKLEY SUBDIVISION , A DISTANCE OF 100.16 FEET; THENCE SOUTH 80 DEGREES 08 MINUTES 54 SECONDS EAST ALONG THE NORTH LINE OF LOT 70 AND LOT 71, SNOWDEN AND BRINKLEY SUBDIVISION , A DISTANCE OF 99.82; THENCE SOUTH 80 DEGREES 08 MINUTES 54 SECONDS EAST ALONG THE NORTH LINE OF LOT 72 AND LOT 73, SNOWDEN AND BRINKLEY SUBDIVISION, A DISTANCE OF 100.00 FEET TO THE POINT OF BEGINNING, CONTAINING 143,686.31 SQUARE FEET / 3.30 ACRES MORE OR LESS. Legend polygonLayer Override 1 Override 2 polygonLayer Override 1 Roads Parcels 0 0.06 0.12 0.18 0.24 mi Map prepared through Shelby County Government's online mapping Portal on 12/29/2025 ¯

Source: City of Memphis website. First collected Oct 27, 2026.