Regular Meeting Planning and Zoning Documents
City of Memphis · Shelby County · meeting of Dec 16, 2025 · Agendas
Open the original document More from City of Memphis
This document is no longer listed on City of Memphis's website. We kept the copy we read.
Text
Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.
Memphis City Council
Summary Sheet
PD 2025-002
RESOLUTION PURSUANT TO CHAPTER 9.6 OF THE MEMPHIS AND SHELBY COUNTY UNIFIE D
DEVELOPMENT CODE APPROVING A PLANNED D EVELOPMENT AT THE SUBJECT PROPERTY
LOCATED AT 3021 EAST SHELBY DRIVE, KNOWN AS CASE NUMBER PD 2025-002
• This item is a resolution with conditions to allow an amendment to PD 06-349 to
add additional land for storage; and
• This resolution, if approved with conditions, will supersede the existing zoning for
this property; and
• The item may require future public improvement contracts.
1
LAND USE CONTROL BOARD RECOMMENDATION
At its regular meeting on Thursday, July 10, 2025, the Memphis and Shelby County Land Use Control Board
held a public hearing on the following application:
CASE NUMBER: PD 2025-002
DEVELOPMENT: Shelby Rail Service Planned Development
LOCATION: 3021 East Shelby Drive
COUNCIL DISTRICT: District 3 and Super District 8 – Positions 1, 2, and 3
OWNER/APPLICANT: Shelby Railroad Service, Inc.
REPRESENTATIVE: Cindy Reaves, SR Consulting, LLC
REQUEST: Amendment to PD 06-349 to add additional land for storage
EXISTING ZONING: Residential Single Family – 8 (R-8)
AREA: +/-35.164 acres
The following spoke in support: Cindy Reaves, Dedrick Brittenum
The following spoke in opposition: None
The Land Use Control Board reviewed the application and the staff report . A motion was made and
seconded to recommend rejection.
The motion failed by a vote of 1-7-0 on the regular public hearing agenda.
Respectfully,
Alexis Longstreet
Alexis Longstreet
Planner
Land Use and Development Services
Division of Planning and Development
Cc: Committee Members
File
2
PD 2025-002
CONDITIONS
Outline Plan Conditions
I. USES PERMITTED:
A. Area A: Construction contractor with outdoor storage facility.
B. Area B: Vehicle and Equipment Outdoor Storage under lease such as Boats, Buses, Campers,
Contractor Equipment, Recreational Vehicles, Trucks, and other Vehicle Storage uses.
C. Area C: Uses permitted by right in the CMU -2 District
D. In Areas A and B, uses permitted by right in the EMP district, except that the following uses
shall be prohibited:
1. Adult entertainment (excluded)
2. Off-Premise Advertising Signs
3. Amusements, Commercial outdoor
4. Campground, Travel Trailer park
5. Drive-in Theater
6. Garage, Commercial
7. Tavern, cocktail lounge, nightclub
8. Brewery
9. Bus terminal or Service Facility
10. Taxicab Dispatch Station
11. Garage or Refuse Collection Service
12. Used Goods, Secondhand Sales
13. Chemical Manufacturing
14. Slaughtering Business
15. Beverage Recycling Center
16. Tractor-Trailer or Container storage, drop lot
II. BULK REGULATIONS:
A. The minimum front yard setback shall be 50 feet.
B. The minimum side yard setbacks shall be 10 feet.
C. The maximum height of any outdoor storage shall be 15 feet.
III. ACCESS, PARKING AND CIRCULATION:
A. Two curb cuts are permitted onto Shelby Drive.
B. The City Engineer shall approve the design, number and location of curb cuts. Any existing
nonconforming curb cuts shall be modified to meet current City Standards or closed with
curb, gutter, and sidewalk.
C. No curb cut shall be located closer than 500 feet from the centerline of Swinnea Road.
D. The parking requirements of the EMP District shall apply.
E. All parking areas and driving aisles to be paved with asphalt or concrete.
F. Adequate queuing spaces in accordance with the current ordinance shall be provided
between the street right-of-way line and any proposed gate/guardhouse/card reader.
G. Adequate maneuvering room shall be provided between the right-of-way and the
gate/guardhouse/card reader for vehicles to exit by forward motion.
3
IV. SIGNS:
A. One ground -mounted monument style sign is permitted with a maximum area of 100
feet, to be designed and located with due consideration for sight distance requirements.
The final plan shall indicate the location and dimensions of any freestanding on -premise
sign, subject to the review and approval of the Division of Planning and Development.
A. Any additional signs shall be in accordance with the CMU-2 District.
B. No permanent off-premise advertising signs are permitted.
C. No temporary or portable signs are permitted.
D. All signs shall be set back a minimum of 10 feet from the right-of-way.
V. LANDSCAPING AND DESIGN:
A. The landscaping screen along Shelby Drive shall be as shown on the proposed site plan ,
shall be installed along the entire frontage and shall include an irrigation system for the
area.
B. The front elevation of the principal building shall be brick or masonry, and a graphic
rendering of that building shall be part of the final plan.
C. Outdoor lighting should be directed so that it does not glare onto nearby properties.
D. The existing trees along Shelby Drive for the amendment area shall be shown on the final Plat.
VI. DRAINAGE:
A. Drainage improvements, including on -site detention, shall be provided under a Standard
Subdivision contract in accordance with Subdivision Regulations and the City of Memphis
Drainage Design Manual.
B. Drainage data for assessment of on-site detention requirements shall be submitted to and
approved by the City Engineer.
VII. SITE PLAN REVIEW:
E. A site plan shall be submitted for the review, comment and recommendation of the Division
Office of Planning and Development and appropriate City and County agencies . for
approval of the Land Use Control Board prior to approval of any final plan for
development that includes acquisition of adjacent land to the west.
VIII. FINAL PLAN:
A. A final plan shall be recorded within 5 years from the date of the recording of the outline
plan, provided that the Land Use Control Board may approve an extension of this deadline.
B. Any final plan shall include the following:
1. The outline plan conditions,
2. A standard subdivision contract as defined by the Subdivision Regulations for any
needed public improvements.
3. The location and ownership, whether public or private, of any easement, and
4. The exact locations and dimensions including height of buildings, parking areas,
utility easements, drives, trash receptacles, loading facilities and required
4
landscaping and screening areas;
5. The content of all landscaping and screening is to be provided,
6. If applicable, a statement conveying facilities and areas to a property owners'
association or other entity for ownership and maintenance purposes,
7. The following note shall be placed on the f inal plat of any development requiring
on- site storm water facilities: The areas denoted by "Reserved for Storm Water
Detention" shall not be used as a building site or filled without first obtaining
written permission from the City Engineer. The storm water detention systems
located in these areas, except for those parts located in a public drainage
easement shall be owned and maintained by the property owner and/or
property owner's association. Such maintenance shall be performed so as to
ensure that the system operates in accordance with the approved plan on file in
the City Engineer's Office. Such maintenance shall include, but not be limited
to removal of sedimentation; fallen objects; debris; trash; mowing; outlet cleaning;
and repair of drainage structures.
5
CONCEPT PLAN
RESOLUTION PURSUANT TO CHAPTER 9.6 OF THE MEMPHIS AND SHELBY COUNTY
UNIFIED DEVELOPMENT C ODE APPROVING A PLANNED DEVELOPMENT AT T HE
SUBJECT PROPERTY LOCATED AT 3021 EAST SHELBY DRIVE , KNOWN AS CASE
NUMBER PD 2025-002
WHEREAS, Chapter 9.6 of the Memphis and Shelby County Unified Development Code, being a
section of the Joint Ordinance Resolution No. 5367, dated August 10, 2010, authorizes the Council of the
City of Memphis to grant a planned development for certain stated purposes in the various zoning districts;
and
WHEREAS, the Shelby Railroad Service, Inc. filed an application with the Memphis and Shelby
County Division of Planning and Development to allow an amendment to PD 06-349 to add additional land
for storage; and
WHEREAS, the Division of Planning and Development has received and reviewed the application
in accordance with procedures, objectives and standards for planned developments as set forth in Chapter
9.6 with regard to the proposed development's impacts upon surrounding propertie s, availability of public
facilities, both external and internal circulation, land use compatibility, and that the design and amenities
are consistent with the public interest; and has submitted its findings and recommendation subject to outline
plan conditions concerning the above considerations to the Memphis and Shelby County Land Use Control
Board; and
WHEREAS, a public hearing in relation thereto was held before the Memphis and Shelby County
Land Use Control Board on July 10, 2025, and said Board has submitted its findings and recommendation
subject to outline plan conditions concerning the above considerations to the Council of the City of
Memphis; and
WHEREAS, the Council of the City of Memphis has reviewed the aforementioned application
pursuant to Tennessee Code Annotated Section 13 -4-202(B)(2)(B)(iii) and has determined that said
development is consistent with the Memphis 3.0 General Plan; and
WHEREAS, the Council of the City of Memphis has reviewed the recommendation of the Land
Use Control Board and the report and recommendation of the Division of Planning and Development and
has determined that said development meets the objectives, standards and criteria for a special use permit,
and said development is consistent with the public interests.
NOW, THEREFORE, BE IT RESOLVED, BY THE COUNCIL OF THE CITY OF
MEMPHIS, that, pursuant to Chapter 9.6 of the Memphis and Shelby County Unified Development Code,
a planned development is hereby granted in accordance with the attached outline plan conditions.
BE IT FURTHER RESOLVED , that the requirements of said aforementioned clause of the
Unified Development Code shall be deemed to have been complied with; that the outline plan shall bind
the applicant, owner, mortgagee, if any, and the legislative body with respect to the contents of said plan;
and the applicant and/or owner may file a final plan in accordance with said outline plan and the provisions
of Section 9.6.11 of the Unified Development Code.
OUTLINE PLAN CONDITIONS
Outline Plan Conditions
I. USES PERMITTED:
A. Area A: Construction contractor with outdoor storage facility.
B. Area B: Vehicle and Equipment Outdoor Storage under lease such as Boats, Buses, Campers,
Contractor Equipment, Recreational Vehicles, Trucks, and other Vehicle Storage uses.
C. Area C: Uses permitted by right in the CMU -2 District
D. In Areas A and B, uses permitted by right in the EMP district, except that the following uses
shall be prohibited:
1. Adult entertainment (excluded)
2. Off-Premise Advertising Signs
3. Amusements, Commercial outdoor
4. Campground, Travel Trailer park
5. Drive-in Theater
6. Garage, Commercial
7. Tavern, cocktail lounge, nightclub
8. Brewery
9. Bus terminal or Service Facility
10. Taxicab Dispatch Station
11. Garage or Refuse Collection Service
12. Used Goods, Secondhand Sales
13. Chemical Manufacturing
14. Slaughtering Business
15. Beverage Recycling Center
16. Tractor-Trailer or Container storage, drop lot
II. BULK REGULATIONS:
A. The minimum front yard setback shall be 50 feet.
B. The minimum side yard setbacks shall be 10 feet.
C. The maximum height of any outdoor storage shall be 15 feet.
III. ACCESS, PARKING AND CIRCULATION:
A. Two curb cuts are permitted onto Shelby Drive.
B. The City Engineer shall approve the design, number and location of curb cuts. Any existing
nonconforming curb cuts shall be modified to meet current City Standards or closed with
curb, gutter, and sidewalk.
C. No curb cut shall be located closer than 500 feet from the centerline of Swinnea Road.
D. The parking requirements of the EMP District shall apply.
E. All parking areas and driving aisles to be paved with asphalt or concrete.
F. Adequate queuing spaces in accordance with the current ordinance shall be provided
between the street right-of-way line and any proposed gate/guardhouse/card reader.
G. Adequate maneuvering room shall be provided between the right-of-way and the
gate/guardhouse/card reader for vehicles to exit by forward motion.
IV. SIGNS:
A. One ground -mounted monument style sign is permitted with a maximum area of 100
feet, to be designed and located with due consideration for sight distance requirements.
The final plan shall indicate the location and dimensions of any freestanding on -premise
sign, subject to the review and approval of the Division of Planning and Development.
A. Any additional signs shall be in accordance with the CMU-2 District.
B. No permanent off-premise advertising signs are permitted.
C. No temporary or portable signs are permitted.
D. All signs shall be set back a minimum of 10 feet from the right-of-way.
V. LANDSCAPING AND DESIGN:
A. The landscaping screen along Shelby Drive shall be as shown on the proposed site plan ,
shall be installed along the entire frontage and shall include an irrigation system for the
area.
B. The front elevation of the principal building shall be brick or masonry, and a graphic
rendering of that building shall be part of the final plan.
C. Outdoor lighting should be directed so that it does not glare onto nearby properties.
D. The existing trees along Shelby Drive for the amendment area shall be shown on the final Plat.
VI. DRAINAGE:
A. Drainage improvements, including on -site detention, shall be provided under a Standard
Subdivision contract in accordance with Subdivision Regulations and the City of Memphis
Drainage Design Manual.
B. Drainage data for assessment of on-site detention requirements shall be submitted to and
approved by the City Engineer.
VII. SITE PLAN REVIEW:
E. A site plan shall be submitted for the review, comment and recommendation of the Division
Office of Planning and Development and appropriate City and County agencies . for
approval of the Land Use Control Board prior to approval of any final plan for
development that includes acquisition of adjacent land to the west.
VIII. FINAL PLAN:
A. A final plan shall be recorded within 5 years from the date of the recording of the outline
plan, provided that the Land Use Control Board may approve an extension of this deadline.
B. Any final plan shall include the following:
1. The outline plan conditions,
2. A standard subdivision contract as defined by the Subdivision Regulations for any
needed public improvements.
3. The location and ownership, whether public or private, of any easement, and
4. The exact locations and dimensions including height of buildings, parking areas,
utility easements, drives, trash receptacles, loading facilities and required
landscaping and screening areas;
5. The content of all landscaping and screening is to be provided,
6. If applicable, a statement conveying facilities and areas to a property owners'
association or other entity for ownership and maintenance purposes,
7. The following note shall be placed on the f inal plat of any development requiring
on- site storm water facilities: The areas denoted by "Reserved for Storm Water
Detention" shall not be used as a building site or filled without first obtaining
written permission from the City Engineer. The storm water detention systems
located in these areas, except for those parts located in a public drainage
easement shall be owned and maintained by the property owner and/or
property owner's association. Such maintenance shall be performed so as to
ensure that the system operates in accordance with the approved plan on file in
the City Engineer's Office. Such maintenance shall include, but not be limited
to removal of sedimentation; fallen objects; debris; trash; mowing; outlet cleaning;
and repair of drainage structures.
CONCEPT PLAN
ATTEST:
CC: Division of Planning and Development
– Land Use and Development Services
– Office of Construction Enforcement
Staff Writer: Alexis Longstreet E-mail: alexis.longstreet@memphistn.gov
AGENDA ITEM: 1 L.U.C.B. MEETING: July 10, 2025
CASE NUMBER: PD 2025-002
DEVELOPMENT: Shelby Rail Service Planned Development
LOCATION: 3021 East Shelby Drive
COUNCIL DISTRICT: District 3 and Super District 8 – Positions 1, 2, and 3
OWNER/APPLICANT: Shelby Railroad Service, Inc.
REPRESENTATIVE: Cindy Reaves, SR Consulting, LLC
REQUEST: Amendment to PD 06-349 to add additional land for storage
EXISTING ZONING: Residential Single Family – 8 (R-8)
CONCLUSIONS
1. The subject property is located +/-1,320 feet from the Jackson Pitt Dump.
2. The applicant is proposing to utilize the additional land for “construction contractor with outdoor storage
facility”. There aren’t any proposed structures other storage containers that serve as stalls on the additional
land to be added.
3. The proposed additional land has been excavated and replaced with gravel landscaping. See pages 9 – 12
for photos of the current conditions of the subject property.
4. The proposed uses permitted, as noted in the outline plan conditions, are that in which are permitted in
the Employment (EMP) zoning district.
5. The project will have a substantial or undue adverse effect upon adjacent property, the character of the
neighborhood, traffic conditions, parking, utility facilities and other matters affecting the public health,
safety, and general welfare.
CONSISTENCY WITH MEMPHIS 3.0
This proposal is inconsistent with the Memphis 3.0 General Plan per the land use decision criteria. See further
analysis on pages 26 – 28 of this report.
RECOMMENDATION:
Rejection
Staff Report July 10, 2025
PD 2025-002 Page 2
2
LOCATION MAP
Subject property located within the pink circle
SUBJECT PROPERTY
Staff Report July 10, 2025
PD 2025-002 Page 3
3
PUBLIC NOTICE VICINITY MAP
Subject property highlighted in yellow
PUBLIC NOTICE DETAILS
In accordance with Sub-Section 9.3.4A of the Unified Development Code, a notice of public hearing is required
to be mailed and signage posted. A total of 22 notices were mailed on March 21, 2025, see page 28 of this report
for a copy of said notice. Additionally, one sign was posted at the subject property, see page 29 of this report
for a copy of the sign affidavit.
NEIGHBORHOOD MEETING
The meeting was held at 5: 30 PM on Monday, March 31, 2025 , at Shelby Railroad Services, 3021 East Shelby
Drive.
Staff Report July 10, 2025
PD 2025-002 Page 4
4
AERIAL
Subject property outlined in yellow
Staff Report July 10, 2025
PD 2025-002 Page 5
5
ZONING MAP
Subject property highlighted in yellow
Staff Report July 10, 2025
PD 2025-002 Page 6
6
LAND USE MAP
Subject property indicated by a pink star
Staff Report July 10, 2025
PD 2025-002 Page 7
7
SITE PHOTOS
View of subject property looking north.
Staff Report July 10, 2025
PD 2025-002 Page 8
8
View of subject property looking south.
Staff Report July 10, 2025
PD 2025-002 Page 9
9
CURRENT CONDITION OF SUBJECT PROPERTY
Staff Report July 10, 2025
PD 2025-002 Page 10
10
Staff Report July 10, 2025
PD 2025-002 Page 11
11
Staff Report July 10, 2025
PD 2025-002 Page 12
12
Staff Report July 10, 2025
PD 2025-002 Page 13
13
CONCEPT PLAN
Staff Report July 10, 2025
PD 2025-002 Page 14
14
CONCEPT PLAN – MAGNIFIED
Staff Report July 10, 2025
PD 2025-002 Page 15
15
LANDSCAPE PLAN
Staff Report July 10, 2025
PD 2025-002 Page 16
16
CONCEPT PLAN – STAFF DESIGNED
Staff Report July 10, 2025
PD 2025-002 Page 17
17
CASE REVIEW
Request
The request is an amendment to PD 06-349 to add additional land for storage.
Applicability
Staff disagrees the applicability standards and criteria as set out in Section 4.10.2 of the Unified Development
Code are or will be met.
4.10.2 Applicability
The governing bodies may, upon proper application, grant a special use permit for a planned development (see
Chapter 9.6) for a tract of any size within the City or for tracts of at least three acres in unincorporated Shelby
County to facilitate the use of flexible techniques of land development and site design, by providing relief from
district requirements designed for conventional developments, and may establish standards and procedures for
planned developments in order to obtain one or more of the following objectives:
A. Environmental design in the development of land that is of a higher quality than is possible under the
regulations otherwise applicable to the property.
B. Diversification in the uses permitted and variation in the relationship of uses, structures, open space and
height of structures in developments intended as cohesive, unified projects.
C. Functional and beneficial uses of open space areas.
D. Preservation of natural features of a development site.
E. Creation of a safe and desirable living environment for residential areas characterized by a unified
building and site development program.
F. Rational and economic development in relation to public services.
G. Efficient and effective traffic circulation, both within and adjacent to the development site, that supports
or enhances the approved transportation network.
H. Creation of a variety of housing compatible with surrounding neighborhoods to provide a greater choice
of types of environment and living units.
I. Revitalization of established commercial centers of integrated design to order to encourage the
rehabilitation of such centers in order to meet current market preferences.
J. Provision in attractive and appropriate locations for business and manufacturing uses in well -designed
buildings and provision of opportunities for employment closer to residence with a reduction in travel
time from home to work.
K. Consistency with the Memphis 3.0 General Plan.
General Provisions
Staff disagrees the general provisions standards and criteria as set out in Section 4.10.3 of the Unified
Development Code are or will be met.
4.10.3 General Provisions
The governing bodies may grant a special use permit for a planned development which modifies the applicable
district regulations and other regulations of this development code upon written findings and recommendations
of the Land Use Control Board and the Zoning Administrator which shall be forwarded pursuant to provisions
contained in this Chapter.
A. The proposed development will not unduly injure or damage the use, value and enjoyment of surrounding
property nor unduly hinder or prevent the development of surrounding property in accordance with the
Staff Report July 10, 2025
PD 2025-002 Page 18
18
current development policies and plans of the City and County.
B. An approved water supply, community waste water treatment and disposal, and storm water drainage
facilities that are adequate to serve the proposed development have been or will be provided concurrent
with the development.
C. The location and arrangement of the structures, parking areas, walks, lighting and other service facilities
shall be compatible with the surrounding land uses, and any part of the proposed development not used
for structures, parking and loading areas or access way shall be landscaped or otherwise improved except
where natural features are such as to justify preservation.
D. Any modification of the district standards that would otherwise be applicable to the site are warranted
by the design of the outline plan and the amenities incorporated therein, and are not inconsistent with
the public interest.
E. Homeowners’ associations or some other responsible party shall be required to maintain any and all
common open space and/or common elements.
F. Lots of record are created with the recording of a planned development final plan.
Commercial or Industrial Criteria
Staff disagrees the additional planned commercial or industrial development criteria as set out in Section 4.10.5
of the Unified Development Code are or will be met.
4.10.5 Planned Commercial or Industrial Developments
Approval of a planned commercial or industrial development may be issued by the governing bodies for buildings
or premises to be used for the retail sale of merchandise and services, parking areas, office buildings, hotels and
motels and similar facilities ordinarily accepted as commercial center uses and those industrial uses which can
be reasonably be expected to function in a compatib le manner with the other permitted uses in the area. In
addition to the applicable standards and criteria set forth in Section 4.10.3, planned commercial or industrial
developments shall comply with the following standards:
A. Screening
When commercial or industrial structures or uses in a planned commercial or industrial development
abut a residential district or permitted residential buildings in the same development, screening may
be required by the governing bodies.
B. Display of Merchandise
All business, manufacturing and processing shall be conducted, and all merchandise and materials
shall be displayed and stored, within a completely enclosed building or within an open area which is
completely screened from the view of adjacent properties a nd public rights -of-way, provided,
however, that when an automobile service station or gasoline sales are permitted in a planned
commercial development, gasoline may be sold from pumps outside of a structure.
C. Accessibility
The site shall be accessible from the proposed street network in the vicinity which will be adequate to
carry the anticipated traffic of the proposed development. The streets and driveways on the site of
the proposed development shall be adequate to serve the enterprises located in the proposed
development.
D. Landscaping
Landscaping shall be required to provide screening of objectionable views of uses and the reduction
of noise. High-rise buildings shall be located within the development in such a way as to minimize any
adverse impact on adjoining low-rise buildings.
Staff Report July 10, 2025
PD 2025-002 Page 19
19
Approval Criteria
Staff disagrees the approval criteria as set out in Section 9.6.9 of the Unified Development Code are being met.
9.6.9 Approval Criteria
No special use permit or planned development shall be approved unless the following findings are made
concerning the application:
A. The project will not have a substantial or undue adverse effect upon adjacent property, the character of
the neighborhood, traffic conditions, parking, utility facilities and other matters affecting the public
health, safety, and general welfare.
B. The project will be constructed, arranged and operated so as to be compatible with the immediate vicinity
and not interfere with the development and use of adjacent property in accordance with the applicable
district regulations.
C. The project will be served adequately by essential public facilities and services such as streets, parking,
drainage, refuse disposal, fire protection and emergency services, water and sewers; or that the applicant
will provide adequately for such services.
D. The project will not result in the destruction, loss or damage of any feature determined by the governing
bodies to be of significant natural, scenic or historic importance.
E. The project complies with all additional standards imposed on it by any particular provisions authorizing
such use.
F. The request will not adversely affect any plans to be considered (see Chapter 1.9), or violate the character
of existing standards for development of the adjacent properties.
G. The governing bodies may impose conditions to minimize adverse effects on the neighborhood or on
public facilities, and to ensure compatibility of the proposed development with surrounding properties,
uses, and the purpose and intent of this development code.
H. Any decision to deny a special use permit request to place, construct, or modify personal wireless service
facilities shall be in writing and supported by substantial evidence contained in a written record, per the
Telecommunications Act of 1996, 47 USC 332(c)(7)(B)(iii). The review body may not take into account any
environmental or health concerns.
Site Details
Address:
3021 East Shelby Drive (Parcel ID: 060232 00005C), 0 East Shelby Drive (Parcel ID: 060232 00007)
Parcel ID:
060232 00005C, 060232 00007
Area:
+/-35.164 acres
Description:
The subject property , 3021 East Shelby Drive, is known as Parcel 5 and 6 of Shelby Rail Service Planned
Development (PD 2006 -349). Per the assessor’s site, the subject property has an industrial classification. The
subject property has an office land use classification . The subject property is currently operated by the Shelby
Railroad Services, Inc. The proposed added land, 060232 00007, has a vacant land use classification and is
landlocked between the Shelby Railroad Services, Inc. property and the Shelby County Landfill/Jackson Pit
properties located south.
Staff Report July 10, 2025
PD 2025-002 Page 20
20
Site Zoning History
In May 1986, The Memphis City Council approved Ordinance No. 3553 for a zoning change from Residential
Single Family – 8 (R-8) zoning to Commercial Mixed Use – 1 (CMU-1) formally known as Local Commercial (C-L)
(Z 1986 – 100).
In May 1995, the Memphis and Shelby County Land Use Control Board approved the Cavalier Center Planned
Development (PD 1995 – 315), a two-phase planned development that permitted commercial uses and a mini-
warehouse.
In February 2006, the Memphis City Council approved the Shelby Rail Service, Inc. Planned Development (PD
2006-0349) to establish a planned development for construction contractor office with outdoor storage facility.
Concept Plan Review
- All existing facilities located at 3021 East Shelby Drive will remain.
o There are four (4) material storage areas designated along the south property line of 3021 East
Shelby Drive.
o There is an existing enclosed storage area along the eastern property line.
- Approximately 25.25 acres being proposed to be added to the existing Shelby Railyard Planned
Development.
- There is a total of three curb cuts serving the proposed vehicle self-storage area.
o One (1) existing 95-foot-wide curb cut with a 40-foot-wide drive
▪ Entrance curb cut with a gravel turnaround area
o Two (2) proposed exit only curb cuts with a 15-foot-wide drive
▪ One (1) 42-foot-wide curb cut
▪ One (1) 48-foot-wide curb cut
- There are two (2) 20-foot-wide sliding gates
- A new fence is being proposed at the entrance of the vehicle self-storage area
- There is an existing fence along the east property line
- All existing landscaping along Shelby Drive will remain
- There are five (5) “rows” being proposed for vehicle self -storage with a tot al o f nine (9) storage
containers
Analysis
The applicant is proposing to amend the existing Shelby Rail Service Planned Development to add additional
land for contractor storage of materials. The permitted uses in the area to be added will be governed by
Employment zoning district regulations. The land to be added is currently landlocked between Shelby Railroad
Service, Inc. (PD 06 -349) located north, and the Shelby County Landfill/Jackson Pit Dump properties located
south. The subject property is primarily surrounded by residential, institutional and multifamily land uses. There
are a few properties with commercial land use designation at the intersection Tchulahoma Road and East Shelby
Drive.
The applicant has already completed substantial work on the site, including a new curb cut on Shelby Drive and
several feet of fill, without permits or approval.
Staff is not in support of the proposed use for this site given its proximity to the residential areas. There was
recently a proposed Planned Development case (PD 2024 -013) that was rejected at Memph is city council
Staff Report July 10, 2025
PD 2025-002 Page 21
21
approval to allow for a drop yard for the property located +/ -499.6 feet east of 3021 East Shelby Drive. Aside
from Comprehensive Planning finding this proposal incompatible with the land use and adjacent zoning. The
proposal contradicts the Oakhaven neighborhood priority of preserving and protecting residential
neighborhoods from industrial uses using natural buffers. The proposed project would aide in the expansion of
commercial/industrial uses into the residential area nearby. Staff is proposing a revised concept plan, see page
16, that would alleviate the impact of expansion of commercial/industrial uses. Staff is proposing there be three
(3) areas within the planned development; Area A, B, and C. The revised concept plan proposed by staff would
relocate the entrance and turnaround area being proposed along Shelby Drive further into the site. This would
prevent any heavy commercial/industrial operations operating along Shelby Drive.
The project will have a substantial or undue adverse effect upon adjacent property, the character of the
neighborhood, traffic conditions, parking, utility facilities and other matters affecting the public health, safety,
and general welfare.
RECOMMENDATION
Staff recommends rejection; however, if approved, staff recommends the following conditions and outline plan
conditions:
Conditions:
1. No additional permits shall be issued until the existing construction of the vehicle-storage facilities has
been permitted, inspected, and approved.
2. No development activity may occur until the applicant obtains any permit, conducts any study, and
allows any environmental review deemed necessary by City of Memphis Public Works or the Tennessee
Department of Environment and Conservation Division of Remediation. Furthermore, the applicant must
follow all practical and effective remedies to stabilize, remediate, contain, monitor, and maintain the
site to minimize any threats to public health, safety, and the environment as deemed applicable and
appropriate by said agencies—note that any development activity explicitly authorized by either agency
related to the preceding remedies is permitted. The applicant must provide written confirmation from
City of Memphis Public Works and the Tennessee Department of Environment and Conservation Division
of Remediation verifying compliance with this condition after all practical and effective remedies, if
deemed necessary, have been completed and provide it to the Division of Planning and Development.
After the aforementioned written confirmation, the final plat may be recorded and then development
activity may occur.
Outline Plan Conditions
I. USES PERMITTED:
A. Area A: Construction contractor with outdoor storage facility.
B. Area B: Vehicle and Equipment Outdoor Storage under lease such as Boats, Buses, Campers ,
Contractor Equipment, Recreational Vehicles , Trucks and other Vehicle Storage uses.
C. Area C: Uses permitted by right in the CMU -2 District
D. In Areas A and B, uses permitted by right in the EMP district, except that the following uses shall
be prohibited:
1. Adult entertainment (excluded)
2. Off-Premise Advertising Signs
3. Amusements, Commercial outdoor
4. Campground, Travel Trailer park
Staff Report July 10, 2025
PD 2025-002 Page 22
22
5. Drive-in Theater
6. Garage, Commercial
7. Tavern, cocktail lounge, nightclub
8. Brewery
9. Bus terminal or Service Facility
10. Taxicab Dispatch Station
11. Garage or Refuse Collection Service
12. Used Goods, Secondhand Sales
13. Chemical Manufacturing
14. Slaughtering Business
15. Beverage Recycling Center
16. Trailer storage, drop off lot
II. BULK REGULATIONS:
A. The minimum front yard setback shall be 50 feet.
B. The minimum side yard setbacks shall be 10 feet.
C. The maximum height of any outdoor storage shall be 15 feet.
III. ACCESS, PARKING AND CIRCULATION:
A. Two curb cuts are permitted onto Shelby Drive.
A. The City Engineer shall approve the design, number and location of curb cuts. Any existing
nonconforming curb cuts shall be modified to meet current City Standards or closed with curb,
gutter, and sidewalk.
B. No curb cut shall be located closer than 500 feet from the centerline of Swinnea Road.
C. The parking requirements of the EMP District shall apply.
D. All parking areas and driving aisles to be paved with asphalt or concrete.
E. Adequate queuing spaces in accordance with the current ordinance shall be provided between
the street right-of-way line and any proposed gate/guardhouse/card reader.
F. Adequate maneuvering room shall be provided between the right-of-way and the
gate/guardhouse/card reader for vehicles to exit by forward motion.
IV. SIGNS:
A. One ground-mounted monument style sign is permitted with a maximum area of 100 feet, to
be designed and located with due consideration for sight distance requirements. The final plan
shall indicate the location and dimensions of any freestanding on -premise sign, subject to the
review and approval of the Division of Planning and Development.
B. Any additional signs shall be in accordance with the CMU-2 District.
C. No permanent off-premise advertising signs are permitted.
D. No temporary or portable signs are permitted.
E. All signs shall be set back a minimum of 10 feet from the right-of-way.
V. LANDSCAPING AND DESIGN:
A. The landscaping screen along Shelby Drive shall be as shown on the proposed site plan and shall
include an irrigation system for the area.
B. The front elevation of the principal building shall be brick or masonry, and a graphic rendering
of that building shall be part of the final plan.
Staff Report July 10, 2025
PD 2025-002 Page 23
23
C. Outdoor lighting should be directed so that it does not glare onto nearby properties.
D. The existing trees along Shelby Drive for the amendment area shall be shown on the final Plat.
VI. DRAINAGE:
A. Drainage improvements, including on -site detention, shall be provided under a Standard
Subdivision contract in accordance with Subdivision Regulations and the City of Memphis
Drainage Design Manual.
B. Drainage data for assessment of on-site detention requirements shall be submitted to and
approved by the City Engineer.
VII. SITE PLAN REVIEW:
F. A site plan shall be submitted for the review, comment and recommendation of the Division
Office of Planning and Development and appropriate City and County agencies for approval of
the Land Use Control Board prior to approval of any final plan for development that includes
acquisition of adjacent land to the west.
VIII. FINAL PLAN:
A. A final plan shall be recorded within 5 years from the date of the recording of the outline plan,
provided that the Land Use Control Board may approve an extension of this deadline.
B. Any final plan shall include the following:
1. The outline plan conditions,
2. A standard subdivision contract as defined by the Subdivision Regulations for any needed
public improvements.
3. The location and ownership, whether public or private, of any easement, and
4. The exact locations and dimensions including height of buildings, parking areas, utility
easements, drives, trash receptacles, loading facilities and required landscaping and
screening areas;
5. The content of all landscaping and screening is to be provided,
6. If applicable, a statement conveying facilities and areas to a property owners' association
or other entity for ownership and maintenance purposes,
7. The following note shall be placed on the f inal plat of any development requiring on- site
storm water facilities: The areas denoted by "Reserved for Storm Water Detention" shall
not be used as a building site or filled without first obtaining written permission from
the City Engineer. The storm water detention systems located in these areas, except for
those parts located in a public drainage easement shall be owned and maintained by
the property owner and/or property owner's association. Such maintenance shall be
performed so as to ensure that the system operates in accordance with the approved
plan on file in the City Engineer's Office. Such maintenance shall include, but not be
limited to removal of sedimentation; fallen objects; debris; trash; mowing; outlet cleaning;
and repair of drainage structures.
.
Staff Report July 10, 2025
PD 2025-002 Page 24
24
DEPARTMENTAL COMMENTS
The following comments were provided by agencies to which this application was referred:
City Engineer:
1. Standard Public Improvement Contract or Right -Of-Way Permit as required in Section 5.5.5 of the Unified
Development Code.
Sewers:
2. City sanitary sewers are available to serve this development.
Roads:
3. The Developer shall be responsible for the repair and/or replacement of all existing curb and gutter along the
frontage of this site as necessary.
4. All existing sidewalks and curb openings along the frontage of this site shall be inspected for ADA compliance.
The developer shall be responsible for any reconstruction or repair necessary to meet City standards.
Traffic Control Provisions:
5. The developer shall provide a traffic control plan to the city engineer that shows the phasing for each street
frontage during demolition and construction of curb gutter and sidewalk. Upon completion of sidewalk and curb
and gutter improvements, a minim um 5-foot-wide pedestrian pathway shall be provided throughout the
remainder of the project. In the event that the existing right of way width does not allow for a 5 foot clear
pedestrian path, an exception may be considered.
6. Any closure of the right of way shall be time limited to the active demolition and construction of sidewalks
and curb and gutter. Continuous unwarranted closure of the right of way shall not be allowed for the duration
of the project. The developer shal l provide on the traffic control plan, the time needed per phase to complete
that portion of the work. Time limits will begin on the day of closure and will be monitored by the Engineering
construction inspectors on the job.
7. The developer’s engineer shall submit a Trip Generation Report that documents the proposed land use, scope
and anticipated traffic demand associated with the proposed development. A detailed Traffic Impact Study will
be required when the accepted Trip G eneration Report indicates that the number for projected trips meets or
exceeds the criteria listed in Section 210 -Traffic Impact Policy for Land Development of the City of Memphis
Division of Engineering Design and Policy Review Manual. Any required Traff ic Impact Study will need to be
formally approved by the City of Memphis, Traffic Engineering Department.
Curb Cuts/Access:
8. The City Engineer shall approve the design, number, and location of curb cuts.
9. Any existing nonconforming curb cuts shall be modified to meet current City Standards or closed with curb,
gutter, and sidewalk.
Drainage:
10. A grading and drainage plan for the site shall be submitted to the City Engineer for review and approval prior
to recording of the final plat.
11. Drainage improvements, including possible on -site detention, shall be provided under a Standard
Subdivision contract in accordance with Unified Development Code and the City of Memphis/Shelby County
Storm Water Management Manual.
12. Drainage data for assessment of on-site detention requirements shall be submitted to the City Engineer.
13. The following note shall be placed on the final plat of any development requiring on -site storm water
detention facilities: The areas denoted by "Reserved for Storm Water Detention" shall not be used as a building
site or filled without first obtaining written permission from the City and/or County Engineer. The storm water
detention systems located in these areas, except for those parts located in a public drainage easement, shall be
owned and maintained by the property owner and/or property owners' association. Such maintenance shall be
Staff Report July 10, 2025
PD 2025-002 Page 25
25
performed so as to ensure that the system operates in accordance with the approved plan on file in the City
and/or County Engineer's Office. Such maintenance shall include, but not be limited to removal of
sedimentation, fallen objects, debris and trash, mowing, outlet cleaning, and repair of drainage structures.
14. The developer should be aware of his obligation under 40 CFR 122.26(b)(14) and TCA 69 -3-101 et. seq. to
submit a Notice of Intent (NOI) to the Tennessee Division of Water Pollution Control to address the discharge of
storm water associated with the clearing and grading activity on this site.
General Notes:
15. Development is greater than 1 acre and requires detention.
16. No other utilities or services may occupy sanitary sewer easements in private drives and yards except for
crossings.
17. All connections to the sewer shall be at manholes only.
18. All commons, open areas, lakes, drainage detention facilities, private streets, private sewers and private
drainage systems shall be owned and maintained by a Property Owner's Association. A statement to this effect
shall appear on the final plat.
19. Required landscaping shall not be placed on sewer or drainage easements
City Fire Division: No comments received.
City Real Estate: No comments received.
County Health Department: No comments received.
Shelby County Schools: No comments received.
Construction Code Enforcement: No comments received.
Memphis Light, Gas and Water: No comments received.
Office of Sustainability and Resilience: No comments received.
Office of Comprehensive Planning: See pages 26 – 28.
Staff Report July 10, 2025
PD 2025-002 Page 26
26
Comprehensive Planning Review of Memphis 3.0 Consistency
This summary is being produced in response to the following application to support the Land Use and
Development Services department in their recommendation: PD 2025-002: Oakhaven/Parkway Village
Site Address/Location: 3021 E Shelby
Overlay District/Historic District/Flood Zone: Not in an Overlay District, Historic District, or Flood Zone
Future Land Use Designation: Anchor Neighborhood-Primarily Single-Unit (AN-S)
Street Type: N/A
The applicant is requesting a planned development to add additional land for storage.
The following information about the land use designation can be found on pages 76 – 122:
1. Future Land Use Planning Map
Red polygon indicates the application site on the Future Land Use Map.
2. Land Use Description/Intent
Anchor Neighborhood -Primarily Single -Unit (AN -S) are walkable
neighborhoods within a 5 – 10-minute walk of a Community
Anchor. These neighborhoods are made up of single -unit and
duplex housing. Graphic portrayal of AN-S is to the right.
“AN-S” Form & Location Characteristics
NURTURE
Primarily detached, single-family residences. Attached single-family residences permitted on parcels within 100
Staff Report July 10, 2025
PD 2025-002 Page 27
27
feet of an anchor. Height: 1-2 stories. Scale: house-scale.
“AN-S” Zoning Notes
Generally compatible with the following zone districts: R-15, R-10, R-8, R-6, R-3, RU-1, MDR in accordance with
Form and characteristics listed above.
Existing, Adjacent Land Use and Zoning
Existing Land Use and Zoning: Vacant; R-8
Adjacent Land Use and Zoning: Vacant, Industrial, Multi-Family, Commercial; CMU-1, R-8, CA, RMP
Overall Compatibility: This request is not compatible with the land use description/intent, form & location
characteristics, zoning notes, and existing, adjacent land use and zoning as the proposed building is for additional
storage. Additionally, the proposed building conflicts with Oakhaven's priority of preserving and protecting
residential neighborhoods from industrial uses using natural buffers.
3. Degree of Change Map
Red polygon denotes the proposed site on the Degree of Change Map. Degree of Change is Nurture.
4. Degree of Change Description
Nurture areas rely primarily on public and philanthropic resources to stabilize the existing pattern of a place.
5. Objectives/Actions Consistent with Goal 1, Complete, Cohesive, Communities
N/A
6. Pertinent Sections of Memphis 3.0 that Address Land Use Recommendations
N/A
Consistency Analysis Summary
The applicant is requesting a planned development to add additional land for storage.
This request is not compatible with the land use description/intent, form & location characteristics, zoning
Staff Report July 10, 2025
PD 2025-002 Page 28
28
notes, and existing, adjacent land use and zoning as the proposed building is for additional storage. Additionally,
the proposed building conflicts with Oakhaven's priority of preserving and protecting residential neighborhoods
from industrial uses using natural buffers.
Nurture areas rely primarily on public and philanthropic resources to stabilize the existing pattern of a place.
Based on the information provided, the proposal is INCONSISTENT with the Memphis 3.0 Comprehensive
Plan.
Summary Compiled by: Negin Hamidi, Comprehensive Planning.
Staff Report July 10, 2025
PD 2025-002 Page 29
29
MAILED PUBLIC NOTICE
Staff Report July 10, 2025
PD 2025-002 Page 30
30
SIGN AFFIDAVIT
Staff Report July 10, 2025
PD 2025-002 Page 31
31
APPLICATION
Staff Report July 10, 2025
PD 2025-002 Page 32
32
Staff Report July 10, 2025
PD 2025-002 Page 33
33
Staff Report July 10, 2025
PD 2025-002 Page 34
34
OWNER AFFIDAVIT
Staff Report July 10, 2025
PD 2025-002 Page 35
35
LETTER OF INTENT
Staff Report July 10, 2025
PD 2025-002 Page 36
36
LETTERS RECEIVED
No letters received at the time of completion of this report.
East Service Center: 6465 Mullins Station Rd; Memphis,
Tennessee
38134
Downtown Service Center: 125 N. Main Street;
Memphis, T
ennessee 38103
website: www.develop901.com
Memphis and Shelby County Division of
Planning and Development
Record Summary for Planned Development
Record Detail Information
Record T
ype: Planned Development Record Status: Pending
Opened Date:
February 28, 2025
Record Number: PD 2025-002
Record Name: Shelby Rail Service PD
Expiration Date:
Description of Work: PD amendment to add adjacent property for additional storage.
Parent Record Number:
Address:
3021 E SHELBY DR, MEMPHIS 381
18
Owner Information
Primary Owner Name
Owner Address Owner Phone
Y TAR
VER JOHN T AND J KIRK TARVER (RS)
2100 WOODCREEK DR, GERMANTOWN, TN 38138
Parcel Information
060232 00005C
Data Fields
PREAPPLICA
TION MEETING
Name of DPD Planner Lucas Skinner
Date of Meeting -
Pre-application Meeting
Type -
GENERAL PROJECT INFORMATION
Planned Development Type Amendment to Existing PD
Previous Docket / Case Number PD 06-349
Medical Overlay / Uptown No
If this development is located in unincorporated
Shelby County, is the tract at least three acres?
(Note a tract of less than three acres is not
N/A
Page 1 of 3 PD 2025-002
GENERAL PROJECT INFORMATION
eligible for a planned development in
unincorporated Shelby County)
Is this application in response to a citation, stop
work order, or zoning letter
No
If yes, please provide a copy of the citation, stop
work order, and/or zoning letter along with any
other relevant information
-
APPROVAL CRITERIA
UDC Sub-Section 9.6.9A No af
fect to adjacent property.
UDC Sub-Section 9.6.9B The development will be consistent with the existing
PD property.
UDC Sub-Section 9.6.9C If needed adequate facilities will be provided.
UDC Sub-Section 9.6.9D No significant features on the site.
UDC Sub-Section 9.6.9E The development will be consistent with the existing
PD property.
UDC Sub-Section 9.6.9F No affect to plans to be considered
GENERAL PROVISIONS
UDC Sub-Section 4.10.3A No affect to surrounding property.
B) An approved water supply, community waste
water treatment and disposal, and storm water
drainage facilities that are adequate to serve the
proposed development have been or will be
provided concurrent with the development
If needed adequate facilities will be provided.
C) The location and arrangement of the
structures, parking and loading areas, walks,
lighting and other service facilities shall be
compatible with the surrounding land uses, and
any part of the proposed development not used
for such facilities shall be landscaped or
otherwise improved except where natural
features are such as to justify preservation
The development will be consistent with the existing
PD property.
D) Any modification of the district standards that
would otherwise be applicable to the site are
warranted by the design of the outline plan and
the amenities incorporated therein, and are not
inconsistent with the public interest
The development will be consistent with the existing
PD property.
E) Homeowners’ associations or some other
responsible party shall be required to maintain
any and all common open space and/or common
elements
The owner will maintain the property.
F) Lots of record are created with the recording
of a planned development final plan
A Final Plat will be recorded.
GIS INFORMATION
Case Layer -
Central Business Improvement District No
Class -
Downtown Fire District No
Page 2 of 3 PD 2025-002
GIS INFORMATION
Historic District -
Land Use -
Municipality -
Overlay/Special Purpose District -
Zoning -
State Route -
Lot -
Subdivision -
Planned Development District -
W
ellhead Protection Overlay District No
County Commission District -
City Council District -
City Council Super District -
Contact Information
SHELBY RAILROAD SER
VICE INC.
-
APPLICANT
Name
Address
Phone
Contact Type
CINDY REA
VES
(901)870-7003
REPRESENTATIVE
Name
Address
Phone
Contact Type
Fee Information
Date
AssessedBalanceStatusFeesQuantityFee ItemInvoice #
03/03/20250.00INVOICED2,100.0021Planned Development -
each additional or
fractional acres above 5
1628194
03/03/20250.00INVOICED1,500.001Planned Development - 5
acres or less
1628194
Total Fee Invoiced
: $3,600.00 Total Balance: $0.00
Payment Information
Payment
Amount Method of Payment
Check$3,600.00
Page 3 of 3 PD 2025-002
Date: February 27, 2025
To: Division of Planning & Development
From: Cindy Reaves
Re: Shelby Rail Service PD
LETTER OF INTENT
We are submitting a Planned Development Amendment application for Shelby Rail
Service PD (PD 06-349), located at 3021 E. Shelby Drive. We are requesting to add the
adjacent landlocked property to the Planned Development to be used for an expansion of
the Shelby Rail property. The property is in between Shelby Rail Services and the
Shelby County landfill/Jackson Pit property.
We appreciate your support with this request. Please contact me if you have any
questions.
CONDITIONS:
I. USES PERMITTED:
A. Construction contractor with outdoor storage facility.
B. Uses permitted by right in the EMP district, except that the following uses shall be
prohibited:
1. Adult entertainment (excluded)
2. Off-Premise Advertising Signs
3. Amusements, Commercial outdoor
4. Campground, Travel Trailer park
5. Drive-in Theater
6. Garage, Commercial
7. Tavern, cocktail lounge, night Club
8. Brewery
9. Bus terminal or Service Facility
10. Taxi Cab Dispatch Station
11. Garage or Refuse Collection Service
12. Used Goods, Second hand Sales
13. Chemical Manufacturing
14. Slaughtering Business
15. Beverage Recycling Center
II. BULK REGULATIONS:
A. The minimum front yard setback shall be 50 feet.
B. The minimum side yard setbacks shall be 10 feet.
C. The maximum height of any outdoor storage shall be 15 feet.
III. ACCESS, PARKING AND CIRCULATION:
A. Two curb cuts are permitted onto Shelby Drive.
B. The City Engineer shall approve the design, number and location of curb cuts. Any
existing nonconforming curb cuts shall be modified to meet current City Standards or
closed with curb, gutter and sidewalk.
C. No curb cut shall be located closer than 500 feet from the centerline of Swinnea
Road.
D. The parking requirements of the EMP District shall apply.
E. All parking areas and driving aisles to be paved with asphalt or concrete.
F. Adequate queuing spaces in accordance with the current ordinance shall be
provided between the street right-of-way line and any proposed gate/guardhouse/card
reader.
G. Adequate maneuvering room shall be provided between the right-of-way and the
gate/guardhouse/card reader for vehicles to exit by forward motion.
I V. SIGNS:
A. One ground-mounted monument style sign is permitted with a maximum area of
100 feet, to be designed and located with due consideration for sight distance
requirements. The final plan shall indicate the location and dimensions of any freestanding
on-premise sign, subject to the review and approval of the Division of Planning and
Development.
B. No permanent off-premise advertising signs are permitted.
C. No temporary or portable signs are permitted.
D. All signs shall be set back a minimum of 10 feet from the right-of-way.
V. LANDSCAPING AND DESIGN:
A. The landscaping screen along Shelby Drive shall be as shown on the proposed site
plan and shall include an irrigation system for the area.
B. The front elevation of the principal building shall be brick or masonry, and a graphic
rendering of that building shall be part of the final plan.
D. Outdoor lighting should be directed so that it does not glare onto nearby properties.
VI. DRAINAGE:
A. Drainage improvements, including on-site detention, shall be provided under a
Standard Subdivision contract in accordance with Subdivision Regulations and the City of
Memphis Drainage Design Manual.
B. Drainage data for assessment of on-site detention requirements shall be submitted
to and approved by the City Engineer.
VII. SITE PLAN REVIEW:
A. A site plan shall be submitted for the review, comment and recommendation of the
Division of Planning and Development and appropriate City and County agencies for
approval of the Land Use Control Board prior to approval of any final plan for development
that includes acquisition of adjacent land to the west.
VIII. FINAL PLAN:
A. A final plan shall be recorded within 5 years from the date of the recording of the
outline plan, provided that the Land Use Control Board may approve an extension of this
deadline.
B. Any final plan shall include the following:
1. The outline plan conditions,
2. A standard subdivision contract as defined by the Subdivision Regulations for any
needed public improvements.
3. The location and ownership, whether public or private, of any easement, and
4. The exact locations and dimensions including height of buildings, parking areas,
utility easements, drives, trash receptacles, loading facilities and required landscaping and
screening areas;
5. The content of all landscaping and screening is to be provided,
6. If applicable, a statement conveying facilities and areas to a property owners'
association or other entity for ownership and maintenance purposes,
7. The following note shall be placed on the final plat of any development requiring on-
site storm water facilities: The areas denoted by "Reserved for Storm Water Detention"
shall not be used as a building site or filled without first obtaining written permission from
the City Engineer. The storm water detention systems located in these areas, except for
those parts located in a public drainage easement shall be owned and maintained by the
property owner and/or property owner's association. Such maintenance shall be
performed so as to ensure that the system operates in accordance with the approved plan
on file in the City Engineer's Office. Such maintenance shall include, but not be limited to
removal of sedimentation; fallen objects; debris; trash; mowing; outlet cleaning; and repair
of drainage structures.
City Hall – 125 N. Main Street, Suite 468 – Memphis, Tennessee 38103 – (901) 636-6619
July 11, 2025
Sent via electronic mail to:
Shelby Rail Services Planned Development
Case Number: PD 2025-002
LUCB Recommendation: Rejection
Dear applicant,
On Thursday, July 10, 2025, the Memphis and Shelby County Land Use Control Board recommended
rejection of your planned development amendment application for the Shelby Rail Services Planned
Development, subject to the attached conditions.
This application will be forwarded, for final action, to the Council of the City of Memphis. The Council
will review your application in a committee meeting prior to voting on it in a public hearing. The
applicant or the applicant’s representative(s) shall be in attendance at all meetings and hearings.
It is the applicant’s responsibility to contact the City Council Records Office to determine when the
application is scheduled to be heard at committee and in public session. The City Council Records
Office may be reached at (901) 636-6792.
If for some reason you choose to withdraw your application, a letter should be mailed to the Land
Use and Development Services Department of the Division of Planning and Development at the
address provided above or emailed to the address provided below.
If you have questions regarding this matter, please feel free to contact me at (901) 636-6619 or via
email at alexis.longstreet@memphistn.gov.
Respectfully,
Alexis Longstreet
Alexis Longstreet
Planner
Land Use and Development Services
Division of Planning and Development
Cc:
File
Letter to Applicant
PD 2025-002
Page 2 of 4
Outline Plan Conditions – Revisions
Proposed language is indicated in bold, underline; deletions are indicated in bold strikethrough
I. USES PERMITTED:
A. Area A: Construction contractor with outdoor storage facility.
B. Area B: Vehicle and Equipment Outdoor Storage under lease such as Boats, Buses,
Campers, Contractor Equipment, Recreational Vehicles, Trucks , and other Vehicle
Storage uses.
C. Area C: Uses permitted by right in the CMU -2 District
D. In Areas A and B, uses permitted by right in the EMP district, except that the following
uses shall be prohibited:
1. Adult entertainment (excluded)
2. Off-Premise Advertising Signs
3. Amusements, Commercial outdoor
4. Campground, Travel Trailer park
5. Drive-in Theater
6. Garage, Commercial
7. Tavern, cocktail lounge, nightclub
8. Brewery
9. Bus terminal or Service Facility
10. Taxicab Dispatch Station
11. Garage or Refuse Collection Service
12. Used Goods, Secondhand Sales
13. Chemical Manufacturing
14. Slaughtering Business
15. Beverage Recycling Center
16. Tractor-Trailer or Container storage, drop lot
II. BULK REGULATIONS:
A. The minimum front yard setback shall be 50 feet.
B. The minimum side yard setbacks shall be 10 feet.
C. The maximum height of any outdoor storage shall be 15 feet.
III. ACCESS, PARKING AND CIRCULATION:
A. Two curb cuts are permitted onto Shelby Drive.
B. The City Engineer shall approve the design, number and location of curb cuts. Any
existing nonconforming curb cuts shall be modified to meet current City Standards
or closed with curb, gutter, and sidewalk.
C. No curb cut shall be located closer than 500 feet from the centerline of Swinnea Road.
D. The parking requirements of the EMP District shall apply.
E. All parking areas and driving aisles to be paved with asphalt or concrete.
F. Adequate queuing spaces in accordance with the current ordinance shall be provided
between the street right-of-way line and any proposed gate/guardhouse/card reader.
G. Adequate maneuvering room shall be provided between the right-of-way and the
gate/guardhouse/card reader for vehicles to exit by forward motion.
Letter to Applicant
PD 2025-002
Page 3 of 4
IV. SIGNS:
A. One ground -mounted monument style sign is permitted with a maximum area of
100 feet, to be designed and located with due consideration for sight distance
requirements. The final plan shall indicate the location and dimensions of any
freestanding on-premise sign, subject to the review and approval of the Division of
Planning and Development.
A. Any additional signs shall be in accordance with the CMU-2 District.
B. No permanent off-premise advertising signs are permitted.
C. No temporary or portable signs are permitted.
D. All signs shall be set back a minimum of 10 feet from the right-of-way.
V. LANDSCAPING AND DESIGN:
A. The landscaping screen along Shelby Drive shall be as shown on the proposed site
plan, shall be installed along the entire frontage and shall include an irrigation
system for the area.
B. The front elevation of the principal building shall be brick or masonry, and a graphic
rendering of that building shall be part of the final plan.
C. Outdoor lighting should be directed so that it does not glare onto nearby properties.
D. The existing trees along Shelby Drive for the amendment area shall be shown on the final
Plat.
VI. DRAINAGE:
A. Drainage improvements, including on -site detention, shall be provided under a
Standard Subdivision contract in accordance with Subdivision Regulations and the
City of Memphis Drainage Design Manual.
B. Drainage data for assessment of on -site detention requirements shall be submitted
to and approved by the City Engineer.
VII. SITE PLAN REVIEW:
E. A site plan shall be submitted for the review, comment and recommendation of the
Division Office of Planning and Development and appropriate City and County
agencies. for approval of the Land Use Control Board prior to approval of any final
plan for development that includes acquisition of adjacent land to the west.
VIII. FINAL PLAN:
A. A final plan shall be recorded within 5 years from the date of the recording of the
outline plan, provided that the Land Use Control Board may approve an extension of
this deadline.
B. Any final plan shall include the following:
1. The outline plan conditions,
2. A standard subdivision contract as defined by the Subdivision Regulations for
any needed public improvements.
3. The location and ownership, whether public or private, of any easement, and
4. The exact locations and dimensions including height of buildings, parking
Letter to Applicant
PD 2025-002
Page 4 of 4
areas, utility easements, drives, trash receptacles, loading facilities and
required landscaping and screening areas;
5. The content of all landscaping and screening is to be provided,
6. If applicable, a statement conveying facilities and areas to a property
owners' association or other entity for ownership and maintenance
purposes,
7. The following note shall be placed on the f inal plat of any development
requiring on- site storm water facilities: The areas denoted by "Reserved for
Storm Water Detention" shall not be used as a building site or filled without
first obtaining written permission from the City Engineer. The storm water
detention systems located in these areas, except for those parts located in
a public drainage easement shall be owned and maintained by the property
owner and/or property owner's association. Such maintenance shall be
performed so as to ensure that the system operates in accordance with the
approved plan on file in the City Engineer's Office. Such maintenance shall
include, but not be limited to removal of sedimentation; fallen objects;
debris; trash; mowing; outlet cleaning; and repair of drainage structures.
Memphis City Council
Summary Sheet
PD 25-14
RESOLUTION PURSUANT TO CHAPTER 9.6 OF THE MEMPHIS AND SHELBY COUNTY UNIFIE D
DEVELOPMENT CODE APPROVING A PLANNED D EVELOPMENT AT THE SUBJECT PROPERTY
LOCATED AT 7913 DEXTER ROAD, KNOWN AS CASE NUMBER PD 25-14
• This item is a resolution with conditions to allow a 28-lot residential development;
and
• This resolution, if approved with conditions, will supersede the existing zoning for
this property; and
• The item may require future public improvement contracts.
1
LAND USE CONTROL BOARD RECOMMENDATION
At its regular meeting on Thursday, November 13 , 20 25, the Memphis and Shelby County Land Use
Control Board held a public hearing on the following application:
CASE NUMBER: PD 25-14
DEVELOPMENT: Dexter-Candle Ridge Planned Development
LOCATION: 7913 Dexter Rd
COUNCIL DISTRICT(S): District 2 and Super District 9
OWNER/APPLICANT: Providence Private Equity Group LLC
REPRESENTATIVE: David Gean Bray, The Bray Firm
REQUEST: 28-lot residential development
EXISTING ZONING: Conservation Agriculture (CA)
AREA: +/-6 acre
s
The following spoke in support: David Gean Bray
The following spoke in opposition: Blondell Phillips, Margaret Williams
The Land Use Control Board reviewed the application and the staff report. A motion was made and
seconded to recommend approval with conditions.
The motion passed by a unanimous vote of 7-0 on the regular agenda.
Respectfully,
Nabanita Nira
Planner II
Land Use and Development Services
Division of Planning and Development
Cc: Committee Members
File
2
PD 25-14
CONDITIONS
Outline Plan Conditions
DEXTER - CANDLE RIDGE PLANNED DEVELOPMENT
I. USES PERMITTED
28 SINGLE FAMILY LOTS
II. BULK REGULATIONS
A. MINIMUM LOT AREA SHALL BE 6000 S.F.
B. MINIMUM LOT WIDTH SHALL BE 40 FEET
C. MINIMUM SETBACKS
1. FRONT: 40 FEET
2. REAR: 20 FEET
3. SIDE: 5 FEET
III. ACCESS AND CIRCULATION
DEXTER ROAD SHALL BE DEDICATED AND IMPROVED 57 FEET FROM CENTERLINE
IV. LANDSCAPING AND SCREENING
A. EVERGREEN SHRUBS SHALL BE PROVIDED ALONG THE FRONTAGE OF DEXTER ROAD IN LIEU OF
STREET TREES (DUE TO OHE)
B. EACH LOT SHALL HAVE A MINIMUM OF ONE STREET TREE PLANTED BY THE BUILDING PERMIT
HOLDER.
V. DRAINAGE
A. ALL DRAINAGE PLANS TO BE SUBMITTED TO CITY ENGINEER(S) FOR REVIEW.
B. AN OVERALL DRAINAGE PLAN FOR THE ENTIRE SITE SHALL BE SUBMITTED TO THE CITY ENGINEER
BEFORE ANY FINAL PLAN IS RECORDED.
C. DRAINAGE IMPROVEMENTS TO BE PROVIDED UNDER CONTRACT IN ACCORDANCE WITH THE
SUBDIVISION REGULATIONS, AND THE CITY OF MEMPHIS DRAINAGE DESIGN MANUAL.
D. DESIGN OF THE STORM WATER CONVEYANCE AND MANAGEMENT FACILITIES FOR THIS PROJECT
SHALL BE IN ACCORDANCE WITH THE "CITY OF MEMPHIS DRAINAGE DESIGN MANUAL". THE
MANUAL REQUIRED ON-SITE DETENTION OF STORMWATER RUN -OFF, GENERATED FROM THIS
PROJECT, WHICH EXCEED S THE CAPACITY OF THE DOWN STREAM SYSTEM. DRAINAGE
CALCULATIONS PERFORMED IN ACCORDANCE WITH THE MANUAL SHALL BE SUBMITTED
VERIFYING THAT ADEQUATE NON-BUILDABLE AREAS HAVE BEEN PROVIDED FOR STORM WATER
DETENTION FACILITIES. FOR INFORMATION CONCERNING THIS REQUIREMENT, PLEASE
CONTACT THE CITY ENGINEER'S OFFICE.
E. THE FOLLOWING NOTE SHALL BE PLACED ON THE FINAL PLAT OF ANY DEVELOPMENT REQUIRING
ON-SITE STORM WATER DETENTION FACILITIES. THE AREAS DENOTED BY "RESERVED FOR
STORMWATER DETENTION" SHALL NOT BE USED AS A BUILDING SITE OR FILLED WITHOUT FIRST
OBTAINING PERMISSION FROM THE CITY OR COUNTY ENGINEER, AS APPLICABLE. THE
STORMWATER DETENTION SYSTEMS LOCATED IN THESE AREAS, EXCEPT FOR THOSE PART
LOCATED IN A PUBLIC DRAINAGE EASEMENT, SHALL BE OWNED AND MAINTAINED BY THE
3
PROPERTY OWNER AND/OR PROPERTY OWNERS' ASSOCIATION. SUCH MAINTENANCE SHALL BE
PERFORMED SO AS TO ENSURE THAT THE SYSTEM OPERATES IN ACCORDANCE WITH THE
APPROVED PLAN ON FILE IN THE CITY/COUNTY ENGINEER'S OFFICE. SUCH MAINTENANCE SHALL
INCLUDE, BUT NO BE LIMITED TO REMOVAL OF SEDIMENTATION, FALLEN OBJECTS, DEBRIS AND
TRASH, MOWING, OUTLET CLEANING, AND REPAIR OF DRAINAGE STRUCTURES.
VI. SITE PLAN REVIEW
A SITE PLAN SHALL BE SUBMITTED FOR REVIEW, COMMENT AND RECOMMENDATION OF THE
DIVISION OF PLANNING AND DEVELOPMENT (DPD)
VII. THE LAND USE CONTROL BOARD MAY MODIFY THE BUILDING SETBACK, BUILDING HEIGHT, ACCESS,
PARKING, LANDSCAPING AND SIGN REQUIREMENTS IF EQUIVALENT ALTERNATIVES ARE PRESENTED.
VIII. A FINAL PLAN SHALL BE FILED WITHIN FIVE YEARS OF APPROVAL OF THE OUTLINE PLAN. THE LAND
USE CONTROL BOARD MAY GRANT EXTENSIONS AT THE REQUEST OF THE APPLICANT.
IX. ANY FINAL PLAN SHALL INCLUDE THE FOLLOWING:
A. THE OUTLINE PLAN CONDITIONS
B. A STANDARD SUBDIVISION CONTRACT AS DEFINED BY THE SUBDIVISION REGULATIONS FOR ANY
NEEDED PUBLIC IMPROVEMENTS.
C. THE LOCATION AND OWNERSHIP, WHETHER PUBLIC OR PRIVATE, OF ANY EASEMENT.
D. A STATEMENT CONVEYING ALL COMMON FACILITIES AND AREAS TO A PROPERTY OWNER'S
ASSOCIATION, OR OTHER ENTITY, FOR OWNERSHIP AND MAINTENANCE PURPOSES.
E. THE FOLLOWING NOTE SHALL BE PLACED ON THE FINAL PLAT OF ANY DEVELOPMENT REQUIRING
ON-SITE STORMWATER DETENTION FACILITIES. THE AREAS DENOTED BY "RESERVED FOR
STORMWATER DETENTION" SHALL NOT BE USED AS A BUILDING SITE OR FILLED WITHOUT FIRST
OBTAINING WRITTEN PERMISSION FROM THE CITY OR COUNTY ENGINEER, AS APPLICABLE. THE
STORMWATER DETENTION SYSTEMS LOCATED IN THESE AREAS, EXCEPT FOR THOSE PARTS
LOCATED IN A PUBLIC DRAINAGE EASEMENT, SHALL BE OWNED AND MAINTAINED BY THE
PROPERTY OWNER AND OR PROPER5TY OWNERS' ASSOCIATION. SUCH MAINTENANCE SHALL BE
PERFORMED SO AS TO ENSURE THAT THE SYSTEM OPERATES IN ACCORDANCE WITH THE
APPROVED PLAN ON FILE IN THE4 CITY / COUNTY ENGINEER'S OFFICE. SUCH MAINTENANCE
SHALL INCLUDE, BUT NOT BE LIMITED TO REMOVAL OF SEDIMENTATION, FALLEN OBJECTS,
DEBRIS AND TRASH, MOWING, OUTLET CLEANING AND REPAIR OF DRAINAGE STRUCTURES.
4
CONCEPT PLAN
RESOLUTION PURSUANT TO CHAPTER 9.6 OF THE MEMPHIS AND SHELBY COUNTY
UNIFIED DEVELOPMENT CO DE APPROVING A P LANNED DEVELOPMENT AT THE
SUBJECT PROPERTY LOCATED AT 7913 DEXTER ROAD, KNOWN AS CASE NUMBER PD
25-14
WHEREAS, Chapter 9.6 of the Memphis and Shelby County Unified Development Code, being a
section of the Joint Ordinance Resolution No. 5367, dated August 10, 2010, authorizes the Council of the
City of Memphis to grant a planned development for certain stated purposes in the various zoning districts;
and
WHEREAS, the Providence Private Equity Group LLC filed an application with the Memphis and
Shelby County Division of Planning and Development to allow a 28- lot residential single-family planned
development; and
WHEREAS, the Division of Planning and Development has received and reviewed the application
in accordance with procedures, objectives and standards for planned developments as set forth in Chapter
9.6 with regard to the proposed development's impacts upon surrounding properties, availability of public
facilities, both external and internal circulation, land use compatibility, and that the design and amenities
are consistent with the public interest; and has submitted its findings and recommendation subject to outline
plan conditions concerning the above considerations to the Memphis and Shelby County Land Use Control
Board; and
WHEREAS, a public hearing in relation thereto was held before the Memphis and Shelby County
Land Use Control Board on November 13, 2025, a nd said Board has submitted its findings and
recommendation subject to outline plan conditions concerning the above considerations to the Council of
the City of Memphis; and
WHEREAS, the Council of the City of Memphis has reviewed the aforementioned application
pursuant to Tennessee Code Annotated Section 13-4- 202(B)(2)(B)(iii) and has determined that said
development is consistent with the Memphis 3.0 General Plan; and
WHEREAS, the Council of the City of Memphis has reviewed the recommendation of the Land
Use Control Board and the report and recommendation of the Division of Planning and Development and
has determined that said development meets the objectives, standards and criteria for a special use permit,
and said development is consistent with the public interests.
NOW, THEREFORE, BE IT RESOLVED, BY THE COUNCIL OF THE CITY OF
MEMPHIS, that, pursuant to Chapter 9.6 of the Memphis and Shelby County Unified Development Code,
a planned development is hereby granted in accordance with the attached outline plan conditions.
BE IT FURTHER RESOLVED , t hat the requirements of said aforementioned clause of the
Unified Development Code shall be deemed to have been complied with; that the outline plan shall bind
the applicant, owner, mortgagee, if any, and the legislative body with respect to the contents of said plan;
and the applicant and/or owner may file a final plan in accordance with said outline plan and the provisions
of Section 9.6.11 of the Unified Development Code.
OUTLINE PLAN CONDITIONS
DEXTER - CANDLE RIDGE PLANNED DEVELOPMENT
I. USES PERMITTED
28 SINGLE FAMILY LOTS
II. BULK REGULATIONS
A. MINIMUM LOT AREA SHALL BE 6000 S.F.
B. MINIMUM LOT WIDTH SHALL BE 40 FEET
C. MINIMUM SETBACKS
1. FRONT: 40 FEET
2. REAR: 20 FEET
3. SIDE: 5 FEET
III. ACCESS AND CIRCULATION
DEXTER ROAD SHALL BE DEDICATED AND IMPROVED 57 FEET FROM CENTERLINE
IV. LANDSCAPING AND SCREENING
A. EVERGREEN SHRUBS SHALL BE PROVIDED ALONG THE FRONTAGE OF DEXTER
ROAD IN LIEU OF STREET TREES (DUE TO OHE)
B. EACH LOT SHALL HAVE A MINIMUM OF ONE STREET TREE PLANTED BY THE
BUILDING PERMIT HOLDER.
V. DRAINAGE
A. ALL DRAINAGE PLANS TO BE SUBMITTED TO CITY ENGINEER(S) FOR REVIEW.
B. AN OVERALL DRAINAGE PLAN FOR THE ENTIRE SITE SHALL BE SUBMITTED TO
THE CITY ENGINEER BEFORE ANY FINAL PLAN IS RECORDED.
C. DRAINAGE IMPROVEMENTS TO BE PROVIDED UNDER CONTRACT IN
ACCORDANCE WITH THE SUBDIVISION REGULATIONS, AND THE CITY OF
MEMPHIS DRAINAGE DESIGN MANUAL.
D. DESIGN OF THE STORM WATER CONVEYANCE AND MANAGEMENT FACILITIES
FOR THIS PROJECT SHALL BE IN ACCORDANCE WITH THE "CITY OF MEMPHIS
DRAINAGE DESIGN MANUAL". THE MANUAL REQUIRED ON- SITE DETENTION OF
STORMWATER RUN-OFF, GENERATED FROM THIS PROJECT, WHICH EXCEEDS THE
CAPACITY OF THE DOWN STREAM SYSTEM. DRAINAGE CALCULATIONS
PERFORMED IN ACCORDANCE WITH THE MANUAL SHALL BE SUBMITTED
VERIFYING THAT ADEQUATE NON-BUILDABLE AREAS HAVE BEEN PROVIDED FOR
STORM WATER DETENTION FACILITIES. FOR INFORMATION CONCERNING THIS
REQUIREMENT, PLEASE CONTACT THE CITY ENGINEER'S OFFICE.
E. THE FOLLOWING NOTE SHALL BE PLACED ON THE FINAL PLAT OF ANY
DEVELOPMENT REQUIRING ON-SITE STORM WATER DETENTION FACILITIES. THE
AREAS DENOTED BY "RESERVED FOR STORMWATER DETENTION" SHALL NOT BE
USED AS A BUILDING SITE OR FILLED WITHOUT FIRST OBTAINING PERM ISSION
FROM THE CITY OR COUNTY ENGINEER, AS APPLICABLE. THE STORMWATER
DETENTION SYSTEMS LOCATED IN THESE AREAS, EXCEPT FOR THOSE PART
LOCATED IN A PUBLIC DRAINAGE EASEMENT, SHALL BE OWNED AND
MAINTAINED BY THE PROPERTY OWNER AND/OR PROPERTY OWNERS'
ASSOCIATION. SUCH MAINTENANCE SHALL BE PERFORMED SO AS TO ENSURE
THAT THE SYSTEM OPERATES IN ACCORDANCE WITH THE APPROVED PLAN ON
FILE IN THE CITY/COUNTY ENGINEER'S OFFICE. SUCH MAINTENANCE SHALL
INCLUDE, BUT NO BE LIMITED TO REMOVAL OF SEDIMENTATION, FALLEN
OBJECTS, DEBRIS AND TRASH, MOWING, OUTLET CLEANING, AND REPAIR OF
DRAINAGE STRUCTURES.
VI. SITE PLAN REVIEW
A SITE PLAN SHALL BE SUBMITTED FOR REVIEW, COMMENT AND
RECOMMENDATION OF THE DIVISION OF PLANNING AND DEVELOPMENT (DPD)
VII. THE LAND USE CONTROL BOARD MAY MODIFY THE BUILDING SETBACK, BUILDING
HEIGHT, ACCESS, PARKING, LANDSCAPING AND SIGN REQUIREMENTS IF
EQUIVALENT ALTERNATIVES ARE PRESENTED.
VIII. A FINAL PLAN SHALL BE FILED WITHIN FIVE YEARS OF APPROVAL OF THE OUTLINE
PLAN. THE LAND USE CONTROL BOARD MAY GRANT EXTENSIONS AT THE REQUEST
OF THE APPLICANT.
IX. ANY FINAL PLAN SHALL INCLUDE THE FOLLOWING:
A. THE OUTLINE PLAN CONDITIONS
B. A STANDARD SUBDIVISION CONTRACT AS DEFINED BY THE SUBDIVISION
REGULATIONS FOR ANY NEEDED PUBLIC IMPROVEMENTS.
C. THE LOCATION AND OWNERSHIP, WHETHER PUBLIC OR PRIVATE, OF ANY
EASEMENT.
D. A STATEMENT CONVEYING ALL COMMON FACILITIES AND AREAS TO A
PROPERTY OWNER'S ASSOCIATION, OR OTHER ENTITY, FOR OWNERSHIP AND
MAINTENANCE PURPOSES.
E. THE FOLLOWING NOTE SHALL BE PLACED ON THE FINAL PLAT OF ANY
DEVELOPMENT REQUIRING ON-SITE STORMWATER DETENTION FACILITIES. THE
AREAS DENOTED BY "RESERVED FOR STORMWATER DETENTION" SHALL NOT BE
USED AS A BUILDING SITE OR FILLED WITHOUT FIRST OBTAINING WRITT EN
PERMISSION FROM THE CITY OR COUNTY ENGINEER, AS APPLICABLE. THE
STORMWATER DETENTION SYSTEMS LOCATED IN THESE AREAS, EXCEPT FOR
THOSE PARTS LOCATED IN A PUBLIC DRAINAGE EASEMENT, SHALL BE OWNED
AND MAINTAINED BY THE PROPERTY OWNER AND OR PROPER5TY OWNER S'
ASSOCIATION. SUCH MAINTENANCE SHALL BE PERFORMED SO AS TO ENSURE
THAT THE SYSTEM OPERATES IN ACCORDANCE WITH THE APPROVED PLAN ON
FILE IN THE4 CITY / COUNTY ENGINEER'S OFFICE. SUCH MAINTENANCE SHALL
INCLUDE, BUT NOT BE LIMITED TO REMOVAL OF SEDIMENTATION, FALLEN
OBJECTS, DEBRIS AND TRASH, MOWING, OUTLET CLEANING AND REPAIR OF
DRAINAGE STRUCTURES.
CONCEPT PLAN
ATTEST:
CC: Division of Planning and Development
– Land Use and Development Services
– Office of Construction Enforcement
Staff Writer: Nabanita Nira E-mail: nabanita.nira@memphistn.gov
AGENDA ITEM: 12 L.U.C.B. MEETING: November 13, 2025
CASE NUMBER: PD 2025-014
DEVELOPMENT: Dexter-Candle Ridge Planned Development
LOCATION: 7913 Dexter Rd
COUNCIL DISTRICT: District 2 and Super District 9
OWNER/APPLICANT: Providence Private Equity Group LLC
REPRESENTATIVE: David Gean Bray, The Bray Firm
REQUEST: 28-lot residential development
EXISTING ZONING: Conservation Agriculture (CA)
CONCLUSIONS
1. The applicant is requesting for approval of a +/ -6.0-acre residential planned development consisting of 28
single family residential lot. Previously the application was approved as part of a major modification to the
existing The Commons at Dexter Lake PD (known as MJR 21-038). It was later determined that the subject
parcel was not included in the PD boundaries.
2. The proposed development will consist of 28 lots of minimum 6,000 sq ft. There will be one access street
called Candle Ridge Cove South from Dexter Rd to the development. Each lot will have a front setback of
40 ft, side setback of 5 ft and rear setback of 20 ft.
3. Planned developments are intended as a tool to allow creative and imaginative design that will promote
amenities beyond those expected in conventional developments. The proposed planned development is in
alignment with the intent of the Unified Development Code in accordance with Section 4.10.1 as it will
allow creative and coordinated land use development.
4. The project will not have a substantial or undue adverse effect upon adjacent property, the character of
the neighborhood, traffic conditions, parking, utility facilities and other matters affecting the public health,
safety, and general welfare.
CONSISTENCY WITH MEMPHIS 3.0
This proposal is consistent with the Memphis 3.0 General Plan per the land use decision criteria. See further
analysis on pages 20-23 of this report.
RECOMMENDATION:
Approval with conditions
Staff Report November 13, 2025
PD 2025-014 Page 2
2
LOCATION MAP
Subject property located within the pink circle
SUBJECT PROPERTY
Staff Report November 13, 2025
PD 2025-014 Page 3
3
PUBLIC NOTICE VICINITY MAP
Subject property highlighted in yellow
PUBLIC NOTICE DETAILS
In accordance with Sub-Section 9.3.4A of the Unified Development Code, a notice of public hearing is required
to be mailed and signage posted . A total 129 notices were mailed on October 23, 2025 , see page 24 of this
report for a copy of said notice. Additionally, one sign was posted at the subject property, see page s 25-26 of
this report for a copy of the sign affidavit.
NEIGHBORHOOD MEETING
The meeting was held at 6:00 PM on Thursday October 30, 2025, at the Cordova Library, 8457 Trinity Road.
Staff Report November 13, 2025
PD 2025-014 Page 4
4
AERIAL
Subject property outlined in yellow, imagery from 2023
Staff Report November 13, 2025
PD 2025-014 Page 5
5
ZONING MAP
Subject property highlighted in yellow
Staff Report November 13, 2025
PD 2025-014 Page 6
6
LAND USE MAP
Subject property indicated by a pink star
Staff Report November 13, 2025
PD 2025-014 Page 7
7
SITE PHOTOS
View of subject property from Dexter Road looking southeast
View of subject property from Dexter Road looking southwest
Staff Report November 13, 2025
PD 2025-014 Page 8
8
PROPOSED OUTLINE PLAN
Staff Report November 13, 2025
PD 2025-014 Page 9
9
PROPOSED OUTLINE PLAN– MAGNIFIED
Staff Report November 13, 2025
PD 2025-014 Page 10
10
CASE REVIEW
Request
The request is a 28-lot residential development.
Applicability
Staff agrees the applicability standards and criteria as set out in Section 4.10.2 of the Unified Development Code
are or will be met.
4.10.2 Applicability
The governing bodies may, upon proper application, grant a special use permit for a planned development (see
Chapter 9.6) for a tract of any size within the City or for tracts of at least three acres in unincorporated Shelby
County to facilitate the use of flexible techniques of land development and site design, by providing relief from
district requirements designed for conventional developments, and may establish standards and procedures for
planned developments in order to obtain one or more of the following objectives:
A. Environmental design in the development of land that is of a higher quality than is possible under the
regulations otherwise applicable to the property.
B. Diversification in the uses permitted and variation in the relationship of uses, structures, open space and
height of structures in developments intended as cohesive, unified projects.
C. Functional and beneficial uses of open space areas.
D. Preservation of natural features of a development site.
E. Creation of a safe and desirable living environment for residential areas characterized by a unified
building and site development program.
F. Rational and economic development in relation to public services.
G. Efficient and effective traffic circulation, both within and adjacent to the development site, that supports
or enhances the approved transportation network.
H. Creation of a variety of housing compatible with surrounding neighborhoods to provide a greater choice
of types of environment and living units.
I. Revitalization of established commercial centers of integrated design to order to encourage the
rehabilitation of such centers in order to meet current market preferences.
J. Provision in attractive and appropriate locations for business and manufacturing uses in well -designed
buildings and provision of opportunities for employment closer to residence with a reduction in travel
time from home to work.
K. Consistency with the Memphis 3.0 General Plan.
General Provisions
Staff agrees the general provisions standards and criteria as set out in Section 4.10.3 of the Unified Development
Code are or will be met.
4.10.3 General Provisions
The governing bodies may grant a special use permit for a planned development which modifies the applicable
district regulations and other regulations of this development code upon written findings and recommendations
of the Land Use Control Board and the Zoning Administrator which shall be forwarded pursuant to provisions
contained in this Chapter.
A. The proposed development will not unduly injure or damage the use, value and enjoyment of surrounding
property nor unduly hinder or prevent the development of surrounding property in accordance with the
Staff Report November 13, 2025
PD 2025-014 Page 11
11
current development policies and plans of the City and County.
B. An approved water supply, community waste water treatment and disposal, and storm water drainage
facilities that are adequate to serve the proposed development have been or will be provided concurrent
with the development.
C. The location and arrangement of the structures, parking areas, walks, lighting and other service facilities
shall be compatible with the surrounding land uses, and any part of the proposed development not used
for structures, parking and loading areas or access way shall be landscaped or otherwise improved except
where natural features are such as to justify preservation.
D. Any modification of the district standards that would otherwise be applicable to the site are warranted
by the design of the outline plan and the amenities incorporated therein, and are not inconsistent with
the public interest.
E. Homeowners’ associations or some other responsible party shall be required to maintain any and all
common open space and/or common elements.
F. Lots of record are created with the recording of a planned development final plan.
Residential Criteria
Staff agrees the additional planned residential development criteria as set out in Section 4.10.4 of the Unified
Development Code are or will be met.
4.10.4 Planned Residential Developments
In addition to the standards and criteria set forth in Section 4.10.3, planned residential developments shall
comply with the standards and criteria set forth below:
A. Formal Open Space
A minimum of 0.6% of the total land area of a planned residential development of 15 acres or more
shall be subject to the formal open space requirements of Section 6.2.3. No open area may be
delineated or accepted as formal open space under the provisions of this Chapter unless it meets the
standards of Chapter 6.2, Open Space.
B. Accessibility of Site
All proposed streets, alleys and driveways shall be adequate to serve the residents, occupants, visitors
or other anticipated traffic of the planned residential development. The location of the entrance
points of the streets, alleys and driveways upon exis ting public roadways shall be subject to the
approval of the City or County Division of Public Works.
C. Off-Street Parking
Off-street parking shall be conveniently accessible to all dwelling units and other uses. Where
appropriate, common driveways, parking areas, walks and steps may be provided, maintained and
lighted for night use. Screening of parking and service areas shal l be required through use of trees,
shrubs and/or hedges and screening walls.
D. Pedestrian Circulation
The pedestrian circulation system and its related walkways shall be separated, whenever feasible,
from the vehicular street system in order to provide an appropriate degree of separation of pedestrian
and vehicular movement.
E. Privacy
The planned residential development shall provide reasonable visual and acoustical privacy for
dwelling units within and adjacent to the planned residential development. Protection and
enhancement of property and the privacy of its occupants may be provide d by the screening of
objectionable views or uses and reduction of noise through the use of fences, insulation, natural
Staff Report November 13, 2025
PD 2025-014 Page 12
12
foliage, berms and landscaped barriers. High -rise buildings shall be located within the development
in such a way as to minimize any adverse impact on adjoining low rise buildings.
F. Distance Requirements
Where minimum distance requirements are provided between single family residential zoning
districts and certain stipulated uses in this Code, the single -family residential areas of planned
developments shall be considered zoned residential.
Approval Criteria
Staff agrees the approval criteria as set out in Section 9.6.9 of the Unified Development Code are being met.
9.6.9 Approval Criteria
No special use permit or planned development shall be approved unless the following findings are made
concerning the application:
A. The project will not have a substantial or undue adverse effect upon adjacent property, the character of
the neighborhood, traffic conditions, parking, utility facilities and other matters affecting the public
health, safety, and general welfare.
B. The project will be constructed, arranged and operated so as to be compatible with the immediate vicinity
and not interfere with the development and use of adjacent property in accordance with the applicable
district regulations.
C. The project will be served adequately by essential public facilities and services such as streets, parking,
drainage, refuse disposal, fire protection and emergency services, water and sewers; or that the applicant
will provide adequately for such services.
D. The project will not result in the destruction, loss or damage of any feature determined by the governing
bodies to be of significant natural, scenic or historic importance.
E. The project complies with all additional standards imposed on it by any particular provisions authorizing
such use.
F. The request will not adversely affect any plans to be considered (see Chapter 1.9), or violate the character
of existing standards for development of the adjacent properties.
G. The governing bodies may impose conditions to minimize adverse effects on the neighborhood or on
public facilities, and to ensure compatibility of the proposed development with surrounding properties,
uses, and the purpose and intent of this development code.
H. Any decision to deny a special use permit request to place, construct, or modify personal wireless service
facilities shall be in writing and supported by substantial evidence contained in a written record, per the
Telecommunications Act of 1996, 47 USC 332(c)(7)(B)(iii). The review body may not take into account any
environmental or health concerns.
Site Details
Address:
7913 Dexter Rd
Parcel ID:
096500 00189
Area:
+/-6 acres
Description:
Staff Report November 13, 2025
PD 2025-014 Page 13
13
The subject property is known as Outparcel C of The Commons at Dexter Lake PD (PD 95 -374 CC) with an
underlying zoning of Conservation Agriculture (CA) for any regulation not stated within the PD. Per the
Assessor’s website the subject property is vacant, and the previous house was demolished in 2021 (known as
DEM-21-000296). The lot has one street frontage from Dexter Road.
Site Zoning History
On August 3, 1977, the Board of Adjustment rejected an application to allow the extraction and processing of
sand and gravel Docket BOA 1977-120 on a tract that include a portion of the subject property.
The Outline Plan for The Commons at Dexter Lake P.D. known as PD 95 -374 CC (formerly PD 87 -379 CC) was
recorded in 1996 where the subject property is designated as Outparcel C. However, the subject property was
not part of the approved planned development.
On October 14, 2021, the Land Use Control Board approved a major modification application known as MJR 21-
038 (CORRES PD 95-374 CC) formerly known as PD 2021-035 to allow 28-lot single family residential subdivision
on the subject property. It was later determined that the subject parcel was not included in the PD boundaries,
therefore, this case is seeking to complete the approval process.
Outline Plan Review
• The proposed outline plan shows 28 lots of minimum 6,000 sq ft.
• 40 ft front setback, 5 ft side setback and 20 ft rear setback.
• 17,534 sq ft COS A reserved for detention / private sewer.
• One access street called Candle Ridge Cove South from Dexter Rd.
Analysis
The applicant is requesting for approval of a +/-6.0-acre residential planned development consisting of 28 single
family residential lot. Previously the application was approved as part of a major modification to the existing
The Commons at Dexter Lake PD (known as MJR 21 -038). It was later determined that the subject parcel was
not included in the PD boundaries.
The proposed development will consist of 28 lots of minimum 6,000 sq ft. There will be one access street called
Candle Ridge Cove South from Dexter Rd to the development. Each lot will have a front setback of 40 ft, side
setback of 5 ft and rear setback of 20 ft.
Planned developments are intended as a tool to allow creative and imaginative design that will promote
amenities beyond those expected in conventional developments. The proposed planned development is in
alignment with the intent of the Unified Development Code in accordance with Section 4.10.1 as it will allow
creative and coordinated land use development. Also, this proposal is consistent with the Memphis 3.0 General
Plan.
The project will not have a substantial or undue adverse effect upon adjacent property, the character of the
neighborhood, traffic conditions, parking, utility facilities and other matters affecting the public health, safety,
and general welfare.
Staff Report November 13, 2025
PD 2025-014 Page 14
14
RECOMMENDATION
Staff recommends approval with outline plan conditions.
Outline Plan Conditions
DEXTER - CANDLE RIDGE PLANNED DEVELOPMENT
I. USES PERMITTED
28 SINGLE FAMILY LOTS
II. BULK REGULATIONS
A. MINIMUM LOT AREA SHALL BE 6000 S.F.
B. MINIMUM LOT WIDTH SHALL BE 40 FEET
C. MINIMUM SETBACKS
1. FRONT: 40 FEET
2. REAR: 20 FEET
3. SIDE: 5 FEET
III. ACCESS AND CIRCULATION
DEXTER ROAD SHALL BE DEDICATED AND IMPROVED 57 FEET FROM CENTERLINE
IV. LANDSCAPING AND SCREENING
A. EVERGREEN SHRUBS SHALL BE PROVIDED ALONG THE FRONTAGE OF DEXTER ROAD IN LIEU OF STREET
TREES (DUE TO OHE)
B. EACH LOT SHALL HAVE A MINIMUM OF ONE STREET TREE PLANTED BY THE BUILDING PERMIT HOLDER.
V. DRAINAGE
A. ALL DRAINAGE PLANS TO BE SUBMITTED TO CITY ENGINEER(S) FOR REVIEW.
B. AN OVERALL DRAINAGE PLAN FOR THE ENTIRE SITE SHALL BE SUBMITTED TO THE CITY ENGINEER
BEFORE ANY FINAL PLAN IS RECORDED.
C. DRAINAGE IMPROVEMENTS TO BE PROVIDED UNDER CONTRACT IN ACCORDANCE WITH THE
SUBDIVISION REGULATIONS, AND THE CITY OF MEMPHIS DRAINAGE DESIGN MANUAL.
D. DESIGN OF THE STORM WATER CONVEYANCE AND MANAGEMENT FACILITIES FOR THIS PROJECT
SHALL BE IN ACCORDANCE WITH THE "CITY OF MEMPHIS DRAINAGE DESIGN MANUAL". THE MANUAL
REQUIRED ON-SITE DETENTION OF STORMWATER RUN-OFF, GENERATED FROM THIS PROJECT, WHICH
EXCEEDS THE CAPACITY OF THE DOWN STREAM SYSTEM. DRAINAGE CALCULATIONS PERFORMED IN
ACCORDANCE WITH THE MANUAL SHALL BE SUBMITTED VERIFYING THAT ADEQUATE NON-BUILDABLE
AREAS HAVE BEEN PROVIDED FOR STORM WATER DETENTION FACILITIES. FOR INFORMATION
CONCERNING THIS REQUIREMENT, PLEASE CONTACT THE CITY ENGINEER'S OFFICE.
E. THE FOLLOWING NOTE SHALL BE PLACED ON THE FINAL PLAT OF ANY DEVELOPMENT REQUIRING ON-
SITE STORM WATER DETENTION FACILITIES. THE AREAS DENOTED BY "RESERVED FOR STORMWATER
DETENTION" SHALL NOT BE USED AS A BUILDING SITE OR FILLED WITHOUT FIRST OBTAINING
PERMISSION FROM THE CITY OR COUNTY ENGINEER, AS APPLICABLE. THE STORMWATER DETENTION
SYSTEMS LOCATED IN THESE AREAS, EXCEPT FOR THOSE PART LOCATED IN A PUBLIC DRAINAGE
EASEMENT, SHALL BE OWNED AND MAINTAINED BY THE PROPERTY OWNER AND/OR PROPERTY
Staff Report November 13, 2025
PD 2025-014 Page 15
15
OWNERS' ASSOCIATION. SUCH MAINTENANCE SHALL BE PERFORMED SO AS TO ENSURE THAT THE
SYSTEM OPERATES IN ACCORDANCE WITH THE APPROVED PLAN ON FILE IN THE CITY/COUNTY
ENGINEER'S OFFICE. SUCH MAINTENANCE SHALL INCLUDE, BUT NO BE LIMITED TO REMOVAL OF
SEDIMENTATION, FALLEN OBJECTS, DEBRIS AND TRASH, MOWING, OUTLET CLEANING, AND REPAIR
OF DRAINAGE STRUCTURES.
VI. SITE PLAN REVIEW
A SITE PLAN SHALL BE SUBMITTED FOR REVIEW, COMMENT AND RECOMMENDATION OF THE DIVISION
OF PLANNING AND DEVELOPMENT (DPD)
VII. THE LAND USE CONTROL BOARD MAY MODIFY THE BUILDING SETBACK, BUILDING HEIGHT, ACCESS,
PARKING, LANDSCAPING AND SIGN REQUIREMENTS IF EQUIVALENT ALTERNATIVES ARE PRESENTED.
VIII. A FINAL PLAN SHALL BE FILED WITHIN FIVE YEARS OF APPROVAL OF THE OUTLINE PLAN. THE LAND USE
CONTROL BOARD MAY GRANT EXTENSIONS AT THE REQUEST OF THE APPLICANT.
IX. ANY FINAL PLAN SHALL INCLUDE THE FOLLOWING:
A. THE OUTLINE PLAN CONDITIONS
B. A STANDARD SUBDIVISION CONTRACT AS DEFINED BY THE SUBDIVISION REGULATIONS FOR ANY
NEEDED PUBLIC IMPROVEMENTS.
C. THE LOCATION AND OWNERSHIP, WHETHER PUBLIC OR PRIVATE, OF ANY EASEMENT.
D. A STATEMENT CONVEYING ALL COMMON FACILITIES AND AREAS TO A PROPERTY OWNER'S
ASSOCIATION, OR OTHER ENTITY, FOR OWNERSHIP AND MAINTENANCE PURPOSES.
E. THE FOLLOWING NOTE SHALL BE PLACED ON THE FINAL PLAT OF ANY DEVELOPMENT REQUIRING ON-
SITE STORMWATER DETENTION FACILITIES. THE AREAS DENOTED BY "RESERVED FOR STORMWATER
DETENTION" SHALL NOT BE USED AS A BUILDING SITE OR FILLED WITHOUT FIRST OBTAINING WRITTEN
PERMISSION FROM THE CITY OR COUNTY ENGINEER, AS APPLICABLE. THE STORMWATER DETENTION
SYSTEMS LOCATED IN THESE AREAS, EXCEPT FOR THOSE PARTS LOCATED IN A PUBLIC DRAINAGE
EASEMENT, SHALL BE OWNED AND MAINTAINED BY THE PROPERTY OWNER AND OR PROPER5TY
OWNERS' ASSOCIATION. SUCH MAINTENANCE SHALL BE PERFORMED SO AS TO ENSURE THAT THE
SYSTEM OPERATES IN ACCORDANCE WITH THE APPROVED PLAN ON FILE IN THE4 CITY / COUNTY
ENGINEER'S OFFICE. SUCH MAINTENANCE SHALL INCLUDE, BUT NOT BE LIMITED TO REMOVAL OF
SEDIMENTATION, FALLEN OBJECTS, DEBRIS AND TRASH, MOWING, OUTLET CLEANING AND REPAIR OF
DRAINAGE STRUCTURES.
Staff Report November 13, 2025
PD 2025-014 Page 16
16
DEPARTMENTAL COMMENTS
The following comments were provided by agencies to which this application was referred:
City Engineer: See pages 17-18 of this report.
City Fire Division: See page 19 of this report.
City Real Estate: No comments received.
County Health Department: No comments received.
Shelby County Schools: No comments received.
Construction Code Enforcement: No comments received.
Memphis Light, Gas and Water: No comments received.
Office of Sustainability and Resilience: No comments received.
Office of Comprehensive Planning: See pages 20-23 of this report.
Staff Report November 13, 2025
PD 2025-014 Page 17
17
CITY ENGINEER COMMENTS
Staff Report November 13, 2025
PD 2025-014 Page 18
18
Staff Report November 13, 2025
PD 2025-014 Page 19
19
CITY FIRE DIVISION COMMENTS
DIVISION OF FIRE SERVICES ❖ FIRE PREVENTION BUREAU
2668 Avery Avenue Memphis Tennessee 38112
(901) 636-5401 Fax (901) 320-5425
Case Number: PD 2025 014
Date Reviewed: 11/7/25
Reviewed by: J. Stinson
Address or Site Reference: Dexter / Chickering
• Fire apparatus access shall comply with section 503.
• Where security gates are installed that affect required fire apparatus access roads, they shall comply with
section 503.6 (as amended).
• Fire protection water supplies (including fire hydrants) shall comply with section 507.
• Where fire apparatus access roads or a water supply for fire protection are required to be installed, such
protection shall be installed and made serviceable prior to and during the time of construction except when
approved alternate methods of protection are provided.
Staff Report November 13, 2025
PD 2025-014 Page 20
20
OFFICE OF COMPREHENSIVE PLANNING COMMENTS
Comprehensive Planning Review of Memphis 3.0 Consistency
This summary is being produced in response to the following application to support the Land Use and Development
Services department in their recommendation: PD 2025-014
Site Address/Location: 7913 Dexter Road
Overlay District/Historic District/Flood Zone: Not in an Overlay District, Historic District, or Flood Zone
Future Land Use Designation: Anchor Neighborhood-Mix of Building Types (AN-M)
Street Type: Avenue
Applicant is filing a new PD to develop a new single-family cul-de-sac subdivision.
The following information about the land use designation can be found on pages 76 – 122:
1. Future Land Use Planning Map
Red polygon indicates the application site on the Future Land Use Map.
2. Land Use Description/Intent
Anchor Neighborhood-Mix of Building Types (AN-M) are walkable neighborhoods
within a 5 – 10-minute walk of a Community Anchor. These neighborhoods are made
up of a mix of single-unit and multi-unit housing. Graphic portrayal of AN-M is to the
right.
Staff Report November 13, 2025
PD 2025-014 Page 21
21
“AN-M” Form & Location Characteristics
NURTURE/SUSTAIN - Primarily detached, single -family residences. Attached single -family, duplexes, triplexes and
quadplexes permitted on parcels within 100 feet of an anchor and at intersections where the presence of such housing
type currently exists; Other housing and commercial types along avenues, boulevards and parkways as identi fied in the
Street Types Map where same types exist on two or more adjacent parcels. Height: 1-3 stories. Scale: house-scale.
ACCELERATE: Primarily detached, single -family house-scale residences of 1 -3 stories in height. Attached, house -scale
single-family, duplexes, triplexes and quadplexes of 1-3 stories in height permitted on parcels within 200 feet of an anchor
and at intersections where the presence of such housing type currently exists. Building-scale large homes and apartments
of 2-4 stories in height permitted on parcels within 100 feet of an anchor; at intersections where the presence of such
housing type currently exist s at the intersection. Other housing and commercial types along avenues, boulevards and
parkways as identified in the Street Types Map where same types exist on one or more adjacent parcels.
“AN-M” Zoning Notes
Generally compatible with the following zone districts: RU-2, RU-3, RU-4, R-SD, R-R, MDR, and CMU-1 when located
along avenues, boulevards, and parkways as identified in the Street Types Map, in accordance with Form and
characteristics listed above.
Existing, Adjacent Land Use and Zoning
Existing Land Use and Zoning: Single-Family Residential; CA
Adjacent Land Use and Zoning: Single-family, Multi-family, Commercial, Vacant; CA, R-8, CMU-2.
Overall Compatibility: The requested use is compatible with the land use description/intent, form & location
characteristics, zoning notes, and existing, adjacent land use; but is not compatible with existing zoning. Current CA
Zoning does not allow for Single-Family subdivisions, but the surrounding uses are similar to the requested development.
Although, Anchor Neighborhoods and cul-de-sacs are inherently incompatible due to the disconnection between cul-de-
sacs and surrounding uses. While the form of the building types are consistent, the overall development pattern is not
compatible.
Staff Report November 13, 2025
PD 2025-014 Page 22
22
3. Degree of Change Map
Red polygon denotes the proposed site in Degree of Change area. There Degree of Change is
Sustain.
4. Degree of Change Description
Sustain areas rely on limited public support and private resources to maintain the existing pattern of a place.
The proposed development is a private investment that is contextually compatible with the surrounding suburban
development types.
5. Objectives/Actions Consistent with Goal 1, Complete, Cohesive, Communities
The requested use is consistent with Objective 1.1 - Focus future growth and density in and around Community and
Citywide Anchors Action 1.1.31 - Increase infill and redevelopment that locate residential, employment, and retail
uses near each other to maximize transit and active transportation AND Action 1.5.1 - Focus residential infill efforts
in anchor neighborhoods to support anchors and neighborhood commercial districts with appropriate population
density. The location of a new residential subdivision to an anchor helps to increase density near a mix of uses and
supports the existing commercial development nearby.
6. Pertinent Sections of Memphis 3.0 that Address Land Use Recommendations
The proposed development is inconsistent with Objective 4.2 - Promote safe movement of people and vehicles
across all modes of travel Action 4.2.3 - Consider multimodal level of service when designing streets for pedestrian
and bicycle use. Cul-de-sacs do not support multi-modal travel and instead support auo-oriented travel by way of
separating and funneling traffic through a single-entrance on a roadway. This increases car traffic in the
Staff Report November 13, 2025
PD 2025-014 Page 23
23
development’s one connection to a major road which makes bike and pedestrian travel more dangerous. More
effort should be placed towards connecting the development to the nearby anchor area in a way that supports
multi-modal and active transit.
Consistency Analysis Summary
Applicant is filing a new PD to develop a new single-family cul-de-sac subdivision.
The requested use is compatible with the land use description/intent, form & location characteristics, zoning notes, and
existing, adjacent land use; but is not compatible with existing zoning. Current CA Zoning does not allow for Single-Family
subdivisions, but the surrounding uses are similar to the requested development. Although, Anchor Neighborhoods and
cul-de-sacs are inherently incompatible due to the disconnection between cul-de-sacs and surrounding uses. While the
form of the building types are consistent, the overall development pattern is not compatible.
The proposed development is a private investment that is contextually compatible with the surrounding suburban
development types.
The requested use is consistent with Objective 1.1 - Focus future growth and density in and around Community and
Citywide Anchors Action 1.1.31 - Increase infill and redevelopment that locate residential, employment, and retail uses
near each other to maximize transit and active transportation AND Action 1.5.1 - Focus residential infill efforts in anchor
neighborhoods to support anchors and neighborhood commercial districts with appropriate population density.
The proposed development is inconsistent with Objective 4.2 - Promote safe movement of people and vehicles across all
modes of travel Action 4.2.3 - Consider multimodal level of service when designing streets for pedestrian and bicycle use.
While the proposed use is consistent with Memphis 3.0, the form of the development does not support better
connectivity for all modes of transportation. If possible, more consideration should be given to better connecting the
development to the nearby anchor. Still, the development type is consistent with the more suburban form of nearby
development and helps to sustain the current activity within the Dexter Road and Germantown Pkwy anchor.
Based on the information provided, the proposal is CONSISTENT with the Memphis 3.0 Comprehensive Plan.
Summary Compiled by: Grayson Vincent, Comprehensive Planning.
Staff Report November 13, 2025
PD 2025-014 Page 24
24
MAILED PUBLIC NOTICE
Staff Report November 13, 2025
PD 2025-014 Page 25
25
SIGN AFFIDAVIT
Staff Report November 13, 2025
PD 2025-014 Page 26
26
Staff Report November 13, 2025
PD 2025-014 Page 27
27
APPLICATION
Staff Report November 13, 2025
PD 2025-014 Page 28
28
Staff Report November 13, 2025
PD 2025-014 Page 29
29
Staff Report November 13, 2025
PD 2025-014 Page 30
30
OWNER AFFIDAVIT
Staff Report November 13, 2025
PD 2025-014 Page 31
31
LETTER OF INTENT
Staff Report November 13, 2025
PD 2025-014 Page 32
32
LETTERS RECEIVED
One letter was received at the time of completion of this report and have subsequently been attached.
Staff Report November 13, 2025
PD 2025-014 Page 33
33
East Service Center: 6465 Mullins Station Rd; Memphis,
Tennessee
38134
Downtown Service Center: 125 N. Main Street;
Memphis, T
ennessee 38103
website: www.develop901.com
Memphis and Shelby County Division of
Planning and Development
Record Summary for Planned Development
Record Detail Information
Record T
ype: Planned Development Record Status: Pending
Opened Date:
October 14, 2025
Record Number: PD 2025-014
Record Name: Dexter-Candle Ridge Planned Development
Expiration Date:
Description of Work: 28 single family lots in the CA zoning district
Parent Record Number:
Address:
7913 DEXTER RD, Cordova 38016
Owner Information
Primary Owner Name
Owner
Address Owner Phone
Y PROVIDENCE PRIVA
TE EQUITY GROUP LLC
6744 STRNAWAY DR, MEMPHIS, TN 38119
Parcel Information
096500 00189
Data Fields
PREAPPLICA
TION MEETING
Name of DPD Planner Brett Ragsdale
Date of Meeting 10/10/2025
Pre-application Meeting
Type Phone
GENERAL PROJECT INFORMATION
Planned Development Type New Planned Development (PD)
Previous Docket / Case Number -
Medical Overlay / Uptown No
If this development is located in unincorporated
Shelby County, is the tract at least three acres?
(Note a tract of less than three acres is not
yes
Page 1 of 3 PD 2025-014
GENERAL PROJECT INFORMATION
eligible for a planned development in
unincorporated Shelby County)
Is this application in response to a citation, stop
work order, or zoning letter
No
If yes, please provide a copy of the citation, stop
work order, and/or zoning letter along with any
other relevant information
n/a
APPROVAL CRITERIA
UDC Sub-Section 9.6.9A The project was previously approved erroneously as
an amendment to an existing PD. The proposed
uses are compatible with surrounding uses
UDC Sub-Section 9.6.9B This project is compatible with surrounding uses.
UDC Sub-Section 9.6.9C Y
es
UDC Sub-Section 9.6.9D Agreed
UDC Sub-Section 9.6.9E Agreed
UDC Sub-Section 9.6.9F Agreed
GENERAL PROVISIONS
UDC Sub-Section 4.10.3A Agreed
B) An approved water supply, community waste
water treatment and disposal, and storm water
drainage facilities that are adequate to serve the
proposed development have been or will be
provided concurrent with the development
Agreed
C) The location and arrangement of the
structures, parking and loading areas, walks,
lighting and other service facilities shall be
compatible with the surrounding land uses, and
any part of the proposed development not used
for such facilities shall be landscaped or
otherwise improved except where natural
features are such as to justify preservation
Agreed
D) Any modification of the district standards that
would otherwise be applicable to the site are
warranted by the design of the outline plan and
the amenities incorporated therein, and are not
inconsistent with the public interest
Agreed
E) Homeowners’ associations or some other
responsible party shall be required to maintain
any and all common open space and/or common
elements
Agreed
F) Lots of record are created with the recording
of a planned development final plan
Agreed
GIS INFORMATION
Case Layer BOA1977-120, BOA1963-040-CO
Central Business Improvement District No
Class R
Downtown Fire District No
Page 2 of 3 PD 2025-014
GIS INFORMATION
Historic District -
Land Use V
ACANT
Municipality MEMPHIS
Overlay/Special Purpose District Fletcher Creek Overlay
Zoning CA
State Route -
Lot -
Subdivision PT COMMON A
T DEXTER LAKE PD OUTLINE
PLAN
Planned Development District -
Wellhead Protection Overlay District No
County Commission District -
City Council District -
City Council Super District -
Contact Information
PROVIDENCE PRIVA
TE EQUITY GROUP LLC
6744 STRNAWA
Y DR, MEMPHIS, TN, MEMPHIS, TN, 38119
-
APPLICANT
Name
Address
Phone
Contact Type
THE BRAY
FIRM
2950 STAGE PLAZA NOR
TH,
(901)487-2425
ARCHITECT / ENGINEER /
SURVEYOR
Name
Address
Phone
Contact Type
Fee Information
Date
AssessedBalanceStatusFeesQuantityFee ItemInvoice #
10/14/20250.00INVOICED0.001Credit Card Use Fee (.026
x fee)
1684494
Total Fee Invoiced
: $0.00 Total Balance: $0.00
Page 3 of 3 PD 2025-014
.
.
LAND USE AND DEVELOPMENT SERVICES CERTIFICATE
THIS FINAL PLAT CONFORMS WITH THE PLANNED DEVELOPMENT ACTED ON BY THE
LAND USE CONTROL BOARD ON (DATE) AND APPROVED BY THE COUNCIL OF THE
CITY OF MEMPHIS ON (DATE).
BY_____________________________________ DATE____________
ZONING ADMINISTRATOR
LUDS_______________________ DATE_______________
CITY/COUNTY ENGINEER_____________________________ DATE____________
DEXTER - CANDLE RIDGE PLANNED DEVELOPMENT
I. USES PERMITTED
28 SINGLE FAMILY LOTS
II. BULK REGULATIONS
A. MINIMUM LOT AREA SHALL BE 6000 S.F.
B. MINIMUM LOT WIDTH SHALL BE 40 FEET
C. MINIMUM SETBACKS
1. FRONT: 40 FEET
2. REAR: 20 FEET
3. SIDE: 5 FEET
III. ACCESS AND CIRCULATION
DEXTER ROAD SHALL BE DEDICATED AND IMPROVED 57 FEET FROM CENTERLINE
IV. LANDSCAPING AND SCREENING
1. EVERGREEN SHRUBS SHALL BE PROVIDED ALONG THE FRONTAGE OF DEXTER ROAD IN LIEU OF STREET TREES (DUE TO OHE)
2. EACH LOT SHALL HAVE ONE STREET TREE PLANTED BY THE BUILDING PERMIT HOLDER.
3. EACH LOT SHALL HAVE ONE REAR YARD TREE PLANTED BY THE BUILDING PERMIT HOLDER.
V. DRAINAGE
A. ALL DRAINAGE PLANS TO BE SUBMITTED TO CITY ENGINEER(S) FOR REVIEW.
B. AN OVERALL DRAINAGE PLAN FOR THE ENTIRE SITE SHALL BE SUBMITTED TO THE CITY ENGINEER BEFORE ANY FINAL PLAN IS RECORDED.
C. DRAINAGE IMPROVEMENTS TO BE PROVIDED UNDER CONTRACT IN ACCORDANCE WITH THE SUBDIVISION REGULATIONS, AND THE CITY OF MEMPHIS DRAINAGE DESIGN MANUAL.
D. DESIGN OF THE STORM WATER CONVEYANCE AND MANAGEMENT FACILITIES FOR THIS PROJECT SHALL BE IN ACCORDANCE WITH THE "CITY OF MEMPHIS DRAINAGE DESIGN MANUAL". THE MANUAL REQUIRED
ON-SITE DETENTION OF STORMWATER RUN-OFF, GENERATED FROM THIS PROJECT, WHICH EXCEEDS THE CAPACITY OF THE DOWN STREAM SYSTEM. DRAINAGE CALCULATIONS PERFORMED IN ACCORDANCE
WITH THE MANUAL SHALL BE SUBMITTED VERIFYING THAT ADEQUATE NON-BUILDABLE AREAS HAVE BEEN PROVIDED FOR STORM WATER DETENTION FACILITIES. FOR INFORMATION CONCERNING THIS
REQUIREMENT, PLEASE CONTACT THE CITY ENGINEER'S OFFICE.
E. THE FOLLOWING NOTE SHALL BE PLACED ON THE FINAL PLAT OF ANY DEVELOPMENT REQUIRING ON-SITE STORM WATER DETENTION FACILITIES. THE AREAS DENOTED BY "RESERVED FOR STORMWATER
DETENTION" SHALL NOT BE USED AS A BUILDING SITE OR FILLED WITHOUT FIRST OBTAINING PERMISSION FROM THE CITY OR COUNTY ENGINEER, AS APPLICABLE. THE STORMWATER DETENTION SYSTEMS
LOCATED IN THESE AREAS, EXCEPT FOR THOSE PART LOCATED IN A PUBLIC DRAINAGE EASEMENT, SHALL BE OWNED AND MAINTAINED BY THE PROPERTY OWNER AND/OR PROPERTY OWNERS' ASSOCIATION.
SUCH MAINTENANCE SHALL BE PERFORMED SO AS TO ENSURE THAT THE SYSTEM OPERATES IN ACCORDANCE WITH THE APPROVED PLAN ON FILE IN THE CITY/COUNTY ENGINEER'S OFFICE. SUCH MAINTENANCE
SHALL INCLUDE, BUT NO BE LIMITED TO REMOVAL OF SEDIMENTATION, FALLEN OBJECTS, DEBRIS AND TRASH, MOWING, OUTLET CLEANING, AND REPAIR OF DRAINAGE STRUCTURES.
VII. SITE PLAN REVIEW
A SITE PLAN SHALL BE SUBMITTED FOR REVIEW, COMMENT AND RECOMMENDATION OF THE OFFICE OF PLANNING AND DEVELOPMENT (OPD)
VIII. THE LAND USE CONTROL BOARD MAY MODIFY THE BUILDING SETBACK, BUILDING HEIGHT, ACCESS, PARKING, LANDSCAPING AND SIGN REQUIREMENTS IF EQUIVALENT ALTERNATIVES ARE PRESENTED.
IX. A FINAL PLAN SHALL BE FILED WITHIN FIVE YEARS OF APPROVAL OF THE OUTLINE PLAN. THE LAND USE CONTROL BOARD MAY GRANT EXTENSIONS AT THE REQUEST OF THE APPLICANT.
X. ANY FINAL PLAN SHALL INCLUDE THE FOLLOWING:
A. THE OUTLINE PLAN CONDITIONS
B. A STANDARD SUBDIVISION CONTRACT AS DEFINED BY THE SUBDIVISION REGULATIONS FOR ANY NEEDED PUBLIC IMPROVEMENTS.
C. THE LOCATION AND OWNERSHIP, WHETHER PUBLIC OR PRIVATE, OF ANY EASEMENT.
D. A STATEMENT CONVEYING ALL COMMON FACILITIES AND AREAS TO A PROPERTY OWNER'S ASSOCIATION, OR OTHER ENTITY, FOR OWNERSHIP AND MAINTENANCE PURPOSES.
E. THE FOLLOWING NOTE SHALL BE PLACED ON THE FINAL PLAT OF ANY DEVELOPMENT REQUIRING ON-SITE STORMWATER DETENTION FACILITIES. THE AREAS DENOTED BY "RESERVED FOR STORMWATER
DETENTION" SHALL NOT BE USED AS A BUILDING SITE OR FILLED WITHOUT FIRST OBTAINING WRITTEN PERMISSION FROM THE CITY OR COUNTY ENGINEER, AS APPLICABLE. THE STORMWATER DETENTION
SYSTEMS LOCATED IN THESE AREAS, EXCEPT FOR THOSE PARTS LOCATED IN A PUBLIC DRAINAGE EASEMENT, SHALL BE OWNED AND MAINTAINED BY THE PROPERTY OWNER AND OR PROPER5TY OWNERS'
ASSOCIATION. SUCH MAINTENANCE SHALL BE PERFORMED SO AS TO ENSURE THAT THE SYSTEM OPERATES IN ACCORDANCE WITH THE APPROVED PLAN ON FILE IN THE4 CITY / COUNTY ENGINEER'S OFFICE.
SUCH MAINTENANCE SHALL INCLUDE, BUT NOT BE LIMITED TO REMOVAL OF SEDIMENTATION, FALLEN OBJECTS, DEBRIS AND TRASH, MOWING, OUTLET CLEANING AND REPAIR OF DRAINAGE STRUCTURES.
SYMQTYCommon Name Botanical NameSizeSpacingRemarks
Trees
OH 22 Oakleaf HollyIlex x 'Conaf'5-6' H 12' o.c. Full to ground
FP 30 Forest Pansy RedbudCercis canadensis 'Forest Pansy'n/a 2" Cal.Uniform
TYPICAL PLANTING DETAILS
N.T.S.
SCORE SIDES OFPLANTING PITPLANTING SOIL MIXTURE1/3 EXISTING TOPOSIL,1/3 PEAT MOSS, 1/3 SANDOR OTHER APPROVED.
3" SHREDDED HARDWOODBARK. MULCH SHALL NOTTOUCH BASE OF TREETRUNK.PLANTING SOIL MIXTURE1/3 EXISTING TOPOSIL,1/3 PEAT MOSS, 1/3 SANDOR OTHER APPROVED. METAL T-POST STAKES,MININMUM 6-FOOT LENGTH.PLACE OUTSIDE ROOT BALLAND DRIVE INTOUNDISTURBED SOILMINIMUM OF 18 INCHES.MINIMUM 1 STAKES REQ'DPER STEM.TURN BACK TOP 2/3 OF BURLAPAND REMOVE SYNTHETIC WRAPCOMPLETELY. CUT WIRE OR TWINEAWAY FROM TRUNK
SHREDDED BARK MULCH 3"MIN. DEPTH - KEEP CLEARMINIMUM 2 INCHES FROMTRUNK. TURN BACK TOP 1/3 OF BURLAPAND REMOVE SYNTHETIC WRAPCOMPLETELY. CUT WIRE ORTWINE AWAY FROM TRUNK
METAL T-POSTSTAKES, MININMUM6-FOOT LENGTH.PLACE OUTSIDE ROOTBALL AND DRIVE INTOUNDISTURBED SOILMINIMUM OF 18 INCHES.MINIMUM 2 STAKESREQ'D PER TREE.STAKE COLOR: DARKGREEN
THEREAFTER AS NECESSARY TO
MAINTAIN THEM IN A HEALTHY &
AFTER PLANTING & AS OFTEN
THOROUGHLY WATER ALL MATERIAL
NOTE: TIES TO BE REMOVED IN
ONE YEAR.
VIGOROUS STATE
Shrubs
The Bray Firm
Telephone 901-383-8668
295
0 Stage Plaza North
Bartlett, Tennessee 38134
October 14, 2025
Brett Ragsdale
Memphis and Shelby County
Division of Planning and Development
125 North Main Street
Memphis, Tennessee 38103
RE: Dexter-Candle Ridge Planned Development
6.00 acres
Cordova, Tennessee
Mr. Ragsdale;
Please find attached the above referenced application for approval of a 6.0 acre planned
development consisting of 28 single family residences. This application was previously
approved as part of an amendment to the existing Commons at Dexter Lake PD but that
amendment was erroneously processed. This application seeks to make this development a new
planned development.
Thank you for considering this request. If you have any questions or need any additional
information, please feel free to call.
Sincerely,
David Gean Bray, P.E.
City Hall – 125 N. Main Street, Suite 468 – Memphis, Tennessee 38103 – (901) 636-6619
November 14, 2025
David Gean Bray
The Bray Firm
2950 Stage Plaza North
Bartlett, TN 38134
Sent via electronic mail to: dgbray@comcast.net & ac@cerpaconstruction.com
Dexter-Candle Ridge Planned Development
Case Number: PD 2025-014
LUCB Recommendation: Approval with outline plan conditions
Dear applicant,
On Thursday, November 13, 20 25, t he Memphis and Shelby County Land Use Control Board
recommended approval of your planned development application for the Dexter-Candle Ridge
Planned Development, subject to the attached outline plan conditions.
This application will be forwarded, for final action, to the Council of the City of Memphis. The Council
will review your application in a committee meeting prior to voting on it in a public hearing. The
applicant or the applicant’s representative(s) shall be in attendance at all meetings and hearings.
It is the applicant’s responsibility to contact the City Council Records Office to determine when the
application is scheduled to be heard at co mmittee and in public session. The City Council Records
Office may be reached at (901) 636-6792.
If for some reason you choose to withdraw your application, a letter should be mailed to the Land
Use and Development Services Department of the Division of Planning and Development at the
address provided above or emailed to the address provided below.
If you have questions regarding this matter, please feel free to contact me at (901) 636-6619 or via
email at nabanita.nira@memphistn.gov.
Respectfully,
Nabanita Nira
Planner II
Land Use and Development Services
Division of Planning and Development
File
Letter to Applicant
PD 2025-014
Page 2 of 3
Outline Plan Conditions
DEXTER - CANDLE RIDGE PLANNED DEVELOPMENT
I. USES PERMITTED
28 SINGLE FAMILY LOTS
II. BULK REGULATIONS
A. MINIMUM LOT AREA SHALL BE 6000 S.F.
B. MINIMUM LOT WIDTH SHALL BE 40 FEET
C. MINIMUM SETBACKS
1. FRONT: 40 FEET
2. REAR: 20 FEET
3. SIDE: 5 FEET
III. ACCESS AND CIRCULATION
DEXTER ROAD SHALL BE DEDICATED AND IMPROVED 57 FEET FROM CENTERLINE
IV. LANDSCAPING AND SCREENING
A. EVERGREEN SHRUBS SHALL BE PROVIDED ALONG THE FRONTAGE OF DEXTER ROAD IN LIEU
OF STREET TREES (DUE TO OHE)
B. EACH LOT SHALL HAVE A MINIMUM OF ONE STREET TREE PLANTED BY THE BUILDING
PERMIT HOLDER.
V. DRAINAGE
A. ALL DRAINAGE PLANS TO BE SUBMITTED TO CITY ENGINEER(S) FOR REVIEW.
B. AN OVERALL DRAINAGE PLAN FOR THE ENTIRE SITE SHALL BE SUBMITTED TO THE CITY
ENGINEER BEFORE ANY FINAL PLAN IS RECORDED.
C. DRAINAGE IMPROVEMENTS TO BE PROVIDED UNDER CONTRACT IN ACCORDANCE WITH
THE SUBDIVISION REGULATIONS, AND THE CITY OF MEMPHIS DRAINAGE DESIGN
MANUAL.
D. DESIGN OF THE STORM WATER CONVEYANCE AND MANAGEMENT FACILITIES FOR THIS
PROJECT SHALL BE IN ACCORDANCE WITH THE "CITY OF MEMPHIS DRAINAGE DESIGN
MANUAL". THE MANUAL REQUIRED ON -SITE DETENTION OF STORMWATER RUN -OFF,
GENERATED FROM THIS PROJECT, WHICH EXCEEDS THE CAPACITY OF THE DOWN STREAM
SYSTEM. DRAINAGE CALCULATIONS PERFORMED IN ACCORDANCE WITH THE MANUAL
SHALL BE SUBMITTED VERIFYING THAT ADEQUATE NON -BUILDABLE AREAS HAVE BEEN
PROVIDED FOR STORM WATER DETENTION FACILITIES. FOR INFORMATION CONCERNING
THIS REQUIREMENT, PLEASE CONTACT THE CITY ENGINEER'S OFFICE.
E. THE FOLLOWING NOTE SHALL BE PLACED ON THE FINAL PLAT OF ANY DEVELOPMENT
REQUIRING ON -SITE STORM WATER DETENTION FACILITIES. THE AREAS DENOTED BY
"RESERVED FOR STORMWATER DETENTION" SHALL NOT BE USED AS A BUILDING SITE OR
FILLED WITHOUT FIRST OBTAINING PERM ISSION FROM THE CITY OR COUNTY ENGINEER,
AS APPLICABLE. THE STORMWATER DETENTION SYSTEMS LOCATED IN THESE AREAS,
EXCEPT FOR THOSE PART LOCATED IN A PUBLIC DRAINAGE EASEMENT, SHALL BE OWNED
AND MAINTAINED BY THE PROPERTY OWNER AND/OR PROPERTY OWNERS' ASSOCIATION.
SUCH MAINTENANCE SHALL BE PERFORMED SO AS TO ENSURE THAT THE SYSTEM
Letter to Applicant
PD 2025-014
Page 3 of 3
OPERATES IN ACCORDANCE WITH THE APPROVED PLAN ON FILE IN THE CITY/COUNTY
ENGINEER'S OFFICE. SUCH MAINTENANCE SHALL INCLUDE, BUT NO BE LIMITED TO
REMOVAL OF SEDIMENTATION, FALLEN OBJECTS, DEBRIS AND TRASH, MOWING, OUTLET
CLEANING, AND REPAIR OF DRAINAGE STRUCTURES.
VI. SITE PLAN REVIEW
A SITE PLAN SHALL BE SUBMITTED FOR REVIEW, COMMENT AND RECOMMENDATION OF THE
DIVISION OF PLANNING AND DEVELOPMENT (DPD)
VII. THE LAND USE CONTROL BOARD MAY MODIFY THE BUILDING SETBACK, BUILDING HEIGHT,
ACCESS, PARKING, LANDSCAPING AND SIGN REQUIREMENTS IF EQUIVALENT ALTERNATIVES
ARE PRESENTED.
VIII. A FINAL PLAN SHALL BE FILED WITHIN FIVE YEARS OF APPROVAL OF THE OUTLINE PLAN. THE
LAND USE CONTROL BOARD MAY GRANT EXTENSIONS AT THE REQUEST OF THE APPLICANT.
IX. ANY FINAL PLAN SHALL INCLUDE THE FOLLOWING:
A. THE OUTLINE PLAN CONDITIONS
B. A STANDARD SUBDIVISION CONTRACT AS DEFINED BY THE SUBDIVISION REGULATIONS
FOR ANY NEEDED PUBLIC IMPROVEMENTS.
C. THE LOCATION AND OWNERSHIP, WHETHER PUBLIC OR PRIVATE, OF ANY EASEMENT.
D. A STATEMENT CONVEYING ALL COMMON FACILITIES AND AREAS TO A PROPERTY
OWNER'S ASSOCIATION, OR OTHER ENTITY, FOR OWNERSHIP AND MAINTENANCE
PURPOSES.
E. THE FOLLOWING NOTE SHALL BE PLACED ON THE FINAL PLAT OF ANY DEVELOPMENT
REQUIRING ON -SITE STORMWATER DETENTION FACILITIES. THE AREAS DENOTED BY
"RESERVED FOR STORMWATER DETENTION" SHALL NOT BE USED AS A BUILDING SITE OR
FILLED WITHOUT FIRST OBTAINING WRITTEN PERMISSION FROM THE CITY OR COUNTY
ENGINEER, AS APPLICABLE. THE STORMWATER DETENTION SYSTEMS LOCATED IN THESE
AREAS, EXCEPT FOR THOSE PARTS LOCATED IN A PUBLIC DRAINAGE EASEMENT, SHALL BE
OWNED AND MAINTAINED BY THE PROPERTY OWNER AND OR PROPER5TY OWNERS'
ASSOCIATION. SUCH MAINTENANCE SHALL BE PERFORMED SO AS TO ENSURE THAT THE
SYSTEM OPERATES IN ACCORDANCE WITH THE APPROVED PLAN ON FILE IN THE 4 CITY /
COUNTY ENGINEER'S OFFICE. SUCH MAINTENANCE SHALL INCLUDE, BUT NOT BE LIMITED
TO REMOVAL OF SEDIMENTATION, FALLEN OBJECTS, DEBRIS AND TRASH, MOWING,
OUTLET CLEANING AND REPAIR OF DRAINAGE STRUCTURES.
CITY OF MEMPHIS
COUNCIL AGENDA CHECK OFF SHEET
___________________________________________________________________________________
| ONE ORIGINAL | Planning & Development
| ONLY STAPLED | DIVISION
|TO DOCUMENTS| Planning & Zoning COMMITTEE: 12/2/2025
DATE
PUBLIC SESSION: 12/16/2025
DATE
ITEM (CHECK ONE)
ORDINANCE X RESOLUTION REQUEST FOR PUBLIC HEARING
= = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = =
ITEM DESCRIPTION: Resolution pursuant to Chapter 9.6 of the Memphis and Shelby County Unified Development Code approving
a special use permit at the subject property located at 577 East Raines Road, known as case number SUP 2025-
024
CASE NUMBER: SUP 2025-024
LOCATION: 577 East Raines Road
COUNCIL DISTRICTS: District 6 and Super District 8 – Positions 1, 2, and 3
OWNER/APPLICANT: Damian Wallace, Bright Star Learning Academy
REPRESENTATIVE: N/A
REQUEST: Special use permit to allow a childcare center
AREA: +/-15,289 square feet
RECOMMENDATION: The Division of Planning and Development recommended Approval with conditions
The Land Use Control Board recommended Approval with conditions
RECOMMENDED COUNCIL ACTION: Public Hearing Not Required
Public hearing – December 16, 2025
= = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = =
PRIOR ACTION ON ITEM:
(1) APPROVAL - (1) APPROVED (2) DENIED
11/13/2025 DATE
(1) Land Use Control Board ORGANIZATION - (1) BOARD / COMMISSION
(2) GOV’T. ENTITY (3) COUNCIL COMMITTEE
= = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = =
FUNDING:
(2) REQUIRES CITY EXPENDITURE - (1) YES (2) NO
$ AMOUNT OF EXPENDITURE
$ REVENUE TO BE RECEIVED
SOURCE AND AMOUNT OF FUNDS
$ OPERATING BUDGET
$ CIP PROJECT #_______________________________
$ FEDERAL/STATE/OTHER
= = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = =
ADMINISTRATIVE APPROVAL: DATE POSITION
_____________________________________________ __11/21/2025_ PLANNER II
_____________________________________________ ____________ DEPUTY ADMINISTRATOR
_____________________________________________ ____________ ADMINISTRATOR
_____________________________________________ ____________ DIRECTOR (JOINT APPROVAL)
_____________________________________________ ____________ COMPTROLLER
_____________________________________________ ____________ FINANCE DIRECTOR
_____________________________________________ ____________ CITY ATTORNEY
= = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = =
_____________________________________________ ____________ CHIEF ADMINISTRATIVE OFFICER
_____________________________________________ ____________ COMMITTEE CHAIRMAN
11/21/2025
Memphis City Council
Summary Sheet
SUP 2025-024
RESOLUTION PURSUANT TO CHAPTER 9.6 OF THE MEMPHIS AND SHELBY COUNTY
UNIFIED DEVELOPMENT CODE APPROVING A SPECIAL USE PERMIT AT THE SUBJECT
PROPERTY LOCATED AT 577 EAST RAINES, KNOWN AS CASE NUMBER SUP 2025-024
• This item is a resolution with conditions for a special use permit to allow a
childcare center; and
• The item may require future public improvement contracts.
1
LAND USE CONTROL BOARD RECOMMENDATION
At its re
gular meeting on Thursday, November 13, 2025, the Memphis and Shelby County Land Use
Control Board held a public hearing on the following application:
CASE NUM
BER: SUP 2025-024
LOCATION
: 577 East Raines
COUNCI
L DISTRICT(S): District 6 and Super District 8 – Positions 1, 2, and 3
OWNER/APPL
ICANT: Damion Wallace, Bright Start Learning Academy
REPRESEN
TATIVE: N/A
REQUEST: Sp
ecial use permit to allow a childcare center
EXIST
ING ZONING: Residential Single-Family – 10 (R-10)
AREA: +/-15,
290 square feet
The following spoke in support: None
The following spoke in opposition: None
The La nd Use C ontrol B oard reviewed the a pplication and the staff report. A motion w as mad e an d
seconded to
recommend approval with conditions.
The motion passed by
a vote of 7-0 on the consent agenda.
Respectfully,
Chloe
Christion
Planner II
Land Use and Development Services
Division of Planning and Development
Cc: Committe
e Members
File
2
SUP 2025-024
CONDITIONS
1. The applicant shall submit an updated site and landscape plan subject to the review and approval of
the Division of Planning and Development.
3
SITE PLAN
RESOLUTION PURSUANT TO CHAPTER 9.6 OF THE MEMPHIS AND SHELBY COUNTY
UNIFIED DEVELOPMENT CODE APPROVING A SPECIAL USE PERMIT AT THE SUBJECT
PROPERTY LOCATED AT 577 EAST RAINES, KNOWN AS CASE NUMBER SUP 2025-024
WHEREAS, Chapter 9.6 of the Memphis and Shelby County Unified Development Code, being a
section of the Joint Ordinance Resolution No. 5367, dated August 10, 2010, authorizes the Council of the
City of Memphis to grant a special use permit for certain stated purposes in the various zoning districts;
and
WHEREAS, Damion Wallace filed an application with the Memphis and Shelby County Division
of Planning and Development to allow a childcare center; and
WHEREAS, the Division of Planning and Development has received and reviewed the application
in accordance with procedures, objectives, and standards for special use permits as set forth in Chapter 9.6
with regard to the proposed development's impacts upon surrounding properties, availability of public
facilities, both external and internal circulation, land use compatibility, and that the design and amenities
are consistent with the public interest; and has submitted its findings and recommendation concerning the
above considerations to the Land Use Control Board; and
WHEREAS, a public hearing in relation thereto was held before the Memphis and Shelby County
Land Use Control Board on November 13, 2025, a nd said Board has submitted its findings and
recommendation concerning the above considerations to the Council of the City of Memphis; and
WHEREAS, the Council of the City of Memphis has reviewed the aforementioned application
pursuant to Tennessee Code Annotated Section 13-4- 202(B)(2)(B)(iii) and has determined that said
development is consistent with the Memphis 3.0 General Plan; and
WHEREAS, the Council of the City of Memphis has reviewed the recommendation of the Land
Use Control Board and the report and recommendation of the Division of Planning and Development and
has determined that said development meets the objectives, standards and criteria for a special use permit,
and said development is consistent with the public interests.
NOW, THEREFORE, BE IT RESOLVED, BY THE COUNCIL OF THE CITY OF
MEMPHIS, that, pursuant to Chapter 9.6 of the Memphis and Shelby County Unified Development Code,
a special use permit is hereby granted for the request use in accordance with the attached conditions.
BE IT FURTHER RESOLVED , that this permit merely authorizes the filing of applications to
acquire a Certificate of Use and Occupancy, or a Building Permit, and other required permits and approvals,
provided that no such Certificate of Use and Occupancy shall be granted until all conditions imposed by
the Council of the City of Memphis have been met.
BE IT FURTHER RESOLVED , that this Resolution take effect from and after the date it shall
have been passed by this Council of the City of Memphis, and become effective as otherwise provided by
law, and thereafter shall be treated as in full force and effect by virtue of passage thereof by the Council of
the City of Memphis, the public welfare requiring same.
CONDITIONS
1. The applicant shall submit an updated site and landscape plan subject to the review and approval of the
Division of Planning and Development.
SITE PLAN
ATTEST:
CC: Division of Planning and Development
– Land Use and Development Services
– Office of Construction Enforcement
Staff Writer: Chloe Christion E-mail: chloe.christion@memphistn.gov
AGENDA ITEM: 2 L.U.C.B. MEETING: November 13, 2025
CASE NUMBER: SUP 2025-024
LOCATION: 577 East Raines Road
COUNCIL DISTRICT: District 6 and Super District 8 – Positions 1, 2, and 3
OWNER/APPLICANT: Damion Wallace
REPRESENTATIVE: N/A
REQUEST: Special use permit to allow a childcare center
EXISTING ZONING: Residential Single-family – 10 (R-10)
CONCLUSIONS
1. On October 22, 2025, the Memphis and Shelby County Board of Adjustment approved a variance from
Items 2.6.2B(3)(a) and 2.6.2B(3)(b) of the Memphis and Shelby County Unified Development Code to
allow a childcare center on a lot less than 20,000 square feet and located in a residential district within
1,320 feet of another childcare center. See enclosed Notice of Disposition on pages 19-20.
2. The site plan proposed minimal changes to the existing nature of the site with the exception of a
playground area to the rear of the principal structure. The principal structure on the property and
covered parking area are proposed to remain.
3. In terms of the use itself, staff finds a childcare center is an appropriate use at the subject property. The
property’s unique history as a pre-existing office space in a residentially zoned area, and surrounded by
a mix of non-residential uses including places of worship, a tire shop, and restaurants.
4. The granting of this special use permit will not cause substantial detriment to the public good, nor will
it substantially impair the intent and purpose of an adopted plan or the Unified Development Code
(UDC), nor will it be injurious to the neighborhood or the general welfare, and it will be in harmony with
the purpose and intent of the UDC.
CONSISTENCY WITH MEMPHIS 3.0
This proposal is consistent with the Memphis 3.0 General Plan per the land use decision criteria. See further
analysis on pages 15-17 of this report.
RECOMMENDATION:
Approval with conditions
Staff Report November 13, 2025
SUP 2025-024 Page 2
2
LOCATION MAP
Subject property located within the pink circle
SUBJECT PROPERTY
Staff Report November 13, 2025
SUP 2025-024 Page 3
3
PUBLIC NOTICE VICINITY MAP
Subject property outlined in red
PUBLIC NOTICE DETAILS
In accordance with Sub-Section 9.3.4A of the Unified Development Code, a notice of public hearing is required
to be mailed and signage posted. A total of 97 notices were mailed on August 22, 2025, see page 18 of this
report for a copy of said notice. Additionally, one sign was posted at the subject property, see page 19 of this
report for a copy of the sign affidavit.
NEIGHBORHOOD MEETING
The meeting was held at 5:30 PM on Monday, September 1 at 577 East Raines Road.
Staff Report November 13, 2025
SUP 2025-024 Page 4
4
RAINES TERRACE SUBDIVISION (PLAT BOOK 20 PAGE 18)
Subject property highlighted in yellow, Lot 25
Staff Report November 13, 2025
SUP 2025-024 Page 5
5
AERIAL
Subject property outlined in yellow, imagery from 2023
Staff Report November 13, 2025
SUP 2025-024 Page 6
6
ZONING MAP
Subject property highlighted in yellow
Staff Report November 13, 2025
SUP 2025-024 Page 7
7
LAND USE MAP
Subject property indicated by a pink star
Staff Report November 13, 2025
SUP 2025-024 Page 8
8
SITE PHOTOS
View of subject property from East Raines Road facing south.
Magnified view of subject property from East Raines Road.
Staff Report November 13, 2025
SUP 2025-024 Page 9
9
SITE PLAN
Staff Report November 13, 2025
SUP 2025-024 Page 10
10
SITE PLAN – MAGNIFIED
Staff Report November 13, 2025
SUP 2025-024 Page 11
11
CASE REVIEW
Request
The request is a special use permit to allow a childcare center.
Approval Criteria
Staff agrees the approval criteria in regard to special use permits as set out in Section 9.6.9 of the Unified
Development Code are met.
9.6.9 Approval Criteria
No special use permit or planned development shall be approved unless the following findings are made
concerning the application:
9.6.9A The project will not have a substantial or undue adverse effect upon adjacent property, the
character of the neighborhood, traffic conditions, parking, utility facilities and other matters
affecting the public health, safety, and general welfare.
9.6.9B The project will be constructed, arranged and operated so as to be compatible with the
immediate vicinity and not interfere with the development and use of adjacent property in
accordance with the applicable district regulations.
9.6.9C The project will be served adequately by essential public facilities and services such as streets,
parking, drainage, refuse disposal, fire protection and emergency services, water and sewers; or
that the applicant will provide adequately for such services.
9.6.9D The project will not result in the destruction, loss or damage of any feature determined by the
governing bodies to be of significant natural, scenic or historic importance.
9.6.9E The project complies with all additional standards imposed on it by any particular provisions
authorizing such use.
9.6.9F The request will not adversely affect any plans to be considered (see Chapter 1.9), or violate the
character of existing standards for development of the adjacent properties.
9.6.9G The governing bodies may impose conditions to minimize adverse effects on the neighborhood
or on public facilities, and to ensure compatibility of the proposed development with surrounding
properties, uses, and the purpose and intent of this development code.
9.6.9H Any decision to deny a special use permit request to place, construct, or modify personal wireless
service facilities shall be in writing and supported by substantial evidence contained in a written
record, per the Telecommunications Act of 1996, 47 USC 332(c)(7)(B)(iii). The review body may
not take into account any environmental or health concerns.
Site Details
Address:
577 East Raines Street
Parcel ID:
076050 00002
Area:
+/-15,290 square feet
Staff Report November 13, 2025
SUP 2025-024 Page 12
12
Description:
The subject property is known as Lot 25 of Raines Terrace Subdivision and is zoned Residential Single-family 10
(R-10). Per the Assessor’s website, the principal structure on the lot was built in 1954 as a one-story residence
with a ground floor area of 1,708 square feet. The building has been in use as a dentist office according to Google
Streetview. The surrounding land uses are a mixture of single -family residential, commercial, and institutional.
This lot has one street frontage on East Raines Road.
Site Zoning History
On October 22, 2025, the Memphis and Shelby County Board of Adjustment approved a variance from Items
2.6.2B(3)(a) and 2.6.2B(3)(b) of the Memphis and Shelby County Unified Development Code to allow a childcare
center on a lot less than 20,000 square feet and located in a residential district within 1,320 feet of another
childcare center. See enclosed Notice of Disposition on pages X.
Site Plan Review and Analysis
The site plan proposed minimal changes to the existing nature of the site with the exception of a playground
area to the rear of the principal structure. The principal structure on the property and covered parking area are
proposed to remain.
The proposed site plan lacks detail in terms of landscaping and designated pick -up and drop off location for
children. Staff has conditions that the applicant submit an updated plan showing the required Class II landscape
buffer along property lines abutting residential uses as well as a designated pick up and drop off location on site
near the building entrance.
In terms of the use itself, staff finds a childcare center is an appropriate use at the subject property. The
property’s unique history as a pre -existing office space in a residentially zoned area, and surrounded by a mix
of non-residential uses including places of worship, a tire shop, and restaurants.
The granting of this special use permit will not cause substantial detriment to the public good, nor will it
substantially impair the intent and purpose of an adopted plan or the Unified Development Code (UDC), nor will
it be injurious to the neighborhood or the general welfare, and it will be in harmony with the purpose and intent
of the UDC.
RECOMMENDATION
Staff recommends approval with conditions.
Conditions
1. The applicant shall submit an updated site and landscape plan subject to the review and approval of the
Division of Planning and Development.
Staff Report November 13, 2025
SUP 2025-024 Page 13
13
DEPARTMENTAL COMMENTS
The following comments were provided by agencies to which this application was referred:
City Engineer: No comments received.
City Fire Division: See page 14.
City Real Estate: No comments received.
County Health Department: No comments received.
Shelby County Schools: No comments received.
Construction Code Enforcement: No comments received.
Memphis Light, Gas and Water: No comments received.
Office of Sustainability and Resilience: No comments received.
Office of Comprehensive Planning: See pages 15-17.
Staff Report November 13, 2025
SUP 2025-024 Page 14
14
DIVISION OF FIRE SERVICES FIRE PREVENTION BUREAU
2668 Avery Avenue ⋅ Memphis ⋅ Tennessee ⋅ 38112
(901) 636-5401 Fax (901) 320-5425
Case Number: SUP 2025-024
Date Reviewed: 11/7/25
Reviewed by: J. Stinson
Address or Site Reference: 577 E Raines
• All design and construction shall comply with the 2021 edition of the International Fire Code (as locally
amended) and referenced standards.
• A detailed plans review will be conducted by the Memphis Fire Prevention Bureau upon receipt of complete
construction documents. Plans shall be submitted to the Shelby County Office of Code Enforcement.
Staff Report November 13, 2025
SUP 2025-024 Page 15
15
Comprehensive Planning Review of Memphis 3.0 Consistency
This summary is being produced in response to the following application to support the Land Use and
Development Services department in their recommendation: SUP 2025-024: Westwood
Site Address/Location: 577 E Raines Rd.
Overlay District/Historic District/Flood Zone: Not located in an Overlay District, Historic District, or Flood Zone
Future Land Use Designation: Primarily Single-Unit Neighborhood (NS)
Street Type: Parkway
The applicant is requesting a special use permit to allow a childcare center in the R esidential Single-Family -10
(R-10) district.
The following information about the land use designation can be found on pages 76 – 122:
1. Future Land Use Planning Map
Red polygon indicates the application site on the Future Land Use Map.
Staff Report November 13, 2025
SUP 2025-024 Page 16
16
2. Land Use Description/Intent
Primarily Single -Unit Neighborhood (NS) are residential neighborhoods
consisting primarily of single -unit houses that are not near a Community
Anchor. Graphic portrayal of NS is to the right.
“NS” Form & Location Characteristics
Primarily detached, House scale buildings, Primarily residential, 1 – 3 stories; Beyond ½ mile from a Community
Anchor
“NS” Zoning Notes
Generally compatible with the following zone districts: R -E, R-15, R-10, R-8, R-6 in accordance with Form and
characteristics listed above.
Existing, Adjacent Land Use and Zoning
Existing Land Use and Zoning: Office; R-10
Adjacent Land Use and Zoning: Single-Family, Commercial, Institutional; R-10, CMU-1, and RW
Overall Compatibility: This requested use is compatible with the future land use description/intent, form and
location characteristics, zoning notes, and surrounding land uses as a proposed childcare center in the Residential
Single-Family district. To further enhance compatibility, the site should incorporate appropriate landscaping and
pedestrian safety features to create a safe and welcoming environment for children and families.
Degree of Change Map
Red polygon denotes the proposed site on the Degree of Change Map. There is no Degree of Change.
3. Degree of Change Description
N/A
4. Objectives/Actions Consistent with Goal 1, Complete, Cohesive, Communities
Staff Report November 13, 2025
SUP 2025-024 Page 17
17
N/A
5. Pertinent Sections of Memphis 3.0 that Address Land Use Recommendations
N/A
Consistency Analysis Summary
The applicant is requesting a special use permit to allow a childcare center in the residential single family-10 (R-
10) district.
This requested use is compatible with the future land use description/intent, form and location characteristics,
zoning notes, and surrounding land uses as a proposed childcare center in the Residential Single-Family district.
To further enhance compatibility, the site should incorporate appropriate landscaping and pedestrian safety
features to create a safe and welcoming environment for children and families.
Based on the information provided, the proposal is CONSISTENT with the Memphis 3.0 Comprehensive Plan.
Summary Compiled by: Negin Hamidi, Comprehensive Planning.
Staff Report November 13, 2025
SUP 2025-024 Page 18
18
MAILED PUBLIC NOTICE
Staff Report November 13, 2025
SUP 2025-024 Page 19
19
BOA 2025-0100 NOTICE OF DISPOSITION
Staff Report November 13, 2025
SUP 2025-024 Page 20
20
Staff Report November 13, 2025
SUP 2025-024 Page 21
21
SIGN AFFIDAVIT
Staff Report November 13, 2025
SUP 2025-024 Page 22
22
APPLICATION
Staff Report November 13, 2025
SUP 2025-024 Page 23
23
Staff Report November 13, 2025
SUP 2025-024 Page 24
24
Staff Report November 13, 2025
SUP 2025-024 Page 25
25
OWNER AFFIDAVIT
Staff Report November 13, 2025
SUP 2025-024 Page 26
26
LETTER OF INTENT
Staff Report November 13, 2025
SUP 2025-024 Page 27
27
LETTERS RECEIVED
No letters received at the time of completion of this report.
East Service Center: 6465 Mullins Station Rd; Memphis,
Tennessee
38134
Downtown Service Center: 125 N. Main Street;
Memphis, T
ennessee 38103
website: www.develop901.com
Memphis and Shelby County Division of
Planning and Development
Record Summary for Special Use Permit
Record Detail Information
Record T
ype: Special Use Permit Record Status: Pending
Opened Date:
July 31, 2025
Record Number: SUP 2025-024
Record Name: Daycare eenter
Expiration Date:
Description of Work: Opening a daycare center
Parent Record Number:
Address:
577 E RAINES RD, MEMPHIS 38109
Owner Information
Primary Owner Name
Owner
Address Owner Phone
Y Mason Real Estate Holdings LLC
577 E RAINES RD, MEMPHIS, TN 38109
Parcel Information
076050 00002
Data Fields
PREAPPLICA
TION MEETING
Name of DPD Planner Damion Wallace
Date of Meeting -
Pre-
application Meeting Type -
GENERAL PROJECT INFORMATION
Application Type New Special Use Permit (SUP)
List any relevant former Docket / Case
Number(s) related to previous applications on
this site
NA
Is this application in response to a citation, stop
work order, or zoning letter
No
Page 1 of 3 SUP 2025-024
GENERAL PROJECT INFORMATION
If yes, please provide a copy of the citation, stop
work order, and/or zoning letter along with any
other relevant information
NA
APPROVAL CRITERIA
A) The project will not have a substantial or
undue adverse ef
fect upon adjacent property, the
character of the neighborhood, traffic conditions,
parking, utility facilities and other matters
affecting the public health, safety, and general
welfare
Yes
B) The project will be constructed, arranged and
operated so as to be compatible with the
immediate vicinity and not interfere with the
development and use of adjacent property in
accordance with the applicable district
regulations
Yes
UDC Sub-Section 9.6.9C Yes
UDC Sub-Section 9.6.9D Yes
UDC Sub-Section 9.6.9E Yes
UDC Sub-Section 9.6.9F Correct
GIS INFORMATION
Case Layer -
Central Business Improvement District No
Class C
Downtown Fire District No
Historic District -
Land Use OFFICE
Municipality MEMPHIS
Overlay/Special Purpose District -
Zoning R-10
State Route -
Lot 0 25
Subdivision RAINES TERRACE RE
Planned Development District -
Wellhead Protection Overlay District No
County Commission District -
City Council District -
City Council Super District -
Contact Information
Page 2 of 3 SUP 2025-024
DAMION WALLACE
(901)907-9995
APPLICANT
Name
Address
Phone
Contact Type
DAMION WALLACE
(901)907-9995
PROPER
TY OWNER OF
RECORD
Name
Address
Phone
Contact Type
Fee Information
Date AssessedBalanceStatusFeesQuantityFee ItemInvoice #
07/31/20250.00INVOICED500.001Special Use Permit Fee -
5 acres or less (Base Fee)
1667420
07/31/20250.00INVOICED250.001Child Care Center (13+
children)
1667420
07/31/20250.00INVOICED19.501Credit Card Use Fee (.026
x fee)
1667420
Total Fee Invoiced
: $769.50 Total Balance: $0.00
Payment Information
Payment Amount Method of Payment
Credit Card$769.50
Page 3 of 3 SUP 2025-024
Skeen Engineering
SCALE :
REF. MATL. :
SURVEY CLASS :
DWG DATE:
SURV DATE:
CLIENT:
NORTH REF. :
PROJ. NUM.
Civil Engineering | Land Surveying
P.O. Box 590 · Hernando, MS 38632
(662) 721-2772 | skeenengineering.com PATH :
GRAPHIC SCALE
SURVEY LINE LEGEND
Letter of Intent to Open Daycare Center
Damion Wallace
Bright Start Learning Academy No. 4, Inc
577 East Raines Road , Memphis, TN 38109
Email: BSLAMemphis@yahoo.com
Phone: 901-907-9995
Date: July 30, 2025
To Whom It May Concern,
I am writing to formally express my intent to open a licensed childcare facility under the name Bright Start
Learning Academy No. 4, Inc, located at 577 East Raines Road, Memphis, Tennessee 38109.
With over 20 years of experience in early childhood education, our team brings a strong foundation of knowledge,
care, and quality programming. We currently operate Bright Start Learning Academy No. 3 in Southaven,
Mississippi, and two additional daycare locations in Illinois. Our mission is to expand this same high standard of
care and education to families in the Whitehaven area of Memphis.
The center will serve children ages 6 weeks to 6 years, offering a high-quality, developmentally appropriate
program with a focus on early learning, kindergarten readiness, and whole-child development. Services will
include full-day childcare, curriculum-based instruction, meals prepared on site, and video-monitored classrooms
in a clean, safe, and nurturing environment.
We anticipate opening in Fall 2025, pending approval of all local and state licensing requirements, building
inspections, and necessary permits. The facility will operate Monday through Friday, from 6:30 AM to 5:00 PM.
The mission of BSLA Memphis is to support working families by providing safe, structured, and enriching care that
supports children's growth across all domains, cognitive, language, physical, social-emotional, and creative
development. Our program will follow the Tennessee Early Learning Developmental Standards (TN-ELDS) and
operate in compliance with all Department of Human Services (DHS) childcare regulations.
I appreciate your time and consideration of this notice and look forward to working collaboratively with the
appropriate agencies to bring this essential service to the Whitehaven community.
Please do not hesitate to reach out if any further documentation is required.
Sincerely,
Damion Wallace
Damion Wallace
Owner/Director
City Hall – 125 N. Main Street, Suite 468 – Memphis, Tennessee 38103 – (901) 636-6619
November 13, 2025
Bright Start Learning Academy
577 E Raines Road
Memphis, TN 38109
Sent via electronic mail to: BSLAMemphis@yahoo.com
Case Number: SUP 2025-024
LUCB Recommendation: Approval with conditions
Dear applicant,
On Thursday, November 13, 2025, t he Memphis and Shelby County Land Use Control Board
recommended approval of your special use permit application to allow a childcare center at 577
East Raines Road, subject to the following conditions:
1. The applicant shall submit an updated site and landscape plan subject to the review and
approval of the Division of Planning and Development.
This application will be forwarded, for final action, to the Council of the City of Memphis. The Council
will review your application in a committee meeting prior to voting on it in a public hearing. The
applicant or the applicant’s representative(s) shall be in attendance at all meetings and hearings.
It is the applicant’s responsibility to contact the City Council Records Office to determine when the
application is scheduled to be heard at committee and in public session. The City Council Records
Office may be reached at (901) 636-6792.
If for some reason you choose to withdraw your application, a letter should be mailed to the Land
Use and Development Services Department of the Division of Planning and Development at the
address provided above or emailed to the address provided below.
If you have questions regarding this matter, please feel free to contact me at (901) 636-6619 or via
email at chloe.christion@memphistn.gov.
Letter to Applicant
SUP 2025-024
Page 2 of 2
Respectfully,
Chloe Christion
Planner II
Land Use and Development Services
Division of Planning and Development
Cc: Damion Wallace
File
Memphis City Council
Summary Sheet
SUP 25-27
RESOLUTION PURSUANT TO CHAPTER 9.6 OF THE MEMPHIS AND SHELBY COUNTY
UNIFIED DEVELOPMENT CODE APPROVING A SPECIAL USE PERMIT AT THE SUBJECT
PROPERTY LOCATED AT 1032 HALE ROAD KNOWN AS CASE NUMBER SUP 25-27
• This item is a resolution with conditions for a special use permit to allow a child
care center; and
• The item may require future public improvement contracts.
1
LAND USE CONTROL BOARD RECOMMENDATION
At its regular meeting on Thursday, November 13 , 20 25, the Memphis and Shelby County Land Use
Control Board held a public hearing on the following application:
CASE NUMBER: SUP 25-27
LOCATION: 1032 Hale Road
COUNCIL DISTRICT(S): District 6 and Super District 8
OWNER/APPLICANT: BCS Investments LLC/ Brianna Freeman
REPRESENTATIVE: Evelyn Royston
REQUEST: To allow a child care center
EXISTING ZONING: Residential Single-Family – 10 (R-10)
AREA: +/-1.173 a
cres
The following spoke in support: None
The following spoke in opposition: None
The Land Use Control Board reviewed the application and the staff report. A motion was made and
seconded to recommend approval with conditions.
The motion passed by a vote of 7-0 on the consent agenda.
Respectfully,
Nabanita Nira
Planner II
Land Use and Development Services
Division of Planning and Development
Cc: Committee Members
File
2
SUP 25-27
CONDITIONS
1. A maximum of thirty (30) children are allowed.
2. A final site plan with landscaping shall be submitted subject to administrative review and approval by
the Division of Planning and Development.
3. The subject property and the principal structure must maintain its residential character in design and
scale.
3
SITE PLAN
RESOLUTION PURSUANT TO CHAPTER 9.6 OF THE MEMPHIS AND SHELBY COUNTY
UNIFIED DEVELOPMENT CODE APPROVING A SPECIAL USE PERMIT AT THE SUBJECT
PROPERTY LOCATED AT 1032 HALE ROAD, KNOWN AS CASE NUMBER SUP 25-27
WHEREAS, Chapter 9.6 of the Memphis and Shelby County Unified Development Code, being a
section of the Joint Ordinance Resolution No. 5367, dated August 10, 2010, authorizes the Council of the
City of Memphis to grant a special use permit for certain stated purposes in the various zoning districts;
and
WHEREAS, Brianna Freeman filed an application with the Memphis and Shelby County Division
of Planning and Development to allow a child care center; and
WHEREAS, the Division of Planning and Development has received and reviewed the application
in accordance with procedures, objectives, and standards for special use permits as set forth in Chapter 9.6
with regard to the proposed development's impacts upon surrounding properties, availability of public
facilities, both external and internal circulation, land use compatibility, and that the design and amenities
are consistent with the public interest; and has submitted its findings and recommendation concerning the
above considerations to the Land Use Control Board; and
WHEREAS, a public hearing in relation thereto was held before the Memphis and Shelby County
Land Use Control Board on November 13, 20 25, a nd said Board has submitted its findings and
recommendation concerning the above considerations to the Council of the City of Memphis; and
WHEREAS, the Council of the City of Memphis has reviewed the aforementioned application
pursuant to Tennessee Code Annotated Section 13-4- 202(B)(2)(B)(iii) and has determined that said
development is consistent with the Memphis 3.0 General Plan; and
WHEREAS, the Council of the City of Memphis has reviewed the recommendation of the Land
Use Control Board and the report and recommendation of the Division of Planning and Development and
has determined that said development meets the objectives, standards and criteria for a special use permit,
and said development is consistent with the public interests.
NOW, THEREFORE, BE IT RESOLVED, BY THE COUNCIL OF THE CITY OF
MEMPHIS, that, pursuant to Chapter 9.6 of the Memphis and Shelby County Unified Development Code,
a special use permit is hereby granted for the request use in accordance with the attached conditions.
BE IT FURTHER RESOLVED , that this permit merely authorizes the filing of applications to
acquire a Certificate of Use and Occupancy, or a Building Permit, and other required permits and approvals,
provided that no such Certificate of Use and Occupancy shall be granted until all conditions imposed by
the Council of the City of Memphis have been met.
BE IT FURTHER RESOLVED , that this Resolution take effect from and after the date it shall
have been passed by this Council of the City of Memphis, and become effective as otherwise provided by
law, and thereafter shall be treated as in full force and effect by virtue of passage thereof by the Council of
the City of Memphis, the public welfare requiring same.
CONDITIONS
1. A maximum of thirty (30) children are allowed.
2. A final site plan with landscaping shall be submitted subject to administrative review and approval by
the Division of Planning and Development.
3. The subject property and the principal structure must maintain its residential character in design and
scale.
SITE PLAN
ATTEST:
CC: Division of Planning and Development
– Land Use and Development Services
– Office of Construction Enforcement
Staff Writer: Nabanita Nira E-mail: nabanita.nira@memphistn.gov
AGENDA ITEM: 8 L.U.C.B. MEETING: November 13, 2025
CASE NUMBER: SUP 2025-027
LOCATION: 1032 Hale Road
COUNCIL DISTRICT: District 6 and Super District 8
OWNER/APPLICANT: BCS Investments LLC/ Brianna Freeman
REPRESENTATIVE: Evelyn Royston
REQUEST: Special use permit to allow a child care center
EXISTING ZONING: Residential Single-Family – 10 (R-10)
CONCLUSIONS
1. The applicant is proposing to have a child care center for thirty (30) children at the subject property.
2. In 1997 PD 96-361 and in 2002 PD 02 -311 were both approved to allow a child care center at the subject
property. However, despite operating a child care center during this time period neither planned
development was ever memorialized by the recording of a final plat and thus both subsequently expired.
The existing principal structure on the site previously had a certificate of occupancy (BC0011592) for a child
care center with maximum capacity of 30 children which is the same number of children the applican t is
intending to have if the facility is permitted to be reopened.
3. The subject property is approximate 1,200 feet from the intersecting arterial and on October 22, 2025, the
Board of Adjustment approved a variance application known as BOA 2025 -0108 from Item 2.6.2B(3)(c) to
allow a child care center at the subject propert y further than 200 feet from an intersecting arterial road,
see pages 16-17 of this report for said notice of disposition.
4. According to the applicant, the site is suitable for a child care center as it was previously used as a child
care center with a fenced playground. The site has a drop off and pick up with circular drive and the
applicant is proposing to have an ADA access ible ramp. Also, the proposal is consistent with the Memphis
3.0 Comprehensive Plan.
5. The granting of this special use permit will not cause substantial detriment to the public good, nor will it
substantially impair the intent and purpose of an adopted plan or the Unified Development Code (UDC),
nor will it be injurious to the neighborhood or the general welfare, and it will be in harmony with the
purpose and intent of the UDC.
CONSISTENCY WITH MEMPHIS 3.0
This proposal is consistent with the Memphis 3.0 General Plan per the land use decision criteria. See further
analysis on pages 21-24 of this report.
RECOMMENDATION:
Approval with conditions
Staff Report November 13, 2025
SUP 2025-027 Page 2
2
LOCATION MAP
Subject property located within the pink circle
SUBJECT PROPERTY
Staff Report November 13, 2025
SUP 2025-027 Page 3
3
PUBLIC NOTICE VICINITY MAP
Subject property highlighted in yellow
PUBLIC NOTICE DETAILS
In accordance with Sub-Section 9.3.4A of the Unified Development Code, a notice of public hearing is required
to be mailed and signage posted . A total of 90 notices were mailed on October 10, 2025, see page 25 of this
report for a copy of said notice. Additionally, one sign was posted at the subject property, see pages 26-27 of
this report for a copy of the sign affidavit.
NEIGHBORHOOD MEETING
The meeting was held at 5:00 PM on Thursday, October 30, 2025, at 1032 Hale Rd.
Staff Report November 13, 2025
SUP 2025-027 Page 4
4
WHITEHAVEN HEIGHTS SUNDIVISION (1919) (PLAT BOOK 8 PAGE 255)
Subject property highlighted in yellow, Lot 52
Staff Report November 13, 2025
SUP 2025-027 Page 5
5
AERIAL
Subject property outlined in yellow, imagery from 2023
Staff Report November 13, 2025
SUP 2025-027 Page 6
6
ZONING MAP
Subject property highlighted in yellow
Staff Report November 13, 2025
SUP 2025-027 Page 7
7
LAND USE MAP
Subject property indicated by a pink star
Staff Report November 13, 2025
SUP 2025-027 Page 8
8
SITE PHOTOS
View of subject property from Hale Road looking northwest
View of subject property from Hale Road looking northeast
Staff Report November 13, 2025
SUP 2025-027 Page 9
9
SITE PLAN
Staff Report November 13, 2025
SUP 2025-027 Page 10
10
SITE PLAN (MAGNIFIED)
Staff Report November 13, 2025
SUP 2025-027 Page 11
11
FLOOR PLAN
Staff Report November 13, 2025
SUP 2025-027 Page 12
12
CASE REVIEW
Request
The request is a special use permit to allow a childcare center in Residential Single -Family – 10 (R-10) zoning
district.
Approval Criteria
Staff agrees the approval criteria in regard to special use permits as set out in Section 9.6.9 of the Unified
Development Code are met.
9.6.9 Approval Criteria
No special use permit or planned development shall be approved unless the following findings are made
concerning the application:
9.6.9A The project will not have a substantial or undue adverse effect upon adjacent property, the
character of the neighborhood, traffic conditions, parking, utility facilities and other matters
affecting the public health, safety, and general welfare.
9.6.9B The project will be constructed, arranged and operated so as to be compatible with the
immediate vicinity and not interfere with the development and use of adjacent property in
accordance with the applicable district regulations.
9.6.9C The project will be served adequately by essential public facilities and services such as streets,
parking, drainage, refuse disposal, fire protection and emergency services, water and sewers; or
that the applicant will provide adequately for such services.
9.6.9D The project will not result in the destruction, loss or damage of any feature determined by the
governing bodies to be of significant natural, scenic or historic importance.
9.6.9E The project complies with all additional standards imposed on it by any particular provisions
authorizing such use.
9.6.9F The request will not adversely affect any plans to be considered (see Chapter 1.9), or violate the
character of existing standards for development of the adjacent properties.
9.6.9G The governing bodies may impose conditions to minimize adverse effects on the neighborhood
or on public facilities, and to ensure compatibility of the proposed development with surrounding
properties, uses, and the purpose and intent of this development code.
9.6.9H Any decision to deny a special use permit request to place, construct, or modify personal wireless
service facilities shall be in writing and supported by substantial evidence contained in a written
record, per the Telecommunications Act of 1996, 4 7 USC 332(c)(7)(B)(iii). The review body may
not take into account any environmental or health concerns.
Site Details
Address:
1032 Hale Road
Parcel ID:
077047 00045
Area:
+/-1.173 acres
Staff Report November 13, 2025
SUP 2025-027 Page 13
13
Description:
The subject property is known as Lot 52 of Whitehaven heights subdivision and zoned Residential Single-Family
– 10 (R-10). Per the Assessor’s website, the site has a one-story principal structure constructed circa 1936 with
1,360 sq. ft. floor area. The site has an existing playground at the rear surrounded by a wood fence. There is an
existing circular driveway.
Site Zoning History
On April 12, 1962, the Board of Adjustment rejected an application to operate a child care nursery in R-I District
know as docket BOA 1962-013 CO on the subject property.
In January 1997, Little Eagles Child Development Center P.D. was approved with a maximum of thirty (30)
children on the subject property.
On September 17, 2002, the Council of the City of Memphis approved PD 02 -311 (formerly PD 96 -361) for
Whitehaven Heights Planned Development (formerly Little Eagles Child Development Center P.D.) that allows a
day care center to serve a maximum of sixty (6 0) children on the subject property. However, the planned
development was never recorded and expired subsequently.
On October 22, 2025, the Board of Adjustment approved a variance application known as BOA 2025-0108 from
Item 2.6.2B(3)(c) to allow a child care center at the subject property further than 200 feet from an intersecting
arterial road, see pages 16-17 of this report for said notice of disposition.
Relevant Unified Development Code Clauses
Section 2.5.2
Site Plan Review
• The 1.173 acres site has an existing structure of 1,360 sq. ft.
• An existing playground at the rear surrounded by a wood fence.
• Existing circular driveway.
• Proposed ADA ramp at the entrance of the structure.
• A parking area or drive aisle of 8 parking space. The parking area requires to screen from abutting property
and the right-of-way. A 6-foot height wooden fence is required starting at the front façade of the building
and continuing northward until the parking is fully screened and evergreen shrubs to hide the parking area
from right-of-way, see the following where the red line represents the 6 -foot wood fence and green circle
represents the landscaping with evergreen shrubs.
Staff Report November 13, 2025
SUP 2025-027 Page 14
14
• The existing tree on the property needs to be shown on the final site plan.
Analysis
The applicant is requesting to have a child care center in R-10 zoning district. The applicant is proposing to have
thirty (30) children at the subject property.
In 1997 PD 96 -361 and in 2002 PD 02 -311 were both approved to allow a child care center at the subject
property. However, despite operating a child care center during this time period neither planned development
was ever memorialized by the recording of a final plat and thus both subsequently expired. The existing principal
structure on the site previously had a certificate of occupancy (BC0011592) for a child care center with maximum
capacity of 30 children which is the same number of children the applican t is intending to have if the facility is
permitted to be reopened.
The subject property is approximate 1,200 feet from the intersecting arterial and on October 22, 2025, the Board
of Adjustment approved a variance application known as BOA 2025-0108 from Item 2.6.2B(3)(c) to allow a child
care center at the subject property further than 200 feet from an intersecting arterial road, see pages 16-17 of
this report for said notice of disposition.
Staff Report November 13, 2025
SUP 2025-027 Page 15
15
According to the applicant, the site is suitable for a child care center as it was previously used as a child care
center with a fenced playground. The site has a drop off and pick up with circular drive and the applicant is
proposing to have an ADA accessible ramp. Also, the proposal is consistent with the Memphis 3.0
Comprehensive Plan.
The granting of this special use permit will not cause substantial detriment to the public good, nor will it
substantially impair the intent and purpose of an adopted plan or the Unified Development Code (UDC), nor will
it be injurious to the neighborhood or the general welfare, and it will be in harmony with the purpose and intent
of the UDC.
RECOMMENDATION
Staff recommends approval with conditions.
Conditions
1. A maximum of thirty (30) children are allowed.
2. A final site plan with landscaping shall be submitted subject to administrative review and approval by the
Division of Planning and Development.
3. The subject property and the principal structure must maintain its residential character in design and scale.
Staff Report November 13, 2025
SUP 2025-027 Page 16
16
NOTICE OF DISPOSITION (BOA 2025-0108)
Staff Report November 13, 2025
SUP 2025-027 Page 17
17
Staff Report November 13, 2025
SUP 2025-027 Page 18
18
DEPARTMENTAL COMMENTS
The following comments were provided by agencies to which this application was referred:
City Engineer: See pages 19-20 of this report.
City Fire Division: No comments received.
City Real Estate: No comments received.
County Health Department: No comments received.
Shelby County Schools: No comments received.
Construction Code Enforcement: No comments received.
Memphis Light, Gas and Water: No comments received.
Office of Sustainability and Resilience: No comments received.
Office of Comprehensive Planning: See pages 21-24 of this report.
Staff Report November 13, 2025
SUP 2025-027 Page 19
19
CITY ENGINEER COMMENTS
Staff Report November 13, 2025
SUP 2025-027 Page 20
20
Staff Report November 13, 2025
SUP 2025-027 Page 21
21
OFFICE OF COMPREHENSIVE PLANNING COMMENTS
Comprehensive Planning Review of Memphis 3.0 Consistency
This summary is being produced in response to the following application to support the Land Use and
Development Services department in their recommendation: SUP 2025-027
Site Address/Location: 1032 Hale Road
Overlay District/Historic District/Flood Zone: Not in an Overlay District, Historic District, or Flood Zone
Future Land Use Designation: Anchor Neighborhood-Mix of Building Types (AN-M)
Street Type: Local
Applicant is seeking a special use permit to continue a non-conforming use of a 30-child daycare and learning
center.
The following information about the land use designation can be found on pages 76 – 122:
1. Future Land Use Planning Map
Red polygon indicates the application site on the Future Land Use Map.
2. Land Use Description/Intent
Anchor Neighborhood-Mix of Building Types (AN-M) are walkable
neighborhoods within a 5 – 10-minute walk of a Community Anchor. These
neighborhoods are made up of a mix of single-unit and multi-unit housing.
Graphic portrayal of AN-M is to the right.
Staff Report November 13, 2025
SUP 2025-027 Page 22
22
“AN-M” Form & Location Characteristics
NURTURE/SUSTAIN - Primarily detached, single -family residences. Attached single -family, duplexes, triplexes
and quadplexes permitted on parcels within 100 feet of an anchor and at intersections where the presence of
such housing type currently exists; Other housing and commercial types along avenues, boulevards and
parkways as identified in the Street Types Map where same types exist on two or more adjacent parcels. Height:
1-3 stories. Scale: house-scale.
ACCELERATE: Primarily detached, single-family house-scale residences of 1-3 stories in height. Attached, house-
scale single-family, duplexes, triplexes and quadplexes of 1 -3 stories in height permitted on parcels within 200
feet of an anchor and at inters ections where the presence of such housing type currently exists. Building -scale
large homes and apartments of 2 -4 stories in height permitted on parcels within 100 feet of an anchor; at
intersections where the presence of such housing type currently exist s at the intersection. Other housing and
commercial types along avenues, boulevards and parkways as identified in the Street Types Map where same
types exist on one or more adjacent parcels.
“AN-M” Zoning Notes
Generally compatible with the following zone districts: RU-2, RU-3, RU-4, R-SD, R-R, MDR, and CMU-1 when
located along avenues, boulevards, and parkways as identified in the Street Types Map, in accordance with
Form and characteristics listed above.
Existing, Adjacent Land Use and Zoning
Existing Land Use and Zoning: Institutional; R-10
Adjacent Land Use and Zoning: Vacant, Institutional, Single-Family; R-10, CMU-1
Overall Compatibility: This requested use is compatible with the land use description/intent, form & location
characteristics, and zoning notes, but is not consistent with existing, adjacent land use and zoning. A house-
scale daycare/learning center is consistent with a mix of building types. The use also promotes walkability and
community connection via providing a necessary childcare center within a neighborhood.
Staff Report November 13, 2025
SUP 2025-027 Page 23
23
3. Degree of Change Map
Red polygon denotes the proposed site in Degree of Change area. There Degree of Change is Accelerate.
4. Degree of Change Description
Accelerate areas rely on a mix of primarily private and philanthropic resources along with some public
resources to intensify the existing pattern of a place by strengthening existing assets/patterns through
(Primarily) Residential Infill and Intensification. Other modes include increasing the mix of uses and multi-
modal transportation options.
5. Objectives/Actions Consistent with Goal 1, Complete, Cohesive, Communities
The requested use is consistent with Objective 1.5 – Strengthen neighborhood commercial districts Action
1.5.9 - Improve walkability and multimodal access within and around community and Citywide Anchors to
promote local economies and connect neighborhood residents and local businesses.
The requested use is consistent due to the private investment by the daycare that would strengthen
current community connections, the mix of uses, and promotion of walkability through the provision of
childcare within an existing neighborhood. Families who would have otherwise driven to another daycare
have the opportunity to walk to one that is in their own neighborhood.
Staff Report November 13, 2025
SUP 2025-027 Page 24
24
6. Pertinent Sections of Memphis 3.0 that Address Land Use Recommendations
The requested use is consistent with Objective 6.1 – Increase equitable access to education, quality jobs, and
living wages for all residents Action 6.1.4 – Continue the City’s commitment to funding early childhood
education, especially for minorities and other underserved populations.
While not a direct investment by the city, allowing the continued operation of a daycare/learning facility in a
neighborhood is an indirect and consistent way to invest in early childhood care and education for the
community.
Consistency Analysis Summary
Applicant is seeking a special use permit to continue a non-conforming use of a 30-child daycare and learning
center.
This requested use is compatible with the land use description/intent, form & location characteristics, and
zoning notes, but is not consistent with existing, adjacent land use and zoning. A house-scale daycare/learning
center is consistent with a mix of building types. The use also promotes walkability and community connection
via providing a necessary childcare center within a neighborhood.
Accelerate areas rely on a mix of primarily private and philanthropic resources along with some public
resources to intensify the existing pattern of a place by strengthening existing assets/patterns through
(Primarily) Residential Infill and Intensification. Other modes include increasing the mix of uses and multi-
modal transportation options.
The requested use is consistent with Objective 1.5 – Strengthen neighborhood commercial districts Action
1.5.9 - Improve walkability and multimodal access within and around community and Citywide Anchors to
promote local economies and connect neighborhood residents and local businesses.
The requested use is consistent with Objective 6.1 – Increase equitable access to education, quality jobs, and
living wages for all residents Action 6.1.4 – Continue the City’s commitment to funding early childhood
education, especially for minorities and other underserved populations.
Based on the information provided, the proposal is CONSISTENT with the Memphis 3.0 Comprehensive Plan.
Summary Compiled by: Grayson Vincent, Comprehensive Planning.
Staff Report November 13, 2025
SUP 2025-027 Page 25
25
MAILED PUBLIC NOTICE
Staff Report November 13, 2025
SUP 2025-027 Page 26
26
SIGN AFFIDAVIT
Staff Report November 13, 2025
SUP 2025-027 Page 27
27
Staff Report November 13, 2025
SUP 2025-027 Page 28
28
APPLICATION
Staff Report November 13, 2025
SUP 2025-027 Page 29
29
Staff Report November 13, 2025
SUP 2025-027 Page 30
30
Staff Report November 13, 2025
SUP 2025-027 Page 31
31
OWNER AFFIDAVIT
Staff Report November 13, 2025
SUP 2025-027 Page 32
32
LETTER OF INTENT
Staff Report November 13, 2025
SUP 2025-027 Page 33
33
LETTERS RECEIVED
No letters received at the time of completion of this report.
East Service Center: 6465 Mullins Station Rd; Memphis,
Tennessee
38134
Downtown Service Center: 125 N. Main Street;
Memphis, T
ennessee 38103
website: www.develop901.com
Memphis and Shelby County Division of
Planning and Development
Record Summary for Special Use Permit
Record Detail Information
Record T
ype: Special Use Permit Record Status: Pending
Opened Date:
August 27, 2025
Record Number: SUP 2025-027
Record Name: SUP -Freeman's Little Learners
Expiration Date:
Description of Work: Request for a Special Use Variance Permit to continue educational opportunities at
this site for the past 20 years. Previous occupant was a Group Daycare.
This application request is for a 30 children occupancy Day Care Center.
Parent Record Number:
Address:
1032 HALE RD, MEMPHIS, Tennessee 381
16
Owner Information
Primary Owner Name
Owner Address Owner Phone
Y BCS INVESTMENTS LLC
PO BOX 38895, GERMANT
OWN, TN 38183 9012733265
Parcel Information
077047 00045
Data Fields
PREAPPLICA
TION MEETING
Name of DPD Planner Lucas Skinner
Date of Meeting 07/22/2025
Pre-application Meeting
Type Email
GENERAL PROJECT INFORMATION
Application Type New Special Use Permit (SUP)
List any relevant former Docket / Case
Number(s) related to previous applications on
this site
PD #2002-311
Page 1 of 3 SUP 2025-027
GENERAL PROJECT INFORMATION
Is this application in response to a citation, stop
work order, or zoning letter
No
If yes, please provide a copy of the citation, stop
work order, and/or zoning letter along with any
other relevant information
-
APPROVAL CRITERIA
A) The project will not have a substantial or
undue adverse ef
fect upon adjacent property, the
character of the neighborhood, traffic conditions,
parking, utility facilities and other matters
affecting the public health, safety, and general
welfare
No
B) The project will be constructed, arranged and
operated so as to be compatible with the
immediate vicinity and not interfere with the
development and use of adjacent property in
accordance with the applicable district
regulations
Yes
UDC Sub-Section 9.6.9C Yes
UDC Sub-Section 9.6.9D No
UDC Sub-Section 9.6.9E Yes
UDC Sub-Section 9.6.9F No
GIS INFORMATION
Case Layer BOA1962-013-CO, PD02-311, PD96-361
Central Business Improvement District No
Class C
Downtown Fire District No
Historic District -
Land Use INSTITUTIONAL
Municipality MEMPHIS
Overlay/Special Purpose District -
Zoning R-10
State Route -
Lot 0 52
Subdivision WHITEHAVEN HEIGHTS
Planned Development District -
Wellhead Protection Overlay District No
County Commission District -
City Council District -
City Council Super District -
Contact Information
Page 2 of 3 SUP 2025-027
BRIANNA FREEMANFREEMAN'S LITTLE LEARNERS
(901)273-3265
APPLICANT
Name
Address
Phone
Contact Type
JOE HARRIS
(901)382-2345
ARCHITECT
/ ENGINEER /
SURVEYOR
Name
Address
Phone
Contact Type
EVELYN ROYST
ON
(901)340-1878
REPRESENTATIVE
Name
Address
Phone
Contact Type
Fee Information
Date
AssessedBalanceStatusFeesQuantityFee ItemInvoice #
08/27/20250.00INVOICED500.001Special Use Permit Fee -
5 acres or less (Base Fee)
1673822
08/27/20250.00INVOICED250.001Child Care Center (13+
children)
1673822
08/27/20250.00INVOICED19.501Credit Card Use Fee (.026
x fee)
1673822
Total Fee Invoiced
: $769.50 Total Balance: $0.00
Payment Information
Payment Amount Method of Payment
Credit Card$769.50
Page 3 of 3 SUP 2025-027
CONSTRUCTION CODES CONSULTANTS, LLC
2809 Kirby Parkway, Suite 116-132
MEMPHIS, TN 38119 901.340.1878 : ROYSTONCONSULT@AOL.COM
LETTER OF INTENT
August 25, 2025
To: Division of Planning and Development
125 N, Main St., Rm. 468
Memphis, Tenn. 38103
Site: 1032 Hale Rd., Memphis, Tn. 38116
On behalf of the owner(s)/tenant(s) we are requesting approval for a Special
Use Variance to permit a day care center to serve 30 children, ages 6 weeks to
10 yrs. old at the above site dba Freeman’s Little Learners. The Facility will
operate Monday through Friday, from 6:30 AM to 5:00 PM.
Our mission is to continue the high-quality educational opportunities this site has
maintain for over 20 years. Freeman’s Little Learners take great preparation in
providing STEM projects, physical activity and leadership opportunities for the
after-school programs.
The subject site will provide ingress and egress for drop off and pick up via
circular drive with ADA accessibility per Life Safety codes.
The proposed use request of this site will not alter the site, change the
characteristics, nor have a negative impact on this community.
We appreciate your time and consideration of this application and look forward
to working collaboratively with the appropriate agencies to bring this essential
curriculums to the Whitehaven community.
Sincerely,
Evelyn Royston,
Representative
City Hall – 125 N. Main Street, Suite 468 – Memphis, Tennessee 38103 – (901) 636-6619
November 14, 2025
Brianna Freeman
Freeman's Little Learners
1032 Hale Rd
Memphis, TN 38116
Sent via electronic mail to: bfreeman2037@gmail.com & roystonconsult@aol.com
Case Number: SUP 2025-027
LUCB Recommendation: Approval with conditions
Dear applicant,
On Thursday, November 13 , 20 25, t he Memphis and Shelby County Land Use Control Board
recommended approval of your special use permit application to allow a child care center located
at 1032 Hale Road, subject to the following conditions:
1. A maximum of thirty (30) children are allowed.
2. A final site plan with landscaping shall be submitted subject to administrative review and
approval by the Division of Planning and Development.
3. The subject property and the principal structure must maintain its residential character in
design and scale.
This application will be forwarded, for final action, to the Council of the City of Memphis. The Council
will review your application in a committee meeting prior to vot ing on it in a public hearing. The
applicant or the applicant’s representative(s) shall be in attendance at all meetings and hearings.
It is the applicant’s responsibility to contact the City Council Records Office to determine when the
application is scheduled to be heard at co mmittee and in public session. The City Council Records
Office may be reached at (901) 636-6792.
If for some reason you choose to withdraw your application, a letter should be mailed to the Land
Use and Development Services Department of the Division of Planning and Development at the
address provided above or emailed to the address provided below.
If you have questions regarding this matter, please feel free to contact me at (901) 636-7406 or via
email at nabanita.nira@memphistn.gov.
Letter to Applicant
SUP 2025-027
Page 2 of 2
Respectfully,
Nabanita Nira
Planner II
Land Use and Development Services
Division of Planning and Development
Cc: Evelyn Royston, Construction Code Consultants LLC
File
Memphis City Council
Summary Sheet
SUP 2025-032
RESOLUTION PURSUANT TO CHAPTER 9.6 OF THE MEMPHIS AND SHELBY COUNTY
UNIFIED DEVELOPMENT CODE APPROVING A SPECIAL USE PERMIT AT THE SUBJECT
PROPERTY LOCATED AT 5133 PARK AVENUE, KNOWN AS CASE NUMBER SUP 2025-032
• This item is a resolution with conditions for a special use permit to allow an
expansion of an existing c-store with gas pumps; and
• The item may require future public improvement contracts.
1
LAND USE CONTROL BOARD RECOMMENDATION
At its regular meeting on Thursday, November 13, 20 25, the Memphis and Shelby County Land Use
Control Board held a public hearing on the following application:
CASE NUMBER: SUP 2025-032
LOCATION: 5133 Park Avenue
COUNCIL DISTRICT(S): District 2 and Super District 9 – Positions 1, 2, and 3
OWNER/APPLICANT: Blooming Ventures LLC
REPRESENTATIVE: Brenda Basar, Solomito Land Planning
REQUEST: Special use permit to allow an expansion of an existing c -store with
gas pumps
EXISTING ZONING: Commercial Mixed Use- 1 (CMU- 1)
AREA: +/-1 acre
The following spoke in support: None
The following spoke in opposition: None
The Land Use Control Board reviewed the application and the staff report . A motion was made and
seconded to recommend approval with conditions.
The motion passed by a vote of 7-0-0 on the consent agenda.
Respectfully,
Cc: Committee Members
File
2
SUP 2025-032
CONDITIONS
1. A maximum of one curb cut shall be permitted to South White Station Road and one to Park
Avenue.
2. The existing curb cuts in South White Station Road and Park Avenue closest to the intersection
shall be closed with curb, gutter, and sidewalk.
3. Streetscape Plate Type S -10 modified visa shrubs, and at least 8 feet in width shall be provided
behind the sidewalks adjacent to South White Station Road and Park Avenue.
4. The dumpster location and screening shall meet the requirements of UDC Sub Section 4.6.8B.
5. The convenience store building facing South White Station Road and Park Avenue shall be a
minimum of 60% transparency.
6. Support columns for the fuel canopy shall be sheathed in the same masonry used on the principal
building.
7. An Administrative Site Plan Review (ASPR) shall be submitted and approved by the Division of
Planning and Development following final approval by the Memphis City Council and prior to the
issuance of any building permits or certificates of occupancy.
3
CONCEPT PLAN
Concept Plan
4
SITE PLAN – MAGNIFIED
Concept Plan
RESOLUTION PURSUANT TO CHAPTER 9.6 OF THE MEMPHIS AND SHELBY COUNTY
UNIFIED DEVELOPMENT CODE APPROVING A SPECIAL USE PERMIT AT THE SUBJECT
PROPERTY LOCATED AT 5133 PARK AVENUE, KNOWN AS CASE NUMBER SUP 2025-032
WHEREAS, Chapter 9.6 of the Memphis and Shelby County Unified Development Code, being a
section of the Joint Ordinance Resolution No. 5367, dated August 10, 2010, authorizes the Council of the
City of Memphis to grant a special use permit for certain stated purpos es in the various zoning districts;
and
WHEREAS, Blooming Ventures LLC filed an application with the Memphis and Shelby County
Division of Planning and Development to allow an expansion of an existing c-store with gas pumps; and
WHEREAS, the Division of Planning and Development has received and reviewed the application
in accordance with procedures, objectives, and standards for special use permits as set forth in Chapter 9.6
with regard to the proposed development's impacts upon surrounding propertie s, availability of public
facilities, both external and internal circulation, land use compatibility, and that the design and amenities
are consistent with the public interest; and has submitted its findings and recommendation concerning the
above considerations to the Land Use Control Board; and
WHEREAS, a public hearing in relation thereto was held before the Memphis and Shelby County
Land Use Control Board on November 13 , 20 25, and said Board has submitted its findings and
recommendation concerning the above considerations to the Council of the City of Memphis; and
WHEREAS, the Council of the City of Memphis has reviewed the aforementioned application
pursuant to Tennessee Code Annotated Section 13 -4-202(B)(2)(B)(iii) and has determined that said
development is consistent with the Memphis 3.0 General Plan; and
WHEREAS, the Council of the City of Memphis has reviewed the recommendation of the Land
Use Control Board and the report and recommendation of the Division of Planning and Development and
has determined that said development meets the objectives, standards and criteria for a special use permit,
and said development is consistent with the public interests.
NOW, THEREFORE, BE IT RESOLVED, BY THE COUNCIL OF THE CITY OF
MEMPHIS, that, pursuant to Chapter 9.6 of the Memphis and Shelby County Unified Development Code,
a special use permit is hereby granted for the request use in accordance with the attached conditions.
BE IT FURTHER RESOLVED , that this permit merely authorizes the filing of applications to
acquire a Certificate of Use and Occupancy, or a Building Permit, and other required permits and approvals,
provided that no such Certificate of Use and Occupancy shall be granted until all conditions imposed by
the Council of the City of Memphis have been met.
BE IT FURTHER RESOLVED , that this Resolution take effect from and after the date it shall
have been passed by this Council of the City of Memphis, and become effective as otherwise provided by
law, and thereafter shall be treated as in full force and effect by virtue of passage thereof by the Council of
the City of Memphis, the public welfare requiring same.
CONDITIONS
1. A maximum of one curb cut shall be permitted to South White Station Road and one to Park Avenue.
2. The existing curb cuts in South White Station Road and Park Avenue closest to the intersection shall
be closed with curb, gutter, and sidewalk.
3. Streetscape Plate Type S -10 modified visa shrubs, and at least 8 feet in width shall be provided
behind the sidewalks adjacent to South White Station Road and Park Avenue.
4. The dumpster location and screening shall meet the requirements of UDC Sub Section 4.6.8B.
5. The convenience store building facing South White Station Road and Park Avenue shall be a
minimum of 60% transparency.
6. Support columns for the fuel canopy shall be sheathed in the same masonry used on the principal
building.
7. An Administrative Site Plan Review (ASPR) shall be submitted and approved by the Division of
Planning and Development following final approval by the Memphis City Council and prior to the
issuance of any building permits or certificates of occupancy.
CONCEPT PLAN
Concept Plan
CONCEPT PLAN – MAGNIFIED
Concept Plan
ATTEST:
CC: Division of Planning and Development
– Land Use and Development Services
– Office of Construction Enforcement
Staff Writer: Mahsan Ostadnia E-mail: mahsan.ostadnia@memphistn.gov
AGENDA ITEM: 10 L.U.C.B. MEETING: November 13, 2025
CASE NUMBER: SUP 2025-032
LOCATION: 5133 Park Avenue
COUNCIL DISTRICT: District 2 and Super District 9 – Positions 1, 2, and 3
OWNER/APPLICANT: Blooming Ventures LLC
REPRESENTATIVE: Brenda Basar, Solomito Land Planning
REQUEST: Special use permit to allow an expansion of an existing c-store with gas pumps
EXISTING ZONING: Commercial Mixed Use- 1 (CMU- 1)
CONCLUSIONS
1. The store has operated as a gasoline service station and/or convenience store with fuel sales since 1972.
The current convenience store structure, which was built in 2003, has a ground floor area of 718 square
feet. The proposed site plan includes demolish ing the existing car wash and convenience store (vending
machine) and constructing a new, 3,360 square foot convenience store, while maintaining the existing fuel
canopy and pumps.
2. The 0.755-acre site will have only two access points as they will be closing two of the existing four curb
cuts—from White Station Road and Park Avenue —and is surrounded by a mix of commercial, office, and
residential uses. The plan includes 16 parking spaces, including two ADA -compliant spaces, along with
pedestrian-friendly features such as an 8-foot-wide sidewalk in front of the building and a 6-foot walk along
the eastern side. Landscaping improvements include green buffer areas and planting islands nea r ADA
spaces, and an enclosed dumpster is proposed in the southwest corner of the property.
3. On September 24, 2025, the Board of Adjustment approved Docket BOA 2025 -0089, granting a variance
from Sub -Items 2.6.3J(2)(d)(i) and 2.6.3J(2)(d)(ii) to allow the reconstruction and/or relocation of a
convenience store that does not meet the design requirements. As the property is within the CMU-1 zoning
district, any expansion or addition after January 1, 2021, requires a special use permit under UDC Section
2.6.3J(1)(g). Although the store is a legal nonconforming use, changes proposed after the regulatio n’s
effective date necessitated the applicant obtaining a special use permit for the redevelopment.
4. The granting of this special use permit will not cause substantial detriment to the public good, nor will it
substantially impair the intent and purpose of an adopted plan or the Unified Development Code (UDC),
nor will it be injurious to the neighborhood or the general welfare, and it will be in harmony with the
purpose and intent of the UDC.
CONSISTENCY WITH MEMPHIS 3.0
This proposal is consistent with the Memphis 3.0 General Plan per the land use decision criteria. See further
analysis on pages 23-25 of this report.
RECOMMENDATION:
Approval with conditions
Staff Report November 13, 2025
SUP 2025-032 Page 2
2
LOCATION MAP
Subject property located within the pink circle
SUBJECT PROPERTY
Staff Report November 13, 2025
SUP 2025-032 Page 3
3
PUBLIC NOTICE VICINITY MAP
Subject property highlighted in yellow.
PUBLIC NOTICE DETAILS
In accordance with Sub-Section 9.3.4A of the Unified Development Code, a notice of public hearing is required
to be mailed and signage posted . A total of 93 notices were mailed on October 16, 2025, see page 27 of this
report for a copy of said notice. Additionally, two signs were posted at the subject property, see pages 30-31 of
this report for a copy of the sign affidavit.
NEIGHBORHOOD MEETING
The meeting was held at 6:00 PM on Tuesday, October 28, 2025, 5112 Park Avenue, Memphis, TN 38117 . See
pages 28-29 of this report for a copy of the neighborhood meeting summary.
Staff Report November 13, 2025
SUP 2025-032 Page 4
4
AERIAL
Subject property outlined in yellow.
Staff Report November 13, 2025
SUP 2025-032 Page 5
5
ZONING MAP
Subject property highlighted in yellow.
Staff Report November 13, 2025
SUP 2025-032 Page 6
6
LAND USE MAP
Subject property indicated by a pink star.
Staff Report November 13, 2025
SUP 2025-032 Page 7
7
SITE PHOTOS
View of subject property from Park Avenue.
View of subject property from S White Station Road.
Staff Report November 13, 2025
SUP 2025-032 Page 8
8
View of subject property from above.
View of subject property from above.
Staff Report November 13, 2025
SUP 2025-032 Page 9
9
SURVEY
Staff Report November 13, 2025
SUP 2025-032 Page 10
10
PLOT PLAN
Staff Report November 13, 2025
SUP 2025-032 Page 11
11
SITE PLAN
Staff Report November 13, 2025
SUP 2025-032 Page 12
12
SITE PLAN – MAGNIFIED
Staff Report November 13, 2025
SUP 2025-032 Page 13
13
LANDSCAPE PLAN
Staff Report November 13, 2025
SUP 2025-032 Page 14
14
ELEVATIONS
Staff Report November 13, 2025
SUP 2025-032 Page 15
15
Staff Report November 13, 2025
SUP 2025-032 Page 16
16
CASE REVIEW
Request
The request is a special use permit to allow an expansion of an existing c-store with gas pumps.
Approval Criteria
Staff agrees the approval criteria in regard to special use permits as set out in Section 9. 6.9 of the Unified
Development Code are met.
9.6.9 Approval Criteria
No special use permit or planned development shall be approved unless the following findings are made
concerning the application:
9.6.9A The project will not have a substantial or undue adverse effect upon adjacent property, the
character of the neighborhood, traffic conditions, parking, utility facilities and other matters
affecting the public health, safety, and general welfare.
9.6.9B The project will be constructed, arranged and operated so as to be compatible with the
immediate vicinity and not interfere with the development and use of adjacent property in
accordance with the applicable district regulations.
9.6.9C The project will be served adequately by essential public facilities and services such as streets,
parking, drainage, refuse disposal, fire protection and emergency services, water and sewers; or
that the applicant will provide adequately for such services.
9.6.9D The project will not result in the destruction, loss or damage of any feature determined by the
governing bodies to be of significant natural, scenic or historic importance.
9.6.9E The project complies with all additional standards imposed on it by any particular provisions
authorizing such use.
9.6.9F The request will not adversely affect any plans to be considered (see Chapter 1.9), or violate the
character of existing standards for development of the adjacent properties.
9.6.9G The governing bodies may impose conditions to minimize adverse effects on the neighborhood
or on public facilities, and to ensure compatibility of the proposed development with surrounding
properties, uses, and the purpose and intent of this development code.
9.6.9H Any decision to deny a special use permit request to place, construct, or modify personal wireless
service facilities shall be in writing and supported by substantial evidence contained in a written
record, per the Telecommunications Act of 1996, 47 USC 3 32(c)(7)(B)(iii). The review body may
not take into account any environmental or health concerns.
Site Details
Address:
5133 Park Avenue
Parcel ID:
067004 00003C
Area:
+/-43,560 square feet
Staff Report November 13, 2025
SUP 2025-032 Page 17
17
Description:
The subject property is known as Lot 6 and 7 of Gates Subdivision with a zoning of Commercial Mixed Use - 1
(CMU-1). Per the Assessor’s website, the convenience store was built in 2003 with a ground floor area of 1,707
square feet. The surrounding land uses a mixture of commercial, office space, and residential lots. Additionally,
this lot has two street frontages.
Site Zoning History
The subject property is currently zoned Commercial Mixed Use – 1 (CMU-1). It has continuously operated as a
gasoline service station and/or convenience store with fuel sales since 1972.
At the time of the 1980, Park Avenue – Sea Isle Development Overview Study, the site was zoned C -2. The
property is now zoned CMU -1, making its long-standing use classified as a legal nonconforming use under the
current zoning regulations.
In 2002, the property owner obtained a demolition permit (Permit No. B0888540), as well as a building permit
(Permit No. B0840391) issued on July 25, 2002. Following completion of the permitted work, the owner received
a Certificate of Occupancy for the op eration of a vending machine/convenience store on the subject property.
See page 23 for a copy of the approved Certificate of Occupancy.
On September 24, 2025, the Board of Adjustment approved Docket BOA 2025-0089 from Sub -Items
2.6.3J(2)(d)(i) and 2.6.3J(2)(d)(ii) to allow a reconstructed and/or relocated convenience store that does not
meet the design requirements, see page 26 of this report for said notice of disposition.
Site Plan Review
• The site plan proposes the elimination of the existing car wash structure on site and the construction of
a new 3,360 square foot convenience store (C-Store). The existing fuel canopy and pump area will remain
in its current configuration and size. The overall site area is 0.755 acres. The newly proposed C-Store will
be constructed near the center of the site, facing the parking area.
• Upon reviewing the site plan, the landscape plan does not meet the minimum street tree requirements
outlined by the Unified Development Code (UDC). With approximately 370 feet of frontage, the site
needs Type A trees every 40 feet on center or Type B trees every 30 feet on center. Type C trees would
only be permitted if there are overhead power lines, but based on Google Streetview, there do not
appear to be power lines along the property frontage, so Type C trees are not desirable given their short
height.
• The site plan does not depict the existing vinyl fence along the southern and western property
boundaries. If the fence is to remain, it should be clearly shown and labeled on the updated plan. On the
southern boundary specifically, the fence must remain in place, as its removal would increase the site's
non-conformity with the required buffer adjacent to a single-family residential zoning district.
• The existing fuel canopy will remain in place. It is located approximately 28 feet from both public rights-
of-way (White Station Road and Park Avenue) and has a height of just over 20 feet.
• The site features two access points: one from White Station Road (north side) and one from Park Avenue
Staff Report November 13, 2025
SUP 2025-032 Page 18
18
(east side).
• A total of 16 parking spaces including 2 ADA-accessible spaces are provided on the proposed site plan.
• An 8' wide sidewalk runs along the front of the building, with a 6' walk along the eastern side on site.
• Landscaping includes two islands near the ADA parking spaces on the north side of the building, along
with green buffer areas at the corners and around the property boundaries.
• An enclosed dumpster is located in the southwest corner of the site.
Analysis
The store has operated as a gasoline service station and/or convenience store with fuel sales since 1972. The
current convenience store structure, which was built in 2003, has a ground floor area of 718 square feet. The
proposed site plan includes demolish ing the existing car wash and convenience store (vending machine) and
constructing a new, 3,360 square foot convenience store, while maintaining the existing fuel canopy and pumps.
The 0.755-acre site will have only two access points as they will be closing two of the existing four curb cuts —
from White Station Road and Park Avenue —and is surrounded by a mix of commercial, office, and residential
uses. The plan includes 16 parking spaces, including two ADA -compliant spaces, along with pedestrian-friendly
features such as an 8 -foot-wide sidewal k in front of the building and a 6 -foot walk along the eastern side.
Landscaping improvements include green buffer areas and planting islands nea r ADA spaces, and an enclosed
dumpster is proposed in the southwest corner of the property.
On September 24, 2025, the Board of Adjustment approved Docket BOA 2025 -0089, granting a variance from
Sub-Items 2.6.3J(2)(d)(i) and 2.6.3J(2)(d)(ii) to allow the reconstruction and/or relocation of a convenience store
that does not meet the design requirements. As the property is within the CMU-1 zoning district, any expansion
or addition after January 1, 2021, requires a special use permit under UDC Section 2.6.3J(1)(g). Although the
store is a legal nonconforming use, changes proposed after the regulatio n’s effective date necessitated the
applicant obtaining a special use permit for the redevelopment.
The granting of this special use permit will not cause substantial detriment to the public good, nor will it
substantially impair the intent and purpose of an adopted plan or the Unified Development Code (UDC), nor will
it be injurious to the neighborhood or the general welfare, and it will be in harmony with the purpose and intent
of the UDC.
RECOMMENDATION
Staff recommends approval with conditions.
Conditions
1. A maximum of one curb cut shall be permitted to South White Station Road and one to Park Avenue.
Staff Report November 13, 2025
SUP 2025-032 Page 19
19
2. The existing curb cuts in South White Station Road and Park Avenue closest to the intersection shall be
closed with curb, gutter, and sidewalk.
3. Streetscape Plate Type S-10 modified visa shrubs, and at least 8 feet in width shall be provided behind
the sidewalks adjacent to South White Station Road and Park Avenue.
4. The dumpster location and screening shall meet the requirements of UDC Sub Section 4.6.8B.
5. The convenience store building facing South White Station Road and Park Avenue shall be a minimum
of 60% transparency.
6. Support columns for the fuel canopy shall be sheathed in the same masonry used on the principal
building.
7. An Administrative Site Plan Review (ASPR) shall be submitted and approved by the Division of Planning
and Development following final approval by the Memphis City Council and prior to the issuance of any
building permits or certificates of occupancy.
Staff Report November 13, 2025
SUP 2025-032 Page 20
20
DEPARTMENTAL COMMENTS
The following comments were provided by agencies to which this application was referred:
City/County Engineer: See pages 21-22.
City/County Fire Division: No comments received.
City Real Estate: No comments received.
County Health Department: No comments received.
Shelby County Schools: No comments received.
Construction Code Enforcement: No comments received.
Memphis Light, Gas and Water: No comments received.
Office of Sustainability and Resilience: No comments received.
Office of Comprehensive Planning: See pages 23-25.
Staff Report November 13, 2025
SUP 2025-032 Page 21
21
City Engineer
1. Standard Public Improvement Contract or Right-Of-Way Permit as required in Section 5.5.5 of the Unified
Development Code.
Sewers:
2. City sanitary sewers are available to serve this development.
Roads:
3. The Developer shall be responsible for the repair and/or replacement of all existing curb and gutter along
the frontage of this site as necessary.
4. CONDITION: All existing sidewalks and curb openings along the frontage of this site shall be inspected for
ADA compliance. The developer shall be responsible for any reconstruction or repair necessary to meet
City standards.
a. ADA Ramp non-conforming (no landing)
Traffic Control Provisions:
5. The developer shall provide a traffic control plan to the city engineer that shows the phasing for each
street frontage during demolition and construction of curb gutter and sidewalk. Upon completion of
sidewalk and curb and gutter improvements, a minimum 5 foot wide pedestrian pathway shall be provided
throughout the remainder of the project. In the event that the existing right of way width does not allow
for a 5 foot clear pedestrian path, an exception may be considered.
6. Any closure of the right of way shall be time limited to the active demolition and construction of sidewalks
and curb and gutter. Continuous unwarranted closure of the right of way shall not be allowed for the
duration of the project. The developer shall provide on the traffic control plan, the time needed per phase
to complete that portion of the work. Time limits will begin on the day of closure and will be monitored by
the Engineering construction inspectors on the job.
7. The developer’s engineer shall submit a Trip Generation Report that documents the proposed land use,
scope and anticipated traffic demand associated with the proposed development. A detailed Traffic Impact
Study will be required when the accepted Trip Generation Report indicates that the number for projected
trips meets or exceeds the criteria listed in Section 210-Traffic Impact Policy for Land Development of the
City of Memphis Division of Engineering Design and Policy Review Manual. Any required Traffic Impact
Study will need to be formally approved by the City of Memphis, Traffic Engineering Department.
Curb Cuts/Access:
8. The City Engineer shall approve the design, number, and location of curb cuts.
9. CONDITION: Any existing nonconforming curb cuts shall be modified to meet current City Standards or
closed with curb, gutter, and sidewalk.
a. Sidewalk needs to be brought to conformance ~100LF
b. 3 Drive Aprons need to be repaired
Drainage:
10. A grading and drainage plan for the site shall be submitted to the City Engineer for review and approval
Staff Report November 13, 2025
SUP 2025-032 Page 22
22
prior to recording of the final plat.
11. Drainage improvements, including possible on-site detention, shall be provided under a Standard
Subdivision contract in accordance with Unified Development Code and the City of Memphis/Shelby
County Storm Water Management Manual.
12. Drainage data for assessment of on-site detention requirements shall be submitted to the City Engineer.
13. The following note shall be placed on the final plat of any development requiring on-site storm water
detention facilities: The areas denoted by "Reserved for Storm Water Detention" shall not be used as a
building site or filled without first obtaining written permission from the City and/or County Engineer. The
storm water detention systems located in these areas, except for those parts located in a public drainage
easement, shall be owned and maintained by the property owner and/or property owners' association.
Such maintenance shall be performed so as to ensure that the system operates in accordance with the
approved plan on file in the City and/or County Engineer's Office. Such maintenance shall include, but not
be limited to removal of sedimentation, fallen objects, debris and trash, mowing, outlet cleaning, and
repair of drainage structures.
14. The developer should be aware of his obligation under 40 CFR 122.26(b)(14) and TCA 69-3-101 et. seq. to
submit a Notice of Intent (NOI) to the Tennessee Division of Water Pollution Control to address the
discharge of storm water associated with the clearing and grading activity on this site.
General Notes:
Development is located within a sensitive drainage basin and requires engineering review of any onsite
grading and drainage.
Staff Report November 13, 2025
SUP 2025-032 Page 23
23
Office of Comprehensive Planning
This summary is being produced in response to the following application to support the Land Use and
Development Services Department in their recommendation:
Site Address/Location: 5133 Park Ave
Overlay District/Historic District/Flood Zone: Not in an Overlay District, Historic District, or Flood Zone
Future Land Use Designation: Low Intensity Commercial and Services (CSL)
Street Type: Avenue & Parkway
The applicant is requesting to allow expansion of an existing convenience store with gas pumps.
The following information about the land use designation can be found on pages 76 – 122:
1. Future Land Use Planning Map
Red polygon indicates the application site on the Future Land Use Map.
2. Land Use Description/Intent
Low Intensity Commercial and Service (CSL) areas are
typically not associated with anchors. These areas may
include neighborhood supporting commercial uses such as
retail sales and services, offices, restaurants, funeral
services, small-scale recreation, social service institutions,
and occasional upper -story residential. Graphic portrayal
of CSL is to the right.
Staff Report November 13, 2025
SUP 2025-032 Page 24
24
“CSL” Form & Location Characteristics
Commercial and services uses, 1-4 stories height
“CSL” Zoning Notes
Generally compatible with the following zone districts: CMU-1 without frontage requirements, OG, SDBP in
accordance with Form and characteristics listed above.
Existing, Adjacent Land Use and Zoning
Existing Land Use and Zoning: Commercial; CMU-1
Adjacent Land Use and Zoning: Commercial, Single-Family; R-6, OG, CMU-3
Overall Compatibility: This requested use is compatible with the land use description/intent, form & location
characteristics, zoning notes, and existing, adjacent land use to allow an expansion of an existing convenience
store with gas pumps
Degree of Change Map
Red polygon denotes the proposed site on the Degree of Change Map. There is no Degree of Change.
3. Degree of Change Description
N/A
4. Objectives/Actions Consistent with Goal 1, Complete, Cohesive, Communities
N/A
5. Pertinent Sections of Memphis 3.0 that Address Land Use Recommendations.
Objective 6.4: Support growth and exapnsion of local minority-owned businesses.
Staff Report November 13, 2025
SUP 2025-032 Page 25
25
Consistency Analysis Summary
The applicant is requesting to allow expansion of an existing convenience store with gas pumps.
This requested use is compatible with the land use description/intent, form & location characteristics, zoning
notes, and existing, adjacent land use to allow an expansion of an existing convenience store with gas pumps
Based on the information provided, the proposal is CONSISTENT with the Memphis 3.0 Comprehensive Plan.
Staff Report November 13, 2025
SUP 2025-032 Page 26
26
NOTIC OF DISPOSITION (BOA 2025-0089)
Staff Report November 13, 2025
SUP 2025-032 Page 27
27
MAILED PUBLIC NOTICE
Staff Report November 13, 2025
SUP 2025-032 Page 28
28
NEIGHBORHOOD MEETING SUMMARY
Staff Report November 13, 2025
SUP 2025-032 Page 29
29
Staff Report November 13, 2025
SUP 2025-032 Page 30
30
SIGN AFFIDAVIT
Staff Report November 13, 2025
SUP 2025-032 Page 31
31
Staff Report November 13, 2025
SUP 2025-032 Page 32
32
APPLICATION
Staff Report November 13, 2025
SUP 2025-032 Page 33
33
Staff Report November 13, 2025
SUP 2025-032 Page 34
34
Staff Report November 13, 2025
SUP 2025-032 Page 35
35
OWNER AFFIDAVIT
Staff Report November 13, 2025
SUP 2025-032 Page 36
36
LETTER OF INTENT
Staff Report November 13, 2025
SUP 2025-032 Page 37
37
Staff Report November 13, 2025
SUP 2025-032 Page 38
38
Staff Report November 13, 2025
SUP 2025-032 Page 39
39
Staff Report November 13, 2025
SUP 2025-032 Page 40
40
LETTERS RECEIVED
No letters received at the time of completion of this report.
East Service Center: 6465 Mullins Station Rd; Memphis,
Tennessee
38134
Downtown Service Center: 125 N. Main Street;
Memphis, T
ennessee 38103
website: www.develop901.com
Memphis and Shelby County Division of
Planning and Development
Record Summary for Special Use Permit
Record Detail Information
Record T
ype: Special Use Permit Record Status: Pending
Opened Date:
October 2, 2025
Record Number: SUP 2025-032
Record Name: Park and White Station SUP
Expiration Date:
Description of Work: Application for Special Use Permit to allow an existing convivence store with the sale
of gasoline.
Parent Record Number:
Address:
5133 PARK
AVE, MEMPHIS 38117
Owner Information
Primary Owner Name
Owner Address Owner Phone
Y RIVAL
TO MICHAEL A REVOCABLE LIVING TRUST
1420 STONEBROOK AVE, MEMPHIS, TN 38116
Parcel Information
067004 00003C
Data Fields
PREAPPLICA
TION MEETING
Name of DPD Planner Masah Ostadnia
Date of Meeting 09/19/2025
Pre-application Meeting
Type Email
GENERAL PROJECT INFORMATION
Application Type New Special Use Permit (SUP)
List any relevant former Docket / Case
Number(s) related to previous applications on
this site
BOA 2025-0089
Is this application in response to a citation, stop No
Page 1 of 3 SUP 2025-032
GENERAL PROJECT INFORMATION
work order, or zoning letter
If yes, please provide a copy of the citation, stop
work order, and/or zoning letter along with any
other relevant information
-
APPROVAL CRITERIA
A) The project will not have a substantial or
undue adverse ef
fect upon adjacent property, the
character of the neighborhood, traffic conditions,
parking, utility facilities and other matters
affecting the public health, safety, and general
welfare
SEE ATTACHED
B) The project will be constructed, arranged and
operated so as to be compatible with the
immediate vicinity and not interfere with the
development and use of adjacent property in
accordance with the applicable district
regulations
SEE ATTACHED
UDC Sub-Section 9.6.9C SEE ATTACHED
UDC Sub-Section 9.6.9D SEE ATTACHED
UDC Sub-Section 9.6.9E SEE ATTACHED
UDC Sub-Section 9.6.9F SEE ATTACHED
GIS INFORMATION
Case Layer -
Central Business Improvement District No
Class C
Downtown Fire District No
Historic District -
Land Use COMMERCIAL
Municipality MEMPHIS
Overlay/Special Purpose District -
Zoning CMU-1
State Route -
Lot 6 & 7
Subdivision GATES
Planned Development District -
Wellhead Protection Overlay District No
County Commission District -
City Council District -
City Council Super District -
Contact Information
Page 2 of 3 SUP 2025-032
HUSSEIN UMLANI
(404)786-7955
APPLICANT
Name
Address
Phone
Contact Type
BRENDA SOLOMIT
O BASAR
(901)569-0310
REPRESENTATIVE
Name
Address
Phone
Contact Type
Fee Information
Date AssessedBalanceStatusFeesQuantityFee ItemInvoice #
10/02/20250.00INVOICED500.001Special Use Permit Fee -
5 acres or less (Base Fee)
1682133
10/02/20250.00INVOICED13.001Credit Card Use Fee (.026
x fee)
1682133
Total Fee Invoiced
: $513.00 Total Balance: $0.00
Payment Information
Payment Amount Method of Payment
Credit Card$513.00
Page 3 of 3 SUP 2025-032
P A R K
A V E N U E
( 90' PUBLIC R.O.W. )
W
H
I
T
E
S
T
A
T
I
O
N
R
O
A
D
(80
'
PUBLIC
R
.O
.W
.)
8' WALK
6' WALK
11
5
84.00'40.00'
0.755 Acres
16 Parking Spaces Prov.
5 Existing Pumps
PROPOSED C-STORE
3,360 S.F.
EXISTING
CANOPY - PUMPS
P A R K
A V E N U E
( 90' PUBLIC R.O.W. )
W
H
I
T
E
S
T
A
T
I
O
N
R
O
A
D
(80
'
PUBLIC
R
.O
.W
.)
DWG. NAME: 25019-M02.dwg
Site Plan
M E M P H I S, T E N N E S S E E
5133 Park Avenue
July 18, 2025
50'25'
SCALE: 1"=50'NORTH
0
EF-1 EF-1
BR-1BR-1 STA-1
BR-1
MC-1
AL-1
EF-1 EF-1
STA-1
BR-1
ARRISCRAFT - ASH - STACK
ALUMINUM STOREFRONT CLEAR FINISH
STA-1 -
AL-1 -
METAL CANOPY- ALUMINUM CLEAR FINISHMC-1 -
BRICKCRAFT SHADOWSTONE-QUEENBR-1 -
FINISH SCHEDULE
EIFS 1- STO ESSENCE - COTTON 32138EF-1 -
A7
EF-1
BR-1
EF-1
BR-1
ARRISCRAFT - ASH - STACK
ALUMINUM STOREFRONT CLEAR FINISH
STA-1 -
AL-1 -
METAL CANOPY- ALUMINUM CLEAR FINISHMC-1 -
BRICKCRAFT SHADOWSTONE-QUEENBR-1 -
FINISH SCHEDULE
EIFS 1- STO ESSENCE - COTTON 32138EF-1 -
A7.1
SOLOMITO brenda@solomitolandplanning.com I 901.755.7495
October 2, 2025
Brett Ragsdale, AIA
Zoning Administrator
Memphis & Shelby County
Division of Planning and Development
City Hall, 125 N. Main St., Ste. 468
Memphis, TN 38103
RE: Application for Special Use Permit
5133 Park Avenue
Dear Brett:
I am pleased to submit an application for a Special Use Permit on behalf of RIVALTO MICHAEL A
REVOCABLE LIVING TRUST, owners of the property and current applicant Blooming Ventures, LLC. The
property has changed hands several times over the years until the current property owner purchased the
property in 2002.
The property is located at 5133 Park Avenue, the southwest corner of Park Avenue and White Station
Road. According to the current Zoning Atlas, the property is zoned Commercial Mixed Use (CMU-1) and
has consistently operated as a gasoline service station and/or convenience store with the sale of gasoline
since 1972. Best indicators and proof of use are from the submitted aerial photographs.
On September 24, 2025, the Board of Adjustment approved our application for relief based upon there
being Exceptional conditions.
This imparts upon the owner the following hardship or practical difficulty under the strict adherence to the
Code: The new convenience store cannot meet the architectural compatibility requirements of Sub-Item
2.6.3J(2)(d)(i) and 2.6.3J(2)(d)(ii).
Approval with the following Conditions
1. Should no special use permit be approved by the Memphis City Council by September 24, 2026, this
variance shall be rendered null and void.
2. Support columns for a fuel canopy shall be sheathed in the same masonry used on the principal
building.
3. Any change or deviation from the site plan upon the determination of the Zoning Administrator shall
be submitted to the Board of Adjustment for review and approval or administrative review and
approval by the Division of Planning and Development.
1
Plans to be Considered
As a Plan to be considered, The Park Avenue - Sea Isle Development Overview Study of 1980 indicated
this property was zoned C-2 and did not recommend any changes to the zoning at that time. It is unclear
when the property was down zoned to CMU-1. But for the zoning change, this site could be treated as a
simple legal non-conforming use.
With the confirmation of this legal non-conforming use, the purpose of this application is to seek a Special
Use Permit to legitimize this use and obtain approval of a new site plan. The current operation contains a
self-serve convenience store, gasoline sales, car wash, and a storage building totaling almost 2,000 sf as
illustrated on the survey.
This application seeks to:
1. Eliminate the car wash entirely.
2. Construct a new 3,360 sf building and associated parking.
3. The fuel canopy will remain the same size and in the same location.
4. Comply with the Board of Adjustment Conditions of Approval.
2
Special Use Permit Approval Criteria - In conformance with the Approval Criteria established in the
Unified Development Code,
The project will not have a substantial or undue adverse effect upon adjacent property, the character of
the neighborhood, traffic conditions, parking, utility facilities and other matters affecting the public
health, safety, and general welfare:
• The subject property has continually operated as a convenience store with the sale of gasoline since
1972 without interruption. Since the 1980s, the site has maintained the same general layout as we
see today. Specifically, the large underground tanks and gas pump locations are key to the use of
the site. The existing non-conforming canopy will remain; however, the other structures and car
wash will be removed to make way for a new building that will conform to the associated Variances
as approved by the Board of Adjustment on September 24, 2025.
The project will be constructed, arranged and operated so as to be compatible with the immediate
vicinity and not interfere with the development and use of adjacent property in accordance with the
applicable district regulations:
• Again, based upon the attached aerial photos, the property has maintained the same form over the
decades. With this redevelopment, the site will be improved by the elimination of the car wash and
construction of the attractive masonry building. The corner location and the surrounding uses have
supported this use since 1972. The strict application of the regulations would compound the undue
hardship when redeveloping this site.
The project will be served adequately by essential public facilities and services such as streets, parking,
drainage, refuse disposal, fire protection and emergency services, water and sewers; or that the
applicant will provide adequately for such services:
• All public facilities and support services are in place.
The project will not result in the destruction, loss or damage of any feature determined by the governing
bodies to be of significant natural, scenic or historic importance:
• No feature determined by the governing bodies to be of significant natural, scenic or historic
importance exists on the site.
The project complies with all additional standards imposed on it by any particular provisions authorizing
such use:
• With the approval by the Board of Adjustment, this project will comply with the provisions of a
granted Special Use Permit and other applicable regulations.
3
The request will not adversely affect any plans to be considered (see Chapter 1.9), or violate the character of
existing standards for development of the adjacent properties:
• The Park Avenue - Sea Isle Development Overview Study of 1980 indicates the property was zoned
CMU-2 and a convenience store with the sale of gasoline was permitted by right. The Overview Study did
not recommend any changes in zoning for this site. A rezoning occurred after 1980 and created a legal
non-conforming use on a property that has historically been zoned for this use. The applicant purchased
the property in 2002, and these nonconformities existed at that time. The property is also adjacent to
and near other automotive service uses in the area.
The practical difficulty for the applicant lies in the physical condition of the property and the nonconforming
status. Any renovations or other improvements that expand or prolong the non-conforming use are
prohibited without Special Use approval. Additionally, it is highly unlikely that the property will be used for
any other purpose.
As always, thank you very much for your time and attention to this matter. Please do not hesitate to call with
any questions or comments.
Sincerely,
SOLOMITO LAND PLANNING
Brenda
Brenda Solomito Basar
Land Planner
4
Source: City of Memphis website. First collected Oct 27, 2026.