I. CALL TO ORDER
II. ANNOUNCE MEMBERS IN ATTENDANCE (VERIFY QUORUM) Jeff Henley Planning Commission
Jeff@henleytaxcpa.com
Wanda Smith Councilwoman
Wanda.Smith@cityofclarksville.com
Jack Frazier jack.frazier@charter.net Bryce Powers bryce@pb-llc.com Christian Black ` cblack@realtracs.com Syd Hedrick sydhedrick@bellsouth.net
III . ADOPTION OF MINUTES - April 15, 2025 IV. COMMITTEE ACTION REQUIRED IV.A CASE # 2026-03 - Horshoecave and Calmet DESCRIPTION: The property owner is requesting two driveways on Horshoecave OWNER: Bill Mace EMAIL: jschmittou@billmacehomes.com ENGINEER: McKay & Burchett Company EMAIL: cmckay@mbcengineer.com IV.
B
CASE # 2026-04 - 100 Highland Bluff Way DESCRIPTION: The property owner is requesting one driveway on Highland Bluff Way OWNER: Elcan and Associates EMAIL: ROgburn@elcaninc.com ENGINEER: McKay & Burchett Company EMAIL: cburchett@mbcengineer.com VIII. ADJOURNMENT
Motions Proposed: Chair Wanda Smith entertained a motion to accept the case as
requested
• Bryce Powers made a motion to approve the driveways with replating the
existing plat
• 2nd motion
Jack Frazier
• Vote 4-0
Chair Wanda Smith, Jack Frazier, Bryce Powers, and Christian Black
approved the motion
VI. ADJOURNMENT
A motion to adjourn was entertained by Chair Wanda Smith, motion approved by Jack Frazier, and
seconded
by Byce Powers. The meeting was adjourned without objection at 4: 15 p.m.
Chairperson Date
12''W
12''W
XUM STS STRUCTURE?TC=508.00IE=503.85
HORSESHOE CAVE DRIVE(70' ROW)
CALUMET DRIVE(50' ROW)
LIFEPOINT CHURCHREC'D VOL. 2054, PG. 2038ZONED R-4
CALUMET DRIVE(50' ROW)
SASASASASASASASA
SASASASASASASA
50' MBSL
6''W
6''W
6''W
6''W
6''W
6''W
6''W
6''W
W
8''W8''W8''W8''W8''W8''W8''W8''W8''W8''W8''W8''W8''W8''W8''W8''W8''W8''WHORSESHOE CAVE DRIVE(75' ROW)C81
S12° 38' 22"W 212.94'
6''W
6''W
6''W
//////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////
////////////////////////////////////////////////////////////////////////////////////////////////////////
1313
1112
88
VAN
79
10
11PROPOSED LOT LINE
15
13
60'
325'
PROPOSED RETAIL BUILDING12,000 SFFFE: 514.0
PROPOSED RETAIL BUILDING15,600 SFFFE: 516.0
////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////
OVERHEAD DOORS
14
14
10
27.8'
47.8'
PROPOSED OFFICE 5,000 SFWAREHOUSE BUILDING 10,000 SFFFE: 516.0300'
50'
200'
60'
25' MBSL
WILLIAM BELEWREC'D VOL. 2456, PG. 4894ZONED R-425' MBSL
XXPROPOSED DUMPSTERPADS W/ 6' OPAQUE FENCETO DRAIN TO SEWER
50' MBSL
50' MBSL
36'
20' PUDE
20' PUDE
5' PUDE
5' PUDE
24'
24' MANHOLEIE IN:496.73IE OUT:496.63
MANHOLEIE IN:504.12IE OUT:498.23
SSSSSSSSSSSSSSSSSSSSSSSSSSSSSS
PROPOSED DUMPSTER PADW/ 6' OPAQUE FENCE TODRAIN TO SEWER
SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS
SSSSSSS
SSSSSSSSSSSSSSS
SSSSSSSSSSSSSSSSSSSSSSSSSSSSS
506508510512
514
516
518
504
504
506
506
508
508
510
510
512
512514516518
504506508510
512
514 516
518
508 510 512
514
514516 516518 518
508510512514516518
WM
WM
8 METER GANG VAULTW/ 8 (34") METERS
5 METER GANG VAULTW/ 5 (34") METERS
WMWM
WWWWWWW
INSTALL:1 - 6 METER GANG VAULT W/ 6 (34") METERS1 - 7 METER GANG VAULT W/ 7 (34") METERSS77° 23' 40"E 369.83'
N12° 38' 03"E 524.12'
N77° 22' 50"W 344.79'
L=39.26, R=25.00D=89°58'33", T=24.99CH=S57°37'46"W, 35.35'
S12° 38' 22"W 499.22'
24'
24'
24'
XX
10
6 8
XXXX
SSSS
PROPOSED 6"PVC SEWER LINE4" SEWERSERVICE, TYP.
PROPOSED SIGN
LOADING/UNLOADING
LOADING/UNLOADING
PROPOSED SIGN2
5' SIDEWALK
5' SIDEWALK
5' SIDEWALK
5' SIDEWALK
4" DUCTILEIRON
PROPOSEDFIREHYDRANT
6''W
6''W
6''W
6''W
6''W
6''W
6''W6''W
NSEW
1 inch = ft.GRAPHIC SCALE (IN FEET)0 402080 4040
ISSUED FOR:PERMITTINGBID PURPOSESCONSTRUCTION
GENERAL NOTES:1. All utility locations based on location of utilities by local utility authorities and visiblefield location by others. There is no guarantee that no other utilities either public orprivate are not displayed on this survey.2. All site lighting shall be directed inward with shielded hoods. No light shall spill onadjacent property.
1545 Madison StreetClarksville, TN 37040Ph # 931-245-3095MACE HORSESHOE COMMERCIALPRELIMINARY SITE LAYOUTHORSESHOE CAVE DRIVE, CLARKSVILLEMONTGOMERY COUNTY, TENNESSEEMay 15, 2026SHEET: PRE. 1.01REVISIONSDATE COMMENTS
DRAWN BY: K.COOKCHECKED BY: C. BURCHETTFILE - Z:\Projects\2026\0043-26(Mace Horseshoe CaveCommercial)\Mace Horseshoe CaveCommercial.dwg
5/15/26
GENERAL SITE INFORMATION:OWNER:WILLIAM BELEW JR1920 NEEDMORE ROADCLARKSVILLE, TN 37042DEVELOPER:BILL MACE HOMES1919 TINY TOWN RD. STE. 100CLARKSVILLE, TN 37042CURRENT ZONING: C-5CIVIL DISTRICT: 2ndDEED REF. #O.R.V. 2054, PG. 2038TAX MAP NO. 018 PARCEL NO. 16.00 (PORTION OF)TOTAL ACREAGE: 193,706 SF (4.45 ± ACRES)PROPOSED BUILDING COVERAGE: 42,600 SF (21.9%)PROPOSED USE: RETAIL 27,600 SFPROPOSED USED: WAREHOUSE 10,000 SFPROPOSED USED: OFFICE: 5,000 SFPROPOSED IMPERVIOUS AREA AND RATIO: 163,838 SF (84.5%)PROPOSED PARKING REQUIRED: 163RETAIL = 5 PER 1,000 SFREQUIRED: 138WAREHOUSE = 1 PER 1,000 SFREQUIRED: 10OFFICE = 3 PER 1,000 SFREQUIRED: 15PROPOSED PARKING PROVIDED: 194PROPOSED ADA PARKING PROVIDED: 7BUILDING HEIGHT: 50' MAXIMUM
SITETINY TOWN RDHORSESHOE RD
VICINITY MAP(NOT TO SCALE)
CALUMET DR
SANDPIPER DR
BOUNDARY LINESITE LEGEND
ROADWAY CENTERLINEGAS MAIN & SERVICE LINEWATER MAIN & SERVICE LINESANITARY SEWER MAIN & SERVICESTORM SEWER LINEELECTRIC LINE
STREET LIGHTSANITARY SEWER MANHOLEPOWER POLEWATER VALVE
STORM SEWER INLETELECTRICAL TRANSFORMERWATER METERFIRE HYDRANT
ADJACENT PROPERTY LINE
G W E
ETELEPHONE BOXT
PUDEMBSL
EXISTING IRON PINPROPOSED IRON PIN
FENCELINE XSTREAM LINESILT FENCE
SFEXISTING CURBUNDERGROUND TELEPHONE TBENCHMARK
SA
PROPOSED WATER MAIN (SIZE TBD) WPROPOSED SANITARY SEWERSASA
TREE LINE ^ ^
PROPOSED CONCRETEPROPOSED HEAVY DUTY PAVEMENTPROPOSED LIGHT DUTY PAVEMENT
WM
CASE # SR - 42 - 2026
APPEALS FOR VARIANCE
APPELLANT/OWNER OR AGENT OF OWNER: APP/PERMIT NO.____________
________________________________________ Email Address.___________________
AGENT_________________________________ MAP/PARCELNO._____________
The appellant hereby appeals from the decision of the Director of
Streets denying its access permit quality permit application and/or approval
of property development plans, said request being more particularly
described as follows:
The affected property is located at _______________________________
All specifications, plans and other supporting documents to include fifty
dollar ($ 50.00) heretofore filed with the Director of Streets are incorporated
herein by reference and made a part of this appeal.
Said access permit application and/or property development plans was
denied for the following reasons.
The appellant hereby requests that the decision of the Director of Streets be
set aside and the permit granted or the property development approved.
Appellant would show that said request is justified for the following
reasons:
The requested variance is justified due to the unique configuration and operational
requirements of this site. The proposed northern access on Highland Bluff Way is
necessary to accommodate safe and efficient circulation around the building for customer
vehicles, emergency vehicles, and regular semi-trailer deliveries serving the proposed
Dollar Tree store.
As shown on the site plan, the parcel is constrained by its size, shape, required landscape
buffers, building setbacks, parking requirements, and the need to provide adequate truck
maneuvering around the building. Relocating the access farther south to fully comply with
the ordinance would significantly impair internal circulation and create operational
challenges for delivery vehicles and emergency access.
The requested relief is minimal. The proposed driveway is located approximately 50 feet
from the edge of pavement of Tiny Town Road, and the variance represents only a modest
deviation from the spacing requirement. Adequate sight distance is available for vehicles
entering and exiting the site, and the proposed access will not create a traffic hazard.
Additionally, Highland Bluff Way functions as a private travel easement serving a limited
number of properties and has no significant future development potential. As a result,
traffic volumes on Highland Bluff Way are expected to remain low, minimizing any impact
associated with the reduced driveway spacing.
Granting the variance will allow reasonable development of the property while maintaining
safe access and circulation. The request is the minimum variance necessary to
accommodate the site's constraints and operational requirements and will not be
detrimental to public safety, adjacent properties, or the public welfare.
COCO
GPGPW
ADJOINER BUILDINGNOT A PART OF SURVEY
TINY TOWN ROAD(AKA STATE ROUTE 236)VARIABLE WIDTH PUBLIC RIGHT-OF-WAYVARIABLE WIDTH ASPHALT PAVEMENT
HIGHLAND BLUFF WAYVARIABLE WIDTH PRIVATE RIGHT-OF-WAYVARIABLE WIDTH ASPHALT PAVEMENT
R/W
MB
DYH
TBM#1
TBM#2
GRAVEL
CONCRETEACCESS
ACCESS
CI#1CI#2
CI#3
FO
24" CPPFL: 505.0'
S
C1
C2L1C3C4L2C5L3C6
TRAVEL EASEMENTPLAT BOOK N, PAGE 1439
20' PUDE EASEMENTPLAT BOOK N, PAGE 143
50' MBSLPLAT BOOK N, PAGE 143
9
9
SIGN EASEMENTPLAT BOOK N, PAGE 1439
10 APPROXIMATE LOCATIONPERMANENT UTILITY EASEMENTDEED BOOK 2349, PG. 736 CI#4
2.7'A
1.1'
0.5'B
CONCRETE
S 82°17'54" E 107.81'(M)
N 79°55'34" W 53.40'(M)
N 05°05'46" W 260.77'(M)N 05°05'27" W 260.78'(R)
S 82°17'59" E 107.72'(R)
N 79°59'09" W 53.47'(R)
VACANT LANDLOT 1PLAT BOOK N, PAGE 14350,635 SQ.FT. ±1.162 ACRES ±APN:007 01109 00002007
311'±
N 10°10'20" E 50.65'(M)
S 82°17'16" E 183.83'(M)S 82°17'59" E 183.97'(CFR)
N 10°16'12" E 50.65'(R)
BASIS OF BEARING
10.0'
10' UTILITY AND DRAINAGE EASEMENTPLAT BOOK N, PG. 143
5' UTILITY AND DRAINAGE EASEMENTPLAT BOOK N, PG. 143
5' UTILITY AND DRAINAGE EASEMENTPLAT BOOK N, PG. 143
9
9
9
R/W323' ±CI#5
DOLLARTREE±11,600 SFFFE 523.012
9
91315
50'
15' LANDSCAPE BUFFER24'
10'4'
10'5.2' 36'
5'100.78'114.85'
522.1
522.8522.3
522.0
521.0
520.0
519.0518.0
520.0
514.0
515.5
523.5
519.0518.0517.0
517.5
516.0517.0
518.0
519.0520.0
15' LANDSCAPE BUFFER
CLARKSVILLE, TN100 HIGHLAND BLUFFSCALE: 1:80'
PREPARED DATE: 11/14/25REVISION DATE: 05/28/26DRAWN BY: JTJ
NORTH
SITE DATA SUMMARYArea Summary:
Asphalt Paving: Yes UON
Building:
Parking Summary:Required: 58 Provided: 58
Building Setbacks:Front: 50'Side: 15'Rear: 25'
Prepared for:
Allowed Signage Description: TBC
PROPOSEDRETAIL
Building type: PEMB ___CMU ___Brace Framed ___
Provided Space Size: 9x18 Req. Space Size: tbc
Required Signage: 212.75 SF
Total Site Area: 1.16 Acres
Notes:
Total Space Leased - 11,600 SFCeiling Height (Sales Area) - 12'-0"Other ___Sprinklered -
Allowed Signage SF:
Storm Retention - TBCAverage __ 100 yr __ 500 yr __ Topo Challenges present
Subdividion Req.: NoLandscape TBC
Flood Zone - none (Fema)
X
Source: City of Clarksville website. First collected Oct 18, 2026.