RecordWell Data

Access Board of Appeals — Agenda

City of Clarksville · Montgomery County · Access Management Board of Appeals · meeting of Jun 17, 2026 · Agendas

Open the original document More from City of Clarksville

Text

Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.

Access Management Board of Appeals AGENDA DATE: June 17, 2026 LOCATION: Clarksville Street Dept. 199 10 th Street Clarksville, TN 37040 TIME: 4:00 P.M. I. CALL TO ORDER II. ANNOUNCE MEMBERS IN ATTENDANCE (VERIFY QUORUM) Jeff Henley Planning Commission Jeff@henleytaxcpa.com Wanda Smith Councilwoman Wanda.Smith@cityofclarksville.com Jack Frazier jack.frazier@charter.net Bryce Powers bryce@pb-llc.com Christian Black ` cblack@realtracs.com Syd Hedrick sydhedrick@bellsouth.net III . ADOPTION OF MINUTES - April 15, 2025 IV. COMMITTEE ACTION REQUIRED IV.A CASE # 2026-03 - Horshoecave and Calmet DESCRIPTION: The property owner is requesting two driveways on Horshoecave OWNER: Bill Mace EMAIL: jschmittou@billmacehomes.com ENGINEER: McKay & Burchett Company EMAIL: cmckay@mbcengineer.com IV. B CASE # 2026-04 - 100 Highland Bluff Way DESCRIPTION: The property owner is requesting one driveway on Highland Bluff Way OWNER: Elcan and Associates EMAIL: ROgburn@elcaninc.com ENGINEER: McKay & Burchett Company EMAIL: cburchett@mbcengineer.com VIII. ADJOURNMENT Motions Proposed: Chair Wanda Smith entertained a motion to accept the case as requested • Bryce Powers made a motion to approve the driveways with replating the existing plat • 2nd motion Jack Frazier • Vote 4-0 Chair Wanda Smith, Jack Frazier, Bryce Powers, and Christian Black approved the motion VI. ADJOURNMENT A motion to adjourn was entertained by Chair Wanda Smith, motion approved by Jack Frazier, and seconded by Byce Powers. The meeting was adjourned without objection at 4: 15 p.m. Chairperson Date 12''W 12''W XUM STS STRUCTURE?TC=508.00IE=503.85 HORSESHOE CAVE DRIVE(70' ROW) CALUMET DRIVE(50' ROW) LIFEPOINT CHURCHREC'D VOL. 2054, PG. 2038ZONED R-4 CALUMET DRIVE(50' ROW) SASASASASASASASA SASASASASASASA 50' MBSL 6''W 6''W 6''W 6''W 6''W 6''W 6''W 6''W W 8''W8''W8''W8''W8''W8''W8''W8''W8''W8''W8''W8''W8''W8''W8''W8''W8''W8''WHORSESHOE CAVE DRIVE(75' ROW)C81 S12° 38' 22"W 212.94' 6''W 6''W 6''W ////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////// //////////////////////////////////////////////////////////////////////////////////////////////////////// 1313 1112 88 VAN 79 10 11PROPOSED LOT LINE 15 13 60' 325' PROPOSED RETAIL BUILDING12,000 SFFFE: 514.0 PROPOSED RETAIL BUILDING15,600 SFFFE: 516.0 //////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////// OVERHEAD DOORS 14 14 10 27.8' 47.8' PROPOSED OFFICE 5,000 SFWAREHOUSE BUILDING 10,000 SFFFE: 516.0300' 50' 200' 60' 25' MBSL WILLIAM BELEWREC'D VOL. 2456, PG. 4894ZONED R-425' MBSL XXPROPOSED DUMPSTERPADS W/ 6' OPAQUE FENCETO DRAIN TO SEWER 50' MBSL 50' MBSL 36' 20' PUDE 20' PUDE 5' PUDE 5' PUDE 24' 24' MANHOLEIE IN:496.73IE OUT:496.63 MANHOLEIE IN:504.12IE OUT:498.23 SSSSSSSSSSSSSSSSSSSSSSSSSSSSSS PROPOSED DUMPSTER PADW/ 6' OPAQUE FENCE TODRAIN TO SEWER SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS SSSSSSS SSSSSSSSSSSSSSS SSSSSSSSSSSSSSSSSSSSSSSSSSSSS 506508510512 514 516 518 504 504 506 506 508 508 510 510 512 512514516518 504506508510 512 514 516 518 508 510 512 514 514516 516518 518 508510512514516518 WM WM 8 METER GANG VAULTW/ 8 (34") METERS 5 METER GANG VAULTW/ 5 (34") METERS WMWM WWWWWWW INSTALL:1 - 6 METER GANG VAULT W/ 6 (34") METERS1 - 7 METER GANG VAULT W/ 7 (34") METERSS77° 23' 40"E 369.83' N12° 38' 03"E 524.12' N77° 22' 50"W 344.79' L=39.26, R=25.00D=89°58'33", T=24.99CH=S57°37'46"W, 35.35' S12° 38' 22"W 499.22' 24' 24' 24' XX 10 6 8 XXXX SSSS PROPOSED 6"PVC SEWER LINE4" SEWERSERVICE, TYP. PROPOSED SIGN LOADING/UNLOADING LOADING/UNLOADING PROPOSED SIGN2 5' SIDEWALK 5' SIDEWALK 5' SIDEWALK 5' SIDEWALK 4" DUCTILEIRON PROPOSEDFIREHYDRANT 6''W 6''W 6''W 6''W 6''W 6''W 6''W6''W NSEW 1 inch = ft.GRAPHIC SCALE (IN FEET)0 402080 4040 ISSUED FOR:PERMITTINGBID PURPOSESCONSTRUCTION GENERAL NOTES:1. All utility locations based on location of utilities by local utility authorities and visiblefield location by others. There is no guarantee that no other utilities either public orprivate are not displayed on this survey.2. All site lighting shall be directed inward with shielded hoods. No light shall spill onadjacent property. 1545 Madison StreetClarksville, TN 37040Ph # 931-245-3095MACE HORSESHOE COMMERCIALPRELIMINARY SITE LAYOUTHORSESHOE CAVE DRIVE, CLARKSVILLEMONTGOMERY COUNTY, TENNESSEEMay 15, 2026SHEET: PRE. 1.01REVISIONSDATE COMMENTS DRAWN BY: K.COOKCHECKED BY: C. BURCHETTFILE - Z:\Projects\2026\0043-26(Mace Horseshoe CaveCommercial)\Mace Horseshoe CaveCommercial.dwg 5/15/26 GENERAL SITE INFORMATION:OWNER:WILLIAM BELEW JR1920 NEEDMORE ROADCLARKSVILLE, TN 37042DEVELOPER:BILL MACE HOMES1919 TINY TOWN RD. STE. 100CLARKSVILLE, TN 37042CURRENT ZONING: C-5CIVIL DISTRICT: 2ndDEED REF. #O.R.V. 2054, PG. 2038TAX MAP NO. 018 PARCEL NO. 16.00 (PORTION OF)TOTAL ACREAGE: 193,706 SF (4.45 ± ACRES)PROPOSED BUILDING COVERAGE: 42,600 SF (21.9%)PROPOSED USE: RETAIL 27,600 SFPROPOSED USED: WAREHOUSE 10,000 SFPROPOSED USED: OFFICE: 5,000 SFPROPOSED IMPERVIOUS AREA AND RATIO: 163,838 SF (84.5%)PROPOSED PARKING REQUIRED: 163RETAIL = 5 PER 1,000 SFREQUIRED: 138WAREHOUSE = 1 PER 1,000 SFREQUIRED: 10OFFICE = 3 PER 1,000 SFREQUIRED: 15PROPOSED PARKING PROVIDED: 194PROPOSED ADA PARKING PROVIDED: 7BUILDING HEIGHT: 50' MAXIMUM SITETINY TOWN RDHORSESHOE RD VICINITY MAP(NOT TO SCALE) CALUMET DR SANDPIPER DR BOUNDARY LINESITE LEGEND ROADWAY CENTERLINEGAS MAIN & SERVICE LINEWATER MAIN & SERVICE LINESANITARY SEWER MAIN & SERVICESTORM SEWER LINEELECTRIC LINE STREET LIGHTSANITARY SEWER MANHOLEPOWER POLEWATER VALVE STORM SEWER INLETELECTRICAL TRANSFORMERWATER METERFIRE HYDRANT ADJACENT PROPERTY LINE G W E ETELEPHONE BOXT PUDEMBSL EXISTING IRON PINPROPOSED IRON PIN FENCELINE XSTREAM LINESILT FENCE SFEXISTING CURBUNDERGROUND TELEPHONE TBENCHMARK SA PROPOSED WATER MAIN (SIZE TBD) WPROPOSED SANITARY SEWERSASA TREE LINE ^ ^ PROPOSED CONCRETEPROPOSED HEAVY DUTY PAVEMENTPROPOSED LIGHT DUTY PAVEMENT WM CASE # SR - 42 - 2026 APPEALS FOR VARIANCE APPELLANT/OWNER OR AGENT OF OWNER: APP/PERMIT NO.____________ ________________________________________ Email Address.___________________ AGENT_________________________________ MAP/PARCELNO._____________ The appellant hereby appeals from the decision of the Director of Streets denying its access permit quality permit application and/or approval of property development plans, said request being more particularly described as follows: The affected property is located at _______________________________ All specifications, plans and other supporting documents to include fifty dollar ($ 50.00) heretofore filed with the Director of Streets are incorporated herein by reference and made a part of this appeal. Said access permit application and/or property development plans was denied for the following reasons. The appellant hereby requests that the decision of the Director of Streets be set aside and the permit granted or the property development approved. Appellant would show that said request is justified for the following reasons: The requested variance is justified due to the unique configuration and operational requirements of this site. The proposed northern access on Highland Bluff Way is necessary to accommodate safe and efficient circulation around the building for customer vehicles, emergency vehicles, and regular semi-trailer deliveries serving the proposed Dollar Tree store. As shown on the site plan, the parcel is constrained by its size, shape, required landscape buffers, building setbacks, parking requirements, and the need to provide adequate truck maneuvering around the building. Relocating the access farther south to fully comply with the ordinance would significantly impair internal circulation and create operational challenges for delivery vehicles and emergency access. The requested relief is minimal. The proposed driveway is located approximately 50 feet from the edge of pavement of Tiny Town Road, and the variance represents only a modest deviation from the spacing requirement. Adequate sight distance is available for vehicles entering and exiting the site, and the proposed access will not create a traffic hazard. Additionally, Highland Bluff Way functions as a private travel easement serving a limited number of properties and has no significant future development potential. As a result, traffic volumes on Highland Bluff Way are expected to remain low, minimizing any impact associated with the reduced driveway spacing. Granting the variance will allow reasonable development of the property while maintaining safe access and circulation. The request is the minimum variance necessary to accommodate the site's constraints and operational requirements and will not be detrimental to public safety, adjacent properties, or the public welfare. COCO GPGPW ADJOINER BUILDINGNOT A PART OF SURVEY TINY TOWN ROAD(AKA STATE ROUTE 236)VARIABLE WIDTH PUBLIC RIGHT-OF-WAYVARIABLE WIDTH ASPHALT PAVEMENT HIGHLAND BLUFF WAYVARIABLE WIDTH PRIVATE RIGHT-OF-WAYVARIABLE WIDTH ASPHALT PAVEMENT R/W MB DYH TBM#1 TBM#2 GRAVEL CONCRETEACCESS ACCESS CI#1CI#2 CI#3 FO 24" CPPFL: 505.0' S C1 C2L1C3C4L2C5L3C6 TRAVEL EASEMENTPLAT BOOK N, PAGE 1439 20' PUDE EASEMENTPLAT BOOK N, PAGE 143 50' MBSLPLAT BOOK N, PAGE 143 9 9 SIGN EASEMENTPLAT BOOK N, PAGE 1439 10 APPROXIMATE LOCATIONPERMANENT UTILITY EASEMENTDEED BOOK 2349, PG. 736 CI#4 2.7'A 1.1' 0.5'B CONCRETE S 82°17'54" E 107.81'(M) N 79°55'34" W 53.40'(M) N 05°05'46" W 260.77'(M)N 05°05'27" W 260.78'(R) S 82°17'59" E 107.72'(R) N 79°59'09" W 53.47'(R) VACANT LANDLOT 1PLAT BOOK N, PAGE 14350,635 SQ.FT. ±1.162 ACRES ±APN:007 01109 00002007 311'± N 10°10'20" E 50.65'(M) S 82°17'16" E 183.83'(M)S 82°17'59" E 183.97'(CFR) N 10°16'12" E 50.65'(R) BASIS OF BEARING 10.0' 10' UTILITY AND DRAINAGE EASEMENTPLAT BOOK N, PG. 143 5' UTILITY AND DRAINAGE EASEMENTPLAT BOOK N, PG. 143 5' UTILITY AND DRAINAGE EASEMENTPLAT BOOK N, PG. 143 9 9 9 R/W323' ±CI#5 DOLLARTREE±11,600 SFFFE 523.012 9 91315 50' 15' LANDSCAPE BUFFER24' 10'4' 10'5.2' 36' 5'100.78'114.85' 522.1 522.8522.3 522.0 521.0 520.0 519.0518.0 520.0 514.0 515.5 523.5 519.0518.0517.0 517.5 516.0517.0 518.0 519.0520.0 15' LANDSCAPE BUFFER CLARKSVILLE, TN100 HIGHLAND BLUFFSCALE: 1:80' PREPARED DATE: 11/14/25REVISION DATE: 05/28/26DRAWN BY: JTJ NORTH SITE DATA SUMMARYArea Summary: Asphalt Paving: Yes UON Building: Parking Summary:Required: 58 Provided: 58 Building Setbacks:Front: 50'Side: 15'Rear: 25' Prepared for: Allowed Signage Description: TBC PROPOSEDRETAIL Building type: PEMB ___CMU ___Brace Framed ___ Provided Space Size: 9x18 Req. Space Size: tbc Required Signage: 212.75 SF Total Site Area: 1.16 Acres Notes: Total Space Leased - 11,600 SFCeiling Height (Sales Area) - 12'-0"Other ___Sprinklered - Allowed Signage SF: Storm Retention - TBCAverage __ 100 yr __ 500 yr __ Topo Challenges present Subdividion Req.: NoLandscape TBC Flood Zone - none (Fema) X

Source: City of Clarksville website. First collected Oct 18, 2026.