Packet
Williamson County · Williamson County · meeting of May 14, 2026 · Agenda packets
Open the original document More from Williamson County
Text
Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.
May 2026 Planning Commission Agenda
01 MAY AGENDA.PDF
May 2026 Planning Commission Online Packet
PC PACKET 5-14-2026 - 1 OF 2.PDF
PC PACKET 5-14-2026 - 2 OF 2.PDF
May 2026 Planning Commission Online Packet
PC PACKET 5-14-2026 - 1 OF 2.PDF
PC PACKET 5-14-2026 - 2 OF 2.PDF
MAY 2026 PC MINUTES
02 MAY 2026 PC MINUTES.PDF
1.
Documents:
2.
Documents:
3.
Documents:
3.I.
Documents:
AGENDA
WILLIAMSON COUNTY REGIONAL PLANNING COMMISSION
Williamson County Administrative Complex
May 14, 2026 at 5:30 p.m.
PUBLIC COMMENTS:
Public comment is permitted on Agenda items – sign-in prior to the meeting is required.
MINUTES:
1. Approval of April 9, 2026 Minutes
CONSENT AGENDA:
2. Consent Agenda
BONDS:
3. Arrington Woods, Section 1 – Performance Bond for Landscaping located off
Nolensville Road.
4. Arrington Woods, Section 1 – Performance Bond for Roads, Drainage and Erosion
locate off Nolensville Road.
5. Daventry, Section 1 - Maintenance Bond for Roads, Drainage and Erosion Control
located off Tullous Road.
6. Daventry, Section 3 - Maintenance for Roads, Drainage and Erosion Control located
off Tullous Road.
7. Enclave at Dove Lake, Section 2 – Maintenance Bond for Roads, Drainage and Erosion
Control located off Nolensville Road.
8. Fiddlers Glen/Cox Ladd – Maintenance Bond for Landscaping located off Murfreesboro
Road.
9. Fiddlers Glen, Section 1 – Performance Bond for Roads, Drainage and Erosion Control
located off Murfreesboro Road.
10. Hardeman Springs, Section 1 – Maintenance Band for Roads, Drainage and Erosion
Control located off Murfreesboro Road.
11. Hart’s Landmark – Maintenance Bond for Sewer located off North Chapel Road.
12. High Park Hill Amenity – Performance Bond for Landscaping located off Murfreesboro
Road.
13. High Park Hill Amenity – Performance Bond for Wastewater Collection System located
off Murfreesboro Road.
14. High Park Hill, Section 4 – Performance Bond for Roads, Drainage and Erosion Control
located off Murfreesboro Road.
15. Reeds Vale Amenity – Performance Bond for Landscaping located off Lampkins Bridge
Road.
16. Reeds Vale, Section 1 – Maintenance Bond for Roads, Drainage and Erosion Control
located off Lampkins Bridge Road.
17. Reeds Vale, Section 2 – Performance Bond for Landscaping located off Lampkins
Bridge Road.
18. St. Barbara’s Coptic Church – Maintenance Bond for Landscaping located off
Clovercroft Road.
19. St. Marlo, Section 3 – Maintenance Bond for Wastewater Collection System located
off Long Lane.
20. Taliaferro Subdivision – Performance Bond for Landscaping located off Taliaferro
Road.
21. Taliaferro Subdivision – Performance Bond for Roads, Drainage and Erosion Control
located off Taliaferro Road.
22. Vista Creek – Performance Bond for Landscaping located off Old Hillsboro Road.
OLD BUSINESS:
23. Terravista Roads, Drainage, and Erosion Control Bond Update.
24. Preliminary Plat Review for Lot 1 of the Larry U. Turner Property LLE Subdivision,
containing 1 lot on 20.33 acres located off Carl Road in the 5th Voting District (1 -
2026-301).
25. Concept Plan Review for Wilson Branch Farms Subdivision (AKA 3036 Old
Murfreesboro Road), containing 28 lots on 34.15 acres located off Old Murfreesboro
Road in the 5th Voting District (1-2025-213).
26. Preliminary Plat Review for Chestnut Hill Farms LLE Subdivision, containing 5 lots on
28.5 acres located off Whippoorwill Drive in the 1st Voting District (1 -2025-324).
27. Preliminary Plat Review for Joybelle Estates Subdivis ion, containing 12 lots on 110.1
acres located off Eudailey Covington Road in the 2 nd Voting District (1-2026-304).
28. Preliminary Plat Review for Creekbend Manor LLE Subdivision (AKA 8828 Horton
Highway), containing 5 lots on 28.01 acres located off Horton Highway in the 2 nd
Voting District (1-2025-334).
NON-RESIDENTIAL SITE PLANS:
29. Site Plan Review for Arbors at Leipers Fork Subdivision Amenity Center, on 51.41 acres
located off Hargrove Road in the 1st Voting District (5-2026-002).
PRELIMINARY PLATS:
30. Preliminary Plat Review for Dodd Family Revocable Living Trust Subdivision,
containing 1 lot on 32.12 acres located off Taliaferro Road in the 5th Voting District
(1-2026-305).
31. Preliminary Plat Review for Haley Valley LLE Subdivision, containing 5 lots on 25.12
acres located off Murfreesboro Road in the 5 th Voting District (1-2026-307).
FINAL PLATS:
32. Final Plat Review for Foster Subdivision Family Subdivision, containing 1 lot on 1.40
acres located off of Taliaferro Road in the 5th Voting District (1-2026-409 ).
33. Final Plat Review for Lot 201 of Artesian Acres Subdivision, Section 2, containing 1 lot
on 5 acres located off Artesian Drive in the 5 th Voting District (1-2026-405).
34. Final Plat Review for King’s Chapel, Section 16, containing 1 lot on 0.78 acres located
off Murfreesboro Road in the 5th Voting District (1-2026-406).
35. Final Plat Review for High Park Hill, Section 5, containing 40 lots on 59.86 acres
located off Murfreesboro Road in the 5th Voting District (1-2026-407).
36. Final Plat Review for The Arbors at Leipers Fork, Section 2, containing 16 lots on 133
acres located off Hargrove Road in the 1st Voting District (1-2026-408).
ORDER OF BUSINESS
WILLIAMSON COUNTY REGIONAL PLANNING COMMISSION
1. Call to order
2. Roll Call
3.
Announcements
4.
Public Comments
5.
Consideration of Minutes
6.
Consideration of Consent Agenda
7.
Presentation of Agenda Items for Discussion and Action
8. Other Business
AGENDA
WILLIAMSON COUNTY REGIONAL PLANNING COMMISSION
Williamson County Administrative Complex
May 14, 2026 at 5:30 p.m.
PUBLIC COMMENTS:
Public comment is permitted on Agenda items – sign-in prior to the meeting is required.
MINUTES:
1. Approval of April 9, 2026 Minutes
CONSENT AGENDA:
2. Consent Agenda
BONDS:
3. Arrington Woods, Section 1 – Performance Bond for Landscaping located off
Nolensville Road.
4. Arrington Woods, Section 1 – Performance Bond for Roads, Drainage and Erosion
locate off Nolensville Road.
5. Daventry, Section 1 - Maintenance Bond for Roads, Drainage and Erosion Control
located off Tullous Road.
6. Daventry, Section 3 - Maintenance for Roads, Drainage and Erosion Control located
off Tullous Road.
7. Enclave at Dove Lake, Section 2 – Maintenance Bond for Roads, Drainage and Erosion
Control located off Nolensville Road.
8. Fiddlers Glen/Cox Ladd – Maintenance Bond for Landscaping located off Murfreesboro
Road.
9. Fiddlers Glen, Section 1 – Performance Bond for Roads, Drainage and Erosion Control
located off Murfreesboro Road.
10. Hardeman Springs, Section 1 – Maintenance Band for Roads, Drainage and Erosion
Control located off Murfreesboro Road.
11. Hart’s Landmark – Maintenance Bond for Sewer located off North Chapel Road.
12. High Park Hill Amenity – Performance Bond for Landscaping located off Murfreesboro
Road.
13. High Park Hill Amenity – Performance Bond for Wastewater Collection System located
off Murfreesboro Road.
14. High Park Hill, Section 4 – Performance Bond for Roads, Drainage and Erosion Control
located off Murfreesboro Road.
15. Reeds Vale Amenity – Performance Bond for Landscaping located off Lampkins Bridge
Road.
16. Reeds Vale, Section 1 – Maintenance Bond for Roads, Drainage and Erosion Control
located off Lampkins Bridge Road.
17. Reeds Vale, Section 2 – Performance Bond for Landscaping located off Lampkins
Bridge Road.
18. St. Barbara’s Coptic Church – Maintenance Bond for Landscaping located off
Clovercroft Road.
19. St. Marlo, Section 3 – Maintenance Bond for Wastewater Collection System located
off Long Lane.
20. Taliaferro Subdivision – Performance Bond for Landscaping located off Taliaferro
Road.
21. Taliaferro Subdivision – Performance Bond for Roads, Drainage and Erosion Control
located off Taliaferro Road.
22. Vista Creek – Performance Bond for Landscaping located off Old Hillsboro Road.
OLD BUSINESS:
23. Terravista Roads, Drainage, and Erosion Control Bond Update.
24. Preliminary Plat Review for Lot 1 of the Larry U. Turner Property LLE Subdivision,
containing 1 lot on 20.33 acres located off Carl Road in the 5th Voting District (1 -
2026-301).
25. Concept Plan Review for Wilson Branch Farms Subdivision (AKA 3036 Old
Murfreesboro Road), containing 28 lots on 34.15 acres located off Old Murfreesboro
Road in the 5th Voting District (1-2025-213).
26. Preliminary Plat Review for Chestnut Hill Farms LLE Subdivision, containing 5 lots on
28.5 acres located off Whippoorwill Drive in the 1st Voting District (1 -2025-324).
27. Preliminary Plat Review for Joybelle Estates Subdivis ion, containing 12 lots on 110.1
acres located off Eudailey Covington Road in the 2 nd Voting District (1-2026-304).
28. Preliminary Plat Review for Creekbend Manor LLE Subdivision (AKA 8828 Horton
Highway), containing 5 lots on 28.01 acres located off Horton Highway in the 2 nd
Voting District (1-2025-334).
NON-RESIDENTIAL SITE PLANS:
29. Site Plan Review for Arbors at Leipers Fork Subdivision Amenity Center, on 51.41 acres
located off Hargrove Road in the 1st Voting District (5-2026-002).
PRELIMINARY PLATS:
30. Preliminary Plat Review for Dodd Family Revocable Living Trust Subdivision,
containing 1 lot on 32.12 acres located off Taliaferro Road in the 5th Voting District
(1-2026-305).
31. Preliminary Plat Review for Haley Valley LLE Subdivision, containing 5 lots on 25.12
acres located off Murfreesboro Road in the 5 th Voting District (1-2026-307).
FINAL PLATS:
32. Final Plat Review for Foster Subdivision Family Subdivision, containing 1 lot on 1.40
acres located off of Taliaferro Road in the 5th Voting District (1-2026-409 ).
33. Final Plat Review for Lot 201 of Artesian Acres Subdivision, Section 2, containing 1 lot
on 5 acres located off Artesian Drive in the 5 th Voting District (1-2026-405).
34. Final Plat Review for King’s Chapel, Section 16, containing 1 lot on 0.78 acres located
off Murfreesboro Road in the 5th Voting District (1-2026-406).
35. Final Plat Review for High Park Hill, Section 5, containing 40 lots on 59.86 acres
located off Murfreesboro Road in the 5th Voting District (1-2026-407).
36. Final Plat Review for The Arbors at Leipers Fork, Section 2, containing 16 lots on 133
acres located off Hargrove Road in the 1st Voting District (1-2026-408).
MINUTES OF THE
WILLIAMSON COUNTY REGIONAL PLANNING COMMISSION
MEETING OF APRIL 9, 2026
MEMBERS PRESENT
Brian Clifford
Don Crohan
Sharon Hatcher
Steve Lane
Jessica Lucyshyn
Keith McCord
Eddie Sanders
STAFF PRESENT
Michael Matteson, Community Development
Director
Aaron V. Holmes, Planning Director
Floyd Heflin, County Engineer
Michael Scott, Ass’t to County Engineer
Kristi Ransom, County Attorney
Lincoln Sweet, Senior Planner
Charlie Waldrop, Planning Technician
Lania Escobar, Office Manager
The Williamson County Regional Planning Commission met in regular session Thursday,
April 9, 2026, at 5:30 p.m. in the Auditorium of the Williamson County Administrative
Complex. Commissioners Bailey, Baldree, Kennedy, McCoy and Richter were unable to
attend.
Vice-Chairman Crohan called the meeting to order and took Roll Call. A quorum was
present.
Vice-Chairman Crohan asked if there were any announcements.
Mr. Holmes announced the following:
• Items 28, 29, 33 and 34 are on the Consent Agenda for Deferral; and
• Public Meeting to present the Draft of the Table of Uses and the Draft Regulations
for the Arrington Village will be held next Wednesday, April 15 th at 6:00 PM at
Arrington Elementary School. The Draft of the Table of Uses and the Draft
Regulations can be found on the County’s website. The flyer and the Drafts are
on the desks.
PUBLIC COMMENTS:
No one signed up to speak.
CONSIDERATION OF MARCH 19, 2026 MINUTES:
Vice-Chairman Crohan asked if there were comments or questions on the Minutes.
Hearing none, he asked for a motion.
Commissioner Lane made a motion to approve the March 19, 2026 Minutes. The motion
was seconded by Commissioner Sanders. The motion was unanimously approved.
CONSENT AGENDA:
Commissioners Hatcher and McCord recused themselves from the Consent Agenda.
Vice-Chairman Crohan asked if there were any items that needed to be discussed
separately. Hearing none, he asked for a motion to accept the Consent Agenda as a
whole.
Williamson County Planning Commission
Meeting of April 20, 2026
Page 2 of 10
Commissioner Sanders made a motion to approve the Consent Agenda per Staff
recommendations. Commissioner Clifford seconded the motion. The motion was
unanimously approved.
BONDS:
3. The Arbors at Leipers Fork – Performance Bond for Water (HB&TS) located off
Hargrove Road. - $536,000
Recommendation: HB&TS Utility District requests this be extended in the current
amount for a period of two (2) months. Staff concurs with this request.
4. The Arbors at Leipers Fork – Performance Bond for Roads, Drainage and Erosion
Control located off Hargrove Road. - $703,000
Recommendation: Reduce to the amount of $469,000 for a period of one (1) year.
5. Arrington Ridge, Section 1 – Maintenance Bond for Roads, Drainage and Erosion
Control located off Cox Road. - $250,000
Recommendation: Extend in the current amount for a period of one (1) year.
6. Blackberry Ridge - Maintenance Bond for Roads, Drainage and Erosion located off
Bending Chestnut Road. - $250,000
Recommendation: Extend in the current amount for a period of one (1) year.
7. Conduit Church – Performance Bond for Landscaping located off Lewisburg Pike. -
$12,850
Recommendation: Extend in the current amount for a period of six (6) months to
allow for replanting.
8. Fairhaven – Performance Bond for Landscaping located off Bethesda Road. - $261,866
Recommendation: Extend in the current amount for six (6) months to allow for
completion.
9. Fiddlers Glen, Section 1 – Performance Bond for Wastewater Collection System located
off Murfreesboro Road. - $178,000
Recommendation: Extend in the current amount for a period of one (1) year.
10. Fiddlers Glen, Section 2 – Performance Bond for Roads, Drainage and Erosion Control
located off Murfreesboro Road. - $553,000
Recommendation: Reduce to the amount of $415,000 for a period of one (1) year.
11. Fiddlers Glen, Section 2 – Performance Bond for Wastewater Collection System
located off Murfreesboro Road.- $60,000
Recommendation: Extend in the current amount for a period of one (1) year.
12. High Park Hill, Section 2 – Maintenance Bond for Wastewater Collection System
located off Murfreesboro Road. - $28,110
Recommendation: Release the bond.
13. Homes at Mulberry Springs Wastewater – Performance Bond for Landscaping located
off Taliaferro Road. - $55,500
Recommendation: Extend for a period of six (6) months to allow for completion.
14. Homes at Mulberry Springs Wastewater – Performance Bond for Wastewater
Treatment and Disposal System located off Taliaferro Road. - $100,200
Recommendation: Extend in the current amount for a period of one (1) year.
Williamson County Planning Commission
Meeting of April 20, 2026
Page 3 of 10
15. Lifepoint Church – Performance Bond for Landscaping located off Clovercroft Road. -
$159,225
Recommendation: Extend for a period of six (6) months to allow for completion.
16. Reeds Vale, Section 4 - Performance Bond for Landscaping located off Lampkins
Bridge Road. - $123,252
Recommendation: Extend for a period of six (6) months to allow for completion.
17. Reeds Vale, Section 4 – Performance Bond for Wastewater Collection System located
off Lampkins Bridge Road. - $360,045.50
Recommendation: Reduce to Maintenance in the amount of $108,013.65 for a period
of two (2) years.
18. Reeds Vale, Section 4 – Performance Bond for Roads, Drainage and Erosion Control
located off Lampkins Bridge Road. - $2,800,000
Recommendation: Reduce to the amount of $1,400,000 for a period of one (1) year.
19. Southall Rural Retreat Wastewater Area – Maintenance Bond for Wastewater
Treatment and Disposal System located off Carters Creek Pike. - $124,700
Recommendation: Release the bond.
20. Southall Rural Retreat Wastewater Area – Maintenance Bond for Wastewater
Collection System located off Carters Creek Pike. - $122,700
Recommendation: Release the bond.
21. Terravista, Section 1 – Maintenance Bond for Roads, Drainage and Erosion Control
located off Long Lane. - $950,000
Recommendation: Extend in the current amount for a period of one (1) year.
22. Terravista, Section 1 – Maintenance Bond for Wastewater Collection System located
off Long Lane. - $45,690
Recommendation: Extend in the current amount for a period of one (1) year.
23. The Mill at Bond Springs, Section 1 – Performance Bond for Roads, Drainage and
Erosion Control located off Bethesda Road. - $300,000
Recommendation: Reduce in the amount of $225,000 for a period of one (1) year.
24. Troubadour Golf Club/Farmstead – Performance Bond or Landscaping located off
Patton Road. - $150,738
Recommendation: Extend in current amount for a period of six (6) months to allow
for completion.
25. Troubadour, Section 2 – Maintenance Bond for Roads, Drainage and Erosion Control
located off Patton Road. - $567,000
Recommendation: Reduce bond to $425,000 for a period of one (1) year; or when
Engineering staff has determined the improvements have been completed and the
bond is ready for review by the Planning Commission; whichever comes first.
26. White Horse Farms – Performance Bond for Landscaping located off Murfreesboro
Road. - $69,369
Recommendation: Extend in the current amount for a period of six (6) months to
allow for completion.
Williamson County Planning Commission
Meeting of April 20, 2026
Page 4 of 10
DEFERRAL ITEMS:
ITEM 28
CONCEPT PLAN REVIEW FOR 3036 OLD MURFREESBORO ROAD SUBDIVISION,
CONTAINING 30 LOTS ON 34.15 ACRES LOCATED OFF OLD MURFREESBORO
ROAD IN THE 5TH VOTING DISTRICT (1-2025-213).
At this time, the applicant is requesting deferral to the May 2026 Planning Commission
Meeting in order to allow the applicant more time to address Staff comments. Staff
concurs with this request.
ITEM 29
PRELIMINARY PLAT REVIEW FOR CHESTNUT HILL FARMS LLE SUBDIVISION,
CONTAINING 5 LOTS ON 28.5 ACRES LOCATED OFF WHIPPOORWILL DRIVE
IN THE 1ST VOTING DISTRICT (1-2025-324).
At this time, the applicant is requesting deferral to the May 2026 Planning Commission
Meeting in order to allow the applicant more time to address Staff comments. Staff
concurs with this request.
ITEM 33
PRELIMINARY PLAT REVIEW FOR JOYBELLE ESTATES SUBDIVISION,
CONTAINING 12 LOTS ON 110.1 ACRES LOCATED OFF EUDAILEY COVINGTON
ROAD IN THE 2ND VOTING DISTRICT (1-2026-304).
At this time, the applicant is requesting deferral to the May 2026 Planning Commission
Meeting in order to allow the applicant more time to address Staff comments. Staff
concurs with this request.
ITEM 34
PRELIMINARY PLAT REVIEW FOR 8828 HORTON HIGHWAY, CONTAINING 5
LOTS ON 28.01 ACRES LOCATED OFF HORTON HIGHWAY IN THE 2ND VOTING
DISTRICT (1-2025-334).
At this time, the applicant is requesting deferral to the May 2026 Planning Commission
Meeting in order to allow the applicant more time to address Staff comments. Staff
concurs with this request.
OLD BUSINESS:
ITEM 27
ROADS, DRAINAGE AND EROSION CONTROL BOND REVIEW OF TERRAVISTA
SUBDIVISION, SECTIONS 1 AND 2.
Brent Thoeny , with True Land Consultants, represented the applicant , The Jones
Company. He reported that Section 2 slope repairs are approved, and the geotechnical
letter has been submitted. The bio pond remains too wet despite drainage efforts; the
team is awaiting drier conditions and will meet with the engineer to evaluate solutions. A
bid has been received for the wastewater road, with paving under consideration pending
Williamson County Planning Commission
Meeting of April 20, 2026
Page 5 of 10
county feedback. Service road construction is anticipated within 30 –45 days. Section 1
bids are under review to confirm scope and timeline. Landscaping (approx. eight trees)
is expected within one to two weeks.
Vice-Chairman Crohan asked if there were any questions. Hearing none, he thanked Mr.
Thoeny.
ITEM 28
CONCEPT PLAN REVIEW FOR 3036 OLD MURFREESBORO ROAD SUBDIVISION,
CONTAINING 30 LOTS ON 34.15 ACRES LOCATED OFF OLD MURFREESBORO
ROAD IN THE 5TH VOTING DISTRICT (1-2025-213).
This Item is on the Consent Agenda as a deferral.
ITEM 29
PRELIMINARY PLAT REVIEW FOR CHESTNUT HILL FARMS LLE SUBDIVISION,
CONTAINING 5 LOTS ON28.5 ACRES LOCATED OFF WHIPPOORWILL DRIVE IN
THE 1ST VOTING DISTRICT (1-2025-324).
This Item is on the Consent Agenda as a deferral.
PUBLIC HEARINGS:
ITEM 30
AMENDMENT TO THE SUBDIVISION REGULATIONS REGARDING EXPIRATION
OF PLATS WITHOUT SURETIES (6-2026-600).
Mr. Holmes reviewed the background (see Staff Report) recommending approval of the
text amendment.
Vice-Chairman Crohan noted that no one signed up for the Public Hearing.
Commissioner Lucyshyn made a motion to approve per Staff recommendation.
Commissioner Sanders seconded the motion. The motion was unanimously approved.
ITEM 31
AMENDMENTS TO ARTICLES 11 AND 23 OF THE ZONING ORDINANCE
REGARDING THE USE OF NONTRADITIONAL WASTEWATER TREATMENT AND
DISPOSAL SYSTEMS WITHIN THE URBAN GROWTH BOUNDARIES (UGB’S) (6-
2026-601).
Mr. Holmes reviewed the background (see Staff Report) recommending approval of the
text amendments and that the attached Resolution be forwarded to the County
Commission for adoption.
Vice-Chairman Crohan noted that no one signed up for the Public Hearing.
Commissioner Clifford asked about the practical effects of prohibiting the systems within
the Urban Growth Boundaries now as compared to before.
Williamson County Planning Commission
Meeting of April 20, 2026
Page 6 of 10
Mr. Holmes advised that all of the properties within the Urban Growth Boundary were
zoned either MGA-1 or MGA-5 or MGA-Hamlet. The newly revised Urban Growth
Boundaries now include properties that are zoned Rural Preservation-5 or Rural
Development-5, and the types of wastewater systems are allowed within the RD-5 and
RP-5 districts. Speaking with the cities, the retrofitting of a non-traditional system to a
municipal system is difficult and costly. The cities asked that these not be permitted in
the Urban Growth Boundaries.
Mr. Matteson added that for many years the policy has been to not allow these systems
in the Growth Boundaries except for individual uses, such as churches or schools. That’s
the same policy that we’ve continued to have and have now. The only difference is that
now there are a few areas within the Growth Boundaries that are zoned RD-5 or RP-5,
and we just want to make sure these same policies we’ve had are reflected in these two
zoning districts when they’re inside the UGBs.
Commissioner Clifford asked if the cities annexed into the UGBs, how would they
connect to those systems.
Mr. Matteson added that the systems would present an impediment to the city’s
annexation because they don’t have those kinds of systems. They have public sewer
and retrofitting the systems would be difficult.
Commissioner Clifford asked about how the average homeowner living within the UGB
feels about the proposed change, about the cost, burden, and how it would affect those
property owners?
Mr. Matteson noted that most people who live within the UGB who want to be annexed
into the city and tap into the city sewer, and to develop their property in conjunction
with the City’s policies on growth and development. He noted the recent addition of
properties to the growth boundaries and the need to be consistent across the board.
Commissioner Clifford asked if a property owner doesn’t have an interest in being
annexed, how will they view the proposed amendment, and if the change would limit
their development options.
Mr. Matteson noted that if a property owner does not want to be annexed, they
probably don’t have designs for developing the property. The property owner would be
limited because they’d be looking at septic or requesting sewer from the municipalities,
which is consistent with the way the policy’s been for many years.
Commissioner Clifford asked how does this align with what the Septic Task Force has
been working on and the recommendations that are forthcoming.
Mr. Matteson responded the proposed amendment doesn’t have a direct bearing,
although if properties within the UGB were developed on septic, then it would to be
easier and less costly to do so. He clarified the proposed amendment would not impede
the new septic regulations.
Commissioner McCord asked if someone has a property at the furthest end of the UGB,
is there an appeal process for this to get a variance to allow use of a wastewater
system.
Mr. Holmes noted any request to use a nontraditional wastewater system where it
wasn’t currently allowed would be considered a use variance, which is something the
BZA can’t grant. An amendment to the Zoning Ordinance would be required to allow the
system where it isn’t currently allowed.
Williamson County Planning Commission
Meeting of April 20, 2026
Page 7 of 10
Commissioner McCord asked for clarification of what options were available for the
property and the property owner.
Mr. Holmes indicated the property could be developed with individual onsite septic
systems.
Mr. Matteson added the RD-5 and RP-5 zoning districts are one unit per five acres, and
that nontraditional wastewater systems aren’t very common for low density
development like that. It’s much more common that septic systems are used.
Vice-Chairman Crohan noted his understanding is that if a property is located within the
UGB area and the city decides to annex the property, that the property owner doesn’t
have a choice unless they were to go to the state. If the property is located within the
UGB, the property has been designated for annexation at some point.
Mr. Matteson responded that the property owner would have the ability to say “I don’t
want to be annexed,” and the cities wouldn’t automatically be able to annex them.
Additionally, there’s also a mechanism for people to request to be removed from the
Urban Growth Boundaries, as they are periodically revisited.
Commissioner Lucyshyn added her understanding was that not allowing the systems
inside the UGB was the policy within the UGBs for some time. It’s only recently, when
the UGBs were redrawn, that some properties ended up inside the UGB that are zoned
RD-5 and RP-5. We’re not putting an undue hardship on them or on anyone within the
UGB.
Mr. Matteson confirmed that she was correct.
Vice-Chairman Crohan asked if there were any other questions. Hearing none, he asked
for a motion.
Commissioner Lucyshyn made a motion to approve per Staff recommendation.
Commissioner Lane seconded the motion.
The motion was unanimously approved.
CONCEPT PLANS:
ITEM 32
CONCEPT PLAN REVIEW FOR WILLOWSTONE ESTATES (AKA CLOVERCROFT
ESTATES), CONTAINING 25 LOTS ON 184.62 ACRES LOCATED OFF
CLOVERCROFT ROAD IN THE 4TH VOTING DISTRICT (1-2025-211).
Mr. Holmes reviewed the background (see Staff Report) recommending approval of this
Concept Plan with the following conditions:
The Preliminary Plat must address the following:
1. Submission of roads, drainage and erosion control plans for review and approval
by the County; and
2. Submission of water plans for review and approval by Nolensville/College Grove
Utility District.
The Final Plat must address the following:
Williamson County Planning Commission
Meeting of April 20, 2026
Page 8 of 10
1. Prior to consideration of Final Plat approval, the applicant shall submit HOA
documents for review and approval by the County Attorney’s office. The HOA
documents must be submitted with the Final Plat, and the approved HOA
documents must be recorded concurrently with the recording of the Final Plat;
2. Establishment of a Performance Bond for roads, drainage and erosion control;
3. Establishment of a Performance Bond for water improvements in favor of
Nolensville/College Grove Utility District;
4. Per the recommendation of the County’s Wastewater Consultant, establishment of
a Performance Bond for the Treatment and Disposal System and the Wastewater
Collection System;
5. Submission of landscaping plans and establishment of a Performance Bond for
landscaping;
6. Execution of Performance Agreements for the above referenced sureties;
7. Execution of a Stormwater Maintenance Agreement and submission of an
Operation and Maintenance Plan for stormwater improvements; and
8. Submission of the approved Final Plat in .dwg format on recordable media based
on the Tennessee State Plane Coordinate System prior to signature and recording
of the plat.
Vice-Chairman Crohan asked if the applicant was present.
Joshua Denton, represented the applicant, and advised that he and the Engineer, Mr.
Wilson, would be available to answer questions.
Commissioner Bailey asked if the development was going to be gated.
Mr. Denton replied that it will not be gated because it connects to an existing development
that has public streets.
Commissioner Bailey asked where the additional lots would be located on the future
revision to the Concept Plan.
Mr. Denton noted the location of where some of the lots could potentially be located. He
referenced the Concept Plan presented at the February meeting and noted there wasn’t
sufficient wastewater capacity for all lots. He explained the Concept Plan has tailored the
number of lots to the capacity of the wastewater system that’s available. He noted any
revisions will be subject to the County’s review and approval.
Commissioner Lucyshyn added that if the applicant wants to revise the Concept Plan why
would he want approval for something that is going to change.
Mr. Denton replied that the current Concept Plan meets the requirements, and that his
client is asking for twenty-five (25) lots. He further noted that there could be a request
for additional lots, and if the expansion to the wastewater system was approved , the
applicant would likely request the additional lots. However, he noted that adding
additional lots might not occur, and so the presented Concept Plan was designed for the
wastewater system’s available capacity, and that it meets all of the County’s criteria, and
they are asking for approval.
Williamson County Planning Commission
Meeting of April 20, 2026
Page 9 of 10
Vice-Chairman Crohan asked if there were any other questions. Hearing none, he asked
for a motion.
Commissioner Clifford made a motion to approve per Staff recommendation .
Commissioner Lane seconded the motion. The motion was unanimously approved.
PRELIMINARY PLATS:
ITEM 33
PRELIMINARY PLAT REVIEW FOR JOYBELLE ESTATES SUBDIVISION,
CONTAINING 12 LOTS ON 110.1 ACRES LOCATED OFF EUDAILEY COVINGTON
ROAD IN THE 2ND VOTING DISTRICT (1-2026-304).
This Item is on the Consent Agenda as a deferral.
ITEM 34
PRELIMINARY PLAT REVIEW FOR 8828 HORTON HIGHWAY, CONTAINING 5
LOTS ON 28.01 ACRES LOCATED OFF HORTON HIGHWAY IN THE 2ND VOTING
DISTRICT (1-2025-334).
This Item is on the Consent Agenda as a deferral.
FINAL PLATS:
ITEM 35
FINAL PLAT REVIEW (REVISED) FOR TALIAFERRO SUBDIVISION,
CONTAINING 27 LOTS ON 196.93 ACRES LOCATED OFF TALIAFERRO ROAD IN
THE 5TH VOTING DISTRICT (1-2026-404).
Mr. Waldrop reviewed the background (see Staff Report) recommending approval of the
Final Plat with the following conditions:
1. The approved HOA documents must be recorded concurrently with the recording
of the Final Plat;
2. Establishment of a Performance Bond for roads, drainage and erosion control in
the amount of $1,122,000, this amount is based on work completed;
3. Per the recommendation of the County’s Wastewater Consultant, establishment of
a Performance Bond for the wastewater collection system in the amount of
$100,200;
4. Posting of a Performance Bond in the amount of $317,500 for water improvements
as specified by Nolensville College Grove Utility District;
5. Establishment of a performance bond for landscaping in the amount of $31,410;
6. Execution of Performance agreements for the above referenced sureties;
7. Execution of a Stormwater Maintenance Agreement and submission of an
Operation and Maintenance Plan for stormwater improvements; and
Williamson County Planning Commission
Meeting of April 20, 2026
Page 10 of 10
8. Providing two (2) copies of the approved Final Plat in .dwg format on recordable
media based on the Tennessee State Plane Coordinate System prior to signature
and recording of the Final Plat.
Vice-Chairman Crohan asked if there were any questions for Staff. Hearing none, he
asked for a motion.
Commissioner Sanders made a motion to approve per Staff recommendations.
Commissioner Clifford seconded the motion. The motion was unanimously approved.
Vice-Chairman Crohan made a motion to adjourn. There being no further business, the
meeting was adjourned at approximately 5:53 p.m.
APPROVED BY A MAJORITY VOTE BY THE WILLIAMSON COUNTY REGIONAL
PLANNING COMMISSION ON MAY 14, 2026
____________________________________
Chairman
CONSENT AGENDA
WILLIAMSON COUNTY REGIONAL PLANNING COMMISSION
WILLIAMSON COUNTY ADMINISTRATIVE COMPLEX
MAY 14, 2026
BONDS:
3. Arrington Woods, Section 1 – Performance Bond for Landscaping located off
Nolensville Road. - $39,576
Recommendation: Extend in the current amount for a period of six (6) months in
order to allow for completion.
4. Arrington Woods, Section 1 – Performance Bond for Roads, Drainage and Erosion
Control located off Nolensville Road. - $263,000
Recommendation: Extend in the current amount for a period of one (1) year.
5. Daventry, Section 1 – Maintenance Bond for Roads, Drainage and Erosion Control
located off Tulloss Road. - $200,000
Recommendation: Reduce to the amount of $100,000 for a period of one (1) year; or
when Engineering staff has determined the improvements have been completed and
the bond is ready for review by the Planning Commission, whichever comes first.
6. Daventry, Section 3 - Maintenance Bond for Roads, Drainage and Erosion located off
Tulloss Road. - $185,000
Recommendation: Reduce to the amount of $93,000 for a period of one (1) year; or
when Engineering staff has determined the improvements have been completed and
the bond is ready for review by the Planning Commission, whichever comes first.
7. Enclave at Dove lake, Section 2 – Maintenance Bond for Roads, Drainage and Erosion
Control located off Nolensville Road. - $550,000
Recommendation: Extend in the current amount for a period of one (1) year.
8. Fiddlers Glen/Cox Ladd Treatment Facility – Maintenance Bond for Landscaping
located off Murfreesboro Road. - $3,000
Recommendation: Extend in the current amount for a period of six (6) months in order
to allow for completion.
9. Fiddlers Glen, Section 1 – Performance Bond for Roads, Drainage and Erosion Control
located off Murfreesboro Road. - $2,887,000
Recommendation: Reduce to the amount of $2,165,000 for a period of one (1) year.
10. Hardeman Springs, Section 1 – Maintenance Bond for Roads, Drainage and Erosion
Control located off Murfreesboro Road. - $400,000
Recommendation: Extend in the current amount for a period of one (1) year.
11. Hart’s Landmark – Maintenance Bond for Sewer Improvements located off Hartland
Drive. - $20,000
Recommendation: Harpeth Wastewater Cooperative is requesting this bond be
extended in the current amount for a period of one (1) year. Staff concurs with this
request.
12. High Park Hill Amenity - Performance Bond for Landscaping off Murfreesboro Road. -
$167,079
Recommendation: Extend in the current amount for six (6) months in order to allow
for completion.
13. High Park Hill Amenity – Performance Bond for Wastewater Collection System located
off Murfreesboro Road. - $12,120
Recommendation: Reduce to Maintenance in the amount of $3,636 for a period of
two (2) years.
14. High Park Hill, Section 4 – Performance Bond for Roads, Drainage and Erosion Control
located off Murfreesboro Road. - $850,000
Recommendation: Extend in the current amount for a period of one (1) year.
15. Reeds Vale Amenity Center - Performance Bond for Landscaping located off Lampkins
Bridge Road. - $29,755
Recommendation: Extend in the current amount for a period of six (6) months in order
to allow for completion.
16. Reeds Vale, Section 1 – Maintenance Bond for Roads, Drainage and Erosion Control
located off Lampkins Bridge Road. - $1,000,000
Recommendation: Reduce to the amount of $850,000 for a period of one (1) year.
17. Reeds Vale, Section 2 – Performance Bond for Landscaping located off Lampkins
Bridge Road. - $46,849
Recommendation: Extend in the current amount for a period of six (6) months in
order to allow for completion.
18. St. Barbara’s Coptic Church – Maintenance Bond for Landscaping located off
Clovercroft Road. - $65,000
Recommendation: Release the bond.
19. St. Marlo, Section 3 – Maintenance Bond for Wastewater Collection System located
off Long Lane. - $57,200
Recommendation: Release the bond.
20. Taliaferro Subdivision – Performance Bond for Landscaping located off Taliaferro
Road. - $31,410
Recommendation: Release the bond.
21. Taliaferro Subdivision – Performance Bond for Roads, Drainage and Erosion Control
located off Taliaferro Road. - $1,122,000
Recommendation: Extend in the current amount for a period of one (1) year.
22. Vista Creek – Performance Bond or Landscaping located off Old Hillsboro Road. -
$47,484
Recommendation: Release the bond.
DEFERRAL ITEMS:
ITEM 24
PRELIMINARY PLAT REVIEW FOR LOT 1 OF THE LARRY U. TURNER PROPERTY
LLE SUBDIVISION, CON TAINING 1 LOT ON 20.33 ACRES LOCAT ED OFF CARL
ROAD IN THE 5TH VOTING DISTRICT (1 -2026-301).
At this time, the applicant is requesting deferral to the August 2026 Planning Commission
Meeting in order to allow the applicant more time to address Staff comments. Staff
concurs with this request.
ITEM 30
PRELIMINARY PLAT REVIEW FOR DODD FAMILY REVOCABLE LIVING TRU ST
SUBDIVISION, CONTAINING 1 LOT ON 32.12 ACRES LOCATED OFF
TALIAFERRO ROAD IN THE 5TH VOTING DISTRICT (1-2026-305)
At this time, the applicant is requesting deferral to the June 2026 Planning Commission
Meeting in order to allow the applicant more time to address Staff comments. Staff
concurs with this request.
ITEM 32
FINAL PLAT REVIEW FOR FOSTER SUBDIVISION FAMILY SUBDIVISION,
CONTAINING 1 LOT ON 1.40 ACRES LOCATED O FF TALIAFERRO ROAD IN THE
5TH VOTING DISTRICT (1-2026- 409)
At this time, the applicant is requesti ng deferral to the June 2026 Planning Commission
Meeting in order to allow the applicant more time to address Staff comments. Staff
concurs with this request.
ITEM 35
FINAL PLAT REVIEW FO R HIGH PARK HILL SUB DIVISION, SECTION 5,
CONTAINING 40 LOTS ON 59.86 ACRES LOCATED OFF MURFREESBORO ROAD
IN THE 5TH VOTING DISTRICT (1-2026-407).
At this time, the applicant is requesting deferral to the June 2026 Planning Commission
Meeting in order to allow the applicant more time to address Staff comments. Staff
concurs with this request.
MOTION TO ACCEPT STAFF RECOMMENDATION
1
st _____ 2nd ______ VOTE: ___________
NOTE: All matters listed under the consent agenda are considered to be routine.
There will be no separate discussion of these items unless a Planning
Commission member so requests, in which case it will be removed from the
Consent Agenda so that discussion may be held on that item.
Reviewer: OCW
Date: 05/14/2026
ITEM 3
NAME: ARRINGTON WOODS, SECTION 1
BOND TYPE: PERFORMANCE BOND FOR LANDSCAPING
LOCATION: OFF NOLENSVILLE ROAD
BACKGROUND: The following table shows the previous history of the bond.
MEETING DATE BOND TYPE ACTION TAKEN BOND AMOUNT
January 2025 Performance Implemented $39,576
LAST ACTION: At the January 2025 meeting, this body granted approval of this final
plat with the following conditions: 1) The HOA documents shall address the requirements
of Section 17.11: Gated Subdivisions and Section 17.12: Private Streets of the Zoning
Ordinance. The HOA documents must be approved prior to the recording of the plat and
the approved HOA documents must be recorded concurrently with the recording of the
Final Plat; 2) A permit for the security gate will need to be obtained prior to its installation,
and all requirements for such gates as outlined in Section 17.11 of the Zoning Ordinance
must be met; 3) Establishment of a Performance Bond for roads, drainage and erosion
control in the amount of $ 327,000. This amount is based on work completed ; 4)
Establishment of a performance bond for landscaping in the amount of $39,576; 5)
Posting of a Performanc e Bond in the amount of $462,500 for water improvements as
specified by Nolensville College Grove Utility District ; 6) Execution of Performance
agreements for the above referenced sureties; 7) Execution of a Stormwater Maintenance
Agreement and submission of an Operation and Maintenance Plan for stormwater
improvements; and 8) Providing two (2) copies of the approved Final Plat in .dwg format
on recordable media based on the Tennessee State Plane Coordinate System prior to
signature and recording of the Final Plat.
RECOMMENDATION: Staff visited the site and noted that the landscaping had not been
installed. Staff recommends extending the bond for a period of six (6) months in order
to allow for completion.
CURRENT RECOMMENDED
$39,576 $39,576
Performance Performance
Reviewer: MS
Date: 05/14/2026
ITEM 4
NAME: ARRINGTON WOODS, SECTION 1
BOND TYPE: PERFORMANCE BOND FOR ROADS, DRAINAGE AND
EROSION CONTROL
LOCATION: OFF NOLENSVILLE ROAD
BACKGROUND: The following table shows the previous history of the bond.
MEETING DATE BOND TYPE ACTION TAKEN BOND AMOUNT
January 2025 Performance Implemented $263,000
LAST ACTION: At the January 2025 meeting, this body granted approval of this final
plat with the following conditions: 1) The HOA documents shall address the requirements
of Section 17.11: Gated Subdivisions and Section 17.12: Private Streets of the Zoning
Ordinance. The HOA documents must be approved prior to the recording of the plat and
the approved HOA documents must be recorded concurrently with the recording of the
Final Plat; 2) A permit for the security gate will need to be obtained prior to its installation,
and all requirements for such gates as outlined in Section 17.11 of the Zoning Ordinance
must be met; 3) Establishment of a Performance Bond for roads, drainage and erosion
control in the amount of $ 327,000. This amount is based on work completed ; 4)
Establishment of a performance bond for landscaping in the amount of $39,576; 5)
Posting of a Performanc e Bond in the amount of $462,500 for water improvements as
specified by Nolensville College Grove Utility District ; 6) Execution of Performance
agreements for the above referenced sureties; 7) Execution of a Stormwater Maintenance
Agreement and submission of an Operation and Maintenance Plan for stormwater
improvements; and 8) Providing two (2) copies of the approved Final Plat in .dwg format
on recordable media based on the Tennessee State Plane Coordinate System prior to
signature and recording of the Final Plat.
RECOMMENDATION: Staff visited the site and noted that some improvements have
been completed. Staff recommends that the Performance Bond be extended in the
current amount for a period of one (1) year.
CURRENT RECOMMENDED
$263,000 $263,000
Performance Performance
Reviewer: MS
Date: 05/14/2026
ITEM 5
NAME: DAVENTRY, SECTION 1
BOND TYPE: MAINTENANCE BOND FOR ROADS, DRAINAGE AND
EROSION CONTROL
LOCATION: TULLOSS RD
BACKGROUND: The following table shows the previous history of the bond.
MEETING DATE BOND TYPE ACTION TAKEN BOND AMOUNT
July 2019 Performance RDE Implemented $200,000
July 2020 Performance RDE Extend $200,000
July 2021 Performance RDE Extend $200,000
July 2022 Performance RDE Extend $200,000
November 2023 Performance RDE Convert to Maint
& Extend
$200,000
May 2024 Maintenance RDE Extend $200,000
May 2025 Maintenance RDE Extend $200,000
LAST ACTION: At the May 2025 meeting, this body granted approval to extend this
bond in the current amount for a period of one (1) year.
RECOMMENDATION: Staff visited the site and noted that most of the improvements
are complete. The applicant has requested a release of the bond, however, there are
items that still need to be completed prior to bond release. St aff recommends that the
Maintenance Bond be reduced to the amount of $100,000 for a period of one (1) year;
or when Engineering staff has determined the improvements have been completed and
the bond is ready for review by the Planning Commission, whichever comes first.
CURRENT RECOMMENDED
$200,000 $100,000
Maintenance Maintenance
Reviewer: MS
Date: 05/14/2026
ITEM 6
NAME: DAVENTRY, SECTION 3
BOND TYPE: MAINTENANCE BOND FOR ROADS, DRAINAGE AND
EROSION CONTROL
LOCATION: OFF TULLOSS ROAD
BACKGROUND: The following table shows the previous history of the bond.
MEETING DATE BOND TYPE ACTION TAKEN BOND AMOUNT
June 2021 Performance RDE Implemented $370,000
May 2022 Performance RDE Extend $370,000
March 2023 Performance RDE Convert to Maint
& Extend
$370,000
May 2024 Maintenance RDE Extend $370,000
May 2025 Maintenance RDE Extend & Reduce $185,000
LAST ACTION: At the May 2025 meeting, this body granted approval to extend and
reduce the bond for a period one (1) year.
RECOMMENDATION: Staff visited the site and noted that most of the improvements
are complete. The applicant has requested a release of the bond, however, there are
items that still need to be completed prior to bond release. St aff recommends that the
Maintenance Bond be reduced to the amount of $93,000 for a period of one (1) year; or
when Engineering staff has determined the improvements ha ve been completed and the
bond is ready for review by the Planning Commission, whichever comes first.
CURRENT RECOMMENDED
$185,000 $93,000
Maintenance Maintenance
Reviewer: MS
Date: 05/14/2026
ITEM 7
NAME: ENCLAVE AT DOVE LAKE, SECTION 2
BOND TYPE: MAINTENANCE BOND FOR ROADS, DRAINAGE AND
EROSION CONTROL
LOCATION: OFF NOLENSVILLE ROAD
BACKGROUND: The following table shows the previous history of the bond.
MEETING DATE BOND TYPE ACTION TAKEN BOND AMOUNT
April 2021 Performance RDE Implemented $1,100,000
May 2022 Performance RDE Reduce to Maint &
Extend
$550,000
May 2023 Maintenance RDE Extend $550,000
May 2024 Maintenance RDE Extend $550,000
May 2025 Maintenance RDE Extend $550,000
LAST ACTION: At the May 2025 meeting, this body granted approval to extend this
bond in the current amount for a period of one (1) year.
RECOMMENDATION: Staff visited the site and noted that some improvements have
been completed. Staff recommends that t he Maintenance bond be extended in the
current amount for a period of one (1) year.
CURRENT RECOMMENDED
$550,000 $550,000
Maintenance Maintenance
Reviewer: OCW
Date: 05/14/2026
ITEM 8
NAME: FIDDLERS GLEN/COX LADD TREATMENT FACILITY
BOND TYPE: MAINTENANCE BOND FOR LANDSCAPING
LOCATION: OFF MURFREESBORO ROAD
BACKGROUND: The following table shows the previous history of the bond.
MEETING
DATE
BOND TYPE ACTION TAKEN BOND
AMOUNT
May 2020 Performance
Landscaping
Implemented $27,400
January 2024 Performance
Landscaping
Extend $27,400
July 2024 Performance
Landscaping
Reduce to
Maintenance &
Extend
$3,000
July 2025 Maintenance
Landscaping
Extend $3,000
December 2025 Maintenance
Landscaping
Extend $3,000
LAST ACTION: At the December 2025 meeting, this body granted approval to extend
this maintenance bond in the amount for a period of six (6) months.
RECOMMENDATION: Staff visited the site and noted that the landscaping had not
been installed. Staff recommends extending the bond for a period of six (6) months in
order to allow for completion.
CURRENT RECOMMENDED
$3,000 $3,000
Maintenance Maintenance
Reviewer: MS
Date: 05/14/2026
ITEM 9
NAME: FIDDLERS GLEN, SECTION 1
BOND TYPE: PERFORMANCE BOND FOR ROADS, DRAINAGE AND
EROSION CONTROL
LOCATION: OFF MURFREESBORO ROAD
BACKGROUND: The following table shows the previous history of the bond.
MEETING DATE BOND TYPE ACTION TAKEN BOND AMOUNT
March 2023 Performance RDE Implemented $2,887,000
February 2024 Performance RDE Extend $2,887,000
February 2025 Performance RDE Extend $2,887,000
LAST ACTION: At the February 2025 meeting, this body granted approval to extend
this bond in the current amount for a period of one (1) year.
RECOMMENDATION: Staff visited the site and noted that some improvements have
been completed. Staff recommends that the Performance Bond be reduced to the
amount of $2,165,000 for a period of one (1) year.
CURRENT RECOMMENDED
$2,887,000 $2,165,000
Performance Performance
Reviewer: MS
Date: 05/14/2026
ITEM 10
NAME: HARDEMAN SPRINGS, SECTION 1
BOND TYPE: MAINTENANCE BOND FOR ROADS, DRAINAGE AND
EROSION CONTROL
LOCATION: OFF MURFREESBORO ROAD
BACKGROUND: The following table shows the previous history of the bond.
MEETING DATE BOND TYPE ACTION TAKEN BOND AMOUNT
May 2019 Performance RDE Implemented $550,000
May 2020 Performance RDE Extend $550,000
May 2021 Performance RDE Extend $550,000
May 2022 Performance RDE Reduce to
Maintenance &
Extend
$500,000
May 2023 Maintenance RDE Extend $500,000
May 2024 Maintenance RDE Extend $500,000
May 2025 Maintenance RDE Extend & Reduce $400,000
LAST ACTION: At the May 2025 meeting, this body granted approval to reduce this
Maintenance Bond and extend for a period of one (1) year.
RECOMMENDATION: Staff visited the site and noted that some improvements have
been completed. Staff recommends that the Maintenance Bond be extended in the
current amount for a period of one (1) y ear.
CURRENT RECOMMENDED
$400,000 $400,000
Maintenance Maintenance
REVIEWER: LE
DATE: 05/14/2026
ITEM 11
NAME: HART’S LANDMARK
BOND TYPE: MAINTENANCE BOND FOR SEWER IMPROVEMENTS
(Harpeth Wastewater Cooperative)
LOCATION: Hartland Drive
BACKGROUND: The following table shows the previous history of the bond.
MEETING DATE BOND TYPE ACTION TAKEN BOND AMOUNT
May 2014 Performance Sewer Implemented $85,970
May 2015 Performance Sewer Extend $85,970
May 2016 Performance Sewer Extend $85,970
May 2017 Performance Sewer Extend $85,970
May 2018 Performance Sewer Extend $85,970
May 2019 Performance Sewer Extend $85,970
November 2019 Performance Sewer Reduce to
Maintenance &
Extend
$40,000
November 2020 Maintenance Sewer Extend $40,000
May 2021 Maintenance Sewer Reduce & Extend $20,000
May 2022 Maintenance Sewer Extend $20,000
May 2023 Maintenance Sewer Extend $20,000
May 2024 Maintenance Sewer Extend $20,000
May 2025 Maintenance Sewer Extend $20,000
LAST ACTION: At the May 2025 meeting, this body granted approval to extend this
bond in the current amount for a period of one (1) year.
RECOMMENDATION: Harpeth Wastewater Cooperative is requesting this bond be
extended in the current amount for a period of one (1) year. Staff concurs with this
request.
CURRENT RECOMMENDED
$20,000 $20,000
Maintenance Maintenance
Reviewer: OCW
Date: 05/14/2026
ITEM 12
NAME: HIGH PARK HILL AMENITY
BOND TYPE: PERFORMANCE BOND FOR LANDSCAPING
LOCATION: OFF MURFREESBORO ROAD
BACKGROUND: The following table shows the previous history of the bond.
MEETING DATE BOND TYPE ACTION TAKEN BOND AMOUNT
May 2025 Performance Implemented $167,079
LAST ACTION: At the May 2025 meeting, this body granted approval of this Site Plan
with the following conditions: 1.) Prior to the recording of the Final Plat of the Section in
which the Amenity Center is located, the HOA documents shall be revised to be consistent
with the requirements and limitations of the Private Recreational Center Use Type as
described by the Zoning Ordinance; 2.) Per the recommendation of the County’s
Wastewater Consultant, the posting of a Performance Bond for the Collection System in
the amount of $12,120; 3.) Posting of a Performance Bond for landscaping improvements
in the amount of $167,079; and 4.) Execution of a Performance Agreement for the above
referenced surety.
RECOMMENDATION: Staff visited the site and noted that most of the landscaping had
been installed, but some trees along the entrance had not been installed. Staff
recommends extending the bond for a period of six (6) months in order to allow for
completion.
CURRENT RECOMMENDED
$167,079 $167,079
Performance Performance
Reviewer: AVH
Date: 05/14/2026
ITEM 13
NAME: HIGH PARK HILL AMENITY
BOND TYPE: PERFORMANCE BOND FOR WASTEWATER COLLECTION
SYSTEM
LOCATION: OFF MURFREESBORO ROAD
BACKGROUND: The following table shows the previous history of the bond.
MEETING DATE BOND TYPE ACTION TAKEN BOND AMOUNT
May 2025 Performance Implemented $12,120
LAST ACTION: At the May 2025 meeting, this body granted approval of this Site Plan
with the following conditions: 1.) Prior to the recording of the Final Plat of the Section in
which the Amenity Center is located, the HOA documents shall be revised to be consistent
with the requirements and limitations of the Private Recreational Center Use Type as
described by the Zoning Ordinance; 2.) Per the recommendation of the County’s
Wastewater Consultant, the posting of a Performance Bond for the Collection System in
the amount of $12,120; 3.) Posting of a Performance Bond for landscaping improvements
in the amount of $167,079; and 4.) Execution of a Performance Agreement for the above-
referenced surety.
RECOMMENDATION: Build-out for this development has been achieved, and we are
in receipt of the required certification letters. Accordingly, it is recomme nded that this
bond be reduced to maintenance in the amount of $3,636 for a period of two (2) years.
CURRENT RECOMMENDED
$12,120 $3,636
Performance Maintenance
Reviewer: MS
Date: 05/14/2026
ITEM 14
NAME: HIGH PARK HILL, SECTION 4
BOND TYPE: PERFORMANCE BOND FOR ROADS, DRAINAGE AND
EROSION CONTROL
LOCATION: OFF MURFREESBORO RD
BACKGROUND: The following table shows the previous history of the bond.
MEETING
DATE
BOND TYPE ACTION TAKEN BOND
AMOUNT
February 2025 Performance RDE Implemented $1,000,000
August 2025 Performance RDE Extend & Reduce $850,000
LAST ACTION: At the August 2025 meeting, this body granted approval Extend and
Reduce in the current amount for a period of one (1) yea r.
RECOMMENDATION: Staff visited the site and noted that some improvements have
been completed. Staff recommends that the Performance Bond be extended in the
current amount for a period of one (1) year.
CURRENT RECOMMENDED
$850,000 $850,000
Performance Performance
Reviewer: OCW
Date: 05/14/2026
ITEM 15
NAME: REEDS VALE AMENITY CENTER
BOND TYPE: PERFORMANCE BOND FOR LANDSCAPING
LOCATION: OFF LAMPKINS BRIDGE ROAD
BACKGROUND: The following table shows the previous history of the bond.
MEETING DATE BOND TYPE ACTION TAKEN BOND AMOUNT
November 2023 Performance
Landscaping
Implemented $29,755
December 2024 Performance
Landscaping
Extend $29,755
June 2025 Performance
Landscaping
Extend $29,755
December 2025 Performance
Landscaping
Extend $29,755
LAST ACTION: At the December 2025 meeting, this body granted approval to extend
this bond in the current amount for a period of six (6) months.
RECOMMENDATION: Staff visited the site and noted that most of the landscaping
had been installed, but some trees had not been installed along the western property
line. Staff recommends extending the bond for a period of six (6) months in order to
allow for completion.
CURRENT RECOMMENDED
$29,755 $29,755
Performance Performance
Reviewer: MS
Date: 05/14/2026
ITEM 16
NAME: REEDS VALE, SECTION 1
BOND TYPE: MAINTENANCE BOND FOR ROADS, DRAINAGE AND
EROSION CONTROL
LOCATION: OFF LAMPKINS BRIDGE ROAD
BACKGROUND: The following table shows the previous history of the bond.
MEETING DATE BOND TYPE ACTION TAKEN BOND AMOUNT
May 2023 Performance RDE Implemented $2,781,000
May 2024 Performance RDE Reduce to
Maintenance &
Extend
$1,391,000
May 2025 Maintenance RDE Reduce & Extend $1,000,000
LAST ACTION: At the May 2025 meeting, this body granted approval to reduce this
bond in the current amount for a period of one (1) year.
RECOMMENDATION
: Staff visited the site and noted that some improve ments have
been completed. Staff recommends that the Maintenan ce Bond be reduced to the
amount of $850,000 for a period of one (1) year.
CURRENT RECOMMENDED
$1,000,000 $850,000
Maintenance Maintenance
Reviewer: OCW
Date: 05/14/2026
ITEM 17
NAME: REEDS VALE, SECTION 2
BOND TYPE: PERFORMANCE BOND FOR LANDSCAPING
LOCATION: OFF LAMPKINS BRIDGE ROAD
BACKGROUND: The following table shows the previous history of the bond.
MEETING DATE BOND TYPE ACTION TAKEN BOND AMOUNT
December 2023 Performance
Landscaping
Implemented $46,849
December 2024 Performance
Landscaping
Extend $46,849
June 2025 Performance
Landscaping
Extend $46,849
December 2025 Performance
Landscaping
Extend $46,849
LAST ACTION: At the December 2025 meeting, this body granted approval to extend
this bond in the current amount for a period of six (6) months.
RECOMMENDATION: Staff visited the site and noted that most of the landscaping
had been installed, but some trees had not been installed near the Ladd Road entrance.
Staff recommends extending the bond for a period of six (6) months in order to allow
for completion.
CURRENT RECOMMENDED
$46,849 $46,849
Performance Performance
Reviewer: OCW
Date: 05/14/2026
ITEM 18
NAME: ST. BARBARA’S COPTIC CHURCH
BOND TYPE: MAINTENANCE BOND FOR LANDSCAPING
LOCATION: OFF CLOVERCROFT ROAD
BACKGROUND: The following table shows the previous history of the bond.
MEETING DATE BOND TYPE ACTION TAKEN BOND AMOUNT
July 2023 Performance
Landscaping
Implemented $213,917
December 2024 Performance
Landscaping
Defer $213,917
January 2025 Performance
Landscaping
Reduce to
Maintenance &
Extend
$65,000
December 2025 Performance
Landscaping
Extend $65,000
LAST ACTION: At the December 2025 meeting, Staff recommends this bond be
Extended in the current amount for a period of six (6) months.
RECOMMENDATION: Staff visited the site and noted that the required landscaping
had been installed per the plan. Staff recommends releasing the bond.
CURRENT RECOMMENDED
$65,000
Maintenance Release
Reviewer: AVH
Date: 05/14/2026
ITEM 19
NAME: ST. MARLO, SECTION 3
BOND TYPE: MAINTENANCE BOND FOR WASTEWATER COLLECTION
SYSTEM
LOCATION: OFF LONG LANE
BACKGROUND: The following table shows the previous history of the bond.
MEETING
DATE
BOND TYPE ACTION TAKEN BOND
AMOUNT
January 2023 Performance WW
Collection System Implemented $57,200
January 2024 Performance WW
Collection System Implemented $57,200
May 2024 Performance WW
Collection System
Extend & Reduce
to Maintenance $17,160
LAST ACTION: At the May 2024 meeting, this body granted approval to extend this
bond to Maintenance and Reduce in the current amount for a period of one (2) year.
RECOMMENDATION: This bond has satisfied the requisite two (2) year maintenance
period. Therefore, Staff recommends releasing the bond.
CURRENT RECOMMENDED
$57,200
Maintenance Release
Reviewer: OCW
Date: 05/14/2026
ITEM 20
NAME: TALIAFERRO SUBDIVISION
BOND TYPE: PERFORMANCE BOND FOR LANDSCAPING
LOCATION: OFF TALIFERRO ROAD
BACKGROUND: The following table shows the previous history of the bond.
MEETING DATE BOND TYPE ACTION TAKEN BOND AMOUNT
June 2025 Performance Implemented $31,410
LAST ACTION: At the June 2025 meeting, this body granted approval of this Final Plat
with the following conditions: 1.) The approved HOA documents must be recorded
concurrently with the recording of the Final Plat; 2.) Establishment of a Performance Bond
for roads, drainage and erosion control in the amount of $1,122,000, this amount is based
on work completed; 3.) Per the recommendation of the County’s Wastewater Consultant,
establishment of a Performance Bond for the wastewater collection system in the amount
of $100,200; 4.) Posting of a Performanc e Bond in the amount of $317,500 for water
improvements as specified by Nolensville/Grove Utility District; 5.) Establishment of a
performance bond for landscaping in the amount of $31,410; 6.) Execution of
Performance agreements for the above referenced sureties; 7.) Execution of a
Stormwater Maintenance Agreement and submission of an Operation and Maintenance
Plan for stormwater improvements; and 8.) Providing two (2) copies of the approved
Final Plat in .dwg format on recordable media based on the Tennessee State Plane
Coordinate System prior to signature and recording of the Final Plat.
RECOMMENDATION: Staff visited the site and noted that the required landscaping had
been installed per the plan. Staff recommends releasing the bond.
CURRENT RECOMMENDED
$31,410
Performance Release
Reviewer: MS
Date: 05/14/2026
ITEM 21
NAME: TALIAFERRO SUBDIVISION
BOND TYPE: PERFORMANCE BOND FOR ROADS, DRAINAGE AND
EROSION CONTROL
LOCATION: OFF TALIFERRO ROAD
BACKGROUND: The following table shows the previous history of the bond.
MEETING DATE BOND TYPE ACTION TAKEN BOND AMOUNT
June 2025 Performance Implemented $1,122,000
LAST ACTION: At the June 2025 meeting, this body granted approval of this Final Plat
with the following conditions: 1.) The approved HOA documents must be recorded
concurrently with the recording of the Final Plat; 2.) Establishment of a Performance Bond
for roads, drainage and erosion control in the amount of $1,122,000, this amount is based
on work completed; 3.) Per the recommendation of the County’s Wastewater Consultant,
establishment of a Performance Bond for the wastewater collection system in the amount
of $100,200; 4.) Posting of a Performanc e Bond in the amount of $317,500 for water
improvements as specified by Nolensville/Grove Utility District; 5.) Establishment of a
performance bond for la ndscaping in the amount of $31,410; 6.) Execution of
Performance agreements for the above referenced sureties; 7.) Execution of a
Stormwater Maintenance Agreement and submission of an Operation and Maintenance
Plan for stormwater improvements; and 8.) Providing two (2) copies of the approved
Final Plat in .dwg format on recordable media based on the Tennessee State Plane
Coordinate System prior to signature and recording of the Final Plat.
RECOMMENDATION: Staff visited the site and noted that some improvem ents have
been completed. Staff recommends that the Performance Bond be extended in the
current amount for a period of one (1) year.
CURRENT RECOMMENDED
$1,122,000 $1,122,000
Performance Performance
Reviewer: OCW
Date: 05/14/2026
ITEM 22
NAME: VISTA CREEK
BOND TYPE: PERFORMANCE BOND FOR LANDSCAPING
LOCATION: OFF OLD HILLSBORO ROAD
BACKGROUND: The following table shows the previous history of the bond.
MEETING
DATE
BOND TYPE ACTION TAKEN BOND
AMOUNT
November 2024 Performance
Landscaping
Implemented $47,484
December 2025 Performance
Landscaping
Extend $47,484
LAST ACTION: At the December 2025 meeting, Staff recommended this bond be
extended in the current amount for a period of six (6) months to allow completion.
RECOMMENDATION: Staff visited the site and noted that the required landscaping
had been installed per the plan. Staff recommends releasing the bond.
CURRENT RECOMMENDED
$47,484
Implement Release
Item 23—Page 1 of 1
Date: 5-14-2026
ITEM 23
TERRAVISTA ROADS, DRAINAGE, AND EROSION CONTROL BOND UPDATE
Item 24—Page 1 of 1
Reviewer: LS
Date: 5/14/2026
ITEM 24
PRELIMINARY PLAT REVIEW FOR LOT 1 OF THE LARRY U. TURNER PROPERTY
LLE SUBDIVISION, CONTAINING 1 LOT ON 20.33 ACRES LOCATED OFF CARL
ROAD IN THE 5TH VOTING DISTRICT (1-2026-301).
Area 20.33 acres
Zoning Rural Development-5
Lots 1
Water Individual Well
Sewer Individual On-Site Septic Systems
Development Option Large Lot Easement
Chapter 1101 Status Rural
Map and Parcel 159---01104
File Number (1-2026-301)
At this time, the applicant is requesting deferral to the August 2026 Planning
Commission Meeting in order to allow the applicant more time to address Staff
comments. Staff concurs with this request.
Item 25—Page 1 of 3
Reviewer: JYJ
Date: 5/14/2026
ITEM 25
CONCEPT PLAN REVIEW FOR WILSON BRANCH FARMS (AKA 3036 OLD
MURFREESBORO ROAD ) SUBDIVISION, CONTAINING 28 LOTS ON 34.15
ACRES LOCATED OFF OLD MURFREESBORO ROAD IN THE 5 TH VOTING
DISTRICT (1-2025-213).
Attachment 25-1 Concept Plan
25-2 Aerial Photograph
Area 34.15 acres (0.84 DU/A)
Lots 28
Zoning Triune Character Area–2 (TCA-2)
Water Nolensville/College Grove Utility District
Sewer Triune Sewer Facility
Development Options Major Traditional Subdivision
Chapter 1101 Status PGA
Map and Parcels 113—038.00; 040.00 and 040.01
File Number (1-2025-213)
The applicant is requestin g Concept Plan approval for a 28 -lot Major Traditional
Subdivision in the Triune Character Area–2 (TCA-2) district. Concept Plan approval is the
first stage in the development process.
The proposed development consists of twenty -eight (28) lots, which range in size from
21,780 to 32,644 square feet, with an average lot size of 23,907 square feet. The overall
density is 0.84 dwelling units per acre. Surrounding properties range in size from one
(1) acre to ninety-one (91) acres and are used for residential or agricultural purposes.
The subject propert ies total approximately 34 acres in size and are located off Old
Murfreesboro Road approximately a quarter mile east of Nolensville Road . The site
contains a number of natural resources, including moderate and very steep slopes, a
Waterway Natural Area (WNA), wetlands and some woodlands. Approximately forty-five
percent (45%) of the site will be preserved in Open Space, and ninety-one percent (91%)
of the existing tree canopy will be retained. Natural Resource Protections standards have
been met.
The required Open Space strip around the perimeter of the property has been provided.
Water service will be provided by the Nolensville/College Grove Utility District , and
wastewater will be handled via the Triune Sewer Facility. Staff has confirmed the property
is in the service ar ea and the system has adequate capacity to serve the proposed
Item 25—Page 2 of 3
Reviewer: JYJ
Date: 5/14/2026
subdivision, and all bonds associated with said system will be established during the Final
Plat stage.
Access is provided by a single entrance off Old Murfreesboro Road. The internal roadway
network will be publicly maintained. N o off-site roadway improvements are required in
conjunction with this development.
Within the TCA-2 zoning district where the Triune Special Area Plan shows a potential
greenway on a development property, the developer is required to construct a
greenway trail and provide a Public Access Easement. The Triune Special Area Plan
shows a greenway transecting the property and the applican t has provided a fifteen
(15) foot greenway easement and a twelve (12) foot paved trail along Wilson Branch.
Additionally, the applicant has provided a twenty-five (25) foot greenway easement
along the northern property line to accommodate a potential future trail . The greenway
located along the Wilson Branch must be constructed prior to submittal of the Final Plat
for the section in which it is located. This has been added as a condition of approval.
It should be noted that once detailed construction and engineering plans are prepared in
conjunction with the submittal of a Preli minary Plat, changes to the layout, including the
potential for a reduction of lots and relocation of drainage infrastructure, may be
necessary. A Landscaping Plan will also be required.
The Concept Plan is in order, and Staff recommends approval with th e following
conditions:
The Preliminary Plat must address the following:
1. Submission of roads, drainage and erosion control plans for review and approval
by the County;
2. Submission of road names for review and approval by the Williamson County
Emergency Management Agency (EMA); and
3. Submission of water plans for review and approval by Nolensv ille/College Grove
Utility District.
The Final Plat must address the following:
1. Prior to consideration of Final Plat approval, the applicant shall submit HOA
documents for review and approval by the County Attorney’s office. The HOA
documents must be submitted with the Final Plat, and the approved HOA
documents must be recorded concurrently with the recording of the Final Plat;
Item 25—Page 3 of 3
Reviewer: JYJ
Date: 5/14/2026
2. Establishment of a Performance Bond for roads, drainage and erosion control;
3. Prior to submittal of the first Final Plat, the required Zoning Certificate for the
wastewater treatment and disposal system shall be submitted, and all conditions
associated with the wastewater site plan appr oval must be satisfied;
4. Establishment of a P erformance Bond for water improvements in favor of
Nolensville/College Grove Utility District;
5. Per the recommendation of the County’s Wastewater Consultant, establishment of
a Performance Bond for the Treatment and Disposal System and the Wastewater
Collection System;
6. Prior to the issuance of building per mits within the associated Section of the
development in which the greenway located along Wilson Branch is within, the
paved greenway trail shall be constructed;
7. Submission of landscaping plans and establishment of a Performance Bond for
landscaping;
8. Dedication of right -of-way of twenty-five (25) feet off the centerline of Old
Murfreesboro Road;
9. Execution of Performance Agreements for the above referenced sureties;
10. Execution of a Stormwater Maintenance Agreement and submission of an
Operation and Maintenance Plan for stormwater improvements; and
11. Submission of the approved Final Plat in .dwg format on recordable media based
on the Tennessee State Plane Coordinate System prior to signature and recording
of the plat.
C0.0
COVER SHEET
WILSON BRANCH FARMS SUBDIVISION
OLD MURFREESBORO ROAD, WILLIAMSON COUNTY, TN
LOCATION MAP
SCALE: 1" = 2,000'
PROJECT
SITE
CONCEPT PLAN
N
FLOOD NOTE:
THERE IS NO PORTION OF THE SUBJECT
PROPERTIES THAT LIES WITHIN THE 100 YEAR
FLOODPLAIN BASED ON FEMA PANEL
47187C0385G DATED 12/20/2024.
GENERAL
INFORMATION
DEVELOPER
Contact: Brandon Jenkins
Email: brandon@grovepark.com
CIVIL ENGINEER
Crunk Engineering LLC
7112 Crossroads Boulevard, Suite 201
Brentwood, TN 37027
Contact: Will Crunk, PE
Phone: 615.873.1795
Email: will@crunkeng.com
SURVEYOR
Contact: Roger Harrah
Email: rharrah@twm-inc.com
Phone: 615-814-7414
UTILITIES
WATER: NOLENSVILLE/COLLEGE GROVE UTILITY DISTRICT
615-776-2511
2002 JOHNSON INDUSTRIAL BLVD.
NOLENSVILLE, TN 37135
SANITARY SEWER: SUPERIOR WASTEWATER SYSTEMS, LLC
615-834-1222
9539 MULLENS ROAD
ARRINGTON, TN 37014
ELECTRIC: MIDDLE TENNESSEE ELECTRIC
2156 EDWARD CURD LANE
FRANKLIN, TN 37067
GAS: ATMOS ENERGY
810 CRESCENT CENTRE DRIVE, SUITE 600
FRANKLIN, TN 37067
NATURAL GAS NOTE:
DEVELOPER TO NOTIFY THE OPERATOR OF THE
NATURAL GAS TRANSMISSION PIPELINE AS
REQUIRED BY TCA 13-3-414.
05/05/202625051
REVISIONS
No. DATE WILSON BRANCH FARMS SUBDIVISION
CONCEPT PLAN
OLD MURFREESBORO ROAD,
WILLIAMSON COUNTY, TENNESSEE
7112 CROSSROADS BOULEVARD
SUITE 201
BRENTWOOD, TN 37027
(615) 873-1795
WWW.CRUNKENG.COM
CRUNK ENGINEERING LLC
Drawing Path: P:\2025\25051 - 3036 Old Murfreesboro Rd\Dwg\Construction\C0.0-COV.dwg
WI LLIAM
W
. CRUNK
No. 115894
STATE OF
TENNESSEE
REGISTERED
ENGINEER
COMM
ERCE
AGRICULTURE
Sheet List Table
Sheet NumberSheet Title
C0.0COVER SHEET
C1.0EXISTING CONDITIONS
C2.0OVERALL SITE LAYOUT PLAN
C2.1DETAILED SITE LAYOUT PLAN
C2.2DETAILED SITE LAYOUT PLAN
C2.3LOT TABLE & TYPICAL LOT LAYOUT
C2.4OPEN SPACE PLAN
SUBJECT PROPERTY OWNERS
BETTY P. HOPKINS
MAP 113, PARCEL 40.00
BK. 3146, PG. 491
WILLIAM TROY HOPKINS
MAP 113, PARCEL 38.00
BK. 8980, PG 549
WILLIAM TROY HOPKINS
MAP 113, PARCEL 40.01
BK. 8980, PG. 544
ATTACHMENT 25-1A
N68° 06' 29"W
124.50'
N58° 24' 35"W
147.15'
S34°25'43"W 82.00'
N39°35'29"W 586.28'
N30° 01' 47"W
199.88'
N29° 53' 55"W
114.95'
N36° 08' 47"W
108.04' N34° 43' 47"E
200.54'
N28° 09' 52"E
107.96'
N31°29'06"W 109.59'
N43° 58' 37"E
130.19'
S89° 31' 02"E123.26'
S20°01'45"E 60.90'
S77° 00' 41"E154.94'
S77° 57' 21"E154.30'
N83°07'06"E 12.41'
N82°01'33"E 269.22'
N87°23'09"E 46.24'
S70°02'43"E 308.82'
S58° 06' 02"E157.54'S8°33'10"W 1319.63'
N36°27'08"W 195.96'
25' INGRESS, EGRESS & UTILITY EASEMENT
[R] S61°35'00"E 143.20'
[R] N82°45'00"W 327.00'[R] N17°15'00"W 74.00'
[R] N84°30'00"W 100.00'
[R] S30°30'00"W 104.00'
[R] S38°30'00"E 107.50'
S23°00'00"W 137.00'
[R] S30°15'00"W 200.50'
[R] S43°10'00"E 115.20'
[R] S34°00'00"E 314.40'
[R] S40°10'00"E 186.40'
[R] S45°00'00"E 597.00'
[R] N31°00'00"E 82.00'
[R] S75°10'00"E 124.50'
[R] N02°30'00"E 1307.00'
[R] N76°30'00"W 301.50'
[R] S85°30'00"W 57.00'
[R] S75°45'00"W 286.00'
[R] N62°15'00"W 158.00'
[TIE] N61° 15' 26"W
80.77'
DAVID & KRISTIE HARTMAN
TAX MAP 113 | PARCEL 39.01
D.B. 7210 - PG. 975
ROBERT & ANNE KIRK
TAX MAP 113 | PARCEL 37.00
D.B. 8994 - PG. 519
JACK S. SCHNEIDER
TAX MAP 113 | PARCEL 43.01
D.B. 9128 - PG. 808
JAMIE WILEE ET UX
TAX MAP 113 | PARCEL 41.00
D.B. 7045 - PG. 37
OLD MURFREESBORO ROAD
SEWER ESMTDB4967 PG746
50-FT WATERWAY
NATURAL AREA (WNA)
WET WEATHER CONVEYANCE
(WWC1)
WET WEATHER CONVEYANCE
(WWC2)
STREAM 1
STREAM 1
STREAM 1
STREAM 1
50-FT WATERWAY
NATURAL AREA (WNA)
STREAM 2
50-FT WATERWAY
NATURAL AREA (WNA)
WETLAND AREA
(WET_1)
UPLAND AREA
(UP_1)
SPRING
N22° 31' 13"E
243.52
N57° 32' 50"W210.20
S26° 18' 31"W259.00
OPEN SPACE
A = 15.08 ACRE
LOT: 13
AREA : 23,361 S.F.
LOT: 15
AREA : 25,153 S.F.
LOT: 16
AREA : 24,538 S.F.
LOT: 17
AREA : 24,884 S.F.
LOT: 18
AREA : 24,205 S.F.
LOT: 19
AREA : 24,175 S.F.
LOT: 20
AREA : 27,416 S.F.
LOT: 21
AREA : 29,578 S.F.
LOT: 22
AREA : 22,509 S.F.
LOT: 23
AREA : 22,491 S.F.
LOT: 24
AREA : 22,557 S.F.
LOT: 25
AREA : 22,301 S.F.
LOT: 26
AREA : 22,131 S.F.
LOT: 27
AREA : 29,913 S.F.
LOT: 28
AREA : 33,927 S.F.
LOT: 14
AREA : 24,001 S.F.
LOT: 5
AREA : 23,027 S.F.
LOT: 12
AREA : 23,345 S.F.
LOT: 11
AREA : 23,095 S.F.
LOT: 10
AREA : 31,931 S.F.
LOT: 9
AREA : 22,586 S.F.
LOT: 1
AREA : 23,832 S.F.
LOT: 2
AREA : 23,156 S.F.
LOT: 8
AREA : 22,532 S.F.
LOT: 7
AREA : 23,035 S.F.
LOT: 6
AREA : 22,902 S.F.
LOT: 4
AREA : 23,026 S.F.
LOT: 3
AREA : 23,025 S.F.
RESOURCE PROTECTION NOTE:
THIS SITE HAS BEEN REVIEWED FOR THE PRESENCE OF STEEP SLOPES, HILLTOPS
AND RIDGETOPS, SLIPPAGE SOILS, SPECIAL FLOOD HAZARDS, HISTORICAL AND
CULTURAL RESOURCES, AND KARST FEATURES. AREAS FALLING WITHIN THESE
CATEGORIES, IF ANY, HAVE BEEN NOTED ON THE PLAN AND CAN BE FOUND
ON THE NATURAL RESOURCE PROTECTION PLAN. THERE ARE NO HILLTOPS OR
RIDGETOPS IN THESE LOTS. THERE ARE NO SLIPPAGE SOILS INDICATED ON THE
PROPERTY BY THE NRCS WEB SOIL SURVEY. THERE ARE NO HISTORICAL OR
CULTURAL RESOURCES KNOWN ON THE PROPERTY.
05/05/202625051
REVISIONS
No. DATE WILSON BRANCH FARMS SUBDIVISION
CONCEPT PLAN
OLD MURFREESBORO ROAD,
WILLIAMSON COUNTY, TENNESSEE
7112 CROSSROADS BOULEVARD
SUITE 201
BRENTWOOD, TN 37027
(615) 873-1795
WWW.CRUNKENG.COM
CRUNK ENGINEERING LLC
Drawing Path: P:\2025\25051 - 3036 Old Murfreesboro Rd\Dwg\Construction\C2.0-LAY.dwg
WI LLIAM
W
. CRUNK
No. 115894
STATE OF
TENNESSEE
REGISTERED
ENGINEER
COMM
ERCE
AGRICULTURE
C2.0
OVERALL SITE
LAYOUT PLAN
NOTES:
1.REFER TO SHEET C2.3 FOR TYPICAL LOT LAYOUTS.
2.REFER TO SHEET C2.3 FOR LOT TABLES.
3.THIS PROPERTY HAS BEEN REVIEWED FOR THE EXISTENCE OF
INTERMITTENT AND PERENNIAL STREAMS. STREAMS THAT WOULD REQUIRE
WATERWAY NATURAL AREAS (WNA) AS DESCRIBED IN SECTION 4 OF THE
WILLIAMSON COUNTY STORM WATER MANAGEMENT REGULATIONS
HAVE BEEN LOCATED AS SHOWN.
4.WITHIN THE WATERWAY NATURAL AREA (WNA), THERE SHALL BE NO
CLEARING, GRADING, CONSTRUCTION, OR DISTURBANCE OF
VEGETATION EXCEPT AS PERMITTED BY THE WILLIAMSON COUNTY
ENGINEERING DEPARTMENT.
N
0
GRAPHIC SCALE
100200 50
1"=100'
CONCEPT PLAN
BOUNDARY
APPROXIMATE PATH OF 12' COMMUNITY
GREENWAY TRAIL WITH 15' EASEMENT (TYP)
CONCEPT PLAN
BOUNDARY
XX ROAD (PUBLIC DRIVE)
YY ROAD (PUBLIC DRIVE)
50 FT
OPEN SPACEBUFFER
50 FTOPEN SPACE
BUFFER
50 FT
WATERWAY NATURAL
AREA (WNA)
CRITICAL LOTS:
PROPOSED SINGLE FAMILY LOTS THAT HAVE
EXISTING CRITICAL SLOPES ARE INDICATED WITH
THIS SYMBOL. AN ENGINEERED SITE PLAN SHALL
BE SUBMITTED AND APPROVED BY WILLIAMSON
COUNTY ENGINEERING DEPARTMENT.
LOTS CURRENTLY CONTAIN CRITICAL SLOPES
WITH THE EXISTING TOPOGRAPHY ARE AS
FOLLOWS:
8, 20, 21, 22, 23, 24, 25, 26, AND 28.
ALL VERY STEEP SLOPES THAT ARE 5,000 SQUARE
FEET OR GREATER IN AREA ARE CONTAINED
WITHIN OPEN SPACE AREAS.
*
*
*
*
*
*
*
**
*
50 FTOPEN SPACE
BUFFER
PROPOSED WNA DISTURBANCE
8,450 SQ-FT / 0.19 AC
25 FTROW DEDICATION
TYPICAL GREENWAY TRAIL
STREAM CROSSING
TYPICAL GREENWAY TRAIL
STREAM CROSSING
APPROXIMATE PATH OF COMMUNITY
TRAIL WITH ROW ACCESS (TYP)
40 FTROW
15 FTPUD&AE
15 FTPUD&AE
APPROXIMATE PATH OF 12' COMMUNITY
GREENWAY TRAIL WITH 15' EASEMENT (TYP)
APPROXIMATE PATH OF 12' COMMUNITY
GREENWAY TRAIL WITH 15' EASEMENT (TYP)
APPROXIMATE LOCATION OF 15' GREENWAY
TRAIL EASEMENT FOR FUTURE CONNECTION
15 FT
15 FT
TRAIL ACCESS EASEMENT
12 FT
GREENWAY TRAIL
12 FTGREENWAY TRAIL
15 FT
TRAIL ACCESS EASEMENT
25 FTTRAIL ACCESS EASEMENT
25 FT
TRAIL ACCESS EASEMENT
25 FTTRAIL ACCESS EASEMENT
15 FTPUD&AE 15 FTPUD&AE
ATTACHMENT 25-1B
ATTACHMENT 25-2
Item 26—Page 1 of 2
Reviewer: OCW
Date: 5-14-2026
ITEM 26
PRELIMINARY PLAT REVIEW FOR CHESTNUT HIL L FARMS LLE SUBDIVIS ION,
CONTAINING 5 LOTS ON 28.50 ACRES LOCATED OFF WHIPPOORWILL DR IVE
IN THE 1ST VOTING DISTRICT (1-2025-324).
Attachment 26-1 Preliminary Plat
26-2 Aerial Photography
Area 28.50 acres
Lots 5
Zoning Municipal Growth Area–1 (MGA-1)
Water On-Site Wells
Sewer Individual On-Site Septic Systems
Development Option Large Lot Easement Subdivision
Chapter 1101 Status City of Fairview Urban Growth Boundary
File Number (1-2025-324)
The subject parcel is approximately twenty-eight (28) acres in size and is located off
Whippoorwill Drive , which is located in Cheatham County . The applicant is requesting
approval of a Large Lot Easement Subdivision in order to create five (5) lots off a new
ingress/egress/utilities easement. Cheatham County has approved the connection.
The site contains natural resources requiring protection, including wetlands and waterway
natural areas. All Zoning Ordinance requirements, including those regarding the
protection of natural resources, have been met.
The applicant is proposing individual septic systems for the lots, and the Williamson
County Department of Sewage Disposal Management has approved the reques t. As no
public water is available, water will be provided by on -site wells. As no fire hydrants are
proposed, building envelopes have been separated by 200 feet, and the fire apparatus
access requirements in Sec tion 3.05 (B) (2) (b) (ii) in the Subdivision Regulations must
be met.
The Preliminary Plat is in order and Staff recommends approval, subject to the following
conditions, which must be addressed in conjunction with Final Plat submittal:
1. A Land Disturbance Permit must be obtained for the overall development;
2. A Notice of Coverage issued by TDEC will be required prior to the issuance of a
Land Disturbance Permit;
Item 26---Page 2 of 2
Reviewer: OCW
Date: 5-14-2026
3. Prior to submittal of the Final Plat, driveway and drainage infrastructure must be
complete, consistent with Zoning Ordinance requirements; and
4. Satisfaction of Section 3.05 of the Subdivision Regulations, as it pertains to fire
apparatus access requirements.
ATTACHMENT 26-1A
ATTACHMENT 26-1B
ATTACHMENT 26-2
Item 27—Page 1 of 2
Reviewer: OCW
Date: 5-14-2026
ITEM 27
PRELIMINARY PLAT REVIEW FOR JOYBELLE ESTATES SUBDIVISION,
CONTAINING 12 LOTS ON 110.1 ACRES LOCATED OFF EUDAILEY-COVINGTON
ROAD IN THE 2ND VOTING DISTRICT (1-2026-304).
Attachment 27-1 Preliminary Plat
27-2 Aerial Photograph
Area 110.1 acres
Lots 12
Zoning Rural Development–5 (RD-5)
Water Milcrofton Utility District
Sewer Individual On-Site Septic
Development Option Major Traditional Subdivision
Chapter 1101 Status Rural
Map and Parcel 141---051.00
File Number (1-2026-304)
A Concept Plan for this development was approved by this body at the November 2025
meeting. The applicant is now requesting Preliminary Plat approval for the development,
which contains twelve (12) lots and approximately 14.21 acres of Open Space. The plat
is consistent in layout with the revised Concept Plan.
Staff recommends approval of the Preliminary Plat with the following conditions, which
must be addressed in conjunction with the Final Plat submittal:
1. Prior to consideration of Final Plat approval, the applicant shall submit HOA
documents for review and approval by the County Attorney’s office. The HOA
documents shall address the requirements of Section 17.12: Private Streets of the
Zoning Ordinance. The HOA documents must be submitted with the Final Plat,
and the approved HOA documents must be recorded concurrently with the
recording of the Final Plat;
2. A permit for the security gate will need to be obtained prior to its installation, and
all requirements for such gates as outlined in Section 17.11 of the Zoning
Ordinance must be met;
3. Establishment of a performance bond for roads, drainage and erosion control;
4. Establishment of a performance bond for water impro vements in favor of
Milcrofton Utility District;
Item 27---Page 2 of 2
Reviewer: OCW
Date: 5-14-2026
5. Submission of landscaping plans and establishment of a performance bond for
landscaping improvements;
6. Dedication of right -of-way twenty -five (25) feet off the centerline of Eudailey-
Covington Road;
7. Execution of Performance Agreements for the above-referenced sureties;
8. Execution of a Stormwater Maintenance Agreement and submission of an
Operation and Maintenance Plan for stormwater improvements; and
9. Submission of the approved Final Plat in .dwg format on reco rdable media based
on the Tennessee State Plane Coordinate System prior to signature and recording
of the plat.
GAS
GAS
GAS
GAS
GAS
GAS
W
W
W
W
W
W
W
W
S7°43'57"W 939.92'
ROW DEDICATION:
14,588.54 SQ. FT.
TENNESSEE SOCCER
CLUB, INC.
MAP 142 PARCEL 15.04
BOOK 9642, PAGE 669
BOLTON REV LIV TRUST
MAP 141 PARCEL 52.02
BOOK 9360, PAGE 129STEPHEN & ALEXANDRA
KARPENKO
MAP 141 PARCEL 52.03
BOOK 9208, PAGE 217
GREGORY & MARY STONE
MAP 141 PARCEL 52.06
BOOK 6175, PAGE 863
JONATHAN & MONA HOLT
MAP 141 PARCEL 52.04
BOOK 6162, PAGE 30
WILLIAM PATRICK &SHARON THOMPSON REV
TRUST
MAP 141 PARCEL 52.07
BOOK 9377, PAGE 218
LOOPE FAMILY TRUST
MAP 141 PARCEL 52.05
BOOK 9289, PAGE 561
MILLER CULBERSON
MAP 158 PARCEL 1.00
BOOK 5011, PAGE 487
ROSEMARY SHEARER
NOLEN ETAL
MAP 157 PARCEL 26.04
BOOK 6335, PAGE 466
TRACT 1
L66
50' ROW
50' ROW
50' ROW
50' ROW
60' ROW
EUDAILEY COVINGTON RD
TENNESSEE SOCCER
CLUB, INC.
MAP 142 PARCEL 15.04
BOOK 9642, PAGE 669
JOYBELLE LANE
(50' PRIVATE)
12
3
10
4
11
5
6
O.S. 1
7
8
1
2
9
O.S. 2
JOYBELLE LANE(50' PRIVATE)
S80°21'00"E 503.62'
S9°40'54"W
1352.83'
S1°13'03"E 728.22'S26°21'50"E 343.73'
S83°53'23"E 2122.41'
S12°25'28"W 630.18'
S79°59'32"E 542.73'
N1°29'37"W 540.39'N27°14'49"W 395.24'
N86°24'42"W 601.22'
N8°29'43"W 494.74'
N0°31'20"E 483.80'
S6°07'34"W 376.47'
S6°07'34"W 419.69'
S6°07'34"W 387.18'
N60°20'25"E 730.54'
N79°34'59"E 439.41'
S76°18'02"E 713.50'
S80°18'23"E 453.98'
S80°21'00"E 362.85'
L1
L2
L3
L4
L5
L6
L7L8
L9
L10
L11
L12L13
L14
L15L16
L17L18
L19L20
L21
L22
L23
L24
L25
L26
L27
L28
L29
L30
L31
L33 L32
L34
L35
L36
L37
L38
L39
L40
L41
L42
L43
L44 L45
L46L47
L48
L49
L50
L67
L68
L69
L70
L71
L72
L73
L74
L75
L76
L77
L78
L79
L80L81
L82
L83L84L85
L86
L87
L88
L89
L90
L91
L92
L93
L94
C1C2
L95L96
671.83'
C3
C4
L51
L100
L97
L99
N66°34'51"W 440.69'
L98
S9°54'18"W 380.53'
N9°54'18"E 380.97'
C24
C5
C6
C7C8
L52
L53
C9
C10
L54
C11L55L56C12
C13
C14
L57
L58
C15
C16
C17
C18
C19
L59
L60
C20 L61 L62 C21
L63
L64
C22
L65
C23
Parcel Area Table
Parcel #
1
2
3
4
5
6
7
8
9
10
11
12
Area (SF)
218044.98'
217917.21'
252458.23'
359760.76'
271647.74'
244558.67'
294610.08'
218099.70'
217592.25'
244068.25'
257605.30'
300732.37'
Area (AC)
5.01
5.00
5.80
8.26
6.24
5.61
6.76
5.01
5.00
5.60
5.91
6.90
Open Space Area Table
Parcel #
O.S. 1
O.S. 2
TRACT 1
Area (SF)
548599.14'
84233.65'
874173.31'
Area (AC)
12.59
1.93
20.07
Parcel Line Table
Line #
L1
L2
L3
L4
L5
L6
L7
L8
L9
L10
L11
L12
L13
L14
L15
L16
L17
L18
L19
L20
L21
L22
L23
L24
L25
L26
Length
79.92'
136.44'
207.30'
84.20'
302.27'
268.93'
342.59'
38.52'
32.14'
20.56'
50.22'
29.79'
79.94'
43.32'
31.42'
55.88'
34.98'
40.88'
33.89'
36.70'
34.81'
39.96'
46.68'
25.84'
31.65'
65.22'
Direction
N80°46'54"W
N80°21'00"W
N5°10'09"E
N19°47'52"E
N7°50'26"E
N7°46'49"E
N7°47'25"E
S88°06'49"W
S67°11'28"W
S81°39'23"W
N79°56'51"W
N85°33'56"W
N83°03'34"W
N83°42'14"W
N78°49'01"W
N86°52'07"W
N82°02'52"W
N85°30'02"W
N68°06'02"W
N75°21'53"W
N52°28'48"W
N57°52'11"W
N61°37'31"W
N77°46'06"W
N50°11'29"W
N57°18'11"W
Parcel Line Table
Line #
L27
L28
L29
L30
L31
L32
L33
L34
L35
L36
L37
L38
L39
L40
L41
L42
L43
L44
L45
L46
L47
L48
L49
L50
L51
L52
Length
36.74'
20.08'
31.12'
22.00'
50.36'
22.27'
37.53'
14.25'
18.11'
18.93'
50.29'
43.79'
95.12'
56.92'
16.32'
50.83'
18.22'
34.17'
15.13'
32.81'
33.78'
62.46'
67.48'
38.69'
25.00'
174.13'
Direction
N42°44'23"W
N26°32'04"W
N31°46'30"W
N51°30'09"W
N70°58'18"W
N40°11'12"W
N18°14'58"W
S84°57'16"W
S48°37'10"W
N65°38'15"W
N47°03'44"W
N38°50'34"W
N42°39'08"E
N55°06'40"E
S76°35'32"E
S84°29'33"E
N66°27'55"E
N28°47'43"E
N27°48'16"W
N13°44'14"W
N45°13'53"W
N30°31'11"W
S79°42'57"E
S79°42'57"E
S9°40'54"W
S29°33'33"E
Parcel Line Table
Line #
L53
L54
L55
L56
L57
L58
L59
L60
L61
L62
L63
L64
L65
L66
L67
L68
L69
L70
L71
L72
L73
L74
L75
L76
L77
L78
Length
173.90'
265.66'
292.05'
100.49'
175.87'
448.54'
352.35'
272.06'
103.58'
288.96'
225.46'
40.20'
348.04'
25.00'
313.79'
130.78'
366.22'
65.09'
448.30'
166.28'
116.85'
235.42'
467.44'
210.47'
420.78'
130.51'
Direction
S29°33'33"E
S22°13'27"W
S1°54'44"W
S1°54'44"W
S82°59'42"E
S82°59'42"E
N82°59'42"W
N82°59'42"W
N1°54'44"E
N1°54'44"E
N22°13'27"E
N22°13'27"E
N29°33'33"W
N9°39'00"E
N38°33'32"W
N5°26'31"W
N82°12'20"W
S80°46'54"E
N9°40'54"E
N80°18'23"W
N16°19'59"W
N82°09'15"W
N9°40'54"E
N79°26'21"E
N9°40'54"E
N87°40'16"W
Parcel Line Table
Line #
L79
L80
L81
L82
L83
L84
L85
L86
L87
L88
L89
L90
L91
L92
L93
L94
L95
L96
L97
L98
L99
L100
Length
209.68'
176.10'
138.80'
401.80'
324.46'
398.99'
150.98'
175.88'
194.69'
398.06'
220.64'
663.18'
140.27'
497.35'
527.12'
54.93'
440.83'
23.79'
63.53'
100.00'
340.00'
80.02'
Direction
S80°26'54"W
S13°13'20"E
S82°16'53"W
N84°09'39"W
N1°13'03"W
N1°13'03"W
N26°21'50"W
S87°54'00"E
N26°21'50"W
N12°25'28"E
N12°25'28"E
N83°53'23"W
S40°10'14"W
N83°53'23"W
N83°53'23"W
S6°07'34"W
N83°53'23"W
N35°23'12"W
N80°21'00"W
N80°21'00"W
N80°21'00"W
N80°46'54"W
Curve Table
Curve #
C1
C2
C3
C4
C5
C6
C7
C8
C9
C10
C11
C12
C13
C14
C15
C16
C17
C18
C19
C20
C21
C22
C23
C24
Length
148.67'
35.30'
154.41'
74.22'
28.98'
10.40'
158.44'
185.95'
149.59'
189.33'
150.36'
178.30'
191.40'
260.12'
37.85'
51.38'
188.50'
49.55'
37.85'
555.72'
132.94'
384.11'
309.95'
39.16'
Radius
694.00'
100.00'
168.00'
250.00'
25.00'
25.00'
500.00'
500.00'
375.00'
375.00'
425.00'
425.00'
425.00'
425.00'
45.00'
60.00'
60.00'
60.00'
45.00'
375.00'
375.00'
425.00'
450.00'
25.00'
Delta
12° 16' 28"
20° 13' 40"
52° 39' 33"
17° 00' 33"
66° 25' 19"
23° 49' 59"
18° 09' 19"
21° 18' 31"
22° 51' 21"
28° 55' 39"
20° 16' 15"
24° 02' 12"
25° 48' 10"
35° 04' 05"
48° 11' 15"
49° 03' 59"
180° 00' 00"
47° 18' 47"
48° 11' 31"
84° 54' 26"
20° 18' 43"
51° 47' 00"
39° 27' 51"
89° 44' 42"
Chord Direction
N73° 51' 18"W
N57° 36' 14"W
N21° 09' 37"W
N3° 20' 07"W
S47° 08' 21"E
S2° 00' 42"E
S0° 49' 38"W
S18° 54' 17"E
S18° 07' 52"E
S7° 45' 38"W
S12° 05' 20"W
S10° 06' 22"E
S35° 01' 33"E
S65° 27' 40"E
S58° 54' 05"E
S59° 20' 26"E
N6° 07' 34"E
S72° 28' 11"W
S72° 54' 33"W
N40° 32' 29"W
N12° 04' 06"E
N3° 40' 03"W
N9° 49' 37"W
N54° 46' 39"E
Chord Length
148.39'
35.12'
149.03'
73.94'
27.39'
10.32'
157.77'
184.88'
148.60'
187.33'
775.39'
176.99'
189.78'
256.08'
36.74'
49.83'
120.00'
48.15'
36.74'
506.24'
132.25'
371.17'
303.86'
35.28'
PROJECT NAME
PROJECT NUMBER
ADDRESS
PARCEL ID
EXISTING ZONING
PROPOSED ZONING
EXISTING SITE AREA
PROPOSED SITE AREA
PROPOSED ROW
ROW DEDICATION
PROPOSED LOTS
MAXIMUM GROSS DENSITY
PROPOSED DENSITY
MINIMUM LOT AREA
MINIMUM LOT WIDTH
JOYBELLE ESTATE
25-2423
6615 EUDAILEY-COVINGTON ROAD
MAP 141 - PARCEL 51.00
RD-5
RD-5
110.1 ACRES
90.1
4.3 ACRES
0.33 ACRES
12
1 LOT / 5 ACRES
0.67 LOTS / 5 ACRES
5 ACRES
200'
SITE DATA
SETBACKS
FRONT
SIDE
REAR
100'
25'
50'
RESOURCE PROTECTION
REQUIRED OPEN SPACE
PROPOSED OPEN SPACE
REQ. TREE CANOPY RET.
PRO. TREE CANOPY RET.
WETLANDS
ISOLATED WETLANDS REMOVAL
15% (13.51 ACRES)
16% (14.21 ACRES)
69% (16.35 ACRES)
96% (22.7 ACRES)
6.3 ACRES
1.87 ACRES
IRON PIN FOUND
IRON PIN SET
CONC. MON. FOUND
CONC. MON. SET
CONTROL POINT FOUND
CONTROL POINT SET
BENCH MARK
WATER METER
WATER VALVE
LEGEND
FIRE HYDRANT
SANITARY SEWER MH
SANITARY SEWER CO
AREA DRAIN
CURB INLET
STORM MH
ELECTRIC METER-BOX
ELECTRIC MH
LIGHT POLE
UTILITY POLE
GUY ANCHOR
COMMUNICATION BOX
COMMUNICATION MH
GAS METER
GAS VALVE
EVERGREEN TREE
SIDEWALK
MIN. BUIDLING SETBACK
M.B.S.L
PUBLIC UTIL. & DRAIN ESMT. P.U.D.E.
ADDRESSES1234
HANDICAP SPACE
SANITARY SEWER
WATER
UNDERGROUND ELEC
OVERHEAD ELEC
GAS
COMMUNICATIONS
8" SA
4" W
UGE
OHE
BOUNDARY
CENTERLINE
FENCE
WATER FEATURE
TREE LINE
4" G
COM
X
NO. DATE COMMENT
108 Beasley Drive
Franklin, TN
37064
615.794.2275
1 3/16/26 COMMENTS FROM COUNTY
2 3/30/26 WILCO ENGINEERING COMMENTS
3 4/24/26 WILCO ENGINEERING COMMENTS
JOYBELLE ESTATES
6615 EUDAILEY-COVINGTON ROAD
MAP 141 - PARCEL 51.00
WILLIAMSON COUNTY, COLLEGE GROVE, TENNESSEE
C2.3 PRELIMINARY PLAT - OVERALL
1000 N 537029.002 E 1756686.710 EL 863.88 RBCS OFFSITE
1001 N 536716.511 E 1757725.202 EL 827.18 RBCS TARGET
1002 N 535430.990 E 1757655.635 EL 813.80 RBCS TARGET
1003 N 534140.561 E 1757526.131 EL 747.94 RBCS TARGET
1004 N 533967.946 E 1759463.113 EL 740.78 RBCS TARGET
1005 N 533815.177 E 1760083.392 EL 727.59 RBCS TARGET
1006 N 533602.866 E 1759962.032 EL 727.51 RBCS TARGET
1007 N 536353.646 E 1759817.119 EL 787.63 RBCS OFFSITE
1008 N 534229.638 E 1761479.336 EL 724.06 RBCS OFFSITE
1010 N 531385.320 E 1757454.980 EL 755.37 RBCS OFFSITE
1011 N 533567.799 E 1756255.824 EL 775.09 RBCS OFFSITE
1012 N 535139.591 E 1756659.797 EL 775.84 RBCS OFFSITE
PROJECT CONTROL: TENNESSEE STATE PLANE COORDINATES.
NAD83, GEOID 03 ZONE 7 REVISED. NO DATUM ADJUSTMENT.
CONTROL TABLE
GRAPHIC SCALE 1:200
400' 200' 0' 200' VICINITY MAP
NOT TO SCALE
SITE
PLAT NOTES
1. THE PURPOSE OF THIS PLAT IS TO CREATE 12 LOTS FOR
FUTURE DEVELOPMENT, 2 OPEN SPACES, AND 1 TRACT.
2. SUBJECT PROPERTY IS PRESENTLY IDENTIFIED AS ALL OF
PARCEL 51.00 , ON WILLIAMSON COUNTY TAX MAP 141.
SAID PARCELS ARE FURTHER IDENTIFIED AS THE
PROPERTY DESCRIBED IN DEED BOOK 7940, PAGE 377,
REGISTERS OFFICE OF WILLIAMSON COUNTY, TENNESSEE
3. ZONING: RD-5 (RURAL DEVELOPMENT - 5)
4. BEARINGS AND COORDINATES SHOWN HEREON ARE
BASED ON THE TENNESSEE STATE PLANE COORDINATE
SYSTEM NAD83 (2011 US SURVEY FEET). ELEVATIONS
SHOWN HEREON ARE BASED ON NAVD88.
5. BY SCALED MAP LOCATION AND GRAPHIC PLOTTING ONLY,
THIS PROPERTY LIES WITHIN ZONE “X” AS DESIGNATED ON
CURRENT FEDERAL EMERGENCY MANAGEMENT AGENCY
MAP NO. 47187C0390G, WITH AN EFFECTIVE DATE OF
DECEMBER 20, 2024, WHICH MAKES UP A PART OF THE
NATIONAL FLOOD INSURANCE PROGRAM. ZONE “X” IS AN
AREA DETERMINED TO BE OUTSIDE THE 0.2% ANNUAL
CHANCE FLOODPLAIN.
6. I HEREBY CERTIFY THAT THIS IS A CATEGORY IV SURVEY
AND WAS CONDUCTED IN ACCORDANCE WITH RULE
0820-03.11 (GLOBAL POSITION SYSTEMS SURVEYS)
ACCORDING TO THE CURRENT TENNESSEE MINIMUM
STANDARDS OF PRACTICE AS PROMULGATED BY THE
TENNESSEE STATE BOARD OF EXAMINERS FOR LAND
SURVEYORS. THIS SURVEY WAS CONDUCTED WITH
DUAL-FREQUENCY RTK GPS EQUIPMENT BASED ON THE
TDOT CORPS NETWORK.
a. POSITIONAL ACCURACY: 0.07'
b. DATE OF SURVEY: 10/20/08
c. DATUM/EPOCH: TENNESSEE STATE PLANE NAD83
(2011 US SURVEY FEET). OCCUPATIONS FOR
CONTROL POINTS ARE 3 MINUTES EACH, SIDE SHOTS
ARE 3 SECONDS.
d. GEOID 3, ZONE 7 REVISED
e. NO COMBINED GRID FACTORS WERE USED.
7. ALL CORNERS SHOWN ON THE FACE OF THE SURVEY WILL
BE SET WITH 5/8 IRON ROD WITH CAP BEARING THIS
SURVEYORS COMPANY NAME.
8. MAINTENANCE OF ALL STORMWATER MANAGEMENT
FEATURES SHALL BE THE RESPONSIBILITY OF THE
PROPERTY OWNER(S) OR THE HOA.
9. NO OBSTRUCTIONS OR ENCROACHMENTS WHICH IMPEDE
THE FLOW OF STORMWATER SHALL BE PERMITTED WITHIN
PUBLIC DRAINAGE EASEMENTS. WILLIAMSON COUNTY IS
NOT RESPONSIBLE FOR REPAIR OR REPLACEMENT OF
ANY ENCROACHMENTS THAT ARE DAMAGED OR REMOVED
IN THE COURSE OF MAINTENANCE ACTIVITY WITHIN
EASEMENTS.
10. WITHIN THE WATERWAY NATURAL AREA, THERE SHALL BE
NO CLEARING, GRADING, CONSTRUCTION OR
DISTURBANCE OF VEGETATION EXCEPT AS PERMITTED BY
THE WILLIAMSON COUNTY ENGINEERING DEPARTMENT.
11. THIS SITE HAS BEEN REVIEWED FOR THE PRESENCE OF
STEEP SLOPES, HILLTOPS AND RIDGETOPS, SLIPPAGE
SOILS, AND KARST FEATURES. BUILDING AREAS FOR LOTS
1, 2, AND 3 HAVE BEEN IDENTIFIED AS HAVING STEEP
SLOPES.
12. THIS PROPERTY HAS BEEN REVIEWED FOR THE
EXISTENCE OF INTERMITTENT AND PERENNIAL STREAMS.
STREAMS THAT WOULD REQUIRE A WATERWAY NATURAL
AREA AS DESCRIBED IN SECTION 4 OF THE WILLIAMSON
COUNTY STORM WATER MANAGEMENT REGULATIONS
HAVE BEEN LOCATED AS SHOWN.
13.NO PORTION OF THIS PROPERTY IS LOCATED IN AN AREA
DESIGNATED AS A 100 YEAR FLOOD ZONE AS EVIDENCED ON
FEMA PANEL #47187C0390G OF WILLIAMSON COUNTY, TN, DATED
12/20/2024.
14.SOIL MAP REASSESSMENT WAS APPROVED BY WILLIAMSON
COUNTY SEWER DEPARTMENT ON 2/23/26.
ROW DEDICATION
WNA 50' FROM TOP OF BANK
HATCH LEGEND
4/24/2026
ATTACHMENT 27-1
ATTACHMENT 27-2
Item 28—Page 1 of 2
Reviewer: LS
Date: 5-14-2026
ITEM 28
PRELIMINARY PLAT REVIEW FOR CREEKBEND MANOR (AKA 8828 HORTON
HIGHWAY) LARGE LOT EASEMENT SUBDIVISION , CONTAINING 5 LOTS ON
28.01 ACRES LOCATED OFF HORTON HIGHWAY IN THE 2ND VOTING DISTRICT
(1-2025-334)
Attachment 28-1 Preliminary Plat
28-2 Aerial Photograph
28-3 Variance Request for Flood Plain Disturbance
28-4 Variance Request for Easement Setback Encroachment
Area 28.01 acres
Zoning College Grove Village (CGV)
Lots 5
Water Nolensville/College Grove Utility District
Sewer Individual On-Site Septic Systems
Development Option Large Lot Easement
Chapter 1101 Status Rural
Map and Parcel 158---04302
File Number (1-2025-334)
The subject parcel is 28.01 acres in size and is located off Horton Highway. The applicant
is requesting approval of a Large Lot Easement Subdivision in order to create five (5) lots
off a new fifty-foot (50’) ingress/egress/utilities easement.
The site contains natural resources requiring protection, including steep slopes, 100-year
flood plain, Waterway Natural Areas (WNAs), and tree canopy. All Zoning Ordinance
requirements, including those regarding the protection of natural resources, have been
met.
The applicant is proposing individual on-site septic systems for the lots, and the
Williamson County Department of Sewage Disposal Management has approved the
request. Water will be provided by the Nolensville/College Grove Utility District. As no
fire hydrants are proposed, building envelopes have been separated by 200 feet as
required in Section 3.05 (B) (2) (b) (i) of the Subdivision Regulations , and fire sprinkler
systems shall be provided in all habitable structures.
The lots in question will take access from an existing fifty -foot (50’) easement that
extends from Horton Highway across the floodplain and one (1) other property. In order
for the easement to transverse the floodplain and to construct the necessary bridge to
cross Overall Creek, a Floodplain Development Permit (FDP) is required. The FDP has
been submitted and is under review by the Engineering Department. Section 3.04 (D) of
Item 28—Page 2 of 2
Reviewer: LS
Date: 5-14-2026
the Subdivision Regulations prohibits buildings or structures within floodplain, and as
such, a variance from this requirement is needed in order for the Engineering Department
to approve and issue the FDP. The Engineering Department supports the variance
request.
The existing easement was created in 2025 and does not meet the minimum separation
requirement of five (5) feet . Section 3.02 (D)(2)(b) of the Subdivision Regulations
requires all access easements be set back a minimum of five (5) feet from adjacent
parcels that will not access the easement. The applicant is requesting a variance from
this Section so as not to be required to relocate the easement to meet the five (5) foot
setback requirement from adjacent parcels that do not access the easement (See
Attachment 28-4). Because the easement was created in 2025 and the five (5) foot
setback was required from adjoining properties at the time, Staff does not support the
variance request.
The Preliminary Plat is in order , and so long as the Planning Commission grants the
requested v ariances, Staff recommends approval, subject to the following conditions,
which must be addressed in conjunction with Final Plat submittal:
1. A Notice of Coverage issued by TDEC will be required prior to the issuance of a
Land Disturbance Permit;
2. Satisfaction of Section 3.05 of the Subdivision Regulations, as it pertains to fire
sprinkler systems in habitable structures on all lots;
3. Establishment of a Performance Bond for water improvements in favor of
Nolensville/College Grove Utility District;
4. Submission of road names for review and approval by the Williamson County
Emergency Management Agency (EMA);
5. A Land Disturbance Permit must be obtained for the overall development; and
6. Prior to submittal of the Final Plat, driveway and drainage infrastructure must be
complete, consistent with Zoning Ordinance requirements. The applicant shall
notify Staff in order to conduct the required inspection.
0 100 200 300
HOMELAND SURVEYING
& MAPPING, LLC
PRELIMINARY PLAT
OF
CREEKBEND MANOR
COLLEGE GROVE, TN. 37046
ti ati
ti
ti
ti
ti ti
ti
ti
ti
ti ti ti
ti
ti
ti ti
ti
ti ti ti
ti
ti ti ti
ti ti ti ti
ti ti
ti ti
’
’
T28
100 FT
W
ATERW
AY NATURAL AREA
50 FT
W
NA BUFFER
50 FT
WNA BUFFER
100 FT WATERWAY NATURAL
AREAWNA BUFFER
LOT 5 PRIMARY PRINCIPAL
SSDS AREA RESTRICTED TO
ONE 5 BEDROOM
CONVENTIONAL. LPP
BEDROOM COUNT TBD BY
FIELD LAYOUT
EGAM, OVERWASH WDD
75 MPI TO 24" - LPP
WDD TO 36"
0-5% SLOPES
9,825 SQFT. / 0.23 ACRES
10,005 SQFT. / 0.23 ACRES
LOT 1 PRIMARY PRINCIPAL
SSDS AREA RESTRICTED TO
ONE 5 BEDROOM
CONVENTIONAL. LPP
BEDROOM COUNT TBD BY
FIELD LAYOUT
EGAM, OVERWASH WDD
75 MPI TO 24" - LPP
WDD TO 36"
0-5% SLOPES
9,899 SQFT. / 0.23 ACRES
10,109 SQFT. / 0.23 ACRES
13,056 SQFT. / 0.30 ACRES
LOT 2 PRIMARY PRINCIPAL
SSDS AREA RESTRICTED TO
ONE 8 BEDROOM
CONVENTIONAL OR LPP
SYSTEM
MARSH
45 MPI TO 24" - LPP
5-15% SLOPES
14,024 SQFT. / 0.32 ACRES
LOT 3 PRIMARY PRINCIPAL
SSDS AREA RESTRICTED TO
ONE 5 BEDROOM 5 BEDROOM
CONVENTIONAL. LPP
BEDROOM COUNT TBD BY
FIELD LAYOUT
STIVERSVILLE
30 MPI TO 24" - LPP
5-15% SLOPES
7,322 SQFT. / 0.17 ACRES
6,556 SQFT. / 0.15 ACRES
LOT 4 PRIMARY PRINCIPAL SSDS
AREA RESTRICTED TO ONE 5
BEDROOM CONVENTIONAL.
LPP BEDROOM COUNT TBD BY
FIELD LAYOUT
STIVERSVILLE
30 MPI TO 24" - LPP
15-25% SLOPES
8,729 SQFT. / 0.20 ACRES
8,495 SQFT. / 0.20 ACRES
O12
L12
O9
Q9
R12
T12
Q11
S8
P8
N7
M10
O14
U30
T30T28
Q33
S32
R31
N28
L29 L31
I29
K28
J28J26J25
I24
L26
K25
L24
D
E
E
D
B
C
B
A
F
G
I
FG
H
A
K
C
H
J
I
J
CREEK BOUNDARY
CREEK BOUNDARY
●
●
●
●
●
ATTACHMENT 28-1
Item 29—Page 1 of 1
Reviewer: JYJ
Date: 5/14/2026
ITEM 29
SITE PLAN REVIEW FOR THE ARBORS AT LEIPERS FORK SUBDIVISION
AMENITY CENTER, ON 51.41 ACRES, LOCATED OFF HARGROVE ROAD IN THE
1ST VOTING DISTRICT (5-2026-002).
Attachments 29-1 Site Plan
29-2 Aerial Photograph
Area 51.41 acres
Zoning Rural Development–5 (RD-5)
Water HB & TS Utility District
Sewer Individual On-site Septic Systems
Development Options Private Recreational Center
Chapter 1101 Status Rural
Map and Parcels 094—038.17
File Number (5-2026-002)
The applicant is requesting Site Plan approval for an amenity center for the A rbors at
Leipers Fork subdivision, which will be located in Open Space and contains a sports court
with a pavilion, a small playground, a pavilion and fire pit, sidewalks, trails and a parking
lot. Natural Resource Protection standards have been met.
Pursuant to Section 11.03 (D)(8) of the Zoning Ordinance, this Site Plan must be reviewed
by the Planning Commission at a public meeting. Amenity Centers embedded within
residential neighborhoods and located within Open Space are classified as Private
Recreational Centers, which are intended for the exclusive use of the residents of the
subdivision.
The requirements of S ection 11.03 (D)(8) have been met. There will be no water or
sewer service to the amenity center, and therefore no water or sewer bond is required.
The Site Plan is in order, and Staff recommends approval with the condition that the HOA
documents shall be revised to be consistent with the requirements and limitations of the
Private Recreational Center Use Type as described by the Zoning Ordinance.
Cut Slope Layout Mode
Fill Slope Layout Mode
Cut Slope Layout Mode
Fill Slope Layout Mode
COVER SHEET
C-0.0
6201 MAYVIEW PASS
MAP 94, PARCEL 38.17
FOR
THE ARBORS AT LEIPERS FORK
Franklin, Williamson County, Tennessee
SITE PLAN
N.T.S.
LOCATION MAP
DEVELOPER: C.E. Crews Jr./CC Trust
5600 BOY SCOUT RD
FRANKLIN, TN 37064
ENGINEER: T-SQUARE ENGINEERING
111 SE PARKWAY CT
FRANKLIN, TN 37064
WATER UTILITY: HB&TS
505 DOWNS BLVD.
FRANKLIN, TN 37064
SURVEYOR: T-SQUARE ENGINEERING
111 SE PARKWAY CT
FRANKLIN, TN 37064
SITE
APPLICANT
T-SQUARE ENGINEERING
111 SE PARKWAY CT
FRANKLIN, TN 37064
615.678.8212
FLOOD NOTE
NO PORTION OF THIS PROPERTY IS LOCATED IN AN AREA DESIGNATED AS A 100 YEAR FLOOD ZONE
AS EVIDENCED ON FEMA PANEL # 47187C0165F OF WILLIAMSON COUNTY, TN, DATED 09/29/2006 AND
FEMA PANEL # 47187C0170F OF WILLIAMSON COUNTY, TN, DATED 09/29/2006.
DATE
T-SQUARE
drawn by:
AS SHOWN
scale:
04/01/26
date: NO. REVISIONS
khm
reviewer:
SrRMect
21-0831-1
sheet
THE ARBORS AT LEIPERS FORK AMENITY CENTER
6201 MAYVIEW PASS, FRANKLIN, TN
MAP 94, PARCEL 38.17
WILLIAMSON COUNTY, TENNESSEE 37064
T-SQUAREENGINEERING
OWNER OF RECORD
BABY CE CREWS JR/BABY CC TRUST
555 GREAT CIRCLE ROAD, NASHVILLE, TN 37228
TAX MAP 94, PARCEL 38.17
DEED BOOK 9543, PAGE 557
KELSEY H. MAGEE
REGISTERED ENGINEER
No. 127740
COMMERCE
STATE OF TENNESSEE
AGRIC8LT8RE
04/13/2026
1 04/13/26 REVISIONS PER STAFF COMMENTS
Sheet Schedule
C-0.0 Cover Sheet
C-1.0 Existing Conditions
C-1.1 Resource Protection Plan
C-1.2 Slope Analysis
C-2.0 Site Plan
C-5.0 Grading & Roadway Plan and Profile
AMENITY CENTER
MAYVIEW PASS
LAUREL VALLEY DR
HARGROVE RD
P:\Projects\2021\21-0831 (Hargrove Rd. - Greg Templeton)\Production\Amenity Center\21-0831 2 Amenity Site Plan.dwg, 4/20/2026 3:16:00 PM
ATTACHMENT 29-1A
LEGEND
PROPOSED LOT LINES
PROPOSED LOT NUMBER
PROPOSED BUILDING SETBACK
PROPOSED ACCESS EASEMENT
PROPOSED WATER LINE
PROPOSED WATER SERVICE
00
LEGEND
PROPOSED LOT LINES
PROPOSED LOT NUMBER
PROPOSED BUILDING SETBACK
PROPOSED ROW DEDICATION
PROPOSED WATER LINE
PROPOSED WATER SERVICE
IRON PIN FOUND
W
25-FT SETBACK
25-FT SETBACK
25-FT SETBACK
25-FT SETBACK
B
E
C
D
AF
AB
C
D
E
F
G
H
J
D
E
F
G
H
E
F
100' MBSL
100' MBSL
104' MBSL
111' MBSL
4''W
4''W
4''W
4''W
4''W
4''W
4''W
4''W
4''W
4''W
4''W
4''W
4''W
4''W
4''W
4''W
4''W
4''W
4''W
4''W
4''W
4''W
4''W
4''W
4''W
0+00
1+00
2+00
3+003+03
4''W
4''W
4''W
4''W
4''W
4''W
4''W
4''W
C29
L18
C30
C46
C47
C48
C49
C50
C51
C52 L21
C53
S58° 46' 54"W
151.01'
N61° 20' 55"E395.04'
N27° 41' 23"E162.12'
N30° 05' 35"E419.04'
L381
L382
L383
L384
L385L386
L387
L388
L389
L390 L391
L392
L393
L394
L422
25' MBSL
FRONT OF PARCEL
N16° 56' 05"E
587.19'
S39° 05' 06"E
44.08'
N61° 20' 55"E320.22'
N61° 20' 55"E141.02'
S78° 49' 23"E
321.73'
N74° 37' 59"E
162.85'
S46° 06' 52"E
235.11'
C16
L7
C17
L9
C18
L11
C19
L13
C20
C21
L35
C55
L37
C59
L57
C60
L61
C61
C62
L63
AM-HW1
AM-HW2
SITE PLAN
C-2.0
GENERAL NOTES:
1. THIS PROPERTY HAS BEEN REVIEWED FOR THE EXISTENCE
OF INTERMITTENT AND PERENNIAL STREAMS. STREAMS
THAT WOULD REQUIRE WATERWAY NATURAL AREAS AS
DESCRIBED IN SECTION 4 OF THE WILLIAMSON COUNTY
STORM WATER MANAGEMENT REGULATIONS HAVE BEEN
LOCATED AS SHOWN.
2. THIS SITE HAS BEEN REVIEWED FOR THE PRESENCE STEEP
SLOPES, HILLTOPS AND RIDGETOPS, SLIPPAGE SOILS, AND
KARST FEATURES. AREAS FALLING WITHIN THESE
CATEGORIES WILL BE ADDRESSED PER THE WILLIAMSON
COUNTY ZONING CODE.
3. THIS SITE HAS BEEN REVIEWED FOR THE PRESENCE OF
KARST FEATURES. NO KARST FEATURES WERE FOUND
4. THIS SITE HAS BEEN REVIEWED FOR THE PRESENCE OF
STEEP SLOPES.
5. WITHIN THE WATERWAY NATURAL AREA, THERE SHALL BE
NO CLEARING, GRADING, CONSTRUCTION OR DISTURBANCE
OF VEGETATION EXCEPT AS PERMITTED BY THE WILLIAMSON
COUNTY ENGINEERING DEPARTMENT.
6. ALL NATURE TRAILS WILL BE MINIMUM 15FT OFF OF THE TOP
OF STREAM BANKS. THE NATURE TRAILS WILL BE
PERMEABLE AND WILL BE FIELD LOCATED PRIOR TO
CONSTRUCTION.
7. THE SITE HAS BEEN REVIEWED FOR SPECIAL FLOOD HAZARD
AREAS AND WETLAND AREAS, NONE FOUND ON SITE.
8. THE AMENITY CENTER IS LOCATED INTERNAL TO THE
SUBDIVISION IN OPEN SPACE-102 AS RECORDED IN BOOK
P86, PAGE 132 OF THE ARBORS AT LEIPERS FORK
SUBDIVISION, PHASE 1.
APPLICANT
T-SQUARE ENGINEERING
111 SE PARKWAY CT
FRANKLIN, TN 37064
615.678.8212
FLOOD NOTE
NO PORTION OF THIS PROPERTY IS LOCATED IN AN AREA DESIGNATED AS A 100 YEAR FLOOD ZONE
AS EVIDENCED ON FEMA PANEL # 47187C0165F OF WILLIAMSON COUNTY, TN, DATED 09/29/2006 AND
FEMA PANEL # 47187C0170F OF WILLIAMSON COUNTY, TN, DATED 09/29/2006.
DATE
T-SQUARE
drawn by:
AS SHOWN
scale:
04/01/26
date: NO. REVISIONS
khm
reviewer:
SrRMect
21-0831-1
sheet
THE ARBORS AT LEIPERS FORK AMENITY CENTER
6201 MAYVIEW PASS, FRANKLIN, TN
MAP 94, PARCEL 38.17
WILLIAMSON COUNTY, TENNESSEE 37064
T-SQUAREENGINEERING
OWNER OF RECORD
BABY CE CREWS JR/BABY CC TRUST
555 GREAT CIRCLE ROAD, NASHVILLE, TN 37228
TAX MAP 94, PARCEL 38.17
DEED BOOK 9543, PAGE 557
KELSEY H. MAGEE
REGISTERED ENGINEER
No. 127740
COMMERCE
STATE OF TENNESSEE
AGRIC8LT8RE
04/13/2026
1 04/13/26 REVISIONS PER STAFF COMMENTS
T.C.A.0400-45-09-.17
GEOTHERMAL WELL CONSTRUCTION STANDARDS FOR
CLOSED LOOP GEOTHERMAL BOREHOLES
SOURCE OF STRUCTURE MINIMUM DISTANCE
SEWER LINES 10 FEET
SEPTIC TANKS 25 FEET
SPRINGS 100 FEET
SEPTIC DRAIN FIELDS 25 FEET
WATER WELLS 100 FEET
HOUSE TO SEPTIC TO TANK CONNECTION 10 FEET
HOUSE TO SEWER CONNECTION 10 FEET
25' DRAINAGE
EASEMENT (TYP.)
MAYVIEW PASS (PVT)
( IN FEET )
GRAPHIC SCALE
0 50 10050 25
SCALE: 1" = 50'
LAUREL VALLEY DR (PVT)
CAROTENE COURT (PVT)
60' WNA BUFFER
60' WNA BUFFER
FORMAL LAWN
TRAIL
PLAYGROUND
SPORT COURT
PAVILION
PAVILION WITH FIREPLACE
RETAINING WALL -
DESIGNED BY OTHERS
RETAINING WALL -
DESIGNED BY OTHERS
STAIRS, TYP. -
6" RISER, 18" TREAD
6'
5'
5'
4'
4'
5'
5'
8'
8'
8'
14'
R5'
R5'R5'
R5'R5'
5'
11'
5'
5'
18'
9'
9'
15'
15'22'
22'15'R5'
R5'
5'
5'
19'
TRAIL
SITE DATA
MAP 94, PARCEL 38.17 EXISTING PROPOSED
TOTAL PROPERTY ACREAGE 51.41 51.41
ZONING RD-5 RD-5
USE OPEN
SPACE
OPEN
SPACE
MAXIMUM GROSS FLOOR AREA 1,225 SF
MAXIMUM BUILDING HEIGHT
25.7'
MINIMUM BUILDING HEIGHT
FRONT SETBACK 100'
SIDE SETBACK 25'
REAR SETBACK 50'
AUTOMOBILE PARKING SPACES 0 13
ADA PARKING SPACES 0 1 TOT, 1 VAN
PARKING CALCULATIONS:
1. RESIDENTIAL OPEN SPACE
1.1. REQUIRED: 26 LOTS *(1.0 SPACE PER 2
HOMES) = 13 SPACES
1.2. PROVIDED: 13 SPACES
NOTES:
1. ARBORS AT LEIPERS FORK IS A PRIVATE,
GATED SUBDIVISION WITH PRIVATE ROADS.
2. NO WASTEWATER AREAS ARE PROPOSED.
3. AMENITY CENTER IS FOR PRIVATE USE
WITHIN THE SUBDIVISION ONLY.
4. TOPOGRAPHIC INFORMATION PROVIDED BY
T-SQUARE SURVEYING, DATED 2/24/2026.
RESOURCE PROTECTION NOTE:
THIS SITE HAS BEEN REVIEWED FOR THE PRESENCE OF STEEP SLOPES, HILLTOPS AND
RIDGETOPS, SLIPPAGE SOILS, SPECIAL FLOOD HAZARDS, HISTORICAL AND CULTURAL
RESOURCES, AND KARST FEATURES. AREAS FALLING WITHIN THESE CATEGORIES, IF ANY,
HAVE BEEN NOTED ON THE RESOURCE PROTECTION PLAN. THERE HAVE BEEN NO KARST
FEATURES FOUND ON THIS PROPERTY. THERE ARE NO SLIPPAGE SOILS INDICATED BY THE
APPROVED SOIL MAP OR WC WEB SOIL SURVEY. THERE ARE NO HISTORICAL OR CULTURAL
RESOURCES KNOWN IN THESE LOTS. THERE IS NO HILLTOP/RIDGETOP ON THIS PROPERTY,
AS DETERMINED BY WC PLANNING DIRECTOR MICHAEL MATTESON.
THERE ARE STEEP SLOPES ON THE PROPERTY. VERY STEEP SLOPES (25% OR GREATER)
OF 5000 SF OR LARGER HAVE BEEN REMOVED FROM BUILDABLE AREAS. BUILDABLE AREAS
WITH MODERATELY STEEP SLOPES (15% - 25%) ARE LOCATED WITHIN THE PROPOSED
LIMITS OF DISTURBANCE. AN ENGINEERED SITE PLAN HAS BEEN PROVIDED WITHIN THE
CONSTRUCTION DOCUMENTS FOR THIS DEVELOPMENT.
HYDROLOGIC DETERMINATION REPORTS WERE COMPLETED BY BDY ENVIRONMENTAL ON
APRIL 15, 2022 AND MAY 19, 2022. 103 WATERWAYS AND CONVEYANCES WERE IDENTIFIED
ON THE PARENT PARCEL. THE LIMITS OF DISTURBANCE DOES NOT ENCROACH ON
WATERWAY NATURAL AREA BUFFERS. DRAINAGE AREAS GREATER THAN 5 ACRES HAVE
BEEN DELINEATED WITH A 25-FT DRAINAGE EASEMENT. THERE ARE NO WETLANDS
INDICATED ON THE REPORT.
THIS PROPERTY IS 100% (51.41 AC) COVERED IN EXISTING TREE CANOPY. PER REGULATION,
48% (24.68 AC) MUST BE PRESERVED IN THIS PHASE. 92.8% (50.51 AC) OF THE EXISTING TREE
CANOPY IS PROPOSED AS BEING PRESERVED. TOTAL TREE CANOPY DISTURBED BY
DEVELOPMENT IS 7.2% (0.9 AC).
103' TO R.O.W.
236' TO R.O.W.
144' TO R.O.W.
P:\Projects\2021\21-0831 (Hargrove Rd. - Greg Templeton)\Production\Amenity Center\21-0831 2 Amenity Site Plan.dwg, 4/20/2026 3:16:32 PM
ATTACHMENT 29-1B
ATTACHMENT 29-2
Item 30—Page 1 of 1
Reviewer: LS
Date: 5/14/2026
ITEM 30
PRELIMINARY PLAT REVIEW FOR DODD FAMILY REVOCABLE LIVING TRUST
SUBDIVISION, CONTAINING 1 LOT ON 32.12 ACRES LOCATED OFF
TALIAFERRO ROAD IN THE 5TH VOTING DISTRICT (1-2026-305).
Area 32.12 acres
Zoning Rural Development-5 (RD-5)
Lots 1
Water Nolensville/College Grove Utility District
Sewer Individual On-Site Septic Systems
Development Option Large Lot Easement
Chapter 1101 Status Rural
Map and Parcel 140---01414
File Number (1-2026-305)
At this time, the applicant is requesting deferral to the June 2026 Planning Commission
Meeting in order to allow the applicant more time to address Staff comments. Staff
concurs with this request.
Item 31—Page 1 of 2
Reviewer: LS
Date: 5/14/2026
ITEM 31
PRELIMINARY PLAT REVIEW FOR HALEY VALLEY LARGE LOT EASEMENT
SUBDIVISION, CONTAINING 5 LOTS ON 25.12 ACRES LOCATED OFF
MURFREESBORO ROAD IN THE 5TH VOTING DISTRICT (1-2026-307).
Attachment 31-1 Preliminary Plat
31-2 Aerial Photograph
Area 25.12 acres
Zoning Rural Development-5 (RD-5)
Lots 5
Water Nolensville/College Grove Utility District
Sewer Triune Sewer Facility
Development Options Large Lot Easement
Chapter 1101 Status Rural
Map and Parcels 113---05502 and 05403
File Number (1-2026-307)
The subject parcel is 2 5.12 acres in size and is located off Murfreesboro Road. The
applicant is requesting approval of a Large Lot Easement Subdivision in order to create
five (5) lots off a new fifty-foot (50’) ingress/egress/utilities easement. The easement has
TDOT-approved connection to Murfreesboro Road.
The site contains natural resources requiring protection, including steep slopes, wetlands,
Waterway Natural Areas (WNAs), and tree canopy. All Zoning Ordinance requirements,
including those regarding the protection of natural resources, have been met.
The applicant is proposing to connect the lots to Triune Sewer Facility, and Williamson
County’s wastewater consultant has confirmed sewer capacity and has recommended
approval from a wastewater standpoint . Water will be provided by Nolensville/College
Grove Utility District. Proposed fire hydrants meet the minimum flow rate of 500 gpm
and are located no further than 500 feet from all parts of all building envelopes.
The Preliminary Plat is in order, and Staff recommends approval, subject to the following
conditions, which must be addressed in conjunction with Final Plat submittal:
1. A Notice of Coverage issued by TDEC will be required prior to the issuance of a
Land Disturbance Permit;
2. Fire hydrants shall be installed and functioning and flow reports submitted proving
they meet the 500 gpm standard, prior to Final Plat approval;
Item 31—Page 2 of 2
Reviewer: LS
Date: 5/14/2026
3. Establishment of a Performance Bond for water improvements in favor of
Nolensville/College Grove Utility District;
4. Establishment of a performance bond for the wastewater collection system;
5. Submission of road names for review and approval by the Williamson County
Emergency Management Agency (EMA);
6. A Land Disturbance Permit must be obtained for the overall development; and
7. Prior to submittal of the Final Plat, driveway and drainage infrastructure must be
complete, consistent with Zoning Ordinance requirements. The applicant shall
notify Staff in order to conduct the required inspection.
154.68'
N77° 01' 11"E
154.68'
S12° 46' 37"E
525.96'
SCALE: 1"=100'
ARTICLE 13 RESOURCE PROTECTION NOTE:
SEWER SYSTEM EASEMENT NOTE:
Contact
Natalia Powell
Triune Development, LLC
P.O. Box 190 Arrington, TN 37014
(615) 395-0047
Developer:
1301 ASHBY VALLEY LANE
TRIUNE DEVELOPMENT, LLC
ARRINGTON, TN 37014
MAP 113- PARCELS 55.02 ,PART OF 54.02, 54.03 MAP 113-PARCEL 55.02 Book 9522, pg. 131
ZONED RD-5 ZONED RD-5
Owner:
1301 ASHBY VALLEY LANE
TRIUNE DEVELOPMENT, LLC (Jay Russ)
ARRINGTON, TN 37014
M
M
M
M
M
PO Box 1012
Smyrna, TN 37167-1012
(615) 347-5918
pjernigan@hfrsurvey.com
(615) 519-3935
dreagan@hfrsurvey.com
MAP 113- PARCEL54.03 MAP 113-PARCEL 54.03 BOOK 9956-PG 571
MAP 113- PARCEL PART OF 54.02 MAP 113-PARCEL PART OF 54.02 BOOK 9956-PG 575
10001
866.558
FN1 WOVEN WIRE/FENCE POST
10003
868.566
FN1
10006
871.254
FN1
10008
874.836
FN1
EXISTING
FARM
POND
EXISTING WETLAND BUFFER AREA (WTL-2)
EXISTING WETLAND BUFFER AREA
(WTL-2)
EXISTING WETLAND BUFFER
AREA (WTL-2)
EXISTING WETLAND
BUFFER AREA (WTL-2)
EXISTING
WETLAND
BUFFER AREA
(WTL-2)
EXISTING
WETLAND
BUFFER
AREA
(WTL-2)
EXISTING
WETLAND
BUFFER
AREA
(WTL-2)
EXISTING WETLAND
BUFFER AREA
(WTL-2)
EXISTING WETLAND BUFFER AREA (WTL-2)
EXISTING WETLAND BUFFER AREA (WTL-2)EXISTING WETLAND BUFFER AREA (WTL-2)EXISTING WETLAND BUFFER AREA (WTL-2)EXISTING
WETLAND
BUFFER AREA
(WTL-2)
EXISTING
WETLAND AREA
(WT-1)
EXISTING
WETLAND AREA
(WT-1)
EXISTING WETLAND AREA (WT-1)
EXISTING
WETLAND AREA
(WT-1)
EXISTING
WETLAND AREA
(WT-1)
EXISTING
WETLAND AREA
(WT-1)
EXISTING
WETLAND AREA
(WT-1)
EXISTING
WETLAND AREA
(WT-1)
EXISTING
WETLAND AREA
(WT-1)
EXISTING
WETLAND AREA
(WT-1)
EXISTING
WETLAND AREA
(WT-1)
EXISTING
WETLAND AREA
(WT-1)
EXISTING
WETLAND AREA
(WT-1)
EXISTING
WETLAND AREA
(WTL-2)
EXISTING
WETLAND AREA
(WTL-2)
EXISTING
WETLAND AREA
(WTL-2)
EXISTING
WETLAND AREA
(WTL-2)
EXISTING
WETLAND AREA
(WTL-2)
EXISTING
WETLAND AREA
(WTL-2) EXISTING
WETLAND AREA
(WTL-2)
EXISTING
WETLAND AREA
(WTL-2)
EXISTING
WETLAND AREA
(WTL-2)
EXISTING
WETLAND AREA
(WTL-2)
EXISTING
WETLAND AREA
(WTL-2)
EXISTING
WETLAND AREA
(WTL-2)
EXISTING
WETLAND AREA
(WTL-2)
EXISTING
WETLAND AREA
(WT-1)
EXISTING
WETLAND AREA
(WT-1)
EXISTING
WETLAND AREA
(WT-1)
EXISTING
WETLAND AREA
(WT-1)
EXISTING
WETLAND AREA
(WT-1)
EXISTING
WETLAND AREA
(WT-1)
EXISTING
WETLAND AREA
(WT-1)
EXISTING
WETLAND AREA
(WT-1)
EXISTING
WETLAND AREA
(WT-1)
EXISTING WETLAND AREA (WT-1)
EXISTING
WETLAND AREA
(WT-1)
EXISTING
WETLAND AREA
(WT-1)
EXISTING
WETLAND AREA
(WT-1)
EXISTING WETLAND BUFFER AREA (WTL-1)
EXISTING WETLAND BUFFER AREA
(WTL-1)
EXISTING WETLAND BUFFER
AREA (WTL-1)
EXISTING WETLAND
BUFFER AREA (WTL-1)
EXISTING
WETLAND
BUFFER AREA
(WTL-1)
EXISTING
WETLAND
BUFFER
AREA
(WTL-1)
EXISTING
WETLAND
BUFFER
AREA
(WTL-1)
EXISTING WETLAND
BUFFER AREA
(WTL-1)
EXISTING WETLAND BUFFER AREA (WTL-1)
EXISTING WETLAND BUFFER AREA (WTL-1)EXISTING WETLAND BUFFER AREA (WTL-1)EXISTING WETLAND BUFFER AREA (WTL-1)EXISTING
WETLAND
BUFFER AREA
(WTL-1)
06
E
AGRICULTURE
91
.
R YO
C
O
SSE
REG
ET
NN
CRM EM
NEE
E
O
RV
UER
TE
IS
NDLAD
IXV S
ATTACHMENT 31-1
Item 32—Page 1 of 1
Reviewer: LS
Date: 5/14/2026
ITEM 32
FINAL PLAT REVIEW FOR FOSTER SUBDIVISION FAMILY SUBDIVISION,
CONTAINING 1 LOT ON 1.40 ACRES LOCATED OFF TALIAFERRO ROAD IN THE
5TH VOTING DISTRICT (1-2026-409).
Area 1.40 acres
Zoning Rural Development-5 (RD-5)
Lots 1
Water Nolensville/College Grove Utility District
Sewer Individual On-Site Septic System
Development Option Family Subdivision
Chapter 1101 Status Rural
Map and Parcel 140---01413
File Number (1-2026-409)
At this time, the applicant is requesting deferral to the June 2026 Planning Commission
Meeting in order to allow the applicant more time to address Staff comments. Staff
concurs with this request.
Item 33—Page 1 of 1
Reviewer: JYJ
Date: 5/14/2026
ITEM 33
FINAL PLAT REVIEW FOR LOT 201 OF ARTESIAN ACRES SUBDIVISION,
CONTAINING 1 LOT ON 5 ACRES LOCATED OFF ARTESIAN DRIVE IN THE 5TH
VOTING DISTRICT (1-2026-405).
Attachment 33-1 Final Plat
33-2 Aerial Photograph
Area 5 acres
Zoning Municipal Growth Area–1 (MGA-1)
Lots 1
Water Nolensville College Grove Utility District
Sewer Individual On-site Septic System
Development Options Rural
Map and Parcel 59—091.10
File Number (1-2026-405)
A Preliminary Plat for this lot was approved at the March 2026 meeting. The applicant is
now requesting Final Plat approval of Section 2, which contains one (1) lot. Sewer service
will be provided by an on-site septic system. All required infrastructure has been installed,
and therefore no performance bonds are required.
The plat is consistent in l ayout with that depicted on the Preliminary Plat, and therefore
Staff recommends approval of the Final Plat with the condition the applicant provide two
(2) copies of the approved Final Plat in .dwg format on recordable media based on the
Tennessee State Plane Coordinate System prior to signature and recording of the Final
Plat.
MB
14" CULVERT
KENNETH E. MOORE
MARY BETH MOORE
2013 ARTESIAN DR.
DEED BOOK 694, PAGE 688 R.O.W.C.
PLAT BOOK 10, PAGE 165 R.O.W.C.
MAP 59 PARCEL 91.09
S78° 20' 52"W
919.79'
N77° 15' 43"E
1001.39'
C1
JUDY HILL
DANNIE HILL
2019 ARTESIAN DR.
DEED BOOK 5487, PAGE 323 R.O.W.C.
PLAT BOOK 12, PAGE 9 R.O.W.C.
MAP 59 PARCEL 91.11
CONCRETE DRIVE
1/2" IP SET
SSDS AREA (A)
5,014 SQ FT
60MPI MLPP
5-15%
SSDS AREA (B)
5,064 SQ FT
60MPI MLPP
5-15%
INTERCEPTOR DRAIN
SSDS SETBACK
A
C
D
(E2)
(E3)
(D3)
DIRT ROAD
DIRT ROAD
LOT 201
5.00 ± ACRES
(217, 666 ± SQ FT)
ARTESIAN DRIVE (PRIVATE 50' WIDTH)
S22° 00' 05"W
232.64'
MAILBOX
N07° 58' 16"E
231.90'
100 FT M.B.S.L.
20 FT M.B.S.L.
20 FT M.B.S.L.
FOUND 1/2" IP
FOUND 1/2" IP
FOUND 1/2" IP
FOUND 1/2" IP
(D4)
(F2)B
DRAINAGEEASEMENT
v
vvv
v
1
15'
25'
20'
(C3)
(B3)
15'
20'
DRAINAGEEASEMENT
DRAINAGEEASEMENT
25.00'
25.00'
25.00'
E
F
G
20.9'
LOT D
707.0' 705.1'
704.5' 707.1'
CURTAIN DRAIN ELEVATION TABLE
OUTLET 704.1'
MIN. DEPTH
1 36"
GND. ELV.
INV. ELV.
A B C
710.0' 708.1'
E
705.5'
702.5'
F
701.4'
OUTLET
G
706.3'
703.3'
KEYNOTES:
1
ISOLATED ROCK (5' SETBACK REQUIRED)
OLD FENCE ROW/TERRACE MAY BE DISKED, SMOOTHED, AND
INSTALLED THROUGH UNDER W.C.D.S.D.M. SUPERVISION.
v
SITE
EXISTING WATER MAIN
EXISTING OVERHEAD ELECTRICAL
EXISTING MAILBOXMB
IRON PIPE / PIN FOUND
RIGHT-OF-WAY
25' DRAINAGE EASEMENT
DIRT ROAD
ASPHALT PAVEMENT
CAPPED REBAR SET
RIGHT-OF-WAYR.O.W.
MINIMUM BUILDING SETBACK LINEM.B.S.L.
PLAT BOOKPB.
DEED BOOKDB.
PAGEPG.
RECORD DIMENSION( )
LEGEND
BOUNDARY LINE
CONCRETE PAVEMENT
EXISTING CULVERT
M.B.S.L.
OLD FENCE ROW
SECTION 2 FINAL PLAT
E
ROYEVRUSDNALDERETSI
GER
RELHAHPESOJ
TENNESSEE NO. 143
.
4
DEPARTMENT OF SEWAGE DISPOSAL MANAGEMENT NOTES
THE AREA FOR SUBSURFACE SEWAGE DISPOSAL SYSTEM IS SHOWN THUS:
1. LOT 201 IS RESTRICTED TO ONE, (4) BEDROOM, SINGLE FAMILY DWELLING.
2. DESIGNATED SEWAGE DISPOSAL AREAS SHOWN ON THIS PLAT PLOTTED IN ACCORDANCE WITH ACCEPTABLE SOIL AREAS FIELD MAPPED BY J. MICHAEL
HAARBAUER, PRIVATE CONSULTING SOIL CONSULTANT, ON 6/18/24 AND REVISED 07/12/2024.
3. ANY CUTTING, FILLING, COMPACTION OF THE SOILS FROM THEIR NATURAL STATE, OF THE SOIL AREAS RESERVED FOR SEWAGE DISPOSAL, SHALL RESULT IN
REVOCATION OF THE LOT APPROVAL. ADDITIONALLY, THE DEPARTMENT SHALL HAVE AUTHORITY TO REFUSE TO GRANT A CONSTRUCTION PERMIT OR MAY REVOKE A
CONSTRUCTION PERMIT WHERE THE INTEGRITY OF THE PROPOSED SUBSURFACE SEWAGE DISPOSAL SYSTEM AREAS HAVE BEEN COMPROMISED.
4. ALL SEPTIC SYSTEMS MUST BE INSTALLED BY AN INSTALLER LICENSED BY WILLIAMSON COUNTY TO CONSTRUCT ALTERNATIVE OR CONVENTIONAL SEPTIC SYSTEMS.
5. NO UTILITIES (I.E. GAS, WATER, OR ELECTRIC) OR THEIR EASEMENTS, ABOVE OR BELOW GROUND, SHALL BE ALLOWED TO ENCROACH WITHIN 10 FEET OF THE
BOUNDARIES OF THE SOIL AREAS RESERVED FOR SEWAGE DISPOSAL.
6. CURTAIN/INTERCEPTOR/DRAWDOWN DRAINS MAY BE REQUIRED ON ANY OR ALL LOTS. AS SUCH, THEY SHALL ADHERE TO THE DESIGN, LOCATION AND ROUTING
DEPICTED ON THIS PLAT. HOWEVER, THE DRAINS AS SHOWN MAY BE SUBJECT TO CHANGE AT THE SOLE DISCRETION OF THE WILLIAMSON COUNTY DEPARTMENT OF
SEWAGE DISPOSAL MANAGEMENT AS DEEMED NECESSARY BY THEIR FIELD INVESTIGATION AT THE TIME OF SUBMITTAL OF EACH INDIVIDUAL LOTS ALTERNATIVE
SYSTEM SITE AND DESIGN PLANS. THE WILLIAMSON COUNTY DEPARTMENT OF SEWAGE DISPOSAL MANAGEMENT'S EVALUATION WILL BE CONDUCTED ON A
SITE-SPECIFIC, LOT BY LOT BASIS.
7. NO IRRIGATION SYSTEMS, OR THEIR COMPONENTS THEREOF, SHALL ENCROACH ON, IN OR WITHIN 10 FEET OF THE BOUNDARIES OF THE DESIGNATED OR PLATTED
SSDS AREAS. IT SHALL ALSO BE LOCATED A MINIMUM OF 5 FEET AWAY FROM ANY DRAINAGE IMPROVEMENT PRACTICE ASSOCIATED WITH THE SSDS AREA.
8. NO CUTTING, FILLING, OR COMPACTION OR ANY OTHER DISTURBANCE OF THE AREAS RESERVED FOR SEWAGE DISPOSAL SHALL BE PERMITTED.
9. THE LIMITS OF ALL EXCAVATIONS GREATER THAN 18 INCHES IN DEPTH, MADE FOR THE PURPOSE OF HOUSE CONSTRUCTION (OR ANY OTHER TYPE OF BUILDING
CONSTRUCTION), SHALL BE KEPT 25 FEET OR MORE AWAY FROM THE PLATTED OR DESIGNATED SEWAGE DISPOSAL AREAS.
10. THE LIMITS OF ALL EXCAVATIONS, MADE FOR THE PURPOSE OF HOUSE CONSTRUCTION (OR ANY OTHER TYPE OF BUILDING CONSTRUCTION), SHALL BE KEPT WITHIN
THE CONFINES OF THE PLATTED BUILDING ENVELOPE.
11. NO CONSTRUCTION OF PATIOS, SWIMMING POOLS, ACCESSORY BUILDINGS, ETC. SHALL BE ALLOWED ON ANY LOT SERVED BY A SUBSURFACE SEWAGE DISPOSAL
SYSTEM, UNLESS APPROVED BY THE DEPARTMENT OF SEWAGE DISPOSAL MANAGEMENT.
12. WATER SERVICE LINES MUST BE SEPARATED FROM SEWAGE DISPOSAL AREAS OR PLATTED DISPOSAL FIELD AREAS BY A MINIMUM OF 10 FEET.
13. NO WATER SOURCE, WELLS OR SPRINGS ARE TO BE DRILLED OR CONSTRUCTED OR WITHIN 50 FEET OF ANY PORTION OR COMPONENT OF THE SEPTIC SYSTEM OR
THE DESIGNATED OR PLATTED SEWAGE DISPOSAL FIELD AREAS. THIS INCLUDES THE SEPTIC TANK, TIGHTLINES, ALTERNATING VALVES, OR THE DESIGNATED OR
PLATTED SEWAGE DISPOSAL FIELD AREAS.
14. ALL PLATTED SEWAGE DISPOSAL AREAS SHALL BE FIELD STAKED BY A LICENSED SURVEYOR AND FENCED OFF, TO PROTECT THE AREAS FROM ALL CONSTRUCTION
TRAFFIC, BY THE PROPERTY OWNER OR BUILDING CONTRACTOR. THE AREAS THEN SHALL BE FIELD CHECKED AND VERIFIED BY THE DEPARTMENT OF SEWAGE
DISPOSAL MANAGEMENT PRIOR TO THE ISSUANCE OF THE SEPTIC PERMIT.
15. THE EXACT LOCATION OF THE WATER SOURCE (I.E. WELL, CISTERN, SPRING OR PRIVATE WATER SOURCE) MUST BE FIELD LOCATED BY A SURVEYOR OR ENGINEER ON
A COPY OF THIS PLAT AND SUBMITTED TO THE DEPARTMENT OF WILLIAMSON COUNTY DISPOSAL MANAGEMENT FOR REVIEW AND RECORD KEEPING PURPOSES.
16. PRIOR TO INSTALLATION, THE LOCATION OF THE WELL, SPRING, CISTERN OR PRIVATE WATER SOURCE MUST BE APPROVED BY THE WILLIAMSON COUNTY
DEPARTMENT OF SEWAGE DISPOSAL MANAGEMENT.
17. LOCATION OF WELL, SPRING, CISTERN OR PRIVATE WATER SOURCE MUST BE A MINIMUM OF 50 FEET AWAY FROM ANY SEWAGE DISPOSAL AREA, INCLUDING THOSE
LOCATED UPON ADJACENT LOTS.
18. THERE SHALL BE NO SEWAGE CONVEYANCES (PIPES, SUPPLY LINES, MANIFOLDS, SEPTIC OR PUMP TANKS, ETC.) LOCATED WITHIN 50 FEET OF ALL WELL(S) ON THIS
PROPERTY.
19. SSDS COMPONENTS CROSSING UTILITIES AND THEIR RELATED EASEMENTS, IN ADDITION TO DRIVEWAYS, ACCESS EASEMENTS. ETC: ANY AND ALL SSDS
COMPONENTS (INCLUDING BUT NOT LIMITED TO: CURTAIN DRAINS, SEWAGE SUPPLY LINES, MANIFOLDS, ETC.) SHALL BE SHEATHED AND BEDDED (AS PER
SPECIFICATIONS FROM WCDSM) WHERE THEY CROSS ANY DRIVEWAY, ACCESS EASEMENT, UTILITY LINES (AND THEIR RELATED EASEMENTS). THE SHEATHING SHALL
EXTEND FROM A POINT 10 FEET PRIOR TO ENTERING ANY EASEMENT AND SHALL EXTEND THROUGHOUT THE ENTIRE WIDTH OF THE EASEMENT AND SHALL END AT A
POINT 10 FEET PAST THE LIMITS OF ANY EASEMENT. ALL CROSSINGS MUST BE IN ACCORDANCE WITH THE REQUIREMENTS OF THE WILLIAMSON COUNTY
DEPARTMENT OF SEWAGE DISPOSAL MANAGEMENT. ALL SHEATHING MUST BE SCHEDULE 80 PVC OR DUCTILE IRON AND BE BEDDED IN 12" OF GRAVEL.
20. CS DENOTES THAT THIS LOT IS SERVED BY A CONVENTIONAL MEANS OF SUBSURFACE SEWAGE DISPOSAL SYSTEM; LPP DENOTES THAT THIS LOT IS SERVED BY A
LOW PRESSURE PIPE SYSTEM, WHICH IS AN ALTERNATIVE MEANS OF SEWAGE DISPOSAL; MLPP DENOTES THAT THIS LOT IS SERVED BY A MODIFIED LOW PRESSURE
PIPE SYSTEM, WHICH REQUIRES 6 TO 10 INCHES OF COMPATIBLE SOIL FILL MATERIAL TO BE INCORPORATED ONTO THE DESIGNATED OR PLATTED SEWAGE
DISPOSAL AREA UNDER DEPARTMENT OF SEWAGE DISPOSAL MANAGEMENT SUPERVISION.
21. BEFORE A PERMIT TO CONSTRUCT A CONVENTIONAL SYSTEM SERVING SINGLE SOURCE WITH A PROJECTED WASTEWATER FLOW RATE EXCEEDING 750 GALLONS
PER DAY (gpd), DETAILED SITE AND DESIGN PLANS FOR SAID SYSTEM SHALL BE SUBMITTED TO THE DEPARTMENT OF SEWAGE DISPOSAL MANAGEMENT FOR REVIEW
AND APPROVAL. THESE PLANS SHALL BE PREPARED BY AN ENGINEER LICENSED IN THE STATE OF TENNESSEE.
22. BEFORE A PERMIT TO CONSTRUCT A LPP OR MLPP SEPTIC SYSTEM CAN BE ISSUED, DETAILED SITE AND DESIGN PLANS FOR THE LPP OR MLPP SYSTEM SHALL BE
SUBMITTED TO THE DEPARTMENT OF SEWAGE DISPOSAL MANAGEMENT FOR REVIEW AND APPROVAL. THESE PLANS SHALL BE PREPARED BY AN ENGINEER
LICENSED IN THE STATE OF TENNESSEE.
23. AN ARAP PERMIT MUST BE OBTAINED FROM THE STATE OF TENNESSEE AT THE DEPARTMENT OF ENVIRONMENT AND CONSERVATION BEFORE ANY CONSTRUCTION,
EXCAVATION, CLEARING OR GRADING ACTIVITIES CAN OCCUR WITHIN THE CREEK OR WATERWAY NATURAL AREA.
24. (T.C.A. 0400-45-09-.17) GEOTHERMAL WELL CONSTRUCTION STANDARDS FOR CLOSED LOOP GEOTHERMAL BOREHOLES;
SOURCE OF STRUCTURE MINIMUM DISTANCES
SEWER LINE 10'
SEPTIC TANK 25'
SPRINGS 100'
SEPTIC DRAIN FIELDS 25'
WATER WELLS 100'
HOUSE TO SEPTIC TANK CONNECTION 10'
HOUSE TO SEWER CONNECTION 10'
25. ALL PLUMBING FIXTURES TO BE OF THE WATER CONSERVATIVE TYPE, INCLUDING LOW VOLUME FLUSH TOILETS (1.6 GALLONS OR LESS), 1.5 T0 2.0 GALLONS PER
MINUTE SHOWER HEADS, AND FAUCET AERATORS.
26. THE LIMITS OF ALL EXCAVATIONS GREATER THAN 18 INCHES IN DEPTH, MADE FOR THE PURPOSE OF HOUSE CONSTRUCTION (OR ANY OTHER TYPE OF BUILDING
CONSTRUCTION), SHALL BE KEPT 25 FEET OR MORE AWAY FROM THE PLATTED OR DESIGNATED SEWAGE DISPOSAL AREAS.
27. ALL PARTS OF THE HOUSE AND ANY OF ITS RELATED APPENDAGES (INCLUDING, BUT NOT LIMITED TO DETACHED GARAGES, PORCHES, DECKS, SIDEWALKS,
DRIVEWAYS, PARKING AREAS, UTILITIES, ETC.) SHALL STRICTLY ADHERE TO THE MINIMUM SETBACK REQUIREMENTS FROM THE SUBSURFACE SEWAGE DISPOSAL
SYSTEM AREAS AS OUTLINED IN SECTION 13 OF THE REGULATIONS GOVERNING ON-SITE SEWAGE DISPOSAL MANAGEMENT, ADOPTED MAY 16, 2000, AND EFFECTIVE
OCTOBER 1, 2000.
28. THIS SITE MAY MANDATE THE USE OF A SEWAGE/EFFLUENT PUMP AND APPROPRIATELY SIZED PUMP TANK IN ORDER TO PROVIDE SEWER SERVICES FROM THE
HOUSE TO THE SSDS AREAS. THIS SHALL E SPECIFIED BY THE WILLIAMSON COUNTY DEPARTMENT OF SEWAGE DISPOSAL MANAGEMENT BASED UPON THE FINISHED
ELEVATION OF THE HOUSE PLUMBING STUB-OUT AND THE SSDS AREA.
V1.0
CERTIFICATE OF OWNERSHIP AND DEDICATION
I (WE) HEREBY CERTIFY THAT I AM (WE ARE) THE OWNER(S) OF THE
PROPERTY SHOWN AND DESCRIBED HEREON. AS EVIDENCED IN BOOK
NUMBER 9522, PAGE 680, R.O.W.C., AND THAT I (WE) HEREBY ADOPT
THIS PLAN OF SUBDIVISION WITH MY (OUR) FREE CONSENT, ESTABLISH
THE MINIMUM BUILDING RESTRICTION LINE, AND THAT OFFERS OF
IRREVOCABLE DEDICATION FOR ALL PUBLIC STREETS, UTILITIES AND
OTHER FACILITIES HAVE BEEN FILED AS REQUIRED BY THESE
REGULATIONS.
OWNER #1 SIGNATURE DATE
CERTIFICATE OF ACCURACY
I HEREBY CERTIFY THAT THE PLAN SHOWN AND DESCRIBED HERON IS
TRUE AND CORRECT SURVEY TO THE ACCURACY REQUIRED BY THE
WILLIAMSON COUNTY, TENNESSEE REGIONAL PLANNING COMMISSION
AND THAT THE MONUMENTS HAVE BEEN OR WILL BE PLACED AS
SHOWN HERON, TO THE SPECIFICATIONS OF THE SUBDIVISION
REGULATIONS, AS APPROVED BY THE COUNTY ENGINEER.
DATE REGISTERED LAND SURVEYOR
CERTIFICATION OF GENERAL APPROVAL FOR INSTALLATION OF
SUBSURFACE SEWAGE DISPOSAL SYSTEMS WITH RESTRICTIONS
GENERAL APPROVAL IS HEREBY GRANTED FOR LOTS PROPOSED HERON
AS BEING SUITABLE FOR SUBSURFACE SEWAGE DISPOSAL WITH THE
LISTED AND OR ATTACHED RESTRICTIONS.
BEFORE INITIATION OF CONSTRUCTION, THE LOCATION OF THE HOUSE
OR OTHER STRUCTURE AND PLANS FOR THE SUBSURFACE SEWAGE
DISPOSAL SYSTEM SHALL BE APPROVED BY THE LOCAL HEALTH
AUTHORITY.
DATE DEPT. OF SEWAGE DISPOSAL MANAGEMENT
CERTIFICATE OF APPROVAL FOR RECORDING
I HEREBY CERTIFY THAT THE SUBDIVISION PLAT SHOWN HERON HAS
BEEN FOUND TO COMPLY WITH THE SUBDIVISION REGULATIONS FOR
WILLIAMSON COUNTY, TENNESSEE, WITH THE EXCEPTION OF SUCH
VARIANCES, IF ANY, AS ARE NOTED IN THE MINUTES OF THE PLANNING
COMMISSION AND THAT IT HAS BEEN APPROVED FOR RECORDING IN
THE OFFICE OF THE COUNTY REGISTER
THIS APPROVAL SHALL BE
INVALID IF NOT RECORDED BY:
DATE
DATE SECRETARY, PLANNING COMMISSION
NOTES:
OWNER: HUMMING BIRD INV. LP.
ADDRESS: 2015 ARTESIAN DR.
NOLENSVILLE, TN 37135
WILLIAMSON COUNTY, TENNESSEE
17TH CIVIL DISTRICT
DEED: DEED BOOK 9522, PAGE 680, R.O.W.C.
TAX MAP 059, PARCEL 091.10
TOTAL ACREAGE: 5.00 ± ACRES (217,666 ± SQ FT)
SURVEY DATED: 04-22-2024
BASIS OF BEARING: FOR BOUNDARY AND TOPOGRAPHIC ASPECTS OF THIS SURVEY, RTK GPS POSITIONAL DATA WAS OBSERVED ON 04-22-2024 UTILIZING A CARLSON BRx7
DUAL FREQUENCY RECEIVER. THE GRID COORDINATES OF THE FIXED STATION(S) SHOWN WERE DERIVED USING A VRS NETWORK OF CORS STATIONS REFERENCED TO NAD 83
(2011) (EPOCH 2010), GEOID 12B.
POSITIONAL ACCURACY OF THE GPS VECTORS DOES NOT EXCEED: H 0.04’.
COMBINED GRID FACTOR: 0.99992369 CENTERED ON THE FIXED STATION.
ZONING:
MGA-1, MUNICIPAL GROWTH AREA
SETBACKS:
FRONT - ONE HUNDRED (100) FEET
REAR - SIXTY (60) FEET
SIDE - TWENTY (20) FEET
1. THE PURPOSE OF THIS PLAT IS TO CREATE 1 LOT.
2. PUBLIC WATER SUPPLY AVAILABLE UPON REQUEST TO NOLENSVILLE COLLEGE GROVE UTILITY DISTRICT.
3. PROPERTY IS LOCATED IN AN AREA OF MINIMAL FLOOD HAZARD PER FIRM MAPS FLOOD MAP NO. 47187C0240F DATED 09/29/2006, ZONE 'X', WILLIAMSON COUNTY
UNINCORPORATED AREAS, TN COMMUNITY # 470204.
4. THE SURVEYOR HAS NOT PHYSICALLY LOCATED THE UNDERGROUND UTILITIES. ABOVE GRADE AND UNDERGROUND UTILITIES SHOWN WERE TAKEN FROM VISIBLE
APPURTENANCES AT THE SITE, PUBLIC RECORD AND/OR MAPS PREPARED BY OTHERS. THE SURVEYOR MAKES NO GUARANTEE THAT THE UNDERGROUND UTILITIES SHOWN
COMPROMISE ALL SUCH UTILITIES IN THE AREA, EITHER IN SERVICE OR ABANDONED.
5.
THE SURVEYOR FURTHER DOES NOT WARRANT THAT THE UNDERGROUND UTILITIES SHOWN ARE IN THE EXACT LOCATION INDICATED. THEREFORE, RELIANCE UPON HE
TYPE, SIZE, AND LOCATION OF UTILITIES SHOWN SHOULD BE DONE SO WITH THIS CIRCUMSTANCE CONSIDERED. DETAILED VERIFICATION OF EXISTENCE, LOCATION AND
DEPTH SHOULD ALSO BE MADE PRIOR TO ANY DECISION RELATIVE THERETO IS MADE. AVAILABILITY AND COST OF SERVICE SHOULD BE CONFIRMED WITH THE
APPROPRIATE UTILITY COMPANY.
6.
TENNESSEE REQUIRES, PER THE UNDERGROUND UTILITY DAMAGE PREVENTION ACT THAT ANYONE WHO ENGAGES IN EXCAVATION MUST NOTIFY ALL KNOWN
UNDERGROUND UTILITY OWNERS NO LESS THAN (3) THREE NOR MORE THAN (10) WORKING DAYS PRIOR TO THE DATE OF THEIR INTENT TO EXCAVATE AND ALSO TO
AVOID ANY POSSIBLE HAZARD OR CONFLICT. CONTACT TENNESSEE ONE CALL AT 1-800-351-1111
7. THE SURVEYOR'S LIABILITY FOR THIS DOCUMENT SHALL BE LIMITED TO THE ORIGINAL PURCHASER AND DOES NOT EXTEND TO ANY UNNAMED PERSON OR ENTITIES
WITHOUT AN EXPRESSED RE-CERTIFICATION BY THE SURVEYOR WHOSE SIGNATURE APPEARS ON THIS SEAL.
8.
A TEN (10) FOOT EASEMENT ON EACH SIDE OF ALL REAR LOT LINES, TEN (10) FOOT EASEMENT ON EACH SIDE OF ALL SIDE LOT LINES, AND A TEN (10) FOOT EASEMENT
ALONG AND PARALLEL TO ALL RIGHT OF WAY, FOR DRAINAGE, UTILITY POLES, WIRES, CONDUITS, STORM AND SANITARY SEWERS, GAS, WATER, OR OTHER UTILITIES.
9. IN ACCORDANCE WITH THE FIRE PROTECTION STANDARDS OF ARTICLE 3.05 OF THE WILLIAMSON COUNTY SUBDIVISION REGULATIONS BUILDING ENVELOPES MUST BE
SPACED NO CLOSER THAN 200 FEET APART AND EITHER:
A.) SPRINKLER SYSTEMS SHALL BE PROVIDED IN ALL HABITABLE STRUCTURES; OR,
B.) ACCEPTABLE FIRE APPARATUS ACCESS SHALL BE PROVIDED FOR EACH STRUCTURE, INCLUDING THE FOLLOWING:
B1.) THE MAXIMUM DRIVEWAY GRADE (INCLUDING SHARED DRIVES) TO EACH
STRUCTURE SHALL NOT EXCEED 12 %;
B2.) IF THE LENGTH OF ANY DRIVEWAY (INCLUDING SHARED DRIVES) LEADING TO A HABITABLE STRUCTURE EXCEEDS 1,000 FEET, A TURNAROUND
AREA WITH A RADIUS OF AT LEAST 40 FEET SHALL BE PROVIDED EVERY 1,000 FEET ALONG THE DRIVEWAY FROM THE PUBLIC ROAD TO THE FURTHEST HABITABLE
STRUCTURE FROM THE PUBLIC ROAD;
B3.) THE MINIMUM WIDTH OF THE SHARED DRIVEWAY SHALL BE 16 FEET AND THE MINIMUM WIDTH OF THE INDIVIDUAL DRIVES BETWEEN THE
SHARED DRIVE AND THE HABITABLE STRUCTURES SHALL BE 12 FEET; AND
B4.) A LANDING AREA WITH A GRADE NO GREATER THAN 8 % SHALL BE PROVIDED NO FURTHER THAN 200 FEET FROM ALL HABITABLE STRUCTURES IN ORDER TO
STAGE FIREFIGHTING APPARATUS.
PRIVATE DRIVEWAY NOTATION
THIS IS A PRIVATE DRIVEWAY AND IS NOT A PUBLIC ROAD. WILLIAMSON
COUNTY DOES NOT HAVE RESPONSIBILITY FOR BUILDING OR
MAINTAINING THE PRIVATE DRIVEWAY. THE WILLIAMSON COUNTY
HIGHWAY COMMISSION MAY, AT ITS DISCRETION, AGREE TO ACCEPT
THIS PRIVATE DRIVEWAY AS A PUBLIC ROAD INTO THE COUNTY HIGHWAY
SYSTEM IF ALL PROPERTY OWNERS AGREE TO (1) PETITION THE
HIGHWAY COMMISSION FOR A PUBLIC ROAD AND (2) BUILD OR PAY FOR
UPGRADING THE PRIVATE DRIVEWAY TO COUNTY SPECIFICATIONS IN
EFFECT AT TIME OF REQUEST
COUNTY ENGINEER COUNTY ROAD SUPERINTENDENT
DATE
BY SIGNING BELOW, THE PROPERTY OWNER(S) OF ALL LOTS WITHIN THE BOUNDS OF THIS PLAT
ACKNOWLEDGE AWARENESS OF THE ABOVE PRIVATE DRIVEWAY NOTATION, AND UNDERSTAND
WILLIAMSON COUNTY DOES NOT HAVE RESPONISBILITY FOR BUILDING OR MAINTAINING THE
PRIVATE DRIVEWAY
DATE DEED BOOK & PAGE
OWNER SIGNATURE(S) TAX MAP & PARCEL NUMBER OF LOT
NATURAL RESOURCE PROTECTION NOTES (WATERWAY NATURAL AREA (W.N.A.))
1. ANY WATERWAY NATURAL AREA SHOWN HERON IS SUBJECT TO PROTECTIVE COVENANTS WHICH MAY BE FOUND IN THE LAND
RECORDS AND WHICH RESTRICT DISTURBANCE AND USE OF THESE AREAS.
2. WITHIN THE WATERWAY NATURAL AREA, THERE SHALL BE NO CLEARING, GRADING, CONSTRUCTION, OR DISTURBANCE OF
VEGETATION EXCEPT AS PERMITTED BY THE WILLIAMSON COUNTY ENGINEERING DEPARTMENT.
3. WATERWAY NATURAL AREAS (W.N.A.) EXIST ON ALL INTERMITTENT OR PERENNIAL STREAM WATERWAYS AS DEFINED IN THE
WILLIAMSON COUNTY STORM WATER MANAGEMENT REGULATIONS. FOR MORE INFORMATION OR ASSISTANCE IN APPLYING
THESE REGULATIONS, PLEASE CONTACT THE WILLIAMSON COUNTY ENGINEERING DEPARTMENT AT (615)790-5725.
NATURAL RESOURCE PROTECTION NOTES
1. STEEP SLOPES: THIS SITE HAS BEEN REVIEWED FOR THE PRESENCE OF A PROTECTED RESOURCE CONSISTING OF MODERATE STEEP SLOPES (15%-25%) AND VERY STEEP
SLOPES (EXCESS OF 25%). BASED ON THE TENNESSEE LIDAR MAPPING ONE-FOOT CONTOURS, THERE IS EVIDENCE OF MODERATE STEEP SLOPES ON LOT 201. THERE ARE
NO MODERATE STEEP SLOPES WITHIN THE BUILDING ENVELOPE OF LOT 201. THERE ARE NO VERY STEEP SLOPES INSIDE THE BUILDING ENVELOPE OF LOT 201.
2. SLIPPAGE SOILS: THIS SITE HAS BEEN REVIEWED FOR THE PRESENCE OF THE PROTECTED RESOURCE CONSISTING OF SLIPPAGE SOILS FOR LOT 201. THERE ARE NO
EVIDENCE OF SLIPPAGE SOILS BASED ON THE WILLIAMSON COUNTY SOIL SURVEY.
3. KARSTS FEATURES: THIS SITE HAS BEEN REVIEWED FOR THE PRESENCE OF THE PROTECTED RESOURCE CONSISTING OF KARSTS FEATURES FOR LOT 201. THERE IS NO
APPARENT EVIDENCE OF KARSTS TOPOGRAPHY WITHIN OR OUTSIDE THE BUILDING ENVELOPE. BASED ON APPLICANT'S VISUAL RECONNAISSANCE, LOT 201 IS ABSENT OF
KARSTS FEATURES.
4. HILLTOPS AND RIDGE TOPS: THIS SITE HAS BEEN REVIEWED FOR THE PRESENCE OF THE PROTECTED RESOURCE CONSISTING OF HILLTOPS AND RIDGE TOPS FOR LOT 201.
THERE ARE NO HILLTOPS OR RIDGETOPS WITHIN OR OUTSIDE THE BUILDING ENVELOPE. LOT 201 IS ABSENT OF HILLTOPS AND RIDGE TOPS.
5. WETLANDS: THIS SITE HAS BEEN REVIEWED FOR THE PRESENCE OF THE PROTECTED RESOURCE CONSISTING OF WETLANDS AS DETERMINED ON THE NATIONAL WETLANDS
INVENTORY MAPPER OF THE U.S. FISH AND WILDLIFE SERVICE FOR LOT 201. LOT 201 IS ABSENT OF WETLANDS.
6. LAND DISTURBANCE: NO LAND DISTURBING ACTIVITIES IN AREAS GREATER THAN 50% SLOPES. WHERE DRIVEWAYS AND/OR MINOR UTILITIES CROSS VERY STEP SLOPES
BETWEEN 25% & 50%, THE APPLICANT MUST SUBMIT A GEOTECHNICAL STUDY WITH FINDINGS SHOWING THAT DRIVEWAYS AND MINOR UTILITIES WILL NOT HAVE
SIGNIFICANT VISUAL, ENVIRONMENTAL, OR SAFETY IMPACTS, OR APPROPRIATE ENGINEERING OR OTHER MEASURES WILL BE TAKEN BY THE DEVELOPER TO SUBSTANTIALLY
MITIGATE ANY SUCH IMPACT AND IF NO ALTERNATIVE LOCATION FOR ACCESS OR MINOR UTILITIES IS FEASIBLE OR AVAILABLE.
OWNER #2 SIGNATURE DATE
SECTION 2 FINAL PLAT OF THE
ARTESIAN ACRES SUBDIVISION
JOHN BATEY
2015 ARTESIAN DRIVE
WILLIAMSON COUNTY, TENNESSEE
DESIGN
PLANNING
SURVEYING
CIVIL
A
CONSULTING ENGINEERS & LAND SURVEYORS
SPRING HILL, TN 37174
Fax: 615.523.1517
PH 615.481.3106
P.O. BOX 1636
Ahler & Associates, LLC
Sheet No.
Drawn By: Checked By:
Proj. No.:
File Name:
Date:
Date
Sheet.dwg
No. Revision Description
Sheet Title
1234567891011
A
B
C
D
E
F
G
H
I
1208 HIGHWAY 47E DICKSON, TN 37055
(615) 740-8777 (T) (615) 441-8776 (F)
Southern Consulting
Engineering Materials Testing Surveying
Environmental Services
4/21/2026
JHH JEA
4/21/26
ATTACHMENT 33-1
ATTACHMENT 33-2
Item 34—Page 1 of 1
Reviewer: OCW
Date: 5/14/2026
ITEM 34
FINAL PLAT REVIEW FOR KING’S CHAPEL SUBDIVISION, SECTION 16,
CONTAINING 1 LOT ON 0.78 ACRES LOCATED OFF MURFREESBORO ROAD IN
THE 5TH VOTING DISTRICT (1-2026-406).
Attachment 34-1 Preliminary Plat
34-2 Aerial Photograph
Area 0.78 acres
Lots 1
Zoning Rural Development–1 (RD-1)
Water Milcrofton Utility District
Sewer Superior Wastewater System
Development Option Planned Resource Conservation Development (PRCD)
Chapter 1101 Status Rural
File Number (1-2026-406)
A Preliminary Plat for this Section was approved at the November, 2024 meeting. The
applicant is now requesting Final Plat approval for the sixteenth (16 th) Section of the
development, which consists of one buildable lot and appro ximately half an acre (0.5) of
Open S pace. As the Section is internal and infrastructure has been installed , no
Landscaping Plan, Performance bond for water improvement, or a Performance Bond for
roads, drainage, and erosion control are required.
The Final Plat is consistent in layout with that depicted on the Preliminary Plat . Staff
recommends approval of the Final Plat with the following conditions:
1. The approved HOA documents shall addre ss the requirements of Section 17.11:
Gated Subdivisions and Section 17.12: Private Streets of the Zoning Ordinance .
The approved HOA documents must be recorded concurrently with the recording
of the Final Plat.
2. Per the recommendation of the County’s Wastewater Consultant, establishment of
a Performance Bond for the Wastewater Collecti on System in the amount of
$8,000;
3. Execution of performance agreements for the above referenced sureties; and
4. Submission of the approved Final Plat in .dwg format on recordable media based
on the Tennessee State Plane Coordinate System prior to signature and recording
of the plat.
Community
KINGS’ CHAPEL
Owner / Developer:
P.O. BOX 190
ASHBY COMMUNITIES HPH LLC
ARRINGTON, TN 37014
MAP 109- PARCEL 40.00 BOOK 9384, PG. 881
06
91
.SSE
ET
NN
NEE O
PO Box 1012
Smyrna, TN 37167-1012
(615) 347-5918
pjernigan@hfrsurvey.com
(615) 519-3935
dreagan@hfrsurvey.com
ALL MILCROFTON UTILITY DISTRICT (MUD) EASEMENTS ARE EXCLUSIVE EASEMENTS. NO EXCAVATION, BUILDING, STRUCTURE, OR OBSTRUCTION OF ANY KIND
MAY BE CONSTRUCTED OR PERMITTED WITHIN THE EASEMENTS, EXCEPT PAVEMENT FOR A DRIVEWAY THAT CROSSES AN EASEMENT. NO TREES OR SHRUBBERY
MAY BE PLANTED WITHIN THE EASEMENTS. MUD WILL HAVE UNRESTRICTED ACCESS TO ALL OF ITS LINES, METERS, VALVES, VAULTS, AND OTHER WATER SYSTEM
FACILITIES WITHIN THE EASEMENTS WITHOUT SEEKING ANY FURTHER PERMISSION. EARTHEN COVER, FILL, OR FINISHED GRADE ABOVE THE TOP OF THE PIPELINE
SHALL BE NO LESS THAN 36" AND NO MORE THAN 48". ALL SLOPES, WHETHER CUT OR FILLED WITHIN THE EASEMENT AREA SHALL HAVE A MAXIMUM SLOPE OF 5
HORIZONTAL TO 1 VERTICAL (5:1) AND SHALL NOT EXCEED THIS GRADE. MUD HAS THE RIGHT TO DISTURB OR REMOVE ANY IMPERMISSIBLE ITEMS WITHIN THE
EASEMENTS. THE PROPERTY OWNER WILL BE RESPONSIBLE FOR REPAIRING OR REPLACING ANY SUCH ITEMS AT THE PROPERTY OWNER'S EXPENSE.
MILCROFTON UTILITY DISTRICT IS REQUIRED TO PROVIDE A MINIMUM OF 20 PSI AT METER PER TDEC REGULATIONS. DUE TO HIGHER ELEVATIONS, BUILDER MAY
ELECT TO INSTALL BOOSTER PUMPS ON INDIVIDUAL HOMES TO IMPROVE DOMESTIC WATER PRESSURE.
ALL PROPERTIES AND IMPROVEMENTS SHOWN ON THIS PLAT SHALL BE SUBJECT TO AND COMPLY WITH THE RULES AND REGULATIONS OF MILCROFTON UTILITY
DISTRICT, AS AMENDED FROM TIME TO TIME. COMPLIANCE INCLUDES, BUT IS NOT LIMITED TO, REQUIREMENTS REGARDING SEPARATE WATER SERVICE
CONNECTIONS FOR IRRIGATION SYSTEMS AND FIRE PROTECTION SYSTEMS. THE RULES AND REGULATIONS INCORPORATE BY REFERENCE ALL APPLICABLE
TECHNICAL SPECIFICATIONS. NON-COMPLIANCE MAY RESULT IN DENIAL OR DISCONTINUATION OF WATER SERVICE BY MILCROFTON UTILITY DISTRICT.
Contact
Natalia Powell
Ashby Communities, LLC.
P.O. Box 190 Arrington, TN 37014
(615) 395-0047
SITE ADDRESS:
Murfreesboro Road
Arrington, TN 37014
ATTACHMENT 34-1
ATTACHMENT 34-2
Item 35—Page 1 of 1
Reviewer: OCW
Date: 5/14/2026
ITEM 35
FINAL PLAT REVIEW FOR HIGH PARK HILL SUBDI VISION, SECTION 5,
CONTAINING 40 LOTS ON 59.86 ACRES LOCATED OFF MURFREESBORO ROAD
IN THE 5TH VOTING DISTRICT (1-2026-407).
Area 59.86 acres
Zoning Rural Development-5 (RD-5)
Lots 40 lots
Water Milcrofton Utility District
Sewer Nontraditional Wastewater Treatment and Disposal System
Development Options Conservation Subdivision
File Number (1-2026-407)
At this time, the applicant is requesting deferral to the June 2026 Planning Commission
Meeting in order to allow the applicant more time to address Staff comments. Staff
concurs with this request.
Item 36—Page 1 of 1
Reviewer: OCW
Date: 5/14/2026
ITEM 36
FINAL PLAT REVIEW FOR ARBORS OF LEIPERS FORK SUBDIVISION, SECTION
2, CONTAINING 16 LOTS ON 133 ACRES LOCATED OFF HARGROVE ROAD IN
THE 1ST VOTING DISTRICT (1-2026-408).
Attachment 36-1 Final Plat
36-2 Aerial Photograph
Area 133 acres
Lots 16
Zoning Rural Preservation–5 (RP-5)
Water HB&TS Utility District
Sewer Individual On-Site Septic Systems
Development Option Traditional Subdivision
Chapter 1101 Status Rural
File Number (1-2026-408)
A Preliminary Plat for this Section of the development was approved by this body at the
March 2026 meeting. The applicant is now requesting Final Plat approval for this Section
of the development, which contains sixteen (16) lots and 61.72 acres of Open Space. The
roads within the development will be private and the development will be gated. As the
section is internal no bonds required.
The Final Plat is consistent in layout with the approved Preliminary Plat, and Staff
recommends approval of the Final Plat with the following conditions:
1. The HOA documents shall address the requirements of Section 17.11: Gated
Subdivisions and Section 17.12: Private Streets of the Zoning Ordinance . The
approved HOA documents must be recorded concurrently with the recording of
the Final Plat.
2. Execution of Performance Agreements for the above referenced sureties;
3. Execution of a Stormwater Maintenance Agreement and submission of an
Operation and Maintenance Plan for stormwater improvements; and
4. Providing two (2) copies of the approved Final Plat in .dwg format on recordable
media based on the Tennessee State Plane Coordinate System prior to signature
and recording of the Final Plat.
15'
17'
20' ACCESS EASEMENT
COVER SHEET
1 OF 7
HARGROVE ROAD
P/O MAP 94, PARCEL 38.07
FOR
THE ARBORS AT LEIPERS FORK SECTION 2
Franklin, Williamson County, Tennessee
FINAL PLAT
N.T.S.
LOCATION MAP
DEVELOPER: BABY C.E. Crews Jr./BABY CC Trust
555 GREAT CIRCLE ROAD
NASHVILLE, TN 37228
ENGINEER: T-SQUARE ENGINEERING
111 SOUTHEAST PARKWAY CT
FRANKLIN, TN 37064
WATER UTILITY: HB&TS
505 DOWNS BLVD.
FRANKLIN, TN 37064
SURVEYOR: T-SQUARE ENGINEERING
111 SOUTHEAST PARKWAY CT
FRANKLIN, TN 37064 SITE
APPLICANT
T-SQUARE ENGINEERING
111 SE PARKWAY CT
FRANKLIN, TN 37064
615.678.8212
FLOOD NOTE
NO PORTION OF THIS PROPERTY IS LOCATED IN AN AREA DESIGNATED AS A 100 YEAR FLOOD ZONE
AS EVIDENCED ON FEMA PANEL # 47187C0165F OF WILLIAMSON COUNTY, TN, DATED 09/29/2006 AND
FEMA PANEL # 47187C0170F OF WILLIAMSON COUNTY, TN, DATED 09/29/2006.
DATE
T-SQUARE
drawn by:
AS SHOWN
scale:
03/30/2026
date: NO. REVISIONS
khm
reviewer:
SrRMect
21-0831
sheet
THE ARBORS AT LEIPERS FORK -
SECTION 2
HARGROVE RD, FRANKLIN, TN 37064
MAP 94, P/O PARCEL 38.07
WILLIAMSON COUNTY, TENNESSEE
T-SQUAREENGINEERING
OWNER OF RECORD
BABY CE CREWS JR/BABY CC TRUST
555 GREAT CIRCLE ROAD, NASHVILLE, TN 37228
TAX MAP 94, P/O PARCEL 38.00
DEED BOOK 9543, PAGE 538
1 04/15/26 REVISIONS PER STAFF COMMENTS
2 04/29/26 REVISIONS PER STAFF COMMENTS
Sheet Schedule
1 Cover Sheet
2 Notes and Tables
3 Sheet Key
4-6 Final Plat
7 Overall Plan
CERTIFICATE OF OWNERSHIP AND DEDICATION
I (WE) HEREBY CERTIFY THAT I AM (WE ARE) THE OWNER(S) OF THE PROPERTY SHOWN
AND DESCRIBED HEREON AS EVIDENCED IN BOOK 9543, PAGE 573, R.O.W.C., AND THAT I
(WE) HEREBY ADOPT THIS PLAN OF SUBDIVISION WITH MY (OUR) FREE CONSENT,
ESTABLISH THE MINIMUM BUILDING RESTRICTION LINE, AND THAT OFFERS OF
IRREVOCABLE DEDICATION FOR ALL PUBLIC STREETS, UTILITIES AND OTHER FACILITIES
HAVE BEEN FILED AS REQUIRED BY THESE REGULATIONS.
__________ ___________, 20____ __________________________________
DATE CHARLES CREWS
__________ __________________ __________________________________
OWNER NAME (PRINTED) TITLE (IF ACTING FOR PARTNERSHIP
BABY CC TRUST OR CORPORATION)
CERTIFICATE OF SURVEY ACCURACY
I HEREBY CERTIFY THAT THE PLAN SHOWN AND DESCRIBED HEREON IS A TRUE AND
CORRECT SURVEY TO THE ACCURACY REQUIRED BY THE WILLIAMSON COUNTY,
TENNESSEE REGIONAL PLANNING COMMISSION AND THAT THE MONUMENTS HAVE BEEN
OR WILL BE PLACED AS SHOWN HEREON, TO THE SPECIFICATIONS OF THE SUBDIVISION
REGULATIONS, AS APPROVED BY THE COUNTY ENGINEER.
__________, 20____ ___________________________________
DATE SAM BILLINGSLEY, R.L.S.
CERTIFICATE OF APPROVAL OF SUBDIVISION NAME & STREET NAMES
I DO HEREBY CERTIFY THAT THE SUBDIVISION NAME AND STREET NAMES DENOTED ON
THIS FINAL PLAT HAVE BEEN APPROVED BY THE WILLIAMSON COUNTY EMERGENCY
MANAGEMENT AGENCY (EMA).
__________, 20____ ___________________________________ ____________
DATE EMA DEPARTMENT TITLE/DEPT.
OR AUTHORIZED IT REPRESENTATIVE
CERTIFICATE OF ADDRESSES
I DO HEREBY CERTIFY THAT THE ADDRESSES DENOTED ON THIS FINAL PLAT ARE THOSE
ASSIGNED BY THE DEPARTMENT OF INFORMATION TECHNOLOGY (IT).
__________, 20____ __________________________________________
DATE IT DEPARTMENT
CERTIFICATE OF APPROVAL OF WATER SYSTEMS
I HEREBY CERTIFY THAT THE FOLLOWING UTILITY SYSTEMS OUTLINED OR INDICATED ON
THE FINAL SUBDIVISION PLAT ENTITLED "THE ARBORS AT LEIPERS FORK PHASE 1, FINAL
PLAT" HAVE BEEN INSTALLED IN ACCORDANCE WITH CURRENT LOCAL AND/OR STATE
GOVERNMENT REQUIREMENTS OR THAT A SURETY BOND HAS BEEN POSTED WITH THE
PLANNING COMMISSION TO ASSURE COMPLETION OF ALL REQUIRED IMPROVEMENTS IN
CASE OF DEFAULT. ADDITIONALLY, I CERTIFY THAT THE HYDRAULIC DESIGN CRITERIA
SPECIFIED IN SECTION 5.5 OF THE WILLIAMSON COUNTY SUBDIVISION REGULATIONS
HAVE BEEN MET.
__________, 20____ ______________________________________________
DATE HB & TS UTILITY DISTRICT
CERTIFICATE OF APPROVAL FOR RECORDING
I HEREBY CERTIFY THAT THE SUBDIVISION PLAT SHOWN HEREON HAS BEEN FOUND TO
COMPLY WITH THE SUBDIVISION REGULATIONS FOR WILLIAMSON COUNTY, TENNESSEE,
WITH THE EXCEPTION OF SUCH VARIANCES, IF ANY, AS ARE NOTED IN THE MINUTES OF
THE PLANNING COMMISSION, AND THAT IT HAS BEEN APPROVED FOR THE RECORDING IN
THE OFFICE OF THE COUNTY REGISTER.
__________, 20____ __________________________________________
DATE SECRETARY, PLANNING COMMISSION
THIS APPROVAL SHALL BE INVALID IF NOT RECORDED BY _____________
DATE
04-29 26
CERTIFICATE OF GENERAL APPROVAL FOR INSTALLATION OF
SUBSURFACE SEWAGE DISPOSAL SYSTEM WITH RESTRICTIONS
GENERAL APPROVAL IS HEREBY GRANTED FOR LOTS PROPOSED HEREON AS BEING
SUITABLE FOR SUBSURFACE SEWAGE DISPOSAL WITH THE LISTED AND/OR ATTACHED
RESTRICTIONS.
BEFORE THE INITIATION OF CONSTRUCTION, THE LOCATION OF THE HOUSE OR OTHER
STRUCTURE AND PLANS FOR THE SUBSURFACE SEWAGE DISPOSAL SYSTEM SHALL BE
APPROVED BY THE LOCAL HEALTH AUTHORITY.
__________,20_____ ________________________________________________
DATE DEPT. OF SEWAGE DISPOSAL MGMT., BRIAN CORWIN
CERTIFICATE OF APPROVAL OF STREETS
I HEREBY CERTIFY THAT ALL STREETS DESIGNATED ON THIS FINAL SUBDIVISION PLAT HAVE BEEN
INSTALLED IN AN ACCEPTABLE MANNER AND ACCORDING TO WILLIAMSON COUNTY ROADWAY AND
DRAINAGE REGULATIONS OR THAT A SURETY BOND HAS BEEN POSTED WITH THE WILLIAMSON COUNTY
PLANNING COMMISSION TO ASSURE COMPLETION OF ALL STREET IMPROVEMENTS IN CASE OF DEFAULT.
__________, 20____ __________________________________________
DATE COUNTY ENGINEER
__________, 20____ __________________________________________
DATE COUNTY ROAD SUPERINTENDENT
PINEWOOD RD
HARGROVE RD
JACKSON WHITE RDBOY SCOUT RD
ATTACHMENT 36-1A
25-FT
SETBACK
25-FT SETBACK
25-FT SETBACK
25-FTSETBACK
25-FT
SETBACK
25-FT SETBACK
25-FT SETBACK
25-FT SETBACK
25-FT SETBACK
25-FT SETBACK
25-FT SETBACK
25-FT SETBACK
25-FT SETBACK
25-FT SETBACK
25-FT SETBACK
25-FT SETBACK
25-FT SETBACK
25-FT SETBACK
25-FT SETBACK
25-FT SETBACK
25-FT SETBACK
25-FT SETBACK
25-FT SETBACK
25-FT SETBACK
25-FT SETBACK
25-FT SETBACK
25-FT SETBACK
25-FT SETBACK
25-FT SETBACK
25-FT SETBACK
25-FT
SETBACK
25-FTSETBACK
25-FT SETBACK
25-FT SETBACK
25-FT SETBACK
25-FT SETBACK
25-FT SETBACK
25-FT SETBACK
25-FT SETBACK
25-FT SETBACK
25-FT SETBACK
25-FT SETBACK
25-FT SETBACK
25-FT SETBACK
25-FT SETBACK
25-FT SETBACK
25-FT SETBACK
A
B
C
D
E
F
G
A
B
CD
FG
A
B
C
D
E
A
D
E F
B
C
A
B
C
EF
E
C
B
EAD
F
G
A
D
C
E
B
B
E
C
D
AF
F
A
B
B
C
D
E
A
E
F
D
C
A
B
C
E
D D
A
B
C
E
D
C
B
A
E
F
F E
A
B
C
D
A
B
C
D
E
B
C
D
A
E
A
B
C
D
E
F
G
H
A
B
C
D
E
F
G
H
AB
C
D
E
F
G
H
J
A
B
C
D
E
F
G H J
K
L
M
AB
C
D
E
F
G
H
J
A
BC
D
E
F
G
H
A
BCD
E
F
A B C
D
E
F G
H
J
KL
A
B C
D
E
A
B
C
D
E
F
H
2''W
2''W
2''W
2''W
2''W
8''W
8''W
8''W
8''W
8''W
8''W
8''W
8''W
8''W
8''W
8''W
8''W
8''W
HARGROVE ROAD
100' MBSL
100' MBSL
100' MBSL
25' MBSL
50' MBSL
50' MBSL
97' MBSL
55' MBSL
40' MBSL
100' MBSL
70' MBSL
100' MBSL
100' MBSL
50' MBSL
86' MBSL
25' MBSL
92' MBSL
100' MBSL
104' MBSL
100' MBSL
229' MBSL
100' MBSL
100' MBSL
104' MBSL
108' MBSL
245' MBSL
166' MBSL
94' MBSL
245' MBSL
100' MBSL
124' MBSL
50' MBSL
100' MBSL
25' MBSL
186' MBSL
58' MBSL
140' MBSL
65' MBSL
59' MBSL
55' MBSL
216' MBSL
33' MBSL
187' MBSL
108' MBSL
56' MBSL
100 MBSL
146' MBSL
100' MBSL
120' MBSL
78' MBSL
50' MBSL
111' MBSL
63' MBSL
111' MBSL
90' MBSL
148' MBSL
65' MBSL
50' MBSL
100' MBSL
198' MBSL
198' MBSL
124' MBSL
113' MBSL
57' MBSL
FRONT OF PARCEL
4''W
4''W
4''W
*
*
*
*
*
*
*
*
*
*
* *
4''W
4''W
102
207
110
4''W
4''W
4''W
4''W4''W
4''W 4''W
4''W
101
214
OS-101
OS-103
OS-105
OS-106
OS-104
104
103
OS-102
OS-201
201
202
203
204
205
206
208
209
210
211
215
216
213
212
100' MBSL
25' MBSL
25' MBSL
100' MBSL
25' MBSL
78' MBSL
25' MBSL
100' MBSL
100' MBSL
51' MBSL
100'
MBSL
100' MBSL
50' MBSL
25' MBSL
80' MBSL
FRONT OF PARCEL
*
*
*
*
*
*
*
*
*
25' MBSL
100' MBSL
100' MBSL
15'
17'
20' ACCESS EASEMENT
LEGEND
EXISTING MAJOR CONTOURS
EXISTING MINOR CONTOURS
EXISTING PROPERTY BOUNDARY
ADJACENT PROPERTY LINES
WATER NATURAL AREA BUFFER
EXISTING POWER POLE
EXISTING OVERHEAD POWER
EXISTING WATER LINE
EXISTING SANITARY MANHOLE
EXISTING TREE LINE
EXISTING FENCE
LEGEND
EXISTING MAJOR CONTOURS
EXISTING MINOR CONTOURS
EXISTING PROPERTY BOUNDARY
ADJACENT PROPERTY LINES
WATER NATURAL AREA BUFFER
EXISTING POWER POLE
EXISTING OVERHEAD POWER
EXISTING WATER LINE
EXISTING SANITARY MANHOLE
EXISTING TREE LINE
EXISTING FENCE
W
X X X
500
498
OHP
S
7 OF 7
OVERALL PLAN
APPLICANT
T-SQUARE ENGINEERING
111 SE PARKWAY CT
FRANKLIN, TN 37064
615.678.8212
FLOOD NOTE
NO PORTION OF THIS PROPERTY IS LOCATED IN AN AREA DESIGNATED AS A 100 YEAR FLOOD ZONE
AS EVIDENCED ON FEMA PANEL # 47187C0165F OF WILLIAMSON COUNTY, TN, DATED 09/29/2006 AND
FEMA PANEL # 47187C0170F OF WILLIAMSON COUNTY, TN, DATED 09/29/2006.
DATE
T-SQUARE
drawn by:
AS SHOWN
scale:
03/30/2026
date: NO. REVISIONS
khm
reviewer:
SrRMect
21-0831
sheet
THE ARBORS AT LEIPERS FORK -
SECTION 2
HARGROVE RD, FRANKLIN, TN 37064
MAP 94, P/O PARCEL 38.07
WILLIAMSON COUNTY, TENNESSEE
T-SQUAREENGINEERING
OWNER OF RECORD
BABY CE CREWS JR/BABY CC TRUST
555 GREAT CIRCLE ROAD, NASHVILLE, TN 37228
TAX MAP 94, P/O PARCEL 38.00
DEED BOOK 9543, PAGE 538
1 04/15/26 REVISIONS PER STAFF COMMENTS
2 04/29/26 REVISIONS PER STAFF COMMENTS
PROPOSED
GATE
MAILBOX
KIOSK
60' WNA
25'
NATURAL
WALKING
TRAIL (TYP.)
NATURAL
WALKING
TRAIL (TYP.)
NATURAL
WALKING
TRAIL (TYP.)
60' WNA
LAUREL VALLEY
MAYVIEW PASS (PVT)
DRIVE
LAUREL
HARGROVE ROAD
HARGROVE ROAD
50' ROW
50' ROW
20' TRAVEL
LANE
20' TRAVEL LANE
CAROTENE
COURT
VALLEY
DRIVE
LAUREL
VALLEY
DRIVE
20' TRAVEL LANE
50' ROW
(PVT)
- 50-FT ROW
- 50-FT ROW
(PVT)
- 50-FT ROW
(PVT) - 50-FT ROW
(PVT)
- 50-FT ROW
CHARLES & KIMBERLY CREWS
DEED BOOK 5780, PAGE 296
MAP 94, P/O PARCEL 38.00
ZONED RP-5
CHARLES & KIMBERLY CREWS
DEED BOOK 5780, PAGE 296
MAP 94, P/O PARCEL 38.00
ZONED RP-5
HB&TS UTILITY DISTRICT
DEED BOOK 1147, PAGE 820
MAP 94, PARCEL 44.00
ZONED RP-5
ARBORS AT LEIPERS FORK
SUBDIVISION SECTION 1 -
OPEN SPACE OS-102
PLAT BOOK P86, PAGE 132
ARBORS AT LEIPERS FORK
SUBDIVISION SECTION 1 -
OPEN SPACE OS-104
PLAT BOOK P86, PAGE 132
ARBORS AT LEIPERS FORK
SUBDIVISION SECTION 1 -
OPEN SPACE OS-102
PLAT BOOK P86, PAGE 132
ARBORS AT LEIPERS FORK
SUBDIVISION SECTION 1 -
OPEN SPACE OS-102
PLAT BOOK P86, PAGE 132
ARBORS AT
LEIPERS FORK
SUBDIVISION
SECTION 1 -
OPEN SPACE
OS-105
PLAT BOOK P86,
PAGE 132
ARBORS AT
LEIPERS FORK
SUBDIVISION
SECTION 1 -
OPEN SPACE
OS-106
PLAT BOOK P86,
PAGE 132
ARBORS AT LEIPERS FORK
SUBDIVISION SECTION 1 -
LOT 104
PLAT BOOK P86, PAGE 132
ARBORS AT LEIPERS FORK
SUBDIVISION SECTION 1 -
LOT 105
PLAT BOOK P86, PAGE 132
ARBORS AT LEIPERS FORK
SUBDIVISION SECTION 1 -
LOT 110
PLAT BOOK P86, PAGE 132
BABY C E CREWS JR/BABY
CC TRUST
DEED BOOK 9543, PAGE 573
MAP 94, PARCEL 38.07
ZONED RP-5
WILLOW TREE LAND TRUST
DEED BOOK 9648, PAGE 574
MAP 94, PARCEL 38.08
ZONED RP-5
KEVIN & DEBORAH LUNSFORD
DEED BOOK 7537, PAGE 920
MAP 94, PARCEL 38.04
ZONED RP-5
NANCY OSMAN
DEED BOOK 8719, PAGE 77
MAP 94, PARCEL 38.02
ZONED RP-5
NOTE:
1. THIS PROPERTY HAS BEEN REVIEWED FOR THE EXISTENCE OF
INTERMITTENT AND PERENNIAL STREAMS. STREAMS THAT WOULD
REQUIRE WATERWAY NATURAL AREAS AS DESCRIBED IN SECTION 4 OF
THE WILLIAMSON COUNTY STORM WATER MANAGEMENT REGULATIONS
HAVE BEEN LOCATED AS SHOWN.
2. THIS SITE HAS BEEN REVIEWED FOR THE PRESENCE STEEP SLOPES,
HILLTOPS AND RIDGETOPS, SLIPPAGE SOILS, AND KARST FEATURES.
AREAS FALLING WITHIN THESE CATEGORIES WILL BE ADDRESSED PER
THE WILLIAMSON COUNTY ZONING CODE.
3. SEPTIC NOTE: STUMP HOLE - 5FT SETBACK IF BACKFILLED AND
REMEDIATED.
4. THIS SITE HAS BEEN REVIEWED FOR THE PRESENCE OF KARST
FEATURES. NO KARST FEATURES WERE FOUND
5. THIS SITE HAS BEEN REVIEWED FOR THE PRESENCE OF STEEP
SLOPES.
6. WITHIN THE WATERWAY NATURAL AREA, THERE SHALL BE NO
CLEARING, GRADING, CONSTRUCTION OR DISTURBANCE OF
VEGETATION EXCEPT AS PERMITTED BY THE WILLIAMSON COUNTY
ENGINEERING DEPARTMENT.
7. ALL NATURE TRAILS WILL BE MINIMUM 15FT OFF OF THE TOP OF
STREAM BANKS. THE NATURE TRAILS WILL BE PERMEABLE AND WILL BE
FIELD LOCATED PRIOR TO CONSTRUCTION.
8. THE SITE HAS BEEN REVIEWED FOR SPECIAL FLOOD HAZARD AREAS
AND WETLAND AREAS. THE WATERWAY NATURAL AREAS SHOWN ON
THE PLAN ARE TO BE MITIGATED AS NECESSARY.
9. PROJECT IS REQUESTING AN INTERNAL RIGHT-OF-WAY WIDTH OF FIFTY
(50) FEET AND A DESIGN SPEED OF TWENTY-FIVE (25) MPH FOR
INTERNAL ROADWAYS DUE TO THE SITES TOPOGRAPHY AND TO
ENHANCE THE COMMUNITY DEVELOPMENT AND CONSERVE OPEN
SPACE
10. ALL LOTS WITHIN THE SUBDIVISION ARE DEEMED CRITICAL LOTS AND
ARE REQUIRED TO HAVE A CRITICAL LOT SITE PLAN AT BUILDING
PERMIT APPLICATION.
MODIFICATION TO STANDARDS:
1. Due to deficient fire flows from the utility provider, the applicant is requesting a
modification of standards to waive the requirement for fire hydrants to be installed per the
subdivision regulations. At the direction of the Fire Marshal the following conditions shall be met
for this modification:
a. All structures shall be sprinkled with residential fire suppression systems.
b. Structures shall maintain at least 200 ft separation.
c. Cul-de-sacs and intersections shall have adequate turning radii for fire apparatus.
d. R esidential driveways shall be at least 12 ft in width.
2. In efforts to minimize disturbance and better control speed within the community, the
applicant is requesting a modification of standards to minimize pavement widths within The
Arbors at Leiper's Fork. The applicant is requesting a 20 ft pavement width throughout the
subdivision and 16 ft minimum width for one-way sections at the entrance, cul-de-sacs, etc. At
the direction of the Fire Marshal the following conditions shall be met for this modification:
a. All streets including intersections and cul-de-sacs shall have adequate turning radii for
fire apparatus.
b. Residential driveways shall be at least 12 ft in width.
c. Gates shall include emergency access override features.
d. On-street parking shall be discouraged within the development.
T.C.A.0400-45-09-.17
GEOTHERMAL WELL CONSTRUCTION STANDARDS FOR
CLOSED LOOP GEOTHERMAL BOREHOLES
SOURCE OF STRUCTURE MINIMUM DISTANCE
SEWER LINES 10 FEET
SEPTIC TANKS 25 FEET
SPRINGS 100 FEET
SEPTIC DRAIN FIELDS 25 FEET
WATER WELLS 100 FEET
HOUSE TO SEPTIC TO TANK CONNECTION 10 FEET
HOUSE TO SEWER CONNECTION 10 FEET
( IN FEET )
GRAPHIC SCALE
250
SCALE: 1" = 250'
125
AT 24"X36" PLOT
KEY PLAN
N.T.S.
SHEET 4
SHEET 6
SHEET 5
ATTACHMENT 36-1B
ATTACHMENT 36-2
ORDER OF BUSINESS
WILLIAMSON COUNTY REGIONAL PLANNING COMMISSION
1. Call to order
2. Roll Call
3.
Announcements
4.
Public Comments
5.
Consideration of Minutes
6.
Consideration of Consent Agenda
7.
Presentation of Agenda Items for Discussion and Action
8. Other Business
AGENDA
WILLIAMSON COUNTY REGIONAL PLANNING COMMISSION
Williamson County Administrative Complex
May 14, 2026 at 5:30 p.m.
PUBLIC COMMENTS:
Public comment is permitted on Agenda items – sign-in prior to the meeting is required.
MINUTES:
1. Approval of April 9, 2026 Minutes
CONSENT AGENDA:
2. Consent Agenda
BONDS:
3. Arrington Woods, Section 1 – Performance Bond for Landscaping located off
Nolensville Road.
4. Arrington Woods, Section 1 – Performance Bond for Roads, Drainage and Erosion
locate off Nolensville Road.
5. Daventry, Section 1 - Maintenance Bond for Roads, Drainage and Erosion Control
located off Tullous Road.
6. Daventry, Section 3 - Maintenance for Roads, Drainage and Erosion Control located
off Tullous Road.
7. Enclave at Dove Lake, Section 2 – Maintenance Bond for Roads, Drainage and Erosion
Control located off Nolensville Road.
8. Fiddlers Glen/Cox Ladd – Maintenance Bond for Landscaping located off Murfreesboro
Road.
9. Fiddlers Glen, Section 1 – Performance Bond for Roads, Drainage and Erosion Control
located off Murfreesboro Road.
10. Hardeman Springs, Section 1 – Maintenance Band for Roads, Drainage and Erosion
Control located off Murfreesboro Road.
11. Hart’s Landmark – Maintenance Bond for Sewer located off North Chapel Road.
12. High Park Hill Amenity – Performance Bond for Landscaping located off Murfreesboro
Road.
13. High Park Hill Amenity – Performance Bond for Wastewater Collection System located
off Murfreesboro Road.
14. High Park Hill, Section 4 – Performance Bond for Roads, Drainage and Erosion Control
located off Murfreesboro Road.
15. Reeds Vale Amenity – Performance Bond for Landscaping located off Lampkins Bridge
Road.
16. Reeds Vale, Section 1 – Maintenance Bond for Roads, Drainage and Erosion Control
located off Lampkins Bridge Road.
17. Reeds Vale, Section 2 – Performance Bond for Landscaping located off Lampkins
Bridge Road.
18. St. Barbara’s Coptic Church – Maintenance Bond for Landscaping located off
Clovercroft Road.
19. St. Marlo, Section 3 – Maintenance Bond for Wastewater Collection System located
off Long Lane.
20. Taliaferro Subdivision – Performance Bond for Landscaping located off Taliaferro
Road.
21. Taliaferro Subdivision – Performance Bond for Roads, Drainage and Erosion Control
located off Taliaferro Road.
22. Vista Creek – Performance Bond for Landscaping located off Old Hillsboro Road.
OLD BUSINESS:
23. Terravista Roads, Drainage, and Erosion Control Bond Update.
24. Preliminary Plat Review for Lot 1 of the Larry U. Turner Property LLE Subdivision,
containing 1 lot on 20.33 acres located off Carl Road in the 5th Voting District (1 -
2026-301).
25. Concept Plan Review for Wilson Branch Farms Subdivision (AKA 3036 Old
Murfreesboro Road), containing 28 lots on 34.15 acres located off Old Murfreesboro
Road in the 5th Voting District (1-2025-213).
26. Preliminary Plat Review for Chestnut Hill Farms LLE Subdivision, containing 5 lots on
28.5 acres located off Whippoorwill Drive in the 1st Voting District (1 -2025-324).
27. Preliminary Plat Review for Joybelle Estates Subdivis ion, containing 12 lots on 110.1
acres located off Eudailey Covington Road in the 2 nd Voting District (1-2026-304).
28. Preliminary Plat Review for Creekbend Manor LLE Subdivision (AKA 8828 Horton
Highway), containing 5 lots on 28.01 acres located off Horton Highway in the 2 nd
Voting District (1-2025-334).
NON-RESIDENTIAL SITE PLANS:
29. Site Plan Review for Arbors at Leipers Fork Subdivision Amenity Center, on 51.41 acres
located off Hargrove Road in the 1st Voting District (5-2026-002).
PRELIMINARY PLATS:
30. Preliminary Plat Review for Dodd Family Revocable Living Trust Subdivision,
containing 1 lot on 32.12 acres located off Taliaferro Road in the 5th Voting District
(1-2026-305).
31. Preliminary Plat Review for Haley Valley LLE Subdivision, containing 5 lots on 25.12
acres located off Murfreesboro Road in the 5 th Voting District (1-2026-307).
FINAL PLATS:
32. Final Plat Review for Foster Subdivision Family Subdivision, containing 1 lot on 1.40
acres located off of Taliaferro Road in the 5th Voting District (1-2026-409 ).
33. Final Plat Review for Lot 201 of Artesian Acres Subdivision, Section 2, containing 1 lot
on 5 acres located off Artesian Drive in the 5 th Voting District (1-2026-405).
34. Final Plat Review for King’s Chapel, Section 16, containing 1 lot on 0.78 acres located
off Murfreesboro Road in the 5th Voting District (1-2026-406).
35. Final Plat Review for High Park Hill, Section 5, containing 40 lots on 59.86 acres
located off Murfreesboro Road in the 5th Voting District (1-2026-407).
36. Final Plat Review for The Arbors at Leipers Fork, Section 2, containing 16 lots on 133
acres located off Hargrove Road in the 1st Voting District (1-2026-408).
MINUTES OF THE
WILLIAMSON COUNTY REGIONAL PLANNING COMMISSION
MEETING OF APRIL 9, 2026
MEMBERS PRESENT
Brian Clifford
Don Crohan
Sharon Hatcher
Steve Lane
Jessica Lucyshyn
Keith McCord
Eddie Sanders
STAFF PRESENT
Michael Matteson, Community Development
Director
Aaron V. Holmes, Planning Director
Floyd Heflin, County Engineer
Michael Scott, Ass’t to County Engineer
Kristi Ransom, County Attorney
Lincoln Sweet, Senior Planner
Charlie Waldrop, Planning Technician
Lania Escobar, Office Manager
The Williamson County Regional Planning Commission met in regular session Thursday,
April 9, 2026, at 5:30 p.m. in the Auditorium of the Williamson County Administrative
Complex. Commissioners Bailey, Baldree, Kennedy, McCoy and Richter were unable to
attend.
Vice-Chairman Crohan called the meeting to order and took Roll Call. A quorum was
present.
Vice-Chairman Crohan asked if there were any announcements.
Mr. Holmes announced the following:
• Items 28, 29, 33 and 34 are on the Consent Agenda for Deferral; and
• Public Meeting to present the Draft of the Table of Uses and the Draft Regulations
for the Arrington Village will be held next Wednesday, April 15 th at 6:00 PM at
Arrington Elementary School. The Draft of the Table of Uses and the Draft
Regulations can be found on the County’s website. The flyer and the Drafts are
on the desks.
PUBLIC COMMENTS:
No one signed up to speak.
CONSIDERATION OF MARCH 19, 2026 MINUTES:
Vice-Chairman Crohan asked if there were comments or questions on the Minutes.
Hearing none, he asked for a motion.
Commissioner Lane made a motion to approve the March 19, 2026 Minutes. The motion
was seconded by Commissioner Sanders. The motion was unanimously approved.
CONSENT AGENDA:
Commissioners Hatcher and McCord recused themselves from the Consent Agenda.
Vice-Chairman Crohan asked if there were any items that needed to be discussed
separately. Hearing none, he asked for a motion to accept the Consent Agenda as a
whole.
Williamson County Planning Commission
Meeting of April 20, 2026
Page 2 of 10
Commissioner Sanders made a motion to approve the Consent Agenda per Staff
recommendations. Commissioner Clifford seconded the motion. The motion was
unanimously approved.
BONDS:
3. The Arbors at Leipers Fork – Performance Bond for Water (HB&TS) located off
Hargrove Road. - $536,000
Recommendation: HB&TS Utility District requests this be extended in the current
amount for a period of two (2) months. Staff concurs with this request.
4. The Arbors at Leipers Fork – Performance Bond for Roads, Drainage and Erosion
Control located off Hargrove Road. - $703,000
Recommendation: Reduce to the amount of $469,000 for a period of one (1) year.
5. Arrington Ridge, Section 1 – Maintenance Bond for Roads, Drainage and Erosion
Control located off Cox Road. - $250,000
Recommendation: Extend in the current amount for a period of one (1) year.
6. Blackberry Ridge - Maintenance Bond for Roads, Drainage and Erosion located off
Bending Chestnut Road. - $250,000
Recommendation: Extend in the current amount for a period of one (1) year.
7. Conduit Church – Performance Bond for Landscaping located off Lewisburg Pike. -
$12,850
Recommendation: Extend in the current amount for a period of six (6) months to
allow for replanting.
8. Fairhaven – Performance Bond for Landscaping located off Bethesda Road. - $261,866
Recommendation: Extend in the current amount for six (6) months to allow for
completion.
9. Fiddlers Glen, Section 1 – Performance Bond for Wastewater Collection System located
off Murfreesboro Road. - $178,000
Recommendation: Extend in the current amount for a period of one (1) year.
10. Fiddlers Glen, Section 2 – Performance Bond for Roads, Drainage and Erosion Control
located off Murfreesboro Road. - $553,000
Recommendation: Reduce to the amount of $415,000 for a period of one (1) year.
11. Fiddlers Glen, Section 2 – Performance Bond for Wastewater Collection System
located off Murfreesboro Road.- $60,000
Recommendation: Extend in the current amount for a period of one (1) year.
12. High Park Hill, Section 2 – Maintenance Bond for Wastewater Collection System
located off Murfreesboro Road. - $28,110
Recommendation: Release the bond.
13. Homes at Mulberry Springs Wastewater – Performance Bond for Landscaping located
off Taliaferro Road. - $55,500
Recommendation: Extend for a period of six (6) months to allow for completion.
14. Homes at Mulberry Springs Wastewater – Performance Bond for Wastewater
Treatment and Disposal System located off Taliaferro Road. - $100,200
Recommendation: Extend in the current amount for a period of one (1) year.
Williamson County Planning Commission
Meeting of April 20, 2026
Page 3 of 10
15. Lifepoint Church – Performance Bond for Landscaping located off Clovercroft Road. -
$159,225
Recommendation: Extend for a period of six (6) months to allow for completion.
16. Reeds Vale, Section 4 - Performance Bond for Landscaping located off Lampkins
Bridge Road. - $123,252
Recommendation: Extend for a period of six (6) months to allow for completion.
17. Reeds Vale, Section 4 – Performance Bond for Wastewater Collection System located
off Lampkins Bridge Road. - $360,045.50
Recommendation: Reduce to Maintenance in the amount of $108,013.65 for a period
of two (2) years.
18. Reeds Vale, Section 4 – Performance Bond for Roads, Drainage and Erosion Control
located off Lampkins Bridge Road. - $2,800,000
Recommendation: Reduce to the amount of $1,400,000 for a period of one (1) year.
19. Southall Rural Retreat Wastewater Area – Maintenance Bond for Wastewater
Treatment and Disposal System located off Carters Creek Pike. - $124,700
Recommendation: Release the bond.
20. Southall Rural Retreat Wastewater Area – Maintenance Bond for Wastewater
Collection System located off Carters Creek Pike. - $122,700
Recommendation: Release the bond.
21. Terravista, Section 1 – Maintenance Bond for Roads, Drainage and Erosion Control
located off Long Lane. - $950,000
Recommendation: Extend in the current amount for a period of one (1) year.
22. Terravista, Section 1 – Maintenance Bond for Wastewater Collection System located
off Long Lane. - $45,690
Recommendation: Extend in the current amount for a period of one (1) year.
23. The Mill at Bond Springs, Section 1 – Performance Bond for Roads, Drainage and
Erosion Control located off Bethesda Road. - $300,000
Recommendation: Reduce in the amount of $225,000 for a period of one (1) year.
24. Troubadour Golf Club/Farmstead – Performance Bond or Landscaping located off
Patton Road. - $150,738
Recommendation: Extend in current amount for a period of six (6) months to allow
for completion.
25. Troubadour, Section 2 – Maintenance Bond for Roads, Drainage and Erosion Control
located off Patton Road. - $567,000
Recommendation: Reduce bond to $425,000 for a period of one (1) year; or when
Engineering staff has determined the improvements have been completed and the
bond is ready for review by the Planning Commission; whichever comes first.
26. White Horse Farms – Performance Bond for Landscaping located off Murfreesboro
Road. - $69,369
Recommendation: Extend in the current amount for a period of six (6) months to
allow for completion.
Williamson County Planning Commission
Meeting of April 20, 2026
Page 4 of 10
DEFERRAL ITEMS:
ITEM 28
CONCEPT PLAN REVIEW FOR 3036 OLD MURFREESBORO ROAD SUBDIVISION,
CONTAINING 30 LOTS ON 34.15 ACRES LOCATED OFF OLD MURFREESBORO
ROAD IN THE 5TH VOTING DISTRICT (1-2025-213).
At this time, the applicant is requesting deferral to the May 2026 Planning Commission
Meeting in order to allow the applicant more time to address Staff comments. Staff
concurs with this request.
ITEM 29
PRELIMINARY PLAT REVIEW FOR CHESTNUT HILL FARMS LLE SUBDIVISION,
CONTAINING 5 LOTS ON 28.5 ACRES LOCATED OFF WHIPPOORWILL DRIVE
IN THE 1ST VOTING DISTRICT (1-2025-324).
At this time, the applicant is requesting deferral to the May 2026 Planning Commission
Meeting in order to allow the applicant more time to address Staff comments. Staff
concurs with this request.
ITEM 33
PRELIMINARY PLAT REVIEW FOR JOYBELLE ESTATES SUBDIVISION,
CONTAINING 12 LOTS ON 110.1 ACRES LOCATED OFF EUDAILEY COVINGTON
ROAD IN THE 2ND VOTING DISTRICT (1-2026-304).
At this time, the applicant is requesting deferral to the May 2026 Planning Commission
Meeting in order to allow the applicant more time to address Staff comments. Staff
concurs with this request.
ITEM 34
PRELIMINARY PLAT REVIEW FOR 8828 HORTON HIGHWAY, CONTAINING 5
LOTS ON 28.01 ACRES LOCATED OFF HORTON HIGHWAY IN THE 2ND VOTING
DISTRICT (1-2025-334).
At this time, the applicant is requesting deferral to the May 2026 Planning Commission
Meeting in order to allow the applicant more time to address Staff comments. Staff
concurs with this request.
OLD BUSINESS:
ITEM 27
ROADS, DRAINAGE AND EROSION CONTROL BOND REVIEW OF TERRAVISTA
SUBDIVISION, SECTIONS 1 AND 2.
Brent Thoeny , with True Land Consultants, represented the applicant , The Jones
Company. He reported that Section 2 slope repairs are approved, and the geotechnical
letter has been submitted. The bio pond remains too wet despite drainage efforts; the
team is awaiting drier conditions and will meet with the engineer to evaluate solutions. A
bid has been received for the wastewater road, with paving under consideration pending
Williamson County Planning Commission
Meeting of April 20, 2026
Page 5 of 10
county feedback. Service road construction is anticipated within 30 –45 days. Section 1
bids are under review to confirm scope and timeline. Landscaping (approx. eight trees)
is expected within one to two weeks.
Vice-Chairman Crohan asked if there were any questions. Hearing none, he thanked Mr.
Thoeny.
ITEM 28
CONCEPT PLAN REVIEW FOR 3036 OLD MURFREESBORO ROAD SUBDIVISION,
CONTAINING 30 LOTS ON 34.15 ACRES LOCATED OFF OLD MURFREESBORO
ROAD IN THE 5TH VOTING DISTRICT (1-2025-213).
This Item is on the Consent Agenda as a deferral.
ITEM 29
PRELIMINARY PLAT REVIEW FOR CHESTNUT HILL FARMS LLE SUBDIVISION,
CONTAINING 5 LOTS ON28.5 ACRES LOCATED OFF WHIPPOORWILL DRIVE IN
THE 1ST VOTING DISTRICT (1-2025-324).
This Item is on the Consent Agenda as a deferral.
PUBLIC HEARINGS:
ITEM 30
AMENDMENT TO THE SUBDIVISION REGULATIONS REGARDING EXPIRATION
OF PLATS WITHOUT SURETIES (6-2026-600).
Mr. Holmes reviewed the background (see Staff Report) recommending approval of the
text amendment.
Vice-Chairman Crohan noted that no one signed up for the Public Hearing.
Commissioner Lucyshyn made a motion to approve per Staff recommendation.
Commissioner Sanders seconded the motion. The motion was unanimously approved.
ITEM 31
AMENDMENTS TO ARTICLES 11 AND 23 OF THE ZONING ORDINANCE
REGARDING THE USE OF NONTRADITIONAL WASTEWATER TREATMENT AND
DISPOSAL SYSTEMS WITHIN THE URBAN GROWTH BOUNDARIES (UGB’S) (6-
2026-601).
Mr. Holmes reviewed the background (see Staff Report) recommending approval of the
text amendments and that the attached Resolution be forwarded to the County
Commission for adoption.
Vice-Chairman Crohan noted that no one signed up for the Public Hearing.
Commissioner Clifford asked about the practical effects of prohibiting the systems within
the Urban Growth Boundaries now as compared to before.
Williamson County Planning Commission
Meeting of April 20, 2026
Page 6 of 10
Mr. Holmes advised that all of the properties within the Urban Growth Boundary were
zoned either MGA-1 or MGA-5 or MGA-Hamlet. The newly revised Urban Growth
Boundaries now include properties that are zoned Rural Preservation-5 or Rural
Development-5, and the types of wastewater systems are allowed within the RD-5 and
RP-5 districts. Speaking with the cities, the retrofitting of a non-traditional system to a
municipal system is difficult and costly. The cities asked that these not be permitted in
the Urban Growth Boundaries.
Mr. Matteson added that for many years the policy has been to not allow these systems
in the Growth Boundaries except for individual uses, such as churches or schools. That’s
the same policy that we’ve continued to have and have now. The only difference is that
now there are a few areas within the Growth Boundaries that are zoned RD-5 or RP-5,
and we just want to make sure these same policies we’ve had are reflected in these two
zoning districts when they’re inside the UGBs.
Commissioner Clifford asked if the cities annexed into the UGBs, how would they
connect to those systems.
Mr. Matteson added that the systems would present an impediment to the city’s
annexation because they don’t have those kinds of systems. They have public sewer
and retrofitting the systems would be difficult.
Commissioner Clifford asked about how the average homeowner living within the UGB
feels about the proposed change, about the cost, burden, and how it would affect those
property owners?
Mr. Matteson noted that most people who live within the UGB who want to be annexed
into the city and tap into the city sewer, and to develop their property in conjunction
with the City’s policies on growth and development. He noted the recent addition of
properties to the growth boundaries and the need to be consistent across the board.
Commissioner Clifford asked if a property owner doesn’t have an interest in being
annexed, how will they view the proposed amendment, and if the change would limit
their development options.
Mr. Matteson noted that if a property owner does not want to be annexed, they
probably don’t have designs for developing the property. The property owner would be
limited because they’d be looking at septic or requesting sewer from the municipalities,
which is consistent with the way the policy’s been for many years.
Commissioner Clifford asked how does this align with what the Septic Task Force has
been working on and the recommendations that are forthcoming.
Mr. Matteson responded the proposed amendment doesn’t have a direct bearing,
although if properties within the UGB were developed on septic, then it would to be
easier and less costly to do so. He clarified the proposed amendment would not impede
the new septic regulations.
Commissioner McCord asked if someone has a property at the furthest end of the UGB,
is there an appeal process for this to get a variance to allow use of a wastewater
system.
Mr. Holmes noted any request to use a nontraditional wastewater system where it
wasn’t currently allowed would be considered a use variance, which is something the
BZA can’t grant. An amendment to the Zoning Ordinance would be required to allow the
system where it isn’t currently allowed.
Williamson County Planning Commission
Meeting of April 20, 2026
Page 7 of 10
Commissioner McCord asked for clarification of what options were available for the
property and the property owner.
Mr. Holmes indicated the property could be developed with individual onsite septic
systems.
Mr. Matteson added the RD-5 and RP-5 zoning districts are one unit per five acres, and
that nontraditional wastewater systems aren’t very common for low density
development like that. It’s much more common that septic systems are used.
Vice-Chairman Crohan noted his understanding is that if a property is located within the
UGB area and the city decides to annex the property, that the property owner doesn’t
have a choice unless they were to go to the state. If the property is located within the
UGB, the property has been designated for annexation at some point.
Mr. Matteson responded that the property owner would have the ability to say “I don’t
want to be annexed,” and the cities wouldn’t automatically be able to annex them.
Additionally, there’s also a mechanism for people to request to be removed from the
Urban Growth Boundaries, as they are periodically revisited.
Commissioner Lucyshyn added her understanding was that not allowing the systems
inside the UGB was the policy within the UGBs for some time. It’s only recently, when
the UGBs were redrawn, that some properties ended up inside the UGB that are zoned
RD-5 and RP-5. We’re not putting an undue hardship on them or on anyone within the
UGB.
Mr. Matteson confirmed that she was correct.
Vice-Chairman Crohan asked if there were any other questions. Hearing none, he asked
for a motion.
Commissioner Lucyshyn made a motion to approve per Staff recommendation.
Commissioner Lane seconded the motion.
The motion was unanimously approved.
CONCEPT PLANS:
ITEM 32
CONCEPT PLAN REVIEW FOR WILLOWSTONE ESTATES (AKA CLOVERCROFT
ESTATES), CONTAINING 25 LOTS ON 184.62 ACRES LOCATED OFF
CLOVERCROFT ROAD IN THE 4TH VOTING DISTRICT (1-2025-211).
Mr. Holmes reviewed the background (see Staff Report) recommending approval of this
Concept Plan with the following conditions:
The Preliminary Plat must address the following:
1. Submission of roads, drainage and erosion control plans for review and approval
by the County; and
2. Submission of water plans for review and approval by Nolensville/College Grove
Utility District.
The Final Plat must address the following:
Williamson County Planning Commission
Meeting of April 20, 2026
Page 8 of 10
1. Prior to consideration of Final Plat approval, the applicant shall submit HOA
documents for review and approval by the County Attorney’s office. The HOA
documents must be submitted with the Final Plat, and the approved HOA
documents must be recorded concurrently with the recording of the Final Plat;
2. Establishment of a Performance Bond for roads, drainage and erosion control;
3. Establishment of a Performance Bond for water improvements in favor of
Nolensville/College Grove Utility District;
4. Per the recommendation of the County’s Wastewater Consultant, establishment of
a Performance Bond for the Treatment and Disposal System and the Wastewater
Collection System;
5. Submission of landscaping plans and establishment of a Performance Bond for
landscaping;
6. Execution of Performance Agreements for the above referenced sureties;
7. Execution of a Stormwater Maintenance Agreement and submission of an
Operation and Maintenance Plan for stormwater improvements; and
8. Submission of the approved Final Plat in .dwg format on recordable media based
on the Tennessee State Plane Coordinate System prior to signature and recording
of the plat.
Vice-Chairman Crohan asked if the applicant was present.
Joshua Denton, represented the applicant, and advised that he and the Engineer, Mr.
Wilson, would be available to answer questions.
Commissioner Bailey asked if the development was going to be gated.
Mr. Denton replied that it will not be gated because it connects to an existing development
that has public streets.
Commissioner Bailey asked where the additional lots would be located on the future
revision to the Concept Plan.
Mr. Denton noted the location of where some of the lots could potentially be located. He
referenced the Concept Plan presented at the February meeting and noted there wasn’t
sufficient wastewater capacity for all lots. He explained the Concept Plan has tailored the
number of lots to the capacity of the wastewater system that’s available. He noted any
revisions will be subject to the County’s review and approval.
Commissioner Lucyshyn added that if the applicant wants to revise the Concept Plan why
would he want approval for something that is going to change.
Mr. Denton replied that the current Concept Plan meets the requirements, and that his
client is asking for twenty-five (25) lots. He further noted that there could be a request
for additional lots, and if the expansion to the wastewater system was approved , the
applicant would likely request the additional lots. However, he noted that adding
additional lots might not occur, and so the presented Concept Plan was designed for the
wastewater system’s available capacity, and that it meets all of the County’s criteria, and
they are asking for approval.
Williamson County Planning Commission
Meeting of April 20, 2026
Page 9 of 10
Vice-Chairman Crohan asked if there were any other questions. Hearing none, he asked
for a motion.
Commissioner Clifford made a motion to approve per Staff recommendation .
Commissioner Lane seconded the motion. The motion was unanimously approved.
PRELIMINARY PLATS:
ITEM 33
PRELIMINARY PLAT REVIEW FOR JOYBELLE ESTATES SUBDIVISION,
CONTAINING 12 LOTS ON 110.1 ACRES LOCATED OFF EUDAILEY COVINGTON
ROAD IN THE 2ND VOTING DISTRICT (1-2026-304).
This Item is on the Consent Agenda as a deferral.
ITEM 34
PRELIMINARY PLAT REVIEW FOR 8828 HORTON HIGHWAY, CONTAINING 5
LOTS ON 28.01 ACRES LOCATED OFF HORTON HIGHWAY IN THE 2ND VOTING
DISTRICT (1-2025-334).
This Item is on the Consent Agenda as a deferral.
FINAL PLATS:
ITEM 35
FINAL PLAT REVIEW (REVISED) FOR TALIAFERRO SUBDIVISION,
CONTAINING 27 LOTS ON 196.93 ACRES LOCATED OFF TALIAFERRO ROAD IN
THE 5TH VOTING DISTRICT (1-2026-404).
Mr. Waldrop reviewed the background (see Staff Report) recommending approval of the
Final Plat with the following conditions:
1. The approved HOA documents must be recorded concurrently with the recording
of the Final Plat;
2. Establishment of a Performance Bond for roads, drainage and erosion control in
the amount of $1,122,000, this amount is based on work completed;
3. Per the recommendation of the County’s Wastewater Consultant, establishment of
a Performance Bond for the wastewater collection system in the amount of
$100,200;
4. Posting of a Performance Bond in the amount of $317,500 for water improvements
as specified by Nolensville College Grove Utility District;
5. Establishment of a performance bond for landscaping in the amount of $31,410;
6. Execution of Performance agreements for the above referenced sureties;
7. Execution of a Stormwater Maintenance Agreement and submission of an
Operation and Maintenance Plan for stormwater improvements; and
Williamson County Planning Commission
Meeting of April 20, 2026
Page 10 of 10
8. Providing two (2) copies of the approved Final Plat in .dwg format on recordable
media based on the Tennessee State Plane Coordinate System prior to signature
and recording of the Final Plat.
Vice-Chairman Crohan asked if there were any questions for Staff. Hearing none, he
asked for a motion.
Commissioner Sanders made a motion to approve per Staff recommendations.
Commissioner Clifford seconded the motion. The motion was unanimously approved.
Vice-Chairman Crohan made a motion to adjourn. There being no further business, the
meeting was adjourned at approximately 5:53 p.m.
APPROVED BY A MAJORITY VOTE BY THE WILLIAMSON COUNTY REGIONAL
PLANNING COMMISSION ON MAY 14, 2026
____________________________________
Chairman
CONSENT AGENDA
WILLIAMSON COUNTY REGIONAL PLANNING COMMISSION
WILLIAMSON COUNTY ADMINISTRATIVE COMPLEX
MAY 14, 2026
BONDS:
3. Arrington Woods, Section 1 – Performance Bond for Landscaping located off
Nolensville Road. - $39,576
Recommendation: Extend in the current amount for a period of six (6) months in
order to allow for completion.
4. Arrington Woods, Section 1 – Performance Bond for Roads, Drainage and Erosion
Control located off Nolensville Road. - $263,000
Recommendation: Extend in the current amount for a period of one (1) year.
5. Daventry, Section 1 – Maintenance Bond for Roads, Drainage and Erosion Control
located off Tulloss Road. - $200,000
Recommendation: Reduce to the amount of $100,000 for a period of one (1) year; or
when Engineering staff has determined the improvements have been completed and
the bond is ready for review by the Planning Commission, whichever comes first.
6. Daventry, Section 3 - Maintenance Bond for Roads, Drainage and Erosion located off
Tulloss Road. - $185,000
Recommendation: Reduce to the amount of $93,000 for a period of one (1) year; or
when Engineering staff has determined the improvements have been completed and
the bond is ready for review by the Planning Commission, whichever comes first.
7. Enclave at Dove lake, Section 2 – Maintenance Bond for Roads, Drainage and Erosion
Control located off Nolensville Road. - $550,000
Recommendation: Extend in the current amount for a period of one (1) year.
8. Fiddlers Glen/Cox Ladd Treatment Facility – Maintenance Bond for Landscaping
located off Murfreesboro Road. - $3,000
Recommendation: Extend in the current amount for a period of six (6) months in order
to allow for completion.
9. Fiddlers Glen, Section 1 – Performance Bond for Roads, Drainage and Erosion Control
located off Murfreesboro Road. - $2,887,000
Recommendation: Reduce to the amount of $2,165,000 for a period of one (1) year.
10. Hardeman Springs, Section 1 – Maintenance Bond for Roads, Drainage and Erosion
Control located off Murfreesboro Road. - $400,000
Recommendation: Extend in the current amount for a period of one (1) year.
11. Hart’s Landmark – Maintenance Bond for Sewer Improvements located off Hartland
Drive. - $20,000
Recommendation: Harpeth Wastewater Cooperative is requesting this bond be
extended in the current amount for a period of one (1) year. Staff concurs with this
request.
12. High Park Hill Amenity - Performance Bond for Landscaping off Murfreesboro Road. -
$167,079
Recommendation: Extend in the current amount for six (6) months in order to allow
for completion.
13. High Park Hill Amenity – Performance Bond for Wastewater Collection System located
off Murfreesboro Road. - $12,120
Recommendation: Reduce to Maintenance in the amount of $3,636 for a period of
two (2) years.
14. High Park Hill, Section 4 – Performance Bond for Roads, Drainage and Erosion Control
located off Murfreesboro Road. - $850,000
Recommendation: Extend in the current amount for a period of one (1) year.
15. Reeds Vale Amenity Center - Performance Bond for Landscaping located off Lampkins
Bridge Road. - $29,755
Recommendation: Extend in the current amount for a period of six (6) months in order
to allow for completion.
16. Reeds Vale, Section 1 – Maintenance Bond for Roads, Drainage and Erosion Control
located off Lampkins Bridge Road. - $1,000,000
Recommendation: Reduce to the amount of $850,000 for a period of one (1) year.
17. Reeds Vale, Section 2 – Performance Bond for Landscaping located off Lampkins
Bridge Road. - $46,849
Recommendation: Extend in the current amount for a period of six (6) months in
order to allow for completion.
18. St. Barbara’s Coptic Church – Maintenance Bond for Landscaping located off
Clovercroft Road. - $65,000
Recommendation: Release the bond.
19. St. Marlo, Section 3 – Maintenance Bond for Wastewater Collection System located
off Long Lane. - $57,200
Recommendation: Release the bond.
20. Taliaferro Subdivision – Performance Bond for Landscaping located off Taliaferro
Road. - $31,410
Recommendation: Release the bond.
21. Taliaferro Subdivision – Performance Bond for Roads, Drainage and Erosion Control
located off Taliaferro Road. - $1,122,000
Recommendation: Extend in the current amount for a period of one (1) year.
22. Vista Creek – Performance Bond or Landscaping located off Old Hillsboro Road. -
$47,484
Recommendation: Release the bond.
DEFERRAL ITEMS:
ITEM 24
PRELIMINARY PLAT REVIEW FOR LOT 1 OF THE LARRY U. TURNER PROPERTY
LLE SUBDIVISION, CONTAINING 1 LOT ON 20.33 ACRES LOCATED OFF CARL
ROAD IN THE 5TH VOTING DISTRICT (1-2026-301).
At this time, the applicant is requesting deferral to the August 2026 Planning Commission
Meeting in order to allow the applicant more time to address Staff comments. Staff
concurs with this request.
ITEM 30
PRELIMINARY PLAT REVIEW FOR DODD FAMILY REVOCABLE LIVING TRUST
SUBDIVISION, CONTAINING 1 LOT ON 32.12 ACRES LOCATED OFF
TALIAFERRO ROAD IN THE 5TH VOTING DISTRICT (1-2026-305)
At this time, the applicant is requesting deferral to the June 2026 Planning Commission
Meeting in order to allow the applicant more time to address Staff comments. Staff
concurs with this request.
ITEM 32
FINAL PLAT REVIEW FOR FOSTER SUBDIVISION FAMILY SUBDIVISION,
CONTAINING 1 LOT ON 1.40 ACRES LOCATED OFF TALIAFERRO ROAD IN THE
5TH VOTING DISTRICT (1-2026-409)
At this time, the applicant is requesting deferral to the June 2026 Planning Commission
Meeting in order to allow the applicant more time to address Staff comments. Staff
concurs with this request.
ITEM 35
FINAL PLAT REVIEW FOR HIGH PARK HILL SUBDIVISION, SECTION 5,
CONTAINING 40 LOTS ON 59.86 ACRES LOCATED OFF MURFREESBORO ROAD
IN THE 5TH VOTING DISTRICT (1-2026-407).
At this time, the applicant is requesting deferral to the June 2026 Planning Commission
Meeting in order to allow the applicant more time to address Staff comments. Staff
concurs with this request.
FINAL PLATS
ITEM 36
FINAL PLAT REVIEW FOR ARBORS OF LEIPERS FORK SUBDIVISION, SECTION
2, CONTAINING 16 LOTS ON 133 ACRES LOCATED OFF HARGROVE ROAD IN
THE 1ST VOTING DISTRICT (1-2026-408).
Staff recommends approval of the Final Plat with the following conditions:
1. The HOA documents shall address the requirements of Section 17.11: Gated
Subdivisions and Section 17.12: Private Streets of the Zoning Ordinance . The
approved HOA documents must be recorded concurrently with the recording of
the Final Plat.
2. Execution of Performance Agreements for the above referenced sureties;
3. Execution of a Stormwater Maintenance Agreement and submission of an
Operation and Maintenance Plan for stormwater improvements; and
4. Providing two (2) copies of the approved Final Plat in .dwg format on recordable
media based on the Tennessee State Plane Coordinate System prior to signature
and recording of the Final Plat.
MOTION TO ACCEPT STAFF RECOMMENDATION
1st _____ 2nd ______ VOTE: ___________
NOTE: All matters listed under the consent agenda are considered to be routine.
There will be no separate discussion of these items unless a Planning
Commission member so requests, in which case it will be removed from the
Consent Agenda so that discussion may be held on that item.
Reviewer: OCW
Date: 05/14/2026
ITEM 3
NAME: ARRINGTON WOODS, SECTION 1
BOND TYPE: PERFORMANCE BOND FOR LANDSCAPING
LOCATION: OFF NOLENSVILLE ROAD
BACKGROUND: The following table shows the previous history of the bond.
MEETING DATE BOND TYPE ACTION TAKEN BOND AMOUNT
January 2025 Performance Implemented $39,576
LAST ACTION: At the January 2025 meeting, this body granted approval of this final
plat with the following conditions: 1) The HOA documents shall address the requirements
of Section 17.11: Gated Subdivisions and Section 17.12: Private Streets of the Zoning
Ordinance. The HOA documents must be approved prior to the recording of the plat and
the approved HOA documents must be recorded concurrently with the recording of the
Final Plat; 2) A permit for the security gate will need to be obtained prior to its installation,
and all requirements for such gates as outlined in Section 17.11 of the Zoning Ordinance
must be met; 3) Establishment of a Performance Bond for roads, drainage and erosion
control in the amount of $ 327,000. This amount is based on work completed ; 4)
Establishment of a performance bond for landscaping in the amount of $39,576; 5)
Posting of a Performanc e Bond in the amount of $462,500 for water improvements as
specified by Nolensville College Grove Utility District ; 6) Execution of Performance
agreements for the above referenced sureties; 7) Execution of a Stormwater Maintenance
Agreement and submission of an Operation and Maintenance Plan for stormwater
improvements; and 8) Providing two (2) copies of the approved Final Plat in .dwg format
on recordable media based on the Tennessee State Plane Coordinate System prior to
signature and recording of the Final Plat.
RECOMMENDATION: Staff visited the site and noted that the landscaping had not been
installed. Staff recommends extending the bond for a period of six (6) months in order
to allow for completion.
CURRENT RECOMMENDED
$39,576 $39,576
Performance Performance
Reviewer: MS
Date: 05/14/2026
ITEM 4
NAME: ARRINGTON WOODS, SECTION 1
BOND TYPE: PERFORMANCE BOND FOR ROADS, DRAINAGE AND
EROSION CONTROL
LOCATION: OFF NOLENSVILLE ROAD
BACKGROUND: The following table shows the previous history of the bond.
MEETING DATE BOND TYPE ACTION TAKEN BOND AMOUNT
January 2025 Performance Implemented $263,000
LAST ACTION: At the January 2025 meeting, this body granted approval of this final
plat with the following conditions: 1) The HOA documents shall address the requirements
of Section 17.11: Gated Subdivisions and Section 17.12: Private Streets of the Zoning
Ordinance. The HOA documents must be approved prior to the recording of the plat and
the approved HOA documents must be recorded concurrently with the recording of the
Final Plat; 2) A permit for the security gate will need to be obtained prior to its installation,
and all requirements for such gates as outlined in Section 17.11 of the Zoning Ordinance
must be met; 3) Establishment of a Performance Bond for roads, drainage and erosion
control in the amount of $ 327,000. This amount is based on work completed ; 4)
Establishment of a performance bond for landscaping in the amount of $39,576; 5)
Posting of a Performanc e Bond in the amount of $462,500 for water improvements as
specified by Nolensville College Grove Utility District ; 6) Execution of Performance
agreements for the above referenced sureties; 7) Execution of a Stormwater Maintenance
Agreement and submission of an Operation and Maintenance Plan for stormwater
improvements; and 8) Providing two (2) copies of the approved Final Plat in .dwg format
on recordable media based on the Tennessee State Plane Coordinate System prior to
signature and recording of the Final Plat.
RECOMMENDATION: Staff visited the site and noted that some improvements have
been completed. Staff recommends that the Performance Bond be extended in the
current amount for a period of one (1) year.
CURRENT RECOMMENDED
$263,000 $263,000
Performance Performance
Reviewer: MS
Date: 05/14/2026
ITEM 5
NAME: DAVENTRY, SECTION 1
BOND TYPE: MAINTENANCE BOND FOR ROADS, DRAINAGE AND
EROSION CONTROL
LOCATION: TULLOSS RD
BACKGROUND: The following table shows the previous history of the bond.
MEETING DATE BOND TYPE ACTION TAKEN BOND AMOUNT
July 2019 Performance RDE Implemented $200,000
July 2020 Performance RDE Extend $200,000
July 2021 Performance RDE Extend $200,000
July 2022 Performance RDE Extend $200,000
November 2023 Performance RDE Convert to Maint
& Extend
$200,000
May 2024 Maintenance RDE Extend $200,000
May 2025 Maintenance RDE Extend $200,000
LAST ACTION: At the May 2025 meeting, this body granted approval to extend this
bond in the current amount for a period of one (1) year.
RECOMMENDATION: Staff visited the site and noted that most of the improvements
are complete. The applicant has requested a release of the bond, however, there are
items that still need to be completed prior to bond release. St aff recommends that the
Maintenance Bond be reduced to the amount of $100,000 for a period of one (1) year;
or when Engineering staff has determined the improvements have been completed and
the bond is ready for review by the Planning Commission, whichever comes first.
CURRENT RECOMMENDED
$200,000 $100,000
Maintenance Maintenance
Reviewer: MS
Date: 05/14/2026
ITEM 6
NAME: DAVENTRY, SECTION 3
BOND TYPE: MAINTENANCE BOND FOR ROADS, DRAINAGE AND
EROSION CONTROL
LOCATION: OFF TULLOSS ROAD
BACKGROUND: The following table shows the previous history of the bond.
MEETING DATE BOND TYPE ACTION TAKEN BOND AMOUNT
June 2021 Performance RDE Implemented $370,000
May 2022 Performance RDE Extend $370,000
March 2023 Performance RDE Convert to Maint
& Extend
$370,000
May 2024 Maintenance RDE Extend $370,000
May 2025 Maintenance RDE Extend & Reduce $185,000
LAST ACTION: At the May 2025 meeting, this body granted approval to extend and
reduce the bond for a period one (1) year.
RECOMMENDATION: Staff visited the site and noted that most of the improvements
are complete. The applicant has requested a release of the bond, however, there are
items that still need to be completed prior to bond release. St aff recommends that the
Maintenance Bond be reduced to the amount of $93,000 for a period of one (1) year; or
when Engineering staff has determined the improvements ha ve been completed and the
bond is ready for review by the Planning Commission, whichever comes first.
CURRENT RECOMMENDED
$185,000 $93,000
Maintenance Maintenance
Reviewer: MS
Date: 05/14/2026
ITEM 7
NAME: ENCLAVE AT DOVE LAKE, SECTION 2
BOND TYPE: MAINTENANCE BOND FOR ROADS, DRAINAGE AND
EROSION CONTROL
LOCATION: OFF NOLENSVILLE ROAD
BACKGROUND: The following table shows the previous history of the bond.
MEETING DATE BOND TYPE ACTION TAKEN BOND AMOUNT
April 2021 Performance RDE Implemented $1,100,000
May 2022 Performance RDE Reduce to Maint &
Extend
$550,000
May 2023 Maintenance RDE Extend $550,000
May 2024 Maintenance RDE Extend $550,000
May 2025 Maintenance RDE Extend $550,000
LAST ACTION: At the May 2025 meeting, this body granted approval to extend this
bond in the current amount for a period of one (1) year.
RECOMMENDATION: Staff visited the site and noted that some improvements have
been completed. Staff recommends that t he Maintenance bond be extended in the
current amount for a period of one (1) year.
CURRENT RECOMMENDED
$550,000 $550,000
Maintenance Maintenance
Reviewer: OCW
Date: 05/14/2026
ITEM 8
NAME: FIDDLERS GLEN/COX LADD TREATMENT FACILITY
BOND TYPE: MAINTENANCE BOND FOR LANDSCAPING
LOCATION: OFF MURFREESBORO ROAD
BACKGROUND: The following table shows the previous history of the bond.
MEETING
DATE
BOND TYPE ACTION TAKEN BOND
AMOUNT
May 2020 Performance
Landscaping
Implemented $27,400
January 2024 Performance
Landscaping
Extend $27,400
July 2024 Performance
Landscaping
Reduce to
Maintenance &
Extend
$3,000
July 2025 Maintenance
Landscaping
Extend $3,000
December 2025 Maintenance
Landscaping
Extend $3,000
LAST ACTION: At the December 2025 meeting, this body granted approval to extend
this maintenance bond in the amount for a period of six (6) months.
RECOMMENDATION: Staff visited the site and noted that the landscaping had not
been installed. Staff recommends extending the bond for a period of six (6) months in
order to allow for completion.
CURRENT RECOMMENDED
$3,000 $3,000
Maintenance Maintenance
Reviewer: MS
Date: 05/14/2026
ITEM 9
NAME: FIDDLERS GLEN, SECTION 1
BOND TYPE: PERFORMANCE BOND FOR ROADS, DRAINAGE AND
EROSION CONTROL
LOCATION: OFF MURFREESBORO ROAD
BACKGROUND: The following table shows the previous history of the bond.
MEETING DATE BOND TYPE ACTION TAKEN BOND AMOUNT
March 2023 Performance RDE Implemented $2,887,000
February 2024 Performance RDE Extend $2,887,000
February 2025 Performance RDE Extend $2,887,000
LAST ACTION: At the February 2025 meeting, this body granted approval to extend
this bond in the current amount for a period of one (1) year.
RECOMMENDATION: Staff visited the site and noted that some improvements have
been completed. Staff recommends that the Performance Bond be reduced to the
amount of $2,165,000 for a period of one (1) year.
CURRENT RECOMMENDED
$2,887,000 $2,165,000
Performance Performance
Reviewer: MS
Date: 05/14/2026
ITEM 10
NAME: HARDEMAN SPRINGS, SECTION 1
BOND TYPE: MAINTENANCE BOND FOR ROADS, DRAINAGE AND
EROSION CONTROL
LOCATION: OFF MURFREESBORO ROAD
BACKGROUND: The following table shows the previous history of the bond.
MEETING DATE BOND TYPE ACTION TAKEN BOND AMOUNT
May 2019 Performance RDE Implemented $550,000
May 2020 Performance RDE Extend $550,000
May 2021 Performance RDE Extend $550,000
May 2022 Performance RDE Reduce to
Maintenance &
Extend
$500,000
May 2023 Maintenance RDE Extend $500,000
May 2024 Maintenance RDE Extend $500,000
May 2025 Maintenance RDE Extend & Reduce $400,000
LAST ACTION: At the May 2025 meeting, this body granted approval to reduce this
Maintenance Bond and extend for a period of one (1) year.
RECOMMENDATION: Staff visited the site and noted that some improvements have
been completed. Staff recommends that the Maintenance Bond be extended in the
current amount for a period of one (1) y ear.
CURRENT RECOMMENDED
$400,000 $400,000
Maintenance Maintenance
REVIEWER: LE
DATE: 05/14/2026
ITEM 11
NAME: HART’S LANDMARK
BOND TYPE: MAINTENANCE BOND FOR SEWER IMPROVEMENTS
(Harpeth Wastewater Cooperative)
LOCATION: Hartland Drive
BACKGROUND: The following table shows the previous history of the bond.
MEETING DATE BOND TYPE ACTION TAKEN BOND AMOUNT
May 2014 Performance Sewer Implemented $85,970
May 2015 Performance Sewer Extend $85,970
May 2016 Performance Sewer Extend $85,970
May 2017 Performance Sewer Extend $85,970
May 2018 Performance Sewer Extend $85,970
May 2019 Performance Sewer Extend $85,970
November 2019 Performance Sewer Reduce to
Maintenance &
Extend
$40,000
November 2020 Maintenance Sewer Extend $40,000
May 2021 Maintenance Sewer Reduce & Extend $20,000
May 2022 Maintenance Sewer Extend $20,000
May 2023 Maintenance Sewer Extend $20,000
May 2024 Maintenance Sewer Extend $20,000
May 2025 Maintenance Sewer Extend $20,000
LAST ACTION: At the May 2025 meeting, this body granted approval to extend this
bond in the current amount for a period of one (1) year.
RECOMMENDATION: Harpeth Wastewater Cooperative is requesting this bond be
extended in the current amount for a period of one (1) year. Staff concurs with this
request.
CURRENT RECOMMENDED
$20,000 $20,000
Maintenance Maintenance
Reviewer: OCW
Date: 05/14/2026
ITEM 12
NAME: HIGH PARK HILL AMENITY
BOND TYPE: PERFORMANCE BOND FOR LANDSCAPING
LOCATION: OFF MURFREESBORO ROAD
BACKGROUND: The following table shows the previous history of the bond.
MEETING DATE BOND TYPE ACTION TAKEN BOND AMOUNT
May 2025 Performance Implemented $167,079
LAST ACTION: At the May 2025 meeting, this body granted approval of this Site Plan
with the following conditions: 1.) Prior to the recording of the Final Plat of the Section in
which the Amenity Center is located, the HOA documents shall be revised to be consistent
with the requirements and limitations of the Private Recreational Center Use Type as
described by the Zoning Ordinance; 2.) Per the recommendation of the County’s
Wastewater Consultant, the posting of a Performance Bond for the Collection System in
the amount of $12,120; 3.) Posting of a Performance Bond for landscaping improvements
in the amount of $167,079; and 4.) Execution of a Performance Agreement for the above
referenced surety.
RECOMMENDATION: Staff visited the site and noted that most of the landscaping had
been installed, but some trees along the entrance had not been installed. Staff
recommends extending the bond for a period of six (6) months in order to allow for
completion.
CURRENT RECOMMENDED
$167,079 $167,079
Performance Performance
Reviewer: AVH
Date: 05/14/2026
ITEM 13
NAME: HIGH PARK HILL AMENITY
BOND TYPE: PERFORMANCE BOND FOR WASTEWATER COLLECTION
SYSTEM
LOCATION: OFF MURFREESBORO ROAD
BACKGROUND: The following table shows the previous history of the bond.
MEETING DATE BOND TYPE ACTION TAKEN BOND AMOUNT
May 2025 Performance Implemented $12,120
LAST ACTION: At the May 2025 meeting, this body granted approval of this Site Plan
with the following conditions: 1.) Prior to the recording of the Final Plat of the Section in
which the Amenity Center is located, the HOA documents shall be revised to be consistent
with the requirements and limitations of the Private Recreational Center Use Type as
described by the Zoning Ordinance; 2.) Per the recommendation of the County’s
Wastewater Consultant, the posting of a Performance Bond for the Collection System in
the amount of $12,120; 3.) Posting of a Performance Bond for landscaping improvements
in the amount of $167,079; and 4.) Execution of a Performance Agreement for the above-
referenced surety.
RECOMMENDATION: Build-out for this development has been achieved, and we are
in receipt of the required certification letters. Accordingly, it is recomme nded that this
bond be reduced to maintenance in the amount of $3,636 for a period of two (2) years.
CURRENT RECOMMENDED
$12,120 $3,636
Performance Maintenance
Reviewer: MS
Date: 05/14/2026
ITEM 14
NAME: HIGH PARK HILL, SECTION 4
BOND TYPE: PERFORMANCE BOND FOR ROADS, DRAINAGE AND
EROSION CONTROL
LOCATION: OFF MURFREESBORO RD
BACKGROUND: The following table shows the previous history of the bond.
MEETING
DATE
BOND TYPE ACTION TAKEN BOND
AMOUNT
February 2025 Performance RDE Implemented $1,000,000
August 2025 Performance RDE Extend & Reduce $850,000
LAST ACTION: At the August 2025 meeting, this body granted approval Extend and
Reduce in the current amount for a period of one (1) yea r.
RECOMMENDATION: Staff visited the site and noted that some improvements have
been completed. Staff recommends that the Performance Bond be extended in the
current amount for a period of one (1) year.
CURRENT RECOMMENDED
$850,000 $850,000
Performance Performance
Reviewer: OCW
Date: 05/14/2026
ITEM 15
NAME: REEDS VALE AMENITY CENTER
BOND TYPE: PERFORMANCE BOND FOR LANDSCAPING
LOCATION: OFF LAMPKINS BRIDGE ROAD
BACKGROUND: The following table shows the previous history of the bond.
MEETING DATE BOND TYPE ACTION TAKEN BOND AMOUNT
November 2023 Performance
Landscaping
Implemented $29,755
December 2024 Performance
Landscaping
Extend $29,755
June 2025 Performance
Landscaping
Extend $29,755
December 2025 Performance
Landscaping
Extend $29,755
LAST ACTION: At the December 2025 meeting, this body granted approval to extend
this bond in the current amount for a period of six (6) months.
RECOMMENDATION: Staff visited the site and noted that most of the landscaping
had been installed, but some trees had not been installed along the western property
line. Staff recommends extending the bond for a period of six (6) months in order to
allow for completion.
CURRENT RECOMMENDED
$29,755 $29,755
Performance Performance
Reviewer: MS
Date: 05/14/2026
ITEM 16
NAME: REEDS VALE, SECTION 1
BOND TYPE: MAINTENANCE BOND FOR ROADS, DRAINAGE AND
EROSION CONTROL
LOCATION: OFF LAMPKINS BRIDGE ROAD
BACKGROUND: The following table shows the previous history of the bond.
MEETING DATE BOND TYPE ACTION TAKEN BOND AMOUNT
May 2023 Performance RDE Implemented $2,781,000
May 2024 Performance RDE Reduce to
Maintenance &
Extend
$1,391,000
May 2025 Maintenance RDE Reduce & Extend $1,000,000
LAST ACTION: At the May 2025 meeting, this body granted approval to reduce this
bond in the current amount for a period of one (1) year.
RECOMMENDATION
: Staff visited the site and noted that some improve ments have
been completed. Staff recommends that the Maintenan ce Bond be reduced to the
amount of $850,000 for a period of one (1) year.
CURRENT RECOMMENDED
$1,000,000 $850,000
Maintenance Maintenance
Reviewer: OCW
Date: 05/14/2026
ITEM 17
NAME: REEDS VALE, SECTION 2
BOND TYPE: PERFORMANCE BOND FOR LANDSCAPING
LOCATION: OFF LAMPKINS BRIDGE ROAD
BACKGROUND: The following table shows the previous history of the bond.
MEETING DATE BOND TYPE ACTION TAKEN BOND AMOUNT
December 2023 Performance
Landscaping
Implemented $46,849
December 2024 Performance
Landscaping
Extend $46,849
June 2025 Performance
Landscaping
Extend $46,849
December 2025 Performance
Landscaping
Extend $46,849
LAST ACTION: At the December 2025 meeting, this body granted approval to extend
this bond in the current amount for a period of six (6) months.
RECOMMENDATION: Staff visited the site and noted that most of the landscaping
had been installed, but some trees had not been installed near the Ladd Road entrance.
Staff recommends extending the bond for a period of six (6) months in order to allow
for completion.
CURRENT RECOMMENDED
$46,849 $46,849
Performance Performance
Reviewer: OCW
Date: 05/14/2026
ITEM 18
NAME: ST. BARBARA’S COPTIC CHURCH
BOND TYPE: MAINTENANCE BOND FOR LANDSCAPING
LOCATION: OFF CLOVERCROFT ROAD
BACKGROUND: The following table shows the previous history of the bond.
MEETING DATE BOND TYPE ACTION TAKEN BOND AMOUNT
July 2023 Performance
Landscaping
Implemented $213,917
December 2024 Performance
Landscaping
Defer $213,917
January 2025 Performance
Landscaping
Reduce to
Maintenance &
Extend
$65,000
December 2025 Performance
Landscaping
Extend $65,000
LAST ACTION: At the December 2025 meeting, Staff recommends this bond be
Extended in the current amount for a period of six (6) months.
RECOMMENDATION: Staff visited the site and noted that the required landscaping
had been installed per the plan. Staff recommends releasing the bond.
CURRENT RECOMMENDED
$65,000
Maintenance Release
Reviewer: AVH
Date: 05/14/2026
ITEM 19
NAME: ST. MARLO, SECTION 3
BOND TYPE: MAINTENANCE BOND FOR WASTEWATER COLLECTION
SYSTEM
LOCATION: OFF LONG LANE
BACKGROUND: The following table shows the previous history of the bond.
MEETING
DATE
BOND TYPE ACTION TAKEN BOND
AMOUNT
January 2023 Performance WW
Collection System Implemented $57,200
January 2024 Performance WW
Collection System Implemented $57,200
May 2024 Performance WW
Collection System
Extend & Reduce
to Maintenance $17,160
LAST ACTION: At the May 2024 meeting, this body granted approval to extend this
bond to Maintenance and Reduce in the current amount for a period of one (2) year.
RECOMMENDATION: This bond has satisfied the requisite two (2) year maintenance
period. Therefore, Staff recommends releasing the bond.
CURRENT RECOMMENDED
$57,200
Maintenance Release
Reviewer: OCW
Date: 05/14/2026
ITEM 20
NAME: TALIAFERRO SUBDIVISION
BOND TYPE: PERFORMANCE BOND FOR LANDSCAPING
LOCATION: OFF TALIFERRO ROAD
BACKGROUND: The following table shows the previous history of the bond.
MEETING DATE BOND TYPE ACTION TAKEN BOND AMOUNT
June 2025 Performance Implemented $31,410
LAST ACTION: At the June 2025 meeting, this body granted approval of this Final Plat
with the following conditions: 1.) The approved HOA documents must be recorded
concurrently with the recording of the Final Plat; 2.) Establishment of a Performance Bond
for roads, drainage and erosion control in the amount of $1,122,000, this amount is based
on work completed; 3.) Per the recommendation of the County’s Wastewater Consultant,
establishment of a Performance Bond for the wastewater collection system in the amount
of $100,200; 4.) Posting of a Performanc e Bond in the amount of $317,500 for water
improvements as specified by Nolensville/Grove Utility District; 5.) Establishment of a
performance bond for landscaping in the amount of $31,410; 6.) Execution of
Performance agreements for the above referenced sureties; 7.) Execution of a
Stormwater Maintenance Agreement and submission of an Operation and Maintenance
Plan for stormwater improvements; and 8.) Providing two (2) copies of the approved
Final Plat in .dwg format on recordable media based on the Tennessee State Plane
Coordinate System prior to signature and recording of the Final Plat.
RECOMMENDATION: Staff visited the site and noted that the required landscaping had
been installed per the plan. Staff recommends releasing the bond.
CURRENT RECOMMENDED
$31,410
Performance Release
Reviewer: MS
Date: 05/14/2026
ITEM 21
NAME: TALIAFERRO SUBDIVISION
BOND TYPE: PERFORMANCE BOND FOR ROADS, DRAINAGE AND
EROSION CONTROL
LOCATION: OFF TALIFERRO ROAD
BACKGROUND: The following table shows the previous history of the bond.
MEETING DATE BOND TYPE ACTION TAKEN BOND AMOUNT
June 2025 Performance Implemented $1,122,000
LAST ACTION: At the June 2025 meeting, this body granted approval of this Final Plat
with the following conditions: 1.) The approved HOA documents must be recorded
concurrently with the recording of the Final Plat; 2.) Establishment of a Performance Bond
for roads, drainage and erosion control in the amount of $1,122,000, this amount is based
on work completed; 3.) Per the recommendation of the County’s Wastewater Consultant,
establishment of a Performance Bond for the wastewater collection system in the amount
of $100,200; 4.) Posting of a Performanc e Bond in the amount of $317,500 for water
improvements as specified by Nolensville/Grove Utility District; 5.) Establishment of a
performance bond for la ndscaping in the amount of $31,410; 6.) Execution of
Performance agreements for the above referenced sureties; 7.) Execution of a
Stormwater Maintenance Agreement and submission of an Operation and Maintenance
Plan for stormwater improvements; and 8.) Providing two (2) copies of the approved
Final Plat in .dwg format on recordable media based on the Tennessee State Plane
Coordinate System prior to signature and recording of the Final Plat.
RECOMMENDATION: Staff visited the site and noted that some improvem ents have
been completed. Staff recommends that the Performance Bond be extended in the
current amount for a period of one (1) year.
CURRENT RECOMMENDED
$1,122,000 $1,122,000
Performance Performance
Reviewer: OCW
Date: 05/14/2026
ITEM 22
NAME: VISTA CREEK
BOND TYPE: PERFORMANCE BOND FOR LANDSCAPING
LOCATION: OFF OLD HILLSBORO ROAD
BACKGROUND: The following table shows the previous history of the bond.
MEETING
DATE
BOND TYPE ACTION TAKEN BOND
AMOUNT
November 2024 Performance
Landscaping
Implemented $47,484
December 2025 Performance
Landscaping
Extend $47,484
LAST ACTION: At the December 2025 meeting, Staff recommended this bond be
extended in the current amount for a period of six (6) months to allow completion.
RECOMMENDATION: Staff visited the site and noted that the required landscaping
had been installed per the plan. Staff recommends releasing the bond.
CURRENT RECOMMENDED
$47,484
Implement Release
Item 23—Page 1 of 1
Date: 5-14-2026
ITEM 23
TERRAVISTA ROADS, DRAINAGE, AND EROSION CONTROL BOND UPDATE
Item 24—Page 1 of 1
Reviewer: LS
Date: 5/14/2026
ITEM 24
PRELIMINARY PLAT REVIEW FOR LOT 1 OF THE LARRY U. TURNER PROPERTY
LLE SUBDIVISION, CONTAINING 1 LOT ON 20.33 ACRES LOCATED OFF CARL
ROAD IN THE 5TH VOTING DISTRICT (1-2026-301).
Area 20.33 acres
Zoning Rural Development-5
Lots 1
Water Individual Well
Sewer Individual On-Site Septic Systems
Development Option Large Lot Easement
Chapter 1101 Status Rural
Map and Parcel 159---01104
File Number (1-2026-301)
At this time, the applicant is requesting deferral to the August 2026 Planning
Commission Meeting in order to allow the applicant more time to address Staff
comments. Staff concurs with this request.
Item 25—Page 1 of 3
Reviewer: JYJ
Date: 5/14/2026
ITEM 25
CONCEPT PLAN REVIEW FOR WILSON BRANCH FARMS (AKA 3036 OLD
MURFREESBORO ROAD ) SUBDIVISION, CONTAINING 28 LOTS ON 34.15
ACRES LOCATED OFF OLD MURFREESBORO ROAD IN THE 5 TH VOTING
DISTRICT (1-2025-213).
Attachment 25-1 Concept Plan
25-2 Aerial Photograph
Area 34.15 acres (0.84 DU/A)
Lots 28
Zoning Triune Character Area–2 (TCA-2)
Water Nolensville/College Grove Utility District
Sewer Triune Sewer Facility
Development Options Major Traditional Subdivision
Chapter 1101 Status PGA
Map and Parcels 113—038.00; 040.00 and 040.01
File Number (1-2025-213)
The applicant is requestin g Concept Plan approval for a 28 -lot Major Traditional
Subdivision in the Triune Character Area–2 (TCA-2) district. Concept Plan approval is the
first stage in the development process.
The proposed development consists of twenty -eight (28) lots, which range in size from
21,780 to 32,644 square feet, with an average lot size of 23,907 square feet. The overall
density is 0.84 dwelling units per acre. Surrounding properties range in size from one
(1) acre to ninety-one (91) acres and are used for residential or agricultural purposes.
The subject propert ies total approximately 34 acres in size and are located off Old
Murfreesboro Road approximately a quarter mile east of Nolensville Road . The site
contains a number of natural resources, including moderate and very steep slopes, a
Waterway Natural Area (WNA), wetlands and some woodlands. Approximately forty-five
percent (45%) of the site will be preserved in Open Space, and ninety-one percent (91%)
of the existing tree canopy will be retained. Natural Resource Protections standards have
been met.
The required Open Space strip around the perimeter of the property has been provided.
Water service will be provided by the Nolensville/College Grove Utility District , and
wastewater will be handled via the Triune Sewer Facility. Staff has confirmed the property
is in the service ar ea and the system has adequate capacity to serve the proposed
Item 25—Page 2 of 3
Reviewer: JYJ
Date: 5/14/2026
subdivision, and all bonds associated with said system will be established during the Final
Plat stage.
Access is provided by a single entrance off Old Murfreesboro Road. The internal roadway
network will be publicly maintained. N o off-site roadway improvements are required in
conjunction with this development.
Within the TCA-2 zoning district where the Triune Special Area Plan shows a potential
greenway on a development property, the developer is required to construct a
greenway trail and provide a Public Access Easement. The Triune Special Area Plan
shows a greenway transecting the property and the applican t has provided a fifteen
(15) foot greenway easement and a twelve (12) foot paved trail along Wilson Branch.
Additionally, the applicant has provided a twenty-five (25) foot greenway easement
along the northern property line to accommodate a potential future trail . The greenway
located along the Wilson Branch must be constructed prior to submittal of the Final Plat
for the section in which it is located. This has been added as a condition of approval.
It should be noted that once detailed construction and engineering plans are prepared in
conjunction with the submittal of a Preli minary Plat, changes to the layout, including the
potential for a reduction of lots and relocation of drainage infrastructure, may be
necessary. A Landscaping Plan will also be required.
The Concept Plan is in order, and Staff recommends approval with th e following
conditions:
The Preliminary Plat must address the following:
1. Submission of roads, drainage and erosion control plans for review and approval
by the County;
2. Submission of road names for review and approval by the Williamson County
Emergency Management Agency (EMA); and
3. Submission of water plans for review and approval by Nolensv ille/College Grove
Utility District.
The Final Plat must address the following:
1. Prior to consideration of Final Plat approval, the applicant shall submit HOA
documents for review and approval by the County Attorney’s office. The HOA
documents must be submitted with the Final Plat, and the approved HOA
documents must be recorded concurrently with the recording of the Final Plat;
Item 25—Page 3 of 3
Reviewer: JYJ
Date: 5/14/2026
2. Establishment of a Performance Bond for roads, drainage and erosion control;
3. Prior to submittal of the first Final Plat, the required Zoning Certificate for the
wastewater treatment and disposal system shall be submitted, and all conditions
associated with the wastewater site plan appr oval must be satisfied;
4. Establishment of a P erformance Bond for water improvements in favor of
Nolensville/College Grove Utility District;
5. Per the recommendation of the County’s Wastewater Consultant, establishment of
a Performance Bond for the Treatment and Disposal System and the Wastewater
Collection System;
6. Prior to the issuance of building per mits within the associated Section of the
development in which the greenway located along Wilson Branch is within, the
paved greenway trail shall be constructed;
7. Submission of landscaping plans and establishment of a Performance Bond for
landscaping;
8. Dedication of right -of-way of twenty-five (25) feet off the centerline of Old
Murfreesboro Road;
9. Execution of Performance Agreements for the above referenced sureties;
10. Execution of a Stormwater Maintenance Agreement and submission of an
Operation and Maintenance Plan for stormwater improvements; and
11. Submission of the approved Final Plat in .dwg format on recordable media based
on the Tennessee State Plane Coordinate System prior to signature and recording
of the plat.
C0.0
COVER SHEET
WILSON BRANCH FARMS SUBDIVISION
OLD MURFREESBORO ROAD, WILLIAMSON COUNTY, TN
LOCATION MAP
SCALE: 1" = 2,000'
PROJECT
SITE
CONCEPT PLAN
N
FLOOD NOTE:
THERE IS NO PORTION OF THE SUBJECT
PROPERTIES THAT LIES WITHIN THE 100 YEAR
FLOODPLAIN BASED ON FEMA PANEL
47187C0385G DATED 12/20/2024.
GENERAL
INFORMATION
DEVELOPER
Contact: Brandon Jenkins
Email: brandon@grovepark.com
CIVIL ENGINEER
Crunk Engineering LLC
7112 Crossroads Boulevard, Suite 201
Brentwood, TN 37027
Contact: Will Crunk, PE
Phone: 615.873.1795
Email: will@crunkeng.com
SURVEYOR
Contact: Roger Harrah
Email: rharrah@twm-inc.com
Phone: 615-814-7414
UTILITIES
WATER: NOLENSVILLE/COLLEGE GROVE UTILITY DISTRICT
615-776-2511
2002 JOHNSON INDUSTRIAL BLVD.
NOLENSVILLE, TN 37135
SANITARY SEWER: SUPERIOR WASTEWATER SYSTEMS, LLC
615-834-1222
9539 MULLENS ROAD
ARRINGTON, TN 37014
ELECTRIC: MIDDLE TENNESSEE ELECTRIC
2156 EDWARD CURD LANE
FRANKLIN, TN 37067
GAS: ATMOS ENERGY
810 CRESCENT CENTRE DRIVE, SUITE 600
FRANKLIN, TN 37067
NATURAL GAS NOTE:
DEVELOPER TO NOTIFY THE OPERATOR OF THE
NATURAL GAS TRANSMISSION PIPELINE AS
REQUIRED BY TCA 13-3-414.
05/05/202625051
REVISIONS
No. DATE WILSON BRANCH FARMS SUBDIVISION
CONCEPT PLAN
OLD MURFREESBORO ROAD,
WILLIAMSON COUNTY, TENNESSEE
7112 CROSSROADS BOULEVARD
SUITE 201
BRENTWOOD, TN 37027
(615) 873-1795
WWW.CRUNKENG.COM
CRUNK ENGINEERING LLC
Drawing Path: P:\2025\25051 - 3036 Old Murfreesboro Rd\Dwg\Construction\C0.0-COV.dwg
WI LLIAM
W
. CRUNK
No. 115894
STATE OF
TENNESSEE
REGISTERED
ENGINEER
COMM
ERCE
AGRICULTURE
Sheet List Table
Sheet NumberSheet Title
C0.0COVER SHEET
C1.0EXISTING CONDITIONS
C2.0OVERALL SITE LAYOUT PLAN
C2.1DETAILED SITE LAYOUT PLAN
C2.2DETAILED SITE LAYOUT PLAN
C2.3LOT TABLE & TYPICAL LOT LAYOUT
C2.4OPEN SPACE PLAN
SUBJECT PROPERTY OWNERS
BETTY P. HOPKINS
MAP 113, PARCEL 40.00
BK. 3146, PG. 491
WILLIAM TROY HOPKINS
MAP 113, PARCEL 38.00
BK. 8980, PG 549
WILLIAM TROY HOPKINS
MAP 113, PARCEL 40.01
BK. 8980, PG. 544
ATTACHMENT 25-1A
N68° 06' 29"W
124.50'
N58° 24' 35"W
147.15'
S34°25'43"W 82.00'
N39°35'29"W 586.28'
N30° 01' 47"W
199.88'
N29° 53' 55"W
114.95'
N36° 08' 47"W
108.04' N34° 43' 47"E
200.54'
N28° 09' 52"E
107.96'
N31°29'06"W 109.59'
N43° 58' 37"E
130.19'
S89° 31' 02"E123.26'
S20°01'45"E 60.90'
S77° 00' 41"E154.94'
S77° 57' 21"E154.30'
N83°07'06"E 12.41'
N82°01'33"E 269.22'
N87°23'09"E 46.24'
S70°02'43"E 308.82'
S58° 06' 02"E157.54'S8°33'10"W 1319.63'
N36°27'08"W 195.96'
25' INGRESS, EGRESS & UTILITY EASEMENT
[R] S61°35'00"E 143.20'
[R] N82°45'00"W 327.00'[R] N17°15'00"W 74.00'
[R] N84°30'00"W 100.00'
[R] S30°30'00"W 104.00'
[R] S38°30'00"E 107.50'
S23°00'00"W 137.00'
[R] S30°15'00"W 200.50'
[R] S43°10'00"E 115.20'
[R] S34°00'00"E 314.40'
[R] S40°10'00"E 186.40'
[R] S45°00'00"E 597.00'
[R] N31°00'00"E 82.00'
[R] S75°10'00"E 124.50'
[R] N02°30'00"E 1307.00'
[R] N76°30'00"W 301.50'
[R] S85°30'00"W 57.00'
[R] S75°45'00"W 286.00'
[R] N62°15'00"W 158.00'
[TIE] N61° 15' 26"W
80.77'
DAVID & KRISTIE HARTMAN
TAX MAP 113 | PARCEL 39.01
D.B. 7210 - PG. 975
ROBERT & ANNE KIRK
TAX MAP 113 | PARCEL 37.00
D.B. 8994 - PG. 519
JACK S. SCHNEIDER
TAX MAP 113 | PARCEL 43.01
D.B. 9128 - PG. 808
JAMIE WILEE ET UX
TAX MAP 113 | PARCEL 41.00
D.B. 7045 - PG. 37
OLD MURFREESBORO ROAD
SEWER ESMTDB4967 PG746
50-FT WATERWAY
NATURAL AREA (WNA)
WET WEATHER CONVEYANCE
(WWC1)
WET WEATHER CONVEYANCE
(WWC2)
STREAM 1
STREAM 1
STREAM 1
STREAM 1
50-FT WATERWAY
NATURAL AREA (WNA)
STREAM 2
50-FT WATERWAY
NATURAL AREA (WNA)
WETLAND AREA
(WET_1)
UPLAND AREA
(UP_1)
SPRING
N22° 31' 13"E
243.52
N57° 32' 50"W210.20
S26° 18' 31"W259.00
OPEN SPACE
A = 15.08 ACRE
LOT: 13
AREA : 23,361 S.F.
LOT: 15
AREA : 25,153 S.F.
LOT: 16
AREA : 24,538 S.F.
LOT: 17
AREA : 24,884 S.F.
LOT: 18
AREA : 24,205 S.F.
LOT: 19
AREA : 24,175 S.F.
LOT: 20
AREA : 27,416 S.F.
LOT: 21
AREA : 29,578 S.F.
LOT: 22
AREA : 22,509 S.F.
LOT: 23
AREA : 22,491 S.F.
LOT: 24
AREA : 22,557 S.F.
LOT: 25
AREA : 22,301 S.F.
LOT: 26
AREA : 22,131 S.F.
LOT: 27
AREA : 29,913 S.F.
LOT: 28
AREA : 33,927 S.F.
LOT: 14
AREA : 24,001 S.F.
LOT: 5
AREA : 23,027 S.F.
LOT: 12
AREA : 23,345 S.F.
LOT: 11
AREA : 23,095 S.F.
LOT: 10
AREA : 31,931 S.F.
LOT: 9
AREA : 22,586 S.F.
LOT: 1
AREA : 23,832 S.F.
LOT: 2
AREA : 23,156 S.F.
LOT: 8
AREA : 22,532 S.F.
LOT: 7
AREA : 23,035 S.F.
LOT: 6
AREA : 22,902 S.F.
LOT: 4
AREA : 23,026 S.F.
LOT: 3
AREA : 23,025 S.F.
RESOURCE PROTECTION NOTE:
THIS SITE HAS BEEN REVIEWED FOR THE PRESENCE OF STEEP SLOPES, HILLTOPS
AND RIDGETOPS, SLIPPAGE SOILS, SPECIAL FLOOD HAZARDS, HISTORICAL AND
CULTURAL RESOURCES, AND KARST FEATURES. AREAS FALLING WITHIN THESE
CATEGORIES, IF ANY, HAVE BEEN NOTED ON THE PLAN AND CAN BE FOUND
ON THE NATURAL RESOURCE PROTECTION PLAN. THERE ARE NO HILLTOPS OR
RIDGETOPS IN THESE LOTS. THERE ARE NO SLIPPAGE SOILS INDICATED ON THE
PROPERTY BY THE NRCS WEB SOIL SURVEY. THERE ARE NO HISTORICAL OR
CULTURAL RESOURCES KNOWN ON THE PROPERTY.
05/05/202625051
REVISIONS
No. DATE WILSON BRANCH FARMS SUBDIVISION
CONCEPT PLAN
OLD MURFREESBORO ROAD,
WILLIAMSON COUNTY, TENNESSEE
7112 CROSSROADS BOULEVARD
SUITE 201
BRENTWOOD, TN 37027
(615) 873-1795
WWW.CRUNKENG.COM
CRUNK ENGINEERING LLC
Drawing Path: P:\2025\25051 - 3036 Old Murfreesboro Rd\Dwg\Construction\C2.0-LAY.dwg
WI LLIAM
W
. CRUNK
No. 115894
STATE OF
TENNESSEE
REGISTERED
ENGINEER
COMM
ERCE
AGRICULTURE
C2.0
OVERALL SITE
LAYOUT PLAN
NOTES:
1.REFER TO SHEET C2.3 FOR TYPICAL LOT LAYOUTS.
2.REFER TO SHEET C2.3 FOR LOT TABLES.
3.THIS PROPERTY HAS BEEN REVIEWED FOR THE EXISTENCE OF
INTERMITTENT AND PERENNIAL STREAMS. STREAMS THAT WOULD REQUIRE
WATERWAY NATURAL AREAS (WNA) AS DESCRIBED IN SECTION 4 OF THE
WILLIAMSON COUNTY STORM WATER MANAGEMENT REGULATIONS
HAVE BEEN LOCATED AS SHOWN.
4.WITHIN THE WATERWAY NATURAL AREA (WNA), THERE SHALL BE NO
CLEARING, GRADING, CONSTRUCTION, OR DISTURBANCE OF
VEGETATION EXCEPT AS PERMITTED BY THE WILLIAMSON COUNTY
ENGINEERING DEPARTMENT.
N
0
GRAPHIC SCALE
100200 50
1"=100'
CONCEPT PLAN
BOUNDARY
APPROXIMATE PATH OF 12' COMMUNITY
GREENWAY TRAIL WITH 15' EASEMENT (TYP)
CONCEPT PLAN
BOUNDARY
XX ROAD (PUBLIC DRIVE)
YY ROAD (PUBLIC DRIVE)
50 FT
OPEN SPACEBUFFER
50 FTOPEN SPACE
BUFFER
50 FT
WATERWAY NATURAL
AREA (WNA)
CRITICAL LOTS:
PROPOSED SINGLE FAMILY LOTS THAT HAVE
EXISTING CRITICAL SLOPES ARE INDICATED WITH
THIS SYMBOL. AN ENGINEERED SITE PLAN SHALL
BE SUBMITTED AND APPROVED BY WILLIAMSON
COUNTY ENGINEERING DEPARTMENT.
LOTS CURRENTLY CONTAIN CRITICAL SLOPES
WITH THE EXISTING TOPOGRAPHY ARE AS
FOLLOWS:
8, 20, 21, 22, 23, 24, 25, 26, AND 28.
ALL VERY STEEP SLOPES THAT ARE 5,000 SQUARE
FEET OR GREATER IN AREA ARE CONTAINED
WITHIN OPEN SPACE AREAS.
*
*
*
*
*
*
*
**
*
50 FTOPEN SPACE
BUFFER
PROPOSED WNA DISTURBANCE
8,450 SQ-FT / 0.19 AC
25 FTROW DEDICATION
TYPICAL GREENWAY TRAIL
STREAM CROSSING
TYPICAL GREENWAY TRAIL
STREAM CROSSING
APPROXIMATE PATH OF COMMUNITY
TRAIL WITH ROW ACCESS (TYP)
40 FTROW
15 FTPUD&AE
15 FTPUD&AE
APPROXIMATE PATH OF 12' COMMUNITY
GREENWAY TRAIL WITH 15' EASEMENT (TYP)
APPROXIMATE PATH OF 12' COMMUNITY
GREENWAY TRAIL WITH 15' EASEMENT (TYP)
APPROXIMATE LOCATION OF 15' GREENWAY
TRAIL EASEMENT FOR FUTURE CONNECTION
15 FT
15 FT
TRAIL ACCESS EASEMENT
12 FT
GREENWAY TRAIL
12 FTGREENWAY TRAIL
15 FT
TRAIL ACCESS EASEMENT
25 FTTRAIL ACCESS EASEMENT
25 FT
TRAIL ACCESS EASEMENT
25 FTTRAIL ACCESS EASEMENT
15 FTPUD&AE 15 FTPUD&AE
ATTACHMENT 25-1B
ATTACHMENT 25-2
Item 26—Page 1 of 2
Reviewer: OCW
Date: 5-14-2026
ITEM 26
PRELIMINARY PLAT REVIEW FOR CHESTNUT HIL L FARMS LLE SUBDIVIS ION,
CONTAINING 5 LOTS ON 28.50 ACRES LOCATED OFF WHIPPOORWILL DR IVE
IN THE 1ST VOTING DISTRICT (1-2025-324).
Attachment 26-1 Preliminary Plat
26-2 Aerial Photography
Area 28.50 acres
Lots 5
Zoning Municipal Growth Area–1 (MGA-1)
Water On-Site Wells
Sewer Individual On-Site Septic Systems
Development Option Large Lot Easement Subdivision
Chapter 1101 Status City of Fairview Urban Growth Boundary
File Number (1-2025-324)
The subject parcel is approximately twenty-eight (28) acres in size and is located off
Whippoorwill Drive , which is located in Cheatham County . The applicant is requesting
approval of a Large Lot Easement Subdivision in order to create five (5) lots off a new
ingress/egress/utilities easement. Cheatham County has approved the connection.
The site contains natural resources requiring protection, including wetlands and waterway
natural areas. All Zoning Ordinance requirements, including those regarding the
protection of natural resources, have been met.
The applicant is proposing individual septic systems for the lots, and the Williamson
County Department of Sewage Disposal Management has approved the reques t. As no
public water is available, water will be provided by on -site wells. As no fire hydrants are
proposed, building envelopes have been separated by 200 feet, and the fire apparatus
access requirements in Sec tion 3.05 (B) (2) (b) (ii) in the Subdivision Regulations must
be met.
The Preliminary Plat is in order and Staff recommends approval, subject to the following
conditions, which must be addressed in conjunction with Final Plat submittal:
1. A Land Disturbance Permit must be obtained for the overall development;
2. A Notice of Coverage issued by TDEC will be required prior to the issuance of a
Land Disturbance Permit;
Item 26---Page 2 of 2
Reviewer: OCW
Date: 5-14-2026
3. Prior to submittal of the Final Plat, driveway and drainage infrastructure must be
complete, consistent with Zoning Ordinance requirements; and
4. Satisfaction of Section 3.05 of the Subdivision Regulations, as it pertains to fire
apparatus access requirements.
ATTACHMENT 26-1A
ATTACHMENT 26-1B
ATTACHMENT 26-2
Item 27—Page 1 of 2
Reviewer: OCW
Date: 5-14-2026
ITEM 27
PRELIMINARY PLAT REVIEW FOR JOYBELLE ESTATES SUBDIVISION,
CONTAINING 12 LOTS ON 110.1 ACRES LOCATED OFF EUDAILEY-COVINGTON
ROAD IN THE 2ND VOTING DISTRICT (1-2026-304).
Attachment 27-1 Preliminary Plat
27-2 Aerial Photograph
Area 110.1 acres
Lots 12
Zoning Rural Development–5 (RD-5)
Water Milcrofton Utility District
Sewer Individual On-Site Septic
Development Option Major Traditional Subdivision
Chapter 1101 Status Rural
Map and Parcel 141---051.00
File Number (1-2026-304)
A Concept Plan for this development was approved by this body at the November 2025
meeting. The applicant is now requesting Preliminary Plat approval for the development,
which contains twelve (12) lots and approximately 14.21 acres of Open Space. The plat
is consistent in layout with the revised Concept Plan.
Staff recommends approval of the Preliminary Plat with the following conditions, which
must be addressed in conjunction with the Final Plat submittal:
1. Prior to consideration of Final Plat approval, the applicant shall submit HOA
documents for review and approval by the County Attorney’s office. The HOA
documents shall address the requirements of Section 17.12: Private Streets of the
Zoning Ordinance. The HOA documents must be submitted with the Final Plat,
and the approved HOA documents must be recorded concurrently with the
recording of the Final Plat;
2. A permit for the security gate will need to be obtained prior to its installation, and
all requirements for such gates as outlined in Section 17.11 of the Zoning
Ordinance must be met;
3. Establishment of a performance bond for roads, drainage and erosion control;
4. Establishment of a performance bond for water impro vements in favor of
Milcrofton Utility District;
Item 27---Page 2 of 2
Reviewer: OCW
Date: 5-14-2026
5. Submission of landscaping plans and establishment of a performance bond for
landscaping improvements;
6. Dedication of right -of-way twenty -five (25) feet off the centerline of Eudailey-
Covington Road;
7. Execution of Performance Agreements for the above-referenced sureties;
8. Execution of a Stormwater Maintenance Agreement and submission of an
Operation and Maintenance Plan for stormwater improvements; and
9. Submission of the approved Final Plat in .dwg format on reco rdable media based
on the Tennessee State Plane Coordinate System prior to signature and recording
of the plat.
GAS
GAS
GAS
GAS
GAS
GAS
W
W
W
W
W
W
W
W
S7°43'57"W 939.92'
ROW DEDICATION:
14,588.54 SQ. FT.
TENNESSEE SOCCER
CLUB, INC.
MAP 142 PARCEL 15.04
BOOK 9642, PAGE 669
BOLTON REV LIV TRUST
MAP 141 PARCEL 52.02
BOOK 9360, PAGE 129STEPHEN & ALEXANDRA
KARPENKO
MAP 141 PARCEL 52.03
BOOK 9208, PAGE 217
GREGORY & MARY STONE
MAP 141 PARCEL 52.06
BOOK 6175, PAGE 863
JONATHAN & MONA HOLT
MAP 141 PARCEL 52.04
BOOK 6162, PAGE 30
WILLIAM PATRICK &SHARON THOMPSON REV
TRUST
MAP 141 PARCEL 52.07
BOOK 9377, PAGE 218
LOOPE FAMILY TRUST
MAP 141 PARCEL 52.05
BOOK 9289, PAGE 561
MILLER CULBERSON
MAP 158 PARCEL 1.00
BOOK 5011, PAGE 487
ROSEMARY SHEARER
NOLEN ETAL
MAP 157 PARCEL 26.04
BOOK 6335, PAGE 466
TRACT 1
L66
50' ROW
50' ROW
50' ROW
50' ROW
60' ROW
EUDAILEY COVINGTON RD
TENNESSEE SOCCER
CLUB, INC.
MAP 142 PARCEL 15.04
BOOK 9642, PAGE 669
JOYBELLE LANE
(50' PRIVATE)
12
3
10
4
11
5
6
O.S. 1
7
8
1
2
9
O.S. 2
JOYBELLE LANE(50' PRIVATE)
S80°21'00"E 503.62'
S9°40'54"W
1352.83'
S1°13'03"E 728.22'S26°21'50"E 343.73'
S83°53'23"E 2122.41'
S12°25'28"W 630.18'
S79°59'32"E 542.73'
N1°29'37"W 540.39'N27°14'49"W 395.24'
N86°24'42"W 601.22'
N8°29'43"W 494.74'
N0°31'20"E 483.80'
S6°07'34"W 376.47'
S6°07'34"W 419.69'
S6°07'34"W 387.18'
N60°20'25"E 730.54'
N79°34'59"E 439.41'
S76°18'02"E 713.50'
S80°18'23"E 453.98'
S80°21'00"E 362.85'
L1
L2
L3
L4
L5
L6
L7L8
L9
L10
L11
L12L13
L14
L15L16
L17L18
L19L20
L21
L22
L23
L24
L25
L26
L27
L28
L29
L30
L31
L33 L32
L34
L35
L36
L37
L38
L39
L40
L41
L42
L43
L44 L45
L46L47
L48
L49
L50
L67
L68
L69
L70
L71
L72
L73
L74
L75
L76
L77
L78
L79
L80L81
L82
L83L84L85
L86
L87
L88
L89
L90
L91
L92
L93
L94
C1C2
L95L96
671.83'
C3
C4
L51
L100
L97
L99
N66°34'51"W 440.69'
L98
S9°54'18"W 380.53'
N9°54'18"E 380.97'
C24
C5
C6
C7C8
L52
L53
C9
C10
L54
C11L55L56C12
C13
C14
L57
L58
C15
C16
C17
C18
C19
L59
L60
C20 L61 L62 C21
L63
L64
C22
L65
C23
Parcel Area Table
Parcel #
1
2
3
4
5
6
7
8
9
10
11
12
Area (SF)
218044.98'
217917.21'
252458.23'
359760.76'
271647.74'
244558.67'
294610.08'
218099.70'
217592.25'
244068.25'
257605.30'
300732.37'
Area (AC)
5.01
5.00
5.80
8.26
6.24
5.61
6.76
5.01
5.00
5.60
5.91
6.90
Open Space Area Table
Parcel #
O.S. 1
O.S. 2
TRACT 1
Area (SF)
548599.14'
84233.65'
874173.31'
Area (AC)
12.59
1.93
20.07
Parcel Line Table
Line #
L1
L2
L3
L4
L5
L6
L7
L8
L9
L10
L11
L12
L13
L14
L15
L16
L17
L18
L19
L20
L21
L22
L23
L24
L25
L26
Length
79.92'
136.44'
207.30'
84.20'
302.27'
268.93'
342.59'
38.52'
32.14'
20.56'
50.22'
29.79'
79.94'
43.32'
31.42'
55.88'
34.98'
40.88'
33.89'
36.70'
34.81'
39.96'
46.68'
25.84'
31.65'
65.22'
Direction
N80°46'54"W
N80°21'00"W
N5°10'09"E
N19°47'52"E
N7°50'26"E
N7°46'49"E
N7°47'25"E
S88°06'49"W
S67°11'28"W
S81°39'23"W
N79°56'51"W
N85°33'56"W
N83°03'34"W
N83°42'14"W
N78°49'01"W
N86°52'07"W
N82°02'52"W
N85°30'02"W
N68°06'02"W
N75°21'53"W
N52°28'48"W
N57°52'11"W
N61°37'31"W
N77°46'06"W
N50°11'29"W
N57°18'11"W
Parcel Line Table
Line #
L27
L28
L29
L30
L31
L32
L33
L34
L35
L36
L37
L38
L39
L40
L41
L42
L43
L44
L45
L46
L47
L48
L49
L50
L51
L52
Length
36.74'
20.08'
31.12'
22.00'
50.36'
22.27'
37.53'
14.25'
18.11'
18.93'
50.29'
43.79'
95.12'
56.92'
16.32'
50.83'
18.22'
34.17'
15.13'
32.81'
33.78'
62.46'
67.48'
38.69'
25.00'
174.13'
Direction
N42°44'23"W
N26°32'04"W
N31°46'30"W
N51°30'09"W
N70°58'18"W
N40°11'12"W
N18°14'58"W
S84°57'16"W
S48°37'10"W
N65°38'15"W
N47°03'44"W
N38°50'34"W
N42°39'08"E
N55°06'40"E
S76°35'32"E
S84°29'33"E
N66°27'55"E
N28°47'43"E
N27°48'16"W
N13°44'14"W
N45°13'53"W
N30°31'11"W
S79°42'57"E
S79°42'57"E
S9°40'54"W
S29°33'33"E
Parcel Line Table
Line #
L53
L54
L55
L56
L57
L58
L59
L60
L61
L62
L63
L64
L65
L66
L67
L68
L69
L70
L71
L72
L73
L74
L75
L76
L77
L78
Length
173.90'
265.66'
292.05'
100.49'
175.87'
448.54'
352.35'
272.06'
103.58'
288.96'
225.46'
40.20'
348.04'
25.00'
313.79'
130.78'
366.22'
65.09'
448.30'
166.28'
116.85'
235.42'
467.44'
210.47'
420.78'
130.51'
Direction
S29°33'33"E
S22°13'27"W
S1°54'44"W
S1°54'44"W
S82°59'42"E
S82°59'42"E
N82°59'42"W
N82°59'42"W
N1°54'44"E
N1°54'44"E
N22°13'27"E
N22°13'27"E
N29°33'33"W
N9°39'00"E
N38°33'32"W
N5°26'31"W
N82°12'20"W
S80°46'54"E
N9°40'54"E
N80°18'23"W
N16°19'59"W
N82°09'15"W
N9°40'54"E
N79°26'21"E
N9°40'54"E
N87°40'16"W
Parcel Line Table
Line #
L79
L80
L81
L82
L83
L84
L85
L86
L87
L88
L89
L90
L91
L92
L93
L94
L95
L96
L97
L98
L99
L100
Length
209.68'
176.10'
138.80'
401.80'
324.46'
398.99'
150.98'
175.88'
194.69'
398.06'
220.64'
663.18'
140.27'
497.35'
527.12'
54.93'
440.83'
23.79'
63.53'
100.00'
340.00'
80.02'
Direction
S80°26'54"W
S13°13'20"E
S82°16'53"W
N84°09'39"W
N1°13'03"W
N1°13'03"W
N26°21'50"W
S87°54'00"E
N26°21'50"W
N12°25'28"E
N12°25'28"E
N83°53'23"W
S40°10'14"W
N83°53'23"W
N83°53'23"W
S6°07'34"W
N83°53'23"W
N35°23'12"W
N80°21'00"W
N80°21'00"W
N80°21'00"W
N80°46'54"W
Curve Table
Curve #
C1
C2
C3
C4
C5
C6
C7
C8
C9
C10
C11
C12
C13
C14
C15
C16
C17
C18
C19
C20
C21
C22
C23
C24
Length
148.67'
35.30'
154.41'
74.22'
28.98'
10.40'
158.44'
185.95'
149.59'
189.33'
150.36'
178.30'
191.40'
260.12'
37.85'
51.38'
188.50'
49.55'
37.85'
555.72'
132.94'
384.11'
309.95'
39.16'
Radius
694.00'
100.00'
168.00'
250.00'
25.00'
25.00'
500.00'
500.00'
375.00'
375.00'
425.00'
425.00'
425.00'
425.00'
45.00'
60.00'
60.00'
60.00'
45.00'
375.00'
375.00'
425.00'
450.00'
25.00'
Delta
12° 16' 28"
20° 13' 40"
52° 39' 33"
17° 00' 33"
66° 25' 19"
23° 49' 59"
18° 09' 19"
21° 18' 31"
22° 51' 21"
28° 55' 39"
20° 16' 15"
24° 02' 12"
25° 48' 10"
35° 04' 05"
48° 11' 15"
49° 03' 59"
180° 00' 00"
47° 18' 47"
48° 11' 31"
84° 54' 26"
20° 18' 43"
51° 47' 00"
39° 27' 51"
89° 44' 42"
Chord Direction
N73° 51' 18"W
N57° 36' 14"W
N21° 09' 37"W
N3° 20' 07"W
S47° 08' 21"E
S2° 00' 42"E
S0° 49' 38"W
S18° 54' 17"E
S18° 07' 52"E
S7° 45' 38"W
S12° 05' 20"W
S10° 06' 22"E
S35° 01' 33"E
S65° 27' 40"E
S58° 54' 05"E
S59° 20' 26"E
N6° 07' 34"E
S72° 28' 11"W
S72° 54' 33"W
N40° 32' 29"W
N12° 04' 06"E
N3° 40' 03"W
N9° 49' 37"W
N54° 46' 39"E
Chord Length
148.39'
35.12'
149.03'
73.94'
27.39'
10.32'
157.77'
184.88'
148.60'
187.33'
775.39'
176.99'
189.78'
256.08'
36.74'
49.83'
120.00'
48.15'
36.74'
506.24'
132.25'
371.17'
303.86'
35.28'
PROJECT NAME
PROJECT NUMBER
ADDRESS
PARCEL ID
EXISTING ZONING
PROPOSED ZONING
EXISTING SITE AREA
PROPOSED SITE AREA
PROPOSED ROW
ROW DEDICATION
PROPOSED LOTS
MAXIMUM GROSS DENSITY
PROPOSED DENSITY
MINIMUM LOT AREA
MINIMUM LOT WIDTH
JOYBELLE ESTATE
25-2423
6615 EUDAILEY-COVINGTON ROAD
MAP 141 - PARCEL 51.00
RD-5
RD-5
110.1 ACRES
90.1
4.3 ACRES
0.33 ACRES
12
1 LOT / 5 ACRES
0.67 LOTS / 5 ACRES
5 ACRES
200'
SITE DATA
SETBACKS
FRONT
SIDE
REAR
100'
25'
50'
RESOURCE PROTECTION
REQUIRED OPEN SPACE
PROPOSED OPEN SPACE
REQ. TREE CANOPY RET.
PRO. TREE CANOPY RET.
WETLANDS
ISOLATED WETLANDS REMOVAL
15% (13.51 ACRES)
16% (14.21 ACRES)
69% (16.35 ACRES)
96% (22.7 ACRES)
6.3 ACRES
1.87 ACRES
IRON PIN FOUND
IRON PIN SET
CONC. MON. FOUND
CONC. MON. SET
CONTROL POINT FOUND
CONTROL POINT SET
BENCH MARK
WATER METER
WATER VALVE
LEGEND
FIRE HYDRANT
SANITARY SEWER MH
SANITARY SEWER CO
AREA DRAIN
CURB INLET
STORM MH
ELECTRIC METER-BOX
ELECTRIC MH
LIGHT POLE
UTILITY POLE
GUY ANCHOR
COMMUNICATION BOX
COMMUNICATION MH
GAS METER
GAS VALVE
EVERGREEN TREE
SIDEWALK
MIN. BUIDLING SETBACK
M.B.S.L
PUBLIC UTIL. & DRAIN ESMT. P.U.D.E.
ADDRESSES1234
HANDICAP SPACE
SANITARY SEWER
WATER
UNDERGROUND ELEC
OVERHEAD ELEC
GAS
COMMUNICATIONS
8" SA
4" W
UGE
OHE
BOUNDARY
CENTERLINE
FENCE
WATER FEATURE
TREE LINE
4" G
COM
X
NO. DATE COMMENT
108 Beasley Drive
Franklin, TN
37064
615.794.2275
1 3/16/26 COMMENTS FROM COUNTY
2 3/30/26 WILCO ENGINEERING COMMENTS
3 4/24/26 WILCO ENGINEERING COMMENTS
JOYBELLE ESTATES
6615 EUDAILEY-COVINGTON ROAD
MAP 141 - PARCEL 51.00
WILLIAMSON COUNTY, COLLEGE GROVE, TENNESSEE
C2.3 PRELIMINARY PLAT - OVERALL
1000 N 537029.002 E 1756686.710 EL 863.88 RBCS OFFSITE
1001 N 536716.511 E 1757725.202 EL 827.18 RBCS TARGET
1002 N 535430.990 E 1757655.635 EL 813.80 RBCS TARGET
1003 N 534140.561 E 1757526.131 EL 747.94 RBCS TARGET
1004 N 533967.946 E 1759463.113 EL 740.78 RBCS TARGET
1005 N 533815.177 E 1760083.392 EL 727.59 RBCS TARGET
1006 N 533602.866 E 1759962.032 EL 727.51 RBCS TARGET
1007 N 536353.646 E 1759817.119 EL 787.63 RBCS OFFSITE
1008 N 534229.638 E 1761479.336 EL 724.06 RBCS OFFSITE
1010 N 531385.320 E 1757454.980 EL 755.37 RBCS OFFSITE
1011 N 533567.799 E 1756255.824 EL 775.09 RBCS OFFSITE
1012 N 535139.591 E 1756659.797 EL 775.84 RBCS OFFSITE
PROJECT CONTROL: TENNESSEE STATE PLANE COORDINATES.
NAD83, GEOID 03 ZONE 7 REVISED. NO DATUM ADJUSTMENT.
CONTROL TABLE
GRAPHIC SCALE 1:200
400' 200' 0' 200' VICINITY MAP
NOT TO SCALE
SITE
PLAT NOTES
1. THE PURPOSE OF THIS PLAT IS TO CREATE 12 LOTS FOR
FUTURE DEVELOPMENT, 2 OPEN SPACES, AND 1 TRACT.
2. SUBJECT PROPERTY IS PRESENTLY IDENTIFIED AS ALL OF
PARCEL 51.00 , ON WILLIAMSON COUNTY TAX MAP 141.
SAID PARCELS ARE FURTHER IDENTIFIED AS THE
PROPERTY DESCRIBED IN DEED BOOK 7940, PAGE 377,
REGISTERS OFFICE OF WILLIAMSON COUNTY, TENNESSEE
3. ZONING: RD-5 (RURAL DEVELOPMENT - 5)
4. BEARINGS AND COORDINATES SHOWN HEREON ARE
BASED ON THE TENNESSEE STATE PLANE COORDINATE
SYSTEM NAD83 (2011 US SURVEY FEET). ELEVATIONS
SHOWN HEREON ARE BASED ON NAVD88.
5. BY SCALED MAP LOCATION AND GRAPHIC PLOTTING ONLY,
THIS PROPERTY LIES WITHIN ZONE “X” AS DESIGNATED ON
CURRENT FEDERAL EMERGENCY MANAGEMENT AGENCY
MAP NO. 47187C0390G, WITH AN EFFECTIVE DATE OF
DECEMBER 20, 2024, WHICH MAKES UP A PART OF THE
NATIONAL FLOOD INSURANCE PROGRAM. ZONE “X” IS AN
AREA DETERMINED TO BE OUTSIDE THE 0.2% ANNUAL
CHANCE FLOODPLAIN.
6. I HEREBY CERTIFY THAT THIS IS A CATEGORY IV SURVEY
AND WAS CONDUCTED IN ACCORDANCE WITH RULE
0820-03.11 (GLOBAL POSITION SYSTEMS SURVEYS)
ACCORDING TO THE CURRENT TENNESSEE MINIMUM
STANDARDS OF PRACTICE AS PROMULGATED BY THE
TENNESSEE STATE BOARD OF EXAMINERS FOR LAND
SURVEYORS. THIS SURVEY WAS CONDUCTED WITH
DUAL-FREQUENCY RTK GPS EQUIPMENT BASED ON THE
TDOT CORPS NETWORK.
a. POSITIONAL ACCURACY: 0.07'
b. DATE OF SURVEY: 10/20/08
c. DATUM/EPOCH: TENNESSEE STATE PLANE NAD83
(2011 US SURVEY FEET). OCCUPATIONS FOR
CONTROL POINTS ARE 3 MINUTES EACH, SIDE SHOTS
ARE 3 SECONDS.
d. GEOID 3, ZONE 7 REVISED
e. NO COMBINED GRID FACTORS WERE USED.
7. ALL CORNERS SHOWN ON THE FACE OF THE SURVEY WILL
BE SET WITH 5/8 IRON ROD WITH CAP BEARING THIS
SURVEYORS COMPANY NAME.
8. MAINTENANCE OF ALL STORMWATER MANAGEMENT
FEATURES SHALL BE THE RESPONSIBILITY OF THE
PROPERTY OWNER(S) OR THE HOA.
9. NO OBSTRUCTIONS OR ENCROACHMENTS WHICH IMPEDE
THE FLOW OF STORMWATER SHALL BE PERMITTED WITHIN
PUBLIC DRAINAGE EASEMENTS. WILLIAMSON COUNTY IS
NOT RESPONSIBLE FOR REPAIR OR REPLACEMENT OF
ANY ENCROACHMENTS THAT ARE DAMAGED OR REMOVED
IN THE COURSE OF MAINTENANCE ACTIVITY WITHIN
EASEMENTS.
10. WITHIN THE WATERWAY NATURAL AREA, THERE SHALL BE
NO CLEARING, GRADING, CONSTRUCTION OR
DISTURBANCE OF VEGETATION EXCEPT AS PERMITTED BY
THE WILLIAMSON COUNTY ENGINEERING DEPARTMENT.
11. THIS SITE HAS BEEN REVIEWED FOR THE PRESENCE OF
STEEP SLOPES, HILLTOPS AND RIDGETOPS, SLIPPAGE
SOILS, AND KARST FEATURES. BUILDING AREAS FOR LOTS
1, 2, AND 3 HAVE BEEN IDENTIFIED AS HAVING STEEP
SLOPES.
12. THIS PROPERTY HAS BEEN REVIEWED FOR THE
EXISTENCE OF INTERMITTENT AND PERENNIAL STREAMS.
STREAMS THAT WOULD REQUIRE A WATERWAY NATURAL
AREA AS DESCRIBED IN SECTION 4 OF THE WILLIAMSON
COUNTY STORM WATER MANAGEMENT REGULATIONS
HAVE BEEN LOCATED AS SHOWN.
13.NO PORTION OF THIS PROPERTY IS LOCATED IN AN AREA
DESIGNATED AS A 100 YEAR FLOOD ZONE AS EVIDENCED ON
FEMA PANEL #47187C0390G OF WILLIAMSON COUNTY, TN, DATED
12/20/2024.
14.SOIL MAP REASSESSMENT WAS APPROVED BY WILLIAMSON
COUNTY SEWER DEPARTMENT ON 2/23/26.
ROW DEDICATION
WNA 50' FROM TOP OF BANK
HATCH LEGEND
4/24/2026
ATTACHMENT 27-1
ATTACHMENT 27-2
Item 28—Page 1 of 2
Reviewer: LS
Date: 5-14-2026
ITEM 28
PRELIMINARY PLAT REVIEW FOR CREEKBEND MANOR (AKA 8828 HORTON
HIGHWAY) LARGE LOT EASEMENT SUBDIVISION , CONTAINING 5 LOTS ON
28.01 ACRES LOCATED OFF HORTON HIGHWAY IN THE 2ND VOTING DISTRICT
(1-2025-334)
Attachment 28-1 Preliminary Plat
28-2 Aerial Photograph
28-3 Variance Request for Flood Plain Disturbance
28-4 Variance Request for Easement Setback Encroachment
Area 28.01 acres
Zoning College Grove Village (CGV)
Lots 5
Water Nolensville/College Grove Utility District
Sewer Individual On-Site Septic Systems
Development Option Large Lot Easement
Chapter 1101 Status Rural
Map and Parcel 158---04302
File Number (1-2025-334)
The subject parcel is 28.01 acres in size and is located off Horton Highway. The applicant
is requesting approval of a Large Lot Easement Subdivision in order to create five (5) lots
off a new fifty-foot (50’) ingress/egress/utilities easement.
The site contains natural resources requiring protection, including steep slopes, 100-year
flood plain, Waterway Natural Areas (WNAs), and tree canopy. All Zoning Ordinance
requirements, including those regarding the protection of natural resources, have been
met.
The applicant is proposing individual on-site septic systems for the lots, and the
Williamson County Department of Sewage Disposal Management has approved the
request. Water will be provided by the Nolensville/College Grove Utility District. As no
fire hydrants are proposed, building envelopes have been separated by 200 feet as
required in Section 3.05 (B) (2) (b) (i) of the Subdivision Regulations , and fire sprinkler
systems shall be provided in all habitable structures.
The lots in question will take access from an existing fifty -foot (50’) easement that
extends from Horton Highway across the floodplain and one (1) other property. In order
for the easement to transverse the floodplain and to construct the necessary bridge to
cross Overall Creek, a Floodplain Development Permit (FDP) is required. The FDP has
been submitted and is under review by the Engineering Department. Section 3.04 (D) of
Item 28—Page 2 of 2
Reviewer: LS
Date: 5-14-2026
the Subdivision Regulations prohibits buildings or structures within floodplain, and as
such, a variance from this requirement is needed in order for the Engineering Department
to approve and issue the FDP. The Engineering Department supports the variance
request.
The existing easement was created in 2025 and does not meet the minimum separation
requirement of five (5) feet . Section 3.02 (D)(2)(b) of the Subdivision Regulations
requires all access easements be set back a minimum of five (5) feet from adjacent
parcels that will not access the easement. The applicant is requesting a variance from
this Section so as not to be required to relocate the easement to meet the five (5) foot
setback requirement from adjacent parcels that do not access the easement (See
Attachment 28-4). Because the easement was created in 2025 and the five (5) foot
setback was required from adjoining properties at the time, Staff does not support the
variance request.
The Preliminary Plat is in order , and so long as the Planning Commission grants the
requested v ariances, Staff recommends approval, subject to the following conditions,
which must be addressed in conjunction with Final Plat submittal:
1. A Notice of Coverage issued by TDEC will be required prior to the issuance of a
Land Disturbance Permit;
2. Satisfaction of Section 3.05 of the Subdivision Regulations, as it pertains to fire
sprinkler systems in habitable structures on all lots;
3. Establishment of a Performance Bond for water improvements in favor of
Nolensville/College Grove Utility District;
4. Submission of road names for review and approval by the Williamson County
Emergency Management Agency (EMA);
5. A Land Disturbance Permit must be obtained for the overall development; and
6. Prior to submittal of the Final Plat, driveway and drainage infrastructure must be
complete, consistent with Zoning Ordinance requirements. The applicant shall
notify Staff in order to conduct the required inspection.
0 100 200 300
HOMELAND SURVEYING
& MAPPING, LLC
PRELIMINARY PLAT
OF
CREEKBEND MANOR
COLLEGE GROVE, TN. 37046
ti ati
ti
ti
ti
ti ti
ti
ti
ti
ti ti ti
ti
ti
ti ti
ti
ti ti ti
ti
ti ti ti
ti ti ti ti
ti ti
ti ti
’
’
T28
100 FT
W
ATERW
AY NATURAL AREA
50 FT
W
NA BUFFER
50 FT
WNA BUFFER
100 FT WATERWAY NATURAL
AREAWNA BUFFER
LOT 5 PRIMARY PRINCIPAL
SSDS AREA RESTRICTED TO
ONE 5 BEDROOM
CONVENTIONAL. LPP
BEDROOM COUNT TBD BY
FIELD LAYOUT
EGAM, OVERWASH WDD
75 MPI TO 24" - LPP
WDD TO 36"
0-5% SLOPES
9,825 SQFT. / 0.23 ACRES
10,005 SQFT. / 0.23 ACRES
LOT 1 PRIMARY PRINCIPAL
SSDS AREA RESTRICTED TO
ONE 5 BEDROOM
CONVENTIONAL. LPP
BEDROOM COUNT TBD BY
FIELD LAYOUT
EGAM, OVERWASH WDD
75 MPI TO 24" - LPP
WDD TO 36"
0-5% SLOPES
9,899 SQFT. / 0.23 ACRES
10,109 SQFT. / 0.23 ACRES
13,056 SQFT. / 0.30 ACRES
LOT 2 PRIMARY PRINCIPAL
SSDS AREA RESTRICTED TO
ONE 8 BEDROOM
CONVENTIONAL OR LPP
SYSTEM
MARSH
45 MPI TO 24" - LPP
5-15% SLOPES
14,024 SQFT. / 0.32 ACRES
LOT 3 PRIMARY PRINCIPAL
SSDS AREA RESTRICTED TO
ONE 5 BEDROOM 5 BEDROOM
CONVENTIONAL. LPP
BEDROOM COUNT TBD BY
FIELD LAYOUT
STIVERSVILLE
30 MPI TO 24" - LPP
5-15% SLOPES
7,322 SQFT. / 0.17 ACRES
6,556 SQFT. / 0.15 ACRES
LOT 4 PRIMARY PRINCIPAL SSDS
AREA RESTRICTED TO ONE 5
BEDROOM CONVENTIONAL.
LPP BEDROOM COUNT TBD BY
FIELD LAYOUT
STIVERSVILLE
30 MPI TO 24" - LPP
15-25% SLOPES
8,729 SQFT. / 0.20 ACRES
8,495 SQFT. / 0.20 ACRES
O12
L12
O9
Q9
R12
T12
Q11
S8
P8
N7
M10
O14
U30
T30T28
Q33
S32
R31
N28
L29 L31
I29
K28
J28J26J25
I24
L26
K25
L24
D
E
E
D
B
C
B
A
F
G
I
FG
H
A
K
C
H
J
I
J
CREEK BOUNDARY
CREEK BOUNDARY
●
●
●
●
●
ATTACHMENT 28-1
Item 29—Page 1 of 1
Reviewer: JYJ
Date: 5/14/2026
ITEM 29
SITE PLAN REVIEW FOR THE ARBORS AT LEIPERS FORK SUBDIVISION
AMENITY CENTER, ON 51.41 ACRES, LOCATED OFF HARGROVE ROAD IN THE
1ST VOTING DISTRICT (5-2026-002).
Attachments 29-1 Site Plan
29-2 Aerial Photograph
Area 51.41 acres
Zoning Rural Development–5 (RD-5)
Water HB & TS Utility District
Sewer Individual On-site Septic Systems
Development Options Private Recreational Center
Chapter 1101 Status Rural
Map and Parcels 094—038.17
File Number (5-2026-002)
The applicant is requesting Site Plan approval for an amenity center for the A rbors at
Leipers Fork subdivision, which will be located in Open Space and contains a sports court
with a pavilion, a small playground, a pavilion and fire pit, sidewalks, trails and a parking
lot. Natural Resource Protection standards have been met.
Pursuant to Section 11.03 (D)(8) of the Zoning Ordinance, this Site Plan must be reviewed
by the Planning Commission at a public meeting. Amenity Centers embedded within
residential neighborhoods and located within Open Space are classified as Private
Recreational Centers, which are intended for the exclusive use of the residents of the
subdivision.
The requirements of S ection 11.03 (D)(8) have been met. There will be no water or
sewer service to the amenity center, and therefore no water or sewer bond is required.
The Site Plan is in order, and Staff recommends approval with the condition that the HOA
documents shall be revised to be consistent with the requirements and limitations of the
Private Recreational Center Use Type as described by the Zoning Ordinance.
Cut Slope Layout Mode
Fill Slope Layout Mode
Cut Slope Layout Mode
Fill Slope Layout Mode
COVER SHEET
C-0.0
6201 MAYVIEW PASS
MAP 94, PARCEL 38.17
FOR
THE ARBORS AT LEIPERS FORK
Franklin, Williamson County, Tennessee
SITE PLAN
N.T.S.
LOCATION MAP
DEVELOPER: C.E. Crews Jr./CC Trust
5600 BOY SCOUT RD
FRANKLIN, TN 37064
ENGINEER: T-SQUARE ENGINEERING
111 SE PARKWAY CT
FRANKLIN, TN 37064
WATER UTILITY: HB&TS
505 DOWNS BLVD.
FRANKLIN, TN 37064
SURVEYOR: T-SQUARE ENGINEERING
111 SE PARKWAY CT
FRANKLIN, TN 37064
SITE
APPLICANT
T-SQUARE ENGINEERING
111 SE PARKWAY CT
FRANKLIN, TN 37064
615.678.8212
FLOOD NOTE
NO PORTION OF THIS PROPERTY IS LOCATED IN AN AREA DESIGNATED AS A 100 YEAR FLOOD ZONE
AS EVIDENCED ON FEMA PANEL # 47187C0165F OF WILLIAMSON COUNTY, TN, DATED 09/29/2006 AND
FEMA PANEL # 47187C0170F OF WILLIAMSON COUNTY, TN, DATED 09/29/2006.
DATE
T-SQUARE
drawn by:
AS SHOWN
scale:
04/01/26
date: NO. REVISIONS
khm
reviewer:
SrRMect
21-0831-1
sheet
THE ARBORS AT LEIPERS FORK AMENITY CENTER
6201 MAYVIEW PASS, FRANKLIN, TN
MAP 94, PARCEL 38.17
WILLIAMSON COUNTY, TENNESSEE 37064
T-SQUAREENGINEERING
OWNER OF RECORD
BABY CE CREWS JR/BABY CC TRUST
555 GREAT CIRCLE ROAD, NASHVILLE, TN 37228
TAX MAP 94, PARCEL 38.17
DEED BOOK 9543, PAGE 557
KELSEY H. MAGEE
REGISTERED ENGINEER
No. 127740
COMMERCE
STATE OF TENNESSEE
AGRIC8LT8RE
04/13/2026
1 04/13/26 REVISIONS PER STAFF COMMENTS
Sheet Schedule
C-0.0 Cover Sheet
C-1.0 Existing Conditions
C-1.1 Resource Protection Plan
C-1.2 Slope Analysis
C-2.0 Site Plan
C-5.0 Grading & Roadway Plan and Profile
AMENITY CENTER
MAYVIEW PASS
LAUREL VALLEY DR
HARGROVE RD
P:\Projects\2021\21-0831 (Hargrove Rd. - Greg Templeton)\Production\Amenity Center\21-0831 2 Amenity Site Plan.dwg, 4/20/2026 3:16:00 PM
ATTACHMENT 29-1A
LEGEND
PROPOSED LOT LINES
PROPOSED LOT NUMBER
PROPOSED BUILDING SETBACK
PROPOSED ACCESS EASEMENT
PROPOSED WATER LINE
PROPOSED WATER SERVICE
00
LEGEND
PROPOSED LOT LINES
PROPOSED LOT NUMBER
PROPOSED BUILDING SETBACK
PROPOSED ROW DEDICATION
PROPOSED WATER LINE
PROPOSED WATER SERVICE
IRON PIN FOUND
W
25-FT SETBACK
25-FT SETBACK
25-FT SETBACK
25-FT SETBACK
B
E
C
D
AF
AB
C
D
E
F
G
H
J
D
E
F
G
H
E
F
100' MBSL
100' MBSL
104' MBSL
111' MBSL
4''W
4''W
4''W
4''W
4''W
4''W
4''W
4''W
4''W
4''W
4''W
4''W
4''W
4''W
4''W
4''W
4''W
4''W
4''W
4''W
4''W
4''W
4''W
4''W
4''W
0+00
1+00
2+00
3+003+03
4''W
4''W
4''W
4''W
4''W
4''W
4''W
4''W
C29
L18
C30
C46
C47
C48
C49
C50
C51
C52 L21
C53
S58° 46' 54"W
151.01'
N61° 20' 55"E395.04'
N27° 41' 23"E162.12'
N30° 05' 35"E419.04'
L381
L382
L383
L384
L385L386
L387
L388
L389
L390 L391
L392
L393
L394
L422
25' MBSL
FRONT OF PARCEL
N16° 56' 05"E
587.19'
S39° 05' 06"E
44.08'
N61° 20' 55"E320.22'
N61° 20' 55"E141.02'
S78° 49' 23"E
321.73'
N74° 37' 59"E
162.85'
S46° 06' 52"E
235.11'
C16
L7
C17
L9
C18
L11
C19
L13
C20
C21
L35
C55
L37
C59
L57
C60
L61
C61
C62
L63
AM-HW1
AM-HW2
SITE PLAN
C-2.0
GENERAL NOTES:
1. THIS PROPERTY HAS BEEN REVIEWED FOR THE EXISTENCE
OF INTERMITTENT AND PERENNIAL STREAMS. STREAMS
THAT WOULD REQUIRE WATERWAY NATURAL AREAS AS
DESCRIBED IN SECTION 4 OF THE WILLIAMSON COUNTY
STORM WATER MANAGEMENT REGULATIONS HAVE BEEN
LOCATED AS SHOWN.
2. THIS SITE HAS BEEN REVIEWED FOR THE PRESENCE STEEP
SLOPES, HILLTOPS AND RIDGETOPS, SLIPPAGE SOILS, AND
KARST FEATURES. AREAS FALLING WITHIN THESE
CATEGORIES WILL BE ADDRESSED PER THE WILLIAMSON
COUNTY ZONING CODE.
3. THIS SITE HAS BEEN REVIEWED FOR THE PRESENCE OF
KARST FEATURES. NO KARST FEATURES WERE FOUND
4. THIS SITE HAS BEEN REVIEWED FOR THE PRESENCE OF
STEEP SLOPES.
5. WITHIN THE WATERWAY NATURAL AREA, THERE SHALL BE
NO CLEARING, GRADING, CONSTRUCTION OR DISTURBANCE
OF VEGETATION EXCEPT AS PERMITTED BY THE WILLIAMSON
COUNTY ENGINEERING DEPARTMENT.
6. ALL NATURE TRAILS WILL BE MINIMUM 15FT OFF OF THE TOP
OF STREAM BANKS. THE NATURE TRAILS WILL BE
PERMEABLE AND WILL BE FIELD LOCATED PRIOR TO
CONSTRUCTION.
7. THE SITE HAS BEEN REVIEWED FOR SPECIAL FLOOD HAZARD
AREAS AND WETLAND AREAS, NONE FOUND ON SITE.
8. THE AMENITY CENTER IS LOCATED INTERNAL TO THE
SUBDIVISION IN OPEN SPACE-102 AS RECORDED IN BOOK
P86, PAGE 132 OF THE ARBORS AT LEIPERS FORK
SUBDIVISION, PHASE 1.
APPLICANT
T-SQUARE ENGINEERING
111 SE PARKWAY CT
FRANKLIN, TN 37064
615.678.8212
FLOOD NOTE
NO PORTION OF THIS PROPERTY IS LOCATED IN AN AREA DESIGNATED AS A 100 YEAR FLOOD ZONE
AS EVIDENCED ON FEMA PANEL # 47187C0165F OF WILLIAMSON COUNTY, TN, DATED 09/29/2006 AND
FEMA PANEL # 47187C0170F OF WILLIAMSON COUNTY, TN, DATED 09/29/2006.
DATE
T-SQUARE
drawn by:
AS SHOWN
scale:
04/01/26
date: NO. REVISIONS
khm
reviewer:
SrRMect
21-0831-1
sheet
THE ARBORS AT LEIPERS FORK AMENITY CENTER
6201 MAYVIEW PASS, FRANKLIN, TN
MAP 94, PARCEL 38.17
WILLIAMSON COUNTY, TENNESSEE 37064
T-SQUAREENGINEERING
OWNER OF RECORD
BABY CE CREWS JR/BABY CC TRUST
555 GREAT CIRCLE ROAD, NASHVILLE, TN 37228
TAX MAP 94, PARCEL 38.17
DEED BOOK 9543, PAGE 557
KELSEY H. MAGEE
REGISTERED ENGINEER
No. 127740
COMMERCE
STATE OF TENNESSEE
AGRIC8LT8RE
04/13/2026
1 04/13/26 REVISIONS PER STAFF COMMENTS
T.C.A.0400-45-09-.17
GEOTHERMAL WELL CONSTRUCTION STANDARDS FOR
CLOSED LOOP GEOTHERMAL BOREHOLES
SOURCE OF STRUCTURE MINIMUM DISTANCE
SEWER LINES 10 FEET
SEPTIC TANKS 25 FEET
SPRINGS 100 FEET
SEPTIC DRAIN FIELDS 25 FEET
WATER WELLS 100 FEET
HOUSE TO SEPTIC TO TANK CONNECTION 10 FEET
HOUSE TO SEWER CONNECTION 10 FEET
25' DRAINAGE
EASEMENT (TYP.)
MAYVIEW PASS (PVT)
( IN FEET )
GRAPHIC SCALE
0 50 10050 25
SCALE: 1" = 50'
LAUREL VALLEY DR (PVT)
CAROTENE COURT (PVT)
60' WNA BUFFER
60' WNA BUFFER
FORMAL LAWN
TRAIL
PLAYGROUND
SPORT COURT
PAVILION
PAVILION WITH FIREPLACE
RETAINING WALL -
DESIGNED BY OTHERS
RETAINING WALL -
DESIGNED BY OTHERS
STAIRS, TYP. -
6" RISER, 18" TREAD
6'
5'
5'
4'
4'
5'
5'
8'
8'
8'
14'
R5'
R5'R5'
R5'R5'
5'
11'
5'
5'
18'
9'
9'
15'
15'22'
22'15'R5'
R5'
5'
5'
19'
TRAIL
SITE DATA
MAP 94, PARCEL 38.17 EXISTING PROPOSED
TOTAL PROPERTY ACREAGE 51.41 51.41
ZONING RD-5 RD-5
USE OPEN
SPACE
OPEN
SPACE
MAXIMUM GROSS FLOOR AREA 1,225 SF
MAXIMUM BUILDING HEIGHT
25.7'
MINIMUM BUILDING HEIGHT
FRONT SETBACK 100'
SIDE SETBACK 25'
REAR SETBACK 50'
AUTOMOBILE PARKING SPACES 0 13
ADA PARKING SPACES 0 1 TOT, 1 VAN
PARKING CALCULATIONS:
1. RESIDENTIAL OPEN SPACE
1.1. REQUIRED: 26 LOTS *(1.0 SPACE PER 2
HOMES) = 13 SPACES
1.2. PROVIDED: 13 SPACES
NOTES:
1. ARBORS AT LEIPERS FORK IS A PRIVATE,
GATED SUBDIVISION WITH PRIVATE ROADS.
2. NO WASTEWATER AREAS ARE PROPOSED.
3. AMENITY CENTER IS FOR PRIVATE USE
WITHIN THE SUBDIVISION ONLY.
4. TOPOGRAPHIC INFORMATION PROVIDED BY
T-SQUARE SURVEYING, DATED 2/24/2026.
RESOURCE PROTECTION NOTE:
THIS SITE HAS BEEN REVIEWED FOR THE PRESENCE OF STEEP SLOPES, HILLTOPS AND
RIDGETOPS, SLIPPAGE SOILS, SPECIAL FLOOD HAZARDS, HISTORICAL AND CULTURAL
RESOURCES, AND KARST FEATURES. AREAS FALLING WITHIN THESE CATEGORIES, IF ANY,
HAVE BEEN NOTED ON THE RESOURCE PROTECTION PLAN. THERE HAVE BEEN NO KARST
FEATURES FOUND ON THIS PROPERTY. THERE ARE NO SLIPPAGE SOILS INDICATED BY THE
APPROVED SOIL MAP OR WC WEB SOIL SURVEY. THERE ARE NO HISTORICAL OR CULTURAL
RESOURCES KNOWN IN THESE LOTS. THERE IS NO HILLTOP/RIDGETOP ON THIS PROPERTY,
AS DETERMINED BY WC PLANNING DIRECTOR MICHAEL MATTESON.
THERE ARE STEEP SLOPES ON THE PROPERTY. VERY STEEP SLOPES (25% OR GREATER)
OF 5000 SF OR LARGER HAVE BEEN REMOVED FROM BUILDABLE AREAS. BUILDABLE AREAS
WITH MODERATELY STEEP SLOPES (15% - 25%) ARE LOCATED WITHIN THE PROPOSED
LIMITS OF DISTURBANCE. AN ENGINEERED SITE PLAN HAS BEEN PROVIDED WITHIN THE
CONSTRUCTION DOCUMENTS FOR THIS DEVELOPMENT.
HYDROLOGIC DETERMINATION REPORTS WERE COMPLETED BY BDY ENVIRONMENTAL ON
APRIL 15, 2022 AND MAY 19, 2022. 103 WATERWAYS AND CONVEYANCES WERE IDENTIFIED
ON THE PARENT PARCEL. THE LIMITS OF DISTURBANCE DOES NOT ENCROACH ON
WATERWAY NATURAL AREA BUFFERS. DRAINAGE AREAS GREATER THAN 5 ACRES HAVE
BEEN DELINEATED WITH A 25-FT DRAINAGE EASEMENT. THERE ARE NO WETLANDS
INDICATED ON THE REPORT.
THIS PROPERTY IS 100% (51.41 AC) COVERED IN EXISTING TREE CANOPY. PER REGULATION,
48% (24.68 AC) MUST BE PRESERVED IN THIS PHASE. 92.8% (50.51 AC) OF THE EXISTING TREE
CANOPY IS PROPOSED AS BEING PRESERVED. TOTAL TREE CANOPY DISTURBED BY
DEVELOPMENT IS 7.2% (0.9 AC).
103' TO R.O.W.
236' TO R.O.W.
144' TO R.O.W.
P:\Projects\2021\21-0831 (Hargrove Rd. - Greg Templeton)\Production\Amenity Center\21-0831 2 Amenity Site Plan.dwg, 4/20/2026 3:16:32 PM
ATTACHMENT 29-1B
ATTACHMENT 29-2
Item 30—Page 1 of 1
Reviewer: LS
Date: 5/14/2026
ITEM 30
PRELIMINARY PLAT REVIEW FOR DODD FAMILY REVOCABLE LIVING TRUST
SUBDIVISION, CONTAINING 1 LOT ON 32.12 ACRES LOCATED OFF
TALIAFERRO ROAD IN THE 5TH VOTING DISTRICT (1-2026-305).
Area 32.12 acres
Zoning Rural Development-5 (RD-5)
Lots 1
Water Nolensville/College Grove Utility District
Sewer Individual On-Site Septic Systems
Development Option Large Lot Easement
Chapter 1101 Status Rural
Map and Parcel 140---01414
File Number (1-2026-305)
At this time, the applicant is requesting deferral to the June 2026 Planning Commission
Meeting in order to allow the applicant more time to address Staff comments. Staff
concurs with this request.
Item 31—Page 1 of 2
Reviewer: LS
Date: 5/14/2026
ITEM 31
PRELIMINARY PLAT REVIEW FOR HALEY VALLEY LARGE LOT EASEMENT
SUBDIVISION, CONTAINING 5 LOTS ON 25.12 ACRES LOCATED OFF
MURFREESBORO ROAD IN THE 5TH VOTING DISTRICT (1-2026-307).
Attachment 31-1 Preliminary Plat
31-2 Aerial Photograph
Area 25.12 acres
Zoning Rural Development-5 (RD-5)
Lots 5
Water Nolensville/College Grove Utility District
Sewer Triune Sewer Facility
Development Options Large Lot Easement
Chapter 1101 Status Rural
Map and Parcels 113---05502 and 05403
File Number (1-2026-307)
The subject parcel is 2 5.12 acres in size and is located off Murfreesboro Road. The
applicant is requesting approval of a Large Lot Easement Subdivision in order to create
five (5) lots off a new fifty-foot (50’) ingress/egress/utilities easement. The easement has
TDOT-approved connection to Murfreesboro Road.
The site contains natural resources requiring protection, including steep slopes, wetlands,
Waterway Natural Areas (WNAs), and tree canopy. All Zoning Ordinance requirements,
including those regarding the protection of natural resources, have been met.
The applicant is proposing to connect the lots to Triune Sewer Facility, and Williamson
County’s wastewater consultant has confirmed sewer capacity and has recommended
approval from a wastewater standpoint . Water will be provided by Nolensville/College
Grove Utility District. Proposed fire hydrants meet the minimum flow rate of 500 gpm
and are located no further than 500 feet from all parts of all building envelopes.
The Preliminary Plat is in order, and Staff recommends approval, subject to the following
conditions, which must be addressed in conjunction with Final Plat submittal:
1. A Notice of Coverage issued by TDEC will be required prior to the issuance of a
Land Disturbance Permit;
2. Fire hydrants shall be installed and functioning and flow reports submitted proving
they meet the 500 gpm standard, prior to Final Plat approval;
Item 31—Page 2 of 2
Reviewer: LS
Date: 5/14/2026
3. Establishment of a Performance Bond for water improvements in favor of
Nolensville/College Grove Utility District;
4. Establishment of a performance bond for the wastewater collection system;
5. Submission of road names for review and approval by the Williamson County
Emergency Management Agency (EMA);
6. A Land Disturbance Permit must be obtained for the overall development; and
7. Prior to submittal of the Final Plat, driveway and drainage infrastructure must be
complete, consistent with Zoning Ordinance requirements. The applicant shall
notify Staff in order to conduct the required inspection.
154.68'
N77° 01' 11"E
154.68'
S12° 46' 37"E
525.96'
SCALE: 1"=100'
ARTICLE 13 RESOURCE PROTECTION NOTE:
SEWER SYSTEM EASEMENT NOTE:
Contact
Natalia Powell
Triune Development, LLC
P.O. Box 190 Arrington, TN 37014
(615) 395-0047
Developer:
1301 ASHBY VALLEY LANE
TRIUNE DEVELOPMENT, LLC
ARRINGTON, TN 37014
MAP 113- PARCELS 55.02 ,PART OF 54.02, 54.03 MAP 113-PARCEL 55.02 Book 9522, pg. 131
ZONED RD-5 ZONED RD-5
Owner:
1301 ASHBY VALLEY LANE
TRIUNE DEVELOPMENT, LLC (Jay Russ)
ARRINGTON, TN 37014
M
M
M
M
M
PO Box 1012
Smyrna, TN 37167-1012
(615) 347-5918
pjernigan@hfrsurvey.com
(615) 519-3935
dreagan@hfrsurvey.com
MAP 113- PARCEL54.03 MAP 113-PARCEL 54.03 BOOK 9956-PG 571
MAP 113- PARCEL PART OF 54.02 MAP 113-PARCEL PART OF 54.02 BOOK 9956-PG 575
10001
866.558
FN1 WOVEN WIRE/FENCE POST
10003
868.566
FN1
10006
871.254
FN1
10008
874.836
FN1
EXISTING
FARM
POND
EXISTING WETLAND BUFFER AREA (WTL-2)
EXISTING WETLAND BUFFER AREA
(WTL-2)
EXISTING WETLAND BUFFER
AREA (WTL-2)
EXISTING WETLAND
BUFFER AREA (WTL-2)
EXISTING
WETLAND
BUFFER AREA
(WTL-2)
EXISTING
WETLAND
BUFFER
AREA
(WTL-2)
EXISTING
WETLAND
BUFFER
AREA
(WTL-2)
EXISTING WETLAND
BUFFER AREA
(WTL-2)
EXISTING WETLAND BUFFER AREA (WTL-2)
EXISTING WETLAND BUFFER AREA (WTL-2)EXISTING WETLAND BUFFER AREA (WTL-2)EXISTING WETLAND BUFFER AREA (WTL-2)EXISTING
WETLAND
BUFFER AREA
(WTL-2)
EXISTING
WETLAND AREA
(WT-1)
EXISTING
WETLAND AREA
(WT-1)
EXISTING WETLAND AREA (WT-1)
EXISTING
WETLAND AREA
(WT-1)
EXISTING
WETLAND AREA
(WT-1)
EXISTING
WETLAND AREA
(WT-1)
EXISTING
WETLAND AREA
(WT-1)
EXISTING
WETLAND AREA
(WT-1)
EXISTING
WETLAND AREA
(WT-1)
EXISTING
WETLAND AREA
(WT-1)
EXISTING
WETLAND AREA
(WT-1)
EXISTING
WETLAND AREA
(WT-1)
EXISTING
WETLAND AREA
(WT-1)
EXISTING
WETLAND AREA
(WTL-2)
EXISTING
WETLAND AREA
(WTL-2)
EXISTING
WETLAND AREA
(WTL-2)
EXISTING
WETLAND AREA
(WTL-2)
EXISTING
WETLAND AREA
(WTL-2)
EXISTING
WETLAND AREA
(WTL-2) EXISTING
WETLAND AREA
(WTL-2)
EXISTING
WETLAND AREA
(WTL-2)
EXISTING
WETLAND AREA
(WTL-2)
EXISTING
WETLAND AREA
(WTL-2)
EXISTING
WETLAND AREA
(WTL-2)
EXISTING
WETLAND AREA
(WTL-2)
EXISTING
WETLAND AREA
(WTL-2)
EXISTING
WETLAND AREA
(WT-1)
EXISTING
WETLAND AREA
(WT-1)
EXISTING
WETLAND AREA
(WT-1)
EXISTING
WETLAND AREA
(WT-1)
EXISTING
WETLAND AREA
(WT-1)
EXISTING
WETLAND AREA
(WT-1)
EXISTING
WETLAND AREA
(WT-1)
EXISTING
WETLAND AREA
(WT-1)
EXISTING
WETLAND AREA
(WT-1)
EXISTING WETLAND AREA (WT-1)
EXISTING
WETLAND AREA
(WT-1)
EXISTING
WETLAND AREA
(WT-1)
EXISTING
WETLAND AREA
(WT-1)
EXISTING WETLAND BUFFER AREA (WTL-1)
EXISTING WETLAND BUFFER AREA
(WTL-1)
EXISTING WETLAND BUFFER
AREA (WTL-1)
EXISTING WETLAND
BUFFER AREA (WTL-1)
EXISTING
WETLAND
BUFFER AREA
(WTL-1)
EXISTING
WETLAND
BUFFER
AREA
(WTL-1)
EXISTING
WETLAND
BUFFER
AREA
(WTL-1)
EXISTING WETLAND
BUFFER AREA
(WTL-1)
EXISTING WETLAND BUFFER AREA (WTL-1)
EXISTING WETLAND BUFFER AREA (WTL-1)EXISTING WETLAND BUFFER AREA (WTL-1)EXISTING WETLAND BUFFER AREA (WTL-1)EXISTING
WETLAND
BUFFER AREA
(WTL-1)
06
E
AGRICULTURE
91
.
R YO
C
O
SSE
REG
ET
NN
CRM EM
NEE
E
O
RV
UER
TE
IS
NDLAD
IXV S
ATTACHMENT 31-1
Item 32—Page 1 of 1
Reviewer: LS
Date: 5/14/2026
ITEM 32
FINAL PLAT REVIEW FOR FOSTER SUBDIVISION FAMILY SUBDIVISION,
CONTAINING 1 LOT ON 1.40 ACRES LOCATED OFF TALIAFERRO ROAD IN THE
5TH VOTING DISTRICT (1-2026-409).
Area 1.40 acres
Zoning Rural Development-5 (RD-5)
Lots 1
Water Nolensville/College Grove Utility District
Sewer Individual On-Site Septic System
Development Option Family Subdivision
Chapter 1101 Status Rural
Map and Parcel 140---01413
File Number (1-2026-409)
At this time, the applicant is requesting deferral to the June 2026 Planning Commission
Meeting in order to allow the applicant more time to address Staff comments. Staff
concurs with this request.
Item 33—Page 1 of 1
Reviewer: JYJ
Date: 5/14/2026
ITEM 33
FINAL PLAT REVIEW FOR LOT 201 OF ARTESIAN ACRES SUBDIVISION,
CONTAINING 1 LOT ON 5 ACRES LOCATED OFF ARTESIAN DRIVE IN THE 5TH
VOTING DISTRICT (1-2026-405).
Attachment 33-1 Final Plat
33-2 Aerial Photograph
Area 5 acres
Zoning Municipal Growth Area–1 (MGA-1)
Lots 1
Water Nolensville College Grove Utility District
Sewer Individual On-site Septic System
Development Options Rural
Map and Parcel 59—091.10
File Number (1-2026-405)
A Preliminary Plat for this lot was approved at the March 2026 meeting. The applicant is
now requesting Final Plat approval of Section 2, which contains one (1) lot. Sewer service
will be provided by an on-site septic system. All required infrastructure has been installed,
and therefore no performance bonds are required.
The plat is consistent in l ayout with that depicted on the Preliminary Plat, and therefore
Staff recommends approval of the Final Plat with the condition the applicant provide two
(2) copies of the approved Final Plat in .dwg format on recordable media based on the
Tennessee State Plane Coordinate System prior to signature and recording of the Final
Plat.
MB
14" CULVERT
KENNETH E. MOORE
MARY BETH MOORE
2013 ARTESIAN DR.
DEED BOOK 694, PAGE 688 R.O.W.C.
PLAT BOOK 10, PAGE 165 R.O.W.C.
MAP 59 PARCEL 91.09
S78° 20' 52"W
919.79'
N77° 15' 43"E
1001.39'
C1
JUDY HILL
DANNIE HILL
2019 ARTESIAN DR.
DEED BOOK 5487, PAGE 323 R.O.W.C.
PLAT BOOK 12, PAGE 9 R.O.W.C.
MAP 59 PARCEL 91.11
CONCRETE DRIVE
1/2" IP SET
SSDS AREA (A)
5,014 SQ FT
60MPI MLPP
5-15%
SSDS AREA (B)
5,064 SQ FT
60MPI MLPP
5-15%
INTERCEPTOR DRAIN
SSDS SETBACK
A
C
D
(E2)
(E3)
(D3)
DIRT ROAD
DIRT ROAD
LOT 201
5.00 ± ACRES
(217, 666 ± SQ FT)
ARTESIAN DRIVE (PRIVATE 50' WIDTH)
S22° 00' 05"W
232.64'
MAILBOX
N07° 58' 16"E
231.90'
100 FT M.B.S.L.
20 FT M.B.S.L.
20 FT M.B.S.L.
FOUND 1/2" IP
FOUND 1/2" IP
FOUND 1/2" IP
FOUND 1/2" IP
(D4)
(F2)B
DRAINAGEEASEMENT
v
vvv
v
1
15'
25'
20'
(C3)
(B3)
15'
20'
DRAINAGEEASEMENT
DRAINAGEEASEMENT
25.00'
25.00'
25.00'
E
F
G
20.9'
LOT D
707.0' 705.1'
704.5' 707.1'
CURTAIN DRAIN ELEVATION TABLE
OUTLET 704.1'
MIN. DEPTH
1 36"
GND. ELV.
INV. ELV.
A B C
710.0' 708.1'
E
705.5'
702.5'
F
701.4'
OUTLET
G
706.3'
703.3'
KEYNOTES:
1
ISOLATED ROCK (5' SETBACK REQUIRED)
OLD FENCE ROW/TERRACE MAY BE DISKED, SMOOTHED, AND
INSTALLED THROUGH UNDER W.C.D.S.D.M. SUPERVISION.
v
SITE
EXISTING WATER MAIN
EXISTING OVERHEAD ELECTRICAL
EXISTING MAILBOXMB
IRON PIPE / PIN FOUND
RIGHT-OF-WAY
25' DRAINAGE EASEMENT
DIRT ROAD
ASPHALT PAVEMENT
CAPPED REBAR SET
RIGHT-OF-WAYR.O.W.
MINIMUM BUILDING SETBACK LINEM.B.S.L.
PLAT BOOKPB.
DEED BOOKDB.
PAGEPG.
RECORD DIMENSION( )
LEGEND
BOUNDARY LINE
CONCRETE PAVEMENT
EXISTING CULVERT
M.B.S.L.
OLD FENCE ROW
SECTION 2 FINAL PLAT
E
ROYEVRUSDNALDERETSI
GER
RELHAHPESOJ
TENNESSEE NO. 143
.
4
DEPARTMENT OF SEWAGE DISPOSAL MANAGEMENT NOTES
THE AREA FOR SUBSURFACE SEWAGE DISPOSAL SYSTEM IS SHOWN THUS:
1. LOT 201 IS RESTRICTED TO ONE, (4) BEDROOM, SINGLE FAMILY DWELLING.
2. DESIGNATED SEWAGE DISPOSAL AREAS SHOWN ON THIS PLAT PLOTTED IN ACCORDANCE WITH ACCEPTABLE SOIL AREAS FIELD MAPPED BY J. MICHAEL
HAARBAUER, PRIVATE CONSULTING SOIL CONSULTANT, ON 6/18/24 AND REVISED 07/12/2024.
3. ANY CUTTING, FILLING, COMPACTION OF THE SOILS FROM THEIR NATURAL STATE, OF THE SOIL AREAS RESERVED FOR SEWAGE DISPOSAL, SHALL RESULT IN
REVOCATION OF THE LOT APPROVAL. ADDITIONALLY, THE DEPARTMENT SHALL HAVE AUTHORITY TO REFUSE TO GRANT A CONSTRUCTION PERMIT OR MAY REVOKE A
CONSTRUCTION PERMIT WHERE THE INTEGRITY OF THE PROPOSED SUBSURFACE SEWAGE DISPOSAL SYSTEM AREAS HAVE BEEN COMPROMISED.
4. ALL SEPTIC SYSTEMS MUST BE INSTALLED BY AN INSTALLER LICENSED BY WILLIAMSON COUNTY TO CONSTRUCT ALTERNATIVE OR CONVENTIONAL SEPTIC SYSTEMS.
5. NO UTILITIES (I.E. GAS, WATER, OR ELECTRIC) OR THEIR EASEMENTS, ABOVE OR BELOW GROUND, SHALL BE ALLOWED TO ENCROACH WITHIN 10 FEET OF THE
BOUNDARIES OF THE SOIL AREAS RESERVED FOR SEWAGE DISPOSAL.
6. CURTAIN/INTERCEPTOR/DRAWDOWN DRAINS MAY BE REQUIRED ON ANY OR ALL LOTS. AS SUCH, THEY SHALL ADHERE TO THE DESIGN, LOCATION AND ROUTING
DEPICTED ON THIS PLAT. HOWEVER, THE DRAINS AS SHOWN MAY BE SUBJECT TO CHANGE AT THE SOLE DISCRETION OF THE WILLIAMSON COUNTY DEPARTMENT OF
SEWAGE DISPOSAL MANAGEMENT AS DEEMED NECESSARY BY THEIR FIELD INVESTIGATION AT THE TIME OF SUBMITTAL OF EACH INDIVIDUAL LOTS ALTERNATIVE
SYSTEM SITE AND DESIGN PLANS. THE WILLIAMSON COUNTY DEPARTMENT OF SEWAGE DISPOSAL MANAGEMENT'S EVALUATION WILL BE CONDUCTED ON A
SITE-SPECIFIC, LOT BY LOT BASIS.
7. NO IRRIGATION SYSTEMS, OR THEIR COMPONENTS THEREOF, SHALL ENCROACH ON, IN OR WITHIN 10 FEET OF THE BOUNDARIES OF THE DESIGNATED OR PLATTED
SSDS AREAS. IT SHALL ALSO BE LOCATED A MINIMUM OF 5 FEET AWAY FROM ANY DRAINAGE IMPROVEMENT PRACTICE ASSOCIATED WITH THE SSDS AREA.
8. NO CUTTING, FILLING, OR COMPACTION OR ANY OTHER DISTURBANCE OF THE AREAS RESERVED FOR SEWAGE DISPOSAL SHALL BE PERMITTED.
9. THE LIMITS OF ALL EXCAVATIONS GREATER THAN 18 INCHES IN DEPTH, MADE FOR THE PURPOSE OF HOUSE CONSTRUCTION (OR ANY OTHER TYPE OF BUILDING
CONSTRUCTION), SHALL BE KEPT 25 FEET OR MORE AWAY FROM THE PLATTED OR DESIGNATED SEWAGE DISPOSAL AREAS.
10. THE LIMITS OF ALL EXCAVATIONS, MADE FOR THE PURPOSE OF HOUSE CONSTRUCTION (OR ANY OTHER TYPE OF BUILDING CONSTRUCTION), SHALL BE KEPT WITHIN
THE CONFINES OF THE PLATTED BUILDING ENVELOPE.
11. NO CONSTRUCTION OF PATIOS, SWIMMING POOLS, ACCESSORY BUILDINGS, ETC. SHALL BE ALLOWED ON ANY LOT SERVED BY A SUBSURFACE SEWAGE DISPOSAL
SYSTEM, UNLESS APPROVED BY THE DEPARTMENT OF SEWAGE DISPOSAL MANAGEMENT.
12. WATER SERVICE LINES MUST BE SEPARATED FROM SEWAGE DISPOSAL AREAS OR PLATTED DISPOSAL FIELD AREAS BY A MINIMUM OF 10 FEET.
13. NO WATER SOURCE, WELLS OR SPRINGS ARE TO BE DRILLED OR CONSTRUCTED OR WITHIN 50 FEET OF ANY PORTION OR COMPONENT OF THE SEPTIC SYSTEM OR
THE DESIGNATED OR PLATTED SEWAGE DISPOSAL FIELD AREAS. THIS INCLUDES THE SEPTIC TANK, TIGHTLINES, ALTERNATING VALVES, OR THE DESIGNATED OR
PLATTED SEWAGE DISPOSAL FIELD AREAS.
14. ALL PLATTED SEWAGE DISPOSAL AREAS SHALL BE FIELD STAKED BY A LICENSED SURVEYOR AND FENCED OFF, TO PROTECT THE AREAS FROM ALL CONSTRUCTION
TRAFFIC, BY THE PROPERTY OWNER OR BUILDING CONTRACTOR. THE AREAS THEN SHALL BE FIELD CHECKED AND VERIFIED BY THE DEPARTMENT OF SEWAGE
DISPOSAL MANAGEMENT PRIOR TO THE ISSUANCE OF THE SEPTIC PERMIT.
15. THE EXACT LOCATION OF THE WATER SOURCE (I.E. WELL, CISTERN, SPRING OR PRIVATE WATER SOURCE) MUST BE FIELD LOCATED BY A SURVEYOR OR ENGINEER ON
A COPY OF THIS PLAT AND SUBMITTED TO THE DEPARTMENT OF WILLIAMSON COUNTY DISPOSAL MANAGEMENT FOR REVIEW AND RECORD KEEPING PURPOSES.
16. PRIOR TO INSTALLATION, THE LOCATION OF THE WELL, SPRING, CISTERN OR PRIVATE WATER SOURCE MUST BE APPROVED BY THE WILLIAMSON COUNTY
DEPARTMENT OF SEWAGE DISPOSAL MANAGEMENT.
17. LOCATION OF WELL, SPRING, CISTERN OR PRIVATE WATER SOURCE MUST BE A MINIMUM OF 50 FEET AWAY FROM ANY SEWAGE DISPOSAL AREA, INCLUDING THOSE
LOCATED UPON ADJACENT LOTS.
18. THERE SHALL BE NO SEWAGE CONVEYANCES (PIPES, SUPPLY LINES, MANIFOLDS, SEPTIC OR PUMP TANKS, ETC.) LOCATED WITHIN 50 FEET OF ALL WELL(S) ON THIS
PROPERTY.
19. SSDS COMPONENTS CROSSING UTILITIES AND THEIR RELATED EASEMENTS, IN ADDITION TO DRIVEWAYS, ACCESS EASEMENTS. ETC: ANY AND ALL SSDS
COMPONENTS (INCLUDING BUT NOT LIMITED TO: CURTAIN DRAINS, SEWAGE SUPPLY LINES, MANIFOLDS, ETC.) SHALL BE SHEATHED AND BEDDED (AS PER
SPECIFICATIONS FROM WCDSM) WHERE THEY CROSS ANY DRIVEWAY, ACCESS EASEMENT, UTILITY LINES (AND THEIR RELATED EASEMENTS). THE SHEATHING SHALL
EXTEND FROM A POINT 10 FEET PRIOR TO ENTERING ANY EASEMENT AND SHALL EXTEND THROUGHOUT THE ENTIRE WIDTH OF THE EASEMENT AND SHALL END AT A
POINT 10 FEET PAST THE LIMITS OF ANY EASEMENT. ALL CROSSINGS MUST BE IN ACCORDANCE WITH THE REQUIREMENTS OF THE WILLIAMSON COUNTY
DEPARTMENT OF SEWAGE DISPOSAL MANAGEMENT. ALL SHEATHING MUST BE SCHEDULE 80 PVC OR DUCTILE IRON AND BE BEDDED IN 12" OF GRAVEL.
20. CS DENOTES THAT THIS LOT IS SERVED BY A CONVENTIONAL MEANS OF SUBSURFACE SEWAGE DISPOSAL SYSTEM; LPP DENOTES THAT THIS LOT IS SERVED BY A
LOW PRESSURE PIPE SYSTEM, WHICH IS AN ALTERNATIVE MEANS OF SEWAGE DISPOSAL; MLPP DENOTES THAT THIS LOT IS SERVED BY A MODIFIED LOW PRESSURE
PIPE SYSTEM, WHICH REQUIRES 6 TO 10 INCHES OF COMPATIBLE SOIL FILL MATERIAL TO BE INCORPORATED ONTO THE DESIGNATED OR PLATTED SEWAGE
DISPOSAL AREA UNDER DEPARTMENT OF SEWAGE DISPOSAL MANAGEMENT SUPERVISION.
21. BEFORE A PERMIT TO CONSTRUCT A CONVENTIONAL SYSTEM SERVING SINGLE SOURCE WITH A PROJECTED WASTEWATER FLOW RATE EXCEEDING 750 GALLONS
PER DAY (gpd), DETAILED SITE AND DESIGN PLANS FOR SAID SYSTEM SHALL BE SUBMITTED TO THE DEPARTMENT OF SEWAGE DISPOSAL MANAGEMENT FOR REVIEW
AND APPROVAL. THESE PLANS SHALL BE PREPARED BY AN ENGINEER LICENSED IN THE STATE OF TENNESSEE.
22. BEFORE A PERMIT TO CONSTRUCT A LPP OR MLPP SEPTIC SYSTEM CAN BE ISSUED, DETAILED SITE AND DESIGN PLANS FOR THE LPP OR MLPP SYSTEM SHALL BE
SUBMITTED TO THE DEPARTMENT OF SEWAGE DISPOSAL MANAGEMENT FOR REVIEW AND APPROVAL. THESE PLANS SHALL BE PREPARED BY AN ENGINEER
LICENSED IN THE STATE OF TENNESSEE.
23. AN ARAP PERMIT MUST BE OBTAINED FROM THE STATE OF TENNESSEE AT THE DEPARTMENT OF ENVIRONMENT AND CONSERVATION BEFORE ANY CONSTRUCTION,
EXCAVATION, CLEARING OR GRADING ACTIVITIES CAN OCCUR WITHIN THE CREEK OR WATERWAY NATURAL AREA.
24. (T.C.A. 0400-45-09-.17) GEOTHERMAL WELL CONSTRUCTION STANDARDS FOR CLOSED LOOP GEOTHERMAL BOREHOLES;
SOURCE OF STRUCTURE MINIMUM DISTANCES
SEWER LINE 10'
SEPTIC TANK 25'
SPRINGS 100'
SEPTIC DRAIN FIELDS 25'
WATER WELLS 100'
HOUSE TO SEPTIC TANK CONNECTION 10'
HOUSE TO SEWER CONNECTION 10'
25. ALL PLUMBING FIXTURES TO BE OF THE WATER CONSERVATIVE TYPE, INCLUDING LOW VOLUME FLUSH TOILETS (1.6 GALLONS OR LESS), 1.5 T0 2.0 GALLONS PER
MINUTE SHOWER HEADS, AND FAUCET AERATORS.
26. THE LIMITS OF ALL EXCAVATIONS GREATER THAN 18 INCHES IN DEPTH, MADE FOR THE PURPOSE OF HOUSE CONSTRUCTION (OR ANY OTHER TYPE OF BUILDING
CONSTRUCTION), SHALL BE KEPT 25 FEET OR MORE AWAY FROM THE PLATTED OR DESIGNATED SEWAGE DISPOSAL AREAS.
27. ALL PARTS OF THE HOUSE AND ANY OF ITS RELATED APPENDAGES (INCLUDING, BUT NOT LIMITED TO DETACHED GARAGES, PORCHES, DECKS, SIDEWALKS,
DRIVEWAYS, PARKING AREAS, UTILITIES, ETC.) SHALL STRICTLY ADHERE TO THE MINIMUM SETBACK REQUIREMENTS FROM THE SUBSURFACE SEWAGE DISPOSAL
SYSTEM AREAS AS OUTLINED IN SECTION 13 OF THE REGULATIONS GOVERNING ON-SITE SEWAGE DISPOSAL MANAGEMENT, ADOPTED MAY 16, 2000, AND EFFECTIVE
OCTOBER 1, 2000.
28. THIS SITE MAY MANDATE THE USE OF A SEWAGE/EFFLUENT PUMP AND APPROPRIATELY SIZED PUMP TANK IN ORDER TO PROVIDE SEWER SERVICES FROM THE
HOUSE TO THE SSDS AREAS. THIS SHALL E SPECIFIED BY THE WILLIAMSON COUNTY DEPARTMENT OF SEWAGE DISPOSAL MANAGEMENT BASED UPON THE FINISHED
ELEVATION OF THE HOUSE PLUMBING STUB-OUT AND THE SSDS AREA.
V1.0
CERTIFICATE OF OWNERSHIP AND DEDICATION
I (WE) HEREBY CERTIFY THAT I AM (WE ARE) THE OWNER(S) OF THE
PROPERTY SHOWN AND DESCRIBED HEREON. AS EVIDENCED IN BOOK
NUMBER 9522, PAGE 680, R.O.W.C., AND THAT I (WE) HEREBY ADOPT
THIS PLAN OF SUBDIVISION WITH MY (OUR) FREE CONSENT, ESTABLISH
THE MINIMUM BUILDING RESTRICTION LINE, AND THAT OFFERS OF
IRREVOCABLE DEDICATION FOR ALL PUBLIC STREETS, UTILITIES AND
OTHER FACILITIES HAVE BEEN FILED AS REQUIRED BY THESE
REGULATIONS.
OWNER #1 SIGNATURE DATE
CERTIFICATE OF ACCURACY
I HEREBY CERTIFY THAT THE PLAN SHOWN AND DESCRIBED HERON IS
TRUE AND CORRECT SURVEY TO THE ACCURACY REQUIRED BY THE
WILLIAMSON COUNTY, TENNESSEE REGIONAL PLANNING COMMISSION
AND THAT THE MONUMENTS HAVE BEEN OR WILL BE PLACED AS
SHOWN HERON, TO THE SPECIFICATIONS OF THE SUBDIVISION
REGULATIONS, AS APPROVED BY THE COUNTY ENGINEER.
DATE REGISTERED LAND SURVEYOR
CERTIFICATION OF GENERAL APPROVAL FOR INSTALLATION OF
SUBSURFACE SEWAGE DISPOSAL SYSTEMS WITH RESTRICTIONS
GENERAL APPROVAL IS HEREBY GRANTED FOR LOTS PROPOSED HERON
AS BEING SUITABLE FOR SUBSURFACE SEWAGE DISPOSAL WITH THE
LISTED AND OR ATTACHED RESTRICTIONS.
BEFORE INITIATION OF CONSTRUCTION, THE LOCATION OF THE HOUSE
OR OTHER STRUCTURE AND PLANS FOR THE SUBSURFACE SEWAGE
DISPOSAL SYSTEM SHALL BE APPROVED BY THE LOCAL HEALTH
AUTHORITY.
DATE DEPT. OF SEWAGE DISPOSAL MANAGEMENT
CERTIFICATE OF APPROVAL FOR RECORDING
I HEREBY CERTIFY THAT THE SUBDIVISION PLAT SHOWN HERON HAS
BEEN FOUND TO COMPLY WITH THE SUBDIVISION REGULATIONS FOR
WILLIAMSON COUNTY, TENNESSEE, WITH THE EXCEPTION OF SUCH
VARIANCES, IF ANY, AS ARE NOTED IN THE MINUTES OF THE PLANNING
COMMISSION AND THAT IT HAS BEEN APPROVED FOR RECORDING IN
THE OFFICE OF THE COUNTY REGISTER
THIS APPROVAL SHALL BE
INVALID IF NOT RECORDED BY:
DATE
DATE SECRETARY, PLANNING COMMISSION
NOTES:
OWNER: HUMMING BIRD INV. LP.
ADDRESS: 2015 ARTESIAN DR.
NOLENSVILLE, TN 37135
WILLIAMSON COUNTY, TENNESSEE
17TH CIVIL DISTRICT
DEED: DEED BOOK 9522, PAGE 680, R.O.W.C.
TAX MAP 059, PARCEL 091.10
TOTAL ACREAGE: 5.00 ± ACRES (217,666 ± SQ FT)
SURVEY DATED: 04-22-2024
BASIS OF BEARING: FOR BOUNDARY AND TOPOGRAPHIC ASPECTS OF THIS SURVEY, RTK GPS POSITIONAL DATA WAS OBSERVED ON 04-22-2024 UTILIZING A CARLSON BRx7
DUAL FREQUENCY RECEIVER. THE GRID COORDINATES OF THE FIXED STATION(S) SHOWN WERE DERIVED USING A VRS NETWORK OF CORS STATIONS REFERENCED TO NAD 83
(2011) (EPOCH 2010), GEOID 12B.
POSITIONAL ACCURACY OF THE GPS VECTORS DOES NOT EXCEED: H 0.04’.
COMBINED GRID FACTOR: 0.99992369 CENTERED ON THE FIXED STATION.
ZONING:
MGA-1, MUNICIPAL GROWTH AREA
SETBACKS:
FRONT - ONE HUNDRED (100) FEET
REAR - SIXTY (60) FEET
SIDE - TWENTY (20) FEET
1. THE PURPOSE OF THIS PLAT IS TO CREATE 1 LOT.
2. PUBLIC WATER SUPPLY AVAILABLE UPON REQUEST TO NOLENSVILLE COLLEGE GROVE UTILITY DISTRICT.
3. PROPERTY IS LOCATED IN AN AREA OF MINIMAL FLOOD HAZARD PER FIRM MAPS FLOOD MAP NO. 47187C0240F DATED 09/29/2006, ZONE 'X', WILLIAMSON COUNTY
UNINCORPORATED AREAS, TN COMMUNITY # 470204.
4. THE SURVEYOR HAS NOT PHYSICALLY LOCATED THE UNDERGROUND UTILITIES. ABOVE GRADE AND UNDERGROUND UTILITIES SHOWN WERE TAKEN FROM VISIBLE
APPURTENANCES AT THE SITE, PUBLIC RECORD AND/OR MAPS PREPARED BY OTHERS. THE SURVEYOR MAKES NO GUARANTEE THAT THE UNDERGROUND UTILITIES SHOWN
COMPROMISE ALL SUCH UTILITIES IN THE AREA, EITHER IN SERVICE OR ABANDONED.
5.
THE SURVEYOR FURTHER DOES NOT WARRANT THAT THE UNDERGROUND UTILITIES SHOWN ARE IN THE EXACT LOCATION INDICATED. THEREFORE, RELIANCE UPON HE
TYPE, SIZE, AND LOCATION OF UTILITIES SHOWN SHOULD BE DONE SO WITH THIS CIRCUMSTANCE CONSIDERED. DETAILED VERIFICATION OF EXISTENCE, LOCATION AND
DEPTH SHOULD ALSO BE MADE PRIOR TO ANY DECISION RELATIVE THERETO IS MADE. AVAILABILITY AND COST OF SERVICE SHOULD BE CONFIRMED WITH THE
APPROPRIATE UTILITY COMPANY.
6.
TENNESSEE REQUIRES, PER THE UNDERGROUND UTILITY DAMAGE PREVENTION ACT THAT ANYONE WHO ENGAGES IN EXCAVATION MUST NOTIFY ALL KNOWN
UNDERGROUND UTILITY OWNERS NO LESS THAN (3) THREE NOR MORE THAN (10) WORKING DAYS PRIOR TO THE DATE OF THEIR INTENT TO EXCAVATE AND ALSO TO
AVOID ANY POSSIBLE HAZARD OR CONFLICT. CONTACT TENNESSEE ONE CALL AT 1-800-351-1111
7. THE SURVEYOR'S LIABILITY FOR THIS DOCUMENT SHALL BE LIMITED TO THE ORIGINAL PURCHASER AND DOES NOT EXTEND TO ANY UNNAMED PERSON OR ENTITIES
WITHOUT AN EXPRESSED RE-CERTIFICATION BY THE SURVEYOR WHOSE SIGNATURE APPEARS ON THIS SEAL.
8.
A TEN (10) FOOT EASEMENT ON EACH SIDE OF ALL REAR LOT LINES, TEN (10) FOOT EASEMENT ON EACH SIDE OF ALL SIDE LOT LINES, AND A TEN (10) FOOT EASEMENT
ALONG AND PARALLEL TO ALL RIGHT OF WAY, FOR DRAINAGE, UTILITY POLES, WIRES, CONDUITS, STORM AND SANITARY SEWERS, GAS, WATER, OR OTHER UTILITIES.
9. IN ACCORDANCE WITH THE FIRE PROTECTION STANDARDS OF ARTICLE 3.05 OF THE WILLIAMSON COUNTY SUBDIVISION REGULATIONS BUILDING ENVELOPES MUST BE
SPACED NO CLOSER THAN 200 FEET APART AND EITHER:
A.) SPRINKLER SYSTEMS SHALL BE PROVIDED IN ALL HABITABLE STRUCTURES; OR,
B.) ACCEPTABLE FIRE APPARATUS ACCESS SHALL BE PROVIDED FOR EACH STRUCTURE, INCLUDING THE FOLLOWING:
B1.) THE MAXIMUM DRIVEWAY GRADE (INCLUDING SHARED DRIVES) TO EACH
STRUCTURE SHALL NOT EXCEED 12 %;
B2.) IF THE LENGTH OF ANY DRIVEWAY (INCLUDING SHARED DRIVES) LEADING TO A HABITABLE STRUCTURE EXCEEDS 1,000 FEET, A TURNAROUND
AREA WITH A RADIUS OF AT LEAST 40 FEET SHALL BE PROVIDED EVERY 1,000 FEET ALONG THE DRIVEWAY FROM THE PUBLIC ROAD TO THE FURTHEST HABITABLE
STRUCTURE FROM THE PUBLIC ROAD;
B3.) THE MINIMUM WIDTH OF THE SHARED DRIVEWAY SHALL BE 16 FEET AND THE MINIMUM WIDTH OF THE INDIVIDUAL DRIVES BETWEEN THE
SHARED DRIVE AND THE HABITABLE STRUCTURES SHALL BE 12 FEET; AND
B4.) A LANDING AREA WITH A GRADE NO GREATER THAN 8 % SHALL BE PROVIDED NO FURTHER THAN 200 FEET FROM ALL HABITABLE STRUCTURES IN ORDER TO
STAGE FIREFIGHTING APPARATUS.
PRIVATE DRIVEWAY NOTATION
THIS IS A PRIVATE DRIVEWAY AND IS NOT A PUBLIC ROAD. WILLIAMSON
COUNTY DOES NOT HAVE RESPONSIBILITY FOR BUILDING OR
MAINTAINING THE PRIVATE DRIVEWAY. THE WILLIAMSON COUNTY
HIGHWAY COMMISSION MAY, AT ITS DISCRETION, AGREE TO ACCEPT
THIS PRIVATE DRIVEWAY AS A PUBLIC ROAD INTO THE COUNTY HIGHWAY
SYSTEM IF ALL PROPERTY OWNERS AGREE TO (1) PETITION THE
HIGHWAY COMMISSION FOR A PUBLIC ROAD AND (2) BUILD OR PAY FOR
UPGRADING THE PRIVATE DRIVEWAY TO COUNTY SPECIFICATIONS IN
EFFECT AT TIME OF REQUEST
COUNTY ENGINEER COUNTY ROAD SUPERINTENDENT
DATE
BY SIGNING BELOW, THE PROPERTY OWNER(S) OF ALL LOTS WITHIN THE BOUNDS OF THIS PLAT
ACKNOWLEDGE AWARENESS OF THE ABOVE PRIVATE DRIVEWAY NOTATION, AND UNDERSTAND
WILLIAMSON COUNTY DOES NOT HAVE RESPONISBILITY FOR BUILDING OR MAINTAINING THE
PRIVATE DRIVEWAY
DATE DEED BOOK & PAGE
OWNER SIGNATURE(S) TAX MAP & PARCEL NUMBER OF LOT
NATURAL RESOURCE PROTECTION NOTES (WATERWAY NATURAL AREA (W.N.A.))
1. ANY WATERWAY NATURAL AREA SHOWN HERON IS SUBJECT TO PROTECTIVE COVENANTS WHICH MAY BE FOUND IN THE LAND
RECORDS AND WHICH RESTRICT DISTURBANCE AND USE OF THESE AREAS.
2. WITHIN THE WATERWAY NATURAL AREA, THERE SHALL BE NO CLEARING, GRADING, CONSTRUCTION, OR DISTURBANCE OF
VEGETATION EXCEPT AS PERMITTED BY THE WILLIAMSON COUNTY ENGINEERING DEPARTMENT.
3. WATERWAY NATURAL AREAS (W.N.A.) EXIST ON ALL INTERMITTENT OR PERENNIAL STREAM WATERWAYS AS DEFINED IN THE
WILLIAMSON COUNTY STORM WATER MANAGEMENT REGULATIONS. FOR MORE INFORMATION OR ASSISTANCE IN APPLYING
THESE REGULATIONS, PLEASE CONTACT THE WILLIAMSON COUNTY ENGINEERING DEPARTMENT AT (615)790-5725.
NATURAL RESOURCE PROTECTION NOTES
1. STEEP SLOPES: THIS SITE HAS BEEN REVIEWED FOR THE PRESENCE OF A PROTECTED RESOURCE CONSISTING OF MODERATE STEEP SLOPES (15%-25%) AND VERY STEEP
SLOPES (EXCESS OF 25%). BASED ON THE TENNESSEE LIDAR MAPPING ONE-FOOT CONTOURS, THERE IS EVIDENCE OF MODERATE STEEP SLOPES ON LOT 201. THERE ARE
NO MODERATE STEEP SLOPES WITHIN THE BUILDING ENVELOPE OF LOT 201. THERE ARE NO VERY STEEP SLOPES INSIDE THE BUILDING ENVELOPE OF LOT 201.
2. SLIPPAGE SOILS: THIS SITE HAS BEEN REVIEWED FOR THE PRESENCE OF THE PROTECTED RESOURCE CONSISTING OF SLIPPAGE SOILS FOR LOT 201. THERE ARE NO
EVIDENCE OF SLIPPAGE SOILS BASED ON THE WILLIAMSON COUNTY SOIL SURVEY.
3. KARSTS FEATURES: THIS SITE HAS BEEN REVIEWED FOR THE PRESENCE OF THE PROTECTED RESOURCE CONSISTING OF KARSTS FEATURES FOR LOT 201. THERE IS NO
APPARENT EVIDENCE OF KARSTS TOPOGRAPHY WITHIN OR OUTSIDE THE BUILDING ENVELOPE. BASED ON APPLICANT'S VISUAL RECONNAISSANCE, LOT 201 IS ABSENT OF
KARSTS FEATURES.
4. HILLTOPS AND RIDGE TOPS: THIS SITE HAS BEEN REVIEWED FOR THE PRESENCE OF THE PROTECTED RESOURCE CONSISTING OF HILLTOPS AND RIDGE TOPS FOR LOT 201.
THERE ARE NO HILLTOPS OR RIDGETOPS WITHIN OR OUTSIDE THE BUILDING ENVELOPE. LOT 201 IS ABSENT OF HILLTOPS AND RIDGE TOPS.
5. WETLANDS: THIS SITE HAS BEEN REVIEWED FOR THE PRESENCE OF THE PROTECTED RESOURCE CONSISTING OF WETLANDS AS DETERMINED ON THE NATIONAL WETLANDS
INVENTORY MAPPER OF THE U.S. FISH AND WILDLIFE SERVICE FOR LOT 201. LOT 201 IS ABSENT OF WETLANDS.
6. LAND DISTURBANCE: NO LAND DISTURBING ACTIVITIES IN AREAS GREATER THAN 50% SLOPES. WHERE DRIVEWAYS AND/OR MINOR UTILITIES CROSS VERY STEP SLOPES
BETWEEN 25% & 50%, THE APPLICANT MUST SUBMIT A GEOTECHNICAL STUDY WITH FINDINGS SHOWING THAT DRIVEWAYS AND MINOR UTILITIES WILL NOT HAVE
SIGNIFICANT VISUAL, ENVIRONMENTAL, OR SAFETY IMPACTS, OR APPROPRIATE ENGINEERING OR OTHER MEASURES WILL BE TAKEN BY THE DEVELOPER TO SUBSTANTIALLY
MITIGATE ANY SUCH IMPACT AND IF NO ALTERNATIVE LOCATION FOR ACCESS OR MINOR UTILITIES IS FEASIBLE OR AVAILABLE.
OWNER #2 SIGNATURE DATE
SECTION 2 FINAL PLAT OF THE
ARTESIAN ACRES SUBDIVISION
JOHN BATEY
2015 ARTESIAN DRIVE
WILLIAMSON COUNTY, TENNESSEE
DESIGN
PLANNING
SURVEYING
CIVIL
A
CONSULTING ENGINEERS & LAND SURVEYORS
SPRING HILL, TN 37174
Fax: 615.523.1517
PH 615.481.3106
P.O. BOX 1636
Ahler & Associates, LLC
Sheet No.
Drawn By: Checked By:
Proj. No.:
File Name:
Date:
Date
Sheet.dwg
No. Revision Description
Sheet Title
1234567891011
A
B
C
D
E
F
G
H
I
1208 HIGHWAY 47E DICKSON, TN 37055
(615) 740-8777 (T) (615) 441-8776 (F)
Southern Consulting
Engineering Materials Testing Surveying
Environmental Services
4/21/2026
JHH JEA
4/21/26
ATTACHMENT 33-1
ATTACHMENT 33-2
Item 34—Page 1 of 1
Reviewer: OCW
Date: 5/14/2026
ITEM 34
FINAL PLAT REVIEW FOR KING’S CHAPEL SUBDIVISION, SECTION 16,
CONTAINING 1 LOT ON 0.78 ACRES LOCATED OFF MURFREESBORO ROAD IN
THE 5TH VOTING DISTRICT (1-2026-406).
Attachment 34-1 Preliminary Plat
34-2 Aerial Photograph
Area 0.78 acres
Lots 1
Zoning Rural Development–1 (RD-1)
Water Milcrofton Utility District
Sewer Superior Wastewater System
Development Option Planned Resource Conservation Development (PRCD)
Chapter 1101 Status Rural
File Number (1-2026-406)
A Preliminary Plat for this Section was approved at the November, 2024 meeting. The
applicant is now requesting Final Plat approval for the sixteenth (16 th) Section of the
development, which consists of one buildable lot and appro ximately half an acre (0.5) of
Open S pace. As the Section is internal and infrastructure has been installed , no
Landscaping Plan, Performance bond for water improvement, or a Performance Bond for
roads, drainage, and erosion control are required.
The Final Plat is consistent in layout with that depicted on the Preliminary Plat . Staff
recommends approval of the Final Plat with the following conditions:
1. The approved HOA documents shall addre ss the requirements of Section 17.11:
Gated Subdivisions and Section 17.12: Private Streets of the Zoning Ordinance .
The approved HOA documents must be recorded concurrently with the recording
of the Final Plat.
2. Per the recommendation of the County’s Wastewater Consultant, establishment of
a Performance Bond for the Wastewater Collecti on System in the amount of
$8,000;
3. Execution of performance agreements for the above referenced sureties; and
4. Submission of the approved Final Plat in .dwg format on recordable media based
on the Tennessee State Plane Coordinate System prior to signature and recording
of the plat.
Community
KINGS’ CHAPEL
Owner / Developer:
P.O. BOX 190
ASHBY COMMUNITIES HPH LLC
ARRINGTON, TN 37014
MAP 109- PARCEL 40.00 BOOK 9384, PG. 881
06
91
.SSE
E
Text truncated. Open the original for the full document.
Source: Williamson County website. First collected Nov 4, 2026.